HomeMy WebLinkAbout207 Borada RdF
RECF2015__
CITY
OF SANFORD BUILDING &
FIRE PREVENTION PERMIT
APPLICATION Application
No: c / U Documented
Construction Value: $ 7,508.00 Job
Address: 207 Borada Road, Sanford, FL. Historic District: Yes NoEl Parcel ID•
10-20-30-503-0200-0040 Residential Q Commercial Type of
Work: New Addition Alteration Repair Demo Change of Use Move Description of
Work: Roof Replacement - Tamko Heritage Asphalt Shingles - 25 squares Plan Review
Contact Person: Stephanie Title: Admin Phone: 321-
441-2300 Fax: 321-441-2313 Email: swilliams@collisrooftng.
com Property Owner
Information Name John
L. Fowler Phone: 407-323-1728 Street: 207
Borada Road, Resident of
property? : yes City, State
Zip: Sanford, FL,. 32773 Contractor Information
Name Collis
Roofing, Inc. Phone: 321-441-2300 Street: P.
O. Box 520668 Fax: 321-441-2313 City, State
Zip: Longwood, FL. 32752 State License
No.: CCC058022 ArchitectlEngineer Information
Name: n/
a Phone: Street:
Fax:
City, St,
Zip: E-mail: Bonding Company:
n/a Mortgage Lender: n/a Address: Address:
WARNING TO
OWNER: YOUR FAILURE TO RECORD A"NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application
is
hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior
to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this
jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers,
heaters, tanks, and air conditioners, etc. FBC 105.
3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June
30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
8/13/2015
Signature of Owner/Agent Date Signature of ontracto gent 'Date
J. D ugjas Lanier
Print Owner/Agent's Name Print n cloent's Name Signature
of Notary -State of Florida Date u of Notary -State of F Date STEPHANIE
JOY WILLIAMS MY
COMMISSION #EE847705 EXPIRES
October 29, 2016 3
F idallotaryService.com Owner/
Agent is Personally Known to Me or tao71 ersonally Known to Me or Produced
ID Type of ID Produced ID Type of ID BELOW
IS FOR OFFICE USE ONLY Permits
Required: Building Electrical Mechanical Plumbing Gas Roof Construction
Type: Occupancy Use: Total
Sq Ft of Bldg: Min. Occupancy Load: New
Construction: Electric - # of Amps Fire
Sprinkler Permit: Yes No APPROVALS:
ZONING: ENGINEERING:
COMMENTS:
of
Heads UTILITIES:
FIRE:
Flood
Zone: of
Stories: Plumbing - #
of Fixtures Fire
Alarm Permit: Yes No WASTE
WATER: BUILDING:
Revised:
June 30, 2015 Permit Application
Florida's Largest Residential
Roofing Specialist! Longwood 321441-2300
1\ Melbourne 321-751-8850
Q Factory.2raed Q:
ace"COLLIS. Q4lrisured =;» St.
Augustine 904-810-9657 Lakelarui863-
6825700 BBB.
t •• ; _. ,;. ;`.air pp
5,Q aCtOl yCel'tiflCd ; ROOFING rnjo@co/lisroofing.com • trnow.collisroofing.carr Florida
State Cerr fed XooJliT CCoonrra2cror # CCCO58022 ROOFING
CONSULTANT/ESTIMATOR ESTIMATOR'S CELL PHONE #:4% PROPOSAL
PREPARED FOR .. PHONE DATE •--7 NAME /
WORK PHONI + CELLPHONE STREET E-
MAIL
CITY STATE
ZIP
JOB LOCATION
CITY ST EXISTING ROOF
CONDITION y,,.• .,,: ,, ,, ,- 4"
6'
69LLIS;ROOFING SOLUTION+ COMPLETE ROOF PREPARATION - SERVICES PROVIDED TO HELP YO}Ij 1ID ASSLES AND TO PROTECT YOUR HOME O Financing
Months same as Cash, %APR Ma ufarf
cturer WarrantyPEPARATION13re-InspectionYearFullWorkmanshipWarrantywithour factory trained Project Managers. Remove/Replace
Enhanced Mfr's L oue
care taken to protect home exterior, shrubs and landscaping. Obtain and
post local permits in accordance with local laws. 2 ( PYSTColor
10 RemoveScttyleCustomerInitials ,
F existing roof
system to expose decking. 0 Jnspect
decking for rotten and/or deteriorated wood and replace as needed per pricing schedule below. Cg Renail
7s EJSolution #1Subtotal $ '— roof deck
per current codes WOOD REPLACEMENT
COSTS: '5r r Customer Initials v Fo`,COLLIS
RdOFING SOLUTION, #2;',; N Plywood
60ershet,1"deckin $ p 9 - Per linear foot. i/' S
Mantlf'act
W3rran it Fascia (pine/
spruce) $ (cedar) $ J per linear foot. UNDERLAYMENT Year
Full
Workmanship Warranty Dry -In
with undedayment. Install rubberized
leak barrier waterproof membrane in the following areas. 4d' Remove/
Replace Enhanced Eaves Skylights l Valleys IYVent Pipes Wes Warranty
Chimney Crickets Low Slope Other Color Style
Install modified bitumen in dead valleys and low slope areas. Customer Initials
SHINGS Solution #2
Subtotal $ Instcolor inch galvanized or aluminum metal drip edge at eaves & rake edges.
