Loading...
HomeMy WebLinkAbout585 Merrybrook Cir (fr sp rev) (2)4r• rev Revision Response to Comments ❑ JAN 2.8 2016 B" . Permit # 15-2802 RIC[ City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Submittal Date 01/28/16 Project Address: 535 Merry Brook circle (Lot 126) Contact: Mickey Ferguson Ph: 407-877-5582 Fax: 407-656-8026 Email. mferguson@waynefire.com Trades encompassed in revision: General description of revision: ❑ Building ❑ Plumbing ❑ Electrical ❑ Mechanical ,�j Life Safety Com'"'...... ."--+'1 ( Revised overhead drawings due to revised underground layout (Per Richard Blake) Fire Sprinkler BOTH UNDERGROUND & OVERHEAD ON SAME SET OF PLANS Department ❑ Utilities ROUTING INFORMATION Approvals ❑ Waste Water ❑ Planning ❑ Engineering Fire Prevent\c ❑ Building �� /Zf 2S 7i 0 N I.fl rl O N N N r-i ►i Garage F------------- 1 � P_' U—_.....—___---__ I ' I CL U BIRCH UNIT SPIGOT LOCATION DETAIL 1/4' = 1'-0' F EL. 01 _OD GROUND FLOOR Garage ------------------- ; 1 f \ ! 1 \� I O ` � I f O-------------------- I ICL I U REDWOOD UNIT SPIGOT LOCATION DETAIL 2' 1' 0 4' 8' SCALE 1/4' = 1' : GARAGE INTERIOR CONCRETE 5LA5 RE FORCED. IMPORTANT OWNER INFORMATION GRAPHICS ELEMENTS NOTE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, EDITION (EITHER STATE OR LOCAL) OF NEPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, DR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR. THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER, IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS _ CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPEC'F:CATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TU THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. 2V MIN, STEEL SLEEVE PIPE SOCK W CPVC 90° ELL F1. MBp I d& IIm 1/4' = 1'-0' Garage --------------------------------------ll rrr , I r - r ___-___7s ;_--__.___-----------------------�..�.... _ I C, I V WILLOW UNIT SPIGOT LOCATION DETAIL EL. +5 1_(�II 2ND FLOOi� EXTERIOR GRADE FEE SPRNCLER SPIGOT OETAL SCALE, 1/2' = 1' WATER SUPPLY INFORMATION DESIGN CRITERIA aD * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. W ALL PLASTIC PPE 3/4 THROUGH 2Y2" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED N ACCORDANCE WITH ASTM F442. # ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. W ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING "ONE STEP' 500 CEMENT. W ALL STEEL PPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. W ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI BE.3 AND ASTM A 153. 0 ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. * BRASS PPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. • WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNC PIPING. * UN OE NdD MANS AND LEAD -NS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. W ALL PIPING SHALL BE BURS A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PPE PER WAFS COMPANY STANDARDS. IN ALL PIPING UNDER ROADWAYS SHALL BE BURIED A IuPNMU1M OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. * ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING. 0 ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. W VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). * ALL PAINTING OF PPE AS REQUIRED IS BY OTHERS. # WAR=S TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS. 633. 0 SEE CIVIL. DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S PONT OF CONNECTION. * PER FLORIDA STATUTE 633.539. ALL UNDERGROUND FROM THE POINT OF SERVICE TO T-0' AFF SHALL BE INSTALLED BY ONE CLASS I, I OR V LICENSED CONTRACTOR. # ALL FERROUS PPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. * CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. SPRINKLERS SPACING MAXIMIINI MINIMUM CDIENTS NEPA 130 2010 TOWNH ONE LI OERGROLIND GENERAL NOTES SCALEI NONE I}. %ria.., Mas. I—«>ANTIrf--i SPRINKLERS r IlisAisT12ND13RD14NI SIN kizd K kEld MODEL TOTAL PER FLOOR AL THIS SHEET Oi WILKINS 2 3 SMITH COOPER 4 5 PROVALUE ANVIL 6 7 SOUTHERN VALVE IMPORT 8 9 WARD 10 Y4' GALV, THREADED PLUG (@ Y4' BRONZE 3 -WAY VALVE is 3W WATER PRESSURE GAUGE Y' X 3' GALV. NIPPLE 0___ J' X Y4' GALV. BUSHING 0 W.A,F,S, TO TIE INTO THE OCTAVE METER. 2'X2'X'O� GALV, REDUCING TEE 00675N ■ REV. 2.0 DATE SUBYI'f MS BY 09/08/15 QA REVIEW MPF V 12/01/15 REV,I QA REVIEW MPF NO. ACTIIaL WOM [R (ASWM CAU FOIE PMAPsnia MAL Mg / AKm SISI GM a PSIp,U MPF IM2ARD STATIC PWSSIIIE 67 PSI 18158 ON ok HYDRANT ELEV. 2' K OF SPRu KM AREA RESIDUAL PFESSIM 57 PSI DATE OF TEST 08/WI5 NNW B0I m FM IN GM IWO TTM TIDE F TEST 1000 AM BEM AREA SF, PITOT WADE 37 PSI NUMBER ff PORTS FLOWED 1 Psi mn emu TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, V_ GN RM a BASK Psi REn I TEST I Cpm RER'B a TEST EIEVATBN I HIMNESI SPRBM M HYIXm LOCATION OR �� TEST HYDRANT LOCATED ON WHITE CEDAR ROAD ME 96 DD?ESTIC Dl]wm DESIGN CRITERIA aD * DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13D, LOCAL PLUMBING CODE AND ALL APPLICABLE LOCAL AND STATE CODES. W ALL PLASTIC PPE 3/4 THROUGH 2Y2" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED N ACCORDANCE WITH ASTM F442. # ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. W ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING "ONE STEP' 500 CEMENT. W ALL STEEL PPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A795 OR ASTM A-53. W ALL THREADED FITTINGS SHALL BE GALVANIZED MALLEABLE IRON CLASS 150 OR CLASS 300 AND SHALL BE MANUFACTURED IN ACCORDANCE WITH ANSI BE.3 AND ASTM A 153. 0 ALL GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. * BRASS PPE AND FITTINGS WILL BE UTILIZED ONLY AS REQUIRED BY LOCAL WATER PURVEYOR. • WAFS TO PROVIDE CPVC COMPATIBLE AGAVE 14 GAUGE TRACING WIRE ON ALL UNC PIPING. * UN OE NdD MANS AND LEAD -NS SHALL BE FLUSHED PER FLOW RATES IN NFPA 24 PRIOR TO CONNECTING TO OVERHEAD PIPING. W ALL PIPING SHALL BE BURS A MINIMUM OF 30 INCHES BELOW GRADE TO THE TOP OF THE PPE PER WAFS COMPANY STANDARDS. IN ALL PIPING UNDER ROADWAYS SHALL BE BURIED A IuPNMU1M OF 36 INCHES BELOW GRADE TO THE TOP OF THE PIPE. * ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING. 0 ALL PIPING SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. W VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). * ALL PAINTING OF PPE AS REQUIRED IS BY OTHERS. # WAR=S TO PROVIDE ALL NECESSARY SIGNAGE INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS. 633. 