Loading...
HomeMy WebLinkAbout114 Park Ave (2)e a. BY, CITY OF SANFORD. BUILDING & FIRE PREVENTION PERMIT APPLICATION C.. Application No: 1 O ` Documented Construction Value: $ . a Job Address: f /s2k Roe ; Historic District: Yes No Parcel ID: Zoning: 3 Description of Work: Plan Review Contact Person: '.L1 t /2 =GC> t7d.r c..b Six) Title: m n rz Phone: LID 7, -719 - 3096 Fax: q6 7.3 z / E-mail:. 14 Property Owner Information - Name ®KA ?20 p8/LT) s Phone: 0/07- 2 Z I — 9f9 J Street: S', 9 re d 2_ Resident of property? : e5 City, State Zip: LA,--e YOA/2 i L `I2 Contractor Information Name C- R /c, C, L_ C Phone: -7 30 Street: % D (1 Ae' _'1 2tP eA f oD cl Fax: ` ' 7 " ag 3 <1t City, State Zip: &,I / T G1'9 n i 3 2-751 State License No.: Architect/Engineer Information Name: 2j6AJ7"Z®&, 4D l Phone: 3S 2 Zy 7 — d !D o Street: •2 q D 2 9 -ram I-s L-Je it t3c.y Fax: Z; L4 Z - 030 Z City, St, Zip: L 2 L 3 "? 1 / E-mail: Bonding Company: Mortgage Lender: Address: Address: PERMIT INFORMATION Building Permit Square Footage: Construction Type: No. of Dwelling Units: Electrical New Service - No. of AMPS: No. of Stories: Flood Zone: Plumbing ' Mechanical E (Duct layout required for new systems) YAW Hem i " _5' 0 /0'0S. &/L New Construction - No. of Fixtures: Fire Sprinkler/Alarm No. of heads: P°' if Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the' issuance .of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, ;pools, furnaces, boilers, heaters, tanks, and air conditioners,, etc. ' OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR`AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review -fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. 71 of Contractor/Agent Date Print Contractor/Agent's Name Signature of Notary -ate UTlorida m ° ••.'oDate O:uN ,• 6 0. e ssAnuepa4 Contractor/ Agent i *r N, Personally Known to Me or Produced ID Type of ID F L `, APPROVALS: ZONING: 40a'Zoll UTILITIES: IV Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/ Agent is Personally Known to Me or Produced ID Type of ID ENGINEERING: COMMENTS: WASTE WATER: BUILDING: Rev 11.08 Seminole County Property Appraiser Get Information by Parcel Number Page I of 1 PARCEL DETAIL D^viD Jo, NsoN. CFA.ASA 3.0 a 4 22 4. 0 PROPERTY 4iPPRAISER. SEMINGLE COUNTY A 4.A UJ 03041T lu -0303- X X 76-0 eel - A FL 1101 E.FIRSTST U) InSAKFoRa. FL32771-14sa W 2ND ST E2NDST 407 - 6!Zs77soa F_ eo-_1 F o--,] r ;L FRI .5 VALUE SUMMARY VALUES 2011 2010 Working Certified GENERAL Value Method Cost/Market Cost/Market Parcel Id: 25-19-30-5AG-0304-009A Number of Buildings 1 1 Owner: ROKA PROPERTIES INC Depreciated Bldg Value 259,126 265,266 Mailing Address: 856 SILVERWOOD DR Depreciated EXFT Value 0 0 Clty, State,ZIpCode: LAKE MARY FL 32746 Land Value (Market) 26,325 26,325 Property Address: 114 PARK AVE Land Value Ag 0 0 Facility Name: THE ALLEY Just/ Market Value 285,451 291,591 Tax District: S3-SANFORD-WATERFRONT REDVDST Portablity AdJ 0 0 Exemptions: Save Our Homes AdJ 0 i_0 Dor. 1802-TWO STORY OFFICE BLD Amendment I AdJ 0 0 Assessed Value (SOH) 285,451 291,591 Tax Estimator 2011 TAXABLE VALUE WORKING ESTIMATE Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 285,451 0 285,451 Amendment 1 adjustment Is not applicable to school assessment) Schools 285,451 0 285,451 City Sanford 285,451 0 285,451 SJWM( SaInt Johns Water Management) 285,451 0 285,451 County Bonds 285,4511 0! 