HomeMy WebLinkAbout410 Hansom PkwyIRIEC WEE
CITY OF SANFORD
JUL 2 8 2015 BUILDING & FIRE PREVENTION
PERMIT APPLICATION
i3Y: ----- --
Application No: 15 -d Vv
Documented Construction Value: $ k
fo
C>00
Job Address: `1" RCcY1 ,nn aY1<<,. 1 . Ar V Historic District: Yes No
Parcel ID: Residential'o Commercial
Type of Work: New Addition Alteration El Repair E, Demo Change of Use Move
Description of Work:
1 /\
Plan Review Contact Person: CO'CL44V Title:
Phone: - 3 3 -Fax:' Email: Q` -7
Property Owner Information ''
II
Name rJ M i I Phone: 4o -i- 22 i^ t b s
Street: 10 Resident of property?
L-7City, State Zip: lr- I -73
Name
Street:
City, State Zip:
Contractor Information
Phone:
Fax:
State License No.:
Architect/Engineer Information
Name: '" T, S C—inszln4 Phone:
Street: 5k. lJ . c=,2, 4M Fax:
City, St, Zip: _ ` Vo_n,orlvo ncC TL 3 V E-mail:
Bonding Company: Mortgage Lender:
Address: Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5th Edition (2014) Florida Building Code
Revised: June 30, 2015 Permit Application
N
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies. I
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all -work will
be done in compliance with all applicable laws regulating construction and zoning.
ggn—,ture o e gent Date
Print Owner/Agent's Name
Signature of Notary- S Date
i n, .. Py DEBBIE BLANTON
MY COMMISSION # FF 178648
EXPIRES: February 25, 2019RfShyBondedrhnrNotaryPubrrcUnderwriters
Owner/Agent is Personally Known to Me or
Produced ID Type of IDt— eyo
Signature of Contractor/Agent Date
Print Contractor/Agent's Name
Signature of Notary -State of Florida Date
Contractor/Agent is Personally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing[] Gas E] Roof
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes No
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
of Heads
UTILITIES:
FIRE:
Flood Zone:
of Stories:
Plumbing - # of Fixtures
Fire Alarm Permit: Yes No
WASTE WATER:
BUILDING: 43:_ /S
Revised: June 30, 2015 Permit Application
OWNER BUILDER STATEMENT/AFFIDAVIT
Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford,
Seminole County, Winter Springs
Florida Statutes are quoted here in part for your information to indicate the authority, for exemptions for
homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities.
OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT
BY SIGNING THIS STATEMENT, I ATTEST THAT: (Initial to the left of each statement)
Rev. 9.14.2009
I understand that state law requires construction to be done by a licensed contractor and have applied for
an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of
the property listed, may act as my own contractor with certain restrictions even though I do not have a
V license.
I understand that building permits are not required to be signed by a property owner unless he or she is
responsible for the construction and is not hiring a licensed contractor to assume responsibility.'
I understand that, as an owner -builder, I am the responsible party of record on a permit. I understand that I
may protect myself from potential financial risk by hiring a licensed contractor and having the-permit.filed
in his or her name instead of my own name. I also understand that a contractor is required by law to be
V licensed in Florida and to list his or her license numbers on all permit and contracts.
I understand that I may build or improve a one -family or two-family residence or a farm outbuilding. I
may also build or improve a commercial building if the costs do not exceed $75,000. The building or
residence must be for my own use or occupancy. It may not be built or substantially improved for sale or
lease. If a building or residence that I have built or substantially improved myself is sold or leased within
in 1 year after the construction is complete, the law will presume'thaf `I built or substantially unproved it
for sale or lease, which violates this exemption.
t
I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction.
I understand that I may not hire an unlicensed individual person to act as my contractor or to supervise
persons working on my building or residence. It is my responsibility to ensure that the persons whom I
employ have the licenses required bylaw and by city ordinance.
I understand that it is a frequent practice of unlicensed persons to have the property owner obtain an
owner -builder permit that erroneously implies that the property owner is providing his or her own labor
and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any
V/ injuries sustained by an unlicensed person or his or her employees while working on my property. My
homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -
builder and am aware of the limits of my insurance coverage for injuries to workers on my property.
I understand that I may not delegate the responsibility for supervising work to a licensed contractor who is
not licensed to perform the work being done. Any person working on my building who Is not licensed
must work under my direct supervision and must be employed by me, which means that I must
comply with laws requiring the withholding of federal income tax and social security contributions
under the Federal Insurance Contributions Act (FICA) and must provide workers' compensation
for the employee. I understand that my failure to follow these laws may subject me to serious financial
risk.
Rev. 9.14.2009
Property Address:_ » 4c.-NSom _Qy'1-tof/ r& 3271-5
I, o MQJ' V C oa , do hereby state that I am qualified
and capable of performing the requested construction involved with the permit application filed and agree to the
conditions specified above.