0 SEE CIVIL. DRAWINGS FOR DETAILS OF PIPING PRIOR TO WAYNE AUTOMATIC'S PONT OF CONNECTION. * PER FLORIDA STATUTE 633.539. ALL UNDERGROUND FROM THE POINT OF SERVICE TO T-0' AFF SHALL BE INSTALLED BY ONE CLASS I, I OR V LICENSED CONTRACTOR. # ALL FERROUS PPE AND FITTINGS SHALL BE EXTERNALLY WRAPPED AND COATED WITH A BITUMINOUS COATING. * CLEARANCES AROUND FIRE PROTECTION APPLIANCES SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITY. SPRINKLERS SPACING MAXIMIINI MINIMUM CDIENTS NEPA 130 2010 TOWNH ONE LI OERGROLIND GENERAL NOTES SCALEI NONE I}. %ria.., Mas. I—«>ANTIrf--i SPRINKLERS r IlisAisT12ND13RD14NI SIN kizd K kEld MODEL TOTAL PER FLOOR AL THIS SHEET Oi WILKINS 2 3 SMITH COOPER 4 5 PROVALUE ANVIL 6 7 SOUTHERN VALVE IMPORT 8 9 WARD 10 Y4' GALV, THREADED PLUG (@ Y4' BRONZE 3 -WAY VALVE is 3W WATER PRESSURE GAUGE Y' X 3' GALV. NIPPLE 0___ J' X Y4' GALV. BUSHING 0 W.A,F,S, TO TIE INTO THE OCTAVE METER. 2'X2'X'O� GALV, REDUCING TEE 00675N ■ REV. 2.0 DATE SUBYI'f MS BY 09/08/15 QA REVIEW MPF V 12/01/15 REV,I QA REVIEW MPF NO. DATE REVISIONS BY MAL Mg 11/30/15 REVISED FIRE LDC UNDERGROUND, MPF ANA CITY OF SANFORD CONWACT l 18158 ON ok CENTER OF TILE JOB? ❑ YES 0 NO CENTER ON FIXTURES JOB?[:] YES JZ NO SHM #CWfl F p ■ UTMN TYPEI V -13V - I>CI�IPANCYI R-3 14GA. COPPER LOCATING WIRE (AGAVE WIRE) FINISHED GRADE Al C 1�1�1�1 NOTES: 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE (14 GAUGE COPPER AGAVE WIRE) CAPABLE OF DETECTION BY A CABLE LOCATOR AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. 2. LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX AND BE CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A MANNER AS TO NOT INTERFERE WITH VALVE OPERATION. 3. USE FGG/BM COMPATIBLE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE TOP OF THE PIPE. TYPICAL LOCAT7F�� NO SCALE R» si++� � 00185N MANUFACTURER LIST I3 FPPI NIBCO UNITED BRASS ii TYCO NIBCO 14 ARGCO SPEARS FPPI i2 TYCO VIKING ASHCROFT ANVIL VICTAULIC ,s (IN ACCORDANCE W/ SHURJOINT ANSI/ASTM A-53) 2' DOUBLE DETECTOR CHECK BACKFLOW PREVENTER W/ BUTTERBALL VALVES, (SEE MANUF, SPEC SHEET FOR FRICTION LOSS INFORMATION) 0 smi 2' X 3' GALV, NIPPLE 2' X 4' GALV. t0 THRD. X GRV. 2' X 3'-8' is GALV. SCH-40 2' GALV, O 90' ELL —� 2' X 3' O GALV, NIPPLE 2' CPVC tt FEMALE ADAPTER — 2' X 1#' CPVC BUSHING — 2' GALV. t2 GRV. COUPLING e BFl 2' GALV, O THREADED PLUG 2' GALV, O TEE TO 1t' CPVC SYSTEM 2' WLIWS 950XLMABF DOUBLE DETECTOR CHECK BACKFLOW PREVENT63 W/ BIJ I I ERBALL VALVES - GALVANIZED uc SCALEI 1/2' = Y AUtOMatiC Fire Sprinklers, Inc. MAIN OFFICE - ORLANDO. FLORIDA 222 CAPITOL tOUT OC )M FLORIDA 34761 PHONE (407) 658-3030 FAX- (407) 666-80e8 JACKSONVILLIEL FL TAMPA, FL IRM>1nPAN0 BEACH. FL 8328 Offn &)TON AVE WEST 3EE6 CHERRY PALM OR FVE 3121 NW ISTH TERRACE JACKSONVLLE Fl 3ffi7 58-2746 TAMPA. FL 336 POMPANO BEACH,R_ 33084-1408 PHONE (804) 288-3030 PHONE (813) 630--0303 PHONE (054) 97-3030 FAX (904) 299-0724 FAX WO 830-032 FAX (054) 99-8424 FT. RM1fM FL CONCORD. NC STATE LICB43ES 4803 LAH®0 AVE 4370 MOTORSPORT OFM NC SPFRAGM;k 29745 FT. MYERS. FL 33806-4924 CONCORD. NC 25027-6077 NC ALARM: EOM SP LV PHONE (E3B) 433-3030 PHONE 004) 782-3032 SC SPR04G.E)i 1118 FAX (239) 433-3E83 FAX (704) 796-8838 SC ALAW 3385 00581L ?' LOTS 126-131 EBROOKIETOWNH OMES WHITE CEDAR ROAD TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 'a unz FIRE PROTECTION SITE NOTES & DETAILS PLAN DRAW( P MICKEY FERGUSON MAL Mg 110 DAM SEPTEMBER 8, 2015 ANA CITY OF SANFORD CONWACT l 18158 ON ok CENTER OF TILE JOB? ❑ YES 0 NO CENTER ON FIXTURES JOB?[:] YES JZ NO SHM #CWfl F p ■ UTMN TYPEI V -13V - I>CI�IPANCYI R-3 NOTE t THESE CUFF TIMES ARE FOR NEW COPTS I RJUM F GLIJNG INTO E K STNI3 PPNG► SLEHl AS N THE CASE OF CUT -NS, Cly TLE SH MJLD W A 16MUN CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 PSI (MAXIMUM) TEST PRESSURE (SEE NOTE D ONE STEP SOLVENT CEMENT TEST PRESSURE (SEE NOTE D E AMBIENT TEMPERATURE DURING CURE PERIOD 60'F TO 120'17 40'F TO 59'F 0'F TO 39'F FINCHES 45 MIN, 1,5 HR. 24 HR. 1 45 MIN, 1.5 HR,24 HR, LINCHES 1.5 HR, 16 HR, 120 HR. 48 HR, 1,5 HR. 16 HR. 120 HR, 32 HR. 6 HR. 36 HR. SEE NOTE 2 HR. 8 HR, 72 HR, SEE NOTE 2 3' 8 HR, 72 HR, SEE NOTE 2 NOTE t THESE CUFF TIMES ARE FOR NEW COPTS I RJUM F GLIJNG INTO E K STNI3 PPNG► SLEHl AS N THE CASE OF CUT -NS, Cly TLE SH MJLD W A 16MUN CURE TIMES WITH 225 PSI (MAXIMUM) ONE STEP SOLVENT CEMENT TEST PRESSURE (SEE NOTE D 'R' @ GREATER THAN 100 PSI E AMBIENT TEMPERATURE DURING CURE PERIOD 60'F TO 120'F 40'F TO 59'F 0'F TO 39'F (L) IN FEET 1 HR, 4 HR, 48 HR, LINCHES 1.5 HR, 4 HR, 48 HR, 70,5' 3 HR, 32 HR. 10 DAYS 6,3' 3 HR. 32 HR, 10 DAYS 100.1' 8 HR. 48 HR. SEE NOTE 2 28,5' 24 HR. 96 HR. SEE NOTE 2 0.7' 24 HR, 96 HR. SEE NOTE 2 NOTE t THESE CUFF TIMES ARE FOR NEW COPTS I RJUM F GLIJNG INTO E K STNI3 PPNG► SLEHl AS N THE CASE OF CUT -NS, Cly TLE SH MJLD W A 16MUN ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX HANGER BE INDICATED WITH A (zt) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PPE 3/4" THROUGH P -Y2 SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED N ACCORDANCE WITH ASTM F-442 ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED N ACCORDANCE WITH ASTM F438, ASTM F438 OR ASTM F1970. ALL CPVC PPE AND FITTNGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. UNHEATED OR CPUC PPE SHALL BE ALLOWED TO BE USED N ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.22.3). ONE RESTRAINT POINT - SEE TABLE 1 BELOW WITH TWO RESTRAINT POINTS - ❑ ALL r TO 2' THREADED BLACK STEEL PPE SHALL BE UL 11QTED/FM APPROVED AND MANUFACTURED-� CEILING SEE TABLE 2 BELOW N ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PPE BRANDS ARE WHEATLAND R MAX 'MEGATHFEAD'. ALLIED UYNATHREAD', BULL MOOSE TUBE 'EDOYTHREAD' AND WELDED TUBE -BERKELEY // 19'-8* L FEET i L MAX STEADY -THREAD'. Al PPE SHALL BE CPVC COMPATIBLE HEATED HEATED --- ---� ❑ ALL r TO 2' THREADED GALVANIZED PPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED UNIT UNIT MANUFACTURED N ACCORDANCE WITH ASTM A-795 OR ASTM A-53. 