Customer's Initials COLLIS ROOFING SOLUTION•#
3a`',,a5 Install all new lead pipe boot flashings. Manufa urer W
rranty1Z 03n6tall all new
26 gauge galvanized, pre -formed valley metal. Install all kitchen
Year Full Workmanship
Warranty new galvanized and/
or bath fan vents. Replace skylight. Remove/
Replace El
Enhanced Wes Warranty vE
LATION l'
f ridge
vents # Color Style 11stall
Shingle Over
Aluminum L7lnstall oft ridge
ve # Install other venting # Customer Initials Color
n Customer'
s Initia]Xl ___ Solution #3 Subtotal $
RIDGE II all
premium
high definition ridge (required by manufacturer for enhanced wind coverage) Ld Install standard
ridge y, FLAT% LOW
SLOPE SYSTEM ; CLEAN-UP jyl' agnetically sweep
job site Clean out gutters Ed -Haul away all debris to approved facility Year Manufacturer Warranty
Final inspection performed by factory trained Project Manager Q Release of
lien and written warranty provided at time of payment. Year Full Workmanship
Warranty The contractor agrees to commence work hereunder within thirty (30) days after the Color Style last
to occur of the following: (1) the Contractor has received a notice to proceed from the Owner, and (
2) the materials required are available to Contractor. Contractor Customer Initials agrees
to prosecute work thereafter to completion and to complete the work within a reasonable time, subject
to such delays as is permissible under this contract. All Flat / Low Slope
Subtotal $ material is guaranteed as specified. All work will be completed according to standard roofing practices. Any
alteration or deviation from the above specifications involving s0 " o s
extra costs will be executed only upon written order and will become an extra charge Solution Number $ item -
over and
above this agreement. Although we exercise all due caution, we cannot be responsible for
cracked driveways, damages from rain, hail, or any -act God. Any of leaks dueto
workmanship and materials occurring during the Guarantee period will be Flat / Low Slope $
repaired per our written Guarantee. Other $ In the
event that any conflict exists between any estimate of costs of construction and the terms of
this Contract, this Contract shall be controlling. With proper notice to the Owner, Contractor may
substitute materials that are equal in quality to those specified TOTAL INVESTMENT $ if
the Contractor
deems it advisable to do so. 1) Any agreement
or contract for repair, restoration, improvement, or construction to F residential real
property must contain a written statement explaining the consumer's Customer Initials rightsundertherecoveryfund, except where the value of all labor and materials does not exceed $2,
500. The written statement must be substantially in the following form: FLORIDA HOMEOWNERS' CONSTRUCTION
RECOVERY FUND This agreement constitutes
the entire contract by and between Contractor and Owner and the parties are not bound by oral expression or representation
by any party or agent of either party. The above pricing, specifications and conditions are hereby accepted. You are
authorized to do the work as specified. BALANCE IS DUE IN FULL AT TIME OF COMPLETION OF JOB. In case of
late payment or default, a charge of 1.5% per month will apply on all balances over 30 days old. I agree that if Collis Roofing, Inc. is
required to take any action to enforce this contract I shall pay Collis Roofing Inc.'s attorney fees and costs, whether or not
a suit is filed. The price quoted for this proposal shall be good for thirty days or for such longer period at the sole option of theContractor. C CUST I
R SIGNATURE Contract # 031909 Vr' n2;1VAL
Reorder MBF407-657.7414 CR.U01 01/12
City of Sanford
Roof Permit Application Checklist
All permit application packages must be complete prior to acceptance. You must check each box to the
left or indicate n/a on this submittal. A complete application package shall include the following:
Building Permit Application completed, signed and notarized. Application must include correct address
and complete parcel I.D. number.
El Copy of applicable contractor's license issued by the State of Florida (if the contractor is the
applicant).
CJ A site specific notarized power of attorney shall be required from the licensed contractor if
he/she appoints an employee of his/her company to sign the permit application as the contractor.
Certificate of insurance indicating worker's compensation insurance coverage and naming the City of
Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State .of
Florida (must be submitted with each application if contractor is the applicant).
da Completed and signed Owner Builder Statement / Affidavit (if the owner is the applicant).
Tl2P_vP. AftidP.lina.Q wPYP-f)mnilpd to nv.vivt tl]P nnnlirlynt in nrPnnrin0 n rnnf nvrmit nnnlinntinn and mm) not he
LIMITED POWER OF ATTORNEY
Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford,
Seminole County, Winter Springs
Date: 8/13/2015
I hereby name and appoint: Ray Henderson
an agent of: Collis Roofing, Inc.
Name of Company)
to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things
necessary to this appointment for (check only one option):
n The specific permit and application for work located at:
207 Borada Road, Sanford, FL. 32773
Street Address)
Expiration Date for This Limited Power of Attorney:
License Holder Name: J. Douglas Lanier
State License Number: CCC058022
Signature of License Holder:
STATE OF FLORIDA
COUNTY OF seminole
The foregoing instrument was acknowledged before me this day of ,
200 15 , by J. Douglas Lanier who is opersonally known
to me or who has produced as
identification and who did (did not) to oa /, _ ,
Notary Seal)
rats....... STEPHANIE JOY WILLIAMS
MY COMMISSION #EE847705
29, 2016
9,oe,. EXPIRES October
07) 534398A1FloridallotaryService.com Rev.
08.12) Stephanie
J. Williams Print
or type name Notary
Public - State of Florida Commission
No. My
Commission Expires:
THIS INSTRUMENT PREPARED BY:
Name: Stephanie Wiliams
Address: -Collis Roofing, Inc.
