HomeMy WebLinkAbout615 W 25 Sti
,b
V .r > �s ----
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
ApplicationNo: j (a - Zo 28 ✓"��
Documented Construction Value: $ 4010 •(
Job Address: ioW Z15 T"-4 ST , S�lCc-(L-D, ;fj. 32111( Historic District: Yes ❑ No ❑
Parcel ID: , Residential E� Commercial ❑
Type of Work: New ❑ Addition ❑ Alteration 0 Repair ❑ Demo ❑ Change of Use ❑ Move ❑
Description of Work: Az2 �3� 6fi MMA2ZL yO ►LiTG &(I) PA-iQ6E Met- ( l
Plan Review Contact Person: T'i-IOMi�S C Title:
Phone: Fax: 401-45�4- Q3� Email: [ lrx Aa7/-7UL- rj, , Cj),M
Property Owner Information
Name "@A -T O Ln 40AS C, LL -C, Phone:
Street: 163 fft M E TTo ih/6 Resident of property?
City, State Zip: SA-1Wfb9-Q I 'F., 32711
Contractor Information
Name E121( 1✓L�TV-tC.rh, i_tv-19 Pilo Ile: 4o,7-'116 ' 810°1
Street: (PSO ( L. mg "StsC Std Sib 3 Fax: -,4b1--4SA -9b3�
City, State Zip: 4JIKI tM P/rYI-V-1, f t, 37_197 State License No.: EC1300SI(oS
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Architect/Engineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the (late of application and the code in effect as of that date: 5'11 Edition (2014) Florida Building Code
Revised: Jane 30, 2015 Pcruiit Applicutivn
SOU
PROPOSED 3D OF KITCHEN
N.T.S.
panoMpn
UAIHNUVM — ---- -- --
NON LOAD BEARING (CLOSET)
PROPOSED 3D OF KITCHEN /BATH
N,T.S.
ISED
LECTRIC
AND HOOD
FRONT)
40'-2"
PLUMBING SIZE NOTES:
ALL MAIN DRAIN LINES TO BE A MINIMUM OF 3" EXITING THE HOUSE. SHOULD THERE BE
MORE THAN 2 WATER CLOSETS THE MAIN LINE WILL EXIT 4". A STANDARD GUEST BATH
CONSISTING OF (1) WATER CLOSET, (1) LAV, (1) TUB/OR SHOWER WILL HAVE A MINIMUM
VENT SIZE OF 2" THRU ROOF, EACH HOUSE WILL HAVE (1) 311 MAIN VENT THRU ROOF.
A WASHER STANDING ALONE WILL HAVE A MINIMUM OF 1 1/2" VENT THRU ROOF, IF THE
WASHER IS STACKED WITH THE LAUNDRY TUB THE VENT THRU ROOF WILL BE 2". ALL
KITCHEN WILL BE AUTOVENT, 2" CLEAN OUTS WILL BE USED AT EXTERIOR WALL FOR
ACCESS. IN NO CASE WILL THERE EVER BE MORE THAN 3 MINOR AND (1) WATER CLOSET
VENTED ON LESS THAN A 2" VENT, A WASHER WILL NEVER DRAIN PAST ANOTHER TUB/OR
SHOWER USING THE SAME UPSTREAM VENT, AS WELL AS A WATER CLOSET WILL NEVER
DRAIN PAST A TUB/OR SHOWER USING SAME UPSTREAM VENT, BATH VENTS TO TERMINATE
THROUGH ROOF VENTS OR SOFFIT 3' MIN. FROM WINDOW AND DOOR OPENINGS.,
REVISION AND DATE
LEGEND
PROPOSED WOOD LOAD BEARING WALL (STUDS 16" 0. C.)
PROPOSED 6" WOOD FRAME WALL
PROPOSED 4" WOOD FRAME WALT_
PROPOSED 2" WOOD FRAME WALL
INFILL WITH STUDS OR CMU
PROPOSED 8" BLOCK WALL
b EXISTING ELECT. PLUG
PROP. ELECT, PLUG G.F.I.