2 \ \ D E] ALL r TO 2' TW EARED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND L __ ___ MANUFACTURED N ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE d = 0.329 D d INCHES WHEATLAND. ALL®, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PPE SHALL BE CPVC COMPATIBLE SPRINKLER 90' ELL DROP SUPPORT SPACING WITH ❑ ALL #Y; TO 4• GROOVED BLACK STEEL PPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED J ONE RESTRAINT POINT -SEE TABLE 1 BELOW MAXIMUM SUPPORT SPACING N ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE'EDDYFLOIM, WHEATLAND SEE TABLE 3 BELOW 'MEGA -FLOW', ALLIED 'OYNA-FLOW AND WELDED TUBE -BERKELEY 'STEADY -FLOW ALL PPE SHALL BE PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (73'F) (ONE END RESTRAINED) 'R' @ GREATER THAN 100 PSI ZE PIPE SIZE INCHES 0'-6' LENGTH OF RUN (L) IN FEET LENGTH OF RUN (L) IN FEET 2' 5' 7' 10' 12' 15' 17' 20' 2' 5' 7' 10' 12' 15' 17' 20' Y' 1,3' 7,8' 15,4' 31,3' 45,1' 70,5' 90,6' 125.4' 1' 1,0' 6,3' 12.3' 25,0' 36.0' 56,3' 72.3' 100.1' 14' 0,8' 5,0' 9.7' 19,8' 28,5' 44.6' 57,3' 79,3' IV 0.7' 4,3' 8,5' 17.3' 24,9' 39.0' 50.1' 69,3' 2' 0,6' 3,5' 6,8' 13.9' 20.0' 31,2' 40.0' 55,4' 2V 0,5' 2,9' 5.6' 11,4' 16,5' 25.8' 33.1' 45,8' 3' 0.4' 2.4' 4,6' 1 9,4' 1 13.5' 21,2' 27,2' 37,6' ALL MATERIAL APPLICABLE TO THIS PROJECT WILL R MAX ANY DISTANCE S AX HANGER BE INDICATED WITH A (zt) (1/2 'S' MAX) OR CLAMP (TYP,) ALL PLASTIC PPE 3/4" THROUGH P -Y2 SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED N ACCORDANCE WITH ASTM F-442 ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED N ACCORDANCE WITH ASTM F438, ASTM F438 OR ASTM F1970. ALL CPVC PPE AND FITTNGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. UNHEATED OR CPUC PPE SHALL BE ALLOWED TO BE USED N ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR INSULATION ATTIC LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION (BY OTHERS) SPRINKLER TEE DROP SUPPORT SPACING WITH SPRINKLER DROP SUPPORT SPACING 5.22.3). ONE RESTRAINT POINT - SEE TABLE 1 BELOW WITH TWO RESTRAINT POINTS - ❑ ALL r TO 2' THREADED BLACK STEEL PPE SHALL BE UL 11QTED/FM APPROVED AND MANUFACTURED-� CEILING SEE TABLE 2 BELOW N ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PPE BRANDS ARE WHEATLAND R MAX 'MEGATHFEAD'. ALLIED UYNATHREAD', BULL MOOSE TUBE 'EDOYTHREAD' AND WELDED TUBE -BERKELEY // 19'-8* L FEET i L MAX STEADY -THREAD'. Al PPE SHALL BE CPVC COMPATIBLE HEATED HEATED --- ---� ❑ ALL r TO 2' THREADED GALVANIZED PPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED UNIT UNIT MANUFACTURED N ACCORDANCE WITH ASTM A-795 OR ASTM A-53. 2 \ \ D E] ALL r TO 2' TW EARED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND L __ ___ MANUFACTURED N ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE d = 0.329 D d INCHES WHEATLAND. ALL®, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PPE SHALL BE CPVC COMPATIBLE SPRINKLER 90' ELL DROP SUPPORT SPACING WITH ❑ ALL #Y; TO 4• GROOVED BLACK STEEL PPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED J ONE RESTRAINT POINT -SEE TABLE 1 BELOW MAXIMUM SUPPORT SPACING N ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE'EDDYFLOIM, WHEATLAND SEE TABLE 3 BELOW 'MEGA -FLOW', ALLIED 'OYNA-FLOW AND WELDED TUBE -BERKELEY 'STEADY -FLOW ALL PPE SHALL BE ria- si ruw III ■ NOTE 21 FOR THESE SIZES, THE SOLVENT CEMENT CAN BE APPLIED AT TEMPERATURES L FEET BELOW 32'F, HOWEVER, THE SPRINKLER SYSTEM TEMPERATURE MUST BE RAISED TO A TEMPERATURE OF 32'F OR ABOVE AND ALLOWED TO CURE PER THE ABOVE RECOMMENDATIONS PRIOR TO PRESSURE TESTING. 2 \ D / d = 0,0823 L \ \ d INCHES D TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT PERMISSIBLE BENDING DEFLECTIONS SDR 13,5 (73'F) (BOTH ENDS RESTRAINED) 'R' @ LESS THAN 100 PSI 'R' @ GREATER THAN 100 PSI ZE 0'-9' 0'-6' LENGTH OF RUN (L) IN FEET 1'-0' 0'-9' 2' 5' 7' 10' 12' 15' 17' 20' 1'-0' 0.3' 2,0' 3.8' 7,8' 11.3' 17,6' 22.6' 31,3'0,3' FINCHES PSI RM (I HYD 1,6' 3,1' 6.3' 9,0' 14.1' 18,1' 25,0'0.2' 1,2' 2,4' 5.0' 7,1'11.2' 14.3' 19,8'0.2' 1.1' 2,1' 4,3' 6.2' 9,7' 12,5' 17.3' 0,1' 0.9' 1,7' 3,5' 5.0' 7,8' 10,0' 13.9' 0,1' 0.7' 1,4' 2.9' 4,1' 6.4' 8.3' 11.4' 0.1' 0,6' 1.2' 1 2,4 3,4' 1 53' 6.8' 1 ria- si ruw III ■ NOTE 21 FOR THESE SIZES, THE SOLVENT CEMENT CAN BE APPLIED AT TEMPERATURES L FEET BELOW 32'F, HOWEVER, THE SPRINKLER SYSTEM TEMPERATURE MUST BE RAISED TO A TEMPERATURE OF 32'F OR ABOVE AND ALLOWED TO CURE PER THE ABOVE RECOMMENDATIONS PRIOR TO PRESSURE TESTING. 2 \ D / d = 0,0823 L \ \ d INCHES D TABLE 1 - SPRINKLER SUPPORT SPACING DISTANCE WITH ONE RESTRAINT POINT NOM. PIPE SIZE 'R' @ LESS THAN 100 PSI 'R' @ GREATER THAN 100 PSI Y4 INCH 0'-9' 0'-6' 1 INCH 1'-0' 0'-9' 1X INCH 1'-4' 1'-0' 13i INCH 2'-0' 1'-0' 4¢ INCH 2'-0' 7'-0' TABLE 2 - SPRINKLER SUPPORT SPACING DISTANCE WITH TWO RESTRAINT POINTS NOM, PIPE SIZE 'S' @ LESS THAN 100 PSI 'S' @ GREATER THAN 100 PSI N INCH 4'-0' 3'-0' 1 INCH 5'-0' 4'-0' 134 INCH 6'-0' 5'-0' 132 INCH 7'-0' 7'-0' )13¢ INCH 7'-0' 7'-0' TABLE 3 -MAXIMUM SUPPORT SPACING NOM. PIPE SIZE Y4 INCH 1 INCH 134 INCH 13¢ INCH 2 INCH 23¢ INCH 3 INCH SUPPSPACIORTNG L' 5'-6' 6'-0' 6'-6' 7'-0' 8'-0' 9'-0' 10'-0' CPVC COMPATIBLE 2ND FLOOR ❑ ALL IY4 TO 4- GROOVED BLACK STEEL PPE SHALL BE SCHEDULE 10. UL LIST®/FM APPROVED AND MANUFACTURED N ACCORDANCE WITH ASTM A-795. ACCEPTABLE MANUFACTURERS ARE BULL MOOSE, WHEATLAND, ALLIED AND WELDED TUBE -BERKELEY. ALL WE SHALL BE CPVC COMPATIBLE N\// CEILING ❑ ALL GROOVED STEEL PPE 6- AND LARGER SHALL BE UL LISTED/FM APPROVED SCHEDULE 10 AND 9'-4" MANUFACTURED N ACCORDANCE WITH ASTM A-135. ❑ ALL GROOVED STEEL PPE 13'4' AND LARGER SHALL BE SCHEDULE 10 HOT DIPPED GALVANIZED AND HEATED HEATED MANUFACTURED N ACCORDANCE WITH ASTM A-795. UNIT UNIT ❑ ALL STEEL PPE SHALL HAVE A CORROSION RESISTANCE RATIO (CRR) OF NOT LESS THAN LO PER WAFS STANDARDS. ❑ ALL BLACK THREADED FITTINGS SHALL BE DUCTILE IRON CLASS 150 OR CLASS 300 ANSI 816.3, CAST IRON CLASS 125 OR CLASS 250 ANSI B1BA OR MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI 816.3. 816.3 WITH GALVANIZED COATING N ACCORDANCE WITH ASTM A-153. .w ~ w ti.a 1ST FLOOR ❑ ALL WELDED OUTLETS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED N ACCORDANCE WITH ANSI 816.11. ❑ GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED N ACCORDANCE WITH ASTM A-538 FOR DUCTILE FION OR ASTM A-47 FOR MALLEABLE IRON. ❑ ALL GALVANIZED GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED N ACCORDANCE WITH ASTM A-538 FOR DUCTILE KION OR ASTM A-47 FOR MALLEABLE KION i GALVANIZED COATING SHALL BE N ACCORDANCE WITH ASTM A-153. ❑ ALL GROOVED STEEL PIPE SHALL BE ROLL GROOVED PER PPE MANUFACTURER REQUIREMENTS. ` TYPICAL CPVC CLM TLES CPVC BEN OM DEFLECTIONS TYPICAL CPVC HANGER/BRACE SPACING PIPE AND RTTNGS GENERAL NOTES I INN SCALES NONE&\"v4wSCALE: NONE SCAOL q=LE= NONE SCALES NONE Tia" RESIOENnAL CFS SECTION - 2 FLOOR Automatic Fire SRa*+dw�a, Ina Automatic Fire Sp*ddws. Tac. Automatic Fire SPrrrdwc tic. Irrbsnl0o Fh I1Ptldwr, be. SCALEi NONE 00415N 00416N 00356N 00859N Automatic Fire SwWdara, tic 00683N CEILING #12 X 134' HARDENED CPVC SPRINKLER CEILING TYPICAL CEILING STRAP MAY BE USED HEX HEAD LINE (' TO 2') ALTERNATE USAGE OF DIFFUSER IN THIS