HomeMy WebLinkAbout3508 Orlando Dr (a)U r Q
— — — — — -. --- opt _
rn j
I SELECTIVE OUTSIDE. STORAGE
Y V
z 1l
P:a.T3�' S 25.29'57"-W 149.83' MEAS
{ 5 25'30 N 150.00' DEED 1
{ i
RUhS FROUI ;RrIQNV
WO '9L.CK 3 i err+
(PUMPNC/'Li
�L F - t5"
Kj i
E
� CONC.
PARKISG
i
I
i 1
�� 1
Q
'
G R A P --ITC SCALE 1
imiiNgfm PF 04 A- I
7 ( k 1
f=
Q 0' 1 .� 0' b 0' • ID 0' . 1
i
SCALL _ 30 1
I
CONC.
PriRXI NG
P.O.G.
r
C "rE Wu ETA
t
It
8�A,,
'^r U
Cri-,-noo Drive
.` GG'+'� 0'1•'7 `_ �f;_'': C7ti�'�, f� a V
niF Suntcrj, F'cr;da :3277.3
`'\ z 4 I
oa �
[ , I 26.59 12' YCLiui uiAG Nh+ STRIP:N6
M.
ACCEiS EASEMENT---._�
\y I 7:4•
'r ----
t 12.8•
DEED` ^149.64' !AE�,S k
" J SAWARY MANHOLE
—
—TOP R(M - 47.63
N'Lr )N'V 4' PVC = 43.93
ac
VFr 5'WON
7"'
�`•y-�y,�. roP of awrc
L6/P
LP
PARXINC ` BOLLAR S : rYP) '
25 RE�J(RE�
s�z5•.�a' 256.00' FEED�
S 25`29'18" W 256.00' MEAS
I
1
EX I•ST I NG SONNY' S BAR—B-.-WE
3506 Orlando Drive
Sanford, 'Florida 32773
TOTAL LAND AREA: Total Sonny's Site 1. 1578 Ac,
OPEN GREEN SPACE: 25% (0.2895 Ac, )
IMPERVIOUS AREA: 75% ( 0. 8684 Ac, )
SONNY'S PARKING REQUIRE N`ENTS:
204 seats @ 0.4 spaces/seat = 82 spaces required
Total Parking Spaces Provided = 82 spaces
TAX PARCEL NUMBER: 11-20-30--300-0130-0000
_256.00' DEED _ 256.01' MEAS
FEDERAL HIGHWAY 17 & 92. R/W 180'
-- 8/21/98 REVISED. J.E.F.
BOULEVARD ^� 10/239$ RNSO J..F:
FZ
c a
4-4
PROJECT SITE
+' j n
4s ' n L� x
ACE MARY 13OULEVARO
t.
�
VICINITY MAP a .- �4
I
N. T, S,
c
SITE BATA a
d � i
OWNER: Ba!) les Properties, Inc.
6212 Dartmoor Court ce) z °°
Ort ando, F (or i da 32819 ; C,
( 407) 851-0000 L u
Yui a 2 1
Con tac t. Mr. Char les Ba i les, Jr,/'- TM�
CONT RAC TOR: C. W, Bankston Construction Cor�pany, IrFC• �� < -- � Q'r
5929 Anno Avenje '
Or t anao, F t or i da 32809�v�YWr
Y (Sy
( 407) 851-2760 I
Contact: Mr, J i M Bankston
ENGINEER: Frith & Associates, Inc: Sanford Firs Priv DI
88'-1 Great Cove Drive
I
I
Orlando, Florida 32819 Date:- 1
4-7
( 407) 363--0739
Contact: Mr. John Fri th, P. E.
I
SURVEYOR: Acc=fright Surveys of Ortando, Inc, PERNI
r i,
I
2012 E. Robinson Street
I
Ortandc, Florida 32803
( 407) 894--6314
I
Contact: Ni-. Frank A, Raymond, P. L., S.
UTILITIES: Power: Florida Power & L i ghfi
Water: City of SanFord
Sewer; City of Sanford L c l
Te lephonel United Te t.ephone
Sctid Waste: City of Sanford ®=
l .I
LAND AREA: To to t Site 4. 6419 Acres
I
ZONING: �. �:• "'�
S' Front: 25 f t.
SETBACK..: � .
��..': DC7.. •,I
S i de; 10 F t.
Rear: 20 f t,. U . d C>
.+►_.LJ �.
o '
PARKING REQUIREt`tENTS ' 00 1)., ' .1
Apartment: 2 bedroom @ 2 spaces/apt, 2 spaces in (D
t OFF i ce: 400 s, f, @ 1 space/200 s. f, = 2 spaces. (1r) "':z
To -tat parking required = 4 spaces cn.
Total parking provided = 5 spaces
PARKING SPACE SIZE, 20' x 10' - Standard 4 spaces L.L.. 'i
20' x 12' - Handicap 1 space
UPON GREEN SPACE: 26. 54'l• (1 2319 Ac. >
I MPER`1 I OU S" AREA: 73. 46% C 3, 4100 Ac. )
fn I
LEGAL BCSCI, RIPTION
i
COMF�tE,NiC 18.91 CHAINS WEST ANL`' 8.23 CHAINS NORTH OF THE S.E. p w
CORNER OF THE N. E, 1/4 OF THE S.E. 1/4 OF SEC. 1 1, T1NP. 20 S., R;v,,
30 E(SEt;!,' 0XE COUNTY, FLORIDA THENCE RUN N. 64' 3C' W., 570.81'
TO THE POINT OF' BEGINNING, THENCE RUN N. 64'30' W., 89, 16' THENCE
RUN N. 25' 30' W. 600.66'; THENCE RUN S.64' 30' E•, 313.90', THENCE
RUN S. 2=)' 30' W. 256.00' Tr�EPJCE RUN S. 64' 30', • 197.00' TO THE 4
WESTERLY RIGHT-"-OF-b"SAY LINE OF STATE ROAD 15/600, THENCE RUQ,' S_ 25' U
30' W., ALONG SAID RIGHT -OF -WAY LINE OF STATE ROAD 15/600, CI J
194.66' THENCE RUN N• 04'30' W., 44!.71', THENCE RUN S. 25' 30"
W., 150' TO THE PCIPIT OF 8EGINNIN%.
CONTAINS: 202202 SQUARE FEET OR 4.6419 ACRES MORE OR LESS. a'
CL 0
GENERAL NOTES: `� U
U
I. THE UNDERGROUND UTILIPES SHOWN HAVE BEEN LOCATED' �
FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. L � a 1+, E,�
.S� v
THE SURVEYOR 'MAKES NO GUARANTEE THAT THE UNDER— tn
� "' � „
CROUND UTILITIES SHOWN COMPRISE 05
ALL SUCH UTILITIES
, , E, ._Iq b DRAM
10
IN Tf"1L. AREA, EITHER IN SER 1ICE OR' ABANDONED. r l tE � � � � ' � ! AF
SURVaYOR FURTHER DOES NOT WARRANT THAT THE UNDER- tri -j ►A
•ba CHECKED
GROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION Q i.. .¢ r� o
INOICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE. U Q . JEF
LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION o ?'.•.•zo o VAT
A'✓AILABLE, THE SURVEYOR HAS NOT PHYSICALLY LOCATED " b Ia.
=: ^ -.1
THE UNDERGROUND UTILITIES. Q Q 'z. cir
2.. THIS SITE IS LOCATED IN FLOOD ZONE C, BASED ON FLOOD
INSURANCE RATE MAP, PANEL NO. 120.294 ' 0045 E,:
CITY OF SAINIFORD, FLORIDA.
97 012
SHEET ' '
J. ELEVATIONS BASED ON NGVD DATUM, BENCHMARK � RM 1.3
ELEVA FION BEING 47-32 FEET MEAN ' SEA LEVEL.
4. FUTUREBUILDI(1G SLABS TO 5E USE FOR OUTSIDE F'ARKiIvG. `qE. •: '
5. OFFICE Ar10 APARTMENT ARE FOR PROPERTY MANAGER ONLY. � ^4���t �
`�... O s�,cers �1
i
..._............ . . ,...«........ .. .__. ..__-.. C4.1,f,r,a/kvl'-.IY+P•Ahv!1w.':rY.,V ,irbrxM^v,Vµ%nk•w,:,,,.»—..
.._.........,r.,-..........w+n,,r»....»u:.'.,nz..:rr;Km,nr.vw'...,e......."-...r-.....v...�....._.... e.0 r...r.w..,:n an a ...:.:::. u!V.w.w,....- .w,a ,., ... .iw :.n. r,r:e. 'u.««,.vw.a., w... wm,. .....,.,t....•.... _" .... ,"—.,.... .. .:..i..c:xwr ut rw ..Yarxt*^^'t. ,x +r:u rtx nN-nr "WFW:.n..pNl x.w:yximrv,r .w! AeHtt,.. • u .' r «.. .—....
