Loading...
HomeMy WebLinkAbout200-250 W Lake Mary Blvd - BC00-001635 (RETAIL SHELL) DOCUMENTS (2)0fl ZONE DATE � �` bo CONTRACTOR��^v` ADDRESS PHONE #0vv\�+ LOCATIONco ��� , OWNER ADDRESS 'S c)(J / PHONE # u�` Z I l �%✓ ��%i�i'1l .� PLUMBING CONTRACTOR „ ADDRESS PHONE # ELECTRICAL CONTRACTOR OU ADDRESS PHONE # ��t�p� MECHANICAL CONTRACTOR r li ADDRESS PHONE.# MISCELLANEOUS CONTRACTOR ADDRESS SEPTIC TANK PERMIT NO. SOIL TEST REQUIREMENTS (_�) FINISHED FLOOR ELEVATION REQUIREMENTS (�_) ARCHITECTURAL APPROVAL DATE: PERMIT # OL fn -�� JOB r%sCl COST $ FEE $ STATE NO, FEE $ FEE $ IC) - FEE $ SUBDIVISION: LOT NO. BLOCK: SECTION: SQUARE FEET: MODEL: OCCUPANCY CLASS: INSPECTIONS [--TYPE DATE OK REJECT BY FEE $ ENERGY SECT CERTIFICATE OF OCCUPANCY ISSUED # FINAL DATE DATE: EPI: CITY OF SANFORD FIRE DEPARTMENT" 300 N. Park Ave. Sanford, FL 32771 (407) 302-2520 (407) 330-5677 FAX Plans Review Sheet Date: April 21, 2000 Business Address: 200/250 W. Lake Mary Blvd. Occ. Ch. #24 (New Mercantile) Business Name: Boulevard Plaza Ph. (407) 323-1333; (Larry Wheeler; Superintendent). Contractor: Life Safety Inc. Ph. (334) 864-8899 Reviewed [ ] Reviewed with eommeW x Rejected [ Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner �--� Comment: • All under groundwork to fire hydrants and fire mains require contractor to hold a Class #1 or Class #5 liecence. • Underground work on fire lines will be verified in thefield prior to ground cover, with a visual inspection. • Plans show six (6) rre hydrants; all hydrants shall meet N.F.P.A. #291,color codes. • Four -inch (40 storz hose connection required in lue of two and half inch hose connection. Fire Protection Systems: Two hour above hydro required on all sprinkler work. A ijlj J-) I 1.i ti I I U' y -D 1 Wj ti I J_;� I L'i I y i_jj'j Lj_ I y v I 1I -J- v4 'L I i -i J..0 r 11 .4 &a J_i M_38_ T4 SYSTEM 142" TO SYSTEM C ,,,—GROOVE COUPLI NG ELE SPRINKLER MAIN RTB� Ea GROOVE CAP FLUSHING Q-0.N.NECTION N.T.S, USE AT ENDS OF ALL MAINS 2" "N DRAW. 4" GR. EASY RISER 3, BUTTERFLY VALVE iT14 TA&PF,'R:' SWITCH— 6x8 PLAN= RED. 6,5 PSI RESIDUAL THIS PROJECT IS NOT LOCATED IN A FLOOD ZOK REQUIRING 1300 GFM FLOW QONSIDERATION IN THE DESIGN OF THE -SPRINIKLER SYSTEM, WATER TEST BY SANFORD FI -RE DEPT H A (PETE) T.UCKEIR FIRE} ALL SPRINKLERS, VALVES, FITTINGS A I NI) EQUIPMENT TO COMPLY WITH- SPEC'S. FIRE PROTECTION INSPECTOR INTERIOR PIPING d' AND LARGER TO BE SCHEDULE 10 WITH GROOVE AND WELD FITTINGS - MARCH 17) 2000 1' PIPE TO BE SCHEDULE 40 WITH SCREW FITTINGS. UNDERGROUND IiIPING TO BE CEMENT LINED DIUCTILE IRON TO 5' OUT, ALL UNDERGROUND BENDS TO BE THRUST BLOCKED. ALL UNDERGROUND PIPING TO BE FLUSHED BEFORE CONNECTION TO SYSTEM, L.S,I, TO WARRANTEE & CERTIFY ONLY WORK ]PERFORMED BY L,S.1, ALL PIPE LENGTHS ARE SHOWN CL TO 1� ALL WALLS BETWEEN EXPOSED STRUCTURE. AND SUSPENDED CEILING AREAS TO BE: FULL HEIGHT ALL SSP, SSU & 'DRY HEADS TO BE VIKING MODEL- M, INT, LEVEL HEADS TO BE VIKING -C-1, Flp"E TOP SYMBIX OTY, tE,.