POSITION AS SELF -THREADING A FIG, 24 PIPE HANGER 11-01 A RESTRAINER ONLY SCREW TOLCO FIG. #22C � TYP. SOFFIT (CONSISTING OF (2} VIEW A TYP, TYP (OBSTRUCTION) B �17TYPICAL PENDENT TOLCO FIG, 22 PIPE SPRINKLER CPVC SPRINKLER STRAPS) WOOD FRAMING TYPICAL 7, B TYP 'MTUMMT LINE (Y' TO 2') MEMBER rf r PENDENT A TYPICAL Ippp�' SPRINKLER OBSTRUCTION It r q,ASSffUTO rr rr rr rrrr ri'r r'rrr VIEW A r ALTERNATE USAGE OF D A SEE DETAIL VIEW FIG. 24 PIPE HANGER DETALVEW a WALL v � � A 00® " � ® 000 c9 A 2 (D - 8 IN,) + B (A > CD - 0.214) + B} TOLCO FIG. 22 WOOD FRAMING D S 30 IN. (0,814) O's �'` PIPE STRAP #10 X V OR TOLCO FIG. (SIZED TO PIPE) MEMBER #12 X VIIIHARDENED PIPE HANGER 4 CPVC SPRINKLER HEX HEAD LINE (Y4' TO 2') WOOD FRAMING SELF -THREADING SCREW HEAD SELFHTHREADING ARDENED EX MEMBER (X2) SCREW (X2) DISTANCE FROM SPRINKLER TO SIDE OF OBSTRUCTION (A) MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION UN,) (B) LESS THAN 1 FT. 6 IN, 0 1 FT, 6 IN TO LESS THAN 3 FT, 1 3 FT. TO LESS THAN 4 FT. 3 4 FT, TO LESS THAN 4 FT, 6 IN, 5 4 FT, 6 IN, TO LESS THAN 6 FT. 7 6 FT, TO LESS THAN 6 FT. 6 IN. 9 6 FT. 6 IN, TO LESS THAN 7 FT. U 7 FT, AND GREATER 14 NTA 13R 81 13D RESEEMML PENDENT HANGER E04F HANGER *04J PFPA 13R S 130 FESIOENTIAL PENDENT TYPICAL ENTIAL CELNG MOUNTED HOT AFI SPRNCLER CLEARANCE W/ SOFRT FOR eY4 TO 2" CPVC PPE HANGER SM FOR TO 2" CPVC PPEFIG. 24 HANGER FOR �4 TO 2" CPVC PIPE SPF (L.EA W/ OBS I RLIC I ION OFFIJsER SPFANKLER M CLEARANCES SCALEi NONE SCALE, NONE , SCALE NONE SCALE, NONE , SCALE NONE AutomaticF"° °''' 00531N A�a..uo Fry siairiira 00251N Fs. mid... 00250N Frt. s s i m ba 00282N Automatic F�'a . kw. 00527N Automslic Pro sp� Inc. SCALES 0702N IMPORTANT OWNER INFORMATION GRAPHICS ELEMENTS NOTE WATER SUPPLY INFORMATION THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE EDITION (EITHER STATE OR LOCAL) OF NEPA 25 AS THE APPLICABLE STANDARD FORBACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR WOWP GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES OR IN SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLEREXTRAPQATEfl WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER ACTIN BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED (AS REQ'D IN AH,D SEE, GPM Ii PSI FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS STATIC PRESSURE 67 PSI HYDRANT ELEV, 2' CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE VFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. SYSTEM / IO1 HAZARD OAU 11 IF VRINERS IN RESDDIIAL PESSIX 57 PSI BY DATE ff TEST 08/31/15 DESD31 AREA )mD7ADI DDatry RON DI GPM 1020 GN i TDE W TEST MAN DEsml AREA PIIOT WADDIG 37 PSI MOTHER OF PORTS FLOWED 1 pu En a Dy TEST PROVIDEID BY VAYNE AUTOMATIC FIRE SPRINKLERS, INC. CSN wn ! Dv PSI RM (I HYD WNFM8HYD HYDRANT LOCATIDN OR NUMBER TEST HYDRANT LOCATED ON VWTE CEDAR ROAD ELEVATOR E HOE 02KER HIM nE/aursloE D NUM DEMAND DESIGN CRITERIA SPRINKLERS SPACING SYMBOL I MAXIMUM I MOMUM I COMMENTS r -QUANTITY --1 SPRINKLERS ,Tj3MjMj4THj SN ISIZEI KMF MODEL TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET DATE SUBIQITES BY 09/08/15 QA REVIEW MPF 12/01/15 REV1 QA REVIEW MPF i SEPTEMBER 8, 2015 A" CITY OF SANFORD „ 18158 i swu + FPD. 1 N0. DATE REMIONS BY A 11/30/15 REVISED FOR NEW UNDERGROt1ND LAYOUT, I MPF Automatic Fire Sprinklers, Inc. MAIN OFFICE - ORLANDO. FLORIDA 222 CAPI COURT OCOM FLOWA 34761 PHONE (407) 656-3030 FAX: (407) 656-6026 JACKDONvu.E R TAWa a. PCWANO SEAt31. R MW OISTR RITION AVE WEST 3886 CHERRY PALM DRIVE 3121 NW 6TH T6iiACE JACI(SONVI LE FL 38258-2746 TAAPA. FL 3386-8337 POMPANO BEACH FL 33064-1100 PHONE (604) 838-3030 PHONE 08) 6.30-0303 PHONE 0M) SD -3030 FAX (904) B89-0724 FAX (88) 830-0312 FAX (854) SD -8484 FT. MYEM R. r M r MF9% INC STATE 1 4883 LAREDD AVE 4370 MOIORSPORI DRIVE NC SPF*413l 89746 FT. MYl3iS. Fl 33601 CONCORD. NC 89027-0977 NC ALAFAk 28882 SP LV P! (230) 433-3030 PHONE 004) 762-303E! SC SPR*gB} MS FAX (838) 433-32133 FAX 004) 795-8838 SC ALAM: 3386 LOTS 126-131 � THORNWBROOKHITE o ROo pHOMES SANFORD. FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHM TUM FIRE SPRINKLER DETAILS BRAWN stn MICKEY FERGUSON TOTAL A/A 110 DM SEPTEMBER 8, 2015 A" CITY OF SANFORD „ 18158 CENTER OF TILE JI'iB? [:] YES ONO I CENTER IN FIXTURES JOB? [:] YES &ZM swu + FPD. 1 CONSTRUCTION TYKi V -B OCCUPANCY, R-3 ►. 71 In M Ln r -I O fV N r -i 2' 1' 0 4' 8' SCALE 1/4' = V IST FLOOR 2ND FLOOR BIRCH UNIT FIRE PROTECTION PLAN- (1,832 SCI. FT.) IMPORTANT OWNER INFORMATION( GRAPHICS ET EMENTS NOTE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTIOH DRAWINGS AND SHP DRAWINGS MAY INCLUDE 0 EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR BACKGROUND DRAWINGS GRAPHICS BORROWED FROM THE ARCHITECTURAL CIVIL, STRUCTURAL, OR MEP DRAWWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 4,1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AlD/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS _ CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IES SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION B-2 ACTA FaW EXTR ATTEED (AS REDO BY AH,D FOIE RAP NFPA 13D SIZE, GPM 8 PSI ��©■r����'dl STATIC PRESSURE 67 PSI 1261127: HIYMANT ELEV. 2' RESIDUA. 57 PSI JACK80NVA.LE FL MSS -2745 DATE OF TEST OB/3.15 FLOW IN GPM 1020 GPM PSI RE n I U 28.1 TIDE OF TEST IM AM PIIDT READN 37 PSI NUMBER OF PORTS FLOWED 1 TEST PROVIDED BY I WAYNE AUTOMATIC FIRE SPRINKLERS, INC, HYDRANT LOCATION( OR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD NIMBER SYSTm / # B-1 MU B-2 29 R ,,AZAR# mm NFPA 13D NFPA 13D Redwood ��©■r����'dl # W w0awfm2 K= AM 2 1261127: POIMPAND BEAM FL WI111IM wam ,05 .05 1 JACK80NVA.LE FL MSS -2745 EM AM SA 2 SPRKS 2 SPRKS PHONE (904) 288-3030 PHONE (813) 630-03M PSI RE n I U 28.1 44,3 FAX (80) 830-0312 FAX: MV W-9424 GN REo'n I TIB 26,3 40,6 STATE 1ICF3V8ESe 4803 LA1i®0 AVE PSI REI'# I WD 38.1 57.9 FT. MYERS,FL 33805-4924 CONCOM NC 28027-8977 WN REM) 111TH 31.3 45.6 PHONE (704) 782-303e SIC SPFMLE i MS MATO 11 Wr19'-8' � SPRlIaER 19'-8' SC ALAFIA 33M N/A N/A )N>IESTIC 5 GPM 5 GPM SPRINKLERS SPACING SYMBOL MAXON MINIMUM I MN ENTS 16'x16' a BETWEON 8'4 MAX SPACING OFF WALL U.N.O. DEFLE® U.N.O. SPRH(LERS 1104CBELOW CEILING TOR TO BE INSTALLED 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF BUILDING (WIRED BY OTHERS) lk' X 1I' X If' CPVC REDUCING TEE -----, x 14' x I' CPVC REDUCING TEE W/ V x V CPVC SPIG ADAPTER GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE lk'xl%'xl' CPVC REDUCING TEE— W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) li' CPVC