HomeMy WebLinkAbout4 Carriage Cove Way7BY:
CIV CITY OF SANFORD
AY
OB bI 1 DIN & FIRE PREVENTION
MIT APPLICATION,
Z..
Application No: - 1 7 LILp Documented Construction Value: $ 3 OO "
cc:)
Job AAdress: ('ova SVA! 4 Historic District: Yes No
Parcel ID• Zoning:
Description of Work:
Plan Review Contact Person: Title: `
Phone: L/07 -4151-31'141 Fax: E-mail:
Pro ert Owner Information 0pY
Name t4w;ld - CYvZ 4'1 Vera. Phone: "109 V S 5-319V'
Street: LVA- b 2 • Resident of property?
City, State Zip:
Contractor Information
Name Phone:
Street: Fax:
City, State Zip: State License No.:
Architect/Engineer Information
Name: Phone:
Street: Fax:
City, St, Zip: E-mail:
Bonding Company: Mortgage Lender:
Address: a Address:
7c = 2,50, o 4
r.
PERMIT INFORMATION
Building Permit
Square Footage: Construction Type: No. of Stories:
No. of Dwelling Units: Flood Zone: ;
Electrical Plumbing
New 'Service - No. of AMPS: New Construction - No. of Fixtures:
Mechanical (Duct layout required for new systems) Fire Sprinkler/Alarm 11 No. of heads:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no
work or installation has commenced prior to the issuance of a permit and that all work will be performed to
meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit
must be secured `for, electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and
air conditioners, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF COMMENCEMEI IT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FI FIs' IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LOR : A$VORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this
property that may be found in the public records of this county, and there may be additional permits required
from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida
Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order
to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the
plan review fee based on past permit activity levels. Should calculated charges exceed the documented
construction value when the executed contract is submitted, credit will be applied to your permit fees when the
permit is released.
au'JUA &,
Signature of Owner/Agent
pp
Date,
Acs r `a C UZ. ice. .9-Q ci,
Print Owner/Agent's Name !,/
12-1 G
Signature of Notary -State o Flonda Date
SC iii
ON
Expol,. ,/
G
Qevoa 116 2plyFd,%c
Owner/Agent is Personal
Produced ID Type of
APPROVALS: ZONING:
COMMENTS:
UTILITIES:
Signature of Contractor/Agent Date
Print Contractor/Agent's Name
Signature of Notary -State of Florida Date
Contractor/Agent is Personally Known to Me or
Produced ID Type of ID
WASTE WATER:
ENGINEERING: FIRE: BUILDING:
Property Address: lyrQ-y educt b7 3 2 7
I, , do hereby state that I am qualified
and capable of performing the requested construction involved with the permit application filed and agree to the
conditions specified above.
2o`Zaii
Signature of Owner -Builder S oNor4Fs ••. e
Date
p=
0 Ldp®
Form of Identification
m6stv Motoom, e: k
i •._
000
T_o Q.>
A violation of this exemption is a misderYf 9 first degree punishable by a term of imprisonment
not exceeding 1 year and a $1,000.00 fine inii addition to any civil penalties. In addition, the local
permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy
for unlicensed activity against the owner and any person performing work that requires licensure under
the permit issued.
Rev. 9.14.2009
I agree that, as the party legally and financially responsible for this proposed construction activity, I will
abide by all applicable laws and requirements that govern owner -builders as well as employers. I also
understand that the construction must comply with all applicable laws, ordinances, building codes, and
zoning regulations. '
I am of aware of construction practices and I have access to the Florida Building Codes.
I understand that I may obtain more information regarding my obligations as an employer from the Internal
Revenue Service, the United States Small Business Administration, the Florida Department of Financial
Services, and the Florida Department of Revenue. I also understand that I may contact the Florida
Construction Industry Licensing Board at' 1-850-487-1395 or at www.myGorida.com/dbpr/pro/cilb/ for
more information about licensed contractors.