Signature of Owner -Builder
Form of Identification
Must be Photo ID)
Date
A violation of this exemption is a misdemeanor of the first degree punishable by a term of imprisonment
not exceeding 1 year and a $1,000.00 fine in addition to any civil penalties. In addition, the local
permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy
for unlicensed activity against the owner and any person performing work that requires licensure under
the permit issued.
Rev. 9.14.2009
I agree that, as the party legally and financially responsible for this proposed construction activity, I will
abide by all applicable laws and requirements that govern owner -builders aswell as employers. I also
understand that the construction must comply with all applicable laws, ordinances, building codes, and
zoning regulations.
I am of aware of construction practices and I have access fo the Florida Building Codes.
I understand that I may obtain more information regarding my obligations as an employer from the Internal
Revenue Service, the United States Small Business Administration, the Florida Department of Financial
j Services, and the Florida Department of Revenue. I also understand that I may contact the Floridaj/ Construction Industry Licensing Board at 1-850-487-1395 or at www.myflorida.conVdbpr/pro/Cilb/ for
more information about licensed contractors.
I am aware of, and consent to, an owner -builder building permit applied for in my name and understand
that I am the party legally and financially responsible for the proposed construction activity at the address
listed below.
I agree to notify the building department immediately of any additions, deletions, or changes to any of the
information that I have provided on this disclosure or in the permit application package.
Licensed contractors are regulated by laws designed to protect the public. If you contract with a person
who does not have a license, the Construction Industry Licensing Board, the Department of Business and
Professional Regulation and the building department may be unable to assist you with any financial loss
that you sustain as a result of a complaint. Your only remedy against an unlicensed contractor may be in
civil court. It -is also important for you to understand that, if an unlicensed contractor or employee of an
individual or firm is injured while working on your property, you may be held liable for damages. If you
obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying
whether the contractor is property licensed and the status of the contractor's workers' compensation
coverage.
Property Address:_ » 4c.-NSom _Qy'1-tof/ r& 3271-5
I, o MQJ' V C oa , do hereby state that I am qualified
and capable of performing the requested construction involved with the permit application filed and agree to the
conditions specified above.
Signature of Owner -Builder
Form of Identification
Must be Photo ID)
Date
A violation of this exemption is a misdemeanor of the first degree punishable by a term of imprisonment
not exceeding 1 year and a $1,000.00 fine in addition to any civil penalties. In addition, the local
permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy
for unlicensed activity against the owner and any person performing work that requires licensure under
the permit issued.
Rev. 9.14.2009
REQUIRED INSPECTION SEQUENCE
BP# # 15 - 2 4 4 1 Address: Wfo Wz-W! M Pvwi
BUILDING PERMIT
Min Max Inspection Description
Footer / Setback
Stemwall
Slab / Mono Slab Pre our
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Z0 Frame
70 Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Building Ceiling Air Barrier
Insulation Roof (Com'l)
Building Ceiling Grid
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Final Door
Final Window
Final Screen Room
Final Pool Screen Enclosure
Final Solar
Pre -Demo
Final Demo
Final Single Family Residence
Final Commercial —New
Final Commercial — Addition / Alteration
Final Commercial — Change of Use
Final Building (Other)
REVISED: June 2014
ELECTRICAL PERMIT
Min Max Inspection Description
Electric Underground
Footer / Slab Steel Bond
Electric Ceiling Rough
Electric Wall Rough
Electric Rough
Pre -Power Final
Temporary Pole
Electric Final
PLUMBING PERMIT
Min Max Inspection Description
Roof Storm Drain Rough
Plumbing Underground
Plumbing 2nd Rough
Plumbing Tubset
Plumbing Sewer
Plumbing Grease Trap Rough
Plumbing Steam / Chill Water Rough
Plumbing Final
MECHANICAL PERMIT
Min Max Inspection Description
Mechanical Rough
Mechanical Fire Damper Framing
Mechanical Ceiling Rough
Mechanical Fire Damper Annular Space
Mechanical Insulation Wrap
Mechanical Fire Damper Angle
Light / Water Test Ck Welds
Mechanical Grease Duct Wrap
Mechanical Final
410
NOTICE OF PRODUCT CERTIFICATION
k
Q' r daccAy , ,(
T
fSjF.NT
PFIfl
RECORD COPY
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAM:
COMPANY:
CODE:
NI011624
08/08/2013
Structural
JELD-WEN
822-1
so
To verify that the "Notice of Product Certification' is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
JELD-WEN Builders Aluminum Single Hung
3737 Lakeport Boulevard Window (4100)"
Klamath Falls, OR 97601 w/Flange & Slip -On Nail Fin
Configuration: O/X
Glazing: Monolithic (Annealed) or
Insulating Glass (Annealed)
Frame: W-1324mm(52.13") H-1829mm(72")
Sash: W-1276mm(50.25") H-921mm(36.25")
SPECIFICATION PRODUCT RATING
TAS 202-94 Design Pressure: 2394 Pa (^(
7.!5r,
Negative Design Pressure: 2394
Water Penetration Resistance Test Pressure:
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-3656-1
Expiration Date: January 31, 2018
Administrator's Signature:
SA
O
AAJ
15-2441
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
r
r
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Product Evaluation Report
Of
JELD-WEN, inc.
