Loading...
HomeMy WebLinkAbout2567 River Landing DrCYTY OF SANFORD PERMIT APPLICATION Application #: 0 4 1 Q% Submittal Date: Job Address: Value of Work: $ ® I % Zoning: Historic District. o Parcel [D' _" g Description of Work: o oa i V"t Square Footage: Iun/ Permit Type: Building Electrical Mechanical F1 Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non-Reside6tial Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets 3— Plumbing Repair -Residential Commercial Occupancy Type: Residential Eilll Commercial Industrial Occupancy Use Group(s): o2 3 Construction Type: _ y # of Stories: 91 # of Dwelling Units: Flood Zone: —C, (FEMA form required ) I.................................................................. .... ................. Property Owner: t Contractor: Address: no 0fnI M Address: Phone ( Vll E-mail: , Bonding Company: Address: Architect/Engineer: Phone:9 1 State License Number: Ci Mortgage Lender: Address: Phone: Address: to Y OINr 'J^' v Fax: Plan Review Contact Person: N. Phone:gb71 'JFax: E-mail: V?) ail: AD WS, GoM Application is hereby made to obtain a permit to do the work and installations as inil'icated- l certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies- Accepta of ermit ver ation that I willn tify the owner of the property of th quirements of ida Lien Law FS 7 3. Signature of er/Agent date Signature of ontractor/ ent Date/ I Print owner/p 's Name J int Contract gent's Nam Sig azure of Notary -State of Florida Dae Si azure of otary- tate of Florida Date P"Y °ve Notary Public State of Florida o Par PVB' Notary Public Slate of Florida r° Jenna Hermans Jenna Hermans o My Commission DD669642 My Commission DD669642 9lEl.' 9rfOF Expires ®5 2011rs —"mak' 05/02/2011 Owner/Agent is, Personally Known to Me or Contractor/Agent is 1.9eesonally Knownto Me or APPROV, ALSi. ZONING: UTIL: FD: /BLDG: Special Condit -ions: Rev 07.07 COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 09100001 DATE: March 16, 2009 BUILDING APPLICATION #: 09-10000101 BUILDING PERMIT NUMBER: 09-10000101 UNIT ADDRESS: RIVER LANDING DRIVE 2567 26-19-30-5SU-0000-0180 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: M/I HOMES OF ORLANDO LLC ADDRESS: 300 COLONIAL CENTER PKWY LAKE MARY FL 32746 LAND USE: TOWN HOME TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 2567 RIVER LANDING DR. / TOWNHOME FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS CO -WIDE ORD Condominium* 379.00 1.000 dwl unit 379.00 ROADS -COLLECTORS N/A Condominium* .00 1.000 dwl unit 00 FIRE RESCUE N/A 00 LIBRARY CO -WIDE ORD Condominium* 54.00 1.000 dwl unit 54.00 SCHOOLS CO -WIDE ORD Multifamily 2,450.00 1.000 dwl unit 2,450.00 PARKS N/A 00 LAW ENFORCE N/A 00 DRAINAGE N/A 00 AMOUNT DUE 2,883.00 j STATEMENT RECEIVED BY: Odrr SIGNATURE: PLEASE PRINT NAME) DATE: NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1 -BLDG DEPT 3 -APPLICANT 2 -FINANCE 4 -LAND MANAGEMENT NOTE** PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT, PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE, BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. 0q,_ 4III Permit Number M/I Homes Folio/Parcel ID Number 26-19-30-5SU-0000-0180 Prepared By Jenna Hermans Interest in Property Fee Simple Interest Return To 300 Colonial Center Parkway, Ste. 200 1 IHI 111111111101111111111 It III 111111111111 It 11111 11 III I illi MARYANNE MORSE, CLERK WCIRCUIT COURT SEMINOLE CIMTY BK 0-/171 Pq Qpq) CLERK' S # ;P+:);_`_i00&875 REWkbfl) t111 `117titt f7:a: ;3:U3 PH RECUROIN6 FEES 10.0* RECORDED BY L McKinley CERTIFIED COPY Lake Mary, FL 32746 MARYANNE MORSE; CLERK OF CIRCUIT WIRT NOTICE OF COMMENCEMENT ISEMINOLE C UNC FLORIDA State of Florida, County of Seminole The undersigned hereby gives notice that improvement(s) will be made to certain real property, and EPUTvCLERK accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of nCommencement. JAN ' 2091. Description of property (legal description of theproperty, and street address if available Riverview, Lot 18: 2567 River Landing Drive 2. General description of improvement(s) Townhomes 3. Owner information Name M/I Homes Telephone Number 407 531-5100 Address 300 Colonial Center Parkway, Suite 200 Lake Mary, FL 32746 Interest in Property Fee Simple Interest 4. Fee Sim Ie Title Holder if other than owner shown above Name N/A Telephone Number I N/A Address N/A 5. Contractor Name M/I Homes Telephone Number 407 531-5100 Address 1 300 Colonial Center Parkway, S.uite 200 Lake Mary, FI 32746 6. Suretv (if anv) Name N/A Telephone Number N/A Address I N/A Amount of Bond $ N/A f. Lender It an Name N/A Telephone Number I N/A Address N/A 8. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by §713.13(1)(a)7, Florida Statutes. Name Larry Sekely I Telephone Number 407 531-5168 Address 300 Colonial Center Parkway, Suite 200 Lake Mary, FI 32746 9. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in §713.13 1 b , Florida Statutes. Name VA I Telephone Number 407 531-5100 Address 1 300 Colonial Center Parkway, Suite 200 Lake Mary, FI 32746 10. Expiration date of notice of commencement (the expiration date is one year torm the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY.THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE.OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Fred Sikorski Signature 6fOwner Signatory's Printed Name/Title/Office or Owner's Authorized Officer/Director/Partner/Manager §713.13[1][d]) The foregoing instrument was acknowledged before me this r Uday of `1 1 '' by Fred Sikorski year) (name of person) as Regional President for M/I Homes Type of authority, eg., officer, trustee, attorney in fact) (Name of party on behalf of whom instrument was executed) 21- Signature of Notary Public- State of Florida Personally Known, OR Produced ID Type of ID Produce Print, type, or stamp commissioned name of Notary Public) Verification pursuant to Section 92.525, Florida Statutes: Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. t2'1: Signature of Natural Person Signing on Line 11 -Above Form Revised: 11/19/07 tX otal PL)bli St i y ale t "lorida 2 fi1a15 wr 06s3642 OF {% xpii s,05/02/201 1._... M_. Verification pursuant to Section 92.525, Florida Statutes: Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. t2'1: Signature of Natural Person Signing on Line 11 -Above Form Revised: 11/19/07 tX Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Date: Project Name: Project Address: j1o1 V 1 l Building Permit #: (A-" (M ?i Electrical Permit #. In consideration for authorizing the appropriate utility company to energize the facility, we agree with and understand the following: . 1. The facility will not be occupied until a certificate of occupancy has been issued. 2. If the jurisdiction hereafter finds that the facility has been occupied before a certificate of occupancy has been issued, the jurisdiction will have the unilateral right to direct the utility to terminate electrical service without notice. Furthermore, we understand and agree that -should the jurisdiction exercise such right, the jurisdiction will not be responsible for any damages or costs which may result from the exercise of such right. Also, in the event any third party claims damages from the exercise of such right, we agree to jointly and individually indemnify and hold harmless the jurisdiction from all such damages and costs, including attorney's fees. 3. The building or structure shall be weather tight and secure. The electrical wiring in the area designated for pre -power shall be complete and in safe order. All electrical services associated with the area will be 100% complete unless specifically approved by the electrical inspector. 