HomeMy WebLinkAbout114 Park Ave (2)e
a.
BY,
CITY OF SANFORD.
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
C..
Application No: 1 O ` Documented Construction Value: $ . a
Job Address: f /s2k Roe ; Historic District: Yes No
Parcel ID: Zoning:
3
Description of Work:
Plan Review Contact Person: '.L1 t /2 =GC> t7d.r c..b Six) Title: m n rz
Phone: LID 7, -719 - 3096 Fax: q6 7.3 z / E-mail:.
14
Property Owner Information -
Name ®KA ?20 p8/LT) s Phone: 0/07- 2 Z I — 9f9 J
Street: S', 9 re d 2_ Resident of property? : e5
City, State Zip: LA,--e YOA/2 i L `I2
Contractor Information
Name C- R /c, C, L_ C Phone: -7 30
Street: % D (1 Ae' _'1 2tP eA f oD cl Fax: ` ' 7 " ag 3 <1t
City, State Zip: &,I / T G1'9 n i 3 2-751 State License No.:
Architect/Engineer Information
Name: 2j6AJ7"Z®&, 4D l Phone: 3S 2 Zy 7 — d !D o
Street: •2 q D 2 9 -ram I-s L-Je it t3c.y Fax: Z; L4 Z - 030 Z
City, St, Zip: L 2 L 3 "? 1 / E-mail:
Bonding Company: Mortgage Lender:
Address: Address:
PERMIT INFORMATION
Building Permit
Square Footage: Construction Type:
No. of Dwelling Units:
Electrical
New Service - No. of AMPS:
No. of Stories:
Flood Zone:
Plumbing '
Mechanical E (Duct layout required for new systems)
YAW Hem i " _5' 0 /0'0S. &/L
New Construction - No. of Fixtures:
Fire Sprinkler/Alarm No. of heads:
P°'
if
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no
work or installation has commenced prior to the' issuance .of a permit and that all work will be performed to
meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit
must be secured for electrical work, plumbing, signs, wells, ;pools, furnaces, boilers, heaters, tanks, and
air conditioners,, etc. '
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR`AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this
property that may be found in the public records of this county, and there may be additional permits required
from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida
Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order
to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the
plan review -fee based on past permit activity levels. Should calculated charges exceed the documented
construction value when the executed contract is submitted, credit will be applied to your permit fees when the
permit is released.
71 of Contractor/Agent Date
Print Contractor/Agent's Name
Signature of Notary -ate UTlorida m ° ••.'oDate
O:uN ,• 6
0.
e
ssAnuepa4 Contractor/
Agent i *r N, Personally Known to Me or Produced
ID Type of ID F L `, APPROVALS:
ZONING: 40a'Zoll UTILITIES: IV
Signature
of Owner/Agent Print
Owner/Agent's Name Date
Signature
of Notary -State of Florida Date Owner/
Agent is Personally Known to Me or Produced
ID Type of ID ENGINEERING:
COMMENTS:
WASTE
WATER: BUILDING:
Rev
11.08
Seminole County Property Appraiser Get Information by Parcel Number Page I of 1
PARCEL DETAIL
D^viD Jo, NsoN. CFA.ASA
3.0
a 4
22
4.
0 PROPERTY
4iPPRAISER.
SEMINGLE
COUNTY A
4.A UJ
03041T lu -0303- X
X 76-0 eel -
A
FL
1101
E.FIRSTST U) InSAKFoRa.
FL32771-14sa W
2ND ST E2NDST 407 - 6!Zs77soa F_
eo-_1 F o--,] r ;L FRI .5 VALUE
SUMMARY VALUES
2011 2010 Working
Certified GENERAL
Value Method Cost/Market Cost/Market Parcel
Id: 25-19-30-5AG-0304-009A Number of Buildings 1 1 Owner:
ROKA PROPERTIES INC Depreciated
Bldg Value 259,126 265,266 Mailing
Address: 856 SILVERWOOD DR Depreciated EXFT Value 0 0 Clty,
State,ZIpCode: LAKE MARY FL 32746 Land Value (Market) 26,325 26,325 Property
Address: 114 PARK AVE Land
Value Ag 0 0 Facility
Name: THE ALLEY Just/
Market Value 285,451 291,591 Tax
District: S3-SANFORD-WATERFRONT REDVDST Portablity
AdJ 0 0 Exemptions: Save
Our Homes AdJ 0 i_0 Dor. 1802-TWO STORY OFFICE BLD Amendment
I AdJ 0 0 Assessed
Value (SOH) 285,451 291,591 Tax
Estimator 2011
