HomeMy WebLinkAbout2441 Cherry Laurel Dr + (a) fire tie inciv c 7
MAY 242012
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: '� /� (P �A 0-1— Documented Construction Value: $3t4,
J D lJ
Job Address: C4t er r q rP,� Dr. C 11 � ((� Historic District: Yes ❑ No x
Parcel ID• 30-3D! - f o''c too D Zoning:
Descriptio Jlor -� i - 0t78'F — a v S 1 e_ X- i re • ie_ 1 A
Plan Review Contact Person: 17 `? M AC NCLAka,( LL Title: (rest jeh "t
Phone: 40I 4tl c6%9 Al - i0I Fax. $�%`3Ja "�q73- E-mail: �j • cop"
1 Property Owner jInformation
Name �* S4oj �1-oL) P Dt7e 5",,t-crj Ear7I1Q�"5 Phone:
Street: .3a!5 SEc� �f�G�-� L1'i . Z� Resident of property? : /J
City, State Zip: P- 0"I K(i 11, IX) %4& -7
Name
Street:
Contractornformatio,
SL�Uy-� �ev� I� vu�7j ' Pd1�7�r• ` hone
3
-/J-. , Fax: _
City, State Zip ! ��� State License No.: b 773 aZ R000/o2(0
0 9 ii Arch itect/Eng_ineer Information
Name: /�,ftC�tG� 14400 f hed + a 1 o n4 Phone:
A107.977- r I"
S144? - 33z• CZ -72 --
Street:
City, St, Zip:
Fax:
E-mail:
Bonding Company: L, 13,ef Mortgage Lender: I sT •Tenn ss, e e . k AJ A
Address: 115 13ff K, I QM t Address: 15kl �) A i.1 irT f ee5 bo ro gd
Building Permit ❑
Square Footage:
No. of Dwelling Units
Electrical ❑
54y
New Service - No. of AMPS:
PERMIT INFORMATION
Construction Type:
Flood Zone:
Mechanical ❑ (Duct layout required for new systems)
ir2'3 �
No. of Stories:
Plumbing ❑
New Construction - No. of Fixtures:
Fire Sprinkler/Alarm ❑ No. of heads:
o
••..►,err
R
4 X 2 1/2" X 2 1/2" FDC
r
90 DEGREE PATTERN
'
W/ BREAK—AWAY CAPS
z
P
GALV. SCH-40
M a
1 ■
2
■
3
■
4
■
5
■
6
■
7
■
8
■
9
■
10
■
11
■
12
■
13
■
14
■
15
■
16
■
17
■
18
■
19
■
20
R
4 X 2 1/2" X 2 1/2" FDC
90 DEGREE PATTERN
'
W/ BREAK—AWAY CAPS
z
P
GALV. SCH-40
M a
GRADE
WIDE FLANGE
■
(FOR STEEL PIPE)
GRAVEL FOR DRAINAGE
WAFER CHECK VALVE
1/2" TREAD—O—LET WITH
1 /2" AUTO—BALL DRIP CHECK VALVE
UNI—FLANGE
(FOR DIP PIPE)
DIP
DR -14 C900 PIPE
MJ TEE
■
TO BUILDING RISER
FLOW —+►
SEE PLAN
N
FIRE DEPARTMENT CONNECTION DETAIL (FDC)
NO SCALE
■ UNDERGROUND FIRE NOTES
OPROPOSED 12" WATER LINE
(REFERENCE ONLY)
O2 PROPOSED 10" BACK FLOW
■ GROOVED VICTOLIC END (REFERENCE ONLY)
U_
a O3 12"X4" TEE
z
L FINISHED FLOOR
GRADE SLEEVE THOUGH SLAB O 12"X6"TEE
FOOTER 5 4" BFP W/ TAMPER SWITCH
CIPS-:: couwuNG MASES 6 6" BFP W/ TAMOER SWITCH
WITH C900 P)PE
TIE—ROD BRACKET
K 7 POINT OF SERVICE
SOLID ONE PIECE CONSTRUCTION O FIRE HYDRANT (SEE DATAIL)
WELDED JOINTS UNIT PRE—TESTED
' AT FACTORY 9 INLINE CHECK VALUE
AMES IN BUILDING RISER
10 FDC (SEE DETAIL)
NO SCALE 11 1 FT RIASER INSIDE BUILDING
(SEE DETAIL THIS SHEET)
12 37LF 6" C900 DR -14
FIRE
HYDRANT 13 51 LF 4" C900 DR -14
H 4 1/2' PORT TO FACE STREET O
INSTALL HYD, 18' OFF CURB 18' MIN. 6' BELOW BURY LINE
OR 5FT OFF CURB IN ISLANDS 24' MAX. 14 19LF 4" C900 DR -14
.........FFINISH ........._ � .__..................._ GRADE
.............................::.. .