CHECK VALVE 1V COUP & 1VX1 CPVC BUSHING OVEMEAD PERMIT T( START AT T-0' A.F.F. TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION WOOD f- llf' SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR U U DYNAFLOW SLEEVE---- FROM LEEVEFROM SUPPLY 1 1/2' BY OTHERS CPVC Fire Sp'k*Wm kw- TYPICAL J SPRINKLER 36' MINIMUM NO SPARE SPRINKLERS REQUIRED PER NFPA 13D V CPVC BALL VALVE I' CPVC 90' OUT WALL TO ISA' SPIGOT ADAPTER & SAWN HEAD PIPE ROTATED FOR CLARITY TYPICAL LIGHT ' SI FIXTURE *IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS, NFPA 13R rs 130 _SPRNCLEFI CLEARANCE W/ LIGHT FD(TLF E SCALER NONE Fire Sp•hm 00504N SPRINKLERS R 29 R i i Willow Redwood ��©■r����'dl Redwood l� 1261127: POIMPAND BEAM FL �; III' rv71.1 vM, � II 130' 30 NW ISH TERRACE JACK80NVA.LE FL MSS -2745 TAMPA. FL 33810-8337 POMPANO BEAM FL 33084-1408 PHONE (904) 288-3030 PHONE (813) 630-03M PHONE (964) 917-3030 FAX: (904) 288-0724 FAX (80) 830-0312 FAX: MV W-9424 FT. MYERB. FL CONCORD, NC STATE 1ICF3V8ESe 4803 LA1i®0 AVE 4370 MOTORSPORT ORIVE NC SPRNQ.M EMS FT. MYERS,FL 33805-4924 CONCOM NC 28027-8977 NC ALAMA EGM SP LV PHONE (239) 433-3030 PHONE (704) 782-303e SIC SPFMLE i MS FAX (239) 433-3E83 FAX (704) 796-8838 SC ALAFIA 33M 00■■ TOTAL PER FLOOR 1130 TOTAL PER UNIT ,I _TOTAL THIS SHEET DATE SUBYII'1'9S 09/08/15 QA REVIEW 12/01/15 REV,1 QA REVIEW SCALEi NONE • DESIGN AND INSTALLATION TO BE N ACCORDANCE WITH 2010 EDITION OF NFPA 130. • DESIGN AND INSTALLATION TO BE N ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PPE AND FITTINGS USED ON THIS PROJECT TO BE N ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PPE AND FITTINGS G N31AL NOTES (WAFS DETAL NOOSM). • ALL HANGERS SHALL BE OES04ED AND INSTALLED N ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED OULDNG ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK N ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HLTI FS ONE OR STI LCI. • UNDERGROUND MANS AND LEAD—INS SHALL BE RUSHED AND SIGNED TEST CERTIFICATES PROVE BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM B FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PIPING SHALL BE N 33MTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS RE12LMREO TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES F PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 803.4 (A. • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS N HOMES NOT EQLIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS N ACCORDANCE WITH NFPA 72, NATIONAL FRE ALARM CODE • CONMECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM. F PROVIDED, IS BY OTHERS. • ALL PANTING OF PPE AS REQUIRED B BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BONG CEMENTED N PLACE • ALL SPRINKLERS N DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 130. • RE -ER TO SPACING NOTES ON PLANS FOR MAXIM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED N ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE FRE=T, THE LEAST DIMBNISION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LMTEO—COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONISTRUCTON. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VEdTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONGEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL—FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LONG AS THEE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 100 CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CELNG ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FISH OF THE UNPROTECTED CEILING POCKET IS NONCOK48USTIBLE OR LIMITEO—COMBUSTIBLE MATERIAL 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13D INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 833. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM. SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIFE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. BY MPF MPF N0. I DATE I RECIONS I BY 11 A 11/30/15 1 REVISED FOR NEW UNDERGROUND LAYOUT, I MPF .uunu i ein (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R N* 130 SER CLEARANCE W/ CELM FAN SCALER NONE Pro may bw• 00505N NFPA M 2010 GENERAL NOTES SCALE, NONE 00678N W R 29 R i i Willow Redwood 222 CAPITOL COURT OCOEE• FLOWA 34761 Redwood l� 1261127: POIMPAND BEAM FL MES OISTRB n1ON AVE VMT 130' 30 NW ISH TERRACE LOTS 126-131 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD SANFORD. FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 s m nn.D BIRCH UNIT FIRE SPRINKLER LAYOUT NAWN BY, MICKEY FERGUSON TOTAL A/9 110 DMFa SEPTEMBER 8, 2015 AH► CITY OF SANFORD j amw # 118158 011 1 CENTER OF TILE JW []YES ONO I (I=NTER ON FIXTURES JOVE] YES JZ NO ,NREM # CONISTRMTIDN TYPE, V -B FPB, 1 °CCUPAKYR-3 Ar %AAA i i Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO. FLORIDA 222 CAPITOL COURT OCOEE• FLOWA 34761 PHONE (407) 656-3030 FAX- (407) 856-4301126 l� TAMPA. FL POIMPAND BEAM FL MES OISTRB n1ON AVE VMT 3228 CHERRY PALM DRIVE 30 NW ISH TERRACE JACK80NVA.LE FL MSS -2745 TAMPA. FL 33810-8337 POMPANO BEAM FL 33084-1408 PHONE (904) 288-3030 PHONE (813) 630-03M PHONE (964) 917-3030 FAX: (904) 288-0724 FAX (80) 830-0312 FAX: MV W-9424 FT. MYERB. FL CONCORD, NC STATE 1ICF3V8ESe 4803 LA1i®0 AVE 4370 MOTORSPORT ORIVE NC SPRNQ.M EMS FT. MYERS,FL 33805-4924 CONCOM NC 28027-8977 NC ALAMA EGM SP LV PHONE (239) 433-3030 PHONE (704) 782-303e SIC SPFMLE i MS FAX (239) 433-3E83 FAX (704) 796-8838 SC ALAFIA 33M LOTS 126-131 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD SANFORD. FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 s m nn.D BIRCH UNIT FIRE SPRINKLER LAYOUT NAWN BY, MICKEY FERGUSON TOTAL A/9 110 DMFa SEPTEMBER 8, 2015 AH► CITY OF SANFORD j amw # 118158 011 1 CENTER OF TILE JW []YES ONO I (I=NTER ON FIXTURES JOVE] YES JZ NO ,NREM # CONISTRMTIDN TYPE, V -B FPB, 1 °CCUPAKYR-3 V1 N Ln N u1 O C N r1 Fr F AFEA SR -1 UNIT R FAMLY ROOM T 0E8fE1 REFI NFPA 13M IT10N. SBCTEN 8.12 Rl 20' X 20' SPACING 20,0 GPM e 16,7 PSI R2 20' X 20' SPACING MY. p20GPM a 16,7 PSI ... 