TAXABLE VALUE WORKING ESTIMATE Taxing
Authority Assessment Value Exempt Values Taxable Value County
General Fund 285,451 0 285,451 Amendment
1 adjustment Is not applicable to school assessment) Schools 285,451 0 285,451 City
Sanford 285,451 0 285,451 SJWM(
SaInt Johns Water Management) 285,451 0 285,451 County
Bonds 285,4511 0! 285,4511 The
taxable values and taxes are calculated using the current years working values and the prior years approved millage rates. SALES
2010
VALUE SUMMARY Deed
Date Book Page Amount Vaclimp Qualified WARRANTY
DEED 12/2002 04661 0630 $350,000 Improved No 2010
Tax Bill Amount: $5,857 WARRANTY
DEED 01/2000 03783 1743 $68,000 Improved No 2010
Certified Taxable Value and Taxes DOES
NOT INCLUDE NON -AD VALOREM ASSESSMENTS Find
Sales within this DOR Code LEGAL
DESCRIPTION LAND
Land
Assess Method Frontage Depth Land Units Unit Price Land Value PLATS: Pick... - SQUARE
FEET - 0 0 5,265 5.00 $26,325 LEG S 15.73 FT OF LOT 9 + N 29.27 FT OF LOT 10 BLK 3 TR 4
TOWN OF SANFORD PB 1 PIS 68 BUILDING
INFORMATION Bid
Num Bid Class Year Bit Fixtures Gross SF Stories Ext Wall Bid Value Est Cost New 1
MASONRY PILAS 1901 19 7,320 2 BRICK COMMON -MASONRY $259,126 $569,508 Subsection
I Sqft OPEN PORCH FINISHED/ 42 Subsection /
Sqft OPEN PORCH FINISHED/ 18 Subsection
I Sqft CANOPY / 450 Subsection
Sqft CANOPY / 450 Permits
NOTE:
Assessed values shown are NOT ceriffled values and therefore are subject to change before being finalized for ad valorem tax purposes. I-
ffyou recentfy purchased a homesteaded property your next year's property tax will be based on Just/Market value. http://
Www.scpafl.org/web/re—web.seminole—county_title?parcel=2519305AGO304009A&... 3/23/2011
Florida Energy Efficiency Code For Building Construction
Florida Department of Community Affairs
EnergyGauge Summit® Fla/Com-2008, Effective: March 1, 2009 -- Form 40OB-2008
Method B: Prescriptive Compliance for Renovations, Occupancy Change, etc.
PROJECT SUMMARY
Short Desc: New Prj Description: Alley Bar
Owner: Alley Bar
Addressl: 114 Park Ave. City: Sanford
Address2: State: Florida
Zip: 32771
Type: Dining: Bar Lounge/Leisure Class: Renovation to existing buildi
Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500)
Conditioned Area: 2592 SF Conditioned & UnConditioned Area: 2592 SF
No of Stories: 1 Area entered from Plans 2592 SF
Permit No: 0 Max Tonnage 5
If different, write in:
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/28/2011 Page 1 of 7
d
Compliance Summary
11 Component Design Criteria Result 11
RENOVATED ENVELOPE PRESCRIPTIVE
LIGHTING POWER
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
1.0
PASSES
3,110.4 PASSES
PASSES
None Entered
PASSES
None Entered
None Entered
None Entered
Yes/No/NA
IMPORTANT MESSAGE
Info 5009 -- -- -- An input report of this design building must be submitted along with this
Compliance Report
2/28/2011
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
Page 2 of 7
CERTIFICATIONS
I hereby certify that the plans and specifications covered by this calculation are in compliance with the
Florida Energy Code
Prepared By: Robert Wessling Building Official:
Date: Date:
I certify that this building is in compliance with the Florida Energy Efficiency Code
Owner Agent: Date:
If Required by Florida law, I hereby certify (") that the system design is in compliance with the FLorida
Energy Efficiency Code
Architect: Reg No:
Electrical Designer: Reg No:
Lighting Designer: Reg No:
Mechanical Designer: Reg No:
Plumbing Designer: Reg No:
Signature is required where Florida Law requires design to be performed by registered design
professionals.
Project: New Prj
Title: Alley Bar
Type: Dining: Bar Lounge/Leisure
WEA File: FL_ORLANDO_SANFORD AIRPORT.tm3)
Prescriptive Envelope Compliance
Item Zone Description Design Criteria Meet Req.
