HomeMy WebLinkAbout2592 River Landing DrC JUL 0 a 26i D BY: - OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: ' Documented Construction Value: $ 2350.00 Job Address: 2592 River Landing Drive Historic District: Yes No [3 Parcel ID: 26-19-30-5SY-0000-0920 Zoning: Description of Work: screen room with 3" Elite panel roof on existing slab Plan Review Contact Person: Don Geissler Title: President Phone: 407 461-9929 Fag: 407 365-3194 E-mail: sunstatesiding@aol.com Property Owner Information Name Ruth Florman Phone: 720 870-5427 Street: 5601 S. Sicily Circle Resident of property? : yes City, State Zip: Aurora, CO 80015 Contractor Information Name Sun State Siding, Inc Phone: 407 830-7778 Street. 510 Lake Lenelle Drive Fag: 407 365-3194 City, State Zip: Chuluota, FL 32766 State License No.: SCCO48423 Architect/Engineer Information Name: Aluminum Screen Design Michael Thompson Phone: 407 529-3300 Street: 5200 Vineland Road, #250 Fax: 888 923-8181 City, St, Zip: Orlando, FL 32811 E-mail: Bonding Company: Mortgage Lender: Address: Address: PERMIT INFORMATION Building Permit Square Footage: Construction Type: No. of Stories: No. of Dwelling Units: Flood Zone: Electrical Plumbing New Service — No. of AMPS: New Construction - No. of Fixtures: Mechanical (Duct layout required for new systems) Fire Sprinkler/Alarm No. of heads: 0) J Shall be inscribed with the date of application and the code in effect as of that date (Code 2010 FBC) 731.135(5)(6) Florida Statutes. REV 07.14 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Date kazyf L_,:%,0 zV ,"Z L. Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID. _ APPROVALS: ZONING: :Z—%- TILITIES: ENGINEERING: FIRE: A 0 1-4, ._ )_ 1,-iL-15 Signature of Contractor/Agent Date 2 of Notary -State pfF fc's Nblaly Public - State of Florida My Comm. Expires Jul 9, 2016 nde?e Commission #r EE 192806 l,.. Bonded Through National Notary Assn. Contractor/Agent is / Personally Known to Me or Produced ID _,'Type of ID WASTE WATER: BUILDING- T 159, i COMMENTS: ck 4, 1 rey>„ (-can,,., w, -4t, 3-) le Cif Sb b o s Sho.4n or, fbvl. I Sc >., ee-y_J _,.L e 6e, `Cgnn5+cLc+e5 AeS%-,a,,, nx,4erm) sfy + +h n..6r 1 0.d; cpr Shall be inscribed with the date of application and the code in effect as of that date (Code 2010 FBC) 731.135(5)(6) Florida Statutes. REV 07.14 n,n ex;SiI Revision Response to Comments Permit # 5- 2:2-8 City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 1 F,mM buildin nfordfl.gov JUL 2 8 2015 Submittal Date Y: Project Address: 2'592- R tVCr Contact: -D:5h Ph: 'Av-1 L\c.e - 00k 2Cfl Email:1 cVir'( o' O D`•CdY, Trades encompassed in revision: Fax: 401 General description of revision: Building ) YCViSCc` Q1 S Plumbing Electrical 2 CurrCyl - fLg Mechanical •' 'v Life Safety Waste Water ROUTING INFORMATION Approvals A'*re- . Bio, fg Department Utilities Waste Water Planning Engineering Fire Prevention 0 Building ROUTING INFORMATION Approvals A'*re- . Bio, fg CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION 300 N. PARK AVENUE SANFORD,, FLORIDA 32772 PHONE: 407.688.5150 FAx: 407.688.5152 PLAN REVIEW COMMENTS Application Number: 15-2283 Date: July 14, 2015 Contact Person: Don Geissler Contact Fax Number: Contact E-mail Address: sunstatesiding(i aol.com Project Description: Screen Room Job Address: 2592 River Landing Dr The following is a list of the areas of the submitted plans that contained violations of the codes adopted by the City of Sanford and enforced by the Building Division. The violations noted must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal. Changes to construction documents that require an Architect or Engineer's seal must be submitted with the appropriate seal. Provide two copies of affected plan sheets and/or supplemental information as requested. COMMENTS: 1. The plans have been designed under the incorrect building code. The current building code, as of June 30, 2015, is the 5t' Edition 2014 Florida Building Code. Please revise the plans to indicate compliance with the current building codes. Any plans submitted on or after June 30, 2015 are required to be in compliance with the new 5' edition of the Florida Building Code. FBC 107 2. The Florida Product Approval must be approved under the 2014 Florida Building Code. FBC 107 No plan review has been conducted. Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Please direct any questions you may have to Steve Fiorey at 407-688-5065 or by E-mail at steve.fiorey@sanfordfl.gov . Respectfully, Steve Fiorey Residential Plans Examiner 1- SUN STATE SIDING, INC. 510 LAKE LENELLE DRIVE CHULUOTA, FL 32766 407 830-7778 phone 407 365-3194 fax Submitted to: Ruth Florman 5601 S. Sicily Circle Aurora, CO 80015 rf82859(cDvahoo.com 720 870-5427 PROPOSAL State License SCC048423 R-E-CED JUL 0 8 NIS BY: PROPOSAL# 1 DATE 6/03/2015 Job Location: 2592 River Landing Drive Sanford, FL 32771 RV Lot 92 We propose to fumish all the materials and perform all the labor necessary for the completion of: Furnish and install screen room on existing slab with 3" Elite panel roof $ 2,350.00 with 12" overhang, extruded drip edge fascia, 14' of 6" gutter and (1) 3 x 4 downspout, 1) 3' 0" x 6' 8" screen door, 18 x 14 charcoal screen, finish caulk. Chair rail height 36" Price includes site specific, engineer stamped plans & City of Sanford permit All material is guaranteed to be as specified and the above work to be performed in accordance with the drawings and specifications submitted for the above work and completed in a substantial workmanlike manner for the sum of: $ 2,350.00 With payments to be made as follows: FULL PAYMENT UPON COMPLETION (We accept cash or check only) Any alteration or deviation from the above specifications involving extra cost will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry fire, tomado, and other necessary insurance upon the above work. Workman's Compensation and Public Liability insurance on above work to be taken out by Sun State Siding, Inc. THERE WILL BE A $50.00 BOOKKEEPING CHARGE IF THE INVOICE IS NOT PAID IN 30 DAYS. Submitted by DONALD G. GEISSLER, JR., PRESIDENT This proposal may be withdrawn by us if not accepted within 60 days. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to perform the work specified. Payment will be made as outlined above. ffwo Printed Name • kuru E—Lcig-t-ytmy RMCM IrELIP JUL 0 S 2015 BY.-- - City of Sanford Aluminum Structures Permit Application Checklist All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. 6a' Copy of a contract, signed by the contractor and the property owner, indicating the documented construction value of the project. 0 Copy of applicable contractor's license issued by the State of Florida. 1Z A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. D/ Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). Completed and Signed Owner Builder Statement / Affidavit (if the owner is the applicant). S1 Two (2) site plans indicating proposed location. Two (2) copies of the signed and sealed engineered drawings. blind design data required on drawings per FBC 1603.1.4 to meet 129 mph ultimate design wind speed for risk category I buildings OR Two (2) copies of previously mastered filed plans. Indicate all details and options that apply. Two (2) copies of a site specific layout for the structure with minimum 1/8" per foot scale. Include all framing sizes and Types. Include any electrical devices to be added. f Two (2) copies of Florida Product Approval, including manufacturer installation instructions and product evaluation reports, for composite or elite roofing systems. (If applicable) For Sunrooms — must designate specific Sunroom Category on the signed and sealed plans, in accordance with FBCR R301.2.1.1.2 These guidelines were compiled to assist the applicant in preparing an aluminum structure permit application and may not be complete. The applicant is required to meet all City of Sanford, state, and federal code requirements. Revised: February 2015 Y Plan Types:: Screen Room Pool Screen/Cage Car Port REVIEWED FOR CODE COMFLIANCE Patio Cover — PLANS EXAMINER Other: '1'4 -( -- DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Reference:. New7 Revision Date: 6/22/15 Project Address: 2592 River Landing Drive City: Sanford, FL 32771, - Contractor Name: Sun State Siding, Inc Address: 510 Lake Lenelle Drive # 15 2 2 8 3 City: Chuluota, FL Zip Code: 32766 SANFORD Phone/Fax: 407 830-7778 ofc/407 461-9926 cell/407 365-3194 fax °FPAR Email: sunstatesiding@aol.com Choose One: Mail ZPick Up Fed Ex* 2 No of Copies For FedEx option go to sticvw.aluminumscreendesign.com and provide FedEx account #) Payments Check Credit Card'" or Credit Card option go to ww.aluminumscreendesign.com to pay by credit card) Engineering prepared by: Engineer: Michael Thompson, MSc, P.E. (P.E. # 47509) 5200 Vineland Road- Suite 250 Orlando, FL 32811 Off 407-529-3300 Cell 407-721-2292 Project Manager. Paul Thomas 386-479-9504 Fax 888-923-8181 Email: aluminumscreendesignn(&yahoo.com Website: www.aluminumscreendesi nqcomCA#30930 ALUMINUM SCREEN DESIGN END 00 A 5 Aluminum & Gonstructi•on Engineering Ultimate Wind Speed (mphj: 130 Exposed Category: C Risk Category Screen Room: Insulated 0 Pan Roof Fascia 21 Wall: Block Conventional Uprights 2 Xs Top Plate 2 X2 Kick Plate Pool Screen/Cage Dome Gable Mansard Gutter Wall: Block Conventional Beams X Uprights X Purlin X Car Port: Insulated Pan Fascia Wall: Block Conventional Beams X Post X Patio Cover: Insulated Pan Fascia Wall: Block Conventional Beams X Post- X 1 Concrete: Existing 0 New: 4"Slag Pier Ribbon Footer X Pavers Other: Note: In the event that there is a conflict with the design plans and the general notes and design standard, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and the general notes and design standard. ONASDALUMINUM SCREEN DESIGN Aiumlis ru is c_- az Pu&afia Lnerm--sink General Notes & Design Standards Screen Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Desien Codes: Florida Building Code 2014 (51 Edition) Aluminum Design Manual 2010 ASCE 7-10 Desien Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -130 MPH (FBC Table 2002.4) Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements: Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310 www.aluminumscreendesign.com Zo AIUM# £)'M SCREEN DESIGN Llsitnit.;let s trcielien Engti`ru-drirl Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum design. All aluminum shall be 6005-T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B18.6.4 specification. Self—tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro -galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Chair Rails, Purlins & Wind Brace: Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction. Wind Speed =130 MPH 2 x 2 Chair Rail = 6'-9" 2 x 2 Purlins = 7'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 10'-0" 2 x 3 Chair Rail = 9'-0" 2 x 3 Purlins = 9'-0" 2 x 3 Wind Brace = 9'-0" 2 x 4 Wind Brace = 10'-0" Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be'/4" Reinforcine Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A185 Welded Wire Fabric shall be ASTM Al 85 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Hole Alienment: Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips and foreign matter between contacting 'surfaces shall be removed before assembly. 5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310 www.aluminumscreendesign.com AILIMINUM SCREEN DESIGN MAS Dmu; rCt4. M X. La zttust[tt Eag2r.^Ing Beams & Uprights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 130 MPH PRIMARY BEAMS & COLUMNS -SCREEN & PATIO ROOM ENCLOSURES ROOF,PANELS Max Beam Span & Max Column Insulated Roof Beam -Size Spacing Column -Size Max Column -Height Pan Roof Span Span 3' - 3" Spans 13'- 2X3 2X3 61-01 1 2 X 3 8'-0" 6" 3" Spans 15'-0" 6" Spans 20'-0" 2 X 4 8'-6" 2 X 4 8'-0" 2 X 5 10'-0" 2 X 5 9'-0" Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Purlin• Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall not exceed 7'-2". 5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310 www.aluminumscreendesign.com R I V a -IAV 1, eW' Lt;,- rA SUN STATE"SIDING;INC. y, " 51.0 LAKE LENELLE DRIVE CHULUOTA, FL 32766--"" DONALD,G. GEISSLER„JR. c -v, SCC048423 V( 407 830-7778 PHONE/407 365-31 FAX _ f scs Co r>z vIL 3'Llrt PAPfL P7MU To FY IA y ' A; Z F iR I z" o. H.(-ryF) F90rar WAIL. SIVE , A*us E1.c 5r cry:, i. UP—11 zxz PooR i,ocg7 NNY UA Ry D4155 "tt.o-r ArmT $Y" xz Xz I'l zxz w TRS rt 0 x,rr %tom we' 5tflw-*E ALUMINUM SCREEN DESIGN. EXTRUDED FASCIA IS ATTACHED TO 3" C CHANNEL IS ATTACHED THRU FASCIA INTO RAFTER TAMS WITH 910 2" 6" FROM 3" INSULATED ROOF WITH #10 1" 6" ENDS 24" O.C. & TO 3" INSULATED ROOF WITH (6) 910 V PER SIDE FROM ENDS 24" O.C. EXTRUDED GUTTER IS ATTACHED 3" INSULATED ROOF WITH #10 1" 6" FROM ENDS 24" O.C. ROOF IS ATTACHED TO FRONT WALL WITH (4) 910 4" PER PANEL , 2X3 FRONT WALL TOP PLATE 2X2 POST .046 OR GREATER HINGE LOCATIONS I SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL 0" to 36" 2 HINGE DOOR L EACH DOOR IS SCREWED INTO UPRIGHTS WITH 410 1" 6" FROM ENDS 24" O.0 KICK PLATE IS ATTACHED TO STRUCTURE WITH #10 1" 6" FROM ENDS 18" O.C. ALUM]NUMSCREENDESIGN.COM ALUMINUMS CREENDE S IGN UPRIGHTS ARE ATTACHED WITH: BLIND SCREWED WITH (3) 910 3", CAPRI CLIPPED WITH (4) #10 1" PER CLIP BLIND CLIPPED WITH (4) #10 1" PER CLIP 1X2 IS ATTACHED TO FRONT WALL WITH #10 2" 6" FROM ENDS 24" O.C. CHAIR RAIL IS ATTACHED TO UPRIGHTS WITH EITHER: BLIND SCREWED WITH (3) #10 3", CAPRI CLIPPED WITH (4) #10 1" PER CLIP BLIND CLIPPED WITH (4) #10 1" PER CLIP UPRIGHTS ARE ATTACHED WITH: BLIND SCREWED WITH (3) #10 2", CAPRI CLIPPED WITH (4) #10 1" PER CLIP T TA !nr TnnT T% rr7TTLT /A\ 441 A 1 ff DUD OT TD DESIGN STATEMENT METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" EMBEDMENT DEPTH INSULATED ROOF IS ATTACHED TO JLUMINUM STRUCTURE WITH #10 4" FROM ENDS 24" O.C. SIDE WALL TOP PLATE 1X2 IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS 6" FROM ENDS 24" O.C. 2X4 SIDE WALL UPRIGHTS 2X2 CHAIR RAIL 1X2 IS ATTACHED TO CONCRETE WITH 2-1/4" X 1/4" TAPCONS 5" X 1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. @YAHOO.COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) PHONE #: 386-320-0256 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 130 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 101.4 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK C FAX #: 888-923-8181 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS MICHAEL THOMPSON 5200 VINELAND RD. SUITE 250 FL32811 E.' # 47509 CA#30930, ALUMINUM SCREEN DESIGNEXTRUDED FASCIA IS ATTACHED TO 3" C CHANNEL IS ATTACHED THRU FASCIA INTO RAFTER TAILS WITH #10 2" 6- FROM 3" INSULATED ROOF WITH #10 1" 6" ENDS 24. O.C. & TO 3- INSULATEDROOF WITH (6) #101- PER SIDE FROM ENDS 24" O.C. EXTRUDED GUTTER IS ATTACHED 3" INSULATED ROOF WITH #10 1" 6" FROM ENDS 24" O.C. ROOF IS ATTACHED TO FRONT WALL WITH (4) #10 4" PER PANEL , 2X3 FRONT WALL TOP PLATE 2X2 POST .046 OR GREATER HINGE LOCATIONS SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL 0" to 36" 2 HINGE DOOR EACH DOOR IS SCREWED INTO UPRIGHTS WITH 910 1" 6" FROM ENDS 24" O.0 KICK PLATE IS ATTACHED TO STRUCTURE WITH #10 1" 6" FROM ENDS 18" O.C. UPRIGHTS ARE ATTACHED WITH: BLIND SCREWED WITH (3) #10 3", CAPRI CLIPPED WITH (4) #10 1" PER CLIP BLIND CLIPPED WITH (4) #10 1" PER CLIP 1X2 IS ATTACHED TO FRONT WALL WITH #10 2" 6" FROM ENDS 24" O.C. CHAIR RAIL IS ATTACHED TO UPRIGHTS WITH EITHER: BLIND SCREWED WITH (3) #10 3", CAPRI CLIPPED WITH (4) #10 1" PER CLIP BLIND CLIPPED WITH (4) 910 1" PER CLIP UPRIGHTS ARE ATTACHED WITH: BLIND SCREWED WITH (3) #10 2", CAPRI CLIPPED WITH (4) #10 1" PER CLIP BLIND CLIPPED WITH (4) #10 1" PER CLIP INSULATED ROOF IS ATTACHED TO JLUMINUM STRUCTURE WITH #10 4" FROM ENDS 24" O.C. SIDE WALL TOP PLATE 1X2 IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS 6" FROM ENDS 24" O.C. 2X4 SIDE WALL 2X2 CHAIR RAIL 1X2 IS ATTACHED TO CONCRETE WITH 2-1/4" X 1/4" TAPCONS 5" X 1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. ALUMINUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 5200 VINELAND RD. ALUMINUMSCREENDESIGN ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" EMBEDMENT DEPTH SUITE 250 @YAHOO•COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION PHONE # : 386-320-0256 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND O O; FL. 32811 SPEEDS OF 130 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 101.4 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. # 47509 FAX #: 8 88-923 -8181 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION' CONTRACTOR SHALL NOTIFY THE ENGINEER RvRAEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS ,?CA#3 093 0. ALUMINUM SCREEN DESIGN. 2 HINGE 2X2 POST .046 OR GREATER HINGE LOCATIONS SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O. FILL IN DETAIL BOTTOM PLATE IS ATTACHED TO OCONCRETE WITH 2-1/4" X 1/4" TAPCON 5" X 2-1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. ALUMINUM FRAME IS ATTACHED TO BLOCK WITH 2-1/4" X 1/4" 10 2" IF TO WOOD STRUCTURE) 6" FROM ENDS 24" O.C. 2X2 ANGLE IS ATTACHED TO ALUNIINUM FRAME WITH 2 #10 1" 12-1/4" X 1/4" TAPCON PER SIDE CHAIR RAIL & UPRIGHTS ARE ATTACHED WITH EITHER: O BLIND SCREWED WITH (3) #10 3", CAPRI CLIPPED WITH (4) 910 1" PER CLIP BLIND CLIPPED WITH (4) #10 1" PER CLIP O KICK PLATE IS ATTACHED TO STRUCTURE WITH #10 1" 6" FROM ENDS 18" O.C. ALUNIINUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 