00853N 2' 1' 0 4' 8' I I I I SCALE 1/4' = F Storage I I No A/S I I Lj Y"tui-4to _4' Qlg/ Ir o`/ P I tr,yy \\ 14.7 Sq`,rt 9'-4' Clg, Garage No A/S 9'-4' Mg. Lanai No A/S r� j R1T • O,Lp'��O j L.f_1 : DO C} Family Room /?9'-4' Clg, r t Caf e 9'-4' CIgI s � Q � ^ O c I _1d 8'-0' Lintel Coats No A/S I DIEI 9'-4' Mg. PowderE,I I 1416 Sq FtI I N�S 9' laI 0-10 '-4'r Cl( Porch No A/S 1ST FLOOR 2ND FLOOR REDWOOD UNIT FIRE PROTECTION PLAN- 'IMPORTANT OWNER INFORMATION GRAPHICS ELEMENTS NOTE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FORBACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION STRUCTURAL, OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 4.1, THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE 1020 GPM SPRINKLER DRAWINGS OR DETAILS TIDE OF TEST CPVC COMPATIBILITY NOTICE PITOT WAN CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE NUMBER OF PORTS FLOWED THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE ® IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION. 8' BEIM SPIOR RS RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH TAMPA, FL 33810-8337 PH1M (818) 830-0303 CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE- SOME WIRES, FLUX, .I PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD FAX (813) 830-0312 SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN ! CENTER OF TILE JOB? [:] YES 0 ND I CENTER ON FIXTURES .OBI YES CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH CONCORD. INC 4370 MDTORSPO iT DRIVE CONCORD. NC 2B0E7-8877 PHONE (/04) 78E-3032 THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW,SYSTEMCOMPATIBLE.COM SHEET = FPR, 1 COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. it (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS FAX. (239) 433-3M PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE SC ALARM: 3386 NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED. ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. (1,943 SD. FT.) WATER SUPPLY INFORMATION FRONDED BY I WAYNE AUTOMATIC FIRE SPRINKLERS, INC. HYDRANT LOCATION( OR TEST HYDRANT LOCATED DII WHITE CEDAR ROAD N DIJIGN CRITERIA ACTUAL I mW OR (AS FM MAH.D IN HUMP SIZE, GPM e PSI Willow STATIC PRESSURE 67 PSI SPRINKLERS WI1RANT ELEV. 2' RESIDUAL PMO V PSI MAX" DATE OF TEST 08/31/15 FLOW IN GPM 1020 GPM 20 9 0 TIDE OF TEST 1040 AM PITOT WAN 137 PSI NUMBER OF PORTS FLOWED i FRONDED BY I WAYNE AUTOMATIC FIRE SPRINKLERS, INC. HYDRANT LOCATION( OR TEST HYDRANT LOCATED DII WHITE CEDAR ROAD N DIJIGN CRITERIA SPRINKLERS SPACING r--QuANTIrY--1 Willow WHITE CEDAR ROAD SPRINKLERS DATE MIMES BY SYMBOL MAX" MBVIMIM COMMENTS YND ® IST 7 1 20 9 0 3RD 4TH R3516 1' 4.9 155• RELIABLE KMEL F1 RES PES. VdM W RECESSED ESCS 83516 $' 4.9 175' S IM VIDTE W RECESSED DISCS 09/08/15 12/01/15 QA REVIEW REV,1 QA REVIEW r s I mnu__ ® 16'x16' U.N.O. 8' BEIM SPIOR RS MWAMM TAMPA, FL 33810-8337 PH1M (818) 830-0303 POMPANO MACH FL 33084-1408 PHONE: OM) 817-3030 CW ACT 4 18158 r 1®b'_M FAX (813) 830-0312 FAX (964) 817-84E4 ! CENTER OF TILE JOB? [:] YES 0 ND I CENTER ON FIXTURES .OBI YES FT. RIIIYEM FL 4883 LAREDO AVE FT. MYERS, FL 33906-49E4 PHONE: (E39) 433-3030 CONCORD. INC 4370 MDTORSPO iT DRIVE CONCORD. NC 2B0E7-8877 PHONE (/04) 78E-3032 STATE LCENSE& NC SPRNaEi! E9746 NC ALARIA E82EE SP LV SC 93RHMM IIB SHEET = FPR, 1 II\�li I `III ,®■�__ it OCCUPANCY, FAX. (239) 433-3M FAX (704) 795-8838 SC ALARM: 3386 To 6' 120VAC BELL W/WEATHERPROOF BACK BOX LOCATE ON OUTSIDE WALL OF BUILDING (WIRED BY OTHERS) 1111' X 111' X %' CPVC REDUCING TEE----, IV x 11(' x I' CPVC REDUCING TEE W/ V x 16' CPVC SPIG ADAPTER----- GALV, PLUG AND 300 PSI WATER GAUGE &3 -WAY VALVE 11I'xlk'xl' CPVC REDUCING TEE-- W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS) 11V CPVC CHECK VALVE --'-_�' 116' COUP & 3'4" CPVC BUSHING TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION WOOD FLOOR _TRUST 111' SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR NO SPARE SPRINKLERS REQUIRED PER NFPA 13D I' CPVC BALL VALVE B' IE' CPVC 90. OUT WALL TO VA' SPIGOT ADAPTER OVERFIEAD MFUT TO & SAWN HEAD START AT 1'-0' A.F.F. CL .- DYNAFLOW SLEEVE----- FROM LEEVEFROM SUPPLY 1 1/2' PIPE ROTATED FOR CLARITY BY OTHERS CPVC Plr• Sp *dd.rs, rr- TYPICAL SPRINKLER 36' MINIMUM TYPICAL EXPOSED CPVC FINE SPFWGQM RISER SCALE, NONE TYPICAL LIGHT ' Sf FIXTURE *IN ROOMS/COMPARTMENTS 400 CU, FT, OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS, NFPA 138 It 130 ER CLEARANCE W/ LIGHT FIXTURE lwft SCALE, NONE Fire Spm'' bw- 00504N • DESIGN AND INSTALLATION TO BE N ACCORDANCE WITH 2010 EDITION OF NEPA 130. • DESA AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PPE AND FITTINGS USED ON THIS PROJECT TO BE N ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PPE AND FITTINGS GENERAL NOTES (WAFS DETAIL II00593N). • ALL HANGERS SHALL BE DESIGNED AND INSTALLED N ACCORDANCE WITH NFPA 130 AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSB 43L.ES SHALL BE SEALED WITH FIRE CAULK N ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY S TO USE HLTI FS ONE OR STI LCI. • UNDERGROUND MAINS AND LEAD—NNS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. • WHEN SYSTEM IS FED USING PLUMBING NG SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. • ALL PPNG SHALL BE NSPMTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL COPES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES F PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. • VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS N HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS IN ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM, F PROVIDED, S BY OTHERS. • ALL PAINTING OF PPE AS REQUIRED IS BY OTHERS. • ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER S BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE • ALL SPRINKLERS N DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. • SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NDT REQUIRED BY NFPA 130. • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LINEN CLOSETS AND PANTRIES WITHIN THE DWELLING UMTS THAT OO NOT EXCEED 24 SQUARE FEET, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS ARE SURFACED WITH NONCOK48USTIBLE OR LIMTEO—COMB, STELE MATERIALS AS DEQ BY NFPA 22M STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHED PORCHES, CARPORTS AND SIMILAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING IMT VENTLAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL—FEED EQUIPMENT. a COVERED UNHEATED PROJECTIONS OF THE BLNLDNG AT ENTRANCES/EXITS AS LONG AS THERE S ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. o SPRNKL9RS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: 1. THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED 00 CU FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET S PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. 