Loading...
HomeMy WebLinkAbout401 Bella Rosa CirCITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: t U— ( � 1-0--- Documented Construction Value: ` L- �S_uU Job Address: LV) V\`3 .t1c� �` t� u- (" Parcel D): c V tok _ 7z 1 - ,0 t'yjrrs�6 --n'-(co k1 Description of Work: __—_tVtm L Plan Review Contact Person: Phone:L(%q l CS JA('0 Fax: Historic District: Yes ❑ No ❑ Zoning: Title: I"Ii^ _\- j�p2 E-mail: I Property Owner Information Name i��L1�1y�tF-tel �Vi S L�C� Street; `G \ •` lt.�����G �� i�r� _�17 City, State Zip: Phone: Resident of property? Contractor Information Name r_�� _( � �C� i� ��{ � l ') � �t_L Phone: Street: ����� !J 0o1ki-�N\-0- e Fax: City, State Zip: �,l � k State License No. FL_ Information Nance: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage =Lender; Address: PERMIT INFORMATION Building Permit ❑� Square Footage: Construction Type: �« , No. of Storks: No. of Dwelling Units: i Flood Zone: Electrical ❑ Plumbing El-'"-' New Service - No. of AMPS:- New Construction - No. of Fixtures: Mechanical 11 (Duct layout required for new systems') Fire SprinklerlAlartn 11 No. of heads: STRUCTURAL LOAD LIMITATIONS: DESIGN CODES FLORIDA BUILDING CODE 2004 ASCE 7-02 CODE BUILDING DEAD LOADS A. ROOF = 25 PSF B. FLOOR= 10 PSF C. WALLS= 5PSF BUILDING LIVE LOADS A. ROOF = 30 PSF B. FLOOR= 50/100 =2000# CONCENTRATED LOAD. C. CORRIDOR= 100 PSF OVER 30 INCH C 20 INCH AREA LOCATED ANYWHERE ON FLOOR. ROOF SNOW LOAD: N/A WIND LOAD CRITERA: 1. 130 MPH WIND SPEED 2 1 w = 1.0 WIND IMPORTANCE FACTOR. 3. II BUILDING CATEGORY 4. ENCLOSURE CLASSIFICATION: ENCLOSED GCpI =0.18 INTERNAL PRESSURE COEFFICIENT. 5. C EXPOSURE FACTOR 6. 0.85 WIND DIRECTIONALITY FACTOR (Kd) 7. 0.85 GUST RESPONSE FACTOR (Gh) 8. MAINFRAME STRUCTURE OVERTURNING LOAD Pr = -93 PSF 9. COMPONENT & CLADDING LOAD: (ROOF) Pr = 123,70 PSF ( WALL ) PW = 55.6 PSF ZONE 5 PW = 40 ZONE 4 . 10. ENCLOSED BUILDING ENCLOSURE CLASSIFICATION 11. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT ON THE UPPER HALF OF A HILL OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT. SEISMIC LOAD: N/A FLOOD LOAD: THIS BUILDING IS NOT DESIGNED TO BE SUBMERGED OR SUBJECTED TO WAVE ACTION WHEN LOCATED IN A FLOOD PRONE OR ZONE AREA. FINISH FLOOR ELEVATION MUST BE LOCATED ABOVE THE BUILDING SITE FLOOD PLANE LEVEL. MECHANICAL NOTES: 1. ALL SUPPLY AIR REGISTERS SHALL BE 10 INCHES X 10 INCHES ADJUSTABLE w / 10 INCHES X 20 INCHES (INSIDE) OVERHEAD FIBERGLASS DUCT, UNLESS OTHERWISE SPECIFIED, DUCTS LOCATED IN VENILATED ATTIC SPACES SHALL HAVE AN R-6 INSULATION VALUE. DUCTS LOCATED IN UNCONDITIONED INTERIOR SPACE. INTERIOR SPACES SHALL HAVE AN R-4.2 INSULATION VALUE. 2. RESTROOM VENT FANS SHALL PROVIDE 50 CFM MINIMUM PER WATER CLOSET AND / OR URINAL. 3. VENT FANS SHALL BE DUCTED TO THE EXTERIOR AND TERMINATE AT AN APPROVED VENT CAP. 4. HVAC EQUIR*"T"SHALL BE EQUIPPED WIYH OUTSIDE FRESH INTAKES PROVIDING 20 CFM FOR EACH OCCUPANT OR 50 CFM FOR EACH WATER HEATER CLOSET AND EACH URINAL, WHICH EVER IS GREATER. PLUMBING NOTES: 1. CUSTOMER ASSUMES ALL RESPONSIBILITY FOR DRINKING WATER FACILITIES AND SERVICE SINK WHEN NOT SHOWN ON THE FLOOR PLAN. 2. TOILETS SHALL BE ELONGATED WITH NON-ABSORBENT OPEN FRONT SEAT. 3. RESTROOMS WALLS SHALL BE COVERED WITH NON-ABSORBENT MATERIAL TO A MINIMUM HEIGHT OF 48 INCHES A.F.F. 4. ALL PLUMBING FIXTURES SHALL HAVE SEPARATE SHUT-OFF VALVES, 5. WATER HEATER SHALL HAVE SAFTY PAN WITH 1 INCH DRAIN TO EXTERIOR, T & P RELIEF VALVE WITH DRAIN TO EXTERIOR, AND A SHUT OFF VALVE WITHIN 3 FEET ON A COLD WATER SUPPLY LINE. 6. DWV SYSTEM SHALL BE EITHER ABS OR PVC - DWV. 7. WATER SUPPLY LINES SHALL BE POLYBUTYLLENE, CPVC, OR COPPER; WHEN POLYBUTYLENE SUPPLY LINES ARE INSTALLED THE MAXIMUM WATER HEATER TEMPERATURE SETTING IS 180° F. THE POLY- BUTYLENE PIPE SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES LIMITATIONS AND INSTRUCTIONS. 8. WATER CLOSETS ARE TANK TYPE AND URINALS ARE FLUSH TANK TYPE UNLESS OTHERWISE SPECIFIED. 9. BUILDING DRAIN AND CLEANOUTS ARE DESIGNED AND SITE INSTALLED BY OTHERS. SUBJECT TO LOCAL JURISDICTION APPROVAL 10. SHOWERS SHALL BE CONTROLLED BY AN APPROVED MIXING VALVE WITH A MAXIMUM WATER OUTLET TEMPERATURE OF 120° F (48.8° C ). 