HomeMy WebLinkAbout4585 St Johns Pkwy (hood) + (a) (2)W _. - ..._..—+.•-- =—•.,n- �..^_ _.,-..r.. .... ... ,.c � is . .. REMARKS: A, Removable grease catcher $, UL listed vapor light with wire safety guard. C, Baffle filter set 45 degree. UL listed. (821U). Filter size: 2511 x 20"W x 2"D. No. of filter: 14. D. UL listed fire damper. E. Ducts constructed of No, 16 MSG steel with all scams, joints, and penetrations welded as li d ti ht r N1FPA code 96 �SA NOTE: AIR CONDITIONING SYSTEM 15 EXI5TING AND SHALL REMAIN. NOTE: 13UILDING PRESSURIZATION = =O.A. - E.A. x 100% E.A. = 8660 - 9675 x 100% 9675 -10.4% AIR'PALANCE CHART (CFM) UNIT N0. SUP LY RETURN OUTSIDE AIR EXHAU5T . AIR RTU 2000. WEIGHT (LB) 500 HP MUA(KITCHEN) , 75 8160 1200 EF- l (KITCHEN) 1/4 208/20/1 ALUMINUM RUB RING 4800 EF-2(KITCHEN) i I CURB GPNS-17-G8 EXHAUST FAN 4800 EF: 3(T01LET) MAKE & MODLE NO. VOLUME CF SPFAN IN WC 75 TOTALS MOTOR SPECS f QIP . 8560 9675 CALCULATIONS: HOOD: 4' x 24' x 100 = 9600 CFM FAN: (2) 2 HP EXHAUST, 5i:.` .' MAKE-UP EXHAUST DUCT SIZE: 18" x 18" / 144 = 2.25 SO. Fr. EXHAUST DUCT AiR VELOCHT: 960012/2,25 = 2133 FPM MAKE-UP AIR: 85% x 9600 = 8160 CFM MAKE-UP AIR DUCT SIZE: 23" x 24" qui g as pe i R Hood constructed of No, 18 MSG stainless NOTE: steel, type 304 with fresh air return, All connection IN5TALL 5TAINLE55 STEEL ON THE and seams were welded as liquid -tight to meet WALL BEHIND KITCHEN EXHAU5T NFPA code 96 standard ,NSF listed No. 1499. HOOD AND EXTEND A MIN, OF 18" G. Existing masonry wall with 26ga. stainless steel surface. BEYOND THE HOOD IN ALL H. Fire supression nozzle. DIRECTIONS I. Roof curb. GENERAL ROTES: 1, Ventilators qid installation MUST comply with NFPA code 96 plus all local fire codes. 2. Hood MUST be constructed of not less than 18ga, stainless steel. All seams, joints, and penetralons shall have a liquid -tight continuous external weld. (2-1,2) 3. Ducts MUS;F be constructed of not less than 16ga, carbon steel, All seams, joints, and penetraion shall be continuous external weld as liquid -tight. (3-3,1) 4. Make-up aij( MUST be not less than 80% of total exhausted air. 5. The fire exfnguisher system MUST be installed by a local liscensed company, separate plai must be submitted to local Fire Dept. for approval. 6. All electric+! work MUST be done by local liscensed electrician. 7. Hood to be lung 3" away from the fire -protected wall. 2 HF 20" -MIN.