285,4511 The taxable values and taxes are calculated using the current years working values and the prior years approved millage rates. SALES 2010 VALUE SUMMARY Deed Date Book Page Amount Vaclimp Qualified WARRANTY DEED 12/2002 04661 0630 $350,000 Improved No 2010 Tax Bill Amount: $5,857 WARRANTY DEED 01/2000 03783 1743 $68,000 Improved No 2010 Certified Taxable Value and Taxes DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS Find Sales within this DOR Code LEGAL DESCRIPTION LAND Land Assess Method Frontage Depth Land Units Unit Price Land Value PLATS: Pick... - SQUARE FEET - 0 0 5,265 5.00 $26,325 LEG S 15.73 FT OF LOT 9 + N 29.27 FT OF LOT 10 BLK 3 TR 4 TOWN OF SANFORD PB 1 PIS 68 BUILDING INFORMATION Bid Num Bid Class Year Bit Fixtures Gross SF Stories Ext Wall Bid Value Est Cost New 1 MASONRY PILAS 1901 19 7,320 2 BRICK COMMON -MASONRY $259,126 $569,508 Subsection I Sqft OPEN PORCH FINISHED/ 42 Subsection / Sqft OPEN PORCH FINISHED/ 18 Subsection I Sqft CANOPY / 450 Subsection Sqft CANOPY / 450 Permits NOTE: Assessed values shown are NOT ceriffled values and therefore are subject to change before being finalized for ad valorem tax purposes. I- ffyou recentfy purchased a homesteaded property your next year's property tax will be based on Just/Market value. http:// Www.scpafl.org/web/re—web.seminole—county_title?parcel=2519305AGO304009A&... 3/23/2011 Florida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge Summit® Fla/Com-2008, Effective: March 1, 2009 -- Form 40OB-2008 Method B: Prescriptive Compliance for Renovations, Occupancy Change, etc. PROJECT SUMMARY Short Desc: New Prj Description: Alley Bar Owner: Alley Bar Addressl: 114 Park Ave. City: Sanford Address2: State: Florida Zip: 32771 Type: Dining: Bar Lounge/Leisure Class: Renovation to existing buildi Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Conditioned Area: 2592 SF Conditioned & UnConditioned Area: 2592 SF No of Stories: 1 Area entered from Plans 2592 SF Permit No: 0 Max Tonnage 5 If different, write in: EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 2/28/2011 Page 1 of 7 d Compliance Summary 11 Component Design Criteria Result 11 RENOVATED ENVELOPE PRESCRIPTIVE LIGHTING POWER LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? 1.0 PASSES 3,110.4 PASSES PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report 2/28/2011 EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Robert Wessling Building Official: Date: Date: I certify that this building is in compliance with the Florida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (") that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: Signature is required where Florida Law requires design to be performed by registered design professionals. Project: New Prj Title: Alley Bar Type: Dining: Bar Lounge/Leisure WEA File: FL_ORLANDO_SANFORD AIRPORT.tm3) Prescriptive Envelope Compliance Item Zone Description Design Criteria Meet Req. Glass PrOZol Percent glass Max allowed .000 50.000 Yes Skylights PrOZol Percent Skylight Max allowed .000 5.000 Yes Meets Shell Envelope Requirements -- PASSES EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 2/28/2011 Page 3 of 7 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP W/Unit) or No. of Units (W) (W) Sgft or ft) None Project: New Prj Title: Alley Bar Type: Dining: Bar Lounge/Leisure WEA File: FL_ORLANDO_SANFORD AIRPORT.tm3) Lighting Power Compliance Space Ashrae Description Area Height No. of Design Effective Allowance ID (sq.ft) (ft) Spaces (W) (W) (W) PrOZo1Sp1 9 Food Service - Bar/Lounge 2,592 9.0 1 1 1 3,110 Design 1 (W) PASSES Effective: 1 (W) Allowance: 3110.4 (W) Passing requires Design to be at most 100% of Criteria Project: New Prj Title: Alley Bar Type: Dining: Bar Lounge/Leisure WEA File: FL ORLANDO SANFORD AIRPORT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance Pr0Zo1Spl 9 Food Service - Bar/Lounge 2,592 2 2 PASSES PASSES EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 2/28/2011 Page 4 of 7 Project: New Prj Title: Alley Bar Type: Dining: Bar Lounge/Leisure WEA File: FL_ORLANDO_SANFORD AIRPORT.tm3) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Heating System Air Handling System -Supply Air Conditioners Air Cooled 13.00 12.23 8.00 PASSES Split System < 65000 Btu/h Cooling Capacity Electric Furnace 1.00 1.00 PASSES Air Handler (Supply) - 0.80 0.90 PASSES Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance None EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 2/28/2011 Page 5 of 7 Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] F] .SF.F] None EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 2/28/2011 Page 6 of 7 Project: New Prj Title: Alley Bar Type: Dining: Bar Lounge/Leisure WEA File: FL ORLANDO_SANFORD_AIRPORT.