Loading...
HomeMy WebLinkAbout2568 River Landing DrRV l0-tlry o CITY OF SANFORD PERMIT APPLICATION Application # ( v Submittal Date: •/ i RECEIVED Q Job Address: '0"'/1// L 1h,Value of Work: JUL ZOOU Parcel [D:'ffq- . 11 ' I U %Zoning- Historic District: Description of Work: I O Ol l w 1 Square Footage: I Permit Type: Building X Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets 3 Plumbing Repair -Residential Commercial Occupancy Type: Residential 0Commercial Industrial Occupancy Use Group(s): 4/&3 Construction Type: - e # of Stories: # of Dwelling Units: Flood Zone: —tA—/ (FEMA form required Property Owner: ' Contractor: 8 Address: 00 Address: Phone(( l1/ E-mail: Bonding Company: Address Arch Phone: q State License Number: Mortgage Lender: Address: Phone: Address: ,YYIQ/ A5 D11V 1W `) ` A Fax: Plan Review Contact Person: VV . Phone:b%' 'lFax: E-mail: if Mi D s COM Application is hereby made to obtain a permit to do the work and installations as mt cattla 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: l certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. xGg4Q--E: Ina4"on-te the rec}uirements of chis permit there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional pe it required from other governmental entities such as water management distri , state agencies, or federal agencies Ac nc f p rmit erification tha 1 will notify the owner of the pro y of eq e s Q rida Lie Law, FS 713. r d Signature o wner/Agee Date Signature o ontractor/Abent Date WAIN Print Owner/ ent's Name j Print Contract r/Agent's Nam gnature of Notary -State of Florida Date ature of Notary -State of Florida Date y p e Notary Public Sate .:, t , r;n - II PaY P Notary Public State of Florida Jenna Hermans I9, o My Comma , or h4; Owner/Ag Kq i/W a to or TlC1UUl.GLL ti' __- __ APPROVALS: ZONING: RLk UTIL: Special Conditions: Rev 07.07 FD'. 2° t e N ® Jenna Hermans a My Commission DD669642 Expires 05/02/2011 Contractor/.Agent is _ Persona y nown^C 1 Iz ar- ENG: BLDG: LIOZ-00,, D, 9, 5 Y' / I COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 08100003 BUILDING APPLICATION #: 08-10000328 BUILDING PERMIT NUMBER: 08-10000328 UNIT ADDRESS: RIVER LANDING DR. 2568 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: SUBDIVISION: PLAT BOOK: PLAT BOOK PAGE: OWNER NAME: ADDRESS: 3y- d a -M j91,La4L aa,ils ' DATE: August 14, 2008 26-19-30-5SU-0000-1020 PARCEL: TRACT: BLOCK: LOT: APPLICANT NAME: M/I HOMES OF ORLANDO LLC ADDRESS: 300 COLONIAL CENTER PKWY LAKE MARY FL 32746 LAND USE: TOWN HOME UNIT TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 2568 RIVER LANDING DR/TOWN HOME/ RIVERVIEW FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS CO -WIDE ORD Condominium* 379.00 1.000 dwl unit 379.00 ROADS -COLLECTORS N/A Condominium* 00 000 dwl unit FIRE RESCUE N/A 00 00 LIBRARY CO -WIDE ORD Condominium* 54.00 1.000 dwl unit 54.00 SCHOOLS CO -WIDE ORD Multifamily 2,450.00 1.000 dwl unit 2,450.00 PARKS N/A LAW ENFORCE N/A 00 DRAINAGE N/A 00 00 AMOUNT DUE 2,883.00 STATEMENT RECEIVED BY: [ I/(0(, SIGNATURE: PLEASE PRINT NAME) DATE: NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1 -BLDG DEPT 3 -APPLICANT 2 -FINANCE 4 -LAND MANAGEMENT NOTE** PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE, BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 OR CITY OF SANFORD PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. February 18, 2009 Herx & Associates Inc. 769 Douglas Avenue Altamonte Springs, Florida 32714 407.788.8808 - 407.788.8762 (fax) City of Sanford Building Division P.O. Box 1788 Sanford, Florida 32772-1788 RE: Lot 102 Riverview Townhomes, 2568 River Landing Drive To Whom It May Concern, The finished floor elevation of the structure located at: 2568 River Landing Drive, Sanford, Florida Legal Description: Lot 102, "RIVERVIEW TOWNHOMES", according to the Plat thereof, as recorded in Plat Book 74 at pages 46 through 53 Public Records of Seminole County, Florida. Meets or exceeds the requirements set forth in the City of Sanford Code Chapter 18, sections 18-4(a). Sincerely Yours, Herx & Associates In ONN- Darae L. Przemieniecki , P. . Associate Vice President DLP/bb 64W9d0tMffN4r. t Land Surveyors 789 Douglas Avenue, Altamonte Springs, Florida. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and American Congress on Surveying and Mapping 11) Fd LR: a III VIA Tref, Lot 98 PQP e.L.m:.23:1 N se Map of Survey Tract aC° 633.07' CIL River Landing Drive R/W Varies) LEGAL DESCRIPTION Lot 103, RiverviewTownhomes", according tome plat thereofas recorded in plot book 74 at page(s) 46 - 53 or the public records ofSemnmafe County, Florida. FLOOD HAZARD DATA: The parcel shown hereon bas WWWA flood zone W SETBACKS: according to the Flood insurance Rate Map community panel number Front: 21.5' Side : 7.17" Rear: 4,5' 120294.0080E dated 928/2007. BEARING BASE: The bearings shown hereon are based upon the Flood Zane determinaWn was performed by graphic plotting from Flood eastern plat boundary as being N00110100•W. Insurance Rate Maps provided by FEMA. No field surveying. was performed by this firm to determine this zona. The exact zone location can only be determined Vertical datum Is based on enpaxerkrg plans as provided by the orient by en elavatlon shroy. We assume no responsibility for actual flood ng prepared by Evans Engineering, Inc, Job k 12001. conditions_ General Notes: %, 't Legend1. This is a BOUNDARY Survey performed In the meld on 2. No aerial, surface or subsurface utility MsteOadons, underground improvements or e Temporary SendmmaA oR.e. bOftW Records. Book aubsprfacelaadal encroachments, If any, war& located.. ossa od dahun) PB p 3. Building des shown ere to the exterior unilhished foundation surface or b-mboant BOW Beek d aldowalkBo PC RYMcicurvatum 4. Elevations shown homon, If any am assumed and want obtained from approved CanterNM Of to l Angie4CN.0 PCC: POW a Compound Cum&wv Construction plans. provided by the Client unless otherwise noled, and am shown Cwbw P.G.P. Pem—d Control POW only to depict Via proposed or actual difference in elevation relative to the assumedonly Ca. Chord &V P8"RP.R.M. Pwmanant R hrermte sbnumard temporary Benchmark shown hereon. Co Chord PA Pmoat5. The reel shown hereon is subject to all easamenta, reservations, msffiedons, endW C.M. Conerste lfomment P.O.S. of 580e POW ofeepMmrpRights -al -way of record whether depicted or not on His documsn(. No ssarUf of EL or ELEY Elevation(Proposed) FINAL EL Elav ebn (Measwed) P.O.C. Poke of Commenamu+f Public Records has been made by this ofOds. FD. Found P.J. PRG. fix" to/Mlerasdxvt POW of Wvorse Crxvaha. a The kgeldescription shown hereon is Yasfurnishedb dient, Fln.Fl. Eley. PA&hsd loon EW waft" PT. erTan9sncy7. Platted and measured distances and directions Am the some unless otherwise noted. PipeI.P.PIron Pipe RNOtLd4a 8. Copies of this Survey may be made for the original transaction only. I.R. icon Rod RAO Redd Lire e Denotes %' iron. rod with plastic cap marked LB 4937, or W ban rod with L Am Len9M RES. Residence rod plastic cap marked +Nddiess Comer unless otherwise noted. La LboAnd Suermis pity F:pNonwey O Denotes P.C.P.(Permanent contra point) I.S. Land Swwyer Moa Ned wel Tam Tompony eanchmerk s Denotes Permanent Reference Monument WD(Nap) Net and L, Fro drFend symbol ( m Crewing) 04009 bbrx a Associates Inc. Ad fights rosanad N:R Na Radel X. Fence symbol (see draaAnp) Cerlmcauon: Not vow nrhout the tun 4nd the 0090141 felsed sW Drawn by CM of a Pterfde fieenaed 9umeyeresd - F Mlnlmu Tseh Chocksd by: DP ThfLaurvey meats Me a n Sten as contalrod in Cho err 1 Adnrdstraave Prepared for.M/1 Homes Job Number: 07-005-0f V41 Scale: 1"- 40' Plot Plan Performed: 05-1948 VANiam A Nor., P LS. da pegletend Lan urveyo,lia 3082 Foundation Survey: 09-03.08 Darae L Pnembnaekt, P.S. M. Ra9Mersp 3 and Mapper No. 6030 Final Survey: 02.16-09 Nem+ A Associates Inc., state efFbdds LS 1 7 I y " r%9: Revisions: Building Photographs Continuation Paqe For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 2568 River Landing Drive City State ZIP Code Company NAIC Number Sanford Florida 32772 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." Rear View Building Photographs See Instructions for Item A6. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 2568 River Landing Drive City State ZIP Code Company NAIC Number Sanford Florida 32772 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. Front View IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use:,-,-,- „ " Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 2568 River Landing Drive City State ZIP Code Company NAIC Number, Sanford Florida 32772 SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Item C2.e represents the elevation of the AC machinery pad Flood Zone was determined only by graphic plotting on FEMA Firm maps H ssociates, Inc. as no res onsibilit forc al flooding conditions. ignature Date 2-18-09 n Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is feet meters above or below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is feet meters above or below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (seea e 8 of Instructions), the next higher floor elevation C2.b in the diagrams) of the building is Elfeet Elmeters above or below the,HAG. E3. Attached garage (top of slab) is feet meters above or below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is feet [:]meters above or F-] below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? Yes No Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3. The following information (Items G4. -G9.) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: New Construction Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: El feet El meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: feet meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments Check here, if attachments FEMA Form 81-31, February 2006 Replaces all previous editions U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency Management Agency Exoires February 28, 2009 National Flood Insurance Program Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION For Insurance Company Use: Al. Building Owner's Name Policy Number M/1 Homes A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number 2568 River Landing Drive City State ZIP Code Sanford Florida 32772 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 102, Riverview Townhomes, Plat Book 74 Pages 46-53 Seminole County, Florida A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 28°48'48.1" Long. -81°17'48.7" Horizontal Datum: NAD 1927 ®NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 1 A8. For a building with a crawl space or enclosure(s), provide: A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) 0 sq ft a) Square footage of attached garage 254 sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade 0 walls within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State City of Sanford & 120294 Seminole County FI B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone feet meters (Puerto Rico only) Date Effective/Revised Date Zone(s) AO, use base flood depth) 120294 0060 F 9/28/2007 9/28/2007 X N/A B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. FIS Profile FIRM Community Determined Other (Describe) N/A B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 ®NAVD 1988 Other (Describe) N/A B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes ®No Designation Date CBRS OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: Construction Drawings" Building Under Construction" ® Finished Construction A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item AT Benchmark Utilized Seminole County BM 8095501 Vertical Datum NAVD 88 C1%1 Conversion/Comments N/A NZ a) Top of bottom floor (including basement, crawl space, or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. t certify that the information on this Certificate represents my best efforts to interpret the data available. 