P.O. Box 520668, Longwood, FL 39759
NOTICE OF COMMENCEMENT
State of Florida
County of Seminole
Permit Number:
I 10111I1 1III ON HN Nil! ffli 11i - NARYANNE
HORSEY SEMINOLE COUNTY CL.
iRK OF CIRCUIT COURT t. C:ON TRO1_.LER BK
3528 F's 1726 (1Pss) CLERK'
S s 2015090277 RECORDED
08/17,'2015 11:39 20 AN RECORDING
FEES ',•:14.Clil RECORDED
BY hdevore Parcel
ID Number. 10 "110 -30 7 3 " 0a60 -Colf () The
undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter
713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION
OF PROPERTY-j..(
Legal de s cri tion of the property and street address if available Co;
t [3l-lC a r r fJ&Pb•I La1(F- Phl-I Ll ( UPIA- I •PIG a4 P&IS IS' 2 /7 a .
t2 S y.T'Orr'CQ `1 ON
OF IMPROVEMENT: OWNER
INFORMATIO Name:
ic1 v P Address: ("
S -ICI o)) Fee
Simple Title Holder (if other than owner) Name: n/a Address:
CONTRACTOR:
3Name: Collis Roofing, Inc. Address:
P.O. Box 520668, Longwood, FL. 32752 Persons
within the State of Florida Designated by Owner upon whom notice or other documents may be served as
provided by Section 713.13(1)(b), Florida Statutes. Name:
n/a Address:
In
addition to himself, Owner Designates of To
receive a copy of the Lienor's Notice as Provided in Section
713.13(1)(b), Florida Statutes. Expiration
Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different
date is specified) WARNING
TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA
STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.
IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under
penalties of perjury, I declare that 1 have read the foregoing and that the facts stated in it are true N to
the best of my knowledge and belief. 57
Owners
Signature Owners Printed Name •'AD
0
Florida
Statute 713.13 1 x r ( )(g): °The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead. . u o:
o:
U State
of ` iC County of__SC UVti The
foregoing instrument was acknowledged before me this L day of 20 0 a 04by
V l w I 'N Who
is personally known to m1 Q o Nameofpersonmakingstatement0O
OR
who has produced identification type of identification produced: J
STEPHANIE
JOY WILLIAMS MY
COMMISSION #EE847705 r
l EXP[RES October 29, 2016 0
U
I ZI
lid MW
Parcel: 10-20-30-503-0200-0040
SC PA Parcel View: 10-20-30-503-0200-0040
Property Record Card
Parcel: 10-20-30-503-0200-0040
Owner: FOWLER JOHN L & CATHERINE
Property Address: 207 BORADA RD SANFORD, FL 32773
Property Address: 207 BORADA RD
Owner. FOWLER JOHN L & CATHERINE
Mailing: 207 BORADA RD
SANFORD, FL 32773-5540
Subdivision Name: HIDDEN LAKE PH 2 UNIT 1
Tax District: S1-SANFORD
Exemptions: 00-HOMESTEAD (1996)
DOR Use Code: 01-SINGLE FAMILY
Legal Description
LOT 4 BLK 2
HIDDEN LAKE PHASE II UNIT I
PB24PGS 15T017
Taxes
Value Summary
2015 Working
Values
2014 Certified
Values
Valuation Method Cost/Market Cost/Market
Number of Buildings 1 1
Depreciated Bldg Value 59,632 54,049
Depreciated EXFT Value
Land Value (Market) 18,000 15,000
Land ValueAg
st/Market Value
77 632 69 049
Portability Adj
Save Our Homes Adj 13,395 5,322
Amendment 1 Adj
Assessed Value 1 $64,237 63,727
Tax Amount without SOH: $648.27
2014Tax Bill Amount $606.25
Tax Estimator
Save Our Homes Savings: $42.02
w *Does NOT INCLUDE Non Ad Valorem Assessments
Taxing Authority Assessment Value Exempt Values Taxable Value
County General Fund 64,237 39,237 25,000
Schools 64,237 25,000 39,237
City Sanford 64,237 39,237 25,000
SJWM(Saint Johns Water Management) 64,237 39,237 25,000
County Bonds 64,237 39,237 25,000
Sales
Description Date Book Page Amount Qualified Vac/Imp
WARRANTY DEED 1/1/1995 02878 1906 64,500 Yes Improved
WARRANTY DEED 10/I/1990 02237 1688 67,000 Yes Improved
SPECIAL WARRANTY DEED 8/1/1984 01568 1690 100 No Improved
SPECIAL WARRANTY DEED 1/1/1984 01533 0598 100 No Improved
WARRANTY DEED 10/V1981 01399 1126 46,400 Yes Improved
WARRANTY DEED 8/1/1981 01350 0400 45,200 Yes Improved
nnu UariPdrdoieadWSwimin unsauoumsion
Land
Method Frontage Depth Units Units Price Land Value
LOT 0 0 1 18,000.00 18,000
httpJAvww.scpafl.org/ParcelDetailinfo.aspx?PID=10203050302000040 1/2
8/17/2015 Florida Building Code Online
Business a 1 / . 1 . /
NM.