- —120" MIN. 2 HP EF- I 5 HP EF -2 MUA- I "MIN_ oQ 11 MIN Q I ° MIN AIR SPACE AIR 5PACF — AIR 5FAC Roof flow ir 23° X 24° E PROCA5T FA5T ® /( FKOCA5T FAST PROCA5T FAST 0 DUCT WRAP DUCT WRAF DUCT WRAP Make-up lir E 0 CLEARANCE —d' —� 0 CLEARANCE 0 CLEARANCE_ � Fan Duct Air' Air Exhaust FIOW F10W Fan Duct 14' X 14° 14" x I ' ceiling FI—DANPEK FIRE DAMPER 3" AIR SPACE F U �!Hood Length 24' G A. 13 48" ,�" 5alarnander m � Deep Rlce Mke tn. Fryer Back 51a5h Hose Cooker �?? Wok Stove m � m Floc SIDE FRONT VENTILATION PLAN (NIX.S.) LEGEN.D: S/A SUPPLY AIR GRILL AIR CONDITION .UNIT 5CHEDULE: R/A RETURN AIR DIFFUSER MANUFACTURE: LONNOX MODEL: CHP20-060 I Y (5 •TON5) (D THERMOST TOTAL AIR FLOW: 2000 CFM FLEXIBLE AIR DUCT OUTDOOR AIR REQUfREMENTS �PER FMC 403.3 LJ f DUCT SMOKE DETECTOR FOOD AND BEVERAGE - WAITING AREA 5 PEOPLE @ 20 CFM/PERSON = I GO CFM REQUIRED ?SIR DISTRIBUTION 400 CFM PROVIDED DUCT 0' FROM (CFM) TO (CFM) FOOD AND BEVERAGE - KITCHEN 101 400 4 PEOPLE @ 15 CPM/PER50N = GO CFM REQUIRED 401 680 100 CFM PROVIDED FAN REMARK: TOILET QTY, 1 _EXHA.UST MAKE & MODLE NO. VOLUME CF SP WC FAN RPM WEIGHT (LB) MOTOR SPECS HP V/C/P COOK GC -120 75 0.125 1200 15 1/4 208/20/1 ALUMINUM RUB RING SWITCG - NEMA -1, TOGGLE, MOUNTED $ WIRED MOTOR W/ THERMAL OVERLOADS UL - 705 - "POWER VENTILATORS" CURB GPNS-17-G8 EXHAUST FAN REMARK: KITCHEN • TTY: 2 MAKE & MODLE NO. VOLUME CF SPFAN IN WC RPM WERGIIT (LB) MOTOR SPECS f QIP . V/C/P_ M VENTILATION FX -16a 4800 0.25 1389 200 i t . 208!60/3 UL 821 BAFFLE TYPE GREASE FILTER AGI-:LVANIZED STENTED PREMA14UFACTURED ROOF CURB GREASE TRAP WITH DRAIN CONNECT HINGING KIT -FIELD INSTALLED MAKE-UP AIR UNIT REMARK : KITCHEN QTY, 1 MAKE & MODLE NU. VOLUME CF SP WC FAN RPM WEIGHT (LB) MOTOR SPECS HP V/C/P. NN VENTILATION MU5018 8160 0.25 580 250 5 208/60/3 CONTROL CENTER -COMBINED SWITCHING UL LISTED FIRE DAMPER AILUhl VV/ 31RD BARRIER VEW PETAIL (H.W. HEATER) d - N z ROOF • LASHING 7 1;HR jENANT gEf�ARATIQN WALL, MIN,:` 3: F1R. ;RATED...., . ;IRE BLANKET •WRAP I:..:..:.. 116 GA, -ALV.: ....... EXHAUS.T:AU0T H,0.0D I'LAN NOTE:, .- THE l7UGT FIRE RAfL0, 1N0SHALL.- flL: APPLIED" ONL'1 TO :SEPARATE' ANY CaNj=- BUSTABLE. MMERIAL .WITHIN-, 18" :OF -THE EXHAUST DUCT, REMOTE MANUAL PULL u D �r 5TATION MIN. I G-0" AND HOOD FIRE SUPPRESSION -L`l SYSTEM (N.T.S.), MAX. 20-0" FROM HOOD i NOTE: ACTIVATION OF FIRE 5UPPRE55ION 5Y5TEM 5HUT5 OFF ALL FUEL 50URCE5, GAS AND ELECTRICITY UNDER THE HOOD INCLUDING 5UPPLY AIR, LEAVES EXHAUST FAN RUNNING, n REVIEWED CURE, (20, GA;, CONSTRUCTION) iyoTe: , EXHAUST FAN CUR© (APPROXI 30":530"X12" ADOV� ROOF) 18 GA. 5HE;ET M.T`L,. EXHAU ST FAN: FLASHING COLLAR N,T S. P%, Em " �Ufl I T - #C�i a ` w o fan#Ord Fir 'Pr VDW. `D 1V a 1' ,,-- 0 C T n -, 700.5 Fire Dept. Finallnsp.,� y.. Date:C C11 J F) ra ? FRANK D. MILETO A.I.A. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 / (908) 876-9400 �\ NLESS SEALED A'°°°°4 ARCHITECT -PROFESSIONAL PLANNER L1°2812 CHINA STAR 5T. JOHNS PLAZA RINEHART ROAD 5T. JOHNS PARKWAY 5ANFORD, FL SCALE: 1/4"=1'-Q" DRAWING NO.: 14405 DRAWN BY: JU DATE: 04/27/05 IVl-1 (3 of 4) REVISED: VENTILATION PLAIT, HVAC PLAN, HOOD FIRE SUPPRESSION SYSTEM FOOD SERVICE CONSULTANT LAM CONSULTING COMPANY, INC. 108 MADISON STREET, NEW YORK, NY 10002 PHONE: 212-732-3450 FAX: 212-732-9145 NOTE: AIR CONDITIONING 5Y5TEM 15 EXI5TING AND 5HALL REMAIN, NOTE: BUILDING PRE55UKIZATION =O.A. - E.A. x 100% E.A. = 8660 - 9675 x 100% 9675 _ -10.4% REMARKS: A Removable rease catcher (4-12 2 6) g B. UL listed vapor light with wire safety guard. C. Baffle filter set 45 degree. UL listed. (821U). Filter size: 25"H x 20"W x 2"D. No. of inter: 14. D. UL listed fire damper. E. Ducts constructed of No. 16 MSG steel with all seams, joints, and penetrations welded as liquid -tight as per NFPA code 96. HVAC PLAN SCALE: 1/4"=F-0"1 AIR BALANCE CHART (CFM) UNIT N0, 5UPPLY RETURN OUT5IDE AIR EXHAUST AIR RTU 2000 SUPPLY AIR GRILL 500 680 MUA(KITCHEN) R/A 8160 EF- I (KITCHEN) O THERMOST �'--- 4800 EF-2(KITCHEN) DUCT SMOKE DETECTOR MAKE-UP AIR UNIT REMARK: KITCHEN 4800 EF-3(TOILET) Fane�uct r E VOLUME CFM 75 TOTAL5 WEIGHT (LB) MOTOR SPECS 8660 9 CALCULATIONS: HOOD: 4'x 24'x 100 = 9600 CFM FAN: (2)1 1/2 HP EXHAUST, 511P MAKE-UP EXHAUST DUCT SIZE: 18" x 18" / 144 = 2.25 SQ. FT. EXHAUST DUCT AIR VELOCITY: 9600 / 2/2.25 = 2133 FPM MAKE-UP AIR: 85% x 9600 = 8160 CFM MAKE-UP AIR DUCT SIZE: 23" x 24" F. Hood constructed of No. 18 MSG stainless NOTE: steel, type 304 with fresh air retum, All connection IN5TALL 5TAINLE55 STEEL ON THE and seams were welded as liquid -tight to meet WALL BEHIND KITCHEN EXHAUST NFPA code 96 standard .NSF listed No. 1499. HOOD AND EXTEND A MIN. Of 18" G. Existing masonry wall with 26ga. stainless steel surface. BEYOND THE HOOD IN ALL H. Fire supression nozzle. DIRECTION5 1. Roof curb. I-- I" MIN_ DUCT 0 FROM (CFM) TO (CFM) AIR 5PACE �' --- 200 11 SUPPLY AIR GRILL 401 680 UL 821 BAFFLE TYPE GREASE FILTER R/A N E O THERMOST �'--- PKOCA5T FA5T S�---. DUCT SMOKE DETECTOR MAKE-UP AIR UNIT