Glass PrOZol Percent glass Max allowed .000 50.000 Yes
Skylights PrOZol Percent Skylight Max allowed .000 5.000 Yes
Meets Shell Envelope Requirements -- PASSES
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/28/2011 Page 3 of 7
External Lighting Compliance
Description Category Tradable? Allowance Area or Length ELPA CLP
W/Unit) or No. of Units (W) (W)
Sgft or ft)
None
Project: New Prj
Title: Alley Bar
Type: Dining: Bar Lounge/Leisure
WEA File: FL_ORLANDO_SANFORD AIRPORT.tm3)
Lighting Power Compliance
Space Ashrae Description Area Height No. of Design Effective Allowance
ID (sq.ft) (ft) Spaces (W) (W) (W)
PrOZo1Sp1 9 Food Service - Bar/Lounge 2,592 9.0 1 1 1 3,110
Design 1 (W) PASSES
Effective: 1 (W)
Allowance: 3110.4 (W)
Passing requires Design to be at most 100% of Criteria
Project: New Prj
Title: Alley Bar
Type: Dining: Bar Lounge/Leisure
WEA File: FL ORLANDO SANFORD AIRPORT.tm3)
Lighting Controls Compliance
Acronym Ashrae Description Area Design Min Compli-
ID (sq.ft) CP CP ance
Pr0Zo1Spl 9 Food Service - Bar/Lounge 2,592 2 2 PASSES
PASSES
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/28/2011 Page 4 of 7
Project: New Prj
Title: Alley Bar
Type: Dining: Bar Lounge/Leisure
WEA File: FL_ORLANDO_SANFORD AIRPORT.tm3)
System Report Compliance
PrOSyl System 1 Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System
Heating System
Air Handling
System -Supply
Air Conditioners Air Cooled 13.00 12.23 8.00 PASSES
Split System < 65000 Btu/h
Cooling Capacity
Electric Furnace 1.00 1.00 PASSES
Air Handler (Supply) - 0.80 0.90 PASSES
Constant Volume
PASSES
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
None
Water Heater Compliance
Description Type Category
Design Min Design Max Comp
Eff Eff Loss Loss liance
None
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/28/2011 Page 5 of 7
Piping System Compliance
Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
F] .SF.F]
None
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/28/2011 Page 6 of 7
Project: New Prj
Title: Alley Bar
Type: Dining: Bar Lounge/Leisure
WEA File: FL ORLANDO_SANFORD_AIRPORT.tm3)
Other Required Compliance
Category Section Requirement (write N/A in box if not applicable) Check
Report 13-101 Input Report Print -Out from EnergyGauge FlaCom attached
Operations Manual 13-102.1, Operations manual provided to owner
13-410,13-413
Windows & Doors 13-406.AB.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfin/ftz; all
other products: 0.4 cfin/ftz
Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed
Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof &
side walls
System 13-407 HVAC Load sizing has been performed
Reheat 13-407.B Electric resistance reheat prohibited
HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.3.2.1A-D;
Heating Tables 13-407.AB.3.2.1B, 13-407.AB.3.2.1D,
13-408.AB.3.2.1E, 13-408.AB.3.2F
HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating
and cooling in each zone; combined HAC deadband of at least 5°F
exceptions)
Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) exhaust
systems and 2) systems with design outside air intake or exhaust
capacity <_300 cfm
ADS 13-410 Duct sizing and Design have been performed
HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall
be mechanically attached, sealed, insulated & installed per Sec.
13-410 Air Distribution Systems
Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in
construction documents
Piping Insulation 13-41 LAB In accordance with Table 13-41 LAB.2
Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3.
Heat trap required
Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions);
Readily accessible on/off switch
Hot Water Pipe 13-41 LAB.3 Table 13-41 LAB.2 for circulating systems, first 8 feet of outlet El
Insulation pipe from storage tank and between inlet pipe and heat trap
Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public
lavatory fixture how water flow 0.5 gpm max; if self -closing valve
0.25 gallon recirculating, 0.5 gallon non recirculating
Motors 13-414 Motor efficiency criteria have been met
Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000
s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or
3 linear fluuorescent lamps>30W
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/28/2011 Page 7 of 7
Print Page 1 of 1
From: Fabian Garcia (fgarcial90@aol.com)
To: ldonaldsonl 122@att.net;
Date: Wed, March 9, 2011 11:11:03 AM
Cc:
Subject: Fwd: Air Conditioning Estimate
Original Message —
From: fgarcia190 <fgarcia190@aol.com>
To: robh <robh@insuranceriskservices.com>
Sent: Fri, Sep 24, 2010 6:55 pm
Subject: Air Conditioning Estimate
Hello Rob,
Just wanted to once again apologize for being so late getting this to you.
This quote will include the following;
Goodman Air Handler
Model# Aruf486016b
Goodman Straight Cool Condenser
Model# Gsx130601 b
Ductwork to include 6 supply drops and 1 return drop. Each bathroom will receive a drop, and the pool table area
will have 4 supply drops and 1 return drop.
As mentioned in our conversation earlier electrical work will not be included. Our equipment requires 220v to both
inside and outside units.
Total price for this 4 ton system and ductwork will be $5950.00. If you decide to do this I anticipate the work taking
about 2 days. Thanks once again for your time and also am very sorry I forgot about you.
Fabian Garcia
B&L A/C Service LLC
Managing Member
Sent from my HTC on the Now Network from Sprint!
http://us.mg203.mail.yahoo.com/dc/launch?.partner=sbc&.gx=1&.rand=bgdOgfn987s60 3/9/2011
Fenestration Used
Name Glass Type No. of
Glass
SHGC VLT
Panes
Conductance
Btu/h.sf.F]
Materials Used
Only R-Value RValue Thickness Conductivity Density SpecificHeat
Mat No Acronym Description
Used [h.sf.FBtu] [ft] Btu/h.ft.F] lb/cf] Btu/lb.F]
178 Matl 17 8 CARPET WIRU13BER PAD Yes
265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000
48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000
Constructs Used
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu]
1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7
Layer Material Material Thickness Framing
No. ft] Factor
1 265 Soil, 1 ft 1.0000 0.000
2 48 6 in. Heavyweight concrete 0.5000 0.000
3 178 CARPET W/RUBBER PAD 0.000
2/28/2011 EnergyGauge Summit® v3.22
Project Name: New Prj
Project Title: Alley Bar
Address: 114 Park Ave.
