Loading...
HomeMy WebLinkAbout207 Borada RdF RECF2015__ CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: c / U Documented Construction Value: $ 7,508.00 Job Address: 207 Borada Road, Sanford, FL. Historic District: Yes NoEl Parcel ID• 10-20-30-503-0200-0040 Residential Q Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: Roof Replacement - Tamko Heritage Asphalt Shingles - 25 squares Plan Review Contact Person: Stephanie Title: Admin Phone: 321- 441-2300 Fax: 321-441-2313 Email: swilliams@collisrooftng. com Property Owner Information Name John L. Fowler Phone: 407-323-1728 Street: 207 Borada Road, Resident of property? : yes City, State Zip: Sanford, FL,. 32773 Contractor Information Name Collis Roofing, Inc. Phone: 321-441-2300 Street: P. O. Box 520668 Fax: 321-441-2313 City, State Zip: Longwood, FL. 32752 State License No.: CCC058022 ArchitectlEngineer Information Name: n/ a Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: n/a Mortgage Lender: n/a Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A"NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 8/13/2015 Signature of Owner/Agent Date Signature of ontracto gent 'Date J. D ugjas Lanier Print Owner/Agent's Name Print n cloent's Name Signature of Notary -State of Florida Date u of Notary -State of F Date STEPHANIE JOY WILLIAMS MY COMMISSION #EE847705 EXPIRES October 29, 2016 3 F idallotaryService.com Owner/ Agent is Personally Known to Me or tao71 ersonally Known to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application Florida's Largest Residential Roofing Specialist! Longwood 321441-2300 1\ Melbourne 321-751-8850 Q Factory.2raed Q: ace"COLLIS. Q4lrisured =;» St. Augustine 904-810-9657 Lakelarui863- 6825700 BBB. t •• ; _. ,;. ;`.air pp 5,Q aCtOl yCel'tiflCd ; ROOFING rnjo@co/lisroofing.com • trnow.collisroofing.carr Florida State Cerr fed XooJliT CCoonrra2cror # CCCO58022 ROOFING CONSULTANT/ESTIMATOR ESTIMATOR'S CELL PHONE #:4% PROPOSAL PREPARED FOR .. PHONE DATE •--7 NAME / WORK PHONI + CELLPHONE STREET E- MAIL CITY STATE ZIP JOB LOCATION CITY ST EXISTING ROOF CONDITION y,,.• .,,: ,, ,, ,- 4" 6' 69LLIS;ROOFING SOLUTION+ COMPLETE ROOF PREPARATION - SERVICES PROVIDED TO HELP YO}Ij 1ID ASSLES AND TO PROTECT YOUR HOME O Financing Months same as Cash, %APR Ma ufarf cturer WarrantyPEPARATION13re-InspectionYearFullWorkmanshipWarrantywithour factory trained Project Managers. Remove/Replace Enhanced Mfr's L oue care taken to protect home exterior, shrubs and landscaping. Obtain and post local permits in accordance with local laws. 2 ( PYSTColor 10 RemoveScttyleCustomerInitials , F existing roof system to expose decking. 0 Jnspect decking for rotten and/or deteriorated wood and replace as needed per pricing schedule below. Cg Renail 7s EJSolution #1Subtotal $ '— roof deck per current codes WOOD REPLACEMENT COSTS: '5r r Customer Initials v Fo`,COLLIS RdOFING SOLUTION, #2;',; N Plywood 60ershet,1"deckin $ p 9 - Per linear foot. i/' S Mantlf'act W3rran it Fascia (pine/ spruce) $ (cedar) $ J per linear foot. UNDERLAYMENT Year Full Workmanship Warranty Dry -In with undedayment. Install rubberized leak barrier waterproof membrane in the following areas. 4d' Remove/ Replace Enhanced Eaves Skylights l Valleys IYVent Pipes Wes Warranty Chimney Crickets Low Slope Other Color Style Install modified bitumen in dead valleys and low slope areas. Customer Initials SHINGS Solution #2 Subtotal $ Instcolor inch galvanized or aluminum metal drip edge at eaves & rake edges. Customer's Initials COLLIS ROOFING SOLUTION•# 3a`',,a5 Install all new lead pipe boot flashings. Manufa urer W rranty1Z 03n6tall all new 26 gauge galvanized, pre -formed valley metal. Install all kitchen Year Full Workmanship Warranty new galvanized and/ or bath fan vents. Replace skylight. Remove/ Replace El Enhanced Wes Warranty vE LATION l' f ridge vents # Color Style 11stall Shingle Over Aluminum L7lnstall oft ridge ve # Install other venting # Customer Initials Color n Customer' s Initia]Xl ___ Solution #3 Subtotal $ RIDGE II all premium high definition ridge (required by manufacturer for enhanced wind coverage) Ld Install standard ridge y, FLAT% LOW SLOPE SYSTEM ; CLEAN-UP jyl' agnetically sweep job site Clean out gutters Ed -Haul away all debris to approved facility Year Manufacturer Warranty Final inspection performed by factory trained Project Manager Q Release of lien and written warranty provided at time of payment. Year Full Workmanship Warranty The contractor agrees to commence work hereunder within thirty (30) days after the Color Style last to occur of the following: (1) the Contractor has received a notice to proceed from the Owner, and ( 2) the materials required are available to Contractor. Contractor Customer Initials agrees to prosecute work thereafter to completion and to complete the work within a reasonable time, subject to such delays as is permissible under this contract. All Flat / Low Slope Subtotal $ material is guaranteed as specified. All work will be completed according to standard roofing practices. Any alteration or deviation from the above specifications involving s0 " o s extra costs will be executed only upon written order and will become an extra charge Solution Number $ item - over and above this agreement. Although we exercise all due caution, we cannot be responsible for cracked