5200 VINELAND RD. ALSCREENDESIGN ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" EMBEDMENT DEPTH -SUITE 250 @Q iIT AHOO • COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) Q ,' O FL 32811 PHONE #: 386-320-0256 SPEEDS OF 130 NTH THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND PH (FOR 3 SECOND GUSTS) NOMINAL SPEED 101.4 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1 E. # 47509 FAX #: 888-923-8181 C CONTRACTOR SHALLNOTIFY THE ENGINEER MMEDIATELY SHOULD SITE CONDITIONS DIFFIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, ERFROM CONRICATION STRUCTION PLANS 9CA#30930, I';Florida;Ruilding Code Online F Be si ess t fe si a al= ions , Pi011(id(Je klttMe€ltd BCIS Home Log In User Registration Hot Topics 31usines+/'l Product ApprovalProfessignalUSER: Public User Regulation https://floridabuilding.orgfpr/pr app_dtl.aspx?param=wGEVXQwtDq... Submit Surcharge Stats & Facts Publications FBC Staff SCIS Site Map Links Search ProduApproval Menu > Product or Aoolkatlon search > AooEcation Lst > Application Detail FL # FL5500-R4 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Elite Aluminum Corporation Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 954)949-3200 dk@doldmengineering.net Authorized Signature Frank Bennardo frank@engexp.com Technical Representative Bruce Peacock Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 954)949-3200 bpeacock@elltealuminum.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Frank L. Bennardo, P.E. the Evaluation Report Florida License PE -0046549 Quality Assurance Entity Quality Auditing Institute Ltd. Quality Assurance Contract Expiration Date 12/31/2018 Validated By Jorge A. Pomerantz, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL5500 114 COI Indep.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL5500 R4 Equiv Eguiv.pdf 1 of 2 7/14/2015 12:09 PD i FloridaoBuilding Code Online https:Hfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDq... Sections from the Code 104.11.2 1709.3 Product Approval Method Method 2 Option B Date Submitted 02/26/2015 Date Validated 03/08/2015 Date Pending FBC Approval 03/09/2015 Date Approved 04/15/2015 Summary of Products FL # i. Model, Number or Name Description 5500.1 - Aluminum / Aluminum Roof Panels ` EPS Foam Core Composite Patio Roof Panels 1 Limits of Use Installation Instructions I Approved for use in HVHZ: No FL5500 R4 II DWD.Ddf i Approved for use outside HVHZ: Yes i Verified By: Frank L. Bennardo, P.E. PE0046549 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: For outdoor patio construction only. For use outside FL5500 R4 AE Eval.pdf the HVHZ. See installation drawing for allowable span/load FL5500 R4 AE NOA 11092607.Ddf combinations. FL5500 R4 AE Test Reports i.pdf FL5500 R4 AE Test Reports 2.pdf I Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street Talahe«ee FL 32399 2hOne, BSO -487-1824 The State of Florida is an WEED employer. ropyrhht 2007-2013 state of Florida.:: a*vaCy Statem:: Accessb By Statement :: Refund Statement Under Florida law, email addresses are pubic records. ifyou do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. instead, contact the office try phone or by traditional mail If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emads provided maybe used for official communication with the licensee. However email addresses are public record. ff you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine Yyou area licensee under Chapter 455, F.S., please tick hem. Product Approval Accepts: F 9:MN ---x 0 ltiurktrml TrttCism 2 of 2 7/14/2015 12:08 PI EPS FOAM CORE ROOF PANELS ALUMINUM / ALUMINUM SKIN MAYTIAl IM AI I.nWABLE CLEAR SPAN TABLES: CLEAR SPAN TABLE USE INSTRUCTIONS: 1. DETERMINE TYPE OF ENCLOSURE TO BE COVERED (OPEN, SCREENED WALLS, OR FULLY ENCLOSED). 2. DETERMINE THE SITE SPECIFIC REQUIRED DESIGN WIND PRESSURE PROVIDED BY SEPARATE ENGINEERING, BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, IN ACCORDANCE WITH THE FLORIDA BUILDING CODE FIFTH EDITION (2014). 3. FIND ALLOWABLE COMPOSITE PANEL CLEAR SPAN IN TABLES FOR APPROPRIATE PANEL DEPTH, FACING THICKNESS, AND EPS CORE DENSITY SELECTED. SEALJOINT CONTINUOUS CAULKING CROSS SECTION AT 7YPICATi7fNECf FTERCOCK EPS ROOF PANEL SPAN DETAIL: 0.024' OR 0.032" ALUM I W MAX WIDTH PER INTERLOCKING PANEL TOP &BOTTOM FACINGS 1/4" PER FOOT t41N SLOPE) CLEAR SPAN (L) INSIDE TO INSIDE - REFER TO ADDI ALNEERING SHEETSFORLOADS, ROONS, & SUPPORTINGSTRUCTUREDETERS). THIS SHEETCERTIFIESALOFSPANSONLY. DEFLECTION NOTES: __ r MAXIMUM ALLOWABLE DESIGN PRESSURES: AS NOTED IN CLEAR k4T TESPANTABLES 3"Pnncls 4"Panels G"Pnrwls Live load Dokcllon 0.024" 0.032" 0.024• t 0.032" 0.024- i 0.032" Ww Uplift; Limit Num Skin Alum Skin Alun Skin' Num Skin Alum Skin l Alum Skkl U 0 t m 1) 14b EPS 1•Ib EPS 1.81 EPS 1•ib EPS 1 -@EPS I1•Ib EPS PS' L112D 14'•0" 16'-3" f0'4r 15-0` 23•2 23'•0' 12 Pa L 11 20 13'-2" 16•3" tri 12' tr-H" 2r•9" 2Z -S' 14 Psf LI120 12'.r 14'-G" IT -t" it -0" 20'-8" I 21'J" 1 10 PSI I L1120 11'-12" 13'-10" IG*4" 10'•3" 10'-/D" S 20'-0" IB PSI20PSI I Ll 120 L1120 11'•6' 11'•2' iT-4" 12'-10" 15'•8" 15.0" 15'"2 15.1" 10'•0" 10'•7" 10'-4" ! 10'•11" 24 psf LI 120 10'•6" 12'•1" 14'•3" 14'•3" 1r-3" 1 Ir S' 26 psf L 11 20 0'•11' 11'•6" 10'-fi 13'•6" 1G-5' 10'•2" 32 PSI LI 120 0'-3" 11'-0" 12'•8" IS'"5" 15'•1' CLEAR SPAN TABLE USE INSTRUCTIONS: 1. DETERMINE TYPE OF ENCLOSURE TO BE COVERED (OPEN, SCREENED WALLS, OR FULLY ENCLOSED). 2. DETERMINE THE SITE SPECIFIC REQUIRED DESIGN WIND PRESSURE PROVIDED BY SEPARATE ENGINEERING, BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, IN ACCORDANCE WITH THE FLORIDA BUILDING CODE FIFTH EDITION (2014). 3. FIND ALLOWABLE COMPOSITE PANEL CLEAR SPAN IN TABLES FOR APPROPRIATE PANEL DEPTH, FACING THICKNESS, AND EPS CORE DENSITY SELECTED. SEALJOINT CONTINUOUS CAULKING CROSS SECTION AT 7YPICATi7fNECf FTERCOCK EPS ROOF PANEL SPAN DETAIL: 0.024' OR 0.032" ALUM I W MAX WIDTH PER INTERLOCKING PANEL TOP &BOTTOM FACINGS 1/4" PER FOOT t41N SLOPE) CLEAR SPAN (L) INSIDE TO INSIDE - REFER TO ADDI ALNEERING SHEETSFORLOADS, ROONS, & SUPPORTINGSTRUCTUREDETERS). THIS SHEETCERTIFIESALOFSPANSONLY. DEFLECTION NOTES: __ r MAXIMUM ALLOWABLE DESIGN PRESSURES: AS NOTED IN CLEAR k4T TESPANTABLES DESIGN NOTES: POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED BY OTHERS ON A ]OB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE-SPECIFIC PRESSURE AND CI AITTERE1609TOF THES AS EFLORIDA BVILD NG CODE IFTH EIT ONERMINEDINACCORDANEWIT. ASCE W W I i- W W J •., O 7 u' 'y, V 1 2014) SI IALL BE LESS THAN OR EQUALTO THE POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY Z IInn L U F, w ' Q 2ASSHOWN. U 0 t m 1) GENERAL NOTES: ZX iVp w 1. THIS SPCCIFiCATION HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA w W w 3 ds • ;- BUILDING CODE FIFTH EDITION (2014) FOR USE OUTSIDE THE HVI IZ. t E ROOF SECTION0, nER Er R . CLASS A INTERIOR FINISH, AND CHAPTERI2GrHnSECTION803 N° p 2. NO 33.1/3% INt THE DESIGN OF THIS 3. THE ARCHITECT SUPERSTRUCTURE WI RESPONSIBLE FORTH THIS DESIGN WHICH CONTRACTOR. 4. SEPARATE 'SITE REQUIRED IN ORDER CONTAINED HEREIN. TABLES LISTED HERE ENGINEER FOR ALTEF S. THE SYSTEM DT 1, USE L/120 FOR ALL MEMBERS SUPPORTING ROOFS OVER AN OPEN OR SCREEN -WALLED T 2. USE L/180 FOR ALL MEMBERS SUPPORTING ROOTS VITA A NON -PLASTERED CEILING OVER F/ AN ENCLOSED ROOM. S. 3. USE L/240 FOR ALL MEMBERS SUPPORTING ROOFS WITH A PLASTERED CEILING OVER AN M ENCLOSED ROOM, PER FLORIDA BUILDING CODE FIFTH EDITION (2014) TABLE 1604.3. A; OTHER CONSIDERATIONS' 1. FRONT OVERHANG MAY BE UP TO 3'-0" WITH VALUES LISTED HEREIN. MAXIMUMUNSUPPORTEDSIDEOVERHANGIS2S% OF LAST PA14EL WIDTH (Lo. 12" MAX FOR 48" PANEL WIDTH). 2. ROOF PITCH SHALL BE AS PER BUILDING CODE RE UIREMENT5 PANEL OPTIONAL GUTTER OR DRIP CAP 36" MAX O/H AT FRONT & 25% OF LAST PANEL WIDTH AT SIDES UP TO 12" MAX O/H AT SIDES) r_UI IN ALLOWABLE STRESS HAS BEEN USED IN SEALED kyr TABLE VALUE DERIVATIONS: TERING SHALL BE DEFLECTIONS, OR SPANS F THE ALLOWABLE SPAN D, CONTACT THIS AS MAY BE REQUIRED. C AND DOES NOT PROVIDE CONDITIONS DIFFERENT ENSCD ENGINEER OR PECIFIC DOCUMENTS FOR IDER POSSIBLE IMPOSING TO ANY CONCENTRATED RITERIA. THIS tOPERLY ANALYZED BY A T. ONSTRUCTED USING, TYPE YSTYRENE FOAM SHALL IE MANUFACTURED BY 11-0926. 07(OR 1 SHALL BE ADHERED TO DHESIVE(BY ASHLAND 1ANCE WITH APPROVED t ALL PANELS. ULATE OR PROTECT ALL VENT ELECTROLYSIS. TES STRUCTURAL DESIGN BY CONTRACTOR, at. al. ER FOR ALL COST & FEES RESULTING FROM CONSTRUCTION PRACTICES STATE, B FEDERAL CODES NO ADDITIONAL ED. OR OTHER MARKINGS TO 4LIDATE THIS PANEL PROPERTIES: 1. PANEL'STRUCTURAL PROPERTIES DERIVED FROM CERTIFIED TEST REPORTS Nos. HETI-05-1985, -05-1987,-05-1908, -05.1989, 05.1990,-OS-1991,-05-1992,-OS-1993, -05-1994,-05-1995, OS -1996, -OS -1997,-06-2066,-06-2067, -06-2068,-06-2069, 06.2070,-06-2071,-06-2072,-66.2073, 8 -06-2074 BY HURRICANE ENGINEERING & TESTING, Inc. 2. PANEL DEAD LOADS HAVE BEEN FACTORED INTO CALCULATIONS FOR GRAVITY LOADS AS WELL AS CALCULATIONS FOR PANEL PROPERTIES. a yd zzy o 1-1 0 sC m d4 m D z w LL0 inJWz aozw mg° 5O OS 67CLLJZ ov O_o aU u— WL)2 w zy1.. w ! U 3 U1U bpm, oao U poLu 0. 14-1438 1 4 P® E i R oTm PR DUCIT EVALUATION REPORT ENGINEERING EXPRE55R EXPERT PRODUCT EVALUATION REPORT January 30, 2015 Application Number: FL# 5500.1-R4 Project Number: 14-1438 Product Manufacturer: Elite Aluminum Corporation Manufacturer Address: 4650 Lyons Technology Parkway Coconut Creek, FL 33073 Product Name & Description: EPS Foam Core Composite Roof Panels Aluminum / Aluminum Skin Scope of Evaluation: This Product Evaluation Report is being issued in accordance with the requirements of the Florida Department of Business and Professional Regulation (Florida Building Commission) Rule Chapter 61 G20- 3.005, F.A.C., for statewide acceptance per Method 2(b). The product noted above has been tested and/or evaluated as summarized herein to show compliance with the Florida Building Code Fifth Edition 2014) and is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or revisions. Substantiating Data: O PRODUCT EVALUATION DOCUMENTS FLB drawing #14-1438 titled "EPS Foam Core Roof Panels", sheets 1-1, prepared by Frank L. Bennardo, P.E., Inc., signed & sealed by Frank L. Bennardo, P.E. is an integral part of this Evaluation Report. TEST REPORTS Uniform static structural performance has been tested in accordance with Section 1714.3 of the 2004 Florida Building Code per test standard ASTM E72-05 as evidenced in the following test reports by Hurricane Engineering & Testing, Inc. (HETI): 3" Panels with 0.024" Aluminum Facing: HETI -05-1988, HETI -05-1992, HETI -06-2066, HETI -06-2067, HETI -06-2068 3" Panels with 0.032" Aluminum Facing: HETI -05-1993, HETI -05-1989 4" Panels with 0.024" Aluminum Facing: HETI -05-1994, HETI -05-1987, HETI -06-2069, HETI -06-2070, 13 4 Panels with 0.032 Aluminum Facing: Orin HETI -05-1985, HETI -05-1995 P 6' Panels with 0.024 Aluminum Facing: HETI -05-1996, HETI -05-1991, HETI -06-2072, HETI - 06-2073, HETI -06-2074 6" Panels with 0.032" Aluminum Facing: HETI -05-1997, HETI -05-1990 Metal tensile capacity has been determined in accordance with LI ASTM E8-01 test standard per test report(s) #HETI-05-T337 (0.024" alumi 0.032" aluminum facing) by Hurricane Engineering & Testing, Inc. (HETI). 160 SW 12TH AVENUE #106 DEERFIELD BEACH, FL 33442 PHONE: 954-354-0660 FAX: 954-354-0443 WWW.ENGEXP.COM ING Elite aluminum Corp. — EPS Foam Core Composite Roof Panels 2015 STRUCTURAL ENGINEERING CALCULATIONS Structural engineering calculations have been prepared which evaluate the product based on comparative and/or rational analysis to qualify the following design criteria: 1. Maximum Allowable Size/Pressure Combinations No 33% increase in allowable stress has been used in the design of each product. Impact Resistance: Large & Small Missile Impact Resistance has NOT been demonstrated as evidenced in previously listed test reports, and is accounted for in the engineering design of this product. Wind Load Resistance Each product has been designed to resist combinations of wind loads, live loads, and dead loads as indicated in the span schedule(s) on its respective Product Evaluation Document (i.e. engineering drawing). Installation Each product listed above shall be installed in strict compliance with its respective Product Evaluation Document (i.e. engineering drawing), along with all components noted therein. Each product component shall be of the material specked in that product's respective Product Evaluation Document (i.e. engineering drawing). Limitations & Conditions of Use: Use of each product shall be in strict accordance with its respective Product Evaluation Document (i.e. engineering drawing) as noted herein for outdoor patio construction only. All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in each product's respective anchor schedule. Host structure conditions which are not accounted for in each products respective anchor schedule shall be designed for on a site-specific basis by a registered professional engineer. All components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times. Each product has been designed for use outside the High Velocity Hurricane Zone (HVHZ). Product shall be fabricated using expanded polystyrene insulating foam manufactured by Dyplast Products, Inc. as listed in Miami -Dade Notice of Acceptance # 11-0926.07 (or the current version of this NOA). 160 SW 12TH AVENUE #106 DEERFIELD BEACH, FL 33442 PHONE: 954-354-0660 FAX: 954-354-0443 WWW.ENGEXP.COM Land Surveyors 769 Douglas Avenue, Altamonte Springs, Florida. 32794 (407)788"8808 tKernberorrhe F7arlda Srnvaybrg ane McPPlns t3aeleq andAmeriean Congress on SwvaYm9 and Mapp(n9 Map of Survey K URVE TABLE LENG7N RADIUS Oetta THDeltaACa"G1 racre 9 on G 5'1 ab Tract "C' Drainage & Retendon Tract A" a 01-1-111, Mt -m This is Not a Surveyae)orNa a+az iarand rwaraaunn sola Rive -7-Um7 W 49 D r W l- phor n92 L0193 W94Lot95, Ln86 Lot97 Lot98" N as ILOt 91 M a ,5-7 y Y Q A xt! s- Lot99 JUL 48 2015 vapasadsmoe. N547231"W 629.25.'Yi 132 a CIL River Landing Drive wWWas) Tract S"Atxess APPROVED PLANS". LEGAL DESCRIPTION Lots 92,93,94,95,96,97,98, Riverview Toxmhomes Phase Ih a=nsvmLMpW9tereatasm=dedinpblbook atpaga(si - ofdl0 pub60 nxords otSmdno/e Gounty, lima. R.00DM4Z4 LZ4Tit:Thapaleslsherarbemo+&5vXrbtFloodzanex a0mnfrtq&i the Rood truurance Rale Map Pam 12W 4 0060F dakrl Std 12W.. Roodzonedetemrbadanv=pe dbygrdphlcP101tugbomFlood 6su==RataM4psprovided0FEMA.1&&W urvftVWWPe 41 das6rmbdetermza0ritmn2 The eaadmnek+®5oncananybedetamkad tryabdavafarshW. wea=W1?018sPonsNW1 rachraldo0fflW a General Notes: 1. ThB is a etxNJDaRr9rrverPe rarmed In tr,e r rd orL PRaPoSED. 2Noawlal,sudaaorsubsadaceutildYlnslaBaSaras undergmrmdknprovemonfsot wbadocefaerW W aoWhmants Harry, were heated 3.8uBdng ttes shown am ro the estetiorurYnished founda5orr surface ortormtward. , 4. Ekrati0ra5 drawn faerCOr4 Harry; erre a5srrarad erred>.cc aa,(einod riom "pprnwd brasauCJorr phns provfdedby the CaerX caress omanvue noted, arrd areshoam only ro depict thetroposad aractualddlerence to elevation raraima ro the sssumod temporary nenMma rk strewn AW= S The MM hereon )s subject to aff easemants msaiwhons, mshirbans, and fthisd-aWorrecadwhelltetdep' orrotonthisdo awLNosearcho the Pahk Records has been made bythb d5m The kgardesaipt err sAown Hereon is as rumahedby client 7. Potted and measvmd dilances and dbecSorm am tba same unkss dhetwlse rated. a Copies of survoy maybo made forme odgmal transaction any. Denotes )5'kw tad Nod! plasWcap marked L84997, brSFkw rod whh radpbs0c cap madmd'l4rtbuss Comet. unless othenvlu noted O Deno =AcLP. (FermanamcanrmtpobU w Demtes AarmanorrtRe/emncm Mmwnent 2009 Herz E Assodateslne A9 dghts reserved tkra &As,eWras tae. ENG. DEPT. 1 Ok to install screen room with 3" elite panel e F°"`rs Sid, roof on existing slab as shown on plan. The mo screen enclosure shall be constructed with wa,tl daknl same design, material and style as the others in papvedbyEw the nearby and adjacent building. Legend 8 Temp rryacadammk OGRE 05-WRecoad EWk da8a7r)Pa FWBWk BOW a ofrila+vznc FC Pc"rddCaruat" OL cutafae Pea fklnrdtbmp 9.C_ o» A aaammorla.WA1. s tact. Paumumraxrcursaaaer ce catnww P' CWrd eewfiV NcrodArmaaenrRMkvacoLlonamasat C1tMmorled Ppg, ao mtZft EL orELEV SWM5611 0100=4 Par. PMorcM=VMaamv4 RMEL a vaWd fhkw ad) Pl P&IWIbnaes" FD. FwM PRG FOWOFAMersa CWMt FeMS&V FsiBhedFborBarat6n Pr. PamorTargmaaa IP. ftnRpe R Radus LR fta Rod RAD F4KWlkn Le L 8cm&= RES Rstldmaa latY TW. PWWaY rCLStaSTAYsyor Tal! 7emporary&+r+dxnttR AW TVA 7YPW MO(W) nWtWnbN( au to dg) NA ,X -X- FOAM sroa6dpa"Aaainy) inYaaan Sketch of Legal Description Mt -m This is Not a Surveyae)orNa a+az iarand rwaraaunn sola Prepared for.' 701 Hamrs lab SZV"bW. 07.Do501 scow l •-40• plot Pim Ptrtbmud: 05-27.09 Flnarsr"vey- Ravl km' REQUIRED INSPECTION SEQUENCE BP# /S- 2-283 BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'1) Building Ceiling Grid Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Solar Pre -Demo Final Demo Final Single Family Residence Final Commercial —New Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) REVISED: June 2014 Address: ZSQZ IZ lEp- CAt4,t.,•3cs ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final PLUMBING PERMIT Min Max Inspection Description Roof Storm Drain Rough Plumbing Underground Plumbing 2nd Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final