HomeMy WebLinkAbout121 Bent Oak CtRECEIVED APR 112011 CITY OF SANFORD BY: B_UI DING & FIRE PREVENTION PERMIT APPLICATION 2/ Application No: l I 119 Documented Construction Value: $ ;4-FBB IIA Job Address: t ZI behi' 04k ( Historic District: Yes No Parcel ID: Zoning: ` Description of Work: R-&0LQ.tw4 c4 of W6-\ Plan Review Contact Person: Title:' Phone: Fax: I E-mail: Property Owner Information Name NS Phone: L10 7 • ZZl • O H) Street: r i21- Wyk aResident of property? City, State Zip: P v t 4 C1, 3Z7`73 Contractor- Information Name V A ir-z p_ 0- Ya L, Phone: k0 l- 9 K 7- Street: 2 7 5 - fl 24 h g e Ave- . ` 500- z + Z, - Fax: -10 -7 , l 213 City, State Zip: 000,v\do r—, 32,06 State License No.: c6c_(a53-1o3 Name: Street: Architect/ Engineer Information Phone: Fax: City, St, Zip: E-mail: Bonding Company: Address: Mortgage Lender: Address: PERMIT INFORMATION Building Permit eSquare Footage: Construction Type: No. of Dwelling' Units: Flood Zone: Electrical Plumbing No. of Stories: New Service — No. of AMPS: New Construction - No. of Fixtures: Mechanical ( Duct layout required for new systems) Fire Sprinkler/Alarm No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance- of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to "the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires.payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Print Owner/Agent's Name y r l Date Signature of Contractor/gent Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: Jft L1-11 11 ENGINEERING: COMMENTS: UTILITIES: VI Or k-C // Print Contractor/Agent's Nalne Signature of Notary -State of Florida Date coM r s cfk o anuaryr oy NCO Contractor/Agent is `ei% owXio ge or Produced ID WASTE BUILDING: Rev 11.08 Ethics Construction. CBC1253703 Design, Build and Create 925 SR 434 Winter Springs FL 32708 Gregg Necrason #407/758/5889 nec_rasoru>>mac.comice_ .-- TO DJ Et Kim Medlong IL I (Sent UaK Lt. Sanford Fl, 32773 Hm# 407/330/0243 Cell#407/221/6910 INVOICE # 102 DATE: APRIL 7, 2011 Victor Kelly Cell# 407/947/1228 Fax#407/478/1213 Vkellvl sy_ hoo.com CBC#1253703 Uccupatlonal LICP SUUU-10' ?3" General Liability Insurance Policy# 72740049 I SALESPERSON JOB PAYMENT TERMS DUE DATE j Vic Kelly 121 Bent Oak Ct. Draw Schedule Upon Completion i TURNKEY "MATERIAL AND LABOR INCLUDED" UNIT PRICE LINE TOTAL Tear out existing windows, re -buck all rough openings with pressure 1x4. I Installation of 11 new insulated vinyl windows caulked and sealed i I from inside and out.. ' Permit and inspection will be obtained upon completion. I I + i i I SUBTOTAL $2,180.00 Add 7 % Tax is accounted for, in material supplies only. SALES TAX ji 2,180.00 TOTAL THANK YOU FOR YOUR BUSINESSI Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 f 9!•'.* b'T.s DAVID JOHHNSSOOM CFA. ASA 24 3t2577 :i3 t PROPERTY 2E 40 gs, ` 91 1, S APPRAISER rr S1 YL. SEMINOLE CO+UNTF p3 m 7S33 e `1S SANFORD, FL32771-1466 dg dd 74 ; p r r' wF4 J_ ••• f7sr 407-665-7506 d0 6' d, VALUE SUMMARY VALUES 2011 2010 GENERAL Working Certified Value Method Cost/Market Cost/Market Parcel Id: 11-20-30-505-0000-0300 Number of Buildings 1 1 Owner: HOWELL DARLYNN J & Depreciated Bldg Value 64, 565 70,870 Own/Addr: MEDLONG KIMDepreciatedEXFTValue653 653 Mailing Address: PO BOX952617LandValue (Market) 15, 000 18,000 City,State,ZipCode: LAKEMARYFL32795LandValueAg0 0 Property Address: 121 BENTOAKCTSANFORD32771Just/Market Value 80, 218 89,523 Subdivision Name: HIDDEN LAKEPH3UNIT1TaxDistrict: S1-SANFORD Portablity Adj 0 0 Exemptions: 00-HOMESTEAD (1994) Save Our Homes Adj 0 5,831 Dor: 01-SINGLE FAMILY Amendment 1 Adj 0 0 Assessed Value (SOH) 80, 2181 83,692 Tax Estimator 2011 TAXABLE VALUE WORKING ESTIMATE Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 80, 218 50,000 30,218 Amendment 1 adjustment Is not applicable to school assessment) Schools 80,218 25,000 55,218 City Sanford 80,218 50,000 30,218 SJWM(Saint Johns Water Management) 80,218 50,000 30,218 County Bonds 80,2181 50,0001 30,218 The taxable values and taxes are calculated using the current years working values and the prior years approved millage rates. 