�rlit Fm PENWK UPRIGHT 161 Lx�) C\2 go%"'qp� 2" "N DRAW. 4" GR. EASY RISER 3, BUTTERFLY VALVE iT14 TA&PF,'R:' SWITCH— 6x8 PLAN= RED. 6,5 PSI RESIDUAL THIS PROJECT IS NOT LOCATED IN A FLOOD ZOK REQUIRING 1300 GFM FLOW QONSIDERATION IN THE DESIGN OF THE -SPRINIKLER SYSTEM, WATER TEST BY SANFORD FI -RE DEPT H A (PETE) T.UCKEIR FIRE} ALL SPRINKLERS, VALVES, FITTINGS A I NI) EQUIPMENT TO COMPLY WITH- SPEC'S. FIRE PROTECTION INSPECTOR INTERIOR PIPING d' AND LARGER TO BE SCHEDULE 10 WITH GROOVE AND WELD FITTINGS - MARCH 17) 2000 1' PIPE TO BE SCHEDULE 40 WITH SCREW FITTINGS. UNDERGROUND IiIPING TO BE CEMENT LINED DIUCTILE IRON TO 5' OUT, ALL UNDERGROUND BENDS TO BE THRUST BLOCKED. ALL UNDERGROUND PIPING TO BE FLUSHED BEFORE CONNECTION TO SYSTEM, L.S,I, TO WARRANTEE & CERTIFY ONLY WORK ]PERFORMED BY L,S.1, ALL PIPE LENGTHS ARE SHOWN CL TO 1� ALL WALLS BETWEEN EXPOSED STRUCTURE. AND SUSPENDED CEILING AREAS TO BE: FULL HEIGHT ALL SSP, SSU & 'DRY HEADS TO BE VIKING MODEL- M, INT, LEVEL HEADS TO BE VIKING -C-1, WELD PIPE CONFIGURATION TYPICAL ALL Ak,0- i!t;�:nj —BAR JOIST I* BEAM /—ANGLE IRON, PIPE OR STRUT THREAD ROD RING 2S TRAPEZE PIPE (_' 1 HALNGER FP- 1. 1 j SCALE, NOT TO SCALE tE,.�rlit Fm q g T M! MOW IMm =m 1 Em Ml m IM: m Im m EMS 0, Am d min NE WELD PIPE CONFIGURATION TYPICAL ALL Ak,0- i!t;�:nj —BAR JOIST I* BEAM /—ANGLE IRON, PIPE OR STRUT THREAD ROD RING 2S TRAPEZE PIPE (_' 1 HALNGER FP- 1. 1 j SCALE, NOT TO SCALE ALL -THREAD BAR JOISTROD UR 'BEAM PIPE RING PIPE ANGER FOR CONSTRUCTION V FROM SYSTEM c= SIGN : 11 GLOBE VL. yk0 APPROVED I -e WIWI) EXTERIOR WALL A! q g T Ap 17 ALL -THREAD BAR JOISTROD UR 'BEAM PIPE RING PIPE ANGER FOR CONSTRUCTION V FROM SYSTEM c= SIGN : 11 GLOBE VL. yk0 APPROVED I -e WIWI) EXTERIOR WALL A! 25 6 r APPROVED AS NOTED PLsmrs, MY OF S�m"JFORD SANFr `?O BUILDING DEPT. THESE PLANS ARE l:RE\;`li_':v=(D Ar'10 CONDITION -ALLY ACCEPTED FOR PERK111. A r-CRiMi-, '=SUED SHALL BE CONSTRUED TO BE A LIC -+- SE PROCEED WITH THE WORK AND NOT AS ia_ll riCr-i;T1 TO VIOLATE, CANCEL. ALTER, OR SEI ASIDE ANY OF THE PROVISIONS OF THE TECHNMCAL CODs q, NOR SHALL ALL -t ISSUANCE OF A PERMIT PREVENT ,iE BUILDING DEPT FROM THERE n,;rTP.V- !.�FQUiRING A CORREC- TION OF ERRORS THS vS. CONSTRUCTION OR OTHER VIO!.,,, rl-iE CODES, #oo Legal Description: Lot 3, Exxon 4-1054, according to the plat thereof, as recorded plat book 43, page 22 of the Public Records of Seminole County, Florida. ONI O 173.92' EXTENSION OF SOUTH / LINE M NOT PLATTED FOUND 4X4" CONCRETE •� z'�n" Ani 11' MONUMENT NO NUMBER FOUND 1/2" IRON PIPE LS 2040 N 8038'03" W 0.74' --9.9' FOUND 1/2 IRON ROD & o_ CAP RLS 2259 N 05'51'22' W 0.25' SITE BENCHMARK J1 y Q RAILROAD SPIKE IN vG� WDOD U77LITY.P01E ELEV. = 48.40' Cl tp 150.0' 1Jo- 0'12ZB' 10' UTILITY EASEMENT FOUND 4"X4' CONCRETE C)- BLOCK CORNER S 89 5447" W 307.84' FOUND 4X4" CONCRETE MONUMENT NO NUMBER FOUND 4X4" CONCRETE MONUMENT NO NUMBER MONUMENT NO NUMBER S 2175�'54" E 0.24' N 017fi 46" E 0.10' SPOT ELEVATiON� / (r)PicaL) x 49.24 LAKE MARY BOULEVARD x 48.88/ RIGHT OF WAY VARIES x 48.44 i POiNT OF CURVATURE i CURVE TABLE CURVE RADIUS DEL TA LENGTH CHORD BEARING C1 626.20 133355" 148.26 147.91 N71 *21'57"E C2 716.20 38 21 31 " 479.48 470.58 N83 4545 "E URVEYOR'S REPORT - zoo 1) Based on the National Flood Insurance Program FIRM" Map Community - Panel Number 120294 0045 E Dated 4/17/1995 the above described Property is located in Zone " X ". Areas determined to be outside the 500 year flood plain. 2) Bearings are based on: The South Right of Way line of Lot 3 being S 8954'47" W (per plat). 3) Vertical Datum Is based on: Site Benchmark 1, Railroad Spike In Wood Utility Pole, as having an Elevation of 48.40: (Per Site Dimension Plan by CPN, Dated June 2003). 