Loading...
HomeMy WebLinkAbout289 McKay Blvd (3)i CITY OF SANFORD PERMIT APPLICATION Application # : //^ l yY0 Submittal Date: Job Address: 910 y) /C4 L - FL 3x7"71 Value of Work: S 31( - S 6 Parcel ID: f 3/- sZi7' 6606 - Zoning: Historic District: a r Description of Work: r `» qr c90 p Kk Square Footage: Permit Type: Buildin Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Q? Sign Electrical: New Service - # of A Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential Commercial Occupancy Type: Residential Commercial Industrial Occupancy Use Group(s): _ Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) r) O l U Cr— Contractor: Property Owner: M • Address: ( /0" G ICr C / - Addrenss: l - 'e7 r L Y""Y Phone:707-q3Z- QYE-mail: Phone: WO? 170 •J'WigState License Number: C Bonding Company: a I I Mortgage Lender: N f 10 6 ' Address: Architect/Engineer: Address: ""Oe_ i Plan Review Contact Person: v .Scsc fC Address: Phone: Yx7- Z -I 'E-/ oS 7z..gd`7 Fax: y67— 2-'7-!5;_z / 2f S Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts; state agencies, or federal agencies. Acceptance of permit is ver' cation that I will notify the owner a propert of the req u erne s of Florida Lien Law', FS 713. x -..=— V 'Lro 4l Signature of Owner/Agent Date Signature of Contractor7/Agent Date 3, /1 'SS>r P nXvKrri c Ili amyl "I Print Coat1 ctar/Asents_Name Si YT P(f. I,V-.r , - Christopher M D'Angelo r; My Commission D0674759 Expires 0511512011 _ Owner/Agent is _ Produced ID Known to Me or APPROVALS: ZONINGtU(4AG 5' )N'YUTIL Special Conditions: Rev 07.07 01 Contractor/Agent is Produced ID AllFD:ENG: of W •' WNotary Public State of Florid, Christopher M D'Angelo My Commission DD674759porno piresCl,5/2011 BLDG: Seminole County Property Appraiser Select by Owner Page 1 of 1 TA 09FAiL ElAr-K > GENERAL SALES Parcel Number, 31-19-31-527-0000-0580 Owner. RODRIGUEZ ERVIN & Sales Code Deed Type Sales Date Book Page VacanYlmprove SO SW 0712004 05412 1090 I Address: 289 MC KAY BLVD SU CR 07/2004 05395 1084 V Tax District. S1-SANFORD SU WD 02/2004 05209 1033 V Just Value: $91,231 o—m J ruon,CF A,AEA TAX ROLL FOR 2010 PROPERTY Millage Code Millage Description Assesed Exemption Taxable Rate Tax Bill APPRAISER, 0400 SCHL SCHOOL $91,231 $0 $91,231 78010 $711.69 SEMINMECOUNT: 1200 SJWM $91,231 $0 $91,231 4158 $37.93 Nenerora FL 32771 0100 COUNTY GENERAL FUND $91,231 $0 $91,231 48751 $444.76 40 Ws? 9800 COUNTY BONDS $91,231 $0 $91,231 1700 $15.51 r 1000 CITY SANFORD $91,231 $0 $91,231 68250 $622.65 Tax Bill $1,832.54 DOES NOT INCLUDE "NONAD VALOREMASSESSMENTS - LEGAL DESCRIPTION LOT 58 CEDAR HILL REPLAT PB 63 PGS 96 97 & 98 BACK 71611E C6r4TACT pp.. a'7j_W C ll;lt MEs fi@ TRYST ,- M http://www.scpafl.orglweb/tr web.rec detail?parcel=31193152700000580&ctdonly=&ctd=... 5/9/2011 el OWNER ADDRESS TITLE HOLDER ADDRESS CONTRACTOR ADDRESS JOB NAME JOB ADDRESS COUNTY LEGAL DESCRIPTION TAX. FOLIO # BONDING CO ADDRESS ARCHITECT ADDRESS MORTGAGE LENDER ADDRESS APPLICATION FOR BUILDING PERMIT LIEN LAW REQUIREMENT city State Zip CHAMPAGNE POOLS OF C'LICENSE# c:Er 25S7 5497 BENCHMARK LANE STE ;100 City, ' SANFORD State FL Zip 32773 City State Zip C I• • Application is hereby made to obtain a permit to do work and Installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONING, ETC. OWENRS AFFIDAVIT: I hereby certify that all the foregoing information Is Accurate and that•all work will be done In compliance with ill applicable laws regulating construction and inning. NOTICE OF COMMENCEMENT WILL BE POSTED ON THE JOB SITE WITH PERMITS.' WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER AND/OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ACCEPTANCE OF PERMIT IS VERIFICATION THAT I WILL NOTIFY THE OWNER OF THE PROPERTY OF THE REQUIREMENTS OF FLORIDA LIEN LAW SIGNATURE_ OWNER STATE OF FLORIDA COUNTY OF Su cribed and s rn before me this 2day of 2004 who is personally known to me or has proded.c ccs 7 k:, SIGNATU STATE OI COUNTY subscribed and swo before a this day of ,r ` 20# by Who is pe produce as hkfitil 1iil to me or has printed na&e of Notaiy - printed t6ime of Notary v a Notary •,otic State otFlorida se8 `F Christopner M D'Angelo ( seal) 0• °!" votary Public StL11gl lorida My Commission DD674759 Christopher M D' o r° R Ex nes 0 511 51201 1 , ¢o' My Commission 759 ires05/15/2 CERTIFICATE OF COMPETENCE HOLDER: Contractor's state Certification of Registration # g v L ZcUCIGLSv 2ii= Z, pp., 'ZI& W .C1rrC L F,?YJ 2 Ll PIA ff it Q drip I I have reviewed and I give my approval to proceed with the construction of this project. X Customer Signature Date A/0 NAME: ICo0'ZC iySC Z ADDRESS: Co2b STATE: PHONE: ZIP: 1 WORK: CELL: L1 Cj 7_ Li'3j Z - JOB#. EXiSIING HOME: BUILDER INFO: _ NAME: SUPER: PHONE: _ PAGER: JOB NOTES: POOL SPECS, SIZE: 1.2 .24 — SQFT.' DEPTH:PERIMETER: gyp EST TOTAL GALLONS: SKIMMERS: LLj INTERIOR MATERIAL:y`_G I TILE: — NOTES: LIGHTS IN POOL: _ — 0 TOTAL PIPE: 1 SQFT: _ DEPTH: e SPILLWAY: RAISED HEIGHT: - SKIMMERS: RETURNS: _ TILE: - u INTERIOR MATERIAL: MATERIAL 1: SPECIAL: - ------ S mac r I Ll PIA ff it Q drip I I have reviewed and I give my approval to proceed with the construction of this project. X Customer Signature Date A/0 NAME: ICo0'ZC iySC Z ADDRESS: Co2b STATE: PHONE: ZIP: 1 WORK: CELL: L1 Cj 7_ Li'3j Z - JOB#. EXiSIING HOME: BUILDER INFO: _ NAME: SUPER: PHONE: _ PAGER: JOB NOTES: POOL SPECS, SIZE: 1.2 .24 — SQFT.' DEPTH:PERIMETER: gyp EST TOTAL GALLONS: SKIMMERS: RETURNS: r INTERIOR MATERIAL:y`_G SPECIAL: _ TILE: — NOTES: LIGHTS IN POOL: _ — SPA SPECS 6,1 TOTAL PIPE: SIZE: SQFT: _ DEPTH: PERIMETER: ESTTOTAL GALLONS: SPILLWAY: RAISED HEIGHT: - SKIMMERS: RETURNS: _ TILE: - u INTERIOR MATERIAL: MATERIAL 1: SPECIAL: - ------ NOTES: NOTES: PLUMBING RETURNS: . -_ SKIMMERS:—i POOL MAIN DRAINS: -- SPA MAIN DRAINS: cv_ u CLEANING SYSTEM:. HEADS: rJ is - VAC LINES: _ ,_--(E"5 ROBOT VAC: WATERFEATURES:SI1 j2 AL{, SPA SPILLWAY:. LIGHTS IN POOL: _ — LIGHTS IN SPA: - TOTAL PIPE: SPECIAL: - ------------_ NOTES: DECK DECK TYPE:R -]t_ ?(•A [_ ELEVATION: TOTAL DECK SQFT: 4153 . PERIMETER: RAISED BEAM: LIP STYLE: MATERIAL 1: MATERIAL 2: SPECIAL:- NOTES: EQUIPMENT POOL PUMP: — f--'- SA 2ND PUMP: FILTRATION:-(C) s_ R SIZE: HEATER:sCj E: -{( r ;J - TIMER: _ GAS: SPECIAL: NOTES: CD# DESCRIPTION DATE c ITj FA I • ilk I Rodriguez, Ervin 289 Mckay Blvd Sanford 32771 Permit Office: Sanford 407-432-2234 Cedar Hill Entry Code: Access & Dig Type Dig ?I Dig and Haul IDirt'Rmvl? DESCRIPTION DATE IS C.O.# Deck Edge Type Tree Removal ? 12 X 24 Stump Removal ? 3 X owner Plant Removal ? = _- -- 230 Concrete Removal? sgft Owner Saw Cut ? ; ' ' ;i Lft '.. {, Owner TOTALS perimeter 63 area 230 Owner Total Lft 6 Owner Sprinkler System Capped Off ? j"' '' ' ' Owner Sprinkler System Reinstalled ? r =; owner Sod Removal ? 3/4 Owner Barrier or H.P. BARRIER FENCE? No Lft 0 ALUMINUM POST COLOR ? H.P. MESH COLOR ? H.P. ALARM SYSTEM ? 0 Homeowner must be present for final Co. inspection Jandy CS100 Window Glaze ? Main Drains - DESCRIPTION DATE IS C.O.