Loading...
HomeMy WebLinkAbout2641 Vineyard Cir (a)® STATE OF FLORIDA CERTIFIED BUILDING CONTRACTOR: D.R. HORTON HOMES 5850 T.G. LEE BLVD. SUITE 600 ORLANDO, FL, 32822 TEL: (407) 850-5200 1 -FOUNDATION FAX: (407) 850-5300 • 2007 FLORIDA FIRE PREVENTION CODE e STATE OF FLORIDA PROFESSIONAL ARCHITECT: JAMES CANTWELL AR NO. 12079 A.B. DESIGN GROUP, INC. 1441 NORTH RONALD REAGAN BLVD. LONGWOOD, FLORIDA 32750 Tel: (407) 774-6078 Fax: (407) 774-4078 ., _i` C V r-�r 'Ire s 11 porton. com 5850 T. G. LEE BLVD. SUITE 600 ORLANDO, FL 32822 Tali (407) 850-5200 Fax: (407) 850-5300 DESIGN CRITERIA: DATE ABBREVIATIONS LUMINOUS MEDICINE CABINET • FLORIDA BUILDING CODE (FBC) 2007 RESIDENTIAL ABV. ABOVE LAV. W/2009 SUPPLEMENT A/C AIRCONDITTONTNG LUM. 1 -FOUNDATION ADJ. ADJUSTABLE M.C. • 2007 FLORIDA FIRE PREVENTION CODE ALT. ALTERNATE MFR. • NATIONAL ELECTRICAL CODE (NEC) — 2008 EDITION All. BD. AMPERAGE BOARD MIN. M.T. • ALL LOCAL AND STATE CODES CL CENTERLINE MTD. PG CAB. CABINET MTL. 3A -ELEVATION CLG. CEILING N.T.S. PAIR CLR. CLEAR O.C. PG CONC. CONCRETE PL DETAILS CPT. CARPET P.B. RETURN AIR GRILL C.T. CERAMIC TILE PH. • OCCUPANCY — RESIDENTIAL, GROUP R3 D. DRYER PLT. • CONSTRUCTION TYPE — VB DBL. DOUBLE P D.G. DUAL GLA7.ED PR. • MIN. INTERIOR FINISH — CLASS B DIA. DIAMETER P.T. • BASIC WIND SPEED — 120 MPH (M/S) DIM. DTSP. DIMENSION DISPOSAL R. RAD. • 1—STORY RESIDENCE — DP. DEEP R.A.G. • 2—STORY RESIDENCE — MAX. HEIGHT AS PER DR. D.S. DOOR DOWNSPOUT REF. RM. LOCAL AND , STATE CODES DTL. DETAIL R.O. SPECIFIC PARAMETERS FROM FBC 2007 CH. 3 D.W. EA. DISHWASHER EACH S.C. S.D. USED FOR DESIGN INCLUDE: ELEV. ELEVATION S.H. • CONCRETE MASONRY RESIDENTIAL EQ. EXH. EQUAL EXHAUST SHT. SHTHG. • CONSTRUCTION WOOD FRAME CONSTRUCTION EXT. EXTERIOR SHWR. • AMERICAN SOCIETY OF CIVIL ENGINEERS 7-05 F.G./FX. F.G. FIXED GLASS FUEL GAS SIM. SL. w Q . F T . CALL . S FIN. FLR. FINS FLOTOR SH STD. T. 'COP OF PLATE FLUOR. FLUORESCENT SWS FR DR. FRENCH DOOR LIVING 1542 SQ. FT. FTG. FOOTING TEMP. UNLESS NOTED GA. GAUGE THK. ENTRY ELEV. 'A" 4 'E3" 14 SQ. FT. GAR. DISP. GARBAGE DISPOSAL T.O.C. G.F.T. GROUND -FAULT CIRCUIT T.O.P. ENTRY ELEV. 'C" 4 'D' 42 SQ. FT. INTERRUPTER T.O.S. GL. GLASS ' TYP. GARAGE 392 SQ. FT. GYP. BD. GYPSUM BOARD U.N.O. WROUGHT IRON H.B. HOSE BIB H.C. HOLLOW CORE V.P. TOTAL ELEV. 'A' E '5' 1948 SQ. FT. HDR. HEADER W. HGT. OR HT HEIGHT W/ TOTAL ELEV. 'C' 4 'D" 1916 50. FT. INSUL. INSULATION WD. INT. INTERIOR WDW. PATIO 35 50. FT. W/H OPT. COV. PATIO 80 5Q. FT. W.T. REVISIONS LAVATORY DATE DESCRIPTION LUMINOUS MEDICINE CABINET 11/3/08 D.R-P 5,48E MODEL CHANGES MANUFACTURER MINIMUM 4/20/09 R.L. REVISIONS - REMOVE "E" 4 "F" ELEVATIONS GN- 1=LUM5-GUT OVERHANGS, RAISE 5RG. PGTS. TO METAL THRESHOLD 1 -FOUNDATION PLAN PG MOUNTED METAL PLAN 6-8" ON "A" 4 11511 ELEVATIONS NOT TO SCALE ON CENTER 1/30/09 REMOVED FRAMING AT A/C CLOSET IN GARAGE PER LOU AVELL I PROPERTY LINE PUSH BUTTON 10/10/09 CHANGED A/C PLATFR0 1 113.2- LINTEL SCHEDULE (PRO -CRETE) PG PHONE PLATE PG 2- FIRST FLOOR PLAN PG 3A -ELEVATION PLYWOOD PG 4A -ELEVATION PAIR PG 5AB- PRESSURE TREATED PG 6 -ELECTRICAL PLAN RISER D1 -FOUNDATION DETAILS RADIUS D2-MISC. DETAILS RETURN AIR GRILL D3 -1 -STORY WALL SECTIONS REFRIGERATOR D4-MISC. DETAILS ROOM D5-MISC. DETAILS �I�c Off 6 ROUGH OPENING SOLID CORE EXT DR SMOKE DETECTOR SINGLE HUNG SHEET SHEATHING SHOWER SIMILAR SLIDING SLIDING GLASS STANDARD SHEAR WALL SECTION TEMPERED GLASS THICK TOP OF CURB 'COP OF PLATE TOP OF SLAB TYPICAL UNLESS NOTED OTHERWISE VAPOR PROOF WASHER WITH WOOD WINDOW WATER HEATER WROUGHT IRON 1 11 t. g yFORO�U1u+'oso H ��ppisNA f - R t? IS ,O E0 pCE. . E p v IFo� pERM%TP, v6c t4sg T�� .ip VtOLof .THE Cpt4SK A A NdpR Sv--r X C�bss to t� KNE WEI , 5 O v"- MIT t'tREVEVIlk, G A G X10 cAl PS vAKC OF p PER ER REQ CONS ,ss ,` FROM �t'EROi3 YNE P 6�C, ,og ��-nOo+S of �N 03 A R C H IT E C T S. ft. 441 N. RONALD REAGAN BLVE LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SUBDIV. 8a LOT: TUSCA SOUTH LOT 41) PROJECT# 1'703.00 MODEL: "1542" GARAGE SWING: RIGHT PAGE: COVER PAGE mmm000 ARCHITECT: STATE OF FLORIDA DL -C 2/ 69 JAMES CANTWELL VA AR NO 12079 DA E: 12/23/09 SCALE:1/499=1 $—of) SHEET c 1 OP'�� INDEX OF DRAWINGS SHEET # DESCRIPTION PG C1 -COVER PAGE PG GN- GENERAL NOTES PG 1 -FOUNDATION PLAN PG 1A -DOWEL PLAN PG iB- LINTEL SCHEDULE (CAST -CRETE) PG 1B.1- LINTEL SCHEDULE (WEKIWA) PG 113.2- LINTEL SCHEDULE (PRO -CRETE) PG 1C -WIND LOAD CALCULATIONS PG 2- FIRST FLOOR PLAN PG 3A -ELEVATION "A" FRONT & REAR PG 4A -ELEVATION "A" LEFT &RIGHT PG 5AB- FRAMING PLAN "A" PG 6 -ELECTRICAL PLAN PG D1 -FOUNDATION DETAILS PG D2-MISC. DETAILS PG D3 -1 -STORY WALL SECTIONS PG D4-MISC. DETAILS PG D5-MISC. DETAILS �I�c Off 6 A R C H IT E C T S. ft. 441 N. RONALD REAGAN BLVE LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SUBDIV. 8a LOT: TUSCA SOUTH LOT 41) PROJECT# 1'703.00 MODEL: "1542" GARAGE SWING: RIGHT PAGE: COVER PAGE mmm000 ARCHITECT: STATE OF FLORIDA DL -C 2/ 69 JAMES CANTWELL VA AR NO 12079 DA E: 12/23/09 SCALE:1/499=1 $—of) SHEET c 1 OP'�� GENERAL NOTES 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE 2007 RESIDENTIAL EDITION OF THE FLORIDA BUILDING CODE (FBC), AND IN CONJUNCTION WITH ASCE 7-05. 2. THE MINIMUM SUPERIMPOSED DESIGN LOADS ARE AS FOLLOWS; A. FLOOR LIVE LOADS (PSF) I. SLEEPING ROOMS 30 II. ATTICS W/ STORAGE 20 III. ATTICS W/OUT STORAGE 10 IV. POOLROOMS 75 V. BALCONIES 60 VI. DECKS 40 VII. STAIRS AND EXIT WAYS 40 VII. ALL OTHER ROOMS 40 B. FLOOR DEAD LOADS 10 (PSF) C. ROOF LIVE LOADS ** I. "MINIMUM ROOF LIVE LOADS SHALL COMPLY WITH TABLE R301.6 OF THE FBC 2007 RESIDENTIAL D. ROOF DEAD LOAD (PSF) I. FIBERGLASS SHINGLES 17 II. CONCRETE TILES 25 E. WIND LOAD CRITERIA I. BASIC WIND SPEED 120 MPH II. WIND IMPORTANCE FACTOR (IW) 1.0 III. EXPOSURE CATEGORY B IV. WIND DIRECTIONALITY FACTOR (KD) 0.85 V. INTERNAL PRESSURE COEFFICIENT (GCPI) OPEN BUILDINGS 0.00 PARTIALLY ENCLOSED BUILDINGS ±0.55 ENCLOSED BUILDINGS ±0.18 F. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, 2007 EDITION. 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK. 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. GARAGES AND CARPORTS 1. GARAGE DOOR A. ENGINEERED FOR 120 MPH MIN. WIND LOAD. B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER 2. AS PER FBC 2007 SECTION R309.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 318 INCHES THICK, OR 20 -MINUTE FIRE -RATED DOORS. 3. AS PER FBC 2007, SECTION R309.1.1: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL 1" MIN. RIGID NON-METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. AS PER FBC 2007 SECTION R309.2: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN %-INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 518 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN'/rINCH GYPSUM BOARD OR EQUIVALENT. SITE WORK 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS. 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON-SITE UTILITIES, SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATION. 3. PRESUMPTIVE SOIL BEARING CAPACITY IS 2000 PSF ON UNDISTURBED SOIL. ALL CONCRETE FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR ENGINEERED FILL. BOTTOMS OF FOOTINGS SHALL BE 1'- 0" BELOW FINISH GRADE (MIN.). 4. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT. 5. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN'/2THE HORIZONTAL DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. 6. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8" LAYERS AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. 7. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. 8. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 9. EXCAVATIONS TO BE A MINIMUM OF 3'- 0" BEYOND NEW FOOTING LINE. 10. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS. 11. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, LINO. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES. 12. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWINGS. CONCRETE 1. ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE IN BUILDINGS, ACI 301, AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318. 2. ALL CONCRETE FOR THE FOOTINGS, SLABS ON GROUND, AND MISCELLANEOUS ITEMS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AFTER 28 DAYS, UNLESS NOTED OTHERWISE ON THE DRAWINGS. 3. ALL AGGREGATES USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE'/4'. 4. PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER. 5. BRACE FOUNDATION WALLS, RETAINING WALLS, DURING BACKFILLING AND TAMPING OPERATIONS. LEAVE BRACING IN POSITION UNTIL PERMANENT RESTRAINTS ARE INSTALLED. 6. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED'/4'. 7. PROVIDE 6 -MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE. 8. CONTRACTOR/OWNER TO PROVIDE SOIL REPORT TO ARCHITECT PRIOR TO ANY CONSTRUCTION.. MASONRY 1. DESIGN MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES, ACI 530.1 / ASCE 6, LATEST REVISION. 2. CONCRETE MASONRY UNITS SHALL BE GRADE "N" TYPE II OR EQUAL AND, IN ACCORDANCE WITH ASTM C90, STANDARD SPECIFICATIONS FOR HOLLOW LOAD-BEARING CONCRETE MASONRY UNITS, MINIMUM COMPRESSIVE STRENGTH OF Pm =1500 PSI. 3. OPEN-END BLOCK MAY BE SUBSTITUTED FOR STANDARD TWO CELLED BLOCK. 4. MORTAR SHALL BE TYPE M OR S IN ACCORDANCE WITH ASTM C270, STANDARD SPECIFICATIONS FOR MORTAR FOR MASONRY. 5. MORTAR JOINTS FOR ALL BED AND HEAD JOINTS ARE TO BE 3/8 INCH THICK. THE BED JOINT OF THE STARTING COURSE MAY VARY BUT IT SHALL NOT BE LESS THAN'/ INCH AND NOT MORE THAN 3/ INCH, REFER TO FBC 2007, SECTION R607.2.1.1 FOR MORTAR JOINT THICKNESS TOLERANCES. 6. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476, STANDARD SPECIFICATIONS FOR GROUT FOR MASONRY, OR 3000 PSI PEA ROCK CONCRETE PER SPECIFICATIONS. 7. FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING. 8. MASONRY WALLS SHALL BE LAID IN A RUNNING BOND PATTERN OR, IF A STACK BOND PATTERN IS TO BE USED 9 GA. HORIZONTAL JOINT REINFORCEMENT; FOR 24" IN ALL DIRECTIONS, IS TO BE INSTALLED IN THE BED JOINTS SPACED AT 16" ON CENTER (MAX). REINFORCING STEEL 1. ALL CONCRETE AND MASONRY STEEL REINFORCEMENTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES, ACI 315; THE STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS, ACI 301; AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318. 2. REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE CONFORMING TO ASTM A615, GRADE 40 (UNO). 3. WELDED WIRE FABRIC SHALL BE 6" X 6" - W1.4 X W1.4 AND SUPPLIED IN FLAT SHEETS CONFORMING TO ASTM A185. LAP SIDES AND ENDS A MINIMUM OF 12". LOCATE WWF 2" FROM THE TOP OF THE SLAB, UNLESS OTHERWISE NOTED ON THE PLANS. THIS REINFORCEMENT SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 3'-0".FRCR506.24(2) 4. ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE WALL, WITH LAP SPLICES OF AT LEAST 25". 5. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES AT LEAST 25" WHEREVER POSSIBLE. 6. CLEARANCE OF MAIN REINFORCING BARS FROM ADJACENT CONCRETE SURFACES SHALL BE: A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B. CONCRETE EXPOSED TO EARTH OR WEATHER: I. #5, W31 OR D31 AND SMALLER 2" C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: I. #11 AND SMALLER 3/4' D. BEAMS, COLUMNS: L PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS1'/2" 7. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS WITHOUT THE APPROVAL OF THE ARCHITECT. TIMBER 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) B. NATIONAL FOREST PRODUCTS ASSOCIATION: I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION C. SOUTHERN PINE INSPECTION BUREAU: I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER D. TRUSS PLATE INSTITUTE: I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI -2002) E. APA - THE ENGINEERED WOOD ASSOCIATION: I. ENGINEERED WOOD CONSTRUCTION GUIDE F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 2. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN PINE #2 (MIN.) STRESS GRADE LUMBER, UNO. Fb =1,500 PSI Fv =175 PSI E =1,600,000 PSI STRUCTURAL LUMBER SHALL CONSIST OF, BUT NOT LIMITED TO; RAFTERS, VERTICAL STRONGBACKS, LEDGERS, BEAMS, HEADERS, AND POSTS. 3. LUMBER FOR INTERIOR BEARING WALLS OR EXTERIOR WALLS SHALL BE STUD GRADE SPRUCE PINE FIR OR BETTER (UNLESS NOTED OTHERWISE). 4. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. 5. MINIMUM NAILING PER 2007 FLORIDA BUILDING CODE, SEE TYPICAL NAILING SCHEDULE ON PLANS. 6. ALL BOLTS SHALL HAVE MINIMUM 2" SQUARE STANDARD CUT WASHERS UNDER HEADS AND/OR NUTS WHERE IN CONTACT WITH WOOD. 7. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL CONFORM TO FBC 2007.. 8. FOR ASPHALT SHINGLE ROOFS, SHEATHING SHALL BE APA RATED 7/16" OSB EXPOSURE -1 OR 112" CDX PLYWOOD SHEATHING. PROVIDE PANEL -CLIPS AT MID -SPAN FOR SPANS GREATER THAN 16" ON CENTER AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING. 9. FOR CEMENTITIOUS TILE ROOFS, SHEATHING SHALL BE APA RATED 518" OSB EXPOSURE -1 OR 1/2" CDX PLYWOOD. 