Loading...
HomeMy WebLinkAbout2111 WP Ball Blvd (interior) (a):Cxt'crmit # Job Address: Description of Work: �`r Ilistoric District: Zoning: CITY OF SANFORD PER111T APPLICA1 ION Permit'l'ype. Buildings I _ Electrical Electrical: New Service —# of AMUS Mechanical: Residential Non -Residential Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets_ Occupancy Type: Residential Commercial Construction Type: X # of Stories: Date: Value of Work: `tel (L CJ Mechanical Plumbing Fire Sprinkler/Alarm Pool Addition/Alteration Change of Service "I'emporary Pole _ Replacement New (Duct Layout & Energy Calc. Re(juired) # of Water & Sewer Lines # of Gas Lines Plumbing Repair—Residential or Commercial J( Industrial I of ll Squ.0 c Foot tg�''' Z # of Dwelling Units: Flood Zone: -� (FLMA form required for other than X) 1 G 2 , 32- %'\ - 3o - 541, tDcm ^ ooze Parcel #: � ` `^3p �� + �DJO �� (Attach Proof of 011'nership & Legal Description) �O,rrrers Name & Address: JMAP SEl'+n,tl.)�o't'� (YA(Z.�ENKACk. W—C. t I S�tb �1�t c�m[3 �►UICE ZD/ �O�.� Iso . LOFI ,, M 3c"Io "BLIS �7 �O(45 " (oS-���6 14O UD Name & Address: �WKA-a �� �� iij.P1L�ILI �S)m 1e1`� UZIS P-ODSWIE U P-yAb I Ya 4ODS / -' G(7C. oS32 � [/� � 6 30�o SSttate. License Number, Phone & Fax:i-lo-S-a- Contact Person; HOWIAS, !'hone: 710" SZZ—CIZIID Bonding; Company: NIA fI(I Address: Mortgage Lender: N3 JA Address: Architect//Engineer:" PNIIa 1PS P�tIzT1.�EaS►t�� y Phone: ��'-��q��' IFjI (O Address: \mCe"y(ttl-.Q.°dlk-� � t1 -T (4 �/�tl'�J�OA �hA S�t��J7.�d I'ax` no" SI�' 131 AM ft ^n re. Application is hereby made to obtain a permit to do MMS v r inita(� tions ps'Ind c:� c c iif {hat vo.1 vork or installation has commenced prior to the issuance ofa permit and that all work will be perib med lope$t sta�ida� 7� f u(l I' s`r jb eoi sg • or in this jurisdiction. l understand that a separate Permit must be secured for ELECTRICAL WORK,, PU NIPIT, SU 1, W �L �'f�9 , F�RIy�AC^ O LERS, I I EATERS, 'FAN KS, and AIR CONDITIONERS, etc. �� } OWNER'S AFFIDAVIT: I certify that all of the tdtegoing information is accurate and I �t all work will;We; jq_�e in compliance with all applicable laws regulating construction and zoning. WARNING "l'O OW ,YOtltt FAILU� TP RYC,E RLI(J�-Fiu OI CUMb1JrNCENIENT MAY RESULT IN YOUR PAYING "TWICE FOR IMPROVEMENTS1f0 YOUR l'I t��l Lftf Y; -1F YOU NTEND TO OBTAIN FINANC A, C QNSULT WITH Y0t1R LENDER OR AN ATTORNEY BEFORE RECORDING YQUR f "I1C�01` COMMENCEMENT. , r It l• A NOTICE: In addition to the requirements of this;I I)il>there nr y a di�i a ri",ri f licableto this.pioperly that may be ILund in the public records of this coup 1- ty, and there may be additional permits;jy; u�r sf tram tl' r av rnni nEa li yrs cus water Ifla dement districts, state agencies, or federal agencies. y Acceptance ofpermmit is ver ieation that I will nijt t .the owner of t e property ofhe regmremt nts�d i lord3'�ien Law, FS "113. Sign d ue f Owner/Agent Date Signature of Contractor/Agent Date ZF,FFy-" P PF. r;od M ner/Agent's Na �e Print Contractor/Agent's Name " Z 'o Si„t r, of -State of Florida Date Signature of Notary -State of Florida Date NY S. FLANDERS Lary lie , -Cobb Cot�b County, Georgia My CornmissiVon Expires January 2.7, 2007 QwnQr/Agee is /� Personally Known to Me or Contractur/Agent is Personally Known to Me or _ Produced ID Produced ID APPLICATION APPROVED BY: Bldg: Csf� Loring `t, tiil Utiliticsa/�'� ' (Ini ial & Date) (utiuu Date) (Initial k, Date) (Imual Date) Special Conditions: .�,,, OWNER: NORTH AMERICAN PROPERTIES JEFF PAPE SIESMIC ZONE: REFER TO STRUCTURAL DRAWINGS 1080 HOLCOMB BRIDGE ROAD JOEL MABRY BLDG. 200 SUITE 150 TEL: (770) 643-6566 EDITION ROSWELL, GA 30075 FAX: (770) 643-9540 ARCHITECT: PHILLIPS PARTNERSHIP ROB FRENCH EDITION 9000 CENTRAL PARK WEST DWIGHT BAILEY EDITION SUITE 400 TEL: (770) 394-1616 ATLANTA, GA 30328 FAX: (770) 394-1314 CIVIL: KIMLEY-HORN ASSOCIATES JEFF BRITTAIN 3660 MAGUIRE BLVD. 2000 EDITION SUITE_ 200 TEL: (407) 898-1511 ORLANDO, FL 32803 FAX: (407) 898-4791 STRUCTURAL: HAINES GIPSON & ASSOCIATES RANDY GIPSON 1550 NORTH BROWN ROAD SUITE 100 TEL: (770) 491-7550 TUCKER, GA 30043 FAX: (770) 491-7750 MECHANICAL/ JORDAN & SKALA LYNN WITCHER PLUMBING- 5365 OAKBROOK PARKWAY JEREMY WAITS NORCROSS, GA 30093 TEL- (770) 447-5547 FAX- (770) 448-0262 ELECTRICAL: JORDAN & SKALA TONY OWEN 5365 OAKBROOK PARKWAY TEL: (770) 447-5547 NORCROSS, GA 30093 FAX: (770) 448-0262 LANDSCAPE SITE SOLUTIONS DAVID FLOYD ARCHITECT: 5064 ROSWELL ROAD MONIQUE LACASSE SUITE C-101 TEL: (404) 705-9411 ATLANTA, GA 30342 FAX: (404) 459-9412 GENERAL YOUNG CONTRACTING COMPANY RANDY THOMAS CONTRACTOR: 8215 ROSWELL ROAD TEL: (770) 522-9270 BUILDING 400 FAX: (770) 522-9273 ATLANTA, GA 30350 BUILDING CITY OF SANFORD DON FLORIAN DEPARTMENT: 300 N. PARK AVENUE SANFORD, FL 32772 TEL: (407) 330-5657 FIRE SANFORD FIRE DEPARTMENT TIM ROBLES DEPARTMENT: FIRE PREVENTION DIVISION P.O. BOX 1788 TEL: (407) 302-2520 SANFORD, FL 32771 FAX: (407) 302-2526 SITE THE BRIAR CORPORATION BOB HARRELL CONTRACTOR: PO BOX 470264 TEL: (407) 321-2773 LAKE MONROE, FL 32747 FAX SANFORD, FLORIDA NORTH AmMERICAN,P.ROPERTIES t Em LOCATION: CITY OF SANFORD SEMINOLE COUNTY, FLORIDA PROJECT ADDRESS: 2111 W.P. BALL BOULEBARD SANFORD, FLORIDA 32771 SITE ZONING: PD BUILDING SET BACKS: FRONT: 25'-0" REAR: 20'-0" SIDE: 10'-0" WIND SPEED: 110 MPH SIESMIC ZONE: REFER TO STRUCTURAL DRAWINGS APPLICABLE CODES: FLORIDA BUILDING CODE (FBC) 2001 EDITION LIFE SAFETY CODE (NFPA 101) 2000 EDITION NATIONAL ELECTRIC CODE (NEC) 2002 EDITION FLORIDA BUILDING CODE - GAS VOLUME (IGV) 2000 EDITION FLORIDA BUILDING CODE - MECHANICAL. VOLUME (IMV) .2000 EDITION FLORIDA BUILDING CODE - PLUMBING VOLUME (IPV) 2000 EDITION OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: ALLOWABLE HEIGHT: ACTUAL HEIGHT: ALLOWABLE AREA: OCCUPANT SEPARATION: TENANT SEPARATION: EXITS REQUIRED: EXITS PROVIDED: TRAVEL DISTANCE: SPRINKL ERED: MERCANTILE TYPE IV UNPROTECTED SPRINKLERED 2 STORIES - 55' ONE STORY - VARIES (35'-0" MAX.) UNLIMITED (FBC 503.4.1) N/A 1 HOUR 2 HOUR 2 HOUR 75'-0" MAX. VICINITY 1 Satnt johns River I_ST,''te f, A;ror rai'ir s 8 `r 02004 ivUo0u9sbxsm. Inc.: 020C14 NA 11.0 FACE OF STRUCTURE CENTERLINE OF COLUMN ® 02� NOTE TAG REFERENCING GENERAL NOTES ON PLANS DOOR NUMBER, SEE DOOR SCHEDULE 3 ELEVATION MARK A-4.1 (�4 A-6.2 ENLARGED PLAN DETAIL MARK SECTION MARK A-5.4 SIM'- SIMILAR 'OH'- OPPOSITE HAND G E N E R A` N UO"' T E S 1. GENERAL CONTRACTOR SHALL FIELD VERIFY SURVEY LOCATION AND ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE TENANT (IF APPLICABLE) AND ARCHITECT, 2. THE GENERAL CONTRACTOR SHALL OBTAIN PERMITS, APPROVALS, INSPECTIONS, CERTIFICATE FOR COMPLIANCE AND CERTIFICATE OF OCCUPANCY AS REQUIRED. 3. GENERAL CONTRACTOR SHALL CHECK IN WITH AND COORDINATE ALL WORK WITH THE LANDLORD'S PROJECT PERSONNEL. 4. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHT, AND TELEPHONE IN ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. GENERAL CONTRACTOR SHALL REMOVE ALL THESE ITEMS AT THE COMPLETION OF WORK OR AS REQUIRED. 5. GENERAL CONTRACTOR SHALL MAINTAIN ON SITE AT ALL TIMES, ALL APPROVED DRAWINGS INCLUDING ALL REVISIONS AND ADDENDA. 6. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK IN A NEAT AND PROFESSIONAL MANNER. 3t7:7x.Y� CALCULATIO'NS 1(. x 1 10 .1 1 , , I — ", -.010 1laimm- IL ARCHITECTURAL SQ.. FT. PER OCCUPANT A-0.1 USE AREA (S.F.) PERSON LOAD A-1.1 TOTAL OCCUPANCY 2,428 30 81 MECHANICAL M-1.•1 UNITS OF EGRESS REQUIRED (0.20"x81) 16.21N. (321N. MIN.) MEANS OF EGRESS AT FRONT (PROVIDED) 68 INCHES MEANS OF EGRESS AT REAR (PROVIDED) 34 INCHES PLUMBING P-1,1 TOTAL UNITS OF EGRESS (PROVIDED) 102 INCHES ELECTRICAL E-1.1 I 'm 4W. RE, , lo, Sanford Fire Prev Win Dive Oche: COVER SHEET FLOOR PLAN, DETAILS, & SPECS WHITE BOX FLOOR PLAN MECHANICAL WHITE BOX FLOOR PLAN PLUMBING WHITE BOX FLOOR PLAN ELECTRICAL DCT 2 r _� /' z— REVISION # 38 SUMMARY �m A. SHEET ADDED PHILLIPS P A R T N E R S H I P Architecture • Interior Design , Planning p'-& 770.394.1616 ` 770.394.1314 RE K J I ^ a ,1.Ci+GZ L a r p E F G i i C RD CONSULTANT SEAL REVISIONS # DATE DESCRIPTION 10/18/04 SHOPS WHITE BOX rtes Gctumsnt is 0 ?NFps Purtnerahip. PC and is =cri -d an Imtnoncnt of :crike and is solcil for uac with rsogoQ to ttse pro ca as irrScnted below. All rights reserved. ilea y.+o�rnsnt mv/ not :a reproduced without the prior .uftton consont of F%16pe Parinwrahip, PC. TaWIT SHOPS D 2111 W.P. BALL BOULEVARD PROD ECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT NORTH AMERICAN PROPERTIES NORTH Add=RICAU PROPERTIES - ATLANTA 1030 TOL COMB, BRIDGE ROAD BUILCING 200, surrE , 50 ROS'AfLL, 0.^.30075 TEL 970) :45.6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER 0208616 ISSUE DAT= 05/14/04 DRAWN WCHECKED BY JLS/DEB DRAY'/ING TITh COVER SHEET SHEET NUM3ER A A A Um �. .MI V1 z ADJACENT TENANT 1 WHITE BOX FLOOR PLAN A 1.1 SCALE: 118"=1'-0" NORTH 0 /-% LJ %J /"'\%.J lm 111 1 1 1®1 i1 I"U A I NORTH 2 REFLECTED CEILING PLAN A 1.1 SCALE: 118"44" 0 18"W x 30"H (2/CS) MIRROR CENTERED ABOVE LAVATORY - STAINLESS -- 2'X 4' ACOUSTICAL LAY -IN STEEL FRAME CEILING ZX 4' ACOUSTICAL LAY -IN (1 EXHAUST FAN VENTED - - -, 18"W x 30"H (21cs) MIRROR CEILING TO EXTERIOR WALL CENTERED ABOVE LAVATORY - STAINLESS STEEL FRAME N 1742" GRAB- BAR 1'-0, 36" GRAB N, s, BAR _J N! N! TOILET PAPERLAVATORY 12" X 12" ACCESS DISPENSER PANEL CLEARANCE V-6" BASE VINYL 3 RESTROOM ELEV. - SIDEWALL 4 RESTROOM ELEV. = PLUMBING WALL 6 RESTROOM ELEV. - SIDEWALL A 1.1 SCALE: 114"=1'-0" A_1 1 SCALE: 1/4"=1'-0" A-1.1 SCALE: 1/4"44" NOTE: DIMENSIONS ARE TO WALL FINISH U.N.O. HELVETICA MEDIUI WHITE VINYL ADH LETTERS 4" HIGH NOTE: EACH DOOR SHALL BE LABELED WITH RESPECTIVE SHOP NUMBERS (TYP. AT ALL REAR DOORS.) c^, 3' ' 6" 3 ---- SLOPE 10 TYP. CEILING PROFILE A 1.1 SCALE: N.T.S. 7 REAR DOOR DETAIL e FRONT DOOR DETAIL s NOT USED A 1,1 SCALE: 1/4"=1'-0" A_1 1 SCALE: 1/4"=1'-0" A 1.1 SCALE: 1/4"=1'-0" REFER TO DOOR SCHEDULE FOR TYPICAL DOOR & HARDWARE, SHEET RA -7.1 ,DRIIKINGII)INTAIN- SEE PLUMBING DRAWINGS GRAB BARS TO MEET ADA I%D HANICAP CODES �Vni Viv WTI iV A,IV WALL HUNG MIRROR, TYP ENLARGED RESTROOM PLAN A-1.1 SCALE: 1/4"=1'-0" WALL TYPES RESTROOM NOTES; 1. ALL TOILET FIXTURES AND MOUNTING HEIGHTS SHALL COMPLY WITH LOCAL HANDICAP CODES AND ADA. 2. USE SAME LAVATORY SPACING & TOILET SPACING FOR RESTROOMS WITH DIFFERENT CONFIGURATIONS. 3. PROVIDE 2x4 BLOCKING AT ALL GRAB BAR LOCATIONS. 4. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 5. RESTROOM WALLS TO EXTEND TO A MINIMUM HEIGHT OF 12'-6" ABOVE FINISHED FLOOR. EXTEND TO ROOF DECK WHERE REQUIRED. NOTE: DIMENSIONS ARE TO FACE OF STUD U.N.O. PROVIDE PAPER HOLDER & MIRROR FOR EACH TOILET ROOM B1 3-5/8", 25 GAUGE DRY WALL METAL STUDS AT 16"o.c. TO 6" ABOVE CLG, WITH 1 LAYER OF 5/8" GYP. BD. EACH SIDE, MOISTURE RESISTANT AT TOILET INTERIOR ONLY. E2 1" METAL FURRING CHANNELS Cu) 24" O.C. W/ 1" RIGID INSULATION (R-5 MIN) AND 1/2" GYP. BOARD OVER TILT -UP PANEL. B3 6',25 GAUGE METAL STUDS cr 16" O.C. WITH BATT INSULATION (R-11 MIN) AND (2) LAYERS OF 5/8" TYPE W GYP BOARD @ THE INTERIOR FACE. R1 ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8", 18 GAUGE DRY WALL METAL STUDS @ 16" 0.0 WITH BATT INSULATION (MIN. R-11) AND 5/8" TYPE'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK, MOISTURE RESISTANT @ TOILET INTERIOR ONLY. UL DESIGN NO. U465, R2 ONE-HOUR RATED PARTITION EXI-ENDED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8", 18 GAUGE DRY WALL METAL STUDS 12" O.0 WITH BATT INSULATION (MIN. R-11) AND 5/8" TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. UL DESIGN NO. U465, R3 ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE AND CONSTRUCT WITH 6", 25 GAUGE DRY WALL METAL STUDS AT 16" O.C. WITH BATT INSULATION AND 5/8", TYPE W (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK. MOISTURE RESISTANT @ TOILET INTERIOR ONLY. R3 TWO-HOUR RATED PARTITION EXTENED TO DECK ABOVE AND CONSTRUCT WITH 6", 25 GAUGE DRY WALL METAL STUDS AT WITH BA"fT INSULATION (MIN. R-11) AND (2) LAYERS OF 5/8" TYPE 'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK R4 TWO-HOUR RATED PARTITION EXTENED TO DECK ABOVE AND CONSTRUCT WITH 3 5/8", 18 GAUGE DRY WALL METAL STUDS AT 16" O.C. WITH BATT INSULATION (MIN. R-11) AND (2) LAYERS OF 5/8" TYPE'X' (FIRE CODE) GYPSUM BOARD BOTH SIDES, FIRE TAPED TO DECK FINISH SCHEDULE DOOR SCHEDULE KEY MATERIAL MANUFACTURER SPECIFICATIONS z W-1 GYPSUM BOARD - TAPED, FLUAIED, SANDED AND READY FOR PAINT - SIZE (W x H X T) U-2 GYPSUM BOARD TOLD,fI TAPED, FLOATED, SANDED AND READY FOR PAINT O.C. C^1 OWNIF L.K. G.C. ✓ IF NEW IS REQUIRED, PROVIDE: ✓ 3'-0" X T-0" TEMPERED GLASS, ALUM. ALUM- USED AT MAIN ENTRANCE ONLY. 01 CC -1 UNSEALED COWREIE MECHANISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. BROOM CLEAN STORE FRONT (SHELL SCOPE) �2ALUM. \� ✓ ✓ ✓ (2) T-0" X T-0" TEMPERED GLASS ALUM. USED AT MAIN ENTRANCE_ ONLY. CLOSER, MORTISED CYLINDER WITH INTERCHANGEABLE CORE COORDINATE WITH LOCKSET STORE FRONT MECHANISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. 0 (SHELL SCOPE) 0 v//✓ 1-1/2 PAIR HINGES, MUTES, PRIVACY, CLOSER, AND FLOOR STOP. T -0"x T-0" HOLLOW CORE WOOD TO BE USED AT RESTROOM AND J3✓J ACr-1 CEILINGTILE/GRID ARMSTRONG MINA BOARD CORTECA2x4CEILING 'rILE1730USERIES: WHIFE INTERIOR, LOCKSET W/ ADA LEVER GS -I EXPOSED 5TRUCTUKE NO FIN1311 3-0' X T-0" HOLLOW CORE METAL TO BE HOLLOW METAL ALUM. USED AT BACK OF THE STORE ONLY. NOTES: 1. ALL FLOORING IS TO BE INSTALLED ACCORDING TO MANUFACTURER'S WRITTEN PROCEDURES. 2. ALL NEW AND OR EXISTING SURFACES SHALL BE PREPARED AS REQUIRED TO RECEIVE NEW FINISHES. 3. CONTRACTOR TO PROVIDE TRANSITION STRIPS AT ALL CHANGES BETWEEN DIFFERENT FLOOR TYPES. 4. CONTRACTOR TO INSTALL ONLY'CUT' ACT. ALL OTHER ACT TO BE SUPPLIED AND STORED IN SPACE FOR INSTAL LArION BY'I ENAN'r. CONTRACTOR SHALL SUBMIT SAMPLES TO ARCHI TEC r AND RECEIVE WRI TTEN APPROVAL BEFORE INSTALLATION. DOOR SCHEDULE HARDWARE_ SCHEDULE PROVIUEDBY INSTALL DOOR FRAME REMARKS DESCRIPTION PROVIDED 13Y INS TALL O.C. - SIZE (W x H X T) MATERIAL MATERIAL TOLD,fI MARK O.C. C^1 OWNIF L.K. G.C. ✓ IF NEW IS REQUIRED, PROVIDE: ✓ 3'-0" X T-0" TEMPERED GLASS, ALUM. ALUM- USED AT MAIN ENTRANCE ONLY. 01 MECHANISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. STORE FRONT (SHELL SCOPE) �2ALUM. \� ✓ ✓ ✓ (2) T-0" X T-0" TEMPERED GLASS ALUM. USED AT MAIN ENTRANCE_ ONLY. CLOSER, MORTISED CYLINDER WITH INTERCHANGEABLE CORE COORDINATE WITH LOCKSET STORE FRONT MECHANISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. 0 (SHELL SCOPE) 0 v//✓ 1-1/2 PAIR HINGES, MUTES, PRIVACY, CLOSER, AND FLOOR STOP. T -0"x T-0" HOLLOW CORE WOOD TO BE USED AT RESTROOM AND J3✓J v �� INTERIOR, LOCKSET W/ ADA LEVER WOOD PAINTED OFFICE. 3-0' X T-0" HOLLOW CORE METAL TO BE HOLLOW METAL ALUM. USED AT BACK OF THE STORE ONLY. PAINTED TO BE PAINTED (SHELL SCOPE) HARDWARE_ SCHEDULE WHITE BOX CONSTRUCTION CRITERIA (SUBJECT TO MINOR REVISION, PLEASE REFERTO LANDLORD'S DRAWINGS) SHELL CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1, CONCRETE FLOOR SLAB MARKETPLACE AT TOWNE CENTER SHOPPING CENTER SANFORD, FL SHELL CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1. CONCRETE FLOOR SLAB A) 4" - 3,000 PSI CONCRETE, WIRE MESH, 6 MIL VAPOR BARRIER TURN DOWN SLAB AT FRONT WALL UNFILLED EXPANSION CONTROL JOINTS UNSEALED, EXPOSED CONCRETE (BROOM CLEAN) LAST 15' OF SLAB AT BACK OF SPACE TO BE LEFT UNPOURED 2. CONCRETE SIDEWALK A) 4" - 3,000 PSI CONCRETE NO WIRE MESH TOOLED JOINTS WITH 2" TROWEL 3. CONCRETE TILT PANEL - EXTERIOR WALLS (REAR AND SIDE WALLS OF BUILDING) WILL REMAIN AS EXPOSED CONCRETE FOR THE SHELL SPACES. 4. STOREFRONT B) ONE SINGLE DOOR UNLESS NOTED OTHERWISE ON THE LANDLORD'S DRAWINGS) BLACK ANODIZED ALUMINUM FINISH (OR COLOR, IF SPECIFIED IN THE LANDLORD'S DRAWINGS) 9'- 0" HIGH W/ A 2'-0" TRANSOM AT 10'-0" AFF, OR AS NOTED DOUBLE STOREFRONT DOORS, ONLY AS NOTED (SEE LANDLORD'S DRAWINGS) STOREFRONT DOOR WITH STANDARD HARDWARE AND CLOSURE. LOCK CYLINDER TO BE KEYABLE TO REAR DOOR. KEYED FOR MASTER KEY TO FRONT AND REAR DOOR 5, REAR DOORS C) ONE SINGLE, HOLLOW METAL DOOR, UNLESS NOTED OTHERWISE IN THE LANDLORD'S DRAWINGS. TX T H.M. DOOR AND FRAME, DRIP AND WEATHER-STRIP STANDARD HARDWARE (PER LOCAL CODE) WITH CLOSER. LOCK CYLINDER TO BE KEYABLE TO STOREFRONT DOOR. KEYED FOR MASTER KEYING (FRONT AND REAR DOOR) PAINT ON BOTH SIDES OF THE DOOR 6. FRONT WALL ABOVE THE STOREFRONT. D) TAPED AND PAINT READY TO 12'-6" AFF E) INSULATED WITH 3-1/2" BATT INSULATION.E ROOFING SHEET METAL 1. 45 MIL TPO SINGLE -PLY, WITH 60 MIL VERTICAL FLASHING AND R-15 RIGID INSULATION, OR PER CODE, 2. GUTTER AND DOWNSPOUTS - FIELD PAINTED, GALVANIZED (UNLESS NOTED OTHERWISE IN THE LANDLORD'S DRAWINGS). PL UMBING/FIRE PROTECTION 1. SANITARY SEWER LATERALS STUBBED AND CAPPED 5' AFF INSIDE THE SPACE (NO VENT). 2. DOMESTIC WATER LINE STUBBED INTO EACH SPACE (OVERHEAD). 3. FIRE PROTECTION F) SPRINKLER SYSTEM, COMPLETE PER CODE AND NFPA REQUIREMENTS FOR "SHELL". G) SPRINKLER HEADS TURNED TO AN UPRIGHT POSITION H) FIRE RISERS WILL BE PROVIDED AT A LOCATION WITHIN 011E SPACE FOR EACH BUILDING. 1) SPRINKLER DESIGN/DISTRIBUTION TO BE COMPLETED BY THE SPRINKLER SUBCONTRACTOR, SUPPLY LINES SHOULD BE LOCATED WITHIN THE STRUCTURAL JOISTS, EXCEPT AREAS WHERE THE STRUCTURAL DESIGN CAN NOT ACCOMMODATE THE SPRINKLER LINES. SPRINKLER SYSTEM DISTRIBUTION LINES TO BE INSTALLED AT 13'-0" A.F.F. OR ABOVE. HVAC 1. ROOFTOP, GAS-FIRED UNITS WITH CURBS APPROXIMATELY 1 -TON PER 350 SF (MAXIMUM SIZE PER UNIT - 6.25 -TONS). CONTROL WIRING DROPPED INTO THE SPACE. 2. GAS LINES ARE TO BE INSTALLED OUTSIDE OF THE SHOPS, THE LINES WILL BE SIZED TO SERVICE THE RTU UNITS, ONLY. THE LINES WILL BE INSTALLED FROM THE GAS METER LOCATION TO THE RTU UNITS (S). THE GAS LINES ARE NOT EXTENDED INTO THE SPACE OR SIZED TO ACCOMMODATE TENAJ'TT ITEMS. ELECTRICAL 1. CONDUIT FROM DISCONNECT FOR ELECTRICAL SERVICE, STUBBrED o ABO`IE FINISH FLOOR (CAPPED), ADJACENT TO REAR DOOR, FOR FUPJRE PAtI£L. LOCATION SIZED FOR 200 AMP SERVICE OR GREATER (SEE WIDL ORD'S DRAWINGS). 2. CONDUIT & PULL STRING FROM ANTICIPATED PANEL LOCAT1Ot'1 TO EXTERK)R MOUNTED J -BOX AT CANOPY FOR CANOPY SIGNAGE. 3. CONDUIT AND PULL STRING FROM ANTICIPATED PANEL LOCATIOI"1 TO DISCONNECT MOUNTED ON THE RTU (S) FOR EACH SPACE. 4. 1" TELEPHONE CONDUIT WITH PULL -STRING FROM CABINET TO SPACE, STUBBED 6" ABOVE FINISHED FLOOR. MARKETPLACE AT TOWNE CENTER SHOPPING CENTER SANFORD, FL WHITE BOX CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1. DEMISING WALLS J) ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE, CONSTRUCTED WITH 3-5/8", 18 GAUGE METAL STUDS AT 16" O.C. WITH 5/8" TYPE "X" (FIRE CODE) GYPSUM BOARD (ON TENANT'S SIDE OF THE WALL), FIRE TAPED TO DECK ABOVE. TAPE, SANDED AND PAINT READY TO 12-6" ABOVE FINISHED FLOOR (AFF). 6",25 GAUGE METAL STUDS AT 16" O.C. WITH 5/8" TYPE "X" (FIRE CODE) GYPSUM BOARD (ON TENANT'S SIDE OF THE WALL), FIRE TAPED TO DECK ABOVE. TAPE, SANDED AND PAINT READY TO 12'-6" ABOVE FINISHED FLOOR (AFF). 2. REAR WALL A) UNPAINTED/ EXPOSED CONCRETE TILT -UP PANELS W R-5 RIGID INSULATION AND 5/8" GYP. BOARD ON 1"Z FURRING CHANNELS, PAINT READY TO 12'-6" AFF (FIRE TAPED TO DECK ABOVE). B) TILT -UP PANELS WALLS IN TOILET ROOMS WILL BE COVERED WITH MOISTURE RESISTANT GYPSUM BOARD ON 1" Z FURRING CHANNELS WITH MINIMUM R-11 RIGID INSULATION, PAINT READY TO 8"6" AFF. 3. ACOUSTICAL CEILING A) 2'0"X4'0" STANDARD GRID SYSTEM, WITH 5/8" NON -DIRECTIONAL FISSURED, FIBERGLASS CEILING PANELS AT 12'-0" AFF TYPICAL AND 8'-0" AFF AT RESTROOM. B) LANDLORD TO INSTALL "CUT" CEILING TILES ONLY, ALL FULL 2X4 CEILING TILES WILL BE STOCKPILED IN SPACE FOR TENANT'S INSTALLATION. 4. TOILET ROOMS A) TO" X TO" PREHUNG HOLLOW CORE WOOD DOOR AND FRAME UNIT WITH LEVER HANDLE HARDWARE (PRIMER PAINT). B) UNSEALED EXPOSED CONCRETE FLOOR, BROOM CLEANED. C) WALL HUNG 18"X36" MIRRORS, WALL MOUNTED (HEIGHT PER CODE), ABOVE LAVATORY. D) ONE TOILET PAPER HOLDER MOUNTED 1'5" TO 17" AFF PER TOILET. E) GRAB BARS PER CODE. F) FLOOR MOUNTED, OVERHEAD BRACED, BAKED ENAMEL PARTITIONS, IF REQUIRED PER CODE. G) QUANTITY OF RESTROOMS/FIXTURES AS INDICATED ON LANDLORD'S DRAWINGS, H) TANK -TYPE HANDICAP ACCESSIBLE WATER CLOSETS. 1) WALL HUNG LAVATORIES WITH HANDICAP ACCESSIBLE FAUCET. PROVIDE STRAINER AND INSULATED PIPE GUARDS. J) ONE EXHAUST FAN, PER RESTROOM. K) ONE LIGHT SWITCH PER RESTROOM. L) ONE WALL MOUNTED FLUORESCENT FIXTURE. NOTE. ENLARGED RESTROOM DETAILS AND DRAWINGS ARE PROVIDED FOR GENERAL INFORMATION ONLY, ACTUAL RESTROOM CONFIGURATIONS AREAS SHOWN ON THE FLOOR PLANS FOR YOUR SPACE, PLUMBING/FIRE PROTECTION 1. WALL HUNG ELECTRIC WATER FOUNTAINS (AS INDICATED IN LANDLORD'S DRAWINGS AND/OR REQUIRED BY CODE FOR STANDARD RETAIL USE.) 2. MOP SINK PROVIDED, WHERE REQUIRED BY CODE. 3. 10 GAL. ELECTRIC WATER HEATER. HVAC 1. PROVIDE DISTRIBUTION FROM ROOF -TOP UNIT(S). A) NON -DIRECTIONAL DIFFUSERS B) ONE RETURN AIR GRILL, PER RTU C) REFER TO LANDLORD'S DRWINGS FOR STANDARD DUCTWORK DISTRIBUTION. 2. PROVIDE A STANDARD HEAT/COOL THERMOSTAT MOUNTED 5'0" AFF IN RETAIL SPACE. ELECTRICAL 1. PANEL AND SERVICE TO BE 120/208 VOLT, THREE (3) PHASE. K) 0- 999 SF 100 AMP PANEL, WITH CONDUIT FOR 200 AMP SERVICE L) 1,000 - 3,999 SF 200 AMP PANEL, WITH CONDUIT FOR 200 AMP SERVICE M) 4,000 - 5,999 SF 300 AMP PANEL, WITH CONDUIT FOR 400 AMP SERVICE N) 6,000 - 7,999 SF 400 AMP PANEL, WITH CONDUIT FOR 400 AMP SERVICE NOTE. WIRE MAYBE COPPER OR ALUMINUM 2. OUTLETS WALL MOUNTED DUPLEX OUTLETS AT 20'0" O.C. ALONG SIDE WALLS, 15.1'3' AFF ONE (1) DUPLEX OUTLET MOUNTED 4'6" AFF AT TELEPHONE: BOARD. ONE (1) GFI OUTLET IN EACH RESTROOM. 3. LIGHTING A) ONE (1) 2'0"X4'0" FOUR -TUBE LAY -IN FLUORESCENT FIXTURE - ONE (1) FIXTURE, PER 96 SF FOR 80% FOR THE SPACE AND ONE (1) FIXTURE PER 200 SF FOR THE REMAINING 20% OF THE SPACE. B) ONE (1) 24" FLUORESCENT TWO -LAMP LIGHT FIXTURE, WALL MOUNTED AT 6 - ABOVE ABOVE THE VANITY MIRROR IN EACH RESTROOM. C) EXIT LIGHT AT FRONT AND REAR DOORS AND WALL MOUNTED EMERGENCY LIGHTS, AS REQUIRED BY CODE (FOR THE STANDARD WHITE BOX FINISH). D) ONE (1) LIGHT SWITCH FOR EACH RESTROOM. 3. TELEPHONE PROVIDE'/" X 2'0" X 2'0" F.R.T. PLYWOOD BACKBOARD ON REAR WALL, AT TELEPHONE CONDUIT LOCATION. REVISION # 38 SUMMARY A. SHEET ADDED Architecture • Interior Design . Planning '`' 770.394.1616 1- 770.394.1314 r -T RE K J I I a E F C H C RD A 3 C D CONSULTANT SEAL REVISIONS 4 DATE DESCRIPTION A 10/18/04 SHOPS WHITE BOX Rus dccument Is Q Philrips Partnership. PC and is com;darcd on Instrument of Service and is soWy for use with rc. -&a to the project as indicated below. All rights reserved lz4 6vc=ent may not be reproduced without the pror .rrtten consent of Phillips Purtnership, PC. TEXANT t�* 2111 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER CLIENT NORTH AMERICAN PROPEM S NORTH AMERICAN PROPERTIES - ATLANTA 1430 HOLCO'dB BRIDGE ROAD BUILEECANG 2000, SUITE 150 ROS'PfELL, GA 30075 TEL (770);.45-8566 FAX (770) 643-9540 PHILLIPS JOB NUMBER -- 0208616 ISSUE DATE 05/14/04 DRAYIN a(/CHECKED BY ALE/DEB DRAWING TIP. -E FLOOR PI AN) DETAILS, ." & SPECS SHEET NUMBER 33 A Aml PROVIUEDBY INSTALL MARK BY DESCRIPTION OWNR L.K. O.C. ENTRY LOCK. REKEY AS REQUIRED BY TENANT. C^1 ✓ ✓ ✓ IF NEW IS REQUIRED, PROVIDE: CLOSER, MORTISED CYLINDER WITH INTERCHANGEABLE CORE COORDINATE WITH LOCKSET MECHANISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. ENTRY LOCK. REKEY AS REQUIRED BY TENANT. `� ✓ ✓ ✓ IF NEW IS REQUIRED, PROVIDE: \ J CLOSER, MORTISED CYLINDER WITH INTERCHANGEABLE CORE COORDINATE WITH LOCKSET MECHANISM. OPERATE FROM OUTSIDE BY KEY AND INSIDE BY LATCH. 0 v//✓ 1-1/2 PAIR HINGES, MUTES, PRIVACY, CLOSER, AND FLOOR STOP. PROVIDE BUTTS, PEEPHOLE, CLOSER, SILENCERS, HANDLE AT J3✓J v V// INTERIOR, LOCKSET W/ ADA LEVER WHITE BOX CONSTRUCTION CRITERIA (SUBJECT TO MINOR REVISION, PLEASE REFERTO LANDLORD'S DRAWINGS) SHELL CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1, CONCRETE FLOOR SLAB MARKETPLACE AT TOWNE CENTER SHOPPING CENTER SANFORD, FL SHELL CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1. CONCRETE FLOOR SLAB A) 4" - 3,000 PSI CONCRETE, WIRE MESH, 6 MIL VAPOR BARRIER TURN DOWN SLAB AT FRONT WALL UNFILLED EXPANSION CONTROL JOINTS UNSEALED, EXPOSED CONCRETE (BROOM CLEAN) LAST 15' OF SLAB AT BACK OF SPACE TO BE LEFT UNPOURED 2. CONCRETE SIDEWALK A) 4" - 3,000 PSI CONCRETE NO WIRE MESH TOOLED JOINTS WITH 2" TROWEL 3. CONCRETE TILT PANEL - EXTERIOR WALLS (REAR AND SIDE WALLS OF BUILDING) WILL REMAIN AS EXPOSED CONCRETE FOR THE SHELL SPACES. 4. STOREFRONT B) ONE SINGLE DOOR UNLESS NOTED OTHERWISE ON THE LANDLORD'S DRAWINGS) BLACK ANODIZED ALUMINUM FINISH (OR COLOR, IF SPECIFIED IN THE LANDLORD'S DRAWINGS) 9'- 0" HIGH W/ A 2'-0" TRANSOM AT 10'-0" AFF, OR AS NOTED DOUBLE STOREFRONT DOORS, ONLY AS NOTED (SEE LANDLORD'S DRAWINGS) STOREFRONT DOOR WITH STANDARD HARDWARE AND CLOSURE. LOCK CYLINDER TO BE KEYABLE TO REAR DOOR. KEYED FOR MASTER KEY TO FRONT AND REAR DOOR 5, REAR DOORS C) ONE SINGLE, HOLLOW METAL DOOR, UNLESS NOTED OTHERWISE IN THE LANDLORD'S DRAWINGS. TX T H.M. DOOR AND FRAME, DRIP AND WEATHER-STRIP STANDARD HARDWARE (PER LOCAL CODE) WITH CLOSER. LOCK CYLINDER TO BE KEYABLE TO STOREFRONT DOOR. KEYED FOR MASTER KEYING (FRONT AND REAR DOOR) PAINT ON BOTH SIDES OF THE DOOR 6. FRONT WALL ABOVE THE STOREFRONT. D) TAPED AND PAINT READY TO 12'-6" AFF E) INSULATED WITH 3-1/2" BATT INSULATION.E ROOFING SHEET METAL 1. 45 MIL TPO SINGLE -PLY, WITH 60 MIL VERTICAL FLASHING AND R-15 RIGID INSULATION, OR PER CODE, 2. GUTTER AND DOWNSPOUTS - FIELD PAINTED, GALVANIZED (UNLESS NOTED OTHERWISE IN THE LANDLORD'S DRAWINGS). PL UMBING/FIRE PROTECTION 1. SANITARY SEWER LATERALS STUBBED AND CAPPED 5' AFF INSIDE THE SPACE (NO VENT). 2. DOMESTIC WATER LINE STUBBED INTO EACH SPACE (OVERHEAD). 3. FIRE PROTECTION F) SPRINKLER SYSTEM, COMPLETE PER CODE AND NFPA REQUIREMENTS FOR "SHELL". G) SPRINKLER HEADS TURNED TO AN UPRIGHT POSITION H) FIRE RISERS WILL BE PROVIDED AT A LOCATION WITHIN 011E SPACE FOR EACH BUILDING. 1) SPRINKLER DESIGN/DISTRIBUTION TO BE COMPLETED BY THE SPRINKLER SUBCONTRACTOR, SUPPLY LINES SHOULD BE LOCATED WITHIN THE STRUCTURAL JOISTS, EXCEPT AREAS WHERE THE STRUCTURAL DESIGN CAN NOT ACCOMMODATE THE SPRINKLER LINES. SPRINKLER SYSTEM DISTRIBUTION LINES TO BE INSTALLED AT 13'-0" A.F.F. OR ABOVE. HVAC 1. ROOFTOP, GAS-FIRED UNITS WITH CURBS APPROXIMATELY 1 -TON PER 350 SF (MAXIMUM SIZE PER UNIT - 6.25 -TONS). CONTROL WIRING DROPPED INTO THE SPACE. 2. GAS LINES ARE TO BE INSTALLED OUTSIDE OF THE SHOPS, THE LINES WILL BE SIZED TO SERVICE THE RTU UNITS, ONLY. THE LINES WILL BE INSTALLED FROM THE GAS METER LOCATION TO THE RTU UNITS (S). THE GAS LINES ARE NOT EXTENDED INTO THE SPACE OR SIZED TO ACCOMMODATE TENAJ'TT ITEMS. ELECTRICAL 1. CONDUIT FROM DISCONNECT FOR ELECTRICAL SERVICE, STUBBrED o ABO`IE FINISH FLOOR (CAPPED), ADJACENT TO REAR DOOR, FOR FUPJRE PAtI£L. LOCATION SIZED FOR 200 AMP SERVICE OR GREATER (SEE WIDL ORD'S DRAWINGS). 2. CONDUIT & PULL STRING FROM ANTICIPATED PANEL LOCAT1Ot'1 TO EXTERK)R MOUNTED J -BOX AT CANOPY FOR CANOPY SIGNAGE. 3. CONDUIT AND PULL STRING FROM ANTICIPATED PANEL LOCATIOI"1 TO DISCONNECT MOUNTED ON THE RTU (S) FOR EACH SPACE. 4. 1" TELEPHONE CONDUIT WITH PULL -STRING FROM CABINET TO SPACE, STUBBED 6" ABOVE FINISHED FLOOR. MARKETPLACE AT TOWNE CENTER SHOPPING CENTER SANFORD, FL WHITE BOX CONSTRUCTION CRITERIA GENERAL CONSTRUCTION 1. DEMISING WALLS J) ONE-HOUR RATED PARTITION EXTENDED TO DECK ABOVE, CONSTRUCTED WITH 3-5/8", 18 GAUGE METAL STUDS AT 16" O.C. WITH 5/8" TYPE "X" (FIRE CODE) GYPSUM BOARD (ON TENANT'S SIDE OF THE WALL), FIRE TAPED TO DECK ABOVE. TAPE, SANDED AND PAINT READY TO 12-6" ABOVE FINISHED FLOOR (AFF). 6",25 GAUGE METAL STUDS AT 16" O.C. WITH 5/8" TYPE "X" (FIRE CODE) GYPSUM BOARD (ON TENANT'S SIDE OF THE WALL), FIRE TAPED TO DECK ABOVE. TAPE, SANDED AND PAINT READY TO 12'-6" ABOVE FINISHED FLOOR (AFF). 2. REAR WALL A) UNPAINTED/ EXPOSED CONCRETE TILT -UP PANELS W R-5 RIGID INSULATION AND 5/8" GYP. BOARD ON 1"Z FURRING CHANNELS, PAINT READY TO 12'-6" AFF (FIRE TAPED TO DECK ABOVE). B) TILT -UP PANELS WALLS IN TOILET ROOMS WILL BE COVERED WITH MOISTURE RESISTANT GYPSUM BOARD ON 1" Z FURRING CHANNELS WITH MINIMUM R-11 RIGID INSULATION, PAINT READY TO 8"6" AFF. 3. ACOUSTICAL CEILING A) 2'0"X4'0" STANDARD GRID SYSTEM, WITH 5/8" NON -DIRECTIONAL FISSURED, FIBERGLASS CEILING PANELS AT 12'-0" AFF TYPICAL AND 8'-0" AFF AT RESTROOM. B) LANDLORD TO INSTALL "CUT" CEILING TILES ONLY, ALL FULL 2X4 CEILING TILES WILL BE STOCKPILED IN SPACE FOR TENANT'S INSTALLATION. 4. TOILET ROOMS A) TO" X TO" PREHUNG HOLLOW CORE WOOD DOOR AND FRAME UNIT WITH LEVER HANDLE HARDWARE (PRIMER PAINT). B) UNSEALED EXPOSED CONCRETE FLOOR, BROOM CLEANED. C) WALL HUNG 18"X36" MIRRORS, WALL MOUNTED (HEIGHT PER CODE), ABOVE LAVATORY. D) ONE TOILET PAPER HOLDER MOUNTED 1'5" TO 17" AFF PER TOILET. E) GRAB BARS PER CODE. F) FLOOR MOUNTED, OVERHEAD BRACED, BAKED ENAMEL PARTITIONS, IF REQUIRED PER CODE. G) QUANTITY OF RESTROOMS/FIXTURES AS INDICATED ON LANDLORD'S DRAWINGS, H) TANK -TYPE HANDICAP ACCESSIBLE WATER CLOSETS. 1) WALL HUNG LAVATORIES WITH HANDICAP ACCESSIBLE FAUCET. PROVIDE STRAINER AND INSULATED PIPE GUARDS. J) ONE EXHAUST FAN, PER RESTROOM. K) ONE LIGHT SWITCH PER RESTROOM. L) ONE WALL MOUNTED FLUORESCENT FIXTURE. NOTE. ENLARGED RESTROOM DETAILS AND DRAWINGS ARE PROVIDED FOR GENERAL INFORMATION ONLY, ACTUAL RESTROOM CONFIGURATIONS AREAS SHOWN ON THE FLOOR PLANS FOR YOUR SPACE, PLUMBING/FIRE PROTECTION 1. WALL HUNG ELECTRIC WATER FOUNTAINS (AS INDICATED IN LANDLORD'S DRAWINGS AND/OR REQUIRED BY CODE FOR STANDARD RETAIL USE.) 2. MOP SINK PROVIDED, WHERE REQUIRED BY CODE. 3. 10 GAL. ELECTRIC WATER HEATER. HVAC 1. PROVIDE DISTRIBUTION FROM ROOF -TOP UNIT(S). A) NON -DIRECTIONAL DIFFUSERS B) ONE RETURN AIR GRILL, PER RTU C) REFER TO LANDLORD'S DRWINGS FOR STANDARD DUCTWORK DISTRIBUTION. 