I am aware of, and consent to, an owner -builder building permit applied for in my name and understand
that I am the party legally and financially responsible for the proposed construction activity at the address
listed below.
n/ I agree to notify the building department immediately of any additions, deletions, or changes to any of the
1 information that I have provided on this disclosure or in the permit application package.
Licensed contractors are regulated by laws designed to protect the public. If you contract with a person
who does not have a license, the Construction Industry Licensing Board, the Department of Business and
Professional Regulation and the building department may be unable to assist you with any financial loss
that you sustain as a result of a complaint. Your only remedy against an unlicensed contractor may be in
civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an
individual or firm is injured while working on your property, you may be held liable for damages. If you
obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying
whether the contractor is property licensed and the status of the contractor's workers' compensation
coverage.
Property Address: lyrQ-y educt b7 3 2 7
I, , do hereby state that I am qualified
and capable of performing the requested construction involved with the permit application filed and agree to the
conditions specified above.
2o`Zaii
Signature of Owner -Builder S oNor4Fs ••. e
Date
p=
0 Ldp®
Form of Identification
m6stv Motoom, e: k
i •._
000
T_o Q.>
A violation of this exemption is a misderYf 9 first degree punishable by a term of imprisonment
not exceeding 1 year and a $1,000.00 fine inii addition to any civil penalties. In addition, the local
permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy
for unlicensed activity against the owner and any person performing work that requires licensure under
the permit issued.
Rev. 9.14.2009
OWNER BUILDER STATEMENT/AFFID"IT
Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford,
Seminole County, Winter Springs
Florida Statutes are quoted here in part for your information to indicate the authority for exemptions for
homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities. -
OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT
BY SIGNING THIS STATEMENT, I ATTEST THAT: (Initial to the left of each statement)
I understand that state law requires construction to be done by a licensed contractor and have applied for
an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of
the property listed, may act as my own contractor with certain restrictions even though I do not have a
license.
Rev. 9.14.2009
understand that building permits are not required to be signed by a property owner unless he or she is
L
I
responsible for the construction and is not hiring a licensed contractor to assume responsibility.
I understand that, as an owner -builder, I am the responsible party of record on a permit. I understand that I
n, may protect myself from potential financial risk by hiring a licensed contractor and having the permit fled
n Cr in his or her name instead of my own name. I also understand that a contractor is required by law to be
licensed in Florida and to list his or her license numbers on all permit and contracts.
I understand that I may build or improve a one -family or two-family residence or a farm outbuilding. I
may also build or improve a commercial building if the costs do not exceed $75,000. The building or
forresidencemustbeformyownuseoroccupancy. It may not be built or substantially improved sale or
lease. If a building or residence that I have built or substantially improved myself is sold or leased withinVin1yearaftertheconstructioniscomplete, the law will presume that I built or substantially improved it
for sale or lease, which violates this exemption.
I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction.
I understand that I may not hire an unlicensed individual person to act as my contractor or to supervise
Ipersonsworkingonmybuildingorresidence. It is my responsibility to ensure that the persons whom
employ have the licenses required by law and by city ordinance.
I understand that it is a frequent practice of unlicensed persons to have the property owner obtain an
owner -builder permit that erroneously implies that the property owner is providing his or her own labor
and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for anyGinjuriessustainedbyanunlicensedpersonorhisorheremployees=while working on my property. My
homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -
builder and am aware of the limits of my insurance coverage for injuries to workers on my property.
I understand that I may not delegate the responsibility for supervising work to a licensed contractor who is
not licensed to perform the work being done. Any person working on my building who Is not licensed
Gr" must work under my direct supervision and must be employed by me, which means that I must
comply with laws requiring the withholding of federal income tax and social security contributions
under the Federal Insurance Contributions Act (FICA) and must provide workers' compensation
for the employee. I understand that my failure to follow these laws may subject me to serious financial
risk.
