HomeMy WebLinkAbout2111 WP Ball Blvd (fr sp) (a) (2)CITY OF SANFOIM PERMIT APPLICATION Permit # ; . p I / w .� S �r S?. Date: Job Address: _ 2 1 6e,, // /?h'-,(/, Description of Work: Historic District: U -v � Zoning:Value of Work: $ UU __�•__ Permit Type: Building Electrical Electrical: New Service – # of AMPS Mechanical: Residential Non -Residential Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets Occupancy Type: Residential Commercial Mechanical Plumbing Fire Sprinkler/Alarm Pool _ Addition/Alteration Change of Service Temporary Pole Replacement New (Duct Layout & Energy Calc. Required) # of Water & Sewer Lines # of Gas Litres Industrial Construction Type: # of Stories: # of Dwelling Units: Plumbing Repair – Residential or Couunercial Total Square Footage: Flood Zone: (FEMA form required for other than a) Parcel #: (Attach Proof of Ownership & Legal Descripfiiote) Owners Name & Address: Phone: _ Contractor Name & Address: �✓%`tr E!j ,. r� „ ;{�, State License Number. S CV LZ 6 (2 V 1 cl 4 7 Phone & Fax:!ixy Phone; J 1 E. r. Bonding Company:! _ Address: Mortgage Lender: Address: "a AN n 7 )f flrW Architect/Engineer: wt r • a Phone: Address: ASA , , . � 4, Fax: Application is hereby made to obtain a xv 9Y — pp y permit to do the wofk VP in1talja ion a��n�ic�tfd. [ cetttfy� that no work or installation has connnuu ed Bros to the issuance of a permit and that all work will be.performed to mect'stand�r PH a s regul ting con�tructl4 to this jurisdiction. I understand flat a mparate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POO S, FURNACESIBOILERS, HEATERS, TANKS, tuid AIR CONDITIONERS, etc. _OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laves, regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT iN Y OUF PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR Atd ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public 1,tc nds of this county, and there may be additional permits required from other governmental entities such as water management di ets, state agencies, rrt• f,,dctal agencies. Acceptance of permit is verification that I will notify the owner of the property of the require m 6i oIf Flo • a Lie t'La , FS 7 _ Signature of Owner/Agent Date Signature Con ctor/Agent Date Print Owner/Agent's Name P rinttractorr///Agent's Name n /-7/`b-.!5 Signature of Notary -State of Florida Date of Notary -State of Florida ' Date - - Owner/Agent is _ — Produced ID Personally Known to Me or Contractor/Agent is LCL Personally Known to Me or -124oduscvl FD ; a {i APPLICATION APPROVED BY: Btd� L.6 t/ Zoning: Utilities: FD• T. / l�• '°'�. (Initial & Date) (Initial & Date) (Initial & Date (lnthal &Date) Special Conditions: LINDA L. PHILLIPS Notary Public, State of Florida CS" My comm. exp. Sept. 29, 2006 � , Comm. No. DO 154192 Ir MPZ TER OVER W/RFz BACKFLOW PREVEN10I ALESS�E res r 1041 INCREASER 9 8" 2792' + WP WATER FLOW INFORMATI❑N STATIC 1 52 P.S.I. RESIDUAL ; 45 PSI FLOW : 2040 G.P.M. TEST TAKEN .JANUARY , 2004 FOR SITE PLAN SEE SHEET 2 OF 2 i U40 BK �, 19 �+ + w M WM--------Wm -------- WM_ 533,1 -------- �<EY PLAN NTS SITE DETAIL NTS 4'X2%2X2%2 i ELEC BE EAGLIA_.' FIR_17�.' PROTECTION I1\1C. 1205 CR 0 W1\1 PARK , I_ R CL -'L-ORIDA 34 78 WI1\1TER GARD-IZ�.71\V f 0 7 General Notes 1. A11 Pipe Locations are to be Field Measured Prior to Fabrication and Installation by Sprinkler Contractor. 2. All Dimensions Shown are Center to Center. 3. High Temperature Heads are to be Field Located Where Required. 4. All Pipes and Hangers are to be Installed per NFPA #13. 5. Hangers are to be U.L. Listed and F.M. Approved. S mbols Symbol Description 0 Hydraulic Reference Points Ela ec] Elev. Below Top of Steel C a-61 Elev. Above Finished Floor + OTOS 20-0> Elev. of Top of Steel Iio Ceiling Height --7,"- Denotes Hanger Location o Rise up or down J TYPICAL 1"- 4" E NO sc� 1 -- 3/8* All fhm t -- Riny t -- 3/8' fop Bea 4" VA BUILDINE S�CTI❑N NITS EDC DETAIL NTS WATER GAL 4' CHECK VALVE —� OUT TO FDC 1/2' BALL DRIP�I 18' - 48' AFF 1 1 LII o�� WET SYSTEM ,1 DRAIN/ TEST & DRAIN TEST 4' CHECK VALVE ❑L VALVE R SWITCH RISER DETAIL NTS Nurnber of S rinklers Total This Sheet ITotal This Job Syrnbol Description -0-241 VIKING M 3/4' 155" CHROME RECESS PENDENT Drawing F,P —1 Title Contract No. 04-55 PIANS REVIEWED F.E.E. Scale 1/4" = 1-0 CITY OF SANFORD 1/4/05 Approval By P " . 441 N LIT E S'F DESIGN I RETAIL STORE ORDINARY HAZARD GROUP II N .2/1500S.F. MAX HEAD SPACING 130 S.F. N _ PIPING ; 1"- 2" BLACK STEEL SCH - 40 cro` 1'/2 "-4" BLACK STEEL DYNA-F-LUW n A M C S M C U R T T S SC 6'- 8' BLACK S-TEEL SCH- .10 o FITTINGS ; 1"- 2° D.I. THREADED 8801 HUNTF RS I_AK� DRI_V� `L IY2'- 8" WELDED AND GROOVED U r 111 HANGERS ; 1"- 4" 3/8' T.B C. , 3/8" A.T.R. , RING SUITE 221 r Z 2 6"-8" 1/2" T B,C. , 1/2" A.T.R. , RING -PA TAMPA FLORIDA 3364 �� Un `b\ w SPACED PER NF 13 , 1999 ED. �, r CERTIFICATE # 37912 1 M Nurnber of S rinklers Total This Sheet ITotal This Job Syrnbol Description -0-241 VIKING M 3/4' 155" CHROME RECESS PENDENT Drawing F,P —1 Title Contract No. 04-55 Drawn By F.E.E. Scale 1/4" = 1-0 Date 1/4/05 Approval By Revisions: 10 Job: RETAIL SHOPS "D" V�i Date: 2111 W.P. BALL BOULEVARD, SANFORD , FLORIDA O Gorltractor: � YOUNG CON'T'RACTING CO., INC. r� 8215 ROSWELL ROAD r� ATLANTA , GEORGIA