1 understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Check here if comments are provided on back of forms" Certifier's Name License Number Darae L. Przemieniecki PSM 6030 Title Company Name PrnfascinnA SI1ryPyor and Manner tf-ierx & Associates. Inc. Address ity State ZIP Code ou las Avepue e ,tamonte Springs Florida 32714 Signat a _ _ • Date Telephone FEMA Form 81-31, February 2006 See reverse side for continuation. Check the measurement used. 24.7 feet meters (Puerto Rico only) N/A feet meters (Puerto Rico only) N/A feet meters (Puerto Rico only) 24.4 feet meters (Puerto Rico only) 24.0 feet meters (Puerto Rico only) 23.9 feet meters (Puerto Rico only) 24.1 feet meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. t certify that the information on this Certificate represents my best efforts to interpret the data available. 1 understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Check here if comments are provided on back of forms" Certifier's Name License Number Darae L. Przemieniecki PSM 6030 Title Company Name PrnfascinnA SI1ryPyor and Manner tf-ierx & Associates. Inc. Address ity State ZIP Code ou las Avepue e ,tamonte Springs Florida 32714 Signat a _ _ • Date Telephone FEMA Form 81-31, February 2006 See reverse side for continuation. evWx * ®tea ffnes Land Su..r,veyors 789 Douglas Avenue, Altamonte Sprltigs, Florlda. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and Amerirnn Congress on Surveying and Mapping Lot 98 7.2 a 19.2' 78' Brantford Map of Survey Tract "C" Drainage & Retention 2.r LU y Lot 99 of 100 Lot 101 2.r 8.3' ar N N ° w Mc 18.01 1 f.3' j 20.0' F I2TJ - if 5r 9.: i Dryford' case 7-0nit Tc wnhome 0'D x 1757vi iished Floor Ell .: 25.3 Lot 102 Lot 103 N 7.B' Brantford As cm . 2.r Tract "F" Lot Lot 105 y w parking B. 2.7 w ar ° o iB.O' 7.2 36.20 j 21.E j j x.00 j j KRt30 i S 54 °22'31 " E 190.01 cn EL: 23.0 CA. EL: 24.3 A 428.93 PCP Inlet N 54 22 31 " W633.07(Plat) Inlet N 54 2231 " W 629.26(Calc) CIL Tract "B"Access R/W varies) PERMIT # t DATE: LEGAL DESCRIPTION Lots 99,100,101,102,103,104,105, "Riverview Townhomes", according to the plat thereof as recorded in plat book at page(s) of the public records of Seminole County, Florida. FLOOD HAZARD DATA: The parcel shown hereon lies within flood zone X" according to the Flood Insurance Rate Map community panel number 120294-0045E dated 4/17/1995, Map Number 12117CO045E. Flood Zone determination was performed by gpahic plotting from Flood insurance Rate Maps provided by FEMA. No field surveying was performed by this firm to determine this zone. The exact zone location can only be determined by an elevation study. We assume no responsibility for actual flooding conditions. General Notes: PROP05 ED1. This is a BOUNDARY Survey performed in the field on _ 2. No aerial, surface or subsurface utility installations, underground improvements or subsurface/aerial encroachments, if any, were located. 3. Building ties shown are to the exterior unfinished foundation surface or formboard. 4. Elevations shown hereon, if any, are assumed and were obtained from approved Construction plans provided by the Client unless otherwise noted, and are shown only to depict the proposed or actual difference in elevation relative to the assumed temporary Benchmark shown hereon. 5. The parcel shown hereon is sublett to all easements, reservations. restrictions, and Rights-of-way of record whether depicted or not on this document. No search of the Public Records has been made by this office. 6. The legal description shown hereon is as furnished by client. 7. Platted and measured distances and directions are the same unless otherwise noted. 