4. Interior electrical rooms shall be lockable, if electrical panels are in an area that cannot be locked by doors, the panels shall be equipped with a locking mechanism (approved by the AHJ). The licensed electrical contractor or his licensed representative shall hold the keys(s) for such access to electrical panels to prevent energizing circuits other than those that are safe. 5. If provided, the fire sprinkler system must be operational, per the local AHJ requirements, with water on the system prior to pre -power. 6. This pre -power approval is valid for a maximum of 180 days from date of approval. 7. Check with the local jurisdiction for fees associated with pre -power. N Print Nam VO /T nt Print am on ctor ignature of Ownetftenant Signature of Gen. tractor JURISDICTION EMPLOYEE N JURISDICTION: CALLED INTO: Rev. 3/27/07) L`4yZ1?r,1dM Gen. Contractor License ky i S t Print Name of El. Contractor Signature of El. Contractor yy/(a El. Contractor License # Progress Energy Florida Power and Light on _/_/ CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: () _ vl 2( Documented Construction Value: $. 500 - 00 Job Address: R VF;i LG, (O" n G or-- Historic District: Yes No Parcel ID: 7 - 3G - 5 U`Uy - UIS Zoning: Description of Work: Plan Review Contact Person: Phone: Fax: E-mail: Title: Pro/pely Owner Information Name N I U U T" 1. Phone: Street: J F,t LcJ Resident of property?: City, State Zip: Gc I/ 3 Z7 ( P Contr ctor Information , ` f Name : n Ks -U Vt r Phone: /='Qy - Street: [ ( Lj • P ii ( r)ov- U d Fax: L{'C) City, State Zip: ,) In J .i L 73 State License No.: Name: Street: City, St, Zip:, Bonding Company: Address: Building Permit Square Footage: No. of Dwellin Units: Electrical New Service - No. of AMPS: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: Mechanical 0 (Duct layout required for new systems) No. of Stories: Plumbing New Construction - No. of Fixtures: Fire Sprinkler Alar Q -`No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charge exceed the documented construction value when the executed contract is submitted, credit will be applied your permit fees when the permit is released. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID' Type of ID APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 04 Signature C/Cont w(tor/Agent Print ContraVor/Agent's Name gnature of Notary -Stat F onda Date 40 SAMANTHA L FURBOTER MYCOMMISSION # DD865138EXPIRESMarch01, 2013 FloridallotaryS ice.com 8 4153 ractor/Agent is Personally Known to Me or Produced ID Type of ID UTILITIES: FIRE: WASTE WATER: BUILDING: POWER OF ATTORNEY Date: 7i L I hereby name and appoint K Z/r Vl "C U of BRINKS HOME SECURITY to drop off and pick up permits at the el-M Cj AcynoTyrrj Building Department on my behalf for a LOWIO_L AGE SECURITY Permit for work to be performedata location described as: 7 Parcel ( ` [ ( '30 6S d l/ n 1 13-0 Subdivision R ( u&ryi t(/w 'Tbcy nbr, )n S Address of Job Owner Or. Type of Print Name of/C/rtified Contractor Signature of flertified Contractor The foregoing instrument was acknowledged before me this day of 20 by Douglas Bassett who is personally known to me/who produced as identification and who did not take oath. State of Florida County of Notary Pubic, Seminole County, F orida q, cEl I A ETki A KING F'S ` a My CC1tiUNlw aON # pD722.C4g F-XPIRE« Oct ober C16. 2011 koslG r1404 rl r Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 http://www. scpafl.org/web/re_web. seminole_county_title?parcel=26193 05 SU00000180&c... 6/24/2009 DAVID JoHNSom GFA, ASA r PROPERTY Vµ , APPRAISER///TRACT F SEMINOLE QOUNTY FL. 1101 E.FIRSTs7 32771.1468 QSANFO'RD, FL 403 - 555 -7508 y VALUE SUMMARY 2009 2008 GENERAL VALUES Working Certified Parcel Id: 26-19-30-5SU-0000-0180 Value Method Cost/Market Cost/Market Owner: M/I HOMES OF ORLANDO LLC Number of Buildings 0 0 Own/Addr: SUITE 200 Depreciated Bldg Value $0 $0 Mailing Address: 300 COLONIAL CENTER PKWY Depreciated EXFT Value $0 $0 City,State,ZipCode: LAKE MARY FL 32746 Land Value (Market) $11,000 $22,880 Property Address: 2567 RIVER LANDING DR SANFORD 32771 Land Value Ag $0 $0 Subdivision Name: RIVERVIEW TOWN HOMES Just/Market Value $11,000 $22,880 Tax District: S1-SANFORD Portablity Adj $0 $0 Exemptions: Save Our Homes Adj $0 $0 Dor: 0003 -VACANT TOWN HOME Assessed Value (SOH) $11,000 $22,880 Tax Estimator 2009 TAXABLE VALUE WORKING ESTIMATE Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund $11,000 $0 $11,000 Schools $11,000 $0 $11,000 City Sanford $11,000 $0 $11,000 SJWM(Saint Johns Water Management) $11,000 $0 $11,000 County Bonds 1$11,000 $0 $11,000 The taxable values and taxes are calculated using the current years working values and the prior years approved millage rates. 2008 VALUE SUMMARY SALES 2008 Tax Bill Amount: $433 Deed Date Book Page Amount Vac/Imp Qualified 2008 Certified Taxable Value and Taxes DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS Find Comparable Sales within this Subdivision LAND LEGAL DESCRIPTION Land Assess Method Frontage Depth Land Units Unit Price Land Value PLATS: Pick.. LOT 0 0 1.000 11,000.00 $11,000 LOT 18 RIVERVIEW TOWNHOMES PB 74 PGS 46 - 53 Permit I NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. Ifyou recently purchased a homesteaded property your next ear's property tax will be based on JustlMarket value. http://www. scpafl.org/web/re_web. seminole_county_title?parcel=26193 05 SU00000180&c... 6/24/2009 nn. I HOMES mlhomes.com Sales Summary Sheet Purchaser : 0f" mP_q Community ILoi- 1 l dt) Una+ Completion of this form will finalize the requirements necessary to proceed with the start of your new home. Your signature on this form acknowledges the inclusion of option selections of the following nature: Structural changes including moving or adding windows, doors, walls, etc.), the addition or relocating of any plumbing, electrical, mechanical devices or concrete. If a change of this nature i*sjL2W&ted after the submission of this form, you will be charged a non-negotiable redraw and processing fee of $ddition to the cost of the change itself. Model l Elevation: &5-o j 4 Address: -7 Garage size: 2 Car 2 Car 3 Car Garage Handing: Right Left X Predetermined) by Roaster plan Driveway Style: Pool: Other Instructions Front Load Yes Side Load Carriage Entranca No Initials Permitting of your home will proceed upon completion of this form. House plan, elevation or structural changes will not be allowed after completion of this form. Initials Construction of your home will not start until the color selection sheet has been completed, 2nd deposit monies have been submitted, financing has been applied for, loan pre -approval has been obtained, and a building permit from the local municipality has been obtained. Initials Change Order Policy: Changes after the completion of your selection sheets will be j d on an individual request and will require an additional processing fee of er change to be paid upon change order submittal. This fee is in addition to the of the change being requested. (A check in the amount of the change order fees must be attached to the change order. The cost of the options added can be included in your mortgage or paid in cash.) No changes will be considered after insulation. Initials Your Construction Supervisor will schedule a Builder/Purchaser Conference at the start of construction. You will meet at the home -site to review the building process. No changes can be made at this conference. Initials PURCHASERS): The electrical layout is attached showing the placements of fan prewires, cable T.V. prewires, phone prewires, security system key pads and any other electrical options that you have included with your sales contract. Date Date Home Phone Work Phone Co -Purchaser's Work Phone SELLER: M/l HOMES F ORLANDO, LLC, a Florida I li it company Sales Consultant Dare; BY: 49 Area Oresident, Division Presid nt or Date VP - Sales and Marketing NOT BINDING UPON SELLER UNTIL SIGNED BY AREA PRESIDENT, DIVISION PRESIDENT OR VP - SALES AND MARKETING CF T -Orlando 9/05 Page I of 2 2/17/2009 M HOME ADDENDUM A mihomes.com COMMUNITY LOT # HOUSETYPE - ELEVATION Riverview Townhomes 0018 Castine - A HOME CONSULTANT GARAGE LOC. STREET FACING 2567 River Landing Dr— FIRSTFIRST M.I. LAST FIRST M.I. LAST BUYER E-MAIL ADDRESS CO -BUYER E-MAIL ADDRESS BASE PRICE LOT PREMIUM L.