2010 VALUE SUMMARY SALES Tax Amount (without SOH): 989 Deed Date Book Page Amount Vacllmp Qualified 2010 Tax Bill Amount: 872 WARRANTY DEED 10/1987 01893 1891 $64,900 Improved Yes Save Our Homes (SOH) Savings: 117 WARRANTY DEED 09/1983 01487 1750 $52,400 Improved Yes 2010 Certified Taxable Value and Taxes DOES NOT INCLUDE NON - AD VALOREM ASSESSMENTS Find Comparable Sales within this Subdivision LEGAL DESCRIPTION LAND Pick... 0- Land Assess Method FrontageDepthLandUnitsUnitPriceLandValuePLATS: LOT 0 0 1. 000 15,000.00 $15,000 LEG LOT 30 HIDDEN LAKE PH 3 UNIT 1 PB 27 PGS 44 TO 47 BUILDING INFORMATION Bid Num Bid Type Year Bit Fixtures Base SF Gross SF Living SF Ext Wall Bid Value Est. Cost New Building 1 SINGLE FAMILY 1983 6 1,262 1,810 1,262 CONC BLOCK $64,565 Sketch 72,955 Appendage I Sqft OPEN PORCH FINISHED / 35 Appendage I Sqft GARAGE FINISHED / 513 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished,Base Semi Finshed EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New ALUM SCREEN PORCH W/ CONC FL 1987 192 653 $1,632 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteadedproperty your next ear's property tax will be based on JusUMarket value. I anq e Concrete or Masonry Opening v a' av: Q V p ' w p Z a Perimeter Caulk, By Others Also between Bonge and buck 0 E 5 0a 00 Head THIS DETAIL FOR HEAD & JAMBS OF FIXED UNITS) UT if Glass as Required flange Type Window Frame Sill Perimeter Caulk By Others ANCHOR Caulk Between Buck and Masonry Opening Wood Buck by Others T 0 M M I s n Outside Dimension — Perimeter Caulk - Jamb Caulk Between Flange and Buck Concrete or Masonry Opening 1-1/4" MIN. PENETRATION d' a: u d d e d v n •a•. c ANCHOR Wood Buck By Others 3 16" ft 16 SHIM 3/4" Caulk Between BUCK Buck and Opening Inside Dimension NOTES 1. Locate anchors within 3" of corner or meeting. rail, as shown. 2. Shim as required at each installation anchor as shown. 3. Anchor must be of a length to have 1 1/4" penetration into masonry or concrete. Install per manufacturers instructions. 4. Caulk joints (Silicone or Urethane) are shown for information only. Carpenter shall insure that wood buck is water tight. Window installer shall insure that window perimeter is water tight 5. If exact window size is not given, use anchor quantity for next larger window in chart. soStool By Others 6. Letter designations on the anchor location chart indicate where p Sill a anchors are to be installed using the elevation as a key. 7. Details shown satisfy requirements for listed structural loads. a .. p a Engineer has not evaluated details for weather or water resistance. p V a a v: Pre -Cost Sill / • p By Others J .a • o ' Caulk Between Flange and Pre -Cast Sill ANCHORS ARE 3/16" HARDENED MASONRY SCREWS SUCH AS ITW TAPCON (ICBO ER-3370), POWERS TAPPER (ICC-ES ER-5878), OR SIMPSON TITEN (FL 2355.1) A B E A C D C SINGLE HUNG SHOWN A B E 3/16" DIA. ANCHOR LOCATION CHART - Single Hung CODE WINDOW ID FASTENER LOCATIONS SIZE SIZE UP TO DP35 DP35.1 TO DP50 12 18 1/8 x 25 A A 13 18 1/8 x 37 3/8 A A 14 18 1/8 x 49 5/8 A, B A, B 15 18 1/8 x 62 A. B A, B 16 18 1/8 x 71 1/4 A, B A. B 1/2 32 25 1/2 x 25 A A 1/2 34 25 1/2 x 49 5/8 A. B AA 1/2 35 25 1/2 x 62 A. B A, B 1/2 36 25 1/2 x 71 1/4 A. B A, B 22 36 x 25 A. D A. D 23 36 x 37 3/8 A, D A. D 24 36 x 49 5/8 A. B, D A, B, D, E 245 36 x 55 1/4 A, B, D A. B. D, E 25 36 x 62 A, B. D A. B, D, E 26 36 x 71 1/4 A. B. D A. B, D. E 32 52 1/8 x 25 A, C. D A, C. D 33 52 1/8 x 37 3/8 A, C. D A, C, D 34 52 1/8 x 49 5/8 A. B. C, D