# Pool Light White Pool Grout ColorWhite'. Install Cut Ins For Rope & Float Hooks EMEM Spill Over Type 2" Main Drains White 3' apart Spa Light Color Spa Light White Therapy Jets Air Blower No Pre Plumb Jets Heater Type j-DECKLNG J, Deck Edge TypePOOLSIZE12X24 POOL DEPTH 3 X 6 POOL perimeter 63 area 230 SPA perimeter area Sqft Fountain perimeter area Paver Boarder - This is Included in Sqft Above TOTALS perimeter 63 area 230 Swim Outs # 1 Total Lft 6 Steps Lft 17 SunShelf Sqft 22 Pool Gallons 7,763 Pool Equipment Timer w/remote PUMP TYPE Jandy 3/4 H.P. FEATURE PUMP? ( H.P. FEATURE PUMP? ( H.P. FEATURE PUMP? ( H.P. FEATURE PUMP? ( H.P. Filter Type ( ) Filter Type ( 1 ) Jandy CS100 Automation Std. Timer Only Main Drains - White 4' apart Skimmer 1 White Returns 5 White IN FLOOR Pool Light Color (1) 100 FT Pool Light White Pool Grout ColorWhite'. Install Cut Ins For Rope & Float Hooks EMEM Spill Over Type 2" Main Drains White 3' apart Spa Light Color Spa Light White Therapy Jets Air Blower No Pre Plumb Jets Heater Type j-DECKLNG J, Deck Edge Type Concrete Deck 453 Sgft Existing Lanai_ SqftCopingLftPlanters23Sqft Pavers Thick or Thin Sqft Existing Patio Thick or Thin Sqft Pool &Patio Total Including Sqft Paver Boarder - This is Included in Sqft Above Lft. Deck Drains I Deck -O -D 40 Lft Raised I.D. Beam At 6" Increments Lft Tile Notes For I.D. ` Step Risers At 6" Increments Lft Riser Info Cantilevered & Tile All Risers Turn Downs 10" Lft 1 6,. Lft 22" Lft 8" Screen Footer Lft Pilasters M2-EM-11 WE IMM • Chemical service for 1 Months Pool Cleaner Type Hayward Pool Vacuum Chlorinator Type Autopilot (Cubby) 36 Manual Vacuum, Telescopic Pole, Leaf Net Brush, Water Test Kit & Start up Chemicals Hand Rails- Fig 4 No Other Fountain Spill over Light Sconce? _ Heat Pump SQ110 Elect Run . R Solar Panels # _ Set & Forget Controls Size Booster Pump by Solar Co. Water Surface Solar Cover r J a tl e 3 PERMIT # 434 L J, G V+ S c Qo I -\ d• W W 40 s X9°50'24" E 105.00' a __5_' D RAIi, GE & UTILITY EASEMEN T iO 52.08' 1 yTY. CONC. SLk/5TOCCO R1:5. FF. ELEV = 32.96 41 CD 0 c0 - Y.. G, 4.35'- A _ I x a' 00 4.34' j o 2.7.81:- _ 32.05' J AINAGE & UTILITY EASEMENT T(0'2 4 12 E 105.00' OFFICE t O 0 z Ln cz LIJQ U En 5 25.d8' p O r— Coin; cn C) D2l E LI J 1 L V! ----- a 4 2 57 d CITY OF SANT OI17 BUILDING pLqN6EaIEW SCALE: 1 9J = 20 ? ' PLANNING AN bFVEL®PMENT SERVICES APPROVED DATE SURVEY NOTES: 1) The street address of the above-described property is 289 McKAY BOULEVARD. 2) The above-described property lies in a Flood Zone X per FIRM 12117C 0065E dated APRIL 1995. SURVEYOftj'S CERTIFICATE This is to certiry that I have made a Survey of the above described property and that the plat hereon delineated is an accurate representation of the same. I further certify that this Survey meets the Ki.nimua Tectvii.cal Standards set forth by the Florida Board or Land Surveyors pursuant to Section 427.027 of the Florida Statutes. REVISIONS:/%- REYI5E0 FOR FOONDA-no N, 22 MAR.2004- l.l wfc;r-nrAa HNAl.900GY. 22 JUNE 2004 tI-f atrn ^ior-it rrvTiir- TIIt FIED CORRECT T0: cornu onn01r111=7 OFFICE Permit # PERNII'f Residential Swimming Pool, Spa and Hot Tub Safety Act Notice. of Requirements I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at 9 %L, n/o, fit-, -and hereby affirm that one of the following p,eau Nnt Address) 3aZ7-7 / methods will be used to meet the requirements of Chapter 515, Florida Statutes. please initial the method(s) to be used for your pool) The pool will be isolated from access to the home by an enclosure that meets the pool barrier requirements of Florida Statute 515.29; The pool will be equipped with an approved safety pool cover that complies with ASTM F1346-91 (Standard, Performance Specifications 'for Safety covers for Swimming Pools, Spas and Hot Tubs); All doors and windows' providing direct access from the home, to the pool will be equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at 10 feet; All doors providing direct,access from the home to the pool will be equipped with self-closing, self -latching devices with .release mechanisms placed no lower than ' 54" above the floor or deck; I understand that not having one of the above installed at the time of final inspection, or when the pool is -Completed for contract purposes, will' constitute a violation of Chapter 515, F.S. and will be considered as committing a misdemeanor of the second dpgree, punishable by . fines up to, -$500 and/or up to 60 days in jail as established in Chapter 775, F.S' 4 r C TRACTOR'S SIGNATURE & DATE OWNER'S SIGNATURE & DATE Michael'D. Manley,_ 7g //(/ 5 0_:Z>R/ , —/-- Z, CONTRACTOR'S NAME (PLEASE PRINT) OWNER'S NAME (P EASE PRINT) ion and Operation Data Installation and. Operation Manual Jandy(3 Single Element Cartridge Pool and Spa Filters CS Series Filters PERMIT # r l A WARNING FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/ Spa service technician. The procedures in this manual must be followed exactly. Improperinstallationand/or operation can create dangerous high pressure which can cause the filterlidtobeblownoff, possibly causing death, serious injury or property damage. Improperinstallationand/or operation will void the warranty. Before installing this product, read and follow all warning notices and instructions thataccompanythisfilter. Failure to follow warning notices and instructions may result inpropertydamage, serious injury, or death. dN..7 Cartridg_: Filters - CS Series Filter Page 5 Section 2. , General Informati 2.1 Introduction I'his manual contains information for time proper instal- lation and operation of the Jandy'3 CS Cartridge Filters. Procedures in this rnanual must be followed exactly. 1-6 obtain additional copies of this manual contact us 1t 707.776.8200 ext. 237. For address information see 5 back cover. 2.2 Description Cartridge filters do not require sand or diatomaceous earth its time filter medium. Instead they contain a filter cartridge element which is easily removed for cleaning or replacement. Dirty water flows into the filter tank and is directed through the filter cartridge. The debris is collected on the surface of the cartridge as the water flows through it. The water will travel through the central filter core towards the bottormm of the filter into the lower manifold, Clean water is returned to the swimrning pool through the filter outlet port at the tank's bottom As debris collects in the filter, the pressure will rise and water flow to the pool will diminish. The filter cartridge must be cleaned when the operating pressure of the filter• rises 10 psi fi-om-thc operating pressure of a clean cartridge (see Section 6 "Cleaning the Filter"). NOTE A, filter removes dirt and other suspended particles but does not sanitize the pool. Pool water must be sanitized and chemically balanced for clear water. The filtration system should be designed to meet local health codes. At a minimum, the system should turnover the total volume of water in your pool t..vo to four times in a 24 hour period. 2.3 General Requirements I. l'or best overall performance place the system as close to the pool as pnssible. l-hc filter should be located on a level concrete lab so that the orientation of the valve outlets and time pressure gauge are convenient and accessible Vor the installation and operation of the unit. Protect the filter Ironi the tA,cathcr flitting a chlorinator and/or any other device into the filtration plumbing circuit, great care must be exercised to ensure that the appliance is installed in accordance %vith the Manufacturer's Instructions find Finy applicable standards that may exist. WARNING The maximum operating pressure for this filter is 50 psi. Never subject the filter to operating pressure exceeding 50 psi. Operating pressures above 50 psi can cause the lid to be blown off, which can result in death, serious personal injury, or property damage. Use Jandy universal unions to connect each component of time water conditioning system for future servicing. All Jandy filters come with these type of fittings. 6. 1Vhen performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system, ensure that the maximum pressure the filtration system is subjected to does not exceed the ma--ci/nu//r working pressure of any of the Components within the system. 2. el. Specifications and Dimensions See Table 1 and Figures 1 and 2. Table 1. Cartridge Filter Specifications Filler Area (ft') 100 150 200 250 Max. Flo%y (gpm) 100 125 125 125 Six Hour Capacity (gal.) 36,000 45,000 45,000 45,000 Eight Hour Capacity (gal.) 48,000 60,000 60,000 60,000 Normal Start Up Pressure psi) 6-15 6-15 6-15 6-15 Max. Working Pressure (psi) I 50 50 50 50 Dimension "A" 1 32 3/8" 32 3/8" 42 1/2" I - 14 3/4" __ I I O ' i i/ gill6!r I i t 181/2- F— Figure 1. Dimensions. CS Cartridge Series Filter Tandy. Section 10. Head Loss Curves 10,1 Jandy-O Cartridge Filter, CS Series OV b Design Head Loss ft head) 4 2- CS150 CS200 IiCS250 I CS100 L 0 30 60 90 120 Flow Rate (gpm) J i Design Pressure 2 Drop psi) 1 0 Fuge *14 Section 10. Head 'Loss Curves 10.1 Jandy® Cartridge Filter, CS Series E Design Head Loss ft head) 4 2 CS150 CS200 CS250 F = CS 100 30 60 90 3 Design Pressure 2 Drop psi) 1 0 120 Tandy HAYWARIJ'Po'ol Products A Hayward Industries, Inc. Company Piq:ISDUALSWG Rev: D Owners Manual OWNER'S MANUAL INSTALLATION, OPERATION, a PARTS DUAL SUBMERGED SUCTION OUTLET SET Commonly called main drains] Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe injury and/or death. AThis is the safety -alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury. AWARNING warns about hazards that could cause serious personal injury, death or major property damage and if ignored presents a potential hazard. ACAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards. A - WARNING- - Read and follow all instructions in this R- Q owner's manual and on the equipment. Failure to follow instructions can cause severe injury and/or death. IMPORTANT SAFETY INS'T'RUCTIONS USE ONLY HAYWAFID GENUINE REPLACEMENT PARTS KPIHANWARDPonciPrcaucis v Page 2 of 8 DUAL SUCTION OUTLET SET ISDUALSWG REV D A WA.RNEXG - Suction Entrapment Hazard. Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or unsecured can cause severe injury or death due to the following entrapment hazards: Hair Entrapment- Hair becomes knotted or snagged in an outlet cover. Limb Entrapment- A limb sucked or inserted into an opening of a circulation outlet with a broken or QWmissing cover in the pool resulting in a mechanical bind or swelling Body Suction Entrapment- Suction applied to a large portion of the body or limbs resulting in an entrapment. Evisceration/ Disembowelment Entrapment- Suction applied directly to the intestines through an unprotected sump or suction outlet with a missing or broken cover. Mechanical Entrapment- Potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of an outlet or cover. To Reduce the risk of Entrapment Hazards: o A minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3') [.91 meter] apart, as measured from suction pipe center to suction pipe center. (See Diagram 1. If suction outlets are to be located closer then three feet (3') [.91 meter] apart, they shall be located in different planes (i.e., one on the bottom, and one on the vertical wall, or one on each of two separate vertical walls.) (See Diagram 2) o Dual suction fittings shall be placed in such locations and distances to avoid "dual blockage" by a user. o Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. o The maximum system flow rate shall not exceed the flow rating of any listed (per ASME/ANSI A 112.19.8M-1987, ASME Al 12.19.8-2007, APSP-7) suction outlet cover installed. o Keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material. o Never use a Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. o Prior to each use of the swimming pool and/or spa, observe and replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. o Remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets. o Two or more suction outlets per pump should be installed in accordance with latest APSP Standards and CPSC guidelines. Follow all National, State, and Local codes applicable. o Multiple layers of protection are available including installation of a vent pipe system, a gravity flow system, or a vacuum release system. o Suction outlet components have a finite life, the cover/grate should be inspected frequently and replaced at least every seven years or if fOUnd to be damaged, broken, cracked, missing, or not securely attached. o Do not exceed maximum flow rate stated on suction fitting. c Only -replace a pump with one with a similar flow curve, avoid a pump with a higher horsepower rating. n HAMAR D Poel Prcet.ct5 Page<3 of F _ DUAL SUCTION OUTLET SET ISDUALSWG REV D RECOMMENDED SYSTEM SPECIFICATIONS: ACCEPTABLE PIPE SIZE FOR MAXIMUM RECOMMENDED SYSTEM FLOW RATE PER APSP-7 6 FT/SEC 1N THE BRANCH LINE) o.s Pipe Size Flow rate Pipe Size Flow rate 1 mm] GPM [mm] GPM [Liter[Min] 15 Liter/Min] z •2 1 %2" 40 2 %2" 90 E -z.s 50] [150] [75] [340] s 2" 63 3" 138 s.s 63] [240] [90] [522] a a.s Chart 1 GPM Flow COVER IN 2" SUMP 00 JJ I V5 11.J 125 COVER ONLY Flow Vs Pressure Drop WGXI048E Suction Outlet Covers are rated for Floor Only at 125 GPM FIG 1 Note: ]" Hg= 1.13 Ft ofHeed WGI 048EW Suction Outlet Covers are rated for Wall or Floor at 72 GPM In the event of one suction outlet being blocked, the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system. Example: In the System shown in Diagram 1, two (2) "Floor Only" suction outlet covers are selected and mounted. These covers are individually rated for 125 GPM. For a desired flow rate through the pump of 100 GPM, a minimum pipe size from the Chart 1 is selected at 3". At the desired flow of 100 GPM one cover could be partially blocked and the other suction outlet flow would be below the rated 125 GPM of the "Floor" mounted suction outlet cover. Since there are two outlets flowing in normal operation, and the allowable velocity in the interconnecting piping is only 3ft/sec, the same pipe size is required in the interconnecting piping. Example: In the System shown in Diagram 2, one (1) "Floor Only" suction outlet cover, rated at 125 GPM, and one (l) Wall or Floor" suction outlet cover, rated at 72 GPM are selected and mounted. For a desired flow rate through the pump of 50 GPM, a minimum pipe size from the Chart 1 is selected at 2". At the desired flow of 50 GPM either cover could be totally blocked and the other suction outlet flow would be below the rated 72 GPM of the wall mounted suction outlet cover. Note: Flow may be limited by entrapping force in dual suction systems. Minimum distance 3 feet Pipe Centerlines) Floor Outlets. Total system rated flow 125 GPM Interconnectingi piping System Branch piping Diagram 1 HA AR® Pool Products Dual Outlets ora Diffet-ent Planes Clevatimi or Play Victiv) Total System rated flow 72 GPM 125 GPM Rated Floor Wall 72 GPM rated Interconnecting piping System branch piping Diagram 2 Page 4 of 8 DUAL- SUCTION OUTLET SET ISDUALSWG REV D INSTALLATION INSTRUCTIONS: - Use a #2 Philips head Screwdriver. NOTICE: When installing WG1030AVPAK2 refer to ASME Al 12.19.8-2007 for the proper instructions on how to construct the field -fabricated sump. Figure 2 is an illustration of some of the requirements. Suction outlets for a pool with a vinyl liner and for fiberglass pools are provided with a WG1048B mounting ring and two (2) gaskets. The gaskets should be placed such that they sandwich the liner or fiberglass, that is, one gasket on each side. The ring (WG1048B) is attached to the suction outlet by eight (8) screws that pass through both gaskets and the liner. See diagram below. SELF TAPPING SCREWS GASKET g3 j /•- POOL o ..et. • . _LINER GASKET S, BODY Suction outlets for a concrete or gunite pools are designed to be plastered with the top surface flush to the pool surface, An Adjustable Collar WG1051X may be used to aid in obtaining the desired configuration. Two screws MUST be used to secure the cover to the suction outlet. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS TNICLUDING THE SCREWS. Fig, 2 Field Built Sump C 6tht:'d kOiiS: Si f = FltiCP C i11Pi"<0: Cj•Y. Ftl 1 7 neirots s'+:r.•n;;e r timems i ka<age9fG;TpU.`lI Ycn t COLLECTOR ETLiBE COVER BODY HYDROSTATIC RELIEF VALVE For installations utilizing a hydrostatic relief valve SP 1056), using a collector tube (SPI 055) will maintain a clear path to the hydrostatic valve. At least one hydrostatic relief valve in a set of suction outlets will allow hydrostatic uplift pressure caused by ground water to be relieved into the pool or spa. WHAYWARDPocl Products _ Page -5° of 8 DUAL SUCTION OUTLET SET ' " * ISDUALSWG REV D . SPARE PARTS LISTS moi WG I 048AVPAK2/ WG1049AVPAK2 1 WG 105 1 AVPAK2/ WG I 052AVPAK2/ WG I 053AVPAK2/ WGI054AVPAK2 WHAYWARDpooi Products ITEM SPARE PART DESCRIPTION QTY 1 WGX1030Z2A SCREW SET 1.0 2 WGX1048E COVER, SUCTION OUTLET 1.0 2 WG1048EW COVER, SUCTION OUTLET 1.0 3 WGX1048B RING, SUCTION OUTLET 1.0 4 SPX1048D GASKET 2.0 5 SPX1051ZI 1 1/2 IN PLASTIC PIPE PLUG 1.0 6 SPX1053Z1 2 IN PLASTIC PIPE PLUG 1.0 SPX1039Z187 SCREW SET 1.0 OTES: IG1048AVPAK2 / WG1049AVPAK2 ] %" NPT Bottom Plug WG1049AVPAK2 2" NPT Side P]ug SPARE SCREW SET INCLUDES SCREWS FOR SUMPS WITHOUT METAL INSERTS. IF SUMP HAS METAL INSERTS INSTALLED ADD (1VI) TO END OF PART NUMBER. SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF SUMPS, WITH OR WITHOUT METAL INSERTS. ITEM SPARE PART DESCRIPTION QTY 1 WGX1030ZlA SCREW SET 1.0 COVER, SUCTION 2 WGX1048E OUTLET 1.0 COVER, SUCTION 2 WG1048EW OUTLET 1.0 1 1/2 IN PLASTIC 3 SPXl05lZl PIPE PLUG 1.0 2 IN PLASTIC PIPE 4 SPX1053Z1 PLUG 1.0 NOTES: WG1051AVPAK2 / WG) 052AVPAK2 1 %" NPT Bottom Plug WG 1053AVPAK2 / WG 1054AVPAK2 2" NPT Bottom Plug SPARE SCREW SET INCLUDES SCREWS FOR SUMPS WITHOUT METAL INSERTS. IF SUIVEP HAS METAL NSERTS INSTALLED ADD (M) TO END OF PART NTUMBER. SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF SUMPS, WITH OR WITHOUT METAL rNTSERTS. Page 6 df - DUAL SUCTION OUTLET SET ISDUALSWG REV D WG1153AVPAK2/ WGI154AVPAK2 T - r WG 1030AVPAK2 ITEM SPARE PART DESCRIPTION I QTY 1 WGX1030Z1A SCREW SET F1.0 2 WGX1048E COVER, SUCTION 1.0 2 WGX1048E OUTLET 1.0 3 WGX1058C COVER, SUCTION 1.0 2 WG1048EW OUTLET 1.0 EXTENSION 3 WGX1153B COLLAR 1.0 1 1/2 IN PLASTIC 4 SPX1051ZI PIPE PLUG 1.0 2 IN PLASTIC PIPE 5 SPX1053Z1 PLUG 1.0 NOTE: SP1153AVPAK2 / SP1154AVPAK2 2" NPT Bottom Plug SPARE SCREW SET INCLUDES SCREWS FOR SUMPS WITHOUT METAL INSERTS. IF SUMP HAS METAL INSERTS INSTALLED ADD (M) TO END OF PART NUMBER. SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF SUMPS, WITH OR WITHOUT METAL INSERTS. ITEM SPARE PART DESCRIPTION QTY 1 WGX1030Z1A SCREW SET (8" ROUND) 1.0 2 WGX1048E COVER, SUCTION OUTLET 1.0 2 WG1048EW COVER, SUCTION OUTLET 1.0 3 WGX1058C ROUND FRAME 1.0 SPARE SCREW SET INCLUDES SCREWS FOR SUMPS WITHOUT METAL INSERTS. IF SUMP HAS METAL INSERTS INSTALLED ADD (M) TO END OF PART NUMBER. SPARE COVER INCLUDES SCREWS FOR FRAME, WITH OR WITHOUT METAL INSERTS. SEE NOTICE. ON PAGE 3 FOR FIELD FABRICATED OUTLETS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. AMARD Pool Products r., :oci con, Pale 7 -of 8, DUAL SUCTION'OUTLET SET ISDUALSWG REV D HAYWARDO MUTED WARRANTY This equipment was inspected before shipment from our plant. To original purchasers of this equipment, Hayward Pool Products, 620 Division Street, Elizabeth, New Jersey, warrants its products free from defects in materials and workmanship for a period of ONE (1) year from the date of purchase. Parts which fail or become defective during the warranty period, except as a result of freezing, negligence, improper installation, use, or care, shall be repaired or replaced, at our option, without charge, within 90 days of the receipt of defective product, barring unforeseen delays. To obtain warranty replacements or repair, defective components or parts should be returned, transportation paid, to the place of purchase, or to the nearest authorized Hayward service center. For further Hayward dealer or service center information, contact Hayward customer service department. No returns may be made directly to the factory without the express written authorization of Hayward Pool Products To original purchasers of this equipment, Hayward Pool Products warrants its vacuum release systems to be free from defects in materials and workmanship for a period of ONE (1) year from the date of purchase. Vacuum Release Systems which become defective during the warranty period, except as a result of freezing, negligence, improper installation, use or care, shall be repaired or replaced, at our option, without charge. All other conditions and terms of the standard warranty apply. Hayward shall not be responsible for cartage; removal and/or reinstallation labor or any other such costs incurred in obtaining warranty replacements. The Hayward Pool Products warranty does not apply to components manufactured by others. For such products, the warranty established by the respective manufacturer will apply. Some states do not allow a limitation on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. HAMA] LDF Pool Produ&5 t With HP7 Microprocessor Programming Included PERMIT # and - TM S: 135 & 155 1,156 TLY OL els: h TM fool &Spa Heat Pump Owner's Manual and Installation Guide CA 7nora CaI SWIMMING POOL MUT PVMPS Attention Installer: This manual is purchaser's property; leave with heat pump owner! PN: LTPOO14 311 R/0R vw' NOTES r rr r rr rr 9-1 AM S 1-800-786-7751 y.. TABLE OF CONTENTS WELCOME TO THE TEAM ----------------------------------------------5 IMPORTANT FEATURES OF YOUR NEW HEAT PUMP ------------------6 HOW A HEAT PUMP WORKS ------------------------------------------7 SAFETY INFORMATION ------------------------------------------------ 8 QUICK START & STOP -------------------------------------------------10 HEATER CONTROLS ---------------------------------------------------12 Control Panel Layout -----------------------------------------------12 Buttons, Lights, and Display --------------------------------------12 Operational & Programming Codes --------------------------------13 Owner -Level Programming (complete) ---------------------------14 MAINTENANCE AND GENERAL OPERATION --------------------------18 General Maintenance -----------------------------------------------18 Safety During Cleaning Operations -------------------------------18 Maintaining Proper Water Flow ------------------------------------19 Controlling Water Chemistry --------------------------------------19 Controlling Irrigation and Storm Water Run Off ------------------20 Maintaining Clearances Around Heater ---------------------------20 Continued on Next Page) GENERAL NOTES, PERMIT # 1. -For pool • plan, size, deck, and special details, see Contractors Pool Plan. 2. Pool Walls shall be 5' thick and Floors shall be 6' thick and shall be pneumatically applied Concrete with a Compressive Strength of 3,000 psi in 28 days. Concrete Decks shall be 2,500 psi. Concrete construction will conform to ACI Standard 318. 3. All Pool construction shall comply with Florida Building Code Building 2007 and Florida Building Code Residential 2007, together with 2009 Revisions, ANSI/NSP National Standard -5 for Residential Inground Swimming Pools, ANSI/NSP National Standard -3 for Permanently Installed Residential Spas, ANSI/APSP-7 American National Standard for Suction Entrapment Avoidance In Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins and the Latest Adapted National Electric Code (NEC). 4. All Pool Piping to be Schedule 40 PVC, bearing the mark of NSF Approval unless otherwise noted. 5. All Reinforcing Steel to conform to ASTM 615, Grade 40. Reinforcing shall be #3 bars at 12' on center in each direction, w/ 15' lap joints in walls and floors up to 6'. Over 6' use 13 bars at 6' on center in each direction in the areas over 6'. If Concrete is cast against Bare Earth without a Separation Barrier, the minimum cover shall be 3'. With a Barrier (Steeltex) between Concrete and Earth, the minimum cover shall be %*. 6. All Metallic Pool Fittings within 5' of the inside wall and deck reinforcing steel to be bonded to the Pool Reinforcing Steel with #8 AWG Copper Wire. The J8 Copper Wire to be run internally and externally with the NEC approved PVC Light Conduit form the Light Niche to the Junction Box. Completion of the pool grounding to the Electrical Panel Ground to be by Electrician. 7. Boq all Sheathed Cables, Raceways, Metal Piping and all Fixed Metal Parts not separated by a permanent barrier, 9 within 5'-0' Horizontally from Water and 12'-0' Vertically of Maximum Water Level. 8. Equipatential Bonding to be accomplished in accordance with Article 680 of the Latest Adapted National Electrical Code (NEC). 9. Pool or Patio shall bear only on Rock or Clean Sand, which shall be compacted to provide a Structurally Safe Bearing Capacity. Any Unsuitable Material encountered in excavation shall be removed in its entirety and the area shall be backrilled with acceptable material and properly compacted. Where unsuitable Material cannot be removed, the pool must be redesigned. 10. The Contractor must protect Existing Structures from failure by acceptable methods if required. The Engineer accepts no responsibility for the safety of Existing Structures. 11. The Design Engineer assumes no responsibility for pool construction in Easements or Required Setback areas. Pool Contractor and/or Owner shall verify the layout and all dimesions shown prior to construction. 12. Contractor shall determine the location of all Utilities in relation to the Pool and its Equipment and ensure minimum clearances in accordance with ,Local Regulations and Ordinances. 13. Contractor shall provide adequate Temporary Fencing around the construction area to prevent unauthorized entry into the Pool Area. 14. If a water supply is, provided, a minimum 3' Atmospheric Break will be provided. io 15. Al Structural, Filtration and Electrical details outlined in these drawings also relate '• AIOU Ao LENGTH 5 THERAPYO.C. EACH WAY LADDERS ARE TO BE 4. 6' WALL - WATER COPING WA R y;%: CROSS BRACED PER ESCUTCHEON011cr6* LINE TILES UNE MANUFACTURERS SPECS a PLATE POOL LINE n DRAIN COVER/GRATE , :r 14' MIN. S.S. LADDER POOL DECK4=•,: = STEPS r : • 5' MUST CONFORM TO N 18 MAX. S WLRN-,^ z POOL THE LATEST EDITION ry EXPANSION m W LIGHT OF ANSI/ASME W 112.19.8 i,«.': SLIP RESISTANT JOINTS AS WEDGE REQUIRED POOL STEPS: 1, TREAD SURFACE ANCHOR RISERS: 12' MAX. DUAL SUCTION OUTLET AND APPROVED GRATE ADDITIONAL CONCRETE TREAD: 10' MIN. (240 SQ. IN. MIN.) WITH 3'-0' OF SEPARATION CENTER UNE TO UNDISTURBED AS REQUIRED FOR CENTER UNE OR APPROVED CHANNEL DRAIN SOILS y 3' MIN. TO 6' MAX STURDY INSTALLATION STEEL GRID AT THEPOOLSECTIONSETPOOLI NO VOIDS) BETWEEN TREAD IXDEEPESTPOINT LONGITUDINAL) SWIM—OUT DETAIL POOL WALL RUBBERAND-- BUMPER CONDCTOR TO SHELL CONCRETE DECK (OPTIONAL) W/ SUP RESISTANT REINFORCING TOPPING ON COMPACTED GROUND W/ ALL DECK OVER TYPICAL LADDER DETAILORGANICMATERIALREMOVED. 4' NOM. THK. W/ 8• POUR OR FIBER MESH OR 5' NOM. THK. W/ #3 REBARS. BRICK COPING AWG COPPER WIRE 1—#3 BAR CONT. IN 5' THK WALL 0' 4' JUNCTION BOX 8 USE 2—#3 BARS CONT. IN 8'x8' BY OTHERS) WATER TIME BOND BEAMS) D SNE TO SERVICE CLOCK O TO TRANSFORMER 6" OF 1—j3 BAR PANEL WATER LINE BY OTHERS) 2-13 BARS WATER CONT. IN 5' SPST TOGGLE o z CONT. IN TILES BELINEIACMK BOND 4'-0. SWITCH DISC. S, 8'X8' BO NMD 5' 5' POOL BOXJUNCTIONLr&—LE NS. U.L."APPROVED 120 VAC/300W POOL DECK i MARBLE PLASTER LIGHT W/ GFl OR 12V/400W MAX. POOL MIN. U4' COVER WATER LECTRK/IL WORK LIGHT W/ LOW WATER CUT—OFF IN U.L. OVER ALL BARS 1 LINE CONFORM WITH APPROVED GREY PLASTIC FORMING SHELL SEE NOTE 15) ART. 680 OF THE OR APPROVED EQUAL W/ #8 AWG BOND 3 #12 IN }¢' LATEST ADAPTED NEC. KWATERWIREPERN.E.C. ALTERNATE BEAM coNouT STEELTEX (OPTIONAL) 3 BARS 0 12' O.C. EACH WAY FINISH DETAIL MAF. POOL LIGHT LOW CU/4oCUT—OFF OR 120 VAC.. W/ GFl POOL STRUCTURAL DETAILS PER NEC. DISTANCE LESS NEW OR VARIES 18' THAN 1 ON 1 + 1 EXISTING ELECTRICAL DIAGRAM SEE SEAT coPlNc STRUCTURE y WATER PLAN WATER I itiG F11,ZW, LINE to prevent unauthorized entry into the Pool Area. 14. If a water supply is, provided, a minimum 3' Atmospheric Break will be provided. io 15. Al Structural, Filtration and Electrical details outlined in these drawings also relate '• to Spa Construction. BARS ®J "\_( 2) REBOUND 16. All Pool and Spa Heaters shall be equipped with an On/Off Switch mounted for ' O,C.E,W, (2) 8'0 ANTI—VORTEX PLASTER FINISH easy access to allow the Heater to be Shut Off without adjusting the Thermostat DRAINS SEPARATED BY 3' settings and to allow restarting without relighting the Pilot Light. 17. WARNING! To empty the Pool for any reason, the Hydrostatic Uplift Pressure must SPA STRUCTURAL DETAILS TYPICAL WALL AND be eliminated. The Owner must consult a Contractor experienced in eliminating Uplift Pressure. FLOOR W1 THIN 1 MAIN DRAIN UNE SPILLWAY PER 6x6 GLASS—BLOCK ANGLE OF REPOSE 2 SKIMMER UNE CONTRACTORS POOL MOUNTED IN 2,500 psi V- 4 3 WASTE UNE COPING PLAN CEMENT (IF SPECIFIED) D 4 RETURN LINE C 3 5 PRESSURE CLEANING WATERLINE TILES UNE (OPTIONAL) WATER UNE A HAIR & LINT STRAINER 5 B B RECIRCULATION PUMP INTERIOR C FILTER A D IN—UNE CHLORINATOR P001 FINISH OPTIONAL) 21 E HEATER (OPTIONAL) 0 C E. EBAR ® 12 W. FILTER SYSTEM RAISED SPA DETAIL CONTRACTOR MUST PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6' ON CENTER IN BOTH DIRECTIONS IN THIS CRITICAL AREA. ALSO THE POOL SHELL WALL SHALL BE CONSTRUCTED TO 6' THICKNE THE STEEL MAT AND THICKER SHELL'WALL SHALL EXTEND ALONG THE CRITICAL AREA AND TO A POINT WHICH IS GREATER THAN THE MINIMUM REQUIRED AS DETERMINED BY THE 1 ON 1 + 1 METHOD. PLAN EXPIRES 1 YEAR FROM THE SIGNATURE DATE OR THE EFFECTIVE DATE OF A MAJOR FLORIDA BUILDING CODE CHANGE WHICHEVER IS SOONER MAY 04 2011 GIRD H. SHEP DS N, P.E. FL PE # 1 333 672° N. Semoron Blvd., Ste' 204 Orlando, ,FL 32807 Office: (407) 275-1099 Fax: (407):275-1015 Drawn By: A R PATTON do Specializing in Associates, Inc. Residential and Commercial 407) 977-1892 Pools, Fountains and Features 5497 BENCHMARK LANE SUITE 101 m,a,„tull, sumw SANFORD, FL 32773 407) 330-5049 Champagne Pools & Spas CPC 032557 j Swimming Pool Specification For: ERVIN RODRIGUEZ 289 McKAY BLVD. SANFORD FL 32771 VOID IF h L i EP ED Scale: None Rev 7 — 11/18/09 J3 BARS ® 12' I 5 THERAPYO.C. EACH WAY 4. 6' WALL - RETURN THICKNESS LINES uAooif to Spa Construction. BARS ®J "\_( 2) REBOUND 16. All Pool and Spa Heaters shall be equipped with an On/Off Switch mounted for ' O,C.E,W, (2) 8'0 ANTI—VORTEX PLASTER FINISH easy access to allow the Heater to be Shut Off without adjusting the Thermostat DRAINS SEPARATED BY 3' settings and to allow restarting without relighting the Pilot Light. 17. WARNING! To empty the Pool for any reason, the Hydrostatic Uplift Pressure must SPA STRUCTURAL DETAILS TYPICAL WALL AND be eliminated. The Owner must consult a Contractor experienced in eliminating Uplift Pressure. FLOOR W1 THIN 1 MAIN DRAIN UNE SPILLWAY PER 6x6 GLASS—BLOCK ANGLE OF REPOSE 2 SKIMMER UNE CONTRACTORS POOL MOUNTED IN 2,500 psi V- 4 3 WASTE UNE COPING PLAN CEMENT (IF SPECIFIED) D 4 RETURN LINE C 3 5 PRESSURE CLEANING WATERLINE TILES UNE (OPTIONAL) WATER UNE A HAIR & LINT STRAINER 5 B B RECIRCULATION PUMP INTERIOR C FILTER A D IN—UNE CHLORINATOR P001 FINISH OPTIONAL) 21 E HEATER (OPTIONAL) 0 C E. EBAR ® 12 W. FILTER SYSTEM RAISED SPA DETAIL CONTRACTOR MUST PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6' ON CENTER IN BOTH DIRECTIONS IN THIS CRITICAL AREA. ALSO THE POOL SHELL WALL SHALL BE CONSTRUCTED TO 6' THICKNE THE STEEL MAT AND THICKER SHELL'WALL SHALL EXTEND ALONG THE CRITICAL AREA AND TO A POINT WHICH IS GREATER THAN THE MINIMUM REQUIRED AS DETERMINED BY THE 1 ON 1 + 1 METHOD. PLAN EXPIRES 1 YEAR FROM THE SIGNATURE DATE OR THE EFFECTIVE DATE OF A MAJOR FLORIDA BUILDING CODE CHANGE WHICHEVER IS SOONER MAY 04 2011 GIRD H. SHEP DS N, P.E. FL PE # 1 333 672° N. Semoron Blvd., Ste' 204 Orlando, ,FL 32807 Office: (407) 275-1099 Fax: (407):275-1015 Drawn By: A R PATTON do Specializing in Associates, Inc. Residential and Commercial 407) 977-1892 Pools, Fountains and Features 5497 BENCHMARK LANE SUITE 101 m,a,„tull, sumw SANFORD, FL 32773 407) 330-5049 Champagne Pools & Spas CPC 032557 j Swimming Pool Specification For: ERVIN RODRIGUEZ 289 McKAY BLVD. SANFORD FL 32771 VOID IF h L i EP ED Scale: None Rev 7 — 11/18/09 D TURNDOWN 'NOTES COMPACTED CONCRETE 1. Detail is based on NO surcharge behind the Turndown and the Ground away from SUBGRADE POOL DECK the Turndown is Level (>4 to 1). Turndown may abut Ribbon Footer and be tied into Footer if Appropriate, with #3 Rebar. 2. Turndown shall bear on Rock, Clean Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling 1—#5 BAR CONTINOUSorShifting. 3. All Reinforcing Steel is to Conform to ASTM 615, Grade 40. g• 4. Concrete shall contain Fiber Mesh and have a 28 Day Compressive Strength of 4'0 CONCRETE PILASTER I 2,500 PSI AT 5'-0* ON CENTER WITH 1—#3 BAR VERTICALLY 5. All Construction to Conform to Florida Building Code Building 2007, Florida Building rr—TI'—= Code Residential 2007, together with 2009 Revisions. , 6. Refer to Contractors Plan on file with the Building Department for Details on Turndown Location. 7. If the Base of the Turndown does not extend into the Old (Existing) Ground, a 4'0 Pilaster will be required every 5'-0' that will be either 2'-0' into the Ground or to 6" into the Indigenous Material, Whichever is Deeper. The Pilaster will have a 3 Rebar tied into the 15 Rebar in the base of the Vertical Pour. B. A Deck Turndown is NOT intended to be a substitute for a Retaining Wall. If the Vertical Dimension from the Top of the Concrete Deck to the Old (Existing) Ground ruches 42' for a 12' Turndown, 48' for a 18' Turndown or 54' for a 24' Turndown, for more than 207. of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a Turndown should not be used. 9. For a Paver Deck, if the Vertical Dimension from the Top of the Deck to the Old Existing) Ground reaches 30.0' for a 12' Turndown, 36.0' for a 18' Turndown or - 42.0* for a 24' Turndown, for more than 20% of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a Turndown should not be used. 10. If a Screen Enclosure is to be installed on top of the Turndown, the Swimming Pool Contractor must Coordinate attachment of the Screen Enclosure to the Turndown with the Screen Contractor. FOOTER NOTES 1. If a Screen Enclosure is to be installed, the Swimming Pool Contractor must Coordinate Construction of any required Footer with the Screen Contractor. 2. Footer shall bear on Rock, Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling or Shifting. 3. ' Concrete shall have a 28 Day Compressive Strength of 2,500 PSI with Fiber Mesh or 6x6 -10x10 W.W. Mesh. 4. (3) #3 Rebars is Equivalent to (1) #5 Rebar. 5. A Footer may be installed with a Brick Paver Pool Deck if required by the Jurisdiction or at the Option of the Contractor and may be placed over the Top of the Footer or Abutting the Side of the Footer. 1-13 BAR CONTINOUS 1—#5 BAR VERTICALLY AT 36. ON CENTER N FPROPOSED FINISHED o GRADE (COMPACTED) 1 I C' EXISTING FORADE R- 4" CONCRETE DECK TURNDOWN PROPOSED CONCRETE FINISHED POOL DECK GRADE , NO FOOTER 1 . BRICK E• BASE MATERIAL POOL f COMPACTED e 1—#5 BAR CONTnINOUS 3 BAR CONTINOUS 1—#5 BAR VERTICALLY AT 36" ON CENTER A = 12' TO 24' a B=X4XA(9'T018 PROPOSED FINISHED GRADE (COMPACTED) m 4 MIN. 1 4"0 CONCRETE PILASTER - AT 5'-0' ON CENTER WITH I 0STIt 1-3 BAR VERTICALLY - -C' JG;RADE fli, `o 4' PAVER DECK TURNDOWN PROPOSED CONCRETE FINISHED POOL DECK GRADE . 8' I 1—#5 BAR CONTINOUS PROPOSED CONCRETE FINISHED POOL DECK GRADE . 12" 2—J5 BARS CONTINOUS 8" x 12" FOOTER 8" x 8" FOOTER PROPOSED CONCRETE FINISHED POOL DECK GRADE i .. N1= H- 2—#52—#5 BARS CONTINOUS 12' 12" x 12" FOOTER BRICK PAVER POOL DECK SEE PAVER DECK TURNDOWN DETAIL FOR INFORMATION NOT SHOWN PAVER SECURED TO TOP OF TURNDOWN BY PAVER INDUSTRY STANDARDS ALTERNATE PA VER • ON TURNDOWN AT 36' ON CENTER 1—#5 BAR CONTINOUS BRICK PAVER POOL F`—COMPACTED PAVER BASE MATERIAL g• COMPACTED SUBGRADE ALTERNATE PAVER LOCATION Drawn By: A R PATTON & Specializing in Associates, Inc. Residential and Commercial 407) 977-1892 Pools, Fountains and Features 5497 BENCHMARK LANE SUITE 101 A aqueu SANFORD, FL 32773 Champagne ( 407) 330-5049 Pools & Spas CPC 032557 MAY 04 2n11 Swimming Pool Specification For: Data ORDO •H. SHEP RDS N, P. E. FL PE J 19333 672 N. Semoran Blvd., Ste 204 Orlando, FL 32807 Office: (407) 275-1099 Fax: (407) 275-1015 Scale: None ERVIN RODRIGUEZ 289 McKAY BLVD, SANFORD FL 32771 D IF AL EF< ED Rev 4 — 4/15/09 i r ANSI/APSP-7 2006 Specifies three methods for determining the maximum system flow rate. The following simplified TDH calculation Is one of the - methods specified. Simplified Total Dynamic Head (TDH) Calculation Worksheet Minimum Flow Rate Required: 31.5 gpm Per Skimmer (Required: 1 skimmer per 800 sf of surf. area) 1. Calculate Pool Volume: 30 x x 7.48(g al./ cubic foot) = Surf. Area) (Avg. Depth) /"(Vol ) 2. Determine preferred Turnover Time in hours: b x 60 (min. / hr.) = Hours) (Turnover3. Determine Ma F w Rote:7- / _;0 + _ of ' gal. (Turnover Mine.) (P Fl e) (Feature Flow Rate) (System Flow Rate) 4. Spa Jets: x gpm per jet = flow rate. Al( No. of Jets) (Jet Flow) (Total' Jet Flow Rate) For single pump pool/spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool & spa) Determine Pipe Sizes: Branch Piping to be inch to keep velocity ® 6 fps max. at • gpm Maximum System Flow Rate. Trunk, Skimmer & inch to keep velocity ® 8 fps max. at gpm Maximum System Flow -Rate. Suction Piping to be Return Piping to be inch to keep velocity ® 10 fps max. at 03 gpm Maximum System Flow Rate. Determine Simplified TDH: 1. Distance from pool to pump in feet: 2. Friction loss (in suction,pipe) in _inch pipe per 1 ft. 0gpm =416 (from pipe flow/friction loss chart) 3. Friction loss (in return pipe) in inch pipe per 1 ft. ®gpm =1 (from pipe flow/friction loss chart) 4. x Length A SgSt. Pipe) (Ft of hea / ft of Pipe) (TDH P' e) 5. x __ Length of Return Pipe) (Ft of head/1 ft of Pipe) PH Relum Pipe) TDH in Piping: Filter loss in TDH (from filter data sheet): Heater loss in TDH (from heater data sheet): Total all other loss: Selected Pump and Main Drain Cover. Total Dynamic Head ODH): Pump selection 1 3/ yJus ng pump curve for TDH & System Flow Rate Make and Model) Main Drain Cover (System Flow Rate must not exceed approved cover flow rates) Make and Model) Notes: Minimum system flow based on min. flow per skimmer of 35 gpm. Determine the Number and X= of Required In -Floor Suction Outlets: Check all that apply. TDH Calculation Ontiopg For each pump r --Check one. Simplified Total Dynamic Head (SAH) Complete STDH Worksheet - Fill in all blanks. Total Dynamic Head (TDH) Complete Program or other calcs. Fill in required blanks on worksheet & attach calculations. Maximum Flow Capacity of the new or replacement pump. 1. If a variable speed pump is used, use the max. pump flow in calculations. 2. For side wall drains, use appropriate side wall drain flow as published by manufacturer. 3. Insert manufacturer's name and aproved maximum flow 4. See installation instructions for number of ports to be used. 5. In -Floor suction outlet cover/grate must conform to most recent edition of ASME/ANSI A112.19.8 and be embossed with that edition approval. 6. Pump, Filter & Heater make and model cannot changed, and equipment location cannot be moved closer to pool without submitting a revised plan and TDH calculation worksheet for approval. Flow and Friction Loss Schedule 40 PVC Pipe V Per Foot Feet Per Second Feet Conversion Chart P' Sae 6 0 8 1 16 10 a 1' 18 gpfn 0.14' 21 gpm 0.23' 26 gpm 0.35' 1.5' 37 gpm 0.08' 50 gyrn 0.14' 62 gpm 0.21' 2' 62 gpm 0.06' 82 gprn 0.10' 103 gpm 0.16' 2.5' 88 gpm 0.05' 117 gpm 0.09' 148 gpm 0.13' 3' 136 Wn 0.04' 181 Wn 0.07' 227 gpm 0.10' r234 0.03' 313 0.05'392 15.9 0.07' s• 534gprn I 0.02' 712 wrn 1 0.03' 3 6.9 S-0- Q 2 suction outlets ® a2. S gpm max. flow (see note 2). 16 Q Q Q Q 3 suction outlets ®gpm max. flow (see note 3). channel drain ®gpm w/ports (see note 4). Total Head In Feet Conversion Chart 0 Inches Mercury (Vacuum Gauge) 1 2 4 1 6 8 1 10 1 12 14 1 16 1 18 0 0.0 1 2.3 4.5 6.8 9.0 11.3 1 13.6 15.8 1&1 20.3 ' 1 2.3 1 4.6 6.8 9.1 11.4 13.6 15.9 18.1 20.4 22.7 2 4.6 6.9 9.1 11.4 13.7 15.9 18.2 20.4 22.7 25.0 3 6.9 9.2 11.5 13.7 18.0 18.2 20.5 22.8 25.0 27.3 4 9.2 11.5 13.8 16.0 18.3 20.5 22.8 25.1 27.3 29.6 5 11.5 13.8 16.1 18.3 20.6 ' 22.8 25.1 27.4 29.6 31.9 6 13.9 16.1 18.4 20.6 22.9 25.2 27.4 29.7 31.9 34.2 7 16.2 18.4 20.7 23.0 25.2 27.5 29.7 32.0 34.3 38.5 8 18.5 20.7 23.0 25.3 27.5 29.8 32.0 34.3 36.6 38.8 9 20.8 23.1 25.3 27.6 29.8 32.1 34.3 36.6 38.9 41.1 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7 38.9 41.2 43.4 11 25.4 27.7 29.9 32.2 34.5 38.7 39.0 41.2 43.5 45.8 01 12 27.7 1 30.0 32.2 34.5 36.8 39.0 1 41.3 43.5 45.8 48.1 C 13 30.0 32.3 34.6 36.8 39.1 41.3 43.6 45.9 48.1 50.4 14 32.3 34.6 36S 39.1 41.4 43.8 45.9 48.2 50.4 52.7 49 15 34.6 38.9 39.2 41.4 43.7 45.9 48.2 50.5 52.7 55.0 16 37.0 39.2 41.5 43.7 48.0 48.3 50.5 52.8 55.0 57.3 17 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 18 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 19 43.9 46.2 48.4 50.7 52.9 55.2 57.4 59.7 62.0 64.2 v 20 46.2 48.5 50.7 53.0 55.2 57.5 59.8 62.0 64.3 66.5 a 21 48.5 50.8 53.0 55.3 57.6 59.8 62.1 64.3 66.6 68.9 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 24 55.4 57.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 25 57.8 60.0 62.3 64Z 66.8 69.1 1 71.3 73.6 75.8 78.1 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 27 62.4 64.6 66.9 69.2 71.4 73.7 75.9 78.2 80.5 82.7 28 64.7 66.9 69.2 1 71.5 73.7 78.0 78.2 80.5 82.8 85.0 29 67.0 69.3 71.5 73.8 76.0 78.3 80.5 82.8 65.1 87Z 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 89.6 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92 0 32 73.9 76.2 78.4 80.7 83.0 85.2 87.5 89.7 910 94Z 33 76.2 78.5 80.7 83.0 85.3 87.5 89.8 92.0 942 98.6 34 78.5 80.8 83.1 85.3 87.6 89.8 92.1 94.4 96.8 98.9 35 80.9 83.1 85.4 1 87.6 89.9 92.2 1 94.4 98.7 98.9 101.2 NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. This form is the property of Gordon H. Shepardson, PE and may only be used in conjunction with my Residential Swimming Pool Specification Drawings or by others with my written permission. we Contractors 5ignature Contractors Printed Name Contractors Cert No. Contractors one a. MAY U 4 2011 ' Date This worksheet was Created and provided By GORDON H. SHEPARDSON, P.E. FL PE # 19333 . 672 N. Semoran Blvd., Ste 204 Orlando, FL 32807 Office: (407) 275-1099 Fax: (407) 275-1015 Drawn By: A R PATTON & Specializing in Associates, Inc. Residential and Commercial 407) 977-1892 Pools, Fountains and Features AnagwtmcWBulider Champagne Pools & Spa: 5497 BENCHMARK LANE SUITE 101 SANFORD, FL 32773 407) 330-5049 CPC 032557 Swimming Pool Specification For: ERVIN RODRIGUEZ 289 McKAY BLVD, SANFORD FL 32771 JAD fFALiEFED Scale: None Rev 7 - 11/18/09 MAY-17-2011(TUE) 13;36 CHAMPAGNE POOLS r Permit Number_ Folio/Parcel Identification Number) Prepared by_ 1 / Return to-, NOTICE OF COMMENCEMENT FAX)407 323 6941 P.002/004 Ilit 11111Arilif 111lllmlaha11mutlit111110lilitli11l MARYMe MORSE, CLERK W CIRCUIT COURT SPINDLE COLN" DR 075M 6ZR" 049 t. 1 32 RECORDED 05109/2011 00:10:37 Alli RECI.IRDING FEES 18.00 RMIRDI_D BY 1 Eckenrath(all) State of Florida. County of Seminole 31 • I q -:5 I - 5-a#7 - 00 0 0 - O 5% 0 The undersigned hereby gives notice that improvement(s) will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commeficement. 1. Dps ri Ion of property (legal HFIScj ttioh of the •t: -- rty, and street address If available) 2. Gepvral descAption Af r_pp mont(s) n — 3. Owner inform Goy• Name 161:1 ... c.1E..d: v Telephone Number Address,M/j, r Interest in Property f2 4. Fee Simple Title Holder if dlher lha w er shown above) Name I JA7elcphonc Number Address S. Contractor Narne CHAMPAGNE POOLS Or CENTRAL FLORIDA Telephone Number -407-330-5Q49 v Address 5497 BENCHMARK LN.. SUI -TF, 101 SANFO" M 3777• B. Surety (if any) _ Name Telephone Number Address _ Amount of bond $ 7. Lender (if any) Name 11. Telephone Number N Arirlrp CS fl. Persons v"vithin the State of Florida designated by Owner upon whom notices or other documents may be staved as provided by §713.13(1)(a)7, Florida Statutes. Name , / t!i _ Telephone Number !la Address 9- In addition to himself or harself, Owner designates the following to receive a copy of the Lienor's Notice as provided In §713.13(1)(b), Florida Statutes. Telephone Number /> I_ ;q Adi 10. Expiration datE of notice of commencement (the expiration date Is one year from the date of recording unless a different date Is specified) WARNING I'D OWNER: ANY IAYMENTSn1.1DL• BY T)1);QNNCRA17170 FIEMMIMATIONOriitCNDTICEOrCQb1h1CNCEh1ENTARE CONSIDERED Ip7ritOpElt PAYMENTS UNDER CilAtnTit713.PARTI.SECT1gN?11-13, FLOtt1DAST' TUMS.AND CAN RiSULTIN YOUR PAYING l 1'ICf: IrOII IM111'RO\1QptCtY1 7Q 1'oUlt 1'ftQPERTI: A NOTICE 017 CommeNCEfliE• NT 6lusrBE RECORDED AND POSTED oN'I•IIEJOII SrrE QEFORETIM rMSr INSPCCnDN. 1FY0U 1NTENDTO OBTAiN [riNANC1Nc.CONSUL'rwrrn TRUR LEND OR AN A't rOnNCY Pl:rD1tL• COhtn[ CINC %VDRIC NC - SIR NOTICCOrCOAINIENCENIENT. 5lonatura of Ownur Signatory's PrIatod Namamtlelo cp or Owner:; Authorized OiricarlDlrectorlPannarlManager g713.13[7][d]) The foregoing instrument was acknowledged before me this 1. ay of n _ e5r) (name of person `Z of :+ 011 offirrr„IprC}eep}larpa/ fn fpet) (Name of party an behalf ofwhom Instrument wan executed) of Xl0V X— (Prlrl4 type, or stamp commissioned name of Nolery Public) te sonally K own LdR Produced !D a I d Nulary?ubtic3la>eolFlorld2TypeofIDPdicedCnristapnerMVAnggelo1•- t, Verltlaadon purunnt to ScrVan 97 -OW. Florida Siatutcs: Under penaltlus of pmr)ury, I dociarn that has a 'the re trYdrtf[U T8C ta tl In tt aro trim to the best of my knowladga and/ballof. E MORSE CLERK OF CIRCUIT COURT Slynuturo of Natural Per•olt G19619 on Lino 11-Abava $EMINOLE COUNTY. FLORIDA Form Revised: 111211107 pL ollOeo, r ry f" i FRK MAY-17-2011(TUE) 13:37 CHAMPAGNE POOLS Charnpaalw Pools of Central plortda, Inc 5497 Benchmark lane, Suite 9101 Sanford, Florida 32773 407) 330-5049 - office 407) 323-6041 - fax www.champagnapoolandspa.com FAX)407 323 6941 P.003/004 An alt:atech Builder License Numbers CPC 032557 CPC 057135 NAME: L=t^%1A- (Herein ^ (Herein termed 'Owner') JOB ADDRESS: _G L ` 131. CITY hw&g STATE 7/ - ZIP '>W r MAILING ADDRESS- CITY STATE ZIP TELEPHONE: (Home) / (Offlca) (Call) 40 LEGAL: Subdivision (Z /T1L(.. Lot# POOL SHAPE: e .;'mv.... POOL SIZE: length - -1 width II Are& sq ft _,&LO' Water depth to la THE; GCNERAL TERMS. CONDITIONS AND WARRANTIES t 1. PLANS: Champagne Pool.:: to Supply pool blueprint and engineering plans. _ _ Inc- nc_ 2, 2,pi]ILDING PERMIT: CP to .iCt as Owners agent to obtain building permit only Irtc. 3. SITE PREPARATION: a. Access fence removed by Owner CP b. ACCC33 fence repiacod by Owner Cr Not Applicable c. Trees in access and pool site areas to be cut down so that stumps will not exceed 3' in height . . . . . . . . . . . . . By Owner d. CP to uproot 3' high x 19" dia. min. stumps at time of excavation in access and area only. p'o.ol 4 of Stumps f yes Q No 1 e. Stumps hauled away. You Q No f. Concrete cut and hauled. . . Yue; Q NO g. Sprinkler cut off by . . Owner IT CP Q h. Sprinkler re-routed . . . . . . By Owner 4. EXCAVA':ION: C1' to excavate pool and remove dirt oil day of excavation only. Inc. a. Additional gill dirt if xsquired is not included in eontxaet , . Tay Owner b. CP I;o include sufficient grading for propara tion or nite. Inc - CP IS NOT RNSF0N$IB= r0A ACCESS INTO YARD, RE-ROUTING SPRIMU=S, REDOING LANDSCAPING, RESODDING OR TRANSPI,ANT:rNG Or PLANTS. By owner S. Engineered Steel Reinforcing complies with ASTM # A615 . . . . . . Inc. 6. Electrical Bonding of shell and equipment - - - - - - - - - - - - - - Inc. 7, Pnoumatically :applied concrete ahul) commonly referred to as Gunite or Shotcretc) . . . . . . . . . . . . . . Inc. a. ONNIM TO WA= C= GUNITru SHELL rOR 10 DAYS . . . . . . . . . . By Owner 6. Temporary construction fence . . . . . Inc - 9. Three (3) steps to shallow end Inc - 10. Love, Suat: ! Lt. Inc. 11. Extended Bench: L " V,h4 ) 4 mal 22. Raised beam with standard a A011 13. TILE: CP Standard swimming pool tile a. Onlv one row of the at water line Name: -T6.0 Yes )l No Q b. Special order and/or larger size not bid on this contract. . . . Not Inc. c. Step Inlay3: 9 -11,0 Color Yr%4+-C" -.05-2 No U 14. TNTF.RT,OR r•TNTSbi; CP to hand trown]. a hard, waterproof plaster finish. Type:. (,Z,c-i Color: Inc. a. OWNER IS RESPONSIBLE FOR FILLING POOL WITH WATER AND BRUSHING DOWN M014 TWICE A DRY FOR TWO W=E $ AFTER IT IS FILLED. . . _ . . . .By Owner 15, Safety Lino Cups, Rope and Floats Inc. 16. Public liability, negligent property damage and workmen's compensation insurance during construction Inc. 17, No additional coat to customer for rain damage to pool during construction - - znc- 19. Deluxe cleaning equipment and water test kit . . . . . . . . .. . . . . . . Inc. 19. Start-up w/ "pool Nchool" instruction Ino. IN THE REVERSE SIDE ARE PART OF TMS AGREEMENT. 1. a. sq. ft. Cartridge filter b. ANSI VII enginacrod 402 maximum performance with minimum Olactrical use. 011 a pre, -formed support pad. . . . . . .Inc. 2. Ono (1) 5kimmor,•large capacity and self-adjusting w/double main drains and 3 returns (no reg. returns . . . . . . Inc. 4. Automatic Chlorinator,. . . . . . . . . Inc. 5. Easy set Timo clock. . . . . . . - Inc. THERAPEUTIC, SPA 1. Spa - sq.ft. with Jets, 2. standard White./L 'qht 3. Spillway 4. Heater - LP / NAT size - 5. Ot 1. Electric Hook-up for all equipment llstad on this agreement Inc. N J"ZNG OR CSANGTNQ =SISTING ELECTRICAL PANEL SOA OR RELOCATION OF OVERHEAD WIRES, IF REQ. BY LOCAL CODE. By Owner 3. Add. Electrical Hook-up for lights, Pane, etc . . . . . . . . . . . . . By Owner 4. Natural Gas Plumbing . . . . . . . By -owner 5. Propane Tank leasing, renting, buying, sat -up and burying aro the asponaibLli-ty 0:9 owner . . . . . By owner 1. Water Purification - type Se.Jz =x C 2. Poo], light - typeL J7 3. Automation Controls - AZ La 4. Automatic Cleaner5. Water Water Features 6. 8. HEATING EQUIPMENT 1. Heater - type Ll' / NAT FIP 4IP.r f`<RF 3i e S a .c.a p. .s •v 2. Solar, Panels _set & Forget valvo_ ,til M. DECKING' 1. Acrylic necking k 9,0 color _ ( 2. Coping Typo .:.. NTS. 3. Acrylic Banding - color =A"-- 4- 4;Lrp:: 5. Raised walls _ 6. Turn downs 7. Rotaining walla B. SCREEN 1. Type Dome, Gable 41 Mansard 2. Two (2) Do -s, gu texF. where require 3. Color - Whit Bronze 4. Elite 5. un Buam MAY-17-2011(TUE) 13;37 CHAMPAGNE P001-5 (FAX)d07 323 6941 P.0041004 WARNING DANGER WARNING t'1r+.t lr>. t:r `1. DO -N -0-T DIVE INTO THIS POOL. tia Y' C", c v,L x•c -cis..« c..•{'. 2. DO NOT INSTALL A SLiDE ON THIS POOL. 3. DO NOT INSTALL A DIVING BOARD OR DIVING ROCK ON THIS POOL. Whether financed through other sources or paying cash the owner agrees to pay the total price of this contract, less the deposit at the following intervals and in the percentages stated below. Change orders or'addendums must be accompanled with full payment, A. Deposit ......... upon signing of this contract TOTAL. CONTRACT PRiCE B. 40% ............ day of dig ' r C. 40% ............ day of shooting of the gunite shell DEPOSIT tof4 $ :3©& 00 D. 20% ............ day of dock installation E. $500.00 ......... upon start-up of pool BALANCE 's rF.r-G'' OFFER AND AGREEMENT: This Contract shall be deemed as an offer to Champagne Pools of Central Florida, Inc. and shall be null and void unless accepted by a duly authorized officer of the contractor within ten business days of the, contract date. The salesman has no authority to bind the contractor. All agreements and understandings are contained in this contract and the Owner warrants that there are no agreements or understandings other than are set forth In this document. Acceptance of the terms of this contract by Contractor is to be communicated to the Owner by transmitting a copy of this contract to them showing acceptance by the sellers by the execution of a duly authorized officer of the Contractor or by commencing construction. THE UNDERSIGNED JOINTLY AND SEVERALLY AGREE THAT THE TERMS AND CONDITIONS ON THE REVERSE SIDE ARE PART OF THE AGREEMENT AND THAT THIS WRITING CONTAINS THE ENTIRE AGREEMENT BETWEEN THE OWNER AND CHAMPAGNE POOLS, AND FURTHER ACKNOWLEDGES THAT EACH OF THEM HAS READ AND UNDERSTOOD THiS ENTIRE CONTRACT, A scale drawing of your swimming pool showing Its location, shape, other details and equipment location shall be attached to this contract within 10 business days and Incorporated herein by reference. The drawing shall be signed by any one of the Owners whose name appears as a signatory herein. The Owner understands that embellishments on the drawing such as umbrella tables, lawn chairs and plants are not part of the pool contract. Owner should receive a copy of the drawing. No additional work shall be done without prior written authorization of Owner, and any such authorization shall be on a CHANGE ORDER FORM" or an "ADDENDUM" form showing the agreed terns and shall be approved by Champagne Pools and shall be signed by any one of the Owners whose name appears as a signatory and addendum must be accompanied with payment in full, if applicable. CAUTION: If pool Is not approved for diving (under 8" depth, see front) you should not install or use a diving board or jump board. Do not dive into this pool. If pool is approved for diving, exercise caution by always diving Into center of the deep and with hands out in front of your head and steer up. Do not permit or practice fancy. dives, stunts, or horseplay. ALL POOL USERS SHOULD BE INSTRUCTED IN THESE LIMITATIONS. NEVER DIVE INTO SHALLOW AREA. Owner acknowledges receipt of a duly executed duplicate copy of this agreement at the time of its execution, with all blank spaces filled in to the extent it is applicable to this project. NOTICE TO PURCHASER DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ IT OR IF IT CONTAINS ANY BLANK SPACES You, the Owner, may cancel this transaction at any time prior to midnight of the third business day after the date of this transaction. See attached Notice of Cancellation form for an explanation of this right. DATE: l rL DAY i , 2011 u Salesperson: Ownor,4- — Accepted by Champag Pools of Central FlorloK Inc. Authorized agent, Owner. THIS CONTRACT IS NOT AN ESTIMATE NOTICE OF_CANCELLATJOLd MATE. You may cancel thls tmnsactlon, without any penalty or obllgation, wlthln three business days from tho +tbove date. If you cancel, any proporty traded In, any payment made by you under contract or sale, and any negotiable Instrument executed by you will be returned within t0 business days following receipt by the Sailor of your cancellation notice, and any security Interest arlaing out of the transactlon will be cancelled. If you cancel, you must make available to the sellar at your rusidonco, In substantially as good condition as when received, any goods dollvered to you under this contract or sale: or you may, If you wish, comply with the Instruction& of the seller regarding the return shipment of the goods at the seller's axpenso and risk. If you do make the goads available to the seller and the seller duos not pick them up within 20 days of the data of your Notice of Cancellation, you may retain or dispose of the goads without any further obligation. If you fall to make the goods available to the seller or If you agree to return the goods to the seller and fail to d° aa, than you remain liable for performance of al( obligations under the contract Tocancel this transaction, mall or deliver a signed and dated copy of this cancellation notice or any other written notice, or send a telegram to ehamaanne Paul of Cnntol Florida Inc 54 7 nc p& ane, Sulte # 1 Sanford. Fronds 32773, NO LATER THAN MIDNIGHT ON I HEREBY CANCEL THIS TRANSACTION DATE: OWNER'S SIGNATURE TO CANCEL: - Only sign Ir you are canceling this transaction)