4) The Surveyor has not abstracted the lands shown hereon for easements and/or rights of way of record. 5) No underground installations, foundation footings, or improvements have been located except as noted 6) There may be additional restrictions that are not recorded on this survey that may or may not be found in the public records of this county. 7) There is no evidence on the ground of use of the property which might suggest a possible claim of easement other than those shown on the survey. 8) This Survey was prepared for the Identities named hereon and is "nontransferable" 9) Improvements within their specific easements have not been located as a part of this survey. CERTIFICATION: I hereby certify that the survey represented on this map was made under my direction on the date shown based on the information furnished to me as noted and conforms to the MINIMUM TECHNICAL STANDARDS FOR LAND SURVEYING AND MAPPING IN THE STATE OF FLORIDA in accordance with CH.61Gi7-6, Florida Administrative Code. 40 of 4" VTR SEE SHEET ### FOR VENTING DETAIL 4 Not Water Cutlet( Cold Water Inlet® Gas Inlet ® a a a Q IIOV Power Supply TAr\MG I WATER H EAT E R SCALE: N.T.S. WALL MOUNTED DISHWASHER 2° W 4"FS-2 4" 7 SINK ICE MACHINE i ICE TEA BREWER lu PLUMBING DETAIL® ICE MACHINE ICE MACHINE WATER FILTER CEILING 3al� RUN 3/8" WATER LINE FROM FILTER TO ICE MACHINE HEAD ICE MACHINE 3/6" NPT CONNECTION ON BACK OF ICE MACHINE r. iia" PLUMBER TO RUN 1/2" COPPER DRAIN LINE FROM ICE MACHINE TO FLOOR SINK , 1/2" COLD WATER STUB OUT OF WALL @ q8" AFF a _ 3" Alli: GAP PLUMBER TO RUN 3/4" COPPER DIN DRAIN TO FLOOR 5114K FLOOR SINKS WATER FILTER DIAGRAM (TYP.) �` SCALE: N.T.S. TO EXIST. SEWER LINE GF 25nsF.T {I 2" AIR AP J C,O. ADDMITANCE DRINK DISU_U ER 3" V'tR I � HS u 12x12 FS 2" AIR �u 2„ ADDMITANCE 3" HUB PLANU 1R61N REVIEE H$ FD V CI T S AD ' FS 3 --- 12X12 FS 2" AIR All 4° ADDMITANCE qItJK 3" 14E�� 2' 3 CO 2 2„ ~� I FS AIR ADDMIT/ TIE TO EXISTING WASTE LINE IT lii7i 11111I SCALE: N.T.S. REQUIRENENTS WC'S 2 LAVS 1 i � M1 N0, 4" VTR SEE SHEET ### FOR VENTING DETAIL 4 Not Water Cutlet( Cold Water Inlet® Gas Inlet ® a a a Q IIOV Power Supply TAr\MG I WATER H EAT E R SCALE: N.T.S. WALL MOUNTED DISHWASHER 2° W 4"FS-2 4" 7 SINK ICE MACHINE i ICE TEA BREWER lu PLUMBING DETAIL® ICE MACHINE ICE MACHINE WATER FILTER CEILING 3al� RUN 3/8" WATER LINE FROM FILTER TO ICE MACHINE HEAD ICE MACHINE 3/6" NPT CONNECTION ON BACK OF ICE MACHINE r. iia" PLUMBER TO RUN 1/2" COPPER DRAIN LINE FROM ICE MACHINE TO FLOOR SINK , 1/2" COLD WATER STUB OUT OF WALL @ q8" AFF a _ 3" Alli: GAP PLUMBER TO RUN 3/4" COPPER DIN DRAIN TO FLOOR 5114K FLOOR SINKS WATER FILTER DIAGRAM (TYP.) �` SCALE: N.T.S. TO EXIST. SEWER LINE GF 25nsF.T {I 2" AIR AP J C,O. ADDMITANCE DRINK DISU_U ER 3" V'tR I � HS u 12x12 FS 2" AIR �u 2„ ADDMITANCE 3" HUB PLANU 1R61N REVIEE H$ FD V CI T S AD ' FS 3 --- 12X12 FS 2" AIR All 4° ADDMITANCE qItJK 3" 14E�� 2' 3 CO 2 2„ ~� I FS AIR ADDMIT/ TIE TO EXISTING WASTE LINE IT lii7i 11111I SCALE: N.T.S. NOTE: SUPPY 1/2" NATER LINE V� ITI-1 IN 10' OF BAG IN BOX RACK CONTRACTOR TO SUPPLY 410 CONDUIT WITH SHEEPS FOR LINE RUN. TUBING CANNOT BE RUN THROUGH q0" ELBOWS — CEILING �-- SWEEP ELBON 3(o" RECOMMENDED, 24 "OK" IF 36 WILLNOT NORK D15PENCER _L_. ___ _ 2" VTR y PLUMBING DETAIL - RETHERMALIZE L -CEILING EXHAUST HOOD CUTOFF VALVE 3/4" �! �o 3/4" COLD WATER STUB OUT OF WALL @ 