Loading...
HomeMy WebLinkAbout100 Belveders Way (2), CITY OF SANFORD r, BUILDING & FIRE PREVENTION 7 2015 PERMIT APPLICATION Application No: Documented Construction Value: S 7,160 i Job Address: 13Historic District: Yes ❑ No ❑ Parcel ID: 07-20-31-513-OA00-0000 Residential ❑ Commercial ❑X Type of Work: New ❑ Addition El Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ 1 0 Description of Work: Extend the le of the existing brick privacy wall Plan Review Contact Person: Steve Dinter 9 Title: Project Manager ° Phone: (407) 322-754 Ex: 102 Fax: (407) 322-8194 Email: steve@morton-construction.net Property Owner Information Name Treviso Community Association, Inc. Phone: (407)977-0031 Ext: 303 Street: 511 E. S.R. 434, Suite 3001 Resident of property? : City, State Zip: Winter Springs, FL 32708 1. Contractor Information Name Morton Construction Company Phone: (407) 322-0754 Ext: 102 Street: 3835 Richmond Ave. Fax: (407) 322-8194 City, State Zip: Sanford, FL 32773 State License No.: CBC 058131 Architect/Engineer Information Name: Wayne Block, Lildon Engineering Company Street: 920 Sunset Shores Drive Phone: (352) 394-2590 Fax: (352) 394-2590 City, St, Zip: Minneola FL 34715 E-mail: wablock@aol.com Bonding Company: None Mortgage Lender: None Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that,no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code 4% Revised: lune 30, 2015 Permit Application eh In � eI 6rz4z pr; N,&q'Gr EXISTING PRIVACY WALL EXISTING / CRAPE MYRTLE PROPOSED PRIVACY WALL EXTENSION OAK TREE TO PROTECT BE REMOVED REMAINING OAK 'ROX. 6" DBH ,TREES SOUTH PROPERTY LINE TREE REMOVAL PLAN 111=102-011 (4) RODS IN COLUMN, (1) AT EACH CORNER EXTEND HORIZONTAL JOINT REINFORCING 12" INTO NEW COLUMN 4 FEET START HORIZONTAL JOINT REINFORCING OVER 5th COURSE 32" THREADED ROD AT 36" 0. C. MAX. PROPOSED PRIVACY (TYP-) \ > WALL EXTENSION M w P, a P4 F ul HORIZONTAL JOINT REINFORCING EVERY 3 COURSES (12" OC) FINISHED GRADE - -------------------------------------------------------------------------------- E z 30x30x10 FOOTING PAD w/ 3- #5 BARS EACH WAY 10x20 CONTINUOUS FOOTING w w/ 3- #5 BARS CONT. ELEVATION 0 1/2"=V-0„ SOUTH PROPERTY LINE PLAN VIEW 1/4"=1'-0" DRILL 3/16" DIAx 4" HOLES & SET #9 WIRE (HORZ. JOINT REINFORCMENT) WITH EPDXY INTO EXISTING COLUMN EXISTING PRIVACY WALL DRILL 3/4" DIA x 4" HOLES & SET #5 BARS WITH EPDXY INTO EXISTING FOOTING (4) RODS IN COLUMN, (1) AT EACH CORNER T-4" (MAX) FINISH GRAS 6" MIN. 30x30x10 FOOTING PAD w/ 3- #5 BARS EACH WAY COLUMN SECTION 1 "=1'-0" SANFOM frifaDePMTMENT SSE PLANS ARE FWV*MW AND COMMTIONALJLY ACCEPTED FOR PERMIT AN ISSUED PERMIT SHALL BE DEEMEfD PERMISSION TO PRIED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROMSMS OF IM TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE FM PREVENTION DIVISION FROM THEREAFTER REQUIRING A C4RRI �i"i ERMORS ON THE F'U�� OR OTHER VKXnCW0F 1W CODE Plans C lv . By Fire REVIEWED BY: MATT MIINNN-E SANFORD FIRE DEPT DATE: TRIANGLE BRICK CAPE COD MODULAR (2 1/4" x 3 9/16" x 7 5/8") TRIANGLE BRICK CAPE COD UTILITY (3 9/16" x 3 9/16" x 11 9/16") 7-0" (MAX) 9 GA. WIRE HORIZONTAL JOINT REINFORCING OVER 5th COURSE AND EVERY 3 COURSES ABOVE (12" OC) CONCRETE NOTES 1. POURED GROUT & FOOTINGS: 2500 psi (MIN.) 2. MASONRY UNITS: fm = 2500 psi MORTAR TYPE 'S' OR'M', 1800 psi 3. REINFORCEMENT: #9 x 3" GALV STL WIRE HORIZONTAL BRICK (GLASS BLOCK) REINFORCEMENT. #5 Bar Grade 40 IN FOOTINGS. ENGINEERING NOTES: ENGINEERING MEETS OR EXCEEDS 2014 FLORIDA BUILDING CODE, 5TH EDITION, AND ASCE 7-10, 130 mph BASIC WIND SPEED (Veit). RISK CATEGORY I, Vasd = 101 mph. - EXPOSURE C. DESIGN PRESSURE: ± 20.6 psf Y2" NUT AND WASHER iz COUPLING NUT }a" COUPLING NUT Y2" THREADED ROD AT 36" 0. C. MAX (TYP.) FINISH GRADE " COUPLING NUT 6" MIN. COVER" ANCHOR BOLT AT 36" 0. C. MAX (TYP.) * NOTE: CAST IN PLACE ANCHOR BOLT MAY BE • • • SUBSTUTED WITH W 10 x 20 3,000 PSI THREADED ROD EPDXIED CONCRETE FOOTING INTO FOOTING WITH WITH (3)-#5 BARS SIMPSON SET -XP (GRADE 40) EMBEDED 4" DEEP. WALL SECTION ^ RCE PERMI -1