- z'' n, s6,t"`,ySrP cN:• ^c mss' Ah,y u,w.•" 4; ^fie''-'+ i`2 '`*. •`4[ 4r ,,J,^*.. ¢, i .""„` R lR ronf t eLl^., o...i.FK7',Sa. W. .2r.. _;nr,.r '..,arri* kr.?.. Ku+._.. s..e k yy- i.,.3.,i i k iv 4.•.v 17 February 1198 Lighting and Fans Included Coach Light Fixture HOR i 2009 7 17 February 1211 Lighting and Fans Included Light Fixture Bath #3 HOR 1 2009 0 17 February 1253 Door Styles and Included Interior Door Knobs 1 2009 1 Hardware 17 February 1253 Door Styles and Included Front Door Handleset 1 2009 2 Hardware 17 February 1282 Cabinets Included Level 1 Cabinets I 2009 9 17 February 1283 Countertops Included Laminate Countertop in Kitchen 1 2009 0 17 February 1283 Countertops Included Laminate Countertop - Master Bath Vanities 1 2009 1 17 February 1283 Countertops Included Laminate Countertop Bath 2 1 2009 2 17 February 1283 Flooring Included Carpet Level 1 1 2009 6 17 February 1283 Flooring. Included Level I Floor Tile Foyer 1 2009 7 17 February 1283 Flooring Included Level i Floor Tile in Kitchen/Nook 1 2009 8 17 February 1283 Flooring Included Level I Floor Tile in Master Bath 1 2009 9 17 February 1284 Flooring Included Level 1 Floor Tile In Bath 2 1 2009 0 117February1284FlooringIncludedLevelIFloorTileinUtilityRoom 2009 2 17 February 1317 Appliances Included Dishwasher 1 2009 9 117February1318AppliancesIncludedMicrowave 2009 0 17 February 1318 Appliances Included Range 1 2009 1 117February1321LightingandFansIncludedDiningLightFixtureHOR 2009 6 17 February 1321 Lighting and Fans Included Master Bath Light Fixture HOR 1 2009 8 17 February 1321 Lighting and Fans Included Bath 2 Light Fixture HOR i 2009 9 17 February 1323 Kitchen Included Kitchen Faucet HOR/TOW I 2009 7 Selections 17 February 1326 Exterior Finish Included Satin Exterior Paint 1 2009 8 17 February 1519 Decorative 2" Faux Wood Blinds I 2009 I Interior Finishes 17 February 1328 Bath Selections Included Master Bath Faucet Suite 1 2009 3 17 February 1328 Bath Selections Included Secondary Baths Faucet Suite 1 2009 4 Orlando: 1/6/20091 h M/1 HOMES" ADDENDUM A Page 2 of 2 211712009 TOTAL OPTIONS AT CONTRACT TOTAL CONTRACT PRICE (including premiums, if any) I Date Date Orlando: 1/6/2009) M/1 HOMES OF ORLANDO, LLC a Florid7ied liability company By: ZA.11 JA Sales Consultant D By: /I ?J " fsx, Authorize a Agent Y - Date N-W-ONON" R-, 17 February 1329 Bath Selections Included Acrylic Shower Floor Pan 2009 4 17 February 1329 Bath Selections Included Commodes and Sink Color 2009 6 17 February 1329 Bath Selections Included Level I Shower Floor Tile Master Bath 2009 7 17 February 1330 Flooring Included 6Lbs. Carpet Pad 2009 5 17 February 1330 Bath Selections Included Level I Wall the Master Bath 2009 6 17 February 1330 Bath Selections Included Level I Wall tile Bath 2 2009 7 17 February 1331 Door Styles and Included Front Door Paint Color 2009 0 Hardware TOTAL OPTIONS AT CONTRACT TOTAL CONTRACT PRICE (including premiums, if any) I Date Date Orlando: 1/6/2009) M/1 HOMES OF ORLANDO, LLC a Florid7ied liability company By: ZA.11 JA Sales Consultant D By: /I ?J " fsx, Authorize a Agent Y - Date arzoraoos TON _ .HOMES WITH SUNRISE SERIES SPECIFICATIONS CUSTOMER NAME JOB R U I FOUNDATION AND SLAB I. COMPACTED FILL 2. MONOLITHIC SLAB AND FOOTING 3. CONCRETE SLAB, MINIMUM 316' THICK, 2500PSI CONCRETE 4. RECESSED EXTERIOR SLIDING GLASS DOORS 5. BRICK PAVERS UNDER GARAGE DOOR RECESSED 3114' 6_ VMQUEEN VAPOR BARRIER UNDER ALL CONCRETE FLOORS 7. SLAB CONTROL JOINTS ON GARAGE FLOORS MASONRY WALL 1. EXTERIOR MASONRY CONSTRUCTION WITH STANDARD 8"X 8" X 16- TWO -CELL CONCRETE BLOCK 2. STEEL REINFORCED MASONRY LINTEL ENGINEERED TO MEET WIND LOAD REQUIREMENTS 3. TRUSS STRAPS SET IN CONCRETE PER TRUSS PLAN 4_ ANCHOR BOLTS SET FOR GARAGE DOOR 5. VERTICAL REINFORCEMENT FILLED CONCRETE CELL WITH (1) 96 REBAR IN MASONRY WALLS 6. FLUSH PRECAST WINDOW SILLS FRAMMG 1. TRUSSES ENGINEERED FOR 37 LB. LOAD AT 24 ON CENTER 2. BORACARE (TERMITE TREATMENT) 2 FEET UP ON FIRST FLOOR WALLS 3.2 X 4 WOOD STUDS 16' ON CENTER WITH DOUBLE 2 X 4 TOP PLATE ON LOAD BEARING WALLS 4.1X2 PRESSURE -TREATED FURRING STRIPS ON MASONRY WALLS, 24' ON CENTER (16' O.C. IN TUB AND SHOWER AREAS) S. BLOCKING FOR DRAPERY RODS 6.7116' ORIENTED STRAND BOARD ROOF SHEATHING 7. WHITE ALUMINUM FASCIA AND DRIP EDGE WITH 2 X 4 SUB -FASCIA 8. VENTED ALUMINUM SOFFIT PER PLAN PLUMBING ELECTRICAL I-'FLOWGUARD GOLD' CPVC PIPING UNDER SLAB. 2 MAIN WATER SERVICE SHU r -OFF, AT METER WITH SECONDARY SHUT-OFF AT HOUSE 3. PROFLO BY BRIGGS ELONGATED 1 S GALLON 'WATER SAVER- WATER CLOSETS IN ALL BATHS (UNEN) 4. PROFLO BY BRIGGS CHINA LAVATORIES (LINEN) . 5. MIEN CHATEAU #4920 DUAL HANDLE LAVATORY FAUCETS CHROME 6. QUICK RECOVERY 40 GALLON ELECTRIC WATER HEATER 7. STAINLESS STEEL 6' DEEP DOUBLE BOWL KITCHEN SN( 33X22 S. MOEN SINGLE LEVER CHATEAU KITCHEN FAUCET#7430 CHROME 9.. STERLING 4 PIECE ACRYLIC TUB IN SECONDARY BATHS (PER PLAN) BISCUIT 10. MASTER BATH TUB-JACU2ZI NOVA ACRYLIC (OYSTER) 11. DECK MOUNT FAUCET AT MASTER BATH TUB CHATEAU CHROME TWO HANDLE #4962 12 WASHER AND DRYER HOOK-UPS 13. ONE (1) HOSE BIBS CONVENIENTLY LOCATED 1. ALL INTERIOR COPPER WIRING PER CODE 2 R6 QUADSHIS-0 CABLE T.V. OUTLETS: ONE (1) IN MASTER BEDROOM AND ONE (1) IN GREAT ROOM 3. CARBON MONOXIDE / SMOKE DETECTORS- ONE AT EACH FLOOR AND HALL NEAR BEDROOMS 4. CHUNG FAN PREWIRES: ONE (1) IN MASTER BEDROOM AND ONE (1) IN GREAT ROOM 5. 150 AMP ELECTRICAL SERVICE S. TWO (2) OUTDOOR RECEPTACLES 7. CAT 5 TELEPHONE OUTLETS: ONE (1) IN KITCHEN AND ONE (1) IN MASTER BEDROOM 8, RECESSED LIGHT AT FRONT ENTRY s_ COACH LIGHT PRE -WIRE INCLUDING FIXTURE (SL944") 10. GARAGE DOOR OPENER WITH KEYLESS ENTRY 11. PREWIRE FOR BRINKS SECURITY SYSTEM WITH ONE KEYPAD 12. SUNRISE LIGHTING PACKAGE 13. ELECTRICAL ARC FAULT BREAKERS FOR BEDROOM CiRCUn 14. SURGE PROTECTOR LOCATED ON MAIN PANEL 15. TOGGLE SWITCHES WHITE 16. ON Q BOX -LOCATION PER PLAN 1. 14 SEER ENERGY STAR RATED AIR HANDLER AND HEAT PUMP COMBINATION 2. PROGRAMMABLE THERMOSTAT 3. MERV 10 RETURN AIR FILTERS 4. ALL DUCTS SEALED WITH MASTIC TO MINIMIZE LEAKAGE 5. BATH EXHAUST FANS VENTED TO THE OUTSIDE 6. CEILING TO CEILING TRANSFER GRILLS INSULATION 1. R-9 CORE FILL 500 BLOCK INSULATION 2. R-13 UNFACED INSULATION ON 2NO FLOOR WALLS PER PLAN. 3. R30 IN ALL EXPOSED CEILINGS EXCEPT GARAGE, LANAI, ENTRY AND PATIO 4 AIR BARRIERS INSTALLED PER ENERGYSTAR THERMAL BYPASS CHECKLIST FOR IMPROVED ENERGY EFFICIENCY MTERIOR WALLS AND CEILINGS 1.12" CO CEILING BOARD ON INTERIOR CEILINGS 2. 12" DRYWALL BOARD ON ALL WALLS 3. 12' EXTERIOR CEILING BOARD ON LANAI 4. ORANGE PEEL FINISH ON ALL WALLS 5. KNOCKDOWN TEXTURE ON ALL CEILINGS 6. GARAGE BLOCK WALL TO RECEIVE DRYWALL TEXTURE 2/2012009 TOWNROM[ES Rte$ SUNRISE SERIES SPECMCAUONS CUSTOMER NAME EXTERIOR FINISH 1. TEXTURED FINISH ON BODY, SAND FINISH ON BANDING AND ACCENTS 2 SCORED LINE DETAILING ON ACCENTTRIM AREAS ROOF 1. FUNGUS RESISTANT DIMENSIONAL SHINGLES 2 METAL FLASHING 3. ROOF SHEATHING -15 LB FELT OVER 7116' ORIENTED STRAND BOARD SHEATHING 4.OFF RIDGE VENTING PER PLAN TILE 1. MASTER BATHROOM SHOWER WALL TO BE TILE TO T 0' ABOVE FINISHED FLOOR 2 GREY VEINED MARBLE WINDOW SILLS. 3.2 X 2 TILE IN SHOWER FLOOR (FIRST FLOOR ONLY) 4. CERAMIC TOWEL BARS AND PAPER -HOLDERS IN WHITE OR BISCUIT INTERIORTRIM 1. ATTIC ACCESS IN LIVING AREA TO BE GASKET SEALED WITH INSULATION BACKING 2.3 W COLONIAL BASEBOARD THROUGHOUT - PAINT GRADE 3.2 %* COLONIAL CASING -PAINT GRADE 4. FIBERGLASS INSULATED ENTRY DOORS (PER PLAN) S. PAINTED FLUSH PANEL PREHUNG DOORS WITH 2'/.' PAINT -GRADE S. PAINTED FLUSH PANEL BIFOLD DOORS 7. POLO ANTIQUE BRASS DOD KNOBS BY KWIKSET 8. FARMINGTON ANTIQUE BRASS FRONT ENTRY HANDLESET BY KWICKSET 10, PEEP HOLE IN FRONT DOOR 11. PAINTED HANDRAIL CABINETS 1. RESSECED PANEL, OAK OR MAPLE KITCHEN CABINETS (LEVEL 1) 7- 3D' WALL CABINETS IN THE KITCHEN S. LAMINATE COUNTERTOP IN THE KITCHEN, AND ALL BATHROOMS WRRORSISHELVING 1. MIRRORS OVERALL BATH VANITIES 2. TIGHMESH VINYL SHELVING IN PANTRY 3. FREE GLIDE VINYL CLOSET SHELVING IN ALL BEDROOMS AND HALL CLOSETS 4. FRAMED SHOWER ENCLOSURE IN MASTER BATH PAINT JOB s 9 N 1 19 1. COLOR WHEEL INTERIOR WHITE FLAT PAINT THRUOUGHT 2 COLOR WHEEL FLEX LOX HIGHBUILD ACRYLIC PRIMER ON EXTERIOR 3. COLOR WHEEL SATIN PAINT ON EXTERIOR CARPET 1. 'RED BUD' 24 02100% NYLON WITH STAIN SAFETY d RELEASE OVER 3B' 6B CARPET PAD (LEVEL 1) 2. VYNIL FLOORING IN FOYER, KITCHEN, ALL BATHROOMS, AND UTILITY ROOM (PER PLAN) APPLIANCES 1. GENERAL ELECTRIC JBP24 SELF CLEANING RANGE (WHITE OR BLACK) 2. GENERAL ELECTRIC GSD330ON POWER SCRUB ENERGY STAR RATED DISHWASHER (WHITE OR BLACK) 3. GENERAL ELECTRIC RON-VENTED RANGE HOOD JN327H (WHITE OR BLACK) 4. Q2 HP GARBAGE DISPOSAL LANDSCAPE 1. CUSTOM LANDSCAPING PACKAGE DESIGNED BY PROFESSIONAL LANDSCAPE CONTRACTOR PACKAGE WILL INCORPORATE COMMUNITY AND MUNICIPAL REQUIREMENTS. 2_ FLORATANWAHWST. AUGUSTINEIZOISIA SOD TO LOT LINES EXCEPT NATURAL AREAS, CONSERVATION AREAS AND PRE EXISTING DRAINAGE EASEMENTS 3. AUTOMATIC SPRINKLER SYSTEM WITH ZONE TIMER -PER CODEMIUNICIPAL REQUIREMENTS 4. MAILBOX PER COMMUNITY PLAN 5. BRICK PAVERS ON FRONT PORCH, ENTRY WALK, AM DRIVEWAY 6. ACRYLIC TOPING ON LANAI WINDOWISLIDING GLASS 1. MafSTONE 1000 SERIES LOW E IINSULATED WINDOWS 2 WHITE ALUMINUM FRAMES WITH CLEAR GLASS 3. COLONIAL WINDOWS ON FRONT ELEVATION 4. FIBERGLASS SCREENS ALL WINDOWS 5. SCREENS ON SLIDING GLASS DOORS 6. TEMPERED GLASS IN SLIDING GLASS DOORS 8.2.STORY MASTER BATH WINDOWS WILL BE CLEAR GLASS GARAGEDOORS 1.32 PANEL RAISED STEEL OVERHEAD GARAGE DOOR (DESIGN PER ELEVATION) THIS HOME WILL BE ENERGY STAR CERIFIED BYA THIRD PARTYINSPEC7/0N INACCORDANCE RWH ENERGY SW. GWDIIJNES MR HOMES, RESS?VES YHE RIGHT TO SUBS7TITlTEMATERL4LS OF EQUAL QUALITY! AIME HAVE RECEIVED A COPY OF THE "SUNRISE' SERIES SPECIFICATIONS ON THE DA7E INDICATED BELOW BUYER muYemno CBC12SS62G SELLER MA HOMES OF ORLANDO. LLC, a FloMa By. Date: Title: Area PresideM, D'nrisim PM$4i rA ar V P Sales a,d M.rketim fferx 46 04880ciateffInc. L a n d S u r v e y ors 769 Douglas Avenue, Altamonte Springs, Florida. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and American Congress on Surveying and Mapping Lot 13 Map of Survey Tract "A" Open Space, Access & Drainage N54 2231"W 190.01' i 2D' .30' .00' ZS 25. 1. a taS m:AS • m :SS? ' m 15.5 }e y"y m13Sp y, rze• Accor @an Nerd Oryrerd Grum BrantlW N54 22'31 "W 190.01' N o CJI. t1' 20.3 355.71' N54 22'31 "W 629.26' CIL Tract B" R/W Varies) Access LEGAL DESCRIPTION Lots 14, 15, 16, 17, 18, 19 & 20, 'Riverview Townhomes", according to the plat thereofas recorded in plat book 74 at pages) 46 - 53 of Me public records of Seminole Counly, Fonda. FLOOD HAZARD DATA: The parcel shown hereon ties wihiin flood zone 7(" SETBACKS: according to the Flood Insurance Rate Map community pane! number Front:21.F Side :7.17" Rear: 4.5' 120294 006O dated 9/28/2007. Flood Zone determination was performed bygraphic ploth'ng from Flood Insurance Rate Maps provided by FEMA No held surveying was performed by this firm to determine this zone. The exactzone location can only be defermined by an elevation study. We assume no responsibility foractual flooding conditions. General Notes: Pj CI P SEHI' This is a BOUNDARY Survey performed in the field on 2. No aerial, surface or subsurface utility installations, underground improvements or subsudacelaenal encroachments, itany, were located.. 3. Building ties shown are to the exterior unfinished /bundafioir3udace or formboard. 4. Elevations shown hereon, if any, are assumed and were obtained from approved Conshuction plans provided by the Client unless otherwise noted, and are shown only to depict the proposed or actual difference in elevation relative to the assumed temporary Benchmark shown hereon. 5. The parcel shown hereon is subject to all easements, reservations, restrictions, and Rights-of-way of record whether depicted or not on this document. No search of the Public Records has been made by this office. 6. The legal description shown hereon is as furnished by client. 7. Platted and measured distances and directions are the same unless otherwise noted. B. Copies of this Survey may be made for the original transaction only, s Denotes X. iron red with plastic cap marked LB4937, or %* iron rod with red plastic cap marked 'Witness Comer. unless otherwise noted. Denotes P.C.P. (Permanent control point) Denotes Permanent Reference Monument 2009 Herx & Associates Inc. AO rights reserved 273.55' BEARING BASE.'The bearings shown hereon are based upon the eastern plat boundary as being N00"f0Y)0"W. vertical datum is based on engineering plans as provided by the client, prepared by Evans Engineering, Inc., Job # 12001. Legend Lot 20 Rivervie v -• 7 -Unit T home Lot 14 m offsetOfhral Records Book 60'Deepx zr 3,113 Sq. Ft Lot 15 Sq. FL 175.66' Wide PC 1,832 F1,shedFloorEla PCC. 25.3 0 Sq. FL Lot 16 Lot q, FL2,150 Sq. Lot 13 o a3• a so 2,150 ao 123' 2,150 y Permanent Reference Mo iment CD Chord P2 N54 22'31 "W 190.01' N o CJI. t1' 20.3 355.71' N54 22'31 "W 629.26' CIL Tract B" R/W Varies) Access LEGAL DESCRIPTION Lots 14, 15, 16, 17, 18, 19 & 20, 'Riverview Townhomes", according to the plat thereofas recorded in plat book 74 at pages) 46 - 53 of Me public records of Seminole Counly, Fonda. FLOOD HAZARD DATA: The parcel shown hereon ties wihiin flood zone 7(" SETBACKS: according to the Flood Insurance Rate Map community pane! number Front:21.F Side :7.17" Rear: 4.5' 120294 006O dated 9/28/2007. Flood Zone determination was performed bygraphic ploth'ng from Flood Insurance Rate Maps provided by FEMA No held surveying was performed by this firm to determine this zone. The exactzone location can only be defermined by an elevation study. We assume no responsibility foractual flooding conditions. General Notes: Pj CI P SEHI' This is a BOUNDARY Survey performed in the field on 2. No aerial, surface or subsurface utility installations, underground improvements or subsudacelaenal encroachments, itany, were located.. 3. Building ties shown are to the exterior unfinished /bundafioir3udace or formboard. 4. Elevations shown hereon, if any, are assumed and were obtained from approved Conshuction plans provided by the Client unless otherwise noted, and are shown only to depict the proposed or actual difference in elevation relative to the assumed temporary Benchmark shown hereon. 5. The parcel shown hereon is subject to all easements, reservations, restrictions, and Rights-of-way of record whether depicted or not on this document. No search of the Public Records has been made by this office. 6. The legal description shown hereon is as furnished by client. 7. Platted and measured distances and directions are the same unless otherwise noted. B. Copies of this Survey may be made for the original transaction only, s Denotes X. iron red with plastic cap marked LB4937, or %* iron rod with red plastic cap marked 'Witness Comer. unless otherwise noted. Denotes P.C.P. (Permanent control point) Denotes Permanent Reference Monument 2009 Herx & Associates Inc. AO rights reserved 273.55' BEARING BASE.'The bearings shown hereon are based upon the eastern plat boundary as being N00"f0Y)0"W. vertical datum is based on engineering plans as provided by the client, prepared by Evans Engineering, Inc., Job # 12001. Legend Lot 20 Drawn by: CM of a Flodda npensed surveyor dldapp , Lot 19 3,114 Sq. FL m offsetOfhral Records Book 1,832 zr Ps Lot 21 Sq. FL Back of side—* PC Pool of Curvature C& Z PCC. Point of Compound Curvature 0 Central or (Delta) Angle p C.P. Permanent Comrol Point zo o 0 Page CB Tarfile, y Permanent Reference Mo iment N54 22'31 "W 190.01' N o CJI. t1' 20.3 355.71' N54 22'31 "W 629.26' CIL Tract B" R/W Varies) Access LEGAL DESCRIPTION Lots 14, 15, 16, 17, 18, 19 & 20, 'Riverview Townhomes", according to the plat thereofas recorded in plat book 74 at pages) 46 - 53 of Me public records of Seminole Counly, Fonda. FLOOD HAZARD DATA: The parcel shown hereon ties wihiin flood zone 7(" SETBACKS: according to the Flood Insurance Rate Map community pane! number Front:21.F Side :7.17" Rear: 4.5' 120294 006O dated 9/28/2007. Flood Zone determination was performed bygraphic ploth'ng from Flood Insurance Rate Maps provided by FEMA No held surveying was performed by this firm to determine this zone. The exactzone location can only be defermined by an elevation study. We assume no responsibility foractual flooding conditions. General Notes: Pj CI P SEHI' This is a BOUNDARY Survey performed in the field on 2. No aerial, surface or subsurface utility installations, underground improvements or subsudacelaenal encroachments, itany, were located.. 3. Building ties shown are to the exterior unfinished /bundafioir3udace or formboard. 4. Elevations shown hereon, if any, are assumed and were obtained from approved Conshuction plans provided by the Client unless otherwise noted, and are shown only to depict the proposed or actual difference in elevation relative to the assumed temporary Benchmark shown hereon. 5. The parcel shown hereon is subject to all easements, reservations, restrictions, and Rights-of-way of record whether depicted or not on this document. No search of the Public Records has been made by this office. 6. The legal description shown hereon is as furnished by client. 7. Platted and measured distances and directions are the same unless otherwise noted. B. Copies of this Survey may be made for the original transaction only, s Denotes X. iron red with plastic cap marked LB4937, or %* iron rod with red plastic cap marked 'Witness Comer. unless otherwise noted. Denotes P.C.P. (Permanent control point) Denotes Permanent Reference Monument 2009 Herx & Associates Inc. AO rights reserved 273.55' BEARING BASE.'The bearings shown hereon are based upon the eastern plat boundary as being N00"f0Y)0"W. vertical datum is based on engineering plans as provided by the client, prepared by Evans Engineering, Inc., Job # 12001. Legend Drawn by: CM of a Flodda npensed surveyor dldapp , a TemporaryBenchmark orsO.R.B. offsetOfhral Records Book In assumeddatum) Ps Plat Book BOW Back of side—* PC Pool of Curvature C& Cemedne PCC. Point of Compound Curvature d Central or (Delta) Angle p C.P. Permanent Comrol Point CALC Calw1ated PG. Page CB Chord Beanng P.R.M. Permanent Reference Mo iment CD Chord P2 Property Line C. M. Concrete Monument A0 B. PokdofBeginang EL." 510"llon (Proposed) P.0 C. Point of Commencement FINAL EL Elevation (Measureog PL Pw'nl of fnteisedion FD. Found PRC. Point olReverse Cunrdture Fin.FI. FJev. Finished Floor Elevation PT. Pant of Tangency I -P. IoM Pipe R Radius I.R. Iran Rod RAD Radial Line L And Length RES. Residence LB Lpensed Business R/y Right-ol-Way Ls. Land Surveyor 7BM Temporary Benchmark Mea Measured TYR Typical NJD(N&D) Nod and Disk Jr -/A. Fence symbol (see drawing) N. R. Not Radial X --X- Fence symbol isee drawing) Cennloenon: Not valid wkhout Wre and the original misedseal Drawn by: CM of a Flodda npensed surveyor dldapp , Chocked by: OP nv's survey meets the nquiremen of the F a VInimum T In Prepared for: IH//Homes Sta as romainedin Ch G17 FloridaAdmires( Code. Sketch of Legal Description Job.07.005-01 A, orm This is NOT a Survey Scalee:: 11 ""== 440' Plot Plan Performed: 01.17.09 WUiam A. Herx, P.L S. Fforda Re9Lstene rid Surveyor No. 3182 Foundation Survey: Dame L Przemieniecki, P:S. M. Regis wveyor and Mapper No, 6030 Final Herz & Associates I..., State of Fbrida 40 37 viSurvey: Revisions: , CITY OF SANFORD PERMIT APPLICATION Application # : 09-0921 Submittal Date 06/10/09 Job Address: 2567 River Landing Drive Value of Work: $ 5250.00 Parcel ID: Zoning: Historic District: Description of Work: Install 3 ton, 14 SEER system includes ductwo rs6are Footage: Permit Type: Building Electrical Mechanical Q Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential W Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair—Residential Commercial Occupancy Type: Residential Commercial Industrial Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) Property Owner: M/I Homes Contractor: One Stop Cooling & Heating, Inc. Address: 300 Colonial Center Parkway, Suite 200 Address: 669 Harold Avenue Lake Mary, FL 32746 407-531- Phone: 5100 E-mail: Bonding Company: Address: Architect/Engineer: Address: Plan Review Contact Person: Winter Park FL 32789 Phone: 407- 6 038State License Number: CA C056786 Mortgage Lender: Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional re this county, and there may be additional permits required from other govemmental Acceptance of permit is verification that I will notify the owner of Signature of Owner/Agent Print Owner/Agent's Name Signature of Notary -State of Florida Owner/Agent is P rsonally Known to Me or Produced ID APPROVALS: ZONING: Special Conditions: Rev 07.07 Date Date UTIL: FD: s applicable to this property that may be found in the public records of such as water management districts, state agencies, or federal agencies. operty 9f th 1171'\'O' i it n is of orida Lien Law, FS 713. 06/10/09 Stf e f Contractor/ Date pyehenA. Gado P ' t Contractor/Agent's Name re Y"Po,Notary Public State of Florida Diane M Jones cIc My Commission DD792564 9jF0r ,O'' Expires 07/2112012 ProducedID ENG: BLDG: D ONE STOP Cooling and Heating, Inc. 669 Harold Avenue, Winter Park, FL 32789 407) 629.6920 Fax (407) 629.9307 CAC056786 March 23, 2009 City of Sanford Building Department 300 N. Park Avenue Sanford, FL 32771 To Whom It May Concern: This letter is to confirm we have been contracted by M/I Homes to install the HVAC for Riverview Town homes. Riverview, Lot 18, 2567 River Landing Drive, BP# 09-0921, Castine Model has the contract amount of $5250.00. If you have any questions or problems, please contact me. Thank you. Very truly yours, ONEtW HEATING, INC. M/I HO ' ', L I-X Vv SO4A. Brad W' tman/ President VP of Constructi n STATE OF FLORIDA\ - COUNTY OF ORANGE The foregoing instrument was acknowledged this 30th day of March, 2009, by Stephen A,.. Gadoury and Brad Wightman, who are personally known to me. V. fir_ = otiPsY P`# Notary Public state of Florida Diane Jones Diane M JonesQMyCommission DD792564 Expires 07/21/2012: 7/21 /2012 669 Harold Avenue, Winter Park, FL 32789 407) 629-6920 Fax (407) 629-9307 CAC056786 POWER OF ATTORNEY I hereby name and appoint Nicole Wissinger to be my lawful attorney in fact to act for me and apply to the City of Sanford building department for a mechanical permit for work performed at a location described as: M/I Homes: Riverview, Lot 18, 2567 River Landing Drive; BP#09-0921 And sign my name and do all things necessary to this appointment. Stephen X. GadoVr77 C056786 STATE OF FLORIDA COUNTY OF: Oranqe I The fo going inst me t was acknowledged this 10th day of June , 2009 , by s,,, , who is personally known to me. Diane Jones Jones te of Florida N c c D792564or"d-2 fferx * eaffgocifftege Land Surveyors 769 Douglas Avenue, Altamonte Springs, Florida. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and American Congress on Surveying and Mapping Map of Survey PERMIT # Z7 DATE: z Tract 'A" Open Space, Access & Drainage N54 022'31 "W 190.01' CIL Tract "B" R/W Varies) Access LEGAL DESCRIPTION Lots 14, 15, 16, 17, 18, 19 & 20, "Riverview Townhomes , according to the plat thereof as recorded in plat book 74 at page(s) 46- 53 of the public records of Seminole County, Flonda. FLOOD HAZARD DATA: The parcel shown hereon lies within flood zone X" according to the Flood Insurance Rate Map community panel number 120294-006OF dated 9/28/2007. Flood Zone determination was performed by graphic plotting from Flood Insurance Rate Maps provided by FEMA. No field surveying was performed by this firm to determine this zone. The exact zone location can only be determined by an elevation study. We assume no responsibility for actual flooding conditions. General Notes: pp1. This is a BOUNDARY Survey performed in the field on 11 ,p/tO /pD SED. 2. No aerial, surface or subsurface utility installations, underground improvements or subsurface/aerial encroachments, if any, were located. 3. Building ties shown are to the exterior unfinished foundation surface or formboard. 4. Elevations shown hereon, if any, are assumed and were obtained from approved Construction plans provided by the Client unless otherwise noted, and are shown only to depict the proposed or actual difference in elevation relative to the assumed CITY OF SANFORD - BUILDING PLAN REVIEW PLANNING AND DEVELOPMENT SERVICES APPROVED A.M 42, DATE 2 -4-1-- -6' . SETBACKS.- Front: ETBACKS. Front: 21.5' Side : 7.17" Rear: 4.5' BEARING BASE. -The bearings shown hereon are based upon the eastem plat boundary as being N00"10'00"W. Vertical datum is based on engineering plans as provided by the client, prepared by Evans Engineering, Inc., Job # 12001. Legend Z 2 r o 19.2' a 013.5' v"r y 155' " r y 155' 9, i."r 13.5• o o 19.2' 9, .'r 27. W BOW Back of sidewalk PB Uc C/L Centerline 7.8' 9.5' 12.8' 27' 115 9.5' 7.8' 10.2' U110.2' Calculated P.C.P. Q CB Astor BranBord Castine Dryford Castro Branfrord Astor 0 V4oRiverviev - 7 -Unit Tc wnhome o 112 Lot 14 60' Deep x Lot 20 CO 3,113 Sq. Ft. Lot 15 175.66' Wide Lot 19 3,114 Sq. FL 1i Lot 13 27' 1,832 F ishedFloor t 17 25.3 1,832 2.r Lot 21 O y Sq. Ft. Lot 16 2,150 Sq. Ft. Lot 18 Sq• Ft. v, 00 2.7' 8.3' a0 2,150 5o Sq. Ft. 4.0' 12.3' 12.0 2,150 Sq. FL 50 8.3' o 2.7 9) O13.0' O 0 W N 0 4 N 13.0' ff W p O y 18.0' 11.3' 20.0' 20.0' o.T 11.3' 18.0' 10' Utilit ase 77ent M25' N 36.20' 21. 0' 5.00' 25.00' 2130' 36.21' N54 022'31 "W 190.01 ' O Manhole o CIC EL: 24.3 ri 355.71' 273.55' 1 N54 °22'31 "W V 629.26' CIL Tract "B" R/W Varies) Access LEGAL DESCRIPTION Lots 14, 15, 16, 17, 18, 19 & 20, "Riverview Townhomes , according to the plat thereof as recorded in plat book 74 at page(s) 46- 53 of the public records of Seminole County, Flonda. FLOOD HAZARD DATA: The parcel shown hereon lies within flood zone X" according to the Flood Insurance Rate Map community panel number 120294-006OF dated 9/28/2007. Flood Zone determination was performed by graphic plotting from Flood Insurance Rate Maps provided by FEMA. No field surveying was performed by this firm to determine this zone. The exact zone location can only be determined by an elevation study. We assume no responsibility for actual flooding conditions. General Notes: pp1. This is a BOUNDARY Survey performed in the field on 11 ,p/tO /pD SED. 2. No aerial, surface or subsurface utility installations, underground improvements or subsurface/aerial encroachments, if any, were located. 3. Building ties shown are to the exterior unfinished foundation surface or formboard. 4. Elevations shown hereon, if any, are assumed and were obtained from approved Construction plans provided by the Client unless otherwise noted, and are shown only to depict the proposed or actual difference in elevation relative to the assumed CITY OF SANFORD - BUILDING PLAN REVIEW PLANNING AND DEVELOPMENT SERVICES APPROVED A.M 42, DATE 2 -4-1-- -6' . SETBACKS.- Front: ETBACKS. Front: 21.5' Side : 7.17" Rear: 4.5' BEARING BASE. -The bearings shown hereon are based upon the eastem plat boundary as being N00"10'00"W. Vertical datum is based on engineering plans as provided by the client, prepared by Evans Engineering, Inc., Job # 12001. Legend G Temporary Benchmark 0/S Offset assumed datum) O.R.B. Official Records Book BOW Back of sidewalk PB Plat Book C/L Centerline PC Point of Curvature dCentral or (Delta) Angle PCC. Point of Compound Curvature CALC Calculated P.C.P. Permanent Control Point CB Chord Bearing PG. Page p P Ad P. --e Anrmm-. AA-' f Project Name: RV 18, Unit C 2299 NE Builder: MI Homes Address: a 0 I j Win, n ;,. ; Permitting Office: Sanford City, State: `,1eT v( til Permit Number: Owner: MI Homes Jurisdiction Number: 691500 Climate Zone: Central 1. New construction or existing New _ 2. Cooling systems 2. Single family or multi -family Multi -family _ Central Unit/Spli /J Cap: 32.1 IcBtu/hr 3. Number of units, if multi -family I 9 # 4. Number of Bedrooms 4 - 5. Is this a worst case? No _ f'U . 6. Conditioned floor area (ft') 2299 ftZ c. N/A 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U -factor: Description Area 13. Heating syst ms or Single or Double DEFAULT) 7a. (Dble, U=0.7) 155.0 ftz _ a. Electric Heat p/Split Cap: 32.7 kBtu/hr b. SHGC: HSPF: 8.50 _ or Clear or Tint DEFAULT) 7b. (SHGC=0.67) 155.0 ftz _ b. N/A 8. Floor types a. Raised Wood R=13.0, 402.0 ft' _ c. N/A b. Slab -On -Grade Edge Insulation, 0 R=0.0, 88.0 ft' c. I Others 43.0 ftz _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 50.0 gallons a. Concrete, Int Insul, Exterior R=9.0, 283.0 ft' _ EF: 0.95 _ b. Frame, Wood, Adjacent R=13.0, 219.0 ft' _ b. N/A c. Frame, Wood, Exterior R=13.0, 435.0 ftz d. Concrete, fnt Insul, Adjacent R=9.0, 192.0 ftz _ c. Conservation credits e. Concrete, Int Insul, Exterior R=9.0, 208.0 ftZ _ HR -Heat recovery, Solar. 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 52.0 It 15. HVAC credits PT, _ b. Under Attic R=30.0, 1398.0 ft2 _ CF -Ceiling fan, CV -Cross ventilation, c. N/A HF -Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Una AH(Sealed):Interior Sup. R=6.0, 200.0 ft MZ -C -Multizone cooling, b. N/A MZ -H -Multizone heating) Glass/Floor Area: 0.07 Total as -built points: 21746 PASS c Total base points: 27694 PAS I hereby certify that the plans and specifications covered by this calculation are in compliapce with the Florida Energy Code. PREPARED BY: /Z T l DATE: I hereby certify that this building, s desi hed, is in with the Florida Energy Co OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCPB v4.5.2) O4-THE ST4l O.r Uuld $. CiM MIOFSAWFORDPERT APPLICATION Application # : _ q2_1 Submittal Date: 1}- If3 s G 7 , I Job Address: 11 (. n ! ! 4 Fi c- Value of Work: $ Parcel ID' Zoning: Historic District: Description of Work: i 4.)winc_ Footage: II Permit Type: Building E3Electrical Mecbani I I I I Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service - # of AMPS = Addition/Altmation Change of Service Temporary Pole Mechanical: Residential Non -Residential Q Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial• # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential O Commercial Occupancy Type: Residential Commercial . Industrial Occupancy Use Group(s}: Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) I ...................• ........................•.......................,16................... 4.........• ....... Property Owner: Contractor:NL. ._ L4.