65" AFF 3/4° STEAMER STEAMER WATER FILTER 3/4" NH CONNECTION ON BACK OF STEAMER TABLE 65" q PLUMBER TO RUN A 1 1/2" 120/60/lph SCO FOR COPPER DRAIN LINE FROM AuC5 STEAMER TO FLOOR 51NK m 3" AIR FLOOR //" `= SINKS �� I YGU• WATER FILTER DIAGRAM (TYP.) 1 CODE PLUME31 NG DATA PLUMBING DATA: PER FLORIDA BUILDING CODE, CHAPTER 4- TABLE 403.1 GROUP M -SUB CLASSIFICATION MERCANTILE TOTAL OCCUPANCY: 90.6 PEOPLE qO.6 PZOPLE/2 SEXES = 45.3 EACH 5EX MINIMUM # OF PLUMBING FIXTURES REQUIRED REQUIRENENTS WC'S 2 LAVS 1 PLUMBING SC-dEDULE N0, UTILITY 51ZE ROUGH -IN CONNECTION HEIGHT A,F.F. FLOOR WAL DFA BTU/hr CONNECTED TOVREMARKS FD FLOOR DRAIN_ 3 ---3r-- _-_1/2ff 137F 0 SEE PLUMBING NOTE F F5 FLOOR 5114K 3 3 FLUSH I EA. 12 GRA E SE^ DETAIL TH15 5HEET FFU FUDNEL FLOOR DRAIN 3°— 3' FLUSH A�HIGN FUNNEL FO INDIRECT WASTE FROM F XTURE! HSD HAND 51NK DRAIN/2 -I 1-172 12"BTC Uj ON NAND INK WASTE MSV MOP SINK DRAT ----2'-- 2' SU 2-1/4 O FREE FLOW INDIRECT HASTE INTO 14UB DPAII 5L BEVERAGE LINES section 1606, Florida Building 12 Code, 2001 edition C UNDER SLAB THE UP TIME WALL BEHIND v Thomas F Devgning 1727 S. Pinellas Avenue Tarpon .`springs, 34689 CJ J ICE MACHINE - TC GI00 GAS 1/ 110 QUICK DISCONNECT HOSE/ RESTRAINING CABLE BY CONCEPT SERVICES ILO HOT WATER I/2' 1/2 SU 4' ATC ON HOT FOOD UNI FAUCET GI15 GAS 3/ 108 ( 0 QUICK DISCONNECT HOSE/ RES�TRAIM G CABLE BY CONCEPT SERVICES G120 GAS 3/ 186 000 UICK DISCONNECT HOSE/ RESTRAINING CABLE BY CONCEPT SERVICES 125 COLD WATER 3/A 3/?� 65 TC ON STEAMER 7HRV FILTER - SEC DIAGRAM THIS EE7 G140 GAS 1/2 141138 35,W0 BTC ON RICE COOKERS 225 COLD WATER 1/2' 1/2 BTC ON ICE MACHINE THRU FILTER - SEE DiArRAM THIS SHEET. 305A HOT / COLD WATER 1/2' 1/2 BTC ON NAND SINK FAUCET 30 13 HOT / COLD WATER 1/2' I/2 TC ON MOP SINK FAU ET 315 NOT / COLD WATER 1/2' 1/ ft12 ATC ON SINK F UCET 320 HOT / COLD WATER 1/2 1/2 ATC ,ON 51NK FAUCET 330 OT WATER 140' F. 3/A"— 3/4'F— TC ON D15HWAS14ER - 52.2 G @20 si 345 H07 / COLD WATER 11/2" I/2 BTC ON PRE-RIN5E SPRAY FA CET 705 60—LDWATER3/611BTC ::F-,/— ON ICE MA�;HINE HEAD 710 COLD WATER 1/2 24 BTC ON ICE TU DISPENSER 720 COLD WATER 3/41 3/ 72 BTC ON FILTER NOTE: SUPPY 1/2" NATER LINE V� ITI-1 IN 10' OF BAG IN BOX RACK CONTRACTOR TO SUPPLY 410 CONDUIT WITH SHEEPS FOR LINE RUN. TUBING CANNOT BE RUN THROUGH q0" ELBOWS — CEILING �-- SWEEP ELBON 3(o" RECOMMENDED, 24 "OK" IF 36 WILLNOT NORK D15PENCER _L_. ___ _ 2" VTR y PLUMBING DETAIL - RETHERMALIZE L -CEILING EXHAUST HOOD CUTOFF VALVE 3/4" �! �o 3/4" COLD WATER STUB OUT OF WALL @ 65" AFF 3/4° STEAMER STEAMER WATER FILTER 3/4" NH CONNECTION ON BACK OF STEAMER TABLE 65" q PLUMBER TO RUN A 1 1/2" 120/60/lph SCO FOR COPPER DRAIN LINE FROM AuC5 STEAMER TO FLOOR 51NK m 3" AIR FLOOR //" `= SINKS �� I YGU• WATER FILTER DIAGRAM (TYP.) 1 CODE PLUME31 NG DATA PLUMBING DATA: PER FLORIDA BUILDING CODE, CHAPTER 4- TABLE 403.1 GROUP M -SUB CLASSIFICATION MERCANTILE TOTAL OCCUPANCY: 90.6 PEOPLE qO.6 PZOPLE/2 SEXES = 45.3 EACH 5EX MINIMUM # OF PLUMBING FIXTURES REQUIRED REQUIRENENTS WC'S 2 LAVS 1 URN'S 0 MISC. GA5 FRYER I PER 75 1 PER 200 144 �F lab WATER HEATER INSTANT IC10 NATURAL GAS RICE COOKER (I PER 500) 0 WC'S IAV5 URH'5 I FA. I EA. 0 EA. 0 EA. # OF PLUMBING FIXTURES PROVIDED REQUIRENENTS WC'S 2 LAVS 1 URN'S 0 D F 0 EA. N.C. SNAL.L PROVIDE Qu C FLEXIBLE CONNECTION I DISCONNECTAT EACI-I A� EQUIPMENT CONNECTION. SCALE: N.T.S. 1 %4" GAS PIPING DETAIL SCALE: N.T.S. PLAN NOTES - PLUMBING 1. CONNECT TO EXISTING SANITARY BUILDING DRAIN. VERIFY EXACT LOCATION, SIZE AND FLOW LINE IN FIELD. 