Mtof BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map I Links Search
3usines
Professi I *,.USER:
product Approval
Public User
Regulation
Product Approval Menu > Product or Application Search > Apolication List > Application Detail
OFFICE OFTHE FL # FL1956-R11
Application Type Revision
Code Version 2014
Application Status Approved
Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Depditm
Archived p
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
417) 624-6644 Ext 2305
kerri_eden@tamko.com
9
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J. M. Nieminen, PE
Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard
ASTM D3161
ASTM D3462
ASTM D7158
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Year
2009
2009
2008
httpJ/www.floridabLtilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhE43ULv8xAB4z%2bKOdb010tBw%3d%3d 1/4
8/17/2015
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Florida Building Code Online
03/20/2015
04/02/2015
04/06/2015
FL # Model, Number Description
or Name
1956.1 Elite Glass -Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.0f
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.0f
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II Glass Seal Elite Glass Seal aop inst.odf
used only on roof slopes of 2:12 Verified By: Robert Nieminen 59166
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.2 Glass -Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II Glass Seal Elite Glass Seal app inst.pdf
used only on roof slopes of 2:12 Verified By: Robert Nieminen PE 59166
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.3 Heritage A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.1)df
Approved for use outside FL1956 RI1 C CAC UL certification 10-11-12.odf
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II Heritage D F J P aoo inst.odf
used only on roof slopes of 2:12 FL1956 R11 II Heritage F aoo inst.odf
or greater. Nails must be used FL1956 R11 II Heritage T apt) inst.odf
as the method of attachment. Verified By: Robert J. M. Nieminen FL 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.4 Heritage 30 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.1)df
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.01'
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II heritage 30 aoo inst aoril 10.odf
used only on roof slopes of 2:12 FL1956 R11 II heritage 30 aoo inst f aoril 10.1)df
or greater. Nails must be used Verified By: Robert Nieminen PE 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.5 Heritage 50 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.0f
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 RII II heritage 50 aoo inst agril 10.pdf
used only on roof slopes of 2:12 FL1956 R11 II heritage 50 aop inst f april 10.pdf
or greater. Nails must be used Verified By: Robert Nieminen PE 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
httpJ/www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdb01OtBw%3d%3d 2/4
8117/2015 Florida Building Code ONine
1956.6 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.Ddf
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be
used only on roof slopes of 2:12
or greater. Nails must be used
as the method of attachment.
FL1956 R11 II Heritage. Premium D P aoo inst.ndf
FL1956 R11 II Heritage Premium F aoo inst.pdf
FL1956 R11 II Heritage Premium T app inst.pdf
Verified By: Robert Nieminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.ndf
FL1956 R11 C CAC UL shingle matrix.odfApprovedforuseoutside
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II Heritage Vintage app inst.Ddf
used only on roof slopes of 2:12 Verified By: Robert ]. M. Nieminen PE 59166
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.8 Heritage Vintage Hip and ridge shingles
12 X 12 Hip and
Ridge
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.Ddf
FL1956 R11 C CAC UL shingle matrix.odfApprovedforuseoutside
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II TAMKOCg) Heritage(g) 12 x 12 Hip and Ridge Application Instructions. pdf
Verified By: Robert 1. M. Nieminen PE 59166usedonlyonroofslopesof2:12
or greater. Nails must be used Created by Independent Third Party: No
as the method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.9 Heritage A dimensional asphalt shingle.
Woodgate
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.p_df
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II Heritage Woodgate D app inst.odf
used only on roof slopes of 2:12 FL1956 R11 II Heritage Woodgate F app inst.pdf
or greater. Nails must be used Verified By: Robert Nieminen 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.10 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.odf
HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: N/A 10/10/2015
Design Pressure: N/A Installation Instructions
Other: Asphalt shingles shall be FL1956 R11 II heritage A app inst d april Modf
used only on roof slopes of 2:12 FL1956 R11 II heritage xl app inst f aoril 10.Pdf
or greater. Nails must be used Verified By: Robert Nieminen PE 59166
as the method of attachment. Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.11 Hip and Ridge Hip and ridge shingles
Shingles
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf
Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.i)df
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdb01OtBw%3d%3d 3/4
8/17/2015 Florida Building Code Online
HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Hip and Ridge shingles
shall be used only on roof slopes
of 2:12 or greater. Nails must
be used as the method of
attachment.
Quality Assurance Contract Expiration Date
10/10/2015
Installation Instructions
FL1956 R11 II 12.25x12 Hip and Ridge.Ddf
FL1956 R11 II 12 x 12 Hip Ridge Application Instructions. Ddf
FL1956 R11 II 12-1-4x12 HipRidge Sealant Dab Illustrations.pdf
FL1956 R11 II 12x12 HipRidge Sealant Dab Illustrations, odf
Verified By: Robert Nieminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
W
CreditSAFECard
http://www.floridabLildirig.orglpr/pr ppp dtl.aspx?param=wGEVXQwtDgsg/o2fnGFoyT6raQg/o2bp/o2bCXWUhEA3ULv&AB4zp/o2bKOdbOlOtBwp/o3dg/o3d 4/4
Application Instructions for FORMERLY HERITAGE® 30
TAMKO HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHA6T SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY. SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY, THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER (BELOW 40"F), CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT It is not necessary to remove the plastic strip from the back of the shingles.
1. ROOF DECK
These shingles are for application to roof decks consisting of plywood
or sheathing boards capable of receiving and retaining fasteners, and
to inclines of not less than 2 in. per foot. For roofs having pitches 2 in.
per foot to less than 4 in. per foot, refer to special instructions titled
Low Slope Application". For roofs having pitches greater than 21 in.
per foot, refer to special instructions titled "Mansard Roof or Steep
Slope Roof". Shingles must be applied properly. TAMKO assumes no
responsibility for leaks or defects resulting from improper application,
or failure to properly prepare the surface to be roofed over.
NEW ROOF DECK CONSTRUCTION: Roof deck must be smooth,
dry and free from warped surfaces. It is recommended that metal
drip edges be installed at eaves and rakes.