Rev. 9.14.2009
PERMIT # c7 y&
STORAGE ROOM ADDITION
c
AWILDA CRUZ & WENDEL TEIXEIRA
4 CARRIDGE COVE AY
SANFORD, FLORIDA
407) 459-3194
DESIGN LOADS IN ACCORDANCE WITH FABC ARE:
ROOF LOADS 20 PSF
WIND LOADS 110 MPH (PER ASCE 7)
INTERIOR PARTITIONS 5 PSF PERPENDICULAR TO THE FACE OF THE WALL
LUMBER GRADES SHALL BE A MINIMUM OF
HEADERS, COLUMNS, BEAMS 81 OVERBUILD FRAMING #2SYP FB=1500 PSI
WALLS, BLOCKING AND MISCELLANEOUS #2 SPF
SILL PLATES #2 SYP PT
PT LUMBER SHALL ALSO BE UTILIZED WHEREVER INDICATED ON DWGS
SANFORD BUILDING DEPT.
THESE PLANS ARE REVIEWED AND CONDI OMLI%'
ACCEPTED FOR PERMIT. A PERMIT ISSUED SHALL BC -
CONSTRUED TO BE A LICENSE TO PROCEED WITH
THE WORK AND NOT AS AUTHORITY TO VIOLATE,
CANCEL, ALTER, OR SET ASIDE ANY OF THE
PROVISIONS OF THE TECHNICAL CODES, NOR SHALL
ISSUANCE OF A PERMIT PREVENT i .!E BUILDING
DEPT FROM THEREAFTER P 01-',:ING A CORREC-
TION OF ERRORS ON THE F INSTRUCTION
OR OTHER VIOLATIONS OF THL C --DES.
APPLICABLE CODES
2007 FLORIDA EXISTING BUILDING CODE WITH 2009 SUPPLEMENT(S)
LEVEL 2 ALTERATION
2007 FLORIDA FIRE PREVENTION CODE
2008 NATIONAL ELECTRIC CODE
2006 NFPA I AND NFPA 101 FLORIDA EDITION
FLORIDA STATUTES
FLORIDA ADMINISTRATIVE CODE
SANFORD CITY ORDINANCES
WIND DESIGN
BASIC WIND SPEED ---------110 MPH
IMPORTANCE FACTOR----- I
EXPOSURE ---------------- B
INT PRESSURE COEFFIC-- .18
DRAWINGS
I COVER /DATA
2 SITE
3 FLOOR PLAN
4 ELEVATIONS
5 FOUNDATION
6 ROOF FRAMING
7 SECTION
8 DETAILS
SCOPE OF THE WORK
U
W
SR 427
SUNOCO
GAS STATION
LOCATION
MODIFY AN EXISTING STORAGE SHED TO INCREASE SIZE AND TO
PROVIDE COVERED ACCESS. THIS IS NOT A HABITABLE SPACE.