2. TERMINATE I" INDIRECT WASTE OVER HUB DRAIN. 3, TERMINATE 1-1/2" INDIRECT WASTE. OVER FLOOR SINK, 4. TERMINATE 2" INDIRECT WASTE FROM DISHWASHER OVER FLOOR SINK. 5. PIPE ICE MAKER DRAIN AND BIN DRAIN INDIRECT WASTES AND TERMINATE SEPARATELY OVER FUNNEL DRAIN. 6. CONDENSATE DRAIN FROM COOLER REFRIGERATION UNIT BY MECHANICAL CONTRACTOR. 7. 6" DIAMETER SCHEDULE 40 PVC SODA TUBING,; CONDUITS TO BE INSTALLED BELOW THE FLOOR BY THE PLUMBING CONTRACTOR. ALL TURNS SHALL. BE ACCOMPLISHED WITH 22-1/2" AND 45 ELBOWS AND ENDS SHALL TERMINATE A MINIMUM OF 6" ABOVE THE FLOOR, KEEP NUMBER OF TURNS IN EACH RUN TO AE35OLUTE MINIMUM. REFER TO ARCHITECTS DRAWING A»-2 FOR LOCATION OF TERMINATION POINTS. ROUTING TO BE DONE IN FIELD. PROVIDE THE M05T DIRECT ROUTE POSSIBLE. a. INSTALL 5CHIER PRODUCTS CO. PATG-3050 RECESSED GREASE INTERCEPTOR WITH 6" EXTENSION, 1/4" STEEL NON --SKID COVER AND LIFT RINGS. UNIT TO HAVE 50 GPM FLOW RATE, 60 GALLONS LIQUID CAPACITY AND 220 POUNDS SLUDGE CAPACITY. r4, INSTALL APPROVED BACKFLOW PREVENTER ON 1/2" COLD WATER SUPPLY TO BAG-N-BO'X. 10, INSTALL APPROVED BACKFLOW PREVENTER ON 1/2" COLD WATER SUPPLY TO ICE MACHINE. WATER FILTERS TO BE FURNISHED BY THE SUPPLIER OF THE ICE MACHINE, 11. INSTALL APPROVED BACKFLOW PRI VENTER ON 1/2" COLD WATER SUPPLY TO STEAMER. WATER FILTERS TO BE FURNISHED BY THE SUPPLIER OF THE EQUIPMENT. 12• BRANCH COLD WATER TO SERVE PRE -RINSE. BRANCH HOT WATER TO SERVE DISHWASHER AND PRE -RINSE FAUCET. 13, BRANCH COLD WATER TO SERVE DRINK DISPENSER, AND TEA BREWER. INSTALL APPROVED BACKFLOW PREVENTER AND SHUT-OFF VALVE ON SUPPLIES TO DRINK DISPENSER AND TEA BRENER. 14. PLUMBING CONTRACTOR, TO CONNECT TO LANDLORDS DOMESTIC COLD WATER MAIN. INSTALL I-1/2" BALLVALVE, UNIONS IF REQUIRED AND INVENSYS SP POSITIVE DISPLACEMENT 1-1/2" METER WITH REMOTE READER. LOCATE REMOTE READER WHERE DIRECTED BY LANDLORD. 15. MAIN eACKFLOW PREVENTER BY OTHERS �— NATUR AL GAS REQUIRENENTS ITEM MBH GA5 FRYER 110 GAS CHARBROILER 144 36" GAS RESTAURANT lab WATER HEATER INSTANT IC10 NATURAL GAS RICE COOKER 35 ! AC LIOFN/I — — - — /'1OI — IRI — 1 -11 ITIC,.^ GENERAL NOTES I. FOOD SERVICE DRAWINGS ARE HEREIN MADE PART OF TA15 CONTRACTORS WORK. ALL PLUME3ING WORK INDICATED BY FOOD SERVICE DRAWINGS SHALL 15E PROVIDED IN THE CONTRACT. P.G. SHALL REVIEW AND REQUEST ANY CLARIFICATIONS PRIOR TO BID WHERE CONFLICTS MAY EXIST. 2. IT IS THE RESPONSIBII ITY OF THE PLUMBIN(,; CON"T"RACTOR TO CORRECTLY LOCATE THE ROUGH -INS AS INDICATED ON THE FOOD SERVICE PLANS TO ENSURE THAT THEY ARE: IN COMPLIANCE WITH ALL CODES, 3. PLUME31NG CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL ROUGH -INS, INDIRECT CONNECTIONS, INTER -CONNECTIONS, AND FINAL CONNECTIONS TO MAKE THE FOOD SERVICE EQUIPMENT OPERATIONAL. 4, PLUME31NG CONTRACTOR IS RESPONSIBLE FOR INSTALLING FAUCETS, TRAPS, LEVER WASTE5 AND 51MILAR ITEMS REQUIRED TO MAKE THE FOOD SERVICE EQUIPMENT OPERATIONAL.. 5. PLUMF31NG CONTRACTOR SHALL PROVIDE AND INSTALL ALL TRAPS, SHOCK ABSORBERS, BACKFLOW PREVENTION DEVICES, FLOOR SINKS, HUB DRAINS, PRESSURE REDUCING VALVES, TRIM PIECES AND OTHER SIMILAR ITEMS WHICH MAY BE REQUIRED TO MAKE FOOD SERVICE EQUIPMENT OPERATIONAL. G. THE PITCH OF THE FLOOR FOR ADDITIONAL DRAINS NOT RELATED TO THE FOOD SERVICE EQUIPMENT, SHALL BE DESIGNED BY THE A/E AND PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR, 7. ALL COLD AND HOT WATER LINES ARE TO BE INSTALLED ABOVE CEILING, UNLESS NO OTHER ROUTING IS POSSIBLE, CONTRACTOR IS RESPONSIBLE FOR PROVIDING INSULATION AS REQUIRED. 