State: Florida
Zip: 32771
Owner: Alley Bar
EnergyGauge Summit® v3.22
INPUT DATA REPORT
Project Information
Orientation: East
Building Type: Dining: Bar Lounge/Leisure
Building Classification: Renovation to existing building
No.of Stories: 1
GrossArea: 2592 SF
Zones
No Acronym Description Type Area
sfl
Multiplier Total Area
sfl
1 PrOZo I Zone 1 CONDITIONED 2592.0 1 2592.0
Spaces
No Acronym Description Type Depth
IN
Width Height Multi
IN [ftl plier
Total Area
sf]
Total Volume
cf]
2/28/2011 EnergyGauge Summit® Q.22 1
In Zone: PrOZol
1 Pr0Zo1Sp1 Zo0Sp1 Food Service - Bar/Lounge 96.00 27.00 9.00 1 2592.0 23328.0
Lighting
No Type Category No. of Watts per Power Control Type No.of
Luminaires Luminaire W] Ctrl pts
In Zone: PrOZol
In Space: Pr0Zo1Sp1
1 Recessed Fluorescent - General Lighting 1 1 1 Manual On/Off 2
No vent
Walls
No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value
IN [ft] plier [sf] Btu/hr. sf. F] Capacity Ib/cf] [h.sf.FBtu]
Btu/sf.F]
In Zone:
Windows
No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area
Btu/hr sf F] IN [ft] plier sf]
In Zone:
In Wall:
El
Doors
No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value
IN [ft] plier sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu]
In Zone:
In Wall:
2/28/2011 EnergyGauge Summit® v3.22
Roofs
No Description Type Width H (Effec) Multi
ft] IN plier
Area
sf]
Tilt Cond. Heat Cap Dens. R-Value
deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu]
In Zone:
Skylights
No Description Type U SHGC Vis.Trans
Btu/hr sf F]
W H (Effec) Multiplier
ft] [ft]
Area Total Area
Sf] [Sf]
In Zone:
In Roof:
El
Floors
No Description Type Width H (Effec) Multi
ft] [ft] plier
Area
sf]
Cond. Heat Cap. Dens.
Btu/hr. sf. F] [Btu/sf. F] [Ib/cf]
R-Value
h.sf.F/Btu]
In Zone: PrOZol
1 Pr0Zo1F11 1 ft. soil, concrete
floor, carpet and
rubber pad
27.00 96.00 1 2592.0 0.2681 34.00 113.33 3.73
Systems
PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1
System < 65000 Btu/hr
Component Category Capacity Efficiency IPLV
2/28/2011 EnergyGauge Summit® v3.22
I Cooling System
2 Heating System
3 Air Handling System -Supply
60000.00
34100.00
1500.00
13.00 8.00
1.00
0.80
Plant
Equipment Category Size Inst.No Eff. IPLV
UJI
Water Heaters
W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss
Ext-Lighting
Description Category No. of Watts per Area/Len/No. of units
Luminaires Luminaire [sf/ft/No]
Control Type Wattage
W]
El
Piping
No Type Operating Insulation
Temperature Conductivity
F] [ Btu-in/h.sf.F]
Nomonal pipe
Diameter
in]
Insulation Is Runout?
Thickness
in]
El
2/28/2011 EnergyGauge Summit® v3.22
t
Fenestration Used
Name Glass Type No. of
Glass
SHGC VLT
Panes
Conductance
Btu/h.sf.F]
Materials Used
Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat
Used [h.sf.F/Btu] [11] Btu/h.ft.F] lb/cf] Btu/lb.F]
179 at es 1.2300
265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000
48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000
Constructs Used
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu]
1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7
Layer Material Material Thickness Framing
No. ft] Factor
1 265 Soil, 1 ft 1.0000 0.000
2 48 6 in. Heavyweight concrete 0.5000 0.000
3 178 CARPET W/RUBBER PAD 0.000
2/28/2011 EnergyGauge Summit® v3.22
r,
J
Project Name: New Prj
Project Title: Alley Bar
Address: 114 Park Ave.