11. THERMAL EXPANSION DEVICE, IF REQUIRED BY WATER HEATER INSTALLED, AND IF NOT SHOWN ON PLUMBING PLAN, IS DESIGNED AND SITE INSTALLED BY OTHERS, SUBJECT TO LOCAL JURISDICTION AND APPROVAL, AS -BUILT BUILDING NOTES: RELOCATION OF THIS BUILDING IS SUBJECT TO THE APPROVAL OF THE LOCAL JURISDICTION THESE PLANS HAVE NOT BEEN PREPARED BASED ON THE CURRENT CODES, BUT THE CODES THAT WERE IN EFFECT AT THE TIME OF INITIAL CONSTRUCTION. THE ARCHITECT OR ENGINEERS ARE NOT RESPONSIBLE FOR ANY DAMAGE TO OR . ALTERATOINS IN THE BUILDING, BUILDING DESIGN, OR CODE REVISIONS THAT WERE MADE AFTER THE INITIAL APPROVAL OF THE BUILDING. IF THE STATE LABEL HAS BEEN LOST, REMOVED OR STOLEN THEN IT UP TO THE LOCAL JURISDICTION TO REVIEW AND APPROVE THE ATTACHED BUILDING PLANS. THIS IS A SET OF STOCK AS -BUILT APPROVED BUILDING PLANS. THE ORIGINAL SET OF APPROVED PLANS IS NO LONGER AVAILIABLE, THEREFORE THIS SET HAS BEEN PROVIDED FOR ACQUIRING A BUILDING PERMIT. off+= GENERAL NOTES: 1. ACCESS TO BUILDING FOR PERSONS IN WHEELCHAIRS IS DESIGNED BY AND FIELD BUILT BY OTHERS AND SUBJECT TO ALL LOCAL JURISDICTIONS. AT LEAST 50% OF PUBLIC ENTRANCES (INCLUDUNG PRIMARY ENTRANCE) AND ALL REQUIRED EXITS MUST BE ACCESSABLE. 2. ALL DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFORT. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BLOTS SHALL NOT BE USED. 3. ALL GLAZING WITHIN A 48 INCH ARC OF DOORS, WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR, AND ALL GLAZING IN DOORS SHALL BE SAFTY, TEMPERED OR ACRYLIC PLASTIC SHEET. 4. FLOOR DESIGN LIVE LOAD -100 PSF ( LOBBIES & CORRIDORS); 50 PSF( REMAINDER ). 5. MAXIMUM WIND LOAD -130 MPH ( EXP. C) 6. OCCUPANCY IS BUSINESS. 7. OCCUPANT LOAD: 7 PEOPLE. [ BASED ON 1 PERSON PER 100 SQUARE FEET OF BUSINESS AREA). 8. CONSTRUCTION IS TYPE V - B, UNPROTECTED. 9. ALL STEEL STRAPS REFERENCED ON FLOOR PLAN SHALL BE 1.5 INCH X 26 GA. W/ (8) 15 GA. X 7/16 INCH CROWN X 1 1/2 INCH STAPLES WITH A MINIMUM OF 1" PENETRATION EACH END OF STRAP OR 10. MINIMUM COORIDOR WIDTH IS 44 INCHES. 11. MINIMUM CORRIDOR FINISH IS CLASS B (GYPSUM). 12. WINDOW AND DOOR HIGH WIND STORM COVERINGS PER CODE TO BE SUPPLIED AND SITE INSTALLED BY OTHERS SUBJECT TO LOCAL JURISDICTION AND APPROVAL. 13. PLAN REVIEW AND INSPECTION REQUIRED BY CHAPTER 633 F.S. TO BE DONE BY THE LOCAL FIRE SAFETY INSPECTOR. 14. PORTABLE FIRE EXTINGUISHER PER N.F.P.A.-101 INSTALLED BY OTHERS ON SITE, AND SUBJECT TO LOCAL JURISDICTION AND APPROVAL. 15 THIS BUILDING REQUIRES A FIRE SEPARATION DISTANCE OF GREATER THAN OR EQUAL TO 30 FEET. 16. WHEN LOW SIDE OF ROOF PROVIDES LESS THAN 6" OF OVERHANG GUTTERS AND DOWNSPOUTS WILL BE REQUIRED, SITE INSTALLED AND SUBJECT TO LOCAL JURISDICTION. 17. IN WIND BORNE DEBRIS REGIONS, EXTERIOR GLAZING SHALL BE PROTECTED WITH AND IMPACT RESISTANT COVERING OR WITH MINIMUM 7/16" WOOD STRUCTURAL PANELS PER SECTION 1609.1.4 OF THE FBC. PANELS SHALL BE PRECUT TO COVER THE GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED PER TABLE 1 609.1.4 THE IMPACT RESISTANT COVERING OR WOOD STRUCTURAL PANELS ARE TO BE PROVIDED ON SITE BY THE BUILDING OWNER SUBJECT TO LOCAL JURISDICTION AND APPROVAL. WIND BORNE DEBRIS REGIONS ARE AREAS WITHIN ONE MILE OF THE COASTAL MEAN HIGH WATER LINE` WHERE THE BASIC WIND SPEED IS 110 MPH OR GREATER AND AREAS WHERE THE BASIC WIND SPEED IS 120 MPH OR GREATER. 18. ALL MATERIALS USED IN THE CONSTRUCTION OF THE BUILDING WHICH ARE COVERED BY THE FLORIDA BUILDING COMMISSION CHAPTER 913- 72 RULES SHALL HAVE CURRENT FLORIDA PRODUCT APPROVAL,, 19. THESE PLANS COMPLY WITH THE 2004 FBC w / 2005 and 2006 AMMENDS. 20. THE RAISED SEAL SET OF PLANS ARE ON FILE IN THE THIRD PARTY AGENCY'S OFFICE AS DIRECTED BY DCA. 21. EMERGENCY LIGHTING SHALL BE CAPABLE OF PROVIDING INITIAL ILLUMINATION THAT IS ATLEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MIN. OF .1 FC MEASURED ALONG THE EGRESS AT THE FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO .6 C AVERAGE AND A MINIMUM AT ANY POINT OF .06 FC AT THE END OF THE EMERGENCY LIGHT TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION, UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES. ELECTRICAL NOTES: 1. ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE APPROPRIATE ARTICLES OF THE NATIONAL ELECTRICAL CODES (NEC). 2. WHEN LIGHT FIXTURES ARE INSTALLED IN CLOSETS THEY SHALL BE SURFACE MOUNTED OR RECESSED. INCANDESCENT FIXTURES SHALL HAVE COMPLETELY ENCLOSED LAMPS. SURFACEMOUNTED INCANDESCENT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 12 INCHES AND ALL OTHER FIXTURES SHALL HAVE A MININMUM CLEARANCE OF 6 INCHED FROM " STORAGE AREA" AS DEFINED BY NEC 410-8 (a) 3. WHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE WATER HEATERS SERVED. THE BRANCH CIRCUIT SWITCH OR CIRCUIT BREAKER SHALL BE PERMITTED TO SERVE AS THE DISCONNECTING MEANS ONLY WHERE THE SWITCH OR CIRCUIT BREAKER IS WITHIN SIGHT FROM THE WATER HEATER OR CAPABLE OF BEING LOCKED IN THE OPEN POSION. 4. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE EQUIPMENT SERVED. A UNIT SWITCH WITH A MARKED " OFF " POSITION THAT IS A PART OF THE HVAC EQUIPMENT AND DISCONNECTS ALL UNGROUNDED CONDUCTORS SHALL BE PERMITTED AS THE DISCONNECTING MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A READILY ACCESSIBLE CIRCUIT BREAKER. 5. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING OF THE MAIN BREAKER MUST BE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE WITH SECTION 110-9 OF THE NEC BY LOCAL ELECTRICAL CONSULTANT. 6. THE MAIN ELECTRICAL PANEL AND FEEDERS ARE DESIGNED BY OTHERS, SITE INSTALLED AND SUBJECT TO LOCAL JURISDICTION APPROVAL 7. ALL CIRCUITS CROSSING OVER MODULE MATING LINE(S) SHALL BE SITE CONNECTED WITH APPROVED ACCESSIBLE JUNCTION BOXES OR CABLE CONNECTORS. 8. REFERENCE STATE APPROVED PACKAGE FOR ELECTRICAL RISER DIAGRAM. 9. FIRE ALARM PULL STATION OPERABLE DEVICE SHALL BE LOCATED 42 TO 45 INCHES ABOVE THE FLOOk. FIRE ALARM HORN / STROBE DEVICE SHALL BE WALL MOUNTED WTH THE BOTTOM EDGE 80 INCHES ABOVE THE FLOOR. 10. EXTERIOR LIGHTS NOT INTENDED FOR 24 HOUR USE AND SHALL BE CONNECTED TO A PHOTOCELL OR TIMER. 11. ALL RECEPTICALS INSTALLED IN WET LOCATIONS (EXTERIOR) SHALL BE IN WEATHER PROOF (W.P.) ENCLOSURES. THE INTEGRITY OF WHICH IS NOT AFFECTED WHEN AN ATTACHMENT PLUG CAP IS INSERTED OR REMOVED. 12. WHEN NOT SHOWN ON THE PLANS PROVISIONS FOR EXIT DISCHARGE LIGHTING (INCLUDING EXIT DISCHARGE EMEGENCY LIGHTING) ARE DESIGNED BY OTHERS AND THE RESPONSIBILITY OF THE BUILDINGS OWNER AND SUBJECT TO LOCAL JURISDICTION APPROVAL. ACCESSIBILITY NOTES: 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL ACCESSIBILE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBILE ENTRANCE. 2. ACCESSIBLE DRINKING FOUNTAINS SHALL HAVE A SPOUT HEIGHT NO HIGHER THAN 36 INCHES ABOVE THE FLOOR AND EDGE OF BASIN NO HIGHER THAN 34 INCHES ABOVE THE FLOOR FOR INDIVIDUALS IN WHEEL- CHAIRS. ADDITIONALLY, DRINKING WATER PROVISIONS SHALL BE MADE FOR INDIVIDUALS WHO HAVE DIFFICULTY IN BENDING. 3. WHERE STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS, AND DRAWERS ARE PROVIDED AT LEAST ONE OF EACH TYPE PROVIDED SHALL CONTAIN STORAGE SPACE COMPLYING WITH THE FOLLOWING: DOORS, ETC. TO SUCH SPACES SHALL BE ACCESSIBLE (ie. TOUCH LATCHES, U -SHAPED PULLS): SPACES SHALL BE WITHIN 15 INCHES MINIMUM AND 48 INCHES MAXIMUM OF THE FLOOR FOR FORWARD REACH OR 9 INCHES MINIMUM AND 54 INCHES MAXIMUM, OF THE FLOOR FOR SIDE REACH; CLOTHES RODS SHALL BE A MINIMUM OF 54 INCHES ABOVE THE FLOOR (48 INCHES MAXIMUM WHEN DISTANCE FROM WHEELCHAIR TO ROD EXCEEDS 10 INCHES). 4. CONTROLS, DISPENSERS, RECEPTACLES AND OTHER OPERABLE EQUIPMENT SHALL BE NO HIGHER THAN 45 INCHES ABOVE THE FLOOR FOR FRONT APPROACH OR 54 INCHES ABOVE THE FLOOR FOR SIDE APPROACH. RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15 INCHES ABOVE THE FLOOR. EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR' WHERE ELECTRICAL RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. 5. WHERE EMERGENCY WARING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED 80 INCHES ABOVE THE FLOOR OR 6 INCHES BELOW CEILING, WHICHEVER IS LOWER. 6. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (ie. LEVER - OPERATED, PUSH - TYPE, U - SHAPED) MOUNTED NO HIGHER THAN 48 INCHES ABOVE THE FLOOR. 7. ALL DOORS SHALL BE OPENABLE BY A SINGLE EFFORT, THE MAXIMUM FORCE REQUIRED TO OPEN A DOOR SHALL NOT EXCEED 8.5 LBS. FOR EXTERIOR SWINGING DOORS AND 5 LBS. FOR ALL SLIDING, FOLDING, AND INTERIOR SWINGING DOORS. 8. FLOOR SURFACES SHALL BE STABLE, FIRM, AND SLIP-RESISANT. CHANGES IN LEVEL BETWEEN 0.25 INCHES AND 0.5 INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, CHANGES IN LEVEL GREATER THAN 0.5 INCH REQUIRE RAMPS. CARPET PILE THICKNESS SHALL BE 0.5 INCH MAX. GRATINGS IN FLOOR SHALL HAVE SPACES NO GREATER THAN 0.5 INCH WIDE IN ONE DIRECTION. DOORWAY THRESHOLDS SHALL NOT EXCEED 0.5 INCH IN HEIGHT. 9. ACCESSIBILE WATER CLOSETS SHALL BE 19 INCHS FROM THE FLOOR TO THE TOP OF THE SEAT. GRAB BARS SHALL BE 36 INCHES LONG MINIMUM WHEN LOCATEDBEHIND THE WATER CLOSET AND 42 INCHES MININUM WHEN LOCATED ALONG THE SIDE OF THE WATER CLOSET, AND SHALL BE MOUNTED 33 INCHES FROM THE FLOOR TO THE TOP OF THE RAIL WITH 0.5 INCH MAXIMUM VARIATION. 10. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17 INCHES ABOVE THE FLOOR. 11. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29 INCHES ABOVE THE FLOOR TO THE BOTTOM OF THE APRON. 12. ACCESSIBLE SINKS SHALL BE MOUNTED WITH RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 27 INCHES HIGH, 30 INCHES WIDE, AND 19 INCHES DEEP UNDERNEAT SINK. THE SINK DEPTH SHALL BE 6.5 INCHES MAXIMUM. 13. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT CONTACT, INSULATION OR PROTECTION MATERAL MAY BE SITE INSTALLED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER ACCESSIBLE LAVATORIES AND SINKS. 14. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS (ie. LEVER- OPERATED, PUSH -TYPE, ELECTRONICALLY CONTROLLED). 15 WHERE MIRRORS ARE PROVIDED IN RESTROOM, AT LEAST ONE SHALL BE PROVIDED WITH ITS BOTTOM EDGE NO HIGHER THAN 40 INCHES ABOVE THE FIOOR. 16 WHERE MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES ABOVE THE FLOOR. 17. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.25 INCHES TO 1.5 INCHES IN DIAMETER WIRH 1.5 INCHES CLEAR SPACE BETWEEN THE BAR AND THE WALL. 18. TOILET STALL DOORS SHALL BE THE SELF-CLOSING TYPE. 19. A TOWEL DISPENCER SHALL BE LOCATED ADJACENT TO ALL ACCESSIBLE LAVATORIES. 20. WATER CLOSET FLUSH CONTROL SHALL BE MOUNTED ON THE WIDE SIDE OF THE CLOSET. SITE INSTALLED NOTES: NOTE THAT THIS LIST DOES NOT NECESSARILY LIMITS THE ITEMS OF WORK AND MATERIALS THAT MAY BE REQUIRED FOR A COMPLETE INSULATION. ALL SITE RELATED ITEMS ARE SUBJECT TO LOCAL JURISDICTION AND APPROVAL. 1. THE COMPLETE FOUNDATION SUPPORT AND TIE DOWN SYSTEM. 2. RAMPS, STAIRS AND GENERAL ACCESS TO THE BUILDING. 3. PORTABLE FIRE EXTINGUISHERS (S). 4. DRINKING FOUNTAIN, BUILDING DRAINS, CLEAN -OUTS, AND HOOK- UP TO PLUMBING SYSTEM. 5. ELECTRICAL SERVICE HOOK-UP ( INCLUDING FEEDERS) TO THE BUILDING. 6. THE MAIN ELECTRICAL PANEL AND SUB -FEEDERS ( MULTI -UNITS ONLY). 7. CONNECTION OP ELECTRICAL CIRCUITS CROSSING OVER MODULE MATING LINES (S) - ( MULTI -UNITS ONLY). 8. STRUCTURAL AND AESTHETIC INTERCONNECTIONS BETWEEN 9. WINDOW AND DOOR HIGH WIND STORM COVERINGS PER CODE. 10. GUTTERS AND DOWNSPOUTS (IF APPLICABLE). 11. SINK AND CABINETS. 12. FIRE ALARM SYSTEM, WIRING, ETC. 13. THERMAL EXPANSION DEVICE IF REQUIRED. STATE CODES: FLORIDA 2007 FLORIDA BUILDING CODE 2004 FPC w/ 2005/2006 AMENDS 2004 FMC w/ 2005/2006 AMENDS 2003 NFPA 101 2008 NEC FACBC 2004 FFPC OCCUPANCY B CONSTRUCTION TYPE V - B DRAWING INDEX: Cl COVER SHEET Al FLOOR PLAN A2 ELEVATIONS A3 BUILDING CROSS SECTION ,,,�► A4 FOUNDATION PLAN ELEVATION NOTES (TYP.) W 1.) SEE CROSS SECTION FOR METHOD OF ROOF VENTILATION 2.) HANDICAP RAM(S), STAIRS (S), AND HANDRAILS ARE TO BE DESIGNED AND SITE INSTALLED BY OTHERS, SUBJECT TO LOCAL JURISDICTION AND APPROVAL. 3.( FOUNDATION ENCLOSURE ( WHEN PROVIDED) MUST HAVE 1 SQUARE FOOT NET VENT AREA PER 1/1 1/150th OF THE FLOOR AREA, AND AN 18" X 24" MINIMUM F` CRAWL SPACE ACCESS, SITE INSTALLED BY OTHERS, SUBJECT TO LOCAL JURISDICTION AND APPROVAL. 0 REVISION DATE: DATE: 04/28/2009 DRAWN: R.C.S. JOB #: STOCK UNIT SHEET NO. cl Q COPYRIGHT 2007 -MODULAR PLANS DESIGN, CO. NOTICELo PLEASE REVIEW PLANS COMPLETELY, ANY COMPONENTS CROSSING MATE, LINES WILL v) CI, BE SITE INSTALLED BY SET UP CREW. � IN < O �-- Z) 0 �/ O , TL3' p P E, 1 IM REVISION DATE: DATE: 04/28/2009 DRAWN: R.C.S. JOB #: STOCK UNIT SHEET NO. cl Q COPYRIGHT 2007 -MODULAR PLANS DESIGN, CO. tnu ,ccwt i� i 4 r i . FROM EACH M. STUDS 56, SET 12" O.C. (tgplcal) EM AY WAC tKW +'7 2 m RR EMAX I!ODEI.: X65 ., ...., , 2454V5 2454v6 2454v5 01-1/2" VTR J 4 O 4 8 8"XI8" X5/8" OVERHEAD CFI DE3PENSER WATER IBERGLA55 JUMP DUCT 100 amp Panel 0 120/240 v., I 0VN STUBBED INTO � ENUM GRILLS, LINED with I/2" GYPSUM. 2 (TYPICAL ALL UNITS) U-) g CSI 2 2EO- Lo c� N O 2 6. �. O do C4 4 3680 U a oo (6 U TILE 0 O °O cs�r -- 8 ^d MDQ ® I l O Z 00 °O 0° E�= m s n¢ .. --i - . 0_ OFFIC SPACE OFFI�II�SPACE TI 2 2 2 2.5 TON HVAC W/10 KW HEAT (n g STRIP 1000 CFM 5 IWC ESP - ❑ 240Y., 10 HVAC UNIT PROVIDED 2 8 WITH FRESH AIR INTAKE. CRT M,3A BARD WA301-AI® 0 6 6 23680 8 CFI Z 0 3680 �-1 til 2454V8 2454V5 21 36 0 S?/yTg 2454V6 CL W CLASSVS2E U3 16�_9,� 31 ._.g 19 -9 13 Vp4 Q Q 0 J� _u- ❑ 02 ❑0 z ~ Y00 N � M RT O(W Ur ANT ELECTRICAL PANEL. "A" 51ZING DISCRIPTION: CIRCUIT .0035KWefX120SFX125 3.15 12 RECEPTS 6 180 VA / 1000 2.20 EEMAX WATER HEATER Q 6.5K1 6.5 1 FAN 1 3 KW X 125 .315 HVAC 10.5 TOTAL 22.10 KW 30A 2P TOTAL. / 240 X 1000 94.58 A 0,8 INSTALL 100 AMP PANEL. 120 / 240V 10 ELECTRICAL. 5CHEDUL X 1 12-I/2" CIRCUIT NOMENCLATURE N LL. BREAKER (AMPS) UJIRE zE CU. NM. W/G. 1 4 3 HVAC 5TU0 HURRICANE MAX PER MFR SPECS. 