Construction Plans
A
Typical Abreviations
K
K Kip
L
AB
Anchor Bolt
ABV
Above
ACI
American Concrete
Institute
ADD'L
Additional
AFF
Above Finish Floor
AGGR
Aggregate
AISC
American Institute of
Steel Constrcution
AISI
American Iron and
Steel Institute
AL
Aluminum
ALT
Alternate
ARCH
Architect(ural)
ASTM
American Society of
Te ting Materials
AWS
American Welding
Society
B _
Bottom Of
BB
Bond Beam
BLDG
Building
BL W
Below
BM
Beam
BOT
Bottom
BP
Base Plate
BRDG
Bridging
BRG
Bearing
BRK
Brick
BS
Both Sides
BTWN
Between
C
C/ C
Center to center
CANT
Cantilever
CB
Concrete Beam
CC
Concrete Colum
CFS
Cold Formed Steel
CIP
Cast -in -Place
CJ
Construction /
Control Joint
CL
Center Line
CLR
Clear(ance
CMU
Concrete Masonry
Unit
COL
lColumn
CONC
Concrete
CONN
Connection
CONT
Continuous
CONT
Contractor
CTR
Center
CTR'D
Centered
CY
Cubic Yard
C
DIA
IDiameter
DIAL
IDiagonal
DL
Dead Load
DN
Down
DTL
Detail
DWG
Drawing
D WL
Dowel
F
EA
Each
EE
Each End
EF
Each Face
EJ
Expansion Joint
ENG
lEngineer
EOS
Edge of Slab
EL
Elevation
EQ
Equal
EQ S
Equal Space(s) (ing)
FS
Each Side
EW
Each Way
EXP
Expansion
EXT
Exterior
F
F _
Face Of
FDN
IFoundation
FF
Finished Floor
FL
Floor
FLG
Flange
FMC
Framing
FS
Far Side
FT
Foot
FTG
IFooting
A
GA, g
auge
GALV
Galvanized
GB
Grade Beam
GC
General Contractor
GFC
Grout Filled Cell(s) /
Coarse
GR
Grade
I
HORIZI Horizontal
HP High Point
HS Headed Stud
HSS Hollow Structural
Section
I
Long
ID
jInside Diameter
IF
Inside Face
INT
Interior
J
Long Point
JST
Joist
JT
lJoint
LG
Long
LL
Live Load
LNTL
Lintel
LONG
Longitudinal
LP
Long Point
M
MAS
Masonry
MAX
Maximum
MB
Machine Bolt
MBM
Metal Building
Manufacturer
MC
Moment Connection
MCJ
Masonry Control
Joint
MECH
Mechanical
MEZZ
Mezzanine
MFR
Manufacture(er)
MIN
Minimum
MISC
IMiscellancous
MO
Masonry Opening
MS
Metal Stud
MTL
Metal
N
NTS INot to Scale
0
OA
Overall
OC
On Center
OD
Outside Diameter
OF
Outside Face
OH
Over Head
OPNG
Opening
OPP
Opposite
Is
PAF
Power -Actuated
Fastener
PF_MB
Pre -Engineered
Metal Building
PERP
Perpendicular
PC
Precast
PL
Plate
PLF
Pounds per
linear Foot
PI_YWD
Plywood
PNL
Panel
PSF
Pounds per
Square Foot
PSI
Pounds per
Square Inch
PTN
Partition
IM
R
Radius
RC
Reinforced Concrete
REF
Reference
REINF
Reinforce(d) (ing)
REQ
Require
REQ'D
Required
RF
Roof
RP
Radius Point
RTN
Return
RW
Retaining Wall
111
SCH
ISchedule
SECT
Section
SHT
Sheet
SIM
Similar
Si
Sawcut Joint
SJI
Steel Joist Institute
SL
Slope
SP
Space(s)
SPECS Specifications
SQ
Square
SSL
Short Slotted
STD
Standard
STIFF'
Stiffener
STL
ISteel
STIR
Strength
STRL
Structural
SW
Short Way or
Shear Wall
STMM
Symmetrical
T
T&B
ITop & Bottom_
TB
_
Tie Beam
TC
Tie Column
TDS
Turned -Down Slab
TEMP
Temperature
THK
Thick
THNS
Thickened Slab
TOP'G
Topping
TYP
Typical
T/
Top Of
U
UNO Unless Noted
Otherwise
V
VERT lVerticul
W
WD
Wood
WF
Wall Footing
WO
Window Opening
WWF
Welded Wire Fabric
1-W—/1
With
35'
SOUTH SANFORD
SE F STO-R-A-GE
SANFORD, FLI
9'-3" 171'-6" 9'-3"
� I 1
3 3 9 9'-3"
jj : j33 iii
7 j 7
20' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' 10' x 20' I 10' x 20' ! 10' x 20' 10' x 20' 20' x 20'
3
11 —6
29'-10" 79' 8" I 79'-10"
I
1 1 3
20' x 15' 10' x 15' '10' x 15' 10' x 15' 10' x 15' 10' x 15' 10' x 15 10' x 15' ' 10' x 15' 10' x 15' 10' x 15' 10' x 15' 10' x 15' ' 10' x 15' 10' x 15' 10' x 15' ' 20 x 15
I ? 14'-3"
I
BUILDING A UNIT MIX
FINISH SCHEDULE
Roll—up Doors
Roof (storage)
Roof (office / apartment)
Perimeter Panel
Trim
Downspouts
Piers & Headers
* Color Selections must be on File prior to Releasing for Fabrication
SHEET INDEX
C-1
7S-0
COVER SHEET
GENERAL
NOTES
S-1
BUILDING
# 1
— UNIT MIX & FRAMING PLAN
S-2
BUILDING
# 2
— ELEVATIONS & SECTION
S-3
DETAILS
S-4
DETAILS
S-5
DETAILS
S-6
DETAILS
S-7
DETAILS
S-8
DETAILS
BUILDING A UNIT MIX
FINISH SCHEDULE
Roll—up Doors
Roof (storage)
Roof (office / apartment)
Perimeter Panel
Trim
Downspouts
Piers & Headers
* Color Selections must be on File prior to Releasing for Fabrication
r
General Notes
1. These plans and the information contained herein are the property of
The Rabco Corporation unauthorized uses are prohibited.
2. Owner / Contractor is responsible to provide The Rabco Corporation with
approved plans prior to fabrication.
3. Owner/Contractor is responsible for all necessary permits, fees, deposits, ect.
4. The owner and/or contractor shall review and determine that all dimensions
are coordinated as required with all other design professionals drawings for
project prior to fabrication of materials or start of construction. Any
discrepancies shall be reported to The Rabco Corporation.
5. The sheetledges, rainlips and masonry ledges are vital to the proper fit of the
steel construction. Owner/Contractor shall field verify all to be as shown on
plans. If they are not to the drawings contact The Rabco Corporation
before steel erection starts.
6. Any omissions and/or conflicits with plans shall be reported to
The Rabco Corporation so that they can be resolved prior to proceeding.
7. Do Not Scale Drawings - if a dim. is req. contact The Rabco Corporation.
8. No modifications to plans shall be made without the permission of
The Rabco Corporation. Modifications required due to field conditions
or other contractors or items that which may adversely affect the structure
requires written permission (no modifications to str. members is allowed).
9. All sections and details shall be considered to be typical or similar unless
another section or detail is referenced on the plans.
10. Scope of Work of The Rabco Corporation is indicated in the contract.
The drawings reflect scopes of work as required for permitting or at the
direction of Owner/Contractor.
11. Elevator and Stairwell Shop Drawing are critical to ensure the dimensions
and design outlined in these plans meet the minimum requirements
required by this scope of work if under contract by others. In the event the
contractor's or owner's failing to provide, he shall be responsible for the
results or any such errors or omissions and the cost of rectifying the same.
12. The Rabco Corporation does not provide a rated ceiling in shaft enclosures
unless specificated noted on plans.
1.3. Construction documents were designed and meet the requirements of the
of the local building code designated under structural design criteria.
14. All components and cladding furnished by others not incorporated in these
construction documents are required to meet the requirements of the
and furnish shop drawings to governing
authorities as required.
15. These loads are not applicable on self storage buildings where -the primary
roof drainage is accomplished by gutters and downspouts. Secondary
drainage occurs with gutter overflow which is at or below eave ht. of bldg(s).
Structural Notes
General
1. Temporary bracing should be provided to resist wind loading on structural
components and structural assemblies during erection and construction phase.
2. Scopes of work by others whose lateral loads will be transferred into steel
member provided byThe Rabco Corporation shall be temporary braced by
others in a method, that does not interfere with erection of steel, until steel
erection complete.
3. The uncoated minimum steel thickness of the cold -formed products as
delivered shall not be less than 95% percent of the design thickness.
Thickness measurements may be made anywhere across the width of the
sheet, but not closer to the edges than the minimum distances specified in thr,-
relevant ASTM specifications. Thickness at bends, such as corners, may be
less than 95 percent of design thickness, due to cold -forming effects, and still
be acceptable.
4. Recessed entries and breeze ways need to be recessed below finished
floor to avoid potential water problems, roll up located in breeze way need to
be installed in recessed area. If a change is made by Owner/Contractor
please notify The Rabco Corporation as soon as possible.
5. All erection, fabrication, workmanship and installation shall be in accordance
with installation procedures manual and / or industry standards approved
by The Rabco Corporation and the Engineer of Record.
Roof Systems: MSCI or Equal_
1. Roofing shall be installed per manufacturer's recommendations and
specs, along with The Rabco Corporation install. procedures manual.
2. Roof Sheets should be installed from the lowest step-down to highest elevation.
1.
2,
3.
4.
1.
2.
3
4.
Insulation: Bay Insualtion Supply Co. or Equal
Vinly Backed Insulation
R -Values for winter conditions (mean 40 degrees F): .6 Ib Density Fiberglass
3.0" = 10, .6 Ib Density Fiberglass 3.5" = "11, .6 Ib Density Fiberglass 4.0"
= 13, .6 Ib Density Fiberglass 6.0" = 19.
Poly Single Bubble Foil Fire Rated R -Foil by TVM
R -Values for Roof = 10
Foil Double Bubble Foil R -Foil by TVM
R -Values for Roof = 10
Insulation shall be installed per the manufacturer's published instructions.
Insulation may be installed in one or multiply layers to meet the req. R -Value
Cold Formed Steel: L.GSI _Sections or Equal
Cold Form Steel Sections shall conform to Applicable Provisions of
ASTM A572, ASTM A607 and/or ASTM A611.
Min. Deliveried Thickness of Cold Formed Steel Cee's & Zee's
(`n 11n4inn ThirknnRn FIn14h
12
0.1050
Red -Oxide ONO on Plans
14
10.0700
Red-Oxlde ONO on Plans
16
0.0590
Red -Oxide UNO on Plans
18
0.0468
Galvanized
20
0.0352
Galvanized
Min. Deliveried Thickness of Cold Formed Steel Piers & Headers
(_nnc nQ-zinn ThirknpaM Fink:h
14
0.0700
Tex -Cote Finish
applied in Field
16
0.0590
Tex -Cote Finish
applied in Field
16
0.0550
Pre -Finished
3,000
18
0.0468
Tex -Cote Finish
applied in Field
Notes
a. Inside return on piers is 3 1/2" to 4", verify required dimensions
for exterior roll up doors.