1/2" CDX SHEATHING SHALL BE INSTALLED WITH THE STRENGTH AXIS RUNNING PERPENDICULAR TO THE TRUSSES AND SHALL SPAN A MINIMUM OF TWO TRUSS BAYS. PROVIDE PANEL -CLIPS AT MID -SPAN FOR SPANS GREATER THAN 16" ON CENTER AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING. 10. FLOOR SHEATHING SHALL BE APA RATED 3/" SUBFLOOR T & G INTERIOR PLYWOOD, GLUED AND NAILED. ADHESIVES CONFORMING WITH PERFORMANCE SPECIFICATION AFG-01 SHALL ONLY BE USED. 11. WALL SHEATHING SHALL BE APA RATED 7/16" OSB EXPOSURE -1 OR 1/2" CDX PLYWOOD SHEATHING. 12. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SQ. 13. PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND COLUMNS WITH 2x STRUCTURAL LUMBER SYP #2. 14. TRUSS MANUFACTURER SHALL PROVIDE COMPLETE CALCULATIONS SHOWING INTERNAL LAYOUT, MEMBER FORCES AND STRESS CONTROL POINTS AND SUBMIT TO THE BUILDING DEPARTMENT FOR APPROVAL AND TO THE STRUCTURAL ENGINEER FOR REVIEW. ALL CALCULATIONS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROPOSED CONSTRUCTION. 15. TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982. 16. PREFABRICATED TRUSS TOP AND BOTTOM CHORD LOADS SHALL BE PER THE RECOMMENDED MINIMUM DESIGN LOADS IN APPENDIX B OF THE ANSI/TPI 1-2002 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO U360. DEAD PLUS LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO L/240. 17. THE CONNECTIONS FOR ALL TIMBER EXPOSED TO EXTERIOR ELEMENTS OR TO PRESSURE TRATED LUMBER SHALL BE GALVANIZED OR PAINTED WITH A CORROSION RESISTANT POLYMER PAINT. 18. ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "SIMPSON" STRONG -TIE BY SIMPSON CO., OR EQUAL. UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH THE SIZE AND NUMBER OF BOLTSINAILS AS RECOMMENDED BY THE MANUFACTURER IN THE LATEST CATALOG. PLUMBING 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. 2. WATER SUPPLY LINES SHALL BE CPVC. 3. CONDENSATION LINES SHALL BE MINIMUM 3/" PVC (SCHEDULE 40), INSULATED WITH %" AMAFLEX. 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO THE 2007 FLORIDA BUILDING CODE. 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO THE 2007 FLORIDA BUILDING CODE. 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. EXTERIOR FINISHES 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, 8" THICK, OVER FRAMED WALLS APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN TWO COATS, Y2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM -C926 2 -STORY GYPSUM BOARD UNDER STAIR PROTECTION: 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. FBCR 311.2. A R C H I T E C T S Desi n OU Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 StMDIV. & LOT: TUSCA SOUTH LOT #41 PROJECT# 1'703.00 MODEL: "1542" GARAGE SWING: RIGHT PAGE: ARCHITECT* STATE OF FLORIDA DEC 2009 JAM S ANTWELL AR NO 12079 DATE: 12/23/09 SCALE: 1/4"=1'-0" SHEET oF1� ,.top_ �sy 16'-1111 II_�II IroI_1N 1 4' CONC. SLAB. 110 D1 I iL (10 I D1 -31/2" pl HB. EXTEND I I pl SLAB 11/2' ■ D1 I 01-m" ELEV. D1 ■ FIN. GONG. 5LA5 � I N O 4" CONC. REINFORCED 1 W/6'X6" WIA X WI.4 WWM I ■ pj OR FIBERMESH ON 6 -MIL. VAPOR BARRIER ON ■ WELL -COMPACTED I CLEAN TERMITE TREATED FILL OR APPROVED SUBSTITUTE, _ �- — -� (RECRUIT 11 SYSTEM) 0 I I I \ `I LAY. /% wc. -- I3 I �, ■I Al `J1 LAV. ISN I I m I I^ 2x6 WALL Cv 2'-io" • -� O F l ■ II Q I w 0Io-,I 1 0 I — UOO z x6 W,dL�C Q N I m'—m" ELEV. 1 n FIN. CONC. SLAB I IL I ■ 07-40 N 4" P.Y.C. ' w Z3O D l SLAB IDl/2" I__ CHASE D I Q w EXTEND uad) U 1n 5LA5 1 1/z" ClI I r X= O 04 I I I O I �t WL) U L) d) Jam- ■ I 1811 3'_4" 811 I I D I a p II LH. / 7_7 I D I @ -51/2" " - 2'-5" ■ 2" STEEL cf) 2'—m3'-�" PIPE " BOLLARD 4'-2" L, 3'-0" 3'-611 gl_011 6, D m I I0 -4 1/2" 1 Lu 6, p o 41 I , 0 I N GONG. I I I L — —SLAB_j , I 1 D -"11/2" I ■■_F7 I ■■ 12'-0' 41-a" 41-811 I_411 W_oII I_4N 21'-4" V 401-011 FOUNDATION 99 99 1D 99 ■ ■ 5 -5° 101_011 24'x24"x12" CONC. PAD W/ 3 -*5 BARS E.W. ON CI-IAIRS MIN. 3' COVER 4 4 Di 411 CONC. (1_ SLAB. O —3 1/2" N 0'-0' ELEv. FIN. CONC. SLAB EXTEND 5LA5 1 1/2" ■ \-4" �t GONG. SLAB ELEV . 99 C 99 & ' 9 SECURE STRAP TO CONC. W/ (2)-3/16"X2' TAP—CONS GONG. SLAB UNIT SIMPSON WB UNIT STRAP OR EQUAL SECURE STRAP TO UNIT W/ (2) #8x1 1/4 SHT MTL SCREWS A/C CONNECTION 1'0 PAD DETAIL A R C H I T E C T S -1 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SXMDIV. & LOT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 MODEL: 1542 GARAGE SWING: RIGHT PAGE: FOUNDATIO PLAN ARCHITECT - STATE OF FLORIDA DATE: 12/23/09 SCALE: 1/4"=1'-0" SHEET OF b c !:k�AI-rkll DOWEL PLAN ELEVATIOr '411k, I I --1 i ELEVATION "C" & "D" I A R C H I T E C T 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SUHDIV. & LOT: TUSCA SOUTH LOT X41 PROJECT# 1703.00 MODEL. "1542" GARAGE SWING: RIGHT PAGE: DOWEL PLAN ARCHITECT - STATE OF FLORIDA Crc 2009 JA E`C�4NTWELL R NO 12079 DATE: 12/23/09 SCALE:1/4 11 =1' — 0" SHEET IA OF 16 0 _ I SAFE LOAD TABLES FOR GRAVITY, UPLIFT & LATERAL LOADS 1 8" PRECAST & PRESTRESSED U -LINTELS 8" PRECAST & PRESTRESSED U -LINTELS LiNTEL NO. LENGTH GRAVITY UPLIFT COMMENTS LATERAL TYPE LENGTH SUa eF6-08 cru -m5 16-m m-0 4- a -m 32-m eFa-15 8F12-18 81=16-113 15MV- W24-115 8F28 -I13 SF32-15 V-10'(349 PRECAST 2302 3166 4413 6039 1526 W04 10412 11936 3166 4413 6039 1526 9004 10412 11936 3'-6' (42') PRECAST 2302 3138 3311 4689 6001 1315 8630 9941 3166 4413 6039 1526 9004 10412 11936 4'-0'(48') PRECAST 2029 2325 24% 3461 4438 5410 6384 1358 2646 4413 6039 1526 9004 10412 11936 4'-6' (54') PRECAST 1651 1181 1913 2651 3403 4149 4896 1660 2110 4021 6039 1526 9004 10412 5'-4' (64') PRECAST 1184 1223 1301 1909 231'1 2826 3336 q 1665 2889 5051 6096 5400 6424 5'-10'(70') PRECAST 912 1000 1059 1414 1889 2304 2121 3131 1459 2464 4144 5458 4431 5280 6122 PRECAST 937 1255 2101 3263 2146 3358 3911 4585 1255 2101 3396 5260 1134 8995 6890 l'-6" 190') PRECAST l6i 1029 1615 2385 1994 2439 2886 3333 1029 1675 2610 3039 5596 6613 5041 9'-4' (112') PRECAST 5-13 632 1049 1469 1210 1482 1'154 2021 168 1212 1810 2544 3469 4030 3121 10'-bY126') PRECAST 456 482 802 1125 915 1122 1328 1535 658 1025 1514 2081 2114 3130 2404 11'-4' (136') PRECAST 445 598 935 1365 1854 2355 1193 2015 598 935 1365 1854 2441 3155 4044 12'-0'(144') PRECAST 414 545 864 1254 1689 2014 1510 1818 555 864 1254 1693 2211 2832 3590 13'-4' (1609 PRECAST 362 421 126 1028 1331 1635 1224 1418 485 148 1016 1438 1855 2343 2920 14'-0'(168') PRECAST 338 361 648 919 1190 1462 1081 1260 455 100 1003 1335 1114 2153 2666 PRESTRESSED NR NR NR NR NR NR NR NR 465 165 1310 2045 2610 3185 3165 15'-4' C184'J PRESTRESSED N.R NR NR NR NR NR NR NR 420 695 1250 1855 2310 2890 3410 ll' -4' CZ08')PRESTRl=55ED NR NR NR NR NR NR NR NR 310 530 950 1400 1 1800 2200 2600 IV -4'(2S29 PRESTRESSED N R NR NR NR NR NR NR NR 240 400 150 1090 1400 1120 2030 21'-4" (256') PRESTRESSED N R NR NR NR NR NR NR NR 183 330 1 610 940 1340 1180 2110 22'-O'0649PRESTRESSED NR NR NR NR NR NR NR NR 160 300 510 010 1250 1660 1910 24'-0Y288') FRE N.R NR NR NR NR NR NR NR 130 240 410 120 1030 1350 1610 8" PRECAST & PRESTRESSED U -LINTELS 0F4=_WU1.M VALUG GT JVD MGM WrRf r- ' ri "W R" PRPrACT w/ 9" RF(:FSS DOOR U -LINTELS R� LiNTEL NO. LENGTH UPLIFT UPLIFT COMMENTS LATERAL LATERAL tYP LENGTH 0 - 8F8 -I 12 -IT I6 -IT 20-1P4532 BRF26-IT 8-I 8F32-17 2982 8F8 12-2 16-2 20-2 4_:218-2 84=32-2!8UB 2'-10'(34') PRECAST 2121 2818 4101 5332 4'-6' (54') PRECAST 1811 9055 2021 2021 2121 2184 3981 5190 1630 8851 3'-6' (42') PRECAST 2165 2289 3260 42316204 5'-8' C68") PRECAST 185 1192 1251 1251 2165 2215 3165 4125 6061 1036 4'-0' (48') PRECAST 1818 1989 2832 3680 5'-10' (l0'J PRECAST 5381 6245 938 938 1818 1925 2150 3583 4422 5264 6110 4'-&'(54') PRECAST 1660 1162 2501 3251 4010 4161 5525 121 121 1660 1105 2435 3111 3913 4658 5406 5'-4' (64') PRECAST 1393• 13S311431 1484 2110 2050 2141 2610 3315 3293 4010 3920 4648 4549 505 505 5'-10'(70') PRECAST 1212• 1351 1930 2505 3084 3665 4241 418 418 1212 1 1315 1815 2441 3010 3583 4151 6'-6' (l8") PRECAST 1141• 11200 1 1011 1133 2250 2169 3290 3812 101 Sal 1141 1 1182 1684 2192 2103 3216 3132 1'-6" C90')PRECAST 959• 990 912 1029 1415 1466 1914 1901 2354 2351 2191 2191 3240 3245 591 65-1 9'-4' (1129 PRECAST 001-1 801 612 155 950 1192 1269 1550 1560 1910 1852 2211 2144 2634 454 630 10'-6Y1269 PRECAST 116• 498 193 1021 1261 1496 1131 3% 493 116 611 1039 1389 77 2034 2358 11'-4' (1369 PRECAST 666• 439 696 899 1104 1309 1515 363 556 666 535 905 1295 1595 1896 2198 12'-0'(144') PRECAST 601• 400 631 816 1001 1186 1312 340 494 631 486 818 1209 1514 1199 2086 13'-4'(160') PRECAST 500• 340 532 686 B41 991 1153 302 398 513 409 682 1004 1361 1631 1891 14'-0'(168') PRECAST 458• 316 493 635 118 922 1065 286 360 548 315 629 922 1254 1561 1816 1611 14'-8' mw) PRESTRESSED 243 295 459 591 124 851 990 N.R. 351 24-3-r352 582 852 1156 1491 1142 W-4"(1849 PRESTRESSED 2213 218 430 553 801 925 N,R 321 228 329 542 191 1012 1381 1616 Il' -4' (20B')FR1 STRESSED 188 236 361 464 561 610 114 N.R.1255 188 216 449 649 814 1121 1389 19'-4' 0232') PRESTRESSED 165 201 313 401 490 518 661 N R 204 1651 239 383 1 550 136 940 1160 21'-4' (25691OFMSTRESSED 145 186 218 1 3N6 433 512 590 N.R. 112 142 212 336 411 639 801 993 22'-O'(264')i'RESTRESSED 140 180 268 343 418 493 568 N.R 161 41 131 205 322 45l 601 111L'T2 24'-0'(286') PRESTRESSED 121 165 244 312 300 441515 N.R 135 124 186 290 408 538 68033 0F4=_WU1.M VALUG GT JVD MGM WrRf r- ' ri "W R" PRPrACT w/ 9" RF(:FSS DOOR U -LINTELS R� LiNTEL NO. LENGTH UPLIFT GRAVITY COMMENTS LATERAL TYPE TYPE LENCsTH SWO-iT - era 1m -me 61IFI4- 16-0 6W22- ff"6- gRF6-iB WFIO-IB ORF14-1B DWID-15 81 22 -IB BF1726-IB 61 30-m5 8RF30413 4'-4' (52'J PRECAST BRF26-IT 1591 3053 2982 3954 4929 5904 6880 1489 1821 3412 4982 6412 1941 9416 10818 4'-6' (54') PRECAST 1351 1449 2182 2114 3600 4401 5315 6264 1102 3412 4982 6412 1941 9416 10616 5'-8' C68") PRECAST 185 832 1602 1550 2058 2566 3015 3585 1153 2162 4014 6412 6516 5614 6839 5'-10' (l0'J PRECAST 135 119 1500 1449 1924 2400 2816 3352 1103 2051 3811 6412 6516 5450 6411 (SOI)PRECAST 901 1611 2933 2516 3223 3812 4522 822 90l 1611 2933 4100 6130 Bill 6101 1'-6' (90') PRECAST '16'1311 924• 2252 1958 2451 2944 3439 665 164 1311 2329 9609 5492 6624 5132 9'-$' (116') QR>=CAST gll 420 834 1 1253 1 1011 1342 1 1614 1886 535 928 1 1491 1 2119 2618 1 3595 2815 R" PPrnAST w/ 2" RECESS DOOR U -LINTELS .�. LiNTEL NO. LENGTH UPLIFT TYPE ELEV. 'C" 4 COMMENTS LATERAL TYPE 91Wb-IT SWO-iT BFF14-iT 8RFI8-IT DW22-IT BRF26-IT OW30-1 ea LENCsTI-I BRU SRF 80*6-2T SWIO-2 OW4-2T 9W18 -2T VW22-2T e1M26- 30-2- 4'-4* (52') PRECAST 1244 1513 2413 3260 4112 4961 5825 932 932 1244 1519 2339 3110 4008 4850 5696 BF24-M/1T SF32-05/1T 8' L 8 1192 1501 2311 3931 4156 5511 BF16-05/1T 4'-6' (549 PRECAST _3121 853 853 1192 1455 2240 1 3036 3831 1 4643 5453 924• 1112 1195 2423 3055 3689 4325 5'-8' 168') PRECAST 501 501 924 1132 1141 2351 2918 3603 4230 896• 1138 1142 2352 2965 3581 4198 5'-10' (l0') PRECAST 469 469 896 1099 1690 2288 2891 3491 4106 lie 582 1513 2042 2513 3101 3642 6'-8' (80')PR>=CAST 830 1100 118 956 1468 1981 2509 3035 3563 flee 691 1325 IB10 2280 2153 3221 110 941 688 849 1302 1162 2225 2690 3151 1'-6' (90') PRECAST 9'-8' (1169 PRECAST533• 433 808 1123 1413 1104 1995 516 614 533 1-5 21 1009 1369 1128 2088 2450 -i-w-VUVG THL 6 I I I -VI-.- -.1(/ 1 ­ lam... r+ -n_ PATIO L-6 L- 9 L- 6 25 -SH 25 -SH L'- 7 25 -SH EGRESS EGRESS EGRESS 5068 SJG.D. OWNERS BDRM. 3 ■ SUITE FAMILY S'-s' CLG. ROOM V-8' CLG. II--------- II BATH #2 II a�o I I 0. ,� =7' C� ■ BATH i V-8' CLG. �� O O I ■ I i I KITCHENI0 W.I.C. p SD8 M LG L------- I f N I r FOYER 1 1 I I w 8'-S" CLC. I I I I I I II I _ _ 8Ug " I i I A LIVING ROOM/ II CLG. I I -------- --- L_ -J DINING ROOM/ BRKFST I ■ OPT. BEDRROOM #4 8'-a" CLG. I I 1 0 ■ ■ 35-614 W/ L-3 ,4RCH TOP L-1 GARAGE ELEVATTnN "A" k. ""R V-8' BEARING HEIGHT THROUGH OUT ELEVATION 'A' k "B" -------------------- - - - - - - - - - - - - - - - - - - - 16'-O'X1I-0"O.H.D. L- 4 CAST -CRETE I,INTEIL MATERIALS I. f'c precast Ifntele ■ 3500 pal. 2. Fc prestressed lintels ■ 6000 pei. 3. f,c grout ■ 3000 psi w/ maximum 3/8' aggregate. 4. Concrete masonry units (CMU) per ASTM C90 w/ minimum not area compressive strength • 1900 psl. 5. Rebar provided in precast lintel per ASTM A615 GR60. Held rebar per ASTM A615 GR40 or &R60. 6. Prestressing strand per ASTM A416 grade 210 low relaxation. 1. 1/32 wire per ASTM A510. 8. Mortar per ASTM C210 type M or S. GENERAL NOTES I. Provide full mortar head and bed joints. 2. Shore Filled lintels as required. 3. Installation of lintel must comply with the architectural and/or structural drawings. 4. Lintels are manufactured with 5-1/2' long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. All lintels most or exceed 1_/360 vertical deflection, except Ilntels 1l'-4' and longer with a nominal height or 8' meet or exceed L/180. f the lintel cavity . e ar to be located et the bottom o &. Bottom m field added r b B y 1. 1/32' dfameter wire stirrups are welded to the bottom steel For mechanical anchorage. 8. Cast -in-place concrete may be provided in composite lintel in lieu of concrete masonry unite. S. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 SCHEDULE SAFE LOAD TAB1_E NOTE5 '. •y .y SRF14-05/7 SF16-�5/1T ','`fir.?.'%• .fi ; ••.. •,I'.; ."+.• •ir;•i �, • • •:rpt �. SF16 -15/1T SRP30-m5/1T OF-32-05/IT SF32 -15AT 44MzTM.C4$g4E 4C LINTEL SCHEDULE LiNTEL NO. LENGTH T1'PE ELEV. "A' 4"5" TYPE ELEV. 'C" 4 COMMENTS L 1 5'-4' BRF14-05/1T OFFF14-05/1T L 2 4'-6' 55F22-05AT 8W30 -05/1T L 3 3'-0 8F24 -05/1T 81=16-05/7 L 4 I'1'-4' SF28-15/IT BF36-15AT L 5 4'-6' BF24-08/1T 81=16-05/1T - L 6 4'-6' 8F24 -05/1T BF16-05/IT 1- 1 6'-0 BF24-M/1T SF32-05/1T 8' L 8 4'-6' 8F24 -05/1T 8:16-05/IT L S 4'_6' 81=24-05/1T BF16-05/1T LIVING ROOM/ DINING ROOM/ OPT. BEDRROOM #4 9'-4" CLG. -SH W/ H TOP E LE VAT I ON 9'-4' BEARING HEIGHT TH ELEVATION "C" 4 V" 1. All values based on minimum 4' bearing. Exception: Safe loads for unrilled TYPE DESIGNATION lintels must be reduced by 20% if bearing length is lose than 6-1/2'. Safe loads for all recessed lintels based on 6' nominal bearing. F ■ FILLED WITH GROUT / U ■ UNFILLED 2. N.R . Not Rated. QUANTITY OF 05 RE5AR AT 3. Safe loads are total superimposed allowable load on the section specified. F BOTTOM OF LINTEL CAVITY 4. Safe loads based on grade 40 or grade 60 field rebar. 5. Additional lateral load capacity can be obtained by the designer by providing addional reinforced masonry above the precast lintel. 8, - 15/1 T 6. "T y Dna rebar may be substituted for two 5 rebore In 8A lintels only. load tables b 1. The designer may evaluate concentrated loads from the safe l Npl-1MA1- WiDtN� QUANTITY 01= 03 calculating the maximum resisting moment and shear at d -away from the Face or eupport. J 8. For composite lintel heighte not shown, use safe load from next lower height. NOMINAL HEIGNt RE5AR At TOP % All safe loads 1n units of pounds per linear foot. 9SC9' - I ___, j & 99D99 A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SLTSDIV. & LOT: TUSCA SOUTH LST #41 PROJECT# 1703.00 MODEL: „1542" GARAGE SWMGi•: RIGHT PAGE: LINTEL SCHEDULE (CAST -CRETE) ARCHITECT: Dr.'s PIA 2009 NO 12/23/09 SCALE: 1/4"=1'-0" SHEET I I'D Or 16 "5 M15AR AT TOP MIN. (1) REQ'D 1-1/2' CLEAR C.M.U. GROUT �p • '' S RE5AR AT BOTTOM - •• OF LINTEL CAVITY L E 5OTTOM REINFORCING 1.5/8'AGTUAL PROVIDED M LINTEL NOMINAL WIDtN 8' (VARIES) A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SLTSDIV. & LOT: TUSCA SOUTH LST #41 PROJECT# 1703.00 MODEL: „1542" GARAGE SWMGi•: RIGHT PAGE: LINTEL SCHEDULE (CAST -CRETE) ARCHITECT: Dr.'s PIA 2009 NO 12/23/09 SCALE: 1/4"=1'-0" SHEET I I'D Or 16 UJB < I UJA CONCRETE I 4101../ trfC I V/ INC.- P.O. BOX 219 ZELLWOOD, FL 32798 (401) 886-2511 1-800-654-5139 FAX 401-886-0195 LINTEL NO. LENGTH TYPE ELEV. 11,41 40511ELEV. TYPE � 11V D COMMENTS L-1 5'-4' 8/14-5-IU/0L S/14-5-IU/0L RECESSED L-2 4'-6' 8/22-6-IU/OL 8/30-S-IU/0L RECE55ED L-3 3'-6" 8/24-5-1U/0L 8/16-S-1U/0L 00 L-4 �-E, 8/28-5-1UAL 8/36-5-1UAL � L-5 4'-6' 8/24-5-1U/0L 8/16-5-1U/0L ®®�l'711:' L-6 4'-6' 8/24-S-1U/0L 8/16-6-1U/0L 10000 L-� 6'-6' 8/24-5-1U/OL 8/32-6-IU/01- /32-S-IU/OLL-8 ��Jlld• L-8 4'-6' 8/24-6-1U/01- 8/16-6-1U/0L ����i��l--k�-'�Ef L-9 4'-6' 8/24-5-1U/01L 8/16-5-1U/0L 10000 LIVING ROOM/ DINING ROOM/ OPT. BEDRROOM #4 9'-4" CLG. H I I FOYER V- 4' GLG. I I I I II II u 3A II EGRESS EGRESS OWNERS SUITE 0. BATH LIVING ROOM DINING ROOM/ OPT. BEDRROOM #4 8'-S" CLC. BRKFST --- V-4" GLG. L— 2 IH5-SH ENTRY L-3 35-9H W/ 9'-4' GLG. ARCH TOP L-1 LIEVATION 99 C99 & 991599 CJ'10-1 - ELEVATION "G" ¢ 'D" 35 -SH W/ ARCH TOP L-1 a� FAMILY ROOM BDRM. 3 BATH 2 e II II I I \\ i KITCHEN I� BDRM. 2 - S -S GLG. Q S'-8' CLG. I N p L— 5 --T�I I I I Nw I II LAUN. r---1 GLC. I I-------- L__J e ELEVATION "A" & "B" 8'-8" BEARING HEIGHT THROUGH OUT ELEVATION 'A' 4 'B" GARAGE 8'-8 GLG. — — — — — — — — — — — — — — — — — — — — 16' L— 4 8" LINTEL UPLIFT N!2 . Not Recommended 12" LINTEL GRAVITY 859 LINTEL GRAVITY LINTEL LINTEL SAF=E LATE=RAL LOADS (PLF) SAFE GRAVITY LOADS (PLF) Type SAFE GRAVITY LOADS ®KK3171 TYPE f -3T]5.18 8/8 -S -0L 8/12 -5 -OL 8/16 -S -0L 8/20-8-0 n M n8-5-0 8/32 -8 -OL SM �t PRECAST :971• t•rr.%r,-•..••.Zt�,...•r.•..•rJ a r r r i i �irR i�ru"r� .:;.. �r/.n...1�%.,•,•,•.lin..%..%:,.1 0 •r ... 00 0000 �-E, a:;:�/,��r/.l/rl/rl.� ../r-,, a%r,•,r.%r,%.��r.-.•.�arl',•,.fi 0000 � 10000 1X7 ft �ck1':>•��-rJl:>•NERrrlul.'.l ]' kt• del♦ a/iu%i �rM, WMI o r%i%r rlry �ru,'vuJ�r.2..l�rol.11.J• NERPlalrPiA ®®�l'711:' 9339 !•7%TIl:'�%T/I�.�%�Sr,*.tr' .�%i- 1•1♦�.rl�__r//%I%I%r1 _�/%I %A_r,,:w /rte_�% //.%I.•%1 �ri� I /I/r)_r,rorw­ _•/11111!11 10000 0000 motLu• _ecce/b =—NO 1rLLm 0111111111M.-im�:'.YP.)•�rr%r.%i uJmmia"1r1r1 ��r�lrl,lrlerr;r-•i5rl�fr,•i'i%il�fr;iv,-ol�r�lulrIr� 4'-0' ��Jlld• 1821 25121 a=zra0� �S:!oYf r • � r!a' •r,-ol �fe'/i.%e%il seems _0,0 Irl/iId/ice ����i��l--k�-'�Ef 10000 �f-1ii.l•��' 10l r]• ���.�W!:� �%}:%il%7�I:f „w��•�Y1/i1�=v/���%/.'i'r•rJ�f :%e' rl�f�lrlrlrl f.'1• 10000 4'-&' PRECAST NOME 2214 5018 1119 �r,3:yaantr Nowifli �.i r <Zfll•�Irs xs� rir 10000 2214 5412 10000 10000 10000 10000 ��� `[ rr:� a ns.�1 � a arra �•t.7..� mfr.:-� �s x:91• �_ i%k5�•1• �4�x1! t 91:Ya �7I:Y� �WYt=� � Yc f.3• `%�iC]� �� 2111 ! r/cY��lN���Yif:1•�f:!vX�mmwxY/:"MONE}:1, 8520 10000 10000 Y �':5:1��1.771:1•�S•Y7��.7rYfol�TrY.l��f�'?r� 10000 �� PRECAST '?r �:fl��'nr;.�;�arxf;�■�f:1.7:t•if(:f•7�.'s.7r1� 3409 4823 6239 =iwI�I'i:ril�'S:l�Y1:Y1•�fo}q:� 9011 tfLft• _ 10000 5'-10' •mom=7�L1'l�l�l:�l4.1o�1��f�:•'%f�S%S=K>• 848 1461 3001 �j,]��t:kr��wrkl•�f%Yl:>•�Ylr� �ItKkt• aW]rrr� 10000 10000 ��'���■�f��zf��zri��f,YY��rIr��G:I�I �� �%a ;� � rYJ:� � r f rJ � �(ria�l, �L S:'al • �4:k•6� ®�Sl:!'! 110 1232 �f,�lrc:� �GlCf��L%Yl��fL-'1%��•.�L-! 3934 ���e•'o��k!:��.'v-'r.%S�'YP.��f?Sl♦�:x11��rol:!:� 8589 �%�a /r "/� r awYz>•�I��-?ate-r:��' , r 10000 1-b' PRECAST 56Z 1001 1918 2942 ���� �Sfr>• �-i'1'>> 1777 �➢i• E3� � IIl-� 10000 1001 1918 2942 4346 6461 10000 iitl� �T<Y� �i:y� �!�)• ter)• ��x� iGi� �-7'Yf• � F.L! � r�Yl � � Y1-1 � � Gi 7� � 'ifs � r i Pf• 544 915 1049 2819 4131 6010 9245 10000 915 049 2819 4131 6010 9245 10000 � PRECASt 511 C'lt lIwillm m IIIINIIIIIIIII 0280 2602 3151 5030 1958 10000 Mom�R 10000 B'-4' -sesswI..lFum�_LI��_'r%�iILT���G�� 482 N!2 . Not Recommended 12" LINTEL GRAVITY 859 LINTEL GRAVITY LINTEL LINTEL SAF=E LATE=RAL LOADS (PLF) SAFE GRAVITY LOADS (PLF) Type SAFE GRAVITY LOADS TOTAL L�TIGT TYPE B" PLAIN 8/8 -S -0L 8/12 -5 -OL 8/16 -S -0L 8/20-8-0 5n4 -5-0L n8-5-0 8/32 -8 -OL 0/8-8-1L 8/12-8-1L206-8-11- SnO-s-IL 0/24 -6 -IL 0/213-8-11- 8/32 -S -IL V-10' PRECAST 6071 ... ® Ora 00 0000 0000 4.6' 0000 8491 10000 10000 10000 10000 10000 10000 3'-6' PRECAST 2603 4011 9339 0000 10000 10000 10000 0000 4011 10000 10000 10000 100001 10000 10000 4'-0' PRECAST 1821 25121 6133 9515 10000 10000 10000 10000 2921 1853 10000 10000 10000 10000 10000 4'-&' PRECAST 1398 2214 5018 1119 9284 10000 10000 10000 2214 5412 10000 10000 10000 10000 10000 4'-B' PRECAST 1298 2111 4660 6588 8520 10000 10000 10000 2111 4902 10000 10000 10000 10000 10000 5'-4' PRECAST 1006 1651 3409 4823 6239 1658 9011 10000 1651 3556 6431 10000 10000 10000 10000 5'-10' PRECAST 848 1461 3001 5111 8888 10000 10000 10000 1461 1 3001 5111 8888 10000 10000 10000 b' -b' PRECAST 110 1232 2440 3934 6250 8589 10000 10000 1232 2440 3934 6250 10000 10000 10000 1-b' PRECAST 56Z 1001 1918 2942 4346 6461 10000 10000 1001 1918 2942 4346 6461 10000 10000 1'-8' PRECAST 544 915 1049 2819 4131 6010 9245 10000 915 049 2819 4131 6010 9245 10000 e'-0' PRECASt 511 916 1124 2602 3151 5030 1958 10000 916 1124 2602 3151 5405 1958 10000 B'-4' PRECAST 482 B64 1615 2415 3444 4866 &983 10000 864 1615 3444 4810 6983 10000 9'-4' PRECAST 411 141 1361 1. — 1391 2168 3169 5124 1061 141 1361 1991 2168 3169 5124 1061 10'-6' PRECAST 3413 636 1148 1649 2231 2962 3883 5094 636 1148 1649 1231 1962 3883 5094 4566 PRECAST 315 514 1028 1465 1964 2566 3305 4239 514 1028 1465 1964 2366 3305 4239 12'-0' PRECAST 792 533 950 1343 1189 2316 2951 3134 533 950 1343 1189 2316 2951 3134 13ti PRECAST 211 505 898 1264 1616 2151 2130 3426 505 Bee 1264 1616 2151 2130 3426 1370 PRECAST 455 464 822 1151 1515 1935 2425 1 3010 464 822 1151 1515 1935 2425 1 3010 1209 PRECAST 739 436 169 1013 1406 1186 2225 1 2141 436 169 1013 1406 1186 2225 2141 14'-15' PRESTRESSED N.R. N.R N.R. N.R. N.R KR KR NR 480 811 1234 1421 1119 2188 2662 15'-a' PRESTRESSED NR KR N.R 4151 KR N.R. NR. KR 454 165 1160 1331 1660 2032 2459 11'-4' PRBbtF 88ED N.R KR N.R PLR N.R_ NLR KR N.R. 389 652 982 1 1111 1319 1611 1991 19'-4' PfiESTRE88ED NR KR N.R. N.R. K N.R NR N.R 339 561 849 960 1111 1415 1616 20'-0 PRESTRE88ED N R KRL N.R. PLR N.R N.R N.R. KR 325 543 512 911 1122 1345 1590 21'-4' PRESTRESSED N.R. KR N.R. 1111 N.R. K 102N.R 295 500 146 840 1024 1224 1441 22'-0' PRE87Rf=88ED NR KR N.R. N.R. K N.R KR N.R. 261 481 111 806 981 1111 1316 24'-0' PRESTRESSED NR 7194 N.R NR KR N_R N R KR 3 6 0 3 69 N.R ■ NOt 1" COMSrlOSO 12" LINTEL UPLIFT N,Q .Not Reaaeelwd.d 8" LATERAL TABLE LINTEL SAF=E LATE=RAL LOADS (PLF) Len9�' Type SAFE GRAVITY LOADS PLF 2'•10" TO 5'-8" st Total12' L-sth TW@ 3'-6' 12/6-8-0L 12/2 -6 -OL L7/16 -8-0L 0/20 -6 -OL 044 -6 -OL I 12/18 -6 -OL 12/32 -5 -OL PIa1n t2/6 -6 -IL 12/2.6-1L 12/26-6-L 12410-6-1L 12/14.6-iL 12/16 -6 -IL 12/32 -6 -IL 2'-10' Recast 4.6' 9524 10000 1 0 loom 10000 12kZ10O vxw 1420 wvw O0__ 10000 3'-6' Precast 6'-6' 554 540 loom 10000 10000 121000 690 3204 623 10000 r7000 10000 irmy raa60 10000 W-0-SIMPreset 650 2247 4394 10000 9565 10000 I 10000 100 UNWO 102100 10000 46604'-6' 6908 Precast 3m 6 03 09 1904 10000 121Lpp fiacaet n22 3421 961 550 4-6' Precast 2% 7 'KBO _ 66 6535 10000 10!000 Retest 1696 I I 450 5'-4' Precast 10 we 14-8' Restressed n0 390 15'-4' Prestressed U39 310 3 6smam 145 10000_ Is' -41 10000 91.10' P1 at 1044 2206 4425 0051 wM00 pm ___j22w_ 235 6'-6' Precast 4176 2m Pm 0415 1025 04,33 NR ■ Na Ram mmencled 614 b6iSms 6226 6000 10000 105100 10000 1'-6' Precast 4446 5211 8Z1 4651 1260 992 19 6000 692 1bI4 26RI 401 12MO 6965 l'-8' Precast 519 119 4463 6891 9262 10000 610 1"1& 119 4463 6891 10000 10000 10000 8'-O' Precast l— 14M 636 4119 06 e 10000 679 1316 253il, 4115 6266 9363 10000 IOOOO V-4' Precast 9041 1395 2315 WS 51746 196 8141 10000 693 1299 29 146 6421 wM00 10000 9'-4' Precast tun 2011 S162 4619 OD22 Nil10000 1 606 1124 2011 A162 4619 6527 6111 10000 10'-6' Precast 466 2 4566 76" 2 5126 6W4 430 2611 3'132 506, 6W4 1 II'•4' Precast 10 V14 514 2 19 321EI 4439 Wilk - 1301 366 0 154 2315 5210 44311 "16 1611 12'-0' Precast -64 841 13ti 2121 2X4-- 4W S241 645V 360 --- 2121 4001 15,241 IFIN 12'-6' Recast 1143 603 1370 20M 1 4174 132 4664 00 341 160 6221 13'-4' Precast N66 124 1209 2 2671 3341 4313 647 814 98 2 7521 3348 43 4 14'-0' Precast 610 1131 K 346 091 3961 4604 795 L56 31 99 7346 309 961 4916 44-8' Retest 126 on 1063 bee 7161 869 3587 4151 2n eb 466 W-4' Precast Imb 442 1001 94 048 6 3246 110 262 494 1 94 2048 26 961 E4=14 4716 ll' -4' Precast 23 62 02 2419, 1141 716 316 2 IS 64 I N,Q .Not Reaaeelwd.d 8" LATERAL TABLE LINTEL REINFORCEMENT SCHEDULE ................. LENGTH LINTEL SAF=E LATE=RAL LOADS (PLF) Len9�' Type PLA FILLED 2'•10" TO 5'-8" st NONE 5'-10' To 8'4' 3'-6' Recast 1300 2550 W-0' Precast 1010 2100 4'-6' Recast 900 1150 4.6' Recast 850 1600 5'-4' Recast 110 1400 5'-10' Recast 625 1200 6'-6' Recast 540 1050 1'-6' Precast 440 690 1' 8' Precast 430 650 precast 410 820 8'.4' Reeaet 390 180 46604'-6' 6908 Reset 3m 6w 10000 Recast 550 600 2+131 fiacaet 215 550 5621 precast 2% 510 N4' Reset 245 490 13'-4' Retest 220 450 14'-0' Recast 10 we 14-8' Restressed n0 390 15'-4' Prestressed 165 310 Il' -4' prestressed 145 320 Is' -41 Prestressed 130 280 4 Prestressed 120 250 211-41 eutreebed 1671 235 22'-0' Prestressed 4176 1166 24'-0' Prestressed IM 200 NR ■ Na Ram mmencled 144 LINTEL REINFORCEMENT SCHEDULE ................. LENGTH ......