6. THE DISHWASHER SHALL BE INDIRECTLY DRAINED TO A FLOOR SINK, UNLESS LOCAL CODES PROHIBIT SUCH AN INSTALLATION. IN SUCH AREAS CONNECT DIRECTLY TO THE SEWER LINE AND PROVIDE A FLOOR SINK WITHIN 5 FEET OF DISHWASHER. q• ALL EXPOSED INDIRECT PIPING (FOR 3 -COMP SINK, ETC.) SHALL 13E COPPER WITH SOLDERED FI'ITING5 ONLY. NO PLASTIC (ABS, PVC, QHV, ETC.) PIPING ALLOWED ON EXPOSED PIPING. 10. PROVIDE SCALD PROTECTION TO LAVATORY$ PER THE DETAIL ON 5HEET PLO, GREASE TRAP CALCULATIONS Bq SEATS x 25 GALLONS x 12HR/12 x 1 = 2225 GALLONS PLUMBING FLAN SCALE: 1/4'' = 1' c U U) Z :j V LCA Q LO Z®�t o U_ It- F*- ZZ Q W ��✓ Z LLI IM ® 0 Z CL W 00 N U O INE 1i t, M It 04 W 00 Z Uj" �n �1 (°1``4 V r-. W W Z ®fn � 0 .W Zt' Uj U) z >L z -a ~8.0)0 - x'00OCL O O I -- U a #: 2508 R � N L ILS 0 r e*% O I Uj N UJ I I have reviewed this plan T_ O and said plan conforms with vl ai section 1606, Florida Building o Code, 2001 edition v Thomas F Devgning 1727 S. Pinellas Avenue Tarpon .`springs, 34689 CJ J (727) 937-9146 4" VTR SEE SHEET ### FOR. VENTING DETAIL---, CT1 4 Hat Water Outlet Cold Water Inlet Gas Inlet )> c e a a e IIOV Poyser Supply 1 WATER" HEATER' ,�.aCA L E N . . � . wALL r1ouNTEra jI5j!�H Rk tv A"FS--2 l SINK ICS MACHIN E I" ICE TEA BREWER C1u pRIN,_K DISP„�NSE'r �II e u 3" VTR 1.15 3" HUB DRAIN MS 12x12 2" AIR A nnMlrANv = DETAIL- ICE MACHINE ICE MACHINE WATER FILTER CEILING 3/8 RUN 3/0" WATER LINE \ FROM FILTER TO ICE MACHINE HEAD ICE MACHINE 3/13" NPT CONNECTION ON BACK OF ICE MACHINE a18" PLUMBER TO RUN 1/2" COPPER DRAIN LINE FROM ICE MACHINE TO FLOOR SINK i 1/2" COLD WATER STUB OUT OF WALL V 98" AFF 0 a U a BQ" i e 3" AIR v GAP m PLUMBER TO RUN 3/4" COPPER BIN DRAIN TO FLOOR `SINK FLOOR SINKS TERIlWA -R r'%IA -%RAM (T-Y"P.) LT SCALE: N.T.S. TO EX15T SEWER LINE 2" AIR ( yllyl' ADDMITANCE Y 2„ I 3 IFS A" 3 H5 " WC -meq FD 3" VTR 311 3u T HD PLUMBINK03"1 SCALE: N.T.S. / URINAL FD NOTE: SUPPY 1/2" NATER LINE WITH IN 10' OF E3AG IN BOX RACK CONTRACTOR TO SUPPLY 4"0 CONDUIT KITH SWEEPS FOR LINE RUN. TUBING CANNOT BE RUN THROUGH q0° ELBOWS CEILING SWEEP ELBOW 36" RECOMMENDED, 24 "OK" IF 36 HILLNOT NORK D15PENCER NO I E, I M-1 SCALE:'N.T.S. REQUIREMENTS WG'5 2 LAYS I PLUMBING,; SGNEDULE N0. UTILITY SIZE ` ROUG -IN CONNECTION NEIGH A.F.F. FLOOR WILL QFA BTU/hr CONNECTED TO:/REI"IARKS Fp FLOOR )RAIN 3" 3" -I/2 —B-r,- FF SEE PLUMBING NOTE F' F5_ F5 FLOOR SINK —3-3 FLUSH 1/2 GRATE aEE DETAIL TIS SHEET FFD FUNNEL FLOOR DRAIN 3 3 FLUSH 41 NIGH FUNNEL FO INUliI WASTE FROM FIXTURES H5D 4 AND SINK DRAIN 1-1/2 1-1/2 12' STC ON HAND SINK WASTE MSD MOP SINK DRAIN 2 2 SU 2--1/4 FREE 'rLCW INDIRECT WA5TE INTO NUB D6'AIN SL BEVERAGE LINES 12 PVC RJNDER SLAB THEN UP THE WALL BEHIND ICE MACHINE - BTC GI00 GAS I/2° 110 000 QUICK DISCONNECT NOSE/ RE51RAINING CABLE BY CONCEPT SERVICES 110 NOT WATER 1/2 112" SU A $TG ON NOT FOOD UNIT FAUCET 3/4 108 000 QUICK DISCONNECT HOSE/ RESTRAINING CABLE BY CONCEPT SERVICES GII5 GAS 3/4 16i 000 QUICK, pISCONNECT NOSE/ RESTRAINING Cr BLE BY CONCEPT SERVICES GI20 GAS 3/4 3/4 651T— ' BTC ON STEAMER THRU FILTER - SEE DIAGRAM THIS 51 E l 125 CIAO COLD WATER GAS 1/2 —1/2'--38 55,000 BTC ON RICE G:OOKERS 225 COLD WATER 1/2 112 98' BTC ON ICE MACHINE THRU FILTER - SEE DIAD M THIS SHEET_ 305A NOT /GOLD WATER I/2 1/2 16' BTG ON HAND SMK FAUCET lG5B NOT / COLD WATER 112" 112 36` $TG ON MOP SINK FAUCET 315 HOT /COLO WATER 112 /; 16 $TG ON SIN FAUCET 320 HOT / COLD WATER I/2 If2 16 12' BTC ON SINK FAUCET BTC ON DI511 ASNER - 52.2 GRH@ 20 psi 330 NOT WATER 140 f•� 3/A 112 3/A 112 I6' BTC ON PRE-RINSEPRA7 FAUCET 345 NOT / COLD WATER 75OLD 3/8 BTC ON ICE MACHIN♦^ HEAD 705 710 WATER COLD WATER I/2 I/2 24' BTC ON ICE 'TEA DISPENSER 720 COLD WATER 3/4 3/4 72 BTG ON FILTER NOTE: SUPPY 1/2" NATER LINE WITH IN 10' OF E3AG IN BOX RACK CONTRACTOR TO SUPPLY 4"0 CONDUIT KITH SWEEPS FOR LINE RUN. TUBING CANNOT BE RUN THROUGH q0° ELBOWS CEILING SWEEP ELBOW 36" RECOMMENDED, 24 "OK" IF 36 HILLNOT NORK D15PENCER NO I E, I M-1 SCALE:'N.T.S. I- -CEILING EXHAUST HOOD CUTOFF VAALVVE'" 3/4" 3/4" COLD WATER ST1JB OUT OF WALL Q 65" AFF 3/4" STEAMER STEAMER WATER FILTER 3/4" NH CONNECTION ON BACK OF STEAMER TABLE m 66" m m 120/0/Iph PLUMBER TO RUN A 1 1/2" SCO FOR COPPERDRAIN LINE FROM AUCs m 5TEAMER TO FLOOR SINK a m m S' AIR i� CTAP FLOOR SINKS WATERI LT I 1 G�I (TYP. T._ SCALE: N.T.S. 71 CODE PLUMBING DATA PLUMBING DATA: PER FLORIDA BUILDINfi CODE, CHAPTER 4- TABLE 403.1 GROUP M -SUB CLASSIFICATION MERCANTILE TOTAL OCCUPANCY: q0.1a PEOPLE 90.6 PEOPLE/2 5EXE5 = 46.3 EACH SEX MIAIIMUM # OF PLUMBING FIXTURES REQURED REQUIREMENTS WG'5 2 LAYS I PLUMBING DETAIL - RETHERMALIZF I PER 75 I- -CEILING EXHAUST HOOD CUTOFF VAALVVE'" 3/4" 3/4" COLD WATER ST1JB OUT OF WALL Q 65" AFF 3/4" STEAMER STEAMER WATER FILTER 3/4" NH CONNECTION ON BACK OF STEAMER TABLE m 66" m m 120/0/Iph PLUMBER TO RUN A 1 1/2" SCO FOR COPPERDRAIN LINE FROM AUCs m 5TEAMER TO FLOOR SINK a m m S' AIR i� CTAP FLOOR SINKS WATERI LT I 1 G�I (TYP. T._ SCALE: N.T.S. 71 CODE PLUMBING DATA PLUMBING DATA: PER FLORIDA BUILDINfi CODE, CHAPTER 4- TABLE 403.1 GROUP M -SUB CLASSIFICATION MERCANTILE TOTAL OCCUPANCY: q0.1a PEOPLE 90.6 PEOPLE/2 5EXE5 = 46.3 EACH SEX MIAIIMUM # OF PLUMBING FIXTURES REQURED REQUIREMENTS WG'5 2 LAYS I URN'S, 0 MISC. GAS FRYER I PER 75 1 PER 200 14A DF (I PER 500) 186 µNC.'S LAVS URN"� 35 I EA. I EA. 0 EA, 0 EA. # OF PLUMBING FIXTURES PROJIDED REQUIREMENTS WG'5 2 LAYS I URN'S, 0 D F 0 EA. N PROVIDE D �. M.G. SHALL P E �3Q �A�li CKBLE CONNECTION U15CC NNE -l" I Al EI TH QUICK I EQUIPMENT CONNECTION. I V" P �•{j %4° I11 lg�� V 4' IoNA Y4" r�g�RQI �4' ` 110��h 7 Y" CPIPING E TAIL SCALE: N.T.S. ,PLAN NOTES — PLUMBING I. CONNECT TO EXISTING SANITARY BUILDING DRAIN. VERIFY EXACT LOCATION, SIZE AND FLOWI LINE IN FIELD. 2. TERMINATE I" INDIRECT WASTE OVER NUB DRAIN. 3, TERMINATE 1-1/2" INDIRECT WASTE OVER FLOOR 511 A. TERMINATE 2" INDIRECT WASTE FROM DISHWASHER OVER FLOOR SINK. 5. PIPE ICE MAKER DRAIN AND BIN DRAIN INDIRECT WASTES AND TERMINATE SEPARATELY OVER FUNNEL DRAIN. 6. CONDENSATE DRAIN FROM COOLER REFRIGERATION UNIT BY MECHANICAL CONTRACTOR, 7. 