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 13-101 Input Report Print -Out from EnergyGauge FlaCom attached Operations Manual 13-102.1, Operations manual provided to owner 13-410,13-413 Windows & Doors 13-406.AB.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfin/ftz; all other products: 0.4 cfin/ftz Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls System 13-407 HVAC Load sizing has been performed Reheat 13-407.B Electric resistance reheat prohibited HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.3.2.1A-D; Heating Tables 13-407.AB.3.2.1B, 13-407.AB.3.2.1D, 13-408.AB.3.2.1E, 13-408.AB.3.2F HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating and cooling in each zone; combined HAC deadband of at least 5°F exceptions) Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) exhaust systems and 2) systems with design outside air intake or exhaust capacity <_300 cfm ADS 13-410 Duct sizing and Design have been performed HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Sec. 13-410 Air Distribution Systems Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in construction documents Piping Insulation 13-41 LAB In accordance with Table 13-41 LAB.2 Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. Heat trap required Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); Readily accessible on/off switch Hot Water Pipe 13-41 LAB.3 Table 13-41 LAB.2 for circulating systems, first 8 feet of outlet El Insulation pipe from storage tank and between inlet pipe and heat trap Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public lavatory fixture how water flow 0.5 gpm max; if self -closing valve 0.25 gallon recirculating, 0.5 gallon non recirculating Motors 13-414 Motor efficiency criteria have been met Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluuorescent lamps>30W EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 2/28/2011 Page 7 of 7 Print Page 1 of 1 From: Fabian Garcia (fgarcial90@aol.com) To: ldonaldsonl 122@att.net; Date: Wed, March 9, 2011 11:11:03 AM Cc: Subject: Fwd: Air Conditioning Estimate Original Message — From: fgarcia190 <fgarcia190@aol.com> To: robh <robh@insuranceriskservices.com> Sent: Fri, Sep 24, 2010 6:55 pm Subject: Air Conditioning Estimate Hello Rob, Just wanted to once again apologize for being so late getting this to you. This quote will include the following; Goodman Air Handler Model# Aruf486016b Goodman Straight Cool Condenser Model# Gsx130601 b Ductwork to include 6 supply drops and 1 return drop. Each bathroom will receive a drop, and the pool table area will have 4 supply drops and 1 return drop. As mentioned in our conversation earlier electrical work will not be included. Our equipment requires 220v to both inside and outside units. Total price for this 4 ton system and ductwork will be $5950.00. If you decide to do this I anticipate the work taking about 2 days. Thanks once again for your time and also am very sorry I forgot about you. Fabian Garcia B&L A/C Service LLC Managing Member Sent from my HTC on the Now Network from Sprint! http://us.mg203.mail.yahoo.com/dc/launch?.partner=sbc&.gx=1&.rand=bgdOgfn987s60 3/9/2011 Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance Btu/h.sf.F] Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] [ft] Btu/h.ft.F] lb/cf] Btu/lb.F] 178 Matl 17 8 CARPET WIRU13BER PAD Yes 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 Layer Material Material Thickness Framing No. ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 2/28/2011 EnergyGauge Summit® v3.22 Project Name: New Prj Project Title: Alley Bar Address: 114 Park Ave. State: Florida Zip: 32771 Owner: Alley Bar EnergyGauge Summit® v3.22 INPUT DATA REPORT Project Information Orientation: East Building Type: Dining: Bar Lounge/Leisure Building Classification: Renovation to existing building No.of Stories: 1 GrossArea: 2592 SF Zones No Acronym Description Type Area sfl Multiplier Total Area sfl 1 PrOZo I Zone 1 CONDITIONED 2592.0 1 2592.0 Spaces No Acronym Description Type Depth IN Width Height Multi IN [ftl plier Total Area sf] Total Volume cf] 2/28/2011 EnergyGauge Summit® Q.22 1 In Zone: PrOZol 1 Pr0Zo1Sp1 Zo0Sp1 Food Service - Bar/Lounge 96.00 27.00 9.00 1 2592.0 23328.0 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Recessed Fluorescent - General Lighting 1 1 1 Manual On/Off 2 No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] Btu/hr. sf. F] Capacity Ib/cf] [h.sf.FBtu] Btu/sf.F] In Zone: Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area Btu/hr sf F] IN [ft] plier sf] In Zone: In Wall: El Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: In Wall: 2/28/2011 EnergyGauge Summit® v3.22 Roofs No Description Type Width H (Effec) Multi ft] IN plier Area sf] Tilt Cond. Heat Cap Dens. R-Value deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: Skylights No Description Type U SHGC Vis.Trans Btu/hr sf F] W H (Effec) Multiplier ft] [ft] Area Total Area Sf] [Sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi ft] [ft] plier Area sf] Cond. Heat Cap. Dens. Btu/hr. sf. F] [Btu/sf. F] [Ib/cf] R-Value h.sf.F/Btu] In Zone: PrOZol 1 Pr0Zo1F11 1 ft. soil, concrete floor, carpet and rubber pad 27.00 96.00 1 2592.0 0.2681 34.00 113.33 3.73 Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 2/28/2011 EnergyGauge Summit® v3.22 I Cooling System 2 Heating System 3 Air Handling System -Supply 60000.00 34100.00 1500.00 13.00 8.00 1.00 0.80 Plant Equipment Category Size Inst.No Eff. IPLV UJI Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf/ft/No] Control Type Wattage W] El Piping No Type Operating Insulation Temperature Conductivity F] [ Btu-in/h.sf.F] Nomonal pipe Diameter in] Insulation Is Runout? Thickness in] El 2/28/2011 EnergyGauge Summit® v3.22 t Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance Btu/h.sf.F] Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btu] [11] Btu/h.ft.F] lb/cf] Btu/lb.F] 179 at es 1.2300 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 Layer Material Material Thickness Framing No. ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 2/28/2011 EnergyGauge Summit® v3.22 r, J Project Name: New Prj Project Title: Alley Bar Address: 114 Park Ave. State: Florida Zip: 32771 Owner: Alley Bar EnergyGauge Summit® v3.22 INPUT DATA REPORT Proiect Information Orientation: East Building Type: Dining: Bar Lounge/Leisure Building Classification: Renovation to existing building No.of Stories: 1 GrossArea: 2592 SF Zones No Acronym Description Type Area s11 Multiplier Total Area lsfl 1 PrOZoI Zone I CONDITIONED 2592.0 1 2592.0 Spaces No Acronym Description Type Depth lftl Width Height Multi IN lftl plier Total Area lsfl Total Volume lell 2/28/2011 EnergyGauge Summit® v3.22 1 In Zone: PrOZol 1 PrOZo1Sp1 Zo0Sp1 Food Service - Bar/Lounge 96.00 27.00 9.00 1 2592.0 1, 23328.0 Lighting i' No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Recessed Fluorescent General Lighting 1 1 1 Manual On/Off 2 No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value ft] [ft] plier [sf] Btu/hr. sf. F] Capacity lb/cf] [h.sf.F/Btu] Btu/sf.F] In Zone: Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area Btu/hr sf F] IN [ft] plier sf] In Zone: In Wall: Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value ft] [ft] plier sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: In Wall: 2/28/2011 EnergyGauge Summit® v3.22 Roofs No Description Type Width H (Effec) Multi ft] [ft] plier Area sf] Tilt Cond. Heat Cap Dens. R-Value deg] [Btu/hr. SE F] [Btu/sf. Fl [lb/cf] [h.sf.FBtu] In Zone: Skylights No Description Type U SHGC Vis.Trans Btu/hr sf F] W H (Effec) Multiplier ft] [ft] Area Total Area Sf] [Sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi ft] [ft] plier Area sf] Cond. Heat Cap. Dens. Btu/hr. sf. F] [Btu/sf. F] [Ib/cq R-Value h.sf.FBtu] In Zone: PrOZol 1 Pr0Zo1F11 1 ft. soil, concrete floor, carpet and rubber pad 27.00 96.00 1 2592.0 0.2681 34.00 113.33 3.73 Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 2/28/2011 EnergyGauge Summit® v3.22 I Cooling System 2 Heating System 3 Air Handling System -Supply 60000.00 34100.00 1500.00 13.00 8.00 1.00 0.80 El Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit3Cap.Unit UP Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf/ft/No] Control Type Wattage W] El Piping No Type Operating Insulation Temperature Conductivity F] [ Btu-in/h.sf.F] Nomonal pipe Diameter in] Insulation Is Runout? Thickness in] El 2/28/2011 EnergyGauge Summit® v3.22 Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance Btu/h.sf.F] Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.F/Btu] [11] Btu/h.ft.F] lb/cf] Btu/lb.F] 178 at es 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 Layer Material Material Thickness Framing No. ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 2/28/2011 EnergyGauge Summit® v3.22 System/Area Pleating and Cooling Load Summary Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB System -Wide Max. Cool Load Time: September at 4:00 PM Total Sensible Total Total Summer Winter Area Maximum Qty Area Cooling Cooling Heating CFM CFM Cooling Load Time Zone Name: Rear of building Rear 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 September at 4:00 PM Room Totals by Zone: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Room Totals by System: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 AddYl Coil Totals: 12,249.2 26,820.5 20,470.9 Total Loads by System: 27,553.8 49,815.2 23,107.8 Total Tonnage: 4.2 Room Grand Totals: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Addt9 Coil Grand Totals: 12,249.2 26,820.5 20,470.9 Grand Totals: 27,553.8 49,815.2 23,107.8 Total Tonnage: 4.2 P, System/Area Heating and Cooling Load' Summary Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB System -Wide Max. Cool Load Time: August at 10:00 AM Total Sensible Total Total Summer Winter Area Maximum city Area Cooling Cooling Heating CFM CFM Cooling Load Time Zone Name: Bar area Main bar 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 August at 10:00 AM Room Totals by Zone: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Room Totals by System: 1 1.365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Addfl Coil Totals: 6,962.7 14,278.8 10,917.8 Total Loads by System: 41,933.5 54,614.4 18,871.1 Total Tonnage: 4.6 Room Grand Totals: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Addfl Coil Grand Totals: 6,962.7 14,278.8 10,917.8 Grand Totals: 41,933.5 54,614.4 18,871.1 Total Tonnage: 4.6 Breakdown of All Load Components Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB System SgFt: 1,200.0 Max. Cool Load Time: September at 4:00 PM Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wall Load 243.0 SgFt 1,006.3 1,006.3 2.0% 2,207.6 Window Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Door Load 20.0 SgFt 138.5 138.5 0.3% 303.8 People Load 60.0 People 10,927.2 6,30O.0 17,227.2 34.6% 0.0 Lighting Load 720.0 Wafts 1,486.0 1,486.0 3.0% 0.0 Electrical Load 600.0 Wafts 1,017.9 1,023.9 2,041.8 4.1% 0.0 Partition Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 728.8 366.2 1.095.0 2.2% 125.6 Subtotal 15,304.6 7,690.1 22,994.7 46.2% 2,636.9 Cool Ventilation Load 600.0 CFM 11,786.3 14,571.2 26,357.5 52.9% Heat Ventilation Load 600.0 CFM 20,470.9 Plenum Load 0.0 0.0 0.0% Fan Heat Load 463.0 463.0 0.9% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 27,553.8 22,261.3 49,815.2 100.0% 23,107.8 e. Breakdown of All Load Components Page 2 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: Existing Outside Temperature: 94.OF DB / 76.017 WB System SgFt: 1,365.0 Max. Cool Load Time: August at 10:00 AM Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wall Load 243.0 SgFt 850.3 850.3 1.6% 1,039.5 Window Load 138.0 SgFt 19,962.0 19,962.0 36.6% 3,643.2 Door Load 0.0 SgFt 0.0 0.0 0.0% 0.0 People Load 40.0 People 8,734.3 4,200.0 12,934.3 23.7% 0.0 Lighting Load 819.0 Watts 2,327.0 2,327.0 4.3% 0.0 Electrical Load 682.5 Watts 1,106.5 1,164.7 2,271.1 4.2% 0.0 , Partition Load 1,580.0 SgFt 1,990.8 1,990.8 3.6% 3,270.6 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 0.0 0.0 0.0 0.0% 0.0 Subtotal 34,970.8 5,364.7 40,335.5 73.9% 7,953.3 Cool Ventilation Load 320.0 CFM 5,955.2 7,316.2 13,271.3 24.3% Heat Ventilation Load 320.0 CFM 10,917.8 Plenum Load 0.0 0.0 0.0% Fan Heat Load 1,007.5 1,007.5 1.8% Dud Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 41,933.5 12,680.9 54,614.4 100.0% 18,871.1 MA Breakdown of All Load Components Page 3 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: All Systems Outside Temperature: 94.OF DB / 76.OF WB Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0°% 0.0 Wall Load 486.0 SgFt 1,856.6 1,856.6 1.8% 3,247.1 Window Load 138.0 SgFt 19,962.0 19,962.0 19.1% 3,643.2 Door Load, 20.0 SgFt 138.5 138.5 0.1 °% 303.8 People Load 100.0 People 19,661.5 10,500.0 30,161.5 28.9% 0.0 Lighting Load 1,539.0 Watts 3,813.0 3,813.0 3.7% 0.0 Electrical Load 1,282.5 Watts 2,124.3 2,188.6 4,312.9 4.1% 0.0 Partition Load 1,580.0 SgFt 1,990.8 1,990.8 1.9% 3,270.6 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0°% 0.0 Safety Factors 728.8 366.2 1,095.0 1.0% 125.6 Subtotal 50,275.4 13,054.8 63,330.2 60.6°% 10,590.2 Cool Ventilation Load 920.0 CFM 17,741.4 21,887.4 39,628.9 37.9% Heat Ventilation Load 920.0 CFM 31,388.7 Plenum Load 0.0 0.0 0.0°% Fan Heat Load 1.470.5 1,470.5 1.4°% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 69,487.3 34,942.2 104,429.5 100.0% 41,978.9 1` System/Area Heating and Cooling Load Summary Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB System -Wide Max. Cool Load Time: September at 4:00 PM Total Sensible Total Total Summer Winter Area Maximum sty Area Cooling Cooling Heating CFM CFM Cooling Load Time Zone Name: Rear of building Rear 1 1,200.0 15,304.6 22,994.7 2,636.9, 740.2 600.0 September at 4:00 PM Room Totals by Zone: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Room Totals by System: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Addt'I Coil Totals: 12,249.2 26,820.5 20,470.9 Total Loads by System: 27.553.8 49,815.2 23,107.8 Total Tonnage: 4.2 Room Grand Totals: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Addt9 Coil Grand Totals: 12,249.2 26,820.5 20,470.9 Grand Totals: 27,553.8 49,815.2 23,107.8 Total Tonnage: 4.2 System/Area Heating and Cooling Load Summary Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: Existing Outside Temperature: 94.017 DB / 76.OF WB System -Wide Max. Cool Load Time: August at 10:00 AM Total Sensible Total Total Summer Winter Area Maximum Qty Area Cooling Cooling Heating CFM CFM Cooling Load Time Zone Name: Bar area Main bar 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 August at 10:00 AM Room Totals by Zone: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Room Totals by System: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Addt9 Coil Totals: 6,962.7 14,278.8 10,917.8 Total Loads by System: 41,933.5 54,614.4 18,871.1 Total Tonnage: 4.6 Room Grand Totals: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Addfl Coil Grand Totals: 6,962.7 14,278.8 10,917.8 Grand Totals: 41,933.5 54,614.4 18,871.1 Total Tonnage: 4.6 Breakdown of AII'Load Components Page 1 2/21/2011 Lindemann, Benlzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: A/C-1 Outside Temperature: 94.OF DB / 76.OF WB System SgFt: 