Loading...
HomeMy WebLinkAbout1101 WP Ball Blvd (a), ,Y �Y� 't �+: ,.' ,a °. ^u4 Vit. ,A;I.M1.. i"�". ,J, ` ,14 <<: . �+°M t,.i,.,i"! r1' `->i�urd: ?r. r,r�1Ai _ � y��. 4,. t�+n�Y:. �. a.;o "�,,-2•dr� a�. Interior Modification for Vacant SPace # 1 101 Marketplace at Seminole Towne Center 1101 WP BALL BLVD. SANFORD FL 32771 ABBREVIATIONSWW. PROVISIONS OF CHAPTER 6 FOR LEVEL I ALTERATIONS AS WELL AS A PROTECTED I UN -PROTECTED 2001- FLORIDA BUILDING CODE, MECHANICAL OCCUPANT LOAD: PER TABLE 1004.1 STORIES 4 4 MercanRle (M) 21,500 12,500 200'1- FLORIDA BUILDING CODE, PLUMBING 2008- NATIONAL ELECTRIC CODE MERCANTILE TA5LE 601 HARDWOOD NA NOT APPLIICABLE $/A SUPPLY AIR ABV: ABOVE DIM. DIMENSION HDII HARDWARE NATFINW NATURAL FINISHED WOOD S.A.C. SUSPENDED ACOUSTICAL CLG ADJ. ADJUSTABLE DN. DOWN N.C. HANDICAPPED N.I.C. NOT IN CONTRACT S.C. SOLID CORE AFF. ABOVE FINISHED FLOOR DR, = 01 WC HP NAVY DUTY NONCOM- NONCOMBUSTIBLE S.C. SHOPPING: CENTER AL. ALUMINUM DS H,EAC. HANDICAPPED E=. KTA NOT TO SCALE SECT SECTION ALUM. ALUMINUM DWG. = 02 LAY NM" HOLLOW METAL 0 O SF. SQUARE FOOT ANOD. ANODIZED OW DRAWER NOR HORIZONTAL O.C. ON CENTER SLDR SLIDING DOORS APPROX. APPROXIMATE WATER HEATER = 01 HORZ. HORIZONTAL OD. OVERFLOW1 DRAIN SIM. SIMILAR ARCH. ARCHITECT EA HORIZ. HORIZONTAL OD. OUTSIDE DIAMETER SPEC. SPECIFICATIONS ARCH. ARCHITECTURAL E•IFS• = 16 404,2 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE = 160 PS (PEOPLLE SERVED) = 12 F"U HIGH POINT OD. OUTSIDE DIMENSION SMR. SPRINKLER BB. BULLETIN BOARD E.J. ELEC. FIXTURES HR HOUR OADOOR OVERHEAD DOOR Sa SQUARE BD. BOARD ELEV FIXTURES HR 14ANG94IL OPNG. OPENING S.S. STAINLESS STEEL BLDG. BUILDINGS EL ELEVATION = 29"5 F.U. DIGHT OPP OPPOSITE S.S. SERVICE SINK BLK BLOCK Ea EQUAL. HGT. HEIGHT OPP. HND. OPPOSITE HAND STRUCT. STRUCTURAL BLKG BLOCKING EQUIP. STRUC" STRUCTURAL BM- BEAM INSIDE DIMENSION +/- PLUS OR MANUS STD. STANDARD BO. BY OTHERS EWIV. ESCAL. ID. INSIDE DIAMETER PART PARTIAL STL. STEEL BOT" BOTTOM E111L. NGAND. INCANDESCENT PART/N PARTITION ST.STL. STAINLESS STEEL INSULATED, INSULATION PL. PLATE SUSP SUSPENDED EXG. EXISTING INT INTERIOR FLAK PLASTIC LAMINATE CAB CABINET EM. EXTERIOR PLYWD. PLYWOOD TA TOILET ACCESSORY C.H. CEILING HEIGHT JAN. JANITOR PLWD. PLYWOOD TC TOP OF CURB CLG" CEILING FD. FLOOR DRAIN JOIST PN-" PANEL TEL TELEPHONE CLR CJ CEILING CLEAR F.E. F,E.C. FIRE EXTINGUISHER FIRE EXTINGUISHER AND CABINET LAMD.PLAS. LAMINATED PLASTIC POL• POLISHED THK THICK CENTERLINE FAC. FIRE HOSE CABINET LH LEFT -NAND PM�-� POLISHED 'PLATE GLASS TAS. TOP OF STEEL CD" CLEAN OUT FIN. FINISH LL LANDLORD PAS. PONT OF SALE T or TRD. TREAD CM CONCRETE MASONRY UNIT FIXT FIXTURE PREFAB. P.S.F. PREFABRICATED PONDS PER SQUARE FOOT TR TYTp, TIME RECORDER TYPICAL COL. COLUMN FL FLOOR L.L.V. LONG LEG VERTICAL PT. PONT COL LACa COLORED LACQUER FLR FLOOR LP. LOW PONT PT. PAINT UN.O. UNLESS NOTED OTWRWISE CONST. CONSTRUCTION FLUOR FLUORESCENT M MIRROR PTD PAINTED CONT. CONTINUOUS FR FITTING ROOM MAS. MASONRY V.C.T. VINYL COMPOSITION TILE CONTR. CONTRACTOR F.S. FULL SIZE MAT'L. MATERIAL R RISER VERT. VERTICAL CONC. CONCRETE FTG. FOOTING MAX. MAXIMUM RIA RETURN Alia VEST. VESTIBULE GR CASH REGISTER MEC_ MECHANICAL REF" REFERENCE V.I.F. VERIFY IN FIELD CR PL. CHROMIUM PLATE GA. GAUGE MEP MECH, ELECTRICAL, PLUMBING REINF. REINFORCED CT CERAMIC TILE GALV. GALVANIZED MET. METAL REMV REMOVEABILE W/ WITH DBL. DOUBLE G.C. ORAL CONTRACTOR MFR MANAFAGTURER REQ'D REQUIRED W/O WITHOUT DEG. DEGREE GFRG" GLASS FIBER REINF. CONC. MGR MANAGER REV REVISION UC. WATER CLOSET DEPT. DEPARTMENT C44 GARMENT HANGER MIN. MINIMUM RD. ROOF DRAIN W.C. WALL COVERING DIA DIAMETER G.I. GALVANIZED IRON MISG. MISCELLANEOUS F4I RIGWT-HAND WD" WOOD DITTO THE SAME - REPEAT GL GLASS MD. MASONRY OPENING Ift ROOM WDTK WIDTH PTL. DETAIL GYP. BD. GYPSUM BOARD MTL METAL RO. ROUGH OPENING WAIF. WELDED WIRE FABRIC DF DRINKING FOUNTAIN GYP. GYPSUM hMOUNTED IAM DIAMETER MTD.. MFR STANDARD GAUGE OCCUPANCY: "M" MERCANTILE LOCATION MAP SCAM: NTS BUILDING AND CONSTRUCTION CODE DATA APPLICAME CODE INFORMATION BUILDING TYPE CLASSIFICATION TABLE 501 AND TABLE 601 AND 602 DATA WITH THE 2009 SUPPLEMENTS TYPE OF CONSTRUCTION: TYPE II (B) UN -PROTECTED FULLY SPRINKLER TA5LE 503 REQU 2001- FLORIDA BUILDING CODE BUILDING OCCUPANCY: MERCANTILE OCCUPANCY - GROUP M PROVISIONS OF CHAPTER 6 FOR LEVEL I ALTERATIONS AS WELL AS A PROTECTED I UN -PROTECTED 2001- FLORIDA BUILDING CODE, MECHANICAL OCCUPANT LOAD: PER TABLE 1004.1 STORIES 4 4 MercanRle (M) 21,500 12,500 200'1- FLORIDA BUILDING CODE, PLUMBING 2008- NATIONAL ELECTRIC CODE MERCANTILE TA5LE 601 REQUIREMENTS - FLORIDA ENERGY EFFICIENCY CODE FOR BLDG CONSTR BASEMENT AND GRADE FLOOR AREAS 30 gross TABLE 403.1 MINIMUM NUMPER OF REQUIRED PLUM51NG FIXTURE5 TYPE II (B) A B ENERGYGAUGE SUMMIT FLA/COM-2008, EFFECTIVE: STORAGE, STOCK, SHIPPING AREAS 300 gross MARCH I, 2009 - FORM 40OA-2008 BUSINESS AREAS 100 gross OFFICE AREA- NON PUBLIC AREAS 1,600 GROSS SQ. FT BIG LOTS PROVIDED PUBLIC FIXTURES (EXISTING) 2001- FLORIDA FIRE PREVENTION CODE STRUCTURAL FRAME A 852 OCCUPANTS / 2 = 426 PER SEX MENS 2001- EXISTING FLORIDA BUILDING CODE OCCUPANT LOAD INCLUDING COLUMNS, GIRDERS, TRUSSES 1 0 2 01 WC 2001- UNDERWRITERS LABORATORIES INC STORAGE AREA 24 OCC BEARING WALLS 1 O = 01 WC 2006- NFPA-101 LIFE SAFETY CODE WITH FLORIDA AMENDMENTS OFFICE AREA- NCI PUBLIC AREAS 16 OCC EXTERIOR WATER CLOSETS -----------------= 1/500 LAV" - PROVIDED = 02 LAV FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS PRODUCT APPROVAL RESTROOM -EXIT HALLWAY 03 OCC INTERIOR LAVATORIES ---------------------= 1/150 WOMENS EGRESS WIDTH: MERCANTILE SPACE SALE AREA MERCANTILE SPACE 809 OCC NONBEARING WALLS AND PARTITIONS See table 602 See table 602 = 02 WC 852 OCC. x 02"/OCG, 110" MINIMUM REQUIRED EGRESS WIDTH TOTAL OCCUPANCY 852 OCC EXTERIOR DRINKING FOUNTAIN ------------ = 1/1000 LAV. - PROVIDED = 02 LAY PR FULL BREAKAWAY DOORS PROVIDED AT MAIN ENTRANCE 150"/02 ALTERATION LEVEL: NONBEARING WALLS AND PARTITIONS 0 O = 01 HIGH = 150 PS ( PEOPLE SERVED) PER EXISTING BUILDING CODE FBC 2001 INTERIOR E MALE 426 FEMALE 426 SERVICE SINK = 01 PR FULL BREAKAWAY DOORS PROVIDED At MAIN ENTRANCE 150"/02 404.1 SCOPE" LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF FLOOR CONSTRUCTION 1 d O d h = 150 PS ( PEOPLE SERVED) SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE INCLUDING SUPPORTING BEAMS AND JOISTS PUBLIC FIXTURES REQUIRED WATER HEATER = 01 DOORS PROVIDED At FRONT WALL 32" /02 RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE THE STORY OR SPACE COMPLIES WITH SECTION 1015.1 AS A SPACE WITH FLOOR DRAINS = 02 = 16 INSTALLATION OF ANY ADDITIONAL EQUIPMENT. = 160 PS l PEOPLE SERVED) ROOF CONSTRUCTION 1 0� DOORS PROVIDED At REAR ENTRANCE 32" /02 INCLUDING SUPPORTING BEAMS AND JOISTS W.G. = 1 WC W.C. = 1 WC UNIT COUNT (EXISTING) � 30 ALL O WATER CLOSET 4 FSI 03 = 16 404,2 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE = 160 PS (PEOPLLE SERVED) Y -O" DOORS PROVIDED At REAR ENTRANCE 32" /02 PROVISIONS OF CHAPTER 6 FOR LEVEL I ALTERATIONS AS WELL AS i 01-26-10 = 160 PS ( PEOPLE SERVED) THE PROVISIONS OF CHAPTER I. P 01-10-11 BULLETIN NO 1 TOTAL EGRESS WIDTH PROVIDED EQUALS 386" BUILDING OCCUPANCY: OCCUPANCY - MERCANTILE "M" TABLE 403.1 MINIMUM NUMPER OF REQUIRED PLUM51NG FIXTURE5 STORAGE 1235 GROSS SQ" FT OFFICE AREA- NON PUBLIC AREAS 1,600 GROSS SQ. FT BIG LOTS PROVIDED PUBLIC FIXTURES (EXISTING) RESTROOM -EXIT HALLWAY 138 GROSS SQ. FT 852 OCCUPANTS / 2 = 426 PER SEX MENS SALE AREA MERCANTILE SPACE 24,269 GROSS SQ. FT W.C. - PROVIDED 2 01 WC TOTAL MERCANTILE SPACE 33,842 GROSS SQ" Ft REQUIREMENTS MERCANTILE URN - PROVIDED = 01 WC BUILDINGS DESCRIBED IN TABLE 10192, PROVIDED THAT THE BUILDING WATER CLOSETS -----------------= 1/500 LAV" - PROVIDED = 02 LAV HAS NOT MORE THAN ONE LEVEL BELOW LAVATORIES ---------------------= 1/150 WOMENS „I. THE FIRST STORY ABOVE GRADE PLANE. SERVICE SINK --------------------= -- W.C. - PROVIDED = 02 WC DRINKING FOUNTAIN ------------ = 1/1000 LAV. - PROVIDED = 02 LAY 2. BUILDINGS OF GROUP R-3 OCCUPANCY. DRINKING FOUNTAIN = 01 HIGH /LOW MALE 426 FEMALE 426 SERVICE SINK = 01 3. SINGLE -LEVEL BUILDINGS WITH THE OCCUPIED SPACE AT THE LEVEL OF EXIT DISCHARGE PROVIDED THAT PUBLIC FIXTURES REQUIRED WATER HEATER = 01 THE STORY OR SPACE COMPLIES WITH SECTION 1015.1 AS A SPACE WITH FLOOR DRAINS = 02 ONE MEANS OF EGRESS. MENS WOMENS W.G. = 1 WC W.C. = 1 WC UNIT COUNT (EXISTING) TRAVEL DISTANCE LAY = I LAY LAV = I LAV WATER CLOSET 4 FSI 03 FIXTURES = 12 F"U A, BD, D, EE, F, M, U I STORY 49 OCCUPANTS URINAL 3 F.0 01 FIXTURES = 03 F.0 AND 15 FEET TRAVEL, DISTANCE LAV 2 F.0 04 FIXTURES = 08 F.0 D. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SERVICE SINK = 00 FL DRAINS 2 F.0 02 FIXTURES = 04 F.0 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9033.1.1 WITH DRINKING FOUNTAIN = Ol HIGH /LOW DRINKING FOUNTAIN D5 01 FIXTURES =A5 F"U AN OCCUPANCY IN GROUP B SHALL HAVE A MAXIMUM TRAVEL WATER HEATER = 01 SERVICE SINK 2 FU 01 FIXTURES = 02 F.0 DISTANCE OF 100 FEET. TOTAL: = 29"5 F.U. 10313 COMMON PATH OF TRAVEL. IN GROUP M BUILDINGS WHICH ARE SPRINKLERED THROUGHOUT, A COMMON PATH OF TRAVEL NOT EXCEEDING 100 FEET (30 480 MM) SHALL BE PERMITTED. 1016.1 TRAVEL DISTANCE LIMITATIONS EXIT ACCESS TRAVEL DISTANCE PER TABLE 1016.1 OCCUPANCY TYPE " M " WITH SPRINKLER SYSTEM 250 FEET TABLE 50833 REQUIIRED SEPRATION OF OCCUPANCIES (HOUR) FOR BUSINESS AND MERCANTILE - N (NO SEPRATION REQUIRED) 108.1 GENERAL. THE FOLLOWING WALL ASSEMBLIES SHALL COMPLY WITH THIS SECTION: I. WALL SEPARATING INDIVIDUAL TENANT SPACES. 1083 FIRE -RESISTANCE RATING. FIRE PARTITIONS SHALL HAVE A FIRE - RESISTANCE RATING OF NOT LESS THAN I HOUR REFER TO SHEET A003 4 A004 FOR UL DETAILS AND SPECIFICAITION SECTION 1210 SURROUNDING MATERIALS 12102 WALLS. WALLS WITHIN 2 FEET (610 MM) OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE, t0 A HEIGHT OF 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. 12105 TOILET ROOMS, TOILET ROOMS SHALL NOT OPEN DIRECTLY INTO A ROOM USED FOR THE PREPARATION OF FOOD FOR SERVICE t0 THE PUBLIC. 410.1 DRINKING FOUNTAINS SHALL CONFORM TO ASME A112.1 -11M, ASME A112.192M OR ASME A112J9.9M AND WATER COOLERS SHALL CONFORM t0 ARI 1010. DRINKING FOUNTAINS AND WATER COOLERS SHALL CONFORM t0 NSF 61, SECTION S. WHERE WATER IS SERVED IN RESTAURANTS, DRINKING FOUNTAINS SHALL NOT BE REQUIRED. IN OTHER OCCUPANCIES, WHERE DRINKING FOUNTAINS ARE REQUIRED, WATER COOLERS OR BOTTLED WATER DISPENSERS SHALL BE PERMITTED TO BE SUBSTITUTED FOR NOT MORE THAN 50 PERCENT OF THE REQUIRED DRINKING FOUNTAINS. B UN -PROTECTED 1 EXISTING PROVIDED B See table 602 0 0d h 0 ALL 403.2 SEPARATE FACILITIES. WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE FACILITIES SHALL BE PROVIDED FOR EACH SEX. EXCEPTIONS: I. SEPARATE FACILITIES SHALL NOT BE REQUIRED FOR DWELLING UNITS AND SLEEPING UNITS. 