PLYWOOD: All plywood shall be exterior grade as defined by
APA - The Engineered Wood Association. Plywood shall be a
minimum of 3/8 in. thickness and applied in accordance with the
recommendations of APA - The Engineered Wood Association.
SHEATHING BOARDS: Boards shall be well -seasoned tongue -
and -groove boards and not over 6 in. nominal width. Boards shall
be a 1 in. nominal minimum thickness. Boards shall be properly
spaced and nailed.
2. VCHTIWITION
Inadequate ventilation of attic spaces can cause accumulation of
moisture in winter months and a build up of heat in the summer.
These conditions can lead to:
1. Vapor Condensation
2. Buckling of shingles due to deck movement.
3. Rotting of wood members.
4. Premature failure of roof.
To insure adequate ventilation and circulation of air, the ventilation
system must include inlets and outlets. This may be accomplished with
a combination of ridge and soffit vents or by using gable end vents.
FHA minimum property standards require one square foot of net free
ventilation area to each 150 square feet of space to be vented. This
may be reduced to one square foot of ventilation area per 300 square
feet if at least 40% and not more than 50% of venting is provided
not more than 3 feet below the ridge or if a Class I or II vapor barrier
is installed on the warm in winter side of the ceiling in climate zones
6, 7, and 8 as recommended by the 2012 International Residential
Code. For more information consult your design professional. If the
ventilation openings are screened, the total area should be doubled.
IT IS PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION,
3. FASTENERS
WIND CAUTION: Extreme wind velocities can damage these
shingles after application when proper sealing of the shingles does
not occur. This can especially be a problem if the shingles are applied
in cooler months or in areas on the roof that do not receive direct
sunlight. These conditions may impede the sealing of the adhesive
strips on the shingles. The inability to seal down may be compounded
by prolonged cold weather conditions and/or blowing dust. In these
situations, hand sealing of the shingles is required. To insure quicker
sealing, apply 4 quarter -sized dabs of TAM -PRO® SBS Flashing
Cement, TAMKO or TAM -PRO® Plastic Roof Cement, or TAMKO
Tam -Seal Adhesive, meeting ASTM D 4586, Type 1, on the back of
the shingle 1 in. (25mm) and 13 in. (330mm) in from each side and
1 in. (25mm) up from the bottom of the shingle. Press shingle firmly
into the adhesive. For maximum wind resistance along rakes, install
any TAMKO starter shingle including sealant or cement shingles to
the underlayment and each other in a 4 in. (102mm) widtKof TAM-
PROO SBS Flashing Cement, TAMKO or TAM-PR00 Plastic Roof
Cement, or TAMKO Tam -Seal Adhesive. Caution: Apply ONLY a thin
uniform layer of adhesive less than 1/8 in. (3mm) thick. Excessive
amounts can cause blistering of the shingles and may soften the
asphalt in certain underlayments resulting in the asphalt flowing,
dripping and staining. Shingles must also be fastened according to
the fastening instructions described below.
Correct placement of the fasteners is critical to the performance of
the shingle. If the fasteners are not placed as shown in the diagram
and described below, this will result in the termination of TAMKO's
liabilities under the Limited Warranty. TAMKO will not be responsible
for damage to shingles caused by winds in excess of the applicable
mph as stated in the Limited Warranty. See Limited Warranty on the
wrapper or tamko.com for details.
FASTENING PATTERNS: Fasteners must be placed 6-1/8 in. from
the bottom edge of the shingle, penetrating through the common
bond, and located horizontally as follows:
1) Standard Fastening Pattern. (For use on decks with slopes 2
in, per foot to 21 in. per foot.) One fastener 1 in. from each end and
one 13-1/2 in. from each end of the shingle for a total of 4 fasteners.
See Standard Fastening Pattern illustrated below).
STANDARD FASTENING PATTERN
FASTENERS NAIL ZONE
COMMON
BOND
6-1i/8"I I I I I I I I EXPO
iLIRE 5-5/8"
12-1/2"—+— 12-3/8" — 12-1/2"-- h-1"
Continued)
Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 D9/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656
tamko.com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 1
CONTINUED from page 1) FORMERLY HERITAGE® 30
TAMKO HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
2) Mansard Fastening Pattern. (For use on decks with slopes
greater than 21 in. per foot.) One fastener 1 in. from each end and
one fastener 8-1/2 in, from each end and one fastener 16 in. from
each end for a total of 6 fasteners per shingle. (See Mansard and
High Wind Fastening Pattern illustrated below.)
MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN
FASTENERS NAIL ZONE
COMMON
BOND
6-18" EXPOSURE 5-5B"
h-i-nu h--irz'-•Ir -ala"-IFS-R"-I-rz"I I-.
3) High Wind Warranty Fastening Pattern. (For High Wind Warranty
Application requirements) One fastener 1 in. from each end. One
fastener 8-1/2 in. from each end and one fastener 16 in. from each
end for a total of six (6) fasteners per shingle. In addition to this
shingle fastening pattern requirement for High Wind Application,
TAMKO also requires the use of TAMKO starter shingles including
sealant strip at eaves and rakes. Alternatively, along rakes, cement
shingles to the underlayment and each other in a 4 in. (102 mm)
width of TAM -PRO@ SBS Flashing Cement, TAMKO or TAM -PRO®
Plastic Roof Cement, orTAMKO Tam -Seal Adhesive. Caution: Apply
ONLY a thin uniform layer of adhesive less than 1/8 in. (3mm) thick.
