Loading...
HomeMy WebLinkAbout2025 WP Ball Blvd (int alt) (a)Permit # .lob Address Description of NVorlc: Ilisloric District: Zoning: Permit Type: Building }X— Electrical k Electrical: New Service – # of AMPS Mechanical: Residential Non -Residential Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets Occupancy Type: Residential Commercial / Construction Type: ! V # of Storics: / Ja( - / 7 • --.,o • :SQQ • V Parcel #: — 2a • 19. Owners Name & Addresses�,,�p„n 3�dtc zwo c,. I Contractor Name & Address: 4.41 /Q1?b i i2nt o (-4 - dd$_ J. Phone & Fsi CJ_l Bonding Company: Address: Mortgage Lender: _ CITY OF SANFORD PERiINIIT APPLICATION Date: A -N P-0 X,00 3a -4--1-1 Value of Norte S f C1 n e7 d V Mechanical k Plumbing _ Fire Sprinklier/Alarin Pool__ _ Addition/Alteration Change of Service Temporary Pole — Replacement New (Duct Layout & Energy Calc. Required) # of Water & Sewer Lines # of Gas Lines . Plumbing Repair – Resid ial c r Commercial Industrial Total Square Foottge4 _ # of Dwelling Llnit�: Flood Zone: (FEI11A form required for other than X) w a. podgy t' • 0000 00 Q. O (Attach Proof of Ownership & Legal Description) LLC— /Deo y-& L.0 "& /an y bE 0 0 'a• iaa _ Phonc:-4G q. • %.-% ej Contact Person: (03 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNFY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of per 't is verification th I will not e owner of the property of the requirements of Florida Lien Law, FS 713. S' a ure o' wmer/Agent N%II I I11//1/ Dae Signature of Contractor/Agent Date Pra caner/Agent' Name `e �.• �XPIRf'•y,• �j� Pri C ntracto is Name G• Signature of Notary -State cF1sQridtJ a /� = Signature of Notary- ate of Florida Date �a`y ��' �V FLORENCE A. DE GRAVE 4DE W4-# �C``�� * MY COMMISSION # DD 164280 Owner/Agent is rsonalGj�Cf�yy�tMA4et1r J�N� Cont nt igXPIRF9?�(� iQ to c or _ Produced 1D / __`` C.� �ti1ii11����� In �. APPLICATION APPROVED BY: Bld J v zoning: x'11 '2' lb'D� Utilities: 2 �g FD: �3 (Initial & Date) (Initial & Dale) (Initial & Date (In ' Special Conditions: UrWIYnWncT FEES $ wo -PIC- FLAT SCREEEN TV - - - - -- - - - - - - - - - - - - - - - - - -, I I I I I I I NAIL DRYER 34" HIGH 13" DEEP UNDER TV I I I I I I I I - + -}-% - - - + - + - i_ - -f- - --- -}-• - +- - - -I- - +_ -- +_ - { °' -'t- - }- - - i-- - I- - - .I-. - f-.. _.