2. SEPARATE FACILITIES SHALL NOT BE REQUIRED FOR FOOD SERVICE ESTABLISHMENTS WHICH SEAT 10 PERSONS OR LESS. I SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL FLOOR AREA OF 3,000 SQUARE FEET (219 M2) OR LESS. Parcel ID: 32-19-30-503-0000-0070 LEGAL DESCRIPTION: LOT 7 THE MARKETPLACE AT SEMINOLE TOWNE CENTER PB 67 PGS 72 - 74 CONTACT LIST CLIENT:- LANDLORD WE INGARTEN REALTY 2120 EAST COLONIAL DRIVE ORLANO, FLORIDA 328®3 P:401-563-1125 CONTACT: VALE MENNINGER E-MAIL: ®MENNINGEROWEINGARTEN.COM TENANT: BIG LOTS STORES, INC. STORE PLANNING DEPT. 300 PHILL1101 ROAD COLUMBUS, OHIO 43228 PHONE: (614) 218-6WO ARCHITECT: J. HOWARD NUDELL ARCHITECT 500 WINDERLEY PLACE - SUITE 220 MAITLAND, FLORIDA 32151 P: 401-140-8022 F: 401-140-6322 CONTACT: S CHRISTOPHER TORCHIA E-MAIL CTORCHIA6JHN.COM STRUCTURAL/ELECTRICAL /MECHANICAL ENGINEERS: RBE CONSULTING SERVICES, LLC 2815 SPLIT OAK COURT OVIEDO, FL 32166 P: 401-196-3820 - STRUCTURAL P: 401-366-3505 - MECHANICAL/PLUMBING P:401-611-3113 - ELECTRICAL F: 401-911-6118 CONTACTS: ROBERT BEATTIE E-MAIL: R5EATTIE6R5ECS.COM NARSIM SHAH E-MAIL: NSHAH-@RBECS.COM FERNANDO AMIL151A E-MAIL: FAMILIBIA,@RBECS.COM r ire pr6v . 1 SITE PLAN _ SCALE: NTS 11 DRAWING r INDEX • • l l i 01-26-10 . • , .01-10-11 P 01-10-11 BULLETIN NO 1 01-28-11 ` w • ' UL DETAILS r • DEMOLITION N• Fix A2 FIXTURE PLAN - SCHEbULES AND DETAILS rx IA5 TOILET ROOM PLAN AND DETAILS ELECTRICAL EO ELECTRICAL SYM5OLS, LEGEND$ AND NOTES E5 EMS CONTROLS AND SKCIFICATIONS FAI FIRE ALARM SYSTEMS PLANS FIRE PROTECTION v J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maltland, Florida 32751 t: 407.740,5022 t 407.740.8322 OFFIM fN Fam ftton H ft MM pan 248 324 8800 Ddo Texas 972 387 5900 d w°a Lill; NOTICE THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GNEN IN CONFIDENCE. NO USE, IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF NUDELL ARCHITECTS ALL W; -HTS ARE HEREBY SPECIFICALLY RESERVED, DELL ARCHITECTS COPYRIGHT YEAR 2011 State of Florida Registered Architect A,� rn r- - Sri n• Joel Ht#yel Reg, No, 7953 project title WEINGARTEN REALTY Interior Modification for In Marketplace at Seminole Towne Center OCCUPANCY: Mercantile "M" Retail I I 7701 WP Ball Blvd & Towne Center Blvd I I Sanford Florida 32771 sheet title COVER SHEET INDEX -LOCATION MAP - CODE W NOT SCALE DRAWINGS USE FIGUFED DIMENSIONS ONLY project number 2010-160 drawn checked SCT approved CM issued for date TENANT APPR 01-26-10 BIDDING ISSUE , .01-10-11 P 01-10-11 BULLETIN NO 1 01-28-11 sheet riffin'rhe LIFE SAFETY PLAN SCALE: 1/8" = 1'-0" IDESPAN WIDESPAN WIDESP N or I=MMIMMMI lmmmlmmm IMMMIMMIMI LIFE SAFETY LEGEND PEOPLE SERVED xxx xxx =CLEAR EXIT WIDTH (IN INCHES) MAX. TRAVEL DISTANCE TO EXIT OR EXIT �® ACCESS DOOR AS PER SECTION 1004.1 (INCLUSIVE EXCEPTION 1004.1.4) ® EXIT LIGHTS FE FIRE EXTINGUISHERS -TYPE 2AI05C 1 _ 1 \ H.G. CLEARANCE L_t APPLIGAIBLE CODE INFORMATION WITH THE 2009 SUPPLEMENTS 2001- FLORIDA BUILDING CODE 2001- FLORIDA BUILDING CODE, MECHANICAL 2001- FLORIDA BUILDING CODE, PLUMBING 2008- NATIONAL ELECTRIC CODE - FLORIDA ENERGY EFFICIENCY CODE FOR BLDG CONSTR ENERGYGAUGE SUMMIT FLA/COM-2008, EFFECTIVE: MARCH I, 2009 - FORM 40OA-2008 2001- FLORIDA FIRE PREVENTION CODE 2001- EXISTING FLORIDA BUILDING CODE 2001- UNDERWRITERS LABORATORIES INC 2006- NFPA-101 LIFE SAFETY CODE WITH FLORIDA AMENDMENTS FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS PRODUCT APPROVAL EGRESS WIDTH: MERCANTILE SPACE 852 OCC. x 02"/OCG. 110" MINIMUM REQUIRED EGRESS WIDTH PR FULL BREAKAWAY DOORS PROVIDED AT MAIN ENTRANCE 150"/02 = 150 PS ( PEOPLE SERVED) PR FULL BREAKAWAY DOORS PROVIDED AT MAIN ENTRANCE 150"/02 = 150 PS ( PEOPLE SERVED) 3'-0" DOORS PROVIDED AT FRONT WALL 32" /02 = 160 PS ( PEOPLE SERVED) 3'-0" DOORS PROVIDED AT REAR ENTRANCE 32" /02 = 160 PS ( PEOPLE SERVED) 3'-0" DOORS PROVIDED AT REAR ENTRANCE 32" /02 = 160 PS ( PEOPLE SERVED) TOTAL EGRESS WIDTH PROVIDED EQUALS 386" BUILDING OCCUPANCY: OCCUPANCY - MERCANTILE "M" STORAGE 1,235 GROSS SQ. FT OFFICE AREA- NON PUBLIC AREAS 1,600 GROSS SQ. FT RESTROOM -EXIT HALLWAY 138 GROSS SQ. FT SALE AREA MERCANTILE SPACE 24,269 GROSS SQ. FT TOTAL MERCANTILE SPACE 33,842 GROSS SQ. FT 1016.1 TRAVEL DISTANCE LIMITATIONS EXIT ACCESS TRAVEL DISTANCE PER TABLE 1016.1 OCCUPANCY TYPE " M " WITH SPRINKLER SYSTEM 250 FEET BUILDING TYPE CLASSIFICATION TYPE OF CONSTRUCTION: TYPE II (B) UN -PROTECTED FULLY SPRINKLER BUILDING OCCUPANCY: MERCANTILE OCCUPANCY - GROUP M OCCUPANT LOAD: PER TABLE 1004.1 30 gross300 gross MERCANTILE 100 gross BASEMENT AND GRADE FLOOR AREAS STORAGE, STOCK, SHIPPING AREAS BUSINESS AREAS OCCUPANT LOAD STORAGE AREA 24 OCC OFFICE AREA- NON PUBLIC AREAS 16 OCC RESTROOM -EXIT HALLWAY 03 OCC SALE AREA MERCANTILE SPACE 809 OCC TOTAL OCCUPANCY 852 OCC ALTERATION LEVEL: PER EXISTING BUILDING CODE FBG 2001 404.1 SCOPE. LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. 4042 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 6 FOR LEVEL I ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 1. EXIT CRITERIA PER FBC 2001 SECTION 1005 EGRESS WIDTH THE MEANS OF EGRESS WIDTH SHALL NOT BE LESS THAN REQUIRED BY THE 2001 FLORIDA BUILDING CODE. THE TOTAL WIDTH OF MEANS OF EGRESS IN INCHES SHALL NOT BE LESS THAN THE TOTAL OCCUPANT LOAD SERVED BY THE MEANS OF EGRESS MULTIPLIED BY 02 INCHES PER OCCUPANT AND NOT LESS THAN SPECIFIED ELSEWHERE IN THE FBG CODE. MULTIPLE MEANS OF EGRESS SHALL BE SIZED SUCH THAT THE LOSS OF ANY ONE MEANS OF EGRESS SHALL NOT REDUCE THE AVAILABLE CAPACITY TO LESS THAN 50 PERCENT OF THE REQUIRED CAPACITY. THE MAXIMUM CAPACITY REQUIRED FROM ANY STORY OF A BUILDING SHALL BE MAINTAINED TO THE TERMINATION OF THE MEANS OF EGRESS. DOOR ENCROACHMENT. DOORS OPENING INTO THE PATH OF EGRESS TRAVEL SHALL NOT REDUCE THE REQUIRED WIDTH TO LESS THAN ONE-HALF DURING THE COURSE OF THE SWING. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 1 INCHES (116 MM) INTO THE REQUIRED WIDTH. J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maltiand, Florida 32751 t 407.740.8022 t 407.740.8322 OFFICES IN Fam*Ol n H111% MlcFdgen 248 324 8800 Dales Texas 972 387 5900 NOTICE THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GIVEN IN CONFDENCE . NO USE, IN WHOLE OR PART, MAY BE MADE WITHOUT PRIM WRITTEN CONSENT OF NUDELL ARCHITECTS, ALL RIGHTS ARE HEREBY SPECIFICALLY RESERVED, NUDELL ARCHITECTS COPYRIGHT YEAR 2011 State of Florida Registered Architect NTE►Irri��f� 0�= w C. "y/(,''y�'•�. • til ``� Joel Ndi��dell Reg. No, 7953 project title I nn TEREALTY yy Interior Modification for LOTSIF is In Marketplace at Seminole Towne Center OCCUPANCY: Mercantile "M" Retail I I 1101 WP Ball Blvd & Towne Center Blvd I I Sanford Florida 32771 sheet title LIFE SAFETY PLAN AND NOTES r•���' tie " project number 2010-160 drawn SCT checked SGT aDoroved CM issued for SEASONAL BULK TENANT APPR 01-26-10 PIppING ISSUE Z iV 01-10-11 BULLETIN NO 1 W v IDESPAN WIDESPAN WIDESP N or I=MMIMMMI lmmmlmmm IMMMIMMIMI LIFE SAFETY LEGEND PEOPLE SERVED xxx xxx =CLEAR EXIT WIDTH (IN INCHES) MAX. TRAVEL DISTANCE TO EXIT OR EXIT �® ACCESS DOOR AS PER SECTION 1004.1 (INCLUSIVE EXCEPTION 1004.1.4) ® EXIT LIGHTS FE FIRE EXTINGUISHERS -TYPE 2AI05C 1 _ 1 \ H.G. CLEARANCE L_t APPLIGAIBLE CODE INFORMATION WITH THE 2009 SUPPLEMENTS 2001- FLORIDA BUILDING CODE 2001- FLORIDA BUILDING CODE, MECHANICAL 2001- FLORIDA BUILDING CODE, PLUMBING 2008- NATIONAL ELECTRIC CODE - FLORIDA ENERGY EFFICIENCY CODE FOR BLDG CONSTR ENERGYGAUGE SUMMIT FLA/COM-2008, EFFECTIVE: MARCH I, 2009 - FORM 40OA-2008 2001- FLORIDA FIRE PREVENTION CODE 2001- EXISTING FLORIDA BUILDING CODE 2001- UNDERWRITERS LABORATORIES INC 2006- NFPA-101 LIFE SAFETY CODE WITH FLORIDA AMENDMENTS FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS PRODUCT APPROVAL EGRESS WIDTH: MERCANTILE SPACE 852 OCC. x 02"/OCG. 110" MINIMUM REQUIRED EGRESS WIDTH PR FULL BREAKAWAY DOORS PROVIDED AT MAIN ENTRANCE 150"/02 = 150 PS ( PEOPLE SERVED) PR FULL BREAKAWAY DOORS PROVIDED AT MAIN ENTRANCE 150"/02 = 150 PS ( PEOPLE SERVED) 3'-0" DOORS PROVIDED AT FRONT WALL 32" /02 = 160 PS ( PEOPLE SERVED) 3'-0" DOORS PROVIDED AT REAR ENTRANCE 32" /02 = 160 PS ( PEOPLE SERVED) 3'-0" DOORS PROVIDED AT REAR ENTRANCE 32" /02 = 160 PS ( PEOPLE SERVED) TOTAL EGRESS WIDTH PROVIDED EQUALS 386" BUILDING OCCUPANCY: OCCUPANCY - MERCANTILE "M" STORAGE 1,235 GROSS SQ. FT OFFICE AREA- NON PUBLIC AREAS 1,600 GROSS SQ. FT RESTROOM -EXIT HALLWAY 138 GROSS SQ. FT SALE AREA MERCANTILE SPACE 24,269 GROSS SQ. FT TOTAL MERCANTILE SPACE 33,842 GROSS SQ. FT 1016.1 TRAVEL DISTANCE LIMITATIONS EXIT ACCESS TRAVEL DISTANCE PER TABLE 1016.1 OCCUPANCY TYPE " M " WITH SPRINKLER SYSTEM 250 FEET BUILDING TYPE CLASSIFICATION TYPE OF CONSTRUCTION: TYPE II (B) UN -PROTECTED FULLY SPRINKLER BUILDING OCCUPANCY: MERCANTILE OCCUPANCY - GROUP M OCCUPANT LOAD: PER TABLE 1004.1 30 gross300 gross MERCANTILE 100 gross BASEMENT AND GRADE FLOOR AREAS STORAGE, STOCK, SHIPPING AREAS BUSINESS AREAS OCCUPANT LOAD STORAGE AREA 24 OCC OFFICE AREA- NON PUBLIC AREAS 16 OCC RESTROOM -EXIT HALLWAY 03 OCC SALE AREA MERCANTILE SPACE 809 OCC TOTAL OCCUPANCY 852 OCC ALTERATION LEVEL: PER EXISTING BUILDING CODE FBG 2001 404.1 SCOPE. LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. 4042 APPLICATION. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 6 FOR LEVEL I ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 1. EXIT CRITERIA PER FBC 2001 SECTION 1005 EGRESS WIDTH THE MEANS OF EGRESS WIDTH SHALL NOT BE LESS THAN REQUIRED BY THE 2001 FLORIDA BUILDING CODE. THE TOTAL WIDTH OF MEANS OF EGRESS IN INCHES SHALL NOT BE LESS THAN THE TOTAL OCCUPANT LOAD SERVED BY THE MEANS OF EGRESS MULTIPLIED BY 02 INCHES PER OCCUPANT AND NOT LESS THAN SPECIFIED ELSEWHERE IN THE FBG CODE. MULTIPLE MEANS OF EGRESS SHALL BE SIZED SUCH THAT THE LOSS OF ANY ONE MEANS OF EGRESS SHALL NOT REDUCE THE AVAILABLE CAPACITY TO LESS THAN 50 PERCENT OF THE REQUIRED CAPACITY. THE MAXIMUM CAPACITY REQUIRED FROM ANY STORY OF A BUILDING SHALL BE MAINTAINED TO THE TERMINATION OF THE MEANS OF EGRESS. DOOR ENCROACHMENT. DOORS OPENING INTO THE PATH OF EGRESS TRAVEL SHALL NOT REDUCE THE REQUIRED WIDTH TO LESS THAN ONE-HALF DURING THE COURSE OF THE SWING. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 1 INCHES (116 MM) INTO THE REQUIRED WIDTH. J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maltiand, Florida 32751 t 407.740.8022 t 407.740.8322 OFFICES IN Fam*Ol n H111% MlcFdgen 248 324 8800 Dales Texas 972 387 5900 NOTICE THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GIVEN IN CONFDENCE . NO USE, IN WHOLE OR PART, MAY BE MADE WITHOUT PRIM WRITTEN CONSENT OF NUDELL ARCHITECTS, ALL RIGHTS ARE HEREBY SPECIFICALLY RESERVED, NUDELL ARCHITECTS COPYRIGHT YEAR 2011 State of Florida Registered Architect NTE►Irri��f� 0�= w C. "y/(,''y�'•�. • til ``� Joel Ndi��dell Reg. No, 7953 project title I nn TEREALTY yy Interior Modification for LOTSIF is In Marketplace at Seminole Towne Center OCCUPANCY: Mercantile "M" Retail I I 1101 WP Ball Blvd & Towne Center Blvd I I Sanford Florida 32771 sheet title LIFE SAFETY PLAN AND NOTES r•���' tie " project number 2010-160 drawn SCT checked SGT aDoroved CM issued for date TENANT APPR 01-26-10 PIppING ISSUE 01-10-11 PERMIT ISSUE 01-10-11 BULLETIN NO 1 01-28-11 sheet LSPOO PAD MOUNTED TRANSFORMER FURNISHED BY UTILITY CO. EX. OUTSIDE METER CT NEX.CABINET EX. 4#600kcmil, 4"C., EACH (EXISTING) 4#600kcmil, 4"C., EACH (EXISTING) /- 225A M.L.O 400A M.L.O SLP L P O 1 SLP L -- PANEL "L" PANEL "PP" EX. 4#600kcmil, 1#3G 3-1/2"C. (EXISTING) 4#3/0, 1 #6G., 2 TO TO BUILDING UNDERGROUND STEEL WATER PIPE SEE EMS PLANS SHEET E-4 & E-5 PANEL MDP Q 800A, M.L.O EX. 3#350kcmil, 1#4G., 3"C (EXISTING) 4#350kcmil, 1#4G., 3"C (EXISTING) ' --� EX. #3/0 COPPER GROUNDING =_ ELECTRODE CONDUCTORS (2) 5/8" CU. CLAD GROUNDING RODS 6' APART & 8' DEEP PAD MOUNTED DRY TYPE TRANSFORMER 225kVA 480-120/208V 3-PHASE EX. UNNUMBERED NOTES APPLY TO THIS SCHEDULE IN A GENERAL SENSE. NUMBERED NOTES APPLY TO A SPECIFIC CIRCUMSTANCE WHERE INDICATED AND TAKE PRECEDENCE OVER UNNUMBERED NOTES WHERE A CONFLICT EXISTS BETWEEN THE TWO. AMPACITY VALUES ARE BASED ON 2008 NEC TABLE 34-16 USING COPPER CONDUCTORS WITH 75 DEGREE C INSULATION IN A MAXIMUM AMBIENT OF 30 DEGREES C. CONDUIT SIZES ARE BASED ON 2008 NEC CHAPTER 9, TABLES 4 AND 5, AND THE USE OF CONDUCTORS WITH TYPE THWN INSULATION. GROUNDING CONDUCTOR SIZES ARE BASED ON 2008 NEC TABLE 250-94 USING THE AMPACITY VALUE SHOWN. ALL CONDUCTOR SIZES SHOWN ARE THE MINIMUM ACCEPTABLE SIZE TO SATISFY AMPACITY REQUIREMENTS. SIZES OF CONDUCTORS AND RACEWAYS SHALL BE INCREASED TO COMPENSATE FOR VOLTAGE DROP AND INSULATION SCCR WHERE NECESSARY. VERIFY THAT ALL MATERIALS ACTUALLY USED MATCH DIMENSIONS, CAPACITIES, ETC .. . OF ALL ASSUMED VALUES AND MAKE ANY NECESSARY ADJUSTMENTS BEFORE USING THIS SCHEDULE. RISER DIAGRAM NOTES O1 EXISTING SERVICE TRANSFORMER WITH 277/48OV, 3PH, 4W SECONDARY AND SOLIDLY GROUND NEUTRAL. O REFER TO PANEL SCHEDULE FOR CALCULATION FOR REVISED CIRCUITRY. O EXISTI 2"C - METERING BY P R CO. ® ENERGY METERING DEVICE. SEE SHEETS E-4 AND E-5 FOR DETAILS. PANEL DP 0 800A, M.C.B TO TO UNDERGROUND BUILDING WATER PIPE STEEL EXISTING MAIN SERVICE RISER DIAGRAM 4#3, 1#6G., 1-1/4--C (EXISTING) 225A M.L.O 225A M.L.O 225A M.L.O 0 Q PANEL "A" PANEL "B" PANEL "B" X. I X. EX. 4#3/0, 1#6G.! 2"C EX. NOTE: ALL EQUIPMENT SHOWN IS EXISTING TO REMAIN, UNLESS OTHERWISE NOTED. ALL EQUIPMENT NOT SHOWN IS EITHER TO BE DEMOLISHED OR HAS BEEN ALREADY REMVOED. FIELD VERIFY PRIOR TO ANY REMOVAL OF GEAR. EOlMEW SPECIFICATIONS - DMSION SMIE01 SEMINOLE TOWNE CENTER - BIG LOTS DATE: 01 /08/11 EQUIPMENT DESCRIPTION VOLTS PH NEUT MOTOR ADDITIONAL HEAT VN LARGEST MOTORS STRIPS H.P. FLA H.P. FLA KW AMPS MISC AMPS TOTAL AMPS PNL C.B. SIZE DISCONNECT STARTER WIRE PER PHASE NEUT WIRE GND WIRE # OF RUNS CONDUIT SIZE NOTES SIZE FUSE SIZE TYPE RTU -1 480 3 N 1 64.0 64 80 100 N.F. PERMITTED USAGE: #4 B. NFPA 101 LIFE SAFETY CODE #8 1 1" C. STANDARD BUILDING CODE RTU -2 480 3 N 64.0 64 1 80 101 N.F. #4 8 1 1" A. RTU -3 480 3 N 40.0 40 50 60 N.F. COPIERS OF COMPLETE DESCRIPTIVE DATA ON ALL EQUIPMENT 8 10 1 3/4" 1. IN LONG RACEWAYS FURNISH AND INSTALL THE PROPER RTU -4 480 3 N 12.0 12 15 30 N.F. 12 12 1 1/2' RTU -5 480 3 N 16.0 16 35 60 N.F. WIRE AND CABLES 10 RECORD DRAWINGS 10 1 1/2" RTU -6 480 3 N 13.0 13 20 30 N.F. 12 12 1 1/2n 1.03 RTU -7 480 3 N 13.0 13 20 30 N.F. THE WORK OF THIS SECTION INCLUDES FURNISHING OF 12 AND DISTRIBUTION 12 1 1/2' RTU -8 480 3 N 24.0 24 30 30 N.F. 10 1.01 10 1 1/2" RTU -9 480 3 N 32.0 32 40 60 N.F. DISCONNECT SWITCHES #8 THE DRAWINGS ARE PARTLY DIAGRAMMATIC AND DO #10 1 3/4" NOT SHOW IN DETAIL ALL REQUIRED FEATURES OF THE BAILER 480 3 N 1 1 24.0 24 1 30 30 N.F.10 _4 10 1 1/2* SCHEDULES. APPROVED MANUFACTURERS ARE GENERAL ELECTRIC, I I I I I PART 2 PRODUCTS 2.02 DISCONNECT SWITCHES 2.01 (1) - PROVIDE DISC. SW. AT ALL PIECES OF EQUIPMENT, UNLESS OTHERWISE NOTED ON THIS SCHEDULE. (2) - FUSES SHOWN FOR REFERENCE ONLY, PROVIDE FUSES AS RECOMMENDED BY EQUIP. MANUF. (3) - PROVIDE NEMA OUTDOOR RATED ENCLOSURES FOR ALL DISC. SWS MOUNTED OUTDOORS. (4) - COORDINATE STARTER TYPE WITH MECHANICAL EQUIPMENT INSTALLER. (5) - E.C. TO VERIFY THAT C.B. FOR COMPRESSORS IS SUFFICIENT TO ALLOW STARTING OF UNIT, IF REQUIRED FOR STARTING C.B. TO BE INCREASED TO A MAX OF 225% OF COMP. F.L.A. (6) - #12 FEEDERS SHOWN AND OVER 50FT. LONG TO BE #10 WIRE FOR 120V CIRCUITS. 12 FEEDERS SHOWN AND OVER 10OFT. LONG TO BE #10 WIRE FOR 277V CIRCUITS. (a) - CONNECT VIA LINE VOLTAGE T'STAT. (b) - CONNECT VIA CONTROL DEVICES BY DIV. 15 CONTRACTOR. (c) - CONNECT VIA VFD BY DIV. 15 CONTRACTOR. (d) - CONNECT VIA STARTER BY DIV. 15 CONTRACTOR. (e) - CONNECT VIA DISC. SW. BY DIV. 15 CONTRACTOR. (f) - PROVIDE FULL SIZE NEUTRAL. (g) - MMS WITHOUT OVERLOADS. (h) - CONNECT VIA STARTER IN MCC (BY DIV. 16) (i) - CONNECT VIA HOOD CONTROL SYSTEM. 0) - CONNECT VIA STARTER FURNISHED WITH EQUIPMENT. (k) - INSTALL AND CONNECT CONTROL SWITCHES FURNISHED WITH EQUIP. ABBFEIAAUM N.F. = NON-FUSED MCP = MOTOR CIRCUIT PROT. W/ COMB. STARTER I = NEMA I ENCLOSURE MMS = MAN. MTR. STARTER SW. W/ O.L. AND PILOT 3R = NEMA 3R ENCLOSURE VFD = VARIABLE FREQ. DRIVE UNIT. 4SS = NEMA 4 W.P. STAINLESS STEEL ENCL GENERAL NOTES 1. COORDINATE INSTALLATION OF NEW ELECTRICAL SERVICES WITH LOCAL ELECTRIC UTILITY COMPANY. PROVIDE WEATHERHEADS, CONDUIT, METER BASE AND OTHER ITEMS AS REQUIRED. 2. VERIFY ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT. PROVIDE CIRCUITS AND FUSES SIZED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATION. 3. MAINTAIN CODE REQUIRED WORKING CLEARANCE AT ALL ELECTRICAL PANELS, DISCONNECT SWITCHES AND STARTERS. THERE SHALL BE NO EQUIPMENT, PIPING OR DUCT WORK INSTALLED IN OR ABOVE THE WORKING CLEARANCES. 4. PROVIDE DISCONNECT SWITCHES FOR ANY HARDWIRED EQUIPMENT NOT SUPPLIED WITH DISCONNECTING SWITCHES. 5. CONNECT AUTOMATIC TIMERS SWITCHES, CONTROLLING THE SAME CIRCUIT, IN PARALLEL SUCH THAT WHEN EITHER SWITCH IS ACTIVATED THE LIGHTING CIRCUIT OPERATES UNTIL BOTH TIMERS HAVE TURNED OFF. 6, CONNECT EXIT LIGHTS AND INCADESCENT EMERGENCY LIGHTS WITH INTERGRAL BATTERY TO LOCAL AREA LIGHTING CIRCUIT AHEAD OF THE SWITCHING SUCH THAT THEY AUTOMATICALLY CONVERT TO BATTERY OPERATION UPON LOSS OF NORMAL POWER. 7. PROVIDE CONTROL POWER SOURCE FOR ALL STATERS AND CONTROL PANELS NOT SUPPLIED WITH CONTROL PANEL TRANSFORMERS. INSTALL AND CONNECT ALL CONTROL DEVICES IN ACCORDANCE WITH MANUFACTURER'S RECOMMEDATION. 8. CONNECT EXHAUST FAN TO LIGHT FIXTURE IN SAME SPACE SUCH THAT THEY ARE SWITCHED TOGETHER. BRANCH CIRCUIT WIRING NOTES= VOLTAGE DROP COMPLIES WITH A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD. (FBC 13-413.1.ABC.1.2 BRANCH CIRCUITS.) 1. WIRING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES OR SPECIAL CONDITIONS. 2. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL OUTLETS INDICATED WITH CIRCUIT NUMBERS AND PANEL DESIGNATIONS. 3. ALL SWITCH CONTROLS SHALL BE PROVIDED WITH WIRING AND CONDUIT AS REQUIRED. 4. ALTHOUGH ALL BRANCH CIRCUIT WIRE AND CONDUIT IS NOT SHOWN, IT IS INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED. 5. PROVIDE A GREEN GROUND CONDUCTOR IN ALL CIRCUITS, APPROPRIATELY SIZED INCREASE CONDUITS TO ACCOMMODATE GROUND CONDUCTOR. 6. UNLESS SHOWN OTHERWISE (BRANCH CIRCUITING INSTRUCTIONS): 1600 WATTS MAXIMUM PER 20A/1 P BRANCH CIRCUIT, A. UNLESS SHOWN OTHERWISE. B. 6 CONY. OUTLETS MAXIMUM PER 20A/1 P BRANCH CIRCUIT. DEMOLITION NOTES 1.) EXISTING OUTLET BOXES AND CONDUIT WHICH ARE LOCATED PROPERLY FOR NEW WORK MAY BE REUSED FOR NEW DEVICES AND WIRE. 2.) ALL CONDUIT AND WIRE REMOVED SHALL BE TAKEN BACK TO THE SOURCE OF SUPPLY. 3.) INSTALL A BLANK COVER PLATE WHERE REQUIRED. 4.) VISIT THE JOB SITE PRIOR TO BID TO VERIFY ALL ACTUAL CONDITIONS. 5.) ALL FIXTURES, DEVICES, ETC., SHALL BE REMOVED UNLESS OTHERWISE NOTED. 6.) REMOVE EXISTING SYSTEMS, MATERIALS, AND EQUIPMENT WHICH ARE MADE OBSOLETE OR WHICH INTERFERE WITH THE CONSTRUCTION OF THE PROJECT. REINSTALL ANY SUCH SYSTEMS, MATERIALS, AND EQUIPMENT WHICH IS REQUIRED TO COMPLETE THE PROJECT. 7.) WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR CHANGED, ALL BRANCH CONDUITS, WHICH NO LONGER ARE IN SERVICE, SHALL BE REMOVED AS DIRECTED BY THE OWNER. IF, IN THE COURSE OF THE WORK, OUTLETS ARE COVERED UP OR OTHERWISE RENDERED INACCESSIBLE, ALL WIRING TO SAME SHALL BE REMOVED TO THE SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS INTERRUPTED THEREBY, IT SHALL BE RECONNECTED BY THE MOST INCONSPICUOUS MEANS SO AS TO REMAIN OPERATIONAL, WITH SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED AND OPENINGS LEFT BY REMOVAL OF BOXES, PIPING, OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. ALL HOLES LEFT IN JUNCTION BOXES, SWITCHES, PANELS, ETC., SHALL BE CLOSED. 8.) WHERE NEW OPENINGS ARE CUT AND CONCEALED CONDUITS, ETC., ARE ENCOUNTERED, THEY SHALL BE REMOVED OR RELOCATED AS REQUIRED. WHERE CONDUIT TO BE REMOVED STUBS THROUGH FLOORS, WALLS, AND CEILINGS, SUCH CONDUIT SHALL BE REMOVED TO THE POINT WHERE THE FINISH SURFACES CAN BE PATCHED ADEQUATELY SO THAT NO EVIDENCE OF THE FORMER INSTALLATION REMAINS. 9.) ALL REUSABLE DEVICES, FIXTURES, AND EQUIPMENT SHALL BECOME THE PROPERTY OF THE OWNER. ALL OTHER SALVAGE AND DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY. MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE AND SHALL BE IN ACCORDANCE WITH THE REFERENCE STANDARDS listed above. C. MAKE POWER CONNECTIONS TO AIR CONDITIONING EQUIPMENT AND OWNER FURNISHED EQUIPMENT. FURNISH AND INSTALL ALL ASSOCIATED RECEPTACLES AND DISCONNECT SWITCHES. FUSE SIZES FOR DISCONNECT SWITCHES SHALL BE AS RECOMMENDED BY THE EQUIPMENT MANUFACTURER. 3.02 TESTING A. ALL SYSTEMS AND EQUIPMENT INSTALLED SHALL BE COMPLETELY TESTED AND SHALL BE LEFT IN GOOD WORKING ORDER SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS PART 1 GENERAL 1.01 SUBMITTALS A. WIRING DEVICES PART 2 PRODUCTS 2.01 RACEWAYS A. RIGID STEEL CONDUIT B. ELECTRICAL METALLIC TUBING C. POLYVINYLCHLORIDE CONDUIT 2.02 WIRE AND CABLES A. FEEDERS AND BRANCH CIRCUIT WIRES: COPPER CONDUCTOR, 600 VOLT, TYPE THHN OR THWN INSULATION. 2.03 WIRING DEVICES A. WALL SWITCHES: AC GENERAL USE SNAP SWITCH WITH TOGGLE HANDLE, SPECIFICATION GRADE, 20 AMPERES, 120-277 VOLTS. B. RECEPTACLES: TYPE 5-15R, UNLESS INDICATED OTHERWISE, SPECIFICATIONS GRADE, IVORY PLASTIC FACE. C. COVERPLATES: NYLON, IVORY COLOR. 