A, 8, C, D, E 345 52 1/8 x 55 1/4 A. B. C, D A. B, C, D, E 35 52 1/8 x 62 A, B, C. D A, 8, C, D. E 36 52 1/8 x 71 1/4 A, B, C, D IA, B. C D. E C O -0 U L O to fn 0) C O N U) t7 10 0 0 to C C O 7 00 v tf) t) tN O 0 d _0 N 0 Ld 11U1IIIIIIIIU//ryr n p;...... moo. 4a 0Na) 001 m 0 0% J z u) _ .Z aw'w:o J za v a 16 g u d ^ o Q. z 0: y .o,lo C n z 1 g Concrete or Masonry Opening I °v 2 Z0 Q Iw q a Perimeter Caulk, By Others Also between 0onge and buck F ead DETAIL FOR JAMBS XED UNITS) ANCHOR S1 D Caulk Between Buck and Masonry Opening D q D Wood Buck by Others q dL) U n03 J m E:lab Lj Tr Class as Required a o C Flange Type Window Frame Sill E Perimeter Caulk IByOthers Outside Dimension — Perimeter Caulk - JambCaulk Between Flange and Buck A Concrete or Masonry Opening 1-1/4" MIN. PENETRATION B E A IJ C G a a d a Al ANCHOR Wood Buck By Others 3/ 16" tl 16" SHIM 3/4" Caulk Between BUCK Buck and Opening Inside Dimension NOTES 1. Locate anchors within 3" of corner or meeting rail, as shown. 2. Shim as required at each installation anchor as shown. 3. Anchor must be of a length to have 1 1/4" penetration into masonry or concrete. Install per manufacturers instructions. 4. Caulk joints (Silicone or Urethane) are shown for information only. Carpenter shall insure that wood buck is water tight. Window installer shall insure that window perimeter is water tight 5. If exact window size is not given, use anchor quantity for next larger window in chart. Stool By Others 6. Letter designations on the anchor location chart indicate where D SIII ° anchors are to be installed using the elevation as a key. 7. Details shown satisfy requirements for listed structural loads. Engineer has not evaluated details for weather or water resistance. n Pre —Cast Sill - a Q° p By Others J o ' Caulk Between Flange and Pre —Cost Sill ANCHORS ARE 3/16" HARDENED MASONRY SCREWS SUCH AS ITW TAPCON (ICSO ER-3370), POWERS TAPPER (ICC—ES ER-5878), OR SIMPSON TITEN (FL 2355.1) C D C SINGLE HUNG SHOWN 3/16" DIA ANCHOR LOCATION CHART — Single Hung CODE WINDOW ID FASTENER LOCATIONS SIZE SIZE UP TO DP35 DP35.1 TO DP50 12 18 1/8 x 25 A A 13 18 1/8 x 37 3/8 A A 14 18 1/8 x 49 5/8 A, B A, B 15 18 1/8 x 62 A. B A, B 16 18 1/8 x 71 1/4 A, B A, B 1/2 32 25 1/2 x 25 A A 1/2 33 25 1/2 x 37 3/8 A A 1/2 34 25 1/2 x 49 5/8 A, B A, B 1/2 35 25 1/2 x 62 A, B A. B 1/2 36 25 1/2 x 71 1/4 A, B A, B 22 36 x 25 A, D A. D 23 36 x 37 3/8 A, D A, D 24 36 x 49 5/8 A, B. D A. B, D. E 245 36 x 55 1/4 A, B, D A. B. D. E 25 36 x 62 A. B. D A, B. D, E 26 36x711/4 A.B.D A,B.D.E 32 A,C,D A,C,D 33 5251/8/x8 3723/8 A. C, D A. C. D 34 52 1/8 x 49 5/8 A, B, C, D A, B, C, D, E 345 52 1/8 x 55 1/4 A, B. C. D A, B, C, D, E 35 52 1/8 x 62 A. B, C. D A, B. C, D. E 36 52 1/8 x 71 1/4 A. B. C. D A, B, C, D. E U 0) O Z3 D U N t L U U C L0) C O 7--, En 0 L0 O to C C O z 5 11 O 1- OO to 0 O U t C u7 3 O OI DN a t7 O d a) 4" 4 dU^co Z'izy H of Lin1.2 O O'. y e ul ' Q q w a p any. z r .p\) og O mignmPiR o° fr n N a o" 3 CONCRETE OR MASONRY BY \ OTHERS v Ii 9 1xr-FD, 3 i i ROUC,H OFENIs C EkIE 13 VraOD FRAYING BY OTHERS 1 1 7/8" LAIN EDGE DISTANCE 1 1/2" MIN. A 4 c EMBEDMENT 3 y1- CUP #5796 INSTALLATION As)CHCR SEE LOCO CAPACITY CHARTI y Tl N !i576a 5764 i t tLLt4i FINSTAUAT ION ANCIAOR 1 ; j 1 (SEE LOAD J CAPACITY CIian) MULLION CLIP #5796 1 1/2" MIN, r EMSEMMENT 5ECTION DESCRIPTION PSr uULUON CLIPI5746 70 DTY. 2) 010 S'WS W/1,5' MIN. EMOEOVENT 5g 2) 110 Sa'S W/1.9' ViN. EMSEO4ENT 70 A) 1410 SINS W/1.5- M:N. EMOECuENT 70 2) 3/16- TAPCONS W/2 1/4' WN. OC. SPACI4C 70 BLIN MQELM JLLL:ti^4 EXTERIOR = EVATIgZj 7/32" DIA, (2) 7/16" f L if 13/116 11 3 Y,t.LLION IP N579.6 IlSN A Vi .j('jQ rRATE ONLY VERTICAL MVP LION DESIGN LOAD CAPACITIES CHART FOR MULLION 5764 y .N > MPAN V 24.000 30 LIM 16.C•CII7.000 42.000 48.000 53125 36. 