THESE DRAWINGS DELINEATE THE ASBUILT CONDITION WITH REMEDIAL
REQUIREMENTS TO BRING THE EXISTING STORAGE ROOM INTO CODE
COMPLIANCE
I
ANDREW
ARCHIL
AR OQO
SITE
AN REVIEW
31ERVICES
0"
1
1
UNIT DIMENSIONS
1/8" + I'-0"
I
2
7/8" TEK SCREWS @ 12" OC
ON ALL PANEL SIDE LAPS
EURETHANE CAULK
7" BETWEEN SHEETS
AT ALL LAPS
AT ROOF = PEEL N SEAL
OR 2 LAYERS 15# FELT
AT WALLS = 15# FELT
OR TYVEK HOUSE WRAP
FASTNERS 32" OC
LENGTH OF PANEL AT ROOF
INTO 2x4 FLAT PURLINS AT ROOF)
INTO TOP PLATE BOTTOM PLATE
AND INTO BLOCKING AT 4' AFF AT WALLS)
9 HEX HEAD SCREW x 1 1/2 WITH
SEALING WASHER (WSW)
METAL PANEL ATTACHMENT DETAIL
NAILING:
WALLS - 6D COMMON @ 6" OC ALL OSB EDGES
AND 12: OC AT ALL INTERMEDIATE SUPPORTS
IE SOLID BLOCKING AT MID WALL HEIGHT AND
BLOCKING AT ALL PANEL JOINTS)
ROOF - 6D COMMON @ 6" OC ALL OSB EDGES
AND 12: OC AT ALL INTERMEDIATE SUPPORTS
IE FLAT 2x4 PURLINS)
METAL DECK - #9 x 1 1/2" HEX HEAD SCREWS
WITH SEALING WASHER - INSTALL FASTNERS
32" OC ALONG THE LENGTH OF PANELS AT ROOF
INTO 2x4 FLAT PURLINS AT ROOF) AND
INTO THE TOP PLATE, BOTTOM PLATE
AND INTO BLOCKING AT 4' AFF AT WALLS)
2
EXISTING 1/2" OSB i 5
AND METAL PANELS 8 REFRAME THE
ADD MOISTURE PROOFING , --- 'OBOTTOM OF THIS
ALL AROUND RE -NAIL 2 i M
OSB AT SPECIFIED SPACING i z AFTER ADDING
ALL STUDS AND JOISTS FOOTINGS
4'--I 2'-7 1/2" f --
iEXISTINGFOOTBOLTSEADOOR
AND 2x4 BAR CLOSER AT MID DOR ZD
FIELD CONSTRUCTED DOORS -ADD 2x4 BAR CLOSER TO UPPER ND
WITH 2x4 FRAME AND OSB i LOWER HALVES OF DOOR FOR
FINISH RE -NAIL OSB i STORM WIND RESISTANCE
AS SPECIFIED
NEW 2x4 STUDS
@ 16" OC i
EXISTING 2x4 ST DSADDA2x4TOTHISDOOR-
DOUBLE
OOR
DOUBLE THE TOP I -----------------------------------------------------------
PLATE TO THE
FIRST EXISTING
I7'-4"
STUD
PLAN
1/4" + 1'-0"
3
2x4 DOOR FRAME
1/2" OSB DOOR PANEL
2-"T* HINGES EACH DOOR
EXISTING
OPENING
DESIGN
PRESSURES
METAL SIDING
12.5
15.9
LSTA9
2x4 STUDS
9::2x4 REMOVEABLE BAR
STD MTL BAR BRACKET
3/8 x 2 1/2 LAG(S)
DOOR FROM INSIDE DOOR BAR(S)
NEW REMOVEABLE SLIDING DOOR BARS
EXISTING DOOR BAR
ADD A FLAT ALUMINUM COVER PLATE
Ix4 HARDIE BOARD
FRONT ELEVATION
1/4" = 1'-0"
METAL SIDING
PRIME AND PAINT
NOTE: APPLY EURETHANE CAULK
TO SEAL ALL JOINTS AND GAPS
SIDE ELEVATION
1/4" = I'-0"
4
ANDREW KUTZ