+1'1C. Address:wo Colon al Ctnkv- R Address: L 3aT1 o v 1 a>n c1In- Phone:-aal: P#ore: -1 lei State License Number: Eck 3( l gllp Bonding Company: Address: ArchitecVEagineer: Address: Plan Review Contact Person: Mortgage Lender: Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work Will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that an of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zor img WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CAO&MENCENIENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR -PROPERTY. A -NOTICE OF CONI lENCE AENT MUST -BE -RECORDED AND POSTED -ON TIIE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. A:cceptartc^e of permit is verification dw i will notify the owner of the property of uircments of Florida Lien Law, FS 713. Signature of Owner/Agent Date SiTAatam of; Contractor/Agent Date Print O mer/Agent's Name Contractor/Agent's Name 6 Signature of Nagy -State of Florida Dde :sure of Notary -State of FloridaY Po, Notary Public State of Florida tp Brian Walewski 1-1- 144 e` My Commission DD621809 of ° Expires 02124/2011 Owner/Agent is — Personally Known to Me or Contractor/Agent isersonaliy Known to Men Produced ilk Produeed 11) APPROVALS: ZONING: UTIL: FD: Special Conditions: Rev 07.07 ENG: BLD€'r.. a 0 r' CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No:---- Q9— 9Q_1 Documented Construction Value: $ 6 -Li (P ' `' 1 QE IAddress: yI Historic District: Yes No Parcel ID: Description of Work: Plan Review Contact Person: Phone: Fax: Zoning: Title: E-mail: Property Owner Information Name "'l Street: 3 -CO upknn ul Ceyitcir PI(p City, State Zip: Lckt FL_3L 1 ` '% p Phone: —LM 5 31 t) [63 Contractor Information t of property? : Name P k MC Phone: 4M `i i1) u Street: JD—1Fax: 4Q1 4t Q OW -3 City, State Zip: 51( cL' ca State License No.: Cl::_c C)s S S Name: Street: City, St, Zip: Bonding Company: Address: Building Permit Square Footage: No. of Dwelling Units: Electrical New Service — No. of AMPS: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing New Construction - No. of Fixtures: Mechanical 0 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: l I Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: COMMENTS: Rev 11.08 ENGINEERING: nature Contractor/Agent Date PCIU 1 Print Contractor/Agent's Name Signature of Notary -State of Florida Date UTILITIES: FIRE: KRISTIE SANFORD NOTARY PUBLIC - STATE OF FLORIDA COMMISSION # DD477357 EXPIRES 10/02/2009 BONDED THRU 1-888-NOTARY1 Contractor/Agent is Personally Known to Me or Produced ID Type of ID WASTE WATER: BUILDING: sBordeau One Stop Plumbing Inc. Price For Above $4,10352 3o% Rough In $1,231.o6 3o% Tub Set $1,231.o6 4o% Trim $1,641.41 564 Cooper Commerce Drive Apopka F132703 Office 407-410-o16o Fax 407-410-o163 CFC057555 Standard Proposal Date November 7, 2008 Contractor MI Homes Plan/Model Unit C) Castine Select One Brantford or Eva Ouantity Each Total Master Bath Up 1 Elongated Water Closet W/ Seat MB up Lav 2 23.83 4766 2 See Selection Sheet for Lav and Faucet Lav Faucet 6610 or 6410 2 77.87 155.74 1 See S.S. for Shower base W/ See Selection Sheet for Valve and Shower Trim Shower Base JS368969 1 37749 37749 Shower Trim & Valve 2152 or 2132 1 86.56 86.56 Hall Bath Up 1 Elongated Water Closet W/ Seat HB 2 Lav 1 23.83 2383 1 Sec Selection Sheet for Lav and Faucet Lav Faucet 6610 or 6410 1 7787 77.87 Left 1 See Selection Sheet for Tub W/ See Selection Sheet for Valve and Tub Trim 5' Steel Tub 1 141.56 141.56 Tub Trim & Valve 2153 or 2133 1 102.48 102.48 Hall Bath Dn 1 Elongated Water Closet W/ Seat 1 See Selection Sheet for Lav and Faucet PB Ped Lav 20x18 1 96.78 9678 1 See S.S. for Shower base W/ See Selection Sheet for Valve and Shower Trim Lav Faucet 6610 or 6410 1 7787 7787 Shower Base JS368969 1 37749 37749 Water Heater 1 See Selection Sheet for Water Heater Shower Trim & Valve 2152 or 2132 1 86.56 86.56 1 Sewer Connection o' To 30' WH 55 gallon 1 33267 332.67 1 4" AC Chase 2 Quick bib w/ cap @ tubset/ Hose Bibb W/ 3/4" Vacuum Breaker on trim 1 1" PVC Water Service o' to 30' 1 Thermal Expansion Device Kitchen 1 See Selection Sheet for Kitchen Sink and Faucet Kit. 1 Dishwasher Connection w/ Shock Arrestor 33x22 6" deep SS 1 44.78 4478 1 Ice Maker Box w/ LOOP to kitchen w/ shock arrestors Chateau K/Faucet 7430 1 83.61 83.61 1 1/2 Hp Disposal on Right 1 Studer vent @ kitchen Total Trim Options: 2,112.95 Laundry Up 1 Washingmachine Box w/ shock arrestors & Pan w/ C PVC Drain u .47 Total w/Std Fixtures Price For Above $4,10352 3o% Rough In $1,231.o6 3o% Tub Set $1,231.o6 4o% Trim $1,641.41 564 Cooper Commerce Drive Apopka F132703 Office 407-410-o16o Fax 407-410-o163 CFC057555 U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency Management Agency Expires March 31, 2012 National Flood Insurance Program Important: Read the instructions on pages 1-9. SECTION A -PROPERTY INFORMATION $For Insurarc Company=Use Al. Building Owner's Name M/I Homes A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC NuM,66.131 2567 River Landing.Drive Z3g Wiz` Citv Sanford State FI ZIP Code 32772 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 18 Riverview Townhomes, Plat Book 74 Pages 46-53 Seminole County, Florida A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 28°48'47.5" Long -81°17'49.0" Horizontal Datum: NAD 1927 E NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) 0 sq ft a) Square footage of attached garage 402 sq ft b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage enclosure(s) within 1.0 foot above adjacent grade 0 within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0 sq in c) Total net area of flood openings in A9.b 0 sq in d) Engineered flood openings? Yes - ® No d) Engineered flood openings? Yes ® No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State City of Sanford & 120294 Seminole County FI B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone 120117CO060 F Date Effective/Revised Date Zone(s) AO, use base flood depth) feet meters (Puerto Rico only) 9/28/2007 9/28/2007 X N/A B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. FIS Profile FIRM Community Determined Other (Describe) N/A B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 NAVD 1988 Other (Describe) N/A B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes ® No Designation Date CBRS OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: Construction Drawings' Building Under Construction* ® Finished Construction A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, ARAE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. Use the same datum as the BFE. Benchmark Utilized Seminole County BM8095501Vertical Datum NAVD 88 Conversion/Comments Note Construction Engineering plans are based upon NGVD 1929. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 24.5 feet meters (Puerto Rico only) b) Top of the next higher floor 35.2 feet. meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) N/A. feet meters (Puerto Rico only) d) Attached garage (top of slab) 24.2 feet meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building 23.9 feet meters (Puerto Rico only) Describe type of equipment and location in Comments) 0 Lowest adjacent (finished) grade next to building (LAG) 23.7 feet meters (Puerto Rico only) g) Highest adjacent (finished) grade next to building (HAG) 23.9 feet meters (Puerto Rico only) h) Lowest adjacent grade at lowest elevation of deck or stairs, including N/A. feet meters (Puerto Rico only) structural support SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. / certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001. Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a 0111, licensed land surveyor? ® Yes El No - Certifier's Name Darae L. Przemieniecki License Number PSM 6030 Title Professional Surveyor and Mapper Company Name Herx & Associates, Inc. Address 769 Dougl Ave a City Altamonte Springs State FI ZIP Code 32714 Sign ure , - Date 08-20-09 Telephone 407-788-8808 FEMA Form 81-31, Mar U9 See reverse side for continuation. Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number.= ; 2567 River Landing Drive City Sanford State FI ZIP Code 32772 Company'NAIC Nimber-,.'r" SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. CommentsItem C2e r rs to Conditioner slab elevation. Flood Zone was determi ed by gr hic plotting on NMA Flood Insurance Rate Maps. Associates, nc. um no responsibility Hactual flooding conditions. 