5 41 EMAX r 30A 2P 10-2 0,8 RECEPTACLES 20A IP 12-2 2 LIGHTS LAY 20A 1P 12-2 ALL PORTABLE APPLIANCES, INCLUDING WIH. TO HAVE DISCONNECT IF NOT WITHIN VIEW OF ELECTRIC PANEL 1-1/2" VTR 1/2 �� UJC INSTANT WATER NEATERHEAp2)-2x4 5YER EEMAX SP -3512 OR EQUIP. P02 X 1 12-I/2" H1=ADER L.I_ N LL. 1-1/2" VTR W 1 I/2' STUD HURRICANE ANCHOR EQUAL x 5TU0 HURRICANE MAX (2)-2X4 SYP02 HEADER STRAP HEADER STRAP EQUAL TO EQUAL TO r HUGHES HLSTA 24 HUGHES HL5TA 24 (12600 UPLIFT) (12600 UPLIFT) ao " ANCHOR EQl1AL 0 LAY Ln TO HUGHES HC20 I 36-I/2" U) J 1/2 �� UJC INSTANT WATER NEATERHEAp2)-2x4 5YER EEMAX SP -3512 OR EQUIP. P02 X 1 12-I/2" H1=ADER N LL. � N 1 I/2' STUD HURRICANE ANCHOR EQUAL x 5TU0 HURRICANE MAX (2)-2X4 SYP02 r ao " ANCHOR EQl1AL 0 SIN L Y /2 TO HUGHES HC20 I TO HUGHES HC20 I J �../ (12500 UPLIFT) 3/4" INLET (1250 UPLIFT) SILL PLATE C CRIPPLE STUDS (2)-2X4 SYP02 SINK (2)-2X4 5YP02 3 n a 16 ° O.C. SUDS INSTALL AT FACTORY INSTALL AT FACTORY . (2)-2XLE (2)-2X4 5YP02 3 �� FA5TE La A 16" or-. 3" TO TERM. 3" TO ASTE TERM. SUPPLY LINE IS BASED ON AN ASSUMED A S 4 L 'S YIpI��p SIT 11/2" SLIP JOIi�T CONNECTIONS. AVAILABLE PRESSURE OF 46 TO 60 PSI AT MAIN - TRAPS UJITH INLET. ALL STUB -UPS I/2" TYPICAL DOOR FRAMIW3 TYPICAL WINDOW FRAMING DWV 5U PPl. TYPICAL FRAMING PLUMBING RISER SCALE: 3/8" =1'-0" SCALE: 1/2" = V-0"" DATE: 04/28/2009 r-- DRAWN: R.C.S. JOB #: STOCK SHEET NO. Al COPYRIGHT 2007 -MODULAR PLANS DESIGN, CO. RIDGE BEAM CONSTRUCTION 4 LAYERS 3/4" X 24" PLYWOOD, RATED SHEATHING, EXP. - 1, STRUCT - 1, 5 - PLY / 5 LAYER, 48/24 EACH HALF CONTINUOUS ENTIRE LENGTH OF BUILDING NOTES: 1. PLYWOOD FACE GRAINMUST BE PARALLEL TO THE RIDGE BEAM SPAN. 2. ALL PLYWOOD BUTT JOINTS MUST BE STAGGERED 24" MINIMUM. 3. ALL RIDGE BEAM PLYWOOD LAMINATIONS MUST BE THE SAME DEPTH, THICKNESS, AND GRADE OF PLYWOOD. NO LUMBER OR PLYWOOD FLANGES ARE PERMITTED. 4. PLYWOOD MUST BE MANUFACTURED IN ACCORDANCE W/ PSI - 95. 5. PLYWOOD LAMINATIONS IN EACH HALF OF THE UNITS MUST BE GLUE NAILED TO ADJACENT LAYERS IN ACCORDANCE W/ POS SUPPLEMENT #5, W/ AN ADHESIVE COMPLYING W/ ASTM D2559, OR CA25-4. 6. PLYWOOD MUST NOT BE TREATED W/ A FIRE RETARDANT PROCESS, 7. MOISTURE CONTENT MUST BE LESS THAN 16%. 8. BEAMS MUST EXTEND CONTINUOUS OVER ENTIRE LENGTH OF ALL COLUMN SUPPORTS. 9. INSTALL (2 X 4) X 20" SPF # 3 RIDGE BEAM BEARING STIFFENER OVER SUPPORT COLUMNS. WHEN SPECIFIED ON FLOOR PLAN; FASTEN THE FACE OF THE STIFFENER TO THE RIDGE BEAM W/ 100% GLUE COVERAGE AND (6)15 GA. X 2 - 1/2" STAPLES. APPROVED TRUSS DESIGN TRUSS MFG. ALPINE ENGINEERED PRODUCTS TRUSS DWG. NO. 25389 FLORIDA'S DADE/BROWERED COUNTY REQUIREMENT INSTALL CONTINUOUS 3" WIDE PLWOOD BEARING STRIP OVER TOP PLATE AT ALL BEARING WALLS (TYPICAL) (THE SAME THICKNESS AS CEILING FINISH) NOTE: TRUSSES WITCH DO NOT FALL DIRECTLY OVER WALL STUDS SHALL BE STRAPPED TO TOP PLATE w/ (1) 26 GA. X 1 1/2" STRAP AND FASTENED w/ (8) 15 GA. X 1 1/2" STAPLER WITH MIN. I" PENETRATION PER STRAP END. STRAP WALL STUDS EITHER SIDE OF TRUSS TO DOUBLE TOP PLATE AND FABRENED w/ (8) 15 GA. X 1 1/2" STAPLES WITH MIN. P PENETRATION. ROOF COVERING OVER 1/4" DENS -DECK SEE HVAC PLAN FOR NOTE: TRUSSES WHICH DO NOT FALL DIRECTLY OVER WALL STUDS OVER 5/8" APA IRATED PLYWOOD SHEATHING RETURN AIR DUCT SHALL BE TO TOP PLATE AND THE TOP PLATE SHOULD BE STRAPPED MIN. EXP -I, 32/16. SEE ROOF SHEATHING SPECIFICATIONS AND t0 THE NEAREST ADJACENT STUD WITH EQUIVALENT FASTENING. DETAIL THIS SHEET. MECHANICAL NOTES F EC FILING DUCT P CATION LISTED TRUSSES A 24" O.C. 2 X 4 SPF *2 BOTTOM PLATE 15'-8" MAX. MODULE WIDTH LISTED TRUSSES m 16" O.C. MAX. LISTED ROOF TRUSS DESIGN LOADS: 11'-8" MAX. MODULE WIDTH 3/8" APA RATED SHEATHING EXPA, EXP EXT LISTED ROOF TRUSS DESIGN LOADS: - LIVE LOAD 20 PSS TOP CHORD a a 4'-0" LIVE LOAD 20 PFS TOP CHORDmlljlllllllDEAD LOAD 4 PSS TOP CHORD ENDWALLS) INSTALL DOUBLE STRAPPING DEAD LOAD 6 PSF TOP CHORD SEE APPROVED PACKAGE FOR CEILING DEAD LOAD 6 PSF BOTTOM CHORD -2, STAPLES DEAD LOAD 4 PSP BOTTOM CHORD -TO WALL FASTING RQUIREMENTS. TYP. WINDOW SILL FROM TOP FLANGE OF OUTRIGGER ' EXTERIOR WALL STRUCTURAL BRACING ; INTO FLOOR AND / OR RIM JOIST BRACING MATERAIL: 1/6" STRUCTURAL RED THERMO FASTENED SIDEWALLS: z OUTRIGGER ANC> CROOSMEMBER SPACING Im In RIM MEMBER 2X4 SPF "3 MIN. BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF A 48" O.C. MAX. - 130 MPH 30 GA. X 1 1/2" STEEL STRAP FROM 4' MINIMUM WDITH SHEET EXTENDING - PLY �� �: OR GALV. BOX NAILS 3 O.C. EDGES AND 12 O.C. FIELD TRUSS TO WALL STUD 16" O.C. WITH c CONTINUOUSLY FROM TOP t0 BOTTOM PLATE -I-16 C 6 GA. X I" STAPLES PER STRAP END WITH ALL SHEATHING EDGES EXTENING 3/4" DOUBLE STRAPPING AT EACH STUD FORMINIMUM OVER NA EXTERIOR WALL PINISNt 019 ALUM. R 2" NOMINAL LUMBER OF OF THE FIRST 4' IN FROM EACH CORNER SAME SIZE AND GRADE AS EXTERIOR WALL FRAMING. R - 11 KRAFTBACK WALL BRACING SHALL BE LOCATED AS CLOSE TO EACH R19 KRAFTBACK INSULATION ON EDGES AND 6" OC IN THE FIELD CORNER OF BUILDING AS POSSIBLE, WINDOW HEADER, SEE SPAN CHART -/BRACING MATERAIL: Lo m s POR SPECS. 