REMARK: KITCHEN DUCT WRAF 0 CLEAPANCE — Fane�uct r E VOLUME CFM SP IN WC Exhaust WEIGHT (LB) MOTOR SPECS HP V/C/P Fan Duct PENN VENTILATION MU5018 8160 0.25 580 3" AIR 5PACE 5 208/60/3 CONTROL CENTER COMBINED SWITCHING G C D N A 48"e X -12"- v Min. �o m m SIDE 675 GENERAL NO'T'ES: 1. Ventilators andnistallation MUST comply with NFPA code 96 plus all local fire codes. 2. Hood MUST be constructed of not less than 18ga, stainless steel. All seams, joints, and penetrations shall have a liquid -tight continuous external weld. (2-1.2) 3. Ducts MUST be constructed of not less than 16ga. carbon steel. All seams, joints, and penetration shall be continuous external weld as liquid -tight. (3-3.1) 4. Make-up air MUST be not less than 80% of total exhausted air. 5. The fire extingidsher system MUST be installed by a local liscensed company, separate plan must be submitted to local Fire Dept. for approval. 6. All electrical work MUST be done by local liscensed electrician. 7. Hood to be hung 3" away from the fire -protected wall. 1 1/2 HP L 0" MIN.120" MIN. 1 1/2 HP EF- I 5 HP EF -2 — MUA- I 0 0 Air _ PROCA5T FA5T r9—� �--^ �t Flow --23" X 24" -~- ROCAST FA5T 0 DUCT WRAP I � `v DUCT WRAP 0 CLEARANCE l+ 0 CLEARANCE --�— --- < Air it Flow Flow __-14" X 14" ----- 14" X 14"- FIRI~DAMPEP. FIRE DAMPER__- FIRE RATED CEILING TI IF ol —Hood Length 24' 5alamander Deep Race Fryer° Back slash Smoke Cooker House Wok 5tove nF F1 � —r -- 0 FRONT VENTILATION PLAN (N.T.S.) WALL CAP LEGEND. AIR DISTRIBUTION DUCT 0 FROM (CFM) TO (CFM) S/A 200 11 SUPPLY AIR GRILL 401 680 UL 821 BAFFLE TYPE GREASE FILTER R/A N RETURN AIR DIFFUSER O THERMOST �'--- FLEXIBLE AIR DUCT S�---. DUCT SMOKE DETECTOR AIR DISTRIBUTION DUCT 0 FROM (CFM) TO (CFM) 1261 200 11 12" 401 680 MTL CAP W/ FILTER R BARRIER AIR INTAKE EXHAUST FAN REMARK :TOILET QTY, I r -- -- l[HRouCH FILTER MAKE & VOLUME SP FAN WEIGHT MOTOR SPECS CuRB (20 .0: CONSTRUCTION) MODLE i'.10.CFM IN WC RPM (LB) HP WC/P J - 3" CONTINUOUS FL .sHlno COOK GC -120 75 0.125 1200 15 1/4 208/20/1 NOTE: MAKE—UP A FAN CURB ALUMINUM RUB RING (AFPROX 38"X38"X;12" 'ABOVE ROOF) 18 GA. SHEtT,MTL. SWITCG - NEMA -1, TOGGLE, MOUNTED $ WIRED — — MAKEUP FAN FLASHING COLLAR N.T.S. MOTOR W/ THERMAL OVERLOADS UL - 705 - "POWER VENTILATORS" CURB GPNS-17-G8 5TORM EXHAUST FAN REMARK: KITCHEN QTY: 2 COLLA!; I " MAKE & VOLUME SP FAN WEIGHT MOTOR SPECS —ADJUSTABLE ROOF LA5HING MODLE NO, CFM IN WC RPM (LB)HP V/C/P EX15TING ROOF z = CURB (20 CA, OCNv i (RUCHON) UL LISTEll FIRE DAMPER VENT DETAIL (H.W. HEATER) PLENUM PLENL1101 NUZZLILt) #NLA #NLA FU5I15LE LINKFUSIBLE LINK 360 DEGREES PLENLIM NOZZLES PLENLIM O�ZZLES 360 DEGREES #NLA Roof PYRO CHEM MODEL # PCL3.50/3.50 PR'ER NOZZLES LIQUID UL 300 #NLRF2 WOK NOZZLES FIRE 5UPPRE5510N #NLR 5Y5TEM W/27 112 Ceiling IFLEM POINT5. 