+•::RMFOR ENT:....::........LINTEL 9INCH:•:::::iii::'r':::::121NCH:•:::'tit: KNOCKOUT BLOCK :_,"A"REINFORCEMENT::'::?::ii;v: i"8'REMFORCEMENT::::: 2-10" To 54' 2'•10" TO 5'-8" (2)#3 NONE 5'-10' To 8'4' 5'-10" To 6-8, 2 #4 NONE 7'-6' To 8'4' 7'-8" To 8'-4' (2 45 NONE 9-4' To 14'-0' 9'-4' To 17'4' (2)#5 #3 To 15'-4' 12/28-6-2U 2 7118' PRESTRESSED 2 #3 174' Recast 2 MT PRESTRESSED 2 #4 4To 22-0' 19'4"' 10000 1118' PRESTRESSED 2 #5 REFER TO LINTEL SECTION FOR RtINFUNULWN I LUAL;I IVrle WEKIWA LINTEL SCHEDULEI �°L 3 (1)155 CONTINUOUS TotalV KNOCKOUT BLOCK ' 4 mmb'Xlb' CcNC2T f'LACEDL IN FIELD) 3'-e' �1 590 T0� 14'-0Lt1s 12/12-5-N 12/Ib-S-IU 12/20 -6 -Ill (OPTIOONALTIPlUOUS AT 4'-0' 12/28 -6 -IU 1/32' STIRRUP'S cc tat 'A' BARB !MAIN REINFJ 12/8-641.1 SEE: SCHEDULE 7$, TYPICAL COMPOSITE LINTEL SECTION NR " Not Reap N wded 8 RECESS DOOR HEADER " I ATFRAI TARI F RECESS DOOR HEADER LINTEL TotalV Two wo SAFE UPLIFT LOADS PLF W FECE88ED FILLED 3'-e' Total 590 I2/9 -6-L 12/12-5-N 12/Ib-S-IU 12/20 -6 -Ill 12/34 -6 -IU 12/28 -6 -IU 12/37 -8 -IU tat Type 12/8-641.1 12/12-6-2U 12/16-6-7U 12/20-6-2U 12/24-6-2U 12/28-6-2U 12/32-6-2U 2'-10' Precast Recast I 950 V.S. 10000 250 160 3'-6' Precast 41My 640 9'-8' 160 490 10000 4'-0' Precast 600 6154 Precast W BARS - SEE: SCHEDULE 1 II 9 9 Precast Precast 2124 46604'-6' 6908 Precast 1pp;I 1om0® 10000 I00m0 550 1110 2+131 4216 6 843 ,6000 5621 loom loom - 4-8' Recast 9647 6076 10 13'-4' 10000 1000® 10000 14'-0' precast O we 14-8' precast 360 160 6'-4' Recast 629 15147 3 10000 lamwe 10000 0000 4 533 5117 4660 109 6166 1671 D' -IO' Precast 471 4176 1166 337 10000 10000 10000 144 1911 996 3621 4446 5211 6051 6'-6' RAsust 6 19 6615 60 6965 10000 krzoo �0 b 4 Precast 1 851 4064 5216 6492 06 e TM 1345 9kD 7416 9041 4n7 1'-6' RArGst 1562 2114 3ab 9 5 I 105 1219 1132 248 1 184 6'-O' Precast 419 466 3516 4566 561 6"8 lim 649) 1 16 6 043 10 445 D'-4' Recast 93 249 206 4161 5176 60615 1045 '� ab1 121 11 I 292 2657 15'•4' Recast WOO 1143 Mile 1 4174 b4*1 6 644 916 1197 N66 n41 Ots l0' -b' Recast 1615 1 1910 2483 3630 4203 1596 165 994 2 tr-4' From 647 126 606 I 251 3056 9547 264 466 666 6 Imb 26.1416 12'-0' Precast 7 413 1636 64 2669 311h 23 421 02 966 1141 1379 12'-6' Recast all 600 1761 1616 4 452 2840 200 351 1`13 "o N3 1134 13'.4' Recast 439 115 1111 1446 74153 126 a" U704 K' -O' Recast I 2 7194 b4 40 524 641 69 14-8' Recast 0 621 692 1161 4131 el 1 41 01 466 60b 1% 1b'-4' Recast 14 1046 12915 634 n19 253 3J 12 491 10 11'•4' Precast 231 1 4 102n4 1 W5 NR " Not Reap N wded 8 RECESS DOOR HEADER " I ATFRAI TARI F RECESS DOOR HEADER SAFE LATERAL LOADS (PLF) TotalV Two wo RECEMED PLAN W FECE88ED FILLED 3'-e' Recast 590 1115 4'-0' Precast 520 2660 4'. ' Recast 1650 2690 4'-4' Recast 1 165 1350 4-S Recast 45 1240 5'-8' Recast 320 950 V.S. Recast 250 160 T-8. ler!Mt 200 640 9'-8' Recast 160 490 12" RECESS DOOR HEADER I ATFRAI TABLE RECE55 DOOR HEADER 5AFE LATERAL LOADS (PLF) Total Logth Tt a PLAMS6FD 12' �� D 3'-6' 1 Recast 2025 3210 4'-0' 1 Recast 1710 2660 4'. ' ecast 1650 2690 4'4' Recast 1515 2940 4-6' Recast W20 2290 5'-8' Recast 1060 r150 25M Recast 815 1425 1' e' Recast 130 1190 195® Recast 550 900 1) 05 CONTINUOUS 3000 PSI CONC. FILL (CONCRETE PLACED IN PIE LD) TOP LEG BARB: 1/32'0 15AR p UP TO I '-0 LeNwHB 1/32' STIRRUPS 0 4'-0' C/C a.. (1) 05 CONTINUOUS 60 -Ki '+ (OPTIONAL) r 'A' BARS (MAIN REINFJ -IN SEE SCHEDULE SEE SCI-WDULEi 1 TYPICAL LINTEL 12"x8" SECTION 12" LATERAL TABLE • 7`zA a SAFE LATERAL LOADS (PLF) TYPICAL LINTEL 8"x8" SECTION TVP- OPTIONAL 05T Fim TOP LEG BARB: Precast 3/84 {{�LAIN 19gEiACH 6900 LECs Up' TO 14'-0' LENGTHS Precast 1/32' STIRRUPS a 4'-0' C/C 4115 4'.0' Precast 1950 3680 4'-b' Precast 1650 . '.s:1il...:7' 4-B' IONAL 0313 '11150 tINI 5'.4' Precast 1370 25M r Precast 1160 2250 'A' BARB (MAIN R,EINF.) 1000 195® Precast 620 SEE SCHEDULE NS4 Precast 600 Precast W BARS - SEE: SCHEDULE 1 II 9 9 Precast 170 11 1 TYPICAL LINTEL 12"x8" SECTION 12" LATERAL TABLE 19g1) 05 COOggNTINUODUC6 lGONGRETECP�LACED IN FIELD) 1 + TOP LEG BAFz5, 4 -4 LECs UP TO 14'-m LENGTHS (1) s5 CONTINUOUS -1cAILI !OPTIONAL) A BS�Et�AIgf�NFJ SEE a 1/32' STIRRUPS AT 4'-0' cc 7$A f TYPICAL LINTEL 8"x8" RECESSED SECTION A R C H ITEC TS 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup-com AA #: 0003325 SunDIV. 8c LOT: TUSCA SOUTH LOT X41 PROJECT# 1'703.00 MODEL: '1542" GARAGE SWING: RIGHT PAGE: LINTEL SCHEDULE (WEKIWA) (ARC HITECT) STATE OF FLORIDA DSC 9p 2009 JAMES CANTWELL A NO 12079 T`I'fi DESIC�N,4tION A=: 12/23/09 NOMINAL WIDTI-I/1-IEIS OF LINTEL PLAIN OR SOLID LINTEL SCALP: 1/4 '_1sT -0" F F SHEET LNo. OF ADDITIONAL 05 BARS IN UPPER 113. lF OR LOWER LINT(=L CAVIT7 "��-//" LINTEL SAFE LATERAL LOADS (PLF) C41 TVP- PAX% Fim 2'-10' Precast 00 6900 3'.6' Precast 2466 4115 4'.0' Precast 1950 3680 4'-b' Precast 1650 3450 4-B' Recast 850 3200 5'.4' Precast 1370 25M Precast 1160 2250 Precast 1000 195® Precast 620 1650 NS4 Precast 600 Precast 1530 Precast 170 1450 Precast 640 1110 Recast 550 1110 11'-4' Precast 510 1000 12'-0' Precast 460 990 IT -6' Precast 460 10 13'-4' Precast 430 860 14'-0' precast 400 we 14-8' precast 360 160 Fi'-4' Precast 350 130 _4' Precast 320 630 NR • Not Reeommarded 19g1) 05 COOggNTINUODUC6 lGONGRETECP�LACED IN FIELD) 1 + TOP LEG BAFz5, 4 -4 LECs UP TO 14'-m LENGTHS (1) s5 CONTINUOUS -1cAILI !OPTIONAL) A BS�Et�AIgf�NFJ SEE a 1/32' STIRRUPS AT 4'-0' cc 7$A f TYPICAL LINTEL 8"x8" RECESSED SECTION A R C H ITEC TS 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup-com AA #: 0003325 SunDIV. 8c LOT: TUSCA SOUTH LOT X41 PROJECT# 1'703.00 MODEL: '1542" GARAGE SWING: RIGHT PAGE: LINTEL SCHEDULE (WEKIWA) (ARC HITECT) STATE OF FLORIDA DSC 9p 2009 JAMES CANTWELL A NO 12079 T`I'fi DESIC�N,4tION A=: 12/23/09 NOMINAL WIDTI-I/1-IEIS OF LINTEL PLAIN OR SOLID LINTEL SCALP: 1/4 '_1sT -0" F F SHEET LNo. OF ADDITIONAL 05 BARS IN UPPER 113. lF OR LOWER LINT(=L CAVIT7 "��-//" A R C H ITEC T S I Desi n I 0(/Grou �nc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup,.com AA #: 0003325 SuBDIV. & LOT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 MODEL: "1542" GARAGE SWING: RIGHT PAGE: LINTEL SCHEDULE (PRO—CRETE) ARCHITECT - STATE OF FLORIDA 4RNO JANTWELL 12079 No DATE: 12/23/09 SCALE: 1/4"=1$-0" SHEET 1B. 2or �� k O O SQUARE FOOTAGE WINDOW SIZE AND TYPE EGRESS EGRESS OWNERS SUITE LIVING ROOM/ DINING ROOM/ OPT. BEDRROOM #4 35 -SH W/ ARCH TOP O O9 . PATIO O 5(068 S.G.D. FAMILY ROOM HEN 25 -SH EGRESS BDRM. 3 i O do snRM•#2 COMPONENT AND CLADDING WIND LOADS BASIC WIND EXPOSURE FOR 3 SECOND GUSTS CALL # SQUARE FOOTAGE WINDOW SIZE AND TYPE ZONE 110 MPH WIND REMARKS 120 MPH WIND 1 26 35-5H W/ ARCH TOP 4 20.5/ -22 3 A5-4.66= 16=0.29ft2 24.4/ -26.6 2 20 3068 DR 4 20.8/-22.6 Op 24.1/ -26.9 3 12 1H5 -8H 5 21.6/ -28.7 251/ -34.2 4 112 16'-0 X 1'-0 GARAGE DR. 5 183/ -22.4 p=-24.0(0.71)+-26.55(0.29) 21.8/ -26.7 5 1� 25 -SN EGRESS 4 21.1 / -22.9 GARAGE 25.1/ -2'1.3 6 I 25 -SH EGRESS 4 21.1 / -22.9 25.1/ -2-1.3 -1 34 5068 SJG.D. 4 202 / -22.0 24.0/ -26.2 8 1� 25 -SH EGRESS 4 21.1 / -22.9 25.1/ -2-1.3 9 1-1 25 -SH EGRESS 5 21.1 / -28.0 25.0/ -33.1 WHEN CALCULATING WIND PRESSURES ON A GARAGE DOOR, FLORIDA 5UILDING CODE, 2004 ALLOWS THE PRESSURES TO 5E AVERAGED WHEN THE OPENING 15 PARTIALLY LOCATED IN 50TH ZONE 4 AND ZONE 5 WIND PRESSURES ARE BASED ON WIND SPEED=120MPH (3 SECOND GUST) IMPORTANCE FACTOR= 1.0 EXPOSURE CATEGORY = 5 MEAN ROOF HEIGHT=LESS THAN 30 FT. FOR AN ENCLOSED BUILDING 2'-4" v 11'-4" 2'-4" ZONE 5 p = +21.8 / -26.55 ZONE 4 p = +21.8 / -24.0 LAUN. r - -1 L J PERCENTAGE OF AREA WITHIN ZONE 4: - - BRKFST �--i A4 11.33= 16=0.71 fie \� PERCENTAGE OF AREA WITHIN ZONE 5: A5-4.66= 16=0.29ft2 o � � AVERAGE POSITIVE PRESSURE ON GARAGE DOOR: Op = 21.8 (09) + 21.8 (0.10) = 19.62+2.18 ----- r , = 21.8 psf I I AVERAGE NEGATIVE PRESSURE ON GARAGE DOOR: L - - - - - J p=-24.0(0.71)+-26.55(0.29) = -17.05 + (-7.7) J = -24.75 psf. GARAGE AVERAGE GARAGE DOOR PRESSURE: p=21.8/-24.8 EL]EVATION "A" & "B" 8'-8' BEARING HEIGHT THROUGH OUT ELEVATION "A' 4 '5" 1115101I�0 01 -------------------- 16' O 35 -SH W/ ARCH TOP O --- - - - - - - - - - n ]E L1E VAT I O N BRKFST 8' - W CLG. 9'-4' E3EARING HEIGHT THROUGH OUT ELEVATION "C" 4 "D" A R C H T E C T S Design Group Inc. -1 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-7744078 www.abdesigngroup.com AA #: 0003325 SLTHDIV. & IAT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 MODEL: "1542" GARAGE SVMTG: RIGHT PAGE: WIND- LOAD CALCULATIONS CARCHITECT STATE OF FLORIDA 3 2000 DATE: 12/23/09 SCALE: 1/4"=1'-0" SHEET I C or 1 � ,.4 a 1 a a a Qa" OWNER'S DOOR BEYOND Y 4" PER ELECLGODE 1. 411 _ SQ. FT. CALC.'S I _I M m ,3 -1/2 21 � I DBL. fT m 4'-4" PATIO 1'-0"x5'-0" I 2a" OVER 0 —_----- HANG -8 SGO a) I Ul 25 -SH 25 -SH 25 -SH EGRE55 EGRE55 5068 S.G.D. HB. EGRE55 10, -- -- ■ JL OWNERS BDRM. 3 SUITE a' -a" CLG. V -S" CLG. = FAMILY e ROOM 8'-8' CLG. -1 - Y 0Y 31-0" 5' 3 38 3-0 m" 1 S31 ,2" v v 8'-0" 4-0 r- N BF. I `t' BATH #2 JtLLAV. _ � 8 NC.ACG. CRR ■ ;n 0 O" AV. o BATH a - S CLG. / s 3'-6' 3'-10" m I /// a m ``� A 3'-10.1 8f-8° iR--ISNILI \� -'IV 0 o �I -8" 4'-m" I KITCHEN z N (eNICHh (DBA R DETAIL � I 11 U) 8 SIS G.0bj 4" 51.41 , 8'-s' CLCD. � � ' 0 8D8 G'L� L _I I ' L wcI — — — — u -�- — _tu I `� o a r 4-0 BF jQ I 3 I e LAUNY' `- +� , n ■ �''8 cLCB.-c.l ��'-------- N LIVING ROOM/ I o I IR -16H DINING ROOM/ — — r___1 Iw_ OPT. BEDRROOM #4 M.T. 8 SKcsG ,�,� 1 , I s'-8" CLCD. 4'-m 8 �, I p Q l �, z l �� l 36'x48' A/c PLATFORM 4'-0" 6'-8" g 30' AFF a1_OY r — 22'x54" 1 35 -SH W/ I I —/ ACCESS I PIPE EEL ARCH TOP BOLLARD 0 GARAGE 81-511 C G. N ■ Ll -I 8'-2" 3'-10" 4'-811 3'-10" 10 1 — — 12'-0" 91-411 16'-011 1'-4" 21'-411 40'-0" iiiiiiii1j09-1 W4 -OW B.F. 8'-4" 3'-4" 18" PLANT SH. ,s 88" AFF. BDRM. V-&" cLG. I 35 -SH W/ ARCH TOP EGRESS 8'-2" 3'-1011 12'-011 COPT. ]�]EDDOOM # 4 i 10'-0" I 6n JI_On 6n 11 '----(oxro POST—" COV. PORCH 10'-0'x8'-0" i 5068 S D. I 171 L4 OPT. COV. PATIO S' -S' BEARING HEIGHT THROUGHOUT ELEVATION 'A" 4 'B" V-4' BEARING HEIGHT THROUGHOUT ELEVATION "C" 4 "D" 1 ww"g 0914H "if 1159MR11 m" . S' -S" BEARING HEIGHT THROUGHOUT ELEVATION "A" 4 "B' EXTERIOR MASONRY WALL 5RG. HEIGHTS MODEL 5PECIFICATION5 * GARAGE DRYWALL TO BE TAPED, UNPAINTED, UNFINSHED * WINDOW SILLS TO BE OPTIONAL * MASTER AND SECONDARY BATH TO RECEIVE 36' MIRROR * VANITY MIRRORS TO BE RAISED OFF BACKSPLASH * ALL DOORS ARE 6'-8" HIGH UNLESS NOTED OTHERWISE. * ALL TUB FIXTURES TO BE WALL MOUNTED ELEVATION BRKFST V-4" CLG. 9'-4' BEARING HEIGHT THROUGHOUT ELEVATION "C' 4 'D" LAV. o. ° =3 q: BATH 8'-5" GLC. LAV. 11_81 4'-4" 3'-6" 3'-10" n �e� OPT. OWNER, 9 'KI; BAT11 A R C H I T E C T S VDesign _roup inc. .441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SXMDIV. 8a LOT: TUSCA SOUTH LOT X41 PROJECT# 1703.00 MODEL: "1542" GARAGE S WING: RIGHT PAGE: FLOOR P LAN ARCHITECT- STATE OF FLORIDA I—Eck a Mg DATE: 12/23/09 SCALE: 1/4'"=1'-0" SHEET 2 OF 1 SQ. FT. CALC.'S L I V ING ENTRY ELEV. 'A' ENTRY ELEV. 'C' GARAGE 4 IIB" 4 IID' 1542 14 42 392 SQ. FT. SQ. FT. SQ. FT. SQ. FT. TOTAL ELEV. 'A' TOTAL ELEV. 'C' 4 'B' 4 'D" 1948 1576 SQ. FT. SQ. FT. PATIO OPT. COV. PATIO 35 80 SQ. FT. SQ. FT. EXTERIOR MASONRY WALL 5RG. HEIGHTS MODEL 5PECIFICATION5 * GARAGE DRYWALL TO BE TAPED, UNPAINTED, UNFINSHED * WINDOW SILLS TO BE OPTIONAL * MASTER AND SECONDARY BATH TO RECEIVE 36' MIRROR * VANITY MIRRORS TO BE RAISED OFF BACKSPLASH * ALL DOORS ARE 6'-8" HIGH UNLESS NOTED OTHERWISE. * ALL TUB FIXTURES TO BE WALL MOUNTED ELEVATION BRKFST V-4" CLG. 9'-4' BEARING HEIGHT THROUGHOUT ELEVATION "C' 4 'D" LAV. o. ° =3 q: BATH 8'-5" GLC. LAV. 11_81 4'-4" 3'-6" 3'-10" n �e� OPT. OWNER, 9 'KI; BAT11 A R C H I T E C T S VDesign _roup inc. .441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SXMDIV. 8a LOT: TUSCA SOUTH LOT X41 PROJECT# 1703.00 MODEL: "1542" GARAGE S WING: RIGHT PAGE: FLOOR P LAN ARCHITECT- STATE OF FLORIDA I—Eck a Mg DATE: 12/23/09 SCALE: 1/4'"=1'-0" SHEET 2 OF 1 (o' SGORI 8' -5' SRG. HGT. m' -m" FIN. FLR. — v vvv���r r�� �r • � � � •• P-RONT ELEVATION TEXTURED FINISH >i r I �OFF RIDGE VENT OFF RIDGE VENT 1 �, ll' -l' BUILD INC- HGT. OIL S'-8' 5R.G. NGT. 6" SCORED BAND (TYP.) OL m'-0' FIN. FL R. 6-5' BRG. WGT. REAR ELEVATION TEXTURED FINISH 6' SCORED BAND KEYSTONE -r-- r -dl F s7g = '-o DETAIL COPT. COV. PORCH A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 StMDIV. & LOT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 MODEL: 1542" GARAGE SWING: RIGHT PAGE: ELEVATION ,) A„ FRONT & REAR ARCHITECT: STATE OF FLORIDA Dn VA 2M JAM DAJE: 12/23/09 SCALE:1/4"=l 1-09) SIMET 3 A of 4 V-8" SRG. NGT. 0'-0" FIN. FLR ®]PT. COV. PORCH RIGHT SIM. 0'-0" FIN. FIL OFF RIDGE VENT II_0N cs� " RIGHT ELEVATION -- TEXTURED FINISH ly I _ 0 N 2'-4" 0'-0" FIN. FLR 1 12 1 OFF RIDGE VENT L'i F 1L TEXTURED FINISH ET EVASION S' -S' BRG. HGt. 0'-0" FIN. FLR. I_AN 0' -O" -FIN. FLR If f A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-7744078 www.abdesigngroup.com AA #: 0003325 SUDDIV. & LOT: TUSCA SOUTH LOT X41 PROJECT# 1703.00 MODEL: 1542" GARAGE S WING: RIGHT PAGE: ]ELEVATION A" LEFT & RIGHT ARCHITECT: STATE OF FLORIDA Dr c� i:'3 C 2!