5/8" APA RATED SHEATHING EXR I, EXP -2, EXT O N o QQc OR 5/6" APA RATED SIDING EXT. FASTENED W/ GLUE AND 10d COMON ♦ ♦ o TYP. WINDOW, SEE SHEET 02 FOR OR GALV. BOX NAILS 6" O.C. EDGES AND 6" O.C. FIELD WITH 10090 PER V a p °O EXTERIOR WALL STRUCTURAL BRACING p °O a SPECS. GLUE COVERAGE. � 19 `4 SIDEWALLS: .. c� co> BRACING INSTALLATION: ENDWALLS: 00 -< 2 X 4 SPF 02 WALL STUDS 16" O.C. STRUCTURAL SHEATHING SHALL CONSIST OFA BRACING INSTALLATION: ¢ a 1"� ❑ 4' MINIMUM WDIH SHEET EXTENDING. STRUCTURAL SNEA?HIND SHALL EXTEND CONTINUOUS CONTINUOUSLY FROM TOP TO BOTTOM PLATE FROM TOP OF TRUSS TOP CHORD TO 3/4" MINIMUM .... a WITH ALL SHEATHING EDGES EXTENING 3/4" BELOW TOP OF RIM JOIST WITH ALL SHEATHING EDGES O MINIMUM OVER 2" NOMINAL LUMBER OF OF THE SUPPORTED BY 2" NOMINAL LUMBER OF THE GRADE LL u SAME SIZE AND GRADE AS EXTERIOR WALL FRAMING. AS EXTERIOR WALL FRAMING. w 2 BRACING SHALL BE LOCATED AS CLOSE TO EACH ® c CORNER OF BUILDING -c AS POSSIBLE BRACING MATERIAL INSULATION.x L SMART PANEL SHEATING JOINTS SHALL BE CENTERED ALONG ui THE DOUBLE TOP PLATE. SHEATHING SHALL 13E FASTENED ft �- 2 X 4 SPF *2 BOTTOM PLATE 15'-8" MAX. MODULE WIDTH 30 GA. X 1 1/2" STEEL STRAP FROM WALL 11'-8" MAX. MODULE WIDTH 3/8" APA RATED SHEATHING EXPA, EXP EXT (� a a 4'-0" PER STRAP END. (TYPICAL SIDEWALLS t ' ENDWALLS) INSTALL DOUBLE STRAPPING 2x4 BLOCKING TYP. -2, STAPLES INSTALL (2) 3/8" X 3" LAG SCREWS TYP. WINDOW SILL FROM TOP FLANGE OF OUTRIGGER ' STAPLES INTO FLOOR AND / OR RIM JOIST BRACING MATERAIL: 1/6" STRUCTURAL RED THERMO FASTENED OR 3/8" APA RATED SIDING EXT. FASTENED W/ ed COMMON z OUTRIGGER ANC> CROOSMEMBER SPACING RAIL SIZE 48" O.C. MAX. - 130 MPH 2X10 - PLY �� �: OR GALV. BOX NAILS 3 O.C. EDGES AND 12 O.C. FIELD 1 C 6 WITH 16 GA. X P X 1 - 1/4" STAPLES 3" O.C. R - 11 KRAFTBACK WALL ON EDGES AND 6" OC IN THE FIELD NOTE: INSULATION.x L SMART PANEL SHEATING JOINTS SHALL BE CENTERED ALONG ui THE DOUBLE TOP PLATE. SHEATHING SHALL 13E FASTENED ft �- TYPICAL CROSS SECTION SCALE: 3/4" -1'-0" tH WELDS ONE SI rts AND uAs At r--12 GA. OUTRIGGER5 22-1/4" 12 GA. CROSSMEMBERS (t0 BE LOCATED OPPOSITE OUTRIGGERS AS SHOWN) FRAME DETAIL SCALE: NOT TO SCALE GENERAL CROSS - SECTION NOTES: I. UNLESS OTHERWISE SPECIFIED, ALL STEEL MUST COMPLY W/ ASTM A36, YIELD STRENGTH = 3(o KSI. 2. ALL LAG SCREWS MUST COMPLY WITH ANSI / ASME 518),1, Fyb ■ 60 KS.I. MIN 3. TRUSS BOTTOM CHORDS MUST BE BRACED IN ACCORDANCE WITH SPECIALTY ENGINEERS DESIGN DRAWINGS. ENDWALLS: TO THE TOP PLATE. A 6 O.C. USING bd COMMON NAILS. BRACING INSTALLATION: z u) STRUCTURAL SHEATHING SHALL EXTEND CONTINUOUS O ¢ FROM TOP OF TRUSS TOP CHORD TO 3/4" MINIMUM 7 BELOW TOP OF RIM JOIST WITH ALL SHEATHING EDGES p SUPPORTED BY 2" NOMINAL LUMBER OF THE GRADE -' U. A$ EXTERIOR WALL FRAMING. _ = o BRACING MATERIAL: ®o z g 3/8 CDX PLYWOOD EXP -1 24/0 FASTENED WITH -1/16 0 0 - Lu X 1 1/2" X 16 GA. STAPLES 3" O.G. EDGES 6" O.C. FIELD. to Y 1-3/8" C� 7 1/2" MAX 3.r 1-3/8" 1 OUTRIGGER SECTION CROSSMEMBER SECTION ry0 LL RAIL REQUIRED AT TOP AND FASTEN ROOF SHEATHING TO (2) 2x6 SYP. "2 W BOTTOM, EXTENDING CONTINUOUS ROOF SHEATHING TOP PLATE WITH BOUNDRY FASTENER SPACING. 4'-0" MINIMUM PAST END WALL SEE ROOF SHEATHING DETAIL. WITH NO END JOINTS ROOF SHEATHING EXTEND END WALL SHEATHING CONT. TO ROOF SHEATHING AND FASTEN t0 112'-1 O" BLOCKING TOP PLATE WITH THE SAME FASTENER U o - - - - - - - - SIZE AND SPACING REQUIRED FOR THE END WALL. (3)-15 GA x 1/16" x 2-1/2" STAPLES EACH END (� �- FASTEN EACH m RAIL t0 EACH (3) -0.148 DIA x 3" NAILS FROM RAIL t0 EACH ALo PPROVED TRUSS ` ' TRUSS (SEE CHART) STUD �' /1 X 2x3 SYP 03 FRAMING At 24" O.C. MAX N EXTERIOR FINISH INSTALL FIREBLOCKING AT EACH MATE LINE. MATERIALS NOT FIREBLOCKING SHALL BE AT LEAST ONE LAYER L1.. SHOWN OF 3/4" PLYWOOD EXTENDING FULL HEIGHT AND 110 -10 WIDTH of ovERHANG. J - - - (3)-15 GA x 1/16" x 2-1/2" STAPLES EACH END 2x6 FIRE STOP ACTUAL OVERHANG LENGTH 6" O SIDE WALL BLOCKING BETWEEN ALL STUDS AT o CEILING LINEL 2x6 SYP 01 STUDS A 16" OC RAIL AND RAIL FASTENING CHART 2 X 4 SPF *2 BOTTOM PLATE 15'-8" MAX. MODULE WIDTH 30 GA. X 1 1/2" STEEL STRAP FROM WALL 11'-8" MAX. MODULE WIDTH STUD TO FLOOR JOIST AT OPENING STUDS AND 16" O.G. WITH "1- 16 GA. X P STAPLES 4'-0" PER STRAP END. (TYPICAL SIDEWALLS t ' ENDWALLS) INSTALL DOUBLE STRAPPING 2x4 BLOCKING