State: Florida
Zip: 32771
Owner: Alley Bar
EnergyGauge Summit® v3.22
INPUT DATA REPORT
Proiect Information
Orientation: East
Building Type: Dining: Bar Lounge/Leisure
Building Classification: Renovation to existing building
No.of Stories: 1
GrossArea: 2592 SF
Zones
No Acronym Description Type Area
s11
Multiplier Total Area
lsfl
1 PrOZoI Zone I CONDITIONED 2592.0 1 2592.0
Spaces
No Acronym Description Type Depth
lftl
Width Height Multi
IN lftl plier
Total Area
lsfl
Total Volume
lell
2/28/2011 EnergyGauge Summit® v3.22 1
In Zone: PrOZol
1 PrOZo1Sp1 Zo0Sp1 Food Service - Bar/Lounge 96.00 27.00 9.00 1 2592.0
1,
23328.0
Lighting
i'
No Type Category No. of Watts per Power Control Type No.of
Luminaires Luminaire W] Ctrl pts
In Zone: PrOZol
In Space: Pr0Zo1Sp1
1 Recessed Fluorescent General Lighting 1 1 1 Manual On/Off 2
No vent
Walls
No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value
ft] [ft] plier [sf] Btu/hr. sf. F] Capacity lb/cf] [h.sf.F/Btu]
Btu/sf.F]
In Zone:
Windows
No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area
Btu/hr sf F] IN [ft] plier sf]
In Zone:
In Wall:
Doors
No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value
ft] [ft] plier sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu]
In Zone:
In Wall:
2/28/2011 EnergyGauge Summit® v3.22
Roofs
No Description Type Width H (Effec) Multi
ft] [ft] plier
Area
sf]
Tilt Cond. Heat Cap Dens. R-Value
deg] [Btu/hr. SE F] [Btu/sf. Fl [lb/cf] [h.sf.FBtu]
In Zone:
Skylights
No Description Type U SHGC Vis.Trans
Btu/hr sf F]
W H (Effec) Multiplier
ft] [ft]
Area Total Area
Sf] [Sf]
In Zone:
In Roof:
El
Floors
No Description Type Width H (Effec) Multi
ft] [ft] plier
Area
sf]
Cond. Heat Cap. Dens.
Btu/hr. sf. F] [Btu/sf. F] [Ib/cq
R-Value
h.sf.FBtu]
In Zone: PrOZol
1 Pr0Zo1F11 1 ft. soil, concrete
floor, carpet and
rubber pad
27.00 96.00 1 2592.0 0.2681 34.00 113.33 3.73
Systems
PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1
System < 65000 Btu/hr
Component Category Capacity Efficiency IPLV
2/28/2011 EnergyGauge Summit® v3.22
I Cooling System
2 Heating System
3 Air Handling System -Supply
60000.00
34100.00
1500.00
13.00 8.00
1.00
0.80
El
Plant
Equipment Category Size Inst.No Eff. IPLV
Water Heaters
W-Heater Description Capacit3Cap.Unit UP Rt. Efficiency Loss
Ext-Lighting
Description Category No. of Watts per Area/Len/No. of units
Luminaires Luminaire [sf/ft/No]
Control Type Wattage
W]
El
Piping
No Type Operating Insulation
Temperature Conductivity
F] [ Btu-in/h.sf.F]
Nomonal pipe
Diameter
in]
Insulation Is Runout?
Thickness
in]
El
2/28/2011 EnergyGauge Summit® v3.22
Fenestration Used
Name Glass Type No. of
Glass
SHGC VLT
Panes
Conductance
Btu/h.sf.F]
Materials Used
Only R-Value RValue Thickness Conductivity Density SpecificHeat
Mat No Acronym Description
Used [h.sf.F/Btu] [11] Btu/h.ft.F] lb/cf] Btu/lb.F]
178 at es
265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000
48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000
Constructs Used
Simple Massless Conductance Heat Capacity Density RValue
No Name
Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu]
1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7
Layer Material Material Thickness Framing
No. ft] Factor
1 265 Soil, 1 ft 1.0000 0.000
2 48 6 in. Heavyweight concrete 0.5000 0.000
3 178 CARPET W/RUBBER PAD 0.000
2/28/2011 EnergyGauge Summit® v3.22
System/Area Pleating and Cooling Load Summary Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB
System -Wide Max. Cool Load Time: September at 4:00 PM
Total Sensible Total Total Summer Winter Area Maximum
Qty Area Cooling Cooling Heating CFM CFM Cooling Load Time
Zone Name: Rear of building
Rear 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 September at 4:00 PM
Room Totals by Zone: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Room Totals by System: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
AddYl Coil Totals: 12,249.2 26,820.5 20,470.9
Total Loads by System: 27,553.8 49,815.2 23,107.8
Total Tonnage: 4.2
Room Grand Totals: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Addt9 Coil Grand Totals: 12,249.2 26,820.5 20,470.9
Grand Totals: 27,553.8 49,815.2 23,107.8
Total Tonnage: 4.2
P,
System/Area Heating and Cooling Load' Summary Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB
System -Wide Max. Cool Load Time: August at 10:00 AM
Total Sensible Total Total Summer Winter Area Maximum
city Area Cooling Cooling Heating CFM CFM Cooling Load Time
Zone Name: Bar area
Main bar 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 August at 10:00 AM
Room Totals by Zone: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Room Totals by System: 1 1.365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Addfl Coil Totals: 6,962.7 14,278.8 10,917.8
Total Loads by System: 41,933.5 54,614.4 18,871.1
Total Tonnage: 4.6
Room Grand Totals: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Addfl Coil Grand Totals: 6,962.7 14,278.8 10,917.8
Grand Totals: 41,933.5 54,614.4 18,871.1
Total Tonnage: 4.6
Breakdown of All Load Components Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB
System SgFt: 1,200.0 Max. Cool Load Time: September at 4:00 PM
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wall Load 243.0 SgFt 1,006.3 1,006.3 2.0% 2,207.6
Window Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Door Load 20.0 SgFt 138.5 138.5 0.3% 303.8
People Load 60.0 People 10,927.2 6,30O.0 17,227.2 34.6% 0.0
Lighting Load 720.0 Wafts 1,486.0 1,486.0 3.0% 0.0
Electrical Load 600.0 Wafts 1,017.9 1,023.9 2,041.8 4.1% 0.0
Partition Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 728.8 366.2 1.095.0 2.2% 125.6
Subtotal 15,304.6 7,690.1 22,994.7 46.2% 2,636.9
Cool Ventilation Load 600.0 CFM 11,786.3 14,571.2 26,357.5 52.9%
Heat Ventilation Load 600.0 CFM 20,470.9
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 463.0 463.0 0.9%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 27,553.8 22,261.3 49,815.2 100.0% 23,107.8
e.