6" DIAMETER SCHEDULE AO PVC SODA TUBING CONDUITS TO BE INSTALLED BELOW THE: FLOOR BY TOE PLUMBING CONTRACTOR. ALL TURNS SHALL BE ACCOMPLISHED WITH 22-1/2" AND 45 ELBpW5 AND ENDS SHALL TERMINATE A MINIMUM OF 6" ABOVE THE FLOOR. KEEP NUMBER OF TURNS IN EACH RUN TO ABSOLUTE MINIMUM. REFER TO ARCHITECTS DRAWING A-2 FOR LOCATION OF TERMINATION POINTS. ROUTING TO BE DONE IN FIELD, PROVIDE THE MOST DIRECT ROUTE 1`055IBLE. 8. INSTALL SGHIER PRODUCTS CO. PATE -3050 RECE55ED GREASE INTERCEPTOR WITH 0" EXTENSION, I/I4" STEEL NON-SKID COVER AND LIFT RINGS. UNIT TO HAVE 50 GPM FLOW RATE, 60 GALLONS LIQUID CAPACITY AND 220 POUNDS SLUDGE CAPACITY. q INSTALL APPROVED BACKFLOW PREVENTER ON 1/2" COLD WATER SUPPLY TO BAG-N-ZlOX. 10. INSTALL APPROVED BACKFLOW PREVENTER ON 112" COLD WATER SUPPLY TO ICE MACHINE. WATER FILTERS TO BE FURNISHED BY THE SUPPLIER OF THE ICE MACHINE. 11. INSTALL APPROVED BACKFLOW PREVENTER ON 1/2" COLD WATER SUPPLY TO STEAMER. WATER FILTERS TO BE FURNISHED BY THE SUPPLIER OF THE EQUIPMENT. i2• BRANCH COLD WATER TO SERVE PRE -RINSE. BRANCH HOT WATER TO SERVE DISHWA5HER AND PRE -RINSE FAUCET. 13, BRANCH COLD WATER TO SERVE DRINK DISPENSER AND TEA BREWER, INSTALL APPROVED BACKFLOW PREVENTER AND SHUT-OFF VALVE ON SUPPLIES TO DRINK DISPENSER AND TEA BREWER. IA. PLUMBING CONTRACTOR TO CONNECT TO LANDLORDS DOMESTIC COLD WATER MAIN. INSTALL 1-112" BALL-VALVE, UNIONS IF REQUIRED AND INVENSYS 5R POSITIVE D15PLACEMENT 1-1/2" METER WITH REMOTE READER. LOCATE REMOTE READER WHERE DIRECTED BY LANDLORD. 15. MAIN BACKFLOW PREVENTED BY OTHERS NATURAL GAS REQUIREMENTS ITEI I MBN GAS FRYER 110 GAS CHARBROILER 14A 36" GAS RESTAURANT 186 WATER HEATER INSTANT Iq0 NATURAL GAS RICE COOKER 35 GAS PROVIDED BY : FLORIDA PUBLIC UTILITIES GErJERAL NOTES I. FOOD SERVICE DRAWINGS ARE HEREIN MADE PART OF THIS CONTRACTORS WORK. ALL PLUMBING WORK INDICATED BY FOOD SERVICE DRAWINGS 514ALL BE PROVIDED IN THE CONTRACT, P,C. SHALL REVIEW AND REQUEST ANY CLARIFICATIONS PRIOR TO BID WHERE CONFLICTS MAY EXIST. 2. IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO CORRECTLY LOCATE THE ROUGH -INS AS INDICATED ON THE FOOD SERVICE PLANS TO ENSURE THAT THEY ARE IN COMPLIANCE WI`T'H ALL CODES. 3. PLUMBING CONTRACTOR 15 RESPONSIBLE FOR PROVIDING ALL ROUGH -INS, INDIRECT CONNECTIONS, INTER -CONNECTIONS, AND FINAL CONNECTIONS TO MAKE THE FOOD SERVICE EQUIPMENT OPERATIONAL, 4, PLUMBING CONTRACTOR 15 RESPONSIBLE FOR INSTALLING FAUCETS, TRAPS, LEVER WASTES AND SIMILAR ITE1 15 REQUIRED TO MAKE THE FOOD SERVICE EQUIPMENT OPERATIONAL. 5. PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL TRAPS, SHOCK ABSORBERS, BACKFLOW PREVENTION DEVICES, FLOOR SINKS, HUB DRAINS, PRESSURE REDUCING VALVES, TRIM PIECES AND OT14ER SIMILAR ITEMS WHICH MAY BE REQUIRED TO MAKE FOOD SERVICE EQUIPMENT OPERATIONAL. 6. THE PITCH OF THE FLOOR FOR ADDITIONAL DRAINS NOT RELATED TO THE FOOD SERVICE EQUIPMENT, SHALL BE DE5IGNED BY THE A/E AND PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR. 7. ALL COLD AND HOT WATER LINES ARE TO BE INSTALLED ABOVE CEILING, UNLE55 NO OTHER ROUTING; IS POSSIBLE. CONTRACTOR IS RESPONSIBLE FOR PROVIDING INSULATION AS REQUIRED. 8. THE DISHWASHER SHALL BE INDIRECTLY DRAINED TO A FLOOR SINK, UNLESS LOCAL CODES PROHIBIT SUCH AN INSTALLATION. IN SUCH AREAS CONNECT DIRECTLY TO THE SEWER LINE: AND PROVIDE A FLOOR 51NK WITHIN 5 FEET OF D15HWASHER. 9. ALL. EXPOSED INDIRECT PIPING (FOR 3 -COMP SINK, ETC.) SHALL BE COPPER WITH SOLDERED FITTINGS ONLY. NO PLASTIC (AB5, PVC, DWV, ETC.) PIPING ALLOWED ON EXPOSED PIPING. 10, PROVIDE SCALD PROTECTION TO LAVATORYS PER THE DETAIL ON SHEET PI.O. GREASE TRAP CALCULATIONS 89 SEATS x 25 GALLONS x 12HR/12 X I = 2225 GALLONS C:\acadfiies\ 2508-Qcivba\2508-06-Plumbirlg.c