driveways, damages from rain, hail, or any -act God. Any of leaks dueto workmanship and materials occurring during the Guarantee period will be Flat / Low Slope $ repaired per our written Guarantee. Other $ In the event that any conflict exists between any estimate of costs of construction and the terms of this Contract, this Contract shall be controlling. With proper notice to the Owner, Contractor may substitute materials that are equal in quality to those specified TOTAL INVESTMENT $ if the Contractor deems it advisable to do so. 1) Any agreement or contract for repair, restoration, improvement, or construction to F residential real property must contain a written statement explaining the consumer's Customer Initials rightsundertherecoveryfund, except where the value of all labor and materials does not exceed $2, 500. The written statement must be substantially in the following form: FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND This agreement constitutes the entire contract by and between Contractor and Owner and the parties are not bound by oral expression or representation by any party or agent of either party. The above pricing, specifications and conditions are hereby accepted. You are authorized to do the work as specified. BALANCE IS DUE IN FULL AT TIME OF COMPLETION OF JOB. In case of late payment or default, a charge of 1.5% per month will apply on all balances over 30 days old. I agree that if Collis Roofing, Inc. is required to take any action to enforce this contract I shall pay Collis Roofing Inc.'s attorney fees and costs, whether or not a suit is filed. The price quoted for this proposal shall be good for thirty days or for such longer period at the sole option of theContractor. C CUST I R SIGNATURE Contract # 031909 Vr' n2;1VAL Reorder MBF407-657.7414 CR.U01 01/12 City of Sanford Roof Permit Application Checklist All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. El Copy of applicable contractor's license issued by the State of Florida (if the contractor is the applicant). CJ A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State .of Florida (must be submitted with each application if contractor is the applicant). da Completed and signed Owner Builder Statement / Affidavit (if the owner is the applicant). Tl2P_vP. AftidP.lina.Q wPYP-f)mnilpd to nv.vivt tl]P nnnlirlynt in nrPnnrin0 n rnnf nvrmit nnnlinntinn and mm) not he LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 8/13/2015 I hereby name and appoint: Ray Henderson an agent of: Collis Roofing, Inc. Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): n The specific permit and application for work located at: 207 Borada Road, Sanford, FL. 32773 Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: J. Douglas Lanier State License Number: CCC058022 Signature of License Holder: STATE OF FLORIDA COUNTY OF seminole The foregoing instrument was acknowledged before me this day of , 200 15 , by J. Douglas Lanier who is opersonally known to me or who has produced as identification and who did (did not) to oa /, _ , Notary Seal) rats....... STEPHANIE JOY WILLIAMS MY COMMISSION #EE847705 29, 2016 9,oe,. EXPIRES October 07) 534398A1FloridallotaryService.com Rev. 08.12) Stephanie J. Williams Print or type name Notary Public - State of Florida Commission No. My Commission Expires: THIS INSTRUMENT PREPARED BY: Name: Stephanie Wiliams Address: -Collis Roofing, Inc. P.O. Box 520668, Longwood, FL 39759 NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: I 10111I1 1III ON HN Nil! ffli 11i - NARYANNE HORSEY SEMINOLE COUNTY CL. iRK OF CIRCUIT COURT t. C:ON TRO1_.LER BK 3528 F's 1726 (1Pss) CLERK' S s 2015090277 RECORDED 08/17,'2015 11:39 20 AN RECORDING FEES ',•:14.Clil RECORDED BY hdevore Parcel ID Number. 10 "110 -30 7 3 " 0a60 -Colf () The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY-j..( Legal de s cri tion of the property and street address if available Co; t [3l-lC a r r fJ&Pb•I La1(F- Phl-I Ll ( UPIA- I •PIG a4 P&IS IS' 2 /7 a . t2 S y.T'Orr'CQ `1 ON OF IMPROVEMENT: OWNER INFORMATIO Name: ic1 v P Address: (" S -ICI o)) Fee Simple Title Holder (if other than owner) Name: n/a Address: CONTRACTOR: 3Name: Collis Roofing, Inc. Address: P.O. Box 520668, Longwood, FL. 32752 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: n/a Address: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that 1 have read the foregoing and that the facts stated in it are true N to the best of my knowledge and belief. 57 Owners Signature Owners Printed Name •'AD 0 Florida Statute 713.13 1 x r ( )(g): °The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead. . u o: o: U State of ` iC County of__SC UVti The foregoing instrument was acknowledged before me this L day of 20 0 a 04by V l w I 'N Who is personally known to m1 Q o Nameofpersonmakingstatement0O OR who has produced identification type of identification produced: J STEPHANIE JOY WILLIAMS MY COMMISSION #EE847705 r l EXP[RES October 29, 2016 0 U I ZI lid MW Parcel: 10-20-30-503-0200-0040 SC PA Parcel View: 10-20-30-503-0200-0040 Property Record Card Parcel: 10-20-30-503-0200-0040 Owner: FOWLER JOHN L & CATHERINE Property Address: 207 BORADA RD SANFORD, FL 32773 Property Address: 207 BORADA RD Owner. FOWLER JOHN L & CATHERINE Mailing: 207 BORADA RD SANFORD, FL 32773-5540 Subdivision Name: HIDDEN LAKE PH 2 UNIT 1 Tax District: S1-SANFORD Exemptions: 00-HOMESTEAD (1996) DOR Use Code: 01-SINGLE FAMILY Legal Description LOT 4 BLK 2 HIDDEN LAKE PHASE II UNIT I PB24PGS 15T017 Taxes Value Summary 2015 Working Values 2014 Certified Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 59,632 54,049 Depreciated EXFT Value Land Value (Market) 18,000 15,000 Land ValueAg st/Market Value 77 632 69 049 Portability Adj Save Our Homes Adj 13,395 5,322 Amendment 1 Adj Assessed Value 1 $64,237 63,727 Tax Amount without SOH: $648.27 2014Tax Bill Amount $606.25 Tax Estimator Save Our Homes Savings: $42.02 w *Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 64,237 39,237 25,000 Schools 64,237 25,000 39,237 City Sanford 64,237 39,237 25,000 SJWM(Saint Johns Water Management) 64,237 39,237 25,000 County Bonds 64,237 39,237 25,000 Sales Description Date Book Page Amount Qualified Vac/Imp WARRANTY DEED 1/1/1995 02878 1906 64,500 Yes Improved WARRANTY DEED 10/I/1990 02237 1688 67,000 Yes Improved SPECIAL WARRANTY DEED 8/1/1984 01568 1690 100 No Improved SPECIAL WARRANTY DEED 1/1/1984 01533 0598 100 No Improved WARRANTY DEED 10/V1981 01399 1126 46,400 Yes Improved WARRANTY DEED 8/1/1981 01350 0400 45,200 Yes Improved nnu UariPdrdoieadWSwimin unsauoumsion Land Method Frontage Depth Units Units Price Land Value LOT 0 0 1 18,000.00 18,000 httpJAvww.scpafl.org/ParcelDetailinfo.aspx?PID=10203050302000040 1/2 8/17/2015 Florida Building Code Online Business a 1 / . 1 . / NM. Mtof BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map I Links Search 3usines Professi I *,.USER: product Approval Public User Regulation Product Approval Menu > Product or Application Search > Apolication List > Application Detail OFFICE OFTHE FL # FL1956-R11 Application Type Revision Code Version 2014 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Depditm Archived p Product Manufacturer TAMKO Building Products, Inc. Address/Phone/Email PO Box 1404 Joplin, MO 64802 417) 624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 417) 624-6644 Ext 2305 kerri_eden@tamko.com 9 Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By Robert J. M. Nieminen, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard ASTM D3161 ASTM D3462 ASTM D7158 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Year 2009 2009 2008 httpJ/www.floridabLtilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhE43ULv8xAB4z%2bKOdb010tBw%3d%3d 1/4 8/17/2015 Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building Code Online 03/20/2015 04/02/2015 04/06/2015 FL # Model, Number Description or Name 1956.1 Elite Glass -Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.0f Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.0f HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II Glass Seal Elite Glass Seal aop inst.odf used only on roof slopes of 2:12 Verified By: Robert Nieminen 59166 or greater. Nails must be used Created by Independent Third Party: No as the method of attachment. Evaluation Reports Created by Independent Third Party: 1956.2 Glass -Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.pdf HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II Glass Seal Elite Glass Seal app inst.pdf used only on roof slopes of 2:12 Verified By: Robert Nieminen PE 59166 or greater. Nails must be used Created by Independent Third Party: No as the method of attachment. Evaluation Reports Created by Independent Third Party: 1956.3 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.1)df Approved for use outside FL1956 RI1 C CAC UL certification 10-11-12.odf HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II Heritage D F J P aoo inst.odf used only on roof slopes of 2:12 FL1956 R11 II Heritage F aoo inst.odf or greater. Nails must be used FL1956 R11 II Heritage T apt) inst.odf as the method of attachment. Verified By: Robert J. M. Nieminen FL 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.1)df Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.01' HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II heritage 30 aoo inst aoril 10.odf used only on roof slopes of 2:12 FL1956 R11 II heritage 30 aoo inst f aoril 10.1)df or greater. Nails must be used Verified By: Robert Nieminen PE 59166 as the method of attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.5 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.0f HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 RII II heritage 50 aoo inst agril 10.pdf used only on roof slopes of 2:12 FL1956 R11 II heritage 50 aop inst f april 10.pdf or greater. Nails must be used Verified By: Robert Nieminen PE 59166 as the method of attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: httpJ/www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdb01OtBw%3d%3d 2/4 8117/2015 Florida Building Code ONine 1956.6 Heritage Premium A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.Ddf HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be used only on roof slopes of 2:12 or greater. Nails must be used as the method of attachment. FL1956 R11 II Heritage. Premium D P aoo inst.ndf FL1956 R11 II Heritage Premium F aoo inst.pdf FL1956 R11 II Heritage Premium T app inst.pdf Verified By: Robert Nieminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.ndf FL1956 R11 C CAC UL shingle matrix.odfApprovedforuseoutside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II Heritage Vintage app inst.Ddf used only on roof slopes of 2:12 Verified By: Robert ]. M. Nieminen PE 59166 or greater. Nails must be used Created by Independent Third Party: No as the method of attachment. Evaluation Reports Created by Independent Third Party: 1956.8 Heritage Vintage Hip and ridge shingles 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.Ddf FL1956 R11 C CAC UL shingle matrix.odfApprovedforuseoutside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II TAMKOCg) Heritage(g) 12 x 12 Hip and Ridge Application Instructions. pdf Verified By: Robert 1. M. Nieminen PE 59166usedonlyonroofslopesof2:12 or greater. Nails must be used Created by Independent Third Party: No as the method of attachment. Evaluation Reports Created by Independent Third Party: 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.p_df HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II Heritage Woodgate D app inst.odf used only on roof slopes of 2:12 FL1956 R11 II Heritage Woodgate F app inst.pdf or greater. Nails must be used Verified By: Robert Nieminen 59166 as the method of attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.10 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.odf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.odf HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 II heritage A app inst d april Modf used only on roof slopes of 2:12 FL1956 R11 II heritage xl app inst f aoril 10.Pdf or greater. Nails must be used Verified By: Robert Nieminen PE 59166 as the method of attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles Shingles Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R11 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12.i)df http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdb01OtBw%3d%3d 3/4 8/17/2015 Florida Building Code Online HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Hip and Ridge shingles shall be used only on roof slopes of 2:12 or greater. Nails must be used as the method of attachment. Quality Assurance Contract Expiration Date 10/10/2015 Installation Instructions FL1956 R11 II 12.25x12 Hip and Ridge.Ddf FL1956 R11 II 12 x 12 Hip Ridge Application Instructions. Ddf FL1956 R11 II 12-1-4x12 HipRidge Sealant Dab Illustrations.pdf FL1956 R11 II 12x12 HipRidge Sealant Dab Illustrations, odf Verified By: Robert Nieminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: W CreditSAFECard http://www.floridabLildirig.orglpr/pr ppp dtl.aspx?param=wGEVXQwtDgsg/o2fnGFoyT6raQg/o2bp/o2bCXWUhEA3ULv&AB4zp/o2bKOdbOlOtBwp/o3dg/o3d 4/4 Application Instructions for FORMERLY HERITAGE® 30 TAMKO HERITAGE® BUILDING PRODUCTS LAMINATED ASPHA6T SHINGLES Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY. SEE THE LIMITED WARRANTY FOR DETAILS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY, THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER (BELOW 40"F), CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT It is not necessary to remove the plastic strip from the back of the shingles. 1. ROOF DECK These shingles are for application to roof decks consisting of plywood or sheathing boards capable of receiving and retaining fasteners, and to inclines of not less than 2 in. per foot. For roofs having pitches 2 in. per foot to less than 4 in. per foot, refer to special instructions titled Low Slope Application". For roofs having pitches greater than 21 in. per foot, refer to special instructions titled "Mansard Roof or Steep Slope Roof". Shingles must be applied properly. TAMKO assumes no responsibility for leaks or defects resulting from improper application, or failure to properly prepare the surface to be roofed over. NEW ROOF DECK CONSTRUCTION: Roof deck must be smooth, dry and free from warped surfaces. It is recommended that metal drip edges be installed at eaves and rakes. PLYWOOD: All plywood shall be exterior grade as defined by APA - The Engineered Wood Association. Plywood shall be a minimum of 3/8 in. thickness and applied in accordance with the recommendations of APA - The Engineered Wood Association. SHEATHING BOARDS: Boards shall be well -seasoned tongue - and -groove boards and not over 6 in. nominal width. Boards shall be a 1 in. nominal minimum thickness. Boards shall be properly spaced and nailed. 2. VCHTIWITION Inadequate ventilation of attic spaces can cause accumulation of moisture in winter months and a build up of heat in the summer. These conditions can lead to: 1. Vapor Condensation 2. Buckling of shingles due to deck movement. 3. Rotting of wood members. 4. Premature failure of roof. To insure adequate ventilation and circulation of air, the ventilation system must include inlets and outlets. This may be accomplished with a combination of ridge and soffit vents or by using gable end vents. FHA minimum property standards require one square foot of net free ventilation area to each 150 square feet of space to be vented. This may be reduced to one square foot of ventilation area per 300 square feet if at least 40% and not more than 50% of venting is provided not more than 3 feet below the ridge or if a Class I or II vapor barrier is installed on the warm in winter side of the ceiling in climate zones 6, 7, and 8 as recommended by the 2012 International Residential Code. For more information consult your design professional. If the ventilation openings are screened, the total area should be doubled. IT IS PARTICULARLY IMPORTANT TO PROVIDE ADEQUATE VENTILATION, 3. FASTENERS WIND CAUTION: Extreme wind velocities can damage these shingles after application when proper sealing of the shingles does not occur. This can especially be a problem if the shingles are applied in cooler months or in areas on the roof that do not receive direct sunlight. These conditions may impede the sealing of the adhesive strips on the shingles. The inability to seal down may be compounded by prolonged cold weather conditions and/or blowing dust. In these situations, hand sealing of the shingles is required. To insure quicker sealing, apply 4 quarter -sized dabs of TAM -PRO® SBS Flashing Cement, TAMKO or TAM -PRO® Plastic Roof Cement, or TAMKO Tam -Seal Adhesive, meeting ASTM D 4586, Type 1, on the back of the shingle 1 in. (25mm) and 13 in. (330mm) in from each side and 1 in. (25mm) up from the bottom of the shingle. Press shingle firmly into the adhesive. For maximum wind resistance along rakes, install any TAMKO starter shingle including sealant or cement shingles to the underlayment and each other in a 4 in. (102mm) widtKof TAM- PROO SBS Flashing Cement, TAMKO or TAM-PR00 Plastic Roof Cement, or TAMKO Tam -Seal Adhesive. Caution: Apply ONLY a thin uniform layer of adhesive less than 1/8 in. (3mm) thick. Excessive amounts can cause blistering of the shingles and may soften the asphalt in certain underlayments resulting in the asphalt flowing, dripping and staining. Shingles must also be fastened according to the fastening instructions described below. Correct placement of the fasteners is critical to the performance of the shingle. If the fasteners are not placed as shown in the diagram and described below, this will result in the termination of TAMKO's liabilities under the Limited Warranty. TAMKO will not be responsible for damage to shingles caused by winds in excess of the applicable mph as stated in the Limited Warranty. See Limited Warranty on the wrapper or tamko.com for details. FASTENING PATTERNS: Fasteners must be placed 6-1/8 in. from the bottom edge of the shingle, penetrating through the common bond, and located horizontally as follows: 1) Standard Fastening Pattern. (For use on decks with slopes 2 in, per foot to 21 in. per foot.) One fastener 1 in. from each end and one 13-1/2 in. from each end of the shingle for a total of 4 fasteners. See Standard Fastening Pattern illustrated below). STANDARD FASTENING PATTERN FASTENERS NAIL ZONE COMMON BOND 6-1i/8"I I I I I I I I EXPO iLIRE 5-5/8" 12-1/2"—+— 12-3/8" — 12-1/2"-- h-1" Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 D9/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko.com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 1 CONTINUED from page 1) FORMERLY HERITAGE® 30 TAMKO HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS 2) Mansard Fastening Pattern. (For use on decks with slopes greater than 21 in. per foot.) One fastener 1 in. from each end and one fastener 8-1/2 in, from each end and one fastener 16 in. from each end for a total of 6 fasteners per shingle. (See Mansard and High Wind Fastening Pattern illustrated below.) MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN FASTENERS NAIL ZONE COMMON BOND 6-18" EXPOSURE 5-5B" h-i-nu h--irz'-•Ir -ala"-IFS-R"-I-rz"I I-. 3) High Wind Warranty Fastening Pattern. (For High Wind Warranty Application requirements) One fastener 1 in. from each end. One fastener 8-1/2 in. from each end and one fastener 16 in. from each end for a total of six (6) fasteners per shingle. In addition to this shingle fastening pattern requirement for High Wind Application, TAMKO also requires the use of TAMKO starter shingles including sealant strip at eaves and rakes. Alternatively, along rakes, cement shingles to the underlayment and each other in a 4 in. (102 mm) width of TAM -PRO@ SBS Flashing Cement, TAMKO or TAM -PRO® Plastic Roof Cement, orTAMKO Tam -Seal Adhesive. Caution: Apply ONLY a thin uniform layer of adhesive less than 1/8 in. (3mm) thick. Excessive amounts can cause blistering of the shingles and may soften the asphalt in certain underlayments resulting in the asphalt flowing, dripping and staining. High Wind Application is offered on new construction or complete tear -off applications only. It is not offered for recover applications. If High Wind Application requirements are not followed, the High Wind Application Warranty MPH, as stated on Table I in the Limited Warranty, reverts to the Standard Application Wind Warranty MPH limit. (See Mansard and High Wind Fastening Pattern illustrated above.) NAILS: TAMKO recommends the use of nails as the preferred method of application. Standard type roofing nails should be used. Nail shanks should be made of minimum 12 gauge wire, and a minimum head diameter of 3/8 in. Nails should be long enough to penetrate 3/4 in. into the roof deck. Where the deck is less than 3/4 in. thick, the nails should be long enough to penetrate completely through plywood decking and extend at least 1/8 in. through the roof deck. Drive nail head flush with the shingle surface. Property Driven Improporty Driven 3W min diameter undeni&en ovordriven crooked Asphalt shingles Decking I{ 1/4' nominal freight, good penetration, Inadequate too deep, cuts Inadequate end flush with shingle surface penetration Into shingle anchorage STAPLES: If staples are used in the attaching process, follow the above instructions for placement. All staples must be driven with pneumatic staplers. The staple must meet the following minimum dimensional requirements. Staples must be made from a minimum 16 gauge galvanized wire. Crown width must be at least 15/16 in. staple crown width is measured outside the legs). Leg length should be a minimum of 1-1/4 in. for new construction and 1-1/2 in. for reroofing thus allowing a minimum deck penetration of 3/4 in. The Properly Driven Improperly Driven underdnven overdriven crooked eiI Asphalt Shingles Decking h min. crown of the staple must be parallel to the length of the shingle. The staple crown should be driven flush with the shingle surface. Staples that are crooked, underdriven or overdriven are considered improperly applied. CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING PATTERN DIAGRAMS. 4. ONDERIMMENT UNDERLAYMENT. An underlayment must be applied over the entire deck before the installation of TAMKO shingles. Failure to add underlayment can cause premature failure of the shingles which is not covered by TAMKO'S Limited Warranty. Products which are acceptable for use as underlayment are: Asphalt Saturated Felt Underlayments: SuperX 30TM Underlayment TAMKO No. 15 Asphalt Saturated Organic Felt Any TAMKO non -perforated asphalt saturated organic felt A non -perforated asphalt saturated organic felt which meets ASTM: D226, Type I or II or ASTM D4869 Specialty Underlayments: Tam -Shield® Synthetic Underlayment or Synthetic Shield Underlayment TAMKO TW Metal and Tile Underlayment, TW Underlayment and Moisture Guard Plus@ (additional ventilation may be required. Contact TAMKO's Technical Services Department for more information.) A self-adhesive underlayment designed for use with asphalt shingles which meets ASTM D1970. For Asphalt Saturated Felt Underlayments: Apply the felt when the deck is dry. On roof decks with slopes 4 in. per foot and greater apply the felt parallel to the eaves lapping each course of the felt over the lower course at least 2 in. Where ends join, lap the felt 4 in. If left exposed, the felt may be adversely affected by moisture and weathering. Laying of the felt and the shingle application must be done together. For All Other Specialty Underayments: On roof decks with slopes 4 in. per foot and greater apply the underlayment parallel to the eaves in accordance with underlayment written application instructions. The underlayment should not be left exposed for a longer period of time than is specified in the underlayments written application instructions. The final roof covering must be installed before the structure is exposed to adverse weather conditions, such as wind driven rain, high wind, hail, ice storms, etc. (Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko.Com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 2 CONTINUED from page 2) FORMERLY HERITAGE® 30 11 &IMI&V I HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Frederick, MD • Joplin, MO * Phillipsburg, KS In areas where ice builds up along the eaves or a back-up of water from frozen or clogged gutters is a potential problem, TAMKO's Moisture Guard Plus®, TW Metal and Tile Underlayment or TW Underlayment (or any specialty eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent water damage. Contact TAMKO's Technical Services Department for more information. Substitute products as shingle underlayment should not be used. 6. APPLICATION INSTRUCTIONS STARTER COURSE: A starter course may consist of TAMKO Shingle Starter, TAMKO 10-inch Starter or self-sealing 3-tab shingles. If self- sealing 3-tab shingles are used, remove the exposed tab portion and install with the factory applied adhesive adjacent to the eaves. Attach the starter course with approved fasteners along a line parallel to and 1.5 in. to 3 in. above the eaves edge. The starter course should overhang both the eaves and rake edges 1/4 in. to 3/8 in. if drip edge flashing is not used along the eaves or rakes. If drip edge flashing is present, install shingles even with the drip edge. For maximum wind resistance along rakes, Install any Drip edge Rake Fastenors klocated1.12'to 3' tromrekeedge ' Start that strip with 12 Shingle Starter strips overhang Sea-.easng Eave Feztenors D.P edge removed, than follow with tull eaves and rakes AM"- located strips In order Isoffset with the 114" to 3/9. 6 no drip edge positioned 1.12' 1.3' fir. shingle course. gashing o present u drip along eaves from eave edge edge gashing is present. or rake edge instal shingles even with drip edge. SHINGLE APPLICATION: Start the first course with a full size shingle and overhang the rake edge 1/4 in. if drip edge is not present. If drip edge is present, align shingle edge with drip edge flashing. Cut 10-3/8 in. from a full shingle to form a shingle 29 in. long. Use this to start the second course (see diagram below). Cut a 23 in. long shingle to start the third course. Use the remaining 16-3/8 in. piece bare" Y;th repeat 103/8" : ;; _• 4, courses its-3/8° I t E 16-3/8" 23. 5th course 4th course 3rd course 2nd course 1st course t—eave 23" 1B-MI 10-3/8" of shingle to start the fourth course and use the remaining 10-3/8 in. piece to begin the fifth course. Continue up the rake in as many rows as necessary using the same formula as outlined above. The butt of the shingle should be aligned with the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. exposure (see shingle application drawing illustrated on this panel). When you make your final cut at the roof's edge, flip any pieces that are 8 in. or longer back onto the roof. These pieces can be worked in anywhere without creating zippers or color variations. NOTE: Do not align joints of shingle courses when working in cut pieces. Joints should be no closer than 4 in. from one another. Cut your first coun:e shingle to make 29' end a 10 318' length. Cut a second shingle to make a 23' and A 16 3W length. i103B' - \ 1. 17 2.ThBegin spy tafion wdh a tug length shingle. en by your 29', 23'. 16 318' and 10 3/6' lengths, As you can seo, three shingles with two cuts make five courses. _ 3Conume working your way across the mol. When you make your Malcutattherootsedge, fkp any pieces that am 8" or longer back onto the mot. These pieces can be worked in anywhere without creating zippers or color variations. NOTE: Do not align joint. of shingle course. when working in cut places. Joints should be no closer than 4" from one Another. 6. LOW SLOPS APPLICATION On pitches 2 in. per foot to 4 in. per foot cover the deck with two layers of underlayment. Begin by applying the underlayment in a 1/ 2-sheet width along the eaves and overhanging the drip edge by 1/4 to 3/4 in. Place a full -sheet width over the 1/2-sheet width starter piece, completely overlapping it. All succeeding courses will be positioned to overlap the preceding course by 1/2-sheet width. If winter temperatures average 25AF or less, thoroughly cement the laps of the entire underlayment to each other with TAM -PRO or TAMKO Plastic Roof Cement from eaves and rakes to a point of a least 24 in. inside the interior wall line of the building. As an alternative, TAMKO's Moisture Guard Plus®, TW Metal and Tile Underlayment, or TW Underlayment self -adhering underlayment may be used in lieu of the cemented felts. 7. MANSARD ROOF OR STSSP SLOPC ROOF If the slope exceeds 21 in. per foot (60), each shingle must be sealed with TAM -PROD SBS Flashing Cement, TAMKO or TAM -PRO® Plastic Roof Cement, or TAMKO Tam -Seal Adhesive immediately upon installation. Quarter -sized dabs of cement or adhesive must be applied to shingles with a 5-5/8 in. exposure, use 6 fasteners per shingle. See Section 3 for the Mansard Fastening Pattern. Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko. eom Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 3 CONTINUED from page 3) , FORMERLY HERITAGE® 30 I -rhmnu I HERITAGE" BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS 8. RE -ROOFING Before re -roofing, be certain to inspect the roof decks. All plywood shall meet the requirements listed in Section 1. It is not recommended to install laminated asphalt shingles directly over existing laminated shingles due to the unevenness of the existing multi -layered shingles. The performance of the sealant feature may be compromised, preventing the shingles from sealing properly. It is acceptable to install laminated shingles over existing three -tab strip shingles which are flat and essentially intact. Nail down or remove curled or broken shingles from the existing roof. Replace all missing shingles with new ones to provide a smooth base. Shingles that are buckled usually indicate warped decking or protruding nails. Hammer down all protruding nails or remove them and refasten in a new location. Remove all drip edge metal and replace with new. If re -roofing over an existing roof where new flashing is required to protect against ice dams (freeze/thaw cycle of water and/or the backup of water in frozen or clogged gutters), remove the old roofing to a point at least 24 in. beyond the interiorwall line and apply TAMKO's Moisture Guard Plus®, TW Metal and Tile Underlayment, or TW Underayment. Contact TAMKO's Technical Services Department for more information. Measurements will vary when nesting over an existing 5 in. exposure single roof: Call TAMKO Technical Services for further information. The nesting procedure described below is the preferred method for reroofing over existing metric size shingles with a 5-5/8 in. exposure. See description below: Starter Course: Remove the tabs and an additional portion from the head of a full size shingle so that its height is equal to the exposure of the existing shingles. Position the resulting strip over the existing roof edge (with the factory -applied adhesive strip along the eaves). Cut approximately 6 in. from the rake end and apply the remaining portion at the eaves. Continue the starter strip by applying full length shingle strips cut to height as above, evenly along the existing roof at the eaves. The existing roof should overhang the eaves far enough to carry water off into the gutter. If this is not the case, cut and apply the starter strip so that it will provide sufficient overhang for proper drainage. Dnp First Course: Remove an amount from the butt edge of afull-size shingle so that the remaining portion of the shingle fits between the butts of the existing third course. This course must also be applied evenly along the eaves edge of the new starter strip. Second and Succeeding Courses: Remove 10-3/8 in. from the rake end of the first shingle in the second course, and continue with full width shingles for the remainder of the course, placing the top edge of each new shingle against the butt edge of the old shingle in the course above. This method should create an exposure of 5-5/8 in. after the first course. When beginning the succeeding courses continue to follow the Heritage application instructions. (See section 5). 8. VALLEY APPLICATION Overthe shingle underlayment, center a minimum 36 in. wide sheet of Moisture Guard Plus®, TW Metal & Tile Underlayment, or a minimum 50 lb. roll roofing in the valley. Nail the underlayment only where necessary to hold it in place and then only nail the outside edges. IMPORTANT: PRIOR TO INSTALLATION WARM SHINGLES TO PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING SHINGLES TO FORM VALLEY. After valley flashing is in place: Apply the first course of shingles along the eaves of one of the intersecting roof planes and across the valley. Note: For proper flow of water over the trimmed shingle, always start applying the shingles on the roof plane that has the lower slope or less height. Extend the end shingle at least 12 in. onto the adjoining roof. Apply succeeding courses in the same manner, extending them across the valley and onto the adjoining roof. Press the shingles tightly into the valley. Use normal shingle fastening methods. Note: No fastener should be within 6 in. of the valley centerline, and two fasteners should be placed at the end of each shingle crossing the valley. To the adjoining roof plane, apply one row of shingles vertically facing the valley and 2 in, back from the valley centerline. Note: For a neater installation, snap a chalkline over the shingles for guidance. To complete the valley, apply shingles on the adjoining roof plane by positioning the tip of the first shingle of each row at the 2 in. point from the centerline where the edge of the vertical shingle has been applied, covering the vertical shingle. Minimum 36" wide sheet of Moisture Guard Plus, TW Metal & Tile orheavle Underfayment Valleycenterline t Extra nail in Place up or shingle on toe eoge or the vertical shingle, 2 Inches back from valley centerline and covering the vertical shingle. Extend end shingle 12"- 16"beyond vdley centerline No fasteners within 6" of centerline FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800- 641-4691. Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko. com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 4 CONTINUED from page 4) FORMERLY HERITAGE® 30 1 IL &&1R1&iU.. HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS 10. HIP AND RIDGE FASTENING DCTAII, Apply the shingles with a 5-1/8 in. exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing winds. Secure each shingle with one fastener on each side, 5-5/8 in. back from the exposed end and 1 in. up from the edge. TAMKO recommends the use of TAMKO Hip & Ridge shingle products. Where matching colors are available, it is acceptable to use TAMKO's Elite Glass -Seal shingles cut down to 12 in. pieces. Fasteners should be 1/4 in. longer than the one used for shingles IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING SHINGLE IN COLD WEATHER. Direction prevailing wind THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY. SEE THE LIMITED WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800-641-4691. Information Included in these application Instructions was current at time of printing. To obtain a copy of the most current version of these application Instructions, visit us online at tamko.com or call us at 800-641-4691. TAMKO®, Moisture Guard Plus®, Tam -Shield®, TAM -PROS and Heritage® are registered trademarks and SuperX 30 is a trademark of TAMKO Building Products, Inc. Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 tamko.Com Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 5 JP69909 I jr CITY OF SANFORD BUILDING SERVICES Residential Re -Roof Hurricane Mitigation Inspection Affidavit Permit #: 1_. ' 2'1(e (y I, J. Douglas Lanier hereby acknowledge that I •personally inspected Roof deck nailing and/or Secondary water barrier work at 207 Borada Road, Sanford, FL. 32773 and have determined that the work Job Site Address) was done according to the Hurricane Mitigation Retrofit Manual. (based on 553.844 F.S.) I certify that my statements herein are true and accurate to the best of my belief and that I fully understand that making any false statements in writing with the intent to mislead a public servant in the performance of his or her official duty shall constitute a misdemeanor of the second degree pursuant to Section 837 6F.S. Signature o Contractor Date J. Douglas Lanier Printed Name of Contractor CCC058022 License # License Type: General Building D Residential 29 Roofing Contractor or any individual certified in accordance with F.S. 468 to make such an inspection. STATE OF FLORIDA COUNTY OF Seminole A6) tSwornto ( r • firme ) and subscribed before me this day of 20 15 , by J. Dougl ier who is Persona Known to me or has 0 Produced (type of identi as identification. SEAL) Signs a of 6D6ry Afilic State of Florida Stephanie J. Williams Print/Type/Stamp Name of Notary Public STEPHANIE JOY WILLIAMS MY COMMISSION #EE847705oQ 7,' oQ•' OF F<. EXPIRES October 29, 2016 407) 398-0153 FloridaNOtaryService.com