0w 7a 70 70 70 70 70 70 42. 000 70 70 70 70 70 70 70 48. 000 ff t70 ii70 70 70 70 70 70 50. 625 70 70 70 70 70 70 70 60000 70 70 66 64 53 55 53 61000 70 65 ) 59 57 53 40 46 72. 000 62 51 s4 43 32 35 33 7/ 32" D(A. (4) 2 I/ 21 T " 2 7fiG" Z 7/S" 3/—i 8" ''. o` l ERSI N u 1) T,+E PRODUCT SHOWN HEREIN IS OESIGNED AND MAUFACTUPED TO CO`APLY WITH THE u,!+YIN SP 1FICAnON N07ES. <"004 FLORIDA I4L4LOING CODE. SECTION 171 A.55.. i) CHART APPLES ONLY TO UULUON 5764 WHEN USED '.0 NULL SEMES 2) MULLION Y4SIALLATIO4 CETAILS APPLY TO ALVMINUV TUBE MULLION, OIF, NUMBER 5764, 165. 155. 74D, 3COD, 3185. 3240, 3540 AND 3740 WINDOWS SIDE "EN USED TO MULL WINDOWS SIDE Sy SIDE. 81' SIDE. 1) APPROVED IMPACT PROTECT" SYSTEV 15 REQUIRED ON THIS PRODUCT IN AREAS 2) READ WINDOW WTD,H AND MULL SPAN IN INCHES. REOVIRING IMPACT RESISTANCE. 3) DESIGN PRESSURE VALUES ON THIS CHART ARE PGSINVE AND NEGATIVE PSF. 4) USE 3/16- DIAMETER 7APCDN ANCHOR OF SUFFICIENT LENGTH 70 ACHIEVE A'J-IMLM 4) DESIGN PRESSURE VALUES APPLY TO MULLON WHERE PWO OR HOPE £MBEOVENT OF 1 1/2- INTO MASONRY OR CONCRETE. 3/16- OIAMETER TAPCON INDOWS ARE LISTED IN A SINCLE OPEN N.G. MUST HAVE A 1 7/8' N1NatUM EDGE DISTANCE FROM EDGE OF MASONRY OR 5) REFER TO REPORT 1245 FOR MORE N1P_UON SPECIFICATIONS. ,1 L 1 ; .. r . CONCRETE, Y USE 110 WOOD SCREW 0% SUFFICIENT LENGTH TO ACHIEVE MINIMUM EMOEOUENI OF 111 1/ V INTO W000 FRA.UWG. i rtsI wMtP- 5477 I c-. IQ \-- 1 7/8" MIN. CONCRETE OR i EDGE DISTANCE MASONRY BY OTHERS A+ A j + a 4 4 4 ° 1 1/ 2' MIN. a 46 4 EMBEDMENT I I (: MULLION r = CLIP #5796 INSTALLATION ANCHOR SEE LOAD CAPACITY CHART) M t I N EEERIQE SECTIONS 7 4• ROUGH OPENING XTERI P. WOOD FRAMING BY OTHERS SECTION A MULLION 5 664 INSTALLATION ANCHOR SEE LOAD CAPACITY CHART) MULLION CLIP #5796 1 1/2" MIN EM8EDMENT LOAD CAPACTTI OESCR!P MULLYON CL y10 Sws W/1.5- 1 110 SWs W/I.S- I 110 SWs w/1.5- I 1/16. TAPCONS W, TWIN MULLED A/MULLION #,9764 XTERIOR ELEVATION 7/32" DIA I I MM 3 1 L—_ I MULLION CLIP 5796 VERSION A WOOD SUQSTRATE ONLY) V LLl4N SPECI;ICA71ON NOTES 1) CHART APPLIES ONLY TO MULLION 5764 WHEN USED TO MU1 165, 185. 740, 3000. 3185. 3240, 35 0 AND 37c0 w1ND0 BY SIDE. 2) READ WINDOW WIDTH AND MULL SPAN IN INCHES. 3) DESIGN PRESSURE VALUES ON rr1:S CHART ARE POSITIVE ANI DESIGN PRESSURE VALUES APPLY TO MULLION WHERE TWO C WINDOWS ARE LISTED IN A SINGLE OPENING. 5) REFER TO REPORT %245 FOR MORE MULLION SPECIFICAtIONS DATE II J TWIN MOLI E M2 LION #5764 TFRIOR ELEVATION 7/32" DIA. (2) 7/16" rr- 11 13/16„ II t I 3/8 } MULLION CLIP €5796 VERSION A WO00 SUBSTRATE ONLY I C3An rAPAf:IT1^S r)F ANrunPq OESCR:PTIGN PSF MULLION CLR #5796 70 OTY, 2) 010 SWS W/1.5' MX EMBEDMENT 8 2) 110 SWS W/1.9" MIN, EMBEDMENT 70 4) 10 SWS W/1.5- M.N. EMBEDMENT 70 2) 3/16' TAPCONS W/2 1/4" MIN. G.C. SPACUY• 70 VERTICAL MULLION DESIGN LOAD CAPACITIES CHART FOR MULLION 5764 WJW. HW,0 ? MU L S-m V 24.000 30.0O4 36.000 37.000 42.000, 48.000 53.125 36.000 70 70 70 70 70 70 70 42.000 70 1 70 70 7G 70 70 I 70 48.000 70 70 IIIII 70 I 70 j 70 70 70 50,625 I 70 70 70 I 70 70 70 70 60.000 I 70 I 70 66 t 64 59 55 53 63.0-0 70 68 59 57 53 49 46 72.000 62 51 4.4 43 39 35 33 7/32" DIA, (4) MULLION CLIP #5796 VERSION NOTE: jFL^ATION NOTES; 1) THE 2004 POPRDIOR DA CT H8UIN HEREINNG I SEC ION D1 AND SMSANUFACTURED TO COMPLY WITH THE 11 4PPLIES ONLY TO MULLION 5764 WHEN USED TO MULL SERIES 2) MULLION INSTALLATION DETAILS APPLY TO ALUMINUM TU8E MULLION. DIE NUMBER 5764, 5, 740, 3000, 3185, 3240. 3540 AND 3740 WINDOWS SIDE WHEN USED TO MULL WINDOWS SIDE BY S(OE. INDOW WIDTH AND MULL SPAN IN INCHES. 3) REQUIRING PACT RESIST CE. PROVED IMPACT PRTECTIVE STEM 15 P.EOL9RFD ON THIS PRODUCT IN AREAS PRESSURE VALUES ON TH?S CHART ARE POSITIVE AND NEGATIVE PSF. 4) USE 3/t6- DIAMETER TAPCON ANCHOR OF SUFFICIENT LENGTA TO ACHIEVE MINIMUM PRESSURE VALUES APPLY TO MULLION WHERE TWO OR MORE EMBEDMENT OF 1 1/2"INTO MASONRY OR CONCRETE. 