Breakdown of All Load Components Page 2
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: Existing Outside Temperature: 94.OF DB / 76.017 WB
System SgFt: 1,365.0 Max. Cool Load Time: August at 10:00 AM
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wall Load 243.0 SgFt 850.3 850.3 1.6% 1,039.5
Window Load 138.0 SgFt 19,962.0 19,962.0 36.6% 3,643.2
Door Load 0.0 SgFt 0.0 0.0 0.0% 0.0
People Load 40.0 People 8,734.3 4,200.0 12,934.3 23.7% 0.0
Lighting Load 819.0 Watts 2,327.0 2,327.0 4.3% 0.0
Electrical Load 682.5 Watts 1,106.5 1,164.7 2,271.1 4.2% 0.0 ,
Partition Load 1,580.0 SgFt 1,990.8 1,990.8 3.6% 3,270.6
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 0.0 0.0 0.0 0.0% 0.0
Subtotal 34,970.8 5,364.7 40,335.5 73.9% 7,953.3
Cool Ventilation Load 320.0 CFM 5,955.2 7,316.2 13,271.3 24.3%
Heat Ventilation Load 320.0 CFM 10,917.8
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 1,007.5 1,007.5 1.8%
Dud Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 41,933.5 12,680.9 54,614.4 100.0% 18,871.1
MA
Breakdown of All Load Components Page 3
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: All Systems Outside Temperature: 94.OF DB / 76.OF WB
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0°% 0.0
Wall Load 486.0 SgFt 1,856.6 1,856.6 1.8% 3,247.1
Window Load 138.0 SgFt 19,962.0 19,962.0 19.1% 3,643.2
Door Load, 20.0 SgFt 138.5 138.5 0.1 °% 303.8
People Load 100.0 People 19,661.5 10,500.0 30,161.5 28.9% 0.0
Lighting Load 1,539.0 Watts 3,813.0 3,813.0 3.7% 0.0
Electrical Load 1,282.5 Watts 2,124.3 2,188.6 4,312.9 4.1% 0.0
Partition Load 1,580.0 SgFt 1,990.8 1,990.8 1.9% 3,270.6
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0°% 0.0
Safety Factors 728.8 366.2 1,095.0 1.0% 125.6
Subtotal 50,275.4 13,054.8 63,330.2 60.6°% 10,590.2
Cool Ventilation Load 920.0 CFM 17,741.4 21,887.4 39,628.9 37.9%
Heat Ventilation Load 920.0 CFM 31,388.7
Plenum Load 0.0 0.0 0.0°%
Fan Heat Load 1.470.5 1,470.5 1.4°%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 69,487.3 34,942.2 104,429.5 100.0% 41,978.9
1`
System/Area Heating and Cooling Load Summary Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB
System -Wide Max. Cool Load Time: September at 4:00 PM
Total Sensible Total Total Summer Winter Area Maximum
sty Area Cooling Cooling Heating CFM CFM Cooling Load Time
Zone Name: Rear of building
Rear 1 1,200.0 15,304.6 22,994.7 2,636.9, 740.2 600.0 September at 4:00 PM
Room Totals by Zone: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Room Totals by System: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Addt'I Coil Totals: 12,249.2 26,820.5 20,470.9
Total Loads by System: 27.553.8 49,815.2 23,107.8
Total Tonnage: 4.2
Room Grand Totals: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Addt9 Coil Grand Totals: 12,249.2 26,820.5 20,470.9
Grand Totals: 27,553.8 49,815.2 23,107.8
Total Tonnage: 4.2
System/Area Heating and Cooling Load Summary Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: Existing Outside Temperature: 94.017 DB / 76.OF WB
System -Wide Max. Cool Load Time: August at 10:00 AM
Total Sensible Total Total Summer Winter Area Maximum
Qty Area Cooling Cooling Heating CFM CFM Cooling Load Time
Zone Name: Bar area
Main bar 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 August at 10:00 AM
Room Totals by Zone: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Room Totals by System: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Addt9 Coil Totals: 6,962.7 14,278.8 10,917.8
Total Loads by System: 41,933.5 54,614.4 18,871.1
Total Tonnage: 4.6
Room Grand Totals: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Addfl Coil Grand Totals: 6,962.7 14,278.8 10,917.8
Grand Totals: 41,933.5 54,614.4 18,871.1
Total Tonnage: 4.6
Breakdown of AII'Load Components Page 1
2/21/2011
Lindemann, Benlzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB
System SgFt: 1,200.0 Max. Cool Load Time: September at 4:00 PM