■ PAVEMENT
15 87LF 4" C900 DR -14
6' GATE VALV
W/B❑x 16 A 205LF 4" C900 DR -14
G
A
0
■
SUPPORT BLOCK
M,J. TEE OR A 6' D,I, PIPE STUB
TAPPING SLEEVE
6' D. I.
F PIPE STUB A — MEGALUGS
NOTE:
A 6" ELL IS REQUIRED BETWEEN THE VALVE AND
HYDRANT PARALLEL TO WATER MAIN WHEN:
■ 1. TEE FACES TOWARD ROADWAY.
2. TEE FACES TOWARD BUILDING.
3. THE MAIN IS 12" OR LARGER.
* LONG HYDRANT LATERALS OVER 20' MAY REQUIRE 2 VALVES
E * HYDRANT BURIED LINE TO BE WITHIN 2" OF FINISH GRADE.
* INSTALL TRACER WIRE ALONG PIPE, UP VALVE & HYDRANT.
• TYPICAL FIRE HYDRANT DETAIL
NO SCALE
D
GENERAL NOTES -
1 .
ALL UNDERGROUND FIRE MAIN PIPING SHALL BE INSTALLED IN ACCORDANCE
C WITH NEPA #13 AND #24, 2002 OR LATEST EDITIONS.
2. SCOPE OF WORK TO COMMENCE AS INDICATED ON THE SITE PLAN.
3. UNDERGROUND PIPING SHAL BE DR -14 C900 PVC FOR PRESSURES
EXCEEDING 150PSI.
4. CHANGES IN DIRECTION OF PIPING TO BE MADE BY USE OF MECHANICAL JOINT FITTINGS.
B 5. THRUST RESTRAINTS TO BE PROVIED AT ALL TURNS AND ENDS OF MAIN PER NEPA #24, 2002.
6. FLUSHING AND TESTING OF UNDERGROUND PIPING TO BE PREFORMED AS PER NEPA #24, 2002.
7. ALL INDICATING CONTROL VALVES TO BE PROVIDED WITH TAMPER SWITCHES.
8. DEPTH OF COVER TO BE MINIMUM 36 INCH.
A
1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 ■
GRAPHIC SCALE
30 0 15 30 60
( 1 IN = 40 FEET )
LEGEND:
FIRE HYDRANT ASSEMBLY
FIRE DEPARTMENT
CONNECTION (FDC)
- RPZ BACKFLOW PREVENTOR
_ DOUBLE DETECTOR
CHECK VALVE
Uj V
Z
fV
00
a f V 0p
OZ Mo
miOQ M o
�ko
U � cn N 00 0
j >_I J X N
V��M I-)
W o
D `
Q Ne 00
Q0 o
Z l� J >
� U
Lu Z
I� U
x 0 O
I -D Ca V �-
t
CL
0
t vii . "Oi I
'In Rob � /
IrdF' a t.
UNDERGROUND
FIRE PERMIT
PROJECT:
SOLARA
1 CHERRY LAUREL
SANFORD, FL
t-r,UJ. NU.E-09100.00 SHEET
DRAWN
UG -1
7 ■ 8 ■ 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ 16 ■ 17 ■ 18 ■ 19 ■ 20
Copyright HuntonBrady Architects P.A. All Rights Reserved. 800 N. Magnolia Ave., Suite 600, Orlando, Florida 32803 (407) 839-0886 (407) 839-1709/Fax www.huntonbrady.com License AAC001744