2. PROVIDE A STANDARD HEAT/COOL THERMOSTAT MOUNTED 5'0" AFF IN RETAIL SPACE. ELECTRICAL 1. PANEL AND SERVICE TO BE 120/208 VOLT, THREE (3) PHASE. K) 0- 999 SF 100 AMP PANEL, WITH CONDUIT FOR 200 AMP SERVICE L) 1,000 - 3,999 SF 200 AMP PANEL, WITH CONDUIT FOR 200 AMP SERVICE M) 4,000 - 5,999 SF 300 AMP PANEL, WITH CONDUIT FOR 400 AMP SERVICE N) 6,000 - 7,999 SF 400 AMP PANEL, WITH CONDUIT FOR 400 AMP SERVICE NOTE. WIRE MAYBE COPPER OR ALUMINUM 2. OUTLETS WALL MOUNTED DUPLEX OUTLETS AT 20'0" O.C. ALONG SIDE WALLS, 15.1'3' AFF ONE (1) DUPLEX OUTLET MOUNTED 4'6" AFF AT TELEPHONE: BOARD. ONE (1) GFI OUTLET IN EACH RESTROOM. 3. LIGHTING A) ONE (1) 2'0"X4'0" FOUR -TUBE LAY -IN FLUORESCENT FIXTURE - ONE (1) FIXTURE, PER 96 SF FOR 80% FOR THE SPACE AND ONE (1) FIXTURE PER 200 SF FOR THE REMAINING 20% OF THE SPACE. B) ONE (1) 24" FLUORESCENT TWO -LAMP LIGHT FIXTURE, WALL MOUNTED AT 6 - ABOVE ABOVE THE VANITY MIRROR IN EACH RESTROOM. C) EXIT LIGHT AT FRONT AND REAR DOORS AND WALL MOUNTED EMERGENCY LIGHTS, AS REQUIRED BY CODE (FOR THE STANDARD WHITE BOX FINISH). D) ONE (1) LIGHT SWITCH FOR EACH RESTROOM. 3. TELEPHONE PROVIDE'/" X 2'0" X 2'0" F.R.T. PLYWOOD BACKBOARD ON REAR WALL, AT TELEPHONE CONDUIT LOCATION. REVISION # 38 SUMMARY A. SHEET ADDED Architecture • Interior Design . Planning '`' 770.394.1616 1- 770.394.1314 r -T RE K J I I a E F C H C RD A 3 C D CONSULTANT SEAL REVISIONS 4 DATE DESCRIPTION A 10/18/04 SHOPS WHITE BOX Rus dccument Is Q Philrips Partnership. PC and is com;darcd on Instrument of Service and is soWy for use with rc. -&a to the project as indicated below. All rights reserved lz4 6vc=ent may not be reproduced without the pror .rrtten consent of Phillips Purtnership, PC. TEXANT t�* 2111 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER CLIENT NORTH AMERICAN PROPEM S NORTH AMERICAN PROPERTIES - ATLANTA 1430 HOLCO'dB BRIDGE ROAD BUILEECANG 2000, SUITE 150 ROS'PfELL, GA 30075 TEL (770);.45-8566 FAX (770) 643-9540 PHILLIPS JOB NUMBER -- 0208616 ISSUE DATE 05/14/04 DRAYIN a(/CHECKED BY ALE/DEB DRAWING TIP. -E FLOOR PI AN) DETAILS, ." & SPECS SHEET NUMBER 33 A Aml •_, .C. GENERAL NOTES 1. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE REQUIREMENTS OF THE 2000 FLORIDA BUILDING CODE (MECHANICAL), THE 2001 FLORIDA BUILDING CODE, THE 2000 FLORIDA ENERGY CODE, THE 2000 EDITIONS OF NFPA 90A & 101, UNDERWRITERS LABORATORIES (OR ETL) AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 2. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. 3. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE: ALL EQUIPMENT SCHEDULED OR SPECIFIED ON THE DRAWINGS; DUCTWORK DRAWN TO 1/4" SCALE OR -THE SCALE SHOWN ON THE DRAWINGS. 4. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. 5. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON-FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND ELECTRICAL DRAWINGS. 6. ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, DEVICES, ETC.) NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED ACCORDING TO CODE REQUIREMENTS. 7. UNLESS NOTED OTHERWISE, STARTERS, -TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 8. ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE AND ALL RECIRCULATING FAN SYSTEMS SERVING AREAS OF EGRESS SHALL BE INSTALLED WITH A SMOKE DETECTOR IN THE SUPPLY DUCTWORK. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN AIR PATH OF AIR DISTRIBUTION SYSTEMS UTILIZING A COMMON SUPPLY AND/OR RETURN AIR PLENUM WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM. THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, MOUNTED IN -THE DUCT BY THE MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. 9. INSTALL FIRE DAMPERS IN ALL RATED THROUGH WALLS, FLOOR AND CEILING PENETRATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OR RATED AREAS. PROVIDE ACCESS DOORS IN DUCTWORK AT EACH FIRE DAMPER LOCATION. INSTALL SMOKE DAMPERS IN ALL DUCT PENETRATIONS THROUGH SMOKE RATED WALLS. WHERE DUCTS PENETRATE WALLS THAT CARRY BOTH FIRE AND SMOKE RATINGS, THE DAMPERS INSTALLED SHALL BE COMBINATION FIRE AND SMOKE DAMPERS. ALL DAMPERS SHALL BE U.L. 555 LABELED. 10, ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 11, ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 12, ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 10 YEAR MANUFACTURER'S WARRANTY. 13. COORDINATE EXACT LOCATION OF ROOFTOP AIR CONDITIONING UNITS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 14. SUPPLY, RETURN AND O.A. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL AS RECOMMENDED IN SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS, LATEST EDITION. ALL JOINTS AND SEAMS IN ALL SHEEETMETAL DUCTWORK SHALL BE SEALED WITH DUCT SEALER. 15. SHEET METAL SUPPLY, RETURN, & O.A. DUCTWORK SHALL BE INSULATED WITH 2" THICK FIBERGLASS, 3/4 LB/FT3 DENSITY, DUCT INSULATION WITH FOIL VAPOR BARRIER, U.L. LISTED, R-6 MINIMUM. 16. EXHAUST DUCTWORK SHALL BE SHEET METAL AND SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. 17. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL BE AS PER SMACNA STANDARDS. 18. EXPOSED ROUND DUCTWORK SHALL BE MEDIUM PRESSURE SPIRAL TYPE, UNITED MCGILL OR EQUAL. 19. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M -KE (U.L. 181 LISTED, CLASS 1 FLEXIBLE AIR DUCT), R VALUE = 6.0 MINIMUM OR AS REQUIRED BY LOCAL ENERGY CODE. AIR CONNECTORS ARE NOT ACCEPTABLE. SIZE TO MATCH DEVICE NECK, PROVIDE ROUND GALVANIZED STEEL DUCT RUNOUTS TO MAINTAIN A MAXIMUM FLEXIBLE DUCT LENGTH OF 4'0". FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. 20. ROUND AND FLEXIBLE DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH SPIN?IN FITTINGS WITH SCOOP AND BALANCING DAMPER. 21. SHEET METAL DUCTWORK SHOWN AS BEING INTERNALLY LINED SHALL BE LINED WITH 1" THICK 3 LB./CU. FT. DENSITY DUCTLINER (MINIMUM R VALUE = 4.0 OR AS REQUIRED BY APPLICABLE ENERGY CODE C RTAINTEED fi0UGHGARD OR EQUAL BY KNAUF OR JOHNS -MANVILLE, PRODUCTS S BY OWENS-CORNING ARE NOT ACCEPTABLE. LINE ALL DUCTWORK A MINIMUM OF 10'0" DOWNSTREAM OF ALL AIR HANDLING UNITS, FAN COIL UNITS AND TERMINAL UNITS. THE LEADING EDGE OF THE DUCT LINER SHALL HAVE SHEETMETAL NOSING. 22. PORTIONS OF DUCTWORK VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 23. DIMENSIONS DUCTWORK S SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. T N I DCONDENSATE PIPING SHALL U TO THE NEAREST ROOF RAIN GUTTER. 24. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED DRAIN/ GUTTER, SCHEDULE 40 PVC. CONDENSATE SHALL BE PUMPED AS REQUIRED. 25. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. TEST AND BALANCE REPORT SHALL BE PREPARED BY AN INDEPENDENT TESTING AND BALANCING CONTRACTOR WHO IS A MEMBER OF THE AABC OR NEBB. REPORT SHALL INCLUDE THE FOLLOWING TEMPERATURE READINGS, IN ADDITION TO AIR FLOWS: AIR LEAVING DIFFUSERS, AIR LEAVING HVAC UNIT, OUTSIDE AMBIENT AT TIME OF TEST. SUBMIT CERTIFIED TEST AND BALANCE REPORT TO OWNER/ARCHITECT FOR APPROVAL. 26. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS. 27, CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. 28. PROVIDE ACCESS PANELS IN NON -ACCESSIBLE CEILINGS AND IN WALL STRUCTURE TO ALLOW ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEM. ACCESS PANELS IN CEILING AND WALLS SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS OR NECESSARY TO ACCESS DAMPERS, VALVES, ETC. COORDINATE EXACT LOCATION OR ALL ACCESS PANELS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS. 29. MOUNT THERMOSTATS AND/OR SENSORS 4'0" AFF UNLESS NOTED OTHERWISE. 30. ALL ROOFTOP MOUNTED EQUIPMENT SHALL BE INSTALLED LEVEL ON AND ANCHORED TO MINIMUM 12" HIGH INSULATED ROOF CURBS. CONTRACTOR SHALL COORDINATE ROOF SLOPE AND ACTUAL CURB HEIGHTS WITH ARCHITECTURAL DRAWINGS. ALL REFERENCES TO ROOF HEIGHTS REFER TO HEIGHTS ABOVE FINISHED ROOF SURFACE. 31. LOCATIONS OF GRILLES, REGISTERS, & DIFFUSERS SHOWN ON THE DRAWINGS ARE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, ETC. AND ARCHITECTURAL REFLECTED CEILING PLAN. 32. ROOFTOP HVAC UNITS SHALL BE INSTALLED SUCH THAT ROOF DECK IS COMPLETE AND CONTINUOUS UNDER BOTTOMS OF HVAC UNITS, AND SHALL BE CUT ONLY FOR UNIT SUPPLY AND RETURN OPENINGc. PACE BETWEEN ROOF DECK AND BOTTOM OF ROOFTOP FIVA, UNIFY IN -SIDE OF ROOF CURBS SHALL BE FILLED WITH HIGH DENSITY ACOUSTICAL INSULATION. 33. ALL MECHANICAL EQUIPMENT SHALL BE LABELED WITH BAKELITE NAMEPLATE WITH 2" HIGH WHITE LETTERS ON A BLACK BACKGROUND, NAMEPLATE SHALL SHOW TENANT AND/OR SUITE SERVED. TOTAL TRAP HEIGHT = X + H + 1.5 D WHERE: H = AT LEAST i" PLUS CASING SP D = PIPE DIAMETER PIPE TO NEAREST ROOF GUTTER TOTAL TRAP HEIGHT CONDENSATE FROM ROOFTOP AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO DISCHARGE INTO THE NEAREST GUTTER/DOWNSPOUT - COORDINATE GUTTER LOCATIONS WITH ARCHITECTURAL ROOF PLAN. CONDENSATE DRAIN PIPING TO BE ROUTED ON ROOF, SUPPORTED ON BLOCKING AT MAXIMUM 8 FOOT CENTERS, AND SLOPED AT 1/8" PER FOOT MINIMUM. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC. MULTIPLE UNITS MAY HAVE CONDENSATE PIPING MANIFOLDED INTO A COMMON PIPE TO DRAIN. UNLESS INDICATED OTHERWISE ON DRAWINGS, CONDENSATE DRAIN PIPING SHALL BE SIZED PER THE FOLLOWING CRITERIA: 3/4" FOR UP TO 2 TON CONNECTED COOLING LOAD; 1" FOR 2 THRU 5 TONS; 1-1/4" FOR 5 THRU 30 TONS; 1-1/2" FOR 30 THRU 50 TONS; 2" FOR 50 TO 170 TONS; 3" FOR 170 TO 300 TONS; 4" FOR 300 THRU 430 TONS. C, ONDENSATE DRAIN TRAP DETAIL I NOT TO SCALE VV - _._-_.. v F......................................... ..............I:: I, Y--- ------------------------------- ______ <. WHITE BOX FLOOR PLAN - H.V.A.C. SCALE: 1/8" = V-0" FAN AND VENTILATOR SCHEDULE PACKAGED ROOFTOP H.V.A.C. TAG TYPE CFM ACCESSORIES: S.P. DRIVE MOTOR WATTS MAX. DUTY RPM MODEL REMARKS 25% TAG NOMINAL MODEL NO. TONNAGE AIRFLOW (CFM) E.S.P. (IN. W. C.) MAXIMUM O.A. CAPABILITY MAXIMUM FAN H. '. TOTAL COOLING (MBH) SENSIBLE COOLING (MBH) EF -1 CABINET CENTRIFUGAL 85 - 0 DIRECT . 