0 O X LL= 000 O SMOKE RICE/ DEEP FRYER 1,0 HOUSE COOKER AUTOMATIC GA5 VALVE REMOTE MANUAL PULL STATION MIN, 10'-0" AND HOOD FIRE SUPPRESSION SYSTEM (N.T.S.) MAX. 20'-0" FROM HOOD Floor NOTE: ACTIVATION OF FIRE 5UPPRE55ION 5Y5TEM 5HUT5 OFF ALL FUEL 50UKCE5, GA5 AND ELECTRICITY UNDER THE HOOD INCLUDING 5UPPLY AIR, LEAVES EXHAUST FAN RUNNING. ti NOTE: EXHAUST FAN CURB (APPROX. 30"X30"X92" ABOVE RCJF) 18 CA, SHEET MTL,. EXHAUST FAN FLASHING COLLAR N.T.s. PLANS 1? ION CITY OF SA P&MMITs REVIEWED By: Sanford Fire Rev Di. Date; FRANK D. MILETO A.I.A.,,. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 R 0540 VALID (908) 876-9400 t N ESS SEALED ® ARCHITECT -PROFESSIONAL PLANNER Atoeoaa L 10261 Will 4VUU PENN VENTILATION FX-16B(FT) 4800 0.25 1261 200 11 208/60/3 UL 821 BAFFLE TYPE GREASE FILTER GALVAi` ZED VENTED PREMANtJVACTURED ROOF CURB GREASE :! ".P WITH DRAIN CONNECT HINGING YJT -FIELD INSTALLED MAKE-UP AIR UNIT REMARK: KITCHEN QTY, 1 MAKE & MODLE 1'10. VOLUME CFM SP IN WC FAN RPM WEIGHT (LB) MOTOR SPECS HP V/C/P PENN VENTILATION MU5018 8160 0.25 580 250 5 208/60/3 CONTROL CENTER COMBINED SWITCHING UL LISTEll FIRE DAMPER VENT DETAIL (H.W. HEATER) PLENUM PLENL1101 NUZZLILt) #NLA #NLA FU5I15LE LINKFUSIBLE LINK 360 DEGREES PLENLIM NOZZLES PLENLIM O�ZZLES 360 DEGREES #NLA Roof PYRO CHEM MODEL # PCL3.50/3.50 PR'ER NOZZLES LIQUID UL 300 #NLRF2 WOK NOZZLES FIRE 5UPPRE5510N #NLR 5Y5TEM W/27 112 Ceiling IFLEM POINT5. 0 O X LL= 000 O SMOKE RICE/ DEEP FRYER 1,0 HOUSE COOKER AUTOMATIC GA5 VALVE REMOTE MANUAL PULL STATION MIN, 10'-0" AND HOOD FIRE SUPPRESSION SYSTEM (N.T.S.) MAX. 20'-0" FROM HOOD Floor NOTE: ACTIVATION OF FIRE 5UPPRE55ION 5Y5TEM 5HUT5 OFF ALL FUEL 50UKCE5, GA5 AND ELECTRICITY UNDER THE HOOD INCLUDING 5UPPLY AIR, LEAVES EXHAUST FAN RUNNING. ti NOTE: EXHAUST FAN CURB (APPROX. 30"X30"X92" ABOVE RCJF) 18 CA, SHEET MTL,. EXHAUST FAN FLASHING COLLAR N.T.s. PLANS 1? ION CITY OF SA P&MMITs REVIEWED By: Sanford Fire Rev Di. Date; FRANK D. MILETO A.I.A.,,. 14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 R 0540 VALID (908) 876-9400 t N ESS SEALED ® ARCHITECT -PROFESSIONAL PLANNER Atoeoaa L 10261 Will 4VUU