ARCHITECT
AR00006491/
COM
I
i
METAL SIDING
12.5
15.9
LSTA9
2x4 STUDS
9::2x4 REMOVEABLE BAR
STD MTL BAR BRACKET
3/8 x 2 1/2 LAG(S)
DOOR FROM INSIDE DOOR BAR(S)
NEW REMOVEABLE SLIDING DOOR BARS
EXISTING DOOR BAR
ADD A FLAT ALUMINUM COVER PLATE
Ix4 HARDIE BOARD
FRONT ELEVATION
1/4" = 1'-0"
METAL SIDING
PRIME AND PAINT
NOTE: APPLY EURETHANE CAULK
TO SEAL ALL JOINTS AND GAPS
SIDE ELEVATION
1/4" = I'-0"
4
ANDREW KUTZ
ARCHITECT
AR00006491/
COM
I
IFOUNDATION NOTES
ALL CONCRETE SHALL BE MININUM 2500 PSI AT 28
IDAYS
ALL REINFORCING STEEL SHALL BE #5 OR
GREATER, GRADE 60 DEFORMED STEEL
ALL REINFORCING STEEL IS TO HAVE A MINIMUM
OF 3 INCH CONCRETE COVERAGE
ALL REINFORCING STEEL JOINTS SHALL LAP A
MINIMUM OF 40 BAR DIAMETERS OR 25 INCHES
WHICHEVER IS GREATER
ALL LUMBER IN CONTACT WITH MASONRY SHALL
IBE PRESSURE TREATED
4
SEE DETAIL $
DRILL EXIST SLAB
NEW GALV FLASHING
AND INSERT I/2x12
THREADED ROD
f—FINISH GRADE
GRADE VARIES
Z
Z
x
l° • co 2x2 PLATE WASHER
I
WITH NUT EACH SIDE
12" MIN --I
NEW FOOTING
THE NEW FOOTING WHICH
WILL SHOW ABOVE GRADE
FOUNDATION
1/4" + 1'-0"
5
ANDREW KUT
ARCHITEC
AR000 6 I
4 ,7) 3 2- 5
U CSC COM
EI II
I LU26
2 LU24 2- 3/8 X 3 LAG o
o H RAFTERS TO LEDGER
LEDGER 4-I01)
o , RAFTER (2x4) 2-I01)
RAFTER (2x6) 4-I01) INDICATES
CONCEALED I - 3/8 x 3
FLANGES
3 LU 26Z
END RAFTERS TO LEDGER
CONCEALED FLANGES)
LEDGER 4-I01)
RAFTER (2X4) 2-I01)
RAFTER (2x6) 4-101)
3 H3
TOP PLATE AND PURLINS TO RAFTER
PLATE 4-8D
RAFTER 4-81)
4 H4
BOTTOM PLATE TO STUDS
PLATE 4-8D
STUD 4-8D
5 A34
HEADER TO RAFTERS
8- 8D x 1 1/2
6 LST9
DOOR JAMB STUDS TO HEADER
8 -IOD
NEW 2x4
REOD FOR
DOOR Ti
2X6
ADD NEW I
2x4 FLAT
EXISTING I
2x4 FLA
NEV
32" 32"
16" LEDGER BOARD
2X6
7 TP15
STAIR STRINGERS TO STUDS
13 - HOLES
MIN 8- 8D x 1 1/2
CONNECTORS (SIMPSON)
ROOF FRAMING PLAN
1/4" + 1'-0"
FOR NAILING SEE DRAWING 3
ANDREW KL
ARCHITE9
AR 064
40 ) 22-3
UT 0 L.
J NE , 2
STAIRS
I
I
I
I
L----------I
N I
EXISTING SLAB
NOTE - DO NOT REMOVE ANY STRUCTURE UNTIL
SECURE TEMPORARY BRACING HAS BEEN
INSTALLED TO SUPPORT ALL STRUCTURE
NOTE - INSTALL SOLID BLOCKING AT ALL OSB
JOINTS AND SECURE AT THE SPECIFIED SPACING
NOTE - DIG FORM AND POUR THE NEW FOOTING
IN SECTIONS SO THERE IS A LIMITED AREA OF
SLAB THAT IS iUNDERCUT AT ANY TIME.