Load Bearing Stud to Track Connections: The ends of the load bearing
studs must be installed into the top and bottom tracks so that the gap between
the ends of the stud and the web of the track is as small as practicable and in
no case greater than 3/16" at the time of installation. The gap must be less
than 1/16" after the dead load of the structure is in place.
Bolted Connections
1. Bolts not called out are to be ASTM A325 -X with a shear strength of 30 KSI.
2. The appropriate method for bolted connections used is the "turn of the nut"
for tightening the bolts shown in the sections reflected in plans UNO.
Concrete / Masonry Anchors or Fasteners: Hilti or Eaual
1. Anchors
shall be installed and torqued
per manufacturer's specifications.
2. Allowable capacities for concrete masonry
units shall conform to ASTM C90
with 2000 psi grout - ASTM C476.
3,000
4" +
3. Material
Specification
Slabs -on -Grade <=4" thick)
3,000
a.
Bolts and Studs
ASTM
A307
b.
Carbon Steel Nuts
ASTM
A563
c.
Carbon Steel Washers
ASTM
F436
d.
Carbon Steel Threaded Rods
ASTM
A36
e.
Wedge Anchors
ASTM
A510/A108
f.
Zinc Plating
ASTM
B633
Welded Connections
1. All structural steel welding shall conform to American Welding Society
Standard D1.1, latest edition.
2. All str. steel welding electrodes shall conform to AWS A5.1 or A5.5 E-70XX.
3. Paint all welds with rust inhibitive paint.
Concrete Requirements from Buildina Component
Location
Notes
28D(psi)
Slump
18 0.0474 Galvanized
Max Agg
Foundations
3,000
4" +
- 1"
1 1/2*
Slabs -on -Grade <=4" thick)
3,000
4" +
- 1"
1 1/2 -
2"Slabs-on-Grade
Slabs -on -Grade 4"+ thick
4,000
4" +
- 1"
1 1/2 -
2"Tie
Tie Beams
4,000
4" + L7
1"
3/4"
Tie Columns
3,000
4" +
- 1"
3Z4 -
4"Cast-in-Place
Cast -in -Place Beams
4,000
4" +/- 1"
1"
Cast -in -Place Columns
4,000
4"+
p
- 1
1"
Elev. Slabs mtl deck
3,000f
4"
-19.76
-18.96
Filled Cell Grout ASTM L4761
2,500
8" to
'11"
8"
3/8 -
Notes
a. The above requirements are general and do not supersede
notes or details in the plans.
b. Minimum Flexural Strength = 550 psi
c. Slump for Ramps and Sloping Surfaces shall not exceed 4"
d. Cold Joints is not Recommended - Although if Contractor requires
cold jts. they should be a min. of 2' - 0" off centerline of columns.
e. If lateral load from retaining walls or stern walls are being transfed
through building do not backfill until elevated slab(s) are poured
and the concrete has achieved design strength.
f. Slabs < 5" - reinforced with 6 x 6 W1.4 x W1.4 & Slabs > 5" -
reinforced with 6 x 6 W2.1 x W2.1
Metal Floor Deck: Vulcraft or Equal
1. Deck shall conform to the Steel Deck Institue - Design Manual for Composite
and Non -Composite Decks, Form Decks and Roof Decks, latest edition.
2. The requierments of the lastest adopted edition of the AISI section A3 shall
govern fabrication of the specified steel deck.
3. All field welding of floor deck shall be in strict conformance with ANSI /
AWSD1.3 Structural Welding Code.
4. The minimum yield strength of steel used shall be 33 ksi.
5. Galvanizing shall conform to ASTM A653-94 structural quality and federal
spec QQ-S-775.
6. Min. Deliveried Thickness of Metal Floor Deck
Gnnn neginn Thickness Finish
7. Composite steel floor deck shall be attached to the supporting structure as
recommended by the manufacture with maximum spacing not to exceed
18" O.C. Typical pattern of 36/4 using the following fasteners UNO on plans.
n
11
Sldelap's
16 0.0598 Galvanized
Building
18 0.0474 Galvanized
20 0.0358 Galvanized
22 0.0295 Galvanized
7. Composite steel floor deck shall be attached to the supporting structure as
recommended by the manufacture with maximum spacing not to exceed
18" O.C. Typical pattern of 36/4 using the following fasteners UNO on plans.
n
11
Sldelap's
#12 Hex Head Screws
Building
for quantity ands acing see lana
Cold Formed Steel
#14 Hex Head Screws
Structural Steel => 1/8"
#14 Hex Head Screws or
Load Combinations:
0.145 Min. Dia. PAF
Ends of metal deck shall bear a minimum of 2 - 1/2" on supporting members
UNO on plans. Ends of metal deck shall either be lapped or abutt and shall
have a minimum of 1" end distance from center of fastener.
Pentrations through floor slab are not permitted without written approval by
the Engineer of Record.
Site Requirement Notes
1. The Rabco Corporation requires site to be stabilized and maintained during
heavy percipitation.
2. Owner / Contractor to provide material storage area on site other than
building being erected.
3. A construction dumpster unit must be provided on the jobsite at no cost to
The Rabco Corporation.
4. Temporary power shall be provided to allow for a mazimum power lead run
of 200 feet to each structure being erected.
5. Temporary power must meet all applicable codes and safety requirements.
6. Building pads will be broom clean and free of debris prior to
The Rabco Corporation crew beginning installation sequence as agreed.
7. Access to the site and all sides of building with equipment and free from any
encumbrances to delivery or erect.
8. Cleaning of materials, including but not limited to, wall panels and structural
materials, is not responsibility ofThe Rabco Corporation.
9. The contractor shall properly protect the work for public safety and against
accidents, weather or any other hazards with lights, guardrails or barricades
as applicable (includes fall protection on multi -story buildings).
Structural Desib►n Cri t o rz a
Codes and ReAerences
Building Code:
2004 Florida
Building
Code
Reference Standard:
ASCE 7-02
Least Hor. Dim.
(ft.):
Load Combinations:
Per ASCE7
(ft.):
17.50
Design Manuals:
AISC Manual
of Steel
Construction
(ft.):
Allow Stress
Design
- 9th Edition
0.00
AISI Specification for
the Design of
6,650.00
Cold Formed
Steel Structural
Members 1996
Str. Members Design:
Allowable Stress
Design (ASD)
10
(also called
working
stress design)
Wind Load 1De��jgn Parameters
Wind Vel. -3 Sec. Gust(V-mph) = 120
Location Description = Hurricane Regions(V>100mph)
Procedure = Analytical - Method 2
Components and Cladding
Method = Low -Rise Buildinq & Buildings - h <= 60 ft.
D'Y. rl, n" -1 C I n fn I a- n a
A s a1j %1u v
Claas2 2eat2on
I✓ 6/ 9 w v 4l vv 9 V v
No. I A
Const. Type =
Occupancy Group (primary) =
Occ. (secondary if mixed) =
Stories =
Spkler Sys(per NFPA13) =
Loadzn�
Effective Weight (kips):
Design Base Shear (kips):
Roof Dead Load (psf):
Roof Live Load (psf):
Floor LL - Lt. Storage (psf):
Floor LL -- Corridors (psf):
Colateral Loads Storage (psf):
Colateral Loads Hallways (psf):
Edge Condition - a (ft.):
T e IIB -Un
Group S-1
N/A
1 - Story
No
66.50
6.26
Self Weight
20.00
N/A
N A
2.00
2.00
3.30
Deseriptzon
Bldg Enclosure Classification
= Enclosed
Roof Pitch Rise (in./ft.):
= 8.25
0.25
Least Hor. Dim.
(ft.):
35.00
Distance to Ridge
(ft.):
17.50
Width
(ft.):
35.00
Length
(ft.):
190.00
Adjustment
(sf):
0.00
Building Sq. Ftg.
(sf):
6,650.00
Mean
Roof:
8' - 3"
Wind Loads
I O -al Jq. t -Cq. = b,b7U.UU
Nature of Occupnacy: I -Bldg or Str represents Low Hazard to Human Life
Category: I
Wind Roof Type = Gable Roof <= 7' or Monoslope Roofs <= 3'
Assumed Exposure B
Bldg Enclosure Classification
= Enclosed
Mean Roof Height
= 8.25
Numerical Coefficient
= 0.00256
Wind Load Imp. Factor (1)
= 0.77
Vel. Pres. Exp. Ceoff. (Kh)
= 0.70
Topographic Factor (Kzt)
= 1.00 (Assumed No Topo Factors)
Wind Directional Factor (Kd)
= 0.85
Velocity Pressure (qh)
= 16.89
Int. Pressure Coeff. (GCpi)
= 0.18 -0.18
Design Wind Pressures
= qh x (GCp - GCpi)
Component and Cladding
Pressures
Effective Areas (sf)
Roof Pressures
1, 2 & 3 Positive
1 Negative
2 Negative
3 Negative
Watt Pressures
4 & 5 Positive
4 Negative
5 Negative
10
20
50
100
200
500
10.00
10.00
10.00
10.00
-19.93
-19.43
-18.75
-18.24
-33.44
-29.91
-25.20
-21.62
-50.33
-41.75
-30.31
-21.62
10
20
50
100
200
500
18.24
17.45
16.36
15.56
14.75
13.68
-19.76
-18.96
-17.88
-17.08
-16.28
-15.20
-24.32
-22.72
-20.53
-18.96
-17.38
-15.20
171'-6"
n /n /7" .. 1 1 1 /A"
LINE KEY
HORIZONTAL PARTITION PANEI
29ga GALVALUME TYPE "U"
COLUMNS
FIRE WALL
9 26ga VERTICAL PERIMETER PANEL (EXTERIOR) I
CORNER PIER, HEADER, PIER
— ZEE BEAMS
COLUMNS
STRUCTURAL NOTES
COLUMN
4016 — 4"
X 2
1/2" X
16ga GEE
PURI_IN
: 4Z16 — 4"
X 2
1/2" X
16ga ZEE
ONE HOUR RATED WALL U(: #U425
4" X 20ga
STUDS 0 2' O.C.