PROP, ELECT, PLUG
NOTES:
NOTE: ALL CEILING DRYWALL SHALL BE "SAG RESISTANT
ELECTRICAL LEGEND
SYMBOL DESCRIPTION
�@
DUPLEX RECEPTACLE
X1/2 SX
6"-1 "
GFI
GFI PROTECTED RECEPTALCE
�GWP/Fi
SOUTH (REAR)
s
SINGLE RECEPTACLE
220 VOLT OUTLET
_6cLc.
-.2
SINGLE POLE SINGE THROW SWITCH
13
3—WAY SWITCH
11
4—WAY SWITCH
CEILING MOUNTED INCANDESCENT FIXTURE
H
SUSPENDED INCANDESCENT FIXTURE
O
RECESSED INCANDESCENT FIXTURE
8'-10 3/4" GI
RECESSED WATERTIGHT INCANDESCENT FIXTURE
�E
RECESSED EYEBALL INCANDESCENT FIXTURE
I-�
FLOURESCENT LIGHTING FIXTURE
WALL MOUNTED FIXTURE
FLOOD LIGHT
TO
TELEPHONE
6
DOOR CHIMES
'
PUSH BUTTON FOR DOOR CHIMES
TV
CABLE TELEVISION OUTLET
i. I
CEILING FAN LOCATION OR PREWIRE
sD
SMOKE DETECTOR
—OO
THERMOSTAT !
CD
CARBON MONOXIDE DETECTOR
EXISTING
j EXISTING
I�
10'-9" x 11'-5"
x 11'_5" _ jI
1!
,
EXISTING
12' -8"l' -2"
i
! —4,31080
li
jI fl
PROPOSED h
FIBERGLASS SHOWER V'
UNIT II
1' PROPOSED
\`
PROPOSED ;II
LIMITS OF CONSTRUCTION !I,
li
GARGBAGE
„
/4
DISP,
�- �
EXISTING II
II
WOOD FRAMED WALL f!
KITCHEN
NON LOAD BEARING (TYP.)
�D
1 ,l X 'I 3 10,l
8'-1 1
3'-11 3/4"
,
'
1
i
°D
EXISTING
l�
PROPOSED
o
II
LIGHT FIXTURES "�
n
1 1 -10 X 13-10 i!
o
--0 --=
7YP.
1j p
4
EXISTING L..................,
M
.�--
EXISTING
8' 4
1
! ��I
BATH
814"l Il v QI(}li ___
V 11
HALL 1
— - c
•____�____•: .....-._...-., u) co
i
4'_01t x Ei'-10° . n
I ,,
Iref I 4 y
— —
�
PROPOSED
WALL INFILL AREA
i y PROPOSED
N 'j
SINK SHALL STUDER
7 X 4 STUDS, TRIM OUT
y
r
II !VALVE
'I
(TYP.)
INSTEAD OF 3" VENT TO ROOF
PROPOSED WOOD FRAMED WALL
NOTE; ALL PROPOSED WALLS
NON LOAD BEARING (TYP,)
. AND INFILL AREA ARE NON LOAD BEARING
�
EXISTING
"
EXISTING
12'-6" x 12'-10"
''
16'-4" x 13'-5"
,
q
16'-3 1/4"
r !
{{
----
NORTH (FRONT)
40'-2"
PLUMBING SIZE NOTES:
ALL MAIN DRAIN LINES TO BE A MINIMUM OF 3" EXITING THE HOUSE. SHOULD THERE BE
MORE THAN 2 WATER CLOSETS THE MAIN LINE WILL EXIT 4". A STANDARD GUEST BATH
CONSISTING OF (1) WATER CLOSET, (1) LAV, (1) TUB/OR SHOWER WILL HAVE A MINIMUM
VENT SIZE OF 2" THRU ROOF, EACH HOUSE WILL HAVE (1) 311 MAIN VENT THRU ROOF.