CROSS SCECTION
3/4" = 1'-0"
0
Ml
H4
METAL SIDING PANELS
RESECURE .AS SPECIFIED
SOLID BLOCKING AT 4'AFF
15# FELT OR TYVEK
HOUSE WRAP
1/2" OSB EXISTING
SECURE AS SPECIFIED
EXISTING 2x4 PT PLATE
NEW ANCHOR BOLTS
AS DETAILED
NEW FOOTING WITH 2#5 7
ANDREW Ki
EXISTING PURLINS 2x4 FLAT METAL PANELS - SECURE AS DETAILED
NEW PURLINS 2x4 FLAT @ 16" OC
NEW (PEEL N SEAL MEMBRANE
OR 2 LAYERS OF 15 # FELT
1/2" OSB BOARD - SECURE AS SPECIFIED
12
NEW FOAM
NEW CLOSER STRIP
FLASHING
NEW HARDIE
NEW JOIST BOARD DRIP EDGE
HANGAR ALL AROUND
EXISTING 2x4 RAFTER TO
NEW 2x6 PT BE REPLACED WITH 2x6
WITH 3/8" LAGS
H3
NEW 2x6 RAFTERS @ 16" OC 3
2x4 STUDS @ 16" OC
8 NEW AND EXISTING
STAIRS
I
I
I
I
L----------I
N I
EXISTING SLAB
NOTE - DO NOT REMOVE ANY STRUCTURE UNTIL
SECURE TEMPORARY BRACING HAS BEEN
INSTALLED TO SUPPORT ALL STRUCTURE
NOTE - INSTALL SOLID BLOCKING AT ALL OSB
JOINTS AND SECURE AT THE SPECIFIED SPACING
NOTE - DIG FORM AND POUR THE NEW FOOTING
IN SECTIONS SO THERE IS A LIMITED AREA OF
SLAB THAT IS iUNDERCUT AT ANY TIME.
CROSS SCECTION
3/4" = 1'-0"
0
Ml
H4
METAL SIDING PANELS
RESECURE .AS SPECIFIED
SOLID BLOCKING AT 4'AFF
15# FELT OR TYVEK
HOUSE WRAP
1/2" OSB EXISTING
SECURE AS SPECIFIED
EXISTING 2x4 PT PLATE
NEW ANCHOR BOLTS
AS DETAILED
NEW FOOTING WITH 2#5 7
ANDREW Ki
PEEL N SEAL
MEMBRANE
PEEL N SEAL
4" MIN
COVERED WITH 2" MIN 1/2 OSB PEEL N SEAL CORREGATED
FOAM CLOSER STD 1.25 x 1.25
SHEATHING EXISTING MEMBRANE METAL ROOFINGROOFCOATING STD
S GALV DRIP 1/2' 0
GALV
METAL DECK 2X4 FLAT SHEATHI
DRIP
PEEL N SEAL MEMBRANE 0 16' OC
EXISTING
1/2" OSB SHEATHING EXISTING PURLINS 2x6 RAFTER
ZX4 FL,gr PIx4 HARDIE BD
AT 16" OC
RUNS 016.OC
4-1/4x3
WOOD SCREW QMETALSIDING
EVERY STUD Ix4 HARDIE
NEW 2x6 PT LEDGER 21(6 EVERY
0 16" 30# FELT BOARD
SECURE WITH 2 3/8"x3 LAGS OC
IN MANUFACTURED + OR TYVEK 2-2x4 PT
HOME STUDS OR OTHER
HOUSE WRAP 2x4 STUDS 16" OC CUT TO FIT
EXISTING STRUCTURE2x4 ® 16" OC 0 16' OC
AT 32" OC +/-
I/2" OSB
SHEATHING
WITH I BETWEEN THESE
I 2 3
I/2'
4-1/4X3 SCREWS
TYPICAL EA JOIST TIE PLATE EA STRINGER iv
2x6 FLOOR LINE 2-2X12 PT STRINGER NEW FLASHING
DRILL EXIST SLAB GALV SET IN URETHANE
2x12 TREADS AND INSERT 1/2x12AND TAPCON TO CONCFTHREADEDROD12" OC, AND SCREW
TO PLATE 12' OC
2x6 0 14"OC MAX FINISH GRADE
IS I
24<2R+IT<25 GRADE VARIES
7+7+10.5=24.5 N
h ^ N
Z
NEW FOOTING F
z
m
2X4
L2x2 PLATE WASHER
WITH NUT EACH SIDE
12" MIN
2X4(EA
Lo
JOIST:
PAF @ 12" OC 10 1/2 10 1/2 10 1/2
DETAILS
2-#5
8
4
ANDREW KU
ARCHIT T
5 (4
0 1
3 38
AKU CF .R .COM
El 011
11
PERMIT # //-/ 01; CF
CBUCK, Inc. Florida Certificate of Authorization # 8064
Specialty Structural Engineering
Evaluation Report
Of
Berridge Manufacturing Company
M -Panel"
Metal Roof Assembly
for
Florida Product Approval
FL 11422.9
Florida Building Code 2007
Per Rule 9B-72
Method: 1- D
Category: Roofing
Sub - Category: Metal Roofing
Product: "M -Panel" Roof Panel
Material: Steel
Panel Thickness: 24 or 26 Gauge Min.
