Loading...
HomeMy WebLinkAbout695 Towne Center Blvd (a)i S Mbo fs Le enib X COLUMN BUBBLE CX DOOR NUMBER XX/A-X I I DETAIL BUBBLE I I LJ ROOM NAME ROOM NAME 4 NUMBER XX/A-X SECTION XX/A-X ELEVATION X PARTITION TYPE & DUPLEX RECEPTACLE EXI5TIN6 DOOR r NEW DOOR PAINT COLOR L> PAINT General Notes I. THESE DRANING5 INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURE, DE51G114 CONCEPT OF THE BUILDING AND ANY MAJOR ARCHITECTURAL ELEMENTS OR MAJOR TYPES OF MEP AND STRUCTURAL ELEMENTS. THE DRAWING5 DO NOT NEGE55ARILY INDICATE OR DESCRIBE ALL WORK FOR FULL PERFORMANCE AND COMPLETION OF THE 50OPE INDICATED, DESCRIBED OR IMPLIED. THE GENERAL CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE EXECUTION AND TIMELY COMPLETION OF THIS PROJECT. 2. PRIOR TO COMMENCEMENT OF WORK THE GENERAL CONTRACTOR SHALL CAREFULLY STUDY THE CONTRACT DOCUMENTS AND ALL EXISTING SITE CONDITIONS, THE 6ENERAL CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY INCONSISTENCY ERRORS, AND OR OMISSIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. FAILURE TO NOTIFY THE ARCHITECT OF DISCREPANCIES AND/OR UN5ATI5FAGTORY CONDITIONS WILL BE CONSTRUED AS AN ACCEPTANCE OF THE CONDITIONS TO PROPERLY PERFORM ALL REQUIRED WORK. 5. THESE DRAWINGS AND COPIES THEREOF ARE LEGAL INSTRUMENTS OF SERVICE FOR USE BY THE CLIENT AND MR. LARRY L. CHRISTIAN, A.I.A. ONLY. 4. ALL TRADES SHALL BE RESPONSIBLE FOR KNOWLEDGE of RELATIVE INFORMATION CONTAINED IN DOCUMENTS AND THE CONDITIONS UNDER WHICH THEY WILL BE EXPECTED TO PERFORM. 5. DIMENSIONS AND DETAILS SHALL BE VERIFIED PRIOR TO COMMENCEMENT OF CONSTRUCTION. TYPICAL DETAILS SHALL APPLY WHERE 5PECIFIG DETAILS (OR SECTIONS) ARE NOT GIVEN. 6. DEVIATIONS FROM THESE DOCUMENTS NECESSITATED BY FIELD CONDITIONS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION IMMEDIATELY. 7. ALL CONSTRUCTION SHALL CONFORM WITH THE CURRENT BUILDING CODES AND ALL LAWS AND ORDINANCES OF THE AGENGIE5 HAVING JURISDICTION. 8. DO NOT SCALE DRANIN65. BEFORE COMMENCING CONSTRUCTION CONTRACTOR SHALL VERIFY ALL DIMENSIONS, NOTIFY ARCHITECT IMMEDIATELY IF A CONFLICT ARISES WITH INTERPRETING THE PLANS, 9. MISCELLANEOUS BUILDING SIGNAGE 15 NOT PART OF THI5 PACKAGE (N.I.G). 10. UNLE55 OTHERWISE NOTED, STATED MANUFACTURER'S ITEMS SHALL BE "OR EQUAL11. CONTRACTOR SHALL RECEIVE APPROVAL FOR ALL SUBSTITUTIONS IN WRITING BY ARCHITECT PRIOR TO BID AND/OR INSTALLATION. II. THE REVIEW OF SHOP DRAWING5 BY THE ARCHITECT SHALL NOT RELIEVE IN ANY MANNER THE GENERAL CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS. 12, ALL PRIMARY ENTRANCES AND REQUIRED EXITS TO AND FROM THE BUILDING SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED. 13. FIRE PROTECTIONS FACILITIES, INGLUDING AGGE55 MUST BE PROVIDED PRIOR TO AND DURING CONSTRUCTION. 14. GENERAL CONTRACTOR TO SECURE PERMITS REQUIRED BY ALL JURISDICTIONS. 15. BUILDING APPRE55 NUMBERS SHALL BE EA51LY SEEN FROM THE STREET. I6. ALL REQUIRED EXIT SIGNS SHALL BE SELF -ILLUMINATING, RED AND WHITE IN COLOR AND WIRED TO BUILDING ELECTRICAL WITH BATTERY BACKUP. 17. ALL REQUIRED EXITS TO BE OPERABLE FROM THE IN51DE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLED6E OR EFFORT. NO DEAD BOLTS, NO 5LIDIN6 BOLTS 10. ALL DECORATIVE MATERIALS SHALL COMPLY WITH ALL ARTICLES OF THE BUILDING CODE, 19. 00115TRUGTION SHALL COMPLY KITH ALL ARTICLES OF THE BUILDING CODE. 20. CONSTRUCTION SHALL CONFORM WITH CURRENT ADA, TAS, AND LIFE SAFETY-NFPA 101 REQUIREMENT5. 21. PANIC HARDWARE TO BE INSTALLED AT REAR EXIT DOORS, 22. THE GENERAL CONTRACTOR SHALL GUARANTEE THAT ALL WORK INCLUDED IN THIS CONTRACT WILL DE FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF NOT LE55 THAN ONE (I) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THI5 PROJECT. THE CONTRACTOR FURTHER A6REE5 THAN ANY OR ALL DEFEGTS SHALL BE PROMPTLY REPAIRED AND/OR REPLACED AT CONTRACTOR'S OWN EXPENSE, AL50 ANY ITEM WHICH BECOMES DEFECTIVE DURING THE PERIOD OF THI5 GUARANTEE. 25. THE CHARACTER AND SCOPE OF WORK ARE ILLUSTRATED BY THESE WORKING DRANIN65. CONTRACTOR SHALL CAREFULLY EXAMINE ALL THE DRANINC75 AND SHALL BE RESPONSIBLE FOR THE PROPER INSTALLATION OF THE NORK. 24. IT 15 THE RESPON51BILITY OF THE CONTRACTOR TO ASCERTAIN THE FOLLOWING PREVAILING PROCEDURES KITH RE6ARD5 TO OPERATING. A. 5TORAGE FACILITIES B. PROTECTION OF EXI5TING NORK G. AGGE55 TO WORK AREA D. HOURS NORK 15 PERMITTED E. AVAILABILITY OF WATER, POWER, TELEPHONE, RESTRICTIONS, PROTECTION LIMITATIONS 25. IT SHALL BE THE RESPONSIBILITY OF EACH 5013 -CONTRACTOR TO CHECK THE RULES AND RE6ULATION5 GOVERNING WORK ON THE PREMISES. 26, CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS FROM GOVERNMENTAL AGENCIES INVOLVED PRIOR TO FINAL PAYMENT, 27. GENERAL CONTRACTOR TO VERIFY CONDITION OF EXISTING CONDITIONS. 28. IF COORDINATION D15GREPANGIE5 EXIST WITHIN THESE DOCUMENTS, THE MORE EXPENSIVE OF THOSE DISCREPANCIES WILL BE REQUIRED. 21q. BUILDING INSULATION SHALL HAVE A FLAME SPREAD RATING NOT GREATER THAN 25 AND A SMOKE DEVELOPMENT RATING NOT GREATER THAN 450. 50. 1" TELEPHONE CONDUIT KITH PULL -STRING FROM CABINET TO SPACE, STUBBED 6" ABOVE FINISH FLOOR. 51. (5.G. SHALL INSTALL I DUPLEX OUTLET ADJACENT TO THE TELEPHONE BOARD 52. O.C. TO REPAIR DAMAGED OR HORN SURFACES ON EXTERIOR AND INTERIOR OF BUILDING INCLUDING BUT NOT LIMITED TO: GRAFFITI, RUST HORN SURFACES, WATER STAINS, DAMAGED PAINT, ETC... 65. G. TO SUBMIT DOCUMENTATION 4 PHOTOGRAPHS OF QUE5TIONABLE ITEMS, NOT NOTED ON THE DRAWINGS, TO THE ARCHITECT 4 ONNER FOR EVALUATION, PRIOR TO COMMENCING WORK. O F FIC� ® S REVIEW UTY OF S'. MATTI ESS FIIPM PERMIT # O -9 Ar%f tv"t rr ,,, 4 A 9 -9 A if% /Omftl tN -d A4L e"% -4 A ■ ■ o ICode Data I Project Directo-q codes: 2004 FLORIDA BUILDING CODE 2004 FLORIDA FIRE -PREVENTION CODE 2004 FLORIDA PLUMBING CODE 2004 FLORIDA ELECTRIC CODE 2004 FLORIDA MECHANICAL CODE MI 2006 FLORIDA BUILDING CODE SUPPLEMENTS) FLORIDA ENERGY CODE Code Aua(pis I. DESCRIPTION OF WORK: NEW INTERIOR TENANT IMPROVEMENTS - USE 4 OCCUPANCY CLASSIFICATIONS: MERCANTILE GROUP I'M" - LEASEABLE FLOOR AREA: 115 OCCUPANTS A) SHOWROOM B) MEN/WOMEN/RECORD 4 FILES HALL G) VAULE CENTER TOTAL 2. CONSTRUCTION TYPE - # OF STORIES: ONE STORY - CONSTRUCTION TYPE: TYPE II B - BUILDING DOES NOT HAVE SPRINKLER SYSTEM 5, ALLOWABLE FLOOR AREA 5,444 50. FT. / 50 = 115 OGGUP. 61 1 50. FT. '70 50. FT. 4,221 50. FT. = 115 OCGUP. ALLOWABLE FLOOR AREA PER CODE: 12,500 e f LEASABLE SPACE: 4,221 sf < 12,500 5f (ALLOWABLE PER CODE) 4. EXITING - REQUIRED EXITS PER CODE: 115 OCCUPANTS < 500 OCCUPANTS = 2 EXITS - TRAVEL 015TANGE PER CODE: 200' WITHOUT SPRINKLER SYSTEM - 115 OCCUPANTS / 2 REQUIRED EXITS = 5a OCCUPANTS - 58 OCCUPANTS (0.2) = 11.611 OF REQUIRED EXIT WIDTH PER DOOR (31-011 OF DOOR WIDTH MIN) - MINIMUM CLEAR AISLE WIDTH 36" MIN. - MINIMUM CLEAR CORRIDOR WIDTH 44" MIN. - MINIMUM EXIT WIDTH PER LEAF 52" MIN. 3611 PROVIDED 5. PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH NFPA 10, STANDARDS FOR FIRE EXTINGUISHERS, FURNISH AND INSTALL AT LOGATION5 DIRECTED BY THE FIRE MARSHAL. - FIRE EXTINGUISHERS SHALL BE A MINIMUM 2A-IOB;G - TRAVEL DISTANCE TO A FIRE EXTIN6U15HER SHALL NOT EXGEED 75 FEET. - TOP OF FIRE EXTINGUISHER HAYING A GROSS WEIGHT LESS THAN 40 LBS, SHALL BE OT MORE THAN 48'1 ABOVE THE FLOOR OR 42" ABOVE FLOOR WITH A GROSS WEIGHT GREATER THAN 40 LBS. C T e Project: INTERIOR IMPROVEMENTS FOR: THE MATTRE55 FIRM, INC. PERMIT 5ET SEMINOLE TONNE CENTER 615 TONN CENTER BOULEVARD SANFORD, FLORIDA 527-11 Builbinq Department: CITY OF 5ANFORD, FLORIDA BUILDING DIVISION 500 N. PARK AVE. SANFORD, FLORIDA 52771 PHONE: 40-1-550-5600 Lanbforb: A.01 E6RE55 PLAN 4 EMERGENCY PLAN SUN COAST RETAIL, LLC, 5501 EDLOE 5T., SUITE 100 HOUSTON, TEXAS 77027 PHONE: 715-961-0280 FAX: 715-161-020101 ATTN: TODD NOMAGK Tenant: THE MATTRESS FIRM, INC. � 5815 GULF FREEWAY HOUSTON, TEXAS 77025 PHONE: 715-651-2049 FAX: -115-121-4058 ATTN: MR. GARY WHITE - VIGE PRESIDENT OF REAL ESTATE .Arc itect: LARRY L. CHRISTIAN, A.I.A. 3801 KIRBY DRIVE, SUITE (200 HOUSTON, TEXAS 77018 A2 FIXTURE PLAN, SCHEDULED FINISH PHONE: '113-664-70174 FAX: 713-664-9756 ATTN: MR. LARRY L. CHRISTIAN, A.I.A., N.G.A.R.B. MEP Engineer: JORDAN 4 SKALA EN6INEER5, INC. 14240 MIDWAY ROAD, SUITE 550 DALLA5, TEXAS 15244 A4 INTERIOR ELEVATIONS PHONE: 4601-585-1616 FAX: 461-385-1615 ATTN: MR ANDREW SMITH P E Project No.: 0805-776,14 Date. 07.2$.2003, Set No.: :i i V C ristian i • A916A9 A Texas Corporation 3801 Kirby Drive; Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 77 �titiJ l EXPIRES: 02.28:2009 f Christian, All . F t✓✓,r � K � n'. . * ?itect,ral Rep1StT ,I > b � 4)'! AR 0755-00 Drawing Index REVISIONS TO DATE Drawings DRAWING NO, PERMIT 5ET REVISED DRANIN65 COVER SHEET 07.28.2008 A.01 E6RE55 PLAN 4 EMERGENCY PLAN 07.28.2008 AO.5 UL DIRECTORY LISTING SHEET 01.28.2008 Al FLOOR PLAN 07.28.2008 A2 FIXTURE PLAN, SCHEDULED FINISH 07.28.2008 A3 REFLECTED GEILIN6 PLAN 07.28.2008 A4 INTERIOR ELEVATIONS 07.28.2008 A5 ENLAR6ED TOILET PLAN, ELEVATION, 07.28.2008 AGGE551B1LITY REQUIREMENTS, 516NA6E IDENTIFICATIONS A6 DETAILS AND PARTITION TYPES 07.28.2008 ADA -I ACGESSIBILITY STANDARDS 07.28.2008 M-1 MECHANICAL PLAN, LEGEND, DETAILS AND SCHEDULE 07.28.2008 E -I LIGHTING LEGEND, DETAILS SHEET 07,28.2008 E-2 LIGHTING PLAN 07,28.2008 E-5 POWER PLAN 07.28.2008 P-1 PLUMBING PLAN 07.28.2008 '' Contractor: TRINITY RETAIL GONSTRUGTION 2000 CYPRESS LANDING DRIVE HOUSTON, TEXAS 77010 PR\ OTECL LOCATION TEL: 715-4010-1200 MATTRESS 1:111 I I FAX: 715-410-1201 Seminole Towne Center ATTN: RODNEY STEPHENSON �n -� •v�rr r * S'V MATTRESS FIRM O REiAILOUILDING O y \ Seminole Towne Centex - f s i 695 Town Center Boulevard San f orb, Floriba 32-771 :t L �� ; t / ✓� Local Map y�� , N y r LT e. L '_ _ 111111111f11111111111111IIIµ LE Separate Life Safety drawings will be required for '� Ila VINW new systems or alterations to existing fire sprinkler systems, Plans must show sprinkler head locations, pipe sizing, and hydro calculations (if needed) and product cut sheets. Approval of the SITEMAP Plan set is required prior to request of inspection. i - NORTH ` ... ■ ■ 944-9000 'ON 130[oxd ■ ■ 800 W,40 :91eQ iso—V NV Id J.'DNA9NAH:1 � ■ ■ ■ 9940t00—iIV4 uoqu.118120g junlooliq v eppold V'I"V u-gsuw "I SiavI 60'9z'z0 .eaatdaa 9946 t99 EI4 :xeJ V464 Y99 C14 :104 96044 suxO L 'u04sn0H 009 o1juS `,aq Xq-q .X 1089 0 ■ ■ I� ■ ■ V'1'V'NV11SI2iH0 - &�Lv 'I g00z .LLI']1U,&d0:) 'CTiLLIHIHWd SI NOLLOIlQ02Id32I'SO IlIHO�IV HH.L dO NOLLVdIOLL21Vd QNV'IVAOX(ldV iIII1. ,IHOH,LIM SNOI.LVOO`i uiIII.LO NI 2 O S.L0'901d 21E, 10 NO US11 X01 H IaV1 MS 1.0N 11 V MIRL ILL -C£ VQIAU);I'QAO}uVS QAV(LJjHog ADJU,r01i4101 S69 AJ'(H' 3 113f0I, 81G111111J$ 11fAI;I WA'I'JVW :AQ 51I11Jl U20AGill1I'JUNIJI AULAU'jHI U:IMd 9NIMOTI013II.I. 2101 AL'I'IVOWDUS QdVE'dd Nd3SI a1VH S,LNWI00Q RKULL ■ ■ ■ ■ uotld[xosoQ olsQ •oN ■ sgoisiAad ■ �o H1'2IDN A - S3''VdS (335o1 -)N3 * SWOON - S),VM 11X3 Z!I3H10 * SS:1' vW IIX3 - 19, - SJ.YM39'v`SS'dd 11X3 � S3,{n50-1'N3 f IIX3 - W31SJ,5 NTNNI'aWG -Ln0 H1.IM - TIUNVVNk IH - W S1N3W3lIIno:iN S3HSIN1� 9N1'1130 is -11VM N01'2131.N1 ° 10Oz'91 d0 3`f9'dl S'SOB 140II'3S N3d BION lrmt `IN - ivm NOIIVN'dd3S 1N VNal '6HI MSN NOIlOn,1.SN00 -1VM 9NIISIX�l NO110n211.SNO7 1-IVM MIN C,: .1)N -1:1 l.l.z/Ozl �J S M S W07 : VINOHII7 'dn-7101f9 J.Z13I 1'd9 'S'a1311A7 4321 '9NISnOH 31VNOGINVOK10d /M N91S 11X3 'C 11 (fI31NnoH '9'1' M3N '(d.11) 12121�l- C13ZI0X� ION-17b'HS N�HSIn9N1iX� 3NI:4 'd 01 71ONa1SIa-1aA'd'61. '7001 -YE: WnWINIW 'V :I9 -17'VHS NIHSIn91SI11X3 3NU MAN Eos NCH X04 N:IHOM ao -i-1'dH S M S HZ91-'VINOHII-1 'dn-71'b'9 J.NauvG '9Z13113 -I 4321 '9NISnOH 311.'VNOGNV'J.7od /M N919 11X3 '(3'3'-f 6131NnoW '970 M3N I � I N I I I I (CI3MO`f7'v' ,O$Z) ,Oz Bol 901 :3n-i'VA 101 W00'c'WOH5 1i s ZZ:/t7 NOUN '59-1 Oir N VHl NaV' IN9 1.H91W SSON9 V HIIM 2100-1=1 �1h09V „z -f7 NO N0076:1 AHI Aho9b 1Rf, NVHl UNOW lO A9 T1VHS 'S9-1 01, NVHl SSA`1 IH91W SSON9 V 9N1/\VH NAHSIn9NUX�l �INW =1O d01 - '1AA=i SL. 4T19XA ION -1-1VH9 NAHSIn9NIiXA �INlA V Ol AONVIG16 -IAnbNl - 9'9ol-,vz WnWINIW V :19 -I-IYHS 9N�IHSIn9NI1X�l 3NI.A - '-1VH9NYH AN I:A �111l KG QaOgN 16 SNO I1�O07 -LY 77b`15N1 CIN V HSINNnJ 'SN�IHS69NI1Xa 4IIA NOS 54z1VQN'V1S '101 bd=4N H11M NI SNAHSIn9NIlX7171NW T1GIVINOd 'z C1AC11/\ONkl 119G 'NIW ,ZG AVA-1 NAd HiOM 11X�[ WnWINIW - 'NIW ,," H1.QIM NOCIINNo0) Nbm9 WnWINIW - 'NIW 1,9G HIOM �rigi v` Nvnio WnWINIW - (NIW HICIIM �loOC1 z4O 110-10 NOOQ NAcA HICIIM ilX�l ,19'11 = (CO) S1N'v'dn000 gG - S1N`v cin990 g5i = S11X�i amnOuN z / S1N`v'dn990 GI I - WaS,15 ',--IA1NN1Nc4G lno H11M ,OSz :AdO'D NAc4 19N'd1Sla -MAV {l - S_LIXA z = S1NYdn990 00G > S1N'Vdn990 GII :acioo NAd S11X�i amnOaN - (C14�--lAINN1Nd9-NON) 9N11.IXA '(d,U..) lddd Sl. Q330X3 iON 11VHS �A3HSIn9NI1X3 3NIA 'v' 01 39N'VISIQ 1AAY'&L 9'901 -VZ: WnWINIW b �19-1-1VHS NAHS69NUX�i �INl=4 MAN (-=I.)N 73 UVOC I N S M S HO -1 :YINOHII-1 'in -719v9 ,121311'd9 'SNaUA-1 491 '9NISnOH 3-LVNO9NV',l-1od /M NOIS IIX3 '(n'3'i 431NnoW '919 M3N �-------1------ - --I - I l I I :19N1d15I6 „o`.f.And. Nil] � J I II I II 1 7T 'NIW NO I - _- i I ® I c-) =.� 'i'�iiii .._J �� .ems I � I ❑ I I J � I I 1 �'NIMI'—rl I f-N!4l�r I II I LJ I k) rL--- - _ _. - .. ... ,. , - __ - - - - - _..-­-----=-.--.- -- - - - -._ .,_. ._ _- _1 rrrril I �� osz)I -OI -/+ __ �1'--)N_IV1.5IQ1711 'NIH I r r F ---i Incz) �4 �a ■ V'1'V'NV11SI2iH0 - &�Lv 'I g00z .LLI']1U,&d0:) 'CTiLLIHIHWd SI NOLLOIlQ02Id32I'SO IlIHO�IV HH.L dO NOLLVdIOLL21Vd QNV'IVAOX(ldV iIII1. ,IHOH,LIM SNOI.LVOO`i uiIII.LO NI 2 O S.L0'901d 21E, 10 NO US11 X01 H IaV1 MS 1.0N 11 V MIRL ILL -C£ VQIAU);I'QAO}uVS QAV(LJjHog ADJU,r01i4101 S69 AJ'(H' 3 113f0I, 81G111111J$ 11fAI;I WA'I'JVW :AQ 51I11Jl U20AGill1I'JUNIJI AULAU'jHI U:IMd 9NIMOTI013II.I. 2101 AL'I'IVOWDUS QdVE'dd Nd3SI a1VH S,LNWI00Q RKULL ■ ■ ■ ■ uotld[xosoQ olsQ •oN ■ sgoisiAad ■ �o H1'2IDN A - S3''VdS (335o1 -)N3 * SWOON - S),VM 11X3 Z!I3H10 * SS:1' vW IIX3 - 19, - SJ.YM39'v`SS'dd 11X3 � S3,{n50-1'N3 f IIX3 - W31SJ,5 NTNNI'aWG -Ln0 H1.IM - TIUNVVNk IH - W S1N3W3lIIno:iN S3HSIN1� 9N1'1130 is -11VM N01'2131.N1 ° 10Oz'91 d0 3`f9'dl S'SOB 140II'3S N3d BION lrmt `IN - ivm NOIIVN'dd3S 1N VNal '6HI MSN NOIlOn,1.SN00 -1VM 9NIISIX�l NO110n211.SNO7 1-IVM MIN C,: .1)N -1:1 l.l.z/Ozl �J S M S W07 : VINOHII7 'dn-7101f9 J.Z13I 1'd9 'S'a1311A7 4321 '9NISnOH 31VNOGINVOK10d /M N91S 11X3 'C 11 (fI31NnoH '9'1' M3N '(d.11) 12121�l- C13ZI0X� ION-17b'HS N�HSIn9N1iX� 3NI:4 'd 01 71ONa1SIa-1aA'd'61. '7001 -YE: WnWINIW 'V :I9 -17'VHS NIHSIn91SI11X3 3NU MAN Eos NCH X04 N:IHOM ao -i-1'dH S M S HZ91-'VINOHII-1 'dn-71'b'9 J.NauvG '9Z13113 -I 4321 '9NISnOH 311.'VNOGNV'J.7od /M N919 11X3 '(3'3'-f 6131NnoW '970 M3N I � I N I I I I (CI3MO`f7'v' ,O$Z) ,Oz Bol 901 :3n-i'VA 101 W00'c'WOH5 1i s ZZ:/t7 NOUN '59-1 Oir N VHl NaV' IN9 1.H91W SSON9 V HIIM 2100-1=1 �1h09V „z -f7 NO N0076:1 AHI Aho9b 1Rf, NVHl UNOW lO A9 T1VHS 'S9-1 01, NVHl SSA`1 IH91W SSON9 V 9N1/\VH NAHSIn9NUX�l �INW =1O d01 - '1AA=i SL. 4T19XA ION -1-1VH9 NAHSIn9NIiXA �INlA V Ol AONVIG16 -IAnbNl - 9'9ol-,vz WnWINIW V :19 -I-IYHS 9N�IHSIn9NI1X�l 3NI.A - '-1VH9NYH AN I:A �111l KG QaOgN 16 SNO I1�O07 -LY 77b`15N1 CIN V HSINNnJ 'SN�IHS69NI1Xa 4IIA NOS 54z1VQN'V1S '101 bd=4N H11M NI SNAHSIn9NIlX7171NW T1GIVINOd 'z C1AC11/\ONkl 119G 'NIW ,ZG AVA-1 NAd HiOM 11X�[ WnWINIW - 'NIW ,," H1.QIM NOCIINNo0) Nbm9 WnWINIW - 'NIW 1,9G HIOM �rigi v` Nvnio WnWINIW - (NIW HICIIM �loOC1 z4O 110-10 NOOQ NAcA HICIIM ilX�l ,19'11 = (CO) S1N'v'dn000 gG - S1N`v cin990 g5i = S11X�i amnOuN z / S1N`v'dn990 GI I - WaS,15 ',--IA1NN1Nc4G lno H11M ,OSz :AdO'D NAc4 19N'd1Sla -MAV {l - S_LIXA z = S1NYdn990 00G > S1N'Vdn990 GII :acioo NAd S11X�i amnOaN - (C14�--lAINN1Nd9-NON) 9N11.IXA '(d,U..) lddd Sl. Q330X3 iON 11VHS �A3HSIn9NI1X3 3NIA 'v' 01 39N'VISIQ 1AAY'&L 9'901 -VZ: WnWINIW b �19-1-1VHS NAHS69NUX�i �INl=4 MAN (-=I.)N 73 UVOC I N S M S HO -1 :YINOHII-1 'in -719v9 ,121311'd9 'SNaUA-1 491 '9NISnOH 3-LVNO9NV',l-1od /M NOIS IIX3 '(n'3'i 431NnoW '919 M3N �-------1------ - --I - I l I I :19N1d15I6 „o`.f.And. Nil] � J I II I II 1 7T 'NIW NO I - _- i I ® I c-) =.� 'i'�iiii .._J �� .ems I � I ❑ I I J � I I 1 �'NIMI'—rl I f-N!4l�r I II I LJ I k) rL--- - _ _. - .. ... ,. , - __ - - - - - _..-­-----=-.--.- -- - - - -._ .,_. ._ _- _1 rrrril I �� osz)I -OI -/+ __ �1'--)N_IV1.5IQ1711 'NIH I r ('S'I'N) 1N'dN�11 1N�1' ')IVP V (S-'d/trl 71'dl�q '�I) H91H 1,trS 'XVH 11.9 :1(3IM 1195 °71534 Z13WO1Sn0 �O NOII'24Od 319155399V (dJ L) 1334 SL (3330X3 -LON TI'VHS NJ iHSIn9NI.LX3 =Nle 'V 01 3'NVIS14 -]:IA X11. 9'901-VZ7 WnWINIW 'V �I9 TIVH5 a13HSIn9NI-LX3 3NW MSN I I I I I I I Nvjd SsrL-lx r ('S'I'N) 1N'dN�11 1N�1' ')IVP V (S-'d/trl 71'dl�q '�I) H91H 1,trS 'XVH 11.9 :1(3IM 1195 °71534 Z13WO1Sn0 �O NOII'24Od 319155399V (dJ L) 1334 SL (3330X3 -LON TI'VHS NJ iHSIn9NI.LX3 =Nle 'V 01 3'NVIS14 -]:IA X11. 9'901-VZ7 WnWINIW 'V �I9 TIVH5 a13HSIn9NI-LX3 3NW MSN I I I I I I I Nvjd SsrL-lx r"Vi �-�knnt 11% A Ouick Guide Cr.>rltact U3 II Fire 1044tarrU Riltitig-, - ANSLIlUt, 26JI E-4 ape � P12Lt Q 111 VV4"lil I ) Li8age Disidaircilic Autliojitie� I-lavill )Iluri,�,lictlorl :ihok)ld il conuAltit"ej In all urt'llk" d'� to IM paIrtickilar fu(j'airilftlents, i:o*,'4.0fjjIo tho drid usmil of UL Usted or Cloissified produ�cts, eqjuipirnsjot, 5y'iU-Ofn�i deACC5, mi Materials, Autillorides Having )urisdiction should oe consultvid batil construction. FIre resistance a5secriblies arid prooncts ale div/eloped oyI' tile, desiI SUbirfitter ailid have beef) investigated by 1I for coil 1ph affice 'eirill apolicauNk riiv pvulisiml linforinatill ctinnOt alliIIII addr(.,zitv41iy toilstructivo nuancle encouriterold if) the fi(.1hi. When field iss,,,jes arise, It is reconfrriended t�he Il contact for a5FJs"ncP, be the LtIChnical service 511 pro�jl by the trwfivilat:turve nutiw for tile (wojo, u!;lII or rice asionitAik"; dro od'ml to cufli5ult OM fliellordl Goldj! InfQrryi4jti,on fair each pircouct citlarjory and e-jdl (proup of asserllbliek;, Itle rjuill lnlorrt-�abufi IncluiI 1pecifics cli rig afternate rnlaterlat5 ard alternate methods of con,3tructlon. Only products wtilch bear VII Matk ,ire considered arm Cla�ssifje(IJ, I.Isted, or, R-2CU(jr) 14ed. 11"Iry Riislstmiirc� [(if I higi - kNSV U L, 20 4 111 10L 5A LJL L' Design No, U419 No-,lIernber 14, 2007 NVAIJ IN(l4q,"i ---- 1, 2, 3 irt-4 It V ("SVV, Items 1 A 24 1. Floor and Ceiling Runners - (Not shlown) - For Lj,.,A, eotn Itern 2 - Channial shaped, fabi icated frorn rnin 25 II steel, mlrj vildth to, aCcuniniod,'ite stud slie, with Artier I Ili,, long legs, attadie-0 to floor Ijko cciling with fasWnets 214 It), W imix. 1A, Floor arid Ceiling Runners', - Not s�vml - lit ticAu of Item I For uIse itilith Rem ZA, proprietary channel 11, 1 Ell 5 -W FIR film <11 as rifitill';, ml oil I'll At �i'l�'I'l.,�i���'ll�.��!�r�9]kglqi,tug!l!l���olzi�ltvt",kl",-.'�l�I N It Vialied, tylln, .*J-$/6 in. wide. with I in. long I4,qs, raoficattel from 111411111, (M)1,50 Im (0,64� In" Iiiiii oare froeltat thiiCktics�l' 0aiViiiii,4001 I'Letli, attachl;W tu fk�or 4nd Wfitw witi, raswo-oit., ?,i Ili. oc. rlricc DIETRICH INDUSTRIES INC ---- 11,11traSTEE'J.0. 15. Floor and Ceiling Runner:% - (Not shoart - In l6eu of III Fat, use with Itern 2A, proprietary ch,annel �hjped, lilln. 2-9/16 ill. ajdu -iiolitilit 1-3/ifi In. limi flanotm fourltated from rnin. 0,01I Ili, golydnized stil attached to floor ll:ind ceiling fjsteners� 24 In. OC, nwx, DIETRICH INDUSTRIES INC - UltraSTEI�L-5,0. 2. Stool Studt - Charitil shoi'�iid, rablricite(i froin) linin 25 M1jG cot roi5lonk prOtentuo 5to,6-tl, intin le4iifftlik as Inidicall'i ull [tern 5. 111 1 -IM in. flanges aild, 1/4 in, rlatuf'n, SPaIC'ed 6 1114A Of 24 it), QC, Stumi to be Cut 3/13 to 31A iln� less than assembly hialpt. )A. Stooll Stlarls'lli - In fieu of Itern 2 - Pospriet"aly chanliell shaped situds, min. as indlt;ateo uriall�zr Itenj 5, inirl. 1-1/4 iri� kxig Ili 11 1/4 Ili, tonel toklifid back rL�turn floiI hNs, fabritI III inin, 0,0155irl, (0,0J49 In., rhin b;jre metal thickiless) galvianized �teef, At 111�1;4 of 2,t ini tjC,� Stud-, to be cut 3/8 to V4 in, less than assianibly height, Mo,elfable use of studs is shom�m if) Lhe table below. Por direct attach,ment of gypsum boaid only� DIETRICH INDUSTRIES INC -L Ultra5TEELII 28. Steel Studs - (As an alternaLe to itern. 2v Fisr- use wlth tLent S15) Channel rhaped, fabricated from rnrn 20 r-lsG (Q�Ojv Ill. thirjk) ('01,105lon-protected of- galvs6e,00, 3-1/2 in. inin M-00), min I -t/2 In. flanges and 1/4 Ili. retutit, olpaoid d inax uf I& im� CC, studs frictionl-fit InJI floor and ol rurinwi;, Studs to Do Cut. 5/8 to 3/4 Ili. IsiII 1rharl mi�,��elrlbly height, 3, Wood Structuial Panel Sheathing - (OpUonail, For use: ill Item 5 01)ly,)- (Plot Shrni - 4 tLyetcle, l/V5 alrafl(j board (050) of, L$02 WII, tril 5til'11,41dul'il I (pliI0900d) C0111plying-Vil Q0C PSI on Pf-52, or,APA St4ndard PRP-iOO, 1116006(.11,111 With 0Attjrjj;;r Ulk1Q, oppliki(I jjOrj4ojj(,)JIy ojjrNQttjC4j)Iy to tnt) 51 studs. Vartical, joint$ tenteored on stull and one stud space fron) wallboard joints, Attairlied to stud-. livith flat-hemad self -drillit-to tapping si �ntth, a rnin. head diam- of 0.292 in, at maminum 6 1 11 in the perialeter an4i 12 in, QC, Ili the field. 4. Gattt litiful BlAinkults'll' - (Ru44kiii-0 all indiclitud under 111 5) 1- Pfilletal wuwl UdLtO,, III fit1.0J blit-mvelm 5tL1-1 arld ruriners, Min niorn thickness -i:; indicatill urider item 5. Ste Batts and Blankets (OKNV or DZJZ,) Categories for names of ClassItied companies. 4A. Batts and Blanketsi - (Optiorhil) - folaced in stud calm,itles, any glass fibmar of, nirrieral i/tool Insulation lAil)(ill Ulti I CWsiricaLloll P43111kinli ml� tO rjiutfatj� ChIl3ractarlstics as'Wlor Firel RO:&400hCO,� Sell Batts and Blankets �UKNV or BZJZ) Categories for nornes of Cumissifiej r.,ompwinjes. r' 5. Gypsum Board* - Gypsum ponels with oe-yeled, !V4udrq or taper'led erj,?es, apiplied 'ierrically oir hoeirontally, Veitical jolints centered oqer studs arid' staggered one Stuld ca�,jtyr 01.1 ll)ppo$jte,� III of StIl 'Vertic I t . 5 a I jloin .5 it I adjacent layets (multIlliyer, staggered, one stuid ca-Ifity. Horizontal jo-inta ji,eetj riot be oacked: t)y st,eel frifirning. i'lorizoli(xil edve juints arid hUrizointal butt joillts Of') oppoItmite skWs of VtWti nolild riot be Staijl 1-1cirizontal VJge jii and hillori;zontal Uuttjoints Ili adjacent layers (multdayer systems) staggered a mlin of 12 lrl� 'File thickoes5 an<1 numoet, olf layers foe, th.11 I hil", 2 lir, -� hrI 4 lu rallinil are a5 follomilli min Min No. of Min stud Stud 1.4yeirs Thkns of Rating Dopth, Depth, &'Thkins Insulation Item 2 Item 2A of Panel (Item 4) 11 1/2 1 loyer, 5/0 In, U116N. Qptio III 1- 112 in, 1/2 1 Ilayer, 1/2 In. 1I L-5/8 3-5/8 1 Idyer, 3/4 In. t UL -RIATED ASSEMBLY LISTING (U419 - i TO 4 HOUR) I � 2 1, - 50/_8 2- 1"/ 2 111' 112 Ili. thicilk OptiQll'il . . . .................. 2' 2 layer5, 5/8 In. thi Optional j � 112 3,51,5 1 layeoir, 3/4 In, thirk 3 In, 1-5/b 2-1/2 3 taijer5l, 1/2 In. thick Optional 2-1/2 layer -5, 3/4 in, thick I . ....... . . 2-1/2 3 1 f, 0 It J, 5/i -if -,I, it layers, 51V in. Optional 1 5/8 2-1/2 4 lalvors, 1/2 in. I Optionall ill rc k 2-1/2 2-1/2 2 IdyerS,r �3/4 Ili. (hick - CANADIAN GYPSVM COMPANY - 1/2 in. thick Type C, IP -'.,(2 or ]PIC -AR; WRIC, 5/8 Ili, thick 'rype AR, C, IP, - ARA III IP -X2, 11"C -AIR, 511 SHX, 'i Or 1oVRC,' 314 in, thick Typq�; IP-X�j Or UL-TRACGDE UNITED STATES GYPSUM Co - 112 iri� tirlick'rype c, w -X2, li�v,:-AR or lilml 5/8 in� ti,flick ryf4, -cOlix, NRX, (R -XI, AR, C, Vi FR:<-(,-�, IP -AR, 11I IPC -AR ; 3/4 im thle.,k'Pil IP -X3 or ULTRACME USG MEXICO S A DE C V - 1/2 in, twick rvpe c, t1I WC -AR or lfikC; 518 Ili. thick I ype lil C, W -AR, Ifl- Xj, [P -X2, IPI SC�% !;+IX, Iiii Vi Of'; 314 In. thicle, -Types (P`4�3 0-1 111 ['PACO D E "Alhert ILlil 7B, Steel Framing 6lembersill, Is used, Oncribearing Will Rating Is firnited to 1, 1-1r. 11I stud depth ts 3. 112 in,, min. tnickness of insulation (ftern 4) 15 3 in., arid two layers olfgyrisun) tol panels ( 1,/2 in I. or 5/8 In. thick) 0dll be 41t,dcheo to furring a, dor,;crioed In It0fr''i (5� Glou layul of gyplill bli 0,3riliI (1,12 in. or 5/8 ini. thick) a"af:hll to oppiII iide of t4ud, oriltriout furring -litirtirtsliIs is deiorlot�d in ItQrn 6. 5A. Gypsurn, Board#, - (As an all ternate to Item 5) -- 5/8 11 JI '24 to 54 in. villide, applied hor)zonWIjIrk as the outer iayer to one side '011 1 ass'eloull/I. Secured as dinsc(lued In I(ern 6. CANADIAN GYPSUM COMPANY - 'rype l UNITEU STATES GYPSUM CO - rype FfkX-G, Si-iX, USQ MEXICO 5 A DE C V -l-, Type $1 V. 515. Gypsuria Board im - (mm an alten-)ate to Item 1; whom w;sed as III base layer, on one,or, looth sfides of mvi For diruct aLtachniont ofIIIII i'mol, to ul" ii ellith Ittlin 3) - NO1,11 5/8 in. thick lea"d backod rj-I poomI 'I bevetpd, �qutjre or t6pqred toliI applied IierllcdhY� Vestical jQrrit3 centered cll,ier 3tuill �nrj 5taggeredi rnin I stud ca-Aty on opposite sides lot 7,Ituds, '01-jiboard securelcito stuldsMitli 1-114 tit, long Type! S- 12 steell scre"'I spialt.'ed 8 lrl� 10C, it Pt-l6nWWl' I.'jntl 12 in,, OC ill 1111I fitildl� RAY -BAR ENGINEERING CORP' -Til R6-1.1315 6. Fastenets - (Not shovilln) - For, use wiLh I tern 2 - Type � or S- 12 steel screws uscd to attach panels to titud!; (Itenrl 2),or full-ri-VIQ chann-I (Ition 7). Single layer syStemst I icli. long for 1/2 an -d 516 ill, thi(k poncis or 1-1/4, Jai III for 3/4 in. thickplawl slpac*d 8 in. OC whi3n pallials are applied h(,mzQf-Iti ill 8 11m, OC allong: i/ertical and olottorn edq�lms and 12 in, QC In the filaid when panels are applied vertically, Two layer systerns: First layer- I if),. long tot, 1/�� aii Solli in. thlol Panels of 1-1/4 In. long for 3/t in, tljllc�,, 1),inels, spaceir.1 16 jjj� it")C, Ill ing for, 3/4 iol, thiCkpanOlIll, lf) of, 2. 11 . I( III 0-c'o,mith, screws oll 84t, froril first layer. 1-hroe-layer systems: First fayer- I Ili. long for 1/2 in,., 5/8 In, pariels, spaced 24 It). OC. E`Aacond layes- E-5/8 ii'), lorlig foe 1/2 Ili., 5/0 lri� thick, pariels, spactI 24 it), Qc, Third ld,il 2-1/4 irt. long lor II in., 5/c 101, thick paomil or 2-5/8, ill, III for 5/113 iii. thitl< p,�lnels, spaced 12, ill, 0c, screw#s oiiI� tillin, 6 Im front Idyer belil PoUlf-layer systerns: F45( )a -I I Ink lung for 1/2 it),, 5/8 In. thle-k parI spaiced 24 in. OC. Second )ayer- 1-5/0" In, loll for 112 In,, 5/8 In. thick parl SpaCed 24 IM 0C, Pill II Im NMI 6, I,� g t : l0 ll� 4 Art milulm' Olt kl' 4 iii l!j I a it :j I A I IIIIre, 1.,..11Qjlll ik" Ck Air lit Tlfl�"d layer- 2-1/0-1 in. long for 112 In, thick panels of- 2-5/8 Ili, Jon(j for 5/U in. thick pariels, spill 2it in. (>C. Fourth Ill 2-5/0 in. 1,witj for 1/2 lit, thiCk paoiflGbi 3 it). III f0f 5/8 Iti, thitk Vdol)Vl�, s'[)dCed 12 1 ir. QC. S<rews offset min 6. in. front layer Weyer, ii Fastener s -- (Not shollil -- For tr��4 with Itern ZA , Type S or S- 12 Steel 3r.1`4�'IWSO U�ed to attach P'llimi s to syl (Irefir 2), Single layer systems: I It), long for Il2 and 618 in, duck panels or 1-1/4 In, li:�nq fil 3/4 In. III P4114fl,", qiracod 8-112 ill, 0C with additiorlial wows, I In, 11 2-1/2 ill. frorl'i i;I(I Qf the Word iiii panels are hoirizonti or 8 in, QC, dIWq ��42rtical and bottonn edges arid 12 in. CC in tile field wherl pallefs are applied verticaliyl. Tyeo layer systems applied IdertIcally: Fli-st layer- 1, in. long for 112 and 5/8 111 till painels of' 1-1/4 if),, long for 3/4 In. thick panel.5, spacea 16 irt, OC, 5econd layer- Ionq lot, 112 in., $1 U Ili, (Itick paif`I06 Qr 2-1/4 in. looij for 3/4 in. thi0l; panels, 60alwd tO ill. 0C, Iiii,01th 5CIrtill ofN4A a In, front firkst farw-. Two layer systems applied horizontally: First I in, long for 1/2 and 5/8 in, tJI pilriells or 1- 1/4 If). long for 3/4 In. thick panels, spaced 1(5 In, CC Starting 6 In. from each edge of tile board with ain b0ditional SmCrtre placud I. t/4 in, floull Qla(b 0(fill of II U(I 5414�0;lrdl livy'&I 1-5/0 Ili., long tot" 112 41�, 5/6 in, thicil, panels or 2-1/4 jI long for 3/4 fri� Chick parlels, spaced III im 0C starting a Im froln each All of thiri board mlil all additional screw pfaced I - 1/41 in. from each ell of the t�cljlrd with screws offset 6 In. frtijul first layer. Three-layor systernst First 111 1 in. 10119 IfI 1/2 4, �jd In. thick paiI spaced 24 in. OC. Second Idyvr- 1- 5/0 Ili, long 111 112 Ill., 510 in. thick paotils, olidtAid ter. OC - 'rhiriI laydr- 2-1/4 fit. long for, 1/2 Ill., 5/8 in. thick paritis or 21,518 if), lill for 5/8 Jim thick p-joels, 5poclad 1.2 in, 0C, Screws offnqt rnin 6 in, from layer belci Fair all layers, an additional cTlamq shall be placed 1-1/4 in. frorn each edge of tile board. Flout- layor systernst First layer- I in,, long licif 1/2 in., 5/8 10, Wick Panel$, spaced 24 lit. CC. Secoffildi 111 1-5/8 InI, long for 1/2 in,, 5/8 in, thick partI s;pAl 24 Ili, DC, rhirld layol 2-1/4 in. long for 1/2 In, thick panels or 2- 5/8 in, long for 5/;� in, thick panels, spacialoll 24 Ili. iOC, rourth laijer- 2-5/8 im loinq fell, 1/2 in. thick panels ll 3 In. los'ej for' 5/8 In. thick panels, spaced 12 in. 0C. 5ctleivs oll 116 Ill froill la -I oeloeil For all layers, an additional v.row 'Jhall b -G- Illil 1-1/4 iij, froln, o6ch udge of tile boitird. 7, Furring Chmannalu - (Optilritial, riot ta)oml for sinulo or doublo Itiyer t;ysturns) _ R4j�jIjrlIIt fkjrlrillfj fabilill horn min 25 MSG co(rusion-protected steel, spaced vertically a max of 241 in. 0C. Flan ge portion attached to each Intersecting stuo with 1/2 In. long Type 5- 12 steel svlews� Not. for I mith I(efri $A� 7A. Steel Framing Members (Not Sholyl * - (f)ptiiarlial 01) one or Datri, slldiI ;riot shown, to(, cer dwille layur sy3tovns) --I� A�j 611 "ilternitia to Itern 7, furrilr4j chanfiels arld Stifiel Frainjou mitinoers as destribud bel -ow: a. Purring Channels - Formedof No, 25, M5XI; ill steeL 2-3/8 fill, �,ajde by 718 In. deep, spacedl rnax�. 2el Ili, GC peirpleridliculat, to Chatirielis se-citifed to studs, a5 descilc-ed in Iturn, �- Glyp��uin b-oatcl to furring f:hdll(l0I as desictibud in Resn, 6., Not tot uoljj Vilith ltil 5A, b. Steel Framing Mmaimbersill' ��- Uscd to dt0ch furring clu3nnels ([tern Ma) to studs (Itein 2). Clips spaced max, 48 im 0C. RSIC-1 clips secured to studs With 1118 x 1-1./2 1 Illiniftl S-1,2 �mcre�if throillgh tho centor groinfriet. R51C-V diln &ecurfl w 5tud; with (1 0 x 9116 it). laillifflum imilf-drilling, S- 12 steel streilly thr(�ugh the cmirlw hole. Furring channels are friction fitted into dips. PAC INTERNATIONAL INC - Types RSIC-1, RSIC-1,0', 78. Steel Framing Members (Optional, Not Shown)" -- As dill alternate to III '?, furring channels arid Steel' Frarn-ing Members on only title side of stud -5 as described belokill a. Fulling Channels - Formed of No. 25 MSG galillik siI spaced 24 Ili, OC pqrplandicular, to studs. Channels secured to soulds as deicilbed in Itern 0. (latt'll and 131ankets pra, ce<1 Ili ,�tud raivilty aI� In Item 5. "Ti.4001 4ilecur-5 Of fjyjowin board atiddicd to ruving criannels as des/.xibeel in item 5, Not tor ii witti, ItIeni Sok, b, Steel Ff anning Members 4 - Used to attach furring channels, (Item )6a) to one side of studs (Iteln 2) 1)(111101 Clips spdCed 48 in. OC., and secured to s(udsmill, tivo I a x 2-1/2 Ill.. codrsw dirywail tXre%Y3, 000! 1.1"WoUgh tJI holo ill edch tInd of (Iiie thp. Futrinrj cridarlili are friction fitted into III KINETICS NOISE CONTROL INC - type Isonlax U. .11011. To" and Clompoun(l - N/Orri or Cdt;4rIiti, fjl yr of, JA r,t� $1,111, I'K Old jil oultipoulid al.lplitird In two, to j%�Jrlts and scre�l heads or oll la yers. Pa,plertape, num 2 in, wide, ofIr)J.il'L,�,j(jq0d In first Jayer Of c .qrjljj( surld vi aft jolrW; of outer lwyer p a net s. Paper tape arid ;c -Int ccfripound I be orrikted svirien gyps,uni panels are supplied mmflth a 41, I il,q jj,� �111 4�, I'l I'MIR", in III Ill! IR! Phil 11:1!l� 11511IID'il, A r lJAI (4 11 '011 WOI% 1 4l,o, Ill )�A � I I III I: P X Il� ll�:::�A1111111,1 111""M 4680l!ll: 211111illilll!", ft k fk- VA431 foul I1 liquP, '411fmiji,f iiiie �; 104 A, illp � �J: l"t, i, ��w 1.'fIV41Sll-1. 101 Revisions No. Date Description A01.22 -200a LL CIQMMT5 rHESE DOCUMENTS f IAVE BEEN PREPARED SPECIFICALLY FOP, TIE FOLLOWING PROJECT., tnteriorT eii Improvements for: Mattress firm SefiliflotbTulm Cpaiter 695'lofm Cepiter BoRtevarb sailforb, 1-foriba 3Z771 T�IEY ARE NOT SUITABLE WR USE ON OTHER I!RQJEUI� 04 IN Ol LOCATIONS WITHOUT THE, APPROVAL AND PARTICIPATION O1,T HE AXICHITECT, REPRODUCTION IS PROHIBIT ED, COP YRIG11T 9 oo8 LAXXY L, CHPUSTIAN� A.T.A, 4-J Qj tzs 4 - CS lit 01I Lary Llit 4 0 C ristian AlAs 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 1, 2 , F�) ob Expire8: 02.28.09 Larry L. Chriirtiatil A,I , A. Florida Architectural Registrati #AR -0010755 Oul Ul- DIRECTORY IL15TINO SHEET A-05 Date: 07.28.2008 Project No. 0805-776 I ROOM FINISH 50H tUL ROOM NO, ROOM NAME FLOOR BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL GEILING REMARKS FINI5H HEIGHT 101 SHOWROOM RE: PLAN R5-1 RE: 5HT. A-4 RE: 5HT. A-4 RE: 5HT. A-4 RE: 5HT. A-4 AG -I I2'-0" A.F.F. TOTAL:L.- 102 HALL VGT-1 V13-1 P-5 P-5 P-5 P-5 P-1 10'-D" A.F.F. -- 103 MEN VGT-I V15-1 FRP-I, P-5 PRP -I, P-5 PRP -11 P-5 PRP -I, P-5 AG -I q' -O" A.F.F. RE: 5HT. A-5 104 WOMEN VCT -I V15-1 FRP-1, P-5 PRP -I, P-5 PRP -11 P-5 PRP -1, P-5 AG -I q' -O" A.F.F. RE: 5HT. A-5 105 FILES/REGORDS VGT-I V15-1 P-5 P-5 P-5 P-5 AG -I 12'-0" A.P.P. 106 VALUE GENTER PL -I -- P-5 P-5 P-5 P-5 AG -I V -q" A.F.F. L-1 f-' I N I SH HAA VAR LNr;) HINGES: LOCK SETS: B -I: NON REMOVABLE PIN L -I: PRIVAGY SET B-2: REMOVABLE PIN L-2: OFFICE SET B-3: DOUBLE AGTING 1--3: STORAGE SET L-4: DEAD13OLT LOCK L-5: STOREFRONT ENTRY; GLOSER5: THUMB LATCH 4 FLUSH BOLT G-1: PU5H SIDE L-6: CHAIN H015T 4 PADLOCK G-2: PULL 51DE L-7: PANIC, RELEASE EXIT DEVICE L-8 NON-LOGKABLE PASSAGE SET � KICK PLATES. P-1: PUSH PLATE I: 24 TALL x DOOR WIDTH P-2: PULL HANDLE - MINUS 2", INSTALL ON BOTH 51DE5 OF DOOR DOOR STOPS: 5-1: WALL MOUNTED BUMPER K-2: 10" TALL x DOOR WIDTH 5-2: FLOOR MOUNTED DOME MINUS 2", INSTALL ON 5-3: INTEGRAL GLOSER STOP BOTH SIDES OF DOOR W/ WIND RESTRAINT OI/A-6 (SIM.) I I I 1 1_ I I l I _ I I I _ SHOWROOM 1� I 5/8" GYP. BOARD ON 1 t `y 3-5/8" METAL STUDS @ I 1 16- O.G. (PAINT) >'v I 4 I 1 Q BOTTOM OF FURR-DOWNIlk I -q' A.F.P. — — — m 4 : T LINE OF VALUE CENTER WING WALL (BEYOND) SECTIONAL PRE -FABRICATED VALUE CENTER PLATF=ORM TO > BE PROVIDED BY OTHERS a SCHEDULED FLOORING AND BASE (RE: PLAN) 011 TOP OF STEEL f 19'-4" A.F.F. FIELD VERIFY BOTTOM OF STEEL f 17'-4" A.F.F. DIAGONAL BRACING AS REQUIRED 4'- 2 LAMP FLUORESCENT STRIP LIGHT, MOUNT END TO END DONT. (RE: 'D' 02/A-3) CLEARANCE 5/5" GYP. BOARD ON 3-5/5" METAL STUDS 16" O.G. (PAINT) WOOD BLOCKING FOR TENANT FURNISHED, G.G. INSTALLED METAL GUIDES; VERIFY MOUNTING HEIGHT WITH TENANT SECTION AT VALUE CENTER 1/2" = 1'-0" 0 53'-11/4' 6q'-4 3/4" G.G. TO PROVIDE 2-LAYER5 3-5/8" TYPE 'X' GYP BOARD (EACH SIDE) OVER EXISTING 6" AND CONTINUE TO UNDERSIDE OF EXISTING ROOF DECK. FINISH AS SCHEDULED. (2 -HOUR FIRE RATED PER UL DESIGN NO.: U41q). FURR OUT EXISTING COLUMN WITH 3-5/8" METAL STUD 4 5/8" TYPE "X" GYP. BOARD (FINISH AS SCHEDULED) (TYR) ADJACENT TENANT 31-01, W-21/2" LINE OF IMPLIED CIRCULATION PATH THROUGH SHOWROOM BOOR �G4UJ� -1 (®JEI FIELD VERIFY FIELD VERIFY VALUE700 TOP OF STEEL i TOP OF STEEL GENTEfz t 18 -4" A.F.F. _t 17'-4" A.F.F. FIELD VERIFY 106 FIELD VERIFY DETAILS BOTTOM OF STEEL BOTTOM OF STEEL t 17"-4" A.F.F. f 16'-4" A.F.F. DIMEN51ON5 CONSTRUCTION +/- l8 5q. ft. TOTAL:L.- NO. TYPE SIZE (W X H) TH'K. DOOR FRAME DESCRIPTION 101 -- PR. 3'-0" X -t'-o" -- ALUM. 4 6LA55 ALUM. B-1 L-5 S-3 C-1 0 0 0 1,2,3 ENTRY 102 -- PR. 3'-0" X l' -O" 1 3/4" HOLLOW MTL. H.M. B-1 L-7 S-3 C-1 0 0 0 0 1,2,3 HALL 103 -- 3'-0" X 7'-0" 1 3/4" HOLLOW GORE M. WOOD B-2 L-1 S-2 C-1 K-2 14/A-6 3,4,5 MEN 104 -- 3'-0" X l' -O" 1 3/4" HOLLOW GORE WD. WOOD B-2 L-1 S-2 C-1 K-2 _ _ 14/A-6 3,4,5 WOMEN 105 -- 3'-0" X l' -O" 1 3/4" HOLLOW GORE WD, WOOD B-2 I L-3 S-1 C-2 K-2 14/A-6 3,4,5 FILE5/RECORD5 REMARKS: I. FXI5TINO DOOR - VERIFY ALL HARDWARE 15 PROVIDED AND IN WORKING ORDER; G.G. TO REPLACE ALL WORN OR DAMAGED DOOR HARDWARE INGLUDING BUT NOT LIMITED TO: DOOR HANDLES, LATCHES, LOOKS, CLOSERS, KICK PLATES, ETC_ TO MATCH EXISTING BUILDING/SHOPPING CENTER STANDARD, 2. A SIGN READING 'THIS (OR THESE) POOR(S) SHALL REMAIN UNLOCKED DURING BUSINESS HOURS. 516N SHALL CONSIST OF ONE INCH (I") HIGH BLACK LETTERS MOUNTED AT 5'-O" A.F.F. 3. ALL DOOR HARDWARE AND ITS OPERATION SHALL COMPLY WITH F.B.G. II -4.13 DOORS. 4. HOLD BOTTOM OF DOOR I A.F.F. 5. DOOR TO BE PAINTED WITH SEMI -61-055 ENAMEL OF THE SAME COLOR AS THE WALL ON WHICH THE DOOR IS IN5TALLED. (UNLESS OTHERWISE NOTED) 6. REMOVE ALL ENTRY/EXIT HARDWARE AND LOGK DOOR SHUT. NOTE: G.G. TO ENSURE ALL DOOR HANDLES, PULLS, ETC,. MUST BE EASILY GRASPABLE AND OPERABLE (I.E. LEVER HANDLES) PER F.B.C. II -4.13.q f-' I N I SH HAA VAR LNr;) HINGES: LOCK SETS: B -I: NON REMOVABLE PIN L -I: PRIVAGY SET B-2: REMOVABLE PIN L-2: OFFICE SET B-3: DOUBLE AGTING 1--3: STORAGE SET L-4: DEAD13OLT LOCK L-5: STOREFRONT ENTRY; GLOSER5: THUMB LATCH 4 FLUSH BOLT G-1: PU5H SIDE L-6: CHAIN H015T 4 PADLOCK G-2: PULL 51DE L-7: PANIC, RELEASE EXIT DEVICE L-8 NON-LOGKABLE PASSAGE SET � KICK PLATES. P-1: PUSH PLATE I: 24 TALL x DOOR WIDTH P-2: PULL HANDLE - MINUS 2", INSTALL ON BOTH 51DE5 OF DOOR DOOR STOPS: 5-1: WALL MOUNTED BUMPER K-2: 10" TALL x DOOR WIDTH 5-2: FLOOR MOUNTED DOME MINUS 2", INSTALL ON 5-3: INTEGRAL GLOSER STOP BOTH SIDES OF DOOR W/ WIND RESTRAINT OI/A-6 (SIM.) I I I 1 1_ I I l I _ I I I _ SHOWROOM 1� I 5/8" GYP. BOARD ON 1 t `y 3-5/8" METAL STUDS @ I 1 16- O.G. (PAINT) >'v I 4 I 1 Q BOTTOM OF FURR-DOWNIlk I -q' A.F.P. — — — m 4 : T LINE OF VALUE CENTER WING WALL (BEYOND) SECTIONAL PRE -FABRICATED VALUE CENTER PLATF=ORM TO > BE PROVIDED BY OTHERS a SCHEDULED FLOORING AND BASE (RE: PLAN) 011 TOP OF STEEL f 19'-4" A.F.F. FIELD VERIFY BOTTOM OF STEEL f 17'-4" A.F.F. DIAGONAL BRACING AS REQUIRED 4'- 2 LAMP FLUORESCENT STRIP LIGHT, MOUNT END TO END DONT. (RE: 'D' 02/A-3) CLEARANCE 5/5" GYP. BOARD ON 3-5/5" METAL STUDS 16" O.G. (PAINT) WOOD BLOCKING FOR TENANT FURNISHED, G.G. INSTALLED METAL GUIDES; VERIFY MOUNTING HEIGHT WITH TENANT SECTION AT VALUE CENTER 1/2" = 1'-0" 0 53'-11/4' 6q'-4 3/4" G.G. TO PROVIDE 2-LAYER5 3-5/8" TYPE 'X' GYP BOARD (EACH SIDE) OVER EXISTING 6" AND CONTINUE TO UNDERSIDE OF EXISTING ROOF DECK. FINISH AS SCHEDULED. (2 -HOUR FIRE RATED PER UL DESIGN NO.: U41q). FURR OUT EXISTING COLUMN WITH 3-5/8" METAL STUD 4 5/8" TYPE "X" GYP. BOARD (FINISH AS SCHEDULED) (TYR) ADJACENT TENANT 31-01, W-21/2" LINE OF IMPLIED CIRCULATION PATH THROUGH SHOWROOM 02 -1 (®JEI FIELD VERIFY FIELD VERIFY VALUE700 TOP OF STEEL TDP OF STEEL TOP OF STEEL GENTEfz t 18 -4" A.F.F. _t 17'-4" A.F.F. FIELD VERIFY 106 FIELD VERIFY I' BOTTOM OF STEEL BOTTOM OF STEEL t 17"-4" A.F.F. f 16'-4" A.F.F. t 15'-4" A.F.F. VALUE CENTER +/- l8 5q. ft. TOTAL:L.- xx > P-4, P-5, R15-1 P-4, P-5, M-1 I p% o I I I i i ;�,, - -I / G I I1 O i CL V-10 1/4" 1 3-o .,-0. 4'11 G -I OI/A4 G -I I 123' -OI 1/2" 13' O" 32'-11 1/4" ; ; E p/� l LINE OF ALUMINUM SUNSHADE (ABOVE). I I f II I -__-_ S N G.TERIO PROV DI SATED (%i ,1 % I i i , I I 11 ELECTRICAL. (TYP) t I PROVIDE NEW 4" I � o - - �- - MATTRE55 0 1 °" I I I I 4 � � � BLAGK/BROWN KOPPE FIRM RM 1 1 ------ --�-- I I 10 RUBBER BASE THROUGHOUT II 1 _ I 1 5HOWROOM AREA (TYP.) I 1 M 3 IQ - 0 �� O 13'-10 3/4" I 6 0" I I 6-1 �k 03/A4 al IF LI G -I 1 a 1{} 13; F ---------�_j 1 I I G 1 D I 1 __ m i � 1 -- - - D_ o i L O G -I p G -I I CC, G i G.G. TO ENSURE: 5% RUNNING SLOPE MAX,2% GROSS SLOPE MAX, 1/2" ELEVATION CHANGE MAX ATLANDING (TTP) EXISTING 3'-0" X l' -O" STOREFRONT DOOR TO REMAIN; G.G. TO ENSURE ALL REQUIRED ENTRY/E6RE55 HARDWARE 15 PROVIDED AND IN WORKING CII 11►. 11► 11► 11► 11►Ak L---------- t_—_ -- -- D LINE OF ALUMINUM SUNSHADE (ABOVE). LINE OF IMPLIED CIRCULATION PATH THROUGH SHOWROOM ROUTE NEW UNDER SLAB POWER, DATA AND TELEPHONE TO NEAREST COLUMN OR HARD WALL bq'-4 1/2" 42'-6" 851-4" PROVIDE NEW 4" BLACK/BROWN ROPPE RUBBER BASE THROUGHOUT SHOWROOM AREA (TYP.) G.G. TO PAINT ELECTRICAL OUTLETS TO MATCH ADJACENT WALL SURFACE (TYP). NEW EXTERIOR ILLUMINATED SIGN, G.G. TO PROVIDE ELECTRICAL. (TYP.) 42-6" V-21/2" 1 6-0" NOTE AT EXISTING LEAVE -OUTS INFILL EXISTING LEAVE -OUTS WITH NEW 5" THICK (3000 PSI) GONGRETE OVER 10 MIL "STEGO" VAPOR BARRIER TO MATCH EXISTING AND COMPACTED SUBGRADE. REINFORCE WITH #4 BARS @ 15" O.G.E.W. DRILL 4 EPDXY #4 x 30" LONG DOWEL BARS INTO EXISTING SLAB ® 18" D.G. NEW ELECTRICAL PANEL 5HONROOM 101 I ' NEW FLOOR MOUNTED MOP SINK (RE: MEP); G.G. TO PROVIDE FRP-I TO 4S" AFF LON EAGH SIDE OF MOP SINK F I LES/ $REGOFIL75 E051 MEN .",,, C KI i03 C/'i HALL 102 �?_) 02 -1 (®JEI FIELD VERIFY FIELD VERIFY FIELD VERIFY TOP OF STEEL TDP OF STEEL TOP OF STEEL t 19 -4" A.F.F. t 18 -4" A.F.F. _t 17'-4" A.F.F. FIELD VERIFY FIELD VERIFY FIELD VERIFY BOTTOM OF STEEL BOTTOM OF STEEL BOTTOM OF STEEL t 17"-4" A.F.F. f 16'-4" A.F.F. t 15'-4" A.F.F. N Q G.G. TO ENSURE: 5% RUNNING SLOPE MAX,2% GROSS SLOPE MAX, 1/2" ELEVATION CHANGE MAX ATLANDING (TYP) EXISTING PAIR OF 3'-0" X 7'-0" DOORS TO REMAIN; G.G. TO ENSURE ALL REQUIRED ENTRY/EGRE55 HARDWARE IS PROVIDED AND IN WORKING ORDER. —NOMEN 104 NEW ADA COMPLIANT HI/LO E.D.F. AREA CALCULATIONS ROOM NO, ROOM NAME AREA NAME; AREA (50UARE FEET) 101 SHOWROOM SHOWROOM +/- 3,444 sq. ft. 102 HALL SERVICE +/- 61q SC[. ft. 103 MEN 104 WOMEN 105 FILE5/REGORD5 106 VALUE CENTER VALUE CENTER +/- l8 5q. ft. TOTAL:L.- I +/- 4,221 sq,. ft. FLOOR PLAN I/8:: = I: -O: NORTH Revisions ■ No. Date Description ■ AO -122.2005 LL GOMMENT5' ■ ■ THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECT: Intedur Tenant Improvements for: Mattress Firm Seminole Town Center 695 Town Center lioufevarc) Sanf oro, I'foriba 3277 THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITFIOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT, REPRODUCTION IS PROHIBITF0. COPYRIGHT 2008 LARRY L. CHRISTIAN A.I.A. ■ ■ ■ ■ ® ■ ■ ■ 4-1 C, ® ■ ■ ■ Lary L,, 0 • ristian A6I4A* � 1 3801 Kirby Dr., Suite 600' Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 Expires: 02.28.09 Larry L. Christian, A.I.A. Florida Architectural Registration #AR -0010755 FLOOR PLAN A-1 Date: 07.28.2008 ■ w Project No. 0805-776 ■ ■ 6RAPHIGS SGHEDULE ITEM # DE5GRIPTION QUANTITY ORDERED SR -001 OUR FIRM GUARANTEE, VINYL AG -I 5R-002 GUARANTEE 516N5 (SET OF 4) 12" X 12" 5R-003 STORE HOURS GONTAGT: 5R-004 SEALY MF DOOR LOGO (SET OF 2) KATHY LAPINE 5R-005GREAT _ NICHT 5 SLEEP LOGATION: SR -006 COMFORT HEADBOARD SIGNS SET OF 3) VALUE CENTER 5R-007 CENTER TOWER GRAPHIG5 5ERIE5, 5R-008 MF LOCO - MF TOWER SOFFIT #2qO ATLANT15 (BLUE) 5R-0061 (aj LIFESTYLE PHOTOGRAPHS (FRAMED) 6AUOE: SR -0061 (bj LIFESTYLE PHOTOGRAPHS FRAMED HJ HEBER 5R-OO�i (cj_ LIFESTYLE PHOTOGRAPHS FRAMEDj* PAINT 5R-OOq (d) LIFESTYLE PHOTOORAPHS FRAMED) " MANUFACTURER: 5R-0061 rj LIFESTYLE PHOTOGRAPHS (FRAMED) COLOR: 5R-OOq W LIFESTYLE PHOTOGRAPHS (FRAMED) FINISH: 5R-010 (a) COMPETITIVE AD BOX LEFT LOCATION, 5R-010 (EF COMPETITIVE AD BOX (RIGHT) 1/8" GB -80 FAWN - 4" 5R -OIL a HEADBOARD-- RED CARPET DELIVERY OA IOE: 5R-011 HEADBOARD - 5AT15FAGTION GUARANTEED MANUFACTURER: 5R-OII (c)� HEADBOARD - LOH PRICE COLOR: 5R-013 a 51MMON5 LOGO WINDOW FINISH: 5R-013 SEALY P05TURPEDIG WINDOW LOGO LOCATION: 5R-013 (G TEMPURPEDIG WINDOW LOGO JOHNSONITE SR -013 (dam 5TEARN5 AND F05TER WINDOW LOGO MANUFACTURER. 5R-014 5TEARN5 AND FOSTER HINDON SOFFIT SIGN COLOR, 5R-015 SEALY P05TURPEDIG SOFFIT 51CN FIN15H: 5R-016 MF LOGO SOFFIT 516N LOCATION: 5R-022 TEMPURPEDIG SOFFIT 51ON MANUFACTURER, 5R-023 51MMON5 SOFFIT SION COLOR: 5R-017 OUR PLEDGE FRAMED) -- FINISH: 5R-020 BEDDING AGGE55ORIE5 CENTER TOWER, BACK) LOGATION, 5R-025 (a) BACK DOOR COLOR LOGO - 30" MANUFACTURER: 5R-025 (b) BACK DOOR COLOR LOCO - 48" COLOR: 5R-MI5G HARDHARE FINISH: SATIN CONTACT: LOCATION: OVERALL WALLS, SOFFIT UNDER51DE NOTE : 6HAN6E ORDER REFLECT5 IN5TALLATION DATE NOTE: CONTRACTOR TO PROVIDE ADDITIONAL 5TOGK OF FIN15H MATERIALS AT COMPLETION OF WORK. ITEM5 PROVIDED TO TENANT INCLUDE: -GEILIN6 TILE -PAINT (ALL 6OLOR5) -LIGHT FIXTURE REPLAGMENT5 BUL155 -FLOOR FIN15HE5 (ALL) PLACE ALL ADDITIONAL 5TOGK IN AVAILABLE 5TORAGE AREA. VINYL COMPOST10N TILE ROOM No. VGT-I MANUFACTURER: AGOU5TIGAL SERIES: ESSENTIALS AG -I MANUFACTURER: ARM5TRON6 12" X 12" SERIES: O -DIREGT10NAL GONTAGT: EDOE: SQUARE LAY -IN - KATHY LAPINE GRI P. 15/16" LOGATION: ITEM NO.: 1450 (5 YR. NARRANTY) VALUE CENTER COLOR: WHITE (WH) 5ERIE5, TEXTURE: MEDIUM #2qO ATLANT15 (BLUE) LOCATION: 5HOHROOM 4 ALL AREAS (RE: RCP) 6AUOE: GONTRACTOR FURNISH AND INSTALL GONTAGT: HJ HEBER KATHY LAPINE PAINT 216.351.1200 P-1 MANUFACTURER: IGI DULUX PAINT COLOR: t"11q PILLAR (WHITE) VINYL BASE FINISH: E605HELL JOHN50NITE LOCATION, HEADBOARD MOLDING (MILLWORK ITEMj, PRODUCT NO: 1/8" GB -80 FAWN - 4" GEILINC TILE 4 GRID (51TE 5PEGIFIG) #80 FAWN OA IOE: EXPOSED 6EILIN6(51TE 5PEGIFIG) P-2 MANUFACTURER: IGI DULUX PAINT JOHN50NITE COLOR: #644 HINTER HHEAT (YELLGk4_ LOCATION: FINISH: SATIN _ _ — LOCATION: ACCENT HALL (REAR) 'v -2 MANUFACTURER: JOHNSONITE PRODUCT: P-3 MANUFACTURER. IGI DULUX PAINT COLOR: COLOR, #168 5GENIG ROSE (BURG)NDY) 1/8" FIN15H: SATIN GONTAGT: LOCATION: ACCENT WALL (RIGHT OF ENTRY) P-4 MANUFACTURER, IGI DULUX PAINT CONTRACTOR FURNISH AND INSTALL COLOR: #1334 STORMY SEAS (BLUE) FINISH: SATIN RB -I MANUFACTURER: LOGATION, ACCENT HALL LEFT OF ENTRY) P-5 MANUFACTURER: IGI DULUX PAINT DOLOR, COLOR: #2003 GIELO BLANCO (OFF-WHITE 1/8" FINISH: SATIN CONTACT: LOCATION: OVERALL WALLS, SOFFIT UNDER51DE 800.53 A527 (PHONE) RE5TROOM GEILINC.(IF CHB), _ 5HOWROOM AREA RE5TROOM HALLS ABOVE 51", STOCKROOM, CLEARANCE HAL1-5 P-6 MANUFACTURER: IGI DULUX PAINT DAL TILE COLOR: - #1250 RE5TLE55 SEA COLOR: FINISH: SATIN 12" X 12" LOCATION: CENTER TOWER SOFFIT (MILLWORK ITEM) P-7 MANUFACTURER, IGI DULUX PAINT 216.661.67615 COLOR: #5q8 OREAT DESERT (TAN) FINISH: SATIN LOGATION, BASEBOARDS PRODUCT: VILA VALLETA (REV. 12.13,2007) COLOR, P-8 MANUFACTURER: IGI DULUX PAINT GONTAGT, COLOR: #170 SKY ROCKET RED (BRIGHT RED) 800.825.2325 FINISH: SATIN LOCATION: LOCATION, CLEARANCE CENTER LOW HALLS AND CONTRACTOR FURNI5H AND INSTALL SOFFIT HALL TU HT -I MANUFACTURER: P-10 MANUFACTURER: IGI DULUX PAINT COLOR: COLOR: #325 AUTUMN BLUSH 12" X 12" FINISH: SATIN LOCATION. COMFORT TEST AREA 5OFFT FACE 216.661.61615 CONTRACTOR FURNISH AND INSTALL 4 REST SPA HALLS 4 FURR-DOWN CONTRACTOR FURNISH AND INSTALL HT -2 MANUFACTURER: P -II MANUFACTURER: IGI DULUX PAINT COLOR: COLOR: #151 STONINOTON BEIGE (MP# 30YY 44/114) 3" X 12" (BULLNOSE) FINISH: SATIN LOCATION: SPECIALTY BEDDING - SLEEP Rx AREA 216b61.67015 CONTRACTOR FURNISH AND INSTALL TOILET ROOM HALLS CONTRACTOR FURNISH AND INSTALL C'ROQj WA FRP-I RING F MANUFACTURER: MARLITE (WWW.MARLITE.GOM) #17 MARBLE BEIGE PATTERN: 5MOOTH FINISH CONTRACTOR FURNISH AND INSTALL PRODUCT #: 5 100 COLOR: WHITE 6RAPHIGS AND ORAPHIG INSTALLATION COORDINATED THROUGH CONTACT: MARLITE CONTACT: SAM BUTERA 713.651.2051 800.377.1221 (PHONE) 330.343.72,16 (FAX) _EMPLOYEE AUL.C.V2TOHER 5FAIINC,' LOCATION: RESTROOM HALL5 ADJAGENT TO ALL MATTRE55 FIRM TENANT FURNISH AND INSTALL FIXTURES UP TO 48" A.F.F. MILLWORK FIXTURE5 PROVIDE HHITE PVC, TRIM MOLDING "M350" AT INSIDE CORNERS, "M360" AT CONTACT: OUTSIDE CORNERS, "M365" AT DIVISION5, AND "M370" AT EXP05ED ED &E5. TENANT FURNI5H - CONTRACTOR INSTALL PROVIDE "Mg61" OUTSIDE CORNER GUARD AT EXPOSED VERTICAL CORNERS. ADD P15PI-6r BOARD I DISPLAY BOARD - PROVIDE BLOCKING IN HALL A5 REaV. MOUNT BOT. OF DISPLAY AT 54" A.F.F. !2AEELI GONTAGT: MATTRE55 FIRM G -I MANUFAGTURER CASUAL CARPET PATTERN: ONE BLOCK TENANT TO PROVIDE: 22" TELE5GOPING LADDER 4 MEDIUM RACK RO EP GOLOR: GUN METAL 8468 LOCATION: CENTER 15LAND CONTACT: JERRY ARNOLD 214.-142.1745 214.742.7241 F PLA5TIG LAMINATE PL -I MANUFACTURER: FORMICA PRODUGT: ARTISAN _ PRODUCT NO, 5804-43 UNDERLAYMENT: C.ONTAGT GEMENT OVER 3/4" MDF CONTACT: FORMICA I.BOO.FORMIGA (1.800.367.6422) LOCATION, VALUE CENTER RAISED PLATFORM -LAMINATE FLOQRIRC, LF -I MANUFAGTURER, ALLOG - ORIGINAL PRODUCT: HINGHE5TER OAK PRODUCT NO: 4573 VINYL REDUGER, MERGER #,130 GOLOR: CHOCOLATE T -MOLD METAL TRACK: T -MOLD TRACK #q80 UNDERLAYMENT- _ MT6 MIL POLY FILM GONTAGT: JERRY ARNOLD 214.742.1745 214.742.7241 (FAX) LOCATION: RAGE TRACK TENANT FURNISH - CONTRACTOR IN5TALL NOTE: CONTRACTOR TO PROVIDE ADDITIONAL 5TOGK OF FIN15H MATERIALS AT COMPLETION OF WORK. ITEM5 PROVIDED TO TENANT INCLUDE: -GEILIN6 TILE -PAINT (ALL 6OLOR5) -LIGHT FIXTURE REPLAGMENT5 BUL155 -FLOOR FIN15HE5 (ALL) PLACE ALL ADDITIONAL 5TOGK IN AVAILABLE 5TORAGE AREA. VINYL COMPOST10N TILE ROOM No. VGT-I MANUFACTURER: _ MANNIN6TON SERIES: ESSENTIALS COLOR: 143 FLAX (TAUPE) 51ZE: 12" X 12" GAUGE: 1/8" GONTAGT: HJ HEBER - __ KATHY LAPINE WOMEN 21(a.351.1200 LOGATION: 106 CONTRACTOR FURNISH AND INSTALL VALUE CENTER VGT-2 MANUFAGTURER, MANNINOTON 5ERIE5, E55ENTIAL5 COLOR: #2qO ATLANT15 (BLUE) SIZE: 12" X 12" 6AUOE: 1/8" GONTAGT: HJ HEBER KATHY LAPINE 216.351.1200 LOCATION: CLEARANCE CENTER, 5TORA6E GONTRAGTOR FURNISH AND INSTALL VINYL BASE VB -1 MANUFACTURER: JOHN50NITE PRODUGT, VINYL HALL BASE PRODUCT NO: 1/8" GB -80 FAWN - 4" COLOR: #80 FAWN OA IOE: I/8" HEIGHT: 4" GONTAGT. JOHN50NITE 800.8gq.8gl6 LOCATION: CONTRACTOR FURNI5H AND INSTALL _ _ — 'v -2 MANUFACTURER: JOHNSONITE PRODUCT: VINYL WALL BASE PRODUCT NO: 1/8" G13-83 MIDNIGHT - 4" COLOR: #83 MIDNIGHT GAUGE: 1/8" HEIGHT: 4" GONTAGT: JOHN5ONI TE 800.mcf bq I6 LOGATION, CLEARANGE 5TORA6E CONTRACTOR FURNISH AND INSTALL RB -I MANUFACTURER: KOPPE PRODUCT: RUBBER HALL BASE PRODUCT NO: 1/8" 513R RUBBER - 4" DOLOR, #Iq3 BLACK -BROWN GAUGE: 1/8" HEIGHT: 4" CONTACT: ROPPE 800.53 A527 (PHONE) 41q.435.1056 (FAX) LOCATION: 5HOWROOM AREA CONTRACTOR FURNISH AND INSTALL TILE FT -I MANUFACTURER: DAL TILE PRODUGT: VILA VALLETA (REV. 12.13.2007) COLOR: VV05 RANDOM VARIATION SIZE: 12" X 12" CONTACT: CINDY GLECKNER 800.825.2325 216.661.67615 LOCATION, GENTER 5ERVIGE DESK AREA, TOILET ROOM FLOOR CONTRACTOR FURNISH AND INSTALL FT -2 MANUFACTURER: DAL TILE PRODUCT: VILA VALLETA (REV. 12.13,2007) COLOR, VVO5 (RANDOM VARIATION) SIZE: 6" X 6" GONTAGT, CINDY GLEGKNER 800.825.2325 2 6 661.6 g5 LOCATION: ENTRY AREA GONTRAGTOR FURNISH AND INSTALL HALL TU HT -I MANUFACTURER: DAL TILE PRODUGT, VILA VALLETA (REV. 12.13.2007) COLOR: V\/O5 (RANDOM VARIATION) 51ZE: 12" X 12" GONTAGT: GINDY GLEGKNER 800.825.2325 216.661.61615 LOCATION: TOLIET ROOM HALLS TO 48" A,F,F, CONTRACTOR FURNISH AND INSTALL HT -2 MANUFACTURER: DAL TILE PRODUCT: VILA VALLETA V. 12.13.20U-I-)— 2.13.2007COLOR: COLOR: VV05 (RANDOM VARIATION) SIZE: 3" X 12" (BULLNOSE) GONTAGT: CINDY GLEGKNER 800.825.2325 216b61.67015 LOCATION: TOILET ROOM HALLS CONTRACTOR FURNISH AND INSTALL C'ROQj 6-1 MANUFACTURER: LATIGRETE OR EQUAL PRODUCT: #17 MARBLE BEIGE COLOR: SANDED GROUT CONTRACTOR FURNISH AND INSTALL 6RAPHI G5 6RAPHIGS AND ORAPHIG INSTALLATION COORDINATED THROUGH MATTRESS FIRM CONTACT: SAM BUTERA 713.651.2051 TENANT FURNI5H AND INSTALL _EMPLOYEE AUL.C.V2TOHER 5FAIINC,' CONTACT: MATTRE55 FIRM TENANT FURNISH AND INSTALL MILLWORK FIXTURE5 M1ECNOkK-FFXTURE5­AND-MILLHORK CONTACT: MATTRESS FIRM TENANT FURNI5H - CONTRACTOR INSTALL ADD P15PI-6r BOARD I DISPLAY BOARD - PROVIDE BLOCKING IN HALL A5 REaV. MOUNT BOT. OF DISPLAY AT 54" A.F.F. _ GONTAGT: MATTRE55 FIRM TENANT FURNISH - CONTRACTOR IN5TALL A� DD1=R F TENANT TO PROVIDE: 22" TELE5GOPING LADDER 4 MEDIUM RACK RO EP FINISH SCHEDULE N.T.5. 11 mm TOP OF STEEL f 19'-4" A.F.F. BOTTOM OF STEEL f 17'-4' A.F.F. RETAIL. BED COUNT -- 41 NET USABLE SHOWROOM AREA: +/- 41046 S.F. FIXTURE ALAN AREA 0ALCULATION5 ROOM No. ROOM NAME AREA NAME AREA (50UARE IF-EET) 101 SHOWROOM 5HOWROOM +/- 3,444 sq,. ft. 102 HALL 5ERVIGE +/- 61a sq,. ft. 103 MEN 104 WOMEN 105 FILE5/REGORD5 106 VALUE GENTER VALUE CENTER +/- 78 sq,. ft. TOTAL- +/- 4,221 sq,. ft. 1/8" = 11-0"La I NORTH m ■ Revisions m IM No. Date Description 1AA 0122.2008 LL GONWNT5 THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECT: Interior Tenant Improvements for: Mattress Firm Seminole Town Center 695 Town Center Boulevaro San f oro1 Plorioa 32771 THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL, AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBITED, COPYRIGHT 2oo8 LA:1AY L. CHRISTIANS A.I.A. 0 0 ® I w __1 LaTTNL. c ristian A.I.A. 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 0 - Ct s Expires: 02.26.09 Larry L. Christian, A.I.A. Florida Architectural Registration p #AR -0010755 I. ® m FIXTURE PLAN I i A-2- Date: 07.28.2008 Project No. 0805-776 I Pq 0 . d L H 0 ® I w __1 LaTTNL. c ristian A.I.A. 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 0 - Ct s Expires: 02.26.09 Larry L. Christian, A.I.A. Florida Architectural Registration p #AR -0010755 I. ® m FIXTURE PLAN I i A-2- Date: 07.28.2008 Project No. 0805-776 I NOTE: APPROX. NEI6HT: 120 Ibg. PER FIXTURES INTERNATIONAL FASTEN UNI-5TRUT TO TOP CHORD OF EXISTING BAR .JOISTS (TYPICAL.) 3/16" GRADE 30 STEEL CHAIN, MIN. -150 LBS. NORK LOAD LIMIT, FASTENED TO UNI -STRUT AND EYE BOLT 516NACvE HEADER VALANCE (BY OWNER) TOP OF VALANCE - MOUNT FLUSH WITH GEILIN6 5'- 4 LAMP FLUORESCENT LIGHT FIXTURE. MOUNT FIXTURE TIGHT TO UNDERSIDE OF GEILIN6 4 BACK SIDE OF FIXTURE AS INDICATED. INSTALL FIXTURE AT FRONT SIDE OF VALANCE ONLY. 1/4-20 1" DIA. EYE -BOLT (PROVIDED BY MILLNORK MANUFACTURER) SIGNAGE VALANCE .MOUNTING DETAIL N.T.5. TYPE DESCRIPTION LAMPS NOTES LEGEND A 2'x4', 3 -LAMP KGE55ED ACRYLIC, LENS TROFFER, GENERAL GE LI6HTIN6 NAEP: 25612 FURNI5HED BY 102 HALL GRAPE, (1) MULTI -VOLT ELEGTRONIG BALLAST, GRID TYPE, F32T8/5PX35/EG0 TENANT, INSTALLED Q 104 COOPER: 2688-332A-UNV-EBSI-EM-U; MVOLT V3 6EBI015; WITH INITIAL LUMENS: 2850 GRI: 85 BY 6.G. lob VALUE CENTER EMERGENCY BATTERY PACK KELVIN TEMP: 3500 TOTAL: B 64 -LAMP GENERAL FURP05E CHANNEL 5LIMLINE STRIP FIXTURE, 6E LIGHTING NAEP: 25612 FURNISHED BY E.5. BALLAST; LITHONIA: T6-232 MULTI -VOLT G.E.B. F52T8/5PX35/EGO TENANT, INSTALLED INITIAL LUMENS: 2g50 GRI: 85 BY G.G. INSIpE CU5TOMER KELVIN TEMP: 3500 5ERVIGE VALANCE G DMF LIGHTING - RECESSED 4" LOH-VOLTAGE FIXTURE; IG AIR GE LIGHTING CONSTANT COLOR - PREGI5E FURNISHED BY TIGHT, ENERGY EFFIGENT, SEALED DOUBLE HALL HOUSING; PROPUGT #:20833 (MR -16, 2 -PIN 6X5.3) TENANT, INSTALLED PRE -WIRED UL LISTED . UW -,TION BOX, 22 GUAGE PIE -FORMED 050MRI6/G/FL40 BY 6.C,. c= FRAME, 120 V TO 12V, 50VA TRANSFORMER (OPTIONAL 2TIV); VOLTS: 12, HATT5: 50, LIFESPAN: 6000 HRS. HOU51N6 MODEL: # PH441GAT, TRIM MODEL: 4124415H (HHITE); KELVIN TEMP: 3050 D 4'2 -LAMP GENERAL PURPOSE CHANNEL 5LIMLINE STRIP FIXTURE, 6E LI6HTIN6 NAEP: 25612 FURNISHED BY E.5. BALLA5T; LITHONIA: G 2 32 MULTI -VOLT 6.EB. F32T8/5PX35/EGO TENANT, INSTALLED VALUr- GENS INITIAL LUMENS: 2g50 GRI: 85 BY G.G. Lf� KELVIN TEMP: 3500 GLEARANGE GENrER E q" OPEN RECESSED DOHNLIGHT HITH CLEAR 5PEGULAR LOH GE LI6HTING NAEP: 46314 FURNISHED BY (NOT IRIDESCENT REFLECTOR MVOLT. THO 42H TRIPLE -TUBE LAMPS. F42TBX/5PX35/A/4P/EOL TENANT, INSTALLED O USED) DMF LIOHTIN6: PHFHq-242E/Dg06. EMT TO BE USED FOR HANGER INITIAL LUMENS: 3200 GRI: 82 BY G.G. BARS, SUPPLIED BY E.G. KELVIN TEMP: 3500 F 6 VOLT THIN -HEAD BATTERY LIGHT, SURFACE MOUNTED. LITHONIA: INCLUDED FWN15HED BY (NOT ELM2-120V TENANT, INSTALLED USED) BY G.G. 6 6REENHEGK EXHAUST FAN, MODEL #5P-AI10;15 GFM, H/ 6RAVITY RE: MEP FURNISHED BY POHNDRAFT DAMPER, HALL SHITCH, 4 DI5GONNEGT 6.6. T HAG LIGHTING - H STYLE TRACK HITH LIVE END CONNECTOR AND 05RAM 5YLVANIA: PART # 55125 FURNISHED BY ARIII: 12 VOLT HEAD (HHITE); TRACK MODELS HT2-HT, HT4-HT, HT6-HT, ARIII/FL25 12 VOLT; HATTA6,E PER ELEC. G.G. HTS -HT (RE: RGP FOR REWIRED LEN6HT5). LIVE END CONNECTOR 3000 HOUR AVERAGE RATED LIFE v o 0 0 0 MODEL NUMBER: HLE-HT. G.G. TO PROVIDE NUMBER OF HEADS 653 SOCKET TYPE; UP TO 50,000 GBGP (HHT-g36L-HT), AS 5WHN ON R.G.P. 4 ELECTRICAL DRAHING5. X 61-6. MOUNTED LED. EXIT 516N H/ POLYGARBONATE HOUSING, RED L.E.D. FURNISHED BY LETTERS, BATTERY BAGK-UP. LITHONIA: LOM 5 H 3 R 120/2-11 ELN I I OMER NOTES 6.6. RESPONSIBLE FOR PROVIDING LIGHTING VENDOR GOUNT5 BY TYPE REOUIRED TO PERFORM ALL HORK AGGORDING TO PLANS LIGHTING VENDOR: AMERICAN LIGHT, "I STEADMONT, HOUSTON, TEXAS T1040 GONTAGT5. ALLYN 005TICK, MIKE FONT, STEVE BROHN PHONE:800-880-1401 FAX: 113-4(92-62&2 LIGHT FIXTUIRE SCHEDULE N.T.S. Im 02 TOP OF STEEL i 19'-4p A.F.F. BOTTOM OF STEEL t17'-4" A.FF. 19 OI 0 2x4 LAY -IN A, 12'-0" A.F.F. 0 153 2x4 FLUORES( FIXTURES (TYF NEW ILLUMINAI PROVIDE ELE( 51 GNAGE LOG, REQUIREMENT`_ COMPANY (TYI NEW EMERGEN (TYP) RE: 'X' C NEW DUPLEX C UNDERSIDE OF APPROX. 12'-C MULLIONS. PA SURFACES TO COLOR (TYP). LINE OF EXIST TOP OF STEEL ITOPI OF STEEL f 19'-4" A.F.F. i 18'-4y A.F.F BOTTOM OF STEEL t 17"-4" A.F.F. BOTTOM OF STEEL t 16'-4" A.FF. 2x4 LAY -IN AGOU5TIC CEILING ® 12'-0" A.F.F. (AG -I) — 2x4 FLUORESCENT LAY -IN LIGHT FIXTURES (RE: 'A' 02/A3) — EXHAUST FAN (RE: "G" 02/A-3) (TYP. OF 2 RESTROOM5) — 2x4 FLUORESCENT LAY -IN LIGHT FIXTURES @ q' -O" A.F.F. (TTP OF 2 RE5TROOM5) (RE: 'A' 02/A3) — 2x4 LAY -IN AGOU5TIG GEILIN6 ® 10'-0" A.F.F. (AC -I) — NEN EMERGENCY EXIT LIGHT (TYP) RE: 'X' 02/A3 TOP OF STEEL f 17'-4' A.F.F. IBOTTOM OF STEEL t 15'-4" A.F.F. ARr=A CALCULATION ROOM NO. ROOM NAME AREA NAME AREA (SQUARE FEET) 101 5HONROOM SHOWROOM +/- 3,444 ScL. ft. 102 HALL SERVICE +/- 694 scL, ft. 103 MEN 104 WOMEN 105 FILES/RECORDS lob VALUE CENTER VALUE CENTER +/-75 5cL. ft. TOTAL: +/- 4,221 15 1. ft. AETLECTED CEILING PLAN -0': Revisions ® �1 No. Date Description e IAOIM.2008 L. COMMENT5 TH1 SE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY 1OR THE IOLLOWINC PROJECT: Iviterior't'enant lmprovemerits for: Mattress 1,irm Semim(c 'Torun Center 695 i'mm Center Boa(evarb Sari f or0j .Pforiba 32.771 THEY ARE NOT SUITABLE POR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OL THE ARCHITECT. REPRODUCTION 1S PROHIBITED, COPYRIGHT 2oo8 LARRY L. CHRISTIANS A.I.A. ® 0 IJ LaTTN L. Christian A.I.A. E 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 "T2809 .T2809 Expires: 02.28.09 Larry L. Christian, A.I.A. Florida Architectural Registration BAR -0010755 m OBLINO PLAN I NORTH Date: 07.28.2008 ®I Project No. 0805--776 I; a �I 4 -mJ w Lf� f� ® 0 IJ LaTTN L. Christian A.I.A. E 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 "T2809 .T2809 Expires: 02.28.09 Larry L. Christian, A.I.A. Florida Architectural Registration BAR -0010755 m OBLINO PLAN I NORTH Date: 07.28.2008 ®I Project No. 0805--776 I; a 0 Notes: I. WALLS AT FRONT ENTRY WILL BE PAINTED P-5 2. THE MMBOARP DETAIL ONLY OCCURS ON THE BOTH SIDES OF THE 5HOWROOM. THE TRIMBOARD DOES NOT OCCUR AT THE FRONT OR REAR WALLS. 5, - LOCATE FACE TRIMBOARD 10'-0" FOR A 14'-0" GLC, - LOCATE PAGE TRIMBOARD 9'-0" FOR A 12'-0" GLC, - LOCATE PAGE TRIMBOARD V -O" FOR A 10'-0" GLC. 4. TRIMBOARD SHALL BE PAINTED THE SAME COLOR AS THE ADJACENT ACCENT WALL (P-5) I X 4 (NOM) PAGE TRIMBOARP (PAINT P-5) SECTION @ TRIMBOARD 1" = 1'-0" NOTE: G.G. TO PROVIDE SMOOTH TEXTURE PAINT FIN15H AT INTERIOR 6RAPHIGS DISPLAY AREAS (WHERE APPLIGIBLE) (RE: FLOOR PLAN AND INTERIOR ELEVATIONS FOR PAINT COLOR LOGATION5) - WALLS ABOVE TRIM -BOARD - (P-5 4 P-4) SOFFIT ABOVE STOREFRONT (AT ENTRY) - (P-10) FURR DOWN AT VALUE CENTER - (P-2) FURR DOWN ABOVE CLEARANCE CENTER - (P -S) NEW COLUMN FURR-OUT PAINT PER WALL ASSIGNMENT I X 2 (NOM.) FACE TRIMBOARD (PAINT P-5) � m NEW COLUMN PURR -OUT (PAINT P-5) TYPICAL COLUMN DETAIL I" = 1'-0" NEW 2X4 LAY -IN A6OU5TI6 CEILING (AG -I) TO BE INSTALLED AT 10'-0" A.F.F. L NEW 3'-0" x 7'_011 HL. GORE M. DOOR(S) W/ LEVER HARDWARE, LOOK, CLOSER, 4 KIGKPLATE; UNDERGUTED BOTTOM OF DOOR I" (TYP OF 2 RE5TROOMS) o6 INTERIOR ELEVATION — E.D.F v4" = r -o" 4 WINDOW 51ZES VARY: LARCE5T LOWER WINDOW 51ZE 15 +/- 42" WIDE SMALLEST LOWER WINDOW 51ZE 15 +/- 41" WIDE LOWEST HORIZONTAL MULLION AT 51" A.F.F. 11 NEW 2X4 LAY -IN AGOU5TIG GEILING (AG -I) TO BE INSTALLED AT 12'-0" A.E.E. NEIN 2X4 LAY -IN AGOU5TIG GEILING (AG -1) TO BE INSTALLED AT 12'-0" A.P.F. � P-5 P-10 EX b 5TIN65 5TOREE LAZIN6 TO RE NT IN SHOWROOM 104 z rz- EXI A G TING 5TOREl AZING TO NT IN v 4 E d I TING 5TOnF LAZING TO RE N' T AIN 105 FFRONTP-10 OAIN z � z P-5 P-5 oY a� �m 1 L NEW 3'-0" x 7'_011 HL. GORE M. DOOR(S) W/ LEVER HARDWARE, LOOK, CLOSER, 4 KIGKPLATE; UNDERGUTED BOTTOM OF DOOR I" (TYP OF 2 RE5TROOMS) o6 INTERIOR ELEVATION — E.D.F v4" = r -o" 4 WINDOW 51ZES VARY: LARCE5T LOWER WINDOW 51ZE 15 +/- 42" WIDE SMALLEST LOWER WINDOW 51ZE 15 +/- 41" WIDE LOWEST HORIZONTAL MULLION AT 51" A.F.F. 11 NEW 2X4 LAY -IN AGOU5TIG GEILING (AG -I) TO BE INSTALLED AT 12'-0" A.E.E. NEIN 2X4 LAY -IN AGOU5TIG GEILING (AG -1) TO BE INSTALLED AT 12'-0" A.P.F. 4" BLACK ROPPE (TYP. SHOWROOM) -I 4" BLACK ROPPE -I (TYP.5HOWROOM) INTERIOR ELEVATION — SHOWROOM 1/411 ! 11-011 1r P-5 TRI MBOAP (RE: OS/A-4) P`5 (TYP.) 4" BLACK KOPPE (TYP. SHOWROOM) NEW 2X4 LAY -IN ACOUSTIC GEILING (AG -I) TO BE IN5TALLED AT 12'-0" A.F.F. P-3 NEW 2X4 LAY -IN ACOUSTIC GEILING (AG -I) TO BE INSTALLED AT 12'-0" A.F.F. � P-5 P-10 EX b 5TIN65 5TOREE LAZIN6 TO RE NT IN SHOWROOM 104 OP rz- EXI A G TING 5TOREl AZING TO NT IN v 4 E d I TING 5TOnF LAZING TO RE N' T AIN EX15TI G d G1.AZIN 100 FFRONTP-10 OAIN z � z P-5 P-5 4" BLACK ROPPE (TYP. SHOWROOM) -I 4" BLACK ROPPE -I (TYP.5HOWROOM) INTERIOR ELEVATION — SHOWROOM 1/411 ! 11-011 1r P-5 TRI MBOAP (RE: OS/A-4) P`5 (TYP.) 4" BLACK KOPPE (TYP. SHOWROOM) NEW 2X4 LAY -IN ACOUSTIC GEILING (AG -I) TO BE IN5TALLED AT 12'-0" A.F.F. P-3 NEW 2X4 LAY -IN ACOUSTIC GEILING (AG -I) TO BE INSTALLED AT 12'-0" A.F.F. P-5 SHOWROOM EX TING 5TOREFRTNT 4 AZING TO IN ---� P-5 P -y5 _7 4" BLACK KOPPE -I (TYP.5HOWROOM) INTEXIOB, ELEVATION — SHOWROOM 1/4" =1'-0" 4 NEW 2X4 LAY -IN ACOUSTIC i CEILING (AG -I) TO BE INSTALLED AT A.F.F. p L03 NEW 2X4 LAY -IN ACOUSTIC GEILING (AG -I) TO BE INSTALLED AT 12'-0" A.F.F. � P-5 EX b 5TIN65 5TOREE LAZIN6 TO RE NT IN cV 104 P-5 SHOWROOM EX TING 5TOREFRTNT 4 AZING TO IN ---� P-5 P -y5 _7 4" BLACK KOPPE -I (TYP.5HOWROOM) INTEXIOB, ELEVATION — SHOWROOM 1/4" =1'-0" 4 NEW 2X4 LAY -IN ACOUSTIC i CEILING (AG -I) TO BE INSTALLED AT A.F.F. p L03 NEW 2X4 LAY -IN ACOUSTIC GEILING (AG -I) TO BE INSTALLED AT 12'-0" A.F.F. 4" BLACK ROPPE (TYP. SHOWROOM) 4" BLACK ROPPE RB -I (TYP. SHOWROOM) INTERIOR ELEVATION — SHOWROOM 1/411 = 11-011 NEW 2X4 LAY -IN ACOUSTIC CEILING (AG -I) TO BE INSTALLED AT 10'-0" A.F.F, A,--IE55113LE 516NAGE (TYP) z u, vNL � P-5 VALUE CENTERP-2 5HOWROOM P-3 5HOWROOM cV 104 OP 0!03j v 4 a P-5 P-5 P`5 z � z P-5 P-5 oY a� �m 1 C/5 L /'1 Q OPEN U H \ X X X X X X X X X X X X X t�y t�� tc��-- cc��-' ��'' X ��'- Q' c�X- cc�X�-- X' XF' ��X'' n �eF- X X X � Cf) !1) (1) !1> (1) (i> !() tt) 11) , w "' iFFC� ) Z c�}X-- t) rycX�-- ") c�X' Z 71 4" BLACK ROPPE (TYP. SHOWROOM) 4" BLACK ROPPE RB -I (TYP. SHOWROOM) INTERIOR ELEVATION — SHOWROOM 1/411 = 11-011 NEW 2X4 LAY -IN ACOUSTIC CEILING (AG -I) TO BE INSTALLED AT 10'-0" A.F.F, A,--IE55113LE 516NAGE (TYP) z u, vNL � P-5 HALL P-5 5HOWROOM P-3 104 OP 0!03j v 4 a P-5 P-5 P`5 VB -I 4" VINYL BASEBOARD (TYP.) NEW 5'-0" x 71'-0" HL. GORE WD. DOOR(5) W/ LEVER HARDWARE, LOCK, CLOSER, 4 KIGKPLATE; UNDERGUTED BOTTOM OF DOOR I" (TYP OF 2 RE5TRDOMS) INTERIOR ELEVATION — HALL 1/411= 11-011 05 4 TRIMBOARD (RE:OS/A-4) P`5 (TYP.) NEW 2X4 LAY -IN ACOUSTIC CEILING (AG -I) TO BE INSTALLED AT 12'-0" A.F.F. m N 5HOWROOM P-3 4 v a P-5 P-5 P`5 4" BLACK ROPPE (TYP. SHOWROOM) INTERIOR ELEVATION — SHOWROOM 1/411 I,-ol1 F=7 I� Revisions !U No. Date Description QOi.22.2005 LL GOWIEW5 I THESE DOCUMENTS HAVE BEEN PIUTAUR) SPECIFICALLY 101 'T IE FOLLOWING PROJECT: Interior Tenant Ivnprovenments for: Mattress Firm Seminole Town Center 695 Town Center Boulevarb Sanf orO, P4ori6a 39771 'THEY ARE NOT SUITABLE .1011 USE ON OT11P,R PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARC1111ECf. REPRODUCTION IS PROHIBITED, COPYXIGHT 2oo8 I,AlZ[ZY L. CHRISTIANS A.I.A. Lary ristian AOIOA@ 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 Expires: 02.28.09 Larry I,. Christian, A.I.A. Florida Architectural Registration #AR -0010755 INTERIOR ELEVATIONSI A-4 Date: 07.28.2008 f III �g Project No. 0805-776 a: i 4 C/5 L /'1 H Lary ristian AOIOA@ 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 Expires: 02.28.09 Larry I,. Christian, A.I.A. Florida Architectural Registration #AR -0010755 INTERIOR ELEVATIONSI A-4 Date: 07.28.2008 f III �g Project No. 0805-776 a: i 4 CARPET EQ. EDGE OF1 FLOOR TILE I I i 14B/A5 3" WIRE GROMMETS II-II/161, II-II/16' (TYP) 14A/ 2-213/169' 111-0' .PLAN I'-2 7/8' 2-213/16" I Eo N m ELEVATION - A q' -II 1/2" ELEVATION -r B CUSTOMER SERVICE DESK 1 14 EXISTING REINFORCED CONCRETE SLAB SAWGUT CONCRETE SLAB MIN. 1 1/2" DEEP, BREAK OUT CONCRETE LEAVING EXISTING REBAR AND VAPOR BARRIER INTACT. GUT EXISTING REBAR AND VAPOR BARRIER ALONG THE CENTER OF THE TRENCH. BEND REBAR AND UP TO EXPOSE WORK AREA. SPLICE #3 BARS TO EXISTING RE -BAR, ADD #3 BARS LONGITUDINALLY @ 16" O.G. PROVIDE A VAPOR BARRIER EaUIV. TO 10 MIL. 'STEGOWRAP' BELOW NEW CONCRETE - TAPE NEW VAPOR BARRIER TO EXISTING 3000 P51 CONCRETE INFILL, MATCH EXISTING ADJIAGENT FINISH I SAW CUT DTL, GEMENT STABILIZED SAND NEW PIPING OR CONDUIT N.T. s. 12 qOT USED N T Accessibjfjt Notes: I, MAXIMUM THRESHOLD HEIGHT SHALL BE 1/2" WITH A BEVELED SLOPE NO GREATER THAN 1:2, cf. IN GENERAL, ANY CONTROL MECHANISM REQUIRING USE BY BUILDING 0CGUPANT5 SHALL BE MOUNTED AT 45" A.F.F. MAXIMUM TO 2. OPERATING DEVICES ON ACCESSIBLE DOORS SHALL BE NO HIGHER THE HIGHEST OPERABLE PART OF OBJECT. THE MINIMUM MOUNTING THAN 46" A.F.F. HEIGHT OF ANY CONTROL MECHANISM SHALL BE 15" A.F.F TO THE LOWEST OPERABLE PART OF OBJECT, UNLESS NOTED OTHERWISE. 3. DOOR GLOSERS SHALL BE A TYPE LABELED FOR ACCF-551BILITY TYPICAL ITEMS INCLUDE BUT NOT LIMITED TO ARE: ELECT. AND BE ABLE TO BE ADJUSTED FOR A SWEEP PERIOD 5UGH THAT FROM SWITCHES, TELEPHONE5/TDD'S, THERMOSTATS, ELECT OUTLETS, AN OPEN POSITION OF 10 DEGREES, THE DOOR WILL TAKE AT LEAST DATA TERMINALS, ALARM PULL -STATIONS, DooR BUZZERS, THREE (3) SECONDS MOVE TO AN OPEN POSITION OF APPROXIMATELY 12 DEGREES, lo. GRAB BARS IN RE5TROOMS MUST BE 1-1/4" To 1-1/2" O.D. AND MUST BE INSTALLED To WITHSTAND A LOAD OF 250 LB5 AS DESIGNED. L��USED 4. DOOR CLOSERS SHOULD BE ADJUSTABLE 50 THAT THE OPENING FORGE REQUIRED TO PUSH OR PULL A DOOR OPEN IS 8.5 LBS. 11. ALL EXPOSED DRAIN PIPES AND HOT WATER SUPPLY LINES UNDER MAXIMUM FOR EXTERIOR HINGED DOORS AND 5 LBS, MAXIMUM FOR ACCESSIBLE LAVS/SINKS SHALL BE INSULATED TO PROTECT AGAINST INTERIOR DOORS. THE FORCE REQUIRED SHALL BE MEASURED AS CONTACT. THERE SHALL BE NO SHARP OR ABRA5IVE SURFACES UNDER APPLIED PERPENDICULAR TO THE DOOR AT THE OPENER OR 30 INCHES SINKS. FROM THE HINGED SIDE. 12, SIGNAGE AT DOORS AND OTHER AREAS REQUIRED TO BE 5. ALL DOORS REQUIRING "HAND TW15T" OPERATION SHALL BE ACCESSIBLE SHALL MEET THE FOLLOWING CRITERIA: PROVIDED A "LEVER TYPE" DOOR OPERATOR INSTEAD OF THE TRADITIONAL ROUND KNOB. A. COLOR 4 CONTRAST - CHARACTERS AND BACKGROUND SHALL HAVE A NON GLARE FINISH. CHARACTERS AND THEIR 6, IF ANY ITEM LISTED IN THE HARDWARE SCHEDULE IS NOT AN BACKGROUNDS SHALL HAVE COLORS CONTRASTING TO EACH ACCESSIBLE PRODUCT, IT IS THE RESPONSIBILITY OF THE OTHER. EITHER A DARK CHARACTER ON A LIGHT BACKGROUND OR GENERAL CONTRACTOR TO NOTIFY THE ARCHITECT OF 5UGH AND VICE VERSA, PROVIDE FOR THE ARGHITECT5 REVIEW, IN THE FORM OF SHOP DRAWING SUBMITTALS, AN EQUIVALENT ,hGGES5IBLE PRODUCT. IN B. CHARACTER PROPORTION 4 HEIGHT - LETTERS 4 NUMBERS ON THE EVENT THAT SHOP DRAWINGS ARE NOT SUBMITTED FOR FINISH SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 3:5 HARDWARE, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR I:I AND A STROKE WIDTH To HEIGHT RATIO BETWEEN 1:5 PROVIDING ACCESSIBLE HARDWARE, 1:10, 7. ACCESSIBLE PARKING AND ADJACENT ACCESS AISLES SHALL HAVE C. RAISED BRAILLE CHARACTERS PICTOGRAMS - LETTERS AND SMOOTH TEXTURE AND A MAX. SLOPE OF 2% IN ANY DIRECTIONS. NUMERALS, SHALL BE RAISED 1/32" MINIMUM. UPPERCASE, SIMPLE AGGESSIBLE ROUTES SHALL HAVE A MAX. SLOPE OF 5% IN TYPEFACE ACCOMPANIED WITH GRADE 2 BRAILLE RAISED DIRECTION OF TRAVEL AND 2% GROSS SLOPE. ALL ACCESSIBLE CHARACTERS SHALL BE BETWEEN 5/5" 4 2" IN HEIGHT. CURB RAMPS SHALL HAVE A MAX. SLOPE OF 8.55% (1:12) PICTOGRAMS, WHEN USED, SHALL HAVE A VERBAL DESCRIPTION DIRECTLY BELOW PICTOGRAM. PICTOGRAM BORDER SHALL BE 6" i3. ACCESSIBLE LAVATORY FAUCET CONTROLS SHALL BE LEVER WIDE MINIMUM. OPERATED. PUSH -TYPE OR ELECTRONICALLY ACTIVATED MUST NOT REQUIRE MORE THAN 5 LB OF FORGE TO OPERATE. ANY SELF-GL051N6 VALVES MUST REMAIN IN OPERATION AT LEAST 10 SECONDS, ACCESSIBILITY NOTES N.T.S. z3 �USED LOCATE 5167NA6E / ON STRIKE SIDE / OF DOOR l / \� 1 I 2' ADA COMPLIANT / LEVER TYPE TYPICAL ELEG. SWITCH I MOUNTING HEIGHT - DIMENSION TO CENTER OF DEVICE TYPICAL ELEG. RECEPTACLE MOUNTING HEIGHT - DIMENS1oN TO CENTER OF DEVICE (TYPICAL) HOLLOW GORE WOOD DOOR TO BE PAINTED WITH SEMI -GLOSS ENAMEL OF THE SAME COLOR AS THE WALL ON WHIGH THE DOOR 15 INSTALLED. (UNLESS OTHERWISE NOTED) VT'G. HT. STANDARDS 1/211 PROVIDE WHITE PVG TRIM MOLDING "M350" AT IN51DE CORNERS, "M360" AT OUTSIDE CORNERS, "M365" AT DIVISIONS, AND "M370" AT EXPOSED EDGES. PROVIDE "Mgbl" OUTSIDE CORNER GUARD AT E�;POSED VERTICAL CORNERS. m � cV 36" # 42" MINIMUM LENGTH (RE: 04/A-5) Q m STAINLESS STEEL CHANNEL FRAMED MIRROR 24"x36" STILE - B.O. REFLEGTI VE SURFACE 40" MAX. CARPET 2-213/16" I Eo N m ELEVATION - A q' -II 1/2" ELEVATION -r B CUSTOMER SERVICE DESK 1 14 EXISTING REINFORCED CONCRETE SLAB SAWGUT CONCRETE SLAB MIN. 1 1/2" DEEP, BREAK OUT CONCRETE LEAVING EXISTING REBAR AND VAPOR BARRIER INTACT. GUT EXISTING REBAR AND VAPOR BARRIER ALONG THE CENTER OF THE TRENCH. BEND REBAR AND UP TO EXPOSE WORK AREA. SPLICE #3 BARS TO EXISTING RE -BAR, ADD #3 BARS LONGITUDINALLY @ 16" O.G. PROVIDE A VAPOR BARRIER EaUIV. TO 10 MIL. 'STEGOWRAP' BELOW NEW CONCRETE - TAPE NEW VAPOR BARRIER TO EXISTING 3000 P51 CONCRETE INFILL, MATCH EXISTING ADJIAGENT FINISH I SAW CUT DTL, GEMENT STABILIZED SAND NEW PIPING OR CONDUIT N.T. s. 12 qOT USED N T Accessibjfjt Notes: I, MAXIMUM THRESHOLD HEIGHT SHALL BE 1/2" WITH A BEVELED SLOPE NO GREATER THAN 1:2, cf. IN GENERAL, ANY CONTROL MECHANISM REQUIRING USE BY BUILDING 0CGUPANT5 SHALL BE MOUNTED AT 45" A.F.F. MAXIMUM TO 2. OPERATING DEVICES ON ACCESSIBLE DOORS SHALL BE NO HIGHER THE HIGHEST OPERABLE PART OF OBJECT. THE MINIMUM MOUNTING THAN 46" A.F.F. HEIGHT OF ANY CONTROL MECHANISM SHALL BE 15" A.F.F TO THE LOWEST OPERABLE PART OF OBJECT, UNLESS NOTED OTHERWISE. 3. DOOR GLOSERS SHALL BE A TYPE LABELED FOR ACCF-551BILITY TYPICAL ITEMS INCLUDE BUT NOT LIMITED TO ARE: ELECT. AND BE ABLE TO BE ADJUSTED FOR A SWEEP PERIOD 5UGH THAT FROM SWITCHES, TELEPHONE5/TDD'S, THERMOSTATS, ELECT OUTLETS, AN OPEN POSITION OF 10 DEGREES, THE DOOR WILL TAKE AT LEAST DATA TERMINALS, ALARM PULL -STATIONS, DooR BUZZERS, THREE (3) SECONDS MOVE TO AN OPEN POSITION OF APPROXIMATELY 12 DEGREES, lo. GRAB BARS IN RE5TROOMS MUST BE 1-1/4" To 1-1/2" O.D. AND MUST BE INSTALLED To WITHSTAND A LOAD OF 250 LB5 AS DESIGNED. L��USED 4. DOOR CLOSERS SHOULD BE ADJUSTABLE 50 THAT THE OPENING FORGE REQUIRED TO PUSH OR PULL A DOOR OPEN IS 8.5 LBS. 11. ALL EXPOSED DRAIN PIPES AND HOT WATER SUPPLY LINES UNDER MAXIMUM FOR EXTERIOR HINGED DOORS AND 5 LBS, MAXIMUM FOR ACCESSIBLE LAVS/SINKS SHALL BE INSULATED TO PROTECT AGAINST INTERIOR DOORS. THE FORCE REQUIRED SHALL BE MEASURED AS CONTACT. THERE SHALL BE NO SHARP OR ABRA5IVE SURFACES UNDER APPLIED PERPENDICULAR TO THE DOOR AT THE OPENER OR 30 INCHES SINKS. FROM THE HINGED SIDE. 12, SIGNAGE AT DOORS AND OTHER AREAS REQUIRED TO BE 5. ALL DOORS REQUIRING "HAND TW15T" OPERATION SHALL BE ACCESSIBLE SHALL MEET THE FOLLOWING CRITERIA: PROVIDED A "LEVER TYPE" DOOR OPERATOR INSTEAD OF THE TRADITIONAL ROUND KNOB. A. COLOR 4 CONTRAST - CHARACTERS AND BACKGROUND SHALL HAVE A NON GLARE FINISH. CHARACTERS AND THEIR 6, IF ANY ITEM LISTED IN THE HARDWARE SCHEDULE IS NOT AN BACKGROUNDS SHALL HAVE COLORS CONTRASTING TO EACH ACCESSIBLE PRODUCT, IT IS THE RESPONSIBILITY OF THE OTHER. EITHER A DARK CHARACTER ON A LIGHT BACKGROUND OR GENERAL CONTRACTOR TO NOTIFY THE ARCHITECT OF 5UGH AND VICE VERSA, PROVIDE FOR THE ARGHITECT5 REVIEW, IN THE FORM OF SHOP DRAWING SUBMITTALS, AN EQUIVALENT ,hGGES5IBLE PRODUCT. IN B. CHARACTER PROPORTION 4 HEIGHT - LETTERS 4 NUMBERS ON THE EVENT THAT SHOP DRAWINGS ARE NOT SUBMITTED FOR FINISH SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 3:5 HARDWARE, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR I:I AND A STROKE WIDTH To HEIGHT RATIO BETWEEN 1:5 PROVIDING ACCESSIBLE HARDWARE, 1:10, 7. ACCESSIBLE PARKING AND ADJACENT ACCESS AISLES SHALL HAVE C. RAISED BRAILLE CHARACTERS PICTOGRAMS - LETTERS AND SMOOTH TEXTURE AND A MAX. SLOPE OF 2% IN ANY DIRECTIONS. NUMERALS, SHALL BE RAISED 1/32" MINIMUM. UPPERCASE, SIMPLE AGGESSIBLE ROUTES SHALL HAVE A MAX. SLOPE OF 5% IN TYPEFACE ACCOMPANIED WITH GRADE 2 BRAILLE RAISED DIRECTION OF TRAVEL AND 2% GROSS SLOPE. ALL ACCESSIBLE CHARACTERS SHALL BE BETWEEN 5/5" 4 2" IN HEIGHT. CURB RAMPS SHALL HAVE A MAX. SLOPE OF 8.55% (1:12) PICTOGRAMS, WHEN USED, SHALL HAVE A VERBAL DESCRIPTION DIRECTLY BELOW PICTOGRAM. PICTOGRAM BORDER SHALL BE 6" i3. ACCESSIBLE LAVATORY FAUCET CONTROLS SHALL BE LEVER WIDE MINIMUM. OPERATED. PUSH -TYPE OR ELECTRONICALLY ACTIVATED MUST NOT REQUIRE MORE THAN 5 LB OF FORGE TO OPERATE. ANY SELF-GL051N6 VALVES MUST REMAIN IN OPERATION AT LEAST 10 SECONDS, ACCESSIBILITY NOTES N.T.S. z3 �USED LOCATE 5167NA6E / ON STRIKE SIDE / OF DOOR l / \� 1 I 2' ADA COMPLIANT / LEVER TYPE TYPICAL ELEG. SWITCH I MOUNTING HEIGHT - DIMENSION TO CENTER OF DEVICE TYPICAL ELEG. RECEPTACLE MOUNTING HEIGHT - DIMENS1oN TO CENTER OF DEVICE (TYPICAL) HOLLOW GORE WOOD DOOR TO BE PAINTED WITH SEMI -GLOSS ENAMEL OF THE SAME COLOR AS THE WALL ON WHIGH THE DOOR 15 INSTALLED. (UNLESS OTHERWISE NOTED) VT'G. HT. STANDARDS 1/211 PROVIDE WHITE PVG TRIM MOLDING "M350" AT IN51DE CORNERS, "M360" AT OUTSIDE CORNERS, "M365" AT DIVISIONS, AND "M370" AT EXPOSED EDGES. PROVIDE "Mgbl" OUTSIDE CORNER GUARD AT E�;POSED VERTICAL CORNERS. II RESTROOM ELEVATION(TYP.) PROVIDE WHITE PVG TRIM MOLDING "M350" AT INSIDE CORNERS, "M360" AT OUTSIDE CORNERS, "M365" AT DIVISIONS, AND "M370" AT EXPOSED EDGES. PROVIDE "M161" OUTSIDE CORNER GUARD AT EXPOSED VERTICAL CORNERS. N.T.5. 10 IT MIN. TOE GLEE, ENLARGED TOILET :ROOM 4 NOTE: ALL GRAB BARS TO HOLD 250 LB. LOAD MIN. ANCHOR PLATE WELDED TO 16 GA. STUDS AT 16" O.G. (REFER To PLAN FOR DEPTH) Revisions m No. Date Description ® m Qo t aa.aooe u cornHerrr� PARTITION As SCHEDULED THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE IOLLOWING PROJECT: Interior Tenant Impiovernents for: Mattress Finn GRAB BAR - REFER Seminole Town Center TO PLAN FOR LENGTH 695 Town Center Bodevara AND DIAMETER Sanford F(oriaa 32771 300 SERIES STAINLESS STEEL MACHINE 5GREWS 1-1/2" LONG 12 GAUGE STEEL ANCHOR PLATE WITH 1/411- 20 THREADED HOLES 200 INCH MIN. USABLE THREAD PER HOLE GRAB BAR DETAIL N.T.S. MARLITE 5-100 SMOOTH WHITE FRP PANEL TO 48" A.F.F. (RE: SCHEDULE FRP-I) TOILET LINE OF NEW GEILING (AG -I) GYP. BD. WALL(PAINT P-5) NEW HDGP GRAB BAR NEW TOILET TISSUE HOLDER SCHEDULED FLOORING AND BASE NOTE: MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE 'REFLEGTING 5URFAGE' NO HIGHER THAN 40 INCHES (1015 MM) MAX A.F.F.; THE TOP OF THE 'REFLEGTI NG 5URFAGE' SHALL BE AT LEAST 74 IN. (1880 MM) A.F.F. AT THE TOPMOST EDGEOil1/411 E�03D GYP. BD WALL (PAINT P-5) LINE OF NEW MARLITE 5-100 GEILING (AG --I) SMOOTH WHITE FRP PANEL TO 48" A.F.F. NEW 2'-0" X 3'-O" (RE: SCHEDULE FRP-I) \� STAINLE55 STEEL FRAMED MIRROR GRAB BAR, CONGEALED MOUNTING WITH SNAP FLANGE r 36" # 42" MINIMUM LENGTH (RE: 04/A-5) o m STAINLESS STEEL CHANNEL FRAMED MIRROR 24"x36" %g %__ 0 0. - B.O. REFLEGTI VE SURFACE 40" MAX. - T.O. REFLECTIVE SURFACE 74" MIN. (N 50AP DISPENSER 6. ACCESSIBLE SIGNAGE (RE 08/A-5) 7. NEW E.D.F. 8. NEW 3'-0" x T -O" H.G. WD. DOOR 4 FRAME, W/ LEVER HARDWARE, LOOK, KICKPLATE, s CLOSER (HOLD BOTTOM OF DOOR I" A.F.F) q. INFILL AREA OF EXISTING CONCRETE SLAB "LEAVE OUT" AS NOTED BELOW. TRENCH NEW PLUMBING LINE TO SINK EXISTING STUB UP. KWE NEW FLOOR MOUNTED MOP 51 NK (RE: MEP) NOTE: FEFER GLR. II RESTROOM ELEVATION(TYP.) PROVIDE WHITE PVG TRIM MOLDING "M350" AT INSIDE CORNERS, "M360" AT OUTSIDE CORNERS, "M365" AT DIVISIONS, AND "M370" AT EXPOSED EDGES. PROVIDE "M161" OUTSIDE CORNER GUARD AT EXPOSED VERTICAL CORNERS. N.T.5. 10 IT MIN. TOE GLEE, ENLARGED TOILET :ROOM 4 NOTE: ALL GRAB BARS TO HOLD 250 LB. LOAD MIN. ANCHOR PLATE WELDED TO 16 GA. STUDS AT 16" O.G. (REFER To PLAN FOR DEPTH) Revisions m No. Date Description ® m Qo t aa.aooe u cornHerrr� PARTITION As SCHEDULED THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE IOLLOWING PROJECT: Interior Tenant Impiovernents for: Mattress Finn GRAB BAR - REFER Seminole Town Center TO PLAN FOR LENGTH 695 Town Center Bodevara AND DIAMETER Sanford F(oriaa 32771 300 SERIES STAINLESS STEEL MACHINE 5GREWS 1-1/2" LONG 12 GAUGE STEEL ANCHOR PLATE WITH 1/411- 20 THREADED HOLES 200 INCH MIN. USABLE THREAD PER HOLE GRAB BAR DETAIL N.T.S. MARLITE 5-100 SMOOTH WHITE FRP PANEL TO 48" A.F.F. (RE: SCHEDULE FRP-I) TOILET LINE OF NEW GEILING (AG -I) GYP. BD. WALL(PAINT P-5) NEW HDGP GRAB BAR NEW TOILET TISSUE HOLDER SCHEDULED FLOORING AND BASE NOTE: MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE 'REFLEGTING 5URFAGE' NO HIGHER THAN 40 INCHES (1015 MM) MAX A.F.F.; THE TOP OF THE 'REFLEGTI NG 5URFAGE' SHALL BE AT LEAST 74 IN. (1880 MM) A.F.F. AT THE TOPMOST EDGEOil1/411 E�03D GYP. BD WALL (PAINT P-5) LINE OF NEW MARLITE 5-100 GEILING (AG --I) SMOOTH WHITE FRP PANEL TO 48" A.F.F. NEW 2'-0" X 3'-O" (RE: SCHEDULE FRP-I) \� STAINLE55 STEEL FRAMED MIRROR s FLUSH VALVE LEVER ON WIDE 51DE OF TOILET (TYP) I►01 p HOLp SCHEDULED FLOORING AND BASE NOTE: MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE 'REFLECTING SURFACE' NO H164ER THAN 40 INCHES (1015 MM) MAX A.F.F.; THE TOP OF THE 'REFLECTI NO 5URFAGE' SHALL BE AT LEAST 74 IN. (18850 MM) A.F.F. AT THE TOPM05T EDGE (ESTROOM ELEVATION (TYP.) 1/411 = 11-C Off. Bat broom Accessories I SURFACE MOUNTED TOILET TISSUE HOLDER 2 SURFACE MOUNTED PAPER TOWEL DISPENSER 3. GRAB BAR, CONGEALED MOUNTING WITH SNAP FLANGE r 36" # 42" MINIMUM LENGTH (RE: 04/A-5) o m STAINLESS STEEL CHANNEL FRAMED MIRROR 24"x36" %g %__ 0 0. - B.O. REFLEGTI VE SURFACE 40" MAX. - T.O. REFLECTIVE SURFACE 74" MIN. (N 50AP DISPENSER 6. ACCESSIBLE SIGNAGE (RE 08/A-5) s FLUSH VALVE LEVER ON WIDE 51DE OF TOILET (TYP) I►01 p HOLp SCHEDULED FLOORING AND BASE NOTE: MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE 'REFLECTING SURFACE' NO H164ER THAN 40 INCHES (1015 MM) MAX A.F.F.; THE TOP OF THE 'REFLECTI NO 5URFAGE' SHALL BE AT LEAST 74 IN. (18850 MM) A.F.F. AT THE TOPM05T EDGE (ESTROOM ELEVATION (TYP.) 1/411 = 11-C Off. Bat broom Accessories I SURFACE MOUNTED TOILET TISSUE HOLDER 2 SURFACE MOUNTED PAPER TOWEL DISPENSER 3. GRAB BAR, CONGEALED MOUNTING WITH SNAP FLANGE 36" # 42" MINIMUM LENGTH (RE: 04/A-5) 4- STAINLESS STEEL CHANNEL FRAMED MIRROR 24"x36" - B.O. REFLEGTI VE SURFACE 40" MAX. - T.O. REFLECTIVE SURFACE 74" MIN. 5. 50AP DISPENSER 6. ACCESSIBLE SIGNAGE (RE 08/A-5) 7. NEW E.D.F. 8. NEW 3'-0" x T -O" H.G. WD. DOOR 4 FRAME, W/ LEVER HARDWARE, LOOK, KICKPLATE, s CLOSER (HOLD BOTTOM OF DOOR I" A.F.F) q. INFILL AREA OF EXISTING CONCRETE SLAB "LEAVE OUT" AS NOTED BELOW. TRENCH NEW PLUMBING LINE TO EXISTING STUB UP. 10, NEW FLOOR MOUNTED MOP 51 NK (RE: MEP) NOTE: FEFER TO 02/A-5 4 03/A5 FOR TYPICAL MOUNTING HEIGHTS 1/41 W �'-O" - 01 , THEY ARE NOT SUITABLE FOR USE ON OTHER i Plt EUIS OR IN OTHER LOCA'T'IONS WITHOUT' TFIE APPROVAL AND PARTICIPATION OF 1'HE ARCHITECT. REPRODUCTION IS PROH18TTEO, j COPYIZIGEIT zoW LACY L. CHiZISTIE1i�N/ A.I.A. Lary i ristian I i AILAO 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 .9756 Expires; 02,28.09 Larry L. Christian, A.1 -A. Florida Architectural Registration #AR -0010755 ENL4RGEo PLAN, ELEVATIONS AND DETAILS A-5 ® ® G Date: 07.28,2008 j _ Project No. 0805-776 NOT USED 07/A6 O6/A6 VARIES, RE, A-3 PARTITION TYPES LIMITINb HHSNT Op PARTITIGH DATA CQWLW FROM U9b, DRYY FPM FN& 9TANPARM 0Q0p O o O 6 o p 0 0 0 0 0 0 0 0 0 0 0 o a j j j I I I I I I I I I I I I I I I I I I I I o uo b, o iv i7 iv co a> o i, in io r, ao 0) N N N N N N Qq. 21/2"25 22 GQ. MTL. STUD AT 16" O.C. HORIZONTAL CHANNEL BRIDGING GYP. BD. ONE SIDE ONLY N \ 15, -pI 1 I I I I `6 q 21/2" AT 48" O.C. VERTICAL MTL. STUD AT 16" O.C. 20 Gq. Cl ■ C 25 Gq 358„ 22 cq \ 20 Ga. GYP. EIR. ONLY G.G, TO PROVIDE 2-LAYER5 3-5/8" TYPE 'X' GYP , 35/� 25 Gq PETAIL5 4 NOTES 22 G q.. MTL. STUD AT 16" O.C. BOARD (EACH SIDE) OVER EXISTING 6" AND GYP, BD. BOTH SIDES ,y+� 25 G q. 0 CONTINUE TO UNDERSIDE OF EXISTING ROOF M. STUD AT 16" 20 Go. \� 6,7 DECK. FINISH A5 SCHEDULED. (2 -HOUR FIRE OI 22 Gq ( J 20 Gu. GYP. BD. BOTH SIDES RATED PER UL DESIGN NO.: U4111). 05/A6 (7 R-13 BATT INSULATION C-_', (FULL HEIGHT) Illy ,I, I I ITh dI lY 11 h . IIIV'IIIuIRIII'IIIIIPdIVIIVI Ii 1 l al l''If VIVPIIIIIIIIIIRIIIIIIIIIIIIIVR9111111111111PPIII111' q''.11,«a1,i,IIIIIIIRdIIIV911VIIVIIIVIIIIIIIIIIIIIII!!III PIIIG r 1. ,, lv I,o IIuPdiflllliRlllll!IIIIIIV I7 r3" - SCHEDULED BASE UL OF -516N 4111 W/ UL HW -0-0060 SLIP JOINT (PERPENDICULAR 4 PARALLEL TO METAL DECK) (RE: SHEET A-0.5 FOR UL DETAIL INFORMATION) PARTITION TYPES LIMITINb HHSNT Op PARTITIGH DATA CQWLW FROM U9b, DRYY FPM FN& 9TANPARM 0Q0p O o O 6 o p 0 0 0 0 0 0 0 0 0 0 0 o a j j j I I I I I I I I I I I I I I I I I I I I o uo b, o iv i7 iv co a> o i, in io r, ao 0) N N N N N N 911NIIIIIRI'allll " rl�llY�RIIVIIVIIIIIIIIIIIIIIIIIIIIIIIIIIYIIIIIIIIIdI,:hi'r �'��✓�uudl��N'�1NIINNIIIPII 12'-0"�- Qq. 21/2"25 22 GQ. MTL. STUD AT 16" O.C. 20 Ga. GYP. BD. ONE SIDE ONLY N N C 15, -pI 1 I I I I `6 q 21/2" zz Ga MTL. STUD AT 16" O.C. 20 Gq. GYP. BD. BOTH SIDES ■ C 25 Gq 358„ 22 cq D.r ONE SIDE 20 Ga. GYP. EIR. ONLY OR VINYL BASE AS 50HED. , 35/� 25 Gq PETAIL5 4 NOTES 22 G q.. MTL. STUD AT 16" O.C. 20 GO. GYP, BD. BOTH SIDES ,y+� 25 G q. 0 22 M. STUD AT 16" 20 Go. GYP. BD. BOTH SIDES 6,7 25 Go. OI 22 Gq MTI. STUD AT 16" O.C. 20 Gu. GYP. BD. BOTH SIDES 911NIIIIIRI'allll " rl�llY�RIIVIIVIIIIIIIIIIIIIIIIIIIIIIIIIIYIIIIIIIIIdI,:hi'r �'��✓�uudl��N'�1NIINNIIIPII 12'-0"�- 3 5/8" METAL STUDS AT 16" O.G. Florida Architectural Registration N N N C 15, -pI 1 I I I I `6 q ,� 2 1/2" SOUND ATTENUATION i1 BLANKET 05/A6 ■ C '- �;!Illilll,llui111'NNIINIuRIIPVhIIWRhlhhl'I!9im Y �I'null'llllllllllkl'9tlull�alwr'V'11h. r' �1 dil'lllllp+�"^ 13'x" j Ixb WOOD BASE (PAINT) PARTITION PrPE5, OR VINYL BASE AS 50HED. G * WATER RE51STANT GYP. BD. PETAIL5 4 NOTES I I I 1�1-�il I A-6 Pq Date: 07.28.2008 OI Project No. 0805-776 R'19i 1+, ,II IalNI,IIIIIIIIIIIIIIIIIuIIRIIIIIIIIIIII p',°+,pyl1','uI�IIPVIIINIP9V6IlIIP'IVIUININI§ +r„M.<'.41 V RRI�RRIIIIIRIIRI IIII,{,V;i ”. I6'—O" 1� Illy ,I, I I ITh dI lY 11 h . IIIV'IIIuIRIII'IIIIIPdIVIIVI Ii 1 l al l''If VIVPIIIIIIIIIIRIIIIIIIIIIIIIVR9111111111111PPIII111' q''.11,«a1,i,IIIIIIIRdIIIV911VIIVIIIVIIIIIIIIIIIIIII!!III PIIIG r 1. ,, lv I,o IIuPdiflllliRlllll!IIIIIIV I7 r3" - f. a•uhull 111i r lI II pll R , r,. w I 6 IINIIIIIIIIIEII"t�s�s.r...,i.1111111111ullfllllll611111iud.1,�..rw.,u1„�IuuIN11u111111111uIIIIIIIIIIIIIIIIIIIIIIIwIIIIu�iIIII,I,u,III,uV�INIIIIIIiIIIIIIIIuIIRIIIIIIIIIIuIIIIIIIIIIIIIIIhIIIIIaIM�ad ti1,,�.�111NllgN �' 1 119 I —6 I 1 I a0 -0 .I G . ,x ulllu II 117 'lllll,�l"I�dk, .,�,Nd1�161u11IVI�`�",r�,�'.,la,n,�,.ac„�"V�IRI16hNl°�I�Iaw,.•.� , d�itil>w��ukIVV6RuNRhlflyd�+a,ua�n,,,„�,°��16VI11hIldVdI�In91dV14dul'RIIG1dfd,��,k s ,fll1 � IIuIV,IIR611V1111111111IIIIPi�IIVIf:IINoI.r.�,w,� ,IIo11 I II I „ul IIII ,nilmw, w ��I Il , „111;,1 l,,r.o l „t�.IIiIIduIIR'� 28-3 1 INTERIOR METAL STUD HEIGHT LIMIT CHART N.T.5. PAINTED WALL (TYPICAL) 5/8" GYP. BD. WOOD DOOR HOLLOW CORE DOOR AND Fl RE, PARTITION 5GHEDULE (JAME3 SIMILAR) TREATED WOOD 6iDER AT DOOR ENING5 DOOR HEADER 311 11-011 rm bl AAI n 1 HOLLOW GORE WOOD DOOR AND FRAME (HOLD BOTTOM OF DOOR ® I" A.F.F) DOOR TYPES 1/2" 1'-0" 14 13 CARPET OR VCT 3-5/8" DIAGONAL STUD BRACE AT 48" D.G. iTr VARIES, RE: A-3 5U5P, ACOUSTICAL GEILING 06/A6 L/ 11 Try AAV1 Irl �kI r+.r►w In CERAMIC, TILE OR LAMINATE WOOD FLOORING v:rl Y LItJnL ,-/I Y IDER VINYL TRANSITION STRIP (TYPICAL) ALL TRAN51TIONS (UNO) TRANSITION DETAIL N.T.S. NOT USED N.I.S. Elo 09 BOTTOM OF DECK VARIES, RE: A-3 5U5P. AGOU5TIGAL CEILING 3 5/b" METAL 5TUD5 AT 16" O.G. R-13 BATT INSULATION (FULL HEIGHT) I x6 WOOD BASE (PAINT) OR VINYL BASE AS 50HED. GYP. BD. ON STUD AT EXT. WALL CONTINUOS TO UNDERSIDE OF DECK. EXTEND METAL 5TUD5 AND INSULATION TO UNDERSIDE OF DECK. TOP OF METAL DECK FIRE RATED GYPSUM COMPOUND OR FIRE CAULK Z -CLIP 2" WIDTH BOTTOM OF METAL DECK FIRE TRAK SHADOWL I NE -LAYERS R53- 5/ TYPE I IG.G. TO PROVIDE 2 GYP BOARD (EACH SIDE) OVER EXISTING 6" AND GOINUE TO UNDERSIDE OF EXI5TIN& ROOF DECK. FIN15H AS SCHEDULED. (2 -HOUR FIRE RATED PER UL DESIGN NO.: U4110. HEAD DETAIL - UL HW -D-0060 PARALLEL 4 PERPENDICULAR TO METAL DECK (2 HR. RATING) - I" DEFLECTION UL DESIGN U4M W/ HW -D-0060 SLIP TRACK (PER PIRETRAK) AT RATED SEPARATION WALL (WALL TYPE 'B' ONLY) DATED SLIP JOINT 1 1/2:1 = II -DTI SCHEDULED 5/8" TYPE 'X' GYP. BD. W/ 50HEOULED FIN15H MTL. STUDS @ 16" O.G.. 16 &A. CONT. U -CHANNEL BRIDGING ELEV = 48" O.G.. TYP. I I/2" x 11/2" x 16 GAGE CLIP ANGLE ® 48" O.C. VERT. 4 HORIZ., ATTACHED TO STUD AND U -CHANNEL W/ (2) #10 TEK SCREWS PER CONNECTION NOTE: CLIP ANGLE LENGTH SHALL NOT BE LF -55 THAN 1/2" OF STUD DEPTH BRIDGING DETAIL (TYP.) 1 1/211 = 11 -DTI RE: PLAN SCHEDULED 5/8" TYPE 'X' GYP. BD. W/ 50HEDULED FINISH I `` I MTL. STUDS @ 16" O.G. AT SCHEDULED BAS SCHEDULED FLOOR TOP OF SLAB ELEV = 0'-0" CONT. &ALV. TRACK EXISTING CONCRETE SLAB ANCHOR TRACK TO CONCRETE SLAB W/ 0.145 DIA, POWDER ACTUATED FASTENERS @ 12" O.G.. STAGGERED (TYP) METAL, TRACK BASE DETAIL Iva" = I'—o.. 07 EXISTING EXTERIOR WALL CONSTRUCTION Revlslons' ® No. Date Description® o-r/A6 I DIAGONAL STUD ME 0-122.200D LL COMNT5 I BRACE AT 48" O.G. �I. VARIES, RE: A-3 06/A6 L 05/A6 I SUSPENDED ACOU5TIGAL CEILING 3 5/8" METAL STUDS AT 162" O.G. 5/8" GYP. BD. Ix6 WOOD BASE (PAINT) I OR VINYL BASE AS SGHED. Partition Gene -rat Notes: I. TESTING AGENCY DESIGNATIONS INDICATED FOR FIRE RATED PARTITIONS ARE GIVEN TO DE50RIBE CONSTRUCTION REQUIREMENTS ONLY: THEY ARE NOT INTENDED TO LIMIT MANUFACTURERS OF MATERIALS, COMPLY WITH THE CONSTRUCTION REQUIREMENTS OF THE INDICATED DESIGN. 2. SUSPENDED CEILING SYSTEMS SHALL NOT BE USED AS BRACING. 3, WALLS DESIGNATED AS FIRE RESISTIVE WILL USE TYPE "X" GYPSUM BOARD. SEE PLANS FOR LOCATIONS. 4. STUDS EXCEEDING 12'-0" HEIGHT REQUIRE MID HEIGHT BRACING. 5. ASSEMBLIES WITHOUT FACE PANELS AND CHASE WALL PARTITIONS SHALL HAVE VERTICAL CROSS BRACING AT 4'-0" MAXIMUM. 6. WATER RE51STANT GYP. BD. ® ALL NET AREAS (TYP) GENERAL NOTES NT5 SHOWROOM CEILING HEIGHT + 12'-0" A.F.F. SHOWROOM L06 5/8" GYP. BOARD ON 3-5/8" METAL STUDS 16" O.G. (PAINT) VALUE GENTER CEILING HEIGHT + c1' -q" A.F.F. BOTTOM OF FURR-DOWN L051 + 8'-9" A.F.F i 4 SECTION AT VALUE CENTER O4 - °3 I DIAGONAL BRACING AS REQUIRED 4' - 2 LAMP FLUORE50ENT STRIP LIGHT, MOUNT END TO ® i THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWINC2 PROJECT: Interior Tenant Improvements for: Mattress Firm Seminole Town Center 695 Town Center Bodevarb San f orbs Eforiba 39771 THEY AU, NOT SUITABLE POR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBITED. COPYXIGHT 9oo8 LARRY L. CHRISTIAN, I.A. ■ ■ 3 5/8" METAL STUDS AT 16" O.G. Florida Architectural Registration #AR -0010755 ,� 2 1/2" SOUND ATTENUATION i1 BLANKET 05/A6 ■ C '- L j Ixb WOOD BASE (PAINT) PARTITION PrPE5, OR VINYL BASE AS 50HED. G * WATER RE51STANT GYP. BD. PETAIL5 4 NOTES ALL NET AREAS (TYP) L/ 11 Try AAV1 Irl �kI r+.r►w In CERAMIC, TILE OR LAMINATE WOOD FLOORING v:rl Y LItJnL ,-/I Y IDER VINYL TRANSITION STRIP (TYPICAL) ALL TRAN51TIONS (UNO) TRANSITION DETAIL N.T.S. NOT USED N.I.S. Elo 09 BOTTOM OF DECK VARIES, RE: A-3 5U5P. AGOU5TIGAL CEILING 3 5/b" METAL 5TUD5 AT 16" O.G. R-13 BATT INSULATION (FULL HEIGHT) I x6 WOOD BASE (PAINT) OR VINYL BASE AS 50HED. GYP. BD. ON STUD AT EXT. WALL CONTINUOS TO UNDERSIDE OF DECK. EXTEND METAL 5TUD5 AND INSULATION TO UNDERSIDE OF DECK. TOP OF METAL DECK FIRE RATED GYPSUM COMPOUND OR FIRE CAULK Z -CLIP 2" WIDTH BOTTOM OF METAL DECK FIRE TRAK SHADOWL I NE -LAYERS R53- 5/ TYPE I IG.G. TO PROVIDE 2 GYP BOARD (EACH SIDE) OVER EXISTING 6" AND GOINUE TO UNDERSIDE OF EXI5TIN& ROOF DECK. FIN15H AS SCHEDULED. (2 -HOUR FIRE RATED PER UL DESIGN NO.: U4110. HEAD DETAIL - UL HW -D-0060 PARALLEL 4 PERPENDICULAR TO METAL DECK (2 HR. RATING) - I" DEFLECTION UL DESIGN U4M W/ HW -D-0060 SLIP TRACK (PER PIRETRAK) AT RATED SEPARATION WALL (WALL TYPE 'B' ONLY) DATED SLIP JOINT 1 1/2:1 = II -DTI SCHEDULED 5/8" TYPE 'X' GYP. BD. W/ 50HEOULED FIN15H MTL. STUDS @ 16" O.G.. 16 &A. CONT. U -CHANNEL BRIDGING ELEV = 48" O.G.. TYP. I I/2" x 11/2" x 16 GAGE CLIP ANGLE ® 48" O.C. VERT. 4 HORIZ., ATTACHED TO STUD AND U -CHANNEL W/ (2) #10 TEK SCREWS PER CONNECTION NOTE: CLIP ANGLE LENGTH SHALL NOT BE LF -55 THAN 1/2" OF STUD DEPTH BRIDGING DETAIL (TYP.) 1 1/211 = 11 -DTI RE: PLAN SCHEDULED 5/8" TYPE 'X' GYP. BD. W/ 50HEDULED FINISH I `` I MTL. STUDS @ 16" O.G. AT SCHEDULED BAS SCHEDULED FLOOR TOP OF SLAB ELEV = 0'-0" CONT. &ALV. TRACK EXISTING CONCRETE SLAB ANCHOR TRACK TO CONCRETE SLAB W/ 0.145 DIA, POWDER ACTUATED FASTENERS @ 12" O.G.. STAGGERED (TYP) METAL, TRACK BASE DETAIL Iva" = I'—o.. 07 EXISTING EXTERIOR WALL CONSTRUCTION Revlslons' ® No. Date Description® o-r/A6 I DIAGONAL STUD ME 0-122.200D LL COMNT5 I BRACE AT 48" O.G. �I. VARIES, RE: A-3 06/A6 L 05/A6 I SUSPENDED ACOU5TIGAL CEILING 3 5/8" METAL STUDS AT 162" O.G. 5/8" GYP. BD. Ix6 WOOD BASE (PAINT) I OR VINYL BASE AS SGHED. Partition Gene -rat Notes: I. TESTING AGENCY DESIGNATIONS INDICATED FOR FIRE RATED PARTITIONS ARE GIVEN TO DE50RIBE CONSTRUCTION REQUIREMENTS ONLY: THEY ARE NOT INTENDED TO LIMIT MANUFACTURERS OF MATERIALS, COMPLY WITH THE CONSTRUCTION REQUIREMENTS OF THE INDICATED DESIGN. 2. SUSPENDED CEILING SYSTEMS SHALL NOT BE USED AS BRACING. 3, WALLS DESIGNATED AS FIRE RESISTIVE WILL USE TYPE "X" GYPSUM BOARD. SEE PLANS FOR LOCATIONS. 4. STUDS EXCEEDING 12'-0" HEIGHT REQUIRE MID HEIGHT BRACING. 5. ASSEMBLIES WITHOUT FACE PANELS AND CHASE WALL PARTITIONS SHALL HAVE VERTICAL CROSS BRACING AT 4'-0" MAXIMUM. 6. WATER RE51STANT GYP. BD. ® ALL NET AREAS (TYP) GENERAL NOTES NT5 SHOWROOM CEILING HEIGHT + 12'-0" A.F.F. SHOWROOM L06 5/8" GYP. BOARD ON 3-5/8" METAL STUDS 16" O.G. (PAINT) VALUE GENTER CEILING HEIGHT + c1' -q" A.F.F. BOTTOM OF FURR-DOWN L051 + 8'-9" A.F.F i 4 SECTION AT VALUE CENTER O4 - °3 I DIAGONAL BRACING AS REQUIRED 4' - 2 LAMP FLUORE50ENT STRIP LIGHT, MOUNT END TO ® i THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWINC2 PROJECT: Interior Tenant Improvements for: Mattress Firm Seminole Town Center 695 Town Center Bodevarb San f orbs Eforiba 39771 THEY AU, NOT SUITABLE POR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBITED. COPYXIGHT 9oo8 LARRY L. CHRISTIAN, I.A. ■ ■ ■ .-. ristiam AT • ® • ■ 3801 KirbyDrSuit60 .e o Houston, Texas 77090 tel: 713 664 7974 fax: 713 664 9756 6.01 7'�� L7■1 END CONT. (RE: D' 02/A-3) Expires: 02.28.09 Lary L. Christian, A.I.A. Florida Architectural Registration #AR -0010755 ■ ■ ■ '- DOOR 50HEi7ULES, PARTITION PrPE5, PETAIL5 4 NOTES I A-6 Pq Date: 07.28.2008 OI Project No. 0805-776 1� ■ .-. ristiam AT • ® • ■ 3801 KirbyDrSuit60 .e o Houston, Texas 77090 tel: 713 664 7974 fax: 713 664 9756 6.01 7'�� L7■1 END CONT. (RE: D' 02/A-3) Expires: 02.28.09 Lary L. Christian, A.I.A. Florida Architectural Registration #AR -0010755 ■ ■ ■ DOOR 50HEi7ULES, PARTITION PrPE5, PETAIL5 4 NOTES I A-6 Date: 07.28.2008 OI Project No. 0805-776 1� CEILING Revisions LIGHT 5EN50R DOOR CLOSER THIS DRAWING IS NOT INTENDED TO COVER ALL ACCESSIBILITY REQUIREMENTS, BUT No. Date Description WALL MOUNTED >0SCHEDULED DOOR 51r -,N SHALL RATHER TO HIGHLIGHT AREAS OF COMMON CONCERN. VERIFY ALL ACCESSIBILITY SMOKE DETECTOR CONFORM WITH REQUIREMENTS WITH THE ADA AND LOCAL ACCESSIBILITY REQUIREMENTS. THE DETAILS Q01.22200e$ LL COMMENT5 CURRENT STATE ON THI5 SHEET INDICATE GENERAL ACCESSIBLE REQUIREMENTS. THEY ARE TO BE USED FIRE ALARM STROBE �� AND LOCAL AS INFORMATION AND AS A GUIDELINE FOR SITUATIONS NOT DESCRIBED ON MORE FIRE ALARM MANUAL GODE5 AND SPECIFIC DRAWINGS. IT 15 THE GENERAL CONTRACTOR'S RESPONSIBILITY TO APPLY THE PULL STATION SCHEDULED THRESHOLD SET REGULATIONS DETAILS AS REQUIRED. IF ANY OF THE DETAILS ON THI5 SHEET CONFLICT WITH OTHER IN FULL BED OF MASTIC G.G. TO PROVIDE 8 - CONSTRUCTION DOCUMENTS NOTIFY THE ARCHITECT OF RECORD. STANDARDS ARE TELEPHONE OUTLET (I/2 SADDLE AT GER. TILE) REST ROOM AX' \\ BASED ON AN51-AI17.1 MORE STRINGENT REQUIREMENTS BY FEDERAL OR LOCAL DATA OUTLET SIGNAGE AND \ -JURISDICTIONSHALL TAKE PRECEDENCE. MOUNT SIGN ~ ST ROOM THERMOSTAT LATCH SIDE OF DOOR MR ROUTES: MOP HOLDER 50HEOULE v POOR. SIGN SHALL _ z I. THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE SHALL BE 36 IN. EXCEPT AT WALL 5WITGH CONFIRM WITH 4 I I SERVICE FAUCETS CURRENT STATE "' - POOR I I DOORS. DOORWAYS WITH A MAXIMUM DEPTH OF 24 IN. SHALL HAVE A MINIMUM CLEAR MISCELLANEOUS ,o - 4 HARDWARE PER !CLEAR I �- AND CONTROLS AND LOCAL CODES I I OPENING OF 32 IN. WITH THE DOOR OPEN 10 DEGREES. MEASURED BETWEEN THE FAGS m - _ IFLOOR I OF THE DOOR AND THE OPP051 TE STOP. THESE DOCUMENTS HAVE BEEN PREPARED RECEPTACLE v 4 CHAN6E5 IN LEVEL UP TO 1/4" MAY BE VERTICAL AND SCHEDULE m N ? �SPAG SPECIFICALLY POR THE FOLLOWING PRCJEcr: in m MOP SINK WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN 1/4" Interior Tenant Irnprovernents for: asr p 0 0 _ AND 1/2 SHALL BE BEVELED WITH A SLOPE NO GREATER 2, WALKS: SLOPE SHALL NOT EXCEED 5% IN THE DIRECTION OF TRAVEL OR 2% IN I LIGHT SENSOR " 15 GROSS SLOPE. IYlattress Firrn MIN. 30" MIN. I FINISH FLOOR � THAN 1:2. GRANGES IN LEVEL GREATER THAN I/2" SHALL BE 5e�ninote Torvn Center - - ACCOMPLISHED BY MEANS OF AN ADA ACCESSIBLE RAMP. 3. PARKING: SLOPE WITHIN ACCE551BLE PARKING SPACES SHALL BE LESS THAN 2% IN 695'i'oim Center Bowfevarb Sanf orb, P(oriba 32771 ANY DIRECTION. THEY ARE NOT SUITABLE FOR USE ON OTHER DETAIL 1/4" ^ 1'-0" 3o MOUNTING HEIGHTS N.T.S. 25 CHANGES IN LEVEL N.T.S. " _ '- " _110 4. CURB RAMPS: SHALL NOT EXCEED A SLOPE OF 8%, AND "FLARED 51DE5' ARE TO BE THE APPROVAL OVALAOR tN DPARTICIPATION ARTICIPHER I TIONNS O THE 20 TOL. RMS. SIGNAGE v4 I O I LAV. CLEARANCES I/4 1 -O TIIEAPPROVALANDPARTICIPATIONOP`1'HE A MAX. OF 10% MIN. WIDTH 15 36 MIN. CURB RAMPS SHALL HAVE A DETECTABLE ARCHITECT. REPRODUCTION IS PROHIBITED. PROJECTWARNING CON5ISTING OF RA15ED TRUNCATED DOMES WITH A DIAMETER OF NOMINAL o.q COPYRIGHT 2oo8 11"-Iq" IN., A HEIGHT OF NOMINAL 2.35 IN., AND SHALL CONTRAST VISUALLY WITH ADJOINING LARRY L. CHRISTIAN, A.I.A. 30 SURFACES, EITHER LIGHT -ON -DARK, OR DARK -ON -LIGHT. 2'-6" 2' O" 10 M 5. ENTRANCES: MANEUVERING AREA AT LANDINGS AT ALL ENTRANCES 15 LEVEL, THE 01 LINE OF FINISH WALL MAXIMUM SLOPE SHALL NOT EXCEED 2%. - �---'�`- IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR w 6. HANDRAILS: (IF REQUIRED) SHALL BE INSTALLED BETWEEN 34" AND 36" ABOVE SURFACE, THEN IT SHALL BE SECURELY ATTACHED; HAVE A FIRM '�� 11 RAMPS. CUSHION OR PAD; AND HAVE A LEVEL LOOP, TEXTURED LOOP, MIRROR MIN. LEVEL GUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. THE W MIN.111 DOORS AND HARDWARE: MAXIMUM PILE THICKNESS SHALL BE 1/2". EXPOSED EDGES OF 6" MAX. ADA COMPLIANT SINK CARPET SHALL BE FASTENED TO FLOOR SURFACES AND HAVE AND FAUCET I. REFER TO HARDWARE 5GHEDULE FOR MOUNTING HEIGHTS. TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. A. WALL AND P05T MOUNTED CANTILEVER FOUNTAINS SHALL 2. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 1/2" IN HEIGHT. RA15ED THRESHOLDS 12" MAX. HAVE CLEAR KNEE SPACE AS FOLLOWS: _ AND FLOOR LEVEL GHAN6E5 AT ACCESSIBLE DOORWAYS SHALL BE BEVELED WITH A / PREDOMINANT DIRECTION I. MINIMUM 27 HIGH (FROM APRON BOTTOM TO FLOOR) _ SLOPE NO GREATER THAN 1:2. rz� F MINIMUM 30" WIDE, AND 17" - Iq" DEEP. ° PULLS, LATCHES, LOOKS AND OTHER OPERATING DEVICES ON ACCESSIBLE � Qj OF TRAFFIC; 3. RANDLES, z 2. A MINIMUM 30" BY 48" CLEAR FLOOR SPACE DOORS SHALL HAVE A SHAPE THAT 15 EASY TO GRA5P WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. ALLOWING A FORWARD APPROACH TO THE UNIT SHALL �„ 6„ LEVER -OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U -SHAPED HANDLES ARE ° IF GRATINGS ARE LOCATED IN WALKING SURFACES, THEY SHALL BE PROVIDED, ACCEPTABLE DE5I6N5. HARDWARE REOUIREP FOR ACCESSIBLE DOOR PASSAGE SHALL HAVE SPAGE5 NO GREATER THAN 1/2" WIDE IN ONE DIRECTION. IF B. FREE STANDING OR BUILT-IN UNITS NOT HAVING A CLEAR KNEE TOE BE MOUNTED NO HIGHER THAN 48 IN. A.F.F. GRATINGS HAVE ELONGATED OPENINGS THEN THEY SHALL BE GLR GLR. PLACED 50 THAT THE LONG DIMENSION IS PERPENDICULAR TO KNEE 5PAGE SHALL HAVE A MINIMUM 30" BY 48" CLEAR THE DOMINANT DIRECTION OF TRAVEL. FLOOR SPACE ALLOWING A PARALLEL APPROACH TO THE 4. IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ® _ UNIT. ADJUSTED 50 THAT FROM AN OPEN P051TION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TD A POINT 3 INCHES FROM LATCH, MEASURED TO THE SIDE REACH N.T.S. 29 REACH LIMITS N.T.5. 24 LwALIKING SURFACES N.T.S. z9 D. F. CLEARANCES N.T.5. I�} LAV. CLEARANCES 1/4" = I' -O" 09 LEADING EDGE OF THE DOOR. 5. THE MAXIMUM FORGE FOR PUSHING OR PULLING OPEN AN INTERIOR HINGED DOOR SHALL BE 5 �LBS. THESE FORGES DO NOT APPLY TO THE FORGE REQUIRED TO RETRACTCD SFE P1 AN5 LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT MAY HOLD THE DOOR IN A CLOSED :v POSITION. " �' ® ;:z X GROUND 4 FLOOR SURFACES: SCHEDULED GRAB BAR A ° I. GROUND AND FLOOR SURFACE ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE 48" 4 ROOMS AND SPACES INCLUDING, FLOORS, WALK5, RAMPS, STAIRS, AND GURB RAMPS, CD SHALL BE STABLE, FIRM AND SLIP -RESISTANT. CONTROLS 4 OPERATING MECHANISMS: c �y ry A. THE HIGHEST OPERABLE PART OF 7M1✓ TELEPHONE SHALL BE "- 36" MIN. I. CONTROLS AND/OR MEGRAN15M5 SHALL BE OPERABLE WITH ONE HAND AND SHALL 11/2" 48 MAXIMUM ABOVE THE FLOOR WHER1r A FORWARD REACH NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWI5TING OF THE WRIST. THE FORGE z 4 -, I I/4" - I I/2° 15 REQUIRED, AND 54" MAXIMUM WRERE ASIDE REACH 15 6 ? 4-O 15 REQUIRED, REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5LB5. THEY SHOULD 48' - -- BE MOUNTED A MAX. OF 48" A.F.F. AND A MIN, OF 15" A.F.F. B. IF THE FORWARD REACH 15 OVER AN OBSTRUCTION (WITH 2. PUBLIC, TELEPHONES: HIGHEST OPERABLE PART SHALL BE LESS THAN 48" A.F.F. a � STAINLESS STEEL HANDICAP GRAB BARS PER CODE. G.G. TO KNEE 5PAGIr EQUAL TO OR GREATER THAN REACH DISTANCE) - z NOTE. PROVIDE SOLID WOOD BAGKING FOR SECURE MOUNT. A 20"25" DEEP THE MAXIMUM HEIGHT SHALL BF -4411; IF THE `' DRINKING FOUNTAINS: HANDRAIL OR GRAB BAR AND ANY WALL OR OTHER SURFACE OBSTRUCTION 15 LE55 THAN 20", MAXIMUM HEIGHT SHALL BE ° "X" SHALL BE <= 25"; "Z" SHALL BE >_ "X". WHEN X < 20", THEN "Y" ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE 48 ADA COMPLIANT TOILET I. DRINKING FOUNTAIN'S SHALL HAVE THE CONTROLS MOUNTED ON THE FRONT SIDE NEAR 0 SHALL BE 48", MAXIMUM. NHEN "X" 15 20" To 25", THEN "Y" SHALL ELEMENTS. ED6E5 SHALL HAVE A MINIMUM RADIUS OF I/8". GRAB BE 44" MAXIMUM. BARS MUST BE ABLE TO SUPPORT A 250 POUND LOAD AND C. MAXIMUM HEIGHT SHALL BE 46" FOR SIDE REACH OVER AN 16" THE FRONT EDGE. THE SPOUT SHALL BE NO HIGHER THAN 36" A.F.F. THE SPOUT SHALL BE OBSTRUCTION 34" MAXIMUM HIGH AND 24" MAXIMUM DEEP. AT THE FRONT EDC)= AND PROVIDE A WATER FLOW AT LEAST 4" HIGH. PROVIDE A SHALL NOT ROTATE WITHIN THEIR FITTINGS. SECOND WATER FOUNTAIN MOUNTED AT STANDARD HEIGHT FOR THE PERSONS WITH BENDING PROBLEMS. CLEAR KNEE SPACE BETWEEN THE BOTTOM OF THE APRON AND MAX REACH 1/4" = I' -o" 2-8 REACH LIMITS N.T.S. 23 ACCESSIBLE GRAB BARS N.T.S.118 PUB. TEL. CLEARANCES N.T.S. 13 REAR STALL WALLS I/4" = I' -o" OS FLOOR SHALL 4 2-t"HIGH, 30" NIDE AND 17" To Iq" DEEP. PROVIDE A CLEAR FLOOR SPACE OF 30"X48" AT EACH FOUNTAIN. PULL SIDE - '�X PUSH SIDE I. OBJECTS PROJECTING eUBLIG TOILET ROOMS: Lary Le ` FROM WALLS (FOR I I - EXAMPLE TELEPHONE 4 I. ALL TOILET FIXTURES, AGGE550RIE5, DOORS AND PARTITIONS TO MEET THE ELECTRIC z AL PANELS) WITH REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. • I I WIDTH STROKE WIDTH THEIR LEADING EDGES 4 BETWEEN 2.7 IN. AND 80 IN. 2. GRAB -BARS SHALL BE 1-1/2" DIAMETER X 4.2" LONG AT SIDE OF W.G. AND 36" LONG ristian (685 MM AND 2030 MM) AT BACK OF W.G. 5TAINLF-55 STEEL MOUNTED 5UGH THAT THERE 15 I-1/2" CLEARANCE ABOVE THE FINISHED BETWEEN THE BAR AND THE WALL. THE BAR SHALL NOT ROTATE IN IT'S MOUNTING. THE 18" MIN. 24" PREFERRED FLOOR SHALL PROTRUDE 54" MIN. END OF THE BAR SHALL NOT BE MOUNTED FURTHER THAN 12" FROM THE BACK WALL OF NO MORE THAN 4 IN. (100THE TOILET STALL. PROVIDE BACKING IN THE WALL5 TO MOUNT THE GRAB BARS 5U6H AtIvAl MM) INTO WALK5, HALLS, 12 42" MIN. THAT THE BARS WILL SUPPORT 250 POUNDS. THE GRAB -BARS SHALL BE MOUNTED 33" CORRIDORS, STAINLESS STEEL ANY n15TANGE 4" MAX' PASSAGEWAYS, OR GRAB BARS PER GODS TO 36" A.F.F. SIGN AISLES. CLEAR WI►�T}I TISSUE DISPI=NSER Y 3. THE WATER OL05ET SEAT SHALL BE 17" TO 11" A.F.F. AND THE W.G. SHALL BE 3801 Kirby Dr., Suite 600 .� MOUNTED 18" FROM THE SIDE WALL To THE CENTER OF THE W.G. THE FLUSH VALVE Houston, Texas 77098 NOTE: X=12" IF DOOR HAS BOTH A Vm N2. OBJEGT5 WITH THEIR z SHALL BE A MAX. OF 44" A.F.F. AND LOCATED ON THE NIDI= SIDE OF THE ROOM OR tel: 713 664 7974 CLOSER AND A LATCH LEADING EDGE BELON 2-1 m z IN. (685 MM) ABOVE '�' IN. fax: 713 664 9756 �_ PULL SIDE LETTERS AND NUMBERS ON SIGNS SHALLFINISHED FLOOR MAY - 4. THE TOILET PAPER HOLDER SHALL BE 11" MIN. A.F.F. TOILET PAPER DISPENSERS THAT X PUSH SIDE HAVE A NIDTH-TO-HEIGHT RATIO BETNEEN < PROTRUDE ANY AMOUNT. 36" MAX CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE - - - - 3:5 AND 1.1, AND A STROKE -WIDTH -TO -HEIGHT USED. I - RATIO BETWEEN 1:5 AND 1:10. 3. PROTRUDING OBJI GT5 1 SHALL NOT REDUCE THE 5. LAVATORIES SHALL BE MOUNTED SUCH THAT THE RIM IS NO HIGHER THAN 36" AFF z �I (FOR ALL AGGE55I5LE SIGNAGE) CLEAR FLOOR WIDTH OF PROVIDE A GLEARANCE OF 21" MIN. A.F.F. TO THE BOTTOM APRON OF THE LAV., 2-1" AN ACOF-551BLE ROUTE A.F.F. MIN. TO THE BOTTOM OF THE LAY., 1" MIN. TOE SPACE BELOW THE PIPES TO BE t f 4 I I I OR MANEUVERING SPACE. INSULATED. THERE SHALL BE NO ABRASIVE SURFACES. X I _ LETTERING N.T.S. Z� PROTRUDING OBJECTS N.T.S. r2 SIDE STALL WALLS I/2" = 1'-O" o� 6. FAUCETS SHALL BE LEVER OPERATED, PUSH TYPE OR ELECTRONICALLY I CONTROLLED, SELF CLOSING VALVES SHALL BE OPEN 10 5ECOND5 MIN. FAUCETS SHALL , I' O" I,- '-O" REQUIRE A MAX. OF 5 LBS. FORGE TO OPERATE, NOTE: X-36 MINIMUM IF Y=60"; i. MIRRORS SMALL BE MOUNTED SUCH THAT THE LOWER REFLECTING SURFACE IS 40" Q.. ° A%.F.F. MAX AND THE UPPER REFLECTING SURFACE 15 74" A.F.F. MIN. X=42' MINIMUM F Y=54" 2' °"la 2" - ---- NOTE: X=12" IF DOOR HAS BOTH A 8. PAPER TOWEL DISPENSER AND WASTE D15PEN51=R OR ELECTRIC HAND DRYERS Expires: 02.28.09 CLOSER AND A LATCH SHALL BE MOUNTED SUCH THAT THE ACCESS OR CONTROL IS MOUNTED 48" A.F.F. MAX. Larry L. Christian, A.I.A. Florida Architectural Registration u., LIAR -0010755 E FULL SIDE MSN Q WOMt=N 1. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH -TO -LENGTH RATIO BETWEEN XX PUSH 51DE 4 4 l 3:5 AND I:I AND A STROKE WIDTH-TO-HEIGRT RATIO BETWEEN 1:5 AND 1:10, LETTERS 24" MIN. 24" MIN. AND NUMERALS SHALL BE RAISED I/32 IN., UPPER CASE, SANS -SERIF OR SIMPLE SERIF v ELEG. HAND DRYER SAN. SEAT DISPENSER LATCH SIDE OF � � LATCH SIDE OF '�" TYPE AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS DOOR FRAME DOOR FRAME = SHALL BE AT LEAST 5/8" HIGH, BUT NO HIGHER THAN 2". PIGTOGRAM5 5HALL BE ACCESSIBIL17Y F __T 4 3o"X48" � AGGOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW (j AGGE551BLE SIGNAGE NOTES: ADA COMPLIANT IGLEAR I Q THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6" MINIMUM ST,hNi� RAS U URINAL ,FLOOR i HEIGHT. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND AND I. SIGNAGE SHALL BE BLUE ON WHITE OR WHITE ON 'SPACE BOTH SHALL BE OF A NON -GLARE FINISH. BLUE BACKGROUND 1 / 2'-6� " MIN. 2. BAGKGROUND SHALL VISUALLY CONTRAST KITH - I NOTE: Y=54" MINIMUM IF DOOR HAS CLOSER DOOR OR WALL COLOR 3. BACKGROUND SHALL BE I/4" THICK MIN. ADAN-i 4. CHARACTERS AND SIGNAGE SHALL BE EGGSHELL, PAPER TOW)=L PAPER TOWEL/ NOTE: Y=48" MINIMUM IF Poon HAS CLOSER MATTE, OR OTHER NON -GLARE FIN15H DISPENSER NA5TE RECEPT. Date: 07.28.2008 MANEUVERING CLEARANCES AT DOORS N.T.S. 2z SIGNAGE N.T.5. 16 1 ACCESSORY HT.S N.T.5. zI URNL. CLEARANCES Fo6 ADA STANDAR NOTES N.T.S. OI ® Project No. 0805776 HVAC GENERAL NOTES GENERAL: MECHANICAL/ELECTRICAL COORDINATION: 5. ALL OPEN ENDED DUCTS AND FAN OUTLETS SHALL HAVE '%" X '/Z" HARDWARE CLOTH AFFIXED 1. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE REQUIREMENTS OFTO 1. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL THE OPENING. THE 2004 FLORIDA MECHANICAL CODE, THE 2004 FLORIDA BUILDING CODE, AMENDMENTS, NFPA 90A, 101, UNDERWRITERS LABORATORIES (OR ETL) AND ALL APPLICABLE LOCAL CODES AND MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR 6. EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL CONSTRUCTED TO SMACNA ORDINANCES. SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN STANDARDS AND SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. TOILET EXHAUST THEREIN. SHOP DRAWING SUBMITTALS SHALL CLEARLY STATE THAT THE ELECTRICAL 1.3 0.25" 2. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD CHARACTERISTICS OF ALL EQUIPMENT HAS BEEN COORDINATED WITH THE ELECTRICAL CONTRACT DOCUMENTS AND THE ELECTRICAL CONTRACTOR.S 7. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON VERIFY ALL EXISTING CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON 1,2,3,4 CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. 2. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH BE PER SMACNA STANDARDS. 3. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON-FUSED) WITH EQUIPMENT CHARACTERISTICS, 8. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M -KE (U.L. 181 LISTED, CLASS 1 FLEXIBLE AIR ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL EQUIPMENT. SHOP DRAWINGS SHALL MANUFACTURER'S RECOMMENDATIONS AND THE ELECTRICAL DRAWINGS. DUCT) OR EQUAL. PROVIDE THERMAFLEX M -KE R-6 (R VALUE - 6.0 MINIMUM OR AS REQUIRED INCLUDE: ALL EQUIPMENT SCHEDULED OR SPECIFIED ON THE DRAWINGS; DUCTWORK DRAWN TO 24x24 BY LOCAL ENERGY CODE). AIR CONNECTORS ARE NOT ACCEPTABLE, FLEX DUCT DIAMETER SHALL 1/4" SCALE OR THE SCALE SHOWN ON THE DRAWINGS; AND CONTROL WIRING SCHEMATICS 3. ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, ID E MATCH DEVICE NECK DIAMETER. PROVIDE ROUIN ND GALVANIZED STEEL DUCT RUNOUTS TO MA N MAINTAIN IAS CERTIFIED BY THE AIR CONDITIONING EQUIPMENT MANUFACTURER. DEVICES, ETC.) NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE 5ROU FLEXIBLE DUCTWORK SHALL BE INSTALLED A MAXIMUM FLEXIBLE DUCT LENGTH 4. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED ACCORDING TO CODE STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS, PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT RECOMMENDATIONS. REQUIREMENTS. TO AIR DEVICE NECK WHEN REQUIRED. 5. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE 4. UNLESS NOTED OTHERWISE, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED WITH THE EQUIPMENT IT SERVES AND INSTALLED 9. ROUND AND FLEXIBLE SUPPLY AIR DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH A YEAR AFTER ACCEPTANCE BY OWNER. BY THE MECHANICAL CONTRACTOR. MOTOR STARTERS FOR HVAC EQUIPMENT SHALL BE FURNISHED SPIN -IN FITTING WITH SCOOP AND BALANCING DAMPER 6. ALL FIVAC COMPRESSORS SHALL HAVE EXTENDED 4 -YEAR MANUFACTURER'S WARRANTY. WITH 'THE MOTOR OR APPARATUS WHICH IT OPERATES. MOTOR STARTER INSTALLATION SHALL BE BY THE DIVISION 16 CONTRACTOR. 10. LINE ALL EXPOSED SHEETMETAL DUCTWORK, RETURN AIR DUCTWORK, AND ALL SUPPLY FIRE DAMPER DUCTWORK A MINIMUM OF 10'-0" (OR AS INDICATED) DOWNSTREAM OF ALL ROOFTOP UNITS. 7. PORTIONS OF DUCTWORK AND PIPE INSULATION VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN AIRSIDE: DUCT LINER SHALL BE 1" THICK, 3 LB/FT3 DENSITY (MINIMUM R VALUE = 6.0 OR AS REQUIRED FINISHED AREAS SHALL BE PAINTED FLAT BLACK. PAINT TO HAVE A FLAME SPREAD INDEX OF 25 BY APPLICABLE ENERGY CODE); CERTAINTEED "TOUGHGARD 2" OR EQUAL BY KNAUF OR AND A SMOKE DEVELOPED INDEX OF 50. 1a. ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE SHALL BE INSTALLED JOHNS -MANVILLE. PRODUCTS BY OWENS-CORNING ARE NOT ACCEPTABLE, THE LEADING EDGE OF 8, MOUNT TOP OF "THERMOSTAT 4'-0" AFF UNLESS NOTED OTHERWISE. PROVIDE CLEAR LOCKING WITH A SMOKE DETECTOR IN THE SUPPLY DUCTWORK. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE SUPPLY AIR PATH OF AIR DISTRIBUTION SYSTEMS UTILIZING A COMMON SUPPLY THE DUCT LINER SHALL HAVE A SHEETMETAL NOSING. GUARD ASSEMBLIES FOR ALL PUBLIC AREA THERMOSTATS. COORDINATE THERMOSTAT LOCATIONS "TRADES. AND/OR SUPPLY AIR PLENUM WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM. 11. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. WITH OTHER PROVIDE INSULATED SUB -BASE FOR ALL THERMOSTATS MOUNTED ON SMOKE DETECTOR SHALL T MOSTAT WIRING TO BE ROUTED EXTERIOR WALLS. 1b. USE IF THE PROJECT DOES NOT HAVE A FIRE ALARM SYSTEM: THE SMOKE DETECTOR SHALL 12. EXTERNAL STATIC PRESSURE (ESP) DOES NOT INCLUDE COIL, CASING OR FILTER PRESSURE 9. ALL WORK SHALL BE COORDINATED AND PERFORMED WITH PRIOR APPROVAL FROM THE OWNER BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND CAUSE A VISIBLE AND AUDIBLE ALARM SIGNAL IN A NORMALLY OCCUPIED AREA. SMOKE DETECTOR TROUBLE CONDITIONS SHALL BE DROP. TO SUIT HIS OPERATING CONDITIONS. INDICATED VISUALLY OR AUDIBLY IN A NORMALLY OCCUPIED AREA AS AIR DUCT DETECTOR 13. LOCATIONS OF GRILLES, REGISTERS, & DIFFUSERS SHOWN ON THE DRAWINGS ARE 10. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE TROUBLE. THE SMOKE DETECTOR AND AUDIBLE/VISIBLE ALARM SHALL BE FURNISHED AND "THE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, ETC. AND ARCHITECTURAL REFLECTED CEILING PLAN. OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS. INSTALLED BY MECHANICAL CONTRACTOR. AUDIBLE/VISIBLE STROBE SHALL ALSO BE PROVIDED IF THERE IS A FIRE ALARM PANEL. 14. ALL EXPOSED DUCTWORK 'TO HAVE PAINT GRIP, COLOR BY ARCHITECT AND FLAME SPREAD 11. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, ANDINDEX 1c. SMOKE DETECTORS SHALL PROVIDE AUTOMATIC SHUTOFF AND BE LOCATED BEFORE ANY OF 25 AND A SMOKE DEVELOPED INDEX OF 50. BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. SUBMIT CERTIFIED (AABC BRANCH DUCTS. A VISIBLE AND AUDIBLE OR NEBB) TEST AND BALANCE REPORT TO THE ARCHITECT FOR APPROVAL. 15. CONTRACTOR MAY SUBSTITUTE ROUND DUCTWORK FOR RECTANGULAR DUCTWORK, AS LONG AS ALARM SIGNAL IN A ld. THE COST TO CONNECT TO THE LANDLORDS FIRE ALARM SYSTEM SHALL BE THE THE SIZES ARE EQUIVALENT. 12. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, CONTRACTOR'S RESPONSIBILITY. DUCTWORK, PIPING, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND J 1 lJ 1� 1� E 16. COORDINATE EXACT ROOFTOP LOCATION AND ORIENTATION. STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. 2. SUPPLY, RETURN AND O.A. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL PIPING: AS RECOMMENDED IN SMACNA DUCT CONSTRUCTION STANDARDS, LATEST EDITION. ALL JOINTS 13. ALL PIPE AND DUCT PENETRATIONS OF FIRE AND/OR SMOKE -RATED ASSEMBLIES SHALL BE AND SEAMS IN ALL SHEETMETAL DUCTWORK SHALL BE SEALED WITH DUCT SEALER. 1. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO AN FIRE -STOPPED AS REQUIRED TO RESTORE THE ASSEMBLY TO ITS ORIGINAL INTEGRITY. FIRE 3. SHEETMETAL SUPPLY DUCTWORK OVER LAY -IN CEILING AND IN NON -AIR CONDITIONED AREAS APPROVED DRAIN. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC (EXCEPT INSULATED BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY TREMCO, HILTI, 3M OR APPROVED EQUAL. AS SHALL BE INSULATED WITH 2" THICK, 3/4 LB/FT3 DENSITY FIBERGLASS BLANKET INSULATION WITH COPPER IN HVAC PLENUMS). CONDENSATE SHALL BE PUMPED AS REQUIRED. CONDENSATE SHALL RECOMMENDED BY MFG. FOR PARTICULAR APPLICATION, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS. FOIL VAPOR BARRIER, U.L. LISTED, R-6 MINIMUM. PUNCTURES AND TEARS IN THE FOIL JACKET BE RUN DOWN THROUGH RTU ROOF CURBS. SHALL BE PATCHED WITH FOIL TAPE TO MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER. LINE 2. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT 14. MANUAL OVER -RIDE CONTROL (EMERGENCY SHUT -DOWN) SWITCHES FOR ALL HVAC UNITS ALL EXPOSED DUCTWORK. REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG SHALL BE LOCATED IN LOCKING COVER ADJACENT TO FIRE ALARM ANNUNCIATOR PANEL OR OTHER 4. ALTERNATE DUCTWORK - 1" THICK FIBERGLASS DUCT BOARD (MINIMUM R-4.3 OR AS FROM THE TOP CHORDS OF THE JOISTS. LOCATION APPROVED BY LOCAL AUTHORITY HAVING JURISDICTION. REQUIRED BY APPLICABLE ENERGY CODE), WITH GLASS FABRIC REINFORCED VAPOR BARRIER, 15. ALL MECHANICAL EQUIPMENT SHALL BE LABELED WITH ASEMI-RIGID PLASTIC LAMINATE JOHNS -MANVILLE TYPE 475 OR EQUAL. FIBERGLASS DUCTWORK AND TAPING SYSTEM SHALL BE NAMEPLATE WITH 2" HIGH WHITE LETTERS ON A BLACK BACKGROUND SECURELY AFFIXED TO THE U.L.-181 LISTED AND SHALL BEAR THE U.L. LABEL. ALL FIBERGLASS DUCTWORK AND EQUIPMENT. THE NAMEPLATE SHALL SHOW THE EQUIPMENT TAG USED ON THESE DRAWINGS, ACCESSORIES SHALL BE FABRICATED BY A MANUFACTURER'S AUTHORIZED FABRICATOR, SHALL BE INSTALLED WITH THE FABRICATOR'S SUPERVISION AND ACCORDING TO MANUFACTURER'S 16. REFERENCE ARCHITECTURAL PLANS FOR ALL LANDLORD REQUIREMENTS. RECOMMENDATIONS. FIBERGLASS DUCTWORK SHALL NOT BE USED OUTDOORS. TAG I MODEL DUTY CFM I SONES E.S.P. I MOTOR SIZE I RPM I DRIVE I WEIGHT (Lb) ACCESSORIES EF -1,2 SP -A110 TOILET EXHAUST 75 1.3 0.25" FRAC HP 899 DIRECT 20 1,2,3,4 EF -3 SP -A110 MOP SINK EXHAUST 75 1.3 0.25" FRAC HP 899 DIRECT 20 1,2,3,4 ACCESSORIES: I. GRAVITY BACKDRAFT DAMPER. 2. WIRE INTO WALL SWITCH, (COORDINATE WITH ELECTRICAL) 3. REMOTE MOUNTED DISCONNECT SWITCH. 4. UNIT MOUNTED SPEED CONTROL SWITCH. SELECTIONS ARE BASED ON PRODUCTS BY GREENHECK. (NEW) DX COOLING ROOFTOP UNITS NOMINAL TOTAL MIN. MAX. MBH TAG MODEL No. TONS CFM O.A. FAN ESP TOT. CFM HP COOL RTU -1 TSCO92 7.5 3000 350 2.0 1.0 85.1 MBH HEAT SEN, KW COOL OUTPUT 65.6 27.0 UNIT WEIGHT (LBS.) 1 1120 ACCESSORIES 1,2,3,4,5,6,7,8,9,10, LOW STATIC DRIVE DESCRIPTION RTU -2 TSC092 7.5 3000 350 2.0 1.0 85.1 65.6 27.0 1 1120 1,2,3,4,5,6,7,8,9,10, LOW STATIC DRIVE SA NOTES: EF 1 EQUIPMENT NUMBER DESIGNATION - (EF -1) A. COOLING CAPACITY BASED AS ON 80 DEG. F., db/67 DEG. F., wb INDOOR ENTERING AIR "TEMPERATURE AND 95 DEC. F., db ENTERING OUTDOOR TEMP, SUPPLY OR OUTSIDE AIR DUCT OR OUTLET B. ESP DOES NOT INCLUDE COIL, CASING OR FILTER LOSSES. THERMOSTAT EF C. UNIT WEIGHT INCLUDES CURB, 5OF SMOKE DETECTOR D. RTU -1,2 SHALL HAVE A MINIMUM EER OF 10.3 SIDEWALL SUPPLY AIR GRILLE 24x24 ACCESSORIES: SEE PLANS MANUAL VOLUME DAMPER 1. 14" HIGH INSULATED ROOF CURB BY UNIT MANUFACTURER. 6. BAROMETRIC RELIEF DAMPER. ROOFTOP UNIT 2. 7 DAY (_STAND-ALONE PROGRAMMABLE THERMOSTAT 7. SINGLE POINT POWER CONNECTION W/ UNIT MOUNTED DISCONNECT. WITH AUTO CHANGEOVER. OPPOSED BLADE DAMPER 8. DISCHARGE AND RETURN FLEX CONNECTIONS. 3. SMOKE DETECTOR IN RETURN AIR DUCT. CONDENSATE DRAIN 9. BELT DRIVE. 0-100% MOTORIZED OUTDOOR AIR DAMPER AND DRY BULB ECONOMIZER, WIRE MESH SCREEN 5. INTEGRAL FILTER RACK WITH 1" THICK DISPOSABLE FILTERS. 10_ MINIMUM OF 2 STAGES OF ELECTRIC HEAT. TXR SELECTIONS ARE BASED ON PRODUCTS BY TRANS NIC NOT IN CONTRACT LEGEND MARK DESCRIPTION MARK DESCRIPTION Q DIFFUSER TYPE "A" BALANCED FOR 100 CFM OA OUTSIDE AIR RA RETURN AIR 14x12 DUCT SIZE (RECTANGULAR) 0 RETURN OR EXHAUST DUCT OR OUTLET 8"0 DUCT SIZE (ROUND) SA SUPPLY AIR EF 1 EQUIPMENT NUMBER DESIGNATION - (EF -1) N SUPPLY OR OUTSIDE AIR DUCT OR OUTLET ® THERMOSTAT EF EXHAUST FAN 5OF SMOKE DETECTOR ALUMINUM SIDEWALL SUPPLY AIR GRILLE 24x24 CEILING DIFFUSER SEE PLANS MANUAL VOLUME DAMPER RTU ROOFTOP UNIT OBD OPPOSED BLADE DAMPER CD CONDENSATE DRAIN WMS WIRE MESH SCREEN EGGCRATE CONNECT NEW TO EXISTING TXR TRANSFER NIC NOT IN CONTRACT OED OPEN END DUCT RCP REFLECTED CEILING PLAN - FD FIRE DAMPER 12x12 DIFFUSER TO BE PROVIDED WITH 2424 LAY -IN PANEL, IF SHOWN ON PLANS. GRILLES, REGISTERS, & DIFFUSERS TAG SERIES DUTY MATERIAL DAMPER NOM. FACE SIZE CFM NECK (IN. DIAM,) TYPE / NOTES A TMS SUPPLY STEEL YES 2424 SEE PLANS SEE PLANS MULTI -LOUVERED DIFFUSER STANDARD COMMERCIAL TYPE B TMS SUPPLY STEEL YES 12x12 SEE PLANS SEE PLANS C 5OF RETURN ALUMINUM NO 24x24 SEE PLANS SEE PLANS EGGCRATE - D 15OF I TRANSFER I ALUMINUM NO 2424 SEE PLANS SEE PLANS EGGCRATE NOTES: 4--) A. REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF CEILING AND/OR SUSPENSION SYSTEM. B. COLOR SHALL BE BY ARCHITECT, SUBMIT COLOR CHART FOR APPROVAL. POWER WIRING PROVIDE DAMPER INTEGRAL WITH DIFFUSER AS WELL AS AT TAKE -OFF. 12x12 DIFFUSER TO BE PROVIDED WITH 2424 LAY -IN PANEL, IF SHOWN ON PLANS. SELECTIONS ARE BASED ON PRODUCTS BY TITUS. (SEE ELECTRICAL) HVAC DEMOLITION NOTES - A. CONTRACTOR SHALL VISIT THE SITE AND CAREFULLY EXAMINE EXISTING CONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE MADE . FOR LACK OF KNOWLEDGE OF EXISTING CONDITIONS. B. FURNISH ALL LABOR, EQUIPMENT, MATERIALS AND INCIDENTALS REQUIRED 'TO REMOVE ALL EXISTING EQUIPMENT AND ALL PIPE, FITTINGS, VALVES ANDE APPURT NANCES AS REQUIRED FOR Q THE PROPER OPERATION OF THE NEW PLUMBING, HEATING, N VENTILATING AIR CONDITIONING SYSTEM. REMOVAL WILL BE CONSISTENT WITH THE FINAL CONFIGURATION OF THE NEW SYSTEMS AS INDICATED, AS D SPECIFIED HEREIN, OR AS REQUIRED BY THE ARCHITECT. THE EQUIPMENT AND DUCTWORK THAT IS DEMOLISHED SHALL BE REMOVED FROM THEIR PRESENT LOCATIONS AND SHALL BE REMOVED FROM THE SITE AS SPECIFIED HEREINAFTER. C. N SHOULD BE NOTED THAT SOME HVAC SYSTEMS ARE TO REMAIN. IF ANY OF THESE SYSTEMS ARE DAMAGED DURING THE PROGRESS OF CONSTRUCTION OR DEMOLITION, THEY SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE ARCHITECT WITHOUT INCURRING ADDITIONS TO THE CONTRACT. D. UNLESS SPECIFICALLY NOTED TO BE REMOVED, EXISTING EQUIPMENT, CONDENSATE PIPING, DUCTWORK, ETC. IS TO REMAIN. ANY EQUIPMENT, PIPING OR APPURTENANCES REMOVED WHICH ARE NECESSARY FOR THE OPERATION OF THE EXISTING SYSTEM SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT WITHOUT INCURRING ADDITIONS TO THE CONTRACT. E. ALL EXISTING TUBING, INSULATION, HANGERS AND SUPPORTS THAT ARE DEMOLISHED SHALL BECOME THE PROPERTY OF THE CONTRACTOR UPON REMOVAL FROM THEIR PRESENT LOCATIONS. THE MATERIAL SHALL BE REMOVED IMMEDIATELY FROM THE SITE AND IT SHALL NOT BE REUSED, F. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AGAINST DAMAGING THE MATERIAL AND EQUIPMENT TO BE STORED. THE CONTRACTOR SHALL REPAIR ALL DAMAGE RESULTING FROM HIS OPERATIONS, AS DIRECTED BY AND TO THE SATISFACTION OF THE ARCHITECT, ITEMIZED LISTS OF MATERIALS REMOVED AND STORED SHALL BE RECORDED AND SUBMITTED TO THE OWNER AT THE COMPLETION OF CONSTRUCTION. THE LIST SHALL INCLUDE ITEMS, HOW PACKAGED AND PLACE STORED. G. PERFORM ALL WORK REQUIRED TO TIE-IN NEW WORK TO EXISTING WORK AND TO ADAPT EXISTING WORK TO CHANGES IN THE BUILDING AND THE PLUMBING, HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS. H. WHERE PIPES, CONTROL DEVICES AND WIRING WHICH ARE TO REMAIN IN SERVICE ARE DISCONNECTED FOR THE REMOVAL OR RELOCATION OF EQUIPMENT OR BECAUSE OF BUILDING ALTERATIONS, THEY SHALL BE RECONNECTED. I. SEAL ALL PENETRATIONS MADE AS A RESULT OF DUCTWORK AND PIPING DEMOLITION TO MATCH EXISTING. J. COORDINATE ALL NEW EQUIPMENT AND DUCTWORK LOCATIONS WITH STRUCTURAL PRIOR TO START OF NEW WORK. K. DEMOLISH ALL LOW PRESSURE DUCTWORK ASSOCIATED WITH EXISTING RTU BACK TO RISERS AND PREPARE FOR RECONNECTION TO NEW. VENTILATION AIR CALCULATIONS NET CODE REQUIRED MINIMUM SPACE SQUARE FEET CFM/SF CFM REQUIRED CFM PROVIDED SALES 2308 SF 0.3 695 700 NOTES: 1. SALES AREA SQUARE FOOTAGE INCLUDES FILES/RECORDS ROOM. 2. EACH TOILET ROOM SHALL HAVE A 75 CFM EXHAUST FAN TO MEET EXHAUST REQUIREMENTS, 3. NET SQUARE FOOTAGE DOES NOT INCLUDE DISPLAY AREA OR BEDS WHICH ARE NOT OCCUPIABLE SPACES. &E3 ac_ (TYP. 4) Floor Play. NOTE (APPLIES TO THIS SHEET ONLY) CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING AND START OF CONSTRUCTION AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS OR DISCREPANCIES WITH THE DRAWINGS. ANY REQUIRED MODIFICATIONS NOT IDENTIFIED UNTIL START OF CONSTRUCTION SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. ROOFTOP UNIT 1/4" MASON OR AMBER BOOTH SEISMIC RESTRAINT CABLE. LACE THROUGH LIFTING LUG OPENINGS AT CORNER OF UNIT. ONE CABLE REQUIRED AT EACH OF THE FOUR CORNERS. - MASON OR AMBER BOOTH S.S. U=BOLT CABLE CLIPS S.S. EYE -BOLT THRU CURB WATERPROOF PENETRATION WITH 20 YEAR SILICONE CAULK 16"H CURB (MIN.) ROOFING/FLASHING BY GENERAL CONTRACTOR- NEW ONTRACTOR- NEW CURB FRAMING EXISTING ROOF STRC GENERAL NOTE (APPLIES TO THIS SHEET ONLY) 1. CONTRACTOR TO COORDINATE EXACT T -STAT LOCATIONS WITH OWNER. 2. CONTRACTOR TO ROUTE SUPPLY DUCTS TIGHT TO DECK. 3/4" x 1/4" WIDE (FOAM OR NEOPRENE) GASKET AROUND ENTIRE CURB FRAME NUT TACK WELDED TO STRUCTURAL ANGLE Vib" =I' -o" OI -1 ALTERNATE (APPLIES TO THIS SHEET ONLY) CONTRACTOR IS ALLOWED TO PROVIDE ALTERNATE BID FOR SNAP LOCK DUCTWORK AND FIBER GLASS DUCT BOARD AS AN ALTERNATE TO SPECIFIED DUCTWORK. CONDENSER FAN DISCHARGE DISCONNECT (SEE \ ELECTRICAL DWGS.) -� OUTDOOR AIR INTAKE--/ YVUMtN 104 I Revisions No. Date Description �0-7,222008 LL COMMENTS I j \UST DUCT ROOF TO THESE DOCUMENTS HAVE BEEN PREPARED _LAR, & SPECIFICALLY FOR THE FOLLOWING PROJECT. Interior Tenant Improvements for: Mattress Firm Seminole *Town Center WP Ball & Town Center Blvd, Sanford, Florida 32771 THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT, REPRODUCTION IS PROHIBITED, COPYRIGHT 2008 LARRY L. CHRISTIAN, A.L.A. BAROMETRIC RELIEF HOOD CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON "TIES. INTERIOR LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. INSTALL USING TENSIONING TOOL AS PER MANUFACTURER'S RECOMMENDATIONS. — ROUND SHEET METAL DUCT. DIAMETER AS INDICATED ON PLANS. NYLON TIES ® ` NOTE: SEAL INTERIOR LINER OF FLEX DUCT WITH MASTIC AT CONNECTION TO METAL DUCTWORK AND DIFFUSERS. IL INTERIOR LINER PREINSULATED FLEXIBLE DUCTWORK, SEE SPECIFICATIONS. LENGTH NOT TO EXCEED 5'-0". PROVIDE SUPPORT PER SMACNA STANDARDS, INSTALL FREE OF ! I i KINKS & SAGS, INSIDE LINER AND EXTE!I;�fli!!>i.,. SHALL( BE FACE FLEX DUCTWORK MANUAL BALANCING DAMPER WITH LOCKING QUADRANT. TRUNK DUCT-' CONICAL SPIN -IN FITTING - WITH DAMPER & SCOOP SUPPLY DIFFUSER SEE ARCH. PLANS WITH DAMPER FOR E. FLEXIBLE DUCT TAKE --OFF DETAIL SCHEMATIC - NO SCALE ROOF TOP AIR CONDITIONER DETAIL SCHEMATIC - NO SCALE I' VID QJ PREFABRICATED 2' x 2 x 1/4 ANGLE IN ROOF CURBI I I 1 ROOF DECK CORNER OF CURB. THIS ANGLE IS WELDED TO ETA 4--) THE ROOF STRUCTURE POWER WIRING AND/OR CURB FRAMING. (SEE ELECTRICAL) PROVIDE WIND RESISTANT CONDENSATE DRAIN CONNECTION FOR ROOFTOP SMOKE DETECTOR SHALL T MOSTAT WIRING TO BE ROUTED ® UNIT. BE WIRED TO STOP THE PER PLANS JL FAN UPON DETECTION TRAP OF SMOKE, AND CAUSE A VISIBLE AND AUDIBLE SUPPLY AIR DUCT - RETURN AIR DUCT ALARM SIGNAL IN A n �T ROOFTOP UNIT T RRICAj` HURRICANE LY OCCUPIED J 1 lJ 1� 1� E AREA. NOTE: ALL CONNECTIONS AND SERVICES MUST BE INSIDE THE PERIMETER CURB. TIE -DOWN DETAIL DISCONNECT SWITCHES, BRACKETS, AND CONDUIT MUST BE CLEAR OF ALL UNIT PANELS AND AIR FLOW. BRACKETS MUST BE TO STRUCTURAL MEMBERS OF UNIT. SCHEMATIC - NO SCALE CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON "TIES. INTERIOR LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. INSTALL USING TENSIONING TOOL AS PER MANUFACTURER'S RECOMMENDATIONS. — ROUND SHEET METAL DUCT. DIAMETER AS INDICATED ON PLANS. NYLON TIES ® ` NOTE: SEAL INTERIOR LINER OF FLEX DUCT WITH MASTIC AT CONNECTION TO METAL DUCTWORK AND DIFFUSERS. IL INTERIOR LINER PREINSULATED FLEXIBLE DUCTWORK, SEE SPECIFICATIONS. LENGTH NOT TO EXCEED 5'-0". PROVIDE SUPPORT PER SMACNA STANDARDS, INSTALL FREE OF ! I i KINKS & SAGS, INSIDE LINER AND EXTE!I;�fli!!>i.,. SHALL( BE FACE FLEX DUCTWORK MANUAL BALANCING DAMPER WITH LOCKING QUADRANT. TRUNK DUCT-' CONICAL SPIN -IN FITTING - WITH DAMPER & SCOOP SUPPLY DIFFUSER SEE ARCH. PLANS WITH DAMPER FOR E. FLEXIBLE DUCT TAKE --OFF DETAIL SCHEMATIC - NO SCALE ROOF TOP AIR CONDITIONER DETAIL SCHEMATIC - NO SCALE N ® N Darr L e ristian A*19A$ 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 JIIIIIIIIIII LErvEND, 5GHEDULE, AND FLOOR PLAN Florida Department of (Business & Professional Regulation - MECHANICAL License Number 4711 o Expires 28 February 2009 Jordan & Skala Engineers, Inc. M-1 Project Number " 086.0363 11231 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 PHONE (281)617-3200 FAX (281)617-3207 Date: .06-19-2008 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. Project No. 0805-776 NORTH VID QJ ETA 4--) [C ® L 1 N ® N Darr L e ristian A*19A$ 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 JIIIIIIIIIII LErvEND, 5GHEDULE, AND FLOOR PLAN Florida Department of (Business & Professional Regulation - MECHANICAL License Number 4711 o Expires 28 February 2009 Jordan & Skala Engineers, Inc. M-1 Project Number " 086.0363 11231 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 PHONE (281)617-3200 FAX (281)617-3207 Date: .06-19-2008 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. Project No. 0805-776 NORTH ELECTRICAL SPECIFICATIONS ......AMPERE ......ABOVE GEN ......GENERATOR GFCI/GFI...... GROUND NL I. SCOPE ......ALTERNATING CURRENT CRC 71 NO INSTALL ALL ELECTRICAL WORK COVERED BY THE BELOW SPECIFICATIONS AND APPROVED DRAWINGS. PROVIDE ALL MATERIAL, LABOR, TRANSPORTATION, TOOLS, 2. TYPE MC CABLE MAY BE USED FOR BRANCH CIRCUIT WIRING WITH CONDUCTOR E. PANELBOARDS ......GALVANIZED GND......GROUND SUPERVISION, ETC., NECESSARY TO COMPLETE THE TOTAL ELECTRICAL JOB. ALL ..NOT TO SCALE SIZES #8 OR SMALLER. ALL MC CABLE SHALL CONTAIN A FULL SIZE GREEN INSULATED GROUND WIRE. MC ......AMPERE INTERRUPTING CAPACITY HT ITEMS NOT SPECIFICALLY MENTIONED HEREIN WHICH ARE OBVIOUSLY NECESSARY TO PNL CABLE SHALL NOT BE USED FOR HOMERUNS. 1. SHALL BE SPECIFIED ON THE DRAWINGS. ......ALUMINUM ......AUTOMATIC TRANSFER SWITCH MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR, INCLUDING ANY NECESSARY FIELD ENGINEERING AND/OR DETAIL DRAWINGS REQUIRED. 3. LIQUIDTIGHT FLEXIBLE METAL OR NON-METALLIC CONDUIT SHALL BE 2. SHALL BE BOLT -IN CIRCUIT BREAKER TYPE AWG DRAWINGS SHALL BE SUBMITTED FOR APPROVAL AS PROVIDED FOR IN "SHOP HOA USED FROM OUTDOOR EXPOSED CONNECTIONS TO GROUND- OR ROOF- MOUNTED EQUIPMENT (MOTORS, TRANSFORMERS, ETC.) AND WITH A lU0% RATED MAIN BREAKER OR RATED MAIN LUGS ONLY AS NOTED ON DRAWINGS. ALL WI ......REMOTE CONTROL DRAWINGS". .....BREAKER SHALL COMPLY WITH ARTICLES 350 AND 356 OF THE NATIONAL ELECTRICAL CODE, SHALL HAVE U.L. APPROVED INTERRUPTING CAPACITY 22,000 AMPS 1I. CODES AND FEES C CB ......CONDUIT BREAKER MINIMUM UNLESS INDICATED ON DRAWINGS (RMS SYMMETRICAL AMPERES ......HERTZ ......ISOLATED GROUND REF RMS 4. RIGID NONMETALLIC CONDUIT SHALL. BE PVC SCHEDULE 40 AND SHALL AT VOLTAGE INDICATED ON DRAWINGS). ALL BUSSING SHALL BE COPPER. ISO JB ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST SYS COMPLY WITH ARTICLE 352 OF THE NATIONAL ELECTRICAL CODE. RIGID NON-METALLIC CONDUIT MAY BE USED FOR SERVICE 3. SIDE AND GUTTERS SHALL HAVE MINIMUM CODE CLEARANCES. DEPTH ......CIRCUIT EDITION OF THE NATIONAL ELECTRICAL CODE, NEPA 70, NATIONAL ELECTRICAL SAFETY CODE, ANSI C-2 AND ALL LOCAL ......JUNCTION ...KILO, THOUSAND ENTRANCE, IF ALLOWED BY LOCAL CODE AUTHORITY AND INSTALLED PER THE SHALL BE 5 3/4" MINIMUM. CPU AND STATE CODES AND REGULATIONS, THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED KCMIL LED NATIONAL ELECTRICAL CODE. 4. APPROVED MANUFACTURERS ARE: SQUARE D, GENERAL ELECTRIC, ......TERMINAL BOX BY THE BUILDING AND SAFETY CODES AND ORDINANCES, AND THE RULES AND REGULATIONS OF ANY LEGAL BODY HAVING JURISDICTION. 5. ALL RACEWAYS SHALL BE INSTALLED CONCEALED EXCEPT IN SIEMENS, AND CUTLER -HAMMER. TEL ......TELEPHONE CT DC UNFINISHED SPACES OR WHERE INDICATED. -TYPEWRITTEN III. WORKMANSHIP .TELEVISION DN 5. DIRECTORIES AND PANELBOARD DESIGNATION PLATES MCB ......MAIN CIRCUIT BREAKER UG ......TYPICAL ......UNDERGROUND SHALL BE PROVIDED BY THE CONTRACTOR FOR ALL PANELBOARDS. ......DOWN ......EMERGENCY ALL WORK SHALL BE NEATLY, ORDERLY AND SECURELY INSTALLED WITH CONDUITS, C. CONDUCTORS F. LIGHTING FIXTURES ......UNDERWRITERS LABORATORIES PANELS, BOXES, SWITCHES, ETC., PERPENDICULAR AND/OR PARALLEL WITH THE ......EXISTING TO REMAIN MLO ......MOUNTING HEIGHT LUGS ONLY UNO PRINCIPAL STRUCTURAL MEMBERS, AND SHALL BE LEFT IN PROPER WORKING ORDER. THE DRAWINGS ARE 1. ALL CONDUCTORS SHALL BE COPPER AND HAVE 600 VOLT TYPE THHN/THWN, 90 C INSULATION EXCEPT WHERE NOTED ON 1. UNLESS INDICATED ON DRAWINGS, BALLASTS PROVIDED WITH FIXTURES ......MAIN DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT. COORDINATE DEVICE LOCATIONS WITH DOOR SWINGS, ......UNINTERRUPTED POWER SUPPLY THE DRAWINGS. SHALL BE ETL-CBM APPROVED, HIGH POWER FACTOR, WITH U.L. LABEL. ALL MTG NC CABINETS, COUNTERS, ETC., AS INDICATED ON THE ARCHITECTURAL DRAWINGS. DO 2. ALL BRANCH CIRCUITS SHALL BE MINIMUM OF #12 AWG SOLID COPPER BALLASTS FOR RAPID START LAMPS SHALL BE PREMIUM CLASS P. BALLASTS SHALL BE FOR THE 'TO FEEDER NOT SCALE ELECTRICAL PLANS, OBTAIN DIMENSIONS FOR LAYOUT OF EQUIPMENT ......NORMALLY CLOSED EXCEPT FOR MOTOR LEADS, WHICH SHALL BE A MINIMUM OF #12 AWG STRANDED VOLTAGE OF THE CIRCUIT WHICH CONNECTED. BALLASTS SHALL BE PROVIDED FOR ALL FLUORESCENT AND FL FROM ARCHITECTURAL PLANS UNLESS INDICATED ON ELECTRICAL PLANS. FIRE ALARM HORN/SPEAKER (NOTE L-3) COPPER, UNLESS OTHERWISE NOTED ON DRAWINGS. HIGH INTENSITY DISCHARGE LAMPS. EACH BALLAST SHALL BE 1V. SUBSTITUTIONS 3. ALL BRANCH CIRCUIT AND FEEDER CONDUCTORS, N0. 8 AWG AND PROTECTED BY AN INTERNAL FAST BLOWING FUSE. CONTRACTOR TO XFMR XP .......TRANSFORMER ......EXPLOSION PROOF SMALLER, SHALL BE COLOR CODED AS FOLLOWS: PROVIDE PROPER FUSES. ......NOT IN CONTRACT ALL COST INCURRED BY THE ACCEPTANCE OF SUBSTITUTIONS SHALL BE BORNE BY THE1`LO/208 CONTRACTOR, PROOF FOR THE EQUALITY OF SUBSTITUTIONS SHALL BE BY ......WYE VOLT SYSTEM 277/480 VOLT SYSTEM 2• LAMPS SHALL BE PROVIDED FOR ALL FIXTURES IN ACCORDANCE WITH DUCT MOUNTED SMOKE DETECTOR THE CONTRACTOR. Z ......IMPEDANCE FIXTURE SCHEDULE, U-0/_U22F FIRE ALARM CONTROL PANEL, SURFACE/RECESSED PHASE A - BLACK PHASE A - BROWN FIRE ALARM ANNUNCIATOR PANEL, RECESSED V. U.L. APPROVAL TELEPHONE OUTLET, WALL MOUNTED/ABOVE COUNTER (NOTES L-1, L-2)/FLOOR MOUNTED PHASE B - RED PHASE B - ORANGE G. WIRING DEVICES COMBINATION TELEPHONE/DATA OUTLET, WALL MOUNTED/ABOVE COUNTER (NOTE L-1, L-2)/FLOOR A18"/43'?V/VVF- 0/$/ a PHASE C - BLUE PHASE C - YELLOW 18"/43" ALL ELECTRICAL ITEMS COVERED BY THIS SPECIFICATION SHALL BE U.L. LABELED NEUTRAL - WHITE NEUTRAL GREY 1. RECEPTACLES AND WALL SWITCHES SHALL BE OF THE TYPE AND SIZE AND LISTED FOR THEIR SPECIFIC USE. GROUND - GREEN GROUND - GREEN INDICATED; BY LEVITON, HUBBELL, P&S, OR ARROW HART. ISOLATED VI. ELECTRICAL SERVICE GROUND -GREEN WITH YELLOW STRIPE (WHERE APPLICABLE) a. ALL SWITCHES SHALL BE 20 AMP 120 VOLT SPECIFICATION GRADE WITH WHITE PADDLES (DECORA STYLE) UNLESS OTHERWISE A. ELECTRICAL SERVICE SHALL BE AS INDICATED ON THE DRAWINGS. SERVICE VERIFY COLOR CODING WITH LOCAL CODE AUTHORITY AND USE LOCAL NOTED. NUMBER OF POLES SHALL BE AS INDICATED ON DRAWINGS. SHALL ORIGINATE AS SHOWN ON THE DRAWINGS. CODE REQUIREMENTS IF AND ONLY IF THE ABOVE COLOR CODE IS NOT ACCEPTABLE TO LOCAL AUTHORITY. b. DUPLEX OUTLETS SHALL BE 20 AMP 125 VOLT A.C. 3 -WIRE B. SERVICE CONNECTIONS AT SERVICE POINT SHALL BE MADE BY THE LOCAL SPECIFICATION GRADE STRAIGHT BLADE WITH WHITE FACE, UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL PAY ALL COST 4. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE CONNECTED AS INDICATED UNLESS OTHERWISE NOTED ON DRAWINGS. REQUIRED BY THE LOCAL UTILITY COMPANY PROVIDING SERVICES INDICATED. ON THE DRAWINGS. COMMON NEUTRALS AND GROUND WIRES MAY BE ELECTRICAL CONTRACTOR SHALL COORDINATE METERING, TRANSFORMER PAD, PULLED IN CONDUITS WHERE ONLY OPPOSITE PHASE CONDUCTORS ARE 2. DEVICE PLATES SHALL BE WHITE COLORED AND SHALL BE PLASTIC CONNECTION POINTS AND GROUNDING WITH UTILITY COMPANY. RUN. ALL CONDUITS SHALL HAVE A GROUND WIRE PULLED AND SHALL (UNLESS OTHERWISE NOTED ON DRAWINGS). COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. C. THE MAIN DISCONNECT AND PANEL SHALL BE LABELED FOR SERVICE ENTRANCE 3. ISOLATED GROUND (IG) DEVICES SHALL HAVE SMALL ORANGE TRIANGLE EQUIPMENT. 5. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 6 AWG AND LARGER ON FACE OF DEVICE WITH PRIMARY COLOR TO MATCH OTHER, NON -IG SHALL BE PHASE IDENTIFIED IN EACH ACCESSIBLE ENCLOSURE BY ONE DEVICES. LEVITON 5362 IG W (WHITE), OR EQUAL, V11. TEST INCH WIDE PLASTIC TAPE ATTACHED TO CONDUCTORS IN A READILY VISIBLE LOCATION. TAPE COLORS SHALL MATCH COLOR CODE 4. VERIFY COLOR OF DEVICES WITH ARCHITECT A. UPON COMPLETION OF THE WORK, A TEST OF THE INDIVIDUAL SYSTEMS REQUIREMENTS SPECIFIED HEREIN. INCLUDING ALL FEEDERS, BRANCHES, OUTLETS, LIGHTING, MOTORS, APPARATUS 5. TIME CLOCK SHALL BE PARAGON EL72 OR EQUAL, AND APPLIANCES SHALL BE PERFORMED TO ASSURE OPERATION IN COMPLIANCE 6. CONNECTIONS BETWEEN FIXTURE JUNCTION BOX AND FIXTURE SHALL BE WITH THESE SPECIFICATIONS AND THE DRAWINGS. A LETTER WITH ALL MADE WITH NO 16. AWG SILICONE RUBBER INSULATED STRANDED H. DISCONNECT SWITCHES PERTINENT TEST DATA SHALL BE SUBMITTED TO THE ARCHITECT AT LEAST FIXTURE WIRE, TYPE SFF - 2 (15UB OR NO. 16 AWG (5) FIVE DAYS PRIOR TO COMPLETION OF PROJECT. THERMOPLASTIC, NYLON JACKETED STRANDED FIXTURE WIRE, TYPE THHN 1. DISCONNECT SWITCHES SHALL BE A MINIMUM OF 30 AMP, 250 VOLT (90°C) COLOR CODE AS SPECIFIED HEREIN SHALL NOT BE REQUIRED RATED, HEAVY DUTY TYPE, 3 POLE WITH SOLID NEUTRAL, UNLESS B. CONTRACTOR SHALL PROVIDE ALL INSTRUMENTS, LABOR AND MATERIALS FOR FOR FIXTURE WIRE; HOWEVER, NEUTRAL AND GROUND CONDUCTOR SHALL OTHERWISE NOTED. ANY ESSENTIAL INTERMEDIATE AND FINAL TESTS TO PROVIDE COMPLIANCE BE IDENTIFIED DISTINCTLY FROM PHASE CONDUCTORS AS PER THE WITH THESE SPECIFICATIONS. ABOVE SPECIFICATIONS. 1. FIRE ALARM SYSTEM (ALTERNATE BID) VIII. GUARANTEE 7. SPLICES IN CONDUCTORS SHALL BE MADE ONLY WITHIN JUNCTION 1. PROVIDE FIRE ALARM DETECTION, ANNUNCIATION, MONITORING, AND REPORTING BOXES, WIRING TROUGHS, AND OTHER ENCLOSURES AS PERMITTED BY SYSTEM AS REQUIRED BY GOVERNING CODES AND LOCAL AHJ. PROVIDE WORK SHALL BE GUARANTEED FOR A ONE (1) YEAR PERIOD. THE NATIONAL ELECTRICAL CODE, DO NOT SPLICE CONDUCTORS IN NOTIFIER SFP-2404, SIMPLEX 4004, OR APPROVED EQUAL BY CERBERUS/ PANELBOARDS, SAFETY SWITCHES, OR MOTOR CONTROL ENCLOSURES. PYROTRONICS, EDWARDS, OR SILENT KNIGHT. IX. SPECIFICATIONS SPLICES IN CONDUCTORS NO. 10 AWG OR SMALLER SHALL BE MADE WITH SKOTCHLOK INSULATED SPRING CONNECTORS, IDEAL WRAPPING 2. PROVIDE ALL DEVICES, WIRING, HARDWARE, ETC.. REQUIRED FOR A COMPLETE A. GROUNDING INSULATED CAPS. SPLICES IN CONDUCTORS NO. 8 AWG AND LARGER AND OPERATIONAL SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO SHALL BE MADE WITH SPLIT BOLT CONNECTORS TAPED WITH NO. 88 "TAPE SMOKE DETECTORS, HEAT DETECTORS, MANUAL PULL STATIONS, 1. SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE PLASTIC ELECTRICAL UNLESS SPLICES ARE SPECIFICALLY AND AUDIBLE/VISIBLE DEVICES. AND ALL STATE AND LOCAL CODES AND REQUIREMENTS OF THE UTILITY INDICATED TO BE MADE WITH CRIMPING SLEEVE APPLIED TO COMPANY PROVIDING SERVICE AND SHALL BE PROVIDED AS PER THESE CONDUCTORS WITH HYDRAULICALLY OPERATED CRIMPING TOOL. SPECIFICATIONS AND THE DRAWINGS. 8. UTILIZE NO. 10 AWG CONDUCTORS (MINIMUM) FOR 120 VOLT, 20 AMP 2. THE BUILDING ELECTRICAL SYSTEMS SHALL BE SOLIDLY GROUNDED BRANCH CIRCUITS LONGER THAN 75 FEET FROM BRANCH CIRCUIT PANEL SUPPLEMENTED WITH EQUIPMENT CONDUCTORS. ALL CONDUCTIVE, TO FARTHEST DEVICE OR FIXTURE. NON-CURRENT CARRYING PARTS OF THE ELECTRICAL SYSTEM (RACEWAYS, EQUIPMENT ENCLOSURES, FRAMES, JUNCTION AND OUTLET BOXES AND 9. UTILIZE NO. 10 AWG CONDUCTORS (MINIMUM) FOR 277 VOLT, 20 AMP OTHER CONDUCTIVE ITEMS IN CLOSE PROXIMITY WITH ELECTRICAL BRANCH CIRCUITS LONGER THAN 150 FEET FROM BRANCH CIRCUIT PANEL CIRCUITS) SHALL BE GROUNDED TO PROVIDE A LOW IMPEDANCE PATH TO FARTHEST DEVICE OR FIXTURE. FOR POTENTIAL GROUND FAULTS. D. JUNCTION BOXES 3. BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTORS ARE NOT SHOWN ON THE DRAWINGS, HOWEVER, AN EQUIPMENT GROUNDING CONDUCTOR SHALL ALL JUNCTION BOXES SHALL BE CONSTRUCTED OF CODE GAUGE GALVANIZED SHEET BE INSTALLED IN ALL RACEWAYS AND CABLES. STEEL AND SHALL COMPLY WITH ARTICLE 370 OF THE NATIONAL ELECTRICAL CODE, FOR THE NUMBER, SIZE AND POSITION OF CONDUITS ENTERING THE BOX, B. RACEWAYS SIZE OF BOX AND MAXIMUM NUMBER OF CONDUCTORS IN A BOX. 1. ALL RACEWAYS (UNLESS NOTED HEREIN) SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SHALL BE FERROUS GALVANIZED CONDUIT AND SHALL COMPLY WITH ARTICLE 358 OF THE NATIONAL ELECTRICAL CODE OR BE INTERMEDIATE METAL CONDUIT (IMC) AND SHALL BE FERROUS GALVANIZED CONDUIT AND SHALL COMPLY WITH ARTICLE 342 OF THE NATIONAL ELECTRICAL CODE OR BE RIGID STEEL CONDUIT AND SHALL COMPLY WITH ARTICLE 344 OF THE NATIONAL ELECTRICAL CODE. EMT COUPLINGS SHALL BE STEEL SET -SCREW TYPE. ELECTRICAL .ABBREVIATIONS A ABV ......AMPERE ......ABOVE GEN ......GENERATOR GFCI/GFI...... GROUND NL ......NIGHT LIGHT AC ......ALTERNATING CURRENT CRC FAULT CIRCUIT INTERRUPTER RIGID STEEL CONDUIT NO ......NORMALLY OPEN AFF ......ABOVE FINISHED FLOOR G OR ......GALVANIZED GND......GROUND NTS P ..NOT TO SCALE AIC ......AMPERE INTERRUPTING CAPACITY HT ......HEIGHT PNL POLE AL ATS ......ALUMINUM ......AUTOMATIC TRANSFER SWITCH HID HP ......HIGH INTENSITY DISCHARGE PVC ......PANELBOARD .....POLYVINYL CHLORIDE AWG ......AMERICAN WIRE GAUGE HOA ......HORSEPOWER -OFF -AUTOMATIC RC ......REMOTE CONTROL BKR .....BREAKER HZ ......HAND RECPT ......RECEPTACLE C CB ......CONDUIT BREAKER IG ......HERTZ ......ISOLATED GROUND REF RMS REFERENCE ......ROOT MEAN SQUARE CCTV ......CIRCUIT ......CLOSED CIRCUIT -TELEVISION ISO JB ......ISOLATED BOX SYS ......SYMMETRICAL CKT CLC ......CIRCUIT K ......JUNCTION ...KILO, THOUSAND SW SWBD ......SWITCH ......SWITCHBOARD CPU ......CEILING ......CENTRAL PROCESSING UNIT KCMIL LED ......"THOUSAND CIRCULAR MILS EMITTING DIODE TB ......TERMINAL BOX CU ......COPPER M ......LIGHT TEL ......TELEPHONE CT DC ......CURRENT TRANSFORMER MATV ......MOTOR ......MASTER ANTENNA TELEVISION TV TYP .TELEVISION DN ......DIRECT CURRENT MCB ......MAIN CIRCUIT BREAKER UG ......TYPICAL ......UNDERGROUND E ......DOWN ......EMERGENCY MCC MH ......MOTOR CONTROL CENTER UL ......UNDERWRITERS LABORATORIES ER ......EXISTING TO REMAIN MLO ......MOUNTING HEIGHT LUGS ONLY UNO UNLESS NOTED OTHERWISE EX ......EXISTING MT ......MAIN UPS ......UNINTERRUPTED POWER SUPPLY FA FACP ......FIRE ALARM ......FIRE ALARM CONTROL PANEL MTG NC ......MOUNT ......MOUNTING V VA VOLTS ......VOLT-AMPERE FOR FEEDER NEC ......NORMALLY CLOSED W ......WATTS FL Ell FIRE ALARM HORN/SPEAKER (NOTE L-3) ......NATIONAL ELECTRICAL CODE WP ......WEATHERPROOF F FVNR ......FLOOR ......FUSE OR FUSED VOLTAGE NON NF NFPA ......NON FUSED ......NATIONAL FIRE PROTECTION ASSOCIATION XFMR XP .......TRANSFORMER ......EXPLOSION PROOF ......FULL REVERSING NIC ......NOT IN CONTRACT Y ......WYE DUCT MOUNTED SMOKE DETECTOR Z ......IMPEDANCE ELECTRICAL GENERAL NOTES G1 ALL CIRCUITS SERVING NIGHT/EMERGENCY LIGHTING SHALL CONTAIN AN ADDITIONAL, UNSWITCHED 'HOT' CONDUCTOR TO ENSURE EXIT AND EMERGENCY LIGHTING FIXTURES REMAIN ON/ACTIVE AT ALL TIMES. G2 WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT. 03 REFER TO THE APPROPRIATE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF THE DOCUMENTS WHICH REQUIRE ELECTRICAL SERVICE. 04 CAPITAL LETTER BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE SELECTION. G5 EQUIPMENT GROUNDING CONDUCTORS ARE TO BE INCLUDED IN ALL RACEWAYS, G6 ELECTRICAL CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH MECHANICAL, PLUMBING, ARCHITECTURAL, ETC..SYSTEMS BEING REMOVED. REMOVE ALL CONDUIT, WIRING, HARDWARE, DISCONNECTS, ETC. COMPLETELY BACK TO SOURCE. (NEAREST ACTIVE J --BOX TO REMAIN OR BRANCH CIRCUIT PANEL). G7 PROVIDE PLENUM -RATED WIRING MATERIALS AND METHODS AS REQUIRED PER ALL APPLICABLE CODES AND STANDARDS FOR ALL SPACES UTILIZED AS RETURN AIR PLENUM. Florida Department of Business & Professional (Regulation License Number 47111 a Expires 28 February 2009 O ■1 Jordan & Skala Engineers, Inc. LjProject Number 4 0860363 112.31 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 171 PHONE (281)617-3200 FAX (281)617-3207 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. 0 N 71 Revisions No. Date Description A0"f,22.2008 LL COMMENT5 Q0q.02.0& GITY GOMMENT5 THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECT: Interior Tenant Improvements for: Mattress Firm Seminole Town Center WP Ball & Town Center Blvd. Sanford, Florida 32771 THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBTIED. COPYRIGHT 2008 LARRY L. CHRISTIAN, A.I.A. ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION $ SINGLE POLE SINGLE THROW TOGGLE SWITCH (NOTE L-1) HE E HEIGHT 4 $3/$4 THREE-WAY TOGGLE SWITCH/FOUR-WAY TOGGLE SWITCH (NOTE L-1) 48,t M MOTOR RATED SWITCH DIMMER SWITCH (NOTE L-1) 48" [)) 3 THREE-WAY DIMMER SWITCH (NOTE L-1) 48" / DUPLEX / QUAD RECEPTACLE OUTLET (NOTE L-1) 18" Pq1 ("WP "=WEATHERPROOF, "GFI"=GROUND FAULT INTERRUPTER) 7F /TAG G.F.C.I. DUPLEX RECEPTACLE OUTLET WALL/ABOVE COUNTER MOUNTED (NOTE L-1) 18"/43" ISOLATED GROUND DUPLEX RECEPTACLE OUTLET 18" SPECIAL PURPOSE RECEPTACLE OUTLET, NEMA CONFIGURATION TO MATCH PLUG. (NOTE L-1) 18" m 1� SPLIT WIRED DUPLEX RECEPTACLE. ONE RECEPTACLE SHALL BE SWITCHED AS SHOWN ON PLANS (NOTE L-1) 18" n DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED/FLOOR MOUNTED JUNCTION BOX, CEILING/WALL/FLOOR MOUNTED 5 ARROWHEAD INDICATES HOMERUN. X-1,3,5 ADJACENT TO HOMERUN ARROWHEADS INDICATES HOMERUN TO PANEL X CIRCUIT NUMBERS 1,3, AND 5. RACEWAY/CABLE CONCEkED IN WALL AND/OR ABOVE CEILING FO -100 C�1 FLUORESCENT LIGHTING FIXTURE, 2X4, 1X4, 2X2 0 [�] FLUORESCENT LIGHTING FIXTURE, 2X4, 1X4, 2X2 - PROVIDING EMERGENCY ILLUMINATION O / Q LIGHTING FIXTURE - OVERHEAD/WALL MOUNTED 0 / EMERGENCY LIGHTING FIXTURE - OVERHEAD/WALL MOUNTED FLUORESCENT STRIP' FIXTURE - OVERHEAD/WALLMOUNTED f®f/� EXIT SIGN, CEILING/WALL, MOUNTED. PROVIDE ARROWS AS INDICATED ON DRAWINGS NNe EMERGENCY LIGHTING FIXTURE PANELBOARD - WALL MOUNTED (RECESSED) PANELBOARD - WALL MOUNTED (SURFACE) Q` MOTOR Lj60/3/3R NONFUSIBLE DISCONNECT SWITCH, RATING/POLES/NEMA ENCLOSURE 'I 60/3/3R/40 FUSIBLE DISCONNECT SWITCH, RATING/POLES/NEMA ENCLOSURE/FUSE RATING POWER METER AND SOCKET [_E1 FIRE ALARM MANUAL STATION 48" X110 FIRE ALARM HORN/SPEAKER WITH VISUAL DEVICE (NOTE L-3), NUMERAL INDICATES CANDELA RATING Ell FIRE ALARM HORN/SPEAKER (NOTE L-3) ©t10 FIRE ALARM VISUAL DEVICE (NOTE L-3), NUMERAL INDICATES CANDELA RATING Q/QI SMOKE DETECTOR (CEILING/WALL MOUNTED 4" MIN. AND 12." MAX. FROM CEILING) O THERMAL DETECTOR, CEILING MOUNTED OO CONNECTION TO FIRE PROTECTION SYSTEM FLOW SWITCH O CONNECTION TO FIRE PROTECTION SYSTEM TAMPER SWITCH DUCT MOUNTED SMOKE DETECTOR FR-SlREMOTE STATION FOR DUCT MOUNTED SMOKE DETECTOR U-0/_U22F FIRE ALARM CONTROL PANEL, SURFACE/RECESSED Lia I" FIRE ALARM ANNUNCIATOR PANEL, RECESSED TELEPHONE OUTLET, WALL MOUNTED/ABOVE COUNTER (NOTES L-1, L-2)/FLOOR MOUNTED COMBINATION TELEPHONE/DATA OUTLET, WALL MOUNTED/ABOVE COUNTER (NOTE L-1, L-2)/FLOOR A18"/43'?V/VVF- 0/$/ a DATA OUTLET, WALL MOUNTED/ABOVE COUNTER (NOTE L-1, L-2)/FLOOR MOUNTED 18"/43" TELEVISION OUTLET WALL MOUNTED (NOTE L-1)/CEILING MOUNTED/FLOOR MOUNTED 180 LEGEND NOTES L-1 MOUNTING HEIGHTS NOTED ARE TO THE CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE, L-2 STUB 3/4" CONDUIT 6" ABOVE ACCESSIBLE CEILING AND TERMINATE WITH NYLON GROMMET. L-3 FIRE ALARM VISUAL DEVICES SHALL BE WALL -MOUNTED 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER, AUDIBLE ONLY DEVICES SHALL BE WALL -MOUNTED AT NOT LESS THAN 90" AFF AND NOT LESS THAN 6" BELOW CEILING. ELECTRICAL GENERAL NOTES G1 ALL CIRCUITS SERVING NIGHT/EMERGENCY LIGHTING SHALL CONTAIN AN ADDITIONAL, UNSWITCHED 'HOT' CONDUCTOR TO ENSURE EXIT AND EMERGENCY LIGHTING FIXTURES REMAIN ON/ACTIVE AT ALL TIMES. G2 WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT. 03 REFER TO THE APPROPRIATE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF THE DOCUMENTS WHICH REQUIRE ELECTRICAL SERVICE. 04 CAPITAL LETTER BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE SELECTION. G5 EQUIPMENT GROUNDING CONDUCTORS ARE TO BE INCLUDED IN ALL RACEWAYS, G6 ELECTRICAL CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH MECHANICAL, PLUMBING, ARCHITECTURAL, ETC..SYSTEMS BEING REMOVED. REMOVE ALL CONDUIT, WIRING, HARDWARE, DISCONNECTS, ETC. COMPLETELY BACK TO SOURCE. (NEAREST ACTIVE J --BOX TO REMAIN OR BRANCH CIRCUIT PANEL). G7 PROVIDE PLENUM -RATED WIRING MATERIALS AND METHODS AS REQUIRED PER ALL APPLICABLE CODES AND STANDARDS FOR ALL SPACES UTILIZED AS RETURN AIR PLENUM. Florida Department of Business & Professional (Regulation License Number 47111 a Expires 28 February 2009 O ■1 Jordan & Skala Engineers, Inc. LjProject Number 4 0860363 112.31 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 171 PHONE (281)617-3200 FAX (281)617-3207 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. 0 N 71 Revisions No. Date Description A0"f,22.2008 LL COMMENT5 Q0q.02.0& GITY GOMMENT5 THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECT: Interior Tenant Improvements for: Mattress Firm Seminole Town Center WP Ball & Town Center Blvd. Sanford, Florida 32771 THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBTIED. COPYRIGHT 2008 LARRY L. CHRISTIAN, A.I.A. Lary L. C�jvistian A.I.A. 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 LEGEND 4 1�)ETAILS SHEET ELEOTRIGAL Date: 06-19-2008 Project No. 0805.776 Cl n Y con Pq1 H� CD lzt Lary L. C�jvistian A.I.A. 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 LEGEND 4 1�)ETAILS SHEET ELEOTRIGAL Date: 06-19-2008 Project No. 0805.776 Cl n Y USE EXISTING PHOTOCELL FOR TENANT EXTERIOR--- LIGHTING/SIGNAGE REQUIREMENTS TO EXTERIOR SIGNAGE LC -C2 ROOF MULTI—POLE MECHANICALLY HELD CONTACTOR (POLES AS REQUIRED) (TYPICAL OF 2) TENANT PANELTIMECLOCK. SEE A LC -C 1 SPECIFICATIONS 1 (TYPICAL OF 2) TO INTERIOR LIGHTS MANUAL OVER—RIDE TOGGLE SWITCH FIGHTING CONTACTOR SCHEDULE CONT. DESCRIPTION LOAD CONTACTOR CIRCUIT CONTROL CIRCUIT VOLT AMPS POLE CIRCUITS VOLT CKT. NO. # I SERVED LC—C1 INTERIOR LIGHTING 120 20 6 A-3,5,7,9 120 A-21 KELVIN TEMP: 3500 ARCHITECT. REPRODUCTION IS PROHIBITED. ON — 7:00 AM AE 2'x4', 3—LAMP RECESSED ACRYLIC LENS TROFFER, GENERAL GRADE, GE LIGHTING NAED: 25612 FURNISHED BY (1) MULTI—VOLT ELECTRONIC BALLAST, GRID TYPE. COOPER: F32T8/SPX35/ECO OFF — 12:00 AM (MIDNIGHT) 20R8-332A—UNV—EB8I—EM—U; MVOLT 1/3 GEB101S; WITH INITIAL LUMENS: 2950 CRI: 85 BY G.C. LC—C2 EXTERIOR SIGNAGE 120 20 6 A-13,15,17,19 120 A-21 B ON 5:00 PM GE LIGHTING NAED: 25612 FURNISHED BY OFF — 9:00 AM F32T8/SPX35/ECO TENANT, INSTALLED INSIDE CUSTOMER NOTES INITIAL LUMENS: 2950 CRI: 85 BY G.C. SERVICE VALANCE EXISTING LIGHTING CONTROL SHALL REMAIN AS CONNECTED. KELVIN TEMP: 3500 LIGHTING CONTROL DETAIL & SCHEDULE N.T.5. u TYPE DESCRIPTION LAMPS NOTES LEGEND A 2'x4', 3—LAMP RECESSED ACRYLIC LENS TROFFER, GENERAL GRADE, GE LIGHTING NAED: 25612 FURNISHED BY Mattress Firm (1) MULTI—VOLT ELECTRONIC BALLAST, GRID TYPE. COOPER: F32T8/SPX35/ECO TENANT, INSTALLED Sanford, Florida 32771 2GR8-332A—UNV—EB8I—EM—U; MVOLT 1/3 GEB1OlS; INITIAL LUMENS: 2950 CRI: 85 BY G.C. PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE KELVIN TEMP: 3500 ARCHITECT. REPRODUCTION IS PROHIBITED. AE 2'x4', 3—LAMP RECESSED ACRYLIC LENS TROFFER, GENERAL GRADE, GE LIGHTING NAED: 25612 FURNISHED BY (1) MULTI—VOLT ELECTRONIC BALLAST, GRID TYPE. COOPER: F32T8/SPX35/ECO TENANT, INSTALLED 20R8-332A—UNV—EB8I—EM—U; MVOLT 1/3 GEB101S; WITH INITIAL LUMENS: 2950 CRI: 85 BY G.C. EMERGENCY BATTERY PACK KELVIN TEMP: 3500 B 8' 4—LAMP GENERAL PURPOSE CHANNEL SLIMLINE STRIP FIXTURE, GE LIGHTING NAED: 25612 FURNISHED BY F.S. BALLAST; LITHONIA: TC -232 MULTI—VOLT G.E.B. F32T8/SPX35/ECO TENANT, INSTALLED INSIDE CUSTOMER INITIAL LUMENS: 2950 CRI: 85 BY G.C. SERVICE VALANCE KELVIN TEMP: 3500 D 4' 2—LAMP GENERAL PURPOSE CHANNEL SLIMLINE STRIP FIXTURE, GE LIGHTING NAED: 25612 FURNISHED BY VALUE CENTER E.S. BALLAST; LITHONIA: C 2 32 MULTI—VOLT G.E.B. F32T8/SPX35/ECO TENANT, INSTALLED INITIAL LUMENS: 2950 CRI: 85 BY G.C. ENTER F 6 VOLT TWIN—HEAD BATTERY LIGHT, SURFACE MOUNTED. INCLUDED FURNISHED BY LITHONIA: ELM2-120V TENANT, INSTALLED BY G.C. GNHEC XHAU FAN, EL —A110; CFM, GRA RE: HED G.C. DOWNDRAFT DAMPER, WALL SWITCH, & DISCONNECT X L.E.D. EXIT SIGN WITH POLYCARBONATE HOUSING, RED L.E.D. FURNISHED BY LETTERS, BATTERY BACK—UP, LITHONIA: LQM S W 3 R OWNER 120/277 EL N NOTES G.C. RESPONSIBLE FOR PROVIDING LIGHTING VENDOR COUNTS BY TYPE REQUIRED TO PERFORM ALL WORK ACCORDING TO PLANS LIGHTING VENDOR: AMERICAN LIGHT, 5091 STEADMONT, HOUSTON, TEXAS 77040 CONTACTS: ALLYN BOSTICK, MIKE FONT, STEVE BROWN PHONE: 800-880-1407 FAX: 713-462-6282 LIGHTING FIXTURE SCHEDULE N.T.5. A-17,1 oD- LIGHTING PLAN -ELECTRICAL I/E)II= 11-011 KEY NOTES: O1 ROUTE SHOWROOM & CLEARANCE AREA LIGHTING CIRCUITS THROUGH TIMECLOCK/CONTACTOR TO COMPLY WITH STATE ENERGY CODE. EXIT AND EGRESS/EMERGENCY LIGHTING SHALL BE CONNECTED UNSWITCHED. PROVIDE ACCORDINGLY. PROVIDE MANUAL OVERRIDE SWITCH FOR SHOWROOM & CLEARANCE AREA LIGHTING.. O MANUAL OVER—RIDE SWITCH FOR LIGHTING CONTROL. PROVIDE IDENTIFICATION LABEL ON SWITCH, O OCCUPANCY SENSOR NOTE FOR FILES/RECORDS ROOM LIGHTING. LEVITON #ODS15—ID. �4 J—BOX TO POWER BUILDING SIGNAGE. GENERAL NOTES: G-1 EXHAUST FANS SHALL BE CONNECTED TO LIGHTING CIRCUIT AND SWITCHED WITH LIGHTS. 0-2 ALL EXIT AND EMERGENCY EGRESS FIXTURES SHALL BE CONNECTED UNSWITCHED UNLESS NOTED OTHERWISE. El Revisions No. Date Description ZL01.22.2008 11 COMMENTS QI 041.02.08 OITY OOMMEW5 ILESI SOROS 105 MEN 103 -TALL 102 v�IOM�N 104 Florida Department of Business & Professional Regulation License Number 4711 - Expires 28 February 2009 NORTH Jordan & Skala Engineers, Inc. Project number o 086-0363 11231 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 171 PHONE (281)617-3200 FAX (281)617-3207 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. ® N L 0 El 0 F Lary L. C Yistian A.I.A. f-1 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 LICHTINC PLAN ELEGTRIGAL I� Date: 06-19-2008 - --- Project No. 0805'-776 m 0 THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECT: 'AL.UE Interior Tenant Improvements for: ENTER Mattress Firm Serninole Town Center 106 WP Ball & Town Center Blvd. Sanford, Florida 32771 'WROOM THEY ARE NOT SUITABLE FOR USE ON OTHER 101 PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBITED. COPYRIGHT 2008 LARRY L. CHRISTIAN, A.I.A. ILESI SOROS 105 MEN 103 -TALL 102 v�IOM�N 104 Florida Department of Business & Professional Regulation License Number 4711 - Expires 28 February 2009 NORTH Jordan & Skala Engineers, Inc. Project number o 086-0363 11231 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 171 PHONE (281)617-3200 FAX (281)617-3207 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. ® N L 0 El 0 F Lary L. C Yistian A.I.A. f-1 3801 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 LICHTINC PLAN ELEGTRIGAL I� Date: 06-19-2008 - --- Project No. 0805'-776 m 0 LIGHTING 12.90 KVA X 100 % = 12.9 KVA PANELBOARD SCHEDULE -'A' KVA IST 10.00 KVA X 100 % = 6.4 KVA REMAIN 0.00 KVA X 50 % = 0.0 KVA MAIN: MLO 400 VOLTAGE: 208/120 PHASE: 3 1 WIRE: 4 MOUNTING: SURFACE 65 AIC: 22K NOTES: CKT TRIP # POLE DESCRIPTION LOAD (KVA) PHASE LTG REG LOAD (KVA) MTR AIC7 HTG KIT MISC DESCRIPTION TRIP CKT POLE # LTG REC MTR7 A/C HTG KIT MISC A B C 1 20/1 1 LIGHTS -EMERGENCY 1.2 1.2 1.2 1.2 1.2 0.7 1.2 1.2 1.2 1.2 0.4 0.4 0.4 _ 1 Q6 _ 0.4 0.6 0.2 1.1 1.1 0.2 1.1 0.4 0.4 0.2 0.9 0.4 0.4 0.4 0.4 0.4 0.4 1.5 9.0 9.0 9.0 9.0 9.0 9.0 0.6 0.6 TELEPHONE BOARD EWH-1 EWC RECP-TOILET RECP-HALL RECP-CUSTOMER COUNT RECP-SHOW ROOM RECP-SHOW ROOM RECP-SHOW WINDOW RECP-SHOW ROOM RECP-SHOW ROOM RECP-ROOF TOP RTU -1 -_- =__ RTU -2 -__ -__ RECP-SHOW ROOM RECP-FILES/RECORDS SPACE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 80/3 __= _-= 80/3 __= __- 20/1 20/1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 3 1 20/1 LIGHTS -SHOW ROOM 5 1 20/1 LIGHTS -SHOW ROOM 7 1 20/1 LIGHTS -SHOW ROOM 9 1 20/1 LIGHTS -SHOW ROOM 11 1 20/1 LIGHTS-FILES/RECORD 13 20/1 1 LIGHTS -BUILDING SIGNAGE 15 20/1 LIGHTS -BUILDING SIGNAGE 17 20/1 LIGHTS -BUILDING SIGNAGE 19 20/1 LIGHTS -BUILDING SIGNAGE 21 20/1 LIGHTING CONTROL 23 20/1 RECP-SHOW WINDOW 25 20/1 RECP-SHOW WINDOW 27 20/1 RECP-SHOW WINDOW 29 SPACE 31 SPACE _ 33 SPACE T 35 SPACE 37 SPACE 39 ISPACE 41 SPACE LIGHTING (KVA): 12.9 12.7 0.0 0.0 1 0.0 1 0.0 0.0 0.6 0.2 6.4 1 1 .0 55.5 1 .0 1 1.2 CONNECTED LOAD (KVA): 79.1 RECEPTACLES (KVA): 6.4 DEMAND LOAD (KVA): 79.1 MOTORS (KVA): 2.5 PHASE A 27 228.5 _ A/C (KVA): 0.0 PHASE B 28 232.7 CONNECTED LOAD (AMPS): 219.4 HEATING (KVA): 55.5 PHASE C 24 197.7 DEMAND LOAD (AMPS): 219.4 KITCHEN (KVA): 0.0 KVA AMPS MISCELLANEOUS (KVA): 1.8 AMPACITY REQUIRED: 228.4 NOTES: LIGHTING 12.90 KVA X 100 % = 12.9 KVA RECEPTACLE TOTAL 6.40 KVA IST 10.00 KVA X 100 % = 6.4 KVA REMAIN 0.00 KVA X 50 % = 0.0 KVA MOTORS 2.46 KVA X 100 % = 2.5 KVA A/C 0.00 KVA X 100 % = 0.0 KVA HEATING 55.50 KVA X 100 % = 55.5 KVA LOCKED -OUT LOAD KVA X 100 % = 0.0 KVA KITCHEN 0.00 KVA X 65 % = 0.0 KVA MISCELLANEOUS 1.80 KVA X 100 % = 1.8 KVA TOTAL = 19.1 KVA TO EXISTING PAD MOUNTED UTILITY S--------' -------- CO. XFMR 208/120 V, 30 EXISTING SERVICE FEEDER �.-�.._...---------_....-..._.._._-. --------...�.-J EXISTING UNDERGROUND RISER NOTES: CONDUIT.(NOTE 3) 1. ALL EXISTING ELECTRICAL SHALL BE REUSED UNLESS NOTED OTHERWISE, 2. ALL FEEDER CONDUCTOR SHALL BE COPPER UNLESS OTHERWISE NOTED, 3. CONNECT NEW CONDUIT TO EXISTING AND PROVIDE NEW CONDUCTOR AS INDICATED. EXISTING / NEW ELECTRICAL RISER N.T.S. 1021 A, 5 POWER PLAN - ELECTRICAL I/all = I1 GENERAL NOTES: G-1 ELECTRICAL CONTRACTOR SHALL VERIFY HEIGHT ELEVATIONS & EXACT LOCATION OF ALL DEVICES WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION. KEY NOTES: O RECEPTACLE MOUNTED BELOW CEILING. FOR SHOW WINDOW LIGTHING. O FLUSH -IN -FLOOR POWER AND DATA OUTLETS AND/OR CONDUIT STUB -UPS INTO SALES DESK. VERIFY REQUIREMENTS WITH ARCHITECT AND OWNER, O3 PROVIDE 2" CONDUIT FOR TELEPHONE SERVICE FROM BUILDING'S MAIN TELEPHONE SERVICE PANEL, RECEPTACLE SHALL BE INSTALLED ADJACENT TO TELEPHONE BACKBOARD AT 42" AFF. ® PROVIDE NEW ROOF MOUNTED 20A, WEATHERPROOF/GFI, DUPLEX RECEPTACLE, O5 CEILING MOUNTED RECEPTACLE FOR CUSTOMER COUNTING DEVICE. zi 6 ROUTE CIRCUIT UNDER GRADE AND UP COLUMN TO CEILING SPACE AND TERMINATED AT PANEL 'A' IN RECORDS ROOM. L /ALUE ENTER os )WROOM 1o1 :I L ES/ GORL:)10 9 MIEN 103 1 U'L rvOM�N 104 #6 AWG COPPER GROUNDING CONDUCTOR CONNECTED TO MAIN ELECTRICAL GROUND, TELEPHONE BOARD GROUNDING N.T.S. Revisions No. Date Description ® �I AA D-1.22.20oa LL GOMMENT5 Q0q.02.08 GITY COMMENTS THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECF. Interior Tenant ImprovernentS for: Mattress Firm Seminole Town Center WP Ball & Town Center Blvd. Sanford, Florida 32771 THEY ARE NOT SUITABLE FOR USE ON 0T1IER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT, REPRODUCTION IS PROHIBITED. COPYRIGHT 2008 LARRY L. CHRISTIAN, A.I.A. ® ®I E Florida Department of Business & Professional (Regulation License Number 47111 Expires 28 February 2009 NORTH Lary Lo C ristian A.I.A. 71 3801 Kirby Dr., Suite 600 IIoustou, Texas 77098 tel: 713 664 7974 :fax: 713 664 9756 d POWER PLAN ELFGTRIGAL Jordan & Skala Engineers, Inc. E- 73 Project Number - 086.0363 31 11231 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 171 PHONE (281)617-3200 FAX (281)617-3207 ® � Date: 06-19-2008 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. Project No. 0805-776 FIXTURE SPECIFICATIONS PLUMBING FIXTURES SHALL BE AS SPECIFIED BELOW P1 H WATER CLOSET - HANDICAPPED: AMERICAN STANDARD: 2998.012 FLOOR MOUNTED, TANK TYPE COMBINATION DESCRIPTION FIXTURE, 1.6 GPF, VITREOUS CHINA, A/C ELONGATED BOWL, BOLT CAPS, WATER CLOSET -TANK WHITE FINISH, ABOVE FLOOR SEAT: BENEKE: 523 -SS COMMERCIAL GRADE, SOLID PLASTIC, 3" ELONGATED, OPEN FRONT LESS COVER, BELOW COUNTER STAINLESS STEEL CHECK HINGE, B/F WHITE FINISH. MCGUIRE: H2165 SUPPLY: MCGUIRE: H2169 1/2"IPS x 1/2"OD ANGLE STOP, WHEEL CO HANDLE, WALL FLANGE, CHROME 1/2" PLATED. COLD WATER PIPING P2H LAVATORY - HANDICAPPED: AMERICAN STANDARD: 0356.028 21" x 18" WALL HUNG, VITREOUS CHINA, #E -77 -AA VINYL BUMPERGUARD, 4"CENTERS, BACKSPLASH & FRONT P5H LAVATORY - HANDICAPPED: OVERFLOW, CONCEALED ARM SUPPORT, VITREOUS CHINA, COUNTER TOP MOUNT, WHITE FINISH. FRONT OVERFLOW, WHITE. FAUCET: AMERICAN STANDARD: 2385.006 SINGLE LEVER HANDLE, TWO HANDLE 4"CENTERS, POLISHED CHROME. LEVER HANDLES. .5 GPM AERATOR SUPPLIES, DRAIN, TRAP AND INSULATION KIT SIMILAR SUPPLIES: MCGUIRE: H2165 1/2"IPS x 3/8"OD ANGLE STOP, WHEEL P=TRAP HANDLE, WALL FLANGE, CHROME S,W PLATED. -- _S__ DRAIN: MCGUIRE: 155WO 1-1/4", 17 Ga., OFFSET DRAIN WITH TP OPEN GRID STRAINER, 1-1/4" TAILPIECE, _HIS_ CHROME FINISH. UNION TRAP: MCGUIRE: 8902 1-1/4" x 1-1/2", 17 Go., ADJUSTABLE -- — — — TRAP WITH CLEANOUT PLUG AND WALL VENT PIPING FLANGE, CHROME FINISH. WCO INSULATION KIT: HANDI-LAV: 102 & 105 SELF -FASTENING, VINYL INSULATION COVERS CONNECT NEW TO EXISTING PIPING FOR DRAIN, TRAPS AND SUPPLY PIPING WITH ACCESSIBLE ANGLE VALVE INSULATION COVER, WHITE. CARRIER: JR SMITH: 700 SERIES ADJUSTABLE FLOOR SUPPORT WITH CONCEALED ARMS. P3H WATER COOLER - HANDICAPPED: OASIS: P8AMSL BI -LEVEL ELECTRIC WATER COOLER, DESCRIPTION STAINLESS STEEL BOWLS, HAND A/C OPERATED CONTROLS, ONE UNIT WATER CLOSET -TANK WITH REFRIGERATION SYSTEM ABOVE FLOOR TRAP: MCGUIRE: 8902 1-1/4" x 1-1/2", 17 Ga., ADJUSTABLE 3" TRAP WITH CLEANOUT PLUG AND WALL BELOW COUNTER FLANGE, CHROME FINISH. B/F SUPPLY: MCGUIRE: H2165 1/2"IPS x 3/8 -OD ANGLE STOP, WHEEL VENT TROUGH ROOF HANDLE, WALL FLANGE, CHROME CO PLATED, 1/2" P4 MOP SINK - FLOOR MOUNTED: COLD WATER PIPING FIAT #MSB -2424, 24" SQUARE x 10" HIGH, WITH #830 -AA FAUCET, #832 -AA -30 HOSE AND BRACKET, #889 -CC -24" MOP HANGER, #E -77 -AA VINYL BUMPERGUARD, #833 -AA SILICONE SEALANT. EQUAL BY STERN-WILLIAMS. P5H LAVATORY - HANDICAPPED: AMERICAN STANDARD VITREOUS CHINA, COUNTER TOP MOUNT, AQUALYN #0475.020 FRONT OVERFLOW, WHITE. --�- - FAUCET: KOHLER 'TRITON': #K -7443-K TWO HANDLE WITH #K-16012-4 HANDLES LEVER HANDLES. — -- — SUPPLIES, DRAIN, TRAP AND INSULATION KIT SIMILAR 'TO P2H. PLUMBING NOTES 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ALL PLUMBING FIXTURES. 2, ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE FLORIDA PLUMBING CODE 2004 AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 3. ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED FROM 'THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR BE SUPPORTED FROM CEILING -TILES. 4. SANITARY AND DRAINAGE PIPING SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM. 5. LOCATE ALL SECTIONAL OR MAIN CONTROL VALVES WITHIN 1'-0" FROM ACCESS PANELS, CEILING TILES, OR OTHER POINT OF ACCESS, 6. ALL COLD WATER, HOT WATER AND DRAIN PIPING AT HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI-LAV GUARD MODELS 102 AND 105 INSULATION KITS. 7. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND -THE ELECTRICAL CONTRACTOR, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. 8. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC. INSTALLED IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 9. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE, 10. ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE RATED ASSEMBLIES SHALL BE FIRE STOPPED AS REQUIRED TO RESTORE ASSEMBLY TO ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY 3M COMPANY, CP25 CAULK, CS195 COMPOSITE PANEL, FS195 WRAP/SRINK, OR PSS 7900 SERIES SYSTEMS AS RECOMMENDED BY MANUFACTURER FOR PARTICULAR APPLICATIONS, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS. 11. WATER CLOSET FLUSH LEVERS SHALL BE LOCATED ON THE APPROACH SIDE OF THE TANK. 3/4"HW TO PUBLIC LAVATORIES I WITH HEAT TRAP 1� NOTE: FIRST EIGHT FT. OF COLD &. HOT WATER SHALL BE INSULATED WITH 1 MIN. 1/2" INSULATION. I I GATE/BALL VALVE (TYP)—\ 3/4"CW SUPPLY \I WITH HEAT TRAP-\ i 1/2"CW W/GV TO AUTOMATIC TRAP PRIMER WITH DISTRIBUTION BOX 1/2"TYPE K COPPER TUBING TP SUPPLY TO EACH FLOOR DRAIN 2" x 2" x 1/4" GALVANIZED ANGLE IRON FRAME u ASME T & P RELIEF VALVE - PIPE FULL SIZE TO MOP SINK 1-1/2" MIN. HIGH SAFETY PAN SOLDER SEAMS WATER -TIGHT WATER HEATER DRAIN PAN. PIPE FULL SIZE TO MOP SINK DIELECTRIC UNION (TYP FOR 2) DETAIL: @ WATER HEATER 3/4" 0 CADMIUM -PLATED ALL THREAD ROD WITH LOCK WASHERS AND DOUBLE NUTS (TYP. 4) —THERMAL EXPANSION TANK, 2 GALLON, AMTROL OR EQUAL. /---VACUUM RELIEF VALVE WALL ----�I NO SGALE 02 DRAINAGE PRODUCTS/SPECIALTIES UNLESS OTHERWISE INDICATED NUMBERS ARE JAY R. SMITH, EQUAL PRODUCTS: ZURN, JOSAM, WADE AND WATTS. FD "F" - FLOOR DRAINS-MECH./FUNNEL JAY R. SMITH FIG. 2005/2010-136-1`12-B SERIES C.I. FLOOR DRAIN WITH 6" SQUARE NICKEL BRONZE STRAINER WITH 4" DIAMETER SECURED FUNNEL, SPEEDI-SET OUTLET CONNECTION AND TRAP PRIMER CONNECTION. FD "G" - FLOOR DRAINS-GENERAL/RESTROOMS JAY R. SMITH FIG. 2005-B6 SERIES C.I. FLOOR DRAIN WITH 6" DIAMETER SQUARE NICKEL BRONZE STRAINER, SPEEDI-SET OUTLET CONNECTION AND TRAP PRIMER CONNECTION, TP -"A" -AUTOMATIC TRAP PRIMER PPP PRIME -RITE SERIES AUTOMATIC TRAP PRIMER WITH MULTIPLE OUTLET DISTRIBUTION UNITS AS REQUIRED. WOO -WALL CLEANOUT - FINISHED AREAS JAY R. SMITH FIG. 4436 C.I. FERRULE FOR NO HUB OR SERVICE WEIGHT PIPE, NICKEL BRONZE ROUND FRAME AND COVER WITH SECURING SCREWS. FCO CLEAN-OUT TO BE BRASS PLUG AND COVER, SET FLUSH WITH FLOOR SURFACE. PLUMBING MATERIALS 1. COLD AND HOT WATER PIPING ABOVE GRADE SHALL BE TYPE L HARD DRAWN COPPER TUBING CONFORMING TO ASTM B-88 WITH SWEAT JOINTS AND CAST OR WROUGHT FITTINGS. ALL JOINTS SHALL BE MADE WITH LEAD FREE SOLDER. 2. SANITARY WASTE & VENT PIPING ABOVE GROUND SHALL BE NO -HUB CAST-IRON WITH STAINLESS STEEL COUPLINGS. 3. SANITARY WASTE PIPING BELOW GROUND SHALL BE SCHEDULE 40 DWV PVC. 4. ALL ABOVE GRADE HOT AND COLD DOMESTIC WATER PIPING SHALL BE INSULATED EXCEPT AT HORIZONTAL CHASE BRANCH PIPING TO INDIVIDUAL PLUMBING FIXTURES. ALL HOT WATER PIPING SHALL BE INSULATED WITH 1" NOMINAL THICKNESS PIPE INSULATION WITH VAPOR BARRIER JACKET, ALL COLD WATER PIPING ABOVE GRADE SHALL BE INSULATED WITH 1/2 INCH THICKNESS INSULATION. OWENS-CORNING ASJ/SSLII, OR EQUAL. PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION FIXTURE # FIXTURE TYPE WASTE HOT WATER COLD WATER A/C ABOVE CEILING WATER CLOSET -TANK A/F ABOVE FLOOR 1/2" AP ACCESS PANEL 3" B/C BELOW COUNTER P2H B/F BELOW FLOOR 1/2" VTR VENT TROUGH ROOF IF— CO CLEANOUT 1/2" CW COLD WATER PIPING 3" 1/2" DN PIPING TURNING DOWN G G GAS PIPE (LOW PRESSURE 7" W.C.) --- GC GAS COCK --�- - GV GATE/BALL VALVE HC HANDICAPPED — -- — HW HOT WAFER PIPING --- P=TRAP S S,W SOIL, WASTE PIPING (ABOVE GROUND) -- _S__ S,W SOIL, WASTE PIPING (BELOW GROUND) TP TRAP PRIMER _HIS_ --- UNION �-- UP PIPING TURNING UP -- — — — V VENT PIPING WCO WALL CLEANOUT --- CONNECT NEW TO EXISTING PIPING NOTES BY SYMBOL: �1 3"S DN, 2"V UP W/WCO O 2"S DN, 2"V UP W/WCO Q3 3/4"CW DN TO WATER HEATER (EWH-1), 3/4" HW TO FIXTURES. ®1 /2"CW & HW DN TO MOP SINK 01 /2"CW DN TO WATER CLOSET.. ©3/4"CW & 1/2"HW, DN TO FIXTURES. EXTEND 1/2"CW & HW TO LAVATORY. EXTEND 1/2"CW TO EACH WATER COOLER. O7 1 /2"CW & 1 /2"HW, DN TO LAVATORY. ® EXTEND AND CONNECT AS REQUIRED THE NEW 1" CW LINE TO THE EXISTING 1-1 2"CW SERVICE AND MAKE FINAL CONNECTION. CONTRACTOR SHAL FIELD VERIFY EXACT LOCATION OF EXISTING CW SERVICE, IF EXISTING WATER SERVICE IS NOT PROVIDED WITH A BACKFLOW PREVENTER, PROVIDE BACKFLOW PREVENTER PER LOCAL AUTHORITIES HAVING JURISDICTION. PROVIDE ISOLATION VALVE AT NEW CONNECTION. 9O EXTEND AND CONNECT AS REQUIRED THE NEW SANITARY SEWER B/F TO EXISTING SANITARY SEWER MAIN, SEE PLANS FOR SIZES, OG— FIELD VERIFY DIRECTION OF SANITARY SEWER FLOW PRIOR TO INSTALLATION. PIPE CONNECTION TO EXISTING MAIN ACCORDINGLY. SAWCUT FLOOR AS REQUIRED TO MAKE CONNECTION TO EXISTING SANITARY SEWER. PATCH FLOOR TO MATCH FINISH SURFACE. 10 EXISTING TENANT SUB METER AND SHUT-OFF VALVE, 11 EXTEND AND CONNECT AS REQUIRED THE NEW VENT TO EXISTING 3" VTR. SEE PLANS FOR SIZES. FIELD VERIFY LOCATION PRIOR TO INSTALLATION AND CONNECTION. PATCH ROOF TO MATCH FINISH SURFACE. 3/4" 3/4 1/2', EWH-1 P2H P3H 1/2" 1 /2", [1/2" 3/4" ""1 /2„ L L P2H P1H P4 1/2 PIH WATER RISER DIAGRAM. NO 5_ -ALE i EXISTING 3"VTR J 11 2 EXISTING 4" SAN. � CAPPED. V� ice' i I 9 " WCO i � P2H 12"1 I's 2" r 2„� N. \„ P4 (2” WCO „1 H 2" �� P1 =F P3 WCO 4» 2' 3' 3"" P3H 2 — 2„i 4„ 2” 2" " 3 3» , � WCO 3» 3„ 2„ P2H " PIH WCO SANITARY RISER DIAGRAM. NO SCALE 03 Hoor P PLUMBING FIXTURE SCHEDULE MINIMUM SIZE UTILITY TO FIXTURE �"'�Tatw -u.S:T�� c?�"h ung >w'.4.. t.l ,4 kMr 'rt o �ul'y� ��raxrcn enm> ��q a�VV°�raP• FIXTURE # FIXTURE TYPE WASTE HOT WATER COLD WATER CONNECTION SUPPLY SUPPLY P1 WATER CLOSET -TANK 3" --- 1/2" PIH WATER CLOSET -TANK -HC 3" --- 1/2" P2H LAVATORY -WALL HUNG -HC 1-1/4" 1/2" 1/2" P3H ELEC . WATER COOLER -HC 1-1/4" --- 1/2" P4 MOP SINK -FLOOR MOUNTED 3" 1/2" 1/2" P5H COUNTERTOP LAVATORY 1 1/4" 1/2" 1/2" WATER HEATER SCHEDULE STORAGE GPH ELECTRICAL CRITERIA SYMBOL MANUFACTURER\ CAPACITY REC. @ 80'F OUTLET KW MODEL NO. GALLONS RISE TEMPERATURE INPUT NOTES EWH-1 A.O. SMITH NO. DEL -6 6 8 110'F 1.5 1 1-5 NOTES: 1. PROVIDE EXPANSION TANK SIZED PER WATER HEATER MANUFACTURER'S RECOMMENDATION 2. T&P RELIEF VALVE. 3. GATE/BALL VALVES WITH UNIONS AND DIELECTRIC FITTINGS ON WATER INLET AND OUTLET CONNECTIONS. 4, HEATER SHALL MEET 2003 INTERNATIONAL ENERGY CONSERVATION CODE REQUIREMENTS. 5. PROVIDE HEATER WIRED FOR VOLTAGE AND PHASE SHOWN ON ELECTRICAL PLANS. FIELD COORDINATE WITH ELECTRICAL CONTRACTOR 01 'AL_UE 'LATER 106 VROOM 101 J. TING FCO TYP. 10 1-1/2"CW IL -ES/ %ORrJS 105 MEN 103 BALL 102 ' SAN YNCVMtN 104 Florida (Department of Business & Professional Regulation License Number 4711 a Expires 28 February 2009 Jordan & Skala Engineers, Inc. Project (`lumber 4 086.0363 11231 RICHMOND AVE., SUITE 104 HOUSTON, TX 77082 NORTH Revisions No. Date Description A01=200& LL COMMENF5 I� 09.02.05 GIT'r COMMENTS M THESE DOCUMENTS HAVE BEEN PREPARED SPECIFICALLY FOR THE FOLLOWING PROJECT. Interior Tenant Improvements for: Mattress Firm Seminole Town Center WP Ball & Town Center Blvd. Sanford, Florida 32771 THEY ARE NOT SUITABLE FOR USE ON OTHER PROJECTS, OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF THE ARCHITECT. REPRODUCTION IS PROHIBITED. COPYRIGHT 2008 LARRY L. CHRISTIAN, A.I.A. E ■ C LaryN L. C ristian A.I.A. 380 Kirby Dr., Suite 600 Houston, Texas 77098 tel: 713 664 7974 fax: 713 664 9756 1-1 LEGEND, DETAILS, SCHEDULE, AND FLOOR PLAN - PLUMBING PHONE (281)617-3200 FAX (281)617-3207 Date: 06-19-2008 COPYRIGHT © 2008 JORDAN & SKALA ENGINEERS INC. Project No. 0805-776