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wall Load 243.0 SgFt 1,006.3 1,006.3 2.0% 2,207.6
Window Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Door Load 20.0 SgFt 138.5 138.5 0.3% 303.8
People Load 60.0 People 10,927.2 6,300.0 17,227.2 34.6% 0.0
Lighting Load 720.0 Watts 1,486.0 1,486.0 3.0% 0.0
Electrical Load 600.0 Watts 1,017.9 1,023.9 2,041.8 4.1% 0.0
Partition Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 728.8 366.2 1,095.0 2.2% 125.6
Subtotal 15,304.6 7,690.1 22,994.7 46.2% 2,636.9
Cool Ventilation Load 600.0 CFM 11,786.3 14,571.2 26,357.5 52.9%°
Heat Ventilation Load 600.0 CFM 20,470.9
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 463.0 463.0 0.9%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 27,553.8 22,261.3 49,815.2 100.0% 23,107.8
Breakdown of All Load Components Page 2
2/2112011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB
System SgFt: 1,365.0 Max. Cool Load Time: August at 10:00 AM
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgF.t 0.0 0.0 0.0% 0.0
Wall Load 243.0 SgFt 850.3 850.3 1.6% 1,039.5
Window Load 138.0 SgFt 19,962.0 19,962.0 36.6% 3,643.2
Door Load 0.0 SgFt 0.0 0.0 0.0% 0.0
People Load 40.0 People 8,734.3 4,200.0 12,934.3 23.7% 0.0
Lighting Load 819.0 Watts 2,327.0 2,327.0 4.3% 0.0
Electrical Load 682.5 Watts 1,106.5 1,164.7 2,271.1 4.2% 0.0
Partition Load 1,680.0 SgFt 1,990.8 1;990.8 3.6% 3,270.6
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 0.0 0.0 0.0 0.0% 0.0
Subtotal 34,970.8 5,364.7 40,335.5 73.9% 7,953.3
Cool Ventilation Load 320.0 CFM 5,955.2 7,316.2 13,271.3 24.3%
Heat Ventilation Load 320.0 CFM 10,917.8
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 1,007.5 1,007.5 1.8%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 41,933.5 12,680.9 54,614.4 100.0% 18,871.1
Breakdown of All Load'Components Page 3
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida.34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: All Systems Outside Temperature: 94.OF DB / 76.OF WB
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wall Load 486.0 SgFf 1,856.6 1,856.6 1.8% 3,247.1
Window Load 138.0 SgFt 19,962.0 19,962.0 19.1% 3,643.2
Door Load 20.6 SgFt 138.5 138.5 0.1% 303.8
People Load 100.0 People 19,661.5 10,500.0 30,161.5 28.9% 0.0
Lighting Load 1,539.0 Watts 3,813.0 3,813.0 3.7% 0.0
Electrical Load 1,282.5 Watts 2,124.3 2,188.6 4.312.9 4.1% 0.0
Partition Load 1,580.0 SgFt 1,990.8 1,990.8 1.9% 3,270.6
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 728.8 366.2 1,095.0 1.0% 125.6
Subtotal 50,275.4 13,054.8 63,330.2 60.6% 10,590.2
Cool Ventilation Load 920.0 CFM 17,741.4 21,887.4 39,628.9 37.9%
Heat Ventilation Load 920.0 CFM 31,388.7
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 1,470.5 1,470.5 1.4%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 69,487.3 34,942.2 104,429.5 100.0% 41,978.9
3
System/Area Heating and Cooling Load Summary Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: A/C-1 Outside Temperature: 94.OF DB / 76.017 WB
System -Wide Max. Cool Load Time: September at 4:00 PM
Total Sensible Total Total Summer Winter Area Maximum
qty Area Cooling Cooling Heating CFM CFM Cooling Load Time
Zone Name: Rear of building
Rear 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 September at 4:00 PM
Room Totals by Zone: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Room Totals by System: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
AddYl Coil Totals: 12,249.2 26,820.5 20,470.9
Total Loads by System: 27,553.8 49,815.2 23,107.8
Total Tonnage: 4.2
Room Grand Totals: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0
Addrl Coil Grand Totals: 12,249.2 26,820.5 20,470.9
Grand Totals: 27,553.8 49,815.2 23,107.8
Total Tonnage: 4.2
System/Area Heating and Cooling Load Summary Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB
System -Wide Max. Cool Load Time: August at 10:00 AM
Total Sensible Total Total Summer Winter Area Maximum
City Area Cooling Cooling Heating CFM CFM Cooling Load Time
Zone Name: Bar area
Main bar 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 August at 10:00 AM
Room Totals by Zone: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Room Totals by System: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Addt9 Coil Totals: 6,962.7 14,278.8 10,917.8
Total Loads by System: 41,933.5 54,614.4 18,871.1
Total Tonnage: 4.6
Room Grand Totals: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0
Addt9 Coil Grand Totals: 6,962.7 14,278.8 10,917.8
Grand Totals: 41,933.5 54,614.4 18,871.1
Total Tonnage: 4.6
Breakdown of All Load Components Page 1
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: A/C-1 Outside Temperature: 94.OF DB / 76.017 WB
System SgFt: 1,200.0 Max. Cool Load Time: September at 4:00 PM
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wall Load 243.0 SgFt 1,006.3 1,006.3 2.0% 2,207.6
Window Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Door Load 20.0 SgFt 138.5 138.5 0.3% 303.8
People Load 60.0 People 10,927.2 6,300.0 17,227.2 34.6% 0.0
Lighting Load 720.0 Watts 1,486.0 1,486.0 3.0% 0.0
Electrical Load 600.0 Wafts 1,017.9 1,023.9 2,041.8 4.1% 0.0
Partition Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 728.8 366.2 1,095.0 2.2% 125.6
Subtotal 15,304.6 7,690.1 22,994.7 46.2% 2,636.9
Cool Ventilation Load 600.0 CFM 11,786.3 14,571.2 26,357.5 52.9%
Heat Ventilation Load 600.0 CFM 20,470.9
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 463.0 463.0 0.9%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 27,553.8 22,261.3 49,815.2 100.0% 23,107.8
Breakdown of All Load Components Page 2
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB
System SgFt: 1,365.0 Max. Cool Load Time: August at 10:00 AM
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wall Load 243.0 SgFt 850.3 850.3 1.6% 1,039.5
Window Load 138.0 SgFt 19.962.0 19,962.0 36.6% 3,643.2
Door Load 0.0 SgFt 0.0 0.0 0.0% 0.0
People Load 40.0 People 8,734.3 4,200.0 12,934.3 23.7% 0.0
Lighting Load 819.0 Watts 2,327.0 2,327.0 4.3% 0.0
Electrical Load 682.5 Watts 1,106.5 1,164.7 2,271.1 4.2% 0.0
Partition Load 1,580.0 SgFt 1,990.8 1,990.8 3.6% 3,270.6
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 0.0 0.0 0.0 0.0% 0.0
Subtotal 34.970.8 5,364.7 40,335.5 73.9% 7,953.3
Cool Ventilation Load 320.0 CFM 5,955.2 7,316.2 13,271.3 24.3%
Heat Ventilation Load 320.0 CFM 10,917.8
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 1,007.5 1,007.5 1.8%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 41,933.5 12,680.9 54,614.4 100.0% 18,871.1
Breakdown of All Load Components Page 3
2/21/2011
Lindemann, Bentzon, Bojack Engineering
290 Citrus Tower Blvd.
Clermont, Florida 34712
Building Name: Alley Bar Location: Orlando, Florida
System Name: All Systems Outside Temperature: 94.OF DB / 76.OF WB
Description Units Sensible Latent Total of Total Heating
Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Wail Load 486.0 SgFt 1,856.6 1,856.6 1.8% 3,247.1
Window Load 138.0 SgFt 19,962.0 19,962.0 19.1% 3,643.2
Door Load 20.0 SgFt 138.5 138.5 0.1% 303.8
People Load 100.0 People 19,661.5 10,500.0 30,161.5 28.9% 0.0
Lighting Load 1,539.0 Watts 3,813.0 3,813.0 3.7% 0.0
Electrical Load 1,282.5 Watts 2,124.3 2,188.6 4.312.9 4.1% 0.0
Partition Load 1,680.0 SgFt 1,990.8 1,990.8 1.9% 3,270.6
Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0
Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0
Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0
Safety Factors 728.8 366.2 1,095.0 1.0% 125.6
Subtotal 50,275.4 13,054.8 63,330.2 60.6% 10,590.2
Cool Ventilation Load 920.0 CFM 17,741.4 21,887.4 39,628.9 37.9%
Heat Ventilation Load 920.0 CFM 31,388.7
Plenum Load 0.0 0.0 0.0%
Fan Heat Load 1,470.5 1,470.5 1.4%
Duct Heat Load 0.0 0.0 0.0% 0.0
Reheat Load 0.0 0.0 0.0%
Coil Load 0.0 0.0 0.0%
Total Loads 69,487.3 34,942.2 104,429.5 100.0% 41,978.9