Panel Width: 36"
Support Type: Steel Purlins
Prepared for:
Berridge Manufacturing Company
1720 Maury Road
Houston, TX 77026
Prepared by:
James L. Buckner, P.E.
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 08-136-MPanel-36-S6P-ER
Date: 9/l/08
Contents:
Evaluation Report Pages 1 — 6
CBUCK, Inc.
1334 S. Killian Drive, Suite 4, West Palm Beach, Florida 33403
Phone: (561)49.1-9927 Fax: (561)491-9928 Email: ebuck(alcbucldnc.net
James L. Buckner, P.E.
Florida P.E. # 31242
g1nIoa
f
FL #: FL 11422.9
Date: 9/l/08
Report No.: 08-136-Wanel-36-SO-ER
C'B
iT
T
J CK Engineering
Page 2 of 6
CBUCK, Inc. Florida Certificate of Authorization 0 8064
Specialty Structural Engineering
Manufacturer:
Product Name:
Product Category:
Product Sub -Category
Berridge Manufacturing Company
M -Panel" Roof Panel
Roofing
Metal Roofing
Compliance Method: State Product Approval Rule 9B-72.070 (1) (d)
Panel Description: "M -Panel", Steel, Lapped, Roof Panel attached to Steel Purlins.
Panel Material / Standards: Material: Steel
Yield Strength: 40 ksi minimum
Corrosion Resistance:
Material shall comply with the Florida Building Code (FBC), 2007
Section 1507.4.3.
Panel Dimension(s) Thickness: 24 or 26 gauge minimum
Width: 36" Maximum (Net Coverage Width)
Rib Height: 3/4"
Support Type: Steel Purlins
Design of support system is not included in this evaluation)
Support Description: • Thickness: 16 gauge minimum
Yield strength: 55 ksi minimum
Slope Range: Minimum slope shall comply with FBC 2007, including Sections 1507.4.2,
1504.7 and in accordance with the Manufacturers recommendations.
Insulation: (Optional)
Any compressible blanket insulation, thickness = 4" maximum before
compression.
Fire Classification: Fire Classification is outside the scope of Rule 9B-72, and is therefore not
included in this evaluation. Additional approved substrates may be added for
Fire Classification purposes.
FL #: FL 11422.9
Date: 9/1/08
Report No.: 08-136-Wanel-36-SERER
C -BUCK Engineering
Page 3 of 6
CBUCK, Inc. Florida Certificate of Authorization # 8061
Specialty Structural Engineering
Attachment Component Panel to Support Fasteners
Description: Size: #12 -14 x 3/4" minimum penetration through support
Type: Hex -washer Head Self -drilling screws with a neoprene sealing washer
Corrosion Resistance: Per FBC Section 1507.6.6 and 1507.4.4
Standard: Per SAE J78-1979
Panel to Panel, Stitch Fasteners
Size: #12 -14 x 1"
Type: Hex -washer Head Self -drilling screws with a neoprene sealing washer
Corrosion Resistance: Per FBC Section 1507.6.6 and 1507.4.4
Standard: Per SAE J78-1979
Installation: Berridge "M -Panel" Roof Panel Attachment:
Panel to Supports:
Purlin/Support Spacing: 60" o.c. maximum
Fastener spacing: 6" o.c.
along the purlin, adjacent to every corrugation)
Minimum fastener penetration or embedment into supports, 3/4".
Panel to Panel, Stitching:
Sidelap spacing: 12" o.c.
along the length of the side laps)
Install the system in compliance with the attached installation method.
Refer to manufacturer's installation instructions as a supplemental guide for
attachment.
Design Uplift Pressure: -52.5 psf ( Safety Factor of 2 : 1 )
@ maximum purlin spacing = 5'- 0" (Based on 2 or more spans)
FL #: FL 11422.9
Date: 9/l/08
Report No.: 08-136-MPanel-36-S6NER
CBUCK Engineering
Page 4 of 6
CBUCK, Inc. Florida Certificate of Authorization # 8064
Specialty Structural Engineering
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 9B-72.070 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Underwriter's Laboratories, Inc. (FBC Organization
QUA 1743)
Performance Standards: The product described herein has demonstrated compliance with:
UL580-94 — Test for Uplift Resistance of Roof Assemblies—with Revisions
through February 1998
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 2007, Section 1504.3.2
Evaluation Report Scope: This product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code, as related to Rule 9B-72.
System Limitations: The required design wind loads shall be determined for each project per FBC,
2007, Section 1609. Any rational analysis computations shall consider web
crippling and fastener pullout/pullover per AISI Cold -Formed Steel specification
and prepared by a qualified design professional as required by FBC 2007,
Sections 104, 105, 106. The maximum fastener/clip and support spacing listed
herein shall not be exceeded. Diaphragm and axial load capacity is outside the
scope of this evaluation. This report does not evaluate use of this product in the
High Velocity Hurricane Zone.
Referenced Data: 1. UL580-94 (with 1998 Revisions) Uplift Class 90
By Underwriter's Laboratories, Inc. (FBC Organization #CER ID: 1739)
UL File #TGKX.39, Current as of 9/1/08
2. Quality Assurance
Underwriters Laboratories, Inc. (FBC Organization #QUA ID: 1743)
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
FBC Organization# ANE ID: 1916)
FL #: FL 11422.9
Date: 9/1/08
Report No.: 08-136-Wanel-36-SORER
Page 5 of 6
CBUCK, Inc. Florida Certificate of Authorization # 8064
Specialty Structural Engineering
Installation Method
Berridge Manufacturing Company
M -Panel" (24 or 26 Ga. Min.) Roof Panel Attached to Steel Purlins
Profile Drawings
36" Coverage
6"
Typical Panel Profile View
36" Coverage
6" Berridge W -Panel"
7
12 -14 Hex -head Steel Purlins
SD Screws w1 VSW
Typical Assembly Profile View
BUCK Engineerin;"
Specialty Structural Engineering
FL #: FL 11422.9
Date: 9/1/08
Report NO.: 08-136-Wanel-36-W-ER
Page 6 of 6
CBUCK, Inc. Florida Certificate of Authavzation # 8064
Installation Method
Berridge Manufacturing Company
M -Panel" (24 or 26 Ga. Min.) Roof Panel Attached to Steel Purlins
M -Panel 6" o.c. Typical Panel to Purlin Fasteners:
12 -14 Hex -Head SD Screws wMISW
F-6"o.c. adjacent to every corrugation
Fasteners -
Steel Purlins #12-14 Hex -Head
Self -Drilling Screws
Sidelap Stitch Fasteners:
12 -14 x 1" Hex -head SD Screws w/WSW
12" o.c. Along the Length of the Lap
Typical Assembly Isometric View
Optional Insulation: