HomeMy WebLinkAbout2111 WP Ball Blvd (fr alarm) + (a)Job Address: 2111 WP BALL BLVD.. Historic District: "Yes ❑ No 0 Parcel ID: 32-19-30-507-0000-0090 Residential ❑ Commercial FX Type of Work: New ❑ Addition ❑ Alteration 0 Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: ADD 1 STROBE IN NEW RESTROOM AT KOl NAIL SALON TO EXISTING POWER SUPPLY. Plan Review Contact Person: Steven Davis Title: Design Manager Phone: 407-227-0242 Fax: 407-328-3001 Email: sdavis@delta-fire.com Property Owner Information Name WRI SEMINOLE MARKETPLACE LLC Phone: Street: 1751 W P BALL 1771 & 1393 BLVD City, State Zip: SANFORD, FL 32771 Name Delta Fire Sprinklers, Inc. Street: 111 Tech Drive City, State Zip: Sanford, FL 32771 Resident of property? : PLACE OF BUSSINESS Contractor Information Phone: 407-328-3000 Fax: 407-328-3001 State License No.: EF20000767 Architect/Engineer Information Name: N/A Phone: Street: Fax: City, St, Zip: Bonding Company: N/A Address: E-mail: Mortgage Lender: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5' Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application �e,p,, D17TAII EXISTING CLEARANCE MIM j MIM FOR I WATEROF[TOW AND % WTh%RN UJ+R8RTION PI 5 £# I. 3 V��ej� I x'> ...,... ql $c�M1 It #' _.. ., ... ,. ilii 8## 33 ..�I.., ...3'73-1_1[__n+,,.✓i3 ,i J ai Q tgqiqq © 2 BG-12LX I FIRE LITE ADDRESSABLE MANUAL PULL STATION SCALE: 3/16 = T-0" MMF-100 FIRE LITE 80'-0" CQ 7 1 P2R SYSTEM SENSOR WALL MOUNTED HORN STROBE ® 4 SR SYSTEM SENSOR WALL MOUNTED STROBE � O I NEW � FIRE SPRINKLER VALVE TAMPER / FLOW SWITCH OFFICE R/R I _—__..__. _...... _.._._ .............. L ---� L .._�I O CCL I HIL .................... RoTic EXIST. OFFICE WAX ................ .............. R/R RM _._........ EX�S I G LL STq -'--_- '_�, _ ANDTHNORNUSTROBETI I A JIJ ••. N", „F SCALE: 3/16" =1'-0" ...._.... .. 47 K EOL II 10 J 8 7 FIRE LITE f CF5 4MEOW 2458 NAC 214AWG FPLR ssd , a ..... 6 5 4 3 2 1 18AWG FPLR INPUT CIRCUIT TO FACP 2 FIRE ALARM RISER DIAGRAM SCALE: NTS TO UNIT SANVORO r"a WAD AND THESE PI. S ARE . CONDITIONALOE PERMIT. AN ISSUES PERWT OROW DEEMED PERMIS WITH WORK AND CEOLAS AUTk(Xfq . TO VIOLATE, GAN tovisloa ASIDE- ANY OF THESE PF THE TEGHNIGAL CODES, ISSUANCE OF APCE7NMDIVSO` OO FIRE PREVENTI TIIL" 4-�EAFTE REQU RS CORRECTION '0 Qin OTHERVI CATIONS OF THE CQ 0 GENERAL NOTES: 1. ALL DETECTION, CONTROL AND NOTIFICATION COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70, (2011 EDITION), AND 72, (2010 EDITION). 2. ALL PULL STATIONS INSTALLED SHALL BE DUAL ACTION AND WEATHERPROOF. 3. PULL STATIONS (WHERE INSTALLED) SHALL BE MOUNTED SECURELY, WITH THE OPERABLE PART OF EACH DEVICE NOT LESS THAN 42" NOR MORE THAN 54" AFF, AS REQUIRED BY NFPA 72, 5.12.4. NORMAL MOUNTING HEIGHT IS 48" AFF. 4, WALL -MOUNTED AUDIO AND VISUAL DEVICES SHALL BE INSTALLED WITH THEIR BOTTOMS NOT LESS THAN 80" NOR MORE THAN 96" AFF, AS REQUIRED BY NFPA 72, 7.5.4. PER ADA, WALL MOUNTED AUDIO AND VISUAL DEVICES SHALL BE INSTALLED AT 80" AFF OR 6" BELOW THE FINISHED CEILING, WHICHEVER IS; LOWER. NORMAL MOUNTING HEIGHT IS 80" AFF. 5. POWER TO THE FIRE ALARM CONTROL PANEL SHALL BE ON A DEDICATED CIRCUIT WITH A LOCKING BREAKER, OR TO OTHER LOCAL REQUIREMENTS. BREAKER TO BE RED OR MARKED RED; CONNECTION BY OTHERS. 6. THE FIRE LITE 92000DLS IS POWER LIMITED ON ALL CIRCUITS EXCEPT BATTERY CONNECTIONS & 120VAC POWER CONNECTIONS. 7. WIRING TO BE OF THE TYPE AND SIZE AS RECOMMENDED BY FIRE LITE WIRING RECOMMENDATIONS IN THE INSTALLATION AND DESIGN MANUAL, AS WELL AS CONFORMING WITH NEC 2011 STANDARDS. 8. NOTIFICATION APPLIANCE CIRCUITS TO BE STYLE (Y) CLASS B. 9. STANDBY POWER CALCULATIONS FOR THE DETECTION SYSTEM REFLECT 24 HOURS. SCOPE OF WORK: THE CONTRACTOR WILL ALTER EXISTING FIRE LITE FIRE ALARM SYSTEM TO ACCOMMODATE NEW TENANT SPACE AS SHOWN ON PLANS. ONE STROBE SHALL BE ADDED AS SHOWN TO PROVIDE ADEQUATE COVERAGE OF ALL COMMON AREAS AND RESTROOM. ALL EXISTING DEVICES ARE NOTED OTHER THAN THE ONES NOT INSTALLED IN THE NEW TENANT SPACE. THEY ARE SHOWN FOR BATTERY CALCULATION PURPOSES AND NOTED AS LIGHT GRAY. ALL HORN STROBES AND STROBES ARE 75CD. G � O' U� �P�J�\yG SCJ I SEQUENCE OF EVENTS MANUAL PULL STATION TROUBLES WATER FLOW TAMPER SWITCH SMOKE DETECTOR FACP 1 92000DLS FIRE LITE NOTIFIER ADDRESSABLE FIRE ALARM CONTROL PANEL © 2 BG-12LX I FIRE LITE ADDRESSABLE MANUAL PULL STATION MIM 2 MMF-100 FIRE LITE ADDRESSABLE MONITOR MODULE CQ 7 1 P2R SYSTEM SENSOR WALL MOUNTED HORN STROBE ® 4 SR SYSTEM SENSOR WALL MOUNTED STROBE � O 1 SUPPLIED BY OTHERS N/A FIRE SPRINKLER VALVE TAMPER / FLOW SWITCH " : Battery 13attery Amin Hrnrr rarr Infinn Standby Load Current Ams Required Standby Time T scall 24 or 60 Hours W 0.065 X 1.56 AH Alarm Load Current Ams Required Alarm Time T scall 5 or 10 Minutes a 3.463 X Fi};, = 0.58 AH CQ Sub Total Standby/ Alarm Am Hours 2.14 AH Multiply by the Der atin Factor X 1.2 " Total Ampere Hours Required — 3 AH J" Derating Factor required to compensate for the non-linear discharge characteristic of a bake w �• / Reviewed . tl Tim R les _w Qlflr ilNr iIMU .,� W z a CQ � � Q Wo4 � � O w 0 �� P34 1 0 n �W� �+ z- CO c' .-. CD � w o � H a y � Q 7 a 11 co 1,4 O Z a � a 0� 1 I� P4 1-4 FIRE ALARM PLAN C� Q, H O H a W A Z o � 5 � w [~ �o N A N Z o CONTRACT # SC -16-00 DRAWN: AW CHECKED: DFPE DATE: 8-23-2016 TOTAL A/S : N/A SCALE: AS NOTED FA - 1