MIN.
BY METAL
BUILDING COMPANY &
(1) LAYER
5/8" GYP. BOARD
EACH
SIDE BY OTHERS
EDGE/2„
1 1/2- x 2 1 /2" 1 1/2" x 2 1/2"
SHEETLED
SHEETLEDGE
1 1/2" x 1161 /4
RAINLIP
1 1/2" x 2 1/2"
SHEETLED
.0
BUILDING A UNIT MI/A
1/2" x 11 1 /4"
RAINLIP
1 1/2" x 2 1/2"
SHEETLF_DGE
1/2"
HEETLEDGE
FRONT
*)UILDING A FRAMING PLAN
RAKE TRIM
T/EAVE
81-311
FROM R.L. 1
RAKE TRI
T/EAVE
8'
FROM R.L.
GUTTER EXP. BOX i
GUTTER 1
GUTTER EXP. BOX i
DOWNSPOUTS 30' O.C. MAXI
a„>•LLIr..O.
1}�„a„�„- uyi_„
� .....,amu,-.. �LLl.O.Ifl.1�.11�.1.�I1L�1,l
r.,l��„rl,lr.p.�ll �.Lll�lll�l.I�ll�ll._,l,LLr”,1.�1,1�1,_�,.�,.111."Il!•all.!•�.11rl„
:. ,.,
':
-
WA -1
I
'. •
�.
\ � • �
11111 I,A»1,,}}1,.,}}pY ,1,111
M 1 1 IY 1 I"1
�wrY
.:
� ��• 1�w
'
,
W
r
.►ars r �I. yrrl�r
rl
.�,�.��
IE
BUILDING BACK ELEVATION
TYPICAL PIER AND HEADER TEX COTE PAINTED
(FIELD APPLIED UNLESS INDICATED OTHERWISE)
PIER - 18" X 16ga
CORNER PIER - 9" X 9" X 16ga
SIDE WALL HEADER - 15" X 18ga
24ga STANDING SEAM ROOF "ULTRA-DEK" (GALVALUME)
DOWNSPOUTS 30' Q.C. MAX.
0 GUTTER EXP. BOX 90' O.C. MAX.
(AIAKE TRIM
T/EAVE
8-31,
FROM R.L.
9'-3" —" I fes-- 8'-611 --I I-� 8'-6" �I fes- 8'-6" —�-I h�— 8'-6" 8'-6" 8'-6" ---1 fes- 8'-6" 8'-6" 8'-6" 8'-6" 81-6" 8'-6" 8'-6" �� I� 8'-6" -�� f� 8'-6" —m) I 8'-6" �I I� 8'-6" �1 I� 8'-6" �1
190' -
BUILDING FRONT ELEVATION
GUTTER AND DOWNSPOUT 20'
T/RIDGE
d
FROM R.L.
RAKE TRIM GUTTER AND DOWNSPOUT
GUTTER AND DOWNSPOUT —
T/RIDGE T/EAVE
15" X 18ga HEADER -
18" X 169a PIER I -�
T/E AVE
"
FROM R.L.
5'
8'-2j"
5'
8' —4"
LO'
8,-%"
5'
GUTTER AND DOWNSPOUT -
T/EAVE F
8'-3"
5'
FROM R.L.
20'
UTTER AND DOWNSPOUT
T/EAVE T/RIDGE
�” 8,-811
RIDGE CAP
2 g VERTICAL
-•—
35'
-24ga STANDING SEAM ROOF
"UL TRA-DEK" (GA1_VAL UME)
" VINYL BACKED INSULATION IN ROOF
/—'4" X 2 1/2" X 16ga ZEE BEAM
8,-64" 8,_4" 8,-3j"
5' 5' 1 5'
4
GUTTER AND DOWNSPOUT
T/EAVE
15" X 18ga HEADER
8-31,
- I 18" X 16ga PIER
FROM R.L.
' I I I I FROM R.L.
4" X 2 1/2" X 16ga FOUNDATION AND FOOTING
1 1/2" X 11 1/4" CEE COLUMN TYP. BY OTHERS — 1 1/2" X 11 1/4"
RAINLIP RAINLIP
35' - --
SECTION A -A
R.L.
TRIM
T/E4VE
T
-311
! FROM R.L.
WA -1
GUTTER AND DOWNSPOUT —
T/RIDGE T/EAVE
15" X 18ga HEADER -
18" X 169a PIER I -�
T/E AVE
"
FROM R.L.
5'
8'-2j"
5'
8' —4"
LO'
8,-%"
5'
GUTTER AND DOWNSPOUT -
T/EAVE F
8'-3"
5'
FROM R.L.
20'
UTTER AND DOWNSPOUT
T/EAVE T/RIDGE
�” 8,-811
RIDGE CAP
2 g VERTICAL
-•—
35'
-24ga STANDING SEAM ROOF
"UL TRA-DEK" (GA1_VAL UME)
" VINYL BACKED INSULATION IN ROOF
/—'4" X 2 1/2" X 16ga ZEE BEAM
8,-64" 8,_4" 8,-3j"
5' 5' 1 5'
4
GUTTER AND DOWNSPOUT
T/EAVE
15" X 18ga HEADER
8-31,
- I 18" X 16ga PIER
FROM R.L.
' I I I I FROM R.L.
4" X 2 1/2" X 16ga FOUNDATION AND FOOTING
1 1/2" X 11 1/4" CEE COLUMN TYP. BY OTHERS — 1 1/2" X 11 1/4"
RAINLIP RAINLIP
35' - --
SECTION A -A
R.L.
TRIM
T/E4VE
T
-311
! FROM R.L.
BEND END OF ROOF PANELS DOWN USING
TOOL PROVIDED BY THE METAL BUILDING COMPANY
SEE ENLARGED VIEW BELOW
GUTTER STRAP
AT 4' O.C.(SUNBELT) 3"
AT 2' O.C.(SNOWBELT)
owl=
14x 7/8" ULTIMATE LAP TEK -
W/ SEALING WASHER
FASTENER # TX4
GUTTER
TRI BEAD TAPE SEALER -- --�
140/8" LAP TEK ULT.
W/ SEALING WASHER AT 12" O.C. +
(CONT. TRI BEAD SEALANT +
BETWEEN GUTTER AND U-DEK) v
18ga OR 16ga HEADER —
(15" HEADER SHOWN)
1 4-14X 1" TEK 3 WHEN HEADER
IS OVER 18"—�^-
FASTENER #T1 B
BEND DOWN.
ROOF SHEET
WITH TOOL
GUTTER
(2) 1/2-x3-3/4'
WEDGE ANCHOR AT EA. PIER
FASTENER #WA.5-3.75
FOLLOW INSTALLATION PROCEDURES
AS LISTED IN ROOF SECTION.
METAL INSIDE CLOSURE
- 1/4-14 x 1 1/4" ULTIMATE LAP TEK
FASTENER #TX3
TRI BEAD TAPE SEALER
FULL LENGTH OF EAVE OVER
AND UNDER I/S CLOSURE
1/4"-14x1" TEK
(2 PER INSID CLOSURE)
FASTENER T1 B
ROOF INSULATION
PEV �ONTRACT I
. RETAINER ANGLE
/ (1) 1 /2"DIAx 1 " BOLTS
— (PIER TOP PLATE) #8.5-1
FLAT WASHER
INSIDE OF PIER ONLY
(3) 1 /2"DIAx 1- BOLTS
BOLTS AT HEADER TO PIER
FLAT WASHER BOTH
SIDES OF CONNECTION
#8.5-1
Ah\In111T 1 IDLES
1/4"-14 X 1 1/4" ULTIMATE TEK
#TX3 FASTENER
W/ SEALING WASHER
(8 PER ENDLAP
TRI BEAD SEALANT
OVER KNIFE EDGE
3" STANDING
SEAM ROOF PANELS
i ULTRA DEK®
i BACKUP PLATE
►�-- TRI BEAD TAPE SEALER
LOCATED OVER PRE PUNCHED HOLES
�-- ROOF CLIP
1/4"-14x1" TEK FASTENER #T1B
ZEE BEAM (AS RQD. SEE PLAN)
3" STANDING SEAM ROOF PANELS
GAUGE AND COLOR AS SPECIFIED
IN CONTRACT
NOTE: APPLY TRI BEAD TAPE SEALANT
OVER KNIFE EDGE OF MALE SEAM OF
U—DEK PRIOR TO ASSEMBLING OF
iNDATION U—DEK WITH FEMALE PORTION OF SEAM
FRS
'
f:)ROOF .LOW .FIDE FAVF, PIER & HEADER
S-3)
TRI BEAD TAPE SEALER
OVER AND UNDER
METAL INSIDE CLOSURE
FASTENER #TX4
FASTFNFR JITX4--.
18ga OR 16ga HEADER
(15" HEADER SHOWN)
U DEK TO HEADER FASTENER #TX3
FASTENER #T1 B
/—FASTENER #TX3
ROOT' .LOW SIDE SAVE, PIER & HEADER
STANDING SEAM ROOF
ULTRA DEKO
ROOF INS. PER CONTRACT
RETAINER ANGLE
APPLY DOUBL EFACE
TAPE OVER CLOSED HEM AREA OF
RETAINER ANGLE WHEN
INSULATION IS USED.
(1) 1/2"DIAX 1" BOLTS #B.5-1
FPIER TOP PLATE)
LAT WASHER
INSIDE OF PIER ONLY
—(3) 1/2"DIAx 1" BOLTS #B.5-1
BOLTS AT HEADER TO PIER
FLAT WASHER BOTH
PIER SIDES OF CONNECTION
TRI BEAD TAPE SEALER
SEE ENLARGED VIEW BELOW --
RAKE SUPPORT
RAKE TRIM ----� /
14x 7/8" ULTIMATE LAP TEK
W/ASTNRWXE
FASTENER 14
18ga OR 16ga HEADER —�
(15" HEADER SHOWN)
7/8"
1/4"-14X1 TEK WHEN HEADER
IS OVER 1 "
FASTENER T1 B
ATTACH HEADER TO PIER WITH 6
1/4"-14 X 1 TEK WERE BOLT HOLES
DO NOT ALIGN _
FASTENER #T1 B
(2) 1/2"x3-3/
WEDGE ANCHOR AT EA. F
FASTENER #WA.5-3.