2.04 IDENTIFICATION A. PROVIDE LAMINATED PLASTIC TAGS FOR ALL PANELBOARDS AND DISCONNECT SWITCHES. TAGS SHALL COMPLETELY IDENTIFY EQUIPMENT MARKED OR CONTROLLED. SECTION 16500 LIGHTING PART 1 GENERAL 1.01 SUBMITTALS A. LIGHTING FIXTURES PART 2 PRODUCTS 2.01 GENERAL A. PROVIDE LIGHTING FIXTURE, AS SPECIFIED ON LIGHTING FIXTURE SCHEDULE OF SIZES, TYPES, RATINGS, AND WITH FEATURES INDICATED. SUBSITUTIONS SHALL BE EQUAL IN PERFORMANCE AND APPEARANCE TO FIXTURES LISTED. B. FIXTURES SHALL BE COMPLETE WITH LAMPS, BALLASTS, AND ALL PARTS, HARWARE, AND ACCESSORIES FOR INSTALLATION AND PROPER OPERATION. 2.02 LAMPS A. FLUORESCENT LAMPS: T8 TYPE BY GENERAL ELECTRIC OR PHILIPS. B. INCANDESCENT LAMPS: 120 VOLT, LONG -LIFE TYPE WITH A MINIMUM RATED LIFE OF 2,000 HOURS, BY GENERAL ELECTRIC OR PHILIPS. 2.03 FLUORESCENT BALLAST A. ELECTRIC TYPE, BY ADVANCE OR UNIVERSAL. PART 3 EXECUTION 3.01 GENERAL A. INSTALL FIXTURES AS INDICATED ON THE DRAWINGS. REFER TO REFLECTED CEILING PLAN FOR EXACT LOCATIONS. END OF ELECTRICAL SPECIFICATIONS. A 01\ 7-1 J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maitland, Florida 32751 t 407.740.8022 f: 407.740.8322 OFFICES IN Farmington Hllls, Michigan 248 324 8800 Dallas Texas 972 387 5900 11 NOTICE 11 THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GIVEN IN CONRDENCE . NO USE; IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF NUDELL ARCHRECTS. ALL RIGHTS ARE HEREBY SPECIFICALLY RESERVED. NUDELL ARCHITECTS COPYRIGHT YEAR 2011 RBE CONSUL TING SERVICES, LLC 2875 SPLIT OAK COURT - OVIEDO, FL 32766 MAIN PHONE LINE 407796.3820 FAX LIE 407-971-6718 WEBSITE. WWW RBECS. COM - EMAIL: RBECSLLC@GMAIL.COM STRUCTURAL DEPT: 407.796.3820 -EMAIL: RBEATTIE@RBECS.COM ELECTRICAL DEPT: 4OZ617.3113 - EMAIL: FAMILIBIA@RBECS.COM MECHANICAL DEPT: 407.796.3776 -EMAIL: NSHAW@RBECS.COM ROBERT M BEATTIE, PE; FLORIDA PE #55426 FLORIDA CERTIFICATE OF AUTHORIZATION #27269 iH OO MTM MMM LLC" MW EA WRY KMRU 1>s 00M11Nt LAW COPff0R MID 011101 PKMR Roos m RFS PLANS AND RE OM cWMED 1111ML 10 D® AND OIGINYS oIN1 Wr TO BE AL10M COPIED, ON RPRONICED N ANY ELRI Olt MAKER WAUT 11E OMEN MIM POMMBMIp1 ANO MNENT W -W C01MIum sum= LUC project title WEINGARTEN REALTY Interior Modification for B116 0TS11 In Marketplace at Seminole Towne Centre OCCUPANCY: Mercantile "M" Retail 1101 WP Ball Blvd & Towne Center Blvd F t title RICAL SYMBOL D AND MAIN R RISER NOT SCALE DRAWINGS �URED DIMENSIONS ONLY project number 2010-160 drawn FA checked WB approved RMB issued for date TENANT APPR 01-26-10 BIDDING 155UE 01-10-11 PERMIT ISSUE 01-10-11 BULLETIN NO 1 01-28-11 sheet EO SPECIFICATIONS - DMSION 16 - ELECTRICAL SECTION 16000 PART 3 EXECUTION BASIC ELECTRICAL REQUIREMENTS 3.01 RACEWAY PART 1 GENERAL A. ALL RACEWAYS SHALL BE INSTALLED IN ACCORDANCE WITH 1.01 REFERENCE STANDARDS MANUFACTURER'S INSTRUCTIONS. A. NFPA 70 NATIONAL ELECTRICAL CODE B. PERMITTED USAGE: B. NFPA 101 LIFE SAFETY CODE 1. ALL INTERIOR RACEWAYS SHALL BE GALVANIZED ELECTRICAL C. STANDARD BUILDING CODE METALLIC TUBING (EMT) EQUIPPED WITH STEEL SET SCREW D. ALL OTHER APPLICABLE STATE AND LOCAL CODES, COUPLINGS AND BOX CONNECTORS OR SHALL BE MC CABLING. 1.02 SUBMITTALS 2. RACEWAYS UNDERGROUND, EXPOSED TO EXTERIOR, OR CAST IN CONCRETE, SHALL BE GALVANIZED RIGID STEEL A. SHOP DRAWINGS CONDUIT (RGS) OR SCHEDULE 40 PVC. 1. SUBMIT FOR APPROVAL, PRIOR TO INSTALLATION, SIZ C. INSTALLATION COPIERS OF COMPLETE DESCRIPTIVE DATA ON ALL EQUIPMENT AND SYSTEMS AS REQUIRED BY OTHER SECTIONS OF THIS 1. IN LONG RACEWAYS FURNISH AND INSTALL THE PROPER SPECIFICATION. CLEARLY INDICATE ALL PROPOSED SUBSTITUTIONS NUMBER AND SIZE PULL BOXES TO FACILITATE INSTALLATION OF AND DEVIATIONS FROM DRAWINGS AND SPECIFICATIONS. CONDUCTORS. 2. CHECK ALL SUBMITTALS FOR CLEARANCES AND COORDITION 2. INSTALL SEPARATE GROUNDING CONDUCTOR IN EACH WITH OTHER TRADES. SUBMITTALS SHALL BE CERTIFIED, BY THE RACEWAY. CONTRACTOR'S APPROVED STAMP, THAT ALL CONDITIONS HAVE BEEN CHECKED AND THAT NO CONFLICTS EXIST. 3.02 WIRE AND CABLES B. RECORD DRAWINGS A. ALL POWER WIRING SHALL BE INSTALLED IN CONDUIT. MC CABLING SHALL BE PERMITTED FOR USE INSIDE STORAGE 1. SUBMIT, TO THE OWNER, RECORD DRAWINGS SHOWING BUILDINGS IN PLACE OF CONDUIT AND WIRE. TYPE NM FIELD CHANGES MARKED IN RED. CABLING SHALL BE PERMITTED IN APARTMENT / OFFICE BUILDING. 1.03 WORK INCLUDED SECTION 16400 A. THE WORK OF THIS SECTION INCLUDES FURNISHING OF SERVICE AND DISTRIBUTION LABOR AND MATERIALS ON REQUIRED FOR INSTALLATION OF NEW ELECTRICAL DISTRIBUTION SYSTEM INCLUDING SERVICE, PART 1 GENERAL PANELBOARD, BRANCH CIRCUITS, LIGHTING, CONNECTIONS TO ALL EQUIPMENT REQUIRING ELECTRICAL POWER AND MODIFICATIONS 1.01 SUBMITTALS TO AN EXISTING ELECTRICAL DISTRIBUTION SYSTEM AS REQUIRED DUE TO ARCHITECTURAL RENOVATIONS. A. PANELBOARDS 1.04 DRAWINGS B. DISCONNECT SWITCHES A. THE DRAWINGS ARE PARTLY DIAGRAMMATIC AND DO PART 2 PRODUCTS NOT SHOW IN DETAIL ALL REQUIRED FEATURES OF THE WORK NOR CONCEALED CONDITIONS. THEY SHALL BE 2.01 PANELBOARDS SUPPLEMENTED BY THE CONTRACTORS KNOWLEDGE AND EXPERIENCE. A. CIRCUIT BREAKER TYPE AS DESCRIBED ON THE PANEL SCHEDULES. APPROVED MANUFACTURERS ARE GENERAL ELECTRIC, SIEMENS AND SQUARE -D. PART 2 PRODUCTS 2.02 DISCONNECT SWITCHES 2.01 GENERAL A. FUSIBLE OR NONFUSIBLE QUICK -MAKE, QUICK -BREAK, LOAD A. ALL ELECTRICAL EQUIPMENT INSTALLED SHALL BEAR THE U.L. INTERRUPTER ENCLOSED KNIFE SWITCH WITH EXTERNALLY LABEL EXCEPT WHERE U.L. DOES NOT LABEL SUCH OPERABLE HANDLE INTERLOCKED TO PREVENT OPENING FRONT EQUIPMENT. COVER WITH SWITCH IN "ON" POSITION. APPROVED 2.02 GUARANTEE MANUFACTURERS ARE GENERAL ELECTRIC, SIEMENS AND SQUARE -D. A. FURNISH A WRITTEN GUARANTEE THAT ALL EQUIPMENT PART 3 EXECUTION FURNISHED AND INSTALLED WILL BE FREE OF DEFECTS OF MATERIAL AND WORKMANSHIP FOR A PERIOD OF 1 YEAR 3.01 GENERAL FROM DATE OF ACCEPTANCE OF THE WORK BY THE OWNER. PROMPTLY REPLACE AND REPAIR ALL DEFECTIVE EQUIPMENT A. MAINTAIN CODE REQUIRED WORKING CLEARANCES AROUND ALL AND ALL OTHER EQUIPMENT DAMAGED THEREBY AT NO ELECTRICAL EQUIPMENT. COORDINATE INSTALLATION WITH ADDITIONAL COST TO THE OWNER. ARCHITECTURAL FEATURES, PIPING LOCATIONS AND DUCTWORK. PART 3 EXECUTION 3.02 PANELBOARDS 3.01 GENERAL A. INSTALL NEW PANELBOARD AS INDICATED ON PLANS. A. VISIT PROJECT SITE BEFORE SUBMISSION OF BID AND B. ALL PANELS SHALL HAVE ENGRAVED PLASTIC LABELS AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND LOCATIONS TYPEWRITTEN DIRECTORIES. DIRECTORIES SHALL DESCRIBE TYPE OF OF EXISTING UTILITIES. LOAD AND LOCATION OF LOAD, USING OWNER'S SPACE NAMES B THE ENTIRE INSTALLATION SHALL BE MADE IN A NEAT OR NUMBERS, FOR EACH BRANCH CIRCUIT. MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE AND SHALL BE IN ACCORDANCE WITH THE REFERENCE STANDARDS listed above. C. MAKE POWER CONNECTIONS TO AIR CONDITIONING EQUIPMENT AND OWNER FURNISHED EQUIPMENT. FURNISH AND INSTALL ALL ASSOCIATED RECEPTACLES AND DISCONNECT SWITCHES. FUSE SIZES FOR DISCONNECT SWITCHES SHALL BE AS RECOMMENDED BY THE EQUIPMENT MANUFACTURER. 3.02 TESTING A. ALL SYSTEMS AND EQUIPMENT INSTALLED SHALL BE COMPLETELY TESTED AND SHALL BE LEFT IN GOOD WORKING ORDER SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS PART 1 GENERAL 1.01 SUBMITTALS A. WIRING DEVICES PART 2 PRODUCTS 2.01 RACEWAYS A. RIGID STEEL CONDUIT B. ELECTRICAL METALLIC TUBING C. POLYVINYLCHLORIDE CONDUIT 2.02 WIRE AND CABLES A. FEEDERS AND BRANCH CIRCUIT WIRES: COPPER CONDUCTOR, 600 VOLT, TYPE THHN OR THWN INSULATION. 2.03 WIRING DEVICES A. WALL SWITCHES: AC GENERAL USE SNAP SWITCH WITH TOGGLE HANDLE, SPECIFICATION GRADE, 20 AMPERES, 120-277 VOLTS. B. RECEPTACLES: TYPE 5-15R, UNLESS INDICATED OTHERWISE, SPECIFICATIONS GRADE, IVORY PLASTIC FACE. C. COVERPLATES: NYLON, IVORY COLOR. 2.04 IDENTIFICATION A. PROVIDE LAMINATED PLASTIC TAGS FOR ALL PANELBOARDS AND DISCONNECT SWITCHES. TAGS SHALL COMPLETELY IDENTIFY EQUIPMENT MARKED OR CONTROLLED. SECTION 16500 LIGHTING PART 1 GENERAL 1.01 SUBMITTALS A. LIGHTING FIXTURES PART 2 PRODUCTS 2.01 GENERAL A. PROVIDE LIGHTING FIXTURE, AS SPECIFIED ON LIGHTING FIXTURE SCHEDULE OF SIZES, TYPES, RATINGS, AND WITH FEATURES INDICATED. SUBSITUTIONS SHALL BE EQUAL IN PERFORMANCE AND APPEARANCE TO FIXTURES LISTED. B. FIXTURES SHALL BE COMPLETE WITH LAMPS, BALLASTS, AND ALL PARTS, HARWARE, AND ACCESSORIES FOR INSTALLATION AND PROPER OPERATION. 2.02 LAMPS A. FLUORESCENT LAMPS: T8 TYPE BY GENERAL ELECTRIC OR PHILIPS. B. INCANDESCENT LAMPS: 120 VOLT, LONG -LIFE TYPE WITH A MINIMUM RATED LIFE OF 2,000 HOURS, BY GENERAL ELECTRIC OR PHILIPS. 2.03 FLUORESCENT BALLAST A. ELECTRIC TYPE, BY ADVANCE OR UNIVERSAL. PART 3 EXECUTION 3.01 GENERAL A. INSTALL FIXTURES AS INDICATED ON THE DRAWINGS. REFER TO REFLECTED CEILING PLAN FOR EXACT LOCATIONS. END OF ELECTRICAL SPECIFICATIONS. A 01\ 7-1 J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maitland, Florida 32751 t 407.740.8022 f: 407.740.8322 OFFICES IN Farmington Hllls, Michigan 248 324 8800 Dallas Texas 972 387 5900 11 NOTICE 11 THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GIVEN IN CONRDENCE . NO USE; IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF NUDELL ARCHRECTS. ALL RIGHTS ARE HEREBY SPECIFICALLY RESERVED. NUDELL ARCHITECTS COPYRIGHT YEAR 2011 RBE CONSUL TING SERVICES, LLC 2875 SPLIT OAK COURT - OVIEDO, FL 32766 MAIN PHONE LINE 407796.3820 FAX LIE 407-971-6718 WEBSITE. WWW RBECS. COM - EMAIL: RBECSLLC@GMAIL.COM STRUCTURAL DEPT: 407.796.3820 -EMAIL: RBEATTIE@RBECS.COM ELECTRICAL DEPT: 4OZ617.3113 - EMAIL: FAMILIBIA@RBECS.COM MECHANICAL DEPT: 407.796.3776 -EMAIL: NSHAW@RBECS.COM ROBERT M BEATTIE, PE; FLORIDA PE #55426 FLORIDA CERTIFICATE OF AUTHORIZATION #27269 iH OO MTM MMM LLC" MW EA WRY KMRU 1>s 00M11Nt LAW COPff0R MID 011101 PKMR Roos m RFS PLANS AND RE OM cWMED 1111ML 10 D® AND OIGINYS oIN1 Wr TO BE AL10M COPIED, ON RPRONICED N ANY ELRI Olt MAKER WAUT 11E OMEN MIM POMMBMIp1 ANO MNENT W -W C01MIum sum= LUC project title WEINGARTEN REALTY Interior Modification for B116 0TS11 In Marketplace at Seminole Towne Centre OCCUPANCY: Mercantile "M" Retail 1101 WP Ball Blvd & Towne Center Blvd F t title RICAL SYMBOL D AND MAIN R RISER NOT SCALE DRAWINGS �URED DIMENSIONS ONLY project number 2010-160 drawn FA checked WB approved RMB issued for date TENANT APPR 01-26-10 BIDDING 155UE 01-10-11 PERMIT ISSUE 01-10-11 BULLETIN NO 1 01-28-11 sheet EO ELECTRICAL LEGEND COMMON GROUND CONVENIENCE DUPLEX RECEPTACLE TO BE NEMA 5-20R (HUBBLE MODEL #HBL5352) COMMON GROUND CONVENIENCE DOUBLE DUPLEX RECEPTACLE TO BE NEMA(2)-{5-20R (HUBBLE MODEL #HBL5352)} ISOLATED GROUND TWIST LOCK DUPLEX RECEPTACLE TO BE NEMA L5 -20R HUBBELL IG2310 MOTION ACTIVATED SWITCH LEVITON PART# ODS10-IDW (SEE NOTE #20 SHEET E-2) 0 J BOX FOR SIGN 0 TELECOM. ROUGH -IN ® CAT -5 ROUGH -IN © DOORBELL DISCONNECT SWITCH 3g. °N._....�- B ' CORD REEL (SEE NOTE #5 SHEET E-2) $ �t r � © ELECTRIC PANEL 'yJ EXISTING DUPLEX RECEPTACLE TO REMAIN. EXISTING DOUBLE DUPLEX RECEPTACLE TO REMAIN. LJJ EXISTING DISCONNECT SWITCH, TO REMAIN. B-2 LC- "� 'xi'LC-11 LC- x� �X� LC -9 LC- LC -8 __t£ x� �X, LC -7 LC- x4 JXJ' LC -8 PNL 'PP's I PNL "MTP" 0 d 0 PNL 'DB' I PNL 'A' PNL 'Be" 0 a 0 1 0 AD' B-6 B-6 I PP -14:16:18 I a II 1 x _. 4EX.7: A-42�: �u A-4 10 q IE -21 2 y ' QEF -3 A-40 A { PP -19:21 • -40 A-36 y I�` A-40 PP -13:15:17 fo p G nu 18r 1I �E-2 , .w A-31 IX. - ,- r ... ........... -.-.m- I A 18 4 E-2 y .. S I M13 -.-. E-2 IL»....»._. V44 18 A-19 w. E-2TFI._EPHONE A-35 _,q, r Igo, F A-3418.,_ A-21 1 A' .-. l 4 A-32 0 OFFIOF A- ° — _.. � OFFI A-30 E-2 r. _. A- sn L MANAGER � zo OFFICE CASH OFFICE-, A-28 RE -2 A- A -15 Z _ � ._E_2 2 o �"F_' p t11h:Tt I� A 1- A-28 A 28 A - 28 ? A-6 "ter A-281. PP -38:40:42 O IX. RTU -8 A-4 PP -25:27:29 ° . ° RTU -9 7-1 A-4 PP -8:10:12 c ,vi IX IIIA -4 € `U' A-4 A-37 PP -26:28:30 LJ 6 7..1 _...18 v @ H IX. 1-6 A-4 A- LEGEND NEW WALL EXISTING WALL # DETAIL/NOTE E-2 SHEET NUMBER S1 it ! 00 ° '0 1 CO 84" 20'' B-1 0 B-3 ; i T WIDESPAN VipV c B-5 ! PP -1:3:5 -01111-fill 0 0 lu B-25,27,29 $__.._._ I.G. 00 B-38,40,42 91 I.G. 47 B-32,34,36 B -26,28,J G. B-20,22,24 [I 8-10 B-12 A-39: N q4 E-2. 8 4 E-2 bF A-24 4 4q. E-2 -26 B-8 9'-1 B-31 B-14 0...._.._.._.w._,._.. E B-16 0 K A-3 c, pf °°, P•, M. a ®011 �,b° ��•��®pp0pppp•pw �� Ar Noespy . ra 23 a d'• : > M r �. '61n //drRt!!4r J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maitland, Florida 32751 t: 407.740.8022 f: 407.740.8322 OFFICES IN Farmington Hikk Michigan 248 324 8800 DaRm Texas 972 387 5900 NOTICE THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GNEN IN CONFIDENCE. NO USE, IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF NUDELL ARCHITECTS. ALL RKMTS ARE HEREBY SPECIFICALLY RESERVED. NUDELL ARCHITECTS COPYRr-1HT YEAR 2011 RBE CONSUL TING SER VICES, LLC 2875 SPLIT OAK COURT - OVIEDO, FL 32766 MAIN PHONE LINE: 402796.3820 - FAX LINE: 407-971-6718 WEBSITE WWW.RBECS.COM _ EMAIL.' RBECSLLC@GMAIL.CON STRUCTURAL DEPT: 40Z796.3B20 - EMAIL: RBEA TTIE@RBECS. COM ELECTRICAL DEPT.: 4 07. 617. 3113 - EMAIL: FAMILIBIA@RBECSCOM MECHANICAL DEPT.: 402796.3776 -EMAIL: NSHAH@RBECS.COM ROBERT M. BEATTIE, PE,• FLORIDA PE #55426 FLORIDA CERTIFICATE OF AUTHORIZATION #27269 9sE 0MV11EI SMCM LLC MW Ornmy RESEIM 118 CQEWN uM CW VMW AND 01110 FRWOM WAES 10 REQ RM AND 1 E OPTICA CMMO Nihil. REF DOW AND OEAIEEB NULL Wr m N: AL7M COPE$ N MPRDo1NtD N ANY POW! CE EANIER NEEIIR 7NE E7EEE88 NSi1FR PENE881011 AM CN ff W"IEE 110N&A.7EE0 tLC'. project title REALTYWEINGARTEN Interior Modification for In Marketplace at Seminole Towne Centre OCCUPANCY: Mercantile "M" Retail 1101 WP Ball Blvd & Towne Center Blvd F t title TRICAL OR PLAN NOT SCALE DRAWINGS GURED DIMENSIONS ONLY project number 2010-160 drawn FA checked RMB approved RM5 issued for date TENANT APPR 01-26-10 BIDDING 15SUE 01-10-11 PERMIT I55UE 01-10-11 BULLETIN NO 1 01-28-11 sheet E1 ELECTRICAL GENERAL NOTES GENERAL NOTES. 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITION BEFORE STARTING ANY WORK. ALL WORK SHALL BE 1) REFER TO SHEET E2 FOR GENERAL NOTES AND SPECIFICATION. COORDINATED WITH THE GENERAL CONTACTOR AND OTHER DISCIPLINES. ANY CONFLICTS SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT. 2) REFER TO SPECIFICATIONS. 2. THE ELECTRICAL CONTRACTOR SHALL VISIT THE EXISTING FACILITY AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND 3) ALL WIRING AND CONDUIT SHALL BE 2#12, 1#12G, IN 1/2'C, UNLESS OTHERWISE NOTED. SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT 4) ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FOLD VERIFYING ALL EXISTING CONDITIONS SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF AND DIMENSIONS PRIOR TO THE START OF CONSTRUCTION. DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. 3. INSPECT AND ALL POWER PANELS, BOXES BY CIONTRACTOR.CAL EQUIPMENT PLAN HEX NOTES, REUSED SHALL BECK: CLEANED,XISTING TESTEDRECEPTACLES, AND ADJUSTED THE ELECTRICAL ANY DEFECTIVE PARTS SHALLPROPOSED REPLACED TO BRING ELECTRICAL SYSTEM UP TO GOOD OPERATING CONDITION. 10 ROOF TOP UNIT. SEE EQUIPMENT FEEDER SCHEDULE FOR PROPER WIRE, CONDUIT AND 4. ALL UNUSED CONDUITS SHALL BE SAW CUT AND CAPPED BELOW FLOOR SLAB, ABOVE IN CEILING SPACE & BACK INTO WALL. DISCONNECT SIZES, PER LATEST NEC. SEE SHEET EO FOR DETAILS PATCH FLOOR AS REQUIRED TO MATCH EXISTING FLOOR FINISH. 20 BAILER: SEE EQUIPMENT FEEDER SCHEDULE FOR PROPER WIRE, CONDUIT AND 5. ALL UNUSED WIRE SHALL BE COILED UP AND CAPPED WITH WIRE NUT AND LEFT IN PLACE. DISCONNECT SIZES, PER LATEST NEC. SEE SHEET EO FOR DETAILS. 6. THE ELECTRICAL CONTRACTOR SHALL PREPARE A WRITTEN REPORT STATING: FIELD FINDINGS, OPERATING CONDITION OF ALL ELECTRICAL EQUIPMENTS, RECEPTACLES AND RECOMMENDATIONS. THIS REPORT SHALL BE SUBMITTED TO THE OWNER OR HIS REPRESENTATIVE. i 7. THE ELECTRICAL CONTRACTOR SHALLBE RESPONSIBLE FOR COORDINATING AND PROVIDING ANY FURTHER REQUIREMENTS NOT LISTED IN THIS DOCUMENT AS REQUE TED BY THE BUILDING INSPECTOR. i I A-10,12 i s PP -8:10:12 c ,vi IX IIIA -4 € `U' A-4 A-37 PP -26:28:30 LJ 6 7..1 _...18 v @ H IX. 1-6 A-4 A- LEGEND NEW WALL EXISTING WALL # DETAIL/NOTE E-2 SHEET NUMBER S1 it ! 00 ° '0 1 CO 84" 20'' B-1 0 B-3 ; i T WIDESPAN VipV c B-5 ! PP -1:3:5 -01111-fill 0 0 lu B-25,27,29 $__.._._ I.G. 00 B-38,40,42 91 I.G. 47 B-32,34,36 B -26,28,J G. B-20,22,24 [I 8-10 B-12 A-39: N q4 E-2. 8 4 E-2 bF A-24 4 4q. E-2 -26 B-8 9'-1 B-31 B-14 0...._.._.._.w._,._.. E B-16 0 K A-3 c, pf °°, P•, M. a ®011 �,b° ��•��®pp0pppp•pw �� Ar Noespy . ra 23 a d'• : > M r �. '61n //drRt!!4r J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maitland, Florida 32751 t: 407.740.8022 f: 407.740.8322 OFFICES IN Farmington Hikk Michigan 248 324 8800 DaRm Texas 972 387 5900 NOTICE THIS ARCHITECTURAL AND/OR ENGINEERING DRAWING IS GNEN IN CONFIDENCE. NO USE, IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF NUDELL ARCHITECTS. ALL RKMTS ARE HEREBY SPECIFICALLY RESERVED. NUDELL ARCHITECTS COPYRr-1HT YEAR 2011 RBE CONSUL TING SER VICES, LLC 2875 SPLIT OAK COURT - OVIEDO, FL 32766 MAIN PHONE LINE: 402796.3820 - FAX LINE: 407-971-6718 WEBSITE WWW.RBECS.COM _ EMAIL.' RBECSLLC@GMAIL.CON STRUCTURAL DEPT: 40Z796.3B20 - EMAIL: RBEA TTIE@RBECS. COM ELECTRICAL DEPT.: 4 07. 617. 3113 - EMAIL: FAMILIBIA@RBECSCOM MECHANICAL DEPT.: 402796.3776 -EMAIL: NSHAH@RBECS.COM ROBERT M. BEATTIE, PE,• FLORIDA PE #55426 FLORIDA CERTIFICATE OF AUTHORIZATION #27269 9sE 0MV11EI SMCM LLC MW Ornmy RESEIM 118 CQEWN uM CW VMW AND 01110 FRWOM WAES 10 REQ RM AND 1 E OPTICA CMMO Nihil. REF DOW AND OEAIEEB NULL Wr m N: AL7M COPE$ N MPRDo1NtD N ANY POW! CE EANIER NEEIIR 7NE E7EEE88 NSi1FR PENE881011 AM CN ff W"IEE 110N&A.7EE0 tLC'. project title REALTYWEINGARTEN Interior Modification for In Marketplace at Seminole Towne Centre OCCUPANCY: Mercantile "M" Retail 1101 WP Ball Blvd & Towne Center Blvd F t title TRICAL OR PLAN NOT SCALE DRAWINGS GURED DIMENSIONS ONLY project number 2010-160 drawn FA checked RMB approved RM5 issued for date TENANT APPR 01-26-10 BIDDING 15SUE 01-10-11 PERMIT I55UE 01-10-11 BULLETIN NO 1 01-28-11 sheet E1 BASIC WIRING REQUIREMENTS PLEASE REVIEW SPECIFICATIONS BELOW AND REFER TO SHEET E-1 FOR DESIGNATED LOCATIONS. NO ADDITIONS OR CHANGES TO THIS SCOPE OF WORK CAN BE MADE WITHOUT PRE -APPROVAL BY AUTHORIZED BIG LOTS REPRESENTATIVE. ALL WORK IS TO BE DONE IN A WORKMAN -LIKE MANNER, AND THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, AND COMPLIANCE TO ALL NATIONAL AND LOCAL CODES AND REQUIREMENTS. EXISTING CIRCUITS AND RECEPTACLES ARE TO BE UTILZED IN ALL CASES IF COST EFFECTIVE. PLEASE BREAK YOUR BID DOWN BY LINE ITEM WITH SPECIFICATIONS ON LABOR COSTS AND MATERIAL. ELECTRICIAN IS ALSO TO RETURN TO THE STORE 3-7 DAYS PRIOR TO DRY RUN OPENING TO VERIFY STORE LIGHTING IS FULLY FUNCTIONAL AND MAKE WHATEVER REPAIRS THAT MAY BE NEEDED. ANY QUESTIONS PLEASE CALL: 614-278-6719 or 614-278-6946. THANK YOU FOR YOUR ATTENTION IN THIS MATTER. TABLE OF CONTENTS 1. CASHWRAP CABINETS/FURNITURE CABINETS 2. EXTERIOR SIGNS 3. AUTOMATIC DOORS 4. CONVENIENCE RECEPTACLE 5. CORD REELS 6. COUNTDOWN ROOM 7. CASH ROOM 8. EMPLOYEE LOUNGE 9. MANAGER OFFICE 10. BALER 11. DOCK LIFT 12. RECEIVING LIGHT & DOORBELL 13. PHONE SYSTEM & ALARM BOARD 14. LAMP WALL PLUG MOLD 15. STORE LIGHTING 16. DOCK LIGHT 17. WATER COOLER 18. HAND DRYER 19. MOTION SENSOR 20. DOOR KIT VOLTS L -N : 277 MAIN OPTIONS REQUIRED PANEL : PP VOLTS PH.: 480 S.E. RATED : N/A MCB : AMPS PHASE : 3 GFI PROT.: N/A MLO : 400 AMPS MOUNTING : SURFACE SHUNT TRIP : N/A MFR : G.E. TYPE : AE EXISTING PANELBOARD 11 AIC RATING 22 KA ENCLOSURE DATA FULLY RATED OR SERIES RATED NEMA : 1 (MINIMUM, SEE SPECIFICATIONS) SECTIONS : 1 WIDTH/SECT.: 20 DEPTH : 6.00 DESCRIPTION LOAD CONN LOAD TYPE AMPS AMPS AMPS C.B. AMPS C.B. POLES CKT. NUM. CKT. NUM. C.B. POLES C.B. AMPS AMPS AMPS AMPS DESCRIPTION LOAD CONN LOAD TYPE RTU -1 64 20 64 1 1 80 3 1 2 3 80 64 2 RECEPTS RTU -2 64 20 CIRCUITS d' CIRCUITA 64 20 3 64 1 =-_ __= 3 4 =__ __= EF -2 64 5 =__= 64 20 1 64 20 1 20 1 64 =__ __= 5 6 =__ __= 21 0 64 =__= 64 20 RTU -3 40 20 40 ..., I rulsc.arT>,Sey RECEPTS 50 3 7 8 3 15 12 20 1 RTU -4 12 20 20 40 20 PLUGMOLD 40 5 =__ __= 9 10 =__ _-= 1 12 12 -__= 12 20 12 40 20 5 SPARE 40 ___ __= 11 12 =__ __= 14 1 12 =__= 12 20 RTU -5 16 20 16 2 2 35 3 13 14 3 20 13 0 CONTRACTOR TO PROVIDE A TELE/DATA ROUGH -IN, A 4" BOX @ 72" A.F.F. WITH 2-y4" RTU -7 13 20 RECEPTS 16 20 9) MANAGER OFFICE: 1 16 20 =__ __= 15 16 =__ __= 2 13 1 =__= 13 20 2 16 20 20 1 16 =__ __= 17 18 =__ __= 20 21 13 =__= 13 20 BAILER * 24 5 24 22 1 30 3 19 20 1 21 0 12 5 SPACE 0 22 1 24 5 1 24 1 =__ __= 21 22 1 12 5 0 0 ISPACE 0 22 26 24 5 20 1 24 =__ __= 23 24 1 1 0 1 30 0 SPACE 0 22 RTU -9 ** 32 20 32 4 2 40 3 25 26 3 20 13 29 30 RTU -6 13 20 9 32 20 2 32 12 =__ __= 27 28 =__ __= 32 13 20 5 =__= 13 20 3 32 20 12 5 32 =__ __= 29 30 =__ __= 20 12 13 =__= 13 20 SPACE 1 12 22 0 1 12 20 1 3 31 32 3 20 5 EF -3 12 JENERGY MAN 5 5 2 2 22 20 0 37 =__ __= 33 34 =__ __= 1 5 RECEPTS -__= 5 5 20 22 39 40 0 =__ __= 35 36 =__ __= SPARE 5 =__= 5 5 SPACE 41 22 0 20 6 3 37 38 3 30 24 SUBFEED C.B. OR FEED -THROUGH LUGS AS INDICATED, NOT APPLICABLE IF BLANK RTU -8 24 20 22 0 3 =__ __= 39 40 =__ __= 24 =__= 24 20 =__ 22 0 0 =__ __= 41 42 =__ __= 1 24 =__= 24 20 53 67 92 SUBFEED C.B. OR FEED -THROUGH LUGS AS INDICATED, NOT APPLICABLE IF BLANK ** PROVIDE LOCKING TYPE BREAKER ACTUAL CONN. LOAD : NEC DEMAND : AMPS 70 70 KVA 25 25 0 3 3 0 0 1 1 1 === === 0 0 =__ __= 0 307 307 307 : AMPS PHASE A : AMPS PHASE B : AMPS PHASE C * PROVIDE NEW BREAKER. ** PROVIDE NEW HACR BREAKER MATCH EXISTING ELECTRICAL EQUIPMENT. ACTUAL CONN. LOAD : NEC DEMAND : AMPS 307 307 KVA 255 255 VOLTS L -N : 120 MAIN OPTIONS REQUIRED PANEL : A VOLTS PH.: 208 S.E. RATED : N/A MCB : AMPS PHASE : 3 GFI PROT.: N/A MLO : 225 AMPS MOUNTING : SURFACE SHUNT TRIP : N/A MFR : G.E. TYPE : AG EXISTING PANELBOARD 11 AIC RATING 22 KA ENCLOSURE DATA FULLY RATED OR SERIES RATED NEMA : 1 (MINIMUM, SEE SPECIFICATIONS) SECTIONS : 1 WIDTH/SECT.: 20 DEPTH : 6.00 DESCRIPTION LOAD CONN LOAD TYPE AMPS AMPS AMPS C.B. AMPS C.B. POLES CKT. NUM. CKT. NUM. C.B. POLES C.B. AMPS AMPS AMPS AMPS DESCRIPTION LOAD CONN LOAD TYPE RECEPTS 2 2 3 - COMMERCIAL GRADE 20 1 1 2 1 20 6 HOLE 21 ROOF RECP 4 2 RECEPTS 1 2 2 CIRCUITS d' CIRCUITA 20 1 3 4 1 20 6 SPARE ROOF RECP 4 2 EF -2 12 5 5 12 20 1 5 6 1 20 1 9 RECEPTS 6 2 SPARE 1 21 0 1 20 1 7 8 1 20 8 21 ..., I rulsc.arT>,Sey RECEPTS 5 2 FACP ** 5 5 5 20 20 1 9 10 1 20 12 PLUGMOLD 12 5 SPARE 12 21 20 1 0 20 1 11 12 1 1 20 12 1 PLUGMOLD 12 5 SPARE 1 21 0 SPARE 20 1 13 14 1 1 20 0 6) COUNTDOWN ROOM: CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT. SPARE (HUBBELL HBL 5352, OR EQUIVALENT) 21 RECEPTS 1 2 2 (HUBBELL HBL 5232, OR EQUAL) 20 1 15 16 1 20 0 CONTRACTOR TO PROVIDE A TELE/DATA ROUGH -IN, A 4" BOX @ 72" A.F.F. WITH 2-y4" SPARE ROUGH -IN TO BE UTILIZED BY THE TELE/COM CONTRACTOR AT A LATER DATE. 21 RECEPTS 3 2 9) MANAGER OFFICE: 5 20 1 17 18 1 20 - IF 120/208v SERVICE IS AVAILABLE - PROVIDE ONE (1) 208/60 AMP CIRCUIT. CIRCUIT TO 2 RECEPTS 1 2 TELE RM ** 2 2 3 1 20 1 19 20 1 20 0 21 22 SPARE 20 21 TELE RM ** 2 2 3 21 20 1 21 22 1 20 0 1 SPARE 0 21 CAB 12 5 21 12 20 1 23 24 1 20 1 2 RECEPTS 1 2 CAB 12 5 12 0 20 1 25 26 1 20 2 20 1 RECEPTS 1 2 SPARE 21 21 1 0 1 30 2 27 28 1 20 6 SPARE IRECEPTS 4 2 SUBFEED C.B. OR FEED -THROUGH LUGS 21 0 === === 29 30 1 20 1 9 IRECEPTS 6 2 HAND DRY 12 5 12 0 20 1 31 32 1 20 5 RECEPTS 3 2 HAND DRY 12 5 12 20 1 33 34 1 20 12 HAND DRY 12 5 HAND DRY 1 12 5 1 1 12 20 1 35 36 1 20 1 12 EF -3 12 5 RECEPTS 1 1 2 2 20 1 37 38 1 20 2 RECEPTS 1 2 RECEPTS 1 2 2 20 1 39 40 1 20 6 RECEPTS 4 2 SPARE 21 0 20 1 41 42 1 20 6 RECEPTS 4 2 SUBFEED C.B. OR FEED -THROUGH LUGS AS INDICATED, NOT APPLICABLE IF BLANK 0 3 3 0 0 =__ __= 0 0 1 0 53 67 92 : AMPS PHASE A : AMPS PHASE B : AMPS PHASE C ** PROVIDE LOCKING TYPE BREAKER ACTUAL CONN. LOAD : NEC DEMAND : AMPS 70 70 KVA 25 25 1) CASHWRAP CABINETS / FURNITURE CABINETS CONTRACTOR TO PROVIDE ONE (1) 120v/20amp ISOLATED GROUND CIRCUIT (identified on diagram as I.G.) AND TWO (2) 120v/20amp CONVENIENCE CIRCUITS (identified on diagram as A & B), ALL CIRCUITS TO HAVE BREAKER LOCKS, FOR EACH CASHWRAP CABINET WITHIN THE STORE. CASHWRAP CABINETS EACH CABINET TO BE SUPPLIED ELECTRICAL CONDUCTORS VIA 2.25" X 2.25" TWIN CHANNEL TELE -POWER POLE FROM OVERHEAD TO THE CABINET. LENGTH OF TELE -POWER POLE TO BE DETERMINED BY THE CEILING/DECK HEIGHT. TELE -POWER POLE, WHITE IN COLOR, SUPPLIED BY CONTRACTOR. EACH CABINET IS TYPICALLY CONSTRUCTED WITH ELECTRICAL BOXES AND DEVICES SUPPLIED. WIRE CONDUCTORS AND CONDUIT ARE SUPPLIED BY CONTRACTOR. ALL WIRE CONDUCTORS AND CONDUIT ARE TO BE RUN HORIZONTALLY THROUGH THE CABINET AS TO NOT INTERFERE WITH ADJUSTABLE SHELF PLACEMENT. IN THE EVENT THAT THE CABINETS DO NOT CONTAIN ELECTRICAL BOXES, CONDUIT, AND DEVICES THE CONTRACTOR IS TO SUPPLY AND INSTALL THE FOLLOWING COMPONENTS PER THE DIAGRAM BELOW. EACH CABINET REQUIRES: - ONE (1) 4"x 4" JUNCTION BOX - FOUR (4) 2"x 4" ELECTRICAL BOXES - ONE (1) NEMA L5-2OR ORANGE TWISTLOCK RECEPTACLE (HUBBELL IG2310 2 POLE 3 WIRE GROUNDING 20A/125VAC) - THREE (3) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352 20A/125VAC) - ALL BOXES AND DEVICES TO HAVE APPROPRIATE COVER PLATES. ® 4 11 2 11" DIA. HOLE NEMA L5 20R SPECIAL PURPOSE DUPLEX 20A 125V RECEPTACLES UL/CSA BACK AND SIDE WIRED 0.5 HP DESCRIPTION CATALOG NUMBER ISOLATED GROUND, FLUSH, ORANGE RTP FACE IG2310 FRONT END CHECKOUT WIRING SCALE: NTS CONTRACTOR TO PROVIDE FOR EACH BUILDING SIGN LOCATION, 2 11" DIA. HOLE INSTALLED, FINAL ELECTRICAL CONNECTIONS TO BE COMPLETED BY ELECTRICIAN. (REGISTER/PC MUST ADEQUATE TO HANDLE SPECIFIED LOAD AND BE CONTROLLED BY EMS CABLES) 24" SQUARE HOLE 2 J" DIA. HOLE (POWER POLE) (CHECKOUT LIGHT) DOOR. 00 � CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT. CIRCUIT TO SUPPLY ONE O C) IINS EQUIVALENT) r- CONTRACTOR TO PROVIDE THREE (3) 120v/20amp CIRCUITS. CIRCUITS TO SUPPLY THREE (3) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES, FLUSH MOUNTED IN CEILING AT DESIGNATED LOCATIONS. CONTRACTOR TO INSTALL A CORD REEL AT N O CORD REEL DETAILS AND SPECIFICATIONS: r - COMMERCIAL GRADE IT 41 - UL RATED BOTTOM DECK 2" - GFCI RECEPTACLE DIA. SPARE HOLE 21 (VENDIHT ELEVATION 21 7' 0 s � Elac. Bax du NU~ LEFT SIDE CIRCUITS d' CIRCUITA 4 IG CIRCUIT 2z4 Eba Box RIGHT 4 SIDE Jaw Nk FURNITURE CABINET CONTRACTOR TO PROVIDE ONE (1) 120v/20amp ISOLATED GROUND CIRCUIT (identified on diagram as I.G.) AND ONE (1) 120v/20amp CONVENIENCE CIRCUIT (identified on diagram as A), ALL CIRCUITS TO HAVE BREAKER LOCKS, FOR THE FURNITURE CASHWRAP CABINET. CABINET TO BE SUPPLIED ELECTRICAL CONDUCTORS VIA 2.25" X 2.25" TWIN CHANNEL TELE -POWER POLE FROM OVERHEAD TO THE CABINET. LENGTH OF TELE -POWER POLE TO BE DETERMINED BY THE CEILING/DECK HEIGHT. TELE -POWER POLE SUPPLIED BY CONTRACTOR. EACH CABINET IS TYPICALLY CONSTRUCTED WITH ELECTRICAL BOXES AND DEVICES SUPPLIED. WIRE CONDUCTORS AND CONDUIT ARE SUPPLIED BY CONTRACTOR. IN THE EVENT THAT THE CABINET DOES NOT CONTAIN ELECTRICAL BOXES, CONDUIT, AND DEVICES THE CONTRACTOR IS TO SUPPLY AND INSTALL THE FOLLOWING COMPONENTS PER THE DIAGRAM BELOW. EACH CABINET REQUIRES: - ONE (1) 4"x 4" JUNCTION BOX - ONE (1) 4"x 4" ELECTRICAL BOX - ONE (1) 2"x 4" ELECTRICAL BOX - ONE (1) NEMA L5-2OR ORANGE TWISTLOCK RECEPTACLE (HUBBELL IG2310 2 POLE 3 WIRE GROUNDING 20A/125VAC) - TWO (2) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352 20A/125VAC) - ALL BOXES AND DEVICES TO HAVE APPROPRIATE COVER PLATES. POS/CASH REGISTER NOTES: *NOTE: UNDER NO CIRCUMSTANCES IS ANYTHING TO BE WIRED INTO THE IG RECEPTACLES. THESE ARE FOR THE DESIGNATED CASH REGISTER TWIST LOCK PLUGS ONLY! NOTE: THE GROUND WIRE IS TO TERMINATE AT THIS PANEL GROUNDING CONDUCTOR. IF SUB -PANEL IS USED FOR THESE CIRCUITS AND NO GROUND CONDUCTOR IS PRESENT, BOND TO PANEL ENCLOSURES AND CONTINUE GROUND TO CLOSET WATER PIPE OR BUILDING STEEL. A SEPARATE HOT, NEUTRAL AND LOW RESISTANCE PATH GROUND IS REQUIRED FOR THESE CIRCUITS. CONTRACTOR TO LABEL AND RECORD AMP DRAW, PER CIRCUIT, IN PANEL BOX CIRCUIT LABEL. *NOTE: DROPS TO EACH OF THE DESIGNATED CHECK-OUTS SHOULD BE RUN IN 2 CHANNEL TELE -POLES. I.G. CIRCUITS AND CONVENIENCE CIRCUITS ARE TO BE FED THROUGH THE SAME DROP. FURNITURE CHECKOUT WIRING SCALE: NTS 7' 4x4 EI-. Box CIRCUITA LEFT SIDE IG CIRCUIT 2z4 ❑ Eleo. Box RIGHT �B°x SIDE 21 II,, 2' C: Q 4x4 Ek., Bax LEFT ELEVATION 2 �' DIA. HOLE (REGISTER/PC CABLES) 41 zx4 EI ® El 4x4 J Box RIGHT ELEVATION 2) EXTERIOR SIGNS: CONTRACTOR TO PROVIDE FOR EACH BUILDING SIGN LOCATION, ONE (1) 120v/20amp CIRCUIT, CONTROLLED BY EMS EQUIPMENT. AFTER SIGN IS INSTALLED, FINAL ELECTRICAL CONNECTIONS TO BE COMPLETED BY ELECTRICIAN. CONTRACTOR TO PROVIDE POWER TO PYLON/STREET SIGN. POWER TO PYLON MUST ADEQUATE TO HANDLE SPECIFIED LOAD AND BE CONTROLLED BY EMS EQUIPMENT. 3) AUTOMATIC DOOR OPERATORS: CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT TO EACH ENTRY AND EXIT STOREFRONT DOOR LOCATION, TYPICALLY FOUR (4) LOCATIONS. CIRCUITS TO TERMINATE TO A 2x4 BOX w/COVER PLATE AT THE HEADER LOCATION OF EACH DOOR. 4) CONVENIENCE RECEPTACLE: CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT. CIRCUIT TO SUPPLY ONE (1) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLE (HUBBELL HBL 5352, OR EQUIVALENT) 5) CORD REELS: CONTRACTOR TO PROVIDE THREE (3) 120v/20amp CIRCUITS. CIRCUITS TO SUPPLY THREE (3) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES, FLUSH MOUNTED IN CEILING AT DESIGNATED LOCATIONS. CONTRACTOR TO INSTALL A CORD REEL AT EACH LOCATION PER THE DIAGRAM BELOW. CORD REEL DETAILS AND SPECIFICATIONS: ALEMITE CORD REEL MODEL 7260 OR EQUIVALENT TO BE: - COMMERCIAL GRADE - 20 AMP - UL RATED - 45' CORD - GFCI RECEPTACLE 0 SPARE 21 SPARE 21 0 du NU~ 1 3 4 1 20 F� SPARE 21 SPARE 21 p 0 20 1 5 y "a-, &E tit xys+r 1 20 0 SPARE 21 SPARE 21 0 CONN } 1 I ru n 1 7 8 1 20 0 SPARE 21 SPARE 21 ..., I rulsc.arT>,Sey 0 20 1 9 10 1 20 0 SPARE 21 SPARE 21 0 � r � �r 'w.-BMM#IIMUIplll�t le BBt ;,x 1 11 12 1 20 oub artlu " GwBwdoom n" nest SPARE 21 SPARE 21 0 20 1 13 14 1 20 0 SPARE M'LBRE SPARE 21 0 6) COUNTDOWN ROOM: CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT. CIRCUIT TO SUPPLY TWO (2) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352, OR EQUIVALENT) RECEPTACLES TO BE MOUNTED @ 46" A.F.F. DIRECTLY ABOVE THE COUNTERTOP MOUNTED AT 40" A.F.F. 7) CASH ROOM: CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT. CIRCUIT TO SUPPLY TWO (2) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5232, OR EQUAL) RECEPTACLES TO BE MOUNTED @ 36" A.F.F. DIRECTLY ABOVE THE COUNTERTOP MOUNTED AT 30' A.F.F. CONTRACTOR TO PROVIDE ONE (1) 120v/20amp ISOLATED GROUND CIRCUIT. CIRCUIT TO SUPPLY ONE (1) NEMA 5-20R ORANGE ISOLATED GROUND DUPLEX RECEPTACLES (HUBBELL CR53521G) RECEPTACLES TO BE MOUNTED @ 36" A.F.F. DIRECTLY ABOVE THE COUNTERTOP MOUNTED AT 30' A.F.F. CONTRACTOR TO PROVIDE A TELE/DATA ROUGH -IN, A 4" BOX @ 72" A.F.F. WITH 2-y4" EMT STUBBED ABOVE THE HARD CEILING, PULL STRING TO BE INCLUDED. THIS ROUGH -IN TO BE UTILIZED BY THE TELE/COM CONTRACTOR AT A LATER DATE. 8) EMPLOYEE LOUNGE: CONTRACTOR TO PROVIDE THREE (3) 120v/20 amp CIRCUITS. CIRCUITS TO SUPPLY THREE (3) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352, OR EQUIVALENT). 9) MANAGER OFFICE: CONTRACTOR TO PROVIDE TWO (2) 120v/20 AMP CIRCUITS. CIRCUITS TO SUPPLY FOUR (4) NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352, OR EQUIVALENT) 10) BALER. CONTRACTOR TO PROVIDE - - IF 277/480v SERVICE IS AVAILABLE - PROVIDE ONE (1) 480v/30 AMP CIRCUIT. CIRCUIT TO SUPPLY ONE (1) 30 AMP FUSED DISCONNECT - IF 120/208v SERVICE IS AVAILABLE - PROVIDE ONE (1) 208/60 AMP CIRCUIT. CIRCUIT TO SUPPLY ONE (1) 60 AMP FUSED DISCONNECT 11) DOCK LIFT (if applicable): CONTRACTOR TO PROVIDE ONE (1) THREE PHASE DISCONNECT TO BE INSTALLED MINIMUM (18) EIGHTEEN INCHES A.F.F., NEAR RECEIVING DOOR, AS DIRECTED. THE MOTOR IS MULTI TAP, ABLE TO OPERATE AT 208/230/3/60 OR 460/3/60, FROM THE SOURCE CIRCUIT. IF A SOUTH WORTH LIFT IS PROVIDED THE MOTOR SIZE IS 3.2 HP, AND IF AN ADVANCE LIFT IS PROVIDED THE MOTOR SIZE IS 5 HP, WIRE AND FUSE ACCORDINGLY. 12) DOOR BELLS: CONTRACTOR TO PROVIDE TWO (2) 24v, COMMERCIAL GRADE DOORBELLS. ONE (1) AT THE RECEIVING DOOR AND ONE (1) AT THE STOREFRONT DOORS. 13) PHONE SYSTEM & ALARM: CONTRACTOR TO PROVIDE TWO (2) 120v/20amp CIRCUITS. CIRCUITS TO SUPPLY TWO (2) NEMA 5-20R DUPLEX RECEPTACLES (HUBBELL HBL 5352 OR EQUIVALENT) WITHIN A 4" BOX (DOUBLE DUPLEX) ALL CIRCUITS TO HAVE BREAKER LOCKS. 14) LAMP WALL PLUG MOLD: CONTRACTOR TO PROVIDE TWO (2) 120V/20 AMP CIRCUITS. CIRCUITS TO SUPPLY 16' OF PLUG MOLD WITH RECEPTACLES @ 6" ON CENTER, ATTACHED TO THE WALLCASE GONDOLA @ 48" A.F.F., SWITCH REQUIRED AT PLUG MOLD LOCATION. 15) STORE LIGHTING: CONTRACTOR TO LABEL BREAKERS WITH DESCRIPTION AND AMP DRAW PER CIRCUIT. WIRING INSTRUCTIONS ARE AS FOLLOWS: CONTRACTOR TO WIRE EVERY OTHER FIXTURE AND EVERY OTHER ROW ON A SEPARATE CIRCUIT BREAKER ON SALES FLOOR AND STOCK ROOM. CIRCUIT BREAKERS ARE TO BE GROUPED BY CONTACTOR THE FOLLOWING WAY: EMPLOYEE CONTACTOR (CONTROLS ALL OFFICE, CASH, COUNT, BATHROOMS, RECEIVING AREA, AND STOCK ROOM. GROUP A 25% CONTACTOR (CONTROLS APPROXIMATELY THE NEXT 25% OF SALES FLOOR LIGHTS); GROUP B 50% CONTACTOR, (CONTROLS THE NEXT 25% OF SALES FLOOR LIGHTING); GROUP C 75% CONTACTOR, (CONTROLS THE NEXT 25% OF SALES FLOOR LIGHTING; GROUP D 100% CONTACTOR (CONTROLS THE BALANCE 25% OF SALES FLOOR LIGHTING); GROUP E CONTACTOR EXTERIOR SIGNS (CONTROLS ALL EXTERIOR BUILDING SIGNS INCLUDING PYLON SIGN). GROUP F CONTACTOR (CONTROLS ANY WALL PACK LIGHTING, PARKING LOT LIGHTING AND CANOPY LIGHTING NOT CONTROLLED BY LANDLORD). 16) DOCK LIGHT (if applicable): CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT. CIRCUIT TO SUPPLY NEMA 5-20R GENERAL DUTY DUPLEX RECEPTACLE (HUBBELL HBL 5352, OR EQUIVALENT). SWITCH REQUIRED AT RECEPTACLE LOCATION. MOUNT RECEPTACLE/SWITCH @ 48" A.F.F. BETWEEN DOORS OR WITHIN 12" OF DOOR FRAME. 17) WATER COOLER: CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT. CIRCUIT TO SUPPLY A ELKAY MODEL EZSTL8LC HI -LO WATER COOLER MOUNTED PER ALL LOCAL, STATE, FEDERAL AND ADA CODES OR REGULATIONS. 18) HAND DRYER: CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT (per unit). CIRCUIT TO SUPPLY A EXCEL MODEL XL -W ELECTRIC HAND DRYER, MOUNTED PER ALL LOCAL, STATE, FEDERAL AND ADA CODES OR REGULATIONS. 19) MOTION SENSOR SWITCHES: INSTALL SIX (6) - (BRAND AND MODEL) SWITCHES AT LOCATIONS (MGR OFFICE, COUNT OFFICE, CASH OFFICE, LOUNGE, AND RESTROOMS) AS INDICATED ON SHEET E-1. 20) DOOR KIT DISPLAY: CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT. CIRCUIT TO SUPPLY ONE (1) 4x4 BOX w/TWO (2) SWITCHES. - SWITCH (A) TO SUPPLY TWO (2) 8' PLUGMOLD w/RECPTACLES @ 6" ON CENTER. - PLUGMOLD (A) TO BE LOCATED ACROSS TOP -CENTER OF GONDOLA FIXTURE. - PLUGMOLD (B) TO BE LOCATED INSIDE DOOR KIT DISPLAY, ATTACHED TO GONDOLA FIXTURE PEGBOARD @ 64" A.F.F. - SWITCH (B) TO SUPPLY TWO (2) UNDERSHELF LIGHT FIXTURES (ANTARES GT534LC-41 K) MOUNTED TO UNDERSIDE OF THE TOP SHELF INSIDE THE DOOR KIT DISPLAY. VOLTS L -N : 120 MAIN OPTIONS REQUIRED PANEL : TL VOLTS PH.: 208 S.E. RATED : N/A MCB : AMPS PHASE : 3 GFI PROT.: N/A MLO : 225 AMPS MOUNTING : SURFACE SHUNT TRIP : N/A MFR : G.E. TYPE : AO EXISTING PANELBOARD AIC RATING 22 KA ENCLOSURE DATA FULLY RATED OR SERIES RATED NEMA : 1 (MINIMUM, SEE SPECIFICATIONS) SECTIONS : 1 WIDTH/SECT.: 20 DEPTH : 6.00 DESCRIPTION LOAD CONN LOAD TYPE AMPS AMPS AMPS C.B. AMPS C.B. POLES CKT. NUM. CKT. NUM. C.B. POLES C.B. AMPS AMPS AMPS AMPS DESCRIPTION LOAD CONN LOAD TYPE SPARE 21 0 20 1 1 2 1 20 0 SPARE 21 SPARE 21 0 20 1 3 4 1 20 0 SPARE 21 SPARE 21 0 20 1 5 6 1 20 0 SPARE 21 SPARE 21 0 20 1 7 8 1 20 0 SPARE 21 SPARE 21 0 20 1 9 10 1 20 0 SPARE 21 SPARE 21 0 20 1 11 12 1 20 0 SPARE 21 SPARE 21 0 20 1 13 14 1 20 0 SPARE 21 SPARE 21 0 20 1 15 16 1 20 0 SPARE 21 SPARE 21 0 20 1 17 18 1 1 20 0 SPARE 21 SPARE 21 0 20 1 19 20 1 20 0 SPARE 21 SPARE 21 0 20 1 21 22 1 20 12 EF -1 12 5 SPARE 21 0 20 1 23 24 1 20 0 SPARE 21 SPARE 21 0 20 1 25 26, 1 20 0 SPARE 21 SPARE 21 0 20 1 27 28 1 20 0 SPARE 21 SPARE 21 0 20 1 1 29 30 1 20 1 1 0 SPARE 21 SUBFEED C.B. OR FEED -THROUGH LUGS AS INDICATED, NOT APPLICABLE IF BLANK 0 3 3 0 0 =__ _-= 0 0 =__ __= 0 0 : AMPS PHASE A 12 : AMPS PHASE B 0 : AMPS PHASE C ACTUAL CONN. LOAD : NEC DEMAND : AMPS 4 4 KVA 1 1 J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maitland, Florida 32751 t: 407.740.8022 f: 407.740.8322 OFFICES IN Farmington Hills, Midigm 248 324 8800 Dallas Texas 972 387 5900 11 NOTICE 11 THIS ARCHrrECTURAL AND/OR ENGINEEPoNG DRAWING IS GIVEN IN CONFIDENCE, NO USE, IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF NUDELL ARCHITECTS. ALL RIGHTS ARE HEREBY SPECIFICALLY RESERVED. NLDELL ARCHITECTS COPY OGHT YEAR 2011 R -BE CONSULTING SERVICES, LLC 2875 SPLIT OAK COURT - OVIEDO, FL 32766 MAIN PHONE LINE: 407.796.3820 - FAX LINE.: 407-971-6718 WEBSITE.• WWW.RBECS.CON - EMAIL: RBECSLLC@GMAIL.COM STRUCTURAL DEPT: 407.796.3820 -EMAIL: RBEATTIE@RBEC$.COM ELECTRICAL DEPT: 407.617.3/13 -EMAIL: FAMILIBIAWRECS:COM MECHANICAL DEPT: 407.796.3776 -EMAIL: NSHAH@RBECS.COM ROBERT M. BEATTIE, FE; FLORIDA PE #55426 FLORIDA CERTIFICATE OF AUTHORIZATION #27269 'RBE CCN LAW O S AIT LLC' M P11 EI ff 1110 AP9mVE8 IIS oaAlan uw ooPrwort AID onEA mama walls m n®E PINTS AND 11E WO OWMI b VOK IM OEM AM mum BRALL NOT m BE AL100. COPED, M NOMM 11iD N MY IM OR WW RWRIW 11E EINRESS MIITU PERASSgn AM OMMII W;>ff COA@A.71101 IBM= LLC'. project title WEINGARTEN REALTY Interior Modification for B 14rr, LOTSF In Marketplace at Seminole Towne Centre OCCUPANCY: Mercantile "M" Retail 1101 WP Ball Blvd & Towne Center Blvd sheet title ELECTRICAL NOTES DETAILS AND SCHEDULES DO NOT SCALE DRAWINGS USE FIGMED DIMENSIONS ONLY project number 2010-160 drawn FA checked 1M6 al2proved RMB issued for date TENANT AFFIR 01-26-10 BIDDING 155UE 01-10-11 PERMIT ISSUE 01-10-11 BULLETIN NO 1 01-26-I1 sheet E2 _.... ......,,Yh.:...w.........._,:._.....L..,... ... - LIGHTING NOTES LIGHTING GENERAL NOTES 1. ALL LIGHT FIXTURES IN THE STOCK OR STORAGE AREA TO BE HUNG AT 14AFF. CONTACTOR SCHEDULE CONTACTOR SCHEDULE CONTACTOR SCHEDULE CONTACTOR SCHEDULE 1 - THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITION BEFORE STARTING ANY WORK. ALL WORK SHALL BE C— 7 SALES D C— 8 SALES D C— 9 OVERNIGHT C-11 COORDINATED WITH THE GENERAL CONTACTOR AND OTHER DISCIPLINES. ANY CONFLICTS SHALL BE REPORTED IMMEDIATELY TO THE 2. WHEN APPLICABLE ALL LIGHT FIXTURES IN THE SALES FLOOR TO BE HUNG FROM SALES C ARCHITECT. THE BOTTOM OF THE CEILING GRID BY THE CLIPS PROVIDED. ID ID ID ID 2. THE ELECTRICAL CONTRACTOR SHALL VISIT THE EXISTING FACILITY AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND 3. ALL PERIMETER LIGHTING FIXTURES ON THE SALES FLOOR TO BE MOUNTED NOTES NOTES NOTES NOTES SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND J. HOWARD BETWEEN 4' TO 6' FROM ANY WALL AND 10' ON CENTER WHERE APPLICABLE, ROWS POLE AMP PANEL CIRCUIT POLE AMP PANEL CIRCUIT POLE AMP PANEL CIRCUIT POLE AMP PANEL CIRCUIT DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT NUDELL SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF SHOULD RUN LEFT TO RIGHT FROM STORE FRONT. 1 30 L 26 1 30 L 4 1 30 L 28 1 30 L 38 DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. ARCHITECT 4. ALL THE LIGHT FIXTURES IN THE STOCK OR STORAGE AREAS TO BE MOUNTED AT 3. INSPECT AND CHECK: ALL EXISTING LIGHT FIXTURES PROPOSED TO BE REUSED SHALL BE CLEANED, RE-LAMPED TESTED AND ADJUSTED BY THE ELECTRICAL CONTRACTOR. ANY DEFECTIVE PARTS SHALL BE REPLACED TO BRING LIGHTING SYSTEM UP TO GOOD 12'-0" ON CENTER 500 Wlnderley Place ` 5. ALL TRACK LIGHTING TO BE INSTALLED AT 6" BELOW STRIP LIGHTING 2 30 2 30 L 8 2 30 L 32 2 30 L � OPERATING CONDITION. Sults 220 Maitland, Florida 32751 6. ALL LIGHT FIXTURES TO BE (COOPER) #SS-232-SYUQTP2X32UNIV-EB81 (4') AND 3 30 3 30 L 16 3 30 3 30 L 42 4. ALL UNUSED WIRE SHALL BE COILED UP AND CAPPED WITH WIRE NUT AND LEFT IN PLACE. t: 407.740.8022 f: 407,740,8322 #8TSS-232-SYUQTP4X32UNIV-EB81 (8') AND SHALL HAVE 4' T-8 SYLVANIA LAMPS, PART# 4 30 4 30 4 30 4 30 5. THE ELECTRICAL CONTRACTOR SHALL PREPARE A WRITTEN REPORT STATING: FIELD FINDINGS, OPERATING CONDITION OF ALL OFFICES IN F030/841/XP/SS/ECO AND SYLVANIA ELECTRONIC BALLAST PART# QTP2X32T8UNIV (4') AND EXISTING LIGHT FIXTURES AND RECOMMENDATIONS. THIS REPORT SHALL BE SUBMITTED TO THE OWNER OR HIS REPRESENTATIVE. Farmington Hills, MMfilpeut QTP4X32T8UNIV (8'). 6. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND PROVIDING ANY FURTHER REQUIREMENTS NOT 248 324 8800 7. ALL EMERGENCY FIXTURES TO BE (COOPER) #8TSS-232-120-EL-FBP24OH-SYUQTP4X32UNIV-EB81. LISTED IN THIS DOCUMENT AS REQUESTED BY THE BUILDING INSPECTOR. Dallas Texas 8. THE EXIT/EMERGENCY COMBO WILL BE A TECHNICAL CONSUMER PRODUCTS PART# TCP 20784 AND A 972 387 5900 REMOTE HEAD TECHNICAL CONSUMER PRODUCTS PART# TCP 207R4 9. ALL CHANGES TO BE APPROVED BY A BIG LOTS, INC. REPRESENTATIVE. s I 10. ALL WORK TO BE DONE IN A WORKMAN LIKE MANOR, WITH A ONE YEAR WARRANTY f ` r. ON THE LABOR AND MATERIAL OF INSTALLATION. 11. ALL LOCATIONS TO BE FIELD VERIFIED. I l LIGHTING LEGEND REMOTE HEAD TECHNICAL CONSUMER PRODUCTS PART# TCP 207R4 THIS ARCHITECTURAL. AND/OR ENdNEERING L-36 L-34 L-36 L-34 L-36 L-34 L-36 I I L-19 DRAWING IS MEN IN CONFIDENCE. NO USE, IQ I L-34 L-36 L-34 L-36 L-34 L-36 L-34 L-36 L-34 L-36 L-34 I IN WHOLE OR PART, MAY BE MADE WITHOUT EMERGENCY/EXIT SIGN TECHNICAL CONSUMER PRODUCTS PART# TCP 20784 I$ I A PRIOR WRITTEN CONSENT OF NUDELL 901v E3 r2 € I ARCHITECTS, ALL RGgTS ARE HEREBY L-171 I I I I SPECIFICALLY RESERVED. NEW 2 LAMP 4FT STRIP, (COOPER) #SS-232—SYL/QTP2X32UNIV—EB81 s f¢ L—� _ — I NUDELL ARCHITECTS SYLVANIA LAMP PART# F03O/841/XP/SS/ECO.64 TOTAL WATTS L-2 L-4 L-8 L-6 L-10 L-12 L-14 L-16 L-18 L-20 L-24 L-22 L-28 L_Y8 y` �� � 20,E P I I L-17 NEW 4 LAMP 8FT STRIP, (COOPER) #8TSS-232-SYUQTP4X32UNIV-EB81 I I SYLVANIA LAMP PART# F03O/841/XP/SS/ECO. 128 TOTAL WATTS. I fl L-13 iLL ILLJ LU ILL LU s LL LL EMER NEW 4 LAMP 8FT STRIP, (COOPER) #8TSS-232-120-EL-FBP24OH-SYL/QTP4X32UNIV-EB81 L-19 i i .I L-40 L-2 L-6 L-40 L-12 L-10 L-42 L-14 € L-20 L-42 L-22 4 L-24 L-42 L-26 I SYLVANIA LAMP PART# F030/841/XP/SS/ECO. 128 TOTAL WATTS L�._, ° i '' RBE I I CONSUL TING SER VICES, LLC 9 tl a S % 2875 SPLIT OAK COURT - OVIEDO, FL 32766 LIGHTING TAKE OFF NOTE: ` i E L-15 I L24 MAIN PHONE LINE' 407.796.3820 - FAX LINE. 407-97/-67/8 I ; _ L-18 L-20 L-22 L-26 + L-19 WEBSITE:WWW.RBECS..CON - EMAIL: RBECSLLC@GMAIL.COM CONNECT EMERGENCY LIGHTING: L-2 L-4 L 8 L-6 L-10 I L-12 L-14 L-16 � L-28 Count Name FIXTURES TO LOCAL LIGHTING CIRCUIT _E` I` _._ w•_ — STLECTICALDPT.:407.796.382-EM41b:RBEIBIAORRBECSCOM laS i I I y ELECTRICAL DEPL: 40L6/Z3/l3 EMAIL: FAMILIBIA®RBECS.COM AHEAD OF SWITCHING. _ MECHANICAL DEPT: 407,796.3776 - EMAIL: NSHAH�RBECS.COM 5 TCP REMOTE HEAD ?? j�/�J I I ROBERT M. BEATTIE, PE,• FLORIDA PE #55426 L i R y I FLORIDA CERTIFICATE OF AUTHORIZATION #27269 TCP EMERGENCY EXIT SIGN COMBO L-29 L-13 _____ _. _.___._.__.. _ _ I .______.._ __..___..._._____._.__ _,_.. __.__ -_,,_ __._,_ I __. _„___ ... ____ __ ' 6 oa_au.'O smlc�s _va_r osa"r ��I rB I onrlai uw carnar No onfx Jnr pans m n+ta� E_ ; __ __._._w _.__ _ ...,..._ __ _ ...__ __ _ _ - _..._ .. _ -_ _ L 2 ,.,.,__ _ _ _ _ _ _ 1.2... - ,.__. Lip,__.__... ,W 16„m,.,_. _ . __ .._._ L-44._ _ _ _ }.._ - �8�._,. _ 2 .,._ ° -24- L �8 L _ y g rum ac K &M wnrl. a ..,.,.,_._._._..___... ...,...._.__.., .,_..._..... _._..�.._...._,___..,_...____-__- r I , ...�,_.._. L$ , ,._ MY WNEBIm�our1°�D�1�Ifl_II£IlBfld r. 8 2 LAMP 4' STRIP ,� ff,� u 21 8' STRI P(EM E RG E N CY RIGHT) I L-17 ' TRIP EMERGENCY LEFT g::I L-15 _ _ _ I _ I _ 22 8 S ( ) a � . �` � !"°�.. �' L-40 L 4 i L 8 L 40 L-10 L-12 L-42 L-16 L-18 L-42 L__. L-22 L-42 L-28 I� project title 337 4 LAMP 8 STRIP_I -� I T LT L-13 I � _ TELE ONE I L-4 L-2 I L-6 L-8 L-12 L-10 L-16 L-14 L-20 L-18 L-22 ; L-24 L-26 L-26 CONTACTOR SCHEDULE , I _ mmlI ° r L19 Interior Modification h I, _ I o M I I EMPLOYEE C-1 I I for I i ID ` I POLE AMP PANEL CIRCUIT NOTES yea ' _I I L—'S L-2 L-4 L-8 L-6 L-10 L-12 L-14 L-16 L-18 L-20 L-24 I L-22 L28 L-28 1 30 L _,...... ___._3 ° yy I � I 2 30 L 3 4 � I I I I L-26 � 3 30 L 5 I L-13 L-191.- r_ �.: I I t L `- -7 C L-4 L-2 L -s L-8 L-12 L-10 L-16 L-14 L-20 L-18 L-22 ” L-24 L-26 I ■ ' I n J OFFICE ¢ S� L-15 w I a Marketplace at Seminole CONTACTOR SCHEDULE �=µ ( L-40 L-4 s L-8 L-40 L-10 L-12 L-42 L-16 L-18 L-42 L-24 L-22 L42 L-17 Towne Centre _. MAIC E ' I SALES A C-2 - r - - I of "E ' I I L-28 ID i � � � � FIE 1 II OCCUPANCY: NOTES � � � I � POLE AMP PANEL CIRCUIT L-13 Mercantile "M” M �--- L-4 L-2 L-6 L-8 L-12 L-10 L-16 L-14 L-20 L-18 L-22 L-24 L-28 L-19 CC UNTER Retail 1 30 L 10 2 30 L 14 °' 1 g d L-29 1101 WP Ball Blvd & Towne Center Blvd 3 30 '" _.._..____ L-40 L-13 L-15 L-1 1 ® L-17 I �I L-8 L-6 L-10 L-12 L-14 L-16 L-18 L-20 L-24 L-22 30 L-29 L-26 4 30 � �� I � A � � L-17 sheet title L-28 � � I�o .. � �� I f��.;�-r-- . ..�..���.����:A��,��--����.�� I � LIGHTING CONTACTOR SCHEDULE I "`. L-27 � L-6 L-40 L-12 � L-10 L-42 L-14 � L-20 L-42 L-22 L-24 L-42 �_; FLOOR PLAN SALES A C-3 ,� I - , _- - L-29 L-19 c �Y _ I I L -2s Do NOT SCALE DRAWINcas ID NOTES, 'i _ L_-f17� L -2S _ L-38 _ _ _ -_ _ _.. - _. _ ___._ _�.._ _.... _ - ._.. __. _ ____, _ _ __ _ _ _. _ _ _.. _�-__ • ._. _ __ _ _ ..._ _ __ . __-_w. __ . _._._-...__.... _._.._ _ _. __._._ _._ _ __ . _ _ _ _._. L._l� �7_ __ _ USE FIGURED DIMENSIONS ONLY 29 AMP PANEL CIRCUIT POLE I L-8 L-6 L-10 L-12 L-14 L-16 L-18 L-20 L-24 L-22 L-28 1 -1 1 30 L 22 `L� 9 _ ....::...,_. m. _ -W;m w .a L-5 L7 L-5 L-38 I L-17 project number 2 30 L 34 -2 2010-160 3 30 - I L- ° - - - 4 30 s_._._ __ _.--.— .�.-3 -. -. L-1 L-7 L 5 L-7 L-5 L-6 L-8 L-12 L 10 L-16 L 14 L-20 L 18 L-22 L-24 L-26 �. _ s L- L-5 ' A L-28 CONTACTOR SCHEDULE .-�' I I I � � drawn FA Il._ _ - L-5 L-7 L-8 L-6 L-10 L-12 L-14 L-16 ? L-18 L-20 L-24 L-22 L-28 L-26 I SALES B C-4 L-3 L-1 L 3 L-5 L 7 "I I checked �B ID I � �_ � RMB NOTES POLE AMP PANEL CIRCUIT 1 30 L 6 -1 L-3 L-1 L-7 L-5 L-7 L-5 , L-6 L-40 L-12 L-10 L-42 L-14 L-20 L-42 L-22 I L-24 L-42 L-28 ` issued for date 2 30 L 18 c: L-19 TENANT APPR 01-26-10 SSU 01 -10 -II 3 30w BIDDING ISSUE IT ISSUE 01-10-11 4 30 _L -17i --5__w___ 7_____ 7 L-8 L-6 L-10 L-12 L-14 L-16 L-18 L-20 L-24 L-22 L-28 L-26 I L- L-3 L -t L-3 L gym" M� BULLETIN NO 1 01-28-11 I s CONTACTOR SCHEDULE I L-" SALES B C-5 L-1 L-3 L-1 L-7 L 5 L-7 L-5 L-6 L-8 L-12 L-10 L-16 L-14 ' L-20 L-18 L-22 L-24 L-26 L-28 ID I I 0 NOTES _.,�.I POLE AMP PANEL CIRCUIT l I 1 30 L 24 I I E L-8 L-40 L-10 L-12 L-42 L-16 � L-18 L-42 L-24 L-22 L-42 L-26 �L-19 2 30 L 30 I% L- L-1 L-3 L-38 L7 L-5 L-38 V � 5 L-29 m. 3 30 L 36 I 9 I I �� ���"�. S � a. � I 4 30 � � ,.� IUF.�7� ,�� ���I�:�P,.:��C� IFM..A� E� - � I M I L-6 L-8 L-12 L-10 L-16 L-14 L-20 L-18 L-22 I L-24 L-28 L-26 - L-3 L-1 L-7 5 L-7 L-5 CONTACTOR SCHEDULE I L ,- A A L-17 SALES C C— 6 L-8 L-32 L-30 L-32 L-30 L-32 L-30 L-32 L-30 L-32 L-30 L-3 L-30 L-32 L-30 ; ---- I ID NOTES POLE AMP PANEL CIRCUIT �~ M. 2 30 L 12 I ___ _.._.,. _....._ .., _....._.._.._ .•• 1 sheet I ap No. w 3 30 L 20e - I.- . 4 30•• •• RIO' � ��q� LIGHTING FLOOR PLAN �. ®.b®.••s®• • , ,� �3SCALE: 1/8" = 1'-0" °"�°���°�10NA LONQ��� •'rJ Big Lots New Store FA System Requirements FA System Information Contact Michael Poe (614) 278-6846, epoe@biglots.com Fire Alarm Systems: Big Lots requires that all Fire Alarms (FA) be installed per the Authority Having Jurisdiction for the area. If the AHJ does not require a FA for the space Big Lots will require that the flow and tamper switches from the sprinkler system serving the space be monitored. Big Lots (BL) uses ADT to monitor all FA's installed in new stores. Following the installation of the FA by the LL or GC, ADT will take over the monitoring. No third party monitoring will be needed. ADT needs to monitor any FA directly from two installed phone lines. Depending on the needs of the GC to pass C of 0 inspections the GC may install these lines and transfer them to BL following the inspections. If the FA has been installed by a third party the LL or GC should be prepared to supply ADT with all necessary programming information including zones, passwords, etc. The GC and FA installers should be prepared for direct contact by an ADT representative to facilitate scheduling for the reprogramming of the FA panel. LL or GC must provide Big Lots with answers to the following questions following the execution of the lease: • Does the GC intend to install a FA exclusive to our space or is it going to be integrated into a larger LL system? If the FA is exclusive to Big Lots please see notes below. • If the FA is part of a larger LL system please provide information regarding monitoring company and contact numbers to add Big Lots store associates to the call list. LL or GC must provide Big Lots with the following information after the FA installer has been selected: • Site drawings in CAD format of the proposed FA • Any plan review notes regarding FA installation as required by the AHJ. • Contact information for the installing FA company • FA installer specifications such as panel type, devices, etc. • Inspection forms, record of completion, and as-builts left at the panel location in a binder per NFPA standards. Big Lots also require that the installing FA company install a FA that can be monitored and repaired by ADT. BL requires use of one of the FACP's as listed below: • FireLite MS9050 • Firelite MS92000DLS • Firelite MS9600 • Honeywell Vista 128FB • EST 2 • EST 3 • Bosch 7412 • Bosch 9412 • Honeywell Vista 100 • Silent Knight 5208 • Silent Knight 5808 Prior to converting the FA panel to ADT monitoring the following conditions must be met. 1. FA permit must be on site and available for ADT to inspect. 2. FA as-builts must be on site. 3. FA installer must be on site during inspections. ADT to be notified two days before inspection. 4. ADT to be notified two weeks before date of requested conversion. All communications formats for monitoring are to be in Contact ID. Permitting and Inspections - Please communicate all ongoing FA permitting issues , timelines, installation deadlines, and completion dates with Michael Poe If the LL is interested in contacting ADT directly for FA installation quotes: Jeff Dye - BL ADT Account Manager- 440-846-6086 The GC will be responsible for contacting Celeste Doane (614-278-7041) to transfer phone lines following the installation of the FA. AFIRE ALARM SYMBOL LEGEND [E] AUDIBLE SIGNAL APPLIANCE REALTYWEINGARTEN COMBINATION AUDIBLE / VISUAL SIGNAL APPLIANCE R -0 S DUCT MOUNTED SMOKE DETECTOR. S = SUPPLY R = RETURN. FDF VISUAL SIGNAL APPLIANCE Towne Centre FIRE PROTECTION TAMPER SWITCH RTU -1® FAN SHUTDOWN RELAY. RTU -1 INDICATES 1101 WP Ball Blvd & Towne Center Blvd HVAC UNIT THAT RELAY CONTROLS. (1) AREA HEAT DETECTOR O LOCK BOX 10 MANUAL PULL STATION 02 PHOTOELECTRIC TYPE AREA SMOKE DETECTOR A FIRE PROTECTION FLOW SWITCH FIRE ALARM SYSTEMS PLAN E: 3/32" = 1'-0" NOTE: CONTRACTOR TO FIELD VERIFY EXISTING RTU'S TO CONFIRM IF DUCT DETECTOR ARE EXISTING. IF NOT PROVIDE WITH NEW AS INDICATED AND CONNECT COMPLETE PER RISER DIAGRAM. FIRE ALARM LAT84" V v " - VISUAL DEVICES ��— `� F Zai 1. AUDIBLE/VISUAL DEVICES TO FACE OF TOP SHELF OF WALL GONDOLAS AFF ON PERIMETER SALES OR PER NFPA 72 6-4.4.3.2. F.P. SUPERVISORY & FIRE ALARM �-- F FLOW VALVES I 75 8 EL, CO T DEVICE AUDIOVISUAL UNLESS OTHERWISE NOTED. DEVICES 3. COORDINATE THAT ALL SMOKE DETECTORS TO BE MINIMUM 3'-0" FROM HVAC GRILLES PRIOR TO ROUGH—IN (DRAWINGS SHOW GENERAL LOCATION ONLY). 4. MOUNT FIRE ALARM PULL STATION SO ACTUATING DEVICE IS AT MAXIMUM 48" A.F.F. 5• COORDINATE WITH OWNER PROVIDED DOOR ACCESS CONTROL SYSTEM TO ACTIVATE FAAP FACP SYSTEM IN A FAIL SAFE MANNER IN CASE OF FIRE ALARM. J SPD DACT 6. ALTHOUGH DEVICES ARE LAID OUT TO MEET NEPA 72, EACH VENDOR'S EQUIPMENT IS UNIQUE AND MAY REQUIRE ADDITIONAL SPEAKERS AND STROBES TO FULLY COMPLY WITH CODES. FAILURE TO ALLOW FOR THIS AT BID TIME WILL BE DEEMED AS A (2) PHONE FAILURE BY THE CONTRACTOR TO MEET THE SPIRIT OR INTENT OF THE CODES, PLANS 20A CKT LINES OR SPECIFICATIONS. NO ADDITIONAL COMPENSATION WILL BE PAID TO COMPLETE THE PROJECT. #6 CU. 120 VOLT 7. FIRE ALARM PLANS ARE CONCEPTUAL AND ARE INTENDED TO GIVE THE CONTRACTOR A GENERAL SCOPE OF THE FIRE ALARM SYSTEM. FIRE ALARM CONTRACTOR SHALL SUBMIT ENGINEERED FIRE ALARM SYSTEM SHOP DRAWINGS FOR PERMIT. BOND TO 8. FIRE ALARM SHALL BE INTERFACED WITH ELEVATOR CONTROLLER. ELEVATOR SHALL BE NEAREST PANEL RECALLED TO THE FIRST FLOOR IN CASE OF ALARM. GND BUS. 9. PROVIDE SIGNAL LEVEL SURGE SUPPRESSION ON LINES EXITING BUILDING SUCH AS BACKFLOW PREVENTER FLOW AND TAMPER SWITCHES AND HVAC DEVICES. FIRE A N.T.S. CONTROL RISER DIAGRAM qOy ®eeyeasoepe® �`''A ®® w e 55 2 ° ,p N®. L .sem S 1 s no es o ��,Q� S e�C eeee•e•+��� ,�� N P,l, r�;11811110 ° 1 l J. HOWARD NUDELL ARCHITECT 500 Winderley Place Suite 220 Maitland, Florida 32751 t: 407.740.8022 f: 407.740.8322 OFFICES IN Farmington Hik Michigan 248 3248800 Dallas Texas 972.387 59W 11 NOTICE 11 THIS ARCHRRECTURAL AND/OR ENGINEERING DRAWING IS GIVEN IN CONFIDENCE. NO USE IN WHOLE OR PART, MAY BE MADE WITHOUT PRIOR WRrFrEN CONSENT OF NUDELL ARCHTECTS, ALL ROM ARE HEREBY SPECIFICALLY RESERVED, NUDELL ARCHITECTS COPYRIGHT YEAR 2011 R—NE CONSULTING SERVICES, LLC 2875 SPLIT OAK COLT - OVIEDO, FL 32766 MAIN PHONE LINE., 401.796.J820 . FAX LINE 407-971-6718 WEBSITE: WWW.RBECS.COM ^ EMAIL: RPECSLLC@GMAIL.COM STRUCTURAL DEPT: 407796.3820 - EMAIL: RBEATTIE@RBECS.COM ELECTRICAL DEPT: 407617.J1I3 - EMAIL: FAMILIBIA@RBECS.COM MECHANICAL DEPT: 402196.3716 -EMAIL: NEHAH@RBECS.COM ROBERT M. BEATTIE, PE FLORIDA PE #55426 FLORIDA CERTIFICATE OF AUTHORIZATION #27269 'Rai 0=L1W S9tKM LLC' HOW EIFAMY F4911 FR r1S 0trerl LAE OLPYIIQIIT AM OM PIICPFRIY 1x81510 I ESE PINTS AND RE MW CWAMM MOr. 1118 01WI AND auras 98A11 NOT m BE ALUM CM OR 110TAR 1>D N ANY FM a< WMEM MMff 111E EMRESS WEN PEMI8910N AM 0MIO r OF IM OMML11a SMOCErk LLC. project title REALTYWEINGARTEN Interior Modification for In Marketplace at Seminole Towne Centre OCCUPANCY: Mercantile "M" Retail 1101 WP Ball Blvd & Towne Center Blvd sheet title FIRE ALARM SYSTEMS PLAN DO NOT SCALE DRAWINGS USE FIGURED DIMENSIONS ONLY project number 2010-160 drawn FA checked RM5 approved RM5 issued for date TENANT APPR 01-26-10 BIDDING 15SUE 01-10-11 PERMIT ISSUE 01-10-11 BULLETIN No 1 01-28-11 sheet FA1