A WASHER STANDING ALONE WILL HAVE A MINIMUM OF 1 1/2" VENT THRU ROOF, IF THE
WASHER IS STACKED WITH THE LAUNDRY TUB THE VENT THRU ROOF WILL BE 2". ALL
KITCHEN WILL BE AUTOVENT, 2" CLEAN OUTS WILL BE USED AT EXTERIOR WALL FOR
ACCESS. IN NO CASE WILL THERE EVER BE MORE THAN 3 MINOR AND (1) WATER CLOSET
VENTED ON LESS THAN A 2" VENT, A WASHER WILL NEVER DRAIN PAST ANOTHER TUB/OR
SHOWER USING THE SAME UPSTREAM VENT, AS WELL AS A WATER CLOSET WILL NEVER
DRAIN PAST A TUB/OR SHOWER USING SAME UPSTREAM VENT, BATH VENTS TO TERMINATE
THROUGH ROOF VENTS OR SOFFIT 3' MIN. FROM WINDOW AND DOOR OPENINGS.,
REVISION AND DATE
LEGEND
PROPOSED WOOD LOAD BEARING WALL (STUDS 16" 0. C.)
PROPOSED 6" WOOD FRAME WALL
PROPOSED 4" WOOD FRAME WALT_
PROPOSED 2" WOOD FRAME WALL
INFILL WITH STUDS OR CMU
PROPOSED 8" BLOCK WALL
b EXISTING ELECT. PLUG
PROP. ELECT, PLUG G.F.I.
PROP, ELECT, PLUG
NOTES:
NOTE: ALL CEILING DRYWALL SHALL BE "SAG RESISTANT
ELECTRICAL LEGEND
SYMBOL DESCRIPTION
�@
DUPLEX RECEPTACLE
X1/2 SX
1/2 SWITCHED DUPLEX RECEPTACLE
GFI
GFI PROTECTED RECEPTALCE
�GWP/Fi
WEATHERPROOF/GFI PROTECTED RECEPTACLE
s
SINGLE RECEPTACLE
220 VOLT OUTLET
_6cLc.
DUPLEX RECEPTACLE (CEILING MOUNTED)
$
SINGLE POLE SINGE THROW SWITCH
13
3—WAY SWITCH
11
4—WAY SWITCH
CEILING MOUNTED INCANDESCENT FIXTURE
H
SUSPENDED INCANDESCENT FIXTURE
O
RECESSED INCANDESCENT FIXTURE
wT
RECESSED WATERTIGHT INCANDESCENT FIXTURE
�E
RECESSED EYEBALL INCANDESCENT FIXTURE
I-�
FLOURESCENT LIGHTING FIXTURE
WALL MOUNTED FIXTURE
FLOOD LIGHT
TO
TELEPHONE
6
DOOR CHIMES
❑
PUSH BUTTON FOR DOOR CHIMES
TV
CABLE TELEVISION OUTLET
CEILING FAN LOCATION OR PREWIRE
sD
SMOKE DETECTOR
—OO
THERMOSTAT !
CD
CARBON MONOXIDE DETECTOR
LEGAL DESCRIPTION
LOTS 30, 31 AND 32 BLK 9 RECORD COPY
DREAMWOLD, PB 3 PG, 90
PARCEL I.D.#:
01-20-30-504-0900-0300
SCOPE OF WORK
CONSTRUCT PROPOSED KITCHEN
AS INDICATED ON PLAN, NO NEW
FOOTAGE; ADDED TO STRUCTURE,
AREA TABULATION
TOTAL AREA 2,34.00 SQ. FT.
REVIEWED FOR CODE COMPLIANCE
.ARC -ORD BUILDING DIVISION
A PERyIIT ISSUED SHALL BE CONSTRUED TO BEA
- —_ -- -- LICENSE TO PROCEED WITH THE WORK AND NOT AS
PLANS EXAMINER AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET
AIDE ANY OF THE PROVISIONS OF THE TECHNICAL
BATE E C00ES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
`�L.OUIRING A CORRECTION OF ERRORS IN PLANS,
CONSTRUCTION OR VIOLATIONS OF THIS CODE