Loading...
HomeMy WebLinkAbout165 Towne Center Cir (a) (2)RECEIVED J1��y v 2008 CITY OF SANT RO PERMIT APPLICA'T14N (4Permit # : 6 - 05D� ate: D -7I4 1s J b Add P • <aLA U,4 -e, ?oOo ,i D I vbv: Description or Work: �� "' � u✓ A2s �—n 'S`�'� 'Total Square Foom e 3 3 02 Y'listoric District: 'Zoning: Value or Wurk: S k' , 400 . U J _ Pormit Type. Building .)<' Electrical Mechanical Plumbing Firc Sprinkler/Alarm Pool Electrical: New Smice - # of AMPS Addition/Alterauon Change of Servir c TemporaryPolc Mechanteal: Residentixi Dion -Residential,)("' Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixturos _ , # of Water & Scwcr Lutes # of Gats Lincs PJuutbing/Nttiw Residential: # of Water Closctu _ Plumbing Repair - Residential or Commercial Occupancy Typd: Residential Commercial ,i<" Industrial Colistructioa Type:i' ,� # of Storivd: , # of Dwelling Units: Flood lona: (FILMA forte required) br't f♦ s �„% �^ 5jnr S Owners Name & Addrees t`1�7 C.. L71U , �, -G.f Phone: C1tractor Natw & Adttress: tr�lOra S i li.V �Zi r.� t Z.L . 'SN 'i dri �n.lrtc 4 1, l3o ugC9 -��rs Addresi: Ap- � Mortgage Leader: Address: ArchitectJEn�taear. �T`rC�_r�'^"'t State kense Nutuber. Contact Peravn: / D A" ? 6 -? A e "// 'a7 97LF- `/3,0,0 Address: 15741 A) , C!JfP.c�-►w». —� ofe--. L.� f7+E . l 22 Rax: C1d'y �, `1 9,� - 7 :>-2 3 "TiSd a-4 , "'�'L SS Application ie hereby made to obtain a partnit to do the work and installations AS indicated. I certify that no work or installation has eonwvncod prior to the iasuanoe ofa pormit and tint all work will be pc4onited to maul stundords of till laws rogalating construction in this jurisdiction. I understand dist a supsratt: permit trust be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFTISAVI'l': J certify that all of tho foroguinb information is accuive and that all work will be dome in contpli4mc with all applicable laws rogulatinb coanstruction and Wiling, WARNING TO OWNER: YOUR FAILURS TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. If YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTi F.: Jn addition to the requirements of this permit, there may W additional tretrictions applicable to this property that may be found in the public records of this county, and thorn may be additional permits required from other sovenrtncntal untities such as water ri anagement districts, state agencies, orfc&tal agoneius. Acceptance of Nnrat is vat' kation that i will notify the.", of the propatty of the requirep4sofFloid.Li a , FS 713, i Cie-cv � �JZ?toy �J.s►>.� IN Print // OtPRY P�BIi 0. R. SHOOK, JR. ( } * * MY COMMISSION # DD 170406 EXPIRES: December 26, 2006 �/` Owaer/Ascnt is Personally Know�t' °e Bonded Thru Budget Notary SN`''caConttaCtttdAsertt is ` perstmally Known to Mo or —Produced IP _A- Proitasod ID APPROVALS: ZONING: UTIL: Special Conditions: Rev 0312006 ZO/Z0 39dd Nonon21SSN00 0Id2100S STV89GZ609T A. '/. �+ • !`GAJ,' �9 �\ 6Z:T0 90OZ/LZ/90• 'i .A0 Q�- aq4T3(a IMPROVE. P CONp1T10 ENS MAg THINTHE _ EXENSlCS SrING ONDITIOLL Be S SHA N wFl ED gy TWE rE MI3EI ALL EXIS ES OR RE S SHALL SNAN" F TING aNgNTMAYREUSBpN3113IL171E NOTRELIE ' AIIURETpyERIFY LANDLORD. OR770/yg SRESUL77NGFR ONgNTOFANy IMPROVE PRIOR S PRIOR WRITT OF EXISTING 1MPR M THA T FAILURE . AND WORKING O SHALL BE CLEAR Y INDi I. REUSE OMENS SUBJECT REPRESENT R4WNGS, lY1NpICATED EOFONNEXISTING IMPROSMENTS EUSED BY a CON N ASro O77ON OR SU0 MAKES N ABI RR N Y OLAYOUT SN USING ANY gIID R SYSTEMS WILL AND ALL A IS-noy SYSTEM$ FIE OF EXISTING CHANGES AND UPG AND ACCOMMODATE eO SR1Fy THAT OHTRAC OR1A. ALL Upr,RADE3L BE CppE COM APPLlCgT10N3. .'FAT ISI AT 7ENANr3 EXPENSE. BE SMALL PERFO MED By ME67' MgTH ANY PAINT IN TIME, A FAILURE AN EXISTING gy TENgNT3 RESPONSIBILIT OM SHOULD OCCUOPUPGRADC&IMPWPROVEMEROV .TENAN7•SA N7*3AS EQUI ED,INANCIM ES STEMpR TSSOLEN7STO CO 11CA770 MEO1A TE OR U�RgpES/ TIONS NTE F OF THE SHALL Ivor 1 USAGE Op EXIS7IN MALL'S SYSTEMS, OR NAT OF S COMDR OMIS E INTEn TDY NANTS. TENANT IS REQUIRED TO MAKE A FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE AND IS RESPONSIBLE FOR MAKING ANY AND / OR ALL MODIFICATIONS REQUIRED TO INSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED THE ELECTRICAL SERVICE. APPROVAL OF TENANT'S CONSTRUCTION DOCUMENTS APD SPECIFICATIONS BY THE LANDLORD _N I`RELEASE THE TENANT OR THE TENANT'S CONTRACTOR FROM COMPLYING WITH THE LEASE AGREEMENT AND ALL APPLICABLE BUILDING CODES AND GOVERNING REGULATIONS. UQIWM IS PEq>;, TTED 0 BE ATTACHED i V, OR SUSPENDED FROM, .OR PENETRATE, THE ROOF DECK ABOVE. YOU ARE REQUIRED TO FRAME, BRACE AND / OR SUSPEND, AS NEEDED, TO / FROM THE TOP CHORD OF JOISTS OR STRUCTURAL STEEL WHICH EXIST ABOVE YOUR RESPECTIVE TENANT SPACE: THE TENANT SHALL BE RESPONSIBLE FOR VERIFYING THAT THESE REMODEL/CONSTRUCTION DOCUMENTS MEET ALL A.D.A. STANDARDS OR REQUIREMENTS PROJECT LOCATION _ ®Y�ST•a:- . 6�11�,76iiN11�I`'�i �{y(:;.A �F� � i� T , ti+ �.ryp�}Rp` i ,^ `^ i, r1l jt Ao�ffY�,rp'fx s ✓Yci�e,(�Ia�3S sr��'`5 �2 i•.,rcgs �f. SF4d���g5W}gI+` K{ .. i r• Lake /�ottiroe4h,.yx��,�J+� i 'Y; SENMOLE ICWM AVC TOWNE QS N a. „..Aw J O CENTER % r 8• 11 7r � r >� 46�r a s 4S KT 'J, t4? IMP as ks n Ir .£ <: '� Wlkan bhra<r� o, � iQ ' i r' 1 ,•. y a I t r E s> 5 rri' S �•, i• r S' 1� J !1. L}t j ` : c: t t�' eIaCACfatYu+ Iro ':57 i- '+ 2. PROJECT DESCRIPTION: ................. INTERIOR RETAIL REMODEL 3. PROJECT LOCATION:.................... SEMINOLE TOWNE CENTER O 200 TOWNE CENTER CIRCLE SPACE NO. E08A 1 i Tang(e '��71 rl Markaro tdCrkhami�dW.ithetn ft p<• 3450 EAST MIRALOMA AVENUE ANAHEIM, CALIFORNIA cI2506-2101 o o ('714) 414-4000 KIM BENNETT kbennett®poe-ificsunweor.com & LANDLORD: ............................... SIMON PROPERTY GROUP O 3 I i F t•: �� . �' r'^ Ml i 1j Y.:. d` 't� J i��,;i � :I` 1�•t+/•!11• 1 �' �'fv"ZjrS tsK (� ���,,r { � 1 .j^. CONTACT: DAVID FLETCHER M = O + F IJ 6. TENANT'S ARCHITECT: .................. •�4t� r � 1 t 1 1 t r J � ',,. 1 '��' t i t CYuf� ii i, 'i i t *� ,< � c, _ 15425 NORTH 6REENAAY-HAYDEN LOOP, SUITE #100 T[ SCOTTSDALE, ARIZONA 85260 ��� � 4 5 f iv (480) 11418-4200 FAX: (602) 11415-1228 7. GOVERNING CODES. .. . .................. ALL WORK SHALL BE IN CONFORMANCE AITH, BUT NOT LIMITED TO, THE REQUIREMENTS OF THE FOLLOWING: AND ANY OTHER STATE AND LOCAL CODES HAYING JURISDICTION. BUILDING: 2004 FLORIDA 5UILDIN6 CODE ...1,QROo5NAy,Vt VICINITY MAP SANFORD FL N.T.S. Lower Level F ' 73. F t;a is 1 re �l KEY PLAN SEMINOLE TOWNE CENTER N.T.S. !1,11761� , i❑ C EMINOLE TOWNE CENT 200 TOWNE CENTER C SPACE NO. E08 SANFORD, FL 32771 PROJECT DATA \ CLE 1. PROJECT NAME....... D.E.M.O. . . ... . ........ . .. . . 2. PROJECT DESCRIPTION: ................. INTERIOR RETAIL REMODEL 3. PROJECT LOCATION:.................... SEMINOLE TOWNE CENTER O 200 TOWNE CENTER CIRCLE SPACE NO. E08A SANFORD, FL 32111 4. TENANT:....... ........................... D.E.M.O. 3450 EAST MIRALOMA AVENUE ANAHEIM, CALIFORNIA cI2506-2101 o o ('714) 414-4000 KIM BENNETT kbennett®poe-ificsunweor.com & LANDLORD: ............................... SIMON PROPERTY GROUP O 115 A. WASHINGTON ST. INDIANAPOLIS, IN 46204 CONTACT: DAVID FLETCHER M = O + PH: (311) 263-228'1 6. TENANT'S ARCHITECT: .................. FITCH 15425 NORTH 6REENAAY-HAYDEN LOOP, SUITE #100 00 SCOTTSDALE, ARIZONA 85260 (480) 11418-4200 FAX: (602) 11415-1228 7. GOVERNING CODES. .. . .................. ALL WORK SHALL BE IN CONFORMANCE AITH, BUT NOT LIMITED TO, THE REQUIREMENTS OF THE FOLLOWING: AND ANY OTHER STATE AND LOCAL CODES HAYING JURISDICTION. BUILDING: 2004 FLORIDA 5UILDIN6 CODE 00 V MECHANICAL: 2004 FLORIDA BUILDING CODE PLUMBING: 2004 FLORIDA BUILDIN6 CODE ELECTRICAL: 2004 NATIONAL ELECTRIC CODE HANDICAP: ADAA6 FIRE: 2004 FLORIDA FIRE PREVENTION CODE ENERGY: 2004 FLORIDA BUILDIN6 CODE 8. CONSTRUCTION TYPE: .................. II B, (FULLY SPRINKLERED) 9. OCCUPANCY:.... ......................... (M) MERCANTILE 10. GROSS LEASED PREMISES: ........ ..... s,000 S.F. 11. OCCUPANT LOAD; , , , , , , , , , , , , , , , , , , , , , ,, TOTAL NUMBER OF OCCUPANTS = 60 TOTAL NUMBER OF EMPLOYEES AT ONE TIME = 3 PUBLIC AREA: 2,2416 S.F. 30 = 1-1 NON PUBLIC AREA: T04 S.F. _ BOO = 3 12. EXIT REQUIREMENTS: ..... . . . .. . . . . . . . . . TAO (2) EXITS REQ., TWO (2) EXITS PROVIDED 13. EXIT ILLUMINATION:_ . ........ . . . . . .. . . . EMER6ENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHORN ON SHEET E2. 14. MUNICIPAL REVIEW:........ ............. CITY OF SANFORD 300 NORTH PARK AVENUE P.O. BOX 11756 SANFORD, FL 32111 CONTACT: GARY AINN PHONE: (40-1) 330-5656 15. MISCELLANEOUS NOTES: , . , , ...... , . , .. TENANT'S GENERAL CONTRACTOR SHALL V1517 THE PREMISES AND VERIFY ALL EXIST— IN6 CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DIS— CREPANCIES TO TENANT'S ARCHITECT, TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS RE6ARD— _ IN6 CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE LANDLORD. 16. FIRE SPRINKLER NOTE; , ,, , , , , , , , , , , , , , ,, AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTIN6 WITHIN THIS SPACE. THE CONTRACTOR SHALL REWORK AND MODIFY FOR NEW ROOM LAYOUT AND CEILING HEI6HTS IN CONFORMANCE WITH N.F.P,A. 13 STANDARDS AND LOCAL CODES & RE6ULATIONS. ALL WORK SHALL BE DONE BY A QUALIFIED SPRINKLER CONTRACTOR WHO SHALL DESIGN AND PREPARE SHOP DRAAIN6S AND SUBMIT THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALL- C .c ATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. HEADS TO BE SEMI - RECESSED WHEN IN CEILING TILES. SURFACES, USE STANDARD HEADS IN OPEN CEILING CONDITIONS. CENTER SPRINKLER HEADS IN CENTER OF TILE AHEM USED. SPRINKLER P O HEADS MUST BE CONCEALED TYPE IN THE DRYAALL CEILING. f ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ .■ ■■ ■ ■■ ■ . ■ Simon Property Group requires all ' tenants to use SimplexGrinnell for : ■ all sprinkler work. ■ At the time of bidding, each tenant or : ■ tenant general contractor should call ■ SimplexGrinnell's National Accounts ■ Representative to obtain direction for ■ ■ pricing and scheduling @ 800-299-4377 ■ (Option #1, ext. 8488) : Tenant or Tenant's General Contractor is ■ required to contract with (and pay for) all tenant sprinkler work directly with ■ ■ SimplexGrinnell. ■ ■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■r SPRINKLER SYSETEM MODIFICATIONS MUST BE PERFORMED BY THE MALLS DESIGNATED SPRINKLER CONTRACTOR SIMPLEX GRINNELL AT THE TENANTS EXPENSE AND SUBMITTED TO LANDLORDS CIONSULTANT GLOBAL RISK CONSULTAN'T'S FOR REVIEW." " INDEX OF DRAWIWdas T TITLE SHEET SP1 SPECIFICATIONS SP2 SPECIFICATIONS, &FINISH SCHEDULE SP3 RESPONSIBILITY SCHEDULE D7 DEMOLITION PLAN Al DIMENSIONED FLOOR PLAN A2 FIXTURE PLAN A2.1 FLOOR FINISH PLAN A3 REFLECTED CEILING PLAN A4 STOREFRONT ELEVATION AS STOREFRONT SECTIONS & DETAILS AS INTERIOR ELEVATIONS A6.1 INTERIOR ELEVATIONS A7 SECTIONS AND DETAILS Jut A8 SECTIONS AND DETAILS A9 SECTIONS AND DETAILS N11 _MECHANICAL PLAN M2 MECHANICAL SCHEDULES, DETAILS &SPECS. P1 I PLUMBING FLOOR PLAN E1 ELECTRICAL LIGHTING PLAN 6 E2 ELECTRICAL POWER PLAN SCI E3 PANEL SCHEDULES, RISER DIAGRAM, NOTES & SPEMP Fire 2246 COPYRIGHT NOTIM These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. '� �IVi■ � V • V i- e— H Ou C C 3:°'00M —Q O V oW ■ LLM Co -- 3 z 00 .= v O E o � = u. Z 0 an M 0 ,.to N W to V 0 cc W W Z Z LLIZ J W � D oZj Z Q F-� Q W � X� JA W W � J 0 H � F= a VII 0 0 0 O •� m L/1 N CL N r- o o rn O 3., M = O + ' tQ U_ N 00 M 00 V 00) o C ppU, Ln Ct a a 1A _ _^ C .c ;i P O a / ' JlJN 6 '06 DATE: 6/1/06 SHEET: SCALE: NONE DRAWN BY: J00 PROJECT No.: DEM06024 DIVISION 1 - GENERAL REQUIREMENTS 1. THE WORK INCLUDES NEW TENANT IMPROVEMENTS IN AN EXISTING MALL SPACE, PER SQUARE FOOT CALCULATIONS AS NOTED ON THE TITLE SHEET. CONTRACT WILL INCLUDE CONSTRUC- TING WALLS AND CEILINGS & FLOOR PER "D.E.M.O." STANDARD FINISHES, DETAILS & SPECIFICATIONS. SECURE AND PAY FOR GOVERNMENT FEES, LICENSES, AND PERMITS. 2. CONTRACTORS SHALL VISIT THE PREMISES WHILE BIDDING AND SHALL FAMILIARIZE THEM- SELVES WITH EXISTING CONDITIONS AND THE REQUIREMENTS OF THE PROJECT PRIOR TO DEVELOPING THEIR BID. MATERIAL QUANTITIES SHALL BE BASED ON ACTUAL FIELD CONDITIONS AND MEASUREMENTS. DO NOT RELY ON SCALING PLANS FOR ACCURATE DIMENSIONING. 3. PRIOR TO BEGINNING THE WORK, VERIFY ALL EXISTING DIMENSIONS AND SQUARE FOOTAGES. NOTIFY THE OWNER OF COMPLIANCE OR DISCREPANCIES, COMPARING THOSE DISCREPANCIES TO THE NUMBERS ON THE TITLE SHEET. 4. CONTRACTORS SHALL TAKE CARE TO PROTECT ADJACENT AREAS FROM DUST AND DAMAGE DURING THE CONSTRUCTION PROCESS, AND SHALL CLEAN UP AFTER THEMSELVES AT THE END OF EACH WORKING DAY. 5. ALL RUBBISH AND TRASH SHALL BE REMOVED FROM THE PREMISES AND PROPERLY DISPOSED OF EACH DAY. NO RUBBISH SHALL BE LEFT IN THE PREMISES AFTER WORK IS COMPLETED EACH DAY. 6. ALL DRAWINGS HEREIN CREATE AN ENTIRE PACKAGE. ALL TRADES SHALL BE RESPONSIBLE FOR REVIEWING THEIR RESPECTIVE REQUIREMENTS AND COORDINATING THEIR HIDDEN OR EX- POSED WORK WITH OTHER RELATED TRADES. 7. COORDINATE ALL WORK OF THE VARIOUS TRADES AND SUBCONTRACTORS TO ASSURE EFFI- CIENT AND ORDERLY INSTALLATION. PROVIDE ACCOMMODATION FOR ITEMS INSTALLED AT A LATER DATE. VERIFY THAT CHARACTERISTICS OF ELEMENTS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK OF VARIOUS SECTIONS WHICH HAVE INTERDE- PENDANT RESPONSIBILITIES FOR INSTALLING, CONNECTING TO, AND PLACING IN SERVICE, SUCH EQUIPMENT. COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK AND FIRE SPRINKLER SYSTEM WHICH ARE INDICATED, DETAILED, OR IMPLIED DIAGRAMMATICALLY ON DRAWINGS. 8. UNLESS SPECIFICALLY NOTED, PROVIDE AND PAY FOR LABOR, MATERIALS AND EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK, INCLUDING PERMITS. UTILITIES SHALL BE PROVIDED BY OWNER. 9. GENERAL CONTRACTOR SHALL PURCHASE AND MAINTAIN INSURANCE COVERAGE IN ACCOR- DANCE WITH THE REQUIREMENTS OF THE LANDLORD AND THE TENANT. VERIFY AND COOR- DINATE WITH THE TENANT'S PROJECT MANAGER, ANY ADDITIONAL REQUIREMENTS. 10. FURNISH ALL REQUIRED TEMPORARY FACILITIES AND ALL TEMPORARY UTILITIES IMMEDIATELY AFTER RECEIPT OF NOTICE TO PROCEED FOR USE IN CONVENIENCE OF ALL THOSE ENGAGED IN THE PROJECT WORK. 11. ALL CONTRACTORS MUST STAY BEHIND THE BARRIERS AND MAINTAIN ACCESS TO SUCH AREAS CLEAN AND FREE OF CONSTRUCTION MATERIALS AND DEBRIS. FAILURE TO MAINTAIN CLEAN STOREFRONT WILL RESULT IN BUILDING MANAGEMENT HAVING SUCH MATERIALS AND DEBRIS REMOVED AND ALL CHARGES FOR MAINTENANCE WILL BE BILLED TO GENERAL CONTRACTOR. 12. COORDINATE ALL CONSTRUCTION & SCHEDULING WITH THE BUILDING MANAGER REVIEWING ALL SCHEDULED ACTIVITIES AT OUTSET OF CONSTRUCTION: 13. ALLOWABLE TOLERANCES- UNLESS OTHERWISE NOTED OR INDICATED, THE FOLLOWING TOLER- ANCES LER- ANCES SHALL APPLY TO ALL WORK: a. ALL VERTICAL SURFACES SHALL BE PLUMB OR CONSTRUCTED TO THE EXACT SLOPES OR ANGLES INDICATED. b. THE MAXIMUM DEVIATION FROM THE TRUE PLANE FOR VERTICAL AND HORIZONTAL SURFACES SHALL NOT BE GREATER THAN 1/8" IN 10'-0" AS MEASURED BY A STRAIGHT EDGE PLACED ANYWHERE ON THE SURFACE. c. ALL HORIZONTAL SURFACES SHALL BE LEVEL OR CONSTRUCTED TO THE EXACT ANGLE INDICATED OR INTENDED. d. WALL AND SOFFIT INTERSECTIONS SHALL BE 900 OR THE EXACT ANGLE INDICATED OR INTENDED. e. ALL CORNERS AND EDGES SHALL BE STRAIGHT AND TRUE WITHOUT DENTS, WAVES OR BULGES OR OTHER BLEMISHES. f. ALL JOINTS SHALL BE TIGHT, STRAIGHT, EVEN AND SMOOTH. g. ALL OPERABLE ITEMS SHALL OPERATE SMOOTHLY WITHOUT STICKING OR BINDING AND WITHOUT EXCESSIVE "PLAY" OR LOOSENESS. 14. THE FOLLOWING MATERIALS SHALL BE LEFT AT JOBSITE. THEY SHALL BE TAKEN FROM THE SAME MATERIAL, LOT OR RUN USED TO CONSTRUCT AND FINISH THE PROJECT: a. FOUR FULL LENGTH STRIPS OF RUBBER BASE. b. 1 QUART OF EACH COLOR PAINT IN A TIGHTLY SEALED AND MARKED CAN. MATERIALS SHALL BE LEFT IN ONE LOCATION UPON OWNER'S REPRESENTATIVE'S DIRECTION AND APPROVAL. 15, THE OWNER OR THE OWNER'S SUBCONTRACTORS MAY OCCUPY PORTIONS OF THE PROJECT DURING THE FINAL STAGE OF CONSTRUCTION. COORDINATE AND COOPERATE WITH THE OWNER TO MINIMIZE CONFLICT AND FACILITATE THE OWNER'S OPERATION. 16. ALL DIMENSIONS AND FINISHES SHALL BE VERIFIED AND COORDINATED WITH EXISTING CON- DITIONS PRIOR TO CONSTRUCTION, FABRICATION, OR PURCHASING. IN CASE OF CONFLICT BE- TWEEN THE PROJECT REQUIREMENTS AND/OR EXISTING CONDITIONS, THE ONE HAVING THE MOST STRINGENT REQUIREMENTS SHALL GOVERN, AS APPROVED BY THE OWNER. 17. PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTABLE TRADE PRACTICE TO INSURE THE HIGHEST QUALITY FINISHED PRODUCT - EXPRESSED OR IMPLIED. PERFORM ALL WORK BY SKIL- LED MECHANICS IN ACCORDANCE WITH ESTABLISHED STANDARDS OF WORKMANSHIP IN EACH OF THE VARIOUS TRADES. 18. COORDINATE BLOCKING REQUIREMENTS WITH ADJACENT OR RELATED TRADES, ACCESSORIES, EQUIPMENT & FIXTURES INSTALL REQUIRED BLOCKING AT NO ADDITIONAL COST TO THE CONTRACT. 19. REPAIR PROPERTY DAMAGE BY THE INSTALLERS TO A LIKE NEW CONDITION OR REPLACE DAMAGED SURFACES AND MATERIALS OF THE PREVIOUSLY INSTALLED WORK BY OTHER TRADES, INSTALLERS AND SUBCONTRACTORS. 20. WHERE REQUESTED BY THE OWNER TO CERTIFY CONFORMANCE TO TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL ENLIST A TESTING LABORATORY AT THE OWNER'S COST. IF THE REQUESTED TEST SHOWS NON-CONFORMANCE TO GENERALLY ACCEPTED TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL CORRECT THE DE- FICIENCY AT NO ADDITIONAL COSTS TO THE OWNER AND REIMBURSE ALL THE COSTS OF THE TESTING TO THE OWNER, UNLESS THE CONTRACTOR HAS USED PRODUCTS INCORRECTLY LABELED BY THE MANUFACTURER OR HAS MADE PREVIOUSLY APPROVED CHANGES. 21. PROVIDE SECURITY OF THE WORK, INCLUDING TOOLS AND UNINSTALLED MATERIALS. PROTECT THE WORK, STORED PRODUCTS, CONSTRUCTION EQUIPMENT AND OWNER'S PROPERTY FROM THEFT AND VANDALISM AND THE PREMISES FROM ENTRY BY UNAUTHORIZED PERSONNEL UNTIL FINAL ACCEPTANCE BY OWNER. 22. MAINTAIN AN ACTIVE FIRE EXTINGUISHER AT THE PROJECT. 23. DO NOT USE MATERIAL OR EQUIPMENT FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SPECIFICALLY DESIGNED OR SPECIFIED. ALL MATERIALS AND EQUIPMENT THAT ARE SIMILAR SHALL BE THE SAME TYPE, MODEL, AND STYLE FOR THE SAME USE THROUGHOUT THE PRO- JECT OR THEY SHALL BE REJECTED. 24, WHEN THE PROJECT REQUIREMENTS REQUIRE THAT THE INSTALLATION OF WORK SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS, PERFORM THE WORK IN STRICT ACCORDANCE WITH THE MOST CURRENT WRITTEN MANUFACTURER'S INSTRUCTIONS. 25. ALL PRODUCTS AND EQUIPMENT SHALL BE DELIVERED IN UNDAMAGED CONDITION AND STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS TO AVOID DISRUPTION OF THE WORK OR DAMAGE TO THE ITEMS. REPLACE DAMAGED OR UNFIT MATERIALS, AT NO COST TO THE OWNER. 26, NOTIFY THE OWNER WHEN THE WORK IS SUBSTANTIALLY COMPLETE AND READY FOR FOR IN- SPECTION. UPON INSPECTION, PROVIDE WRITTEN OPERATION AND MAINTENANCE INSTRUCTIONS AND GUARANTEES FOR ALL EQUIPMENT AND MATERIALS INSTALLED, PROVIDE WRITTEN GUAR- ANTEES FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK. 27. PROVIDE FINAL CLEAN-UP AND DAMAGE REPAIR AT THE PROJECT CONCLUSION, LEAVE THE PREMISES NEAT, CLEAN AND CLEAR OF TOOLS, EQUIPMENT AND SURPLUS MATERIALS, UN- LESS REQUESTED BY THE OWNER. CLEAN-UP SHALL INCLUDE AND NOT BE LIMITED TO: a. POWER VACUUMING THE ENTIRE SPACE. b. HAND DUSTING AND CLEANING OF ALL SHELVING, CABINETRY, CASEWORK, GLASS AND MIRRORS BOTH INSTALLED UNDER THIS CONTRACT OR EXISTING WALLS, CEILINGS, FIXTURES, ETC. c. REPAIR OR REPLACEMENT OF PROPERTY DAMAGED DURING FINAL COMPLETION OF THE PROJECT. SPECIFICATIONS DIVISION 2 - DEMOLITION / BUILDING ALTERATIONS 1. THE WORK MAY INCLUDE DEMOLITION OF EXISTING CONSTRUCTION, REMOVAL OF VARIOUS ITEMS OF EQUIPMENT AND CONSTRUCTION, AND THE CUTTING OR ALTERATION OF EXISTING CONSTRUCTION AS SHOWN, NOTED OR IMPLIED ON THE DRAWINGS. CONTRACTOR SHALL DE- TERMINE AND INVENTORY ALL NECESSARY DEMOLITION AND ALTERATION OF ITEMS TO PRO- VIDE FOR A COMPLETE INSTALLATION OF NEW WORK. ALL COSTS OF REMOVAL, REPAIR OR REPLACEMENT SHALL BE INCLUDED IN THE BID. ADDITIONAL COSTS FOR DEMOLITION OF ITEMS HIDDEN OR INACCESSIBLE DURING THE BIDDING PHASE, SHALL BE SUBMITTED FOR APPROVAL PRIOR TO BEGINNING THE WORK. 2. AT ALTERED CONSTRUCTION, REPAIR CUT EDGES, REPLACE CONSTRUCTION, AND FIT NEW TO EXISTING CONSTRUCTION TO MATCH EXISTING WORK. MAKE JOINTS OF NEW AND EXISTING PATCHES VERY SMOOTH, EVEN AND PRACTICALLY INVISIBLE. COORDINATE ALL REPLACEMENT AND REPAIR REQUIREMENTS WITH LANDLORD'S CONSTRUCTION CRITERIA AND TENANT'S CO- ORDINATOR. 3. SAW -CUT CONCRETE WITH DIAMOND SAW; JACKHAMMERING WILL NOT BE PERMITTED EXCEPT WITH THE EXPRESSED WRITTEN APPROVAL OF THE LANDLORD. CUT IN ACCURATELY LOCATED, STRAIGHT LINES, AND BREAK OUT SECTIONS. FLOOR MAY BE CORE DRILLED WHERE APPROPRIATE FOR INSTALLATION OF PIPES AND SIMILAR ITEMS. COORDINATE ALL CORE LOCATIONS AND SLAB MODIFICATIONS WITH LANDLORD'S STRUCTURAL ENGINEER. WHERE EXISTING PIPING AND OTHER SIMILAR ITEMS ARE UNDER EXISTING SLABS, EXERCISE CARE TO PROTECT FROM DAMAGE, EXERCISE CARE WHEN CUTTING ADJACENT TO EXISTING WALLS TO AVOID DAMAGE TO WALLS. IF DAMAGED, REPAIR AS REQUIRED TO ORIGINAL CONDITION. 4. DOORS & FRAMES: IF DOORS AND FRAMES ARE TO BE REUSED ON THE WORK, CAREFULLY REMOVE DOOR FROM FRAMES AND REMOVE FRAMES FROM OPENING, TAKING CARE TO AVOID DAMAGE. REMOVE HARDWARE, CLEAN, REFURBISH, AND STORE FOR REINSTALLATION WHERE INDICATED. FOR DOORS AND FRAMES TO BE SALVAGED, CAREFULLY REMOVE FROM OPENING AND DELIVER FOR STORAGE WHERE INDICATED. 5. PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE. PROVIDE AND PLACE BRACING AND SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE, AS DETERMINED BY G.C. ENLISTED STRUCTURAL ENGINEER, ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT DAMAGE OR INJURY. 6. ARRANGE AND PAY FOR DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREAS AFFECTED BY DEMOLITION. PLACE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. LOCATE SPRINKLER SHUT-OFF VALVE AND SMOKE ALARM PRIOR TO COMMENCING WORK; COORDINATE REQUIRED MODIFICATION WITH LANDLORD. 7. CAREFULLY REMOVE MATERIALS AND EQUIPMENT WHICH ARE INTENDED TO BE REUSED. STORE IN A SECURE LOCATION. REMOVE DEBRIS, REFUSE AND MATERIALS BEING DEMOLISHED IM- MEDIATELY FROM THE SITE. 8. ERECT AND MAINTAIN WEATHERPROOF AND DUSTPROOF CLOSURESS AND PARTITIONS TO PRE- VENT WEATHER DAMAGE OR SPREAD OF DUST, FUMES AND SMOKE TO OTHER PARTS OF THE BUILDING, IN ACCORDANCE WITH MALL GUIDELINES AND STIPULATIONS. 9. PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION. 10. REPAIR ALL DEMOLITION IN EXCESS OF THAT REQUIRED AT NO COST TO THE OWNER. 11. REMOVE FROM SITE CONTAMINATED, VERMIN INFESTED OR DANGEROUS MATERIALS ENCOUNTERED; DISPOSE OF BY SAFE MEANS TO PROTECT HEALTH OF WORKERS AND PUBLIC. DIVISION 3 - CONCRETE REPAIR & REPLACEMENT 1. WORK INCLUDES PATCHED, DEMOLISHED SLAB AND CERAMIC TILE, IF ANY; FILLING AND LEVELING JOINTS AND CRACKS; AND FILLING ABANDONED ELECTRICAL BOXES AND ANY HOLES GREATER THAN 1/2". 2. USE RAECO-LITH "R-35" AS UNDERLAYMENT FOR PATCHING OR APPROVED EQUAL. MIX SHALL BE TWO PARTS - MORTAR MIX AND LATEX BINDER. MIX AND INSTALL PER MANU- FACTURER'S LATEST WRITTEN AND RECOMMENDED DIRECTIONS. SELF LEVELMG CONCRETE FLOOR TOPPING I. GENERAL A. DESCRIPTION 1. PROVIDE A PORTLAND CEMENT -BASED, SELF -DRYING, SELF -LEVELING CEMENTITIOUS TOPPING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 2. PROVIDE LABOR, MATERIAL, EQUIPMENT, AND SERVICES NECESSARY TO COMPLETE THE CEMENTITIOUS TOPPING WORK AS HEREIN SPECIFIED. 3. THIS SYSTEM CONSISTS OF A PRIMER AND A MIX OF SPECIAL CEMENTS AND BINDERS WHICH, WHEN MIXED WITH WATER, BECOMES A LIQUID CEMENT COMPOUND THAT DRIES WITHIN ITSELF, SEEKS ITS OWN LEVEL, AND PRODUCES A FLAT, SMOOTH SURFACE. SURFACE SHALL BE TRUE TO PLANE WITHIN 1/4" MAXIMUM DEVIATION UNDER A 10' STRAIGHT EDGE IN ACCORDANCE WITH ACI 302 1R-89, FLATNESS TOLERANCE. B. QUALIFICATIONS 1. INSTALLATION OF THE CEMENT -BASED, SELF -DRYING, SELF -LEVELING TOPPING MUST BE BY AN APPLICATOR USING MIXING EQUIPMENT AND TOOLS APPROVED BY THE MANUFACTURER. 2. PROVIDE ARDEX SD -T SELF -DRYING, SELF -LEVELING CONCRETE TOPPING AS MANUFACTURED BY ARDEX INC., 1155 STOOPS FERRY ROAD, CORAOPOL.IS, PA 15108. A. TOPPING SHALL BE ABLE TO BE INSTALLED FROM 1/4" TO 2" IN ONE POUR, BUT MAY BE TAPERED TO MATCH THE EXISTING ELEVATION. B. TOPPING TO BE APPLIED TO A MINIMUM THICKNESS OF 1/4" OVER HIGHEST POINT IN THE SUBFLOOR C. TOPPING MATERIAL SHALL ACHIEVE COMPRESSIVE STRENGTH OF 6100 PSI AFTER 28 DAYS PER ASTM C109 MOD. D. TOPPING SHALL BE WALKABLE AFTER 2-3 HOURS AT 70oF, AND BE ABLE TO BE SEALED WITH A WATERBORNE COATING AS SOON AS IT CAN BE WORKED ON WITHOUT DAMAGE. C. APPLICATIONS 1. AFTER PROPER PREPARATION, TOPPING SHALL BE SUITABLE OVER NEW OR OLD INDOOR CONCRETE: UNFINISHED, ROUGH, RAINED -ON, FROZEN, SPALLED OR OTHERWISE DETERIORATED CONCRETE. D. DELIVERY, STORAGE AND HANDLING - DELIVER MATERIALS IN THEIR UNOPENED PACKAGES AND PROTECT FROM EXTREME TEMPERATURES AND MOISTURE. PROTECT LIQUIDS FROM FREEZING. II. PRODUCTS A. MATERIALS 1. THE CEMENT -BASED, SELF -DRYING, SELF -LEVELING TOPPING SHALL BE ARDEX SD -T SELF DRYING, SELF -LEVELING CONCRETE TOPPING. 2. PRIMER FOR STANDARD ABSORBENT CONCRETE SHALL BE ARDEX P-51 PRIMER. 3. WATER SHALL BE CLEAN, POTABLE, AND SUFFICIENTLY COOL (NOT WARMER THAN 70oF). 4. WEAR SURFACE: THE FINISHED SD -T SURFACE CAN BE COATED WITH A WATERBORNE SEALER 2-3 HOURS AFTER INSTALLATION, B. TECHNICAL DATA - BASED ON A MIXING RATIO OF 4 PARTS POWDER TO 1 PART WATER (PBV). FLOWING TIME: APPROX. 