1,200.0 Max. Cool Load Time: September at 4:00 PM Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wall Load 243.0 SgFt 1,006.3 1,006.3 2.0% 2,207.6 Window Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Door Load 20.0 SgFt 138.5 138.5 0.3% 303.8 People Load 60.0 People 10,927.2 6,300.0 17,227.2 34.6% 0.0 Lighting Load 720.0 Watts 1,486.0 1,486.0 3.0% 0.0 Electrical Load 600.0 Watts 1,017.9 1,023.9 2,041.8 4.1% 0.0 Partition Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 728.8 366.2 1,095.0 2.2% 125.6 Subtotal 15,304.6 7,690.1 22,994.7 46.2% 2,636.9 Cool Ventilation Load 600.0 CFM 11,786.3 14,571.2 26,357.5 52.9%° Heat Ventilation Load 600.0 CFM 20,470.9 Plenum Load 0.0 0.0 0.0% Fan Heat Load 463.0 463.0 0.9% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 27,553.8 22,261.3 49,815.2 100.0% 23,107.8 Breakdown of All Load Components Page 2 2/2112011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB System SgFt: 1,365.0 Max. Cool Load Time: August at 10:00 AM Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgF.t 0.0 0.0 0.0% 0.0 Wall Load 243.0 SgFt 850.3 850.3 1.6% 1,039.5 Window Load 138.0 SgFt 19,962.0 19,962.0 36.6% 3,643.2 Door Load 0.0 SgFt 0.0 0.0 0.0% 0.0 People Load 40.0 People 8,734.3 4,200.0 12,934.3 23.7% 0.0 Lighting Load 819.0 Watts 2,327.0 2,327.0 4.3% 0.0 Electrical Load 682.5 Watts 1,106.5 1,164.7 2,271.1 4.2% 0.0 Partition Load 1,680.0 SgFt 1,990.8 1;990.8 3.6% 3,270.6 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 0.0 0.0 0.0 0.0% 0.0 Subtotal 34,970.8 5,364.7 40,335.5 73.9% 7,953.3 Cool Ventilation Load 320.0 CFM 5,955.2 7,316.2 13,271.3 24.3% Heat Ventilation Load 320.0 CFM 10,917.8 Plenum Load 0.0 0.0 0.0% Fan Heat Load 1,007.5 1,007.5 1.8% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 41,933.5 12,680.9 54,614.4 100.0% 18,871.1 Breakdown of All Load'Components Page 3 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida.34712 Building Name: Alley Bar Location: Orlando, Florida System Name: All Systems Outside Temperature: 94.OF DB / 76.OF WB Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wall Load 486.0 SgFf 1,856.6 1,856.6 1.8% 3,247.1 Window Load 138.0 SgFt 19,962.0 19,962.0 19.1% 3,643.2 Door Load 20.6 SgFt 138.5 138.5 0.1% 303.8 People Load 100.0 People 19,661.5 10,500.0 30,161.5 28.9% 0.0 Lighting Load 1,539.0 Watts 3,813.0 3,813.0 3.7% 0.0 Electrical Load 1,282.5 Watts 2,124.3 2,188.6 4.312.9 4.1% 0.0 Partition Load 1,580.0 SgFt 1,990.8 1,990.8 1.9% 3,270.6 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 728.8 366.2 1,095.0 1.0% 125.6 Subtotal 50,275.4 13,054.8 63,330.2 60.6% 10,590.2 Cool Ventilation Load 920.0 CFM 17,741.4 21,887.4 39,628.9 37.9% Heat Ventilation Load 920.0 CFM 31,388.7 Plenum Load 0.0 0.0 0.0% Fan Heat Load 1,470.5 1,470.5 1.4% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 69,487.3 34,942.2 104,429.5 100.0% 41,978.9 3 System/Area Heating and Cooling Load Summary Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: A/C-1 Outside Temperature: 94.OF DB / 76.017 WB System -Wide Max. Cool Load Time: September at 4:00 PM Total Sensible Total Total Summer Winter Area Maximum qty Area Cooling Cooling Heating CFM CFM Cooling Load Time Zone Name: Rear of building Rear 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 September at 4:00 PM Room Totals by Zone: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Room Totals by System: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 AddYl Coil Totals: 12,249.2 26,820.5 20,470.9 Total Loads by System: 27,553.8 49,815.2 23,107.8 Total Tonnage: 4.2 Room Grand Totals: 1 1,200.0 15,304.6 22,994.7 2,636.9 740.2 600.0 Addrl Coil Grand Totals: 12,249.2 26,820.5 20,470.9 Grand Totals: 27,553.8 49,815.2 23,107.8 Total Tonnage: 4.2 System/Area Heating and Cooling Load Summary Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB System -Wide Max. Cool Load Time: August at 10:00 AM Total Sensible Total Total Summer Winter Area Maximum City Area Cooling Cooling Heating CFM CFM Cooling Load Time Zone Name: Bar area Main bar 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 August at 10:00 AM Room Totals by Zone: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Room Totals by System: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Addt9 Coil Totals: 6,962.7 14,278.8 10,917.8 Total Loads by System: 41,933.5 54,614.4 18,871.1 Total Tonnage: 4.6 Room Grand Totals: 1 1,365.0 34,970.8 40,335.5 7,953.3 1,610.7 320.0 Addt9 Coil Grand Totals: 6,962.7 14,278.8 10,917.8 Grand Totals: 41,933.5 54,614.4 18,871.1 Total Tonnage: 4.6 Breakdown of All Load Components Page 1 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: A/C-1 Outside Temperature: 94.OF DB / 76.017 WB System SgFt: 1,200.0 Max. Cool Load Time: September at 4:00 PM Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wall Load 243.0 SgFt 1,006.3 1,006.3 2.0% 2,207.6 Window Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Door Load 20.0 SgFt 138.5 138.5 0.3% 303.8 People Load 60.0 People 10,927.2 6,300.0 17,227.2 34.6% 0.0 Lighting Load 720.0 Watts 1,486.0 1,486.0 3.0% 0.0 Electrical Load 600.0 Wafts 1,017.9 1,023.9 2,041.8 4.1% 0.0 Partition Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 728.8 366.2 1,095.0 2.2% 125.6 Subtotal 15,304.6 7,690.1 22,994.7 46.2% 2,636.9 Cool Ventilation Load 600.0 CFM 11,786.3 14,571.2 26,357.5 52.9% Heat Ventilation Load 600.0 CFM 20,470.9 Plenum Load 0.0 0.0 0.0% Fan Heat Load 463.0 463.0 0.9% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 27,553.8 22,261.3 49,815.2 100.0% 23,107.8 Breakdown of All Load Components Page 2 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: Existing Outside Temperature: 94.OF DB / 76.OF WB System SgFt: 1,365.0 Max. Cool Load Time: August at 10:00 AM Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wall Load 243.0 SgFt 850.3 850.3 1.6% 1,039.5 Window Load 138.0 SgFt 19.962.0 19,962.0 36.6% 3,643.2 Door Load 0.0 SgFt 0.0 0.0 0.0% 0.0 People Load 40.0 People 8,734.3 4,200.0 12,934.3 23.7% 0.0 Lighting Load 819.0 Watts 2,327.0 2,327.0 4.3% 0.0 Electrical Load 682.5 Watts 1,106.5 1,164.7 2,271.1 4.2% 0.0 Partition Load 1,580.0 SgFt 1,990.8 1,990.8 3.6% 3,270.6 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 0.0 0.0 0.0 0.0% 0.0 Subtotal 34.970.8 5,364.7 40,335.5 73.9% 7,953.3 Cool Ventilation Load 320.0 CFM 5,955.2 7,316.2 13,271.3 24.3% Heat Ventilation Load 320.0 CFM 10,917.8 Plenum Load 0.0 0.0 0.0% Fan Heat Load 1,007.5 1,007.5 1.8% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 41,933.5 12,680.9 54,614.4 100.0% 18,871.1 Breakdown of All Load Components Page 3 2/21/2011 Lindemann, Bentzon, Bojack Engineering 290 Citrus Tower Blvd. Clermont, Florida 34712 Building Name: Alley Bar Location: Orlando, Florida System Name: All Systems Outside Temperature: 94.OF DB / 76.OF WB Description Units Sensible Latent Total of Total Heating Roofing Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Wail Load 486.0 SgFt 1,856.6 1,856.6 1.8% 3,247.1 Window Load 138.0 SgFt 19,962.0 19,962.0 19.1% 3,643.2 Door Load 20.0 SgFt 138.5 138.5 0.1% 303.8 People Load 100.0 People 19,661.5 10,500.0 30,161.5 28.9% 0.0 Lighting Load 1,539.0 Watts 3,813.0 3,813.0 3.7% 0.0 Electrical Load 1,282.5 Watts 2,124.3 2,188.6 4.312.9 4.1% 0.0 Partition Load 1,680.0 SgFt 1,990.8 1,990.8 1.9% 3,270.6 Floor Slab Load 0.0 SgFt 0.0 0.0 0.0% 0.0 Miscellaneous Load 0.0 0.0 0.0 0.0% 0.0 Infiltration Load 0.0 CFM 0.0 0.0 0.0 0.0% 0.0 Safety Factors 728.8 366.2 1,095.0 1.0% 125.6 Subtotal 50,275.4 13,054.8 63,330.2 60.6% 10,590.2 Cool Ventilation Load 920.0 CFM 17,741.4 21,887.4 39,628.9 37.9% Heat Ventilation Load 920.0 CFM 31,388.7 Plenum Load 0.0 0.0 0.0% Fan Heat Load 1,470.5 1,470.5 1.4% Duct Heat Load 0.0 0.0 0.0% 0.0 Reheat Load 0.0 0.0 0.0% Coil Load 0.0 0.0 0.0% Total Loads 69,487.3 34,942.2 104,429.5 100.0% 41,978.9