8: Copies of this Survey may be made for the original transaction only. 0 Denotes W iron rod with plastic cap marked LB4937, or W iron rod with read plastic cap marked "Witness Corner", unless otherwise noted. O Denotes P.C.P. (Permanent control point) Denotes Permanent Reference Monument 2008 Herx & Associates Inc. All rights reserved Certification: Not valid without the signature and the original raised seal torlda licensed Surveyor and Me per This s ey meats the requirement of the orida Minimum lrnical SETBACKS: Front: 21.5' Side : 7.17' Rear: 4.5' Comer. BEARING BASE: The eastern plat boundary as being N00°10100"W. Vertical datum is based on engineering plans prepared by Evans Enginerring Inc. Job Number 12001. Legend Temporary Benchmark O.R.B. assumed datum) BOW Back of sidewalk C/L Centerline Id Central or (Delta) Angle CALC Calculated CB Chord Bearing CD Chord C. M. Concrete Monument. EL. or ELEV Elevation (Proposed) FINAL EL. Elevation (Measured) FD. Found Fin.Fl. Elev. Finished Floor Elevation LP. Iron Pipe I.R. Iron Rod L Arc Length LB Licensed Business LS. Land Surveyor Mea Measured N/D(N&D) Nail and Disk N.R. Not Radial Standar ascontainedinCh ter iG17- FloridaAdministr ti Code. Sketch of Legal Description M This is Not a Survey William A. Herx, P.L.S. Florida Registered d Surveyor No. 3182 Darae L. Przemieniecki, P.S.M. Registerej Surveyor and Mapper No. 6030 William R. Herx, P.S.M. Registered Survey rend Mapper No. 6092 Herx & Associates Inc., State of Florida LB 4937 0/S Offset O.R.B. Official Records Book PB Plat Book PC Point of Curvature PCC. Point of Compound Curvature P.C.P. Permanent Control Point PG. Page P.R.M. Permanent Reference Monument P2 Property Line P.O.B. Point of Beginning P.O.C. Point of Commencement P.1. Point of Intersection PRC. Pointof Reverse Curvature PT. Point of Tangency R Radius RAD Radial Line RES. Residence RAN Right -of --Way TBM Temporary Benchmark TYP. Typical Fence symbol (see drawing) X-X- Fence symbol (see drawing) Checked by: DP Prepared forMfl Homes Job Number: 07-005-01 Scale: 1"=40' Plot Plan Performed: 05-19-08 Foundation Survey., Final Survey. Revisions: FORM 60OA-2004RICE EnergyGaugeO 4.5.2 L Iq Er A ICI Y CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: RV 102, Unit D 1830 GL SW Builder: MI Homes Address: G6 elva a 1 llYA PrLy, Permitting Office: Sanford City, State: Permit Number: Owner: MI Homes Jurisdiction Number: 691500ClimateZone: Central NIA5. 1. New construction or existing New _[ 13. Cooling systems 2. Single fatnityornudti-family Multi-ramilY Cap: 27.9k13tu/hr3. NumheroY'units,ifnnulti-feunil Number of I4 dro°ms CentralUnit/Split 3 NIA5. SEER: 14.0(14. Is this a wors;l case'? No6. Conditioned Moor area (ti=) 1830 fl' N/A 7. Glass typel and area: (1_,abcl rcxld. by 13-104.4.5 ifnot deflulf) a. U -factor: Description Arca I-Iealing sys ns or Single or Double DF_F'AULT) 7a. (Dble, U=0.7) 147.0 I1' Y lectric 1leaYtmp/Split Cap: 29.1 kl3hu/hrb. SHGC: or Clear or Tint DEFAULT) 7b. (SI-IGC=0.67) 147.0 IF b. N/A HSPF: 8.50 - 8. Floor types a. Raised Wood R=19.0, 206.0 112 a N/A b. Slab -On -Grade Edge Insulation, 0 R-0.0, 76.0 11' c. 1 Others 24.011- _ 14. Hot water systems 9. Wall types a. Concrete, Int hisul, l xterior R=9.1, 244.0 fl' a. Electric Resistance Cap: 50.0 gallons - b. Frame, Wood, Adjacent R=13.0, 237.0 112 j} pb. N/A PERMIT EF: 0.95 - c. Frame, Wood, Exterior R=13.0, 352.0 112 d. Concrete, Int Insul, AdjacentJ cR=9.1, 73.0 f1= c. Coil serval i(its c. N/A HIL -Heat recovery, Solar10. CeiIingtypes DHP-Declicatedheat pump) a. Under Attic R=30.0, 1018-011- 15. HVAC crxiiIs b. N/A CF -Ceiling fan, CV -Cross ventilation, c. N/A HF -Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AI-I(Scaled):Interior Sup. R=GO, 200.011 MZ -C -Multizone cooling, b. N/A MZ -H -Multizone heating) Glass/Floor Area: 0.08 Total as -built points: 17157 PASSTotalbasepoints: 21364 A I hereby certify that the plans and specifications covered by this calculation are in compliance with the orida Energy Code. PREPARED BY DATE: - I hereby certify that this building, as with the Florida Energy Co OWNER/AGENT: DATE: 1 Predominant glass type. For actual gla Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCPB v4.5.2) y p4 THE STgT O