Builder's Aluminum Single Hung Window
4100 Mechanically Fastened)_
for
Florida Product Approval
Report No. 3032
Current Florida Building Code
398 East Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
Method: 1— A (Certification)
Category: Windows
Sub — Category: Single Hung
Product: Builder's Aluntinunt Single Hung Window
4100 Mechanically Fastened)
Material: Aluminum 6063-T6
Product Dimensions: 52.125"x 72"
Prepared For:
JELD-WEN, inc.
3737 Lakeport Blvd.
Klamath Falls, OR. 97601
Prepared by: . SES F. .
Hermes F. Norero, P.E. •;; •..poFloridaProfessionalEngineer # 73778
Date: 07/23/2014 =
Contents: -v T T =
Evaluation Report Paces 1 — 4
Installation Details Pages 5 — 6 0T D...OP'
N` F
Digitally signed by Hermes F. Norero, P.&,,`SS NAL 1
Cp
Reason: I am approving this document ,,tI
it1jXN-,
Date: 2014.08.14 15:02:25 -04'00'
Hermes F. Norero, P.E.
Florida No. 73778
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Manufacturer:
Product Category:
Product Sub -Category:
Compliance Method:
JELD-WEN, inc.
Windows
Single Hung
State Product Approval Method (1)(a)
Date: 07/23/2014
Report No: 3032
Product Name: Builder's Aluminum Single Hung Window (4100 Mechanically Fastened)
Non -Impact)
52.125" x 72"
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Jeld-Wen Inc.
based on Method 1a of the State of Florida Product Approval, Department of Business and
Professional Regulation - Florida Building Commission.
Limits of Use:
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions BA4100_NCTL_210-3656-1, signed and sealed by Hermes F. Norero, P.E.
FL # 73778) for specific use parameters.
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does require a
I
n impact resistant
covering.
4. Site conditions that deviate from the details of drawing BA4100_NCTL_210-3656-1 require
further engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions BA4100_NCTL_210-3656-1 for size and design pressure
limitations.
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 6
BUILDING DROPS
2014
A Perfect Solution in Every Drop
Date: 07/23
Report No: 3003232
Certificate of Authorization: 29578
Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a quality assurance program audited
by an approved quality assurance entity through National Accreditation and
Management Institute (FBC Organization #: QUA1789)
Performance Standards: The product described herein has been tested per:
TAS 202-94
Referenced Data: 1. Product Testing performed by National Certified Testing Laboratory, Inc.
FBC Organization # TST1589)
Report #: NCTL-210-3656-1, Report Date: 2/24/2010
2. Quality Assurance
National Accreditation and Management Institute
FBC Organization #: QUA1789)
Hermes F. Norero, P.E.
Florida No. 73778
Page 3 of 6
BUILDING DROPS
A\
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Installation: 1. Approved anchor types and substrates areas follows:
Nailing Fin Installation:
Date: 07/23/2014
Report No: 3032
A. For two by (2X) wood frame substrate (Min. S.G. = 0.55), use #8 Wood Screw type wood
frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood
framing.
Through Frame Installation:
A. For two by (2X) wood frame substrate (Min. S.G. = 0.55), use #10 Wood Screw type wood
frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood
framing.
B. For concrete (Min. f c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where
one by (1X), non-structural, wood bucking is employed, use 3/16" diameter ITW Tapcon
type concrete screw anchors of sufficient length to achieve minimum embedment of
1.25" into concrete or masonry.
C. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where
wood bucking is NOT employed, use 3/16" diameter ITW Tapcon type concrete screw
anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or
masonry.
D. For steel substrate (Min 18 Ga., Fy = 33 ksi), use #10 Tek Screw type steel frame anchors
of sufficient length to achieve minimum embedment of 3 threads engagement into steel
framing.
Refer to Installation Instructions (BA4100_NCTL_210-3656-1) for anchor spacing and more details of
the installation requirements.
Design Pressure:
Design Pressure Rating
Positive 50
Negative 50
Hermes F. Norero, P.E.
Florida No. 73778
Page 4 of 6
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Date: 07/23/2014
Report No: 3032
Installation Method
JELD-WEN, inc.
Builder's Aluminum Single Hung Window (4100 Mechanically Fastened)
Through Frame Installation)
r
WINDOW WIDTH (521/8" MAX.) —
4Yj" MAX.
FROM
CORNERS
7"
O.C.
MAX.
Hermes F. Norero, P.E.
Florida No. 73778
Page 5 of 6
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Date: 07/23/2014
Report No: 3032
Installation Method
JELD-WEN, inc.
Builder's Aluminum Single Hung Window (4100 Mechanically Fastened)
Nail Fin Installation)
C
13" O.C._
v
MAX.
WINDOW WIDTH (52v8" MAX.)
412" MAX.
FROM
CORNERS
13"
O.C.
MAX.
Hermes F. Norero, P.E.
Florida No. 73778
Page 6 of 6