HomeMy WebLinkAbout4585 St Johns Pkwy (2)Permit # `5 :5 0
.Job Address:
U tJ
Description of Work: ��; tQ
Historic District: Zoning: VaIuc of Work: $ c ,�)o RECEIVED
CITY OF SANFORD PERMPC APPLICATION
Date:
RECE/vEn
M/A
Permit Type: Building .✓'�•'Elcctrical -� Mechanical r Plumbing ' Fire Sprinkler/Alarm Pool _ Mug
Electrical: New Service -- N of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential Non -Residential --Replacement New_ /' ~(Duct Layout &Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures _ _ If of Water & Sewer Litres It of Gas Lines
Plumbing/New Residential: It of Water Closets_ Plumbing Repair - Residential or Commercial
Occupancy Type: Residential Commercial ✓�hldustrial Total Square Footage:
Construction Type: 1 It of Stories: I It of Dwelling Units: _ Flood Zone: (FEMA form required for ocher than h:)
Parcel #: +-� �� - ` Gl_ 2)C2 ' �� _ f-S�C� C'J - c7C� ,� CU (Attach Proof of Ownership &Legal Description)
Owners Name & Add
Contractor Name & Address:(
t 0� (trc�� ( e,' c1 State License Nuud>er:
Phone & Fax:,) rl n- t (�'<-, Coutact Pel -son: 1'Iwuc:
Bonding Company: r\ -
Address: % A~
Mortgage Lender: p
Address: , V
Architect/Engineer: —_ phone:
Address:
Application is hereby made to obtain a permit to do the work and installations as indicated. l certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELEC:"IRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONF..RS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSUL'(' W CCH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In. addition to the requirements of this permit, there may be additional restrictions applicable to (tris property that may be found in the public records of
this county, mud there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requiremen s At�I arida Lien Law, FS 71 f
Signature of Owner/Agent Date Signature ofCoulractor/Agent Date
Print Owner/Agent's Name
Signature of Notary -State of Florida Date
Print Contractor/Agent's Name
f %'OBBIE BLANTM'
f,Ay CO�11.041SGIOt`I # DD 188491
EXPIN,`0: Fabruary 26, 2007
Owner/Agent is Personally Known to Me or Couttactor/Ag(ent-JWO•3-NU Pet'sonaliy-Known to"melon-
Produced ID
Cr I k, I
APPLICATION APPROVED BY: Bldg _ ,/ '� v% �V Q r Zoning: �« I ' �Q' Utilities: 41�j0L'5� _ I D. 'may
(Initial & Date) (Initial & Date) (Initial & Date) (hri
Special Conditions:
S/51 - `✓Z6°
, S
0
t13ldte)
�� t
-EXISTING ONE HOUR FIRE RATED TENANT 5EPARATION WALL (UL DE51GN #419)
_ 55,
4'-10" 2'-G" - 3G'-8"
OPHOOK
OK SINK--_tj (0)_
C10
a D HANDDE0 NAND
51NK O 0 0OSINK P I H.W.
SMOKE RICE (floor
DEEP FRYER SALAMANDER HOUSE COOKL PREP. HEATER
G-WOK5 INK mounted)
L---------- ----� -_------------ --�
F.D.0
,�----HOOD 24' PIA511 GUARD
c�
EATING WAITING AREA i cm F.D.
WALL LEGEND
EX15T TO REMAIN
NEW FULL HEIGHT WALL
TOILET FRONT
3 5/8" METAL
@ IG"0.
N COLINFER RICE I HOT HOLDING
wnF'K TnP RFF IA/ARAAFR 1 ILII"i GAIN MARIE TABI e 3'-0" X 7-0"
24" DKAFT CURTAIN �
5EE DETAIL A- I
000
L - 000 D5HELVE5 ABOVE
_]
(15TING ONE HOUR FIRE RATED TENANT SEPARATION WALL (UL DE51GN #419)
FLOOR PLAN SCALE: l/4" =1'-0"
NEW OR EXISTING 5U5PENDED
GRID ACOU5TIC CEILING
5ECTION A
NT5 A -I
cV E CA CV
�da5hed area
1 8" min knee Space
min.
HAND SINK SIDE
TOILET SIDE Grab Bar Detail
ADA DETAILS
T ROCK
�_5
`.NER (1 ") @ G'-0" O.C.
IG CONCRETE FLOOR
Storage
space
Sealed to 1G 11VV1
CABINET FOR THE 5TOKAGE 5ELF-CL051NG�
OF DETERGENT5 AND CLEANING
COMPOUNDS U5ED IN THE
DAILY OPERATION _ y
-------------
NOTE!
Interior counter walls, Including the rear and under
5urface5 of counters, Shall be of easily cleanable
i and washable, con5tructlon and shall be at least
equal to kitchen wall fml5he5. .
I ----- Z44 ------------J
FRP Coat
-�- - - - - - - - - - - - -
m
N
FRONT
ADA REQUIREMENT NOTES
RESTROOM CONDITIONS
Toilet paper dispensers must permit continuous paper flow and mounted 1'-9"
center to fin. floor.
Hot water and drain pipes under lavatories shall be insulated or otherwise
configured to protect against contact.
There shall be no sharp or abrasive surfaces under lavatories.
If self closing valves are used on faucets, faucets shall remain open for a minimum
of ten seconds.
All stresses on gfab bars and components shall be based on 250 Ib.