Excessive amounts can cause blistering of the shingles and may
soften the asphalt in certain underlayments resulting in the asphalt
flowing, dripping and staining.
High Wind Application is offered on new construction or complete
tear -off applications only. It is not offered for recover applications.
If High Wind Application requirements are not followed, the High
Wind Application Warranty MPH, as stated on Table I in the Limited
Warranty, reverts to the Standard Application Wind Warranty MPH
limit. (See Mansard and High Wind Fastening Pattern illustrated
above.)
NAILS: TAMKO recommends the use of nails as the preferred method
of application. Standard type roofing nails should be used. Nail
shanks should be made of minimum 12 gauge wire, and a minimum
head diameter of 3/8 in. Nails should be long enough to penetrate
3/4 in. into the roof deck. Where the deck is less than 3/4 in. thick,
the nails should be long enough to penetrate completely through
plywood decking and extend at least 1/8 in. through the roof deck.
Drive nail head flush with the shingle surface.
Property Driven Improporty Driven
3W min diameter undeni&en ovordriven crooked
Asphalt
shingles
Decking
I{
1/4' nominal
freight, good penetration, Inadequate too deep, cuts Inadequate
end flush with shingle surface penetration Into shingle anchorage
STAPLES: If staples are used in the attaching process, follow the
above instructions for placement. All staples must be driven with
pneumatic staplers. The staple must meet the following minimum
dimensional requirements. Staples must be made from a minimum
16 gauge galvanized wire. Crown width must be at least 15/16 in.
staple crown width is measured outside the legs). Leg length should
be a minimum of 1-1/4 in. for new construction and 1-1/2 in. for
reroofing thus allowing a minimum deck penetration of 3/4 in. The
Properly Driven Improperly Driven
underdnven overdriven crooked
eiI
Asphalt
Shingles
Decking
h min.
crown of the staple must be parallel to the length of the shingle.
The staple crown should be driven flush with the shingle surface.
Staples that are crooked, underdriven or overdriven are considered
improperly applied.
CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE
NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING
PATTERN DIAGRAMS.
4. ONDERIMMENT
UNDERLAYMENT. An underlayment must be applied over the
entire deck before the installation of TAMKO shingles. Failure to add
underlayment can cause premature failure of the shingles which is
not covered by TAMKO'S Limited Warranty.
Products which are acceptable for use as underlayment are:
Asphalt Saturated Felt Underlayments:
SuperX 30TM Underlayment
TAMKO No. 15 Asphalt Saturated Organic Felt
Any TAMKO non -perforated asphalt saturated organic felt
A non -perforated asphalt saturated organic felt which meets
ASTM: D226, Type I or II or ASTM D4869
Specialty Underlayments:
Tam -Shield® Synthetic Underlayment or Synthetic Shield
Underlayment
TAMKO TW Metal and Tile Underlayment, TW Underlayment
and Moisture Guard Plus@ (additional ventilation may be
required. Contact TAMKO's Technical Services Department
for more information.)
A self-adhesive underlayment designed for use with asphalt
shingles which meets ASTM D1970.
For Asphalt Saturated Felt Underlayments:
Apply the felt when the deck is dry. On roof decks with slopes
4 in. per foot and greater apply the felt parallel to the eaves
lapping each course of the felt over the lower course at least
2 in. Where ends join, lap the felt 4 in. If left exposed, the felt
may be adversely affected by moisture and weathering. Laying
of the felt and the shingle application must be done together.
For All Other Specialty Underayments:
On roof decks with slopes 4 in. per foot and greater apply
the underlayment parallel to the eaves in accordance
with underlayment written application instructions. The
underlayment should not be left exposed for a longer period of
time than is specified in the underlayments written application
instructions. The final roof covering must be installed before
the structure is exposed to adverse weather conditions, such
as wind driven rain, high wind, hail, ice storms, etc. (Continued)
Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656
tamko.Com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 2
CONTINUED from page 2) FORMERLY HERITAGE® 30
11 &IMI&V I HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO * Phillipsburg, KS
In areas where ice builds up along the eaves or a back-up of water
from frozen or clogged gutters is a potential problem, TAMKO's
Moisture Guard Plus®, TW Metal and Tile Underlayment or TW
Underlayment (or any specialty eaves flashing product) may be
applied to eaves, rakes, ridges, valleys, around chimneys, skylights
or dormers to help prevent water damage. Contact TAMKO's
Technical Services Department for more information.
Substitute products as shingle underlayment should not be used.
6. APPLICATION INSTRUCTIONS
STARTER COURSE: A starter course may consist of TAMKO Shingle
Starter, TAMKO 10-inch Starter or self-sealing 3-tab shingles. If self-
sealing 3-tab shingles are used, remove the exposed tab portion and
install with the factory applied adhesive adjacent to the eaves. Attach
the starter course with approved fasteners along a line parallel to
and 1.5 in. to 3 in. above the eaves edge. The starter course should
overhang both the eaves and rake edges 1/4 in. to 3/8 in. if drip edge
flashing is not used along the eaves or rakes. If drip edge flashing
is present, install shingles even with the drip edge.
For maximum wind resistance along rakes, Install any
Drip
edge
Rake
Fastenors klocated1.12'to 3'
tromrekeedge '
Start that strip with 12 Shingle Starter strips overhang Sea-.easng Eave Feztenors D.P edge
removed, than follow with tull eaves and rakes AM"- located
strips In order Isoffset with the 114" to 3/9. 6 no drip edge positioned 1.12' 1.3'
fir. shingle course. gashing o present u drip along eaves from eave edge
edge gashing is present. or rake edge
instal shingles even with
drip edge.