-_ _ r `--- - T__ I 1' AFFAFF I I I I I I I I I I �jI I I II IQ I F- I I I I I I I I I I I I II I I I CEILING @ ISTING �0' AFFI� I L GIHTING SY NG ITEOM AND FIRE AN� I I I I I I I/ I I IL - -�� I b I 1 256 CF141 I I I I 1266 CFM I I I I 1266 CFM I I I I 1266 CFMI I PROI ECTIONVO REMJIN 1266 CFMI 1 1 I I I 12b -4W _ • i + + - + _ 4W + - fi - f - l- - - - - 4W - _r - _ 4W_ I - I - - _ T 4W- ) - T L - t 4W- + - +- + _ _ + _ + _ + - -- zz � � I I I I 13,15,17 I I I I I � I I I �� I I I 1 ► I ��" j"� I I � yr-�-- �--�__ --�` �i �_I`` � I I I I I I I I I I I- I- I I + - - _ _ _ } NEW (OgCF + + T fi - L -I- - -y " �_ - �- I - _ I _ - I- - - I - - ' 1 I 14 EXHAU T FAN I I 1 _ �� �` I _- 8" ROUND METAL DUCT I I I I I I 4 I _ .__. ,- _ I 1 1 - __-__ _ _ - - - - SOFFIT @ 9' AFF I I _ - ^-~ _r �USE 3-5/8" METAL STUD FRAMING I , I z �4FLEXRqUND ME AL DUC -fII0 I FINISHED WITH 1/2" DRYWALL 0 _ - - _ _ _ _� - _-_--_-__-_--....._...__..-.,�._._--..�_ � �-I - - - { _ -{ _ _Z _ _ - - , � REFLECTED CEILING L cor , ` \ SCALE: 1!4" = 1' `o �� GREEN PEBBLES ' 7 FLOOR ' L .- RECEPTION CO 'TER WILL HAVE A SEC TI 36" WIDE (MIN.) AND NCS MORE THAN 36" IN HEIG 14'-2 112" BENCH r SEAT El 0 -F E 7,1 EXISTING .,I H FIRE 9 RATED WAt\ CICI �l[l `P 4'-8" 6'-6" l 0 ElJ� ASTAINED CONCRETE FLOOR _ PL�UMBIN S7l1Ei OUT &CAPPED l - _- -- 'FOR FUTURE USE ONLY �� II II x x x x 7CTX 1 I x^}- % I I f II 3534 , I 20 4'-6" 6'-8" I _ FLOOR"li"'LAN X SCALE 1/4" = V GLASS MOSAIC PANEL Th X 20' LONG CROSS SECTION A,13 SCALE 1/4" = 1' WP BALL BLVD ~` Q m t!G`F:TN w U oPARKING LOT KOI NAIL.. o SPA #2025 WORLD MARKET FACTORY CARD IRGUI ' LINENS & THING ITY TARGET GREENWAY SITE PLAN NTS -8"D CAP WITH FLAPPER PEN RATE REAR WALL LEGEND --_I-"._EDI AP WITH FLAPPER NO SCREEN PENETRATE REAR WALL 2'X2' AIR DIFFUSER LIGHT SWITCH (^� THERMOS -FAT 2'X2' AC INTAKE AIR :(�) OUTLET II 24,26,28 l _o"v / EXISTI O BREAKROOM g\ 'OFFICE 7 ADA RESTRQOM 8' 0" 8'-0"LLI I� " 3'-0" T-0" 3'4" ` 12 6" F7 ELECTI PANEL \Jr I 4'-0", T-0" 3'-0" tA 1 q WAX ROOM 10 FACIAL OOM STORAGE _ 30,3P 16,18 ,tet 4" DRYER VENT EXHAUST FAN lr:jl GROAN 4TR53 309 CFM MIN. 44 80'_0"g 2. SERVICE COUNTER WILL HAVE A SECTION OF 34" MAX. HIGH 19 21 23 25 27 GFI OU FLET (10TYP TERMINATE BY A 6" END CAP WITH DAMPER 4. EXIST RESTROOM EXHAUST FAN X X 5. ALL EXIT AND EMERGENCY LIGHTING ON THE SAME X X DO CIRCUIT WITH BATTERY BACK UP 6. EXIST FIRE SPRINKLER SYSTEM TO BE ADJUSTED TO NEW SPACE LAY OUT 7.2 COATS OF SEMI -GLOSS PAINT AT TENANT CHOICE OF COLOR. EXISTING 1 F FIR, E RATED WALL` l �J 4'-8" � 4'-8" 4'-8" 4'-8" 4'-8" 4'-8" BENCH SEAT-- DRINKING'BQI'TLE — W/ DISPOSAL CUA X FUTURE WATER FIXTURE - - -_ -' -" - �- - - - 9, 0„ STAIN GONG. / COLOR DEVIDED LINE GREEN PEBBLES ' 7 FLOOR ' L .