Paper towel dispenser to be located at a height of 44" above finished floor maximum.
Provide loop type accessible door hardware on toilet stalls.
block Provide signage on restroom doors adjacent to latch side of door at 60" above fin. floor.
Use non -glare finish grade 2 braille and raised letters (1/32").
All doors min. width 2'-8" clear at 90 degrees open.
BOTTOM OF/
ROOF DECK
ACOUSTICAL-�
CEILING
1 LAYER 5/8" SHEET
ROCK BOTH SIDES, 1 HR.
FIRE RATED.
SERVICE COUNTr"
SERVICE COUNTER
TOTAI,- LENGTH: 12'-6"
TOTAL HEIGHT: 4'-0"
TOTAL WIDTH: 2'-6"
MATERIAL: 1" thick plywood
w/ FRP coating
3 5/8" METAL
STUDS @,) 16" O.C.
LOOR
SECTION THRU DRAFT CURTAIN NTS
A-1
SITE PLAN N.T.
PROJECT DATA:
BUILDING SQUARE FOOTAGE: 1115 SQ. FT..
CODE CLASSIFICATION:
1. FLORIDA BUILDING CODE 2001 EDITION
2, FLORIDA FUEL GAS CODE 2001 EDITION
3. FLORIDA MECHANI01 CODE 2001 EDITION
4. FLORIDA PLUMBING CODE 2001 EDITION
5. NATIONAL ELECTRICAL CODE 2002
6. THE LIFE SAFETY CODfli, 2000 EDITION
TYPE OF CONSTRUCTION: V -B
OCCUPANCY CLASSIFICATION: M
OCCUPANCY LOAD: 8
EMPLOYEE: 4
TOTAL: 12
SPRINKLER: YES
(ANY ALTERATION TO EXISTING SPRINKLER SYSTEM,
SPRINKLER CONTRACTOR SHALL SUBMIT THE SHOP
DRAWING FOR PERMIT AND APPROVAL.)
FIRE SAFETY NOTE:
1. CLASS -B (FLAME SPREAD 26-75, SMOKE -DEVELOPED INDEX 0-450)
INTERIOR FINISH FOR VERTICAL EXITS AND ET PASSAGEWAYS,
2. CLASS -C (FLAME SPREAD 76-200, SMOKEDEVELOPED INDEX 0-450)
INTERIOR FINISH FOR EXIT ACCESS CORRIDORS AND OTHER EXIT WAYS.
3. CLASS -C (FLAME SPREAD 76-200, SMOKEDEVELOPED INDEX 0-450)
INTERIOR FINISH FOR ROOMS AND ENCLOSED SPACES.
4. FIRE EXTINGUISHER, PER 2000 N.F.P.A. #10.
5. KITCHEN SUPPRESSION SYSTEM PROTECTION, PER APPLICABLE
PROVISIONS 2000 N.F.P.A. #96, AS MODIFIED.
EQUIPMENT SCHEDULE (ALL equipment are N.S.F. approved)
NO.
EQUIPMENT
MODEL NO.
MANUFACTURER
1.
CHINESE RANGE STOVE
WR -600
WIN
N.S.F.
2.
HOOD
24'-0"
WIN
N.S.F.
3.
DEEP FRYER 2
#14
PITCO
N.S.F.
4.
SMOKE HOUSE
WSH-200
WIN
N.S.F.
5•
RICE COOKER
RER-55A
RINAI
N.S.F.
6.
HOT HOLDING UNIT
WST-3
WIN
N.S.F.
7•
RICE WARMER
THA -803
ZOARUSHI
N.S.F.
8•
BAIN MARIE
SP60-18M
BEVERAGE -AIR
N.S.F.
9.
WORK TOP REF.
WTR48
BEVERAGE -AIR
N.S.F.
10.
3 -COMP. SINK
412-22-3-24 RL
EAGLE
N.S.F.
11.
FOOD PREP. SINK
412-22-1
EAGLE
N.S.F.
12.
HAND SINK 2)
HSA -10
EAGLE
N.S.F.
13.
MOP SINK
24" x 24" to be proyided b
lumber
N.S.F.
14.
WALK-IN FREEZER
'-0" x 8'-0"
AMERIKOOLEg
N.S.F.
15.
WALK-IN COOLER
8'-0" x 8141
AMERIKOOLER
N.S.F.
16.
HOT WATER HEATER
BTR -120 71 Gal.
A.O. SMITH
N.S.F.
17.
SHELVING metal
CUSTOM
WIN
N.S.F.
18.
COUNTER
CUSTOM
WIN
N.S.F.
19.
TABLE stainless steel
CUSTOM
WIN
N.S.F.
r; `, SIMM SII
4 •1 r!
� r
18 Lo0�3Y 67 CD 61 d � ® 6® t/ 9
PLANS REVIEWED
CITY SA Final ln5{).,
Dr -
GENERAL NOTES: - _ - -
1. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR
TO ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING
THAT FURNISHED BY SUBCONTRACTORS,
2. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS; DO NOT SCALE DRAWINGS TO
DETERMINE ANY LOCATION. THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY
OCCURS PRIOR TO CONTINUING WITH WORK:
3. ALL CONSTRUCTION SHALL COMPLY WITH THE APPLICABLE BUILDING CODES AND
LOCAL RESTRICTIONS.
4. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING
MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER
SHOWN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL
BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY
DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK.
5. ALL WORK SHALL BE ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE
HIGHEST INDUSTRY STANDARDS. ALL MATERIALS SHALL BE INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS.
MATERIALS AND METHODS SHALL CONFORM TO THE APPROPRIATE NATIONAL TRADE
BOOKS; I.E. TILE COUNCIL OF AMERICA, HANDBOOK FOR CERAMIC TILE INSTALLATION;
ARCHITECTURAL WOODWORK INSTITUTE, "QUALITY STANDARDS." ETC.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SAFETY, AND SHALL TAKE ALL
NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKERS AND OCCUPANTS AT ALL
TIMES.
7. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO STATE
AND LOCAL REQUIREMENTS.
8. REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING
FIRE PROTECTION SYSTEMS. MODIFICATION TO FIRE PROTECTION SYSTEMS SHALL BE
PERFORMED BY A FIRE PROTECTION CONTRACTOR, WHO SHALL OBTAIN A PERMIT
FROM FIRE LOSS MANAGEMENT PRIOR'TO WORK.
9. DECORATIVE MATERIALS, DRAPES, HANGINGS, ETC., SHALL BE NON FLAMMABLE OR
FLAME -PROOF PER STATE FIRE MARSHALL REQUIREMENTS.
10. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO
THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES.
11. CONTRACTOR SHALL SUBMIT SHOP DRAWING OF ANY SPRINKERS SYSTEM CHANGES
FOR APPROVAL.
12. FIRE SUPPRESSION, GAS, AND WALK-IN COOLER/FREEZER CONTRACTOR SHALL SUBMIT
SEPARATE PERMIT APPLICKHON FOR APPROVAL.
1
FINISH SCHEDULE
KI'T'CHEN AREAS:
FLOOR: Quarry tile, coved to the walls, commercial grade.
WALLS: Stainless Steel behind hood area and FRP paneling
in other area.
CEILING: 2x4 Lay -in acoustical ceiling, non -perforated, non -
fissured, smooth, washable, light -in color. Fire -rated,
EATING & WAITING AREAS:
FLOOR: Ceramic tile, coved to the walls, commercial grade.
WALLS: Gypsum Firecode painted W/2 -coats of epoxy paint,
smooth surface, washable.
CEILING: 2x4 Lay -in acoustical ceiling, commercial grade.
TOILET AREAS:
FLOOR: Ceramic tile, coved to the walls, commercial grade.
WALLS: Gypsum Firecode painted W/2 -coats of epoxy paint,
smooth surface, washable.
CEILING: 2x2 Lay -in acoustical ceiling, commercial grade.
'�' A i E' D
(<2
Sanford nr-,e on
FRANK D. MIL,ETO A.I.A.
14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 F n
(908) 876-9400 LESS SUIED
WF ARCHITECT -PROFESSIONAL PLANNER \ A1065084
L102012
CHINA 5TAR
5T. JOHN5 PLAZA
RINEHART ROAD f 5T. JOHNS PARKWAY
5AN FORD, FL
SCALE: 1/4"=1'-0" DRAWING NO.: 14405 DRAWN BY: JU
DATE: 04/27/05 A -I ( I of 4) REVISED:
FLOOR PLAN
FOOD SERVICE CONSULTANT
LAM CONSULTING COMPANY, INC.
108 MADISON STREET, NEW YORK, NY 10002
PHONE: 212-732-3450 FAX: 212-732-9145
5 A-15 A7,�
--
A-27,223` A-14,16, 18 A-33,3_537
EF- I MUA- I EF -2
COUNTER
� WAITING
WOO( T(1P PFF RICE HOT H(k5M6 MAllm IviftRil I TABLE
KITCHEN
\-13
TOILET
Ii -A-5 I / GFWL 19 I
ELECTRICAL PLAN SCALE: 1/411=11-011
PANEL: A
WARMER
UNIT
A 6,8, I 0
A_ -2\I
A-23
CONNECTED
LOAD
LIGHTING FIXTUKE5
A25
GFI
FI
AIR-CONDITIONING
EQUIPMENT
VOLTAGE: 120/208V
J GFI
it/ -A-2
KITCHEN
\-13
TOILET
Ii -A-5 I / GFWL 19 I
ELECTRICAL PLAN SCALE: 1/411=11-011
PANEL: A
PANEL SCHEDULE
KITCHEN EQUIPMENT
CONNECTED
LOAD
LIGHTING FIXTUKE5
CONNECTED
LOAD
MAINS: 200A MCB
CONNECTED
LOAD
AIR-CONDITIONING
EQUIPMENT
VOLTAGE: 120/208V
I
PHASE:
3
WIRE: 4
MOUNTING: SURFACE
DESCRIPTION
WIRE
BREAKER
POLE AMP
WATTS
CKT CKT
NO. NO.
WATT5
BREAKER
AMP POLE
WIRE
DE5CRIPTION
A B C
A B C
5PARE
3.
.....................::::::.::::::::::::::
I
2
960 .......................
20
I
12
RTU RECEPT.
5PARE
MAKE-UP AIR FAN
5472
TOILET
.
3 4
00
II
20
I
12
RTU LIGHT
RECEPT. (EATING WAITING AREA)) 12 I 20
360
5 6
996'4
110 3 6
1 RTU
LIGH 15 EATING WAITING AREA)
12
I 20
3 2p
300
7 8
9984
7.
WORK TOP REF.
1200
LIGHT5 (EATING � WAITING AREA
12
1 20
;: 600
� 480 �
36015
9 Io
I
9984
LITHGS KITCHEN 12 I 20
1440
I I 12::::
........... :::::.::::::::....^ ,,,,.�
::::.................. �� ,
1824
120 I 12
COOLER FREEZER LIGHTS
LIGTH * FAN ; OILET 12 1 20
13 14
3
20 12
MAKE-UP AIR FAN
RECEPT, COUNTS 12 1 20
_1.80.... _
16
1824 ;
1 f,•'A
420
420
RECEP. KITCHEN 12 I 1 20
17 18
RECEPT. (TOILET) 12 I 1 20
180
19 20
TOTAL CONN. LOAD:
15,565
WORK TOP REF. 12 1 20
1200
TOTAL CONN. LOAD:
21 22
TOTAL CONN. LOAD: 29,952
APPLY NEC 220-20 DEMAND FACTOR:
65% x 15588 = 10132.2
RICE WARMER 12 20
I
480
23 24
APPLY NEC 220-31 DEMAND FACTOR:
100% x 29952 = 29952
TOTAL DEMAND LOAD: 10 1 32.2 + 5675
13AI A IE
NMR
12
I 20
1020
:::::::::::::::::::::
:::::::::::::::::::::::::::::::::::::•
25 26
630
:::::::::::::::::::::::.::::::.:::::::
. ..
20
WA -INFREEZER
E -
F I
10
3 20
816
27 28
630
"
816
29 30
1200
20 1 12
51GN
"
816
31 32
....:••:......::
5PARE
EP -2
10
2
3 0
..........:• 816
::::' ""
....................
33 34
...................
:::::::::::::::::::
.....::.....:::
:............::
5PARE
816
35 36
5PARE
8I6
37 38
:::::::::::::::::::::::::::::::::::::::
5PARE
5PARE
39
40
5PARE
5PARE
41 42
..........................................
5PARE
3632 3792 4092
145A AMPS
141.3 AMP5
147.7 AMP5
13618 13158 13628
TOTAL FOR PHA5E
A 17450
B 16950
C 17720
TOTAL CONNECTED LOAD: 52,120
AMP5: 144.8
20 3 12 WALK-IN COOLER
420
....................
A- 12—� A- 12 '—
WALK-IN WALK -I N
COOLER FREEZER
A-26, 28
A-20,22,24 COMP. COMP.
220V, 1/211P, 220V, 3/4HP,
3PH, 20A 3PH, 20A
EQUIPMENT LOAD CACULATION: (PANEL A)
KITCHEN EQUIPMENT
CONNECTED
LOAD
LIGHTING FIXTUKE5
CONNECTED
LOAD
OUTLET5
CONNECTED
LOAD
AIR-CONDITIONING
EQUIPMENT
CONNECTED
LOAD
I
WALK-IN COOLER
1260
COOLER � FREEZER
200
COUNTER
360
RTU
29952
2,
WALK-IN FREEZER
1 260
EATING � WAITING AREA
920
WAITINGfEATING AREA
360
3.
EXHAU5T FAN
4696
KITCHEN AREA
1440
KITCHEN
180
4.
MAKE-UP AIR FAN
5472
TOILET
480
TOILET
1 80
5.
RICE WARMER
480
5IGN
1200
RTU RECEPT.
960
6
BAIN MADE
1020
RTU LIGHT
300
7.
WORK TOP REF.
1200
TOTAL CONN. LOAD:
15,565
TOTAL CONN. LOAD:
4,540
TOTAL CONN. LOAD:
2,040
TOTAL CONN. LOAD: 29,952
APPLY NEC 220-20 DEMAND FACTOR:
65% x 15588 = 10132.2
APPLY NEC 220-10 (B) DEMAND FACTOR:
125% x 4540 =5675
APPLY NEC 220-13 DEMAND FACTOR:
100% x 2040 = 2040
APPLY NEC 220-31 DEMAND FACTOR:
100% x 29952 = 29952
TOTAL DEMAND LOAD: 10 1 32.2 + 5675
+ 2040 + 29952 = 47,799.2
AMPS: 132.6
200 A
200A
NEMA 3R
ELEC.
LEGEND
SWITCH
DUPLEX CONVENIENCE WALL OUTLET
@ MOTOR
J❑ JUNCTION BOX
75 CFM FAN
FAN MOTOR W/ DISCONNECT
INCANDESCENT LIGHT W110OW BULB
0 RECESSED LIGHTING FIXTURE
ELECTRICAL Ric)ER DIAGRAMS NTS
U15TING ROOF 5Y5TEM
ZINC THREADED ROD COAR5E THREE
(C -CLAMPED TO I -BEAM IN ROOF)
1/4"0 ROD. @5'-0" O.C.
I
I I I I I I I
112" GYP. BOARD
112" OAK 5TKI P 1 /2" OAK 5TRI F --/
2x3 METAL STUD 2x3 METAL STUD
COVERED W/ 11211 COVERED W/ 11211
OAK 5TRI P OAK 5TKI P
SECTION C/E- I
5CALE: NT5
- HOOD LIGHT
2'x4' LAY -IN FLUORESCENT LIGHT FIXTURE
2'X2' LAY -IN FLUORESCENT LIGHT FIXTURE
EMERGENCY LIGHT W/ BATTERY BACK-UP
OUTDOOR REMOTE EMERGENCY EGRESS LIGHT
WI BATTERY BACK-UP
EXIT / EMERGENCY LIGHT W. BATTERY BACK-UP.
LIGHTING NO'T'ES:
1. PROVIDE A MIN. 20 FOOT- CANDLES OF LIGHT ON ALL WORKING SURFACES IN THE
FOOD PREPARATION AREAS, EQUIPMENT AND UTENSIL WASHING AREAS, AT
HANDWASHING LAVATORIES, AND IN TOILET ROOMS.
2. PROVIDE A MIN. 10 FOOT- CANDLES OF LIGHT AT A DISTANCE OF 30 INCHES ABOVE
THE FLOOR IN WALK-IN COOLERS AND FREEZERS, DRY STORAGE AREAS, AND IN ALL
OTHER AREAS.
3. ALL LIGHTING FIXTURES AND LIHGHT BULBS LOCATED
WITHIN FOOD PREPARATION AND STORAGE AREAS SHALL BE SHIELD OR
SHATTERPROOF.
ELEC'T'RICAL NOTES & REQUIREMENTS
1. ALL WIRING TO COMPLY WITH N.E.C., 1999 OR LATEST ADOPTED, AND LOCAL AL REQUIREMENTS.
2. MINMUM CIRCUIT TO BE 20 AMP. BREAKER, (2) #12 IN 3/4" CONDUIT (+GND) UNLESS SHOWN
OTHERWISE.
3. WIRE SIZES BASED ON THW COPPER, A.W.G.
4. PROVIDE DISCONNECTING MEANS AT ALL MOTOR LOADS.
5. VERIFY ALL REQUIREMENTS FOR KITCHEN EQUIPMENT WITH EQUIPMENT SUPPLIER.
6. MAKE ALL FINAL CONNECTIONS.
7. MOUNT ALL ELECTRICAL DEVICES AND SWITCHES AS REQUIRED BY THE ADA AND THE LOCAL
STATE BARRIER FREE RULES.
8. FUSE ALL MOTORS AND MOTOR ASSEMBLIES IN A ACCORDANCE WITH THE N.E.C. 1999 AND
MANUFACTURER'S RECOMMENDATIONS.
9. BALANCE THE LOADS EVENLY BETWEEN THE PHASES OF THE SYSTEM, MINIMUM UNBALANCE OF
3%.
10. MAINTAIN A MAXIMUM VOLTAGE DROP OF 5% THROUGHOUT THE ENTIRE SYSTEM.
11. COORDINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING TRADES IN FIELD.
12. VERIFY ALL EXISTING JOB CONDITIONS AND ACCOMMODATE AS REQUIRED FOR A COMPLETE
INSTALLATION.
13. ELECTRICAL PANEL SHALL BE ENCLOSED INTO THE WALL,
FRANK D. MILETO A.I.A. o
14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853 PL 140T
(908) 876-9400 NL 5 E
ARCHITECT -PROFESSIONAL PLANNER Al°e°�4
L102°12
CHINA 5TAR
5T. JOHNS PLAZA
RINEHART ROAD � 5T. JOHN5 PARKWAY
5AWOPT, FL
SCALE: 1/4"=1'-0" DRAWING NO.: 14405 DRAWN BY: J
DATE: 04/27/05 E-1 (2 o1' 4) REVISED:
ELECTRICAL PLAN, PANEL SCHEDULE, ELECTRICAL RISER
FOOD SERVICE CONSULTANT
LAM CONSULTING COMPANY, INC.
108 MADISON STREET, NEW YORK, NY 10002
PHONE: 212 - 732.3450 FAX: 212 -132 - 9145
a►.
REMARKS:
A. Removable grease catcher (4-1.2.2.6)
B. UL listed vapor light with wire safety guard.
C. Baffle filter set 45 degree. UL listed. (821U).
Filter size: 25"H x 20"W x 211D.
No. of filter: 14.
D. UL listed fire damper.
E, Ducts constructed of No. 16 MSG steel with all
seams, joints, and penetrations welded as
liquid -tight as per NFPA code 96.
HVAC PLAN SCALE: 1/41==-0n
NOTE:
AIR CONDITIONING 5Y5TEM 15
EX15TING AND 5HALL REMAIN.
NOTE: DUILDING PRE55URIZATION =
=O.A. - E.A. x 100%
E.A.
= 8660 - 9675 x 100%
9675
_
-10.4%
AIR BALANCE CHART
(CFM)
UNIT NO.
SUPPLY
RETURN
OUT5IDE
AIR
EXHAU5T
AIR
RTU
2000
E
500
AIR CONDITION UNIT SCHEDULE:
MUA(KITCHEN)
�Make-up Air
Fan Duct
75
8160
MANUFACTURE: LONNOX
EF- I (KITCHEN)
3" AIR SPACE
208/20/1
ALUMINUM RUB RING
4800
EF-2(KITCHEN)
THERMOST
TOTAL AIR FLOW: 2000 CFM
EXHAUST FAN
4800
EF-3(TOILET)
5�---
DUCT SMOKE DETECTOR
PER FMC 403.3
75
TOTALS
FOOD AND BEVERAGE - WAITING AREA
[IPI
8660
9675
CALCULATIONS:
HOOD: 4'x 24'x 100 = 9600 CFM
FAN: (2) 2 HP EXHAUST, 5HP MAKE-UP
EXHAUST DUCT SIZE: 18" x 18" / 144 = 2.25 SQ. Fr.
EXHAUST DUCT AIR VELOCITY: 9600 / 2/2.25 = 2133 FPM
MAKE-UP AIR: 85% x 9600 = 8160 CFM
MAKE-UP AIR DUCT SIZE: 23" x 24"
F. Hood constructed of No. 18 MSG stainless NOTE:
steel, type 304 with fresh air return, All connection INSTALL 5TAINLE55 5TEEL ON THE
and seams were welded as liquid -tight to meet WALL BEHIND KITCHEN EXHAU5T
NFPA code 96 standard .NSF listed No. 1499. HOOD AND EXTEND A MIN. OF 18"
G. Existing masonry wall with 26ga. stainless steel surface. BEYOND THE HOOD IN ALL
H. Fire supression nozzle. DIRECTION5
I. Roof curb.
I" MIN_
DUCT D FROM (CFM)
AIR 5PACE
10" X21
400
S/A
680
E
PROCA5T FA5T
AIR CONDITION UNIT SCHEDULE:
DUCT WRAP
0 CLEARANCE'
�Make-up Air
Fan Duct
75
Exhaust
MANUFACTURE: LONNOX
Fan Duct
3" AIR SPACE
208/20/1
ALUMINUM RUB RING
MODEL. CHP20-OGO- I Y (5 TONS)
G
THERMOST
1 Min.
CV
m
m
SIDE
I" MIN
AIR 5PACE—\-__
GENERAL NOTES:
1. Ventilators acrd installation MUST comply with NFPA code 96 plus all local fire codes.
2. Hood MUST be constructed of not less than 18ga. stainless steel. All seams, joints,
and penetrations shall have a liquid -tight continuous external weld. (2-1.2)
3. Ducts MUST be constructed of not less than 16ga. carbon steel. All seams, joints,
and penetraL on shall be continuous external weld as liquid -tight. (3-3.1)
4. Make-up air MUST be not less than 80% of total exhausted air.
5. The fire extinguisher system MUST be installed by a local liscensed company,
separate plan must be submitted to local Fire Dept, for approval.
6. All electrical work MUST be done by local liscensed electrician.
7. Hood to be hung 3" away from the fire -protected wall.
2 HP/11 120" MIN. 120" MIN:
EF- I 5 HP
_ T MOA- IEM
PROCASTFAST c� _
DUCT WRAP
0 CLEARANCE
Air''
Flow
.�6"- 5alarnander
Deep
Fn/Fr 0 0
I" MIN
AIR SPACE
Air
Flow ,-23"X 24"
�
A 4" X 14---_.___ 14" X Imo__
If�DAMPER FIRE DAMPER`_
NowF
Hood Length 24'
back 51a5h
Wok 5tove
FRONT
VENTILATION PLAN (N.T.S.).
2 HP
EF -2
�_.
LEGEND:
AIR DISTRIBUTION
DUCT D FROM (CFM)
TO (CFM)
10" X21
400
S/A
680
WEIGHT
(LB)
SUPPLY AIR GRILL
AIR CONDITION UNIT SCHEDULE:
R/A
COOK GC -120
75
RETURN AIR DIFFUSER
MANUFACTURE: LONNOX
15
1/4
208/20/1
ALUMINUM RUB RING
MODEL. CHP20-OGO- I Y (5 TONS)
(T
THERMOST
TOTAL AIR FLOW: 2000 CFM
EXHAUST FAN
FLEXIBLE AIR DUCT
OUTDOOR AIR REQUIREMENTS
5�---
DUCT SMOKE DETECTOR
PER FMC 403.3
FAN
RPM
WEIGHT
(LB)
FOOD AND BEVERAGE - WAITING AREA
[IPI
V/C/P
6 PEOPLE @ 20 CFM/PERSON = I GO CFM REQUIRED
AIR DISTRIBUTION
DUCT D FROM (CFM)
TO (CFM)
10" X21
400
12" 401
680
EXHAUST F
I REMARK.: TOILET
QTY, I
MAKE &
MODLE NO.
VOLUME
CFM
SP
IN WC
FAN
RPM
WEIGHT
(LB)
MOTOR SPECS
HP
V/C/P
COOK GC -120
75
0.125
1200
15
1/4
208/20/1
ALUMINUM RUB RING
SWITCG - NEMA -I, TOGGLE, MOUNTED $ WIRED
MOTOR W/ THERMAL OVERLOADS
UL - 705 - "POWER VENTILATORS"
CURB GPNS-17-G8
EXHAUST FAN
REMARK: KITCHEN
Q FY: 2
MAKE &
MODLE N0.
VOLUME
CFM
SP
IN WC
FAN
RPM
WEIGHT
(LB)
MOTOR SPECS
[IPI
V/C/P
PENN VENTILATION
FX-16B(FT)
4800
0.25
1389
200
2
208/60/3
UL 821 BAFFLE TYPE GREASE FILTER
GALVANIZED VENTED PREMANUFACTURED ROOF CURB
GREASE TRAP WITH DRAIN CONNECT
HINGING KIT -FIELD INSTALLED
MAKE-UP AIR UNIT
REMARK: KITCHEN
QTY, 1
MAKE &
MODLE NO.
VOLUME
CFM
SP
IN WC
FAN
RPM
WEIGHT
(LB)
MOTOR SPECS
lip
V/C/P
PENN VENTILATION
MU5018
8160
0.25
580
250
5
208/60/3
CONTROL CENTER -COMBINED SWITCHING
UL LISTED FIRE DAMPER
Roof
PROCA5T FAST
DUCT WRAP
/ 0 CLEARANCE
Af Ir
Flow
Ceiling
m�
Rice
Smoke Cooker
HOU5e
D
PYRO CHEM MODEL
# PCL3.50/3.50
LIQUID UL 300
FIRE 5UPPRE55ION
5Y5TEM W/27 112
FLEM POINTS.
REMOTE MANUAL PULL
5TATION MIN. 10'-0" AND
MAX. 20'-0" FROM HOOD
AUTOMATIC GA5
VALVE
400 CFM PROVIDED
FOOD AND BEVERAGE - KITCHEN
4 PEOPLE @ 15 CEM/PER50N = GO CFM REQUIRED
I nn rFNA PRn\/InFn
MTL CAP W/
BIRD DARRIER
14W
FUSIBLE LINK
360 DEGREE5
FRYER NOZZLE5
#NLRP2
DEEP FRYER
VENT DETAIL (H,W. HEATER
NUM NQZx
#NLA
PLENUM NOZZLES
#NLA
WOK NOZZLE5
#NLR
v -
N
z
ROOF LA5HINGNIS
r � rl--
PLENUM NOZZLE5
#NLA
#NLA
fU51BLE LINK
360 DEGREE5
000000 00
5MOKE RICE
HOU5E COOKER
6 -WOKS
HOOD FIRE SUPPRESSION SYSTEM (N.T.S.)
NOTE:
ACTIVATION OF FIRE 5UPPRE5510N SYSTEM 5HUT5 OFF
ALL FUEL 5OURCE5, GA5 AND ELECTRICITY UNDER THE
HOOD INCLUDING SUPPLY AIR, LEAVE5 EXHAUST FAN RUNNING.
GALVANIZED HOUSING
O
- FILTER
AIR INTAKE
z IHROr GH FILIER
CURB (20 G4. CONSTRUCRON),
3" CONTINQOUS FLASHIrIG
NorL:
MAKE --UP FAN CURB
(APPROX, :36 X36"X,,,12" ABOY� ROOF)
18 GA. SHEET MTL.
MAKEUP FAN FLASHING COLLAR N.1'.S.
CURB (20 GA. 0ONS7RUGrION)
NOTE;
EXHAOST APMbx, 30NX3U � "
(• � 'X12" A50VE ROOF) '
18 GA. SHEET MTL. -
EXHAUST FAN FLASHING COLLAR N.T.s.
FRANK D. MILETO A.I.A.
14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853
or(908) 876-9400 �
ARCHITECT -PROFESSIONAL PLANNER
A106084
L102612
CHINA 5TAK
5T. JOHN5 PLAZA
RI NEHART ROAD � 5T. JOH N5 PARKWAY
5ANFORD, FL
SCALE: 1/4"=1'-0" DRAWING NO.: 14405 DRAWN BY: JU
DATE: 04/27/05 M-1 (3 of 4) REVISED:
VENTILATION PLAN, HVAC PLAN
HOOD FIRE SUPPRESSION SYS'T'EM
FOOD SERVICE CONSULTANT
LAM CONSULTING COMPANY, INC.
108 MADISON STREET, NEW YORK, NY 100112
PHONE: 212-732-3450 FAX: 212-732-9145
GAS RISER DIAGRAM
N.T.S.
DOUBLE
CHECK VALVE
NOTE:
MANUAL SHUT OFF VALVE TO BE UP5TRFAM
UNION TO BE DOWN STREAM OF MANUAL VALVE
MAXIMUM CAPACITY Of PIPE FOR LOW PRE5URE GAS OF 0.5 P51
OR LESS WITH PRESSURE DROP OF 0.5 INCH WATER COLUMN
AND O.GO SPECIFIC GRAVITY
GA5 PIPING CALCULATION
PER FLORIDA FEUL GAS CODE
TOTAL RUN FROM POINTS OF DELIVERY
TO THE REMOTE OUTLET APPROX. 52'-011
TOTAL BTUH =1,076,200
RPZ VAVLE
(BACK FLOW " GA
PREVENTER) 3Ik 1112
M
THERMAL EXPANSION A
ABSORBER PROVIDE
AMTKOL 5T-5
H.W.
HEATER
HOT WATER HEATER Of COMPLIANCE
MANU: A.0.5MITH
MODEL# BTIa,- 120
HEATING OUTPUT OF UNIT: 120,000 BTU/HR
APPROX TANK CAP.: 7 1 GAL -5.
WATER RISF;R DIAGRAM N.T.S.
2" MINIMUM
12"x 12"
FLOOR 51NK
KITCHEN 51NK OR
EQUIP. (ff.)
ALL EQUIPMENT ARE TO 131 INDIRECTLY DRAINED
EXCEPT HAND 51NK5 AND MOP SINK
INDIRECT WASTE DETAIL
aaGrAa-r -rAnik'
G" PVC INLET
PIPE
UNDI5TURDED EARTH
GREASE TRAP DETAIL
(750 GALLON)
RETE PAD
HEAVY DUTY TRAFFIC
TY;i'E K * C
PLUMBING RISER N.T.S.
WATER HEATER PIPING SCHEMATIC N.T.S.
NOTE5:
1. COLD WATER PIPING
2, HOT WATER PIPING
3. NOT WATER HEATER: A.O.5MITH,
. MODEL BTR- 120A (71 GL), 120,000 BTU.
4. 100 PSI PRE55. RELIEF VALVE.
5. A5ME 4 AN51221.22 RATED TEMP. PRE55,
RELIEF VALVE PIPED FULL 51ZE TO DRAIN.
G. SHUT-OFF VALVE,
7. DIELECTRIC UNION (TYPICAL).
6. GAS SHUT OFF f DIRT LEG. SEE GAS K15EK FOR SIZE.
9. CLA5513" GAS VENT, SEE PLANS OR SCHEDULE FOR SIZE.
10. DOUBLE CHECK VALVE.
11. EXPANSION TANK.
12. GALVANIZED DRAIN PAN
13. 1" INDIRECT WASTE PIPE
14. FLOOR DRAIN
GROUT
(TYP. )
G" PVC OK
D.I.P. OUTLET
TO TEST M/H
MIN. G"
5TONE
THE MINIMUM LIQUID CAPACITY 15 TO BE 750 GAL.
( I CU.FT. = 7.48 GAL. / I GAL. = 0.13 CU.FT:)
THE 5TKUCTURE CAN BE BE MADE Of PRECA5T CONCRETE
WITH NO LE55 THAN 4" WALL5 IN NON -TRAFFIC AREA.
IN TRAFFIC AREA5 WALL5 ARE TO BE G" TO 8" THICK,
GREA5E TRAP CALCULATION:
2001 FLORIDA BUILDING CODE- PLUMBING 5ECTION 1003.3
PER TABLE 1003.5.1 AND 5ECTION 1003.5
GREASE INTERCEPTOR CAPACTY IN GALLON=8 5EAT5 X I OGAL X (I OHR/ 12) X I =G4 GAL
MIN, GREA5E INTERCEPTOR CAPACTY=750 GAL
PLUMBING REQUIREMENTS
1. ALL PLUMBING SHALL COMPLY WITH THE LOCAL PLUMBING & HEALTH
DEPARTMENT REQUIREMENTS.
2, INSULATE ALL HOT & COLD WATER LINES ABOVE GRADE WITH 3/4" FIBERGLASS PIPE
INSULATION, WITH VAPOR BARRIER.
3, VERIFY ALL FINAL CONNECTIONS TO KITCHEN EQUIPMENT WITH KITCHEN SUPPLIER
VERIFY ROUGH -IN REQUIREMENTS WITH SAME.
4. MATERIALS SHALL BE AS FOLLOWS:
A: WATER PIPING TO BE TYPE'K' COPPER BELOW GRADE, TYPE'L' COPPER ABOVE
GRADE.
B: WASTE PIPING TO BE CAST IRON, OR PVC PLASTIC.
C: VENTS TO BE CAST IRON, GALVANIZED STEEL, OR PVC PLASTIC PIPE,
D: GAS PIPING TO BE SCHEDULE 40, BLACK STEEL PIPE. PROVIDE AUTOMATIC GAS
SHUT-OFF VALVE IN COOKING EQUIPMENT SUPPLY MAIN AS REQUIRED FOR
COOKING EQUIPMENT FIRE PROTECTION SYSTEM. VERIFY & COORDINATE
WITH KITCHEN EQUIPMENT SUPPLIER.
5. ALL INDIRECT WAS'T'ES EXCEEDING 24" IN LENGTH SHALL BE TRAPPED.
6. PROVIDE CLEANOUTS REQUIRED, & AT THE BASE OF ALL STACKS.
7. ALL MATERIALS USED WITHIN RETURN AIR PLENUMS SHALL BE APPROVED FOR SUCH
USE.
8. PROVIDE FIXTURE STOPS AT ALL PLUMBING FIXTURES.
9. PROVIDE ALL FITTING & ACCESSORIES AS REQUIRED FOR A COMPLETE
INSTALLATION.
10, HOT WATER SUPPLIED TO LAVATORY FIXTURES SHALL NOT EXCEED 120°F.
11. HANDICAP PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE
ADA REQUIREMENTS & LOCAL STATE BARRIER FREE REQUIREMENTS.
12. COORDINATE ALL WORK IN FIELD WITH ARCHITECTURAL, MECHANICAL &
ELECTRICAL TRADES.
13. VERIFY ALL EXISTING JOB CONDITIONS & AS REQUIRED FOR A COMPLETE
INSTALLATION.
FRANK D. MILETO A.I.A.
14 BEAVER BROOK DRIVE, LONG VALLEY, N.J. 07853
(908) 876-9400
WF ARCHITECT -PROFESSIONAL PLANNER
CHINA STAR
ST. J011N5 PLAZA
RINEIIART ROAD � ST. J011N5 PARKWAY
SANFORD, FL
A106081
L102612
SCALE: 1/4"=1'-0" DRAWING NO.: 14405 DRAWN BY: TU
DATE: 04/27/05 P-1 (4 of 4) REVISED:
PLUMBING PLAN, GAS RISER
WATER RISER
FOOD SERVICE CONSULTANT
LAM CONSULTING COMPANY, INC.
108 MADISON STREET, NEW YORK, NY 10002
PHONE: 212 - 732 - 3450 FAX: 212 - 732 - 9145