SHINGLE APPLICATION: Start the first course with a full size shingle
and overhang the rake edge 1/4 in. if drip edge is not present. If
drip edge is present, align shingle edge with drip edge flashing. Cut
10-3/8 in. from a full shingle to form a shingle 29 in. long. Use this
to start the second course (see diagram below). Cut a 23 in. long
shingle to start the third course. Use the remaining 16-3/8 in. piece
bare"
Y;th
repeat 103/8" : ;; _•
4,
courses its-3/8° I
t
E
16-3/8" 23.
5th course
4th course
3rd course
2nd course
1st course
t—eave
23" 1B-MI
10-3/8"
of shingle to start the fourth course and use the remaining 10-3/8
in. piece to begin the fifth course. Continue up the rake in as many
rows as necessary using the same formula as outlined above.
The butt of the shingle should be aligned with the top edge of the
sawtooth of the underlying shingle for a 5-5/8 in. exposure (see
shingle application drawing illustrated on this panel). When you
make your final cut at the roof's edge, flip any pieces that are 8 in. or
longer back onto the roof. These pieces can be worked in anywhere
without creating zippers or color variations.
NOTE: Do not align joints of shingle courses when working in cut
pieces. Joints should be no closer than 4 in. from one another.
Cut your first coun:e shingle to make 29' end a 10 318'
length. Cut a second shingle to make a 23' and
A 16 3W length.
i103B' - \
1.
17
2.ThBegin spy tafion wdh a tug length shingle.
en by your 29', 23'. 16 318' and 10 3/6' lengths,
As you can seo, three shingles with two cuts
make five courses. _
3Conume working your way across the mol. When you make your Malcutattherootsedge, fkp any pieces that am 8" or longer back
onto the mot. These pieces can be worked in anywhere without creating
zippers or color variations. NOTE:
Do not align joint. of shingle course. when working in cut
places. Joints should be no closer than 4" from one Another. 6.
LOW SLOPS APPLICATION On
pitches 2 in. per foot to 4 in. per foot cover the deck with two layers
of underlayment. Begin by applying the underlayment in a 1/
2-sheet width along the eaves and overhanging the drip edge by
1/4 to 3/4 in. Place a full -sheet width over the 1/2-sheet width starter
piece, completely overlapping it. All succeeding courses will be
positioned to overlap the preceding course by 1/2-sheet width. If
winter temperatures average 25AF or less, thoroughly cement the
laps of the entire underlayment to each other with TAM -PRO or
TAMKO Plastic Roof Cement from eaves and rakes to a point of
a least 24 in. inside the interior wall line of the building. As an alternative,
TAMKO's Moisture Guard Plus®, TW Metal and Tile Underlayment,
or TW Underlayment self -adhering underlayment may
be used in lieu of the cemented felts. 7.
MANSARD ROOF OR STSSP SLOPC ROOF If
the slope exceeds 21 in. per foot (60), each shingle must be sealed with
TAM -PROD SBS Flashing Cement, TAMKO or TAM -PRO® Plastic
Roof Cement, or TAMKO Tam -Seal Adhesive immediately upon
installation. Quarter -sized dabs of cement or adhesive must be
applied to shingles with a 5-5/8 in. exposure, use 6 fasteners per shingle.
See Section 3 for the Mansard Fastening Pattern. Continued)
Central
District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14 Visit
Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast
District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko.
eom Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western
District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 3
CONTINUED from page 3) , FORMERLY HERITAGE® 30
I -rhmnu I HERITAGE"
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
8. RE -ROOFING
Before re -roofing, be certain to inspect the roof decks. All plywood shall
meet the requirements listed in Section 1.
It is not recommended to install laminated asphalt shingles directly
over existing laminated shingles due to the unevenness of the existing
multi -layered shingles. The performance of the sealant feature may be
compromised, preventing the shingles from sealing properly. It is
acceptable to install laminated shingles over existing three -tab strip
shingles which are flat and essentially intact. Nail down or remove curled
or broken shingles from the existing roof. Replace all missing shingles
with new ones to provide a smooth base. Shingles that are buckled
usually indicate warped decking or protruding nails. Hammer down all
protruding nails or remove them and refasten in a new location. Remove
all drip edge metal and replace with new.
If re -roofing over an existing roof where new flashing is required to
protect against ice dams (freeze/thaw cycle of water and/or the backup
of water in frozen or clogged gutters), remove the old roofing to a point
at least 24 in. beyond the interiorwall line and apply TAMKO's Moisture
Guard Plus®, TW Metal and Tile Underlayment, or TW Underayment.
Contact TAMKO's Technical Services Department for more information.
Measurements will vary when nesting over an existing 5 in. exposure
single roof: Call TAMKO Technical Services for further information.
The nesting procedure described below is the preferred method for
reroofing over existing metric size shingles with a 5-5/8 in. exposure.
See description below:
Starter Course: Remove the tabs and an additional portion from the
head of a full size shingle so that its height is equal to the exposure of
the existing shingles. Position the resulting strip over the existing roof
edge (with the factory -applied adhesive strip along the eaves). Cut
approximately 6 in. from the rake end and apply the remaining portion at
the eaves. Continue the starter strip by applying full length shingle strips
cut to height as above, evenly along the existing roof at the eaves. The
existing roof should overhang the eaves far enough to carry water
off into the gutter. If this is not the case, cut and apply the starter
strip so that it will provide sufficient overhang for proper drainage.