3. EACH UNPROTECTED CEILING POCKET S SEPARATED FROM ANY ADJACENT UNPROTECTED (SING POCKET BY A MINIMUM OF M FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET S NON(OMBUSTOLE OR LIMITED—COMBUSTIBLE MATERIAL 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13D INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. • DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. me go s sh .N ML VL1LF ' Ill\ (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R Er 130 it M CLEARANCE W/ CELNG FAN SCALE: NONE Fire Sp""".''', kw. 00505N 17 TOTAL PER UNIT 68 TOTAL THIS SHEET NFPA 130 2010 GENERAL NOTES SCALE, NONE 00678N W SPRINKLERS SPACING r--QuANTIrY--1 Willow WHITE CEDAR ROAD SPRINKLERS DATE MIMES BY SYMBOL MAX" MBVIMIM COMMENTS YND ® IST 7 1 20 9 0 3RD 4TH R3516 1' 4.9 155• RELIABLE KMEL F1 RES PES. VdM W RECESSED ESCS 83516 $' 4.9 175' S IM VIDTE W RECESSED DISCS 09/08/15 12/01/15 QA REVIEW REV,1 QA REVIEW MPF MPF ® 16'x16' U.N.O. 8' BEIM SPIOR RS t -p' MAX SPACING OFF WALL U.N.O. DEFLECTOR TO BE NSTAIIED 1'-4' BELOW CEILING TAMPA, FL 33810-8337 PH1M (818) 830-0303 POMPANO MACH FL 33084-1408 PHONE: OM) 817-3030 CW ACT 4 18158 FAX (004) 280-0724 FAX (813) 830-0312 FAX (964) 817-84E4 ! CENTER OF TILE JOB? [:] YES 0 ND I CENTER ON FIXTURES .OBI YES FT. RIIIYEM FL 4883 LAREDO AVE FT. MYERS, FL 33906-49E4 PHONE: (E39) 433-3030 CONCORD. INC 4370 MDTORSPO iT DRIVE CONCORD. NC 2B0E7-8877 PHONE (/04) 78E-3032 STATE LCENSE& NC SPRNaEi! E9746 NC ALARIA E82EE SP LV SC 93RHMM IIB SHEET = FPR, 1 CONSTRUCTION TYPE, V -B it OCCUPANCY, FAX. (239) 433-3M FAX (704) 795-8838 SC ALARM: 3386 R-3 i NO. DATE REVISIONS BY 11/30/15 REVISED FOR NEW UNIRGROUND LAYOUT, MPF 8 9 TOTAL PER FLOOR 17 TOTAL PER UNIT 68 TOTAL THIS SHEET NFPA 130 2010 GENERAL NOTES SCALE, NONE 00678N W 00 B THORNEBROOKE TOWNHOMES Willow WHITE CEDAR ROAD Birch SANFORD FL 32771 -1 126 TAYLOR MORRISON HOMES �129 iG1 MAIN OFFICE — ORLANDO. FLORIDA LOTS 126-131 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD WAWE SANFORD FL 32771 -1 TAYLOR MORRISON HOMES AutomatlC Fire sprinklers, Inc. 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 MAIN OFFICE — ORLANDO. FLORIDA SHEET TInUD REDWOOD UNIT FIRE SPRINKLER LAYOUT 2M CAPITOL COLT DCOE6. FLORIDA 34761 alw� ari MICKEY FERGUSON PRIONS (40" 656-303 X: 0 PA(407) 666 —6026 A/SI 110 R►TE;ATE >a SEPTEMBER 8, 2015 FL MES OISTRMUTM AVE WEST TAKWA. FL 3228 DOW PALM ORIVE POMPANO MACH, FIL 30 NW IM TERRACE CITY OF SANFORD JACKSONVILLE FL 3E256-2746 P1 (804) EM -3030 TAMPA, FL 33810-8337 PH1M (818) 830-0303 POMPANO MACH FL 33084-1408 PHONE: OM) 817-3030 CW ACT 4 18158 FAX (004) 280-0724 FAX (813) 830-0312 FAX (964) 817-84E4 ! CENTER OF TILE JOB? [:] YES 0 ND I CENTER ON FIXTURES .OBI YES FT. RIIIYEM FL 4883 LAREDO AVE FT. MYERS, FL 33906-49E4 PHONE: (E39) 433-3030 CONCORD. INC 4370 MDTORSPO iT DRIVE CONCORD. NC 2B0E7-8877 PHONE (/04) 78E-3032 STATE LCENSE& NC SPRNaEi! E9746 NC ALARIA E82EE SP LV SC 93RHMM IIB SHEET = FPR, 1 CONSTRUCTION TYPE, V -B OCCUPANCY, FAX. (239) 433-3M FAX (704) 795-8838 SC ALARM: 3386 R-3 F F 2' 1' 0 4' 8' 1 1 1 1 1 SCALE 1/4' = 1' 1ST FLOOR Laundry ~--Jj 8'-0' Clg' I Linn o �/S I C Bathroom #2" /i 0<1*S 8,_ ,C - Bath'41 #2 II 30,1 Sq I I No A/S Owner's Suite T-0' Clg, I czz I I 0 I 0 wner's `Bad 89,2 Sq Ft 8'-0' Clg, __l Lof t I 8'-0' C1g, VA ' 0 .•.O XP"'' A do v O �2p p (1 f I + ' Bedroom #2 II I I 8'-0' Clg, as I ' II0. (F F ...... ......... I I t 1 1 rLp � I Itfl 12- - WI_ 36 8 Sq Ft 8;-0' Mg, Bedroom #3 L-_____ W-0' Mg, 2ND FLOOR WILLOW UNIT FIRE PROTECTION PLAN (2,059 SQ. FT.) IMPORTANT OWNER INFORMATION GRAPHICS ELEMENTS NOTE D FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED BACKGROUND DRAWINGS GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, EDITION (EITHER STATE OR LOCAL) OF NEPA 25 AS THE APPLICABLE STANDARD FOR STRUCTURAL, OR MEP DRAWINGS.�HESE REFERENCE BACKGROUND ELEMENTS ARE FOR WI THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES SYSTEMS. PER SECTION 41 THE RESPONSIBILITY FOR PROPERLY MAINTAINING A NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS, THE FIRE SPRINKLER WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE BE UTILIZED IN FIRE THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY SPRINKLER DRAWINGS OR DETAILS # ff SP�ERS 2 IESI01 AREA 1 RESIDUAL PRESSIM CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE DATE OF TEST THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE mum nE mw ,05 IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION FLOW IN GPM RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH FAX 004) 796-8838 CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS (IE, SOME WIRES, FLUX, 1040 AN PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD 1 SPRKS SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN 37 PSI CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH 1 THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM 42.0 TEST PROVIDED BY COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, 20.0 ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT 51.6 ARE AND WILL REMAIN THE PROPERTYOF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. 25.0 (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED 31'-0' TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS TEST HYDRANT LOCATED ON WHITE CEDAR ROAD PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE N/A NFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS 5 GPM WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. WATER SUPPLY INFORMATION D 11/30/15 REVISED FOR NEW UNDERGROUND LAYOUT. ACTUAL OR EXTRAPOLATED (AS REn BY AH,D FIRE Pl1)PSYSTEM 3181 NW IM TERRACE / IIESM A W-1 W-2 Sal GPM a PSI PHONE: (904) ENHi`3030 ffi m NEPA 13D NEPA 13D STATIC PRESSURE 67 PSI FAX: (954) 9(7-9484 HYDRANT ELEV. 2' # ff SP�ERS 2 IESI01 AREA 1 RESIDUAL PRESSIM 57 PSI FT. MYM FL 31806-4984 DATE OF TEST 08/31/15 mum nE mw ,05 ,05 FLOW IN GPM 1020 GPM FAX 004) 796-8838 TDE OF TEST 1040 AN SF. 2 SPRKS 1 SPRKS PICOT READING 37 PSI NUMBER IF PORTS FLOWED 1 PS1 RE7n a BV 40.5 42.0 TEST PROVIDED BY WAYNE AUTOMATIC FIRE SPRINKLERS, INC, MPN Hi n a By 32.8 20.0 Pu REn e Ha 53.8 51.6 M;PMM RErn a MMYn 37.8 25.0 ELEVATOR a 19'-8' SfOlO.ER 31'-0' HYWM LOCATIDN OR NIMKR TEST HYDRANT LOCATED ON WHITE CEDAR ROAD DBEDE/a1TSM N/A N/A 5 GPM 5 GPM I QESRIN AFEA #W-2 2ND RIGOR IMT W OWNEI"S SUITE C0WAffrM 4T PER NFPA 1SD. 2010 EDITION!, SECTM 8.1E W3 20' X 20' SPACING 20.0 GPM @ 16.7 PSI 00853N ll a AFEA SIN -1 2ND REAM LNT W CMOAON AFEA COIIPAffrME 1T PE R NFPA M 2010 EOITKK SECTDM 61E W1 16' X 16' SPACING 13.0GPM 27.0PSI W2 18' X 18' SPACING 17.0 GPM a 12,0 PSI 00853N /S TO SPRINKLER SYSTEM SEE