-3
0
FASTENER #TX4
X(,1/4-14X 1 1/4" UL TIMATE TEK AT 2'-0" O.C.
W/ SEALING WASHER
FASTENER # TX3
) 1/2"DIAx 1" BOLTS #B.5--1
(PIER TOP PLATE) 3" STANDING
SEAM ROOF PANELS
ULTRA DEK'@
J ZEE BEAM PER PLAN
I
� I i
��1/4"— 14X1" TEK FASTENER #T1B THROUGH EAVE CHANNEL INTO ZEE
BEAM WHEN INSTALLING RAKE SUPPORT LOCATE SCREWS IN CENTER
OF SLOTTED HOLE IN RAKE ANGLE (2'-6" O.C.)
AT MID SPAN BETWEEN ZEE BEAMS
VFASTENER #T5
a CHANNEL ATTACHED TO EACH PIER
H 4-1/4 X 14 X 1 TEK FASTENER #T1 B AND
DER FLANGE WERE APPLICABLE 24" O.C.
(3) 1/2"DIAx 1" BOLTS #8.5-1
BOLTS AT HEADER TO PIER
CONDUIT HOLES
JNDATION
E_ND WATT - RAKE, PIER & HEADER
14x 7/8" ULTIMATE LAP TEK—
W/ SEALING W�SHER
FASTENER TX4 7
18a OR 16ga HEADER
115" HEADER SHOWN)
TRI BEAD TAPE SEALER
Ill
FASTENER TX4
1 X 1 ANGLE
ER TX3
1 /4"-14x 1-1 /4"TEK
FASTENER #T5 3" STANDING
SEAM ROOF PANELS
ULTRA DEKA
14ga CHANNEL ATTACHED TO EACH PIER ZEE BEAM PER PLAN
WITH 4-1/4 X 14 X 1 TEK FASTENER #T1 B AND
HEADER FLANGE WERE APPLICABLE 24" O.C.
(1) 1 /2"DIAx 1 " BOLTS #13.5-1
FR TOP LATWASHER
�TE)
INSIDE OF PIR ONLY
\—(3) 1 /2"DIAx 1- BOLTS #.5-1
-- BOLTS AT HEADER TO PIER
FLAT WASHER BOTH
PIER SIDES OF CONNECTION
END WALL RAKE, PIER & HEADER
BEND END OF ROOF PANELS DOWN USING
TOOL PROVIDED BY METAL BUILDING COMPANY
SEE ENLARGED VIEW BELOW
GUTTER STRAP_\�t
AT 4' O.C.(SUNBELT) 3"
AT 2' O.C.(SNOWBELT)
14x 7/8" ULTIMATE LAP TEK
W/ SEALING WASHER
FASTENER # TX4
GUTTER �11'
METAL INSIDE�\ / j
CLOSURE
14x7/8" LAP TEK ULT.
W/ SEALING WASHER AT 12" O.C.
FASTENER #TX4
(CONT. TRI BEAD SEALANT
BETWEEN GUTTER AND U-DEK)
2 X 4 TRIM ON WALL PANEL
7
(INSTALL PRIOR TO INSIDE CLOSURES)
CEE COLUMN AT 10' O.C. AT SIDEWALLS
EXTERIOR VERTICAL PANELING
SCREW TO TOP TRACK , ZEE GIRT, AND BOTTOM
TRACK W/ 12 x 1 S.D.S. FASTENER #T17 AT 12" O.C.
SIDE LAPS TO BE SCREWED 20" O.C.
W/14 x 7/8 LAP TEKS
FASTENER #T4A
4"x2 -1/2"X16 GA. INSET ZEE GIRT
4'-6"
BASE TRIM- IRS10
END LAPS- FOLLOW INSTALLATION PROCEDURES
AS LISTED IN ROOF SECTION.
1/4-14x 1 1/4- ULTIMATE TEK
FASTENER #TX3
1/4 -14X 1 1/4- ULTIMATE #TX3 I
TRI BAD TAPE SEALER W/ SEALING WASHER
FULL LENGTH OF EAVE OVER (8 PER ENDLAP)
AND UNDER I/S CLOSURE f TRI BEAD SEALANT
FASTENER #T1 B OVER KNIFE EDGE
FASTENER 3" STANDING
ROOF INSULATION SEAM ROOF -PANELS
I — 7 �� ULTRA DEK
�� /-BACKUP PLATE
�— TRI BEAD TAPE SEALER
1 (LOCATED OVER PRE PUNCHED HOLES)
RETAINER ANGLE ROOF CLIP
4x2x14 GA. TOP TRACK 1 4"-14x1" TEK T1B
(1) FASTENER #T1A / #
Pd
SIDE
ZEE BEAM (AS RQD. SEE PLAN)
STANDING SEAM ROOF PANELS
— W�xGX CLIP ANGLE
(441 #12 TEKS INTO CEE
COLUMN AND (2) INTO GIRT FASTENER #T1A
1 /2"DIA. 3 3/4" LOK/BOLT WEDGE ANCHOR
3' O.C. INSTALLED W/ MIN. EMBEDMENT
OF 3" INTO CONCRETE SLAB.
FASTENER # WA .5-3.75
4" X 2" X 16ga GALV. BOTTOM TRACK
ANCHOR CEE COLUMN TO
TRACK W/ (1) 12x 3/4" TEK
(1) FASTENER #T1A
PER SIDE
NOTE: APPLY TRI BEAD TAPE SEALANT
OVER KNIFE EDGE OF MALE SEAM OF
U—DEK PRIOR TO ASSEMBLING OF
U—DEK WITH FEMALE PORTION OF SEAM
1 X 1 ANGLE
TRI BEAD
TAPE SEALER
SEE ENLARGED VIEW BELOW
RAKE SUPPORT
FASTENER #T17
RAKE TRIM
r
I
14x7/8 LAP TEK
W/ SEALING WASHER
FASTENER # T4A
1
26ga VERTICAL PANEL
SCREW TO TOP TRACK , ZEE GIRT, AND BOTTOM'
FASTENER T#17 AT 12" O.C.
SIDE LAPS TO BE SCREWED 20" O.C.
W/14 x 7/8 LAP TEKS
FASTENER #T4A
4" x 2-1/2" x 16 GA. INSET ZEO GIRT
4'-6"
4" X 2" X 16ga GAL V. BOTTOM TRACK -
BASE TRIM-RS101
-- FASTENER #TX4
/-- 1/4 W/ SEALING WASHERS TEK FASTENER #TX3
1/4"-14x1-1/4"
SHOULDER TEK FASTENER #T5
AT PURLIN 3" STANDING
FSEAM
ROOF--PANELS
\\ ULTRA DEK
I I I
I I �
I I ZEE BEAM PER PLANS
I �I (1) 1/2"DIAx 1" BOLTS
I I FASTENER # B.5-1
I I
I I
I I
I I
I I GEE COLUMN AT 5' O.C. AT ENDWALLS
I I
I 'I
IL 4x4x12 GA. CLIP ANGLE
I I W/ 4 #12 TEKS INTO CEE
COLUMN AND (2) INTO GIRT #T1A
1/2 -DIA. 3 3/4" L.OK/BOLT WEDGE ANCHOR
3' O.C. INSTALLED W/ MIN. EMBEDMENT
OF 3" INTO CONCRETE SLAB.
I FASTENER # WA .5-3.75
I ANCHOR CEE COLUMN TO
I TRACK W/ (1) 12x 3/4" TEK
(1) FASTENER #T1A
PER SIDE
ROOF LOW SIDE EAVE, PANELED WALL _ 2 END WALL W/ GOOF PANEL, ON MODULE
S--4 VERTICAL WALL PANEL S-4 VERTICAL WALL PANEL
GUTTER
STRAP
END OF ROOF PANEL
BEND DOWN USING
BEND DOWN TOOL
TRI BEAD TAPE SEALER -
OVER AND UNDER
METAL INSIDE CLOSURE
FASTENER #TX4
FASTENER
L
TRI BEAD TAPE SEALER
FASTENER #TX4
FASTENER #T1A ---
2 X 4 ANGLE
NOTE: -MUST BE INSTALLED PRIOR)
TO METAL INSIDE CLOSURES.
2X4 ANGLE IS CRITICAL TO
CREATE A WEATHER TIGHT SEAL
AT THE EAVE.
VERTICAL WALL SHEETS
U DEK TO HEADER FASTENER #TX3
INSIDE METAL CLOSURE
FASTENER #Ti B
/—FASTENER #T12
4X2X14ga
TOP TRACK
FASTENER #T1A
ROOF AT LOW SIDE EAVE, PANEL FD WALL
STANDING SEAM ROOF
ULTRA DEK@
— ROOF INSULATION
RETAINER ANGLE
APPLY DOUBLEFACE
TAPE OVER CLOSED HEM AREA OF
RETAINER ANGLE WHEN
INSULATION IS USED.
CEE COLUMN PER PLAN
TRI BEAD TAPE SEALER
FASTENER #T17
RAKE TRIM
FASTEN ER
VERTICAL WALL SHEETS
FASTENER #TX4
1 X 1 ANGLE
-- FASTENER #TX3
REVISIONS
END WALL W/ ROOF PANEL, ON MODULE
VERTICAL WALL PANEL
1/4"-14x1-1/4" SHOULDER TEK
FASTENER #T5
RAKE SUPPORT STANDING SEA ROOF
ULTRA DEKW
ZEE BEAM PER PLAN
(1) 1/2" DIA X 1" BOLTS
FASTENER #13.5-1
SINGLE STORY COLUMN AND BEAM CONNECTIONS
CL STRUCTURAL DIM. LINE
STRUCTURAL DIM, LINE
[— CL STRUCTURAL DIM. LINE
7-1/2" SHORT LAP
I
NOTE:
TOP FLANGE OF ZEE STANDS 1" TALLER
11-1 2" SHORT LAP
/
�
[—STEEL LINE
THAN TOP OF CEE COLUMN.