- RECEPTION CO 'TER WILL HAVE A SEC TI 36" WIDE (MIN.) AND NCS MORE THAN 36" IN HEIG 14'-2 112" BENCH r SEAT El 0 -F E 7,1 EXISTING .,I H FIRE 9 RATED WAt\ CICI �l[l `P 4'-8" 6'-6" l 0 ElJ� ASTAINED CONCRETE FLOOR _ PL�UMBIN S7l1Ei OUT &CAPPED l - _- -- 'FOR FUTURE USE ONLY �� II II x x x x 7CTX 1 I x^}- % I I f II 3534 , I 20 4'-6" 6'-8" I _ FLOOR"li"'LAN X SCALE 1/4" = V GLASS MOSAIC PANEL Th X 20' LONG CROSS SECTION A,13 SCALE 1/4" = 1' WP BALL BLVD ~` Q m t!G`F:TN w U oPARKING LOT KOI NAIL.. o SPA #2025 WORLD MARKET FACTORY CARD IRGUI ' LINENS & THING ITY TARGET GREENWAY SITE PLAN NTS -8"D CAP WITH FLAPPER PEN RATE REAR WALL LEGEND --_I-"._EDI AP WITH FLAPPER NO SCREEN PENETRATE REAR WALL 2'X2' AIR DIFFUSER LIGHT SWITCH (^� THERMOS -FAT 2'X2' AC INTAKE AIR :(�) OUTLET II 24,26,28 l _o"v / EXISTI O BREAKROOM g\ 'OFFICE 7 ADA RESTRQOM 8' 0" 8'-0"LLI I� " 3'-0" T-0" 3'4" ` 12 6" F7 ELECTI PANEL \Jr I 4'-0", T-0" 3'-0" tA 1 q WAX ROOM 10 FACIAL OOM STORAGE _ 30,3P 16,18 ,tet 4" DRYER VENT 2X4 FLUORESCENT LIGHT 10 MANICURE STATION Y O J d, J PERMIT INFORMATION TOTAL AREA: 1460 SF 1 STORY BUILDING TYPE IV UNPROTECTED SPRINKLER SCALE 1/4" = 1' APPLICABLE CODES: 2001 FLA. BLDG. CODE 2001 FLA. PLUM. CODE 2001 FLA. MECH. CODE 2001 FLA. FIRE PREV. CODE 2002 NAIL. ELEC. CODE 2000 NFPA 101 LIFE SAFTY CODE 2001 FLA. ACCESSIBILITY CODE FEB EXHAUST FAN lr:jl GROAN 4TR53 309 CFM MIN. 44 TELEPHONE JACK 2X4 FLUORESCENT LIGHT 10 MANICURE STATION Y O J d, J PERMIT INFORMATION TOTAL AREA: 1460 SF 1 STORY BUILDING TYPE IV UNPROTECTED SPRINKLER SCALE 1/4" = 1' APPLICABLE CODES: 2001 FLA. BLDG. CODE 2001 FLA. PLUM. CODE 2001 FLA. MECH. CODE 2001 FLA. FIRE PREV. CODE 2002 NAIL. ELEC. CODE 2000 NFPA 101 LIFE SAFTY CODE 2001 FLA. ACCESSIBILITY CODE FEB PEDICURE STATION ELECTRICAL 1, MAIN OVERCURRENT PROTECTION: 2U0 AMPS 2. NUMBER OF SERVISE DISCONNECTS: ONE FOR SEVICE , ONE FOR ROOF TOP UNIT 3. VOLTAGE OF THE SYSTEM: '120/208V 3 PHASE/ 4 WIRE 4. PHASE OF THE SYSTEM: 3 PHASES 4 WIRE/ ONE #6 GREEN 5. LOAD DESCRIPTIONS: TOTAL DEMAND 131.92 KVA (SEE ATTACHED CACULATION FORM) 6. BRANCH CIRCUIT AND EQUIP. REQUIRED: 16 BRANCH CIRCUITS (NEW) 7. CONDUCTOR SIZES: #12 AWG THHN AND #10 AWG THHN 8. CONDUCTOR TYPE : ALL CU (COPPER) 9. CONDUIT SIZES AND TYPE: 1/2 & 3/4 EMT. INTERIOR FINISH: A. PAINTING: BEHR PRODUCT SEMI GLOSS PAINT, FLASH POINT 214 F MECHANICAL: 1. THIS IS A EXISTING A/C SYSTEM ROOFTOP UNIT: RTU 2 CARRIER 4 TONS, '1600 CFM, MAKE UP AIR 50% OR 800 CFM DUCT: 14"X14", 14"X12", 12"X12" FIBERGLASS DUCT BOARD GRILL: 10" COLLAR 2. GFM OF OUTDOOR AIR PER TABLE 403.3:(25 PERSON PER 1000 SF 25 OUTSIDE AIR CFM PER PERSON