Dnp
First Course: Remove an amount from the butt edge of afull-size shingle
so that the remaining portion of the shingle fits between the butts of the
existing third course. This course must also be applied evenly along the
eaves edge of the new starter strip.
Second and Succeeding Courses: Remove 10-3/8 in. from the rake
end of the first shingle in the second course, and continue with full
width shingles for the remainder of the course, placing the top edge of
each new shingle against the butt edge of the old shingle in the course
above. This method should create an exposure of 5-5/8 in. after the first
course. When beginning the succeeding courses continue to follow the
Heritage application instructions. (See section 5).
8. VALLEY APPLICATION
Overthe shingle underlayment, center a minimum 36 in. wide sheet of
Moisture Guard Plus®, TW Metal & Tile Underlayment, or a minimum
50 lb. roll roofing in the valley. Nail the underlayment only where
necessary to hold it in place and then only nail the outside edges.
IMPORTANT: PRIOR TO INSTALLATION WARM SHINGLES TO
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING
SHINGLES TO FORM VALLEY.
After valley flashing is in place:
Apply the first course of shingles along the eaves of one of the
intersecting roof planes and across the valley.
Note: For proper flow of water over the trimmed shingle, always
start applying the shingles on the roof plane that has the lower
slope or less height.
Extend the end shingle at least 12 in. onto the adjoining roof.
Apply succeeding courses in the same manner, extending them
across the valley and onto the adjoining roof.
Press the shingles tightly into the valley.
Use normal shingle fastening methods.
Note: No fastener should be within 6 in. of the valley centerline,
and two fasteners should be placed at the end of each shingle
crossing the valley.
To the adjoining roof plane, apply one row of shingles vertically
facing the valley and 2 in, back from the valley centerline.
Note: For a neater installation, snap a chalkline over the
shingles for guidance.
To complete the valley, apply shingles on the adjoining roof
plane by positioning the tip of the first shingle of each row at
the 2 in. point from the centerline where the edge of the vertical
shingle has been applied, covering the vertical shingle.
Minimum 36" wide sheet
of Moisture Guard Plus,
TW Metal &
Tile orheavle
Underfayment
Valleycenterline t
Extra nail in Place
up or shingle on toe eoge or the
vertical shingle, 2 Inches back from
valley centerline and covering the
vertical shingle. Extend
end shingle 12"-
16"beyond vdley
centerline No
fasteners within 6"
of centerline FOR
ALTERNATE VALLEY APPLICATION METHODS, PLEASE CONTACT
TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800-
641-4691. Continued)
Central
District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14 Visit
Our Web Site at Northeast
District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast
District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko.
com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western
District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 4
CONTINUED from page 4) FORMERLY HERITAGE® 30
1 IL &&1R1&iU.. HERITAGE®
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
10. HIP AND RIDGE FASTENING DCTAII,
Apply the shingles with a 5-1/8 in. exposure beginning at the bottom
of the hip or from the end of the ridge opposite the direction of the
prevailing winds. Secure each shingle with one fastener on each side,
5-5/8 in. back from the exposed end and 1 in. up from the edge.
TAMKO recommends the use of TAMKO Hip & Ridge shingle
products. Where matching colors are available, it is acceptable to
use TAMKO's Elite Glass -Seal shingles cut down to 12 in. pieces.
Fasteners should be 1/4 in. longer than the one used for shingles
IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE
TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
BENDING SHINGLE IN COLD WEATHER.
Direction prevailing wind
THESE ARE THE MANUFACTURER'S APPLICATION
INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES
NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE
UNDER THE LIMITED WARRANTY. SEE THE LIMITED
WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Information Included in these application Instructions was current at time of printing. To
obtain a copy of the most current version of these application Instructions, visit us online
at tamko.com or call us at 800-641-4691.
TAMKO®, Moisture Guard Plus®, Tam -Shield®, TAM -PROS and Heritage® are registered
trademarks and SuperX 30 is a trademark of TAMKO Building Products, Inc.
Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656
tamko.Com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 5
JP69909
I
jr
CITY OF SANFORD BUILDING SERVICES
Residential Re -Roof
Hurricane Mitigation Inspection Affidavit
Permit #: 1_. ' 2'1(e (y
I, J. Douglas Lanier
hereby acknowledge that I •personally inspected
Roof deck nailing and/or Secondary water barrier work
at 207 Borada Road, Sanford, FL. 32773 and have determined that the work
Job Site Address)
was done according to the Hurricane Mitigation Retrofit Manual. (based on 553.844 F.S.)
I certify that my statements herein are true and accurate to the best of my belief and that I fully
understand that making any false statements in writing with the intent to mislead a public servant in the
performance of his or her official duty shall constitute a misdemeanor of the second degree pursuant to
Section 837 6F.S.
Signature o Contractor Date
J. Douglas Lanier
Printed Name of Contractor
CCC058022
License #
License Type: General Building D Residential 29 Roofing Contractor
or any individual certified in accordance with F.S. 468 to make such an inspection.
STATE OF FLORIDA COUNTY OF Seminole A6) tSwornto ( r • firme ) and subscribed before me this day of 20 15 , by
J. Dougl ier who is Persona Known to me or has 0 Produced (type of
identi as identification.
SEAL)
Signs a of 6D6ry Afilic
State of Florida
Stephanie J. Williams
Print/Type/Stamp Name
of Notary Public STEPHANIE JOY WILLIAMS
MY COMMISSION #EE847705oQ
7,' oQ•' OF F<. EXPIRES October 29, 2016
407) 398-0153 FloridaNOtaryService.com