II
11-1/2- SHORT LAT
P
BUILDING WIDTH OR LENGTH DIMENSION
PIER FACE
4"x2-1 /2"x16 GA.
ZEE BEAM
(2) 1 /2"DIA. x 1"
A307 BOLTS -TYP.
FASTENER #B.5-1
4"x2-1 /2"x16
ZEE BEAM
GA.
I
(4) 1 /2"DIA. x 1" NOTE:
TOP FLANGE OF ZEE STANDS 1" TALLER
A307 BOLTS -TYP. THAN TOP OF CEE COLUMN.
FASTENER #B.5-1
1" SET BACK (IF FOUNDATION ALLOWS}- --
11.25" RAINLIP
(2) 1/2"x3-3/4"
1 1/2- WEDGE ANCHOR AT EA. PIER
FASTENER #WA.5-3.75_
- ----------------
I
1 /2"DIA. 3 3/4" LOK/BOLT WEDDGE ANCHOR
6 ga GALV. CENTERLINE OF COLUMN
CEE COLUMN
L
12 GA. BASE ANGLE
ATTACH TO COLUMN W/
1/2 0 X 1 A307 BOLT (1) 1/2"x3—WEDGE ANCHORS OR EQUAL
FASTENER #B.5-1 �\ / MINIMUM EMBEDMENT=3
FASTENER #WA.5-3.75
6"x2-1/2"x16 GA.
CEE COLUMN
12 GA. BASE ANGLE
ATTACH TO COLUMN W
(2)1/2-0 X 1 A307 BOLT
FASTENER #B.5-1
CENTERLINE OF COLUMN
(2) 1/2"x3-3/4' WEDGE ANCHORS OR EQUAL
MINIMUM EMBEDMENT=3
FASTENER #WA.5-3.75
� \N�\��\�
\
\ \ \ \ \
\ j��\\\
�j ' // ' // ' // �j SLAB ANDFOUNDATION
BY RS
-- SLAB AND FOUNDATION 4" MIN.
SLAB AND FOUNDATION 4" MIN,
NOTE:
(6) 1 /2"DIA. x 1 " TOP FLANGE OF ZEE STANDS 1 " TALLER
I I
OF 3" INTO CONCRETE SLAB.
FASTENER # WA
NOTE:
VIEW PERPENDICULAR
TO LENGTH OLJjUJLUM
A307 BOLTS -TYP. THAN TOP OF CEE COLUMN.
VIEW PEI3PEUDICULM
TO
LENGTH OF BUILDING
VERIFY SLAB WIDTH AND LENGTH BEFORE
SETTING PIERS IN 1"
NOTE: GAUGES
MAY CHANGE DUE TO
LOAD CONDITIONS
ZEE BEAM
ZEE BEAM COLUMN
CONNECTION
FOR 8", 10" & 12"
(,Z ZEE
BEAM COLUMN
CONNECTION
4" X 2" X 16 � GALV. BOTTOM TRACK
9
MER TO FOUNDATION DETAIL
4" CEE COLUMN &6"
4" ZEE BEAM
'S—JrCEE COLUMN &
4" ZEE BEAM
VERTICAL PANEL SHOWN
STRUCTURAL DIM. LINE
CL STRUCTURAL
STRUCTURAL DIM, LINE
[—STEEL LINE
7-1/2" SHORT LAPI
II
11-1/2- SHORT LAT
P
- ----------------
I
1 /2"DIA. 3 3/4" LOK/BOLT WEDDGE ANCHOR
3' O.C. INSTAI I ED W/ MIN. EMBEDMENT
(4) 1/2"DA. x 1"
NOTE:
(6) 1 /2"DIA. x 1 " TOP FLANGE OF ZEE STANDS 1 " TALLER
I I
OF 3" INTO CONCRETE SLAB.
FASTENER # WA
A307 BOLTS -TYP. NOTE:
FASTENER #B,5-1 TOP FLANGE OF ZEE STANDS 1" TALLER
A307 BOLTS -TYP. THAN TOP OF CEE COLUMN.
I I
.5-3.75
6"x2 -1/2"x16 GA.
THAN TOP OF CEE COLUMN.
6"x2 -1/2"x16 GA.
FASTENER #B.5-1
ZEE BEAM
TYPICAL
FOR 8", 10" & 12"
4" X 2" X 16 � GALV. BOTTOM TRACK
9
VERTICAL PANEL SHOWN
I I
ALV. 1/2"x16 M GALV.
GALV. CEE COLUMN
�- CENTERLINE OF COLUMN
6 xCEE COLUMN
CENTERLINE OF COLUMN
I
I I
ANCHOR GEE COLUMN TO
12 GA. BASE ANGLE
12 GA. BASE ANGLE
I
I
TRACK W/ (1) 12x 3/4" TEK
ATTACH TO COLUMN W/X 1 A307 BOLT
(2)1/2"
1/2"x3-3/4" WEDGE ANCHORS OR EQUAL
ATTACH TO COLUMN(2)1/2"0(1)
(2)'1/2 "� X 1 A307 BOLT
(2) 1/2"x3--3/4" WEDGE ANCHORS OR EQUAL
BASE TRIM- RS101
I
FASTENER T1A PER SIDE
FASTENER #B.5-1
MINIMUM EMBEDMENT=3"
FASTENER #B.5-1
MINIMUM EMBEDMENT=3"
FASTENER #WA.5-3.75
FASTENER #WA.5-3.75.tr
--"--T
SLAB AND FOUNDATION 4" MIN.
SLAB AND FOUNDATION 4 MIN.
i
1 1/2
_.__
VIEW PERPENDICULAR
TO LENGTH OF
BUILDING
VIEM pERPENDICULAR
TO LENGTH OF BUILDING
SLAB AND FOUNDATION
BY OTHERS
3 ZEE BEAM COLUMN CONNECT_TON
4
ZEE BEAM COLUMN CONNECTION
PANEL TO STAB
CONNECTION
1")
—� 4" CEE COLUMN &
S— 5 6" CEE COLUMN &
6" ZEE BEAM
6" ZEE BEAM
SHE
4" GALVANIZED BASE TRI
FRAMING DRAWING
GROUND LEVEL —
' kSTENER #T1A BOTTOM CHANNEL
) CEE COLUMN
;18
REW 4" COLUMNS TOGETHER 2'-0" O.C.
3TENER #T1A
SHEETLEDGE
4" GALVANIZED BASE TRACK
SCREW 4" COLUMN TO CORNER PIER 2'-0" O.C.
FASTENER #T1A
JAMB TRIM—INSTALL BEFORE R—PANEL .
4C16 / ANOTE: CAULK ND CORNER PIER BETWEEN JAMB TRIM
11 1/4"
RAINLIP
\_ CORNER PIER
PIER AND HEADER SIDE WALL TO PANELED END
WALL & REAR SIDE WALL
ROOF PANELS
(1) 1/2"DIA.x1" BOLT
ZEE BEAM NOTE, PARTMON PANEL WILL BE A MAXIMUM
OF 8 BELOW ROOF OR FLOOR DECK
SEE
PLANS FOR
1 1/2" SHEETLEDGE
1X12X26ga GALVALUME PARTITION ANGLE
SIZE
AND LOCATION
PANEL IF GAP BETWEEN TOP OF
PARTITION AND UNDERSIDE AT
C -1
W/Cu
ROOF EXCEEDS 8" (NORMALLY ON
CPERCPILAN N
CEE COLUMN
BUILDINGS OVER 9'-0" TALL.)
r
177
LL
SEE PLANS FOR
12 X 3/4 TEK 0
6" O.C. VERTICALLY
SIZE AND LOCATION I I
FASTENER #T1A
12
di
X 3/4 TEK AT 2'-0" O.C.
PARTITION PANEL AND MO CAP POINT OF SCREW
J
w
ON OPPOSITE SIDE. APPLY MO CAPS ON SCREWS 6'-0" AFF
U—PANELGUAGE PER CONTRACT
5' X 15
5 X 15
a
10' X 10'
FL -11 0/S CORNER
CFF COLUMN PER PLAN
PARTITION PANELING
CS -1s THIS SIDE OF COLUMN
1 X 12 26ga GALVLUME PARTITION ANGLE MAYBE
PARTITION IF GAP BETWEEN
GAUGE PER CONTRACT
SAME LENGTH OF CEE COLUMN
I
ANGLE CLIPR—PANEL
W
USED TO EXTEND
TOP OF PARTITION AND UNDERSIDE AT ROOF
1/2" X 3 3/4" WEDGE ANCHOR
CS -1
W /0 CLIP
#WA .5-3.75
CLIP
W/1O0 CLIP
�
EXCEEDS 8". (NORMALLY ON BLDGS OVER 9'-0" TALL)
NOTE:—
I
THE PARTITION PANEL SHOULD BE
9 -10 3/;f" U -PANEL
CS -1
INSTALLED WITH THE PURLIN BEARING
9'-10 3/4- U -PANEL
LEG UPWARD.
W/O CLIP
PAR TI TION PANEL
w
w
CS -la THIS SIDE OF COLUMN
z
a
22ga CS -1
SAME HEIGHT AS COLUMN. FIELD
EA. END OF PART. WALT
FASTEN TO PIER TOP, I I
CUT To FI'T UNDER ZEE FLANGE
BOTTOM, AND MIDDLE I
# 12 x 3/4 'TEKS AT 20" O.C.
(ZEE NOT SHOWN FOR CLARIFY)
5' X 10'
5' X 10'
PLATE W/ 12 TEKS
FASTENER A I
(COVER EXPOSED PORTION OF SCREWS
10' X 10'
OR USE 1 SHOT PINS
W/ PLASTIC CAPS TO 6' A.F.F.)
24" O.C. FOR CMU OR
FASTENER #T1A
APPLY SCREW FROM OTHER
TILT WALL
SIDE OF PARTITION
I I
CEE COLUMN
W/CLIP
FASTEN PANEL TO CS -1 I
'`- ATTACH PANEL TO CEE COLUMN
PER PLAN
W/ #12 TEKS AT
W/ #12 TEK AT 6" O.C. VERTICALLY
6" O.C. (EVERY(EVERY
CORRUGATION)
CORRUGATION — TYP.)