MAX. NO. OF PERSON: 38 PERSON MIN. OUTSIDE AIR REQUIRED: 38 X25 CFM/PERSON = 950 CFM 3. CFM OF EXHAUST FAN: EXHAUST AIR : 746 CFM 4 ► 4 M IL ENTERPRISES INC DISiGn & CORITR T'®n 1280 PRINCE CT. LAKE MARY, FL 32746 (407) 805-0809 FAX: 407-805-8948 CGC 058578 Consultants HURRICANE ENGINEERING (407) -174-9003 FAX (407) 774-6477 P.O. BOX 161613 ALTAMONTE SPFlrGS, iL'IlK THOMAS 4. ANDERSON PE9 47819 Seal/Signature AMIk W F-- Z ® V. Q W J ti W 0 c JUL. )IIID.,. F_ O W F_ �ew J LL Q o � z �z c)� W � 1— vJ OWNER: 407-383-6163 CONSTRUTION DOCUMENTS PROPOSAL FLOOR PLAN ELECTRICAL PLAN Sheet Title DATE: 1/16/05 DRAWN BY: DVH REVISED: 2/15/05 REVISED: REVISED: REVISED: REVISED: REVISED: REVISED: Sheet No. Al GENERAL NOTES: FIRE SPRINKLER 1. MAKE UP AIR FOR EXHAUST FANS: OUTSIDE AIR DAMPERS AT RTU C PENDULAR LIGHT TO BE ADJUSTED 2. SERVICE COUNTER WILL HAVE A SECTION OF 34" MAX. HIGH 30" MIN. WIDE. 3. EXHAUST AIR DUCTS TO BE 6" GAVANIZED SHEET d r' EMERGENCY LIGHT METAL, PENETRATE REAR EXTERIOR WALL, TERMINATE BY A 6" END CAP WITH DAMPER 4. EXIST RESTROOM EXHAUST FAN X X 5. ALL EXIT AND EMERGENCY LIGHTING ON THE SAME X X DO CIRCUIT WITH BATTERY BACK UP 6. EXIST FIRE SPRINKLER SYSTEM TO BE ADJUSTED TO NEW SPACE LAY OUT 7.2 COATS OF SEMI -GLOSS PAINT AT TENANT CHOICE OF COLOR. PEDICURE STATION ELECTRICAL 1, MAIN OVERCURRENT PROTECTION: 2U0 AMPS 2. NUMBER OF SERVISE DISCONNECTS: ONE FOR SEVICE , ONE FOR ROOF TOP UNIT 3. VOLTAGE OF THE SYSTEM: '120/208V 3 PHASE/ 4 WIRE 4. PHASE OF THE SYSTEM: 3 PHASES 4 WIRE/ ONE #6 GREEN 5. LOAD DESCRIPTIONS: TOTAL DEMAND 131.92 KVA (SEE ATTACHED CACULATION FORM) 6. BRANCH CIRCUIT AND EQUIP. REQUIRED: 16 BRANCH CIRCUITS (NEW) 7. CONDUCTOR SIZES: #12 AWG THHN AND #10 AWG THHN 8. CONDUCTOR TYPE : ALL CU (COPPER) 9. CONDUIT SIZES AND TYPE: 1/2 & 3/4 EMT. INTERIOR FINISH: A. PAINTING: BEHR PRODUCT SEMI GLOSS PAINT, FLASH POINT 214 F MECHANICAL: 1. THIS IS A EXISTING A/C SYSTEM ROOFTOP UNIT: RTU 2 CARRIER 4 TONS, '1600 CFM, MAKE UP AIR 50% OR 800 CFM DUCT: 14"X14", 14"X12", 12"X12" FIBERGLASS DUCT BOARD GRILL: 10" COLLAR 2. GFM OF OUTDOOR AIR PER TABLE 403.3:(25 PERSON PER 1000 SF 25 OUTSIDE AIR CFM PER PERSON MAX. NO. OF PERSON: 38 PERSON MIN. OUTSIDE AIR REQUIRED: 38 X25 CFM/PERSON = 950 CFM 3. CFM OF EXHAUST FAN: EXHAUST AIR : 746 CFM 4 ► 4 M IL ENTERPRISES INC DISiGn & CORITR T'®n 1280 PRINCE CT. LAKE MARY, FL 32746 (407) 805-0809 FAX: 407-805-8948 CGC 058578 Consultants HURRICANE ENGINEERING (407) -174-9003 FAX (407) 774-6477 P.O. BOX 161613 ALTAMONTE SPFlrGS, iL'IlK THOMAS 4. ANDERSON PE9 47819 Seal/Signature AMIk W F-- Z ® V. Q W J ti W 0 c JUL. )IIID.,. F_ O W F_ �ew J LL Q o � z �z c)� W � 1— vJ OWNER: 407-383-6163 CONSTRUTION DOCUMENTS PROPOSAL FLOOR PLAN ELECTRICAL PLAN Sheet Title DATE: 1/16/05 DRAWN BY: DVH REVISED: 2/15/05 REVISED: REVISED: REVISED: REVISED: REVISED: REVISED: Sheet No. Al 120/208 SURFACE BUS KVA V 3 PH. 4W MOUNTED LOAD WIRE GND ELECTRICAL 10,000 AIC COND AMPS PANEL (EXISTING) (INTERGRATED) BUS KVA AMPSCOND TOTAL CONN. KVA GND WIRE SQUARE D MAIN LUGS 200 A MAIN BREAKER NIA LOAD BUS KVA A B C 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 A B C 2 4 6 8 10 12 40 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 A B C 1.65LIGHTING 0 1 0 #12 #12 1/2" 20 20 1/2" #12 #12 SPARE J N 1.60 n_o LIGHTING #12 #12 1/2" 20 20 1/2" #12 #121 EMERG. NIGHT LIGHT 1.2 W 1.501 WINDOW SHOW RECEPTACLE #12 #12 1/2" 20 20 1/2" 912 #12 MANICURE RECEPT NEW 1.5 75 RECEPTACLE #12 #12 1/2" 20 20 1/2" #12 #12 RECEPTACLE .75 .75 RECEPTACLE #12 412 1/2" 20 20 1/2" #12 #12 RECEPTACLE .75 .60 EF1 #12 #12 1/2"20 TENANT SIGN 1.5 4.6 RTU w/ 12 KW 3/4" #10 #6 90 20 1/2" #12 #12 EXHAUST FAN (NEW) 1.2 4.6 4.6 30 3/4" #12 #10 WATERHEATER (NEW) 2 2 9 FOOT 1 (NEW) #12 #12 1/2" 20 20 1/2" #12 #12 MANICURE RECEPT NEW 1.5 J FOOT SPA 2 (NEW) #12 #12 1/2" 20 20 1/2" #12 #12 PENDULAR LIGHTS (NEW) .5 9 FOOT SPA 3 (NEW) 12 #12 1/2" 20 30 3/4" #12 #10 TANNING (NEW) 2 2 .9 FOOT SPA 4 (NEW) #12 #12 1/2" 20 .9 FOOT SPA 5 (NEW) #12 #12 1/2" 20 2 .9 FOOT SPA 6 (NEW) 12 1/2" 20 30 3/4" #12 #10 WASHER & DRYER (NEW) 1.2 9 FOOT SPA 7 (NEW) 2 1/2" 20 1 2 .9 FOOT SPA 8 (NEW) #12 912 1/2" 20 20 1/2" #12 #12 FOOT SPA 10 (NEW) 9 9 FOOT SPA 9 NEW #12 #12 1/2" 20 _ TOTAL KVA PHASE A: 16.40 MAX PHASE CONN. KVA 16.70 TOTAL KVA PHASE B: 16.70 8.19 TOTAL KVA PHASE C: 16.4 10 1 CONNECT LOAD: 49.50 KVA 137.50 AMP TOTAL CONN. KVA = 49.55 TOTAL DEMAND KVA = 47.49 TOTAL DEMAND AMP. 47.49X-1000: (208X1.73) = 131.924AMP, NEW WALLS: CONSTRUCTED BY METAL STUD 25 GRADE 24" O.C. COVER BOTH SIDES WITH 1/2 GYPSUM BOARDS PAINTED, VERIFY COLOR W/ OWNER WALLS ARE LATERALLY SUPPORTED BY INTERSECTING WALLS ELECTRICAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE W/ THE (NEC) NATIONAL ELECTRICAL LOCAL & STATE CODES 2. CONTRACTOR SHALL SECURE ALL PERMIT 3. ELECT. DRAWINGS ARE CONSIDERED DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT ONLY 4. GROUND CONDUCTORS SHALL BE INSTALLED IN ALL FEEDERS AND BRANCH CIRCUIT CONDUITS. ALL EQUIPMENTS GROUND WIRES SHALL BE COPPER AND SIZE AS PER NEC ART 250-95 ELEC. HOT WATER HEATER 220V 30 AMP, PEDICURE CHAIRS TO BE GRAVITY DRAINED WALL 53" CONN. LOAD D.F CALC DEMAND KVA KVA LIGHTING 6.55 1.25 8.19 RECEP 1 st 10 KVA 10 1 10 RECEP ABOVE 10 KVA 5 0.5 2.5 MOTORS 0 1.25 0 EQUIMENT 27.10 1 27.10 APPLIANCE 0 0.80 00 SPARE/SPACE 0 1 0 TOTAL 49.50 47.49 VAL) 3/4" SAFE WASTE TC FLOOR DRAIN 1" DRAIN TO FLOOR DRAlt 11/2" El COLD WATER SUPPLY CHECK VALVE (TYP) y� Ooh,. �Y HOT WATER -ST-12 AMTROL THERMAL EXPANSION TANK DRAIN VALVE WATER BEATER PIPING DETAIL NO SCALE Electrical and Plumbing requirements: Power source : 120 v AC/ 10.6 amp 60 Hz, 12 volt DC with Ground Fault Interupter (GFI) Class A type Electrical wiring, component and connections must comply with local nodes. Water source: 1/2" fitting hot and cold. Normal water pressure of 30-125 PSI is required to correctly fill the tub to proper levels. brain source : 11/2" drain. Drain connection should meet local plumbing codes using 1-1/2" schedule 40 drain pipe and appropriate drain traps. 36" 18" -24" - 50" (VERIFY WITH OWNER) SAFETY PAN LIGHTING: RECEPTACLE: 4.55 1.5 x 4 = 6.0 2.0 LIGHT, SIGN ,9X10 = 9.0 SPA 1.2 X 2 = 2.4 DRYER 6.55 X 1.25 DF = 8.19 KVA ---- -------------- - 17.4 10.00 X 100% = 10.00 7.4 x.5 = 3.7 EQUIPMENT: 4.6 x3 = 13.8 RTU 4 WH .60 EF1 1.2 EF2 6.0 TAN 25.6 SHEET METAL EXHAUST DUCT I EXHAUST FAN HANGINGSTEEL ARMSTRONG CEILING HANGER WIRE BRACKET (ADJUSTABLE) 12 GAGE EXHAUST FAN TYPICAL CEILING CABINET EXHAUST FAN WITH BACK DRAFT DAMPER, LOW NOISE -- _--_ 013 LEVEL AND NO VIBRATION DRAWING FOR REFERENCE ONLY TYPE OF PEDICURE CHAIR TO VERIFY WITH THE TENANT. 17" I -- I TC-ENTER AT �- 29" HOT 6" HOT WATER SUPPLY AND DRAIN LINES SHALL BE FULLY INSULATED OR COVERED WITH A REMOVABLE, NON-METALLIC BAFFLE WHEN HOT WATER EXCEEDS 120 DEGREE F. EXISTING STEEL TRUSS REAR WALL CEILING HANGER WIRE 12 GAGE 1"X22 GUAGE BAND SPACING NOT OVER 5' 6" ALUM. END CAP L WI"fH FLAP / 6" GAV. DUCT CEILING MOUNTED CABINET EXHAUST FAN SECTION A -A SYSTEM No W -L-1085 UL ASSEMBLY DESIGN FOR THROUGH PENETRATION FIRESTOP (FOR SLEEVES PIPE OR CONDUIT PENETRATING FRAME WALL) Through - Penetration Firestop System Guide Information System No. W -L-1085 November 24, 1999 F rating ? 1 and 2 Hr. (see Item 1 B) T rating ? 0 Hr L Rating At Ambient 7 Less Than 1 CFM/Sq Ft L Rating At 400 F 7 4 CFM/Sq Ft 1. Wall Assembly The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wail and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs Wall framing may consist of either wood studs or steel channel studs. Wood to consist of nam 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board" 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening Is 13-1/4 in. Diam of circular opening cut through gypsum wallboard on each side of wall assembly to be min 1/4 in. to max 1/2 in, larger than outside diam of through penetrant (Item 2). The hourly F Rating of the firestop system is equal to the hourly fire rating of the wail assembly in which it is installed. 2. Through Penentrants One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The annular space between the through-penentrant and the periphery of the opening shall be min o in. to max 1/4 in. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe Nom 12 in. diam (or smaller) cost or ductile iron pipe. C. Conduit Nom 6 in. diam (or smaller) steel electrical metallic tubing or steel conduit. D. Copper Tubing Nom 6 in diam (or smaller) Type L (or heavier) copper pipe. 3. Fill, Void or Cavity Material* 7 Sealant Fill material to be forced into the annulus to maximum extent possible. Additional fill material to be installed such that a min 1/2 in. crown is formed around the penetrating item and lapping 1/4 in. beyond the periphery of the opening. HILTI CONTSTRUCTION CHEMICALS, DIV OF HILTI INC ? FS -One Sealant "Bearing the UL Classification Marking 8" KNEE CLEARANCE DASHED LINE DENOTES MAX. SIZE OF REMOVABLE, NON-METALLIC BAFFLE SHADED AREA DENOTES KNEE AND TOE SPACE REQUIRED AT ACCESSIBLE LAVATORY Z� -� CEILING EXHAUST FAN - 1/2" CW, HW TO PED. STATIONS HAND SINK L )_ 1 '-W', V-6' LAVATORY LOCATION FLOOR MOUNTED OR WALL MOUNTED WATERCLOSET FRONT VIEW .A1-).4 TOILETfROOM ELEVATION CLEARANCES BASED ON 2001 EDITION FLORIDA ACCESSIBILITY CODE NOTES: 1. USE #7X7/16" PAN HEAD TYPE "S" FRAMING SCREW FOR STEEL STUD TO STEEL TRACT. 2. USE #6X1-1/4" TYPE "S" DRYWALL SCREWS TO STEEL FRAMING. 3. METAL MEMBERS TO BE I ACCORDANCE r L.E WITH THE AISI SPECIFICATIONS FOR THE DESIGN OF COLD FORMED STRUCTURED MEMBER, LATEST EDITION. 4. METAL MEMBERS TO BE IN ACCORDANCE WITH ASTM C645 STANDARD SPECIFICATIONS FOR NONSTRUCTURAL STEEL FRAMING MEMBERS 2000 BOTTOM SIDE VIEW MAX 8'-0" -`- 0'-0" ------ 2X4 CEILING TILE RUNNER 1/2" GYPSUM BOARD METAL STUD 25 GAGE 24" O.C. COVER BOTH SIDES WITH 1/2 GYPSUM BOARDS 8' WAIL PAINTED, VERIFY COLOR W/ OWNER WALLS ARE LATERALLY SUPPORTED BY INTERSECTING WALLS 3/16"X 1-1/4" MASANARY SCREWS OR POWDER ACTUATED SCREWS 1f,, O.C. L� CONC. SLAB TYPICAL NON BEARING INTERIOR PARTITION WALL 3/4" CW 3/4" HW FROM EXISTING e SANITARY ISOMETRIC RISER NTS 3/4" BACK FLOW _-PREVENTER CHECK VALVE 3/4" CggW44 LAV 31 Com' ,�. 3/4" P&T RELIEFCONT. ® HW TO RUN OUTSIDE OR n314 ® 314 TO F.D. 50 G S L I DOUBLE EWH WG 1 112 SINK-� fil a � ,�•,.. 112' C Q I Iz PED. 6 - '10 NW 0 m PED. 5 TYP PED.4 °._.--.-A-*.. PED. 3°nf n ��I2' C� o HOT WATER n "1 I' " PED. 2 COLD WATER PEI). 1 UDO VENT 1 HMD ENTERPRISES INC IEsiGn & COMTRuCTI n 1280 PRINCE CT. LAKE MARY, FL 32746 (407) 8050809 FAX: 407805-8948 CGC 058578 Consultants HURRICANE ENGINEERING (407) 774-9003 FAX(407)774-a477 P.O. BOX 161613 ALTAMONTE SPRINGS, FL 32716 THOMAS 1 ANDERSON PE'i 47819 Seal/Signature 15" SIDEWALL GRAB BA[ 6' 36" MIN `12 11 - - �- - ---- IF= -- _--_ 013 _-cr---- _0 w WU 1 '-W', V-6' LAVATORY LOCATION FLOOR MOUNTED OR WALL MOUNTED WATERCLOSET FRONT VIEW .A1-).4 TOILETfROOM ELEVATION CLEARANCES BASED ON 2001 EDITION FLORIDA ACCESSIBILITY CODE NOTES: 1. USE #7X7/16" PAN HEAD TYPE "S" FRAMING SCREW FOR STEEL STUD TO STEEL TRACT. 2. USE #6X1-1/4" TYPE "S" DRYWALL SCREWS TO STEEL FRAMING. 3. METAL MEMBERS TO BE I ACCORDANCE r L.E WITH THE AISI SPECIFICATIONS FOR THE DESIGN OF COLD FORMED STRUCTURED MEMBER, LATEST EDITION. 4. METAL MEMBERS TO BE IN ACCORDANCE WITH ASTM C645 STANDARD SPECIFICATIONS FOR NONSTRUCTURAL STEEL FRAMING MEMBERS 2000 BOTTOM SIDE VIEW MAX 8'-0" -`- 0'-0" ------ 2X4 CEILING TILE RUNNER 1/2" GYPSUM BOARD METAL STUD 25 GAGE 24" O.C. COVER BOTH SIDES WITH 1/2 GYPSUM BOARDS 8' WAIL PAINTED, VERIFY COLOR W/ OWNER WALLS ARE LATERALLY SUPPORTED BY INTERSECTING WALLS 3/16"X 1-1/4" MASANARY SCREWS OR POWDER ACTUATED SCREWS 1f,, O.C. L� CONC. SLAB TYPICAL NON BEARING INTERIOR PARTITION WALL 3/4" CW 3/4" HW FROM EXISTING e SANITARY ISOMETRIC RISER NTS 3/4" BACK FLOW _-PREVENTER CHECK VALVE 3/4" CggW44 LAV 31 Com' ,�. 3/4" P&T RELIEFCONT. ® HW TO RUN OUTSIDE OR n314 ® 314 TO F.D. 50 G S L I DOUBLE EWH WG 1 112 SINK-� fil a � ,�•,.. 112' C Q I Iz PED. 6 - '10 NW 0 m PED. 5 TYP PED.4 °._.--.-A-*.. PED. 3°nf n ��I2' C� o HOT WATER n "1 I' " PED. 2 COLD WATER PEI). 1 UDO VENT 1 HMD ENTERPRISES INC IEsiGn & COMTRuCTI n 1280 PRINCE CT. LAKE MARY, FL 32746 (407) 8050809 FAX: 407805-8948 CGC 058578 Consultants HURRICANE ENGINEERING (407) 774-9003 FAX(407)774-a477 P.O. BOX 161613 ALTAMONTE SPRINGS, FL 32716 THOMAS 1 ANDERSON PE'i 47819 Seal/Signature OWNER: CONSTRUTION (DOCUMENTS DETAIL PLAN Sheet Title DATE: 1/16/05 DRAWN BY: DVH REVISED: REVISED: REVISED: REVISED: REVISED: REVISED: REVISED: Sheet No. A.Z W QW WU Uw � Z J N n_o m M F" W < U. � J m D a� = w LO oQ OWNER: CONSTRUTION (DOCUMENTS DETAIL PLAN Sheet Title DATE: 1/16/05 DRAWN BY: DVH REVISED: REVISED: REVISED: REVISED: REVISED: REVISED: REVISED: Sheet No. A.Z