4`fY\/Vt Signature Date 08-20-09 Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is feet meters above or below the HAG. b) Top of -bottom floor (including basement, crawlspace, or enclosure) is feet meters above or below the LAG. E2. For Building Diagrams 6-9 with permanentfloodopenings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor elevation C2.b in the diagrams) of the building is feet meters above or below the HAG. E3. Attached garage (top of slab) is feet meters above or below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is - feet meters above or below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? Yes No Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E) and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 and G9. G1. The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) p 9G2. A, community official completed Section E for a"buildin located in Zone A without aFEMA-issued or community -issued BFE) br'Zohe AO:--` `- - - G3. The following information (Items G4 -G9) is provided for community floodplain management purposes. G4. Permit Number I G5. Date Permit Issued I G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: New Construction Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: feet meters (PR) Datum G9. BFE or (in Zbne AO) depth of flooding at the building site: feet meters (PR) Datum G10. Community's design'fl,00d'elevation Local Official's Name Title feet meters (PR) Datum Community Name: Telephone Signature. - Date Comments Check here if attachments FEMA Form 81-31, Mar 09 Replaces all previous editions Building Photographs See Instructions for Item A6. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 2567 River Landing Drive City Sanford State FI ZIP Code 32772 Company NAIC; Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page on the reverse. Front View Building Photographs Continuation Page For Insurance Company, Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 2567 River Landing Drive City Sanford State FI ZIP Code 32772 Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." Rear View Herx & Associates Inc. 769 Douglas Avenue Altamonte Springs, Florida 32714 407.788.8808 - 407.788.8762 (fax) August 20, 2009 City of Sanford Building Division P.O. Box 1788 Sanford, Florida 32772-1788 RE: Lot 18 Riverview Townhomes, 2567 River Landing Drive To Whom It May Concern, The finished floor elevation of the structure located at: 2567 River Landing Drive, Sanford, Florida Legal Description: Lot 18, "RIVERVIEW TOWNHOMES", according to the Plat thereof, as recorded in Plat Book 74 at pages 46 through 53 Public Records of Seminole County, Florida. Meets or exceeds the requirements set forth in the City of Sanford Code Chapter 18, sections 18-4(a). Sincetely,Yours, Hetx & Associates Inc. Da.rae L. Przemieniecki ` .M Associate Vice President DLP/bb Lot 13 Land Surveyors 769 Douglas Avenue, Altamonte Springs, Florida. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and American Congress on Surveying and Mapping 5i W V J h v Map of Survey Tract 'A" Open Space, Access & Drainage h N54 °22'31 "W 190.01' ` 20:: tens 3:: 25. ... 5. 1. taeel ? f3.5'min L.nal m 15.5' o renal::: m 155' m tam v H m 13.5'9 t. 0m19.2' m- 19.2' m ram 0 0 72200 10.2' - o 78' - y 9.5. 12.8' 2r 11.5' 9.5' 7.8' 10.2' Astor Brantloni Castine Diyford Castine Brentford Astor o w Rivervie v - 7 -Unit Te wnhome Lot 14 3,113 Sq. FL Lot 15 F Vshed Floor El 25.7 Lot 19 Lot 20 3,114 Sq. Ft. 2,7' 1,832 Lot 17 1,832 2.7 rEnIn aN Sq. Ft. Lot 16 2,150 Sq. Ft. Lot 18 Sq. Ft. a7-71y 2.7' 8.3' a 2, 150 50 4.0' 12.3' 2,150 a 8.3' 2. 0j13.0' Sq. Ft. 12.o'J20. 13.0" wS:+ m o " 0.7' N o 0 20.0' or I 18.0'11.3' 18.0' 10' Utilit aseme 21.30' 25.00' 25.0 21.30' Pet NBD J 1054 "LL'J 7 V NSD I' t t o po 0 Set `O CIL EL 2Q'\I355.71' NeD 1 P N54 °22'31 "W 629.26' aybeck courtCIL River Landing Drive RM Varies) Tract "B"Access LEGAL DESCRIPTION Lots 14, 15, 16, 17, 18, 19 & 20, "Riverview Townhomes", according to the plat thereof as recorded in plat book 74 at page(s) 46 - 53 of the public records of Seminole County, Florida. FLOOD HAZARD DATA: The parcel shown hereon lies within flood zone 'X" according to the Flood Insurance Rate Map community panel number 120294-006OF dated 9/28/2007. Flood Zone determination was performed by graphic plotting from Flood Insurance Rate Maps provided by FEMA. No field surveying was performed by this firm to determine this zone. The exact zone location can only be determined by an elevation study. We assume no responsibility for actual flooding conditions. SETBACKS: Front:21.5' Side :7.17" Rear:4.5' Lot 21 273.55' e/ PCP BEARING BASE: The bearings shown hereon are based upon the eastern plat boundary as being N00°10'00"W. Vertical datum is based on engineering plans as provided by the client, prepared by Evans Engineering, Inc., Job # 12001. General Notes: , o- 1. This is a BOUNDARY Survey performed in the field on Legend 0/S Offset 2. No aerial, surface or subsurface utility installations, underground improvements or G Temporary Benchmark O.R.B. Official Records Book subsurface/aerial encroachments, if any, were located. (assumed datum) PB Plat Book 3. Building ties shown are to the exterior unfinished foundation surface or formboard. BOW Back of sidewalkCILCenterline PC Point of Curvature 4. Elevations shown hereon, if any, are assumed and were obtained from approved PCC. Point of Compound Curvature Constructionlans provided by the Client unless otherwise noted, and are shown d Central or (Delta) Angle P. C. P. Permanent Control Point P P CALC Calculated PG. Page only to depict the proposed or actual difference in elevation relative to the assumed CB Chord Bearing P.R.M. Permanent Reference Monument temporary Benchmark shown hereon. CD Chord PA- Property Line 5. The parcel shown hereon is subject to all easements, reservations, restrictions, and C. M. Concrete Monument P.O.B. Point of Beginning Rights-of-way of record whether depicted or not on this document. No search of the EL. or ELEV Elevation (Proposed) P.O.C. Point of Commencement Public Records has been made by this office. FINAL EL. Elevation (Measured) P.I. Point of Intersection 6. The. legal description shown hereon is as furnished b Client. FD. Found PRC. Point of Reverse Curvature 9 P Y Fin.Fl. Elev. Finished Floor Elevation PT Point of Tangency7. Platted and measured distances and directions are the same unless otherwise noted. I.P. Iron Pipe 8. Copies of this Survey may be made for the original transaction only. I.R. Iron Rod R Radius P Y Y 9 Y RAD Radial Line Denotes/:" iron rod with plastic cap marked LB4937, or 'z" iron rod with L Arc Length RES. Residence red plastic cap marked "Witness Comer", unless otherwise noted. LB Licensed Business RAW Right -of -Way O Denotes P.C.P. (Permanent control point) LS. Land Surveyor TBM Temporary Benchmark Denotes Permanent Reference IV1011 Ument Mea Measured TYP. Typical N/D(N&D) Nail and Disk Fence symbol (see drawing) 2009 Herx & Associates Inc. All rights reserved N.R. Not Radial -X-X- Fence symbol (see drawing) Certification: kot valid witl o t the ' nature end the Lative seal Drawn by: CM of a Florida licensed Surrey and Ma per Checked by: DP This survey meets the requirem nts of th Florida Minimu Prepared for: M11 Homes Standards as contained in,;;ba r 1161 -5 Florida Adrni Job Number: 07-005-01 Scale: 1"= 40' Plot Plan Performed: 01-12-09 William A. Herx, P.L. S. Florida R3gis14NdLandSuveyorNo, 3182 Foundation Survey: 03-12-09 Darae L. Przemieniecki, P.S.M. Regist d Surveyor and Mapper No. 6030 Final Survey: 08-13-09 Herx & Associates inc., State of Florida LB 4937 cS " 17 -Q Revisions: