HomeMy WebLinkAbout16100 Plantation Lakes Cir BLDG 16 - 99-000759 (PLANTATION LAKES) (NEW APT BLDG) (A)-P Qc C �T
ZONE DATE
CONTRACTOR jO Ate Lk (ym-4 . �—
ADDRESS 5-55 S CrZ r3 --\r), rvimcE
PHONE #
LOCATION
OWNER
PHONE #
PLUMBING CONTRACTOR
ADDRESS
PHONE #
C�
PERMIT #
JOB �llef
COST $
FEE
STATE NO.
FEE $L(-)
ELECTRICAL CONTRACTOR �� � 5-z.,`L A 6-1Q (5eX FEE $ U ' �
I_"70T;Z*&9
PHONE #
MECHANICAL CONTRACTOR
ADDRESS
PHONE #
MISCELLANEOUS CONTRACTOR
ADDRESS
SEPTIC TANK PERMIT NO.
SOIL TEST REQUIREMENTS (�}
FINISHED FLOOR
ELEVATION REQUIREMENTS �)
ARCHITECTURAL APPROVAL
DATE:
FEE $��0
SUBDIVISION:
LOT NO.
BLOCK:
SECTION:
SQUARE FEET:
MODEL:
OCCUPANCY CLASS:
INSPECTIONS
TYPE DATE OK REJECT BY
FEE $ ENERGY SECT.
CERTIFICATE OF OCCUPANCY
ISSUED # v DATE:
FINAL DATE 1\0 —
EPI:
S Y M B 0 L L E S E N D
LETTER
A
SYMBOL
DESCRIPTION
PART NUMBER
OUTLET BOX
FRCP
FIRE ALARM CONTROL PANEL (FACP)
SEE SPECIFICATION SHEET
PROVIDED BY ALERT SECURITY
FAA.
FIRE ALARM SYSTEM ANNUN. (FAAP)
SEE SPECIFICATION SHEET
4" SQUARE w/SINGLE GANt, RING
HORN/STROBE
SEE SPECIFICATION SHEET
4" 3QUARE'x 2-1/85" DEEP BOX
0)
STROBE ^_
SEE SPECIFICATION SHEET
4" SQUARE x 2-1/8" DEEP BOX
L. j
MANUAL STATION
SEE SPECIFICATION SHEET
4" SQUARE w/SINGLE GANG RING
SPRINKLER WATER FLOW SWITCH
BY OTHERS
FLEX 'TO DEVICE FROM J --BOX
c
SPRINKLER TAMPER SWITCH
BY OTHERS
T R
FLEX TO DEVICE FROM ,J --BOX.
`C'
0
JUNc-riON E30X
_
BY OTHERS
4" SQUARE UNLESS NOTED
E
END--OF-LINE DEVICE
SEE SPECIFICATION 5h[FEE'T
PROVIDED BY ALERT SECURITY
L
PHOTOELECTRIC SMOKE DETECTOR/BASE
SEE SPECIFICATION SHEET
4' OCTAGON
L1
ROOM MINI -HORN
SEE. SPECIFICATION SHEET �
4„ SO DARE by/SINGLE GANG RING
2"70NE LEGEND
DESCRIPTION
FLOW SWITCH -RISER
TAMPER SWITCH-R]SER
SMOKE DETECTOR -FRCP
ALL PULL STATIONS
ZONE - NUMBER
2
3
4
W I R 1.... L.. 1.... G E N D "HARD WI E"
LETTER
A
DESdOlPTION
#16/2 C74D. SOLID RED FPL T(PE
USE
NOTIFICATION CIRCUIT
B
#14/2 CONE), SOLID BLUE FPL TYPE
24VOC POWER CIRCUIT
G
�E
#18/2 GOND. SOLID RED - FPL TYPE
_E
#18/2 GOND. SOLID RED-- FPL T`r`p
MANUAL •-- INITIATION CIRCUIT
T
AUTOMATIC INITIATION CIRCUIT
f
rEVISIONS W�C�ATE � \�
rDRAINN: SEC
CHECKED: PAL
€
MATE: 5 --- 25_-99
SCALE: -1/8"=V-O"
JOB NO.
SHEET
FA
BUILDING TYPE 1
1 ST FLOOR
1 OF 3 SHEETS
V J
I�
t
0)
t ,
LL.J_
00
I
Qo
V)
Ld
`C'
0
E
E
o
L
LL..
L1
Lli�
Fr
W
<
C1..
00
_Y1
rQ0
I,
<
<
0
z
<
r�
rDRAINN: SEC
CHECKED: PAL
€
MATE: 5 --- 25_-99
SCALE: -1/8"=V-O"
JOB NO.
SHEET
FA
BUILDING TYPE 1
1 ST FLOOR
1 OF 3 SHEETS
V J
I�
t ,
Cl.
L1
Lli�
Fr
>
u?
_Y1
a
I,
<
<
z
<
w
I EL
rDRAINN: SEC
CHECKED: PAL
€
MATE: 5 --- 25_-99
SCALE: -1/8"=V-O"
JOB NO.
SHEET
FA
BUILDING TYPE 1
1 ST FLOOR
1 OF 3 SHEETS
- - -- --------------
S Y M B 0 L L E G E N D
SYMBOL DESCRIPTION PART NUMBER OUTLET BOX'
Eqlp FIRE ALARM CONTROL PANEL (FACP) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY
E� FIRE ALARM SYSTEM ANNUN, (FAAP) SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING W I R E L E G E N D "HARD WIRE"
El HORN/STROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX
---------------- LETTER DESCRIPTION USE
,0' STROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX A #16/2 COND. SOLID RED FPL TYPE NOTIFICATION CIRCUIT
MANUAL STATION SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG PING #14/2 COND. SOLID BLUE FPL TYPE 24VOC POWER CIRCUIT
SPRINKLER WATER FLOW SWITCH BY OTHERS FLEX TO DEVICE FROM J -BOX D # 18/2 COND. SOLID RED FPL T�PE MANUAL - INITIATION CIRCUIT
#18 2 COND. SOLID RED- FPL TYPE AUTOMAI'IC INITIATION CIRCUIT
SPRINKLER 'TAMPER SWIL r C- H BY OTHERS FLEX TO DEVICE FROM J -BOX
-- ---- ----- - ----- -
JUNCTION BOX BY OTHERS 4" SQUARE UNLESS NOTED
END -OF -LINE DEVICE SEE SPECIFICAI'ION SHEET PROVIDED BY ALERT SECURITY
op- PHOTOELECTRIC SMOKE DETECTOR/BASE SEE SPECIFICATION SHEET 4" OCTAGON
ROOM MINI -HORN SEE SPECIFICAfION SHEET 4" SOUARE w/SINGLE GANG RING
. . . . . . . . ....
.......... . ...............................
....................... .... ................. ................. ... . . . . . . . . . . . . . . . . . . . . . . . . . ...... ......... ......................
. .. ....... ..... ............................................... .
. ............. ..............
. ..... ............ ............. ...................... ...... ....... ....... ................. ................ . ..... .
...... ......
. ........... ...... ..........
..........
......................
...........
91T
1ID, 17 . ................... i.
•n M
U-2
......... .........
........... .......... ..............
....... ......
D, "I
N
........ ......... ...... ........
U Al
... .........
.....................
........... . .... .. .
.............
....................
... . ... ...............
.....................................................
...................
�llv
. ......... ........... ...........
71 H-1
c. ......
Z4-11
.............
-T . .....
. ..........
di - -2 V
tr i �llv/
N,
a
............ ..............
............
0
At
) �IFT ZA _IN ..E. ,€# .
...........................
.....�......
.................... ....... .... ..E. E I ..........I ...................I .................. ............. ............... ..... ................ ............ ............ I ...............
Ea,
----------------
.........
..............
A
.. ........... . [� ......... IE
III
2 t"'. k�l
ii Im , f � 0-1 - -..ff' - _-, .11 .. ... ..
.......... ............ .......... .. I . ....... ..................... --- - ---- ...
LI T -ch E A Y3-H�Tll
..............
hiki!g
•.......... �S-
......................
...................
........................................ ................................ ............................. ............................ .......... ................ .............................
p � - FL, I
DAT_H HT
........... .......................
.... . ..........
..........
x
.................................... . ..........
............
A, T ...................... ...
t�.
'`
............................
........................ 0.,ki .....................
...................
..................
..... ..........
Fil
14 .................. ell.
.................. ...................
Z4-10
X
/p A�l
0
...............
...................
...........
. ...................... ............
.............. ........ ...... . ...........
0.1
J.
. . ...... .............. ........ .............
......... ......... ........ .........
�L �T
......... .........
...........
ZcMll
--j
............... ................................ ........... .. .......... ................ ...............
L .....................................................
.....................................................
A.
p
Fl E ALARM PLAN
..... .......
Lf}
.. .........
ji
. ..... BLDG TYPE I t.
. .. ......... ...
(9 1
100R SCALE:= 'I
. .... 2ND F
. ..... ......
W
ri ---- ii
L -------- i
............................
...................... ..............
..... ..... ..
rR EV I S, I n- NS DATE
PERMIT =-�E-C 5-25-99
Do
L5 rr) Q0
< CD
cr�
C) x
LL -
BPI CD
<
n 00
71 uj
r
Z Q0
o
N
0
LJ DRAWN: SEC
CHECKED: PAL
DATE: 5-25-99
SCALE: 1 3 -C
JOB NO.