FASTENER #T1A
FASTENER #T1A
PARTITION PANELING — TYPE "U"
GENERIC FRAMING FOR PARTITIONS
PARTITION WALL DETAIL
WITH CROSS PARTITIONS
SHE
4" GALVANIZED BASE TRI
FRAMING DRAWING
GROUND LEVEL —
' kSTENER #T1A BOTTOM CHANNEL
) CEE COLUMN
;18
REW 4" COLUMNS TOGETHER 2'-0" O.C.
3TENER #T1A
SHEETLEDGE
4" GALVANIZED BASE TRACK
SCREW 4" COLUMN TO CORNER PIER 2'-0" O.C.
FASTENER #T1A
JAMB TRIM—INSTALL BEFORE R—PANEL .
4C16 / ANOTE: CAULK ND CORNER PIER BETWEEN JAMB TRIM
11 1/4"
RAINLIP
\_ CORNER PIER
PIER AND HEADER SIDE WALL TO PANELED END
WALL & REAR SIDE WALL
ROOF PANELS
(1) 1/2"DIA.x1" BOLT
1 1/2" SHEETLEDGE
1X12X26ga GALVALUME PARTITION ANGLE
ZEE BEAM PER PLAN
MAY BE USED TO EXTEND PARTITION
PANEL IF GAP BETWEEN TOP OF
PARTITION AND UNDERSIDE AT
ROOF EXCEEDS 8" (NORMALLY ON
BUILDINGS OVER 9'-0" TALL.)
R -PANEL
LL
12 X 3/4 TEK 0
6" O.C. VERTICALLY
NOTE: APPLY STITCH SCREWS FROM THIS SIDE OF
FASTENER #T1A
12
di
X 3/4 TEK AT 2'-0" O.C.
PARTITION PANEL AND MO CAP POINT OF SCREW
ON OPPOSITE SIDE. APPLY MO CAPS ON SCREWS 6'-0" AFF
U—PANELGUAGE PER CONTRACT
FASTENER #T1A
FL -11 0/S CORNER
CFF COLUMN PER PLAN
SIDEWALL FRAMING
12ga BASE
ANGLE CLIPR—PANEL
1 1/2" SHEETLEDGE
1/2" X 3 3/4" WEDGE ANCHOR
#WA .5-3.75
NOTE:—
THE PARTITION PANEL SHOULD BE
INSTALLED WITH THE PURLIN BEARING
LEG UPWARD.
WALL FRAMING VER TI CAL EXTERIOR R --PANEL
PAR TI TION PANEL
SHE
4" GALVANIZED BASE TRI
FRAMING DRAWING
GROUND LEVEL —
' kSTENER #T1A BOTTOM CHANNEL
) CEE COLUMN
;18
REW 4" COLUMNS TOGETHER 2'-0" O.C.
3TENER #T1A
SHEETLEDGE
4" GALVANIZED BASE TRACK
SCREW 4" COLUMN TO CORNER PIER 2'-0" O.C.
FASTENER #T1A
JAMB TRIM—INSTALL BEFORE R—PANEL .
4C16 / ANOTE: CAULK ND CORNER PIER BETWEEN JAMB TRIM
11 1/4"
RAINLIP
\_ CORNER PIER
PIER AND HEADER SIDE WALL TO PANELED END
WALL & REAR SIDE WALL
if 2" X 1' HE)( HEAD BOLT -
B.5 -1
NOTE: NO WASHER THIS SIDE
OF CONNECTION,
PIER
12' MS -001
15' MS -003
16" MS -005
18" MS -007
PIER BOTTOM PLATE
12' MS -102
15' MS -110
16' MS -106
18' MS -114
PIER
FOR ROOF PITCH LESS THAN OR EQUAL TO 1/2 ON 12
RIDGE
1-12 "—_:.-1 i
T I T
-1/4-14 X 1' TEK
FASTENER jT1 B
PIER STIFFENER STRAP
MS -133-12,15,16' PIERS
MS -135-18' PIER
LOCATE AT 1/3 POINTS
1/4-14 X 1" TEK
FASTENER IT1B
1/2' X 1' HN -HEAD BOLT
FASTENER JBF.5-1.25
1/4-14 X 1" TEE(
FASTENER f rI B
RIDGE FLASHING FLAT
#14 X 7/8" ULTIMATE 1" TO EACH SIDE
OF ROOF SEAM AND OVER EACH MINOR RIB
FASTENER /TX4
TRI BEAD TAPE SEALER
ON TOP & BOTTOM OF 0/S CLOSURE
USE URETHANE TUBE CAULK AT
TRAPE70IDS TO FILL ANY GAP
HEYWEEN O/S CLOSURE AND
ULTRA-DEK
ROOF GLIP /.�"IIIr--4,STANDING SEAM ROOF SYSy
MIN. - 3"
MAX. - 8"
ZEE BEAM OR AS REWD IN PLAN
OUTSIDE CORN
9X9
MS -009
LOCATE AT LOWER EDGE OF
1/2' X 1" FIN -HEAD
W/WA.SHER INSIDE
#BF.5-1.25
PL -1 RIDGE CHANNEL
ATTACH TO ZEE W/ 112 X 3/4" TEK
AT 24" O.C.
FASTENER #T1A
5" 5"
/ OUTSIDE CLOSURE
ATTACH W/5 12x1" (MIN.) ULTIMATE SCREW
FASTENER #TX3 IN THE FLAT OF THE CLOSURE.
USE 2 #14X7/8" UL TIMATE INTO SIDE
OF ROOF PANEL AND 1 # 14X7/8 ULTIMATE INTO SEAM
FASTENER #TX4
RIDGE, SEC770_N
NOTE ON ROOF CLIPS:
UTILITY CLIP IS USED UP TO AND INCLUDING
3" OF INSULATION. LOW FIXED CLIP USED
W/ 4" INSULATION AND ABOVE.
ALL ROOF CI IPS FASTENERS: #14X1
FASTENER TIB
9X9 CORNER PIER
1/2' X 1' HEX HEAD BOLT
W/WASHER INSIDE
JB.5-1.25
NOTE: NO WASHER THIS SIDE
OF CONNECTION.
'4' TEK
IA
CORNER PIER
PLATE ANGLE 9 X 9
39
iE CORNER
J PLATE 9 X 9
.7
(1) APPLY TRI BEAD TAPE TO THE REAR
FLANGE OF THE GUTTER EXPANSION BOX.
CENTER THE G.E.B. ON THE PIER AND
ATTACH REAR FLANGE TO THE ROOF PAN
WITH (2) 1/4-14X718 EXTENDED LIFE
F
V
1
(2)
1
(3)
A
F
15!•�lL�
PIER AND HEADER
ASSEMBLY
;H SIDE
1E GUTTERS
;PANSION.
) THE G.E.B.
'0 THE GUTTERS.
(/) IN I tit UASL Wt -NL SC;UF'PLKS ARE REQUIRED, CUT OUT
THE BOTTOM OF THE G.E.B. TO THE INSIDE DIMENSIONS
OF THE SCUPPER. RMT SCUPPER TO THE BOTTOM OF
THE G.E.B.
CUTTER EXPANSION BOX INSTALLATION DETAIL
> BOLT
I
WASHER
OF
)N.
e
w
(3) 1/2" X 1' HEX HEAD BOLT
10.5-1
SIDEWALL HEADER 15'
MS -029
1/2' X 1' HEX HEAD BOLT
(TYP.) 10. 5-1
NOTE: NO WASHER THIS
SIDE OF CONNECTION.
PIER TOP PLATE 18'
MS -113
MULLION HEADER NJ
6�_� i �1FAASTENER I TIB
I Ij
I I
TOP/ MS -087 OM
12" MULLION
ti
PIER STIFFENER STRAP IB'
MS -135
PIER 18"
MS -007
I
MULLION ANGIF
TOP/ BOTTOM 1/4-14 X 1' TEK
MS -087 FASTENER i Ti8
,�1/2" X 1" [IN -HEAD BOLT
BF.5-1
PIER BOTTOM PLATE 18'
MS -114
PIER AND HEADER
ASSEMBLY W112" MULLION
-1/4-14 X 1" TEK
FASTENER T1 B
Design No, U425 - 12/21/2004
(F -or Exterior Walls, Ratings Applicable For Exposure To Fire ❑n Interior Face Only,
(See items 4 and 5)
Bearing Wall Rating 7 45 Min, 1, 1-1/2 or 2 HR, (See Items 2 and 4)
1. Steel Floor and Ceiling Tracks - (Not Shown) - Top and bottom tracks of wall assemblies shall consist
of steel members, min No. 20 MSG (0.0329 in., min bare metal thickness) steel or min No. 20 GSG
(0.036 in. thick) galv steel or No. 20 MSG (0.033 in. thick) primed steel, that provide a sound structural
connection between steel studs, and to adjacent assemblies such as a floor, ceiling, and/or other walls.
Attached to floor and ceiling assemblies with steel fasteners spaced not greater than 24 in. O.C.
2. Steel Studs - Corrosion protected steel studs, min No. 20 MSG (0.0329 in., min bare metal thickness) steel or
min 3- 1/2 in. wide, min No. 20 GSG (0.036 in. thick) galv steel or No. 20 MSG (0.033 in. thick) primed steel,
cold formed, shall be designed in accordance with the current edition of the Specification for the Design of
Cold -Formed Steel Structural Members by the American Iron and Steel Institute. All design details
enhancing the structural integrity of the wall assembly, including the axial design load of the studs, shall
be as specified by the steel stud designer and/or producer, and shall meet the requirements of all applicable
local code agencies. The max stud spacing of wall assemblies shall not exceed 24 in. OC (or 16 in.
OC - See Item 5c). Studs attached to floor and ceiling tracks with 1/2 in. long Type S-12 steel screws on
both sides of studs or by welded or bolted connections designed in accordance with the AISI specifications.
3. Lateral Support Members - (Not shown) - Where required for lateral support of studs, support may be
provided by means of steel straps, channels or other similar means as specified in the design of a particular
steel stud wall system.