�U� DATE: 12/23/09 SCALE: 1/4""=1"-0"" SHEET �— A OP'01 1— HEADER SPAN CHART CONNECTOR SCHEDULE 5'-0" TO SIMPSON STORY APPLICATION DES. UPLIFT GRAVITY FASTNER >- META -16 1450 (1) I0d x 1 1/2 I -PLY/ (6) 16d2 -PLY Z 0 (2) META -16 1985 (10) 10d x 11/2 I -PLY 1900 (14) 16d 2 -PLY 0 HETA-16 1810 (9) I0d x 1 1/2 I -PLY/ (8) 16d 2 -PLY a � HETA-20 1810 (9) Imd x 1 1/2 I -I -LY/ (8) Ibd 2 -PLY TWO STORY APPLICATION DOWN STAIRS (2) HETA-20 2035 (10) I0d x 1 1/2 I -PLY 2500 (12) 166 2 -PLY NUMBER OF FULL LENGTH STUDS MGT + 3965 (1) 5/8' A.T.R IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (22) 10d TO WOOD SIZE HGT-2 + 10980 (2) 3/4' AT.R. N HIGH STRENGTH EPDXY (MIN. 12' EMBED), (16) 10d TO WOOD CLEAR SPAN HGT-3 + 10530 (2) 3/4' A.T.R. N HIGH STRENGTH EPDXY (MIN. 12' EMBED), (16) 10d TO WOOD x 6 x 8 x 10 x 12 LTA) 1420 (12) Imd x 1-1/2' VGT 4940 (1) 5/8' ATR IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (I6) SDS 1/4' X 3' TO WOOD (2)YG1(2-PLya-PLY) 1185/8890 1 (2) 5/8' A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (32) 8D8 1/4' X 3' TO WOOD MTS -12 1000 (14) Imd x 1 I/2 HTS -16 1150 (16) loci x 1 1/2 HT8-20 1450 (24) 10d x 1 1/2 LSTA-12 ++ 925 (10) 106 LSTA-18 ++ 1235 (14) Imd V) MSTA-18 ++ 1315 (14) 106 In- MSTA-24 +a 1640 (18) I0d Cr M5TA-36 ++ 2050 (26) I0d ~ V) MSTI-36 3800 (36) Imd x 1 1/2 MStI-48 5065 (48) I0d x 1 1/2 H6 950 (8) ed t0 PLATES, (8) 8d To STUDS 5P4 885 (6) 10d x 1 1/2' TO STUDS A33 '150 (4) Imd TO BEAM (4) 10d TO POST. HCP2 645 (6) 10d x 1-1/2' HIO 995 (16) Bd x 1-1/2 ABU 44 2200 6665 (1) 5/8' A.T.R. IN HIGW STRENGTH EPDXY (MIN.1' EMBED_) IN CONC. (12) ibd TO WOOD (n ABU 66 2300 12000 (1) 5/8' A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 1' EMBED.) IN CONC, (12)lbd TO WOOD LTT19 +++ 1340 (1) 3/4' A.TK N HIGH STRE1JGt14 EPDXY (MIN. 1' EMBED.) N CONC, (8JI0d to WOOD UI-TT2015+++ 1625 (1) 1/2' AT IN HIGH STRENGTH XY (MN. I' EMBED.) IN CONG (2) A' DOLT TO WOO 2 U Z HTT-16 +++ 3955 (1) 5/8' AT.R. IN HIGH STRENGTH EPDXY, (MIN. V EMBED-) IN CONC, (18)lbd X 2 1/2 t0 WOOD Q NTT -22 +++ 4165 (1) 5/8' A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 1' EMB£DJ IN CONC, (32)16d TO WOOD HHpQII-SDS 25+ 11,445 (1) V Au.T�R N HIGH STRENGTH EPDXY, (MIN. 10' EMBED.J N CONC, (24)5D5 4' x M, WOOD SCRE HDI 6480 (1) 1/8' AB. IN HIGH STRENGTH EPDXY (MIN. 1' EMBEDJ IN GONG (3)V STUD BOLTS TO WOOD MBNA 356/11.25 3415 5330 (1) 3/4' A.TR IN HIGH STRENGTH EPDXY, (MIN. 6.15' EMBEDMENT) IN C.M.U. TOP, (1) 3/4' A.TR IN HIGH 67RENGTH EPDXY, (MN. 615' EMBEDMENT) IN CM!_!. FACE, ObA0d TO BEAM V) Q:: HUSC412 (WOOD) 3240 2510 (FLO (I0) Ibd TO HEADER, (10) 16d TO WOOD 3140 (ROOF) W 0 HUC41m (CMU) 1810 5085 18-1/4' x 2-3/4' TITEN (9 PER FLANGE) TO CMU (10) Imd TO WOOD Z Q HIGH STRENGTH EPDXY ■ 61MPSON 'SET EPDXY-TIE'. CONTACT THE ARCHITECT/ENGNEER OF RECORD FOR WRITTEN APPROVAL PRIOR TO SUBSTITUTING FOR SIMILAR EPDXY PRODUCTS. + WHERE ANCHOR EMBEDMENT 18 GREATER THAN 1' DEEP, THE VERTICAL CELL IN C.M.U. WALL MUST BE FILLED SOLID w/ GROUT. ++ 10d COMMON NAILS CAN BE SUBSTITUTED WITH 10d x 1 1/2' NAILS IN CONJUNCTION WITH A 23% REDUCTION IN THE ALLOWABLE LOAD. WRITTEN APPROVAL FROM THE ARCHITECT IB REQUIRED FOR THIS APPLICATION PRIOR TO INSTALLATION. V) W +++ MINIMUM EMBEDMENT INTO THE TOP OF A 15ON05EAM WILL BE 5', MINIMUM EMBEDMENT INTO THE FOUNDATION WILL BE V 0 A.T.R. - A-301 ALL THREAD ROE) (SIZE, PROTECTION TYPE, LENGTH, ETC. VARIES) Z BECAUSE OF THE WIDE VARIETY OF MATERIALS, LOCATIONS, AND CONDITIONS THAT MAY AFFECT CONNECTORS, THE CONTRACTOR MUST BE RESPONSIBLE FOR MAKING SURE THAT THE PROPER CORROSION PROTECTION 18 USED. WHEN USING STAINLESS STEEL CONNECTORS, USE STAINLESS STEEL FA8TENERB. WHEN USING IMAX / HDG GALVANIZED CONNECTORS, USE FASTENERS GALVANIZED PER ASTM -A153 USE OF EXPANSION ANCHORS WILL BE EVALUATED ON AN INDIVIDUAL BASIS AND MUST HAVE WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER OF RECORD PRIOR TO USE. ALL CONNECTOR VALUES BASED ON SIMPSON 'WOOD CONSTRUCTION CONNECTORS C-2009' 'NIGH WND-RESISTANT CONSTRUCTION C-HW05-R', t-ANCHORSPEC01, AND ANCHORING t FASTENING SYSTEMS FOR CONCRETE t MASONRY CATALOG C-2009. HEADER SPAN CHART MINIMUM WALL AND HEADER STUD REQUIREMENTS MAXIMUM HEADER SPAN (ft.) UP TO 5'-0" TO SINGLE STORY APPLICATION 4'-11 1/2' -l'-11 1/2' AND UP SIZE CLEAR SPAN D5L 2 DBL 2 DSL 2 D5L 2 x 6 x 8 x 10 x 12 UP TO 5'-4' 5'-4' TO 'V-0' 1'-0' TO 10"-0' 10'-0' AND OVER TWO STORY APPLICATION DOWN STAIRS 3 NUMBER OF FULL LENGTH STUDS SIZE CLEAR SPAN D5L 2 D5L 2 D5L 2 DSL 2 x 6 x 8 x 10 x 12 UP TO 5'-0' 5'-0' TO 6'-4' 6'-4' TO 8'-O' 8'-0" AND OVER MINIMUM WALL AND HEADER STUD REQUIREMENTS MAXIMUM HEADER SPAN (ft.) UP TO 5'-0" TO 8'-0' UN.O. 4'-11 1/2' -l'-11 1/2' AND UP NUMBER OF HEADER STUDS SUPPORTING END OF HEADER 1 2 3 NUMBER OF FULL LENGTH STUDS 2 AT EACH END OF HEADER 1 3 2 x 12 (#2 SYP) I/16" OSB NAIL (3) 126 6 6'-8" O.G. TYP. 2x12 BM. f HDR. FRAMING NOTES: 1. HURRICANE STRAPS TO 5E MANUFACTURED 5y SIMPSON STRONG -TIE OR ECUAL, U.N.O. 2. TYPICAL HURRICANE STRAPS ARE AS FOLLOWS, U.N.O: * TRUSS TO MASONRY/CONCRETE SHALL 5E META -16 * FLOOR JOIST TO MASONRY/CONCRETE SHALL 5E HETA-1( AT EACH END AND 32" ON CENTER ON JOISTS PARALLEL TO WALL. * TRUSS TO WOOL) FRAMING SHALL 5E MTS -12 3 -TRUSS TO TRUSS CONNECTIONS AND HANGERS SHALL 5E DESIGNED AND SUPPLIED 5Y TRUSS MANUFACTURER. 4. REFER TO TRUSS MANUFACTURER'S SIGNED AND SEALED DRAWINGS FOR LOCATIONS, PROFILE, AND SIZE OF ROOF/FLOOR TRUSSES. S. HEADER SPAN CHART 4 MINIMUM WALL 4 HEADER STUD REC. ARE STANDARD U.N.O ON FRAMING PLAN (o. MIN. 2X4 HIP CUT BLOCKING SECURED W13-106 GUN NAILS OR 3-126 HAND DRIVES e EA. END. CUT PITCH 4 5EVEL TO FIT TIGHT TO TRUSS AS PER APA RECUIREMENTS. I 2X10 BM TO 6X6 POST 1 (2) M5TA-24 POST TO SLAB ABU -66 C�E3 _2x70 5M I T3 ca I In = I m 0 1=t o 1 0 . I N I pr I I— —I „ I T3 I I VS HUG410 ��� V4 yv�'� HUC410 3/f6 W/8 -'X211 _A� UJ18-346'X2" TAPCONS (4 TAPCON5 (4 PER FLANGE) PER FLANGE) / COV P 0 C H 1 28" OVER HANG 61 SGD J1 - II■ II _ _II _ I J1 �, II 1I�fC—j I II II II II II � II II � )I ) ) � J3 ]II J3 _ l II II II II =J5 (2) META -16 (2) META -16 _ HS _ =H11 H15 N55 I I I I c H4 T2A T2A Q _ _ TIALu_ T2A 0�� SII II SII �II� _ _ = 2X12 13M. - - _ — — T1A T2 — GE2 HUC-410 — 22'x54" UJ/ 8-3/16' x 2' P1ACATTIC I T1 TACONS — J — _ (4 PER EA. — — FLANGE) Tl (Y T1 HSA HIA J5 II II II II �5 J3 J3 JI II csl II r r r J^ TRUSS v _,,-,�AMING PLAI J1 C✓/ SOUTHERN TRUSS 03/26/05 A R C H 1T E C T S DesPine. n Grou 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-7744078 www.abdesigngroup.com AA #: 0003325 S'UBDIV. & LOT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 MODEL: "1542" GARAGE SWING: RIGHT PAGE: FRAMING. PLAN ELEVATION ARCHITECT - STATE OF FLORIDA Di.V r(� 2 DATE: 12/23/09 SCALE: 1/4"=1'-0" SHEET (b 125V OUTLET 20 AMP IIOV OUTLET 1/2 OF OUTLET PHASE, 3W LOAD INFORMATION 110V OUTLET WIRED to 120/1 CB SWITCH WIRE 11500 VA EQUIPED WITH GROUND FAULT 110V OUTLET INT RUPT 515TANT 1 GFI (TA REFRIGERATOR III WIRE 20/1 ® 220V OUTLET CONNECTION WP EXTERIOR GROUND FAULT GFI WATERPROOF INTERRUPTER 20/1 OUTLET 12 SWITCH DISPOSAL SWITCH 3 -WAY OPER u/4 SWITCH 4 -WAY OPER n WALL 500 MOUNTED 1v LIGHT 20/1 CEILING LIGHT 1 VAPOR `OwP ooF � HT r 1 RECESSED l0� CAN 1 CFM F 60/2 VENT, FAN SQ. FT. 6 VENT. FAN 1 CFM PER WATER HEATER W/LIGHT SQ. FT. 2' LIGHT STRIP 10:12 4' LIGHT STRIP 4500 SMALL APPLIANCES CIRCUITS 4' RECESSED 2-5UL5 WRAP ® FLUORESCENT LIGHT AROUND 12 2' FLuolREscENT 1538 5Q. FT. LIGHTNING/ RECEPT 6 4' FLUORESCENT 4' TRACK LIGHT ® PANEL 14614 METER SMOKE BATT. BACK-UP O$,p, DUIRE DETECTOR w/ INA 6 ®ACK-UP A/C CONDENSER MOUNTED W/ HARDWIRE SD. TOR 24:26 CONNECTED NDEEEC 4060 BATT. BACK-UP TOTAL CARBON W/ HARDWIRE ®S/CO MONOXIDE/INTER- CONNECTED SERVICE LOAD SUMMARY SMOKE DETECTOR SHALL 13E A DEMAND COMBO DISTANCE OF NOT vA LE66 Alc LOAD LESS THEN 4' FROM WALL 35,07- 10000 10,00 rc 4,060 5,525 PENDANT REMAINDER FffR NEG -220-30 (B) LIGHT PUMP SUPPLEMENTAL EI -EG HEAT 6 io .HEAT vTELEPHONE JACK L 1 1 WATER HEAT. u DISCONNECT AIR GOND. A/C DISCONNECT TELEVISION TV. JACK CEILING BOX REQUIRED TO SE SUPPORTED J O J -BOX IN ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECT ION CEILING CEILING X FREQUIRED TO AN/LIGHT BE SUPPORTED IN ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION FLOOD LIGHT OPTIONAL KP ❑ SECURITY KEYPAD • PUSH- FOR BUTTON CHIMES •• NOTES: - LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO BE VERIFIED s HOMEOWNER PRE -CONSTRUCTION MEETING. ALL RECEPTACLES IN ALL HABITABLE ROOMS TO BE ARC FAULT PROTECTED PER NEC 210.12(b) • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GFI -0 ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXAUST FAN TO HAVE MIN. CAPACITY OF 50 CFM INTERMITTENT.(FBC 200'1,RESIDENTIAL CODE TABLE M15063) • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL ON FEEDERS • WIRING METHOD SHALL BE NON METALLIC CABLE AS N.E.G. 2008 ARTICLE 300.(5) (2) • ALL RECEPTACLES TO BE TAMPER- RESISTANT TYPE f �I OWNERS SUITE CEILING MTD. \ LIGHT TO BE INSTALLED, PROVIDE J -BOX FOR OPT. FAN 0. BATH PATIO GFI WP� � CEILING MTD. LIGHT TO BE FAMILY INSTALLED, ROOM PROVIDE J -BOX FOR OPT. FAN �I I� S/Co II' ��I l GFI � BDRM. 3 / CEILING MTD. LIGHT TO BE INSTALLED, PROVIDE J -SOX FOR OPT. FAN BATH �Ico I S I / J I CsFI \ 1 I I o KITCHEN W.I . C. I I GFI \ CEILING MTD. L------- U 1 LIGHT TO BE II 1 GFI I IGF( BDRM. 2 INSTALLED, 1 1 I I PROVIDE J -BOX FOYER 1 I p',i FOR OPT. FAN LIVING ROOM/1 i II j � _L DINING ROOM( I I / I I / _ _ - /� LAUN. H I ia 1L�-------- /�/►�\�\ — — -1 CEILING MTD. BRKFST I IOQ—J WH `GOND. LIGHT TO BE / �"� �I INSTALLED, - - PROVIDE J -BOX I 1 P.B. FOR PANELGF I's A/ FOR OPT. FAN CHIMES P.B. FOR 0,1 2 "A F_ \ GARAGE \ 2" STEEL PIPE METER k=LE off; I BOLLARD FIELD J - I VERIFY \� WALL MOUNTED - J I 36"X48" A/C LOC. PA LIGHT W/SWITCH IN 30tFORM AFF 1 \ ATTIC \ KEYLESS FIXTURE 1 I CLG. I OUTLET UFI I GARAGE II --------------------- -------------------- \v J j OPT CARRIAGE ------------- CARRIAGE L IGHT 4 L IGHT 4 SWITCH SWITCH lEL]ECTRICAL PLAN NOTE: ALL BRANCH CIRCUITS IN THE BEDROOMS ARE TO DE PROTECTED BY AN ARG -FAULT INTERRUPTER LISTED TO PROVIDE PROTECTION OF ENTIRE BRANCH CIRCUIT T / I 11/2 / 11/2' I 2" V.T.R.I� SHWR rl 1/2" PLUMBING RISER DIAGRAM ----------- f1 s ^ 9/GO® 100, CEILING MTD. BDRM.#4 LIGHT TO BE INSTALLED, PROVIDE J -BOX FOR OPT. FAN � OPT@ f C l D 1'. ! ; -2' 0 PANEL: UNIT 1,542 150A, MAIN LUG, 120/24OV, 1 PHASE, 3W LOAD INFORMATION 120/1 CB CKT. WIRE 11500 VA LAUNDRY/ WASHER 1 12 REFRIGERATOR 20/1 2 12 1200 DISHWASHER 20/1 3 12 1200 DISPOSAL 20/1 4 12 500 MICROWAVE/ HOOD 20/1 5 12 1500 DRYER 30/2 6:8 10 500 RANGE 60/2 -1:9 6 1200 WATER HEATER 30/2 10:12 10 4500 SMALL APPLIANCES CIRCUITS 20/1 11,13 12 300 1538 5Q. FT. LIGHTNING/ RECEPT 6 3 WATTS 20/1 14 TH U 22 12 14614 A/C AIR HANDLER 50/2 23:25 6 8500 A/C CONDENSER 40/2 24:26 10 4060 TOTAL CONNECTED VA 4-1,514 SERVICE LOAD SUMMARY DEMAND vA LE66 Alc LOAD 35,07- 10000 10,00 rc 4,060 5,525 T 10,00010051-1 -TO —.7 REMAINDER FffR NEG -220-30 (B) HEAT PUMP COMPRESSOR 100% PUMP SUPPLEMENTAL EI -EG HEAT 6 io .HEAT TOTAL LOAD VOLT 240 VA 29,59 AMPS 123 NOTE: ALL BREAKERS SERVING BEDROOM RECEPTACLES SHALL BE ARG -FAULT TYPE PER NEC 210-12 REQUIREMENTS. aI POWER COMPANY 0. \ f PEDESTAL BATH PP, FOAI i I v I SERVICE BY ( OTHERS I W.I.C. � J -\\ ]OATH®�T• OWNER'S GRADE LINE s ELEC` FRICAL i;RISER SCALE: NTS NOTE: ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER CO. (2) * 4/0 XHHW ALUMINUM CONDUCTORS (1) * 2/0 XHHW ALUMINUM NEUTRAL. (1) * 4 XHHW ALUMINUM EQUIP.GRD qsp NEMA 3R COMBO DISCONNECT 150 AMP AND 120/240 VOLT M METER CAN 42 CIRCUITS MLO INTERSYSTEM BOND ING 150 TERMINAL AT LOW AMP. VOLTAGE CONNECTIONS PHONE / DATA WEATHER PROOF BOX CABLE / TV WEATHER PROOF BOX (1) * 4 THHN/THWN COPPER SERVICE GROUND CONNECTED TO CONCRETE ENCASED FOOTER STEEL PER NEC 2008 250.52(3). 5 /8"DIA X 8FT LONG COPPER GROUND ROD A R C H IT EC TS 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SUHDIV. 8a LOT: TUSCA SOUTH -LOT X41 PROJECT# 1'703.00 MODEL: 1542" GARAGE SWING: RIGHT PAGE: ELECTRICAL PLAN ARCHrTECT: STATE OF FLORIDA Did 2/A 2013S LL DATE: 12/23/09 SCALE: 1/4"=1"-0"" SHEET r) or (1) 5 REBAR VERTICALLY W/ CONC. POUR CELL R-42 INSULATION Z TEXTURED FNISH Jw s' CMU r - I/2' GYP. WL. BD. WOOD BASE 0 US'. 