TYP. AT EACH END CORNER. STAPLES INSTALL (2) 3/8" X 3" LAG SCREWS \ / / FROM TOP FLANGE OF OUTRIGGER ' STAPLES INTO FLOOR AND / OR RIM JOIST RAIL SIZE ABOVE ( TYP. EACH OUTRIGGER) RAIL SIZE OUTRIGGER ANC> CROOSMEMBER SPACING RAIL SIZE 48" O.C. MAX. - 130 MPH 2X10 8 2X8 1 2X8 6 FULL LEW's OF ALL FLANG ALL OUTRI, PLYWOOD ROOF SHEATHING NAILING PATTERN 5/8" PLYWOOD SHEATHING SHALL BE BLOCKED SCALE: 3/8" = 1'-0" WITH 2x NOMINAL LUMBER OF THE SAME SPECIE AND GRADE AS TRUSS TOP CHORD FOR A DISTANCE OF 4'-0" FROM EACH END WALL WITH ROOF BOUNDARIES NAILED AT 4'-0" D.C. AND OTHER BLOCKED EDGES NAILED At 6" O.C. AND UNBLOCKED EDGES At 6" O.C- NAIL FIELD LOCATIONS AS FOLLOWS 4" O.C. IN AREAS WITHIN 4'-0" OF BUILDING CORNERS b" O.C. At ALL OTHER - LOCATIONS WITHIN 4'-0" OF EXTERIOR EDGES OF BUILDING 10" O.C. ELSEWHERE. ALL NAILS SHALL BE 10d COMMON NAILS. INTERIOR FINISH MATERIAL EXTERIOR FINISH MATERIAL CEILING: T -GRID CEILING INSTALLED PER MANUFACTURER'S SPECS. ROOF: 45 MIL BLACK RUBBER ROOF COVERING (EPDM) INSTALLED PER MANUFACTURE'S SPECIFICATIONS. WALL: 5/16 INCH HARDI-PANEL OVER APPROVED MOISTURE WALL- I/2" VINYL COVERED GYPSUMWALLBOARDt BARRIER AND BRACING MATERIAL FASTEN w/ 8d COMMON INSTALLED PER MANUFACTURER'S SPECS. NAILS a 4" O.C. (EDGE) AND 8" O.C. (FIELD). FLOOR: BLOCK TILE IN BATHROOM AND WET AREAS. NOTE: ALL ROOF COVERINGS SHALL MEET CLASS C OR BETTER REQ. CARPET IN ALL OTHER AREAS. ROOFING AND SIDING MATERIALS AND THERE FASTENINGS SHALL BE DESIGNED AND INSTALLED SO AS TO RESIST THE COMPONENT WIND LOAD SHOWN ON THE COVER SHEET. ALL ROOF COVERINGS SHALL MEET CLASS C OR BETTER REQUIREMENTS. WALL FINISH SHALL BE INSTALLED OVER APROVED MOISTURE PROTECTION AND BRACING MATERIAL. MOISTURE PROTECTION BEHIND WALL COVERING SHALL BE AS REQUIRED BY EXTERIOR WALL FINISH MANUFACTURER'S SPECIFICATIONS, BUT NOT LESS THAN ONE LAYER OF NO. 15 ASPHALT FELT, COMPLYING WITH ASTM 0226 FOR TYPE I FELT ATTACHED IN SUCH A MANNER A$ TO PROVIDE A CONTINUOUS - WATER - RESISTIVE BARRIER BEHIND THE EXTERIOR WALL FINISH. TYPICAL CROSS SECTION SCALE: 3/4" -1'-0" tH WELDS ONE SI rts AND uAs At r--12 GA. OUTRIGGER5 22-1/4" 12 GA. CROSSMEMBERS (t0 BE LOCATED OPPOSITE OUTRIGGERS AS SHOWN) FRAME DETAIL SCALE: NOT TO SCALE GENERAL CROSS - SECTION NOTES: I. UNLESS OTHERWISE SPECIFIED, ALL STEEL MUST COMPLY W/ ASTM A36, YIELD STRENGTH = 3(o KSI. 2. ALL LAG SCREWS MUST COMPLY WITH ANSI / ASME 518),1, Fyb ■ 60 KS.I. MIN 3. TRUSS BOTTOM CHORDS MUST BE BRACED IN ACCORDANCE WITH SPECIALTY ENGINEERS DESIGN DRAWINGS. ENDWALLS: TO THE TOP PLATE. A 6 O.C. USING bd COMMON NAILS. BRACING INSTALLATION: z u) STRUCTURAL SHEATHING SHALL EXTEND CONTINUOUS O ¢ FROM TOP OF TRUSS TOP CHORD TO 3/4" MINIMUM 7 BELOW TOP OF RIM JOIST WITH ALL SHEATHING EDGES p SUPPORTED BY 2" NOMINAL LUMBER OF THE GRADE -' U. A$ EXTERIOR WALL FRAMING. _ = o BRACING MATERIAL: ®o z g 3/8 CDX PLYWOOD EXP -1 24/0 FASTENED WITH -1/16 0 0 - Lu X 1 1/2" X 16 GA. STAPLES 3" O.G. EDGES 6" O.C. FIELD. to Y 1-3/8" C� 7 1/2" MAX 3.r 1-3/8" 1 OUTRIGGER SECTION CROSSMEMBER SECTION ry0 LL RAIL REQUIRED AT TOP AND FASTEN ROOF SHEATHING TO (2) 2x6 SYP. "2 W BOTTOM, EXTENDING CONTINUOUS ROOF SHEATHING TOP PLATE WITH BOUNDRY FASTENER SPACING. 4'-0" MINIMUM PAST END WALL SEE ROOF SHEATHING DETAIL. WITH NO END JOINTS ROOF SHEATHING EXTEND END WALL SHEATHING CONT. TO ROOF SHEATHING AND FASTEN t0 112'-1 O" BLOCKING TOP PLATE WITH THE SAME FASTENER U o - - - - - - - - SIZE AND SPACING REQUIRED FOR THE END WALL. (3)-15 GA x 1/16" x 2-1/2" STAPLES EACH END (� �- FASTEN EACH m RAIL t0 EACH (3) -0.148 DIA x 3" NAILS FROM RAIL t0 EACH ALo PPROVED TRUSS ` ' TRUSS (SEE CHART) STUD �' /1 X 2x3 SYP 03 FRAMING At 24" O.C. MAX N EXTERIOR FINISH INSTALL FIREBLOCKING AT EACH MATE LINE. MATERIALS NOT FIREBLOCKING SHALL BE AT LEAST ONE LAYER L1.. SHOWN OF 3/4" PLYWOOD EXTENDING FULL HEIGHT AND 110 -10 WIDTH of ovERHANG. J - - - (3)-15 GA x 1/16" x 2-1/2" STAPLES EACH END 2x6 FIRE STOP ACTUAL OVERHANG LENGTH 6" O SIDE WALL BLOCKING BETWEEN ALL STUDS AT o CEILING LINEL 2x6 SYP 01 STUDS A 16" OC RAIL AND RAIL FASTENING CHART WIND 15'-8" MAX. MODULE WIDTH 13'-8" MAX. MODULE WIDTH 11'-8" MAX. MODULE WIDTH SPEED (EXP. C) MININUM STAPLES MININUM STAPLES MININUM STAPLES RAIL SIZE PER RAIL RAIL SIZE PER RAIL RAIL SIZE PER RAIL 130 MPH 2X10 8 2X8 1 2X8 6 Nom: I. THIS DESIGN IS BASED ON ASCE 1 - 02 WITH A ROOF ANGLE OF LESS THAN 10". 2. ALL RAILS ARE SYP n LUMBER OR BETTER 3. ALL FASTENERS ARE 15 GA. X 1/16" X 2 - 1/2" STAPLES OR EQUAL. SECTION A -A ENDWALL DETAIL SCALE: 1- 1/2" = F-0" SCALE: V = P-0" FA5TEN IN511DE RIM JOIST TO FLOOR J015T REVISION DATE: DATE: 04128/2009 WITH 3- 1(oD NAILS PER FLOOR J015T, FA5TEN OUTSIDE RIM JOIST TO INSIDE RIM `'�, DRAWN: R.C.S. J015T WITH I(oD NAILS 5PACED 51, O.C. UNIT#: FLOOR JOIST 1 SHEET No. SCALE: V =1 I -,oil A3 Q COPYRIGHT 2007 -MODULAR PLANS DESIGN, CO. FRAME TIE -DOWN STRAP AND GROUND ANCHOR ON CENTER SPACING CHART. WIND SPEED WITHIN 6'-0" OF END WALLS ELSEWHERE 90 MPH 10' - 4" „ 12' - 0" 100 MPH 8' - 4" -, 12' - 0" 110 MPH 6'-10"0, 10'-4" 120 MPH 5' 8" 130 MPH 4' - 6" l' - 4" 140 MPH 3' - 9" V - 4"1 150 MPH 31 - 411 to 5' - 4" ALL POINTS ALONG I -BEAMS SHALL BE WITHIN 1/2 OF THESE DIMENSIONS OF A STRAP/ANCHOR LOCATION. so THE FIRST STRAP/ANCHOR LOCATION FROM EACH END SHALL NOT EXCEED 1/2 OF THIS DIMENSION. FOUNDATION DIMENSIONS A. MODULE WIDT 5. PIER TO MODULE EDGE C. STEEL BEAM SPACING 11' - S" 2211 EJ — 1/2 11 D. MAX. PIER SPACING MINIMUM SOIL BEARING CAPACITY 2000 P5F 3000 PSF FOUNDATION NOTES: NOTE: ALI, REQUIRED BUILDING AND/OR CONSTRUCTIONPERMITS MUST BE APPLIED FOR AND OBTAINED FROM THE LOCAL AUTHORITIES HAVING JURISDICTION PRIOR TO ANY WORKED BEING DONE ON THE ABOVE SHOWN FOUNDATION DESIGN. 1. THE ABOVE FOUNDATION DESIGN IS TO BE SUBMITTED TO THE LOCAL JURISDICTION HAVING AUTHORITY. THE APPROVAL OF THIS FOUNDATION IS 6-0" TYP. SUBJECT TO LOCAL JURISDICTION: r------------------ ---- 2. TIE -DOWN STRAPS TO BE I-1/4" X.035 GALVANIZED STEEL FEDERAL I F.T. F.t. F.T. T. F.T. F.T. F.T. F.T. F.T. F.T. SPECIFICATIONS QQS-781-H TYPE -I FINISH -B GRADE -1. TIE -DOWN STRAPS AND CONNECTING HARDWARE TO -- --- 1I- -- ----} I----- --I (----- -----} __ _--�- -�—_-----•---F- -I------ —I ,--F- 1 T- 17—mm --I F_ — F —1 F 8 —1 HAVE 4,725# L L- — J L _ J L _ Lr — MINIMUM ULTIMATE CAPACITY (3,150 # X 1.5). A 3. ALL TIE DOWN ANCHORS SHALL HAVE MINIMUM 6,500 LB. CAPACITY AND SHALL BE INSTALLED IN ACCORDANCE WITH THEIR FL LISTING APPROVAL. o ( A4 6 4. SEE ABOVE FOUNDATION LAYOUT FOR TIE -DOWN STRAP SPACING, Q Q� ,c 5. ALL PIERS SHALL BE 8" X 8" X16" MASONRY BLOCKS ON 16" X 16" X 4" (DEEP) a p ` a u CONCRETE PADS EXCEPT AS OTHERWISE NOTED ON FOUNDATION PLAN. M �' ¢ (0 0 a 6. MINIMUM SOIL BEARING CPACITY IS 2 000 PSF. TO BE VERIFIED BY BUILDING'S Z 4k °° °° °` F 7 F 7 r > OWNER. a __ _ � — L _ L _ L. _ L — L_ — 7. IT WILL BE THE BUILDING OWNER'S RESPONSIBILITY TO INSURE THAT ALL ®" o �- F.T. T. T. t. T. T. T. T. T. T. GRASS, LOOSE DEBRIS, ETC. ARE REMOVED FROM UNDER THE BUILDING U- u, uj — — — — _ — — — — — — — _ — — J (FOOTING) AND THAT THE GROUND IS LEVELED TO WTHIN 6" AND FIRMLY ❑ a v MAXIMUM WIND SPEED 130 MPH. PER ASCE-1-02 ALL TIE DOWN ANCHORS SHALL HAVE MINIMUM 47125 LB. CAPACITY AND ASHALL BE INSTALLED IN ACCORCANCE WITH THEIR APPROVAL. FOUNDATION PLAN SCALE: 1/4" = 1'-0.. P.T. 2x8 SHIMS . p I'-7" 4"x8"Ab" CAP BLOCK 19"x19"x7/8" A85 PAD 8"x8"Aiv" CAP BLOCK NOTE: MAXIMUM OF (2) LAYERS L OF 11100D MAY BE USED 19"xl9"x3/4" AB5 PAD NOTE: AT LEAST (1)4"x4"xlb" CAP MODEL *3083 (MINUTE MAN INC) BLOCK MUST BE USED AT ALL PIERS (OR APPROVED EQUAL) A PIER ��A�� EQUAL OR EXCCEAD Ea .55 5F. MIN SCALE: 3/4" = 1'-0" SIDE WALL FRAME TIE-DMI4 STRAP t0 BE 1113TALLED ABOVE I -BEAT^ PERIMETER RAI FRAME I -,SEAM FRAME OUTRIGG R BEYOND --- E CROSS 111`115ER BEYOND PIER TYPE A (TYP) EXISTING GRAME NOTE: CRIMP STRAP WITH a A LISTED STRAP CRIMP OR J -HOOK WRAPPED AROUND 17BEAM rt TYP. GROUND ANCHOR , tr 16 n 17, COMPACTFD. n 8. WOOD SHIMS MAY BE INSTALLED WHEN NECESSARY, BETWEEN THE I -BEAM a AND THE TOP OF THE PIER. SHIMS SHALL BE FREE OF KNOTS, CHECKS, SPLITS, z AND SIMILAR IMPERFECTIONS. SHIMS SHALL BE OF P.T. LUMBER OR CEDAR AND BEARING PRIOR TO ADDING THE SHIMS. 9. MASONRY PIERS MAY BE INSTALLED IN A DRY STACK SUBJECT TO LOCAL uj JURISDICTION. 10. OVERALL WIDTH DIMENSIONS IS NOMINAL AND IS BASED ON UNIT WIDTH X �/ ® w o NUMBER OF UNITS, ACTUAL OVERAL WIDTH MAY INCREASE DUE TO SITE w a CONDITIONS, MATERIAL TOLERANCES, FAILURE 2 TO REMOVE CLOSE-UP MATERIAL AND/OR OTHER FACTORS BEYOND THE coo CONTROL OF THE BUILDING MANUFACTURERS. 9 Z 11. FIELD CONDITIONS WITH DRY STACK PIERS GREATER THAN 34" SHALL ® Z _w REQUIRE FONDATIONS TO BE ENGINEERED BEYOND THIS APPROVAL. C,� �' N g c 12. WHERE REQUIRED BY LOCAL JURISDICTION ALL MASONRY PIERS MAY LAID IN TYPE "M" OR "S" MORTAR IN COMPLIANCE w/ASTM C887, OR SHALL HAVE SURFACE BONDING MORTAR IN COMPLIANCE w/ASTM C 946. ✓� PL SYMBOLS TF.T. FRAME TIE -DOWN FASTENED TO GROUND ANCHOR • HURRICANE STRAP SHEET NO. �.�-. SECTION TIE DOWN, SIDEWALL TYP. �.� SCALE: 3/4 F-0" A4 ( COPYRIGHT 2007 -MODULAR PLANS DESIGN, CO