UNIT PLANS FOR CONTINUATION 6' 120VAC BELL W/WEATHERPROOF BACK v o� BOX LOCATE ON OUTSIDE WALL OF \WOOD FLOOR TRUSS BUILDING (WIRED BY OTHERS) --) 1:::.: 11 1$' SPLIT RING HANGER 3/8' A.T.R. & HILTI DROP-IN ANCHOR v > CL li' X 1i' X If' CPVC REDUCING TEE----. `� 1!1' x 111' x I' CPVC REDUCING TEE W/ REQUIRED PER NO SPARE SPRINKLERS 3D I' x V CPVC SPIG ADAPTER GALV, PLUG AND 300 PSI WATER GAUGE & 3 -WAY VALVE lVxlk'xl' CPVC REDUCING TEE W/POTTER GLUE IN FLOW SWITCH (WIRED BY OTHERS)' CPVC BALL VALVE 11(' CPVC CHECK VALVE IV COUP & IVXl CPVC BUSHING OVERHEAD PERMIT T( START AT 1'-W A.F.F. TYPICAL SPRINKLER SPRINKLERS SPACING r-QLV SYMBOL MAXD(UM MDNDIUM COMMENTS IST 2NR 1616' 8' BETWEEN a -O' MAX SPACING OFF WALL U.N.O. 6 12 CTOR® BE U.N.O. SPRNIQIRS 1'�4' BELOW CHUGSTALLED B I' CPVC 90' OUT WALL O'GOT ADAPTER &SAWNHEAD U �a CL DYNAFLOW SLEEVE FROM SUPPLY 1 1/2' BY OTHERS CPVC Fire Sp*d&m k= 36' MINIMUM PIPE ROTATED FOR CLARITY TYPICAL EXPOSED CPVC FLARE SER RISER SCALE, NONE TYPICAL LIGHT ' Sl FIXTURE 'IN ROOMS/COMPARTMENTS 400 CU, FT. OR LESS, SPRINKLERS MAY BE PLACED REGARDLESS OF LOCATION OF OBSTRUCTIONS, NFPA 13R OR 130 = EFI CLEARANCE W/ LIGHT RXTLI E SCALE, NONE Fes.., 00504N SPRINKLERS R3516 TOTAL PER FLOOR TOTAL PER UNIT TOTAL THIS SHEET * DESIGN AND INSTALLATION TO BE N ACCORDANCE WITH 20M EDITION OF NFPA 130. EH DESIGN AND INSTALLATION TO BE N ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. 0 ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE N ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PPE AND FITTINGS GENERAL NOTES (WAFS DETAIL 1). 0 ALL HANGERS SHALL BE DESIGNEO AND INSTALLED N ACCORDANCE WITH NFPA 130 AND THEIR LISTING. w ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HLTI FS ONE OR STI LCI. • UNOERGROIND MANS AND LEAD -NS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SPRINKLER SYSTEM. WHEN SYSTEM IS FED USING PLUMBING SERVICE, PIPING SHALL STILL BE FLUSHED PRIOR TO CONNECTING THE SPRINKLER SYSTEM. EH ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. +� ALL SYSTEMS SHALL BE TESTED AT 200 PSI FOR 2 HOURS PER WAFS STANDARDS. +� ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WRING OF DEVICES F PROVIDED (FLOW SWITCHES, TAMPER SWITCHES, ETC) IS BY OTHERS. +r VALVES SHALL NOT BE REQUIRED TO BE MONITORED PER FLORIDA BUILDING CODE 903.4 (1). • LOCAL WATERFLOW ALARMS SHALL BE PROVIDED ON ALL SPRINKLER SYSTEMS N HOMES NOT EQUIPPED WITH SMOKE ALARMS OR SMOKE DETECTORS N ACCORDANCE WITH NIDA 72, NATIONAL FIRE ALARM CODE. * CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM O3 MONITORING SYSTEM, F PROVIDED, LS BY OTHERS. 0 ALL PAINTING OF PPE AS REQUIRED IS BY OTHERS. ALL NNSUL.ATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER PIPING B BY OTHERS. Et HEATING OF ROOMS TO MAINTAIN TAT' OF 40 DEGREES OR GREATER IS BY OTHERS. • SPRINKLERS SHALL NOT BE INSTALLED PRIOR TO THE FITTINGS BEING CEMENTED N PLACE +� ALL SPRINKLERS N DWELLING UNITS SHALL BE UL LISTED OR FM APPROVED RESIDENTIAL SPRINKLERS. +� SPARE SPRINKLERS WILL NOT BE PROVIDED AS THEY ARE NOT REQUIRED BY NFPA 13D. +� REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. • SPRINKLERS SHALL BE INSTALLED N ALL AREAS EXCEPT AS FOLLOWS: o BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ FT. o CLOTHES CLOSETS, LIEN CLOSETS AND PANTRIES WITHIN THE DWELLING UNITS THAT DO NOT EXCEED 24 SQUARE RST, THE LEAST DIMENSION DOES NOT EXCEED 3 FEET, AND THE WALLS AND CEILINGS AM SURFACED WITH NONCOMBUSTIBLE OR TELE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. o ANY GARAGES, OPEN ATTACHE] PORCHES, CARPORTS AND SIMLAR STRUCTURES. o ATTICS, PENTHOUSE EQUIPMENT ROOMS. ELEVATOR MACHINE ROOMS, CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VE NTILAION EQUIPMENT, FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND 00 NOT CONTAIN FUEL -FIRED EQUIPMENT. o COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS AS LANG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING MT. o SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDTIONS: U THE TOTAL VOLUME OF UNPROTECTED CEILING POCKET DOES NOT EXCEED MO CU. FT. 2. THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILM ELEVATION. 3. EACH UNPROTECTED CEILING POCKET IS SEPARATED FROM ANY ADJACENT UNPROTECTED CEILING POCKET BY A MINIMUM OF 10 FT. HORIZONTAL DISTANCE. 4. THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. 5. SKYLIGHTS NOT EXCEEDING 32 SQ. FT. SHALL BE PERMITTED TO HAVE A PLASTIC COVER r WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NEPA 130 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS. AND INSPECTION TAGS AS REQUIRED BY FS SM. 0 DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS. AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIE PROTECTION SPECIALIST. wr. s�+a.w tie. M.uunu � nn (ANY MODEL IS ACCEPTABLE PROVIDED PLAN VIEW OF BLADES IS 50% OPEN) NFPA 13R rs 130 _ SPFWCLEA CLEARANCE W/ CEILING FAN SCALE, NONE Pro Sp*mws, W. 00505N DATE SUBI[IIRALS BY 09/x/15 QA REVIEW MPF 12/01/15 REV,1 QA REVIEW MPF NO. DATE REVISIONS BY 11/30/15 REVISED FOR NEW UNDERGROUND LAYOUT. MPF 11328 OBTRBUTION AVE WHET 3228 CHERRY PALM ORM 3181 NW IM TERRACE JACKSONVIlE FL 3ee86-2746 TAWA. FL 3368 -SW POMPANO BEACH FL 33064-1408 PHONE: (904) ENHi`3030 PH me am) 630-0303 PHONE: (954) 917-3030 FAX: (904) 898-0784 FAX: (613) 630-0318 FAX: (954) 9(7-9484 FT. MYEW FL CO NCOM NC STATE LCBrBES NFPA 130 EM GENERAL NOTES SCALE, NONE 00678N Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA 2E2 CAPITOL (SIT OCOEE, FMLOFIDA 34761 PIIONIIE (407) a56-3030 FAX: (40" 866-6066 FL TAMPA. FL POMPANO BEACK FL 11328 OBTRBUTION AVE WHET 3228 CHERRY PALM ORM 3181 NW IM TERRACE JACKSONVIlE FL 3ee86-2746 TAWA. FL 3368 -SW POMPANO BEACH FL 33064-1408 PHONE: (904) ENHi`3030 PH me am) 630-0303 PHONE: (954) 917-3030 FAX: (904) 898-0784 FAX: (613) 630-0318 FAX: (954) 9(7-9484 FT. MYEW FL CO NCOM NC STATE LCBrBES 4883 LAR®0 AVE 4370 MOTORSPORT ORNE NC SPF&AaZk E9745 FT. MYM FL 31806-4984 CONCOM NC 28027 877 NC AUU Mk 20W SP LV PHONE: (839) 433-3030 P1E1PE (704) 702-3= SC AMM 11B FAX: ON) 433-3883 FAX 004) 796-8838 SC ALARIA: 3385 LOTS 126-131 THORNEBROOKE TOWNHOMES WHITE CEDAR ROAD SANFCRD FL 32771 TAYLOR MORRISON HOMES 151 SOUTHHALL LANE, SUITE 200 MAITLAND, FL 32751 SHEET TITUD WILLOW UNIT FIRE SPRINKLER LAYOUT WAVN P MICKEY FERGUSON TUAL AM 110 DATER SEPTEMBER 8, 2015 AHJ CITY OF SANFORD cwrRw # 18158 CENTER OF TILE JOB? YESNO CENTER 01 FIXTURES JOB? YES jo NO SHEET # FPWA CONSTRUCTION TYPEi 13 OCCUPANCYV_ R-33