4' CONC, RENF. W/ 6'xb' MO WWIM OR P15EFM O14 ON 6 -MIL POLY ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL > (2) 5 }DEBAR ON CHAIRS 1—STORY FOOTING 1 W r BLOCK WALL SCALE: 1/1'-1'-0' ifl ' 4' CONC, REINF. W/ 6'X6' _010/10 WILM OR NBERMESH ON 6 -MIL POLY ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL (1)'5 REBAR ON CHAIRS 4 THICKEN EDGE C M d ° 4' CONC, RE INF. W/ 6'x6' 010 Ulm OR FIBERMESH ON 6 -MIL POLY �4' ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL GARAGE STEP—UP rJ NON—BEARING GRADE d 4 a d . < ° •,', 4' CONC, MPF. W/ 6'x6' 010 WIIIM OR FIBERMESH ON 6 -MIL POLY ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE � s 4' S' 8' 4' TREATED FILL 2'-0" 4" 05 REBAR ON CHAIRS Z 1= @)_qONCR ETE PAD POURED LINTEL CONT. (TYP.) 8' CMU FILLED CELL (TYP. —2X WALL FRAMING ANCHOR BOLTS or ( 4) )4'X1' J -MOLTS MIN. 5' EMBEDMENT W/ 2'X2'X1/S' WASHER AND NUT SPACED EVENLY FROM FLOOR TO BOND BEAM. SET IN JOINTS PRIOR TO FILLNG. (SLEEVED ANCHOR N SOLID POUR ACCEPTABLE RETROFIT) EXT. /INT. FRAME WALL TO 15 BLOCK .WALL CONNECTION SCALE. I/2'■i'-0' (1) 05 REBAR SET IN SIMPSON HIGH STRENGTH EPDXY 1' EMBED. MIN. 1- 4' CONC, REINF. W/ 6'x6' 010 WWM OR d FIBERMESH ON 6 -MIL POLY ETHYLENE VAPOR BARRIER ON ° • °� WELL -COMPACTED CLEAN TERMITE TREATED FILL TYP. RETROFIT FOR A OMITTED DOWELS SECURE BT. PLATE TO MILK W/ ;' ANCHOR BOLT W/ 2' WASHER SET IN 81MPSON HIGH STRENGTH EPDXY 1' EMBED. MIN. a 32' OC MAX • °CRIBERMESH EINK W/ 6'x6' M0 WUM OR ON 6 -MIL POLY VAPOR BARRIER ON ACTED CLEAN TERMITE LL 4' S'AR ON CHAIRS 1—STORY FOOTING AT L.B.W. W UPLIFT STUDS 16' O.C. MAX 5 1/2' • HEAD OF GARAGE VARIES WITH SLOPE SECURE BT. PLATE TO BLAB W/ ANCHOR BOLT W/ 2' WASHER SET IN SIMPSON HIGH STRENGTH EPDXY 1' Q EMBED. MIN. a 32' OC MAX. ' 4' CONC, FVNF. W/ 6'x6' 010 WLM OR Q' P15ERMESW ON 6 -MIL POLY lil ETHYLENE VAPOR BARRIER ON > WELL -COMPACTED CLEAN TERMITE ins :4' 8' 4' 4'TREATED FILL \_ 1 -4' (2) 05 REBAR ON CHAIRS GARAGE STEP—UP 6 1—STORY L®B. W. I' RECE8 FOR " Bap. TRACK d) FINISH FLOOR ul w �j ° da 14 SLAB AT S. G. D. 10 SCALE: 1'-1'-0' CAULK AND SEAL GAS LINE PVC SLEEVE FOR GAS LINE 97- = = S' CMU �I/2' DRYWALL WOOD BASE ° 4, SECURE BT. PLATE TO SLAM W/ I' ANCHOR BOLT W/ 2' WASHER BET IN SIMPSON HIGH STRENGTH EPDXY 1' EMBED. MIN. a 32' OC MAX. f.' CONC, RENF. W/ 6'x6' MO WWM OR BER"IESH ON 6 -MIL POLY WHYLENE VAPOR BARRIER ON LL -COMPACTED CLEAN TERMITE -EATED FILL ) 05 RE15AR ON CHAIRS 2 -STORY FOOTING 5 1/2' a HEAD OF GARAGE VARIES WITH SLOPE SECURE BT. PLATE TO SLAB W/ }' ANCHOR MOLT W/ 2' WASHER SET N SIMPSON HIGH STRENGTH EPDXY 1' N EMBED. MIN. a 32' OC MAX. Q ° 4' CONC, REINF. W/ 6'x6' 010 WWM OR FIMERMESH ON 6 -MIL POLY Z ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE s 4' 6' 6' 4' 4 TREATED FILL I -B' (3) 05 REBAR ON CHAIRS GARAGE STEP-UP 6 A 2 -STORY L.B. W. SCALE: 1/2' =1'-m' v I GACRAGE DOOR Q� 44 4' CONC, RENF. W/ 6'x6' 010 WWM OR FIBERMESH ON 6 -MIL POLY 1'-0' ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL (1) 5 REBAR ON CHAIRS 11 GARAGE DOOR FOOTING SCALE: 1/2' • I'-0' SECURE BT. PLATE TO SLAM W/ 10d CUT NAILS/ MASONRY NAIL a 32' O.C. MAX e • ° 4' CONC, REIPIF. W/ 6'x6' 010 ULM OR FIMERMESH ON 6 -MIL POLY Z IV ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL 4' 8' 4' iL (2) 45 REBAR ON CHAIRS 1—STORY FOOTING B AT L.B.W. W NO—UPLIFT) SCALE= 1/2'■I'-0' EXTENDED SLAB 1 1/2' CURB HEIGHT VARIES 1/2' RECESS FOR SERVICE DR v � ° z C 4' CONC, RE NF. W/ 6'x6' 010 WLM OR ' . FIBERMESH ON &P -MIL POLY 'd ° ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL O(2) 05 REBAR ON CHAIRS 'n U SLAB AT GARAGE ►� SERVICE -DOOR �1 NOT USED TEXTURED FINISH R-11 INSULATION MIN. STUDS 16' O.C. MAX 1/2' GYP. WL. BD. Lu WOOD BASE f? SECURE BT. PLATE TO BLK W/ p� ANCHOR BOLT W/ 2' WASHER SET IN �ry SIMPSON HIGH STRENGTH EPDXY 1' m p EMBED. MR ,@ 32' OG MAX. r z ° ip Q 41 CONC, REINF. W/ 6'x6 "10 WWM OR FIBERMESH ON 6 -MIL POLY ETHYLENE VAPOR BARRIER CN WELL -COMPACTED CLEAN TERMITE Wa TREATED FILL (2) 5 REBAR ON CHAIRS 1—STORY FOOTING 3 W FRAME WALL SCALE. 1/2'-P-0' (1) 5 REBAR VERTICALLY W/ CONC, POUR CELL Z s' CMu N ip p I CURB HEIGHT VARIES i0 ° p % ', 4' CONC, REINF. W/ 6'x6' 010 WWM OR a FIBERMESH ON b -MIL POLY • ETHYLENE VAPOR BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL 14'8' 4' (2) 05 REBAR ON CHAIRS 1 -STORY FOOTING 8 AT �GARAG�E 2 -STORY FOOTING gYZ BLOCK WALL SCALE: i/2"=1'-0' TIE VERTICAL REBAR TO HORIZATIONAL REBAR W/ 8' HOOK GROUTED MOND BEAM VARIES PER ELEV. v' C 16 GAS LINE THRU BLOCK E_ ,• -0' (U 5 REBAR VERTICALLY W/ CONC, °e POUR CELL R-42 INSULATION z _ qw TEXTURED FINISH i Q w e" cmu r J 4 w 4' CONC, RENF. W/ 6'x6' 010 WWM OR < INSPE d E 1/2' GYP. WL. MD. , �p O I WOOD BASE ETHYLENE VAPOR BARRIER ON ° r�TRE WELL -COMPACTED CLEAN TERMITE FILL 1 9 4' CONC, R6INF. W/ 6x6'010 ULM OR I ° FIBERMESH ON 6 -MIL POLY 0'-0' FIN. FLR. `� ' • . a ETHYLENE VAPOR BARRIER ON Z ° WELL -COMPACTED CLEAN TERMITE TREATED FILL (3) 5 REBAR a 2 -STORY >: E ° .d (3) 05 REBAR ON CHAIRS a' a LAPPED W/ BOND BEAM io 6' PVC CHASE THRU FOOTING 2 -STORY FOOTING gYZ BLOCK WALL SCALE: i/2"=1'-0' TIE VERTICAL REBAR TO HORIZATIONAL REBAR W/ 8' HOOK GROUTED MOND BEAM VARIES PER ELEV. v' C 16 GAS LINE THRU BLOCK E_ ,• -0' 2 -STORY BAR°N�HA"� (3) 05 REBAR ON CHAIRS (1) 5 REBAR VERTICALLY W/ CONC. POUR CELL R-42 INSULATION 13' cm °e VARIES PER ELEV. 1/2' GYP. WL. 130. CURB HEIGHT VARIES _ qw TIE VERTICAL REBAR Z WOOD BASE W REFIRED '' CFOR °' :. S 4 w 4' CONC, RENF. W/ 6'x6' 010 WWM OR < INSPE d J7! FIBERMESH ON 6 -MIL POLY , ETHYLENE VAPOR BARRIER ON ° r�TRE WELL -COMPACTED CLEAN TERMITE FILL FILL TREATED 0'-0' FIN. FLR. (2) 05 REBAR a 1 -STORY Z (3) 5 REBAR a 2 -STORY (U 05 VERT. DOWEL E ° .d a °' '' ° °' TTO IE VERTICAL REBAR d a' a LAPPED W/ BOND BEAM io 6' PVC CHASE THRU FOOTING .° < HORIZATIONAL d OUTSIDE REBAR TO BE CONTINUOUS r^ ° ° fl) 05 REBAR AT CORNERS 111125' LAP MIN. • • d'; REBW/ 8' HOOK �� �� . •--•- . a' d d s q ° °°. A a E I -STORY i (2) 05 REBAR ON CHAIRS UUU in 4. 2-STORr I'-4' (3) 5 REBAR ON CHAIRS 2'-I' MIN. LAP p PIPE THROUGH CLEANOUT REQUIRED TYP. REBAR LAP 1 -STORY FOOTING HORIZONTAL/VERTICAL REBAR LAP AT FOOTING AT LINTEL CORNERSD W BLOCK WALL E REINFORCING B SCALE: Imo'■1'-0' c SCALE: I/2' -I'-0' SCALE: 1/2'-1'-0' SCALE= -0' ALL, EXTERIOR FOOTERS AT FINIS I -I SEA -B'S TO BE MIN. 12" BET O W U1%,TDIS TUFZI3ED SOIL TEXTURED FINISH R-11 INSULATION MIN. STUDS 16' OL. MAX 1/2' GYP. WL. BD. w WOOD BASE z SECURE BT. PLATE TO MLK W/ ANCHOR BOLT W/ 2' WASHER SET IN SIMPSON HIGH STRENGTH EPDXY 1' m Q EMBED. MIN. a 32' OC MAX. a °' < •q' " d 4' CONC, REINF. W/ 6'x6' 010 U•1M OR FIMERMESH ON 6 -MIL POLY ° ETHYLENE VAPOR BARRIER ON �° a • WELL -COMPACTED CLEAN TERMITE TREATED FILL r p(3)'S REBAR ON CHAIRS U4' 6' 6' 4' 1'-8' e. 2 -STORY FOOTING 3 A FW FRAME WALL SCALE: I/2"=1'-0' (3) 05 REBAR ON CHAIRS L-,"4 4' 6' 6` 4' 2 -STORY FOOTING 8 A AT GARAGE SCALE. 1/2' =1' -0' 14 NOT USED GROUTED BOND BEAM (U 5 REBAR VERTICALLY I W/ CCNC. POUR CELL s' cm VARIES PER ELEV. CURB HEIGHT VARIES _ qw TIE VERTICAL REBAR 4' CONC, REINF. W/ 6'x6' 010 WWM OR i S FIBERMESH ON b -MIL POLY q' VARIES PER ELEV. ETHYLENE VAPOR BARRIER ON P II LLA -COMPACTED CLEAN TERMITE r�TRE FILL (3) 05 REBAR ON CHAIRS L-,"4 4' 6' 6` 4' 2 -STORY FOOTING 8 A AT GARAGE SCALE. 1/2' =1' -0' 14 NOT USED HORIZONTAL/VERTICAL REINFORCING AT F BEARING CHANGE A R C H I T E C T S Irz Desin Groupinc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 sUBDIV. & LOT: TUS C A SOUTH LOT X41 PROJECT# 1703.00 MODEL: "1542" GARAGE STFMG: RIGHT PAGE: MONOLITHIC FOUNDATION DETAILS/ SECTIONS ARCHITECT: STATE OF FLORIDA DEC 2t 2009 DATE: 12/23/09 SCALE:1/4 ?f=V_Of? SHEET Di OF 16 GROUTED BOND BEAM VARIES PER ELEV. Le TIE VERTICAL REBAR TO HORIZATIONAL S 4.. REBAR W/ 8' HOOK q' VARIES PER ELEV. P GROUTED BOND BEAM 4q 1. a' d ° q 4 •e p CLEANOUT REQUIRED FOR INSPECTION d N ° FIN. FLR ° •e '. '. e ° TIE VERTICAL REBAR a d TOHORI, ATIONAL ° ° ° REBAR W/ 8' HOOK M VnY HORIZONTAL/VERTICAL REINFORCING AT F BEARING CHANGE A R C H I T E C T S Irz Desin Groupinc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 sUBDIV. & LOT: TUS C A SOUTH LOT X41 PROJECT# 1703.00 MODEL: "1542" GARAGE STFMG: RIGHT PAGE: MONOLITHIC FOUNDATION DETAILS/ SECTIONS ARCHITECT: STATE OF FLORIDA DEC 2t 2009 DATE: 12/23/09 SCALE:1/4 ?f=V_Of? SHEET Di OF 16 PANEL ANCHOR SEALANT L 3/81 -EXPANSION STRIP Q FREE OF MORTAR PANEL ANCHOR I' 1/4' EXP. BOLT TWO PER ANCHOR WALL FRAME SHOWN HERE FOR ILLUSTRATIVE PURPOSES ONLY. WALL FRAMING CAN BE CONCRETE, MASONRY, WOOD STEEL OR ANY OTHER STRUCTURAL SURROUND PANEL ANCHOR STYLE CONSTRUCTION SECURE 2xro MIN_ t0 BLK W/ (2) i4' ANCHOR BOLT W/ 2' WASHER SET IN SIMPSON HIGH STRENGTH EPDXY 4' EMBED. ❑® 9 91 U SECURE 2x4 ON FLAT TO BLK W/ CUT NAILS. SIDES: 2X6 GARAGE DOOR BUCK W/ (3) X'X8' J -BOLTS 4' EMBEDMENT MIN. W/ 2'X2'XYs WASHER AND NUT SPACED EVENLY FROM FLOOR TO GARAGE DOOR HDR IN JOINTS PRIOR TO FILLING. 1-2X6 PT BLOCK ® CENTER OF DOOR HEADER W/(1)}2'X8' J -BOLTS 4' EMBEDMENT W/ 2'X2'Aa' WASHER AND NUT GARAGE DOOR 3 BUCK ATTACHMENT SCALE: 1/2' =1'-0' 8 NOT USED LINTEL PLATE 3/8' EXPANSION STRIP FREE OF MORTAR LINTEL OSEALANT TO BE MIN. 1/2' DEEP SEE NOTE EXPANSION STRIP PANEL ANCHOR GLASS BLOCK NOTE: THIS DIMENSION IS DETERMINED BY THE ANTICIPATED DEFLECTION OF TE STRUCTURAL MEMBER ABOVE THE GLASS BLOCK. PANEL REINFORCING 6 EVERY OTHER BED JOINT MUST EXTEND THE ENTIRE LENGTH OF THE PANEL BUT NOT ACROSS EXPANSION JOINTS / GLASS BLOCK POSITION (2) 1-1/4' 5-4 HEX WASHER HEAD WITH ANTI -CORROSIVE COATING TIGHT TO BEND OF ANCHOR AND END OF SLOTTED HOLE TYPE S OR N MORTAR 1/4' MIN. 1/2' MAX. \ PANEL REINFORCING MORTAR ASPHALT EMULSION aO 1-3/4'X 20 GAUGE X 24" LONG GALVANIZED STEEL ANCHOR PANEL ANCHOR DETAIL 2X4 SECURED TO GABLE END W/(2)12dmEA. UPRIGHT 2X4 SECURED TO GABLE ENG W/(2)12d 61-81 O.C. LL -30 e GABLE BLOCKING TRUSS 2x4 BLOCKING A EA. RAFTER L-30 EA. RAFTER H2.5 EA. RAFTER 2x4 RAFTER a 24' O.C. 2x4 FRAMING (TYP) 4 FRAMED OVERHANG N.7.8. 2X4 DBL TOP PLATE 2x4 METAL STUD 24' O.G. 1/2' DRY WALL 2X4 16" O.C. MAX 2X4 PT. BT. PLATE 1/2' AB W/ MIN. 1' EMBEDMENT 2' D IA_ WASHER s+ 32' O.G. MAX 05 REBAR CONT. 9 �FRAME TO BLK.E: 1/2' =1'-0' SPARK ARREST 2'-4 1/2' PER MANUFACTURER IX2 Pt. TOP OF BOX — DBL. TOP PLATE c I 2X4 STUD �I II " TEXTURED FINISH OVER - PAPER BACK EXP. MET. LATH. W/ ON O.S.B. SHEATHING OR I' CDX PLYWOOD PRE. ENG. TRUSS 1 A PL SCALE: AN VIEW 1/2' = I' -0" SIMPSON H-5 (MIN.) 2X4 TO TRUSS PRE. ENG. TRUSS SP4 OR H-5 TOP PLATE TO STUDS 12'-0' ABV. 10'-0' LEVEL TO ROOF / -OR 2'-0' ABV. HIGHEST RIDGE WITHIN 10'-0' 2A SIMPSON H-5 (MIN.) m 2X4 TO TRUSS 1 CHIMNEY DETAILS PRE -ENG TRUSSES W/ TRUSS CONNECTOR VERIFY W/ FRAMING PLAN DOUBLE TOP PLATE CRIPPLE STUDS a I6' O.G. MAX SIMPSON LSTA-12 a EA. JACK STUD, BOTH SIDES OF OPENING. 2x STUDS A 16' O.G. MAX W/ SHEATHING. SHEATHING TO BE WITHIN J' OF WINDOW/ DOOR OPENING AND SECURE PER NAILING SCHEDULE KING STUDS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACKS (SEE HEADER SPAN CHART FOR DETAILS AND SPECIFICATION) JACK STUD ASSEMBLY t0 BE SECURED ONE PLY a A TIME. USE 12d NAILS, TWO WITHIN 6" FROM EACH END 4 NO MORE THAN 12' O.G. STAGGERED 61=4 OR H5 a TOP AND BOTTOM PLATES -8 EA. FULL LENGTH STUD, BOTH SIDES OF OPENING. SHEATHING TO LAP TO TOP OF MASONRY WALL. SHEATHING MUST NOT BREAK 1'-4' MIN. FROM 2ND TYP. EXTERIOR WINDOW/ FLR. LINE. 5DOOR OPENING WD FRAMED SCALE: 1/2' - l'-0' NAILING SCHEDULE ROOF DIAPHRAGM USE 1/16' O,SB. OR 1/2' CDX PLY WITH 08 RING SHANK GUN NAILS AT 4' O.C. AT SUPPORTED PANEL EDGES AND "8 RING SHANK GUN NAILS At 6' O.C. AT INTERMEDIATE SUPPORTS. SEE DETAIL. ROOF SHEATHING TO GABLE END FRAME USE 08 GUN NAILS A 4' O.G. EXTERIOR SHEATHING USE 1/16' 0.5B. OR 1/2' PLY WITH 08 RING SHANK GUN NAILS AT 6' O.G. AT PANEL SIDES AND 08 RING SHANK GUN NAILS 4' O.G. TOP 4 BOTTOM PANEL AND "8 RING SHANK GUN NAILS AT 6' O.C. AT INTERMEDIATE SUPPORTS. SEE DETAIL. NOTE: RING SHANK GUN NAILS SHALL BE PERMITTED AS AN ACCEPTABLE FASTENER FROM ANY MANUFACTURER NAL fREaUlREi" ENT6 SIZE HEAD LENGTH DIA. TENSILE STIR 8d ROUND, 100IFIED 11/8' J13 110,000 POUGH OPENINGS UP TO w-0. - go ,4 PRECAST L POUGH OPENINGS UP TO w-0. - go PRECAST SILL TOP CORD BLOCKING AT 4' ;t S F MING 11 SECURE 2x TO BLOCK W/ (2) &' TAPCONS OR DRIVE PIN (MIN SHANK SIZE .145) (MIN EMBED. 1 #") WITHIN V OF EACH ns END AND IV O.C. MAX en 2 SPACING. O.S.B. SHEATHING OR"' ' CDX PLYWOOD 2x4 BLOCKS CMU WALL TRUE MTS - '1/16' 2X4 BTM, PLA' 32, C TRUSS 2X4 DBL. TOP PLATE 2X4 STUD 16' O.C. OS.B. 1/2' A.B. W/ MIN. 1" EMBEDMENT LOCATE 6"-8" FROM ENDS AND 32' O.C. MAX. TEXTURED FINISH META -16 8' CMU WALL KNEE WALL DETAIL 2 TO BLOCK SCALE: 1/2' =1' -0" 6 ARCH WINDOW FRAME A SECTION SCALE: 1/2' Q I'-0' NOTE: TYP. EXT. SHEATHING ATTACHMENT FOR SHEAR 4 UPLIFT (O.S.B. TO BE STRUCTURAL GRADE) CONNECTORS FROM STUD TO PLATE ARE NOT REQUIRED EXCEPT a OPENINGS 9 @4'OC "8 RING SHANK GUN NAIL TOP 4 BOTTOM EDGES m N dy N �0 Z 2X4X4' SECURE t0 TRUSS W/ 3-12d 6'-8" O.C_ MAX TYP. 2X4 SECURE TO 2X4 BLK W/2 -12d SECURE TO BLK W/ META -16 2'-0" EXT: SCALE: 1/2' =1' -0' 08 RING SHANK GUN NAILS g 6" O.C. IN FIELD O.G. MAX. IN FIR t 2 RA ORT � • y Q TYP. EXT. SHEATHING ATTACHMENT FOR ROOF SPACES At EACH END. 10d �UTD,MODIFIED 2 I/8' .128 11000 z w � � SHEATHING (O.SB. TO BE STRUCTURAL GRADE) RAFTER OR TRUSS 9 d) NOTE: NSTAPLE, NAILF4 TOOL A550CIATIONT Z z 1 0.113 INCH NOMINAL SHANK DIAMETER ROOF SHEATHING � q �j 2 RING DIAMETER OF 0.012 OVER SHANK DIAMFTER a1 O d) 3. 16 t0 20 RINGS PER INCH 4.', 4 0.280 INCH FULL ROUND HEAD DIAMETER z= f, 5. 2 INCH NAIL LENGTH � Q 3� fLl BUILDING LENGTH L AND ENDWALL 5RAGING OR C ,43LE END FRAMING w 08 2' DECK SCREWS a 6'-8' O.G. MAX m EDGES 4 12' O.C. MAX IN FIELD. UNTHREADED SHANK t0 EXTEND BEYOND' THICKNESS OF SUB -FLOOR SHEATHING TYP. 3/4" T4G SUB -FLOOR DECKING= GLUED TO ALL EXPOSED MEMBERS OPT SERVIC PRE -ENG. TRUSS DBL. 2X TOP PLATE 2X BLOCKING 6 TOP OF 1/16' O.S.B. 2X STUDS 16' O.C. MAX. 2X BTM. PLATE Q 3/4' FLOOR DECKING�t PRE- ENGINEERED FLOOR TRUSS 2x4 a TOP 4 BOTTOM CONT. :��/" HETA-16 SLK. WALL O CONTINUOUS SHEATHING t0 BEGIN AT TOP OF BLK. W/ 1/4' GAP FROM BLK. TO O.S.B. O HORIZONTAL 2X S_PF. STRUCTURAL BLOCKING AT PERIMETER OF O.S.B. TO PROVIDE CONT. NAIL PATTERN O REMAINING AREA TO BE SHEATHED FROM DBL. TOP PLATE TO HORIZONTAL BLOCKING. ® SHEATHING a TOP OF WOOD FRAMED WALL TO BE STAGGERED MIN. OF 16' FROM SHEET BELOW Q INSTALL ALL SHEETS W/FACE GRAIN PARALLEL TO STUDS 11 EXT. WALL SHEATHING SCALE: 1/2'21'-0' A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SUBDIV. 8e LOT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 3dODEL: "1542" GARAGE SWING: RIGHT PAGE: MISC. DE'T'AILS ■sem ARCHITECT: STATE OF FLORIDA �`c �3 zoos DATE: 12/23/09 SCAT :1/4"=1'-0" SHEET D 2 OF' 2X4X4' SECURE t0 TRUSS W/ 3-12d 6'-8" O.C_ MAX TYP. 2X4 SECURE TO 2X4 BLK W/2 -12d SECURE TO BLK W/ META -16 2'-0" EXT: SCALE: 1/2' =1' -0' 08 RING SHANK GUN NAILS g 6" O.C. IN FIELD O.G. MAX. IN FIR t 2 RA ORT � • y Q TYP. EXT. SHEATHING ATTACHMENT FOR ROOF SPACES At EACH END. 10d �UTD,MODIFIED 2 I/8' .128 11000 z w � � SHEATHING (O.SB. TO BE STRUCTURAL GRADE) RAFTER OR TRUSS 9 d) NOTE: NSTAPLE, NAILF4 TOOL A550CIATIONT Z z 1 0.113 INCH NOMINAL SHANK DIAMETER ROOF SHEATHING � q �j 2 RING DIAMETER OF 0.012 OVER SHANK DIAMFTER a1 O d) 3. 16 t0 20 RINGS PER INCH 4.', 4 0.280 INCH FULL ROUND HEAD DIAMETER z= f, 5. 2 INCH NAIL LENGTH � Q 3� fLl BUILDING LENGTH L AND ENDWALL 5RAGING OR C ,43LE END FRAMING w 08 2' DECK SCREWS a 6'-8' O.G. MAX m EDGES 4 12' O.C. MAX IN FIELD. UNTHREADED SHANK t0 EXTEND BEYOND' THICKNESS OF SUB -FLOOR SHEATHING TYP. 3/4" T4G SUB -FLOOR DECKING= GLUED TO ALL EXPOSED MEMBERS OPT SERVIC PRE -ENG. TRUSS DBL. 2X TOP PLATE 2X BLOCKING 6 TOP OF 1/16' O.S.B. 2X STUDS 16' O.C. MAX. 2X BTM. PLATE Q 3/4' FLOOR DECKING�t PRE- ENGINEERED FLOOR TRUSS 2x4 a TOP 4 BOTTOM CONT. :��/" HETA-16 SLK. WALL O CONTINUOUS SHEATHING t0 BEGIN AT TOP OF BLK. W/ 1/4' GAP FROM BLK. TO O.S.B. O HORIZONTAL 2X S_PF. STRUCTURAL BLOCKING AT PERIMETER OF O.S.B. TO PROVIDE CONT. NAIL PATTERN O REMAINING AREA TO BE SHEATHED FROM DBL. TOP PLATE TO HORIZONTAL BLOCKING. ® SHEATHING a TOP OF WOOD FRAMED WALL TO BE STAGGERED MIN. OF 16' FROM SHEET BELOW Q INSTALL ALL SHEETS W/FACE GRAIN PARALLEL TO STUDS 11 EXT. WALL SHEATHING SCALE: 1/2'21'-0' A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SUBDIV. 8e LOT: TUSCA SOUTH LOT #41 PROJECT# 1703.00 3dODEL: "1542" GARAGE SWING: RIGHT PAGE: MISC. DE'T'AILS ■sem ARCHITECT: STATE OF FLORIDA �`c �3 zoos DATE: 12/23/09 SCAT :1/4"=1'-0" SHEET D 2 OF' FIBERGLASS SHINGLES 2x4 BLOCKING 5ETWEEN2x4 BLOCKING BETWEEN OVER #1E FELT PAPER ON FIBERGLASS SHINGLES TRU55E5 AT FIRST TWO 5A-T-5TRUSSES AT FIRST TWO SAYS O.S.B. SHEATHING OR 4'-0" O.G. CAT SHEATHING OVER #5 FELT PAPER ON 4'-0" O.C. (AT SHEATHING CDX PLYWOOD SECURED BEAMS) 16 O.S.B. SHEATHING OR z" SEAMS) PER NAILING SCHEDULE GDX PLYWOOD SECURED FRE -ENG GA5LE TRUSS PER NAILING SCHEDULE PRE -ENG GABLE TRUSS P.T. Ix2 W/ MTL. DRIP EDGE 2x4 NAILER MTL. URIfi�' EDGE CONT. 2x4 RAT RUN SECURED W/ (2) FIBERGLASS SHINGLES 2x4 5UB-RAND 126'5 e EACH TRUSS OVER #15 FELT PAPER ON ALUM. SOFFIT CONT. 2x4 RAT RUN SECURED 2x4 SUS -BAND TO BE INSTALLED MID. POINT OF O.S.B. SHEATHING OR �" UJ/ (2)126'o 6 EACH TRUSS ALUM. SOFFIT TRUSS SPAN, OR 10' = 0" O.C. MAX. PLYWOOD CDX PLOD SECURED STIFFBACK AT ALL UPRIGHTS TO BE INSTALLED �MID. PERYWONAILING SCHEDULE OVER 4'-10" HIGH (SEE POINT OF TRUSS SPAN, OR STiFFSACK AT ALL SEE ENERGY CODE FORMS SEALED ENG. FOR SIZE 4 10'-0" O.C. MAX. UPRIGHTS OVER 4'-10" FOR INSULATION R -VALUES. CONDITION.) _ . HIGH (SEE SEALED ENG. SEE ENERGY CODE FORMS FOR SIZE CONDITION.)° GYPSUM SOARp OR PRE ENG TRUSS SEE ENERGY CODE FORMS O.S.B. SHEATHING OR FOR INSULATION R -VALUES. 1 1�� HIGH STRENGTH CLG. FOR INSULATION R- VALUES. 16 0.5.}-3. SHEATHING OR 2 BOARD MTL. DRIP EDGE CDX PLYWOOD. ATTACHED„ I„ �� S GYPSUM BOARD OR Z CDX PLYWOOD. ATTACHED 2x4 NAILER 8 GYPSUM BOARD OR HIGH PER NAILING SCHEDULE ON HIGH STRENGTH CLG. PER NAILING SCHEDULE ON 2x4 SUS -SAND STRENGTH CLG. BOARD SHEET D5 BOARD SHEET D5 2x4 6 24" O.C. INTERIOR VENTED ALUM. SOFFIT GONG_ FILLED LINTEL BLK/S�� THICK, 3 COAT GEMENT GONG. FILLED LINTEL SLK -� KNEE WALL W/ (1) 05 REBAR CONTINUOUS PLASTER OVER GRADE - W/ C1) REBAR CONTINUOUS /$ THICK, 3 COAT CEMENT CONC. FILLED LINTEL BLK PLASTER OVER GRADE PRECAST LINTEL "D" FELT PAPER BACK "D" FELT PAPER BACK W/ (1) #5 REBAR CONTINUOUS TRUSS PLAN R-4.2 BATT, INSUL. EMBED. STRAP VERIFY W/ METAL LATH OVER R-4.2 BATT. INSUL. METAL LATH OVER APPROVED HOUSE WRAP PRECAST LINTEL APPROVED HOUSE WRAP PRECAST LINTEL WINDOW ATTACHMENT AS OR GRADE "D" FELT WINDOW ATTACHMENT A5 OR GRADE "D" FELT WINDOW ATTACHMENT AS z"THICK, 2 COAT CEMENT PER MANUFACTURES PAPER PER MANUFACTURES PAPER PER MANUFACTURES PLASTER APPLIED SPECIFICATIONS WEEP SCREED SPECIFICATIONS WEEP SCREED SPECIFICATIONS DIRECTLY TO MASONRY PRECAST SILL (SEE DETAIL 2)PRECAST SILL (SEE DETAIL 2) PRECAST SILL (1) *S REBAR VERTICALLY SECURE GA5LE TO 2x6 P.T_ (1) '5 RE5AR VERTICALLY SECURE GABLE TO 2xb P.T. PLATE W/ 126'5 S" O.C. MAX PLATE W/ 12d's 8" O.C. MAX (1) #5 REBAR VERTICALLY W/ CONC. POUR CELL W/ CONC. POUR CELL W/ CONC. POUR CELL I 1x2 P.T. FURRING STRIPS SECURE 2x6 PT. PLATE TO ( 1x2 P.T. FURRING STRIPS SECURE 2x(o PT. PLATE TO I° 1x2 P.T. FURRING STRIPS leo O.G. SLK W/ 2"x9" ANCHOR BOLT W/ ° 6 Iro" O.C. LK W/ "x9" ANCHOR BOLT W/ I(o" O.G. 2" WASHER SET IN SIMPSON 2" WASHER SET IN SIMPBON I 8 CMU 8 CMU S" CMU HIGH STRENGTH EPDXY "l : I HIGH STRENGTH EPDXY 7" I �� R P . t 1/2 GYP. WL:. BD. 1/2 GYP. WL. 5D. 1/2 GYP. WL. BD. i WOOD SASE EMBED. MIN. a6 32" OC MAX. WOOD SASE EMBED. MIN. 6 32 OC MAX. WOOD SASE 1' 1 Y_ ° �"TH ICK, 2 GOAT CEMENT ° 1 "THICK, 2 COAT CEMENT ° PLASTER APPLIED ° a PLASTER APPLIED aoe— te— 4 d 4d DIRECTLY TO MASONRY DIRECTLY TO MASONRY d I Lid a 1 -STORY GABLE 1 -STORY 1 -STORY GABLE W/ VAULT CLG. B LO C K WALL a BLOCK WALL IB B LO C K WALL 1 SCALE. 3/4"=V-0" 1 SCALE: 3/4'=I' -O' SCALE: 3/4" =1'-O" 2X4: ® 2X4: ® 2X4: SECURE t0 BLOCK W/ Y(6' SECURE t0 BLOCK W/ Y{e SECURE TO BLOCK W/Y4' TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN (MIN. SHANK SIZE .145 (MIN. SHANK SIZE .145 (MIN SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 MM. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4) MIN. EMBEDMENT 1 Y4') MIN. EMBEDMENT 1 Y4') WITHIN 8' OF EACH END 4 WITHIN 8' OF EACH END 4 WITHIN Be OF EACH END 4 IS' O.C. MAX SPACING. 18' O.G. MAX SPACING. 18' O.G. MAX SPACING. S' CMU 2X6: ® 2X6: ® 2X6: 15' DRYWALL SECURE TO BLOCK W/2—Y(6' NOTE: STRUCTURAL 2X MUST SECURE TO BLOCK W/2 -Y(6' SECURE t0 BLOCK W/1-1/4' NOTE: STRUCTURAL 2X MUST I"X4' OR 1'X2' P.T. NAILER TAPCONS OR DRIVE PIN BE ON OUTSIDE 4 SECURED TAPCONS OR DRIVE PIN NOTE: STRUCTURAL 2X MUST TAPCONS OR DRIVE PIN BE ON OUTSIDE 4 SECURED (MIN. SHANK SIZE .145 THROUGH NON-STRUCTURAL (MIN. SHANK SIZE .145 BE ON OUTSIDE 4 SECURED (MIN. SHANK SIZE .145 THROUGH NON-STRUCTURAL Ix4 P.T. OR %"X4' MIN. SECURE MIN. HEAD SIZE 300 %' TAPCON MIN. I Y4' MIN. HEAD SIZE 300 THROUGH NON-STRUCTURAL MIN. HEAD SIZE 300 Y(6' TAPCON MIN. 1--y4' THRU FRAME 4 EXTEND I Y4' MIN. EMBEDMENT 1 Y4') EMBEDMENT INTO BLOCK MIN. EMBEDMENT 1 Y4') V TAPCON MIN. I Y4" MIN. EMBEDMENT 1 Y4') EMBEDMENT INTO BLOCK INTO BLOCK W/ %&' TAPCONS WITHIN 8' OF EACH END 4WITHIN 8' OF EACH END 4 EMBEDMENT INTO BLOCK WITHIN Be OF EACH END 4 CDX OR DRIVE PIN 18' O.G. MAX SPACING. 8 CMU 18' D.G. MAX SPACING. 18' O.C. MAX SPACING. 8" CMU (MIN. SHANK SIZE .145 X' DRYWALL 8" CMU X' DRYWALL MIN. HEAD SIZE 300 2XS: ® I'X4' OR I'X2' P.T. NAILER J� DRYWALL TYVEK BUILDING WRAP MIN. EMBEDMENT I -Ya' SECURE TO BLOCK W/2-Y(v' SECURE BLOCK W/2 -W&' I'X4' BLOCK W/1-1/4' I'X4' OR I"x2' P.T. NAILER PAPER BACK WITHIN 8' OF EACH END 4 18' TAPCONS OR DRIVE PIN X' D.S.B. X 4' MIN. TAPCONS OR DRIVE PIN I X4 OR I X2 P.T. NAILER TAPCONS OR DRIVE PIN Z(b' D.S.B. X 4' MIN. O.G. MAX SPACING (MIN. SHANK SIZE .145 DOOR CASING (MIN. SHANK SIZE .145 DOOR CASING (MIN. SHANK SIZE .148 DOOR CASING GALV, D MTL. LATH DOOR CASING MIN. HEAD SIZE 300 IN. MIN. HEAD SIZE 300 MHEAD 81ZE 300 MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW TEXTURED DOOR JAMB OR WINDOW WITHIN 8' OF EACH END 4 ATTACH TO 2X PER WITHIN S' OF EACH END 4 ATTACH TO 2X PER WITHIN Be OF EACH END 4 ATTACH TO 2X PER FINISi-i ® WOOD ATTACH TO 2X PDER ETAILS. 18' O.G. MAX SPACING. MANUFACTURES DETAILS. 18' O.G. MAX SPACING. MANUFACTURES DETAILS. 18' O.C. MAX SPACING. MANUFACTURES DETAILS. MANUFAWOOD WEEP SCREED NOTE: SHIM AS NEEDED t0 PLUMB JAMB (DO NOT EXCEED 49 NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEEDY4') NOTE: SHIM AS NEEDED t0 PLUMB JAMB (DO NOT EXCEED Y4") NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4") CONSTRUCT I ON » DOOR JAMB TO BLOCK +3/4 OR +5/4 DOOR JAMB TO BLOCK +1-15/16 DOOR JAMB TO BLOCK +3 DOOR JAMB TO BLOCK +3-7/16 Q- WINDOW TO BLOCK +3/4 OR +5/4 WINDOW TO BLOCK +1-15 16" WINDOW TO BLOCK +3" WINDOW TO BLOCK +3-7/169' N A SCALE: I'm V -O' SCALE: I" =1' -0' SCALE: I' =1'-0" SCALE: I' =1'-O" S" CMU 2X4: ®2X4-. ® 2X4: ® 2X4: CEI SECURE TO BLOCK W/ Yfs SECURE TO BLOCK W/ Y(b' SECURE TO BLOCK W/ Y(6' SECURE TO BLOCK W/Y4' TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN 1/2" TEXTURED (MIN. SHANK SIZE .145 (MIN. SHANK SIZE .145 (MIN. SHANK SIZE .145 (MIN. SHANK SIZE .145 FINISHMASONRY MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 o MIN. EMBEDMENT 1 Y4") MIN. EMBEDMENT 1)4') MIN. EMBEDMENT 1 Y4') NOTE: STRUCTURAL 2X MUST MIN. EMBEDMENT 1 Y4") WITHIN Be OF EACH END 4 WITHIN 8' OF EACH END 4 WITHIN 8' OF EACH END 4 BE ON OUTSIDE 4 SECURED WITHIN S' OF EACH END 4 18' O.G. MAX SPACING. IS' O.C. MAX SPACING. 18' O.G. MAX SPACING. THROUGH NON-STRUCTURAL 18' O.C. MAX SPACING. 2X6: ® 2X6: ® 2X6: ® %' TAPCON MIN. I -Y4' 2X6: SECURE TO BLOCK W/2 -gift,' SECURE TO BLOCK W/2 -Y(6' NOTE: STRUCTURAL 2X MUST SECURE TO BLOCK W/2-3/(&' EMBEDMENT INTO BLOCK SECURE TO BLOCK W11-114- TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN BE ON OUTSIDE 4 SECURED TAPCONS OR DRIVE PIN TAPCONS OR DRIVE PIN NOTE: STRUCTURAL 2X MUST (MIN. SHANK SIZE .148 (MIN. SHANK SIZE .145 THROUGH NON-STRUCTURAL (MIN. SHANK SIZE .145 S" CMU (MIN. SHANK SIZE .145 BE ON OUTSIDE 4 SECURED WEEP SCREED MIN HEAD SIZE 300 MIN. HEAD SIZE 300 %' TAPCON MIN. 1-Y4' MIN. HEAD SIZE 300 DRYWALL MIN. HEAD SIZE 300 THROUGH NON-STRUCTURAL MIN. EMBEDMENT 1 Y4") MIN. EMBEDMENT 1 Y4') EMBEDMENT INTO BLOCK MIN. EMBEDMENT f Y4') I'X4' OR I'X2' P.T. NAILER MM. EMBEDMENT 1 Y4') gk" TAPCON MIN. I Y4' DETAIL c WOOD O WITHIN Be OF EACH END 4 WITHIN 8' OF EACH END 4 8 CMU WITHIN Be OF EACH END 4 WITHIN 8" OF EACH END 4 EMBEDMENT INTO BLOCK 18' O.C. MAX SPACING. 18' O.G. MAX SPACING. 18' O.G. MAX SPACING. 2ND 2X SECURE TO 18' O.C. MAX SPACING. 8' CMU X' DRYWALL STRUCTURAL MEMBER W/(2)12d 8" CMU 2X8: ® Ys' DRYWALL 2X8: ® 2X8: ® 2X8: ® J§' DRYWALL LOCK CONNECTION SECURE TO BLOCK W/2 -g4' SECURE TO BLOCK W/2-% SECURE TO BLOCK W/2-g/(b' 1 X4 OR 1X2 P.T. NAILER WITHIN 8 OF EACH END 4 6 SECURE TO BLOCK W/1-1/4' TAPCONS OR DRIVE PIN 1'X4' OR 1'X2' P.T. NAILER TAPCONS OR DRIVE PIN 1' P.T. X 4' MIN. TAPCONS OR DRIVE PIN t0 Be O.C. MAX TAPCONS OR DRIVE PIN I'X4' OR I'X2' P.T. NAILER SCALE: 1 1/2"=V-0" (MIN. SHANK SIZE .145 ---DOOR CASING (MIN. SHANK SIZE .145 DOOR CASING (MIN. SHANK SIZE .145 DOOR CASING (MIN. SHANK SIZE .145 1' P.T. X 4' MIN. MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 „ DOOR JAMB OR WINDOW DOOR JAMB OR WINDOW " DOOR JAMB OR WINDOW DOOR CASING MIN. EMBEDMENT 1 Y4 ) MIN. EMBEDMENT 1 Y4 J MIN. EMBEDMENT 1 Y4 J MIN. EMBEDMENT 1 Y4'J WITHIN S' OF EACH END 4 ATTACH 2X PER WITHIN 8' OF EACH END 4 ATTACH TO 2X PER WITHIN 8' OF EACH END 4 ATTACH TO 2X PER WITHIN 8' OF EACH END 4 DOOR JAM$ OR WINDOW MANUFACTURES RES DETAILS. MANUFACTURES DETAILS. MANUFACTURES DETAILS. ATTACH TO 2X PER IS'O.C. MAX SPACING. IS' O.C. MAX SPACING. 18' O.G. MAX SPACING. 18' D.G. MAX SPACING. MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED t0 PLUMB JAMB (DO NOT EXCEED 49 NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED )4') NOTE: SHIM AS NEEDED t0 PLUMB JAMB (DO NOT EXCEED Y4") NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4") DOOR JAMB TO BLOCK +1-1/2" DOOR JAMB TO BLOCK +2 1/4" DOOR JAMB TO BLOCK +3" DOOR JAMB TO BLOCK +3 3/4" B WINDOW TO BLOCK +1-1/2 D WINDOW TO BLOCK +2 1/4 F WINDOW TO BLOCK +3" H WINDOW TO BLOCK +3 3 4" SCALE: SCALE: 1' = I'-0' A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 Z�L4 Z SXMDIV. & IAT: TUSCA SOUTH LOT X41 PROJECT# 1703.00 MODEL: "1542" GARAGE SWING: RIGHT PAGE: MONOLITHIC 1- STORY WALL SECTIONS Sc NOTES ARCHITECT: STATE OF FLORIDA J1"C f3 209 CANTWELL 1012079 DAT: 12/23/09 SCALE: 1/4"=V-0 of SHEET D3OF�� FIBERGLASS SHINGLES OVER 1*15 FELT PAPER ON �6" 0.5.5. SHEATHING OR �" CDX PLYWOOD SECURED PER NAILING SCHEDULE PRE - ENG TRUSS MTL. DRIP EDGE 2x4 SUB -BAND VENTED ALUM. SOFFIT DOUBLE TOP PLATE WINDOW HEADER SIZE VARIES PER WINDOW OPENING SEE HEADER SPAN CHART FOR DETAILS D.S.B. SHEATHING OF, CDX PLYWOOD. ATTACHED PER NAILING SCHEDULE ON SHEET D5. THICK, 3 COAT CEMENT PLASTER OVER GRADE "D" FELT PAPER BACK METAL LATH OVER APPROVED HOUSE WRAP OR GRADE "D" FELT PAPER NOTE: SHEATHING MUST NOT BREAK 1'-0" MIN. FROM 2ND FLR LINE 2x4 CONT. 6 TOP AND BT. OF FLR TRUSS (TOP 2x4 SUPPORTS BT PLATE OF 2ND FLR, BT. 2x4 IS FOR WALL SHEATHING NAILER) WEEP SCREED (SEE DETAIL 2A) EMBED. STRAP VERIFY W/ TRUSS PLAN 21"THICK, 2 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 2- STORY FIRST FLOOR BLOCK SECOND FLOOR FRAME 1 SCALE: 3/4'=V-0" 2x STUDS 6 16" D.C. MAX W/ R-11 BATT. INSUL. MIN. 4" T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE PRE -ENG FLOOR TRU65 SIMPSON HETA-16 EMBED. STRAP e 32" O.G. MAX VERIFY W/ TRU55 PLAN $" GYPSUM BOARD OR HIGH STRENGTH CLG. BOARD EE ENERGY CODE FORMS OR INSULATION R -VALUES. " GYPSUM BOARD OF, 11GH STRENGTH CLG. BOARD WIST STRAP VERIFY W/ RUSS PLAN IJINDOW ATTACHMENT AS =ER MANUFACTURES SPECIFICATIONS JJINDOW SILL 2x STUDS a 16" O.C. MAX W/ ;R-11 BATT. INSUL. MIN_ 1" T 4 G SUBFLGGR GLUED 4ND NAILED AS PER 14AILING SCHEDULE PRE -ENG FLOOR TRUSS (INSTALL PER MFG. SPECS.) 8" GYPSUM BOARD OR 2" HIGH STRENGTH CLG. BOARD CONC. FILLED LINTEL BLK W/ (1) 05 REBAR CONTINUOUS R-4.2 BATT. INSUL. PRECAST LINTEL WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS PRECAST SILL (1) *5 REBAR VERTICALLY W/ CONC. POUR CELL 1x2 P.T. FURRING STRIPS 6 16" O.C. 8" CMU 1/2" GYP. WL. BD. 1 ----WOOD BASE O.S.B. SHEATHING OR �" CDX PLYWOOD. ATTACHED PER NAILING SCHEDULE ON SHEET D5 a"THICK, 3 COAT GEMENT —� PLASTER APPLIED TO METAL LATH OVER 2 LAYERS OF GRADE D BUILDING PAPER OR PAPER BACKED LATH OVER AN APPROVED HOUSE WRAP 2x4 CONT. 6 TOP AND BT. OF -' FLR TRU55 (TOP 2x4 SUPPORTS BT PLATE OF 2ND FLR, BT. 2x4 IS FOR WALL SHEATHING NAILER) WEEP SCREED IT (SEE DETAIL 2A) EMBED. STRAP VERIFY W/ TRUSS PLAN "THICK, 2 COAT CEMENT —� PLASTER APPLIED DIRECTLY TO MASONRY FIBERGLASS SHINGLES OVER #15 FELT PAPER ON '1/16" 0.5.8. SHEATHING OR "" CDX PLYWOOD SECURED PER NAILING SCHEDULE MTL. DRIP EDGE 2x4 SUB -BAND ALUM. SOFFIT 5TIFF5ACK AT ALL UPRIGHTS OVER 4'-10" HIGH (SEE SEALED ENG. FOR SIZE 4 CONDITION) SECURE 2x4 PLATE TO WALL W/ S"x6" THRU-BOLTS 6 32" O.C. MAX THEN SECURE GABLE TO 2x4 PLATE W/ 126's 8" O.G. MAX OR SECURE GABLE TO DBL TOP PLATE W/ SIMPSON HTC4 -s 24" O.C. MAX WINDOOW HEADER SIZE VARIES PER WINDOW OPENING SEE HEADER SPAN CHART FOR DETAILS 16 O.S.B. SHEATHING OR a" CDX PLYWOOD. ATTACHED PER NAILING SCHEDULE ON SHEET D5 THICK, 3 COAT CEMENT PLASTER OVER GRADE "D" FELT PAPER RACK METAL LATH OVER APPROVED HOUSE WRAP OR GRADE "D" FELT PAPER - NOTE: SHEATHING MUST NOT BREAK 1'-0" MIN. FROM 2ND FLR LINE 2x4 CONT. -8 TOP AND BT. OF FLR TRUSS (TOP 2x4 SUPPORTS BT PLATE OF 2ND FLR, BT. 2x4 15 FOR WALL_ SHEATHING NAILER) WEEP SCREED (SEE DETAIL 2A) EMBED. STRAP VERIFY W/ TRUSS PLAN '"THICK, 2 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 2 -STORY GABLE FIRST FLOOR BLOCK SECOND FLOOR FRAME --- SCALE: 3/4"=I'-0" 2x STUDS a 16" O.G. MAX W/ R-11 BATT. INSUL. MIN. i" T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE PRE -ENG FLOOR TRUSS �--" GYPSUM BOARD OR HIGH STRENGTH CLG. BOARD CONC. FILLED LINTEL BLK W/ (1) *5 REBAR CONTINUOUS FLOOR CONNECTION AT PARALLEL/ � PERPENDICULAR PRE �-ENG FLOOR TRUSS SCALE: 3/4 -1 0 WOOD CONSTRUCTION 2x4 BLOCKING BETWEEN TRUSSES AT FIRST TWO BAYS 4'-0" D.G. (AT SHEATHING SEAMS) PRE -ENG GABLE TRUSS CONT. 2x4 RAT RUN SECURED W/ (2) 12&s e EACH TRUSS SEE ENERGY CODE FORMS FOR INSULATION R -VALUES. i" GYPSUM BOARD OR HIGH STRENGTH CLG. BOARD DOUBLE TDP PLATE WINDOW ATTACHMENT AS PER MANUFACTURER SPECIFICATIONS WINDOW SILL 2x STUDS 6 16" O.G. MAX W/ R-il BATT. INSUL. MIN. 4" T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE FRE -ENG FLOOR TRUSS ( INSTALL PER MFG. SPECS.) J" GYPSUM BOARD OR HIGH STRENGTH CLG. BOARD CONC. FILLED LINTEL BLK W/ (1) 05 REBAR CONTINUOUS PRECAST LINTEL WINDOW ATTACHMENT AS PER MANUFACTURER SPECIFICATIONS PRECAST SILL (1) 05 1RE5AR VERTICALLY W/ CONC. POUR CELL 1x2 P.T. FURRING STRIPS 6 16" O.C. 8" CMU 1/2" GYP. WL. BD. WOOD BASE 1/16" O.S.B. OR �' GDX -TYVEK BUILDING WRAF PAPER HACK -GALV'D MTL. LATH -1/8" TEXTURED FINISH 6 WOOD -WEEP SCREED zQ 8" CMU 1/2" TEXTURED FINISH 6 MASONRY WEEP SCREED DETAIL @) WOOD TO "'� 2 A LOCK CONNECTION SCALE: 0 A R C H I T E C T S 1 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 SVHDIV. 8e LOT: TUS C A SOUTH LOT X41 PROJECT# 1703.00 MODEL: "1542" GARAGE STfMG: RIGHT PAGE: MONOLITHIC 2 -STORY WALL SECTIONS ARCHITECT: STATE OF FLORIDA PEC 2 '? LL IDATE: 12/23/09 SCALL:1/4"-1'-0" SHEET D4OF�(0 *NOTE: NAIL SHEATHING TO ALL 2X AS PER EXT. SHEATHING NAILING, ad 4" O.C. r IAX e EDGES 4 6"-S" O.G. MAX IN THE FIELD PRECAST HEADER(MIN) 2 X 4 (MIN 2 X 3) 1-3/16 TAPCON DBL. TOP PLATE OR DRIVE PIN (MIN SHANK SIZE.145 SECURE 2 X RIP TO FIT MIN HEAD SIZE 300 DBL. TOP PLATE W/2-12dS 6'-B' O.C. MAX. MIN EMBEDMENT 1 1/41) 2X4 16' O.G. MAX. 1/8" TEXTURED FINISH 8' FROM EACH END AND 18'x= 1/16" OSB SHEATHINGO.C. MAX. MIN 1-1/4' EMBEDMENTiZ 2 X 6 (MIN 2 X 3) 2-3/16 TAPCONN? 2 X 4 16' O.C. MAX. OR DRIVE PIN (MIN SHANK SIZE.145�:� (WHEN OVER 16' IN HIEGHT.) MIN HEAD SIZE 300 SECURE 2x4 W/ 2-W6' TAPCONS OR DRIVE PIN 2 X 4 (WHEN OVER 16' IN HIEGHT.) MIN EMBEDMENT 1 I/4" 8' FROM EACH END AND 18'' (MIN. SHANK SIZE .145 MIN. 1/4" TEMPERED MASON ITE O.C. MAX MIN 1-1/4' EMBEDMENT HEAD SIZE 300 MIN. GLUE 4 NAIL W/Sd'S S'-12" O.C. 2 X 8 (MIN 2 X 3) 2-3/16 TAPCON EMBEDMENT 1 Y4' WAN 8' EA. END NOT TO EXCEED IF NEEDED. OR DRIVE PIN (MIN SHANK SIZE.145 IS' O.G. MAX 7 BT. PLATE 2 X SOLID BLK'G ARCH MIN HEAD SIZE 300 2X4 SOLID BLOCKING SECURE W/2 -12d EACH END MIN EMBEDMENT 1 1/41) SECURE TO SHEATHING W/ 8' FROM EACH END AND 18' MIN. 2-12d PER BLK EA. ENDJL In ATTACHMENT PER MANUFACTURER'S SPECS. O.C. MAX MIN 1-1/4' EMBEDMENT '1/16' OSS SHEATHING DBL. TOP PLATE 2x4 16' O.C. MAX SECURE 2X4 TO WOOD W/2 -12d 0 6"-8' O.G. STAGGERED SECURE 2X4 W/ 2-W6' TAPCONS OR DRIVE PIN (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4' WAN 8' EA. END NOT TO EXCEED 18' O.G. MAX 2X4 SOLID BLOCKING SECURE TO SHEATHING WITH MIN. 2-12d PER BLK. EA. END 3 EXTERIOR ARCHWAY CMU WALL ARCHWAY DETAIL 1 16" AND UNDER SCALE: i/2"■1'-0' lO. Yip,' O.S.B. ORY' PLYWOOD SHEATHING 2O 015 BLDG. FELT O3 24' WIDE 26 In GALVANIZED METAL FLASHING MUST ADD D1910, 36' WIDE AND AND MUST BE A MIN 24' WIDE METAL. 0 FIBERGLASS SHINGLES P - B TRUSS 1/2' CLG. BOARD 4 TEXT. SIMPSON SP4 2X4 DBL. TOP PLATE EVERY f-1/2" DRYWALL OTHER STUD 2X4 WOOD STUDS e16' O.G., U.N.O. ON TRUSS PLAN 2X4 CONT. STRESS BLOCKING MID -WALL 2X4 PT. PLATE SIMPSON 6104a 32' O.C. MAX 1/2'X9' A.B. 32' O.C. 1' EMBEDMENT e CONG. SLAB 2 05's CONT. 1 -STORY @INT. BEARING WALL SCALE: 1/2' ■ i'-0" NOTE: FOR WALLS W/NO UPLIFT OR HAS FLOOR LOAD ONLY, DO NOT INSTALL CONNECTORS. 2X4 SOLID BLOCKING SECURE TO SHEATHING WITH MIN. 2-126 PER BLK EXTERIOR ARCHWAY EA. END WITH WINDOW SCALE: I/2"=1'-0' PRECAST HEADER(MIN) 2 X 4 (MIN 2 X 3) 1-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 MIN EMBEDMENT 1 1/41) 8' FROM EACH END AND 18' O.C. MAX. MIN 1-1/4' EMBEDMENT 2 X 6 (MIN 2 X 3) 2-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 MIN EMBEDMENT 1 1/4') 8' FROM EACH END AND 18' O.C. MAX MIN 1-1/4' EMBEDMENT 2 X 8 (MIN 2 X 3) 2-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 1/16' OSB SHEATHING MIN EMBEDMENT 1 1/41) 2X4 16' O.C. MAX. 8' FROM EACH END AND 18' (WHEN OVER 16' IN HEIGHT.) O.G. MAX MIN 1-1/4' EMBEDMENT 2X4 SOLID BLOCKING SECURE TO SHEATHING W/ MIN. 2-12d PER BLK EA. END (�'WAYDETAIL 4 AND UP SCALE: 1/2'=1'-0' ri�CLOSED VALLEY FLASHING DETAIL N.T.5. PRE -ENG TRUSS DOUBLE TOP PLATE 2x CONTINOUS STRESS BLOCKING MID WALL 2x STUDS a ib' O.G. MAX J' T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE 15T FLOOR STUDS TO 2ND FLOOR STUDS SIMPSON MSTA-36 32' O.G. MAX PRE -ENG FLOOR TRUSS DOUBLE Top PLATE 2x CONTINOUS STRESS BLOCKING MID WALL 2x STUDS m 16' O.G. MAX 1/2' GYP. WL. BD. SECURE BT. PLATE TO SLAB W/ �'x9' ANCHOR BOLT W/ 2' WASHER SET IN SIMPSON HIGH STRENGTH EPDXY 1' EMBED. MIN. 8IMPSON 8P4 * 32' O.C. MAX ►� INT. 2 -STORY L. B. W. SCALE: I/2' =1'-0' PRE -ENG TRUSSES OR CONY. FRAMED RAFTERS ' O-S.B. SHEATHING OR CDX PLYWOOD SECURED PER NAILING SCHEDULE 2x4 BLOCKING UNDER WALL STUDS SCURE BETWEEN TRUSS BAYS W/ (3) 12d's EACH END 2x DOUBLE TOP PLATE STUDS w 16' O.G. MTS -12 a EVER STUD 2X4 Bt. PLATE DORMER @)AT- T ACHMENT SGAL E. 1/2' ■ 1' - 0' d� MTL WDW FRAME *NOTE: NO GAP A WDW FRAME TO EXCEED 1/4' ARCHWAY DETAIL A CUTAWAY SCALE: 2 X 4 (MIN 2 X 3) 1-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 MIN EMBEDMENT 1 1/4') 8' FROM EACH END AND 1S' EXISTING BLK ABY. O.C. MAX. MIN 1-1/4' EMBEDMENT I/4' TEXTURED FINISH 2 X 6 (MIN 2 X 3) 2-3/16 TAPCON 1/8' TEXTURED FINISH OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 -1116'055 SHEATHING MIN EMBEDMENT 1 1/4') MAX. 16' D.C. 4 X 2 8' FROM EACH END AND 18' 2 X 4 OVER 16' X HEIGHT) O.C. MAX MIN 1-I/4' EMBEDMENT 2 X 4 (WHEN OVER 16' 2 X 8 (MIN 2 X 3) 2-3/16 TAPCON 1(o' IN HEIGPT.) OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 2 X SOLID BLK'G ARCH MIN EMBEDMENT I I/4') SECURE W/2 -12d EACH END 8' FROM EACH END AND 18' ATTACHMENT PER O.C. MAX MIN 1-1/4' EMBEDMENT MANUFACTURER'S SPECS. MTL WDW FRAME 1/4' TEMPERED MASONITE •NOTE: NO GAP WDW FRAME GLUE 4 NAIL W/8d'6 8'-12' O.C. TO EXCEED 1/4' IF NEEDED. ARCHWAY DETAIL B CUTAWAY SCALE: 1/2' = I' - 0' ASPHALT SHINGLES OVER • 15 FELT ON 1/161 O.S.B. PRE -ENG GABLE TRUSS SPF STIFFBACK (SEE SEALD ENG. PACK FOR SIZE 4 CONNECTION) 2x4 SPF BLOCKING BETWEEN TRUSSES AT FIRST TWO BAYS 4'-0' O.C. (AT SHEATHING /.r Av i I�r � I�tAI `� SECURED W/ C2) 12d's EACH TRUSS (2) 2x4 02 S.Y.P. DIAGONAL BRACE W/ (3) 12d's 41 EACH TRUSS (DIAGONAL X -BRACING TO COVER 5-TRU5SE5 B' GYPSUM BOARD OR HIGH STRENGTH CLG. NOTE: BOARD DIAGONAL BRACE a CENTER OF TRUSS SPAN OR HIGHEST RIDGE. DIAGONAL BRACE TO BE m ANY SPAN 15'-0" OR GRATER REFER t0 TRUSS ENG. FOR ADDITIONAL HORIZONTAL TRUSS REINFORCEMENT. 0'-0' TO 30'-0" (1) X -BRACE 30'-1' TO 60'-0' (3) X -BRACE (1) X -BRACE a CENTER AND (2) BRACE DIVIDED EQUALY FROM CENTER TO END GABLE X -BRACING SCALE: 1/2' =1'-0' 2x RIDGE ONE SIZE LARGER THAN RAFTER SIZE MIN. (3) 126 NAILS OR MIN. (4) 10d GUN NAILS Ixb COLLAR TIE AT EVERY OTHER RAFTER W/ MIN. (3) 12d NAILS OR MIN. (4) 10d GUN NAILS 2x RAFTERS Ix8 NAILER SECURE TO TRUSSES BELOW W/ (2) 12d NAILS OR (3) 10d GUN NAILS a EA. TRUSS RAFTER TO TRUSS MTS -12 CREATE VOID FOR STRAP PENETRATION. ROOF DECKING OVER PRE -ENG TRUSSES PRE -ENG. TRUSS. ALTERNATE CONNECTION MSTA-24 RAFTER TO BLK'G BETWEEN TRUSSES CONV. FRAff�DR�OOSCLEI 0'-0' TO 30'-0' (1) 'X' BRACE 30'-1' TO 60'-0' (3) 'X' BRACE (I 'X' BRACE 0 CENTER) (2 'X' BRACE DIVIDED EQUALY FROM CENTER TO END) FIBERGLASS SHINGLES OVER —� M 15 FELT ON 1/16' 0.5.8. (2) 2X4 02 SYP DIAGONAIL BRACE —� W/ 3-126 o EA TRUSS C DIAGONAIL BRACE TO COVER 5 -TRUSSES 2X4 BLOCKING FIRST 2 BAYS AT SHEATHING SEAMS (2) 10d NAILS EA END TO TRUSS SPF STIFFBACK (SEE SEALD 1=NG. PACK FOR SIZE 4 CONNECTION) 1/16' OSB SHEATHING USE 8d NAILS AT 4' o c. EDGE 4 6' o c. FIELD 2X4 W/ 3/8' X 5 LAG 032' O.C. MAX. OR SIMPSON M5TA-24 ® 32' O.C. MAX. i SHEATHING NAILING TO BE 6'-8" O.C. IN FIELD 4" O.C.®ALL EDGES W/Sd NAILS SCALE: 1/2'-V-0" FINISH 6 LANDING 3/4" PLYWOOD F.F. DBL 2X6 F% COMMOM TRUSS 24' o.c. 1/2" CLG. BOARD NAIL CONT. RAT RUN TO TRUSS W/ (2) 12d A EA. TRUSS 2X4 SYP RAT ADJACENT TO DIAGONAL BRACE. DBL TOP PLATE 2X4 STUD 16' O.G. MAX. " 1115 UPLIFT SIMPSOM HTSM20 W/10 10d TO TRUSS AND (4) 1/4' x 2 1/4' TAPCONS TO CONT POURED LINTEL M 2350 UPLIFT (2) SIMPSOM HTSM20 ONE EA. SIDE OF TRUSS OPPOSITE SIDE OF BLOCK W/10 10d TO TRUSS AND (4) 1/4' x 2 1/4' TAPCONS TO CONT -POURED LINTEL PRE -ENG TRUSS CONTINUOUS BOND BEAM TAP CONS MIN. 2' COVER 2' APART 12 TRUSS ANCHOR RETROFIT N.T.S. 1 3/4" PLYWOOD WITH LANDING DETAIL 4 12-D COMMONS „ NAILED THRU 3/4 FINISH s LANDING PLYWOOD INTO 3/4” PLYWOOD F.F. EACH STfiZINGEi� 3-2x12 SYP STRINGER ' DBL 00 2X12 REINFORCED W/2X4 SPF OR JOIST W/CONT. BEAD OF SUB -FLOOR ADHESIVE PL -400 OR SIMILAR ,@ EA HORIZONTAL RUN SECURE TREADS TO STRINGER W/(3)08 3" SCREWS 6 EA STRINGER, UNTHREADED SHANK TO EXTEND BEYOND THICKNESS OF SUB -FLOOR SHEATHING NOTE: STAIRS RISERS TO CONFORM TO F5C 2001 2R+1T=24"-25" 3/16" MAX. VARIATION IN RISERS/TREADS ADJACENT TO EACH OTHER 3/8" MAX. VARIATION IN ANY RISER/TREAD HANDRAIL CIRCULAR CROSS SECTION DIA. TO BE 13/4" +-1/4" OR PROVIDE EQUIVALENT GRASPABIL ITY WINDERS MIN. 6" WIDE NARROW END MIN. 11" WIDTH 6 12" FROM NARROW END 34" MIN. HANDRAIL HGT. 36" MIN. FINISH WINDER DETAIL 2X12 TREAD GUT TO F IT _-1X8 RISER 101 , 112 U� m (3) 106 CUT NAILS 6 2 X4 P.T. SLEEPER INTO SLAB LESS THAN 4" T`I'P. BETWEEN SPINDLES HAND RAIL 1/2" DRYWALL-,, 1X10 TRIM -1' NOSING TYP. 3�STAIR SECTION DETAILS SCALE: 3/4-=V-0. A R C H I T E C T S / Design Group,nc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 StTBDIV- 8c LOT: TUSCA SOUTH LOT X41 PRO JEC T# 1703.00 MODEL: 1542 GARAGE SWING: RIGHT PAGE: misc. DETAILS ARCHITECT - STATE OF FLORIDA DATE: 12/23/09 SHEET