3/16' DIAMETER TAPCON WS ARE LISTED IN A SINGLE OPENING. MUST HAVE A 1 7/8' MINIMUM EDGE DISTANCE FROM EDGE OF MASONRY OR T REPORT 1245 FOR MORE MULLION SPECIFICATIONS. , r , CONCRETE. REVISION I DATE yt.• I y ' USE Ito WOOD SCREW OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM EMBEDMENT OF a` • a 1! )/ " tNiO WOOD FRAMING. Pobrrto Lomas Vil WINDOWS AND DOORS t lk GRATZ, PA. MULLION 5764 FLANGE V83} i J VERTICAL ALUMINUM TUBE MULLION Pul_c eY: DRL 02/02/06 Product Techhology Corjto"t;or. _ — 1150,Le IW' - k 6 !. N.T.S. MIH0065 Winter i t ,fca 32769 t t r r 4 s4EEt: f+tPt C+r;ruat? f wtronxeto KC.2s»5 ala.4cT,aueal. Fos 407,6u615 1 OF i MIP-5457 PEr'I'MIT 11\111 i i ins Engineering Evaluation Report Report No.: WE-2008-178 Evaluator: Robert A. Walz, P.E. Walz Engineering I I I I I Hall Road, Suite 110 Utica, Michigan 48317 Manufacturer: MI Windows and Doors 650 West Market Street Gratz, Pennsylvania 17030 Product: Section 5765 — Series 185 Vertical Flange Mullion OFFICE., Description of Product: Section 5765 — Series 185 Vertical Flange Mullion. The mullion is extruded from 6063-T5 aluminum and used in the vertical orientation in the following window series: 165/185/740/3000/3185/3240/3500 HP/3540/3740. The mullions are secured to the substrate using the 5796 aluminum mullion clip. There are two anchors in each 5796 mullion clip to anchor the mullion to a concrete substrate and four anchors to anchor the mullion to a wood substrate. Submitted Technical Documentation: 1. Mullion Analysis and Anchorage Report, report number WE-2008-178A sealed by Robert A. Walz, P.E. 2. Installation Details, Report Number WE-2008-178D sealed by Robert A. Walz, P.E. Installation Requirements: Mullions must be installed as per the manufacturers published installation instructions and as described in the installation drawings listed in the technical documents section of this report. Mullion Design Pressure Table Section 5765 Vertical Flange Mullion Capacity Height/Width 24" 30" 36" 37" 42" 48" 53-1/8" 72" 70 70 62 61 55 50 47 84" 65 53 45 44 39 35 33 96" 49 40 34 33 30 26 24 Limitations of Use: 1. Maximum product design pressure of +/-70.0 psf. 2. Maximum unit sizes attached to each side of mullion: 53-1/8" wide by 96" high. 3. Units attached to the mullion must have their own product approval. 4. Units may be mulled indefinitely as long as the maximum unit size is not exceeded. 5. Mullion shall be used in the vertical orientation. 6. Product is not rated for use in HVHZ. 7. Product is not impact resistant and requires impact protection when installed in a Wind Borne Debris Region. 8. Design Pressure of mulled units shall be the lesser of the design pressures of the assembly components, the mullion or the individual units. 9. May be installed in wood or concrete substrate as per installation drawing, Report Number WE-2008-1781). Compliance: The above listed products have been shown to demonstrate compliance with the 2007 Florida Building Code and with the Florida Department of Community Affairs for Statewide Product Approval as per Rule 9B-72.070 method 1(d). Robert- Walz, P.L. Florida P.E. 40456 Date; November 6, 2008 CONCRETE BY OTHERS Q is '.. i. _ SECTION B u Ju7SEE INSTALLATION NOTES MULLION CLIP 5795 GH SECT[ QN 5765 ING SECTION c 40- 1— — -- —1 1- , —T MULLION CLIP 57% SEE INSTAL NOTES 7- 1/2- MIN. PENETRAnON TWIN OR TRIPLE MULLED WITH MULLION 5765 r II f to $ a MULLION CLIP #5796 NOT TO SCALE) RS76S V@TICAL MULLION DESIGN ti IPSF1 CiOACITY UNT 24- 30• 1 36' 37- 4Y I 4r 1S 0 • 47 P. 8144.9143,613041N41f 4 {. 1) CHART APPLIES ONLY TO MULLION 3765 MEN USED TO MILL 317RE5 t65/16S/7{0/3000/stBS/3240/SSOOtP/J840/5740 1WNDOYIS SIDE -BY -SIDE 2) MULLION SHALL BE 6063-75 AUXANLI t ALLOY AND TWO 3) WINDOW VADTH 1S MOTH CF RCIVIOWIL VAICOW 4) STATED DESCY PRESSlMES ARE FOR POSITIVE AND NEGATIVE MID 5) MULLION SPANS AND DESCN PRESSiRE4 LISTED N CHART SATISFY 2007 FLORIDA KLOING CODE RECLOVANTS FOR STIIENUK DEFLECTION APO END REACTION ANCHORAGE 6) Wl W IS HOT APPROVED FOR WIND-BORNE DE81RS RE010N15 WATMIT AN APPROVED PROTECTION DEVICE INSTALLED 7) WU TO EVALUATION REPORT W-2006-178 FOR MILLION ANALYSES u, n0 ISTA,,ATlON BIM, 1) NSTALLATON MUST USE MULLION CLIP #5796 2) INSTALL n0 a r WOOD SCREWS WIN MNIMIM 1-1/Y PENETRATION N EACH HOLE OF CLIP (4 TOTAL) 3) INSTALL 1/4• TAPCON SCREn VAIN WWIM 1-3/4• PENETRATION N EACH HOLE OF CLIP (2 TOTAL). W WW OF 2-1/4• ANCHOR SPACING. 4) VOW FRAI" SHALL K SPRUCE -NNE -FIN (O O.42). CONLSIETE SHALL K MNNM M COMPRESSIVE STRENGTH OF F•C-3,OW PSI. 5) INSTALLATION WAIL IS FOR STRUCTURAL INTEOmTY ONLY SECTION A WOOD FRAMING RENtSIDD6 — to BY OTHERS Imam tm, t ainen f. K-t1 M S750 Attu a t a t s to FLANGE MNLLON a as Ar9ulAOIL R6 Engineering Evaluation Report V Report No.: WE-2008-178 JEvaluator: Robert A. Walz, P.E. C'') LO Walz Engineering 1* (0 11111 Hall Road, Suite 110 CZ `' Utica, Michigan 48317 N v CO Manufacturer: MI Windows and Doors S 650 West Market Street L, Gratz, Pennsylvania 17030 Product: Section 5765 — Series 185 Vertical Flange Mullion O LN Description of Product: Section 5765 — Series 185 Vertical Flange Mullion. The mullion is extruded from 6063-T5 aluminum and used in N the vertical orientation in the following window series: 1 0 00 165/185/740/3000/3185/3240/3500 HP/3540/3740. The mullions are I I 1 secured to the substrate using the 5796 aluminum mullion clip. There are Y two anchors in each 5796 mullion clip to anchor the mullion to a concrete substrate and four anchors to anchor the mullion to a wood substrate. Submitted Technical Documentation: 1. Mullion Analysis and Anchorage Report, report number WE-2008-178A sealed by Robert A. Walz, P.E. 2. Installation Details, Report Number WE-2008-178D sealed by Robert A. Walz, P.E. Installation Requirements: Mullions must be installed as per the manufacturers published installation instructions and as described in the installation drawings listed in the technical documents section of this report. i Mullion Design Pressure Table Section 5765 Vertical Flange Mullion Capacity Height/Width 24" 30" 36" 37" 42" 48" 53-1/8" 72" 70 70 62 61 55 50 47 84" 65 53 45 44 39 35 33 96" 49 40 34 33 30 26 24 Limitations of Use: 1. Maximum product design pressure of +/-70.0 psf. 2. Maximum unit sizes attached to each side of mullion: 53-1/8" wide by 96" high. 3. Units attached to the mullion must have their own product approval. 4. Units may be mulled indefinitely as long as the maximum unit size is not exceeded. 5. Mullion shall be used in the vertical orientation. 6. Product is not rated for use in HVHZ. 7. Product is not impact resistant and requires impact protection when installed in a Wind Borne Debris Region. 8. Design Pressure of mulled units shall be the lesser of the design pressures of the assembly components, the mullion or the individual units. 9. May be installed in wood or concrete substrate as per installation drawing, Report Number WE-2008-1781). Compliance: The above listed products have been shown to demonstrate compliance with the 2007 Florida Building Code and with the Florida Department of Community Affairs for Statewide Product Approval as per Rule 9B-72.070 method 1(d). Rabtr A Walz P.E. Florida P.E. 40456 Date: November 6, 2008 CONCRETE BY OTHERS w. i iti SECTION B'- w II II rJLJ SEE INSTALLATION u NOTES MULLION CLIP i 5796 SECTION 5765 SECTION c 40- 1- - -- -7 SECTION A TWIN OR TRIPLE MULLED WITH MULLION 5765 r I• tAHM MULLION CUP /5796 NOT TO SCALE) N CLIP S SEE INSTALLATION NOTES 1 1- 1/2- MIN. PENETRATION WOOD FRAMING I I — BY OTHERS Z tip e! r) r•u3xE F l. il! CiSd Ff3] LF][7 ET9 E3] LSD] E E:)uuL9 IIELA..UlmWuj 1) CHART APPLIES ONLY TO MULLION 3795 MEN USED TO MULL 3ERIES 165/155/740p000/3165/3240/350OHP/3540/3740 WINDOWS SIDE-SY-SIDE 2) MULLION SHALL BE 6053-TS ALUMIMM ALLAY AND MPER 3) WNDOW WIN IS MOTH Or IDIMDUAL WINDOW 4) STATED DESIGN PRE6SURES ARE FOR POSITIVE AND NEGATIVE MO LOADS 5) MULLION SPANS AND DES*$ PRESSURES LISTED IN CHART SATISFY 20D7 rLORIDA KU= CCOE REcAVA NTS !DR sRRENOTN, oEFLECTION AND DO REACTION ANCHORAGE 5) mum tS NOT APPROVED IN WIND-BORNE Grain REGIONS WHOUT AN APPROVED PROTECTION OEMCE INSTALLED 7) REFER TO EVALUATION REPORT RE-2006-178 FOR MULLION ANALYSES W 1 Wl KQT 11 TION Itl 1 1) INSTALLATION MUST USE MULLION CLIP 05796 2) INST uT-1/r PENETRATIONNEACH "M OF (4 TOTAL) 3) INSTALL 1/4• TAPCON SCREWS NTH W MIM 1-3/4- PENETRATION N EACH HOLE Or CLIP (2 TOTAL). MINIMUM Or 2-1/4- AKHOR SPACND. 4) WOOD nIA ING SNIL K SPRUCE -PIE -FIR (G-0.42). CONCRETE SHALL K MINIMUM COMPRES91K STRENGTH Or r'C-3,000 PS. 5) INSTALLATION DETAIL 15 FOR STRUCTURAL INTEGRITY ONLY NOW IIIWV m 14Ma•t7e 1 5765 IIRO1 I6iIIIIIIM AM WITS Validator / Operations Administrator) MI Windows & Doors, Inc. P.O. Box 370 Gratz, PA 17030-0370 Attn: Rick Sawdey Sinojle {-lung - l.aV'jC- AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION OFFICE The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTEDAAMA/WDMA/CSA 101/I.S.2/A440-05 H-R50-1324x1816(52x72) COMPANY AND PLANT LOCATION CODE SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED NO. DESCRIPTION MI Windows - Salisbury, NC MTL-1 MI Windows - Gratz, PA MTL-2 3500 HP SH (FLANGE) FRAME SASH MI Windows -Van Alstyne, TX MTL-5 PVC)(O/X)(IG)(INS GL) 1324 mm x 1816 mm 1273 mm x 892 mm MI Windows - Lebanon, IN MTL-11 REINF)(TILT)(ASTM) 4'4" x 6'0") 47' x 2'11") 2. This Certification will expire June 25, 2012 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Architectural Testing, Inc. Report No.: 84052.01-109-47 Date of Report: July 9, 2008 Date: September 19, 2008 Cc: AAMA JGS ACP-04 (Rev.8/06) Validated for Certification h' 4;_ A4ocidLaboratories, Inc. Authorized for Certification i Sri.-...... 5' American Architectural ManufactGrers Association ELEVATION 52" 6" typ. 6" typ. Anchor See Section Details) N r, 1' MINIMUM PENETRATION A-:'k'CLEARANCE ALL FOUR SIDES) by others) Caulk between flange and buck perimeter. I '.;I by others) Caulk between flange and buck perimeter. by others) Caulk between flange and buck perimeter. HEAD DETAIL SHEATHING/OSD SIZE HEADER AS NEEDED CAULK UNDER NAILING FIN ENTIRE PERIMETER BEFORE FASTENING. 1" MINIMUM PENETRATION I 8 X 1-1/4" SCREW MUST ACHIEVE 1-1/4" PENETRATION INTO STUD. TYPICAL) SILL DETAIL Notes: 1. Installation depicted based off of structural test report # 84052.01-109-47. 2. Wood screws shall satify the National Design Specification for Wood Construction for material type and dimensional requirements. 3. Wood buck installations are assumed 2x S—P—F (G=0.42) or denser. Buck width shall be greater than the window frame width. Tapered or partial width bucks are not allowed. Wood buck shall be secured to the structure to resist all design loads. 4. Screw lengths shall be sufficient to guarantee 1" penetration into woad buck. 5. Maximum shim thickness of 1/4" permitted at each fastener location. Shims shall be load bearing, non — compressible type. 6. These drawings depict the details necessary to meet structural load requirements. They do not address the air infiltration, water penetration, intrusion or thermal performance requirements of the installation. 