SHEET
FA
BUILDING TYPE 'I
2ND FLOOR
2 OF 3 SHEETS
LL
Do
L5 rr) Q0
< CD
cr�
C) x
LL -
BPI CD
<
n 00
71 uj
r
Z Q0
o
N
0
LJ DRAWN: SEC
CHECKED: PAL
DATE: 5-25-99
SCALE: 1 3 -C
JOB NO.
SHEET
FA
BUILDING TYPE 'I
2ND FLOOR
2 OF 3 SHEETS
LL
LJ DRAWN: SEC
CHECKED: PAL
DATE: 5-25-99
SCALE: 1 3 -C
JOB NO.
SHEET
FA
BUILDING TYPE 'I
2ND FLOOR
2 OF 3 SHEETS
LL
LL
R\D F L 0 0 R
GENERAL NOTESS
1.
ALL WIRING MUST CONFORM WITH NEC ARTICLE 760 AND LOCAL
CODES. ALL, EQUIPMENT SHALL. BE UL LISTED. ALI DEVICES SHALL
BE COMPATIBLE WITH THE CONTROL PANELS.
2.
ALL INSTALLATION MATERIAL SUCH AS CONDUIT FITTINGS, BOXES,
HANC;EI•�ZS ETC. ARE NOT SUPPLIED BY ALERT SECURITY INC.
3.
ALL INTIATING AND INDICATING CIRCUITS MUST BE SUPERVISED.
4.
CIRCUIT POLARITY MUST BE OBSERVED.
5.
WIRE RUNS ARE SHOWN DIAGRAMMATICALLY, EXACT LOCATION OF
ALL EQUIPMENT TO BE DETERMINED IN THE FIELD, BUT SHALL
CONFORM WITH BASIC LAYOUT AS SHOWN ON DRAWINGS TO
PREVENT CIRCUIT OVERLOAD.
6.
MINIMUM CONDUIT SIZE WILL BE 3/4". CONDUIT SHALL BE NO
MORE THAN 40% FILLED.
7. DO NOT MARK ID NUMBERS ON DEVICES. LABEL BASE ONLY.
8, FAN SHUTDOWN RELAYS MUST BE LOCATED WITHIN 3` OF STARTER
COIL. PER NFPA 72.
9. THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO FLOWER
ANY UNAUTHORIZED EXTERNAL DEVICE.
10. DAMPER MOTOR AND FAN SHUTDWON (IF ANY) ARE TO BE COORDINATED
IN FIELD WITH HVAC CONTRACTOR,
11. ALL SURGE/TRANSIENT SUPRESSORS MUST BE CONNECTED TO APPROVED
BLDG. GROUND.
12, 120 VAC POWER REQUIREMENTS FOR FIRE ALARM CONTROL PANEL AND FIRE
.ALARM SYSTEM RELATED EQUIPMENT OR DEVICES USED IN THIS PROJECT
IS NOT THE RESPONSIBILITY OF ALERT SECURITY INC.
13. DG NOT APPLY 120 VAC POWER TO CONTROL PANEL UNTIL A ALERT
SECURITY INC. SERVICE TECNICIAN HAS INSPECTED ALL SYSTEM WIRING
CONNECTIONS AND HAS APPROVED THE SYSTEM TO BE TURNED ON,
r--------- PLASTIC GRCMMET
ALARM
A/STROBE
IRE ALARM
MANUAL
STATION
FLOOR
80"
I N S TA E. EAT I �� j N D E TA I C...._
MANIUAL clSTA...I._ION AND H��RN % ---7-)'TR�)P�E
TON. T. S. TO
120 FIELD
VAC DEVICES
PANEL MOUNTING DETAIL
M.S.
IN
rRE�f-,1
-.XPi. NS DALE
ERMlT r 5-25-99 I
DRAWN: SEC
CHECKED: PAL
DATE: 5-25-99
SCALE: 1/8"=l' -Q"
JOB NO.
SHEET
FA
BUILDING T'A'PE 1
3RD FLOOR
3 OF 3 SHEETS
))
W
CF)
00
c�
�I
!
L� J
IOW
r`
Ld
<7;
x
1
<
0
7
7
Lt I
t0
CD
-)G
L..LJI
0
n
00
I
z
c
cj'
Lei
�t-
CCS
cp
t\1
r
0
v"
cw�
DRAWN: SEC
CHECKED: PAL
DATE: 5-25-99
SCALE: 1/8"=l' -Q"
JOB NO.
SHEET
FA
BUILDING T'A'PE 1
3RD FLOOR
3 OF 3 SHEETS
))
W
<
w
0
L..LJI
0
LLJ
0
v"
cw�
E
DRAWN: SEC
CHECKED: PAL
DATE: 5-25-99
SCALE: 1/8"=l' -Q"
JOB NO.
SHEET
FA
BUILDING T'A'PE 1
3RD FLOOR
3 OF 3 SHEETS
))