25" ----------- 50 1200 EXHAUST PENN ZEPHYRETTE ZT 1,2,3,4,5 SUPPLY STEEL . B ........................... .. . .. ........................................................................... ( TITUS PAS ................._ 24X24 i 8"� .......... ..................................................................................................................................................................................................... YES ] 1 REMARKS /ACCESSORIES: 1. CABINET CENTRIFUGAL EXHAUST FAN WITH INTEGRAL TRHERMAL OVERLOAD PROTECTION 2. DISCONNECT SWITCH/PLUGS 3. INTEGRAL_ GRAVITY BACKDRAFT DAMPER 4. CONTROLLED VIA WALL SWITCH 5. DISCHARGE TO WALL OR ROOF CAP W/SCREEN & FLASHING (SEE PLANS) SELECTIONS BASED ON EQUIPMENT MANUFACTURED BY PENN VENTILATOR. EQUALS BY COOK, GREENHECK. AIR DISTRIBUTION SCHEDULE TAG MODEL SIZE NECK DAMPER 25% FINISH 36.6 DUTY -7MATERIAL RTU A TITUS PAS 24X24 6"0 YES I...................... 1-1/2 MANUF. STD WHITE SUPPLY STEEL . B ........................... .. . .. ........................................................................... ( TITUS PAS ................._ 24X24 i 8"� .......... ..................................................................................................................................................................................................... YES ] 1 MANUF. STD WHITE SUPPLY ................................................................................ STEEL C TITUS PAS 24X24 ..........................................._.....-........................................„._......................................................._-- 10"o YES TENANT MANUF. STD WHITE -. ............................................................................................................................................................................... SUPPLY STEEL ............................................................................................................................................................................................ D TITUS PAS ..................... 24X24 11 .. . 12"0 YES I MANUF. STD WHITE SUPPLY STEEL E TITUS PAS 24X24 14"0 YES 7. MANUF. STD WHITE SUPPLY STEEL ............ ......................... .................................... F .............. ....... TITUS 5OF ............:............... .................................................................................. 24X24 ............................. --- ........................ ................. ......... NO ............... ....... ................................................................ MANUF. STD WHITE ............................................................... ; .... RETURN ALUMINUM COORDINATE MOUNTING FRAME REQUIREMENTS WITH ARCHITECTURAL REFLECTED CEILING PLANS. SELECTIONS BASED ON EQUIPMENT MANUFACTURED BY TITUS. EQUAL PRODUCTS BY KRUEGER, METAL-AIRE. CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON TIES. INTERIOR LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. INSTALL USING TENSIONING TOOL AS PERS MANUFACTURER'S RECOMMENDATIONS. ROUND SHEET METAL DUCT. DIAMETER AS INDICATED ON PLANS TRUNK DUCT/ NYLON TIES INTERIOR LINER PRE -INSULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. LENGTH NOT TO EXCEED 4'-0". PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL FREE OF KINKS &. SAGS. SPIN -IN FITTING - WITH DAMPER & SCOOP FOR SUSPENDED CEILING. SUPPLY DIFFUSER OR SUPPLY AIR APPLICATIONS, SEE ARCH. PLANS RETURN AIR GRILLE PLAIN SPIN -COLLAR FOR FOR TYPE. RETURN APPLICATIONS e was] ►► �► I7_arad, II NOT TO SCALE RTU -3 3 CARRIER 50TME004 1200 1.0' 25% 1 36.6 26.0 RTU -4 ; 4 s CARRIER 5OTME005 1600 1.0" 25% 1-1/2 50.5 35.6 RTU -5 i................................................................................................................................................................................................................................................................................................................................................ ......................................................................................................................................................................... I 5 CARRIER 50TME006 2000 1.0 ............ 25% ..... ? 60.9 45.3 ................................... RTU .................................... -6 6-1/2 j CARRIER 50TME007 . ............................................... ........................ .........................................................................................(...... 2400 10" l . .............................. 25% ........ ................. ' . 76.z............�....... ........................56.8 NOTE: TENANT COOLING CAPACITIES ARE BASED ON 95*17 DB AMBIENT, 80'F DB/'&'F WB EAT. BOX SHOP ACCESSORIES: PROJECT 1. PREFABRICATED FULL- PERIMETER ROOF CURB, 14 INCH HIGH (COORDINATE SLOPE WITH ARCHITECTURAL) 2. FACTORY -INSTALLED ELECTRIC HEATERS & CONTROLS CLIENT - 3. SINGLE -POINT POWER CONNECTION W/NON-FUSED DISCONNECT 4. GFCI CONVENIENCE OUTLET (120 VOLT) PHILLIPS JOB NUMBER 5. HIGH EFFICIENCY BLOWER MOTOR 10/18/04 6. LOW AMBIENT COOLING TO 457. DRAWING TITLE 7. 0-25% OUTSIDE AIR HOOD WITH TWO -POSITION DAMPER H.V.A.C. 8. ELECTRONIC DIGITAL THERMOSTAT, AUTOMATIC -CHANGEOVER, PROGRAMMABLE 900D CENTRAL PA Wf� 9. SMOKE DETECTOR (SEE GENRAL NOFES) SELECTIONS BASED ON EQUIPMENT MANUFACTURED BY CARRIER. APPROVED EQUALS BY TRANE, YORK. CONDENSER FAN DISCHARGE OUTDOOR AIR INTAKE/ECONOMIZER DISCONNECT (SEE HOOD (WHERE APPLICABLE) - � ELECTRICAL DWGS.) BAROMETRIC HOOD 7 (WHERE APPLICABLE) II' CONDENSATE DRAIN TO BE ROUTED ON ROOF TO NEAREST ROOF DRAIN PREFABRICATED UNLESS NOTED OTHERWISE ROOF CURB K , - ROOF DECK POWER WIRING s (SEE ELECTRICAL) THERMOSTAT WIRING SUPPLY AIR DUCT TRAP RETURN AIR DUCT NOTE: ALL CONNECTIONS AND SERVICES MUST BE INSIDE THE PERIMETER CURB. DISCONNECT SWITCHES, BRACKETS, AND CONDUIT MUST BE CLEAR OF ALL UNIT PANELS AND AIR FLOW. BRACKETS MUST BE TO STRUCTURAL MEMBERS OF UNIT. ROOFTOP AIR CONDITIONER DETAIL NOT TO SCALE OPERATING COOLING KW EFFICIENCY ELECTRIC CONSULTANT HEATER 10.0 SEER 12.3 .................................................................. 10.0 SEER 15.8 10.0 SEER ...............::15.8....... ... ....... 635 LBS, ....................................................... 10.3EER 15.8 II' CONDENSATE DRAIN TO BE ROUTED ON ROOF TO NEAREST ROOF DRAIN PREFABRICATED UNLESS NOTED OTHERWISE ROOF CURB K , - ROOF DECK POWER WIRING s (SEE ELECTRICAL) THERMOSTAT WIRING SUPPLY AIR DUCT TRAP RETURN AIR DUCT NOTE: ALL CONNECTIONS AND SERVICES MUST BE INSIDE THE PERIMETER CURB. DISCONNECT SWITCHES, BRACKETS, AND CONDUIT MUST BE CLEAR OF ALL UNIT PANELS AND AIR FLOW. BRACKETS MUST BE TO STRUCTURAL MEMBERS OF UNIT. ROOFTOP AIR CONDITIONER DETAIL NOT TO SCALE REVISION # 38 SUMMARY A. ADDED SHEET 111111111111110 VVW PHILLIPS OPERATING ACC%S50?1 S WEIGHT K J (LBS.) CONSULTANT 485 LBS. 1-3 495 LBS. 1-3 515 L. 1-3 ... ....... 635 LBS, 1-8 REVISION # 38 SUMMARY A. ADDED SHEET 111111111111110 VVW PHILLIPS P A R T N E R S H I P Ard itec xe - Interior Design ■ Planning 770.394.1616 770.3941314 K J t L E F O H C A Agit r! a4 3 C D '1 CONSULTANT TjJordan Skala Engineers, Inc. 73Project Nunber • 0410070 5365 GV -W- X PJ.?r", ICRCROSS, G4 30093 PME (T79j4ijscO7-SF,47 FAX (770),48-0262 �: prSor�-com COPr&Gff 6 Z04 XR`AN # VqA DC4EEERS INC. SEAL 1 IQ� REVISIONS rr DATE DESCRIPTION 10/18/04 SHOPS WHITE BOX Iris .Zf w.=,WA IS i3 PnilEps Partnership, PC and is GfYSitrb7 t r2str.9rtAt :: S4rf.!e arkl is Solely for use With w. Alrig hts reserved. res;r_t :'>' ---.eprya:l =lF..r_ated :?/o� Tris *.r.:,mAz4 srr_7 m4 :.n repfc6 ced without the prior ..rtto of Pru;s Partnership, PC. TENANT STANDARD WHITE BOX SHOP 2111 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOL.E TOWNE CENTER 0 SANFORD, FLORIDA CLIENT - �k NORTH AMERICAN PROPERTIES NORTri AMERICAN PROPERTIES - ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROSWEL! , GA 30075 TEL (770) 645.6566 FAX (770) 643-9540 PHILLIPS JOB NUMBER 0208616 ISSUE DATE 10/18/04 DRAWN BY/CHECKED BY MLW/GMS DRAWING TITLE WHITE BOX FLOOR PLAN H.V.A.C. SHEET NUMBER m 1 ■ 900D CENTRAL PA Wf� 400 mi •R 1 1/'2" DOMESTIC SERVICE B/F & UP ' 4"F TO FDC i f ` � •• r 6"F B/F & UP W/ BACKFLOW PREVENTOR I INSTALLED IN VERTICAL i I I `'• i I I L. _......,, - P8B: 2"W 2"V 1/2"CW ......... ... ; ...... 4"S B/G 0 '1 %, I.E. 50.67' I ' 111: 4"1, 4"V, 1 /2"CW P1H I. ••I.f/ � i H , 2 r --------- TERMINATE 1/2 T&P DISCHARGE 6" MIN. AFG :11. : .y...: ........�.,........ .... .......... P2WH: 2"W 2"V 1 /2"HW/CW 4"V UP&VTR EWH-1: MOUNTED A�C, A/0. SMITH MODEL ELC-2, 1/2' INLET/OUTLET, RUN T&P DISCHARGE A/C & DN, TERMINATE 6" AFO. r. 11-1 4" VTR WATER I v2 11 COOLER 1 `I 2,r �> 2"• 1 � I � 14x, 2» i / I 1 WC 1 2' LAV ( 4" 4 DIELECTRIC UNION (TYI ASME T&P RELIEF VAL DISCHARGE FULL SIZE & TERMINATE 6" MIN. 1 1/2" HIGH SAFETY 1 " DRAIN ROUTE A/C TERMINATE 6" MIN. AR 1 1/2" X3/4" WATER COOLER \ 1 `. �\ I `3/4" 13/4" WH 1 I I WC , .1 /2» I I I 2° LAV Fes/ 1/2" 1/2" SANITARY AND DOMESTIC WATER IS-OMETRICS) SCALE: N.T.S CEILING SUSPENDED EWH SCALE: N.T.S. __ GALLON EXPANSION TANK VACUUM RELIEF GATE VALVE (TYP.2) 1/2" CW SUPPLY 1/2" HW OUTLET 3/4" CADMIUM PLATED ALL THREAD ROD WITH LOCK WASHERS AND DOUBLE NUTS (TYPA) SOLDER SEAMS WATER TIGHT CROSS BREAK BOTTOM OF PAN TO DRAIN POINT 2" X 2" X 1/4" GALVANIZED ANGLE IRON FRAME DRAIN VALVE x f r)e 's, HS{ xxxxx:: r„i ff WHITE BOX FLOOR PLAN SCALE: 1/4" = V-0" S S .. t 2142 x >..........:::tom ...............:::::::::::: D.B" w 1 i 2"CW TO SYSTEM (SEE DRAWINGS FOR EXACT SIZES) PRV-2 SEE SCHEDULE PRESSURE GAUGE (TYP.) UNION (TYP.) PRV-1 SEE SCHEDULE STRAINER (TYP.) ituw.i uwvn IVVIC. THIS DETAIL APPLIES ONLY IF THE WATER PRESSURE AT THE SERVICE ENTRANCE EXCEEDS 80 PSI. DOMESTIC WATER SERVICE ENTRY DETAIL MOTOR GONG "'""" ON OUTSIDE W 4" TO FIRE DE CONNECTION 2" ANGLE CHE 2" SIGHT GLAS 1 1/4" DRAIN 1 1/4" CHEC14 3" DRAIN EXTE THRU WALL SCALE: N.T.S 6" FIRE SERVICE WITH ROD AND CLAMPS TO SPRINKLERS ALARM VALVE PRESSURE GAUGE (TYP.) PRESSURE SNITCH RETARD CHAMBER 1 1/2" DRAIN FINISHED FLOOR - .._......_....,..__..._. . ...... -- .......... I ........................ - THRUST BLOCK ERE SERVICE ENTRANCE DETAIL SCALE: N.T.S. DRAINAGE PRODUCTS/SPECIALTIES UNLESS OTHERWISE INDICATED NUMBERS ARE JAY R. SMITH, EQUAL PRODUCTS: ZURN, JOSAM, WADE AND WATTS. CO -EXPOSED CLFANOUT - UNFINISHED AREAS JAY R. SMITH FIG, 4420 CAST BRONZE COUNTERSUNK PLUG WITH SLOT TO RECEIVE 1/2" THICK STEEL BAR STOCK. WCO-WALL CLEANOUT - FINISHED AREAS JAY R. SMITH FIG. 4436 C.I. FERRULE FOR NO HUB OR SERVICE WEIGHT PIPE, NICKEL BRONZE ROUND FRAME AND COVER WITH SECURING SCREWS. FCO -CONCRETE FLOORS JAY R. SMITH FIG. 4220 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASY REMOVAL, ADJUSTABLE ROUND CAST IRON TOP WITH SECURING SCREW, SPEEDI-SET OUTLET CONNECTION. FCO -TILE FLOORS JAY R. SMITH FIG. 4151 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASY REMOVAL, ADJUSTABLE ROUND NICKEL BRONZE TOP RECESSED FOR TILE WITH SECURING SCREW, SPEEDI-SET OUTLET CONNECTION. FCO -CARPETED FLOORS JAY R. SMITH FIG. 4020-Y C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG, ADJUSTABLE ROUND NICKEL BRONZE TOP COMPLETE WITH STAINLESS STEEL CARPET MARKER WITH SECURING SCREW, SPEEDI-SET OUTLET CONNECTION. LAVATORY -WALL HUNG SUPPORT JAY R. SMITH #700 FOR MASONRY WALLS AND #/00-M31 FOR METAL STUD WALLS. ELECTRIC WATER COOLER CARRIER -WALL HUNG JAY R. SMITH FIG. 830 SUPPORT WITH UPRIGHTS OF HIGH STRENGTH STEEL WITH WELDED BASES BOLTED TO FLOOR. FOR STEEL STUD WALLS, USE M31 RECTANGULAR UPRIGHTS, PLUMBING NOTES 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ALL PLUMBING FIXTURES, 2. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 2001 FLORIDA PLUMBING CODE WITH ALL APPLICABLE LOCAL CODE AND ORDINANCES. 3. ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED FROM THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR BE SUPPORTED FROM CEILING TILES. 4. WATER PIPING ROUTED ABOVE CEILING AND IN EXTERIOR WALLS SHALL BE ROUTED ON HEATED SIDE (UNDERSIDE) OF CEILING INSULATION AND HEATED SIDE (INSIDE) OF WALL INSULATION, 5. SANITARY AND DRAINAGE PIPING 2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM, PIPING 3" AND LARGER SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM. » 6. LOCATE ALL SECTIONAL 0 - R MAIN CONTROL VALVES WITHIN 1 0 FROM ACCESS PANELS, CEILING TILES, OR OTHER POINT OF ACCESS. 7. ALL COLD WATER, AND DRAIN PIPING AT HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI-LAV GUARD MODELS 102 AND 105 INSULATION KITS. 8. PROVIDE SHOCK ABSORBERS SIZED PER PDI SPECIFICATIONS ON ALL DOMESTIC WATER LINES SERVING PRV STATIONS AND OTHER INSTALLATIONS WITH QUICK CLOSING VALVES. 9. PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL PIPING SYSTEMS CROSSING BUILDING EXPANSION JOINTS. 10. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC. INSTALLED IN HVAC PLENUM SPACES SHALL. MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 11. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. 12. ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE RATED ASSEMBLIES SHALL BE FIRE STOPPED AS REQUIRED TO RESTORE ASSEMBLY TO ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY 3M COMPANY, CP25 CAULK, CS195 COMPOSITE PANEL, FS195 WRAP/SKINK, OR PSS 7900 SERIES SYSTEMS AS RECOMMENDED BY MANUFACTURER FOR PARTICULAR APPLICATIONS, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS, 13. ALL VENT THRU ROOF PENETRATIONS SHALL BE ROUTED TO TERMINATE AT THE LEAST VISIBLE LOCATION FROM THE ENTRY VIEW. PLUMBING MATERIALS 1. COLD AND HOT WATER PIPING ABOVE GRADE SHALL BE TYPE L HARD DRAWN COPPER TUBING CONFORMING TO ASTM B-88 WITH SWEAT JOINTS AND CAST OR WROUGHT FITTINGS. ALL JOINTS SHALL BE MADE WITH LEAD FREE SOLDER, DOMESTIC COLD WATER SERVICE PIPING BELOW GRADE SHALL BE CEMENT LINED DUCTILE IRON PIPE WITH PUSH -ON JOINTS. DOMESTIC WATER BRANCH PIPING BELOW GRADE SHALL BE PROTECTED WITH SLEEVES AT ALL PENETRATIONS THROUGH CONCRETE. 2. SANITARY WASTE & VENT PIPING ABOVE GROUND SHALL BE NO -HUB CAST-IRON WITH STAINLESS STEEL COUPLINGS, OR SCHEDULE 40 DWV PVC WITH SOLVENT JOINTS IF APPROVED BY LOCAL CODE OFFICIAL. PVC PIPING SHALL NOT BE LOCATED IN RETURN AIR PLENUM SPACES. 3. SANITARY WASTE PIPING BELOW GROUND SHALL BE CAST-IRON WITH PUSH -ON JOINTS, OR SCHEDULE 40 DWV PVC WITH SOLVENT JOINTS. 4. ALL ABOVE GRADE HOT AND COLD DOMESTIC WATER PIPING SHALL BE INSULATED EXCEPT AT HORIZONTAL CHASE BRANCH PIPING TO INDIVIDUAL PLUMBING FIXTURES AND ON VERTICAL RISERS WITHIN SEALED CHASES. ALL HOT WATER PIPING ABOVE GRADE SHALL BE INSULATED WITH 1 INCH NOMINAL THICKNESS PIPE INSULATION WITH VAPOR BARRIER JACKET, ALL COLD WATER PIPING ABOVE GRADE SHALL BE INSULATED WITH 1/2 INCH THICKNESS INSULATION ON PIPING 2" AND SMALLER, 1" THICK INSULATION ON PIPING 2 1/2" AND LARGER. OWENS-CORNING ASJ/SSLII OR EQUAL. PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION F A/C ABOVE CEILING ELECTRICAL CRITERIA-- A/F ABOVE FLOOR 4" AFF ABOVE FINISHED FLOOR CAPACITY AFG ABOVE FINISHED GRADE KW B/F BELOW FLOOR ELECTRIC WATER COOLER B/G BELOW GRADE - - - CW COLD WATER PIPING c DN PIPING TURNING DOWN fX]- CV GATE/BALL VALVE 1-3 H.C. HANDICAPPED - -- --- HW HOT WATER PIPING oc --- P -TRAP -- S Sy SOIL, WASTE PIPING (ABOVE GROUND) -- _S__ Sy SOIL, WASTE PIPING (BELOW GROUND) ----11; --- UNION �- UP PIPING TURNING UP - V VENT PIPING VTR VENT THRU ROOF Imo- W WALL CLEANOUT FIRE PROTECTION SYSTEM MATERIALS 1. ALL MATERIALS, PIPE, VALVES AND EQUIPMENT FURNISHED UNDER THIS SECrm SHALL BE NEW AND APPROVED BY NFPA, UNDERWRITER'S LABORATORIES, 11►C. (U.L.), FACTORY MUTUAL (F/M) AND AMERICAN WATER WORKS ASSOCIATI" (A1 AA) WHERE APPLICABLE. 2. SCHEDULE_ 40 WELDED OR SEAMLESS STEEL PIPE, ASTM A53, AND A135. A. CLASS 125, AND 250 CAST IRON THREADED FITTINGS, ANSI B16.4. B. CLASS 150, AND 300 MALLEABLE IRON THREADED FITTINGS, ANSI B16.3. C. GROOVED MECHANICAL COUPLINGS AND FITTINGS WITH EPDM CASKET, MALLEABLE IRON OR DUCTILE IRON, 800 PSI MINIMUM RATING ASTM A47 AND A536, U.L. LISTED, F.M. APPROVED. 3. LIGHTWALL WELDED OR SEAMLESS STEEL PIPE, ASTM A53, AND A135. A. GROOVED MECHANICAL COUPLINGS AND FITTINGS WITH EPDM GASKET, MALLEABLE IRON OR DUCTILE IRON, 800 PSI MINIMUM RATING ASTM A47, AND A536, U.L. LISTED, F.M. APPROVED. B. LIGHTWALL, 150 PSI, BUTTWELD FITTINGS, ANSI 816.9, 4. AUTOMATIC SPRINKLERS SHALL BE PROVIDED AS FOLLOWS: A. SMALL FRAME GLASS ELEMENT, SEMI -RECESSED, FAST RESPONSE PENDENT SPRINKLERS SHALL BE PROVIDED IN ALL AREAS WITH LAY -IN CEILINGS UNLESS OTHERWISE NOTED. TEMPERATURE RATING OF SPRINKLERS SHALL BE 155' - 165'. SPRINKLERS TO BE VIKING MICROFAST MODEL M SERIES WITH MODEL E-1 ESCUTCHEON, FINISH OF SPRINKLER AND ESCUTCHEON SHALL BE WHITE. B. FAST RESPONSE UPRIGHT PENDENT SPRINKLERS SHALL BE PROVIDED IN ALL AREAS WITH NO CEILING. TEMPERATURE RATING IS TO BE 165' UNLESS CONDITIONS REQUIRE HIGHER TEMPERATURE. FINISH OF SPRINKLER TO BE ROUGH BRASS. SPRINKLER TO BE VIKING MICROFAST MODEL M. C. ALTERNATE ACCEPTABLE MANUFACTURERS WITH EQUIVALENT SPRINKLERS ARE AUTOMATIC, CENTRAL, GRINNELL, GEM, AND RELIABLE. 5. ALL INTERIOR SPRINKLER PIPING SHALL MEET THE REQUIREMENTS OF APPLICABLE SECTIONS OF NFPA, AND THE OWNER'S UNDERWRITER. ALL PIPE, FITTINGS, VALVES, AND SPRINKLER SYSTEM COMPONENTS SHALL BE RATED FOR WORKING PRESSURES AS REQUIRED BY SYSTEM DESIGN. 6. ALL PIPE, SUPPORTS AND HANGER ASSEMBLIES SHALL BE IN ACCORDANCE WITH NFPA-13 AND SHALL BE U.L. LISTED OR F.M. APPROVED, T THE ADDITION TO THE EXISTING SPRINKLER SYSTEMS SHALL BE DESIGNED TO THE EXISTING AVAILABLE WATER SUPPLY PRESSURE. THE CONTRACTOR SHALL CONFIRM THE REVISED SPRINKLER PIPING ARRANGEMENT WITH HYDRAULIC CALCULATIONS. 8. THE TENANT BUILD -OUT AREA IS TO BE PROVIDED WITH AUTOMATIC SPRINKLERS BASED UPON LIGHT HAZARD DESIGN CLASSIFICATION WITH A DENSITY OF .10 GPM OVER 1500 SQ. FT. AND MAXIMUM OF 225 SQUARE FEET SPACING. 9. SPRINKLER HEADS INSTALLED IN LAY IN ACOUSTICAL TILE CEILINGS SHAH BE CENTERED IN THE CEILING TILES OR INSTALLED ON QUARTER POINTS OF THE FOUR FOOT DIMENSIONS OF 2' X 4' TILES. 10. ALL FIRE PROTECTION EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE, 11, ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM 'THE TOP CHORDS OF THE JOISTS. 12. ALL SPRINKLER PIPING SHALL BE ROUTED TO MAINTAIN DESIGNED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. 13. ALL FIRE PROTECTION DRAWINGS SUBMITTALS SHALL BE AT 1/8" SCALE AS A MINIMUM. ALL SUBMITTALS SHALL BE IN REPRODUCIBLE VELLUM OR MYLAR FORMAT ONLY SUBMITTALS OF MULTIPLE PRINTS WILL BE RETURNED WITHOUT REVIEW. 14. FIRE PROTECTION SHOP DRAWINGS SHALL INCLUDE ALL DATA REQUIRED BY N.F.P.A. SECTION 13. SHOP DRAWING PLANS SHALL INDICATE ALL LIGHTS, GRILLES, SOFFITS, ALARMS, SPEAKERS AND OTHER CEILING COMPONENTS, AS WELL AS HYDRAULIC NODE POINTS, TO INSURE COORDINATION. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO AND SECURE APPROVAL OF THE OWNER'S UNDERWRITER, LOCAL AUTHORITY AND/OR STATE AUTHORITIES PRIOR 'TO SUBMISSON TO THE ENGINEER, THE CONTRACTOR SHALL NOT COMMENCE WORK, PURCHASE, OR PROVIDE ANY MATERIALS TO THE JOB SITE WITHOUT OBTAINING SHOP DRAWING APPROVAL FROM THE ABOVE AND THE ENGINEER. SHOP DRAWINGS SHALL INCLUDE COPIES OF ALL HYDRAULIC CALCULATIONS PROVIDING DESIGN DENSITIES, WHERE APPLICABLE. 15. ALL DESIGN DRAWINGS AND CALCULATIONS PREPARED BY THE FIRE PROTECTION SUBCONTRACTOR SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL_ ENGINEER LICENSED IN THE STATE OF GEORGIA OR EQUIVALENT FIRE SPRINKLER CONTRACTOR'S CERTIFICATE SEAL. PLUMBING FIXTURE SCHEDULE FIXTURE SELECTION IS BASED ON KOHLER MODELS UNLESS OTHERWISE NOTED, APPROVED EQUAL MANUFACTURERS AS FOLLOWS: FIXTURES: ELDAY, JUST FAUCETS & TRIM: KOHLER, AMERICAN STANDARD, BRASSCRAFT, DELTA, MCGUIRE, SANITARY DASH, ZURN P1H WATER CLOSET - FLOOR MOUNTED - TANK - ELONGATED - SEAT W/COVER - PUBLIC: AMERICAN STANDARD 2216.143 - FLOOR MOUNT, TANK TYPE, COMBINATION FIXTURE, 1.5 GALLON FLUSH, VITREOUS CHINA, ELONGATED SIPHON JET, CHROME PLATED ACTUATOR, BOLT CAPS, WHITE. SEAT - BENEKE 520-FIPSS COMMERCIAL GRADE SOLID PLASTIC, ELONGATED. CLOSED FRONT SEAT WITH COVER, STAINLESS STEEL POSTS AND SELF-SUSTAINING HINGES, WHITE. SUPPLY - BRASSCRAFT OCR1912 - 1/2" O.D. X 3/8" O.D. ANGLE STOP, WHEEL_ HANDLE, WALL FLANGE, CHROME PLATED. P2WH LAVATORY - WALL HUNG - GRID DRAIN: KOHLER K-2005 21" X 18" WALL HUNG LAVATORY, 4" CENTERS, CONCEALED ARMS, FRONT OVERFLOW AND BACKSLASH, WHITE. FAUCET - KOHLER K-15199 SINGLE LEVER HANDLE, 4" CENTERS, FLOW RESTRICTOR, WITH GRID DRAIN REPLACEABLE CERAMIC DISC CARTRIDGE, AERATOR, 1 1/4" TAILPIECE, CHROME FINISH. SUPPLY - BRASSCRAFT SR1712A - 1/2" O.D. X 3/8" O.D. ANGLE SUPPLY, LOOSE KEY STOP, WALL FLANGE, CHROME PLATED. TRAP - MCGUIRE 8902 - 1 1/4" X 1 1/2", 17 GAUGE ADJUSTABLE TRAP WITH CLEANOUT AND WALL FLANGE, CHROME FINISH. DRAIN - MCCUIRE 155 -WC - 1 1/4", 17 GAUGE OFFSET DRAIN WITH OPEN GRID STRAINER, CHROME PLATED. LAVATORY WASTE TRAP PRIMER - JAY R. SMITH 2698 - 1 1/4", 17 GAUGE ADJUSTABLE WITH CLEANOUT AND WALL FLANGE, TRAP PRIMER TUBING WITH WALL FLANGE, CHROME PLATED. PROVIDE IN LIEU OF STANDARD TRAP AT LOCATIONS INDICATED ON DRAWINGS. INSULATION KIT - HANDI LAV -GUARD MODEL 102 AND 105 - SELF FASTENING, VINYL INSULATION COVERS FOR DRAIN, TRAPS, AND SUPPLY PIPING WITH ACCESSIBLE ANGLE VALVE INSULATION COVER, WHITE. CARRIER - SMITH 700 SERIES - ADJUSTABLE FLOOR SUPPORT WITH CONCEALED ARMS. P813 ELECTRIC WATER COOLER: OASIS P8ACSL WALL MOUNTED BARRIER FREE BI -LEVEL COOLERS, FRONT PUSHBUTTON OPERATION, HEAVY GAUGE STAINLESS STEEL, UNIT 'TO PROVIDE MINIMUM 8 GPH OF 50T WATER WITH 90'F AMBIENT AND 80'F SUPPLY WATER TEMPERATURE, VINYL FINISH. SUPPLY - MCGUIRE ST07 - 1/2" O.D. X 3/8" O.D., WHEEL HANDLE STOP. TRAP - MCGUIRE 8902 - 1-1/4" X 1-1/2", 17 GAUGE ADJUSTABLE TRAP WITH CLEANOUT, CHROME FINISH. FIRE PROTECTION LEGEND SYMBOL ABBREVIATION DESCRIPTION F F FIRE PROTECTION SUPPLY ELECTRICAL CRITERIA-- SFDC SIAMESE FIRE DEPARTMENT CONNECTION WATER HEATER SCHEDULE SYMBOL LOCATION/ STORAGE GPH HOT WATER SUPPLY ELECTRICAL CRITERIA-- NOTES WATER CLOSET- PUBLIC 4" --- MODEL NO. CAPACITY REC./TEMP. RISE OUTLET KW 1/2" P813 ELECTRIC WATER COOLER GALLONS RISE TEMPERATURE INPUT EWII-1 ABOVE CEILING/ 21/2 8.3/75T 120'F 1.5 1-3 ELC-2 NOTES: 1. PROVIDE T&P RELIEF VALVE AND VACUUM RELIEF VALVE 2. PROVIDE GATE/BALL VALVES WITH UNIONS AND DIELECTRIC FITTINGS ON WATER INLET AND OUTLET CONNECTIONS. 3. DESIGN BASIS: A.O. SMITH, POINT -OF -USE, SINGLE ELEMENT OPERATION. FIXTURE SCHEDULE s ------------------- MINIMUM SIZE UTILITY TO FIXTURE FIXTURE # FIXTURE TYPE WASTE CONNECTION HOT WATER SUPPLY COLD WATER SUPPLY P1H WATER CLOSET- PUBLIC 4" --- 1/2" P2WH LAVATORY - PUBLIC 1 1/4" 1/2" 1/2" P813 ELECTRIC WATER COOLER 1 1/4" --- 1/2" REVISION # 38 SUMMARY A. ADDED SHEET PHILLIFmm"S P A RT N E R S H I P Ard itectwe - Interiof Design a Planning 770.394.1616 770.394.1314 q J I i C _ F 0 H C A f.' I�rfr2 3 CONSUL TA1`{T Jordan & Skala Engineers, Inc. ?� C3 Project N=ber - 0410070 559 GV --+X" PAWW. li RMSS, GA 30093 AVE (7=7-sst� ftx (n0)446-0262 jie0ft�mscaSa.com arrrrl� Q 2l4 JGf".J.'i ."c SOU ?IGINEERS INC. SEAL �0X, �Q rZ-VISIONS DATE DESCRIPTION L� 1011&&4 SHOPS WHITE BOX rais is tj Phillips Partnership, PC and is cans nra] xr rs7ixr,:nt of Service and is solely for use with res; to r.r ;rajo-:t as indicated below. All rights reserved. iri's=jT-arg r.. f not be reproduced without the prior "roto "&amt of Phillips Partnership, PC. TENANT STANDARD WHITE BOX SHOP 2111 W.P. BALL BOULEVARD PROJECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT r NORTH AMERICAN PROPERTIES NORTH AMERICAN PROPERTIES - ATLANTA 1080 HOLCOMB BRIDGE ROAD BUILDING 200, SUITE 150 ROS'1f_LL, GA 30075 TEL (770) FA5-6566" FAX (770) 643-9540 PHILLIPS JOB TIUMBER 0208616 ISSUE DATE 05/14/04 DRAWN BY/CHECKED BY JMW/RWF DRAWING TITLE WHITE BOX FLOOR PLAN PLUMBING SHEET NUM "e==dam,,,.=- ELECTRICAL SPECIFICATIONS I. SCOPE VOLTAGE:208/120PHASE: 3 WIRE: 4 MOUNTING: SURFACE 4. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE CONNECTED AS INDICATED CKT INSTALL ALL ELECTRICAL WORK COVERED BY THE BELOW SPECIFICATIONS AND 120V. ON THE DRAWINGS. COMMON NEUTRALS AND GROUND WIRES MAY BE LOAD(KVA) APPROVED DRAWINGS. PROVIDE ALL MATERIAL, LABOR, TRANSPORTATION, TOOLS, TRIP POLE PULLED IN CONDUITS WHERE ONLY OPPOSITE PHASE CONDUCTORS ARE HTC KIT MISC SUPERVISION, ETC., NECESSARY TO COMPLETE THE TOTAL ELECTRICAL JOB. ALL KIT RUN. ALL CONDUITS SHALL HAVE A GROUND WIRE PULLED AND SHALL A/C ITEMS NOT SPECIFICALLY MENTIONED HEREIN WHICH ARE OBVIOUSLY NECESSARY TO RCPT COMPLY WITH ARTICLE #250 OF THE NATIONAL ELECTRICAL CODE. 1 MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR, .... ..� I f - .._........ Q - j „ - _ 3 -� c: " Q............ ?.....:... ,.. -� LITHONIA INCLUDING ANY NECESSARY FIELD ENGINEERING AND/OR DETAIL DRAWINGS REQUIRED. 5. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 6 AWG AND LARGER 0.05 DRAWINGS SHALL BE SUBMITTED FOR APPROVAL AS PROVIDED FOR IN "SHOP 1.6 SHALL BE PHASE IDENTIFIED IN EACH ACCESSIBLE ENCLOSURE BY ONE 20/1 DRAWINGS". 3 INCH WIDE PLASTIC TAPE ATTACHED TO CONDUCTORS IN A READILY AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA VISIBLE LOCATION. TAPE COLORS SHALL MATCH COLOR CODE 11. CODES AND FEES REQUIREMENTS SPECIFIED HEREIN. LIGHTS ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST 6. CONNECTIONS BETWEEN FIXTURE JUNCTION BOX AND FIXTURE SHALL BE _ 20/1 RECEPTS. 1.0 EDITION OF THE NATIONAL ELECTRICAL CODE, N.F.P.A. #70, NATIONAL ELECTRICAL MADE WITH NO 16. AWG SILICONE RUBBER INSULATED STRANDED SAFETY CODE, ANSIC-2 AND ALL LOCAL AND STATE CODES AND REGULATIONS. THE EMERGILITE PRO -2 FIXTURE WIRE, TYPE SFF - 2 (150?C.) OR NO. 16 AWG 0.5 CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED 20/1 THERMOPLASTIC, NYLON JACKETED STRANDED FIXTURE WIRE, TYPE THHN 7 BY THE BUILDING AND SAFETY CODES AND ORDINANCES, AND THE RULES AND (90"C.) COLOR CODE AS SPECIFIED HEREIN SHALL NOT BE REQUIRED PRESCOLITE EDS -2 REGULATIONS OF ANY LEGAL BODY HAVING JURISDICTION. FOR FIXTURE WIRE; HOWEVER, NEUTRAL AND GROUND CONDUCTOR SHALL CHLORIDE GM1 WATER HEATER EWH-1 BE IDENTIFIED DISTINCTLY FROM PHASE CONDUCTORS AS PER THE 111. WORKMANSHIP 20/1 RECEPT-SHOW WINDOW 0.4 ABOVE SPECIFICATIONS. 0.5 ALL WORK SHALL BE NEATLY, ORDERLY AND SECURELY INSTALLED WITH CONDUITS, 7. SPLICES IN CONDUCTORS SHALL BE MADE ONLY WITHIN JUNCTION L.E.D. PANELS, BOXES, SWITCHES, ETC., PERPENDICULAR AND/OR PARALLEL WITH THE XA BOXES, WIRING TROUGHS, AND OTHER ENCLOSURES AS PERMITTED BY 20/1 PRINCIPAL STRUCTURAL MEMBERS, AND SHALL BE LEFT IN PROPER WORKING ORDER. 11 THE NATIONAL ELECTRICAL CODE. DO NOT SPLICE CONDUCTORS IN THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF PANELBOARDS, SAFETY SWITCHES, OR MOTOR CONTROL ENCLOSURES. ELECTRICAL EQUIPMENT. COORDINATE DEVICE LOCATIONS WITH DOOR SWINGS, CHLORIDE SPLICES IN CONDUCTORS NO. 10 AWG OR SMALLER SHALL BE MADE WITH SPACE CABINETS, COUNTERS, ETC., AS INDICATED ON THE ARCHITECTURAL DRAWINGS. DO 12 SKOTCHLOK INSULATED SPRING CONNECTORS, IDEAL WRAPPING SPACE NOT SCALE ELECTRICAL PLANS. OBTAIN DIMENSIONS FOR LAYOUT OF EQUIPMENT INSULATED CAPS. SPLICES IN CONDUCTORS NO. 8 AWG AND LARGER LIGHTOLIER LLC2URW OR EQUAL BY FROM ARCHITECTURAL PLANS UNLESS INDICATED ON ELECTRICAL PLANS. 120V., WALL MOUNTED SHALL BE MADE WITH SPLIT BOLT CONNECTORS TAPED WITH NO, 88 POLYCARBONATE, RED LETTERS SPACE PLASTIC ELECTRICAL TAPE UNLESS SPLICES ARE SPECIFICALLY IV. SUBSTITUTIONS PRESCOLITE INDICATED TO BE MADE WITH CRIMPING SLEEVE APPLIED TO 12" ABOVE DOOR FRAME. CONDUCTORS WITH HYDRAULICALLY OPERATED CRIMPING TOOL. ALL COST INCURRED BY THE ACCEPTANCE OF SUBSTITUTIONS SHALL BE BORNE BY THE SPACE 16 CONTRACTOR. PROOF FOR THE EQUALITY OF SUBSTITUTIONS SHALL BE BY THE D. JUNCTION BOXES CONTRACTOR. ALL JUNCTION BOXES SHALL BE CONSTRUCTED OF CODE GAUGE GALVANIZED V. U.L. APPROVAL SHEET STEEL AND COMPLY WITH ARTICLE #314 OF THE NATIONAL ELECTRICAL CODE, FOR THE NUMBER, SIZE AND POSITION OF CONDUITS ENTERING THE ALL ELECTRICAL ITEMS COVERED BY THIS SPECIFICATION SHALL BE U.L. LABELED BOX, SIZE OF BOX AND MAXIMUM NUMBER OF CONDUCTORS IN A BOX. SPACE AND LISTED FOR THEIR SPECIFIC USE. 20 21 SPACE E. PANELBOARDS V1. ELECTRICAL SERVICE SPACE 1. SHALL BE SPECIFIED ON THE DRAWINGS. 23 A. ELECTRICAL SERVICE SHALL BE AS INDICATED ON THE DRAWINGS. SERVICE SHALL ORIGINATE AS SHOWN ON THE DRAWINGS. 2. SHALL BE BOLT -IN CIRCUIT BREAKER TYPE WITH A 100% RATED MAIN BREAKER OR RATED MAIN LUGS ONLY AS NOTED ON DRAWINGS. ALL 24 B. SERVICE CONNECTIONS AT SERVICE POINT SHALL BE MADE BY THE LOCAL SPACE SHALL HAVE U.L. APPROVED INTERRUPTING CAPACITY OF 22,000 AMPS UTILITY COMPANY, THE ELECTRICAL CONTRACTOR SHALL PAY ALL COST MINIMUM UNLESS INDICATED ON DRAWINGS RMS SYM. AT VOLTAGE REQUIRED BY THE LOCAL UTILITY COMPANY PROVIDING SERVICES INDICATED. INDICATED ON DRAWINGS. ALL BUSSING SHALL BE COPPER. ELECTRICAL CONTRACTOR SHALL COORDINATE METERING, TRANSFORMER PAD, 27 SPACE CONNECTION POINTS AND GROUNDING WITH UTILITY COMPANY. 3. SIDE AND GUTTERS SHALL HAVE MINIMUM CODE CLEARANCES. DEPTH SHALL BE 5 3/4" MINIMUM. SPACE C. THE MAIN DISCONNECT AND PANEL SHALL BE LABELED FOR SERVICE ENTRANCE 28 29 SPACED_.. EQUIPMENT. 4. APPROVED MANUFACTURERS ARE: SQUARE D, CUTLER -HAMMER, SIEMENS, AND GENERAL ELECTRIC. VII. TEST 30 31 SPACE- 5. TYPEWRITTEN DIRECTORIES AND PANELBOARD DESIGNATION PLATES A. UPON COMPLETION OF THE WORK, A TEST OF THE INDIVIDUAL SYSTEMS SHALL BE PROVIDED BY THE CONTRACTOR FOR ALL PANELBOARDS. INCLUDING ALL FEEDERS, BRANCHES, OUTLETS, LIGHTING, MOTORS APPARATUS SPACE 32 AND APPLIANCES, TO ASSURE OPERATION IN COMPLIANCE WITH THESE F. LIGHTING FIXTURES Y SPECIFICATIONS AND THE DRAWINGS. A LETTER WITH ALL PERTINENT TEST DATA SHALL BE SUBMITTED TO THE ARCHITECT AT LEAST (5) FIVE DAYS 1. UNLESS INDICATED ON DRAWINGS, BALLASTS PROVIDED WITH FIXTURES PRIOR TO COMPLETION OF PROJECT. 35 SHALL BE ETL-CBM APPROVED, HIGH POWER FACTOR, WITH U.L. LABEL. _ ALL BALLASTS FOR RAPID START LAMPS SHALL BE PREMIUM CLASS P. B. CONTRACTOR SHALL PROVIDE ALL INSTRUMENTS, LABOR AND MATERIALS FOR BALLASTS SHALL BE FOR THE VOLTAGE OF THE CIRCUIT TO WHICH SPACE ANY ESSENTIAL INTERMEDIATE AND FINAL TESTS TO PROVIDE COMPLIANCE 36 CONNECTED. BALLASTS SHALL BE PROVIDED FOR ALL FLUORESCENT AND 50/3 RTU -3A 0.6 WITH THESE SPECIFICATIONS. HIGH INTENSITY DISCHARGE LAMPS. EACH BALLAST SHALL BE 4.0 0.6 PROTECTED BY AN INTERNAL FAST BLOWING FUSE. CONTRACTOR TO VIII. GUARANTEE 60/3 PROVIDE PROPER FUSES. 39 WORK SHALL BE GUARANTEED FOR A ONE (1) YEAR PERIOD. 2. LAMPS SHALL BE PROVIDED FOR ALL FIXTURES IN ACCORDANCE WITH 4.0 FIXTURE SCHEDULE. IX. SPECIFICATIONS ---- -- 40 41 G. WIRING DEVICES A. GROUNDING 4.0 0.6 1. RECEPTACLES AND WALL SWITCHES SHALL BE OF THE TYPE AND SIZE -- 1. SHALL COMPLY WITH ARTICLE #250 OF THE NATIONAL ELECTRICAL CODE LIGHTING: INDICATED 6Y HUBBELL, P&S, OR ARROW HART MAY BE USED. 112,0 10.0 0.0 AND ALL STATE AND LOCAL CODES AND REQUIREMENTS OF THE UTILITY 0.5 0.0 13.5 COMPANY PROVIDING SERVICE AND SHALL BE PROVIDED AS PER THESE 1.9 a. ALL SWITCHES SHALL BE 20 AMP 120 VOLT SPECIFICATION 3.6 SPECIFICATIONS AND THE DRAWINGS. RECEPTACLES: GRADE WITH IVORY HANDLES UNLESS OTHERWISE NOTED. NUMBER CONNECTED LOAD (KVA) OF POLES SHALL BE AS INDICATED ON DRAWINGS. MOTORS: 2. THE BUILDING ELECTRICAL SYSTEMS SHALL BE SOLIDLY GROUNDED 14.2 117.9 SUPPLEMENTED WITH EQUIPMENT CONDUCTORS. ALL NON-CURRENT A/C: b. DUPLEX OUTLETS SHALL BE 20 AMP 125 VOLT A.C. 3 -WIRE 12.2 CARRYING PARTS OF THE ELECTRICAL SYSTEM, I.E., RACEWAYS, SPECIFICATION GRADE STRAIGHT BLADE WITH IVORY FACE, HEATING: EQUIPMENT ENCLOSURES, FRAMES, JUNCTION AND OUTLET BOXES AND 10.7 UNLESS OTHERWISE NOTED ON DRAWINGS. OTHER CONDUCTIVE ITEMS IN CLOSE PROXIMITY WITH ELECTRICAL KITCHEN: 0.0 KVA CIRCUITS, SHALL BE GROUNDED TO PROVIDE A LOW IMPEDANCE PATH 2. DEVICE PLATES SHALL BE IVORY COLORED AND SHALL BE PLASTIC MISCELLANEOUS: FOR POTENTIAL GROUND FAULTS. MIN. PANEL AMPACITY: 105.4 (UNLESS OTHERWISE NOTED ON DRAWINGS). 3. BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTORS ARE NOT SHOWN ON 3, TIME CLOCK SHALL BE PARAGON EL72 OR EQUAL. THE DRAWINGS, HOWEVER, AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL RACEWAYS AND CABLES. H. DISCONNECT SWITCHES B. RACEWAYS 1, DISCONNECT SWITCHES SHALL BE A MINIMUM OF 30 AMP, 250 VOLT RATED, HEAVY DUTY TYPE, 3 POLE WITH SOLID NEUTRAL, UNLESS 1. ALL RACEWAYS (UNLESS NOTED HEREIN) SHALL BE ELECTRICAL OTHERWISE NOTED. METALLIC TUBING (EMT) AND SHALL BE FERROUS GALVANIZED CONDUIT AND SHALL COMPLY WITH ARTICLE #358 OF THE NATIONAL ELECTRICAL CODE OR BE INTERMEDIATE METAL CONDUIT (IMC) AND SHALL BE FERROUS GALVANIZED CONDUIT AND SHALL COMPLY WITH ARTICLE #342 OF 'THE NATIONAL ELECTRICAL CODE OR BE RIGID STEEL CONDUIT AND SHALL COMPLY WITH ARTICLE #344 OF THE NATIONAL ELECTRICAL CODE. EMT COUPLINGS SHALL BE STEEL SET SCREW TYPE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM JUNCTION BOXES TO CORRESPONDING RECESSED LIGHTING FIXTURES AND SHALL COMPLY WITH ARTICLE #348 OF THE NATIONAL ELECTRICAL CODE. 3. LIQUID TIGHT FLEXIBLE METAL OR NON-METALLIC CONDUIT SHALL BE USED FROM OUTDOOR EXPOSED CONNECTIONS TO GROUND OR ROOF MOUNTED EQUIPMENT AND COMPLY WITH ARTICLE #350 OF THE NATIONAL ELECTRICAL CODE. 4. RIGID NONMETALLIC CONDUIT SHALL BE PVC SCHEDULE 40 AND SHALL COMPLY WITH ARTICLE #352 OF THE NATIONAL ELECTRICAL CODE. RIGID NON-METALLIC CONDUIT MAY BE USED FOR SERVICE ENTRANCE, IF ALLOWED BY LOCAL CODE AUTHORITY AND INSTALLED PER THE NATIONAL ELECTRICAL CODE. 5. ALL RACEWAYS SHALL BE INSTALLED CONCEALED EXCEPT IN UNFINISHED SPACES OR WHERE INDICATED. C. CONDUCTORS 1. ALL CONDUCTORS SHALL BE COPPER AND HAVE 600 VOLT TYPE, 90°C, THHN/THWN INSULATION EXCEPT WHERE NOTED ON THE DRAWINGS. 2. ALL BRANCH CIRCUITS SHALL BE MINIMUM OF #12 AWG SOLID COPPER EXCEPT FOR MOTOR LEADS, WHICH SHALL BE A MINIMUM OF #12 AWG STRANDED COPPER, UNLESS OTHERWISE NOTED ON DRAWINGS. 3. ALL BRANCH CIRCUIT AND FEEDER CONDUCTORS, NO. 8 AWG AND SMALLER, SHALL BE COLOR CODED AS FOLLOWS: 120/208 VOLT SYSTEM PHASE A - BLACK PHASE B - RED PHASE C - BLUE NEUTRAL - WHITE GROUND - GREEN WHITE BOX FLOOR PLAN - SUITE 21 11 - ELECTRICAL SCALE: 1/8" = V-0" PANELBOARD SCHEDULE - L DI MAINS: 225A MLO VOLTAGE:208/120PHASE: 3 WIRE: 4 MOUNTING: SURFACE AIC: 10,000 NOTES.. CKT TRIP DESCRIPTION LOAD(KVA) POS LTG RCPj MTR A/C 120V. PHASE A B C LOAD(KVA) DESCRIPTION TRIP POLE CKT # HTC KIT MISC MISC KIT HTC A/C MTR RCPT LTG 1 20/1 RECEPT-TELEP. BKBD 1.0_--- .... ..� I f - .._........ Q - j „ - _ 3 -� c: " Q............ ?.....:... ,.. -� LITHONIA B 0.05 LIGHTOLIER LSW2217-120-SO OR EQUAL BY 1.6 LIGHTS 20/1 2 3 20/1 RECEPTS. 0.6 AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA COLUMBIA 1.5 LIGHTS 20/1 4 5 _ 20/1 RECEPTS. 1.0 LITHONIA 6 VOLT TWIN -HEAD BATTERY LIGHT, EMERGILITE PRO -2 INCLUDED 0.5 NIGHT EMERGENCY LIGHTS 20/1 6 7 20/1 RECEPTS. 0.8 PRESCOLITE EDS -2 1.5 CHLORIDE GM1 WATER HEATER EWH-1 20/1 8 9 20/1 RECEPT-SHOW WINDOW 0.4 0.5 COMBINATION EXIT/EMERGENCY, LIGHTOLIER LLC2URW-PENDANT OR EQUAL BY L.E.D. 120V., PENDANT MOUNTED XA FACP 20/1 10 11 SPACE PRESCOLITE 9'-6" AFF. CHLORIDE SPACE 12 13 SPACE COMBINATION EXIT/EMERGENCY, LIGHTOLIER LLC2URW OR EQUAL BY L.E.D. 120V., WALL MOUNTED XB POLYCARBONATE, RED LETTERS SPACE 14 15 SPACE PRESCOLITE 12" ABOVE DOOR FRAME. CHLORIDE SPACE 16 17 SPACE- SPACE 18 19 SPACE SPACE 20 21 SPACE SPACE 22 23 SPACESPACE 24 25 SPACE SPACE 26 27 SPACE SPACE 28 29 SPACED_.. SPACE 30 31 SPACE- SPACE 32 33 SPACE Y SPACE 34 35 SPACE _ SPACE . 36 37 50/3 RTU -3A 0.6 4.0 4.0 0.6 RTU -3B 60/3 36 39 -- ---- 4.0 4.0 0.6 ---- -- 40 41 -- ---- LO. 4.0 4.0 0.6 -___ -- 42 LIGHTING: 3.6 0.0 3.8 0.0 112,0 10.0 0.0 0.5 0.0 13.5 0.0 1.9 0.0 3.6 TOTAL CONNECTED LOAD: 3.7.1 RECEPTACLES: 3.8 CONNECTED LOAD (KVA) CONNECTED LOAD (KVA) TOTAL DEMAND LOAD: 37.1 MOTORS: 3,7 PHASE A 14.2 117.9 A/C: 0.0 PHASE B 12.2 101.7 CONNECTED LOAD (AMPERES): 102.9 HEATING: 25,5 PHASE C 10.7 89.2 DEMAND LOAD (AMPERES): 102.9 KITCHEN: 0.0 KVA AMPS MISCELLANEOUS: 0.5 MIN. PANEL AMPACITY: 105.4 10 PROVIDE LOCK -ON DEVICE LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER CATALOG NO. LAMPS NOTES A 2' X 4', 4 -LAMP RECESSED ACRYLIC LENS LIGHTOLIER XP2GVA43212004 OR EQUAL BY 4-F32T8/SP35 120V. INCLUDED W/UNIT TROFFER, WITH ELECTRONIC BALLAST, GRID METALUX 208V/30 LD1 -38 3#6,1#1 OG -1"C. TYPE. COLUMBIA EWH-1 120V/10 LD1 -8 2#12,1#12G -1/2"C. DAYBRITE ABOVE CEILING LITHONIA B 2', 2 -LAMP WALL MTD FIXTURE WITH LIGHTOLIER LSW2217-120-SO OR EQUAL BY 2-F17T8/SP35 120V. BOX SHOP ACRYLIC LENS, ELECTRONIC BALLAST. METALUX THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA COLUMBIA DAYBRITE LITHONIA 6 VOLT TWIN -HEAD BATTERY LIGHT, EMERGILITE PRO -2 INCLUDED 120V. E SURFACE MOUNTED, SURELITES CC -2 PRESCOLITE EDS -2 CHLORIDE GM1 LITHONIA ELM2 COMBINATION EXIT/EMERGENCY, LIGHTOLIER LLC2URW-PENDANT OR EQUAL BY L.E.D. 120V., PENDANT MOUNTED XA POLYCARBONATE, RED LETTERS SURELITES WITH CENTER OF FIXTURE PRESCOLITE 9'-6" AFF. CHLORIDE LITHONIA COMBINATION EXIT/EMERGENCY, LIGHTOLIER LLC2URW OR EQUAL BY L.E.D. 120V., WALL MOUNTED XB POLYCARBONATE, RED LETTERS SURELITES WITH CENTER OF FIXTURE PRESCOLITE 12" ABOVE DOOR FRAME. CHLORIDE LITHONIA C0 10 KEY NOTES: 0 24" X 24" X 3/4" PAINTED PLYWOOD TELEPHONE BACKBOARD. EXTEND 1" EMPTY CONDUIT TO LANDLORD'S TELEPHONE CABINET. V JUNCTION BOX MOUNTED AT STOREFRONT FOR TENANT SIGN POWER. COORDINATE EXACT JUNCTION BOX LOCATION AND MOUNTING HEIGHT WITH ARCHITECT'S ELEVATION PRIOR TO ROUGH -IN. EXTEND 3/4" EMPTY CONDUIT WITH PULL WIRE TO TENANT PANEL AND TERMINATE. O DUPLEX RECEPTACLE MOUNTED FLUSH IN CEILING TILE ABOVE SHOW WINDOW. ® NEW METER AND SERVICE ENTRANCE DISCONNECT SWITCH. REFER TO ELECTRICAL RISER DIAGRAM 2/RE1.3A FOR ADDITIONAL INFORMATION. REFER TO SITE PLAN EO.1 FOR FEEDER CONTINUATION AND UTILITY CO. TRANSFORMER LOCATION. O ROOF MOUNTED CA RECEPTACLE PROVIDED WITH ROOF TOP MECHANICAL UNIT. ELECTRICAL CONTRACTOR SHALL EXTEND TO CIRCUIT NOTED IN TENANT PANEL. 06 NUMBER ADJACENT TO DEVICE OR FIXTURE DENOTES CIRCUIT BREAKER DEVICE OR FIXTURE IS SERVED FROM IN TENANT PANEL. O7 FIXTURE NOTED WITH "NL" SHALL BE A NIGHTLIGHT THAT OPERATES 24 HRS., CIRCUIT WITH EMERGENCY LIGHTS AS SHOWN. FIRE ALARM CONTROL PANEL. EXTEND 2#12,1#120-1/2"C. TO CIRCUIT LD1 -10. MECHANICAL EQUIPMENT CONNECTION SCHEDULE DESCRIPTION VOLTAGE CIRCUIT CONDUCTORS DISCONNECT NOTES RTU -3A 208V/30 LDl-37 3#6,1#10G -1"C. INCLUDED W/UNIT ON ROOF RTU -3B 208V/30 LD1 -38 3#6,1#1 OG -1"C. INCLUDED W/UNIT ON ROOF EWH-1 120V/10 LD1 -8 2#12,1#12G -1/2"C. 30/2/1 ABOVE CEILING Trus 3 r' r-4•.i8:?s 7ortnership, PC and is conr.eit.9 :n c<rrrcrtrt of Str,:ce and is solely for use with respect t2 _'s ;sojY_s cs :r.62 t -_J row. All righty reserved. This lx�xr •A iJf r.R R rt;(Odled 'without the prior .rata -vw4vA d Ptigps Partnership, PC. TENANT STANDARD WHITE BOX SHOP REVISION # 34 SUMMARY A. ADDED SHEET Elm PHI LL11mwS P A R T N E R S H I P AroiYtecture • Interior Design • Planning 770.394.1616 F- 770.394.1314 �c J t r E F G H C - c o CONSU! TAtff Jordan & Skala Engineers, Inc. Pt9ject N=ber • 0410070 5365 JIC:F" ?A -KW. . 16KROSS, GA 30093 A*f F_ (7M}iS7-5547 DX (770446-0262 riiL• rx4�r5�rBicala.com CC1PfiWn7 A fJ4 JCFSi.K j SKU ENGINEERS INC. O REVISIONS 9 DATE DESCRIPTION L& 10/18/04 SHOPS WHITE BOX Trus 3 r' r-4•.i8:?s 7ortnership, PC and is conr.eit.9 :n c<rrrcrtrt of Str,:ce and is solely for use with respect t2 _'s ;sojY_s cs :r.62 t -_J row. All righty reserved. This lx�xr •A iJf r.R R rt;(Odled 'without the prior .rata -vw4vA d Ptigps Partnership, PC. TENANT STANDARD WHITE BOX SHOP 2111 W.P. BALL BOULEVARD PROJ ECT THE MARKETPLACE AT SEMINOLE TOWNE CENTER 0 SANFORD, FLORIDA CLIENT NORTH AMERICAN! PROPERTIES NORTH AMERICV1 PROPERTIES - ATLANTA 1080 HO! COMB BRIDGE ROAD BUI! DRIG 200, SUITE 150 ROSY[EI E, GA 30075 TEL (770) 645-6578 FAX (770) 643-9540 ?HILLIPS JOB NUMBER 0208616 ISSUE DATE 05/14/04 DRAWN BY/CHECK_D BY AWO/CCJ DRAWING TITLt WHITE T BOX FLOOR PLAN ELECTRICAL SHEET NUMBER I El t