10 MINUTES AT 70oF INITIAL SET, ASTM C191: APPROX. 15 MINUTES AT 70oF FINAL SET, ASTM C191: APPROX. 60 MINUTES AT 70oF COMPRESSIVE STRENGTH; ASTM C109/MOD: APPROX. 6100 PSI AFTER 28 DAYS FLAMMABILITY, ASTM E84: FLAME SPREAD -0- FUEL CONTRIBUTION -0- SMOKE DEVELOPMENT -0- COVERAGE, 50 LB. BAG: APPROX, 25 SQ. FT. AT 1/4" III. EXECUTION IN ADDITION TO THE GENERAL PROCEDURES DESCRIBED HEREIN, REFER TO THE MANUFACTURER'S CURRENT PUBLISHED PRODUCT LITERATURE FOR COMPLETE INSTALLATION DETAILS FOR THE MATERIAL BEING INSTALLED, A. PREPARATION 1. ALL STANDARD ABSORBENT CONCRETE SURFACES MUST BE SOUND, SOLID, CLEANED, AND PRIMED. DIVISION 4 - NOT USED DIVISION S - METAL FABRICATIONS 1. PROVIDE ALL MISCELLANEOUS METAL ITEMS INCLUDING MATERIALS, FABRICATIONS, FASTEN- INGS, AND ACCESSORIES REQUIRED FOR FINISHED INSTALLATION AS INDICATED AND SPEC- IFIED. 2. STEEL SHALL BE ASTM A366 AMERICAN OPEN HEARTH SHEET STEEL, FREE FROM SCALE AND PITTING AND OTHER DEFECTS AFFECTING APPEARANCE. 3. TUBING SHALL CONFORM TO REQUIREMENTS OF ASTM A500 OR A501 AS APPROVED. 4. WHERE METAL ITEMS ARE TO BE ERECTED AND IN CONTACT WITH DISSIMILAR MATERIALS, PROVIDE CONTACT SURFACES WITH COATING OF AN IMPROVED ZINC CHROMATE PRIMER IN MANNER TO OBTAIN NOT LESS THAN 1.0 MIL DRY FILM THICKNESS. 5. SHEET STEEL SHALL CONFORM TO REQUIREMENTS OF ASTM A606. 6. CARBON STEEL BARS SHALL CONFORM TO REQUIREMENTS OF ASTM A321. 7. ALUMINUM EXTRUSIONS SHALL CONFORM TO ASTM B221. REVEALS TO BE CLEAR ANODIZED FINISH. (UNLESS OTHERWISE NOTED) 8. FASTENERS SHALL BE AS REQUIRED FOR ASSEMBLY AND INSTALLATION OF FABRICATED ITEMS. 9. BOLTS SHALL BE LOW CARBON STEEL EXTERNALLY AND INTERNALLY THREADED FASTENERS CONFORMING WITH REQUIREMENTSF A TM A 7' 0 S 30 INCLUDE NECESSARY NUTS AND PLAIN HARDENED WASHERS. FOR MEMBERS FOR SUPPORT OF STRUCTURAL MEMBERS OR CONNEC- TION THERETO, USE FASTENERS CONFORMING WITH ASTM A325. FOR STAINLESS STEEL AND NON-FERROUS ITEMS, USE TYPE 302 AND 304 STAINLESS STEEL FASTENERS. 10. MISCELLANEOUS MATERIALS: PROVIDE ALL INCIDENTAL ACCESSORY MATERIALS, TOOLS, METHODS, AND EQUIPMENT REQUIRED FOR FABRICATION AND INSTALLATION OF MISCELLAN- EOUS METAL ITEMS AS INDICATED ON DRAWINGS. 11. VERIFY DIMENSIONS PRIOR TO FABRICATION OR CASTING. FORM METAL ITEMS TO ACCURATE SIZES AND CONFIGURATIONS AS INDICATED ON DRAWINGS AND OTHERWISE REQUIRED FOR PROPER INSTALLATION; FABRICATE WITH ALL LINES STRAIGHT AND ANGLES SHARP, CLEAN AND TRUE; DRILL, COUNTERSINK, TAP, AND OTHERWISE PREPARE ITEMS FOR CONNECTION WITH WORK OF OTHER TRADES. MAKE PERMANENT CONNECTIONS BY WELDING AND GRIND ALL EXPOSED WELDS SMOOTH TO MATCH ADJACENT SURFACES; ROUGH JOINT SUR- FACES NOT PERMITTED, AVOID USING BOLTS AND SCREWS UNLESS SPECIFICALLY INDICATED OR APPROVED; WHEN USED, DRAW UP TIGHT AND TIE THREADS TO PREVENT LOOSENING. 12, ALL FERROUS METAL ITEMS SHALL BE SHOP FINISHED. TOUCH-UP OR REPAIR DAMAGED AREAS PRIOR TO INSTALLATION WITH SAME MATERIAL. 13. PROVIDE CONTACT SURFACES WITH CONCRETE MASONRY OR OTHER DISSIMILAR MATERIALS WITH A MINIMUM ONE POINT ZERO (1.0) MIL DRY THICKNESS 0F AN APPROVED ZINC CHRO- MATE MATE PRIMER. 14. PROVIDE ALL STEEL BLOCKING AND BRACING IN METAL STUD FRAMED PARTITIONS NECESSARY FOR A COMPLETE INSTALLATION. INCLUDE AS REQUIRED FOR SUPPORT OF ALL WALL -MOUNTED EQUIPMENT AND FABRICATIONS AS INDICATED ON DRAWINGS. PROVIDE SUPPORTS AT JAMBS OF DOORS AND ELSEWHERE, AS REQUIRED. 15. FABRICATE ALL MISCELLANEOUS FRAMING AND BRACING ITEMS TO DETAIL OF STRUCTURAL SHAPES, PLATES, AND BARS; WELD JOINTS WHERE PRACTICAL; PROVIDE BOLTS AND OTHER CONNECTION DEVICES REQUIRED. INCLUDE ANCHORAGES, CLIP ANGLES, SLEEVES, ANCHOR PLATE, AND SIMILAR DEVICES, WHETHER IMPLIED OR INDICATED. SET ACCURATELY IN POSITION AS REQUIRED AND ANCHOR SECURELY TO BUILDING CONSTRUCTION WITH FAST- ENERS APPROPRIATE TO THE INSTALLATION. DIVISION 6 - WOOD & PLASTICS 1. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS. MOISTURE CONTENT NOT MORE THAN 19%. 2. PROVIDE ALL NECESSARY ROUGH HARDWARE IN SIZES IN QUANTITIES REQUIRED BY LOCAL CODE OR APPROVED BY ARCHITECT. 3. USE FINISH OR CASING NAILS FOR EXPOSED WORK; USE TYPE "S" TRIM HEAD SCREWS FOR ATTACHMENT OR WOOD TRIM TO METAL STUDS, RUNNERS, OR FURRING. 4. RELIEVE BACKS OF WOOD TRIM; KERF BACKS OF MEMBERS MORE THAN 5" WIDE AND 1" NOMINAL THICKNESS; EASE ALL EXTERNAL CORNERS, 5 INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY CONDITION FOR INSTALLATION. 6. USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR APPLICATION; INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOST CURRENT PRINTED APPLICATION IN- STRUCTIONS. 7. PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE INSTALLATION. RE- PLACE DAMAGED SURFACES. 8. REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED SOLVENT AND CLEANING PROCEDURES. 9. FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOUND. 10, INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS, WITH THE FOLLOWING CON- SIDERATIONS AND REQUIREMENTS: a. INSTALL ALL MATERIAL WITH TIGHT JOINTS. b. MITER CASINGS AND MOLDINGS. c. ALL RUNNING TRIM ONE ('1) PIECE UP TO 10'-0". MATCH GRAIN AND COLOR PIECE - TO PIECE. d. USE FINISH NAILS EXCEPT WHERE SCREWS ARE SPECIFICALLY CALLED FOR OR WHERE SCREWS DO NOT SHOW. e. SET FASTENERS FOR PUTTYING. f, WHERE SCREW ATTACHMENT REQUIRED, SPACE SCREWS AT EQUAL INTERVALS; SINK AND PUTTY IN FINISH WOOD SURFACES. g. ALL MEMBERS AND LINES LEVEL AND PLUMB. h. SELECT AND CUT MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS. L FINISH EXPOSED SURFACES SMOOTH, FREE FROM TOOL AND MACHINE MARKS. j. EASE ALL EXPOSED WOOD EDGES 1/8" MINIMUM RADIUS. k. INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS. 11. ALL WOOD SHALL BE FIRE RETARDANT TREATED IN ACCORDANCE WITH I.B.C. SECTION 603.1. DIVISION 7 - SEALANTS AND CAULKING 1. PROVIDE NON -SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL SPECIFICATIONS ASTM C920, TYPE S, GRADE NS. PROVIDE ACOUSTICAL SEALANT WHICH SHALL BE NON -HARDENING, NON-DRYING SYNTHETIC RUBBER SEALING COMPOUND WITH MIN- IMUM 90% SOLIDS. USE AT ALL INTERIOR JOINTS AT INNER SECTIONS BETWEEN PLANES. AROUND DOOR AND WINDOW FRAMES PRIMER SHALL BE MADE OR RECOMMENDED BY SEALANT MANUFACTURER FOR THE SPECIFIC CONDITIONS AND SUBSTRATES. 2. PROVIDE BACKING MATERIAL BY DOW "ETHAFOAM" OR APPROVED EQUAL. APPLY SEALANT OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL JOINTS AND VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT BE ACCEPTED. 3. ALL SURFACES SHALL BE ADEQUATELY CLEANED AND PREPARED IN ACCORDANCE WITH MAN- UFACTURER'S WRITTEN INSTRUCTIONS PRIOR TO INSTALLATION. DIVISION 8 - WOOD & HOLLOW METAL DOORS & FRAMES 1. PROVIDE "TIMELY" KNOCKDOWN DOOR FRAMES AT ALL G.C. PROVIDED DOORS, FREE FROM SCALE AND PITTING AND OTHER SURFACE DEFECTS, UNLESS OTHERWISE NOTED. 2. PROVIDE HOLLOW METAL EXIT DOOR CONSTRUCTED WITH THE FOLLOWING MATERIALS: - MINIMUM 18 GA. FOR FACE SHEETS OF INTERIOR DOORS - 16 GA. FOR EDGE CHANNELS. - MINIMUM 22 GA. FOR FACE STIFFENERS. - MINIMUM 16 GA. FOR INTERIOR FRAMES. 3. PROVIDE DOORS OF SIZES AND TYPES INDICATED ON DRAWINGS, FULLY WELDED SEAMLESS CONSTRUCTION WITH NO VISIBLE SEAMS OR JOINTS ON FACES OR VERTICAL EDGES; THICK- NESSES AS SCHEDULED ON DRAWINGS. 4. FACESTIFFENERS,EDGESAND HARDWARE REINFORCEMENT SHALL BE THE HIGHEST ST HI H QUALITY QU LIT WORKMANSHIP AND MATERIALS. PROVIDE IN ACCORDANCE WITH BEST TRADE PRACTICE AND MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR THE USE INTENDED. 5. PROVIDE CUSTOM MADE WELDED UNITS WITH INTEGRAL TRIM; SIZES AND SHAPES AS INDICATED ON DRAWINGS; FABRICATE UNITS SQUARE, TRUE AND FREE FROM DEFECTS. 6. HARDWARE REINFORCEMENT AND ANCHORS (ERECTION, FLOOR AND JAMB) SHALL BE AS RE- QUIRED FOR A SECURE INSTALLATION AND SHALL BE IN ACCORDANCE WITH TRADE REQUIRE- MENTS FOR THE SPECIFIED HARDWARE AND INTENDED USE. 7. AFTER FABRICATION, DRESS, FILL AND SAND EXPOSED SURFACES, BODY -PUTTY HOLES AND IMPERFECTIONS. APPLY UNIFORM COAT OF MANUFACTURER'S STANDARD PRIME COAT TO ALL EXPOSED SURFACES. LEAVE READY TO RECEIVE FINISH PAINTING. 8. INSTALL FRAMES IN ACCURATE LOCATIONS AS INDICATED ON DRAWINGS. INSTALL RIGID, PLUMB, LEVEL AND TRUE. ALIGN WITH ADJACENT CONSTRUCTION. SECURE FLOOR ANCHORS TO FLOOR CONSTRUCTION WITH APPROVED TYPE MECHANICAL FASTENINGS; ANCHOR TO ADJOINING WALLS WITH SPECIFIED ANCHORS. BRACE FRAMES TO RETAIN POSITION AND CONTINUOUSLY CHECK ALIGNMENT DURING CONSTRUCTION OF ADJACENT WALLS. ADJUST FRAME LOCATIONS AS NE- CESSARY USING SHIMS BEFORE FASTENING. LEAVE READY TO RECEIVE SEALANT WHERE IN- DICATED ON DRAWINGS. 9. INSTALL WOOD DOORS, FRAMES, AND TRIM, SIZES AND THICKNESS AS SCHEDULED ON THE DRAWINGS. 10. PREPARE DOORS FOR FINISH HARDWARE. OBTAIN TEMPLATES FROM HARDWARE MANUFACTURER AND CONFIRM TYPE, LOCATION, AND SPECIAL REQUIREMENTS OF HARDWARE FOR EACH DOOR PRIOR TO CUTTING, 11. HANG DOORS AS SCHEDULED ON DRAWINGS, IN ACCURATE LOCATIONS WITH 1/8" CLEARANCE AT TOPS AND 3/8" CLEARANCE AT BOTTOM, UNLESS SPECIFICALLY NOTED FOR "UNDERCUTS" OR OTHER DEVIATIONS IN FIT. VERIFY CLEARANCES REQUIRED FOR CARPETING AND MAKE NO JOBSITE FIT IN CUTS UNLESS APPROVED. HANG PAIRS OF DOORS AS SPECIFIED WITH 3/32" CLEARANCE AT MEETING EDGES. DEMONSTRATE THAT DOORS OPEN FREELY WITHOUT BINDING, AND WHEN CLOSED, WILL LATCH PROPERLY. 12. ACCESS DOORS (PROVIDED BY GENERAL CONTRACTOR): PROVIDE ACCESS DOORS BY MILCOR OR EQUAL. USE STYLE DW AT WALLS AND CEILINGS, (OR AS REQUIRED FOR RATING). SIZE AS INDICATED. FRAME SHALL BE GALVANIZED STEEL DRYWALL BEAD FOR FRAME CONCEALMENT. PANEL SHALL BE 14GA. STEEL WITH SPRINT TYPE CONCEALED HINGES OPENING TO 175 DEGREES. LOCKS SHALL BE FLUSH, SCREWDRIVER OPERATED WITH METAL CAM. PRIME COAT SHALL BE FACTORY APPLIED. COORDINATE INSTALLATION WITH REQUIREMENTS OF OVERHEAD COILING DOOR MANUFACTURER. HARDWARE 1. ALL FINISH HARDWARE FOR COMPLETE WORK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. QUANTITIES LISTED IN ANY INSTANCE ARE FOR THE CON- TRACTOR'S CONVENIENCE ONLY AND ARE NOT GUARANTEED. ITEMS NOT SPECIFICALLY MENTIONED BUT NECESSARY TO COMPLETE THE WORK FURNISHED, MATCHING IN QUALITY AND FINISHED, THE ITEMS SPECIFIED. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER OPERATION AND FITTING OF HARDWARE IN LOCATIONS SPECIFIED. THE CONTRACTOR MUST SUPPLY A ROOM UNDER LOCK AND KEY TO STORE ALL FINISH HARDWARE UNTIL INSTALLATION IS MADE. THE HARDWARE SUPPLIER MUST MARK EACH ITEM OF HARDWARE AS TO DESCRIPTION AND LOCATION OF INSTALLATION IN ACCORDANCE WITH APPROVED HARDWARE SCHEDULE. EXPOSED SURFACES OF HARDWARE SHALL BE COVERED AND WELL PROTECTED DURING INSTALLATION, SO AS TO AVOID DAMAGE TO FINISHES. 3. PROVIDE HARDWARE FOR FIRE -RATED OPENINGS IN COMPLIANCE WITH REQUIREMENTS OF NFPA 80. THIS REQUIREMENT TAKES PRECEDENCE OVER OTHER REQUIREMENTS FOR SUCH HARDWARE. 4. HARDWARE FINISH SHALL BE SATIN CHROME, U.N.O. 5. HARDWARE SUPPLIER WILL PROVIDE APPROVED SCHEDULED AND PAPER TEMPLATES TO VARIOUS OTHER SUPPLIERS FOR DOOR AND FRAME PREPARATION FOR HARDWARE. 6. FURNISH AND FINISH HARDWARE, CYLINDERS AND KEYS: "BEST" SEVEN PIN ROD. 7. EACH ITEM OF HARDWARE SHALL BE PACKAGED SEPARATELY WITH ALL NECESSARY SCREWS, BOLTS, TAMPINS, KEYS AND INSTALLATION TEMPLATES. DELIVER PACKAGES, CLEARLY IDENTIFIED, WITH HEADING NUMBER AS APPROVED ON HARDWARE SCHEDULE. 8. INSTALL EACH HARDWARE ITEM IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS AND LOCATE IN ACCORDANCE WITH Dhl RECOMMENDED LOCATIONS. SET ITEMS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUB- STRATE, AS NECESSARY, FOR A SECURE INSTALLATION. SPACE FASTENERS AND ANCHORAGE AS INDI- CATED OR IN ACCORDANCE WITH INDUSTRY STANDARDS. 9• MAKE FINAL ADJUSTMENT AND CHECK OF HARDWARE DURING THE WEEK IMMEDIATELY PRIOR TO ACCEPTANCE. CLEAN AND RELUBRICATE OPERATING ITEMS AS NECESSARY, TO RESTORE PROPER FUNCTIONING AND FINISH OF HARDWARE AND DOORS. MAKE FINAL ADJUSTMENT OF LOCKSETS AND THE CLOSURES TO COMPENSATE FOR OPERATION OF HEATING AND VENTILATION SYSTEMS UNDER THE SUPERVISION OF MANUFACTURER'S REPRESENTATIVE. 10. LUBRICATE ALL MOVING PARTS WITH GRAPHITE -TYPE LUBRICANT, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER. REPLACE ALL HARDWARE WHICH CANNOT BE LUBRICATED AND ADJUSTED TO OPERATE FREELY AND SMOOTHLY. It 2246 CgPX�jGHT NOTI_�E' These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 6 4) 40 In co 0 V Go 4 CCa m O V W J _ . LILT. a� o I4 Z O 13 L C 0 V0 E c m c 0 0 CL M Vf N Vf Vf W W Z Z W Z F H Z 0 LLM u W CL N Z O N Z o 6/1/06 SCALE: NONr= DRAWN BY: spi JDD 0 o_ PROJECT No.: a DEM060�4 ' M 3 N N CL 0 o rn � o a 00 "'I to =0+ ro N in c00 �0 0 c o N "t it �00 0 0 a O1 s Zo in e - 5t, in + tA H aR M a�a,TMI a CIS E� �/ i•. 4 ;1 -%c r:- [Am- C 13 C �0 {:J 2 C II� JuN a 'U6 DATE: SHEET: 6/1/06 SCALE: NONr= DRAWN BY: spi JDD PROJECT No.: DEM060�4 SPECIAL DOOR HARDWARE SECTION FOR ds.m.o. 1 • DOORS MUST BE OF HEAVY CONSTRUCTION, HUNG IN A FRAME SUFFICIENTLY STRONG TO AVOID PRYING. HINGES MUST BE EITHER LOCATED WITHIN THE DOORWAY OR THE SCREWS AND BOLTS MUST BE SET IN SUCH A WAY THAT THEY CANNOT BE REMOVED. HINGE PIN SHOULD BE WELDED, FLANGES OR WITH SET SCREWS TO PREVENT REMOVAL. 2• DOOR JAMBS MUST BE OF A STRONG CONSTRUCTION TO PREVENT SPREADING BY A CROWBAR OR AUTOMOBILE JACKS. THE LOCKING BOLT MUST BE AT LEAST ONE (1) INCH INTO THE JAMB FOR PREVENTION OF SPREADING. CYLINDERS SHOULD BE FLUSH OR INSET TO PREVENT "WRENCHING" WITH A 7 -PIN CYLINDER GUARD. 3. ALL MEANS OF INGRESS OF SIXTY (60) SQUARE INCHES OR LARGER MUST BE SCREENED, LOCKED OR GRILLED IN SOME MANNER TO INCLUDE AIR VENTS, MANHOLES, LOADING CHUTES AND ALL OTHER AVENUES THROUGH THE ROOF AND OUTER WALLS. 4. NEVER KEY A JOB WITH PERMANENT KEYING DURING CONSTRUCTION PHASES. LOCKS SHOULD BE PROVIDED WITH CONSTRUCTION CORES AND RE -KEYED BY CORPORATE LOSS PREVENTION OR THE ASSIGNED DISTRICT MANAGER UPON THE COMPLETION OF THE JOB. 5. PERIMETER EMERGENCY EXIT MUST BE PROVIDED. WELDED PLATES AND/OR ONE (1) PIECE CON- STUCTION TO PROTECT FOREIGN OBJECTS FROM INSERTION (ie. WIRE LOOPS TO PANIC BAR HANDLES AND/OR SAWING OF THROW BOLTS.). a. USE "BEST" LOCKING HARDWARE WITH INTERCHANGEABLE CORES. (BY PACIFIC SUNWEAR). b. MASTER KEY SYSTEM/CONTROLLED FROM CORPORATE LOSS PREVENTION. c. ALL CUSTOMER DOORS (PROVIDE IE CYLINDERS, FLUSH OR TAPERED HEAD) WITH A CYLINDER HEIGHT OF 48 INCHES. d. IE -74 -C -181-R-3 (626 FINISH OR THE DESIRED FINISH). ADAMS RITE LOCKS. (OR EQUAL) e. THUMBSCREW (INSIDE GATES) WITH TUBE PROTECTORS. f. EMERGENCY/SERVICE EXIT USE 70-R ALARM (EXIT DEVICE) WITH "BEST" IE72 RIM CYLINDER. (BY PACIFIC SUNWEAR). q. INSIDE CYLINDER ONLY. h. MANAGER OFFICE KEYED 83K7AB94 626 -FINISH. i. STOCKROOM. TOILET, SERVICE AND OFFICE DOORS SHALL BE EQUIPPED WITH AUTOMATIC CLOSERS. (HYDRAULIC TYPE). DIVISION 9 - FINISHES METAL SUPPORT SYSTEM (WALL STUDS) 1. PROVIDE CHANNEL -SHAPED ROLL FORMED SHEET STEEL MEMBERS CONFORMING WITH ASTM C640, HOT DIPPED FINISH WHERE EXPOSED TO MOISTURE NOT LESS THAN 20 GAUGE. PROVIDE 16 GAUGE AT DOOR JAMBS. 2. PROVIDE COLD, ROLLED STEEL CHANNELS NOT LESS THAN 16 GAUGE. 3. PROVIDE ROLL HAT -SHAPED CHANNELS MINIMUM 25 GAUGE, 7/8" DEEP WITH 1/2" HEMMED EDGES. HOT DIPPED FINISH WHERE NOTED. 4. PROVIDE TIE WIRES OF GALVANIZED ANNEALED WIRES NOT LESS THAN 16 GAUGE. 5. PROVIDE GALVANIZED HANGERS OF STEEL WIRE IN ACCORDANCE WITH ASTM C754. 6. PROVIDE JACK STUDS BETWEEN BOTTOM TRACK AND WINDOW AND/OR RELIEF SILLS BETWEEN LINTELS AND HEADERS IN TOP TRACKS. 7. PROVIDE BLOCKING AND FRAMING FOR ALL WALL MOUNTED FINISH HARDWARE AND EQUIP- MENT, INCLUDING DOOR STOPS. 8. PROVIDE CEILING SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS INDICATED ON DRAWINGS. 9. PROVIDE DOUBLE BEAD TO BUTYL SEALANT AT FLOOR TRACKS. APPLY DOUBLE BEAD TO CEILING TRACK AND TO STUDS ABUTTING OTHER CONSTRUCTION. 10. PROVIDE CHANNEL SHAPED BLOCKING SUPPORT OR GALVANIZED STRIP SUPPORT OF WALL -HUNG CABINETS, EQUIPMENT, FIXTURES AND ACCESSORIES OF NOT LESS THAN 22 GA. MATERIAL. PRO- VIDE SUPPORT IN WALL OR PARTITION FRAMING SYSTEM WHEREVER WALL HUNG CABINETS AND EQUIPMENT ARE INDICATED ON DRAWINGS. AND WHERE REQUIRED FOR MOUNTING OF MISCEL- ANEOUS ITEMS REQUIRING BACKING. 11. SET FLOOR TRACKS IN ACCURATE LOCATIONS AND SECURELY ANCHOR IN ACCORDANCE WITH ASTM STANDARDS. ERECT STUDS ON 16" OR 24" (AS INDICATED) CENTERS AND SECURE TO TRACK. INSTALL HEAD TRACK IN ACCORDANCE WITH DETAILS. INSTALL BLOCKING, BRACING, AND ANCHOR STRIPS; LEAVE READY TO RECEIVE FINISH MATERIALS. 12. ERECT ALL COMPONENTS FOR CEILING AND SOFFIT FRAMING IN ACCURATE LOCATIONS AS INDICATED, TRUE TO LINE, LEVEL AND PLUMB, AND IN ACCORDANCE WITH APPLICABLE ASTM STANDARDS AS REFERENCED ABOVE, USING A LASER LEVEL. ADJUST SUPPORTS, SPANS OR OTHERWISE FOR INSTALLATION WITHIN SPECIFIED TOLERANCES, 13. PROVIDE KICK BRACING IN ACCORDANCE WITH INDUSTRY STANDARDS FOR WALL STUDS, CEIL- ING MEMBERS, DRAFT OR SMOKE STOPS AND CURTAIN WALLS. PAINTING 1. PROVIDE PAINT FINISHES FOR BUILDING AND OTHER SURFACES AS SCHEDULED ON DRAWINGS OR AS SPECIFIED HEREINAFTER INCLUDING SEALING OF CONCRETE FLOOR AT CORRIDOR AND STOCKROOM. NO PAINT FINISH IS REQUIRED ON ITEMS HAVING COMPLETE FACTORY FINISH, EXCEPT AS MAY BE SPECIFIED HEREINAFTER; PUTTY AND/OR SEALANT AT ALUMINUM WIN- DOWS; NON-FERROUS METAL UNLESS SPECIFICALLY MENTIONED IN THE PAINTING SCHEDULE; STAINLESS STEEL; INTERIOR OR EXTERIOR OF EXISTING BUILDING, EXCEPT WHERE ALTERATIONS OCCUR OR WHERE SCHEDULED. PAINT GRILLES AND DIFFUSERS. NO PAINTING IS REQUIRED FOR INSULATING PIPING, EXCEPT WHERE EXPOSED IN FINISH, NON-MECHANICAL ROOM SPACES. 2. PROTECT WORK OF OTHER TRADES FROM DAMAGE AND DEFACEMENT CAUSED BY THIS WORK. REPAIR ANY DAMAGE CAUSED BY THE WORK OF THIS SECTION. REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSERS, GRILLES, ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO COMMENCING THE WORK. STORE, CLEAN, AND REPLACE UPON COMPLETION. 3. PAINT CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IF ANY SURFACE TO BE PAINTED OR STAINED IS FOUND TO BE UNSUITABLE TO PRODUCE PROPER FINISH. APPLY NO FINISH MATERIAL UNTIL THE UNSUITABLE SURFACES HAVE BEEN MADE SATISFACTORY. 4. FINISH WORK SHALL BE UNIFORM, OF APPROVED COLOR, SMOOTH AND FREE FROM RUNS. MAKE ENDS OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN. WHERE HIGH GLOSS ENAMEL IS USED, LIGHTLY SAND UNDERCOAT TO OBTAIN A SMOOTH FINISH COAT. 5. PROVIDE ALL NEWLY PAINTED SURFACES WITH (1) COAT TINTED PRIMER AND (2) COATS FI- NAL COLOR COAT, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER'S SPECIFICATIONS. 6. DELIVER ALL PAINT TO JOBSITE IN UNOPENED CONTAINERS BEARING THE MANUFACTURER'S LABEL, AND SHOWING PAINT TYPE, SHEEN AND COLOR. 7. PAINT TYPES USED SHALL BE THOSE SPECIFICALLY RECOMMENDED BY THE MANUFACTURER FOR THE MATERIAL TO WHICH THEY WILL BE APPLIED. PAINTING CONTRACTOR SHALL FOL- LOW MANUFACTURER'S INSTRUCTIONS FOR PROPER APPLICATION OF THE PAINT. 8. ALL SURFACES TO BE PAINTED SHALL BE THOROUGHLY CLEANED, AND PREPARED FOR PAINTING PRIOR TO APPLICATION OF PAINT. PROVIDE VENTILATORS AS REQUIRED TO PREVENT BUILD-UP OF FUMES. 9. SANDPAPER ALL NEW WOOD TO SMOOTH AND EVEN SURFACE AND DUST OFF. AFTER PRIM- ING COAT HAS BEEN APPLIED, THOROUGHLY FILL ALL NAIL HOLES AND OTHER SURFACE IM- PERFECTIONS WITH PUTTY TINTED WITH PRIMER OR STAIN TO MATCH WOOD COLOR. SAND ALL WOODWORK BETWEEN COATS TO A SMOOTH SURFACE. 10. PRIME ALL SURFACES WHICH RECEIVE PAINT PRIOR TO APPLICATION OF FINAL FINISH, IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 11. BACK PRIME ALL EXTERIOR AND INTERIOR WOOD AND TRIM PRIOR TO INSTALLATION. THOR- OUGHLY CLEAN SURFACES AND APPLY NO FINISH UNLESS SURFACES ARE DRY AND READY FOR APPLICATION. SANDPAPER SURFACES OF TRIM SMOOTH AND WIPE CLEAN. AFTER STAIN COAT HAS BEEN APPLIED, FILL CRACKS AND HOLES WITH PLASTIC WOOD OR PUTTY. IF STAIN HAS BEEN USED, TINT CRACK FILLER TO MATCH; PRIME BACKS OF TRIM. PRIME BARE WOOD SCHEDULED TO RECEIVE PAINT FINISH; FINISH NAIL HOLES, CRACKS, AND OTHER IMPERFECT- IONS WITH PUTTY AND SAND SMOOTH. 12. AT COMPLETION, TOUCH-UP AND RESTORE FINISH WHERE DAMAGED AND LEAVE ALL SUR- FACES IN GOOD AND CLEAN CONDITION. PROVIDE FOR MULTIPLE SITE VISITS AS REQUIRED FOR TOUCH-UP AND REFINISHING. 13. OTHER PAINT MANUFACTURER'S MAY NOT BE SUBSTITUTED. 14. FINISH INTERIOR SURFACES, AS SCHEDULED ON DRAWINGS, EXCEPT AS MODIFIED AND SUP- PLEMENTED HEREINAFTER AND UPON WRITTEN OWNER APPROVAL. IN GENERAL, USE EGGSHELL SHEEN FOR WALL BOARD SURFACES; SEMI -GLOSS FOR HOLLOW METAL AND WOOD TRIM; AND FLAT FOR DUCTWORK. SPECIFICATIONS RESILIENT BASE 1. INSTALL COVE BASE IN AREAS AS CALLED FOR IN PLANS & OR ELEVATIONS. 2. PROVIDE PREMOLDED INSIDE AND OUTSIDE CORNERS FOR ALL CONDITIONS AT WHICH CORNERS ARE TO BE USED. JOB MITERING SHALL BE PERMITTED ONLY UPON OWNER'S APPROVAL. 3. USE ADHESIVES ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO WHICH IT IS APPLIED. 4. CAREFULLY INSPECT ALL SURFACES TO RECEIVE BASE PRIOR TO INSTALLATION, REPAIR DAMAGED SURFACES PRIOR TO INSTALLATION. 5. UPON COMPLETION, IMMEDIATELY REMOVE ALL SURPLUS ADHESIVE FROM ADJACENT SURFACE, IN ACCORDANCE WITH THE TIMING RECOMMENDED BY THE MANUFACTURER, USING MATERIALS RECOMMENDED FOR THAT PURPOSE BY THE MANUFACTURER. GLASS & GLAZING 1. PROVIDE TEMPERED GLASS, GRADE "B", STYLE #1, TYPE "1", QUALITY 03, 1/2" THICK. 2. ALL GLASS EDGES SHALL BE GROUND SMOOTH &. POLISHED. 3. GENERAL GLASS SHALL BE q3 IN ACCORDANCE WITH FEDERAL SPECIFICATIONS DD -G-451 AND FGMA GLAZING MANUAL. 4. STOREFRONT GLASS SHALL BE AS REQUIRED FOR THE SIZES AND CONDITIONS DETAILED. FRAME SECTION SHALL BE CONCEALED WHERE INDICATED. 5. PROVIDE RESILIENT NEOPRENE BLOCKS 70 TO 90 SHORE A DUROMETER HARDNESS AND RESILIENT ACCESSORIES DESIGNED FOR POSITIONING GLASS IN RABBETS. 6. PROVIDE CLIPS OF NON -CORROSIVE METAL WITH ROUNDED EDGES DESIGNED FOR CONTACT BLOCKS, NOT GLASS. 7. PROVIDE STANDARD PREFORMED GLAZING TAPE, STANLOCKE 400, TRIMCO 440, OR APPROVED. 8. PROVIDE NON -SHRINKING ELASTOMERIC TAPE WHERE REQUIRED. 9. USE SILICONE SEALANT DOW #795 OR GE SILPRUF, COLOR AS SPECIFIED, OR APPROVED EQUAL.. 10. ALL EDGES, DRILLED HOLES AND NOTCHES SHALL BE FACTORY CUT AND/OR FACTORY FORMED. TOUCH-UP "RAW" EDGES TO MATCH FRAME. 11. INSTALL IN ACCORDANCE WITH FGMA RECOMMENDATIONS UNLESS NOTED OTHERWISE. 12. VERIFY THAT FRAMES TO RECEIVE GLAZING ARE SQUARE AND TRUE, THAT PERIMETER CLEAR- ANCES ARE SUFFICIENT TO PREVENT "POINT LOADING", AND THAT SURFACES ARE CLEAN, DRY AND READY TO RECEIVE GLAZING MATERIALS. REMOVE ALL PROTECTIVE COATINGS FROM FRAMING SURFACES. 13. CENTER GLASS IN RABBETS AND POSITION SO AS TO MAINTAIN CLEARANCES ON ALL SIDES, INDOORS AND OUT, IN ACCORDANCE WITH FGMA RECOMMENDATIONS. SHIM AS REQUIRED TO POSITION AGAINST FIXED STOPS AND FRAME BARS. 14. SET ALL EXTRUSIONS IN CORRECT LOCATIONS AS SHOWN IN THE DETAILS. THEY SHALL BE LEVEL, FLUSH, SQUARE, PLUMB AND IN ALIGNMENT WITH OTHER WORK. 15. UPON COMPLETION, REMOVE ALL EXCESS SEALANT AND MATERIALS FROM SURFACES; WASH AND CLEAN ALL GLASS FRAMING MEMBERS, SUSPENDED ACOUSTICAL CEILING 1. SYSTEM COMPONENTS SHALL CONFORM TO ASTM C635 INTERMEDIATE DUTY AND UBC STANDARD 47-18 INTERMEDIATE DUTY. INSTALLATION OF SYSTEMS SHALL CONFORM TO ASTM C636, WITH A DEFLECTION OF NOT MORE THAN 1/360 OF THE SPAN. FURNISH AND INSTALL ALL LABOR AND MATERIALS FOR COMPLETE ACOUSTICAL CEILING. REVIEW JOB SCHEDULE TO VERIFY INSTALLATION DATES AND MATERIAL AVAILABILITY. 2. COORDINATE ACOUSTICAL SUSPENSION SYSTEM WORK WITH OTHER WORK, SUCH AS CEILING LIGHT FIXTURES AND AIR OUTLETS. PROTECT FINISHED WORK INSTALLED BEFORE INSTALLATION OF ACOUSTICAL SUSPENSION SYSTEM. REPLACE WORK DAMAGED BY WORK UNDER THIS SECTION. THE TENANT'S G.C. SHALL MAINTAIN FIRE AND SMOKE RATINGS AS REQUIRED BY CODES AND LANDLORD'S SPECIFICATIONS AND REGULATIONS. 3. ALL LOCKING CROSS TEES SUPPORTING OTHER CROSS TEES SHALL CONFORM TO THE SAME CLASSIFICATION AS THE MAIN RUNNERS. MAIN RUNNERS AND CROSS TEES SHALL BE COLD ROLLED ELECTRO -GALVANIZED STEEL. WALL ANGLE MOLDINGS SHALL BE COLD ROLLED ELECTRO -GALVANIZED STEEL. CORNERS SHALL BE MANUFACTURER'S PREFABRICATED INSIDE AND OUTSIDE CORNER MOLDINGS. 4. FINISH SHALL BE BAKED ENAMEL IN SELECTED COLOR. 5. HANGER WIRE SHALL BE 12 GAUGE GALVANIZED STEEL WIRE CONFORMING TO FS QQ-W-4.61, TYPE I. 6. INSPECT LOCATIONS TO RECEIVE WORK AND CHECK THE EXISTING DIMENSIONS. ASCERTAIN BEFORE PROCEEDING WITH WORK THAT ALL REQUIRED INSPECTIONS HAVE BEEN MADE. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF RESPONSIBILITY RELATED TO GUARANTEE REQUIREMENTS, THE BUILDING SHALL BE EXAMINED BEFORE BEGINNING WORK TO DETERMINE THAT IT IS PRO- PERLY ENCLOSED AND THE STRUCTURE IS IN PROPER CONDITION TO RECEIVE ACOUSTICAL MA- TERIALS. THE AREA SHALL BE BROOM CLEANED AND UNINTERRUPTED FOR FREE MOVEMENT OF SCAFFOLD- ING. SCAFFOLDING SHALL BE OF A TYPE THAT WILL NOT SCAR OR MAR FLOOR SURFACES AND WILL NOT DAMAGE OTHER CONSTRUCTION. WORK NOT TO PROCEED UNTIL SATISFACTORY CON- DITIONS DESCRIBED ABOVE PRESIDE. 7. ATTACH HANGER WIRE TO SOUND, SECURE STRUCTURAL MEMBERS CAPABLE OF CARRYING THE NEW LOAD WITHOUT DEFLECTION. WRAP, BOLT OR CLIP WIRE HANGERS TO STRUCTURAL STEEL MEMBERS, OR INSTALL DROP CLIPS ON STRUCTURAL STEEL MEMBERS AND TIE WIRE HANGERS TO DROP CLIPS. INSTALL SUPPLEMENTARY FRAMING, BLOCKING AND BRACING WHERE NECESSARY TO SUSPEND CEILING SYSTEM FIXTURES AND EQUIPMENT AND WHERE SPACING OF STRUCTURAL SUPPORTS EXCEEDS SPECIFIED HANGER SPACING. WHERE DIRECT SUSPENSION OF SUPPLEMENTARY FRAMING FOR SUPPORT OF EQUIPMENT, FIXTURE OR DUCTWORK IS NOT POSSIBLE DUE TO OBSTRUCTIONS, SUPPLEMENTARY FRAMING MAY BE SUSPENDED BY "TRAPEZE" ARRANGEMENT OF HANGER WIRE. SUSPEND LIGHT FIXTURES FROM STRUCTURE BY ATTACHMENT OF ONE HANGER AT EACH CORNER OF THE FIXTURE. FURNISH ADDITIONAL WIRES FOR LIGHTING FIXTURES AND MECHANICAL REGISTERS IN SUSPENDED CEILING. PROVIDE SEISMIC BRACING AS REQUIRED. S. INSTALL CEILING SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM 0636. LOADING OF ANY COMPONENT MAY NOT CAUSE DEFLECTION OF MORE THAN 1/360 OF THE SPAN. USE LASER LIGHT FOR LAYOUT AND LEVELING. INSTALL MAIN RUNNERS 48 INCHES O.C• TIE HANGER WIRES TO MAIN RUNNERS TIGHTLY WITH AT LEAST THREE FULL TURNS. INTERCONNECT MAIN RUNNERS BY LOCKING CROSS TEES 48 INCHES LONG TO FORM 24 INCH BY 48 INCH MODULES, WHEREVER SHOWN ON THE DESIGN PLANS, THESE MODULES SHALL BE DIVIDED BY CROSS TEES 24 INCHES LONG INSTALL PER- PENDICULAR TO THE OTHER CROSS TEES TO FORM 24 INCH BY 24 INCH SECTIONS. PROPER LENGTH LOCKING CROSS TEES SHALL ALSO BE INSTALLED ADJACENT TO ALL SIDES OF RECESSED LIGHT FIXTURES NOT SUPPORTED BY A MAIN RUNNER. 9. ALL SUSPENDED CEILINGS SHALL BE BRACED TO RESIST LATERAL AND HORIZONTAL MOVEMENT AS REQUIRED BY THE GOVERNING CODES. THE TENANT'S G.C. SHALL VERIFY ALL APPLICABLE CODES AND CONFORM. 10. CUT TILES TO MATCH FIELD PATTERN RECESS. ANY ACOUSTICAL CEILING PANELS LESS THAN FULL SIZE SHALL HAVE CUT EDGES TRIMMED TO MATCH FACTORY TEGULAR EDGES. SUSPENDED CEILING SHALL HAVE INTERSECT ALL VERTICAL WALLS AT 900 UNLESS OTHERWISE NOTED. 11. UPON COMPLETION OF WORK FOLLOWING INSTALLATION OF SUSPENSION SYSTEMS, DIRTY OR DISCOLORED SURFACES OF SUSPENSION COMPONENTS SHALL BE CLEANED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND LEFT FREE FROM DEFECTS. COMPONENTS THAT ARE DAMAGED OR IMPROPERLY INSTALLED BE REMOVED AND REPLACED WITHOUT ADDITIONAL COST TO THE OWNER. 12. LEAVE 1 FULL CASE, UNDAMAGED TILES AT JOBSITE, DIVISION 10 - SPECIALTIES 1. TENANT'S G.C. SHALL PROVIDE ADEQUATE BACKING FOR SECURE INSTALLATION OF ACCESSORIES. 2, ALL ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH ALL GOVERNING NATIONAL, STATE AND LOCAL CODES PERTAINING TO HANDICAP ACCESSIBILITY. ACCESSORIES: SP -1 TOILET PAPER HOLDER: AS SELECTED BY TENANT G.C. AND APPROVED BY OWNER. SP -2 NOT USED SP -3 MIRROR: AS SELECTED BY TENANT G.C. AND APPROVED BY OWNER. SP -4 GRAB BARS: AS SELECTED BY TENANT G.C. AND APPROVED BY OWNER. SP -5 PAPER TOWEL DISPENSER: AS SUPPLIED BY PACIFIC SUNWEAR, INSTALLED BY G.C. SP -6 TRASH CONTAINER: "RUBBERMAID" 2952, 8 1/2 QT. BEIGE VINYL CONTAINER. (BY OWNER) INSTALLATION: 1. DELIVER INSERTS AND ROUGH -IN FRAMES TO JOBSITE AT APPROPRIATE TIME FOR BUILDING IN. 2. FASTENINGS: FURNISH TOILET ACCESSORIES TO COMPLETE WITH ALL REQUIRED MOUNTING DEVICES, FASTENINGS, AND ACCESSORIES AS REQUIRED FOR A FINISHED INSTALLATION, PRO- PERLY PACKAGED AND TAGGED FOR READY IDENTIFICATION. FASTEN ALL ITEMS WITH SCREWS OR BOLTS EXTENDING AT LEAST 1" INTO SOLID BACKING IF NO OTHER FASTENING IS SPEC- IFIED. 3. INSTALLATION OF TOILET ACCESSORIES SHALL BE IN ACCORDANCE WITH THE DRAWINGS, RE- VIEWED SHOP DRAWINGS, AND THE MANUFACTURER'S INSTALLATIONS AND RECOMMENDATIONS. 4. TEN. G.C. SHALL SUPPLY & INSTALL ADEQUATE BACKING FOR SECURE INSTALLATION OF ALL ACCESSORIES. MOUNTING: 1. LOCATIONS AND HEIGHTS, SHALL BE AS SHOWN ON DRAWINGS AND IN CONFORMANCE WITH 'HANDICAP' ORDINANCES. SIGNS 1, SIGNS ARE SUPPLIED & INSTALLED BY OWNERS SIGN CONTRACTOR. G.C. SHALL PROVIDE POWER SOURCE & REQUIRED DISCONNECTS, TIME CLOCKS ETC., COORDINATE WITH SIGN CONTRACTOR AS REQUIRED. G.C. TO INSTALL FOOTGEAR SIGN, INT. HANGING SIGN, WINDOW LOGO AND DIAMOND PLATE SIGN, FIRE EXTINGUISHERS (PROVIDED BY G.C.) 1. EXTINGUISHERS SHALL BE 10 -POUND CAPACITY, U.L. LABELS, ENAMEL, STEEL CONTAINER WITH PRESSURE INDICATING GAUGE FOR CLASS A, B, OR C FIRES. 2. INSTALL ON WALL MOUNTED HOOKS AS INDICATED OR DIRECTED BY THE MARSHALL, NEATLY FITTING TO FINISH SURFACES. PLACE FULLY CHARGED EXTINGUISHERS ON HOOKS PRIOR TO OCCUPANCY. 3. SEE FIXTURE PLAN FOR ARCHITECTS SUGGESTED LOCATIONS. ANTI -THEFT SYSTEM SENSORMATIC: 1. PROVIDE (1) 115V, 3 -WIRE, 24 HOUR CIRCUIT WITH (1) DUPLEX RECEPTACLE, FOR SYSTEM POWER -IN SOFFIT AREA STOREFRONT. 2. TRADES SHALL COORDINATE WITH SENSORMATIC INSTALLER THROUGH ALL PHASES OF CON- STRUCTION FOR INTEGRAL SYSTEM INSTALLATION. SENSORMATIC ELECTRONICS CORPORATION 3960 VIA ORO AVENUE, SUITE 110 LONG BEACH, CALIFORNIA 90180 1 (800) 241-6678 CONTACT: CECELIA MORENO AUDIO/VIDEO NOTES: 1. ALL AUDIO AND VIDEO CABLES SHALL BE RUN IN CONDUIT. (UNLESS OTHERWISE NOTED) 2. LEAVE ADEQUATE AMOUNT OF SLACK IN AUDIO AND VIDEO CABLES FOR PROPER POSITIONING OF EQUIPMENT AFTER INSTALLATION. 3. EXCESS LENGTHS OF CABLE SHALL BE CONCEALED IN BRACKETS OR CEILING, EQUIPMENT: 1. (1) RECEIVER - PLAYNETWORKS 2. (4) SPEAKERS - MODEL 203 3. BOSE AMP NOTE: ITEMS 1, 2 IN THIS SECTION ARE FURNISHED BY "BOSE CORP" & "PLAYNETWORKS." (G.C. TO SUPPLY CONDUIT W/ PULL STRING. (UNLESS OTHERWISE NOTED) GYPSUM WALL BOARD 1. PROVIDE GYPSUM WALL PANELS MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF ASTM 3.36. 2. PROVIDE TYPE 'X' FIRE RETARDANT GYPSUM WALL BOARD PANELS 5/8" THICK, TESTED & QUALIFIED FOR 1 -HOUR RATING, TAPERED AND ROUNDED AT EDGES AS INDICATED ON DRAWINGS. 3. PROVIDE METAL EDGE AND CORNER BEADS AT ENDS, EDGES AND CORNERS. 4. WATER RESISTANT GYPSUM WALL BOARD SHALL BE 5/8" THICK, QUALIFIED FOR 1 -HOUR RATING, TAPERED AND ROUNDED EDGES AND SHALL BE INSTALLED IN ALL WET AREAS AS INDICATED ON DRAWINGS. 5. PROVIDE FASTENERS IN ACCORDANCE W/ ASTM C646; UNLESS OTHERWISE NOTED OR INDICATED, PROVIDE TYPE 'S' BUGLE HEAD SCREWS FOR ATTACHMENT OF WALL BOARD TO METAL FRAMING, AND TYPE 'S' PAN HEAD SCREWS FOR ATTACHMENT OF FRAMING TO DOOR FRAMES. 6. PROVIDE ALL INCIDENTAL & ACCESSORY MATERIALS, TOOLS, EQUIPMENT, AND METHODS REQ'D FOR SATISFACTORY COMPLETION OF GYPSUM WALL BOARD CONSTRUCTION INCLUDING ACCESS DOORS AND PANELS. 7, APPLY CONTINUOUS BEAD SEALANT AT ALL JOINTS OF WALL BOARD ABUTTING ADJACENT CONSTRUCTION, INCLUDING AROUND FRAMED OPENINGS AND OTHER PROTRUSIONS THROUGH WALL BOARD WHERE SEALANT IS EXPOSED. PROVIDE POLY -SULFIDE SEALANT; WHERE INDICATED, PROVIDE ACOUSTIC SEALANT. 8. APPLY PRE -FILL COMPOUND TO JOINTS IN ACCORDANCE WITH INDUSTRY STANDARDS. APPLY EMBEDDING COMPOUND REINFORCING TAPE CENTERED OVER JOINT; APPLY SKIM COAT. AFTER TAPING & EMBEDDING COMPOUND IS DRY, APPLY SECOND COAT FILLING & TAPER FLUSH W/ SURFACE; FIRE TAPE PENETRATIONS AT DEMISING WALLS, CORRIDOR ENVELOPE & OTHER RATED ASSEMBLIES. 9, PROVIDE FINAL FINISH THAT IS SMOOTH, WITHOUT DIVOTS, BUMPS, BOWS OR ANY OTHER SURFACE BLEMISH, READY TO RECEIVE PAINT. 10. CUSTOM SKIP TROWELED FINISH WHERE SPECIFIED ON PLANS. COORDINATE FINISH WITH ARCHITECT. CONTACTS MDC WALLCOVERINGS SHERWIN WILLIAMS WOLF GORDON JM LYNNE 1200 ARTHUR AVENUE 2920 W. COCHISE DRIVE 33-00 47TH AVENUE THE DESIGNTEX GROUP ELK GROVE, IL 60007 PHOENIX, AZ 85051 LONG ISLAND CITY, NY 11101 2141 E. CAMELBACK RD P: 800.621.4006 P: 888.365.6042 P: 800.347.0550 EXT. 820 SUITE 240 C: 602.486.0528 C: 602.758.4871 F: 718.361.1090 PHOENIX, AZ 85016 F: 847.437.4017 F: 602.870.8955 CONTACT: SHEILA SHANKLIN P: 602.955.0099 CONTACT: SHARON HODGSON CONTACT: JACKIE JORDAN F: 602.257.8429 cc WILSONART CONTACT: TRACY BEIAN- O 0 STUDIO SOURCE 2636 S. WILSON ST. KIRK WALL RESOURCES SUITES 101 & 102 146 E. CORONADO RD. TEMPE, AZ 85282 ROPPE 0Vo SUITE #39 P: 480.921.9906 BIG D FLOORS PHOENIX, AZ 85004 C: 602.763.4461 2802 W. VIRGINIA AVE. J P: 602.254.2833 F: 480.921.1205 PHOENIX, AZ 85009 �o C: 602.577.9566 CONTACT: CHUCK WELCH P: 602.442.2222 3:ZV F: 888.322.3772 � Q co o C: 602.317.0894 CONTACT: JUDY KELLY �0 F: 602.352.1116 0 ■�0 O CONTACT: DOUG JAMES PAINT FINISH SCHEDULE P-1 NOT USED P-2 "SHERWIN WILLIAMS", SW 6119 ANTIQUE WHITE - SALES WALLS 2 COATS PROMAR 200 SEMI -GLOSS OVER ONE COAT OF PREPRITE LATEX PRIMER. FLAME SPREAD: 10 / SMOKE DENSITY: 0 P-3 "SHERWIN WILLIAMS", SW 6006 BLACK BEAN - STRUCTURE ABOVE 2 COATS PROMAR 200 EGGSHELL OVER ONE COAT OF PREPRITE LATEX PRIMER. FLAME SPREAD: 10 / SMOKE DENSITY: 0 P-4 WHITE ENAMEL FOR STOCK ROOM 2 COATS PROMAR 200 SEMI -GLOSS OVER ONE COAT OF PREPRITE LATEX PRIMER. FLAME SPREAD: 10 / SMOKE DENSITY: 0 P-5 SHERWIN WILLIAMS , SW 6869, STOP - REAR DOOR 2 COATS PROMAR 200 SEMI -GLOSS OVER ONE COAT OF PREPRITE LATEX PRIMER (SUGGESTED PRIMER COLOR - DARK TAN). FLAME SPREAD: 10 / SMOKE DENSITY: 0 METALS, AND FINISHES MF -1 CUSTOM PAINTED METAL, PEARL METALLIC PROVIDED BY OWNER'S STOREFRONT CONTRACTOR. VINYL COMPOSITION TILE VCT -1 12" X 12" ARMSTRONG EXCELON VCT #51836 - SHELTER WHITE, INSTALL WITH MANUFACTURE ADHESIVE - STOCKROOM & TOILET ROOMS VCT -2 NOT USED WOOD STAINS ST -1 STAINED WOOD TRIM PROVIDED BY OWNER'S FIXTURE CONTRACTOR SLATWALL SW -1 METAL SLATWALL - SUPPLIED BY OWNER'S FIXTURE CONTRACTOR. WOOD FLOORING WF -1 LAUZON "AFRICAN SAPELE" 3 1/4" WIDE STRIPS OF RANDOM LENGTHS. SEMI-GLOSS/SEMI-LUSTER. CONTACT: FLOOR TECH 2184 N. BATAVIA ST. ORANGE, CA 92865 ED PLOEGER (714) 998-8881 FAX: (714) 998-9481 TILE FLOORING FT -1 18" X 18" MARBLE TILE CREMA MARFIL. USE WITH CUSTOM BUILDING GROUT, #10 CREAM, 1/8" GROUT JOINT. CONTACT: FLOOR TECH ED PLOEGER (714) 998-8881 BASE FT -2 18" X 18" MARBLE TILE, ON A 45 DEGREE ANGLE, ROJO ALICANTE. USE WITH CUSTOM BUILDING GROUT, #384, 1/8" GROUT JOINT.. CONTACT: FLOOR TECH ED PLOEGER (714) 998-8881 NOTE: USE #10 CREAM GROUT BETWEEN FT -1 & FT -2 FT -3 6" X 6" QUARRY TILE (DAL -TILE #0046 CAMEL) W/ INTEGRAL 6" HIGH QUARRY TILE COVED BASE. PROVIDE WATERPROOF MEMBRANE UNDER THINSET. B-1 6" HIGH SOLID OAK BASE STAINED ST -1, SUPPLIED BY OWNER'S FIXTURE CONTRACTOR. B-2 ROPPE #00 BLACK 6" HIGH RUBBER BASE, INSTALL W/ MFGRS. RECOMMENDED ADHESIVE. - NON SALES & TOILET ROOM CROWN MOULDING 6" HIGH CROWN MOULDING (PRE -FINISHED) SUPPLIED BY OWNER'S FIXTURE CONTRACTOR. WALLCOVERING WC -1 WOLF GORDON G3315110 VESCOM SHANNON, 9429-2 - STOREFRONT. FLAME SPREAD: 15 / SMOKE DENSITY: 45 WC -2 JM LYNNE ESSEX KNOCKOUT SP -31-26 LUMINA - FITTING ROOM. FLAME SPREAD: 10 / SMOKE DENSITY: 5 WC -3 STUDIO SOURCE, TC 3469 CHAMELEON - BACK WALL, DEMISING WALL 0 FITTING ROOM & COLUMNS. FLAME SPREAD: 0 / SMOKE DENSITY: 5 NOTE: ALL WALLCOVERINGS ARE SUPPLIED BY OWNER. PLASTIC LAMINATE PL -1 WILSONART, D485-07 PEARL BISQUE, TEXTURED GLOSS. FLAME SPREAD: 50 / SMOKE DENSITY: 100 PL -2 WILSONART, D488-07 PEARL DUST, TEXTURED GLOSS. FLAME SPREAD: 50 / SMOKE DENSITY: 100 PL -3 NOT USED FIBERGLASS REINFORCED PANELS FRP-1 MARLITE FIBERGLASS REINFORCED PANELS, WHITE. FLAME SPREAD: 200 / SMOKE DENSITY: 450 NOTE: 1, PROVIDE ALL MATCHING TRIM AND MOLDINGS. 2. SILICONE ALL MOLDINGS TO WALL PANEL WITH COLORED SILICONE TO MATCH PANEL. 3. WATER RESISTANT WALLS ARE REQUIRED BEHIND ALL SINKS AND DISHWASHERS. NOTE: NO WOOD ABOVE CEILING. .... ., .....,. . , , ... +•',. fi.fl ' lFia.,.i. L! ..., i.la ,+,. r i ........' 2246 !;_QeYRj.CNT NOTIQ.E. These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition Under such of spaces, and elements of the design. protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. Z Cl � �_ NONE S V H Lam■ Z LLM N W Z � LL Vf DEM06024 cc O 0 C a w j M N N cc N 0Vo v 00 00 F, d �a 1 LL W J fV G00 a� cc, �o 0 3:ZV � Q co o ~ �0 SIM 0 ■�0 O V %= _ Z 00 CL M Vf N at IL z z W z J H W DATE: IM Z Cl � SCALE: NONE S V H S P2 Z LLM N W Z � LL Vf N Z N z DATE: SHEET: SCALE: NONE S DRAWN BY: S P2 v0 PROJECT No.: DEM06024 cc O 0 a w j M N N CL n a°ii v 00 00 F, d �a 1 LL fV G00 �o N d E � Q co o oa,O1 inaa�i`'' f Lc+ l!•:�`}"771 ,^ 2 n .0 'G u. 0 Si+;ti C L� 1� JUN b '06 DATE: SHEET: SCALE: NONE DRAWN BY: S P2 DD PROJECT No.: DEM06024 DOOR NOTES 1 . STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBODIMENT OF NOT LESS THAN 5/8" 2. A HOOK -SHAPED OR AN EXPANDING LUG DEADBOLTS SHALL HAVE A MINIMUM THROW OF 3/4" 3. EXIT HARDWARE: ALL EXITS SHALL BE OPERABLE FROM THE INTERIOR OF TENANTS SPACE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE, NO MANUALLY OPERATED\ EDGE OR SURFACE BOLTS SHALL BE USED 4. MAXIMUM PULL FORCES FOR INTERIOR AND EXTERIOR DOORS SHALL BE: INTERIOR DOORS = 5.0 LBS. FORCE EXTERIOR DOORS = 7.5 LBS FORCE 5. ALL DOOR HARDWARE SHALL HAVE A SATIN ALUMINUM FINISH. 6. ALL EXIT DOORS SHALL BE NOT LESS THAN 3'--0" WIDE AND NOT LESS THAN 7'-0" HIGH 7_ DOORS 1N ANY POSITION SHALL NOT REDUCE THE REQUIRED CORRIDOR WIDTH BY MORE THAN ONE HALF. 8 THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. 9. INTERIOR DOORS SHALL HAVE 18" CLEAR ON THE STRIKE EDGE OF DOOR, 10. MANEUVERING CLEARANCES AT DOORS SHALL HAVE A LEVEL AND CLEAR AREA IN THE DIRECTION OF DOOR SWING A MIN. OF 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48". 11. HAND -ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44" ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND -ACTIVATED AND WHIICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 12, FLOOR LEVEL AT DOORS SHALL NOT BE MORE THAN 1/2" LOWER THAN THRESHOLD. 13. DOORS AT TENANT SPACES SHALL BE OPERABLE FROM WITHIN WITHOUT THE USE OF ANY SPECIAL KNOWLEDGE OR EFFORT WHEN THE SPACE IS OCCUPIED. PER I.B.C. 1003.3.1.8. Q n ass RESP. SCHEDULE (CONT.) ITEM FURNISHED • INSTALLED • • REMARKS • PROVIDED BY LANDLORD MARBLE THRESHOLD • • • SEE HVAC PLAN WAINSCOT • • • • SEE HVAC PLAN LAVATORY • • • • CLEAR ANODIZED ALUM. WHERE INDICATED TOILET • V�xx • • CONTACT MALL MANAGER FOR SPECIFICATIONS H • W • TOILET FLOORING & BASE • • • • • • • PROVIDED BY LANDLORD MARBLE THRESHOLD • • • SEE HVAC PLAN WAINSCOT • • • • SEE HVAC PLAN LAVATORY • • • • CLEAR ANODIZED ALUM. WHERE INDICATED TOILET • • • CONTACT MALL MANAGER FOR SPECIFICATIONS CEILING SYSTEM • • • • SEE DOOR SCHEDULE ACCESSORIES • • • • MIRROR, GRAB BARS PAPER TOWEL HOLDER • • • SANITARY RING HOLDER• • • • • INCLUDING REVEALS EXHAUST FAN & CONNECT • • • T.P. HOLDER • • • SEE SCHEDULE STEREO SYSTEM • • • • G.C. TO RUN CONDUIT & PROVIDE PULL STRING MERCHANDISING HDW. • • • ELECTRICAL CONDUIT TO SPACE • • • • • • • PROVIDED BY LANDLORD SERVICE WIRE TO SPACE • • • SEE HVAC PLAN PANEL "L" • • • • SEE HVAC PLAN DISTRIBUTION • • • • CLEAR ANODIZED ALUM. WHERE INDICATED TRANSFORMER • • • CONTACT MALL MANAGER FOR SPECIFICATIONS MAIN DISCONNECT • • • • SEE DOOR SCHEDULE ROLL -UP GRILLE • • • • SEE LIGHT FIXTURE SCHEDULE SIGN CANOPY • • • NOTES: 1. G.C. TO EXTEND CONDUIT & WIRE WITHIN SPACE. 2. G.C. TO PROVIDE PULLSTRINGS FOR ALL LOW VOLTAGE WIRING. HVAC VAV BOX • • • • • • • SEE HVAC PLAN DUCTWORK, DIFFUSERS • • • SEE HVAC PLAN THERMOSTATS • • • • SEE HVAC PLAN EXHAUST FAN • • • • CLEAR ANODIZED ALUM. WHERE INDICATED SPECIALTY ANTI THEFT SYSTEM • • • • • • • G.C. TO COORDINATE WITH INSTALLER FIRE EXTINGUISHERS • • • LOCATE AND INSTALL PER FIRE DEPT. REQ. CAMERA SYSTEM • • • • G.C. TO PROVIDE CONDUIT RESPONSIBILITY SCHEDULE FOR ANY TENANT FURNISHED ITEMS THE GENERAL CONTRACTOR SHALL SCHEDULE NO LESS THAN THREE (S) WEEKS FOR DELIVERY FROM PACIFIC SUNWEAR. GENERAL CONTRACTOR SHALL NOTIFY PACIFIC SUNWEAR OF SCHEDULE. ITEM STOREFRONT FURNISHED 1 INSTALLED I REMARKS GLAZING • • • • • • • MTL. STUDS BY LANDLORD NEUTRAL STRIP • • • EXISTING STOREFRONT SIGN • • • • COORDINATE INSTALLATION W/ SIGNAGE CONT. CONTINUOUS REVEALS • • • • CLEAR ANODIZED ALUM. WHERE INDICATED MALL FLOORING (IF REQ.) • • • CONTACT MALL MANAGER FOR SPECIFICATIONS GLAZING CHANNELS • • • • SEE DOOR SCHEDULE ROLL -UP GRILLE • • • • SEE LIGHT FIXTURE SCHEDULE SIGN CANOPY • • • METAL STOREFRONT PANELS • • • • INCLUDING REVEALS CASH WRAP • • LIGHT FIXTURES • • • SEE SCHEDULE STEREO SYSTEM • • • • G.C. TO RUN CONDUIT & PROVIDE PULL STRING MERCHANDISING HDW. • • • FITTING RM. ACCESSORIES • • SEAT TAG HOOKS, DOOR FRAMES SIGNS PAINT • • SCANNERS, TAG GUNS • • COMPUTER SYSTEM • • SALES AREA DEMISING WALLS • • 6/i/06 • • • MTL. STUDS BY LANDLORD GYP. BD. @ DEM. WALLS • • • IF NOT EXIST. OR UNSUITABLE(TENANT SIDE ONL` INTERIOR PARTITIONS • • • METAL FURRING • • • • GYP BD. SOFFITS & FRMG • • • G.C. TO BOLT TO FLOOR DOORS & HARDWARE • • • SEE DOOR SCHEDULE MIRRORS • • • SEE LIGHT FIXTURE SCHEDULE FLOOR FIXTURES • • WALL STANDARDS • • • FIRE TREATED IF REQUIRED. CASH WRAP • • LIGHT FIXTURES • • • SEE SCHEDULE STEREO SYSTEM • • • • G.C. TO RUN CONDUIT & PROVIDE PULL STRING MERCHANDISING HDW. • • • FITTING RM. ACCESSORIES • • SEAT TAG HOOKS, DOOR FRAMES SIGNS PAINT • • SCANNERS, TAG GUNS • • COMPUTER SYSTEM • • INT. "D.E.M.O." SiGN • • BY SIGN CONTRACTOR METAL SLATWALL • • ACCESSORY AND BACK / WRAP AREAS FITTING ROOM WALLS • • FITTING ROOM BENCH • • WOOD BASE •' • FURNISHED BY SANTA FE WOOD FLOORING • • ON PLATFORM TILE FLOORING • • WALLCOVERING • • WOOD CROWN MOLDING & BACKING • • FURNISHED BY SANTA FE DOOR KICK PLATE • • STOCK ROOM VCT FLOORING SHEET: • 6/i/06 • NONE RUBBER BASE • • PROJECT No.: OFFICE DESK • DEM06024 • FILE CABINET • • SAFE • • G.C. TO BOLT TO FLOOR LOCKERS • • G.C. TO ASSEMBLE. LIGHT FIXTURES • • SEE LIGHT FIXTURE SCHEDULE STANDARDS & BRACKETS • • SHELVING • • FIRE TREATED IF REQUIRED. BULLETIN BOARD • • PAINT • • 1" x 4" WOOD STRIPS • • ROLLING SHELVING • • NEW MOP SINK • NEW DRINKING FOUNTAIN • 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. �u V L r CCQ^ OVO �- w W , to = p W ft Z V WJ O O L D ._ FM u O in E O m = W VOCLM vA (r v) v) _ cc W W z Z W 0 Z P D Z A wqpv v�l+r!kn AM 1A Z 0 , ao :r N N CL N o 00 o rn a c 00 30, eo � _ uL ro N cin O0 � N Q co U6 O 0) cri in Ln V, 41 d � t V O 0 E c D 1LJN 5 '06 DATE: SHEET: 6/i/06 SCALE: NONE DRAWN BY: S P3 JDD PROJECT No.: DEM06024 <1 tu Z ::ii X L LIMITS OF DEMOLITION UNDER THISIS SCOPE -------- --- ---- ------------------------------ - v!W& a-, I KEYED NOTES 0 EXISTING MALL NEUTRAL PIER TO REMAIN. OEXISTING TENANT DEMISING PARTITION TO REMAIN. OEXISTING REAR SERVICE DOOR TO REMAIN. 0 EXISTIN6 INTERIOR DOORS TO BE REMOVED IN THEIR ENTIRETY. THESE LINES ARE SHOWN DASHED. OEXISTIN6 INTERIOR PARTIONS TO BE REMOVED IN THEIR ENTIRETY. THESE LINES ARE SHOWN DASHED. OEXISTIN6 MECHANICAL DUCTS 4 EQUIPMENT. SEE MECHANICAL PRAAIN69 FOR DETAILS. 0 EXISTIN6 STOREFRONT, STOREFRONT 6LAZIN6, AND ROLL -UP 6RILLE TO BE REMOVED IN THEIR ENTIRETY. OEXISTIN6 ELECTRICAL EQUIPMENT. SEE! ELECTRICAL DRAWINGS FOR DETAILS. (D REMOVE EXISTIN6 WALL FINISH DOAN TO ORIGINAL DRYWALL SURFACE OF DEMISING WALL. ff-6: PANELIN6, WALL COVERING, SLATPSIALL, FURRING, ETC. 8 REMOVE EXISTIN6 FLOORING MATERIALS FROM EXISTIN6 CONCRETE SLAB, 55. TILE, CARPET, TACK STRIP, ETC. SCRAPE AND OR 6MINV 5LA5 TO A SMOOTH FINISH READY TO RELIEVE NEW FLOOR FINISHES AS DESCRIBED IN THESE PLANS. 0 REMOVE EXISTIN6 LAY -IN CEILINO GRID SYSTEM IN ITS ENTIRETY, REMOVE ALL MEMBERS FROM PREVIOUS STRUCTURES ABOVE CEILIN6 AREA (E.6. OLD BRACING, TIE AIRES, OLD CONDUITS, ETC.) 0 EXISTIN6 50" OPEN 104EE, ANGLE TRUSS 12" WIDE @ +15'-0" TO REMAIN. 13 EXISTIN6 PLUMBING FIXTURES AND 6RA5 BARS TO BE REMOVED IN THEIR ENTIRETY. 14 EXISTIN6 4" SPRINKLER MAIN 0 15'-4" TO REMAIN. 15 EXISTIN6 5"X5" STEEL TUBE COLUMN TO REMAIN. @ EXISTIN6 SOFFIT TO BE REMOVED IN ITS ENTIRETY. (D EXISTIN6 4" SPRINKLER LINE 4 BRANCHES a TO REMAIN. GENERAL NOTES 1. REMOVE ALL ITEMS AS INDICATED ON PLANS. 2. CARE SHALL BE TAKEN DURING DEMOLITION SO AS NOT TO PAMA&E OR. ALTER ANY EXISTIN6 STRUCTURAL MEMBERS. THE ARCHITECT AND 01104NER SHALL SE NOTIFIED IMMEDIATELY IF ANY PAMA6F_ OCCURS OR 19 DISCLOSED DURING DEMOLITION. 5. IN ALL WALLS AND CEILIN65 THAT ARE REMOVED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR GAPPING ANY ELECTRICAL, PLUMBING, 6A5 LINES AND MECHANICAL DUCTWORK THAT 15 DISCLOSED AND NOT SCHEDULED FOR REUSE. REROUTE AND CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR ADJACENT BUILDING AREAS THAT ARE NOT IN THIS CONTRACT. 4. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT 15 TO BE REMOVED SHALL BE DISCONNECTED AT SOURCE AND REMOVED. S. ALL 6AS, WATER AND DRAIN LINES SUPPLYING EQUIPMENT THAT 15 TO SE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED ABOVE CA!ILIN& OR BELOW FLOOR, IF CONTINUITY OF SYSTEM MUST BE MAINTAINED FOR USE BY ADJACENT AREAS, CONTRACTOR SHALL REROUTE, AS NECESSARY, TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.) 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING FROM THE SITE, ALL RUBBLE AND DEBRIS CAUSED BY DEMOLITION, AND PI5POSIN6 OF IT IN A PROPER MANNER. 'I. DEMISING PARTITION WORK TO BE REMOVED SHALL BE PERFORMED IN ACCORDANCE WITH LANDLORD'S CRITERIA. ALL INTERIOR DEMOLITION WORK TO BE BY TENANT'S 6.C. 5. REMOVE OR RELOCATE ANY SPRINKLI!R/SI!V4ER/PLUM5IN6 LINES, AS REQUIRED, IN FIELD PER LANDLORD'S ANP/OR LOCAL AUTHORITY APPROVALS. al. GENERAL CONTRACTOR TO COORDINATE WITH THE OWNER AND ARCHITECT AS TO THE DISPOSITION OF ALL ITEMS TO BE REMOVED. 10. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL CEILIN&S, WALLS AND FLOORS, AS REQUIRED, TO RECEIVE NEW FINISHES. (6.C. TO MAINTAIN I -HOUR FIRE RATED CONSTRUCTION THROUGHOUT TENANT'S SPACE WHEN RMOUIREP). 11. COORDINATE CONSTRUCTION SCHEDULE AND BARRICADE WITH MALL MANAGEMENT. G.C. DEMOLITION SUMMARY GENERAL CONTRACTOR ANP/OR SUBCONTRACTORS SHALL REVIEW THE EXISTIN6 FACILITY TO DETERMINE THE EXTENT 012 DEMOLITION REQUIRED TO INSTALL THE NEW WORK. A WRITTEN OUTLINE OF ALL REQUIRED DEMOLITION SHALL BE SUBMITTED TO THE OWNER DESCRIBING THE POLLOAIN(S (BUT NOT LIMITED TO). 1, CONDITION OF EXISTIN6 POWER PANELS AND TRANSFORMERS; FEASIBILITY FOR RELOCATION AND REFUR51SHIN6, OR NEED FOR REPLACEMENT DUE TO AGE OR EXISTIN6 CONDITION. 2, CONDITION OF EXISTIN6 SHEETROCK ON EXISTIN6 DEMISING 104ALLS, AND RECOMMENDATION OF WHETHER TO REMOVE EXISTIN6 OR. REUSE TO DE DETERMINED IN FIELD. 5- CONDITION OF EXISTIN6 MECHANICAL SYSTEM; FEASIBILITY 010 REUSIN6, RELOCATION, OR RE- FURBISHING EXISTIN6 EQUIPMENT AND DUCTWORK; AND RECOMMENDATION OF REPLACEMENT, IF NECESSARY, PRIOR TO BID. 4. SUMMARIZE RECOMMENDATIONS FOR REUSE OF EXISTIN6 MATERIALS, EQUIPMENT AND ACCESSORIES, ONCE REFURBISHED TO A LIKE -NEW CONDITION, ITEMIZE THE CREDIT TO THE CONTRACT. 5. ANYUNNOTr=V EXISTIN6 CONDITION WHICH CONFLICTS WITH THE PROJECT REQUIREMENTS AND MAY REQUIRE MODIFICATION, RELOCATION OR REMOVAL TO COMPLETE THE PROJECT SHALL BE INPENTIFIEr.> $0 THE NECESSARY DRAWING REVISIONS MAY BE INCORPORATED INTO THE PROJECT ROUIREMENTS. 6. IN ADDITION TO THE ABOVE, REFER TO GENERAL DEMOLITION NOTES INDICATED ON SHEET 5P-1, r.>IVI5I0N 2 - DEMOLITION / BUILDING ALTERATION. LIMITS OF DEMOLITION UNDER THIS SCOPE _J _J r T q_J L L L(5) :2" DOWN To I SPRINKLER LINE! LENGTH 14 I& i is I6 OF SPACE o I I 10 7L L D 10 I �___ -__ ------------------------------------ ---------------------------------------- t ----------------------------------- ---------------------------------- ------------------------ A.7, BULKHEAD ®12' -II 5/4" 26" JOIST SPACED EVERY METAL PAN DECK @ I1' -2"I I I I I 11 I I MALL t a IT 4" SPRINKLER LINE @ 10 11 r - — — — — — — — — — LIL � � I i L ------ --------------- -------------- J_L_ -4 - - - - - - - W/ - - - - - - ------------- - - - - - - - - - - - - - - - - - - - - I_ L - - - - - --- - --- - - - - - - - - - - - - - - - NA - - - - - - - - - - - - - - - - - !. - �/ - - �_ - - - - - - - - - - - - - - \_� - - - - - - - - W/-- J11- 0 5'-O"x 6'-0" PLENUM& 121-011 U ADJACENT TENANT _� J2 DEMOLITION PLAN SCALE: 1/4" = 1'-0" NOTE! 11 NOTE: NOTE: A 6.C. TO REFER TO PA61ES MI 0 M2 I (S.C. TO REMOVE ALL MATERIAL AND REMOVE ALL ABANDONED UTILITIES, REGARDING REUSE OR REMOVAL OF EQUIPMENT NOT TO BE REUSED. INCLUDIN& DUCTWORK ENTIRELY, HVAC EQUIPMENT 4 DUCT. BACK TO POINT OF ORIGIN. Z L) e lexA., off to THE TERANTITIMANT CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. ,TENANT SHALL COMMENCE TENANM WORK AS DIRECTED BY LANDLORD IN THE MANNER PROVIDED IN THE LEASE ONLY AFTER RECEIVING APPROVED WORKING DRAWINGS AND *HALL DILIGENTLY CARRY SAME TO COMPLETION By THE DAY SPECIFIED IN THE LEASE. ALL REQUIRED BUILDING AND OTHER PERMITS IN CONNECTION WITH THE CONSTRUCTION AND COMPLETION OF THE TENANT'S WORK IS THE SOLE RESPONSIBILITY OF THE TENANT! TENANT'S CONTRACTOR(S). ALL DEMO To LIE COORDINATED WITH LANDLORD'S ON SITE FIELD MOT. TO INSURE 140 DISRUPTION OF MALL COMMON AREA ACTIVITIES. ANY EXISTING EQUIPMENT OR BUILDING COMPONENTS NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY. PAIRS REQUIRED TO ROOFING SYSTEMS) OR OTHER PARTS OF THE CENTER MUST BE COMPLETED TO LA1,IOLORO*S SPECS, TENANT'$ REUSE OF ANY EXISTING CONSTRUCTION, FINISHES, EQUIPMENT, ELECTRICAL, PLUMBING AND "VAC SYSTEMS) IS CONDITIONAL UPON THE NEW USE BEING APPROPRIATE FOR EXISTING EXISTING ITEM(S) AND TENANT COMPLETING ANY NECESSARY REPAIR OR REFINISHING REQUIRED TO BRING ITEMS) TO A -NEW-UKE- STATUS. ■ TENANT CONTRACTOR 18 RESPONSIBLE TO COMPLY WITH ALL MALL RULES AND REDS PER TENANT CRITERIA HANDBOOK AND AS INSTRUCTED BY LANDLORD'S ON SITE MGT. NCOORIXNATX)N OF CONSTRUCTION BARRICADE AND CONSTRUCTION TRASH DUMPSTER SHOULD BE SCHEDULED WITH ON SITE MANAGEMENT. TENANT SHALL NOT MAKE ANY ROOF PENETRATIONS WHATSOEVER OTHER THAN THOSE SPECIFICALLY PERMITTED IN WRITING BY LANDLORD. NOTHING 13 PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK YOU MUST ATTACH To TOP CHORD OF JOIST OR STRUCTURAL STEEL, EXISTING ABOVE THE TENANTS SPACE, THE MALL'S CONTRACTOR MUS30E UTILIZED FOR ALL MOIXFICATION* To THE SPRINKLER SYSTEM A ENANT"S COST. THE SPRINKLER SYSTEM MUST BE FULLY CHARGED AND OPERATIONAL PRIOR TO CONTRACTOR DOING OFF SITE. ANY FLOOR PENETRATIONS THROUGH CONCRETE $LASS MUST BE CORE - BORED OR SAW CUT, SLEEVED, SEALED, FIRESTOPPED AND WATER- PROOFED. ALL PIPING SLEEVES SHALL EXTEND!- IN HEIGHT. ANY MASONRY OPENINGS TO BE IN -FILLED, MUST BE DONE WITH MATERIALS To MATCH EXISTING EXTERIOR Of BUILDING. MATERIALS MUST Of APPROVED BY MALL MANAGEMENT. MALL PATCHING MUST BE LEVEL AND FLUSH WITH FASTING CONCRETE FLOOR. MALL WETI KITCH5kr FOOD PREP AREAS ON UPPER LEVELS MUST BE WATERPROOFED, USING A 30 MIL POLYETHYLENE CLEAVAGE MEMBRANE BEFORE FINISHED FLOOR IS APPUE06 TENANT MUST DEMONSTRATE WATERTIGHT INTEGRITY OF MEMBRANE To LANDLORDI FIELD REP. LIMITS OF DEMOLITION UNDER THIS SCOPE I CORRIDOR] REMOVE PORTION OF EXISTIN6 DEMISING PARTITION—, - - - - - - - - - - - - - - - - - --- ---4--1-----.__..--_._. ---------- I ---------I I TJQI ml I r---7 IL----- I & L _J L ----------- --------------- -- ----- ----------------- ------------------- I I ,r-�{iii iliF�`'-��--- i i „ I I a II 15 15 0 F -1 4 i i i_� --� Li J L JJ i i ,� li i i I I n rr J L IT_J L _T1 �_J L_ U I---- — — — _AJ d G5 �-- I I q _� 6 I `` � , � Q , • L -------- 14,_]_ t I DEMOLITION PLAN CONT'D SCALE: 1/4" = 1'-0" WCA r -J LIMITS OF DEMOLITION it UNDER THIS SCOPE 2246 .0PKRIG_H'L NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. W Son LIE Go C =Qn cc 0UJ J 1=0 Cs■ LLm Go C *4 0 z 10 0 LN CuM01111111110111Iwo E0Mc Goo on M %A N V) 1A Z SHEET. Z 6/I 106 SCALE: DRAWN BY: JOD D1 0 PROJECT No.: PEY0602.4 0 Vf (14 CIL 8 00 + LL. fV In 00 M 0 C: a 0 r4 'qt E DO 0 0 Z U 00 In mo' C.4 tt Ln + e C a VS42 Cc JUN 5 '06 DATE: SHEET. 6/I 106 SCALE: DRAWN BY: JOD D1 PROJECT No.: PEY0602.4 B C D tlll'-7 3/4" (FIELD VERIFY) 3'-4 3/4" 3o' -O" 30'-0 " 7'-2"1-7111,3'-4" '1" 3'-4" *7";V-9 1/4"..(28) STANDARDS ® 24" O.G. = 54'-O" 1 1 GYP. BD PITTIN& I NEW DEMISING ROOM P RTITIONS TO PARTITION BY ADJACENT I IO' -O" ( ,P.) SEE TYP. ( LANDLORD—. n a DETAIL TENANT I ., ,717 IIR F4 FF -1 u / T T E E 12 TYPICAL A7 STANDARD D-3 D-2 m f? Ele - c?r 3:_8:: 3:_2:. _3:: 2._8:. 1_3:. 2:_8.. 011 F.O. F.O. P.O. LOCATION OF ELECTRICAL / DATA STUB UPS. LOCATION OF CASH SALES AREA DATA STUB UPS. I WRAP 12 TYPICAL STANDARD I EXIST. DEMISIN6 PARTITION ■THE TENANT SHALL DO UMEN SMEETA FOR VERIFYING THAT THESE CONSTRUCTION DOCUMENTS MEET ALL ADA STANDARDS AND DIMENSIONED DOOR SCHEDULE I REQUIREMENTS. KEY DESCRIPTION � O EXISTING ONE-HOUR DEMISIN6 ITION: EXISTING METAL �� ENTRY GRILLE: I .NO FIXED OR MASS MERCHANDISING IN SHOW WINDOW AREA(S). TUDS 4 DRYWALL. TENANT G. SHALL PATCH AND REPAIR NOTE: v pOppp NOTE: EXAMPLE: SLAT WALLS, ETC... � N DEMISIN6 PRTITIONS MUST BE OF CLEAR ANODIZED HEAVY DUTY 3" BOTTOM BAR AND 6UIDES, ADJUST STOPS 50 REFER TO SPS SHEET FOR DOOR NOTES. 5M TH TO ACCEPT W FINISHES. wZL n _{ — 12 16HT TO DECK ABOVE. I �r !�n cr NEW D ISIN6 PA (TION: EXISTING METAL STUDS BY L.L. ® DOOR TO REMAIN UN -LOCKED DURING BUSINESS HOURS" LETTERS SHALL BE MIN. i" ---... I infx'�E A7 HIGH ON A CONTRASTING 5AGK6ROUND. (WHEN REQUIRED BY CODE) TENANT SIDE ONLY UP TO DECK ABOVE. TAPE 4 SAND �5 SMOOTH TO RELIEVE FINISH. PER U.L. P5616N NO. U -465D-2 FITTING ROOM DOOR: TYPICAL NEW 2'-6" x 5'-0" x 1 3/4" SOILD GORE FITTING ROOM DOOR W/ GLASS INSERT, DOORS, O Its. NEW PITTING ROOM PARTITION: 6" X IS &A. METAL STUD JAM85, AND BUTTS SUPPLIED BY F.G. !LEVER TYPE LOCKING HARDWARE SUPPLIED BY STANDARD Cj O FRAMING ® 16" O.G. UP TO 10'-0" W/ 5/8" TYPE 'X' GYP. BD. OWNER. 64. TO INSTALL. (NOTE: G.G. IS TO INSTALL, ON THE SALES AREA SIDE, STEEL h ��3i BOTH SIDES. TAPED, AND SAND SMOOTH TO RECEIVE GOAT HOOK IN THE CENTER OF THE DOOR, I" DOWN FROM THE TOP TO THE TOP OF Ir Q " FINISH. �4_ D C _ / NOT USED O ROOM DOOR: (H.C) EN NEW 3'-0" x 5'-0" x 1 3/4" SOILD GORE. FITTiN6 ROOM DOOR W/ 6LASS INSERT. " DOORS, JAMBS, AND BUTTS SUPPLIED BY F.G. LEVER TYPE LOCKING HARDWARE NEW INTERIOR PARTITION: 3-5/8" X 20 &A. METAL STUD SUPPLIED BY OWNER. 6.C. TO INSTALL. (NOTE: 6.G. 15 TO INSTALL, ON THE SALES O FRAMING s 16" O.G. TO +8'-O" Al 5/8" TYPE 'X' GYP. BD. AREA SIDE, STEEL GOAT HOOK IN THE CENTER OF THE DOOR, I" DOWN FROM THE BOTH SIDES, TAPED, 4 SAND SMOOTH TO RECEIVE NEW TOP TO THE TOP OF FLANGE. 3'-2" FINISHED OPENING. FINISHES. 4 SALES AREA TO HALLWAY: I � AS AS BUTTS AND 5/5 LEVER TYPE PASSAGE SET WITH SELF GLOSIN6 DEVICE, 10" HIGH FURRIN6 s 24" O.G. UP TO 13'-6" A.F.F. W/ 5/8" TYPE 'X' BRUSHED STAINLESS STEEL KICK PLATE 4 DOOR BUMPER. (DOOR, FRAME, GYP. BD, ONE SIDE, TAPED, 4 SANDED SMOOTH TO HARDWARE, AND INSTALLATION BY TEN. (S.C.) RECEIVE NEW FINISHES. gig HALLWAY TO STOCKROOM: O NEW INTERIOR PARTITION: 3-5/8" X 20 &A. METAL STUD NEW 3'-0" x 7'-0" x 1 3/4" HOLLOW METAL FLUSH DOOR 4 FRAME. 1-1/2" PAIR H.D. FRAMING ® 16" O.G. TO +8'-0" W/ 5/8" TYPE 'X' GYP. BD. BUTTS AND 5/5 LEVER TYPE PAS5A6E SET WITH SELF GLOBIN& DEVICE 4 FLOOR BOTH SIDES, TAPED, 4 SAND SMOOTH TO RECEIVE NEW STOP. (DOOR, FRAME, HARDWARE, FLOOR STOP, AND INSTALLATION BY TEN, G.G.) RECESSED MOUNTED FINISHES. ILLUMINATED EXIT SIGN STOCKROOM TO TOILET ROOM: D-6 O NEW STOREFRONT PARTITION: POWDER COATED METAL 4 NEW 3'-0" x 6'-8" x 1 3/4" SOLID GORE WOOD DOOR 4 HOLLOW METAL FRAME. 1-1/2 ABOVE. SEE SHEET E2 3/4 M.D.P. 4 5/8 TYPE 'X GYP. BD. OVER 3 5/8' X PAIR BUTTS, CLOSER, 9/5 LEVER TYPE PRIVACY LOGKSET 4 DOOR BUMPER. ( DOOR, 0 A 209a. MTL. STUD FRAMIN6 ® 1611 O.G. FRAME, HARDWARE, AND INSTALLATION BY TEN. 6.G.) E REAR SERVIC"XIT DOOR: D-7 M •. .• .. NEW ONE-HOUR PARTITION. X 20 6A. METAL STUD " - EXIST. 3'-O" x 7'-O" HOLLOW METAL DOOR 4 FRAME W/ NEW PANIC HARDWARE oz FRAMING ® 16" O.G. W/ 5/5" TYPE 'X' GYP. BD EACH SIDE SUPPLIED BY OWNER. FIRE RATED SELF CLOSING DOOR ASSEMBLY. TIGHT FITTING, 01 Y_ "3 FULL HE16HT TO DECK ABOVE PER U.L. DESIGN NO. U-465 SMOKE DRAFT CONTROL DEVICE IS REOUIRED. PROVIDE A DOOR CLOSER, SMOKE J neo 6ASKETS AS REQUIRED G.C. TO PAINT INSIDE 4 OUTSIDE OF DOOR 4 FRAME. HINGES TO HAVE NON -REMOVABLE PINS. PROVIDE DOOR VIEWER AND LABEL REAR OF DOOR ■LANDLORD IS RESPONSIBLE FOR METAL STUDS ONLY IN DEMISING WALL. W; c Amo : i Lilt5 -10 I/4" TENANT IS RESPONSIBLE FOR 1 HOUR FIRE RATED FINISH. MALL NEW WALL CONSTRUCTION IS TO BE SUPPORTED FROM TOP CHORD OF STRUCTURAL JOIST(S) AND NOT FROM METAL DECK ABOVE. LOCATION OF ELECTRICAL / DATA STUB UPS. LOCATION OF CASH SALES AREA DATA STUB UPS. I WRAP 12 TYPICAL STANDARD I EXIST. DEMISIN6 PARTITION ■THE TENANT SHALL DO UMEN SMEETA FOR VERIFYING THAT THESE CONSTRUCTION DOCUMENTS MEET ALL ADA STANDARDS AND DIMENSIONED DOOR SCHEDULE FLOOR PLAN REQUIREMENTS. KEY DESCRIPTION DATE: O EXISTING ONE-HOUR DEMISIN6 ITION: EXISTING METAL �� ENTRY GRILLE: .J 0001 .NO FIXED OR MASS MERCHANDISING IN SHOW WINDOW AREA(S). TUDS 4 DRYWALL. TENANT G. SHALL PATCH AND REPAIR NOTE: v pOppp NOTE: EXAMPLE: SLAT WALLS, ETC... � N DEMISIN6 PRTITIONS MUST BE OF CLEAR ANODIZED HEAVY DUTY 3" BOTTOM BAR AND 6UIDES, ADJUST STOPS 50 REFER TO SPS SHEET FOR DOOR NOTES. 5M TH TO ACCEPT W FINISHES. FIRECODE " " SHEETROGK, TAPED AND Q OR o .TENANT SHALL FURNISH AND INSTALL THE MALL'S FLOORING FROM INSTALLED BY OWNER'S SOURCE.) O.C. SHALL POST 516N ON DOOR STATING: "THIS SEALED AI 16HT TO DECK ABOVE. I �r !�n cr NEW D ISIN6 PA (TION: EXISTING METAL STUDS BY L.L. ® TENANTS LEASE UNE TO THE REAR OF THE MOST PROMINENT STOREFRONT ELEMENT (CLOSURE LINE). NO RUBBERMNYL BASE PERMITTED IN RETAIL/SALES AREAS. : HARD SURFACE FLObRiNG, Ir MARBLE, TILE, WOOD, ETC. MUST BE USED MINIMUM THE FIRST V-0" INTO TENANT SPACE. ■ A METAL EDGE TERRAZZO STRIP MUST BE USED AT TRANSITIONS BETWEEN HARD SURFACE MATERIALS AND OTHER FLOOR MATERIALS. . USE OF VINYL OR PLASTIC TRANSITION STRIPS IS PROHIBITED. ALL TRANSITIONS MUST BE SMOOTH FLUSH. ■ EXPOSED CONCRETE OR BLOCK WALLS WILL NOT BE PERMISSIBLE IN SALES AREAS. CONCRETE OR BLOCK WALLS NOT CONCEALED BY FIXTURES MUST BE COVERED WITH GYPSUM BOARD BY TENANT. ADJACENT (54) STANDARDS 0 24" E d:: z:_`"i NEW DEMISINGI MALL BULKHEAD PARTITION BY ABOVE. LANDLORD NEW MALL NEUTRAL tt PIER BY LANDLORD IE I 4), 1/2" CLEAR TEMPERED I GLAZIN6 DISPLAY I I ® to A.F.F. 1 1 1 m I A5 I I DISPLAY PLATFORM W/ WOOD FINISH I PROVIDE SIGN OVP DOOR STATING: 'THS DOOR TO F14MAIIN UNLOCKED DURINGr i -j AREA OF TRENGHIN6 BUSM88, HOURS ' LETTERS TO T' HIGH 1 ON A CONTRASTING BACKGROUND. I 11 I 11 I REa'D FOR ANTI -THEFT EXISTING CONCRETE FLOOR SURFACE PREPARE FOR INSTALLATION OF NEW 0 FLOORING MATERIALS AS INDICATED IN THESE PLANS. SEE SHEET SPI FOR ISALESAREA1 12 TYPICAL A7 STANDARD ANTENNA VERIFY 51ZE :,,..,.,;....,."._,.,.,7EXIT WITH OWNER .D ILLUMINATE1 II I 1 2 ID 9 516N ABOVE. SEE i SHEETE2. i II i I I A5 L II -� CENTERLINE or- ROLL-UP FROLL-UP GRI LLE I L_ ' J I I MALL � I LEA5E LINE DISPLAYI - D15PLAY PLATFORM �. ® 10" A.F.F. 1 1 W/ WOOD FINISH m I I 1 MALL BULKHEAD m A\BOVE. E I �- I 1 1 1 1 I o I EXIST. MALL 1 EXIST. DEMISIN6 A r — NEUTRAL PIER PARTITION I A4 IQ SCALE: 1/4" = 1'-0" A till' -7 3/4" (FIELD VERIFY) UJ 4 3/4"34'-7 I/4" x I NLI (21) STANDARDS® 16" O.G. I f I I I Q I i I I - I I i NEW DEMISIN6 NEW DEMISIN6 MALL ! PARTITION BY ADJACENT PARTITION BY ! - SERVICE L L TENANT L.L. CORRIDOR nN.I.G. �,• •� .:,, •iti .r,� �� ., �.t ,a" : O i I I I I I I I I i I I I I I I I Lf __j :: (-- } AUDIO 4 3 _. -._. - - - - - _ !L. Q ELEG. EQUIP. SHELF a Q 5EE BHT. EI - fu NEW HANDICAP GRAB �- - - - - - - -` > !_ d BARS W/ NEW PLUMBING MANAGERS DESK I r FIXTURES (TYP.) _ ..._... STOCKROOM - - - - - .� NEW - - -� A s DRINKING O FOUNTAIN If - - - - SHOE m 48" X 30" E - RACK CLEAR FLOOR - - - - — SPACE (TYP.) � Atf T 911 LL. EXIST. DEMI5IN6 0 PARTITION - L L m ; T 56" X 60" CLEAR " U1I I I I ( - GLR� D- _ - FLOOR SPACE (TYP.) - D H W RM — -- ILLUMINATED D ILLUMINATED z EXIT 516N D EXIT 516N D ABOVE. SEE A- - - SEEPitt- n I D -T SHEET E2 HALLWAY SHEET E2 - 4 � Ul D-4 — .._. ------------- _ n �y EXIST. DEMISIN6 ° A ADJACENT TENANT PARTITION A 121-61/21, 12'-8" 5" h'_O" ------------- J tlll'-7 3/4" (FIELD VERIFY) DIMENSIONED FLOOR PLAN CONT'D _ SCALE: 1/41: 11_01: _ i 2 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without Ilmitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 40 V C � cu oo M 0 V W _ ' LLI Z a� o be Ip 3:ZT IIIIS a o am E Um %Ic= V! N Vf Vf Q ac W W Z 0 Z W Z 5 H Z O 0 J W 0 W Z 0 H Z W WALL LEGEND DOOR SCHEDULE 4/ M KEY SYMBOL DESCRIPTION KEY DESCRIPTION DATE: O EXISTING ONE-HOUR DEMISIN6 ITION: EXISTING METAL �� ENTRY GRILLE: .J 0001 6/1/06 TUDS 4 DRYWALL. TENANT G. SHALL PATCH AND REPAIR METRO' MANUALLY OPERATED, STRA16HT PATTERN, CURTAIN OVERHEAD ROLLIN6 v pOppp ISTIN6 GYP. BD. PER U . DESIGN NO. U-465 ON TENANT 6RILLE, W/ "BEST" LOCKS, KEYED AT EXTERIOR, THUMBTURNS ON THE INTERIOR. � N 5 E ONLY FULL HE16HT O DECK ABOVE. TAPE, 4 SAND CLEAR ANODIZED HEAVY DUTY 3" BOTTOM BAR AND 6UIDES, ADJUST STOPS 50 �Mo 5M TH TO ACCEPT W FINISHES. THAT GRILLE ROLLS -UP COMPLETELY INTO STOREFRONT CANOPY. (FURNISHED AND Q OR o rn z j5O INSTALLED BY OWNER'S SOURCE.) O.C. SHALL POST 516N ON DOOR STATING: "THIS In� I �r !�n cr NEW D ISIN6 PA (TION: EXISTING METAL STUDS BY L.L. ® DOOR TO REMAIN UN -LOCKED DURING BUSINESS HOURS" LETTERS SHALL BE MIN. i" LnV+ I infx'�E 6.G. SHA P (1) LAYER 5/8" TYPE"X" GYP. BD. HIGH ON A CONTRASTING 5AGK6ROUND. (WHEN REQUIRED BY CODE) TENANT SIDE ONLY UP TO DECK ABOVE. TAPE 4 SAND �5 SMOOTH TO RELIEVE FINISH. PER U.L. P5616N NO. U -465D-2 FITTING ROOM DOOR: NEW 2'-6" x 5'-0" x 1 3/4" SOILD GORE FITTING ROOM DOOR W/ GLASS INSERT, DOORS, Its. NEW PITTING ROOM PARTITION: 6" X IS &A. METAL STUD JAM85, AND BUTTS SUPPLIED BY F.G. !LEVER TYPE LOCKING HARDWARE SUPPLIED BY O FRAMING ® 16" O.G. UP TO 10'-0" W/ 5/8" TYPE 'X' GYP. BD. OWNER. 64. TO INSTALL. (NOTE: G.G. IS TO INSTALL, ON THE SALES AREA SIDE, STEEL E 0 ��3i BOTH SIDES. TAPED, AND SAND SMOOTH TO RECEIVE GOAT HOOK IN THE CENTER OF THE DOOR, I" DOWN FROM THE TOP TO THE TOP OF Ir Q FINISH. FLANGE. 2'-8" FINISHED OPENING. C _ / NOT USED O ROOM DOOR: (H.C) EN NEW 3'-0" x 5'-0" x 1 3/4" SOILD GORE. FITTiN6 ROOM DOOR W/ 6LASS INSERT. " DOORS, JAMBS, AND BUTTS SUPPLIED BY F.G. LEVER TYPE LOCKING HARDWARE NEW INTERIOR PARTITION: 3-5/8" X 20 &A. METAL STUD SUPPLIED BY OWNER. 6.C. TO INSTALL. (NOTE: 6.G. 15 TO INSTALL, ON THE SALES O FRAMING s 16" O.G. TO +8'-O" Al 5/8" TYPE 'X' GYP. BD. AREA SIDE, STEEL GOAT HOOK IN THE CENTER OF THE DOOR, I" DOWN FROM THE BOTH SIDES, TAPED, 4 SAND SMOOTH TO RECEIVE NEW TOP TO THE TOP OF FLANGE. 3'-2" FINISHED OPENING. FINISHES. 4 SALES AREA TO HALLWAY: NEW 3'-0" x7' -O" x 15/4" HOLLOW METAL FLUSH DOOR FRAME W/ 1-1/2" PAIR H.D. O NEW INTERIOR FURRING: 3-5/8" X 20 &A. METAL STUD BUTTS AND 5/5 LEVER TYPE PASSAGE SET WITH SELF GLOSIN6 DEVICE, 10" HIGH FURRIN6 s 24" O.G. UP TO 13'-6" A.F.F. W/ 5/8" TYPE 'X' BRUSHED STAINLESS STEEL KICK PLATE 4 DOOR BUMPER. (DOOR, FRAME, GYP. BD, ONE SIDE, TAPED, 4 SANDED SMOOTH TO HARDWARE, AND INSTALLATION BY TEN. (S.C.) RECEIVE NEW FINISHES. gig HALLWAY TO STOCKROOM: O NEW INTERIOR PARTITION: 3-5/8" X 20 &A. METAL STUD NEW 3'-0" x 7'-0" x 1 3/4" HOLLOW METAL FLUSH DOOR 4 FRAME. 1-1/2" PAIR H.D. FRAMING ® 16" O.G. TO +8'-0" W/ 5/8" TYPE 'X' GYP. BD. BUTTS AND 5/5 LEVER TYPE PAS5A6E SET WITH SELF GLOBIN& DEVICE 4 FLOOR BOTH SIDES, TAPED, 4 SAND SMOOTH TO RECEIVE NEW STOP. (DOOR, FRAME, HARDWARE, FLOOR STOP, AND INSTALLATION BY TEN, G.G.) FINISHES. STOCKROOM TO TOILET ROOM: D-6 O NEW STOREFRONT PARTITION: POWDER COATED METAL 4 NEW 3'-0" x 6'-8" x 1 3/4" SOLID GORE WOOD DOOR 4 HOLLOW METAL FRAME. 1-1/2 3/4 M.D.P. 4 5/8 TYPE 'X GYP. BD. OVER 3 5/8' X PAIR BUTTS, CLOSER, 9/5 LEVER TYPE PRIVACY LOGKSET 4 DOOR BUMPER. ( DOOR, 0 A 209a. MTL. STUD FRAMIN6 ® 1611 O.G. FRAME, HARDWARE, AND INSTALLATION BY TEN. 6.G.) a o REAR SERVIC"XIT DOOR: D-7 M •. .• .. NEW ONE-HOUR PARTITION. X 20 6A. METAL STUD " - EXIST. 3'-O" x 7'-O" HOLLOW METAL DOOR 4 FRAME W/ NEW PANIC HARDWARE oz FRAMING ® 16" O.G. W/ 5/5" TYPE 'X' GYP. BD EACH SIDE SUPPLIED BY OWNER. FIRE RATED SELF CLOSING DOOR ASSEMBLY. TIGHT FITTING, 01 Y_ "3 FULL HE16HT TO DECK ABOVE PER U.L. DESIGN NO. U-465 SMOKE DRAFT CONTROL DEVICE IS REOUIRED. PROVIDE A DOOR CLOSER, SMOKE J neo 6ASKETS AS REQUIRED G.C. TO PAINT INSIDE 4 OUTSIDE OF DOOR 4 FRAME. HINGES TO HAVE NON -REMOVABLE PINS. PROVIDE DOOR VIEWER AND LABEL REAR OF DOOR W; c Amo "DEMO" AND SPACE NO PER MALL REQUIREMENTS. ADJACENT (54) STANDARDS 0 24" E d:: z:_`"i NEW DEMISINGI MALL BULKHEAD PARTITION BY ABOVE. LANDLORD NEW MALL NEUTRAL tt PIER BY LANDLORD IE I 4), 1/2" CLEAR TEMPERED I GLAZIN6 DISPLAY I I ® to A.F.F. 1 1 1 m I A5 I I DISPLAY PLATFORM W/ WOOD FINISH I PROVIDE SIGN OVP DOOR STATING: 'THS DOOR TO F14MAIIN UNLOCKED DURINGr i -j AREA OF TRENGHIN6 BUSM88, HOURS ' LETTERS TO T' HIGH 1 ON A CONTRASTING BACKGROUND. I 11 I 11 I REa'D FOR ANTI -THEFT EXISTING CONCRETE FLOOR SURFACE PREPARE FOR INSTALLATION OF NEW 0 FLOORING MATERIALS AS INDICATED IN THESE PLANS. SEE SHEET SPI FOR ISALESAREA1 12 TYPICAL A7 STANDARD ANTENNA VERIFY 51ZE :,,..,.,;....,."._,.,.,7EXIT WITH OWNER .D ILLUMINATE1 II I 1 2 ID 9 516N ABOVE. SEE i SHEETE2. i II i I I A5 L II -� CENTERLINE or- ROLL-UP FROLL-UP GRI LLE I L_ ' J I I MALL � I LEA5E LINE DISPLAYI - D15PLAY PLATFORM �. ® 10" A.F.F. 1 1 W/ WOOD FINISH m I I 1 MALL BULKHEAD m A\BOVE. E I �- I 1 1 1 1 I o I EXIST. MALL 1 EXIST. DEMISIN6 A r — NEUTRAL PIER PARTITION I A4 IQ SCALE: 1/4" = 1'-0" A till' -7 3/4" (FIELD VERIFY) UJ 4 3/4"34'-7 I/4" x I NLI (21) STANDARDS® 16" O.G. I f I I I Q I i I I - I I i NEW DEMISIN6 NEW DEMISIN6 MALL ! PARTITION BY ADJACENT PARTITION BY ! - SERVICE L L TENANT L.L. CORRIDOR nN.I.G. �,• •� .:,, •iti .r,� �� ., �.t ,a" : O i I I I I I I I I i I I I I I I I Lf __j :: (-- } AUDIO 4 3 _. -._. - - - - - _ !L. Q ELEG. EQUIP. SHELF a Q 5EE BHT. EI - fu NEW HANDICAP GRAB �- - - - - - - -` > !_ d BARS W/ NEW PLUMBING MANAGERS DESK I r FIXTURES (TYP.) _ ..._... STOCKROOM - - - - - .� NEW - - -� A s DRINKING O FOUNTAIN If - - - - SHOE m 48" X 30" E - RACK CLEAR FLOOR - - - - — SPACE (TYP.) � Atf T 911 LL. EXIST. DEMI5IN6 0 PARTITION - L L m ; T 56" X 60" CLEAR " U1I I I I ( - GLR� D- _ - FLOOR SPACE (TYP.) - D H W RM — -- ILLUMINATED D ILLUMINATED z EXIT 516N D EXIT 516N D ABOVE. SEE A- - - SEEPitt- n I D -T SHEET E2 HALLWAY SHEET E2 - 4 � Ul D-4 — .._. ------------- _ n �y EXIST. DEMISIN6 ° A ADJACENT TENANT PARTITION A 121-61/21, 12'-8" 5" h'_O" ------------- J tlll'-7 3/4" (FIELD VERIFY) DIMENSIONED FLOOR PLAN CONT'D _ SCALE: 1/41: 11_01: _ i 2 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without Ilmitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 40 V C � cu oo M 0 V W _ ' LLI Z a� o be Ip 3:ZT IIIIS a o am E Um %Ic= V! N Vf Vf Q ac W W Z 0 Z W Z 5 H Z O 0 J W 0 W Z 0 H Z W 8 auk, c roe 4/ M ILA N DATE: CL O SHEET: .J 0001 6/1/06 SCALE: v pOppp DRAWN BY: � N in Cc �Mo Q OR o rn z j5O In� LnV+ I infx'�E r �5 MLS Its. C "aa E 0 ��3i O Ir Q auk, c roe DATE: SHEET: 6/1/06 SCALE: DRAWN BY: A 1 JDD PROTECT No.: VEM06024 SURFACE MOUNTED STANDARDS (TYP.) .... ... ... 5 -0" / GER.1 F.R.3 i FF. -R—. -21 [F.A.11 12 TYPICAL -HOOKS ®i HOOKS Al STANDARD A.F.F. +60" A.F.F. (TYP-) 4-AAY- A41 llk�'[ 14 3 G 6. E SIC7N 6 3/ ABOVE 2 2 I A TY ICAL 5T NP ARP ROUNDERS 4 -WAY 777F PL 1.2 TYPICAL A-? STANDARD MIRROR_ YNY411_14% IV �-MXISTI N6 DEMISING PARTITION E PLAN NOTE: ALL FINISH WOOD SHALL BE KILN -PRIMP, MILL DUALITY FINISH AND ALL WOOD SHALL RECEIVE111 A FIRE RETARDANT COATIN& OR. TREATMENT. NO WOOD OR OTHER COMBUSTABILM MATERIAL SHALL BE USED ABOVE ANY CMILINO. SURFACE MOUNTED STANDARDS (TYP.)- ISALES IZ-O" LONG METAL. SLATNALL BETWEEN STANDARDS--_ ADJACENT TENANT SURFACE MOUNTED STANDARDS (TYP.) LINE OF FLOOR, NVOLA A6 /---GONDOLA TRANSITION--,,,, 45" LONG X 56" HI(SH PULL-OUT H.C. TRANS- ACTION COUNTER- CUSTOM C�SH/ DISPLAY COUNTER. / METAL SLATNALLON BACKSIDE OF LOW I L ADJACENT TENANT PROVIDE DISABLED (Z;HEC,K9TANP 916NA6M AT GASH/WRAP ACCESSIBLE (1) 2AIOB(: FIRE EXT. (TYP.) BY TEN. 6.0. NOTE: 7 NOTE: ALL FINISHES SHALL HAVE A MINIMUM MAINTAIN A MINIMUM OF CLASS I FLAME SPREAD RATINC, OR JI 56" AISLES 51!7NEMN HAVE A FIRE RETARDANT TREATMENTFIXTURES. PER A.P.A. REQ. TO ARCHI!\/M THIS RATIN6. 12'-0" LONG METAL SLATNALL BETWEEN STANDARDS T A MALL SERVICE CORRIDOR N.I.C. EXISTIN6 DEM ISINCS ?PARTITION----, VESTIBULE 6ONVOLA SALES MXISTIN(S DEM ISIN(5 PARTITION Y 2246 COPYRIGHT NOTICE; These drawings and specifications are subject to copyright protection as or under sec. 102 of the copyright act NEW DEMISING amended december 1990. The profm PARTITION BY L.L. without limitation, the overall form, a composition of spaces, and elements Under such protection, unauthorized drawings and specifications may resu construction, building seizure, and/or NEUTRAL PIER 12 GYP. 50. DISPLAY Al SOFFIT PLATFORM A/ ABOVE ACOV FINISH ONVOLA TYPICAL SH U Lo Go W= / 41� Go 40 �M C CQ P% I/2' CLEAR at C* IM =AR TEMP. C4 &LAZIN6. U 4 -WAY I�___LMASMLINM 0 UJ J --11 STOREFRONT a) a UM NESTING 516N ATTACHED 0 III I TABLES TO CANOPY W ABOVE. W0 LN it C 1^2 do 0 A5 V A III IIN—A4A6 III I b�—) M mom C IN-- as M 1A C4 IA %A III IIL '---4,9NTr;RL1NE OF r ROLL -UP GRILLE all/ A� dvylp. BD. I 1/2" CLEAR TEMP. -7 _Tff SOFFIT I 6LAZIN6. DISPLAY PLATFORM TYPICALN/ WOOD FINISH STANDARD Al . ....... .. .__ LINE OF FLOOR TRANSITION NEW DEMISING PARTITION BY L.L- SURFACE MOUNTED STANDARDS (TYP.) ADJACENT TENANT AUDIO 26 ELEC. EQUIP. SEE SHT. MI HVY. DUTY HAN&ROV ON HEAVY DUTY NEW SURFACE MTD. STVS. DRINKING SHELVES ABOVE FOUNTAIN (SME TYP. PET) ISTOCKROOM I �4 SHOE Sol, x 48ll RACK CLEAR FLOOR MM SPACE (TYP.)­ (1) 2AI05Co INIRM T EXT. (T'I'P.) BY TEN. dv.C, 4.1 v , 'N 1HALLWAY 1 2 ADJACENT TENANT FIXTURE PLAN (CONT'0) EXISTING DEMISING PARTITION 4 EXIST. MALL NEUTRAL PIER DEM ISI N(S PARTITION SCALE: 1/4" = 1'-0" U1 NMIN DEMISING PARTITION BY L. L. .... . . ...... frn in 10,9 IFi, L 25 A9 1_MANAGERS 28 DESK ON TOILET 4 B JUN 0 vv GRAB BARS. 611 X &011 r II NEW CLEAR FLOOR TOILETI Z DRAWN BY: 41 A2 PROJECT No.: r4 0 LINE OF METAL STUDS AND GYP. NEW -WOOD DEMISING FITTING ROOM SEAT BOARD FITTIN(9 PARTITION LEDGE. FURNISHED ii ROOM PARTITIONS -� BY L,L;7:-� Ir BY n.E.M.C. I NST. BY G.G. SURFACE MOUNTED STANDARDS (TYP.) .... ... ... 5 -0" / GER.1 F.R.3 i FF. -R—. -21 [F.A.11 12 TYPICAL -HOOKS ®i HOOKS Al STANDARD A.F.F. +60" A.F.F. (TYP-) 4-AAY- A41 llk�'[ 14 3 G 6. E SIC7N 6 3/ ABOVE 2 2 I A TY ICAL 5T NP ARP ROUNDERS 4 -WAY 777F PL 1.2 TYPICAL A-? STANDARD MIRROR_ YNY411_14% IV �-MXISTI N6 DEMISING PARTITION E PLAN NOTE: ALL FINISH WOOD SHALL BE KILN -PRIMP, MILL DUALITY FINISH AND ALL WOOD SHALL RECEIVE111 A FIRE RETARDANT COATIN& OR. TREATMENT. NO WOOD OR OTHER COMBUSTABILM MATERIAL SHALL BE USED ABOVE ANY CMILINO. SURFACE MOUNTED STANDARDS (TYP.)- ISALES IZ-O" LONG METAL. SLATNALL BETWEEN STANDARDS--_ ADJACENT TENANT SURFACE MOUNTED STANDARDS (TYP.) LINE OF FLOOR, NVOLA A6 /---GONDOLA TRANSITION--,,,, 45" LONG X 56" HI(SH PULL-OUT H.C. TRANS- ACTION COUNTER- CUSTOM C�SH/ DISPLAY COUNTER. / METAL SLATNALLON BACKSIDE OF LOW I L ADJACENT TENANT PROVIDE DISABLED (Z;HEC,K9TANP 916NA6M AT GASH/WRAP ACCESSIBLE (1) 2AIOB(: FIRE EXT. (TYP.) BY TEN. 6.0. NOTE: 7 NOTE: ALL FINISHES SHALL HAVE A MINIMUM MAINTAIN A MINIMUM OF CLASS I FLAME SPREAD RATINC, OR JI 56" AISLES 51!7NEMN HAVE A FIRE RETARDANT TREATMENTFIXTURES. PER A.P.A. REQ. TO ARCHI!\/M THIS RATIN6. 12'-0" LONG METAL SLATNALL BETWEEN STANDARDS T A MALL SERVICE CORRIDOR N.I.C. EXISTIN6 DEM ISINCS ?PARTITION----, VESTIBULE 6ONVOLA SALES MXISTIN(S DEM ISIN(5 PARTITION Y 2246 COPYRIGHT NOTICE; These drawings and specifications are subject to copyright protection as or under sec. 102 of the copyright act NEW DEMISING amended december 1990. The profm PARTITION BY L.L. without limitation, the overall form, a composition of spaces, and elements Under such protection, unauthorized drawings and specifications may resu construction, building seizure, and/or NEUTRAL PIER 12 GYP. 50. DISPLAY Al SOFFIT PLATFORM A/ ABOVE ACOV FINISH ONVOLA TYPICAL SH U Lo Go W= / 41� Go 40 �M C CQ P% I/2' CLEAR at C* IM =AR TEMP. C4 &LAZIN6. U 4 -WAY I�___LMASMLINM 0 UJ J --11 STOREFRONT a) a UM NESTING 516N ATTACHED 0 III I TABLES TO CANOPY W ABOVE. W0 LN it C 1^2 do 0 A5 V A III IIN—A4A6 III I b�—) M mom C IN-- as M 1A C4 IA %A III IIL '---4,9NTr;RL1NE OF r ROLL -UP GRILLE all/ A� dvylp. BD. I 1/2" CLEAR TEMP. -7 _Tff SOFFIT I 6LAZIN6. DISPLAY PLATFORM TYPICALN/ WOOD FINISH STANDARD Al . ....... .. .__ LINE OF FLOOR TRANSITION NEW DEMISING PARTITION BY L.L- SURFACE MOUNTED STANDARDS (TYP.) ADJACENT TENANT AUDIO 26 ELEC. EQUIP. SEE SHT. MI HVY. DUTY HAN&ROV ON HEAVY DUTY NEW SURFACE MTD. STVS. DRINKING SHELVES ABOVE FOUNTAIN (SME TYP. PET) ISTOCKROOM I �4 SHOE Sol, x 48ll RACK CLEAR FLOOR MM SPACE (TYP.)­ (1) 2AI05Co INIRM T EXT. (T'I'P.) BY TEN. dv.C, 4.1 v , 'N 1HALLWAY 1 2 ADJACENT TENANT FIXTURE PLAN (CONT'0) EXISTING DEMISING PARTITION 4 EXIST. MALL NEUTRAL PIER DEM ISI N(S PARTITION SCALE: 1/4" = 1'-0" U1 NMIN DEMISING PARTITION BY L. L. .... . . ...... frn in 10,9 IFi, L 25 A9 1_MANAGERS 28 DESK ON TOILET 4 copyrighted and "architectural work" 17 u.S.C. As tion includes 'rongemeni an� of the design. use of these t in cessation of monetary liability. Z 5 am LU LL LU LLJ Z W Z Z D &A Z LAV. A/ NEW JUN 0 vv GRAB BARS. 611 X &011 r II NEW CLEAR FLOOR TOILETI SPACE (TYP.) copyrighted and "architectural work" 17 u.S.C. As tion includes 'rongemeni an� of the design. use of these t in cessation of monetary liability. Z 5 am LU LL LU LLJ Z W Z Z D &A Z Z 0 L-1 JUN 0 vv DATE: SHEET: SCALE: DRAWN BY: 41 A2 PROJECT No.: r4 0 O to R0, LJ_ Ln 00 rM P4 nOi < 0, t: of 0 (D Im C Z -j6 0 U Ln 0 F2 & (4 Ln + Vill E R C V cc E JUN 0 vv DATE: SHEET: SCALE: DRAWN BY: AMJ A2 PROJECT No.: 9, � 0 n � Ron ,GN NEW DEMISIN6 1A1%-VNTTI NEW DEM151N6 -A-1-2-LI DOJ I 1 FLOOR FINISH PLAN SCALE: 1/4" = I'—O" NOTE: FT -I TILE 5ORDERIN6 FT -2 SHOULD BE PULL TILES. SET ALL BORDER TILE FIRST. W Z 2, EXIST. L PARTITI MAI SERV CORR N.1.: FLOOR FINISH PLAN CONT'D ADJACENT PARTITION �w�G.1-II�II�IV TION TENANT SCALE: 1/4" = 1'-0 PERIMETER tOOFIN6 AT OOM (MIN. OP :ONTAL $ 4" �L @ WALLS. 2246 CQP-(RIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. � V V L � 4 _ CQ^ 0V0 i■- A� W DoZ No 0 IW O an M VfNVftA ac W Z V ,Z V Z J N N Z K l ;; 1K t^�era 99 a i 4 .9 k ```"`S ; 0 �Q i E c JUM 6 '06 DATE: (0/1/0(0 SHEET: SCALE: DRAWN BY: 1/411=11-01, JDD A2 PROJECT No.: DEM06024 NOTE: THE EXPOSED, DECK AND STRUCTURE SHALL BE DETAILED FOR EXPOSURE: ALL CONDUITS SHALL BE GANGED, PARALLEL AND PERPENDICULAR TO LEASE LINES, ALL PIPES, DUCTS AND FIXTURES . SHALL BE SUPPORTED BY HANGRODS, NOT WIRE. REMOVE ANY UNUSED ITEMS. O REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" NOTE: PLACEMENT OF SPEAKERS 4 AUDIO EQUIPMENT TO BE BY THE 'ROSE CORP' CONDUIT TO BE PROVIDED BY G.G. SPEAKERS MUST NOT BE AUDIBLE FROM MALL AND MUST BE LOCATED A MINIMUM OF 20' INTO SPACE. NOTE: ALL LIGHT TRACK AND DIFFUSERS ARE TO BE MTD. 0 II' 10" A.F.P. I DIMENSIONS ARE TYPICAL UNLESS OTHERWISE NOTED i SEE DETAILS 261 6 30/Adl FOR L16HT FIXTURE MOUNTING. I CEILING PLAN SYMBOL LEGEND KEY SYMBOL DESCRIPTION K i 48)' CEILING MTD TWO TUBE FLUORESCENT STRIP FIXTURE (EXPOSED TUBES). M t= = CUSTOM HANGING LIGHT BAR W/ CLAMP -ON FIXTURES T CEILING PLAN SYMBOL LEGEND KEY SYMBOL DESCRIPTION UNISTRUT MOUNTED ILLUMINATED EXIT SIGN. X2 -7- WALL MOUNTED ILLUMINATED EXIT SIGN. X3 A WALL MOUNTED ILLUMINATED EXIT 816N. Y 460� 2X2 RECESSED FLUORESCENT LIGHT FIXTURE B V NOT USED G O PENDANT MOUNTED INCANDESCENT L16HT FIXTURE D ® CLAMP -ON MOUNTED BIAX FLUORESCENT FIXTURE �I M STORE SECURITY CAMERA DESIGNATED BY NUMBER E y WALL MOUNTED INCANDESCENT LIGHT A/ GUARD G O RECESSED INCANDESCENT DOWN LIGHT Ln ;;==c Lh N H -0 RECESSED INCANDESCENT DOWNLIGHT J 17 TRACK HEAD W/ POWER PACK NOTE: ALL LIGHT TRACK AND DIFFUSERS ARE TO BE MTD. 0 II' 10" A.F.P. I DIMENSIONS ARE TYPICAL UNLESS OTHERWISE NOTED i SEE DETAILS 261 6 30/Adl FOR L16HT FIXTURE MOUNTING. I CEILING PLAN SYMBOL LEGEND KEY SYMBOL DESCRIPTION K i 48)' CEILING MTD TWO TUBE FLUORESCENT STRIP FIXTURE (EXPOSED TUBES). M t= = CUSTOM HANGING LIGHT BAR W/ CLAMP -ON FIXTURES T Q LIGHTING TRACK SECTIONS (LENGTH AS INDICATED ON PLAN). XIS UNISTRUT MOUNTED ILLUMINATED EXIT SIGN. X2 -7- WALL MOUNTED ILLUMINATED EXIT SIGN. X3 WALL MOUNTED ILLUMINATED EXIT 816N. Y 460� SURFACE MOUNTED DUAL HEAD EMERGENCY L16HT UNIT WITH COMPACT ro r- BATTERY PACK, MOUNTING HGT. OF 6" ABV. GROWN MOLDING IN Ln C00 SALES AND 12'-O" A.F.F. IN STOCKROOM AND HALLWAY, BRACE A n LATERALLY AS REQUIRED. �I M STORE SECURITY CAMERA DESIGNATED BY NUMBER NOTE: SEE SHEET E3 FOR LI6HT FIXTURE SCHEDULE d TECHNICAL SPECIFICATIONS FOR L16HT FIXTURES. SER� CORA 2X4 SUS T -BAR C SYSTEM • _---EXIST. MALL NEUTRAL PIER RECESSED CAN L16HTS MOUNTED IN GYP. BD. SOFFIT LIGHT TRACK MOUNTED TO UNDERSIDE OF SOFFIT STORE 516N MTD. TO STOREFRONT CANOPY POWDER COATED STOREFRONT 516N CANOPY, FINISH BOTTOM W/ POLISHED ALUM I NUM DIAMOND PLATE LIGHT TRACK MOUNTED TO UNDERSIDE OF SOFFIT RECESSED CAN LIGHTS MOUNTED IN GYP. BD. SOFFIT i SEXIST. MALL II NEUTRAL PIER NVJA%OCN 1 T -BAR GEILIN6 TENANT SYSTEM REFLECTED_ CEILING PLAN (CONTV SCALE: 1/4" = 1'-0" E AY -IN PVE .---(:2) 2246 COPYRIGHT NOTI�E These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 40 Lo V LGo e-• _ =Go Q^ 0 V W Go LLMd o �: Z 13 Z woCL m a h N Vf %A 0 O at W Z Z Z F a z O to Z O N of ,JUN K '06 DATE: 6/1/06 SHEET: SCALE: 1/411=11-011 DRAWN BY: JDD A3 PROJECT No.: DEM06024 Q tU 'S m y� N Q N a 00 o � ON � a ro r- N Ln C00 A n C O N d E a`000, g o a, .c Ln ;;==c Lh N I to H all 3 M C 10 t ter:! E C C ri't, L ,JUN K '06 DATE: 6/1/06 SHEET: SCALE: 1/411=11-011 DRAWN BY: JDD A3 PROJECT No.: DEM06024 d C L' SUBMIT SIGN MANUFACTURERS SHOP DRAWINGS FOR OR REVIEW .............. STOREFRONT S16NS POWDER COATED EXISTING MALL EXISTIN6 MALL 34 �MF-I PROVIDED BY OTHERS, TO Z CANOPY W/ POLISHED MF -I 34 i BULKHEAD BULkHt=AD--- Aq BE REVIEWED UNDER qg ALUM. DIAMOND PLATE Aq SEPARATE SUBMITTAL. @ UNDERSIDE q5 MF -I 3/4" BLACK ANODIZED . . . . . . ALUM. CHANNEL REVEAL . . . . . ' . 33 �2" X 2" &LASS CLIPS GRILLE SUPPORT 2" X 2" GLASS CLIPS W/ MF -I FINISH TUBES CLAD,38 MF -1 Aq MF_I W/ MF -I FINISH Aq STOREFRONT ELEVATION NOTE: r PROVIDE A SEPARATE S16NA6E SUMITTAL FOR ■ REVIEW AND APPROVAL. EXISTING DEMISING PARTITION-----, 5/5" TYPE "X" GYP. BD. OVER 3 5/8" X 20 6A. METAL STUDS ® 16" O.G. TAPED $ SANDED SMOOTH TO RECEIVE FINISH.-- 11 INISH. -•-_ 11 ~ i 4 ' m A5 -t- �r EXISTING NEUTRAL PIER 3/4" BLACK ANOD. ALUM. CHANNEL REVEAL POWDER COATED METAL 8 3/4" M.D.F. 8 5/6" TYPE "X" 6YP. BD. OVER 3 5/8" X 206A. MTL STUDS # 16" O.G. /2" CLEAR TEMPERED Ab STOREFRONT cSLAZIN6 A/1/4" BUTT JO I NTS 10" V-11 5/4" 10" 8 1/4" t 30'-0" (FIELD VERIFY) 8 1/4" ENLARGED STOREFRONT PLAN it SCALE: 1/2"=1'-O" NEW DEMISING PARTITION BY LANDLORD 5/6" TYPE "X" 6YP. BD. OVER 3 5/6" X 20 6A. METAL STUDS @ 16" O.G. TAPED 8 SANDED SMOOTH TO RECEIVE FINISH. r E NEW NEUTRAL PIER BY LANDLORD 3/4" BLACK ANOD. ALUM CHANNEL REVEAL POWDER COATED METAL B 3/4" M.D.F. B 5/8" TYPE "X" 611rP. BD. OVER 3 5/8" X 206A. MTL STUDS ® 16" O.G. SCALE: 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. Aim C Q P% 0Vo PM di W "� 114 • LCL ca :5 �Zv o O L Z FM =00 W 04M O EO m4) an C Vf N %A Vf Q c� � III 0 ar W W Z 0 Z W Z J SHEET: 6/I /06 SCALE: d AMJ 0 PROJECT No.: Di:M06024 BLACK ANODIZED POWDER COATED METAL tA C' PANELS. d O ALUM. CHANNEL REVEAL MF -I y N C1 N t` 8 00 rn � o 00 ea U- to N cLn 00 a� M o _N t � u o d atZ,ro c 4y In ° °� `•= .— r LA u + s,a� _ O ' POWDER COATED METAL PANELS. MF -I 1/2" X 1/2" REVEAL W/ FINISH T'I'P. MF -I �F, law CTO r�!�l C fir,4Y; LANDLORDS _ _ f ;' • = t v �e sEXISTING J .Tfu BLACK NEUTRAL PIER. PATCH, # / ALUMINUM GLAZIN6HEAD REPAIR A5 NECESSARY. I - , 1/2" X 1/2" REVEAL W/ 1-3/4" BLACK ANODIZED I l j ' ALUMINUM 6LAZIN6 HEAD j / • . / / ` MF -I „ -4 MF -I 1/2" CLEAR TEMPERED . . / f ,r / NEUTRAL PIER - N BY LANDLORD. STOREFRONT 6LAZIN6 Al ;1 / 1/4" BUTT JOINTS i :.: :: ROLL -DOWN • . I � I/2" CLEAR TEMPERED 3/4" BLACK ANODIZEDr' ALUM. CHANNEL REVIrAL • I_ GRILLE 1 D-1 i ' i// i STOREFRONT 6LAZ1 6 W/ 1/4 BUTT JOINTSN 2" HIGH POWDER COATED ANGLE TRIM. 3/4" BLACK ANODIZED ALUM CHANNEL REVEAL 10" HIGH POLISHED IGH POWDER DIAMOND PLATE ' COATED ANGLE TRIM. t r. I / .-- ., v. 1. t 1 11 , rI. G f., rJ p ' •x,.51 .,t., fr y ::'1 .. ..i .:1 1• <.' C' _ 1 1 "r _ ... u 10 HIGH POLISHED '. l�. ! ri i•; •', r7. C7 ' ,..// t -t ,a,•, r c 7 n � a ,,Y , � r !-% /✓L` ,.i2 .y / .J .%�.! r Y U t✓ •,., t .-.. = ,• ..• ,,. . ,..., .J,.., r, •./..f t r <.✓ :^ t I tT.a-= leo•m,tis \ a ^ b \ r .�/ v�?:.��a,u?.r`.•s\ Y \��Y � \� ti 5 o r< s/ riy ;a�,i�:a�ar,� C.y e• C 1 i rrraN,r:i>Zr✓?�`r�. c.�t�uA�C ��� 4 tia���ra�•y� DIAMOND PLATE �v rrn,- y Ul�,.,e-a.� Ott. 33 �2" X 2" &LASS CLIPS GRILLE SUPPORT 2" X 2" GLASS CLIPS W/ MF -I FINISH TUBES CLAD,38 MF -1 Aq MF_I W/ MF -I FINISH Aq STOREFRONT ELEVATION NOTE: r PROVIDE A SEPARATE S16NA6E SUMITTAL FOR ■ REVIEW AND APPROVAL. EXISTING DEMISING PARTITION-----, 5/5" TYPE "X" GYP. BD. OVER 3 5/8" X 20 6A. METAL STUDS ® 16" O.G. TAPED $ SANDED SMOOTH TO RECEIVE FINISH.-- 11 INISH. -•-_ 11 ~ i 4 ' m A5 -t- �r EXISTING NEUTRAL PIER 3/4" BLACK ANOD. ALUM. CHANNEL REVEAL POWDER COATED METAL 8 3/4" M.D.F. 8 5/6" TYPE "X" 6YP. BD. OVER 3 5/8" X 206A. MTL STUDS # 16" O.G. /2" CLEAR TEMPERED Ab STOREFRONT cSLAZIN6 A/1/4" BUTT JO I NTS 10" V-11 5/4" 10" 8 1/4" t 30'-0" (FIELD VERIFY) 8 1/4" ENLARGED STOREFRONT PLAN it SCALE: 1/2"=1'-O" NEW DEMISING PARTITION BY LANDLORD 5/6" TYPE "X" 6YP. BD. OVER 3 5/6" X 20 6A. METAL STUDS @ 16" O.G. TAPED 8 SANDED SMOOTH TO RECEIVE FINISH. r E NEW NEUTRAL PIER BY LANDLORD 3/4" BLACK ANOD. ALUM CHANNEL REVEAL POWDER COATED METAL B 3/4" M.D.F. B 5/8" TYPE "X" 611rP. BD. OVER 3 5/8" X 206A. MTL STUDS ® 16" O.G. SCALE: 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. Aim C Q P% 0Vo PM di W "� 114 • LCL ca :5 �Zv o O L Z FM =00 W 04M O EO m4) an C Vf N %A Vf Q c� � III 0 ar W W Z 0 Z W Z J JUN 5 Ub DATE: SHEET: 6/I /06 SCALE: d AMJ 0 PROJECT No.: Di:M06024 tA C' d O y N C1 N t` 8 00 rn � o 00 ea U- to N cLn 00 a� M o _N t � u o d atZ,ro c 4y In ° °� `•= .— r LA u + s,a� ' as �F, law CTO r�!�l C fir,4Y; ``E r JUN 5 Ub DATE: SHEET: 6/I /06 SCALE: DRAWN BY: AMJ A4 PROJECT No.: Di:M06024 ■ TENANT MUST SEAL OFF THE CEILING SPACE OF THEIR ROOM FROM THE n u gun Deere nC T = u&l 1 TA Tua OMC flF/M[ ALUMINUM 6LAZIN6 AIR GAP BETWEEN 6LAZIN6 PANELS STOREFRONT GLAZING DETAIL i� DETAIL @ ROLL -UP GRILLE SUPPORT TUBE DETAIL @ NEUTRAL PIER DETAIL @ NEUTRAL PIER 6 SCALE: 1-1/2" = I' -O" M 1 SCALE: 1-1/2" T7-(::>- -O" SCALE: 1-1/2" = 1'-0" 1 3 SrALE: 1-1/n" = 77" STOREFRONT SECTION 4" X 4" STEEL TUBE W/ M12-1 FINISH. -- BLACK ALUM. ROLL -UP GRILLE 0011:)r- CENTER UIDE CENTER LINE OF ROLL -UP GRILLE 1/2" CLEAR TEMPERED 6LASS SET IN ALUMINUM 6LAZIN6 CHANNELS, TOP AND BOTTOM:--- 50LIP OAK BULLNOSE TRIM IN/ STAINED FINISH. EXISTIN6 MALL BULKHEAD TEN. 6.6. SHALL PROVIDE ONE LAYER Oi= 5/8" TYPE "X" 6YP. BD. @ BACKSIDE FULL HEIGHT TO DECK ABOVE EXISTIN6 DEMIST PARTITION EXISTIN6 STRUCTURAL STEEL TUBE COLUMN --- EXIST. EXIST. NEUTRAL PIER - 3/4" BLACK ANODIZED ALUM. CHANNEL REVEAL 2X2,2 -HOUR RATED SUSPENDED T -BAR CEILIN6 SYSTEM STOREFRONT SECTION I" SET BACK FROM 5/8" TYPE "X" 6YP. BD. TO DISPLAY AREA 5/6" TYPE "X" GYP. BD. DYER 3-5/6" X 20 6A. METAL STUDS 16" D.G. TAPED d SANDED SMOOTH TO RECEIVE FINISH-- " CLEAR TEMPERED &LASS 2" X 1-1/2" METAL ANGLE POWDER COATED MF -I POWDER COATED METAL d 5/4" M.D.F. a 5/8" TYPE "X" 6YP. BD. OVER 3-5/8" X 2O6A. MTL STUDS ® 16" O.G. EXISTIN6 MALL BULKHEAD TEN. 64, SHALL PROVIDE ONE LAYER OF 5/5" TYPE "X" 6YP. BD, a BACKSIDE FULL HEIGHT TO DECK ABOVE NEW DEMISING PARTITION BY L.L. EXISTIN6 STRUCTURAL STEEL TUBE COLUMN NEW NEUTRAL PIER BY L.L. 3/4" BLACK ANODIZED ALUM. CHANNEL REVEAL 2246 QOPYRIGHT MICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 40 1W Sm =V UGo�- c C41 cc Q� ou© � � W 1i111J • Lill. N G O p Z� O t/1 OM C Z %A NMg %A IIA O W W z z W Z J D H Z O u n "t' DATE: SCALE: I .=I _0 DRAWN BY: JDD PROJECT No.: DEM06024 !UN s 16 SHEET: A5 NOTE: PROVIDE CLEAR SILICONE SEALANT AROUND ALL ITEMS IN 0 PITTING ROOMS. PROVIDE METAL SACKINO IN WALLS ■ AS REQUIRED FOR ATTACHMENT OF WALL STANDARDS 00 NOT USE TOSSLE BOLTS I STOCK ROOM FINISHES: ALL GYP 51P HALL SUPtPlAC,195 ARE TO 50 PRIMED AND THEN PAINTED (P-4) SEMI &LOSS, AND RELIEVE A 6" HIGH RUBBER■ BASE (5-2) I 6" 0400D GROWN MOULVIN6 RECESSED HALL EXIT SIGN It" ABOVE TOP OF DOOR FRAME CENTERED BETWEEN STANDARDS semi . — — —k - — 10" HIGH BRUSHED STAINLESS STEEL KICK PLATE REMOTE 5EN50R @ 46" A.P.F.C5-1 INTERIOR ELEVATION. 9" HOOP GROWN MOULDING I I I 6" HOOD GROWN UNISTRUT MOUNTED ILLUMINATED EXIT 6" HOOD GROWN MOULD IN6 CUSTOM HALL H16H r STANDARDS 0:24" O.G. ^001:> BASE N/ STEEL ANGLES. SEE Z WF_IHOOD DISPLAY TYPICAL DETAIL, DISPLAY PLATFORM PLATFORM SCALE: 1/4' I' -O" INTERIOR ELEVATION SCALE: I/4"= I' -O" EMER6ENCY LIGHT FIXTURE. (50 SHALL APPLY 515" EMEROENCY LIGHT NC -S SEE REFLECTED aL6. PLAN. ------- TYPE "X" GYP. BV. ABOVE FIXTURE. SEE V400V GROWN SLATNALL, (TYP.) REFLECTED C1.6. PLAN. MOULDING CUSTOM WALL STANDARDS 024" O.G. A/ STEEL AN(SLES, 7= RUM— 6/1/06 SEE TYPICAL DETAIL. SCALE: Ca 16m 0 T, Sim TM r% 0VO . . . ........ LU j 41 C N 0 UM __ 0 3: z 1111, 8 00 TFMM TITM 0 O W m %I= c M + Li- V1 (4 &A %A COILED OVERHEAD 0 N .N't E "0 < co 0 IM 8 0 a) ON r GRILLE A ,c"" 2. 1/2" CLEAR TEMPERED un U Un I-- 14 STOREFRONT GLAZING as /V ev,-`nij A/ 1/4" BUTT JOINTS Y D-1 1/2" CLEAR TEMPERED STOREFRONT CPLAZIN& C V A/ 114" BUTT JOINTS /4 4" 90 GRILLE y SUPPORT COLUMN. FINISH ALL - 0. T CUSTOM HALL H16H r STANDARDS 0:24" O.G. ^001:> BASE N/ STEEL ANGLES. SEE Z WF_IHOOD DISPLAY TYPICAL DETAIL, DISPLAY PLATFORM PLATFORM SCALE: 1/4' I' -O" INTERIOR ELEVATION SCALE: I/4"= I' -O" EMER6ENCY LIGHT FIXTURE. (50 SHALL APPLY 515" EMEROENCY LIGHT NC -S SEE REFLECTED aL6. PLAN. ------- TYPE "X" GYP. BV. ABOVE FIXTURE. SEE V400V GROWN SLATNALL, (TYP.) REFLECTED C1.6. PLAN. MOULDING PITTING ROOM \--CUSTOM HALL STANDARDS H16H \�,—CUSTOM HALL STANDARDS \"-6" HIGH A7 B-1 MIRROR, SEE *24" O.C. N1 STEEL ANGLES. B-IN0017 BASE 2 B-1&24" O.C. A/ STEEL AN&LES. WOOD BASE DETAIL 5/A7. SEE TYPICAL DETAIL. SEE TYPICAL DETAIL. INTERIOR ELEVATION, 6" HOOP GROWN MOULD INO EHERCvENCY LIGHT FIXTURE. SEE REFLECTED r -L&. PLAN. -----_",MOULD I N6 6" WOOD GROWN SHALL APPLY 5/5" TYPE "X" GYP. 5V. ABOVE SLAT^ALL. (TYP.) SCALE! 114"=I' -O" EMER&ENCY LldHT FIXTURE. SEE REFLECTED CL&. PLAN. CUSTOM WALL STANDARDS 024" O.G. A/ STEEL AN(SLES, Z RUM— 6/1/06 SEE TYPICAL DETAIL. SCALE: Ca 16m 0 PROJECT No.: Sim TM r% 0VO LU j 41 C N 0 UM __ 0 3: z 1111, 8 00 0 O W m %I= c M + Li- V1 (4 &A %A 0 N .N't E < co 0 IM 8 0 a) ON r 0 00 Ln 45 V ,c"" 2. 0 + un U Un I-- 14 75,11'. as ev,-`nij C V FITTINO ROOM MIRROR, SEE A VETAIL =2� OAK VENEER FiTTiN(5 Rm. 5mNCH K PITTING ROOM \--CUSTOM HALL STANDARDS H16H \�,—CUSTOM HALL STANDARDS \"-6" HIGH A7 B-1 MIRROR, SEE *24" O.C. N1 STEEL ANGLES. B-IN0017 BASE 2 B-1&24" O.C. A/ STEEL AN&LES. WOOD BASE DETAIL 5/A7. SEE TYPICAL DETAIL. SEE TYPICAL DETAIL. INTERIOR ELEVATION, 6" HOOP GROWN MOULD INO EHERCvENCY LIGHT FIXTURE. SEE REFLECTED r -L&. PLAN. -----_",MOULD I N6 6" WOOD GROWN SHALL APPLY 5/5" TYPE "X" GYP. 5V. ABOVE SLAT^ALL. (TYP.) SCALE! 114"=I' -O" EMER&ENCY LldHT FIXTURE. SEE REFLECTED CL&. PLAN. \"--CUSTOM HALL STANDARDS 6" HIGH/ o=4" O.C. A/ STEEL AN6LES. WOOD BASE---"" SEE TYPICAL DETAIL. CUSTOM WALL STANDARDS 024" O.G. A/ STEEL AN(SLES, Z --6.1 HIGH WOOD BASE 6/1/06 SEE TYPICAL DETAIL. SCALE: Ca 16m 0 PROJECT No.: Sim TM r% 0VO LU j 41 C N 0 UM __ 0 3: z 1111, 8 00 0 O W m %I= c M + Li- V1 (4 &A %A 0 N .N't E < co 0 IM 8 0 a) ON r 0 00 Ln 45 V ,c"" 2. 0 + un U Un I-- 14 75,11'. as ev,-`nij C V =2� \"--CUSTOM HALL STANDARDS 6" HIGH/ o=4" O.C. A/ STEEL AN6LES. WOOD BASE---"" SEE TYPICAL DETAIL. a \---,—NALL MIRROR., SEE DETAIL 2/Ai. 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. CUSTOM WALL STANDARDS 024" O.G. A/ STEEL AN(SLES, Z --6.1 HIGH WOOD BASE 6/1/06 SEE TYPICAL DETAIL. SCALE: a \---,—NALL MIRROR., SEE DETAIL 2/Ai. 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. JON 5 '06 DATE: Z 6/1/06 SCALE: Ca 16m 0 PROJECT No.: Sim TM r% 0VO LU j 41 C N 0 UM __ 0 3: z 1111, 8 00 0 O W m %I= c M + Li- V1 (4 &A %A JON 5 '06 DATE: Z 6/1/06 SCALE: DRAWN BY. 0 PROJECT No.: VEM06024 0- 8 00 ON 00 00 V, M + Li- L"n C 00 0 N .N't E < co 0 IM 8 0 a) ON r 0 00 Ln 45 V ,c"" 2. 0 + un U Un I-- 14 75,11'. as ev,-`nij C V JON 5 '06 DATE: SHEET: 6/1/06 SCALE: DRAWN BY. A6mO PROJECT No.: VEM06024 NOTE: PROVIDE CLEAR SILICONE SEALANT AROUND ALL ITEMS IN ■ i"ITTIN6 ROOMS. NOTE; PROVIDE METAL BACKING IN WALLS ■ A5 REQUIRED FOR ATTACHMENT OF WALL STANDARDS DO NOT USE T06OLE BOLTS I uu •i,,...w,. U,.4... W,-.5 T7.1-2... I T,S STOCK ROOM FIMSHES: 'ALL GYP BD WALL SURFACES ARE TO BE PRIMED AND THEN PAINTED (P-4) SEMI ■ 6LOS5, AND RELIEVE A 6" HIGH RUBBER BASE (5-5) 4'-0" HIGH WHITE PRP WAINSCOT, TYP. ALL WALLS - NEW 42" GRAB m - d) P-4 'SHOPL I PTI N6 15 A GRIME' 4'-0" H16H WHITE 516N. APPLY TO MIRROR W/ . FOAM TAPE 4 CLEAR ' w SILICONE (TYP EACH P.R.) under sec. 102 of the amended december copyright act, 17 u,S,C. As 1990. The protection includes, without limitation, composition the of spaces, overall form, arrangement and and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. vi WALL MIRROR, 5EE ! " DETAIL S/A'1. O 0 all a, All M V9 N O. n 0 all o Ch rn c o Go CN 0 0 INTERIOR ELEVATION TOILET ROOMS SHALL CONFORM TO ALL AGGE55ABILITY REOUIREMENT5 BUT NOT LIMITED TO THE FOLLOWING: A. WATER CLOSET SEAT HEIGHT - 11" TO iq" A,F,F B. CENTERLINE OF WATER CLOSET - IS" FROM SIDEWALL. G. 6RAB BAR BEHIND WATER CLOSET - 36" LONG - 33-36" A.F.F. D. 6RAB BAR DIAMETER - 11/2" E. 6RA5 BAR AT SIDE OF WATER CLOSET - 42" LONG, 33" TO 36" A.P.F. P. SPACE BETWEEN 6RAB BAR AND WALL - 1-1/2" 6. TOILET PAPER DISPENSER - 36" MAX. FROM REAR WALL, I -R" MIN, A.F.F. H. KNEE CLEARANCE AT LAVATORY - APRON 2q" MIN. HT., 5" MIN. DEPTH. I. LAVATORY DEPYH - 17" MIN, J. LAVATORY DRAIN AND HOT WATER PIPES - INSULATED WHEN EXPOSED. K. LAVATORY RIM SURFACE - MAX. 34" A.P.F. L. MIRROR BOTTOM ED6E - 40" A.F=.P. MAX. M. INTERNATIONAL SYMBOL OF ACGESSASILITY SHALL BE MOUNTED ON THE EXTERIOR OF THE TOILET ROOM WALL. N. DOOR HARDWARE SHALL BE LEVER TYPE. P. TOILET ROOM DOOR HANDICAP 516N MUST BE IN BRAILLE. Amo 3" WOOD GROWN MOULDING STAINED O O, ir O INTERIOR ELEVATION P-4 4'-O" HIGH WHITE PRP WAIN5COT, TYP. ALL WALLS 0 B -I NOTE: TOILET PAPER D15P>rNSERS SHALL a NOT BE A TYPE THAT CONTROL DELIVERY, OR THAT DO NOT ALLOW CONTINUOUS PAPER PLOW. { NOTE: SET TOE OF BASE 5-2 IN CONTINUOUS SEALANT OAK VENEER PITTING RM. BENCH 4'-0" H16H WHITE PRP WAINSCOT, � TYP, ALL WALLS Q O under sec. 102 of the amended december copyright act, 17 u,S,C. As 1990. The protection includes, without limitation, composition the of spaces, overall form, arrangement and and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. vi NOTE: TOILET PAPER D15P>rNSERS SHALL a NOT BE A TYPE THAT CONTROL DELIVERY, OR THAT DO NOT ALLOW CONTINUOUS PAPER PLOW. { NOTE: SET TOE OF BASE 5-2 IN CONTINUOUS SEALANT OAK VENEER PITTING RM. BENCH �9 NEW (2) 36" LONG X 12" DEEP WHITE MELAMINE SHELVING ON H.D. WALL MTD. 5TD5-1- 6" WOOD GROWN MOULDING -a 4'-O" HIGH WHITE PRP WAINSCOT, _ TYP. ALL WALLS 4 N _ � J m in 6RA5 m n BARS NEW LAV. SEE SHT. TOILET SCALE: I/4"= I' -O" B- I 0 =W31B 3" WOOD GROWN MOULDING STAINED OAK VENEER FITTIN6 RM, BENCH 6" WOOD GROWN MOULD I N6 31 CAa 3" WOOD GROW '? MOULDING FD WALL MIRROR, SEE DETAIL 2/A'7. n .�:• INTERIOR ELEVATION B -I 0 INTERIOR ELEVATION 0 BLACK FITTING ROOM DOORS W/ CRACKED (LASS BY FIXTURE GONTRATGOR SCALE: 1/4" = I' -O" 3" WOOD GROWN MOULDIN6 STAINED OAK VENEER PITTING RM. BENCH SCALE: 1/4" = 1'-0" 2246 COPYRIGHT C These subject � and copyright O under sec. 102 of the amended december �9 NEW (2) 36" LONG X 12" DEEP WHITE MELAMINE SHELVING ON H.D. WALL MTD. 5TD5-1- 6" WOOD GROWN MOULDING -a 4'-O" HIGH WHITE PRP WAINSCOT, _ TYP. ALL WALLS 4 N _ � J m in 6RA5 m n BARS NEW LAV. SEE SHT. TOILET SCALE: I/4"= I' -O" B- I 0 =W31B 3" WOOD GROWN MOULDING STAINED OAK VENEER FITTIN6 RM, BENCH 6" WOOD GROWN MOULD I N6 31 CAa 3" WOOD GROW '? MOULDING FD WALL MIRROR, SEE DETAIL 2/A'7. n .�:• INTERIOR ELEVATION B -I 0 INTERIOR ELEVATION 0 BLACK FITTING ROOM DOORS W/ CRACKED (LASS BY FIXTURE GONTRATGOR SCALE: 1/4" = I' -O" 3" WOOD GROWN MOULDIN6 STAINED OAK VENEER PITTING RM. BENCH SCALE: 1/4" = 1'-0" 2246 COPYRIGHT NOTICE: These subject drawings to and copyright specifications are copyrighted and protection as an "architectural work" under sec. 102 of the amended december copyright act, 17 u,S,C. As 1990. The protection includes, without limitation, composition the of spaces, overall form, arrangement and and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. ec O 0 all a, All M V9 N O. n 0 all o Ch rn c o Go CN ra Q N Ou � allW ..1 00 d W o z� , O ~ 0 O .= O V m %I= C V� Go 0 CL to Z 1A C4 Vf 0 V a JUH 6 "Q6 DATE: 6/I /06 SHEET: SCALE: DRAWN BY: JI7D � PROJECT No.: DEM06024 O 0 ec O 0 a, All M V9 N O. n 0 o Ch rn c o ra N Ll1 00 � G O N" E aM o d O1 .c Ln u ;` t3P rtri�t: ;a Ln + r- :;n F— :rei lrr; lit?P#� tPl BJC�i?',iryp ;r+' I' d US"YS+!:Qt d M 1AW V t a JUH 6 "Q6 DATE: 6/I /06 SHEET: SCALE: DRAWN BY: JI7D � PROJECT No.: DEM06024 NOT USED (24" ® H.G. PITTING ROOM) .).FITTING ROOM 2!1 20go. 3-5/8" METAL TRACK 5AGKIN6 AT EACH WALL STANDARD LOG. 5/5" TYPE "X" GYP. BD. WALL SURFACE. SINGLE SLOT HEAVY DUTY STANDARD W/ I" SLOTS AT 2" O.G. USE FLATHEAD SELF TAPPING 5GREW5. ATTACH AT PROVIDED HOLES. X 1-1/2" "L"(T`I'P. BOTH SI DES) METAL STUDS PER SHEET Al 2 x 6 5AGKIN6 CLEAR SILICONE BEAD WHERE PLYWOOD MEETS WALL 4 ® UNDERSIDE OF BENCH WHERE WOOD FRAMING MEETS PLYWOOD 3/4" OAK VENEER All STAINED EDGE ® FRONT ILD OAK TRIM STAINED 2 X 4 FRAMIN6 ® FRONT, BACK, 8 SIDES. FASTEN TO WALL W/ LA6 5GREW5, 6YP. BD. WALL VERIFY GOND I TI ON WALL STANDARD - SALES SCALE: �Id SCALE: 1-1/2" = 1 SECTION @ GRAB BAR E 'X' 61YIP. BD. EEL 5GREWS IN EACH OVIDED IN GRAB BAR �. GRAB BARS PER .Gt'D EON �R TO BE ANCHORED i SRT A 250 LB. POINT ..311 ?B. BLOCKING IN WALL I/4" THICK CLEAR MIRROR W/ FINISHED EDGE NOTES: CLEAR 51LICONE @ PERIMETER. { ». — METAL J -MOLD SCREWED TO WALL AT BOTTOM COLUMN MIRROR DETAIL NOT USED N.T.S. SCALE: 1" = 1'-0" 0 1/4" THICK CLEAR MIRROR W/ FINISHED EDGE NOTES: CLEAR SILICONE ® PERIMETER. METAL J -MOLD SCREWED TO WALL AT BOTTOM WALL MOUNTED MIRROR DETAIL 3" HIGH WOOD MOULDING STAINED TOP OF WALL CONT. 6"x 18 6A. TOP TRACK 5/8" TYPE "X" 6YP. BD. OVER 6" x IS 6A. METAL STUDS ®I b" O.G. TAPE, 8 SAND SMOOTH TO RECEIVE FINISH. CONT. 18 6A. BOTTOM TRACK w/ 2" LONG TAPGONS ® 6" O.G. STA66ERED. ;t SECURE TRACK TO GONG. W/ PANEL ADHESIVE SECTION @ INTERIOR FITTING RM. WALL ■ DEM151N6 WALL, OR AD.JAGENT WALL. SEE FLOOR PLAN SCALE: 1-1/2" = P -O" S/8" TYPE 'X' 6YP. BD. ON METAL STUDS, FINISH PER PLAN. 3/4" FIRE TREATED PLYWOOD SCREW THRU TO STUDS W/ 2-1/2" LON6 SELF TAPPING COUNTERSUNK SCREWS AT 6" O.G. AT BOARD EDGES, S 12" O.C. FOR THE FIELD X 1-1/2" X 20430, METAL.'L' D -- " AT EGE OF PLATfFORM. SCREW (/ SCREW THRU TOP INT PLYWOOV I I I y � �3-5/8" X ISga. METAL STUD PARTITION. SEE FLOOR PLAN X ISga. METAL STUD JOISTS. ®16" O.G. -------- 6" X ISga. METAL STUD PLUMBING WALL. SEE FLOOR PLAN TOILET ROOM PLATFORM DETAIL 'SHOPLIFTING 15 A GRIME' SIGN. APPLY TO MIRROR W/ FOAM TAPE 8 CLEAR SILICONE (TYP EACH F.R.) 1/4" THICK CLEAR MIRROR W/ FINI5H -0 EDGE NOTES: CLEAR SILICONE @ PERIMETER, METAL J -MOLD SCREWED TO WALL AT BOTTOM FITTING ROOM MIRROR DETAIL NOT USED • 2246 COPYRIGHT NOT_IM- These drawings subject to and specifications are copyrighted and copyright protection as an "architectural work" under sec. 102 of the amended december copyright act, 17 u.S.C. As 1990. The protection includes, without limitation, the composition of spaces, I Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. h I � Go 40 a 0 m to N O. N o ^ V 0 00 0% 1 VARIES - SEE ELEVS. E 'X' 61YIP. BD. EEL 5GREWS IN EACH OVIDED IN GRAB BAR �. GRAB BARS PER .Gt'D EON �R TO BE ANCHORED i SRT A 250 LB. POINT ..311 ?B. BLOCKING IN WALL I/4" THICK CLEAR MIRROR W/ FINISHED EDGE NOTES: CLEAR 51LICONE @ PERIMETER. { ». — METAL J -MOLD SCREWED TO WALL AT BOTTOM COLUMN MIRROR DETAIL NOT USED N.T.S. SCALE: 1" = 1'-0" 0 1/4" THICK CLEAR MIRROR W/ FINISHED EDGE NOTES: CLEAR SILICONE ® PERIMETER. METAL J -MOLD SCREWED TO WALL AT BOTTOM WALL MOUNTED MIRROR DETAIL 3" HIGH WOOD MOULDING STAINED TOP OF WALL CONT. 6"x 18 6A. TOP TRACK 5/8" TYPE "X" 6YP. BD. OVER 6" x IS 6A. METAL STUDS ®I b" O.G. TAPE, 8 SAND SMOOTH TO RECEIVE FINISH. CONT. 18 6A. BOTTOM TRACK w/ 2" LONG TAPGONS ® 6" O.G. STA66ERED. ;t SECURE TRACK TO GONG. W/ PANEL ADHESIVE SECTION @ INTERIOR FITTING RM. WALL ■ DEM151N6 WALL, OR AD.JAGENT WALL. SEE FLOOR PLAN SCALE: 1-1/2" = P -O" S/8" TYPE 'X' 6YP. BD. ON METAL STUDS, FINISH PER PLAN. 3/4" FIRE TREATED PLYWOOD SCREW THRU TO STUDS W/ 2-1/2" LON6 SELF TAPPING COUNTERSUNK SCREWS AT 6" O.G. AT BOARD EDGES, S 12" O.C. FOR THE FIELD X 1-1/2" X 20430, METAL.'L' D -- " AT EGE OF PLATfFORM. SCREW (/ SCREW THRU TOP INT PLYWOOV I I I y � �3-5/8" X ISga. METAL STUD PARTITION. SEE FLOOR PLAN X ISga. METAL STUD JOISTS. ®16" O.G. -------- 6" X ISga. METAL STUD PLUMBING WALL. SEE FLOOR PLAN TOILET ROOM PLATFORM DETAIL 'SHOPLIFTING 15 A GRIME' SIGN. APPLY TO MIRROR W/ FOAM TAPE 8 CLEAR SILICONE (TYP EACH F.R.) 1/4" THICK CLEAR MIRROR W/ FINI5H -0 EDGE NOTES: CLEAR SILICONE @ PERIMETER, METAL J -MOLD SCREWED TO WALL AT BOTTOM FITTING ROOM MIRROR DETAIL NOT USED • 2246 COPYRIGHT NOT_IM- These drawings subject to and specifications are copyrighted and copyright protection as an "architectural work" under sec. 102 of the amended december copyright act, 17 u.S.C. As 1990. The protection includes, without limitation, the composition of spaces, overall form, arrangement and and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. h 0 Go 40 a 0 m to N O. N o ^ V 0 00 0% rn Go C r a c 3 0 � M CLn 00 M O ouW C O N "t E J N = • O L,I O Z 4y Z00 Ln 0 tA in E ZIP', m c ..1 0 O IM to a VfNtotA ec W W Z Z w Z F W 0 0 H Z 0 N � Z V 0 a 0 m to N O. N o ^ 0 00 0% rn a c _0+ UN W CLn 00 M O C O N "t E o m an .c Z 4y Ln tA ZIP', lam1 s 13 J - N to ,.�. C p H G JUN is DATE: SHEET: SCALE: DRAWN BY: MJ PROJECT No.: DEM06024 C .1 R -40-B > 5 MAKE PLUSH. ___641. TO PROVIDE SONDIN6 AGENT TO EXISTING SLAB -� V.C.T. TO CONCRETE TRANSITION �V J SCALE: N.T.S. 'HILTI' DN OR DS SHOT PIN I" EMBEDMENT INTO SLAB AT 24" O.G. (I.G.5.0. i 5/8" TYPE "X" 6YP. BD, (TYP. BOTH SIDES). 3 5/5" X 209o. METAL STUD FRAMING (ICSO #ER 46143 P) CONT. 20 6A. BOTTOM TRACK (ICBG #ER 4943 P) i FLOORING 6 BASE MATERIAL (SEE PLANS) EXISTIN6 CONCRETE SLAB TYP. BOTTOM OF PARTITION DETAIL LV % SCALE: 3" = 1'-0" EXISTIN6 METAL PAN DECK EXISTIN6 STEEL ROOF BEAD UNISTRUT BEAM CLAMP 10218>5 STEEL ANGLE 3" X 3" X 1/4" AITH 5/8" DIA. BOLTS, 6.G. TO COORDINATE WITH INSTALLER OF GRILLE DOOR.----- --_------- - — — — — — — --- ---- i UNISTRUT PI000 EACH SIDE OF COLUMN 4" SQUARE STEEL GRILLE SUPPORT TUBE FLASI MIN. C A SMi DOOR IN CLOSED POSITION -MARBLE TILE PER PLAN EXISTING CONCRETE FLOOR SLAB 1/5" ALUM TERRAZZO TRANSITION STRIP. SIZE AS REQUIRED. .MARBLE TILE TO VCT FLOORING Iv / '� NOT USED 41' Cb STL. TUBE SUPPORT PAIR OF GLASS DOORS STEEL SADDLE 2 51 DES. 24 GRILLE SUPP. TUBE CONN. DETAIL (TOP)- 23 SCALE: 1 1/2 11-0.1 L SCALE: N.T.S. TYP. 6ROUT JOINT WIDTH MARBLE TILE I I —MARBLE TILE Q GONG. FLOOR SLAB MAKE 6.C. TO PROVIDE BONDING ALL TRANSITIONS FLUSH. AGENT TO EXISTIN6 SLAB. MARBLE TILE TO MARBLE TILE SCALE, (18 BENT STEEL SADDLE A/ Al n' KAIKSOLT 1/2"0 X 2 1/4" =)MENT INTO CONCRETE 3O #2388) SELF TAPPING TEK SGREA SIDES _- .3TIN6 GONG. FLOOR. STEEL TUBE ANCHOR @ BASE DETAIL SCALE: 3" _ 13 SCALE: N.T.S. 3 5/5" X 20 (SAU6E DIA610NAL BRAGIN6. (10150 #ER 4843 P) 45" O.G. @) 45 ALTERNATE SIDES. SUSP. CLC. SYSTEM SEE REFLECTED CEILING PLAN, METAL STUDS (SEE SHT. AI) 5/8" TYPE "X" 6YP. BD. (TYP. BOTH SIDES). TOP OF INT. WALL BRACING DETAIL. VERIFY THAT THE SHOWN METHOD OF ATTACHMENT IS ACCEPTABLE WITH THE ON-SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. "" -TING METAL PAN DECK. CONT. 20 6A. SLOTTED DEEP LEG TRACK ATTR TO METAL STRAPS. — #10 SELF TAPPING TEK SCREAS @ 16" O.G. SCALE: 3" = 1'-0 5RAGIN6 DETAIL FOR FLOOR SUPPORTED FRAMING ONLY I UNISTRUT PI000 CLAMPED TO TOP CHORD OF JOIST A/ UNISTRUT BEAM CLAMP #P1386. USE UNISTRUT P1003, A/ AIDE BASE FLANGE, AT CONDITIONS AHERE SOFFIT GROSSES TRUSSES. - --1/2" MIN. FOR DEFLECTION. -----(2) #8 TEK SGREAS AT EA. CONNECTION. CONTINUOUS 22 6A. EXISTIN6 JOIST. 3 5/8" X 20 6A. METAL STUDS ® 16" O.G. 22 ATTACHMENT TO STRUCTURE ABOVE TENANT NEW TENANT TILE PLOOKIN6 PROVIDE PLUSH TRANSITION TO EXISTING MALL TILE 0 MALL 1/8" ALUMINUM TRANSITION STRI P EXIST. MALL TILE FLOORING ( VERIPY THICKNESS Q Q EXISS TING CONCRETE Q Q r TENANT TILE TO MALL FLOORING SCALE: N.T.S. DOOR- REFER TO DOOR SCHEDULE (SHEET AI) -HOLLOW METAL DOOR PRAME BY O.C. (RATED WHERE REQUIRED) •(I/4") F.R.T. SHIM (AS REQUIRED) -2 X 4 P.R.T. AD STUD FOR DOOR FRAME 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as on "architectural work" under see. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. L � 40 L � V U 41 _ =Q^ 3 a�ooM O V 0 W J .iii. 0 .1... z o L, .= 11-i u 0 H 0 C J_ 0 C W1 N 1 5 5/8" X 20gci, MTL STUD z FRAMING. (IC50 #ER 4943 P) 0 Z w 6YP. BD. z J c to 00 DATE: N 6/I/Or0 LA SCALE: z 0 cn Zc DRAWN BY: Z roque AMJ lun 0 4y: 0 A V H as STT 0 1777 Q li r< ° b. D feI #P1386TRUT USE UNISTRUT 1-I005, A/ WIDE BASE FLANGE, AT � a 0 o � ° �+ GROSSES TRUSSES. rn [am 'C D Q GONG. FLOOR SLAB MAKE 6.C. TO PROVIDE BONDING ALL TRANSITIONS FLUSH. AGENT TO EXISTIN6 SLAB. MARBLE TILE TO MARBLE TILE SCALE, (18 BENT STEEL SADDLE A/ Al n' KAIKSOLT 1/2"0 X 2 1/4" =)MENT INTO CONCRETE 3O #2388) SELF TAPPING TEK SGREA SIDES _- .3TIN6 GONG. FLOOR. STEEL TUBE ANCHOR @ BASE DETAIL SCALE: 3" _ 13 SCALE: N.T.S. 3 5/5" X 20 (SAU6E DIA610NAL BRAGIN6. (10150 #ER 4843 P) 45" O.G. @) 45 ALTERNATE SIDES. SUSP. CLC. SYSTEM SEE REFLECTED CEILING PLAN, METAL STUDS (SEE SHT. AI) 5/8" TYPE "X" 6YP. BD. (TYP. BOTH SIDES). TOP OF INT. WALL BRACING DETAIL. VERIFY THAT THE SHOWN METHOD OF ATTACHMENT IS ACCEPTABLE WITH THE ON-SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. "" -TING METAL PAN DECK. CONT. 20 6A. SLOTTED DEEP LEG TRACK ATTR TO METAL STRAPS. — #10 SELF TAPPING TEK SCREAS @ 16" O.G. SCALE: 3" = 1'-0 5RAGIN6 DETAIL FOR FLOOR SUPPORTED FRAMING ONLY I UNISTRUT PI000 CLAMPED TO TOP CHORD OF JOIST A/ UNISTRUT BEAM CLAMP #P1386. USE UNISTRUT P1003, A/ AIDE BASE FLANGE, AT CONDITIONS AHERE SOFFIT GROSSES TRUSSES. - --1/2" MIN. FOR DEFLECTION. -----(2) #8 TEK SGREAS AT EA. CONNECTION. CONTINUOUS 22 6A. EXISTIN6 JOIST. 3 5/8" X 20 6A. METAL STUDS ® 16" O.G. 22 ATTACHMENT TO STRUCTURE ABOVE TENANT NEW TENANT TILE PLOOKIN6 PROVIDE PLUSH TRANSITION TO EXISTING MALL TILE 0 MALL 1/8" ALUMINUM TRANSITION STRI P EXIST. MALL TILE FLOORING ( VERIPY THICKNESS Q Q EXISS TING CONCRETE Q Q r TENANT TILE TO MALL FLOORING SCALE: N.T.S. DOOR- REFER TO DOOR SCHEDULE (SHEET AI) -HOLLOW METAL DOOR PRAME BY O.C. (RATED WHERE REQUIRED) •(I/4") F.R.T. SHIM (AS REQUIRED) -2 X 4 P.R.T. AD STUD FOR DOOR FRAME 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as on "architectural work" under see. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. L � 40 L � V U 41 _ =Q^ 3 a�ooM O V 0 W J .iii. 0 .1... z o L, .= 11-i u 0 H 0 C J_ 0 C W1 N 1 5 5/8" X 20gci, MTL STUD z FRAMING. (IC50 #ER 4943 P) 0 Z w 6YP. BD. TYP. HOLLOW METAL DOOR JAMB DETAIL ,2U. SCALE: 3" = 1'-71 o N Ln VERIFY THAT THE SHOWN METHOD OF ATTACHMENT IS ACCEPTABLE WITH THE ON-SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. BRAGIN6 AT 48" D.G. TO STRUCTURE, TYP. z J c to 00 DATE: N 6/I/Or0 LA SCALE: z 0 cn Zc DRAWN BY: Z roque AMJ lun 0 4y: 0 A V H as STT 0 1777 TO TOP CHORD OF J015T li r< ° b. BEAM CLAMP feI #P1386TRUT USE UNISTRUT 1-I005, A/ WIDE BASE FLANGE, AT � a 0 o M N � W �+ GROSSES TRUSSES. rn [am 'C � a o TYP. HOLLOW METAL DOOR JAMB DETAIL ,2U. SCALE: 3" = 1'-71 o N Ln VERIFY THAT THE SHOWN METHOD OF ATTACHMENT IS ACCEPTABLE WITH THE ON-SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. BRAGIN6 AT 48" D.G. TO STRUCTURE, TYP. 20 6A. DEEP LEG TRACK ATTACHED TO DECK EXISTIN6 JOIST. TYP. DIAL. BRACING CONN. TO DECK SCALE: N.T.S. c to 00 DATE: N 6/I/Or0 taN �� SCALE: 5 SHOWN 0 cn Zc DRAWN BY: Z roque AMJ lun PROJECT No.: 4y: Ln O + A as STT UNISTRUT 101000 CLAMPED 1777 TO TOP CHORD OF J015T li r< ° b. BEAM CLAMP feI #P1386TRUT USE UNISTRUT 1-I005, A/ WIDE BASE FLANGE, AT CONDITIONS WHERE SOPPIT �+ GROSSES TRUSSES. [am 'C .,I E c o° 2 #10 SCREWS AT EACH CONNECTION. 20 6A. DEEP LEG TRACK ATTACHED TO DECK EXISTIN6 JOIST. TYP. DIAL. BRACING CONN. TO DECK SCALE: N.T.S. jail 5 Ob DATE: SHEET: 6/I/Or0 SCALE: 5 SHOWN DRAWN BY: A8 AMJ PROJECT No.: DEM06024 PROVIDE CLEAR SILICONE BEAD PLASTIC LAM. FINISH (WHITE) I A -611 3/4" M.D.F. TOP �--- PROVIDE 3" DIA. HOLE IN O I DESKTOP W/ GROMMET (FOR CORDS) SCREW INTO WALL 5AGKIN6 12" O.G. O I 6YP. BD. WALL Z 3/4" M.D.F. END PIECES, ` (BOTH ENDS). 4 SECTION AT STOCK RM. DESK NOT USED 2X BLOGKI 6" WOOD GROWN MOULD I N6 ----__ 5/6" TYPE "X" 6YP. BD. OVER 3 5/6" X 20 6A. METAL STUD FRAMIN6 — NEW METAL SLATWALL ATTACHED TO WALL STANDARDS WITH 2 1/2" #6 POLISHED FLAT HEAD SCREWS— n Q � p Nh o0 35 SLATWALL DETAIL igg — (27 NOT SE UD SCALE: N.T.S. SCALE: 6.C,. TO INSTALL OWNER SUPPLIED 5AGKIN6 8 GROWN MOLDING WALL HOOK DETAIL STOCK ROOM CLO. (WHERE OCCURS) SEE REFLECTED GL6. PLAN FOR E.XAGT HE16HT. 2" MAX. I" X 4" FIRE TREATED HORIZ. (TYR) FIRE TREATED WOOD MOUNTING STRIPS AT 12" O.G. -J-BOXES 4 OUTLET ® +65 FOR STEREO MO. SEE SHT. EI - —_._..._.___.-__.__........_.._—.......__,...._._......-.____.___�)7ON /4" FIRE TREATED, 16" DEEP MELAMINE SHELVES ___...._.... P PARTICLE BD. SHELVING - iv 66' A.F.F. STANDARDS ® 16 O.G. $ - i I.D. STANDARDS ®I6" O.G.AGKETS. (TYP. OP 3) _ __.._ __._ _ .... .. ....,..._,...__........1AGKET9. " H.D. STANDARDS ® 16" 4"S SURFACEr_.............__....___-.___� O.G. dJ UNTED FINISHED NO _ ?LW_INTERS) B PAINTED. - ... �_.,..._.......__.--- TO METAL .____,..,__,.. ..__._.__..,;..__.._..._..._.. 4MIN6 @ 16" OR 24"-_.-......,..-.,---_..__�_...____...__..____.._ --_1' PLASTIC, LAM. GLAD DESK '• W/ n I I TOP 6 ENDS.40 J _ >4 (:LR. 12' HEAVY � �..... ww.__ . I ,. ... _. -1 IY STANDARDS OUT ry i I I I 3" DIA. HOLE IN DESK OM TOP OF 121-01, W/ TOP PLASTIC 6ROMET V6 PIECE. ATTACH TO I ®12" O.G. FOR r _...__.... -, ._._.._ _._.. ......... ............._..._..,. ,_,. CAMERA RT. W/ #4 5-1/2" LONG CI OD SCREWS. SYSTEMS P) Q FILE GAB. BY OWNER >. STEEL HANG ROD. R - �� - — - - — - — - — - — - — - — - 'P. OF 2) Q TEL. 8 POWER OUTLETS (SEE ELEC. DW6S.) dJ 6" BASE TYP_ ELEV. @ S.R. HANGRODS, SHELVING SCALE: \ w J SCALE: N.T.S. — - - 5'-Q" A.F.F. (4) CUSTOM WALL HOOKS SCREWED DIRECTI' TO METAL STUD ON OUTSIDE CORNER OF FITTING ROOM. 5GALE: 3" = I' -O" ------------- ------------- 1/2" METAL REVEAL I/2" PAINTED MF -I POWDER COATED METAL PANELS OVER 5/4" M.D.F. 34 STOREFRONT REVEAL DETAIL SCALE: N.T.S. SCALE: FULL INSIDE OF S' THUMBTURN COIL CORC WITH FIXTUF 3/6" THREADED ROD # -ITHROSO TO DECK OR STRUCTURE ABOVE. 6'-O" O.G. MAX. PAINT P-3 BROWN 4S OUTLET BOX ON fOP OF UNI -STRUT :HANNEL. PAINT P-3 ".HANNEL NUT 5/6" UNISTRUT CHANNEL. 'PAINT P-5 '-LAMP-ON MOUNTING 3RAGKET AND PORT FOR = I XTURE ®AR TYPE LAMP ..AMPHOLVER LIGHT FIXTURE MOUNTING DETAIL SCALE: N.T.S. SOLID WOOD BULLNOSE 3/8" WOOD FLOORING 8 3/4" P.R.T. STAINED - _\ PLYWOOD 8 5/8" TYPE "X" 6YP. BD. OVER 3-5/8" X 20 6A. METAL STUD FRAMIN6 ® 16" POWER `3" CONDUIT `SAFE BY OWNER. G.G. OUTLET +1611 , TO BOLT TO FLOOR. +IS" 25 TYP. ELEV. @ STOCKR NOTUSED 4" H16H RUBBER BASE IX 3/6" WOOD 5/8"ri TYPE "X" 6YP. BD. OVER 3-5/6" X 20 GA. METAL STUD FRAMING O CD DISPLAY PLATFORM DETAIL 33 M DESK SCALE: N.T.S. SCALE: N.T.S. 2" X 1-1/2" METAL ANGLE POWDER COATED 3/4" X 1 3/4" CHANNEL FIRE TREATED 5LOGKIN6 AS REQUIRED 10" HIGH POLISHED n DIAMOND PLATE 3 3/4" MDF. OVER 5/6" TYPE "X" GYP. BD. OVER 3-5/8" X 20 GA. METAL STUD FRAMIN6 0 16" O.G. SCALE: 3" = 1'-0" 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. LE d C V V Lo � 40 3 CoaoN � W J C ' LLm p 3 z° -v C ~ V � %AEo�c a a,o aea N N {A N � W D D Z a - z 0 W H uJ w O I JUN 6 ''06 0 I DATE: O I SHEET: Z O SCALE: 4 DRAWN BY: O I A9 B Z AMJ PROJECT No,: n _ + Q I 0 0 J i O - 0 H Z N Z m STOCK ROOM CLO. (WHERE OCCURS) SEE REFLECTED GL6. PLAN FOR E.XAGT HE16HT. 2" MAX. I" X 4" FIRE TREATED HORIZ. (TYR) FIRE TREATED WOOD MOUNTING STRIPS AT 12" O.G. -J-BOXES 4 OUTLET ® +65 FOR STEREO MO. SEE SHT. EI - —_._..._.___.-__.__........_.._—.......__,...._._......-.____.___�)7ON /4" FIRE TREATED, 16" DEEP MELAMINE SHELVES ___...._.... P PARTICLE BD. SHELVING - iv 66' A.F.F. STANDARDS ® 16 O.G. $ - i I.D. STANDARDS ®I6" O.G.AGKETS. (TYP. OP 3) _ __.._ __._ _ .... .. ....,..._,...__........1AGKET9. " H.D. STANDARDS ® 16" 4"S SURFACEr_.............__....___-.___� O.G. dJ UNTED FINISHED NO _ ?LW_INTERS) B PAINTED. - ... �_.,..._.......__.--- TO METAL .____,..,__,.. ..__._.__..,;..__.._..._..._.. 4MIN6 @ 16" OR 24"-_.-......,..-.,---_..__�_...____...__..____.._ --_1' PLASTIC, LAM. GLAD DESK '• W/ n I I TOP 6 ENDS.40 J _ >4 (:LR. 12' HEAVY � �..... ww.__ . I ,. ... _. -1 IY STANDARDS OUT ry i I I I 3" DIA. HOLE IN DESK OM TOP OF 121-01, W/ TOP PLASTIC 6ROMET V6 PIECE. ATTACH TO I ®12" O.G. FOR r _...__.... -, ._._.._ _._.. ......... ............._..._..,. ,_,. CAMERA RT. W/ #4 5-1/2" LONG CI OD SCREWS. SYSTEMS P) Q FILE GAB. BY OWNER >. STEEL HANG ROD. R - �� - — - - — - — - — - — - — - — - 'P. OF 2) Q TEL. 8 POWER OUTLETS (SEE ELEC. DW6S.) dJ 6" BASE TYP_ ELEV. @ S.R. HANGRODS, SHELVING SCALE: \ w J SCALE: N.T.S. — - - 5'-Q" A.F.F. (4) CUSTOM WALL HOOKS SCREWED DIRECTI' TO METAL STUD ON OUTSIDE CORNER OF FITTING ROOM. 5GALE: 3" = I' -O" ------------- ------------- 1/2" METAL REVEAL I/2" PAINTED MF -I POWDER COATED METAL PANELS OVER 5/4" M.D.F. 34 STOREFRONT REVEAL DETAIL SCALE: N.T.S. SCALE: FULL INSIDE OF S' THUMBTURN COIL CORC WITH FIXTUF 3/6" THREADED ROD # -ITHROSO TO DECK OR STRUCTURE ABOVE. 6'-O" O.G. MAX. PAINT P-3 BROWN 4S OUTLET BOX ON fOP OF UNI -STRUT :HANNEL. PAINT P-3 ".HANNEL NUT 5/6" UNISTRUT CHANNEL. 'PAINT P-5 '-LAMP-ON MOUNTING 3RAGKET AND PORT FOR = I XTURE ®AR TYPE LAMP ..AMPHOLVER LIGHT FIXTURE MOUNTING DETAIL SCALE: N.T.S. SOLID WOOD BULLNOSE 3/8" WOOD FLOORING 8 3/4" P.R.T. STAINED - _\ PLYWOOD 8 5/8" TYPE "X" 6YP. BD. OVER 3-5/8" X 20 6A. METAL STUD FRAMIN6 ® 16" POWER `3" CONDUIT `SAFE BY OWNER. G.G. OUTLET +1611 , TO BOLT TO FLOOR. +IS" 25 TYP. ELEV. @ STOCKR NOTUSED 4" H16H RUBBER BASE IX 3/6" WOOD 5/8"ri TYPE "X" 6YP. BD. OVER 3-5/6" X 20 GA. METAL STUD FRAMING O CD DISPLAY PLATFORM DETAIL 33 M DESK SCALE: N.T.S. SCALE: N.T.S. 2" X 1-1/2" METAL ANGLE POWDER COATED 3/4" X 1 3/4" CHANNEL FIRE TREATED 5LOGKIN6 AS REQUIRED 10" HIGH POLISHED n DIAMOND PLATE 3 3/4" MDF. OVER 5/6" TYPE "X" GYP. BD. OVER 3-5/8" X 20 GA. METAL STUD FRAMIN6 0 16" O.G. SCALE: 3" = 1'-0" 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. LE d C V V Lo � 40 3 CoaoN � W J C ' LLm p 3 z° -v C ~ V � %AEo�c a a,o aea N N {A N � W D D Z a - z 0 W H uJ w JUN 6 ''06 DATE: SHEET: Z 6/I/Oro SCALE: AP SHOWN DRAWN BY: A9 B Z AMJ PROJECT No,: DEM06024 l7 Z J H Z N Z 08 0 N 0 ' m � fV N oQ Ito O Q1 C O _Q+ T lV c00 C O -N V E Q 4M o oa,a^c zMo Ln a� Ln to H pz' a a as �;,t•Y.1y�i �1 d � >,:r IM "xh,3'fl a w h 1i M t !; C r,K 0 ,y !•- 113 JUN 6 ''06 DATE: SHEET: 6/I/Oro SCALE: AP SHOWN DRAWN BY: A9 AMJ PROJECT No,: DEM06024 NOTE: -INTERNALLY LINED DUCTWORK, IS PERMITTED FOR ACOUSTICAL PURPOSES, HOWEVER IT IS NOT A SUBSTITUTE FOR EXTERNAL INSULATION WRAP REQUIRED BY LANDLORD. -ALL UNEXPOSED SUPPLY AIR DUCTWORK MUST BE EXTERNALLY INSULATED WITH VAPOR BARRIER. -EXTERNALLY INSULATED FLEXIBLE DUCT, NOT TO EXCEED 5'-0 " IN LENGTH, MAY BE USED FOR VERTICAL CONNECTIONS TO SUPPLY DIFFUSERS ONLY. O1 MECHANICAL FLOOK PLAN Q SHEET: z b/OI /Ob SCALE: Y tj 1! mckon,r mmoo 6 ri6vvR m6mm 1/4"=V-0" NOTE: TENANT'S HVAC SYSTEM SHALL BE REQUIRED TO INTERFACE WITH LANDLORD'S ENERGY MANAGEMENT SYSTEM. CONTACT MALL REPRESENTATIVE FOR REQUIRED INSTALLATION CONTRACTOR AND OTHER PERTINENT INFORMATION. (INSTALLATION IS AT TENANT'S EXPENSE). MECHANICAL SYMBOLS EXISTING METAL DUCTWORK MECHANICAL EQUIPMENT DESIGNATION e NEW SHEET METAL DUCTWORK CONNECT TO EXISTING DUCTWORK TRANSITION O MANUAL VOLUME DAMPER DUCT BRANCH TAKE—OFF AFF ABOVE FINISHED FLOOR BHP BRAKE HORSEPOWER THERMOSTAT — ELECTRIC BTU BRITISH THERMAL UNIT FIRE DAMPER CFM CUBIC FEET PER MINUTE DB DRY BULB VARIABLE AIR VOLUME UNIT EAT ENTERING AIR TEMPERATURE HZ FREQUENCY CEILING EXHAUST FAN LAT LEAVING AIR TEMPERATURE OA OUTSIDE AIR LAY—IN SUPPLY DIFFUSER RTU ROOFTOP UNIT TYP TYPICAL WC WATER COLUMN LAY—IN RETURN DIFFUSER WB WET BULB 17 DIFFUSER DESIGNATION AND CFM CFM ?? NOTE DESIGNATION QREVISION DESIGNATION THIS PROJECT MAY NOT USE EVERY SYMBOL OR DEVICE APPEARING ON THIS LEGEND. MECHANICAL PLAN KEY NOTES M1 INSTALL TRANE FURNISHED TEMPERATURE SENSOR COMPATIBLE WITH EXISTING BUILDING ENERGY MANAGEMENT SYSTEM. MOUNT T—STAT AT 48" A.F.F. CONTRACT LANDLORD APPROVED CONTROLS CONTRACTOR TO CONNECT SENSOR TO BUILDING ENERGY MANAGEMENT SYSTEM. PROVIDE ALL CONTROL WIRING WITHIN CONDUIT FOR A COMPLETE AND FUNCTIONAL SYSTEM. �2 PROVIDE NEW VARIABLE AIR VOLUME TERMINAL UNIT. PROVIDE MINIMUM FOUR EQUIVALENT DIAMETERS OF STRAIGHT DUCT IMMEDIATELY UPSTREAM OF VAV TERMINAL UNIT. PROVIDE MEDIUM PRESSURE DUCT UPSTREAM OF VAV TERMINAL UNIT. REUSE EXISTING TAP IF POSSIBLE. MAINTAIN MANUFACTURER RECOMMENDED SERVICE CLEARANCE AROUND THE UNIT. COORDINATE WITH MALL REPRESENTATIVE FOR EXISTING TAP LOCATION AND MODIFICATION TO MALL SUPPLY DUCT. M3 PROVIDE CEILING MOUNTED EXHAUST FAN. TRANSITION FROM FAN DISCHARGE TO DUCT SIZE SHOWN AND EXTEND TO EXISTING MALL EXHAUST DUCT. REFER TO EXHAUST AND VENTILATION FAN SCHEDULE FOR ADDITIONAL REQUIREMENTS. COORDINATE WITH MALL REPRESENTATIVE FOR MODIFICATION TO MALL EXHAUST DUCT. ® MOUNT BOTTOM OF DUCTWORK AT 12'-6" AFF. FIELD VERIFY PRIOR TO BID. 0 PROVIDE 10"X10" TRASNFER AIR OPENING IN WALL ABOVE LAY—IN CEILING. © EXISTING LANDLORD SUPPLY DUCT SHALL REMAIN IN PLACE. in EXISTING LANDLORD EXHAUST DUCT SHALL REMAIN IN PLACE. ® EXISTING TRANSFER AIR OPENING WITH FIRE DAMPER AND WIRE MESH SCREEN SHALL REMAIN IN PLACE. ❑9 PROVIDE RUSKIN FD60 1-1/2 HOUR UL555 RATED FIRE DAMPER ASSEMBLY iN WALL. INSTALL FIRE DAMPER IN STRICT ACCORDANCE WITH DAMPER MANUFACTURER'S INSTALLATION INSTRUCTIONS. DEMOLITION NOTES REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, HANGERS, SUPPORTS, PIPING, AND ACCESSORIES SERVING THIS SPACE ONLY AND NOT INDICATED TO REMAIN. CONSULT MALL OPERATIONS MANAGER OR MALL ENGINEER FOR DETAILS AND INFORMATION REGARDING HVAC AND EXHAUST SYSTEMS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. L.L. APPROVED AS (VOTED 6/9/2006 O Larson Binkley, Inc. 6363 College Blvd., Suite 400 Overland Park, Kansas 66211 Florida Certificate of Authorization Number 8039 Christopher R. Larson, PE0043082 !33-26213—T91b-2831F 913—larsony.com L COPYRIGHT �ZoG r I 2006 ohn C. Coulter,, PE0030426 2246 These drawings and specifications are copyrighted and subset to " 4?11 protection as an "architectural work" under age. 10othi copyright cot. 17 u.S.C. M amended deoember 1990. Ths protection Includes, without limitation, the overall form, arrangement and aomposltlan of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result In cessation of construction, building seizure, and/or monetary llobility. 4 L ai U C a woo DUO UJ i•— d) 0 J v C o , 0 � Z M ._ r° a� a Eos= N 0 a. M IiA 1`4 4A tA ATE. SHEET: b/OI /Ob SCALE: DRAWN BY., M 1 AN IrItQIEC1' No.: OW"024 VAV TERMINAL UNIT SCHEDULE MARK (VAV-#) 1 MANUFACTURER TRANE MODEL VCCF012 UNIT SIZE 12 INLET SIZE 12 MAXIMUM AIR FLOW CFM 2000 MINIMUM AIR FLOW CFM 795 ACCESSORIES NOTES 1-5 ACCESSORIES: NOTES: 1) PROVIDE CASING WITH 1/2" MATT FACED INSULATION. 2) PROVIDE ELECTRONIC ACTUATOR. 3) PROVIDE 24 VOLT CONTROL TRANSFORMER. 4) PROVIDE TOGGLE DISCONNECT SWITCH. 5) FURNISH TEMPERATURE SENSOR (WITH SETPOINTADJUSTMENT) AND CONTROLLER COMPATIBLE WITH EXISTING BUILDING ENERGY MANAGEMENT SYSTEM TO BE INSTALLED BY MECHANICAL CONTRACTOR IN FIELD. EXHAUST AND VENTILATION FAN SCHEDULE MARK (EF;q ASHRAE 62--2001 OUTSIDE AIR REQUIREMENTS MANUFACTURER LOREN 555K - MODEL - ___C_E_ffFff1VUGAL TYPE D DRIVE TYPE PERFORMANCE AIR FLOW (CFM) DIR CT 100 EXT. STATIC (IN W.C.) 0.25 FAN SPEED (RPM) ELECTRICAL VOLTS/0/HZ 1500 120/1/60 FAN MOTOR HP 50F FAN MOTOR WATTS 66.6 ACCESSORIES BD, DS APPROX. WEIGHT (LBS) 15 SERVES RESTROOM NOTES ACCESSORIES: BD-BACKDRAFT DAMPER, DS -DISCONNECT SWITCH, NOTES: 1 INTERLOCK EXHAUST FAN WITH LIGHT SWITCH. GRILLE REGISTERRI,D. DIFFUSER SCHEDULE ASHRAE 62--2001 OUTSIDE AIR REQUIREMENTS MARK A B C D MANUFACTURER TITUS TITUS TITUS TITUS MODEL TMSA 50F 50F TYPE SQUARE CONE EG CRATE RETURN EGGCRATE RETURN EGGCRATE RETURN GRILLE GRILLE GRILLE NECK SIZE L"XW" PER PLAN 22"X22" 22"X10" 22'XIU' FACE SIZE L" XW" 24"X24" 24"X24" 24"X12" 24"X12" FRAME TYPE LAY4N LAY -IN LAY -IN LAY -IN FINISH WHITE WHITE WHiTE WHITE NOISE CRITERIA LEVEL <30 <30 <3O <30 ACCESSORIES 'iRM NOTES ACCESSORIES: TRM-RAPID MOUNT FRAME OUTSIDE AIR REQUIREMENTS ROOM PURPOSE GROSS FLOOR AREA SQ. FT. ASHRAE 62--2001 OUTSIDE AIR REQUIREMENTS SYSTEM NUMBER ACTUAL OUTSIDE AIR CFM CFM SF CFM SALES 2,300 0.30 690 VAV-1 795 NON -SALES 700 0.15 105 TOTAL 795 TOTAL 795 U.L. LISTED FIRE DAMPER FUSIBLE LINK PROVIDE CLEARANCE FOR EXPANSION ON TOP, BOTTOM, AND SIDES OF SLEEVE. REFER TO MANUFACTURER'S REQUIREMENTS. ACCESS DOOR. LABEL "FIRE DAMPER". PROVIDE MOUNTING HARDWARE ATTACHED TO SLEEVE AS REQUIRED TO MAINTAIN MANUFACTURER'S LISTING. DO NOT ATTACH ANGLES TO WALL. ALL FIRE DAMPERS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH FIRE DAMPER MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS TO MAINTAIN U.L. LISTING. 03VERTICAL FIRE DAMPER DETAIL NOT TO SCALE MECHANICAL SPECIFICATIONS PROVIDE EQUIPMENT INDICATED ON THE DRAWINGS, AND AS REQUIRED FOR A COMPLETE FUNCTIONING SYSTEM. DEFINITIONS: FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR INSTALLATION. INE LL MEANS TO PLACE IN POSITION AND MAKE CONNECTIONS FOR SERVICE OR USE. PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE. WARRANTY: PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT. PROVIDE A SEPARATE LINE ITEM DEDUCT AMOUNT ON THE PROPOSAL FORM TO DELETE WARRANTY SERVICE, AT THE OWNER'S OPTION. COORDINATION: COORDINATE WITH THE WORK OF OTHER TRADES, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. DUCT DIMENSIONS: UNLESS OTHERWISE NOTED, DUCT DIMENSIONS ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. SHEETMETAL DUCTWORK: PROVIDE SHEETMETAL DUCTWORK FABRICATED AND INSTALLED IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS, FOR 1" W.G. PRESSURE CLASS, SEAL CLASS "A" DOWNSTREAM OF VAV TERMINAL UNIT AND B" W.G. PRESSURE CLASS, SEAL CLASS "A" UPSTREAM OF VAV TERMINAL UNIT, SHEETMETAL SHALL BE GALVANIZED SHEET STEEL OF LOCK FORMING QUALITY, WITH G90 ZINC COATING. SHEET STEEL SHALL COMPLY WITH ASTM A653 STANDARD SPECIFICATION FOR STEEL SHEETMETAL, ZINC COATED (GALVANIZED) OR ZINC -IRON ALLOY -COATED (GALVANNEALED) BY THE HOT DIP PROCESS, AND A924 STANDARD SPECIFICATION FOR GENERAL REQUIREMENTS FOR SHEET, METALLIC -COATED BY THE HOT DIP PROCESS. ALL ANGLE IRON USED FOR SUPPORT SHALL BE GALVANIZED. CONNECTIONS TO WALLS OR FLOOR SHALL BE AIR TIGHT WITH ANGLE IRON AND CAULKING. SEAL ALL DUCT SEAMS, TRANSVERSE AND LONGITUDINAL, AIR TIGHT. PROVIDE TURNING VANES AT ALL 900 ELBOWS. TRAPEZE DUCT HANGERS: PROVIDE MINIMUM 1" X 2" X 1" X 18 GAUGE CHANNELS WITH MINIMUM 1 " X 18 GAUGE STRAPS . TO STRUCTURAL SUPPORT. ROUND SHEETMETAL DUCT: PROVIDE SPIRAL SEAM (ALL SIZES) OR SNAP LOCK (DUCT SIZES UP TO 10") GALVANIZED STEEL COMPLYING WITH SMACNA STANDARDS. SPIRAL SEAM DUCTWORK SHALL HAVE SMACNA SEAM TYPE RL -1. DUCT SEALANT: PROVIDE POLYMERIC RUBBER TYPE SEALANT FOR USE ON BOTH INTERIOR LOCATED DUCTWORK AND DUCTWORK EXPOSED TO OUTDOOR CONDITIONS. SEALER SHALL HAVE HIGH BONDING STRENGTH FOR SURE. FIRST TIME SEALING OF JOINTS IN LOW, MEDIUM, AND HIGH PRESSURE DUCT SYSTEMS. SEALER SHALL BE HIGH IN SOLID CONTENT. PROVIDE A TWO PART TAPE SEALING SYSTEM, CONSISTING OF WOVEN FIBER TAPE IMPREGNATED WITH A GYPSUM MINERAL COMPOUND, AND A MODIFIED ACRYLIC/SILICONE ACTIVATOR THAT REACTS EXOTHERMICALLY WITH THE TAPE. TWO PART TAPE SEALING SYSTEM MUST BE RATED FOR BOTH INDOOR AND OUTDOOR APPLICATION. TAPE SHALL NOT CONTAIN ASBESTOS. FLEXIBLE DUCT: PROVIDE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH 1" THICK 1 PCF FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPOR BARRIER. FLEXIBLE DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50, AND SHALL BE RATED FOR MiNIMUM 2" W.G. PRESSURE AND 0 TO 2509F TEMPERATURE. PROVIDE SCREW -OPERATED METAL ADJUSTABLE CLAMPING DEVICES. USE TWIST -LOCK TAP COLLARS AT CONNECTIONS INTO SHEETMETAL DUCTWORK. MAXIMUM EXTENDED LENGTH OF FLEXIBLE DUCT SHALL NOT EXCEED 6 FEET. DUCT INSULATION (ALL SUPPLY DUCT UPSTREAM OF VAV TERMINAL UNIT): PROVIDE MINIMUM 2" THICK BLANKET TYPE FIBERGLASS INSULATION COMPLYING WITH ASTM C-553, TYPE II, WITH FACTORY APPLIED KRAFT BONDED TO ALUMINUM FOIL, REINFORCED WITH FIBERGLASS VAPOR BARRIER/JACKET. JACKET SHALL CONFORM TO ASTM C-1136, TYPE 11. INSTALLED R VALUE SHALL BE 6 OR HIGHER WITH A 0.75 PCF DENSITY. BELLMOUTH OR CONICAL TAP BY LANDLORD HVAC CONTRACTOR AT TENANT EXPENSE (IF NOT EXISTING). LANDLORD SUPPLY DUCT MINIMUM 4 DUCT DIAMETER - STRAIGHT SECTION (SHALL BE SAME SIZE AS THE BOX INLET). FLEXIBLE DUCT NOT ALLOWED. DUCT LINER (LOW PRESSURE SUPPLY DUCTWORK DOWNSTREAM OF VAV TERMINAL UNIT): PROVIDE MINIMUM 1-1/2" THICK, 3 PCF DENSITY, NEOPRENE COATED, LONG TEXTILE FIBER TYPE DUCT LINER, WITH COATING ON THE AIR STREAM SIDE CONFORMING TO NFPA 90A. DUCT LINER ADHESIVE SHALL BE AS RECOMMENDED BY DUCT LINER MANUFACTURER, AND SHALL COMPLY WITH ASTM C-916. DUCT LINER FASTENERS SHALL COMPLY WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS", LATEST EDITION. THERMAL CONDUCTIVITY SHALL BE EQUAL TO OR LESS THAN 0.26 AT 75F. RECTANGULAR VOLUME DAMPERS: PROVIDE MINIMUM 16 GAUGE GALVANIZED STEEL CHANNEL FRAME, 16 GAUGE GALVANIZED STEEL BLADES, MINIMUM T HEXAGONAL AXLE, BOLDED SYNTHETIC BEARINGS, WITH 3/8" SQUARE PLATED STEEL CONTROL SHAFT. LINKAGES SHALL BE CONCEALED IN THE FRAME. OPERATING SHAFT SHALL EXTEND BEYOND FRAME AND DUCT TO A LOCKING QUADRANT WITH ADJUSTABLE LEVER. MAXIMUM BLADE WIDTH SHALL NOT EXCEED 6". DUCT TURNING VANES: PROVIDE FABRICATED TURNING VANES AND VANE RUNNERS, CONSTRUCTED IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS". PROVIDE TURNING VANES CONSTRUCTED OF CURVED BLADES, SUPPORTED WITH BARS PERPENDICULAR TO BLADES, AND SET INTO SIDE STRIPS SUITABLE FOR MOUNTING IN DUCTWORK. FOLLOW SMACNA GUIDELINES FOR SPACING SUPPORT, AND CONSTRUCTION. ALL BLADES SHALL BE DOUBLE THICKNESS AIRFOIL TYPE. FLEXIBLE DUCT CONNECTORS: PROVIDE U.L. LABELED 30 OUNCE NEOPRENE COATED FIBERGLASS FABRIC DUCT CONNECTORS AT DUCT CONNECTIONS TO ALL VIBRATING EQUIPMENT. DUCT ACCESS DOORS: PROVIDE HINGED ACCESS DOORS IN DUCTWORK WHERE REQUIRED FOR ACCESS TO EQUIPMENT. PROVIDE INSULATED ACCESS DOORS FOR INSULATED DUCTWORK. CONSTRUCT OF SAME OR THICKER GAUGE SHEETMETAL AS DUCT IN WHICH IT IS INSTALLED. PROVIDE FLUSH FRAMES FOR UNINSULATED DUCTS, AND EXTENDED FRAMES FOR EXTERNALLY INSULATED DUCTS. PROVIDE CONTINUOUS HINGE ON ONE SIDE, WITH ONE HANDLE -TYPE LATCH FOR ACCESS DOORS 12" HIGH AND SMALLER, AND TWO HANDLE -TYPE LATCHES FOR LARGER ACCESS DOORS. CURTAIN FIRE DAMPERS: PROVIDE WHERE INDICATED CURTAIN TYPE FIRE DAMPERS, SUITABLE FOR VERTICAL OR HORIZONTAL INSTALLATION AS REQUIRED FOR THE LOCATION SHOWN. CURTAIN FIRE DAMPERS SHALL HAVE MINIMUM 24 GAUGE GALVANIZED STEEL BLADES, COMPLETELY OUT OF THE AIR STREAM. CURTAIN FIRE DAMPERS SHALL CONFORM TO UL STANDARD 555, WHICH INCLUDES TESTING TO CLOSE UNDER DYNAMIC AIRFLOW CONDITIONS, AND SHALL BE UL LABELED AS A DYNAMIC RATED FIRE DAMPER. DAMPERS SHALL BE 1-1/2 OR 3 HOUR RATED AS REQUIRED BY LOCATION, AND SHALL HAVE A 217F FUSIBLE LINK. TESTING AND BALANCING: TEST AND ADJUST ALL MECHANICAL SYSTEMS AND EQUIPMENT TO ASSURE PROPER BALANCE AND OPERATION. PERFORM TESTS IN ACCORDANCE WITH THE MOST CURRENT NEBB OR AABC, AND ASHRAE STANDARDS. ELIMINATE OBJECTIONABLE NOISE AND VIBRATION, AND ASSURE PROPER FUNCTION OF CONTROLS. BALANCING CONTRACTOR SHALL BE AN INDEPENDENT CERTIFIED TEST AND BALANCE CONTRACTOR, WITH NEBB OR AABC CERTIFICATION. SUBMIT COMPLETED AND CERTIFIED TEST AND BALANCE REPORT TO OWNER'S REPRESENTATIVE. BALANCE ALL SYSTEMS TO WITHIN 5X OF AIR FLOWS INDICATED ON THE DRAWINGS, AND REPORT ALL DISCREPANCIES TO HVAC INSTALLER FOR CORRECTION. MARK FINAL BALANCE POSITIONS ON DAMPERS WITH PERMANENT MARKER. DUCT CONSTRUCTION TO VAV BOX INLET: PRESSURE CLASS 6 -INCH W.C. SEAL CLASS "A." VAV BOX TERMINAL THERMOSTAT (BY VAV BOX TERMINAL MFR) 02MALL CONNECTION SETUP NOT TO SCALE LOW PRESSURE DUCTWORK L.L. NO EXCEPTIONS TAKEN 6/9/2006 GENERAL NOTES A. CONTRACTORS AND SUB -CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. B. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. C. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. D. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY. PURCHASE ALL PERMITS ASSOCIATED WiTH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. E. PRIOR TO CONSTRUCTION / BID, THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF ANY LANDLORD PROVIDED OR EXISTING OUTSIDE AIR INTAKE THROUGH ROOF, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK, ETC. THE CONTRACTOR SHALL FIELD VERIFY ANY CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY ARCHITECT IMMEDIATELY. F. USE OF COMBUSTIBLE MATERIALS IS NOT ALLOWED IN THE RETURN AIR PLENUM. MATERIALS USED IN THE PLENUM SHALL HAVE FLAME SPREAD RATING NOT TO EXCEED 25, AND SMOKE DEVELOPED RATING NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. ALL EXPOSED WIRING IN THE PLENUM SHALL BE PLENUM RATED. TRANE HVAC EQUIPMENT PACKAGE I INCLUDES ALL TRANE HVAC EQUIPMENT AND RELATED ACCESSORIES SUCH AS CURBS, THERMOSTATS, HEATERS, ETC., AS SPECIFIED ON THE PLANS AND SPECIFICATIONS FOR PACIFIC SUNWEAR. FOR COMPLETE INFORMATION ON THE PACIFIC SUNWEAR EQUIPMENT PACKAGE, CONTACT THE NATIONAL ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. PATRICK BRONSON THE TRANE COMPANY 17760 ROWLAND STREET CITY OF INDUSTRY, CA 91748 PHONE: (866) 882-1611 PHONE: (626) 435-1176 FAX: (626) 913-2489 EMAIL: PBRONSON®TRANE.COM ANY CHANGES OR VARIATIONS TO THE ORIGINAL EQUIPMENT PACKAGE THAT WOULD AFFECT THE HVAC EQUIPMENT PACKAGE SHOULD BE BROUGHT TO THE ATTENTION OF THE ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. THE GENERAL OR INSTALLING CONTRACTOR PURCHASES THE EQUIPMENT PACKAGE DIRECTLY FROM THE TRANE COMPANY. THE HVAC CONTRACTOR WILL BE RESPONSIBLE FOR FIRST YEAR LABOR WARRANTY. DELIVERY COORDINATION, RECEIVING AND INSTALLATION AS DESCRIBED IN THE SPECIFICATIONS. TRANE WARRANTIES ALL PARTS FOR A PERIOD OF ONE(1) YEAR FROM INITIAL STARTUP OR 18 MONTHS FROM THE DATE OF SHIPMENT. WHICH EVER OCCURS FIRST. CERTAIN EQUIPMENT HAVE COMPONENTS THAT INCLUDE AND EXTEND WARRANTY LONGER THAN ONE (1) YEAR. TRANE PARTS WARRANTIES BELONG TO THE EQUIPMENT OWNER. CONTROL ENCLOSUF PROVIDE SUFFICIENT CLEARANCE TO PERI ACCESS TO CONTRC PRIMARY AIR INLET. OVAV TERMINAL UNIT DETAIL NOT TO SCALE _OW PRESSURE DUCTWORK 2246 COPYRIGHT NOTICE: These drawings and specifications ars copyrighted and subt�ot to 0opyright protection as an "architectural work" un er sec. 1OR of the copyright act. 17 u.S.C. As amended deosmber 1990. The protection Includes, without limitation. the overall form, arrangement and composition of spaces, and elements of the design. =composition protection, unauthorized use of these drawings and speolflaatlons may result In osseation of construction. building seizure, and/or monetary liability. 0 c Go L L ■ sl■s V L a) 40 C V 4) C 0 0 0 N t W IT DATE. b/OI /Ob SHEET: SG4LE. NOT TO WALL DRANK W. AN M2 PNf)AEt:T No.: 1�M080Z4 PLUMBING SPECIFICATION I THE WORK INCLUDES MODIFICATION TO THE EXISTING PLUMBING SYSTEM AND PROVIDING NEW MATERIALS, FITTINGS AND ACCESSORIES NECESSARY FOR A COMPLETE FUNCTIONING PLUMBING SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND/OR ORDINANCES AND IS SUBJECT TO INSPECTION. HOOK—UP CHARGES, PERMITS AND ALL OTHER EXPENSES RELATED TO A COMPLETE AND FUNCTIONING PLUMBING SYSTEM ARE INCLUDED AS A PART OF THIS SECTION. THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK REQUIRED FOR THE PROJECT. THE DRAWINGS FOR PLUMBING WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, FIXTURES AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. REFER TO MANUFACTURER'S STANDARD ROUGH—IN DRAWINGS FOR PLUMBING FIXTURE INSTALLATION REQUIREMENTS. COMPLY WITH ALL APPLICABLE ADA INSTALLATION REQUIREMENTS. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, AND WiTH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. PiPING SYSTEMS — GENERAL: ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LINES AND SUPPORTED AND ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. INSTALL AS REQUIRED TO MEET ALL CONSTRUCTION CONDITIONS AND .TO ALLOW FOR INSTALLATION OF OTHER WORK SUCH AS DUCTS AND ELECTRICAL CONDUIT. AT ALL CONNECTIONS BETWEEN FERROUS PIPING AND NONFERROUS PIPING, PROVIDE AN ISOLATING DIELECTRIC UNION. ALL HANGERS SHALL BE COMPATIBLE WITH PIPING MATERIAL TO PREVENT CORROSION. PROVIDE ALL FITTINGS, ACCESSORIES. OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED. FIXTURES/EQUIPMENT FURNISHED BY OTHERS: PLUMBING CONTRACTOR SHALL PROVIDE UTILITY CONNECTIONS REQUIRED SUCH AS WATER, GAS, AIR, SUPPLIES, WASTE OUTLET, TRAPS, ETCETERA AT ALL PLUMBING TYPE FIXTURES OR EQUIPMENT FURNISHED BY OWNER, GENERAL CONTRACTOR, EQUIPMENT SUPPLIER, ETCETERA. INCLUDED ARE STOP VALVES, ESCUTCHEONS, AND CHROME PLATED BRASS TUBING WITH COMPRESSION FITTINGS. SEWER AND WASTE PIPING: PROVIDE ALL DRAINS AND SEWERS WITHIN THE LEASED SPACE WITH CONNECTION TO THE LANDLORD'S EXISTING DRAINAGE SYSTEMS ON-SITE. SANITARY DRAINAGE PIPING ABOVE FLOOR SHALL BE HUBLESS CAST-IRON PIPE, FITTINGS AND CONNECTIONS. SANITARY DRAINAGE PIPING BELOW GRADE SHALL BE SERVICE—WEIGHT HUB AND SPIGOT TYPE CAST—IRON WITH NEOPRENE GASKET JOINTS. ALL DRAINAGE PIPING SHALL BE UNIFORMLY PITCHED, 1/4' PER FOOT FOR PIPE SIZES 3" AND SMALLER, 1/8" PER FOOT FOR PiPE SIZES 4" AND LARGER, UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS. PVC PIPING IS NOT PERMITTED. VENTS: PROVIDE A COMPLETE SYSTEM OF STANDARD WEIGHT CAST IRON NO—HUB VENT RISERS. THE VENT SYSTEM SHALL BE CARRIED THROUGH THE ROOF WITH APPROPRIATE FLASHING. CLEANOUTS: PROVIDE CLEANOUTS AT THE END OF EACH HORIZONTAL RUN, AND AT THE BASE OF ALL VERTICAL WASTE AND DRAIN PIPES. CLEANOUTS SHALL BE OF THE SAME SIZE AS THE PIPES THEY SERVE, CONFORMING TO CODE REQUIREMENTS. PROVIDE SUITABLE WALL OR FLOOR CLEANOUTS WITH ACCESSORIES TO OBSCURE FROM VIEW. WATER DISTRIBUTION PIPING: LAYOUT WATER PIPING SO THAT THE ENTIRE SYSTEM CAN BE DRAINED. ABOVE GRADE HOT AND COLD WATER PIPING SHALL BE 1/2- MINIMUM TYPE "L" COPPER TUBING WITH WROUGHT COPPER FITTINGS AND SWEAT CONNECTIONS. BELOW GRADE HOT AND COLD WATER PIPING SHALL BE 1/2- MINIMUM TYPE "K" COPPER TUBING WiTH WROUGHT COPPER FITTINGS, AND SWEAT CONNECTIONS. PROVIDE WATER HAMMER ARRESTORS AT EACH FIXTURE OR GROUP OF FIXTURES AS REQUIRED. INSTALL CHROME PLATED BRASS ESCUTCHEON PLATES AT ALL PENETRATIONS THROUGH FINISHED SURFACES (INCLUDING CABINET INTERIORS). USE TIN—ANTIMONY SOLDER, 95/5 FOR ALL SWEAT FITTINGS OF COPPER PIPING. PIPE INSULATION: FLEXIBLE, ONE PIECE, EXPANDED CLOSED—CELL ELASTOMERIC PIPE INSULATION WITH REQUIREMENTS COMPLYING WITH ASTM C 518, SELF—SEALING, WITH A MAXIMUM VAPOR TRANSMISSION RATING OF 0.20 PERM WHEN TESTED ACCORDING TO ASTM E 95. THERMAL CONDUCTIVITY (K VALVE) SHALL NOT EXCEED 0.27 BTU * IN. / HR. * FT2 * 'F AT 75*F MEAN TEMPERATURE, AND INSULATION AND JACKET SHALL BE RATED FOR OPERATING TEMPERATURES FROM 40'F TO 189F. PROVIDE INSULATION THICKNESS AS INDICATED. DOMESTIC COLD WATER PIPING 2" AND SMALLER: 1/2" THICKNESS CONDENSATE PIPING: 1/2" THICKNESS DOMESTIC HOT WATER PIPING 2" AND SMALLER: 1/2" THICKNESS HOT WATER AND WASTE PIPING BELOW HANDICAP LAVATORIES/SINKS SHUTOFF VALVES, WITH UNIONS SHALL BE PROVIDED FOR SERVICE TO EACH PLUMBING FIXTURE, FOOD SERVICE EQUIPMENT ITEM OR OTHER EQUIPMENT ITEM, TO FACILITATE ISOLATION FOR REPAIR OR REPLACEMENT. VALVES SHALL BE EQUAL TO CRANE #9302-9322 BALL VALVE. CONSTRUCTION — TWO PIECE, BRONZE BODY, FULL PORTED, CHROME PLATED BRASS BALL, REPLACEABLE "TEFLON OR TFE" SEATS AND SEALS. RATING — 150 PSI WSP, 600 PSI WOG. CONNECTIONS — SOLDER OR THREADED ENDS TO MATCH PIPING, STANDARDS COMPLIANCE — BRONZE OR BRASS VALVES: MSS—SP-110. ACCESS PANELS SHALL BE PROVIDED WHERE CONCEALED CONTROL DEVICES, VALVES, ETCETERA ARE CONCEALED WITHIN WALLS. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS POSSIBLE THROUGH LAY—IN SUSPENDED CEILINGS, ACCESS PANELS ARE NOT REQUIRED. INSTALLATION: THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP PIPE OPENINGS TO EXCLUDE DIRT UNTIL FIXTURES ARE INSTALLED AND FINAL CONNECTIONS HAVE BEEN MADE. PROCEED AS RAPIDLY AS CONSTRUCTION WILL PERMIT. SET FIXTURES LEVEL AND IN PROPER ALIGNMENT. INSTALL SUPPLIES IN PROPER ALIGNMENT WITH FIXTURES. INSTALL SILICONE SEALANT BETWEEN FIXTURES AND ADJACENT MATERIAL, FOR SANITARY JOINT, AND OMIT ESCUTCHEONS. REPAIR EXISTING PLUMBING SYSTEM COMPONENTS DAMAGED BY CONSTRUCTION OPERATIONS AND RESTORE TO ORIGINAL CONDITIONS. TEST WATER SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE, FOR FOUR (4) HOURS MINIMUM. WHEN TESTING INDICATES MATERIALS OR WORKMANSHIP IS DEFICIENT, REPLACE OR REPAIR AS REQUIRED, AND REPEAT TEST UNTIL STANDARDS ARE ACHIEVED. TEST SANITARY DRAINAGE AND VENT SYSTEM BY FILLING WITH WATER, WITH ALL POINTS IN THE SYSTEM BEING SUBJECT TO PRESSURE OF AT LEAST 10' OF WATER. WATER LEVEL SHALL REMAIN STATIONARY FOR A PERIOD OF ONE HOUR, WITHOUT ANY PIPE OR JOINT LEAKAGE. IF TESTING INDICATES DEFICIENT REPLACE OR REPAIR AS REQUIRED, AND REPEAT TEST UNTIL STANDARDS ARE ACHIEVED. EriT. a GENERAL NOTES A. SPECIFICATIONS, REFER TO "PLUMBING" SPECIFICATIONS AND ELSEWHERE IN DRAWINGS FOR FURTHER INFORMATION AND REQUIREMENTS FOR PLUMBING CONTRACTOR. B. SUSPEND ALL HORIZONTAL SERVICE PIPING SHOWN ON THIS PROJECT SUCH AS, BUT NOT LIMITED TO WATER, SANITARY WASTE/VENT, STORM WATER, GAS. ETCETERA FROM UNDERSIDE OF ROOF ANO/OR FLOOR STRUCTURE, UNLESS OTHERWISE NOTED OR INDICATED. HOLD SUCH PIPING HIGH AS POSSIBLE, EXTEND PIPING DOWN IN WALLS, PARTITIONS, CHASES, ETCETERA TO SERVE FIXTURES AND EQUIPMENT AS SHOWN ON PLANS. C. CONTRACTORS AND SUB—CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WiTHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. D. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. PROVIDE PIPE RISES, DROPS. AND OFFSETS, AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. E. DRAWINGS FOR PLUMBING WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE PIPING, CONNECTIONS, FITTINGS, VALVES, OFFSETS, ETCETERA AND ALL MATERIALS NECESSARY FOR A COMPLETE SYSTEM. SUBMIT SHOP DRAWINGS PER THE SPECIFICATIONS. F. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY, INCLUDING APPLICABLE SECTIONS OF ANY INTERIM AMENDMENTS AT THE TIME OF THE PROPOSAL. PURCHASE ALL PERMITS ASSOCIATED WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. G. PROVIDE BACKFLOW PREVENTION DEVICES, (BPD) IN WATER LINES FEEDING PLUMBING FIXTURES AND/OR EQUIPMENT, AS SHOWN ON PLANS AND ELSEWHERE AS REQUIRED BY LOCAL AUTHORITIES. USE DEVICES OF APPROVED TYPE AND MANUFACTURER (ATMOSPHERIC VACUUM, PRESSURE VACUUM, DOUBLE CHECK, AND REDUCED PRESSURE), H. VERIFY SERVICE CONNECTION POINTS, SIZES, ELEVATIONS, AND METERING LOCATIONS FOR PROJECT WITH LOCAL UTILITIES COMPANY'S AND/OR CIVIL ENGINEER. SERVICES TO INCLUDE BUT NOT LIMITED TO DOMESTIC WATER, FIRE, SANITARY SEWER, STORM SEWER, GAS, ETCETERA. I. WATER PRESSURE. PLUMBING CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. IF PRESSURE AT BUILDING ENTRY, PRIOR TO ALL LOCALLY REQUIRED DEVICES SUCH AS WATER METER, BACKFLOW PREVENTION DEVICES, ETCETERA IS LESS THAN 55 PSIG STATIC, CONTACT OWNERS REPRESENTATIVE. IF PRESSURE IS IN EXCESS OF 80 PSIG STATIC. INSTALLATION OF PRESSURE REDUCING VALVE IS REQUIRED. J. WATER HAMMER ARRESTORS SHALL BE INSTALLED THROUGHOUT PLUMBING WATER SYSTEMS AS REQUIRED, SEE "WATER HAMMER ARRESTOR" DETAIL ON THIS SHEET, PLUMBING SYMBOLS LEGEND - COLD WATER (CW) - - HOT WATER (HW) 120' --- PLUMBING VENT (V) LAVATORY SANITARY WASTE (SAN) — BELOW SLAB/GRADE --+4 -- PIPE TURNING UP/DOWN --19 TEE TURNING UP/DOWN 104 SHUTOFFSHUTOFF VALVE (BALL TYPE) --•y�i----vt--- CHECK VALVE ** FIXTURE IDENTIFICATION ** PLAN NOTE AFF/AFG ABOVE FINISHED FLOOR/GRADE VTR VENT THRU ROOF CO CLEANOUT WCO WALL CLEANOUT FFCO/FGCO FLUSH FLOOR/GRADE CLEANOUT PC PLUMBING CONTRACTOR FPC FIRE PROTECTION CONTRACTOR & CONNECT TO EXISTING FIRE PROTECTION DESIGN CRITERIA THIS SPACE IS NOW PRESENTLY PROVIDED WITH AN AUTOMATIC WET PIPE SPRINKLER SYSTEM. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR THE MODIFICATION OF THE ORIGINAL DESIGN, PROVIDE NEW LAYOUT WITH DESIGN UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER, AND ALL MATERIALS REQUIRED FOR A COMPLETE INSTALLATION OF THE PROPOSED TENANT FINISH OF THIS SPACE. CONTRACTOR SHALL PREPARE ALL REQUIRED DRAWINGS, CALCULATIONS AND P.E. SEALS, AND SHALL HAVE APPROVAL OF ALL STATE, LOCAL, & INSURANCE UNDERWRITING AUTHORITIES AS WELL AS MEETING ALL NFPA REQUIREMENTS. THE SPRINKLER SYSTEM SHALL BE TESTED UNDER PRESSURE BY FIRE PROTECTION CONTRACTOR, INSPECTED AND APPROVED BY LOCAL FIRE MARSHALL PRIOR TO ACCEPTANCE BY OWNER. CONSULT WITH LANDLORD REPRESENTATIVE FOR EXACT CONDITIONS OF EXISTING FIRE PROTECTION SYSTEM. LOCATION, CONNECTION POINT, SIZE, TYPE, ETC. PLUMBING PLAN NOTES [D DOMESTIC WATER, CONNECT TO EXISTING DOMESTIC WATER STUB PROVIDED BY LANDLORD IN THIS VICINITY — VERIFY. MAKE NECESSARY CONNECTIONS AS REQUIRED. PROVIDE WATER METER AS REQUIRED BY LANDLORD. �2 SANITARY VENT, CONNECT TO EXISTING SANITARY VENT STUB PROVIDED BY LANDLORD IN THIS VICINITY - VERIFY. MAKE NECESSARY CONNECTIONS AS REQUIRED. M3 SANITARY WASTE, CONNECT TO EXISTING SANITARY WASTE STUB PROVIDED BY LANDLORD IN THIS VICINITY - VERIFY. MAKE NECESSARY CONNECTIONS AS REQUIRED. SAW CUT EXISTING CONCRETE FLOOR SLAB, EXCAVATE, BACKFILL, REPAIR VAPOR BARRIER, AND REPAIR CONCRETE FLOOR SLAB TO MATCH EXISTING AS REQUIRED. ® PROVIDE WATER HEATER IN THIS VICINITY PER "WATER HEATER" DETAIL ON THIS SHEET. PLUMBING FIXTURE SCHEDULE OA TANK WATER CLOSET (HANDICAP): AMERICAN STANDARD #2377.100 "CADET", FLOOR MOUNTED, WHITE VITREOUS CHINA, ELONGATED SIPHON JET BOWL, PRESSURE ASSISTED 1.6 GPF, RIM 17-1/4" AFF WITH TANK COVER LOCKING DEVICE. OLSONITE #95SS OPEN FRONT SEAT LESS COVER. PROVIDE LOOSE KEY ANGLE STOP. © LAVATORY (HANDICAP WALL HUNG): AMERICAN STANDARD #0124.024 "COMRADE", 20"08", WHITE VITREOUS CHINA, BACK OVERFLOW, FAUCET LEDGE, SOAP DEPRESSION AND WALL HANGER. CHICAGO FAUCET #802-317, 4" CENTER SET WITH 4" WRIST BLADES HANDLE. PROVIDE GRID STRAINER DRAIN WITH TAILPIECE, CHROME PLATED CAST BRASS P—TRAP WITH CLEANOUT, WASTE ARM TO WALL WITH ESCUTCHEON, 0.5 GPM AERATOR AND LOOSE KEY ANGLE STOPS. INSULATE WATER AND WASTE PiPING UNDER LAVATORY WITH TRUEBRQ "LAV GUARD2" #102E—Z. RI 34" AFF TO RIM. UC WATER HEATER (INSTANTANEOUS): CHRONOMITE #SR -30L, 120V-10, 3.6 KW, 30 AMPS, 0.5 GPM AT 49'F TEMPERATURE RISE, 25 PSIG MINIMUM WATER PRESSURE REQUIRED WITH CONTROL. CELCON WATERWAYS AND STAINLESS STEEL HEATING COILS. FULL FACTORY WARRANTY ON MATERIAL, PART AND WORKMANSHIP FOR 1 YEAR DATE OF INSTALLATION. © WATER COOLER (HANDICAP): ELKAY #EZS8, MINIMUM CAPACITY 8.0 GPH FROM WF TO 50'F WITH AMBIENT TEMPERATURE OF 917F UTILIZING A 1/5 HP, 115V, SINGLE—PHASE COMPRESSOR. PROVIDE LOOSE KEY ANGLE STOP, P—TRAP WITH CLEANOUT AND WASTE ARM TO WALL. MONT ORIFICE AT 35-3/$" AFF. �E FLOOR DRAIN (LIGHT DUTY): JR SMITH #2010 CAST IRON DRAIN WITH NICKEL BRONZE STRAINER, MEMBRANE FLASHING CLAMP. PROVIDE OUTLET WITH P—TRAP. CLEAN AND POLISH STRAINER TOP FTER INSTALLATION. OPTIONAL ROUND OR SQUARE STRAINER. OF TRAP PRIMER: JR SMITH #2699, AUTOMATIC TRAP PRIMER, 1/2" INLET & OUTLET CONNECTIONS WITH ANTI—SIPHON PORTS. INSTALL TRAP PRIMER IN ACCESSIBLE LOCATION WITH TRAP PRIMER MINIMUM 6" ABOVE FLOOD LEVEL OF FLOOR DRAIN RIM. FIXTURE BRANCH SCHEDULE FIXTURE COLD WATER HOT WATER WASTE VENT LAVATORY 1/2" 1/2" 1-1/2" 1-1/2- -1/2"FLOOR FLOORDRAIN -- -- 2" 11-1/2- -1/2"WATER WATERCOOLER 1/2" -- 1-1 /2" 1-1/2" WATER CLOSET (TANK) 1/2" --- 4" 2" 511-L5 ARE MINIMUM tIKANUM 514t 1U r IX 1 UKt. IINSTALL PER PDI STANDARDS AND PDI I I MANUFACTURER'S SIZE INSTRUCTIONS A SINGLE FIXTURE PDI SIZE PIPE SIZE FIXTURE UNIT LOAD A All 1-11 B -Y4" 12-32 C 1 " 33-60 r-- HOT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE WHA AT END OF LINE. IF BRANCH IS GREATER THAN 20' LONG, PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS —, FIXTURE UNIT TABULATION FIXTURE COLD HOT WATER CLOSET 2.5 -- LAVATORY .75 .75 WATER COOLER 0.5 -- PC TO PROVIDE WATER HAMMER ARRESTORS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O—RING CONSTRUCTION, HAVING PDI #WH -201, ASSE #1010 AND ANSI #A1 12.26.1 M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND/OR PER THE TABLES SHOWN ABOVE. 0WATER HAMMER ARRESTOR 5 - NOT TO SCALE 01 PLUMBING PLAN se WASTE AND VENT PLUMBING PLAN se WATER 1/4' - 1'-0" 021/4" - 1'-0" 2,r I 1100' 1 2" / WCO 2"2" Y4"., 4 y2" 1%" 4" N B I Ya a 10 " 4 1„ X2" ©„ err � TO FD 410 Jli„ v 4" OWASTE AND VENT RISER 3NOT TO SCALE -Y4" COLD WATER DOWN IN C LAVATORY V' HOT WATER TO FAUCET — INSTANTANEOUS TYPE WATER HEATER MOUNTED ON WALL BELOW LAVATORY 1V VENT UP IN WALL Y" COLD WATER 1 TO FAUCET 1 STOP AND WASTE VALVE O I 11-,--2" WASTE PIPE PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. 06WATER HEATER NOT TO SCALE 0WATER RISER 4NOT TO SCALE L.L. NO EXCEPTIONS TAKEN 6/9/2006 IO Larson Binkley, Inc. 6363 College Blvd., Suite 400 Overland Park, Kansas 66211 Florida Certificate of Authorization Number 8039 T 913-383-2621 F 913-383-2831 lorsonbinkley.com COPYRIGHT 2006 Christopher R. Larson, PE0043082 c /00/� John C. Coulter, PE0030426 2'246 `i�$I�}HT NOTICE: These drawings and specifications are copyrlghted and sub)eat to copyR ht protection as an-arahit�otulrol work' under sec. 10 of the capirNght act, 11 u.3.C. As amended december 1990. The protection Includes, without limitation. the overall form, arrangement and composition of apace. and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. L Go V 4W 1" V VLee T-. 4) 4 _ = Q a) oo N O V O M i- di W J ■ un 4) C O 111111 o �zV ° a 111=1 0 o E Ca m _ 0 N to � n BITE: b/OI /Ob SHEET: ORAWN W. P 1 L8s*. RUEGT Na.: CMM"024 (C "I CID) (i kV - PANEL TRANSFORM DISCONNECT FOR ALL SLAB PENETRATIONS: THE METHOD, DEPTHS, AND LOCATIONS SHALL BE PRE -APPROVED BY MALL FIELD Q REP. PRIOR TO WORK START. i CONDUIT IN LANDLORD WALLS: 4 -ROMEX CABLE IS SPECIFICALLY PROHIBITED. -FLEXIBLE CONDUIT IS NOT PERMITTED IN DEMISING WALLS. �' V CASHWRAP POWER DETAIL KEY NOTES O LOCATION OF DOOR BUZZER PUSHBUTTON, ROUTE LOW VOLTAGE WIRING TO BUZZER IN STOCKROOM, VERIFY EXACT LOCATION WITH OWNER. O SWITCH FOR CASE LIGHTING, VERIFY LOCATION WITH OWNER. PROVIDE A COMBINATION COVERPLATE FOR THE CASE LIGHTING SWITCH AND THE ADJACENT I.G. RECEPTACLE. �3 SWITCHED JUNCTION BOX FOR CASE LIGHTING ® FIELD INSTALLED RECEPTACLES. O FIELD INSTALLED DATA/PHONE OUTLETS, ©PROVIDE FLUSH MOUNTED CAST JUNCTION BOXES AT CONDUIT STUB—UP LOCATIONS FOR POWER AND COMMUNICATION CABLING, REFER TO FLOOR PLANS FOR MORE INFORMATION. VERIFY EXACT STUB -UP LOCATION WITH ARCHITECTURAL PLANS PRIOR TO SAW CUTTING (OR CORE DRILLING) 0 ROUTE CIRCUITS THROUGH CONDUITS DESCRIBED IN NOTE #6 ABOVE TO ABOVE CEILING AS SHOWN ON FLOOR PLANS. (MINIMUM 3/4" CONDUIT) ®ELECTRIC BUZZER MOUNTED 13'-0" AFF. ROUTE 120V POWER TO BUZZER TRANSFORMER, AND LOW VOLTAGE WIRING BETWEEN BUZZER AND PUSH BUTTON AT REAR ENTRANCE. DO NOT ROUTE 120V AND LOW VOLTAGE CABLING IN COMMON CONDUIT. g� 3/4" CONDUIT — 'DIRTY" POWER 3/4" CONDUIT — "CLEAN" POWER 3/4" CONDUIT -- TELEPHONE 3/4" CONDUIT - BELL/BUZZER \u/ OCASHWRAP POWER DETAIL 2NOTTO SCALE POWER PLAN KEY NOTES �1 REFER TO CASHWRAP DETAIL, THIS SHEET FOR MORE INFORMATION. ROUTE CONDUITS UNDER SLAB FOR STUB -UP UNDER TRAP DOORS IN CASHWRAP. VERIFY APPROVED METHOD OF SLAB PENATRATION (CORE DRILLING, SAW CUTTING, ETC.) WITH MALL'S CONSTRUCTION MANAGER PRIOR TO COMMENCING WORK. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING FLOOR AFTER WORK IS COMPLETE. ROUTE ALL THE CONDUITS IN A COMMON TRENCH. �3 POWER CONDUITS SHALL RUN CONTINUOUS BACK TO PANELBOARD. TELEPHONE/DATA CONDUIT SHALL BE ROUTED BACK TO MAIN TELEPHONE BOARD. BUZZER CONDUIT SHALL BE ROUTED TO ABOVE ACCESSIBLE CEILING. REFER TO CASHWRAP DETAIL, THIS SHEET FOR PANEL AND CIRCUIT NUMBERS. M4 PROVIDE JUNCTION BOX AND (1) 3" CONDUIT WITH END BUSHING UP WALL TO 14'-0" AFF FOR CAMERA WIRING. 0 NOT USED. ® NOT USED. M7 SAWCUT (OR CORE DRILL) EXISTING SLAB AND ROUTE (1) 3/4" CONDUIT FROM SENSORMATIC PAD LOCATION AND STUB OUT AT SOFFIT IF POSSIBLE OR AT 14'-0" AFF NEAR RECEPTACLE MOUNTED ON SIDE WALL PER NOTE #8. ® MOUNT RECEPTACLE IN SOFFIT IF POSSIBLE OR AT 14'-0" AFF FOR SENSORMATIC ANTI -THEFT SYSTEM POWER. MOUNT SPEAKER PER ARCHITECTURAL ELEVATIONS. ag MOUNT RECEPTACLE IN SOFFIT, VERIFY LOCATION WITH ARCHITECTURAL ELEVATIONS. 10 PROVIDE JUNCTION BOX FOR STORE SIGN, VERIFY EXACT LOCATION WITH SIGN SUPPLIER PRIOR TO ROUGH -IN. CIRCUIT SHALL RUN THROUGH 7 -DAY TIME CLOCK. 11 PROVIDE JUNCTION BOX FOR ELECTRIC BUZZER AT 13'-6" AFF. ROUTE 120V POWER TO BUZZER TRANSFORMER, AND LOW VOLTAGE WIRING BETWEEN BUZZER AND PUSH BUTTON AT CASHWRAP. 12 TELEPHONE JACK AT +18" AFF AT STOCK ROOM DESK. RUN 3/4" CONDUIT TO T.T.B. WITH PULL STRING. 13 TELEPHONE JACK AT +18" AFF FOR COMPUTER SYSTEM CONNECTION AT STOCK ROOM DESK. RUN 3/4" CONDUIT TO T.T.B. WITH PULL WIRE. 14 ISOLATED DUPLEX OUTLET, (HUBBELL OR EQUAL) WITH DEDICATED GROUND MOUNTED IN WALL AT +18" AFF AT STOCK ROOM DESK AND D.M. OFFICE FOR VIDEO SURVEILENCE. S QUADPLEX RECEPTACLE AT STOCKROOM/ D.M. OFFICE DESK 1 g PROVIDE JUNCTION BOX IN WALL NEXT TO NOTE 17 WITH 3/4" CONDUIT BETWEEN FOR STEREO VOLUME CONTROL. 17 PROVIDE JUNCTION BOX AT 88" AFF FOR AUDIO SYSTEM WITH 1/2" EMT CONDUIT WITH PULL STRING TO BOSE BASE UNIT. VERIFY ALL STEREO CONDUIT LOCATIONS WITH BOSE CORP. AND ARCHITECT. 18 PROVIDE RECEPTACLE ON DEDICATED CIRCUIT, AT 88" AFF FOR CD PLAYER AND BASS MODULE. 19 DOOR BUZZER PUSHBUTTON LOCATED AT REAR DOOR, ROUTE LOW VOLTAGE WIRING TO BUZZER AT CASHWRAP, VERIFY EXACT LOCATION WITH OWNER. ® PROVIDE 2'X4'X3/4" PLYWOOD FOR TELEPHONE EQUIPMENT. LANDLORD TO PROVIDE 1" CONDUIT TO TELEPHONE COMPANYS TENANT SERVICE ROOM. 21 PROVIDE QUADPLEX RECEPTACLE AT 84" AFF FOR TELEPHONE AND SECURITY EQUIPMENT. © TIMECLOCK AND CONTACTOR LOCATIONS. ©PROVIDE JUNCTION BOX AT 48" AFF WITH 3/4" CONDUIT TO ABOVE ACCESSIBLE CEILING FOR THERMOSTAT AND REMOTE TEMPERATURE SENSOR, PROVIDED BY OTHERS. ® NOT USED. ® DISCONNECT SWITCH PROVIDED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO PROVIDE 2—#12 & 1—#12 GND. IN 1/2"C. PROVIDE JUNCTION BOX AND 30A TOGGLE SWITCH FOR WATER HEATER. VERIFY MOUNTING HEIGHT WITH PLUMBING CONTRACTOR. ® ISOLATED DUPLEX OUTLET. (HUBBELL OR EQUAL) WITH DEDICATED ITrT GROUND .IAI,\h I►1 WA. 1 ♦. tom" Arr V rnd nwk,row COTr►1 I GENERAL ELECTRICAL NOTES I 1. ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFICATION OF DOOR BUZZER MANUFACTURER AND PART NUMBERS. 2. THE WORD 'PROVIDE" HEREIN SHALL MEAN TO FURNISH AND INSTALL. L.L. APPROVED AS NOTED 6/9/2006 0MANAGER'S DESK DETAIL 3NOT TO SCALE 2246 COPYRIONT NOTICE - These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under *so. 102 of the copyright act. 17 u.S.C. As december amended 1990. The protection Includes. without IlmNation. the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result In oeteallon of construction, building seizure, and/or monetary liability. � L U V LE �- C C o V F- a LUj ■ o� LL 0�Zv ■C 0 �•- 4� No O E m c ao MM Vf !V 4A Vf LL as cc W 3 0 a 8 1 71 DAM:: 6/01/06 SHEET SCALE 1/4"=1 I -oil DRAWN 6Y: E 1 NW=W: LJW MMO6024 120 VOLT CONTROL CIRCUIT "L-18" r ' — ' 71— INTERMATIC #T7401 B. 4PST, 120V. TC I r . _.....� C1 PANEL TRANSFORM DISCONNECT 0 1 LIUM I Ince rLAN 1/4"- 1'-0" J LIOHTINO PLAN KEY NOTES 2 -GANG JUNCTION BOX IN CEILING FOR RCA AND SPEAKER WIRE. PROVIDE 1/2" EMT CONDUIT WITH PULL STRING TO EACH SPEAKER LOCATION. VERIFY EXACT LOCATION WITH BOSE CORP DRAWINGS. DUPLEX OUTLET MOUNTED ON UNI -STRUT FOR CAMERA MONITOR. PROVIDE 1/2' EMT CONDUIT WITH PULL STRING TO DIGITAL VIDEO RECORDER AT MANAGER'S DESK. �3 DUPLEX OUTLET MOUNTED ON UNI -STRUT FOR SIGN. ® REFER TO LIGHTING CONTROL DIAGRAM, THIS SHEET FOR MORE INFORMATION. HOME RUN THROUGH LIGHTING CONTACTOR. WIRING FOR EMERGENCY AND EXIT LIGHTS TO BE AHEAD OF ANY CONTACTOR CONTROL. © PROVIDE 4"X4" JUNCTION BOX WITH METAL COVER PLATE WITH 1/2" KNOCKOUT AT 12'-0" AFF AS PER CAMERA LAYOUT DRAWING AND NOTES FOR CAMERA MOUNTING. CABLING AND CAMERA INSTALLATION BY OTHERS. r7 PROVIDE SEPERATE 1/2" CONDUIT RUN WITH PULL STRING FOR EACH VIDEO JUNCTION BOX NEAR RECESSED 3" CONDUIT BEHIND MANAGER'S DESK AT 14'-0" AFF DESCRIBED IN NOTE #4 SHEET E1. ® CAMERA MUST BE LOCATED 3'-0" FROM FROM DEMISING WALL. IU 2 Limp 1 inn rLAR 1/4"=l' -O" L,—.J SWITCH 'BPI' PROVIDE BYPASS TIMED SWITCH WITH MAXIMUM SETTING OF 2 HOURS. LOCATE ABOVE SWITCHES AS SHOWN ON PLANS. V GENERAL SALES LIGHTS .— �---� F --I-- SPARE —�--� �--- j--- SPARE it SPARE L-21-------�--- FITTING ROOM LIGHTS L-23 UNI—STRUT LIGHTS L-25 UNI -STRUT LIGHTS L-29�. UNI -STRUT LIGHTS --�—i �--r--- UNI -STRUT LIGHTS --.I- 1----1-- UNI -STRUT LIGHTS —�---I I---�--- SPARE L t i -SPARE L-26 F--1-- UNI -STRUT LIGHTS L-30UNI-STRUT LIGHTS L --32 ------t--- UNI -STRUT LIGHTS L-42 i UNI -STRUT LIGHTS --�--{ I----- SPARE --�—i (---- SPARE —I---) �--I-- SPARE SPARE 0 3 LIGHTING CONTROL DIAGRAM NOT TO SCALE NOTES: 1. ALL CONTACTOR SHALL BE 20A ELECTRICALLY HELD WITH NUMBER OF POLES SHOWN. 2. INSTALL CONTACTORS IN NEMA 1 ENCLOSURE WITH HINGED COVER, LIGHT FIXTURE SCHEDULE SYMBOL DESCRIPTION I I L-10STORE SIGN CATALOG NUMBER L-16 f- -- UNI -STRUT SIGN VOLTAGE I I L-18 LIGHTS - STORE FRONT MOUNTINGS REMARKS I i L -20 —I -----j-- LIGHTS - STORE FRONT DRAWN 0Y: SPARE --I I--- SPARE E2 U LJW PANEL TRANSFORM DISCONNECT 0 1 LIUM I Ince rLAN 1/4"- 1'-0" J LIOHTINO PLAN KEY NOTES 2 -GANG JUNCTION BOX IN CEILING FOR RCA AND SPEAKER WIRE. PROVIDE 1/2" EMT CONDUIT WITH PULL STRING TO EACH SPEAKER LOCATION. VERIFY EXACT LOCATION WITH BOSE CORP DRAWINGS. DUPLEX OUTLET MOUNTED ON UNI -STRUT FOR CAMERA MONITOR. PROVIDE 1/2' EMT CONDUIT WITH PULL STRING TO DIGITAL VIDEO RECORDER AT MANAGER'S DESK. �3 DUPLEX OUTLET MOUNTED ON UNI -STRUT FOR SIGN. ® REFER TO LIGHTING CONTROL DIAGRAM, THIS SHEET FOR MORE INFORMATION. HOME RUN THROUGH LIGHTING CONTACTOR. WIRING FOR EMERGENCY AND EXIT LIGHTS TO BE AHEAD OF ANY CONTACTOR CONTROL. © PROVIDE 4"X4" JUNCTION BOX WITH METAL COVER PLATE WITH 1/2" KNOCKOUT AT 12'-0" AFF AS PER CAMERA LAYOUT DRAWING AND NOTES FOR CAMERA MOUNTING. CABLING AND CAMERA INSTALLATION BY OTHERS. r7 PROVIDE SEPERATE 1/2" CONDUIT RUN WITH PULL STRING FOR EACH VIDEO JUNCTION BOX NEAR RECESSED 3" CONDUIT BEHIND MANAGER'S DESK AT 14'-0" AFF DESCRIBED IN NOTE #4 SHEET E1. ® CAMERA MUST BE LOCATED 3'-0" FROM FROM DEMISING WALL. IU 2 Limp 1 inn rLAR 1/4"=l' -O" L,—.J SWITCH 'BPI' PROVIDE BYPASS TIMED SWITCH WITH MAXIMUM SETTING OF 2 HOURS. LOCATE ABOVE SWITCHES AS SHOWN ON PLANS. V GENERAL SALES LIGHTS .— �---� F --I-- SPARE —�--� �--- j--- SPARE it SPARE L-21-------�--- FITTING ROOM LIGHTS L-23 UNI—STRUT LIGHTS L-25 UNI -STRUT LIGHTS L-29�. UNI -STRUT LIGHTS --�—i �--r--- UNI -STRUT LIGHTS --.I- 1----1-- UNI -STRUT LIGHTS —�---I I---�--- SPARE L t i -SPARE L-26 F--1-- UNI -STRUT LIGHTS L-30UNI-STRUT LIGHTS L --32 ------t--- UNI -STRUT LIGHTS L-42 i UNI -STRUT LIGHTS --�--{ I----- SPARE --�—i (---- SPARE —I---) �--I-- SPARE SPARE 0 3 LIGHTING CONTROL DIAGRAM NOT TO SCALE NOTES: 1. ALL CONTACTOR SHALL BE 20A ELECTRICALLY HELD WITH NUMBER OF POLES SHOWN. 2. INSTALL CONTACTORS IN NEMA 1 ENCLOSURE WITH HINGED COVER, LIGHT FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURER CATALOG NUMBER LAMP VOLTAGE WATTS MOUNTINGS REMARKS TAG DRAWN 0Y: E2 U LJW PwO Kr Nm: A SURFACE MOUNTED FIXTURE HE WILLIAMS #SU4-22-240TT-33S (2) 40W�ONG TWIN 120 96 SURFACE (2) Go BE 0 V W C DECORATNE PENDENT TALLER UNO PENDULO P.164470 (1)15W A-19 120 15 PENDENT LLI o�:zv TBX39E SL W1 CLEAR C �° �0 D FLUORESCENT MONO POINT JUNO LOUVER AND #SP2197BL (2) FM DL/825 120 78 UNI -STRUT CL m TRACK HEAD E WALL SCONCE TALLER UNO MITO FOCO 152120 (1)15W A-19 120 15 SURFACE (1), (5) G DOWNLIGHT JUNO (1) 60W PAR38 FL 120 60 RECESSED H DOWNLIGHT JUNO (1) BOW PAR38 FL 120 60 RECESSED J LOW VOLTAGE TRACK HEAD JUNO TLP116SL DELTA 200 (1) 5OW MR16 120 55 TRACK JT JUNO 12V TRANSFORMER JUNO TFS300BL N/A 120V112V 300 ABOVE CEILING K 4 FLUORESCENT STRIP LITHONIA C132 -120 -ES (1) F32TB CW/SS 120 32 CHAIN M INCANDESCENT MONO POINT JUNO #T4378L-3P2900SL (1) 60W PAR 38 120 60 UNI -STRUT X1 EXIT SIGN WITH BATTERY PACK EMERGI-LRE EMG-LXNIRC-U INCLUDED WITH 120/277 10 UNI -STRUT (2), (3) FIXTURE )a EXIT SIGN WITH BATTERY PACK EMERGI-LITE EMG-LXNIRC-U INCLUDED WITH 1201277 10 WALL MOUNT (2),(6) FIXTURE X3 EXIT SIGN WITH BATTERY PACK EMERGI-LITE EMG-ECLXN4R INCLUDED WITH 1201277 10 WALL MOUNT (2),(4),(6) FIXTURE Y EMERGENCY FIXTURE WITH BATTERY EMERGI-LITE EMG-ECX2 (HD) INCLUDED WITH 1201277 10 UNIVERSAL (2) PACK FIXTURE GENERAL SCHEDULE NOTES: A. INSTALLATION OF FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENT'S. B. ALL LIGHT FIXTURES SHALL BE SUPPLIED BY CONTRACTOR UNLESS NOTED OTHERWISE. REMARKS: 1 WITH POLISHED ALUMINUM BODY AND WHITE CRYSTAL SHADE. 2 PROVIDE WITH BATTERY PACK WITH BACK-UP 90 MUNUTES MINMUM. 3 MOUNT 1Z -U' AFF ON UNI -STRUT WITH JUNCTION BOX 4 INSTALL IN NON -SALES AREA ONLY. 5 VERIFY MOUNTING HEIGHTS WITH ARCHITECT. 6 MOUNT FIXTURE ON WALL CENTERED ABOVE THE DOOR. 7 PROVIDE TWO -LAMP BALLASTAS REQUIRED AND TANDUM WIRE SINGLE LAMP FIXTURES. GENERAL ELECTRICAL NOTES 1. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF LIGHT FIXTURES. 2. ALL WIRING IN CONCEALED WALLS SHALL BE 'MC' TYPE WITH GROUND, UNLESS 'MC' CABLING IS NOT ALLOWED THEN EMT CONDUIT SHALL BE USED. 3. ALL WIRING IN OPEN CEILINGS AND WALLS SHALL BE IN EMT CONDUIT AND FLEXILE METALIC CONDUIT SHALL BE USED ONLY FOR FINAL CONNECTIONS TO EQUIPMENT AND NOT TO EXCEED 6' IN LENGTH. 4. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. I i A/11 =Yr`=01r1nA/C Td V=A/ 4/0/7tfMA 2246 COPYRIGHT NOTICES These drawings and specifications are copyrighted and subject to co ht protection as an "arahtteatural work" under sea. 102 of Mcopyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and compoetiion of spacer, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result In a of construction, bullding setsure, and/or monetary Itabllity. L SHEET: 6/0I/06 V.XE: L 400 DRAWN 0Y: E2 U LJW PwO Kr Nm: 02M016024 GoTees C 4 C Go 0 V W FM (9 IJ 4o ■ O LLI o�:zv C �° �0 c 00 CL m H J U6 f. aon 2 L6 r. TATE. SHEET: 6/0I/06 V.XE: 1/411=11-011 DRAWN 0Y: E2 LJW PwO Kr Nm: 02M016024 GENERAL ELECTRICAL SPECIFICATIONS THE WORK INCLUDES PROVIDING NEW MATERIALS, FIXTURES, DEVICES AND ACCESSORIES NECESSARY FOR A COMPLETE FUNCTIONING ELECTRICAL SYSTEM. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES OR ORDINANCES AND SUBJECT TO INSPECTION. COMPLY WITH ALL LAWS APPLYING TO ELECTRICAL INSTALLATIONS IN EFFECT, AND WITH THE MOST RECENT EDITION OF THE NEC, ADA, APPLICABLE SECTIONS OF OTHER NEPA, OSHA, LIFE SAFETY CODES AND RECOMMENDATIONS, AND THE INTERIM AMENDMENTS IN EFFECT AT THE TIME OF THE PROPOSAL. ALL MATERIALS USED SHALL BE NEW AND SHALL CONFORM TO THE STANDARDS ESTABLISHED BY THE UNDERWRITERS LABORATORIES INCORPORATED. THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK REQUIRED FOR THE PROJECT, THE DRAWINGS FOR ELECTRICAL WORK ARE DIAGRAMMATIC, SHOWING THE LOCATION, TYPE, DEVICES AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. PROVIDE ALL FIXTURES, DEVICES, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM'S FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT FURNISHED BY OTHERS. TEMPORARY SERVICES: ARRANGE FOR SOURCES OF TEMPORARY CONSTRUCTION SERVICES. SUCH SERVICES SHALL BE NOMINALLY 120/240 VOLT, SINGLE—PHASE, THREE—WIRE FROM WHICH A COMPLETE SYSTEM OF TEMPORARY POWER AND LIGHTING CAN BE PROVIDED FOR ALL CONSTRUCTION NEEDS. ELECTRICAL DESIGN FOR THIS INSTALLATION IS BASED ON FIELD INSPECTIONS AND PREVIOUS DESIGN DRAWINGS FOR THE EXISTING BUILDING. ELECTRICAL CONTRACTOR IS TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. ALLOWANCES ARE TO BE INCLUDED FOR UNFORESEEN EXISTING CONDITIONS THAT MAY EFFECT THE CONTRACTOR'S SCOPE OF WORK. MINOR DEVIATIONS REQUIRED FOR ACCOMPLISHING THE INTENT OF THIS DESIGN IS TO BE INCLUDED IN THIS ALLOWANCE. ROOF PENETRATIONS SHALL COMPLY WITH "SMACNA" AND "NRCA" STANDARDS, AND WITH THE REQUIREMENTS OF THE EXISTING ROOFING WARRANTY, IF APPLICABLE. DO NOT PERFORM ROOFING PENETRATIONS IN A MANNER WHICH WOULD VOID OR OTHERWISE LIMIT THE EXISTING ROOFING WARRANTY. ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING EQUIPMENT AS SHOWN ON DESIGN DRAWINGS AND ARE IN GOOD WORKING CONDITION PRIOR TO RE—USING, IF EXISTING CONDITIONS ARE NOT AS SHOWN OR ARE NOT IN GOOD WORKING CONDITION, CONTRACTOR SHALL PROVIDE EQUIPMENT, CONDUIT, AND/OR WIRE AS INDICATED TO PROVIDE A "LIKE—NEW" AND CODE COMPLIANT INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR RELOCATING ANY EXISTING ITEMS BEING REUSED. ANY EXISTING EQUIPMENT, CONDUIT OR WIRE NOT BEING REUSED SHALL BE REMOVED BY THIS CONTRACTOR. ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF 75'C CONDUCTORS CONNECTED TO TERMINAL LUGS AND EQUIPMENT, U.L. LISTED FOR A MINIMUM 75C. CONDUCTORS TERMINATED ON EQUIPMENT OR DEVICES WITH A LOWER RATING (6(rC) OR NO RATING SHOWN, SHALL HAVE CONDUCTOR SIZE INCREASED TO CONFORM TO NEC TABLE 310-16 AND U.L. NO. 489 REQUIREMENTS. DISCONNECT SWITCHES SHALL BE HEAVY—DUTY, QUICK—MAKE, QUICK—BREAK TYPE, NEMA 1 ENCLOSURE FOR INDOOR LOCATIONS (NEMA 3R FOR OUTDOOR LOCATIONS). SWITCHES SHALL BE AS MANUFACTURED BY SQUARE V. GENERAL ELECTRIC, OR SIEMEN'S (I.T.E.). PROVIDE FUSES AS MANUFACTURED BY BUSSMAN, GOULD-SHAWMUT, OR LITTLE -FUSE. ALL CONDUCTOR TERMINALS TO BE U.L. LISTED FOR A MINIMUM OF 75'C. SWITCHES USED AS SERVICE ENTRANCE EQUIPMENT TO BE U.L. LISTED AS "SER" RATED EQUIPMENT. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SEIMENS OR EATON CORP. MEETING U.L. STANDARDS 50 AND 67, WITH U.L. LABEL. BREAKERS: THERMAL MAGNETIC TYPE, QUICK—MAKE, QUICK—BREAK, BOLT—IN TYPE OF SINGLE UNIT CONSTRUCTION. TWO AND THREE POLE BREAKERS SHALL BE SINGLE UNIT COMMON TRIP TYPE. ALL BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT SHALL BE "HACR" RATED BREAKERS. CABINETS SHALL BE ONE PIECE CODE GAGE GALVANIZED STEEL WITH MOUNTING STUDS, WIRING GUTTERS OF AMPLE SIZE AND KNOCKOUT FOR CONDUIT CONNECTIONS AS REQUIRED. BUS BARS SHALL BE 98% CONDUCTIVE COPPER, ALUMINUM, OR COPPER—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—SCREW TYPE. PROVIDE GALVANIZED RIGID STEEL (GRS) OR INTERMEDIATE METAL CONDUIT (IMC) OUTDOORS AND IN DAMP LOCATIONS USING THREADED COUPLINGS & CONNECTORS. CLAMP CONDUIT TO BOXES WITH BUSHING INSIDE AND LOCKNUT OUTSIDE. SLAB PENETRATIONS REQUIREMENT& 1. NO PENETRATION OR SAW CUTTING SHALL BE MADE THROUGH SUSPENDED SLAB, WITHOUT MANAGEMENT APPROVAL AND NOTIFICATION OF DATE AND TIME. X—RAYS OF THE AREA OF THE PROPOSED FLOOR OPENING MUST BE TAKEN BEFORE CENTER MANAGEMENT APPROVAL. A QUALIFIED X—RAY CONTRACTOR HIRED AT THE GENERAL CONTRACTOR'S EXPENSE SHALL PERFORM ALL X—RAYS. 2. CENTER MANAGEMENT OFFICE APPROVAL SHALL NOT RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR DAMAGE TO MALL PROPERTY AND/OR ANY TENANT'S PROPERTY DUE TO PENETRATION OR SAW CUTTING OF THE FLOOR SLAB. CONTRACTOR SHALL COORDINATE WITH THE CENTER MANAGEMENT OFFICE WHEN ANY CORE BORING OR SAW CUTTING OF THE FLOOR SLAB IS ATTEMPTED. I3. ALL PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH THE APPROPRIATE FIRE RATED PRODUCTS AND FILLED WITH CONCRETE FILL. ALL CONDUIT AND RACEWAY SYSTEMS TO BE INSTALLED WITH SEPARATE GROUND CONDUCTOR. CONDUIT SYSTEM IS NOT TO BE USED AS THE SOLE GROUNDING MEANS. ALL SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, CONTACTORS, AND TRANSFORMERS SHALL BE PROVIDED WITH LUGS LABELED AND RATED FOR A MINIMUM 75' C. SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, CONTACTORS, AND TRANSFORMERS ARE TO BE "LISTED" AND "IDENTIFIED" AS RATED FOR A MINIMUM OF 75' C CONDUCTOR TERMINATION. CONDUCTORS: INSULATED SOFT ANNEALED 9896 PARE COPPER WITH COLOR CODING, B AND S GAGE, #10 AND SMALLER TO BE SOLID, #8 AND LARGER TO BE STRANDED, MINIMUM #12 UNLESS OTHERWISE INDICATED. ALUMINUM CONDUCTOR WILL NOT BE ALLOWED. THHN MAY NOT BE USED UNDERGROUND, AT SERVICE ENTRANCE, OUTSIDE, OR IN WET LOCATIONS, ALL INSULATION TO BE RATED FOR 600 V AND TYPES AS FOLLOWS: #10 AND SMALLER: THWN OR THHN #8 TO #4/0: THWN OR THHN SERVICE ENTRANCE: USE—RHW OVER #4/0 WET OR HOT SERVICE: XHHW OVER #4/0 ORDINARY SERVICE: THHN OR XHHN WIRE THRU FLUORESCENT FIXTURES : THHN DEVICES SHALL BE MANUFACTURED BY LEVITON "INDUSTRIAL SPECIFICATION GRADE" OR EQUAL. ALL DEVICES AND COVER PLATES SHALL BE IVORY COLOR. STANDARD DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, 20A, NEMA WD -2 STANDARD 5-20R, SIDE WIRED, LEVITON #5342. LIGHT SWITCHES SHALL BE 20 AMP, 120 VOLT, LEVITON #1221-2. WHERE SWITCHES ARE GROUPED, PROVIDE GANG PLATES. LIGHT FIXTURES AND LAMPS ARE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR ACCORDING TO U.B.C. STANDARDS, SECTION 25-2, 1994 EDITION, THE ELECTRICAL CONTRACTOR SHALL REVIEW MATERIALS AT THE TIME OF DELIVERY AND IMMEDIATELY REPORT ANY DAMAGE OR MISSING PIECES. EMERGENCY LIGHTING SHALL HAVE A MINIMUM OF 90 MIN. BATTERY BACK—UP, OR AS REQUIRED BY LOCAL CODE AUTHORITY. LAYOUT BRANCH CIRCUIT WIRING AND ARRANGEMENT OF HOME RUNS FOR MAXIMUM ECONOMY AND EFFICIENCY. INCREASE WIRE SIZE IF VOLTAGE DROP EXCEEDS 3% OR 100 FEET OF LENGTH. CONCEAL WIRING SYSTEM ABOVE SUSPENDED CEILINGS OR IN WALL OR FLOOR CONSTRUCTION WHERE POSSIBLE. INSTALL CONDUITS PARALLEL TO BUILDING LINES, AND TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, STRUCTURE, ETC. INSTALL CONDUIT CONTINUOUS BETWEEN BOXES AND CABINETS WITH NO MORE THAN FOUR (4) 90 DEGREE BENDS. SECURELY FASTEN IN PLACE WITH STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. DO NOT SUPPORT CONDUIT FROM SUSPENDED CEILING GRID OR SUSPENSION WIRES. REAM CONDUIT ENDS BEFORE INSTALLATION AND THOROUGHLY CLEAN BEFORE INSTALLATION. OPENINGS SHALL BE PLUGGED OR COVERED TO KEEP CONDUIT CLEAN. TERMINALS ON SWITCHES AND OUTLET SHALL NOT BE USED TO "FEED THRU" TO THE NEXT SWITCH OR OUTLET. ADJUSTING AND TESTING: ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED AND TESTED FOR PROPER OPERATION. COMPLETED WIRING SYSTEM SHALL BE FREE FROM SHORT CIRCUITS. TOUCH—UP OR REFINISH DAMAGED SURFACES OF FIXTURES AND EQUIPMENT, EXPOSED TO VIEW. TELEPHONE CABLE TO BE FURNISHED AND INSTALLED BY OTHERS. ALL CABLING TO BE PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE NEW PLYWOOD BACKBOARD FOR NEW TELEPHONE TERMINAL BOARD. COORDINATE EXACT REQUIREMENTS WITH LOCAL TELEPHONE UTILITY REPRESENTATIVE AND OWNER. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CUTTING EXISTING CONCRETE FLOOR SLAB. GENERAL CONTRACTOR TO PATCH FLOOR TO MATCH EXISTING. FOR EQUIPMENT FURNISHED BY OWNER OR OTHER CONTRACTORS: ELECTRICAL CONTRACTOR TO VERIFY EXACT LOAD, TYPE OF CONNECTION AND MOUNTING HEIGHT FOR EACH BOX OR EQUIPMENT ITEM TO BE INSTALLED. ALL HARD—WIRED CONNECTIONS TO EQUIPMENT TO BE MADE WITH FLEXIBLE LIQUID—TITE METAL CONDUIT WITH GREEN GROUND CONDUCTOR INSTALLED INSIDE RACEWAY. GROUND CONDUCTOR TO BE BONDED AT BOTH ENDS. PROVIDE DRY—TYPE TRANSFORMER WHICH SHALL BE ENCLOSED AND VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS AND WITH (150) DEGREE CLASS 'H' INSULATION AND MINIMUM OF SIX 2-1/2% TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. TRANSFORMER SHALL COMPLY WITH N.E.M.A. STANDARD "TP -1" FOR OPTIMUM EFFICIENCY AT 359 LOAD. CONTACTORS SHALL BE SQUARE 'D'. CLASS 8903, AS SHOWN ON THE PLANS, ELECTRICALLY HELD, DESIGNED FOR TWO—WIRE CONTROL CIRCUIT, FULLY RATED FOR ALL CLASSES OF INDUCTIVE AND NON—INDUCTIVE LOADS, AND RATED FOR CONTINUOUS CAPACITY AND POWER CIRCUIT VOLTAGE NOT LESS THAN INDICATED ON DRAWINGS. PROVIDE WITH NUMBER OF POLES INDICATED OR SPECIFIED. CONTACTORS SHALL BE FURNISHED WITH NEMA 1. SURFACE MOUNTED ENCLOSURES UNLESS CALLED FOR OTHERWISE ON DRAWINGS. EACH CONTACTOR SHALL BE PROVIDED WITH ENGRAVED LAMINATED PLASTIC NAMEPLATE WITH BLACK BACKGROUND AND 1/4- WHITE LETTERS TO DESIGNATE USE OF CONTRACTOR. DOOR CHIME SYSTEM SHALL INCLUDE ALL WIRING, PUSHBUTTON AND 120/24V TRANSFORMER. VERIFY TONE REQUIRED WITH OWNER PRIOR TO INSTALLATION OF SYSTEM. TRANSFORMER IS TO BE LOCATED IN ACCESSIBLE CEILING SPACE. MALL ELECTRICAL REQUIREMENTS. 1. ALL ELECTRICIANS SHALL BE PRE—APPROVED BY LANDLORD PRiOR TO WORK ON LANDLORD'S SWITCHGEAR. ALL WORK SHALL BE PERFORMED DURING OFF—HOURS, AND NO ONE SHALL BE PERMITTED TO WORK ON SWITCHGEAR WHILE ENERGIZED. 2. ALL ELECTRICAL CONTRACTORS SHALL GO THROUGH CENTER MANAGEMENT OFFICE AND/QR THE OPERATIONS DIRECTOR FOR ACCESS INTO ELECTRICAL ROOMS, AND WILL BE RESPONSIBLE FOR REPLACING ALL PANEL COVERS AFTER USE. 3. ELECTRICAL CONTRACTOR SHALL SUBMIT TO THE LANDLORD A SCHEDULE OF WORK AFFECTING THE MALL'S METER SWITCHBOARD. THE SCHEDULE SHALL IDENTIFY THE ESTIMATED TIME OF WORK, POWER OUTAGES (IF ANY), AND THE DESCRIPTION OF THE WORK TO BE DONE. 4. UPON APPROVAL OF THE ABOVE SCHEDULE BY THE LANDLORD, THE ELECTRICAL CONTRACTOR MAY PROCEED WITH HIS WORK. ANY VARIATIONS IN THE SCHEDULE MUST BE APPROVED BY THE LANDLORD. 5. ANY OUTAGES SHALL BE COORDINATED WITH THE MALL MANAGER, LOCAL UTILITY COMPANY, AND ALL AFFECTED TENANTS FROM THE PARTICULAR SWITCHBOARD, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR TENANT COORDINATION, SAFETY DURING THE PERFORMANCE OF WORK, AND THE AVOIDANCE OF ANY UNSCHEDULED SHUT DOWNS OF MALL POWER. 6. AT NO TIME SHALL THE METER SWITCHBOARD BE LEFT UNATTENDED OR THE COVERS ON THE SWITCHBOARD BE LEFT OFF WHILE WORK IS BEiNG PERFORMED. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO MAINTAIN THE AREA WHILE WORKING AND MAINTAIN SAFETY STANDARDS FOR ALL INDIVIDUALS. 7. UPON COMPLETION. THE METER SWITCHBOARD SHALL BE CLEAR OF ALL DEBRIS. ALL COVERS AND ASSOCIATED HARDWARE SHALL BE REPLACED IN THEIR ORIGINAL LOCATION OR POSITION. 8. ALL CONDUCTORS SHALL BE COPPER INSTALLED IN CONDUIT. 9. KEEP ALL PIPING AS CLOSE TO WALLS AND AS CLOSE TO, THE UNDERSIDE OF THE ROOF FRAMING AS POSSIBLE. 0. COORDINATE POWER AND LIGHTING WORK WITH TENANT DESIGN MANUAL. ELECTRICAL SYMBOLS LIST HOME RUN TO PANEL. CIRCUIT NUMBERS, PHASE, NEUTRAL AND GROUND CONDUCTORS 5 3'x'1 INDICATED. ALL CONDUCTORS TO BE #12 EXCEPT WHERE NOTED. CONDUIT TO BE 1/2" AS NOTED ON PLANS AND SPECIFICATIONS. 1 PARTIAL CIRCUIT CONDUIT INSTALLED CONCEALED ABOVE CEILING OR IN WALL. --- -- — - CONDUIT INSTALLED CONCEALED BELOW FLOOR SLAB OR UNDERGROUND. 0 CONDUIT UP OR DOWN AS MARKED. - GROUND CONNECTION. SINGLE POLE SWITCH, +3'-10" OR AS NOTED. $3 THREE—WAY SWITCHED, +3* -10" OR AS NOTED. =0 20 AMP DUPLEX RECEPTACLE, +18" OR AS NOTED. WP @ WEATHERPROOF GFI RECEPTACLE, +18" OR AS NOTED. DF MOUNT HORIZONTAL. DUPLEX RECEPTACLE FOR ELECTRIC WATER COOLER; VERIFY EXACT =0 LOCATION AND MOUNTING HEIGHT WITH PLUMBING CONTRACTOR. G� GROUND FAULT DUPLEX RECEPTACLE, +18" OR AS NOTED. ISOLATED GROUND DUPLEX RECEPTACLE, +18" OR AS NOTED. FOURPLEX RECEPTACLE, +18" OR AS NOTED. =@ ISOLATED GROUND FOURPLEX RECEPTACLE, +18" OR AS NOTED. LOCATION: STOCKROOM MAINS: 100A MOB Aio SPECIAL RECEPTACLE, NEMA STYLE AS NOTED, +18" OR AS NOTED. N.E.C. DEMAND FACTOR -e SIMPLEX RECEPTACLE, +18" OR AS NOTED. LOAD DESCRIPTION ® FOURPLEX RECEPTACLE MOUNTED ON UNI—STRUT, VERIFY COLOR WITH OWNER. ® DUPLEX RECEPTACLE MOUNTED ON UNI—STRUT, VERIFY COLOR WITH OWNER. = TELEPHONE OUTLET, +18" WITH 1/2" CONDUIT TO ABOVE CEILING. LOAD DESCRIPTION RECEPT- CASHWRAP DATA OUTLET, +18" WITH 3/4" CONDUIT TO ABOVE CEILING. 1 IST 10KW 0 100% REMAINING 6 50% CEILING SPEAKER. 1 O THERMOSTAT (FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL 0 CONTRACTOR). 20 ® CONTROL RELAY. 20 nC LIGHTING CONTACTOR. 360 © DOOR BUZZER, MOUNT AS NOTED. 4 (] PUSHBUTTON, MOUNT +48" AFF OR AS NOTED. 1 20 PANELBOARD. TOP 6'-0". CASHWRAP - CASE LIGHTS 0 JUNCTION BOX. Ch DISCONNECT SWITCH. C �• DISCONNECT SWITCH FURNISHED W/ EQUIPMENT (INSTALLED BY ELEC, CONTRACTOR). 1 MOTOR CONNECTION. RECEPT-SHOW WINDOW ® DUCT TYPE SMOKE DETECTOR WITH SAMPLING TUBES, REMOTE ALARM LIGHT MOUNTED LOC BELOW DETECTOR FLUSH IN CEILING. 7 IA ® CEILING MOUNTED SMOKE DETECTOR 1 1,80 ®4 FIRE ALARM HORN AND STROBE, +80" TO BOTTOM OF DEVICE 20 0 STROBE ONLY, +$0" TO BOTTOM OF DEVICE 20 nF MANUAL FIRE ALARM PULL STATION AND ZONE NUMBER, +3'-10". FF—c-P-1 FIRE ALARM PANEL, TOP +6'-0". 10 NL NIGHT LIGHT. 1 1 NF NON—FUSED. RECEPT-BASS MODULE WP WEATHERPROOF. +3'-10" HEIGHT ABOVE FLOOR TO CENTER LINE OF OUTLET BOX. C AFF ABOVE FINISHED FLOOR. DF ELECTRIC DRINKING FOUNTAIN VERIFY RECEPTACLE MOUNTING WITH PLUMBING CONTRACTOR. ELECTRICAL GENERAL NOTES A. ALLOWANCES ARE TO BE INCLUDED FOR UNFORESEEN CONDITIONS THAT MAY EFFECT THE CONTRACTOR'S SCOPE OF WORK. MINOR DEVIATIONS REQUIRED FOR ACCOMPLISHING THE INTENT OF THIS DESIGN ARE TO BE INCLUDED IN THAT ALLOWANCE. B. ALL RECESSED PANELBOARDS ARE TO BE INSTALLED WITH A MINIMUM OF (2) 3/4" CONDUITS STUBBED UP TO ACCESSIBLE CEILING SPACE FOR FUTURE USE. C. ALL PANIEL.BOARDS, SWITCHBOARDS AND LINE VOLTAGE CONTROL EQUIPMENT SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTING, SERVICING OR MAINTENANCE OF EQUIPMENT. MARKING SHALL BE SELF ADHESIVE, COMMERCIAL LABEL CONFORMING TO N.E.C. 110.16 AND A.N.S.I. Z535.4 AS MANUFACTURED BY IDEAL OR APPROVED EQUAL. D. ALL CONDUIT INSTALLED INDOORS TO BE ELECTRICAL METALLIC TUBING (EMT), MINIMUM 1/2" AND CONDUCTORS TO BE A MINIMUM OF #12 THHN/THWN, COPPER UNLESS NOTED OTHERWISE. ALL POWER CONDUITS SHALL HAVE 2 #12 CONDUCTORS AND 1 #12 GROUND CONDUCTORS IN 1/2- CONDUIT, UNLESS NOTED OTHERWISE. E. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE. F. TELEPHONE CABLE TO BE FURNISHED AND INSTALLED BY OTHERS. ALL CABLING TO BE PLENUM RATED. G. ELECTRICAL CONTRACTOR TO INCLUDE GROUND WIRE IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH N.E.C. H. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND DETAILS FOR THE EXACT LOCATION OF ALL LIGHTING FIXTURES AND ANY OTHER EQUIPMENT INSTALLED IN THE CEILING SYSTEM. VERIFY EXACT MOUNTING HEIGHTS AND FINISHES WITH ARCHITECT PRIOR TO ROUGH --IN. I. CONTRACTOR SHALL COORDINATE INSTALLATION OF ELECTRICAL WORK ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF PLUMBING AND MECHANICAL INSTALLATION. CONDUIT RUNS TO BE RUN THROUGH TRUSSES WHERE POSSIBLE. J. ELECTRICAL CONTRACTOR TO VERIFY EXACT PLACEMENT OF ALL DEVICES SHOWN ON THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. K. BRANCH CIRCUITS SHOWN WITH TWO GROUND CONDUCTORS SHALL HAVE ONE EQUIPMENT GROUND CONDUCTOR (GREEN) AND ONE ISOLATED GROUND CONDUCTOR (GREEN W/ YELLOW STRIP) INSTALLED IN RACEWAY. L. ADDITIONAL EXIT AND EMERGENCY LIGHTS MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. ADDITIONAL FIXTURES SHALL BE ADDED AS DIRECTED BY THE LOCAL AUTHORITY. PANEL: L SYSTEM: 208/120V., 3PAW FEEDER: SEE RISER DIAGRAM OPTIONS: LOAD SUMMARY LOCATION: STOCKROOM MAINS: 100A MOB ACTUAL CONNECTED WATTAGE larsonbinkiey.com N.E.C. DEMAND FACTOR N.E.C. DEMAND WATTAGE NEMA ENCLOSURE: 1 CABINET MOUNTING: SURFACE LUGS: AIC RATING: LOAD DESCRIPTION BKR BKR NOTE SIZE POLE WATTS OCT NO. PHASE OCT NO. WATTS NOTE BKR BKR POLE SIZE LOAD DESCRIPTION RECEPT- CASHWRAP 20 1 IST 10KW 0 100% REMAINING 6 50% '1080 1 A 2 720 0 1 20 REGEPT-CONVENIENCE SALES RECEPT-CASHWRAP IG 20 1 LOC 360 3 B 4 5W LOC 1 20 SENSORMA11C CASHWRAP - CASE LIGHTS 20 1 500 5 C 6 180 1 20 RECEPT-SHOW WINDOW RECEPT -VIDEO SURVEILENCE 20 1 LOC 1 360 7 IA 8 1 1,80 1 1 20 RECEPT-SHOW WINDOW SPARE 20 1 9 B 10 1,200 C1 1 1 20 STORE SIGN RECEPT-BASS MODULE 20 1 720 11 C 12 360 1 20 RECEPT-MANAGER'S DESK RECEPT-TELE PHONE EQUIP 20 1 LOC 500 13 A 14 360 1 20 RECEPT- MANAGER'S DESK IG RECEPT RESTRM/STOCKRM 20 1 540 15 B 16 1,000 C1 1 20 UNI -STRUT SIGN EMERG. LIGHTS 20 1 LOC 444 17 C1 18 600 C1 1 20 LIGHTS -STORE FRONT LIGHTS - SALES HI -BAYS 20 1 C2 980 19 A 20 550 C1 1 20 LIGHTS - STORE FRONT TRACK FITTING ROOM LIGHTS 20 1 C3 120 1 21 B 22 3,600 1 1 30 WATER HEATER UNI-STRUT - LIGHTS 20 1 C3 1,026 23 C 24 544 1 TO 1 20 LIGHTS - STORAGE/RESTROOM UNI-STRUT - LIGHTS 20 1 C3 828 25 A 26 828 C4 1 20 UNI -STRUT LIGHTS SPARE 20 1 27 B 28 1 20 SPARE LIGHTS29 0 30 792 1 20 UNI -STRUT LIGHTS SPARE 20 1 1 31 A 32 792 C4 1 20 UNI -STRUT LIGHTS SPARE 20 1 33 B 34 1 20 SPARE VAVA 15 1 180 W G 36 180 1 20 DRINKING FOUNTAIN SPACE ONLY 1 37 A 38 1 SPACE ONLY SWE ONLY 39 B 40 SPACE ONLY S PACE ONLY 1 41 C 42 792 1 C4 1 1 20 LIGHTS -STORE FRONT PHASE A: PHASE B: PHASE C: 7,158 7,320 7,110 W W W Y:\ Ro CONNECTED DEMAND 21,588 W 25,430 W 60 A 71 A s�ctNe12006101200602.11\01200602.11.C4L\0120060211 ME°Gbard.xls ELECTRICAL SERVICE LOAD SUMMARY LOAD DESCRIPTION ACTUAL CONNECTED WATTAGE larsonbinkiey.com N.E.C. DEMAND FACTOR N.E.C. DEMAND WATTAGE LIGHTING 11,218 125% 14,023 TRACK LIGHTING 550 150 W/2 FT 1 0 FT 688 RECEPTACLES 6,040 IST 10KW 0 100% REMAINING 6 50% 6,040 AIR CONDITIONING ' HEATING * 0 100% FULL A/C LOAD 0% FULL HEATING LOAD 0 0 0 CONTINUOUS WATER HEATER 3,600 125% 4,500 MISCELLANEOUS 160 100% 180 TOTAL WATTS TOTAL AMPERAGE NOTES: * USE GREATER LOAD OF THE TWO CATA3ORIES "** PIECES OF EQUIPMENT: 1-2 a 100%, 3 = 90%, 4 = 80%, 5 = 70%. 8 AND MORE = 65% REQUIRED ELECTRICAL SERVICE 25,430 31 60 AMPS PANEL SCHEDULE NOTES General Notes: r`s;;'LLn}y'N<CIRCUITS SHADED ARE EXISTING TO REMAIN. BALANCE PANELS WITHIN 10% PHASE TO PHASE. Circuit Key Notes: LOC HANDLE LOCK "OFF/ON" CLAMP DEVICE HACR HEATING, AIR CONDITION AND REFRIGERATION RATED BREAKER TO ROUTE CIRCUITTHROUGH TIMECLOCK, REFER TO LIGHTING CONTROL DIAGRAM. C1 ROUTE CIRCUIT THROUGH CONTACTOR "C1", REFER TO LIGHTING CONTROL DIAGRAM. C2 ROUTE CIRCUIT THROUGH CONTACTOR "C7, REFER TO LIGHTING CONTROL DIAGRAM. C3 I ROUTE CIRCUIT THROUGH CONTACTOR "C3', REFER TO LIGHTING CONTROL DIAGRAM. C4 IROUTE CIRCUITTHROUGH CONTACTOR "C4', REFER TO LIGHTING CONTROL DIAGRAM. ALL PANELS SHALL BE INSTALLED ON PLYWOOD BACKERBOARDS. El [1 F-1 F1 El 110 24/7 TIMECLOCK SHALL CONTROL THE FOLLOWING: -STOREFRONT SIGNAGE -SHOW WINDOW LIGHTING -SHOW WINDOW RECEPTACLES -ENTRY LIGHTING APPROX. 3T' L. L. APPROVED AS NOTED 6/9/2 PANEL 'L' ml 2 _ Z Z �,5 4 gCA > 7 GROUND TO BUILDING STEEL. C 1 rn RISER DIAGRAM NOT TO SCALE RISER DIAGRAM SCHEDULE CIRCLE TAG WIRE AND CONDUIT EXISTING 60A, 48OV, 3 PHASE, NEMA 1 FUSED DISCONNECT SWITCH. Q CONTRACTOR TO INSTALL (3) KTS-60 FUSES. PROVIDE (3) #8, (1) 010 GND IN LANDLORDS 1 1/4" CONDUIT. FIELD VERIFY. PROVIDE NEW 60A, 48OV. 3 PHASE, NEMA 1 DISCONNECT SWITCH. CONTRACTOR TO INSTALL (3) KTS-50 FUSES. 4 PROVIDE NEW 30 KVA FLOOR MOUNTED TRANSFORMER. 5 PROVIDE (4) 013, (1) #8 GROUND IN 1 1/4" CONDUIT WITH #8 ISOLATED GROUND. 6) I PROVIDE NEW 120/208V, 100A MOB PANEL L. O Larson Binkiey, Inc. 6363 College Blvd., Suite 400 Overland Park, Kansas 66211 Florida Certificate of Authorization Number 8039 Christopher R. Larson, PEC043082 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to co yrtpht protection as an "arahiteatural work" under sso. 102 of the copyright oat, 17 u.S.C. As amended december 1890. The protection Includes, without limitation. the overall form. arrangement and composition of spaces. and elenunts of the design. Under such protection, unauthorized use of These drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 40 L_ 0 U�- a °400 r1% _ C P% tU OCA M oUo • W du = o �. o z '� • O �- Q ■= i-- 4� o u *= W Z Ec m r J 0 0 CL M Vf !V Vf 4A DATE. 6/01 /06 SHEET: SCALE' DRAWN 9Y E3 L.jV�I PIOECT Na. 0MM06024 T 913-383-2621�2o/0(e F 913-383-2831 larsonbinkiey.com COPYRIGHT 2006 John C. Coultari PE0030426 2246 COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to co yrtpht protection as an "arahiteatural work" under sso. 102 of the copyright oat, 17 u.S.C. As amended december 1890. The protection Includes, without limitation. the overall form. arrangement and composition of spaces. and elenunts of the design. Under such protection, unauthorized use of These drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. 40 L_ 0 U�- a °400 r1% _ C P% tU OCA M oUo • W du = o �. o z '� • O �- Q ■= i-- 4� o u *= W Z Ec m r J 0 0 CL M Vf !V Vf 4A DATE. 6/01 /06 SHEET: SCALE' DRAWN 9Y E3 L.jV�I PIOECT Na. 0MM06024