4. Gypsum Board* - Gypsum wallboard bearing the ULI Classification Marking as to Fire Resistance. Applied
vertically with joints between layers staggered. Outer layer of 3 layer construction may be applied horizontally.
The thickness and number of layers and percent of design load for the 45 min, 1 hr, 1-1/2 hr and 2 hr ratings
are as follows:
_interior Walls
Ra -tin
Protectlon Both Sides Wall -No. of Layers & Thkns of Board In. Each Layers
Design Load
45 min
*1
layer,
1/2 in. thick
100
1 hr
*1
layer,
5/8 in. thick
100
1-1/2
hr *2
la ers,
1 2 in.thick
100
2 hr
*2
layers,
5/8 in. thick or
80
2 hr
*3
layers,
1/2 in. thick
100
2 hr
*2
layers,
3/4 in. thick
100
*Ratings applicable to assemblies serving as exterior walls where Classified fire resistive gypsum sheathing type
wallboard is substituted on the exterior face.
Exterior Walls
Ra -ting
Protection Both
Sides Wall -No. of Layers & Thkns of Board In. Each Lagers
Design Load
45 min
1 layer,
5/8 in. thick
100
1 hr
2 layers,
1/2 in.
thick
100
1-1/2
hr
2 layers,
5/8 in.
thick
100
2 hr
3 la ers,
1/2 in.
thick
100
2 layers,
3/4 in.
thick
100
gee Uypsum hoard cUKNX) Category - for naves of Classified Companies of 1/2 In, or 5/8 In, thick wallboard.
See below for Classified Company of 3/4 in. thick wallboard.
CANADIAN GYPSUM COMPANY - Type IP -X3, ULTRAC❑DE, ULTRAC❑DE SHC or ULTRAC❑DE WRC,
UNITED STATES GYPSUM CO - Type IP -X3, ULTRAC❑DE, ULTRAC❑DE SHC or ULTRACODE WRC,
USG MEXICO S A DE C V - Type IP -X3, ULTRAC❑DE, ULTRAC❑DE SHC or ULTRAC❑DE WRC,
4A. Gypsum Board* - (As an alternate to 5/8 in. thick wallboards in Item 4) ? Nam 3/4 in. thick.
CANADIAN GYPSUM COMPANY - Types AR, IP -AR,
UNITED STATES GYPSUM CO - Types AR, IP -AR.
USG MEXICO S A DE C V - Types AR, IP -AR.
5. Gypsum Sheathing - For exterior walls, 1/2 or 5/8 in. thick exterior regular gypsum sheathing applied vertically
and attached to studs and runner tracks with 1 in. long Type S-12 bugle head screws spaced 12 in. OC.
along studs and tracks. One of the following exterior facings are to be applied over the gypsum sheathing.
A. Siding, Brick, or Stucco - Aluminum siding, steel siding, brick veneer, or stucco attached to studs
over gypsum sheathing and meeting the requirements of local code agencies. When a rain 3-3/4 in. thick
brick veneer facing is used, the Exterior Wall Rating is applicable with exposure on either face. Brick veneer
wall attached to studs with corrugated metal wall ties attached to each stud with steel screws, not more
than each sixth course of brick.
B. Mineral and Fiber Boards* --- Exterior hard board paneling, chemically treated over gypsum sheathing
with primed or finished face, 7/16 in. thick by 48 in. wide. Attached to studs over gypsum sheathing with
1-7/8 in. long bugle -head TEK fasteners 16 in. OC at the intermediate supports Or, exterior lap siding,
chemically treated, 7/16 in. thick by 8 in. or 12 in. wide. Attached to studs with 1-7/8 in. long, bugle -head
Type TEK fasteners at each lap. Panels lapped minimum 1 in.
MASONITE CORP - Type FT.
C. Cementitious Backer Units* - 1/2 or 5/8 in. thick, square edge boards, attached to steel studs over
gypsum sheathing with 1-5/8 in. long, Type S-12, corrosion resistant, wafer head steel screws, spaced 8 in.
OC. Studs spaced a max of 16 in. OC. Joints covered with glass fiber mesh tape.
UNITED STATES GYPSUM CO - Durock Exterior Cement Board or Durock Brand Cement Board.
D. Fiber -Cement Siding - Fiber -cement exterior sidings including smooth and patterned panel or lap siding.
E. Molded Plastic* - Solid vinyl siding mechanicaly secured to framing members in accordance with
manufacturer's recommended installation details.
AL SIDE, DIV OF
ASSOCIATED MATERIALS INC
HEARTLAND BUILDING PRODUCTS INC
NEBRASKA PLASTICS INC
6. Fasteners - (Not Shown) - Screws used to attach wallboard to studs: self -tapping bugle head sheet steel type,
spaced 12 in. O.C. First layer Type S-12 by 1 in. long for 1/2 and 5/8 in. thick wallboards and 1-1/4 in. long
for 3/4 in. thick wallboard. Second layer Type S-12 by 1-5/8 in. long for 1/2 and 5/8 in. thick wallboards and
2-1/4 in. long for 3/4 in. thick wallboard. Third layer Type S---12 by 1-7/8 in. long.
7. Batts and Blankets* - Placed in stud cavities of all exterior walls. May or may not be used in interior walls.
Any glass fiber or mineral wool batt material bearing the UL Classification Marking as to Fire Resistance,
of a thickness to completely fill stud cavity.
See Batts and Blankets (BZJZ) Category for names of Classified Companies.
7A. Fiber, Sprayed* - As an alternate to Batts and Blankets (Item 7) - Spray applied cellulose material. The fiber
is applied with water to completely fill the enclosed cavity in accordance with the application instructions
supplied with the product. Nominal dry density of 3.0 Ib/ft3. Alternate application method: The fiber is applied
with U.S. Greenfiber LLC Type AD100 hot melt adhesive at a nominal ratio of one part adhesive to 6.6 parts
fiber to completely fill the enclosed cavity in accordance with the application instructions supplied with -the
product. Nominal dry density of 2.5 Ib/ft3.
U S GREENFIBER L L C --- Cocoon2 Stablllzed or Cocoon-FRM (Fire Rated Material)
9. Joint Tape and Compound - (Not Shown) - Vinyl or casein, dry or premixed joint compound applied in two
coats to joints and screw heads of outer layer. Perforated paper tape, 2 in. wide, embedded in first layer of
compound over all joints of outer layer.
8. Furring Channels - (Optional, not shown, for single or double layer systems) - Resilient furring channels
fabricated from min 25 MSG corrosion -protected steel, spaced vertically a max of 24 in. OC. Flange
portion attached to each intersecting stud with 1/2 in. long Type S-12 steel screws.
*Bearing the UL Classification Mark
HORIZONTAL SECTION
EXTERIOR WALL
INTERIOR ( Ft ) SIDE
HORIZONTAL SECTION
STANDING SEAM ROOF /-- ROOF CUP AS REQUIRED
'UL CLASS A' RATING ---% /
(2) 1/4-14. X1 TEK TOPS TRACK
FASTFE� ]21p, GALVANEAL—j
STRAP (2 BETWEEN ZEES)
(TYP ON 20" CENTERS)I I 12-14 X 1 TEK PANCAKE HEAD
FASTENER IT12
ZEE BEAM PER PLANY I I (1) LAYER 5/8" FIRE RATED GYP. BD
APPLY VERTICALLY
((
/ I I — 4" X 20ga STUDS MIN. AT
(1) LA GYP. BOARD ROE RATED GYP. BD 24" O.C.
OR CEE PER PLAN
ROOF DECK WITH TAPE INSTALL 2 ADDITIONAL
AND DRYWALL COMPOUND ROOF CUPS BETWEEN ZEES TYP.
ON 20" CENTERS
(2) 1/4-14 X 1 TEK
FASTENER TIB
STANDING SEAM ROOF PER CUP
SECTION 1 ULTRA DEOR
/-20go MIN.
'UL CLASS A' RATING / TOP TRACK
t — t
ZEE BEAM AS REQUIRED
(SEAL 1) IAS 5/gip IRE RATED GYP. BD I
II III OR Q EC PER PLAN MIN. AT I
REVISIONS FIRE WALL FRAMING TO CEILING AS,5EMBLY
#U-425
SECTION 2
REVISIONS
STANDING SEAM ROO
'UL CLASS A' RATING
ZEE BEAM PER PIANS
CUT GYP. BOARD AROUND ZEE AS 11GHT AS —
POSSIBLE. PIECE CUT GYP. BOARD BACK INTO
ZEE AREA AND SEAL WITH TAPE AND DRYWALL
COMPOUND.
(1) LAYER 5/8" FIRE RATED GYP. BOARD
SEAL GYP. BOARD TO
ROOF DECK WITH TAPE
AND DRYWALL COMPOUND
NOTE: ATTACH GYP BOARD AND --T—'
TAPE ZEE PENETRATIONS AND SEAMS
AS STATED BY #U-425
CUT AND INSTALLED BETWEEN
STRUCTURAL COLUMNS
20ga MIN. —
BOTTOM TRACK
ATTACH FIREWALL FRAMING
TO ROOF SYSTEM ON 2'-0"
CENTERS SEE DETAIL SECTIONI OR SECTION2
—`-20ga MIN.
TOP TRACK
(1) LAYER 5/8" FIRE RATED GYP. BOARD
AAPPPLY VERTICALLY
4" X 20ga STUDS MIN. AT
24" O.C.
IF INSULATION IS INSTALL IT SHOULD NOT BE CONTINUOS
OVER FIREWALL. CUT VINYL ® CENTER OF FIREWALL AND FOLD
BACK TO EDGE OF FIREWAILL ON BOTH SIDE AND SECURE WITH TAPE.
TO ALLOW DRYWALL TO BE INSTALLED TO BOTTOM OF ROOF MATERIAL.
SEE DRAWING BELOW.
SHOT PINS 24" o.c.
BEARING 1 HOUR RATED WALL PER #U-425
ATTACH STUDS TO TRACK W/
# 8-18 X 1/2" LONG PINHEAD
EACH SIDE 24" O.C. MAX.
FASTf NER #144