7. Installation shown is that of the test window for the size shown and the design pressure claimed. For window sizes smaller than shown, locate jamb fasteners 6" from comers and one at mid —span. Locate head fasteners 6" from comers. Design pressures of smaller window sizes are limited to that of the test window. SIZE AND DESIGN PRESSURE CHART FASTENER TYPE AND SPACING SHOWN WILL ALLOW DESIGN PRESSURES UP TO +50.16 / -50.16 UNITS UP TO 52' x 72" SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN PRESSURE LIMITATIONS) SHEATHING Mi TAL•WAVX BY: DAM INSTALLATION INSTRUCTIONS T.C. 10/2/08 FASTENER SCHEDULE - FLANGE- °EOM DA7E JAMB DETAIL Prim SUIE: 9EET: Windows &doors 3500HP Single Hung NONE 1 - 1 BR na Bcv Gratz, PA 3500HP SH FL .— 1. --It 6 . . Validator / Operations Administrator) MI Windows & Doors, Inc. P.O. Box 370 Gratz, PA 17030-0370 Attn: Rick Sawdey ICI i -ed h I aS / -/ ptc AAMA CECERTIFICATIONPROGRO AUTHORIZATION FOR PRODUCT CERTIFICATION k //—/!f/ The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTEDAAMAIWDMA/CSA 101/I.S.2/A440-05 FW-055-1524x2032 (60x80) COMPANY AND PLANT LOCATION CODE SERIES MODEL & PRODUCT MAXIMUM SIZE TESTED NO. DESCRIPTION MI Windows - Salisbury, NC MTL-1 MI Windows - Gratz, PA MTL-2 3500 HP PW (FLANGE) FRAME PVC)(0)(IG) 1524 mm x 2032 mm MI Windows -Van Alstyne, TX MTL-5 INS GL)(ASTM) 5'0" x 6'8") MI Windows - Lebanon, IN MTL-11 2. This Certification will expire June 27, 2012 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Architectural Testing, Inc. Report No.: 84073.02-109-47 Date of Report: July 7, 2008 (Revised July 15, 2008) Date: July 16, 2008 Cc: AAMA JGS ACP-04 (Rev.8/06) Validated for Certification A4ocidLaboratories, Inc. Authorized for Certifi:77 fAmerican Architectural Manufacturers Association 1 r+ ELEVATION 60" 4" typ. J 11" O.C. max. 4" typ. ii 14" o. c. / max. / 1 Anchor See Section Details) 0 W 1 1/4" MINIMU PENETRATION J'""CLEARANCE— ALL FOUR SIDES) by others) Caulk between flange and buck. Caulk around perimeter. by others) JAMB DETAIL HEAD DETAIL Notes: 1. Installation depicted based off of structural test report # 84073.02-109-47. 2. Wood screws shall satify the National 2X BUCK AS REQUIRED Design Specification for Wood Construction for material type and by others) dimensional requirements. Caulk around perimeter. 1 1/4" MINIMUM 3. Wood buck installations are assumed 2x PENETRATION S—P—F (G=0.42) or denser. Buck width shall be greater than the window frame width. Tapered or partial width bucks Caulk between are not allowed. Wood buck shall be flange and buck. by others)WIN% X 1-1/4" SCREW secured to the structure to resist all T ACHIEVE 1" PENETRATION design loads. STUD. YPICAL) 4. Screw lengths shall be sufficient to guarantee 1-1/4" penetration into wood buck. Extarlor 5. Maximum shim thickness of 1/4" permitted at each fastener location. Shims shall be load bearing, non — compressible type. by a Caulk flange or Caulk per by otners) SHIM AS REQUIRED DRYWALL SILL DETAIL 6. These drawings depict the details necessary to meet structural load requirements. They do not address the air infiltration, water penetration, intrusion or thermal performance requirements of the installation. 7. Installation shown is that of the test window for the size shown and the design pressure claimed. For window sizes smaller than shown, locate jamb fasteners 4" from comers and no more than 14" on center. Locate head fasteners 4" from comers and no more than 11" on center. Design pressures of smaller window sizes are limited to that of the test window. SIZE AND DESIGN PRESSURE CHART FASTENER TYPE AND SPACING SHOWN WILL ALLOW DESIGN PRESSURES UP TO +55.17 / -55.17 UNITS UP TO 60" x 80" SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN PRESSURE LIMITATIONS) 0 INSTALLATION INSTRUCTIONS FA TENER SCHEDULE — FLANGE— PaooucD V.M.R. 10/2/08 00M. DATE 3500HP Picture Window suue sixr NONE 1 a- 1 Windows & Doors Gratz, PA 5/0 x 6/8) mrc is' my 3500HP PW FL — V