Loading...
HomeMy WebLinkAbout340 Red Rose Ln`�� r`' CITY OF SANFORD BUILDING & FIRE PREVENTION SEF 0 9 2015 PERMIT APPLICATION Application No 1 .5- a ss* Documented Construction Value: $ Job Address: 3 in, R d POSE LiV 3'7( 818. 3'7 Historic District: Yes ❑ No Parcel ID: 21-19-30-5TT-0000- D I -a 0 Residential ❑ Commercial ❑ Type of Work: New n Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: NEW SINGLE HOME LN2.,611 2 -0o&6 - (A C3 -(AC3 Plan Review Contact Person: Daphne Clerk Title: Phone: 407-257-6940 Fax: Email: daphne Per, mitsPermitsPermits,com Property Owner Information Name TAYLOR MORRISON OF FLORIDA INC Phone: 407-629-0077 Street: 151 SOUTHHALL LANE # 200 Resident of property? : NO City, State Zip: MAITLAND FL 32751 Contractor Information Name JOHN ASA WRIGHT / TAYLOR MORRISON OF FLORIDA Phone: 407-257-6940 Street: 151 SOUTHHALL LANE # 200 Fax: City, State Zip: MAITLAND FL 32751 State License No.: CBC1257462 p Arch itectlEng ineer Information Name: 1 l)ll 414 i fy / Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: N/A Mortgage Lender: N/A Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105,3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. GENERAL NOTES INDEX OF DRAWINGS FOUNDATIONS METAL COATINGS FOR USE WITH PRESSURE TREATED WOOD - • SHEET SHEET TITLE SOIL UNDER SLABS AND UNDER FOOTINGS TO BE COMPACTED TO AT LEAST 95% OF IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS; MAX.DRY DENSITY AS DETERMINED BY ASTM- 1557 MODIFIED PROCTOR MINIMUM METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL ( ) BEARING CAPACITY 2000 PSF AND/OR HAVE THE APPROPRIATE COATING FOR USE WITH THE DIFFERENT TYPES TERMITE TREATMENT OF PRESSURE TREATED WOODS, AS PER THE FOLLOWING GUIDELINES. 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BEA MINIMUM G50 ZINC COATING THE SOIL UNDER THIS STRUCTURE SHALL BE TREATED FOR THE 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE PREVENTION OF SUBTERRANEAN TERMITES, OR A PERIMITER TREATMENT NON -DOT TREATMENTS: CONNECTORS SHALL BE A MINIMUM G185 ZINC COATING. (BORACARE) MAY BE USED, IN ACCORDANCE WITH RULES AND LAWS ( ) ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND 3. FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE CONSUMER SERVICES. PRESERVATIVE WOOD TREATER. 4. STAINLESS STEEL CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES CAST IN PLACE CONCRETE OF PRESSURE TREATED WOOD. PREFABRICATED WOOD TRUSSES 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF TED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR ENTRAINMENT, 1: ALL PREFABRICATED AND A MAXIMUM WATER/CEMENT RATIO OF p.5$. SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS. UPLIFT. CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS 2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR CONFORMING TO ASTM A-615 GRADE 40. LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN CONNECTORS APPLIED. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. THE LOCATION OF THESE WALLS AND STRUCTURAL PLANS FOR MORE INFO. 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND TRUSSES TO DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE "SPECIFICATIONS FOR STRUCTURAL CONCRETE.FOR BUILDINGS," ACI 301, DESIGN TO BE CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING SPECIFIED OTHERWISE BY TRUSS ENGINEER OF RECORD BEND) AROUND CORNERS OR CORNER BARS WITH MIN. 24" LAP EXCLUDING BEND 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH AT EACH END SHALL BE PROVIDED. THE LATEST EDITION OF ANSI TPI 1./� 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE 48 BAR DIAMETERS. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY TRUSS 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE MANUFACTURER UNLESS NOTED ON PLANS CENTER TO UPPER 1/3 OF THE SLAB.SD5 5. TRUSS ELEVATIONS AND. SECTIONS ARE FOR GENERAL CONFIGURATION OF BOLTS AND THREADED RODS TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY O BE ASTM A30 OR BETTER U.N.O. TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. 1. ALL BOLTS &THREADED RODS T 7 (U.N.O.) US 2. STEEL BOLTS LESS THAN ONE -HALF-INCH (12.7 mm) IN DIAMETER USED AS TRUSS DESIGN LOADS S i STRUCTURAL NOTES S2 FOUNDATION PLAN S3 DOWEL V EL PLACEMENT PLAN �+ S4 FIRST FLOOR FRAMING PLAN S4.1 NOTES a CONNECTOR LEGEND S4.2 ROOF FRAMING P LAN S5 LINTEL PLAN SD 1 FOUNDATION DETAI S S D2 q GENERAL DETAILS SD3 GENERAL DETAILS SD4 GENERAL DETAILS 0 TWO O STOR I DETAILS S D6 + �/ /� TWO STO R 1 DETAILS STORY ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. U FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. TOP CHORD: Lr = 16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) ST 1 W - • MASTER UPDATES W 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE Oz Q < CV 0 0 -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA „ „ PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2 CLEARANCE TO INSIDE FACE. RECOMMENDATIONS FOR MIN. 7/16 OSB SHEATHING 'D ALONGSIDE TRUSS TOP CHORD ROOF HIP/RIDGE -MIN 2x SYP #2 BLOCKING REQ @ wiF ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MINIMUM FLOOR DESIGN LIVE LOADS: z A)FLOORS = 40 PSF _ B) BALCONIES. - 60 PSF / 100 PSF (WHEN BALCONY EXCEEDS 100 SQ FT) L DATE DESCRIPTION w. 1 HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT GRADE N TYPE 2 C)DECKS = 40 PSF 8. HOOKS AT THE TOP &BOTTOM OF VERTICAL REINFORCING BARS TO BOND LCL 0 w°0 Um - N GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI 63 SECTIONS 1 , 2AND3 ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. U U U) O PERPENDICULAR TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS w W CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. ONE TRUSS SPACE (24) PLUS 6„ MIN PAST BOTTOM CHORD. E ACROSS TRUSS WEBS -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRAC (C LB ) 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING 0 CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR W 13. DO NOT APPLY UNIFORM (LOADS TO MASONRY WALLS FOR 3 DAYS AND NO O J Y PER CODE ACI 318 LATEST EDITION 5.11.1 CONCENTRATED LOADS FOR (7) DAYS. W 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ 12d TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND. M HT I S THAN 12" TALL: 2x4 SYP #2 INDICATED BLOCKING. ALTERNATE 1F HEEL HEIGHT S LES OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" 0 J -BOLT TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. TOP CHORD: Lr = 16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) ST 1 W - • MASTER UPDATES ;, 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE Oz „ SIZE OF 3/8 AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. 0 BOTTOM CHORD: DL = 5 PSF 0 0 -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA „ „ PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2 CLEARANCE TO INSIDE FACE. RECOMMENDATIONS FOR MIN. 7/16 OSB SHEATHING 'D ALONGSIDE TRUSS TOP CHORD ROOF HIP/RIDGE -MIN 2x SYP #2 BLOCKING REQ @ wiF ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MINIMUM FLOOR DESIGN LIVE LOADS: -- A)FLOORS = 40 PSF _ B) BALCONIES. - 60 PSF / 100 PSF (WHEN BALCONY EXCEEDS 100 SQ FT) L DATE DESCRIPTION INTIALS 1 HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT GRADE N TYPE 2 C)DECKS = 40 PSF 8. HOOKS AT THE TOP &BOTTOM OF VERTICAL REINFORCING BARS TO BOND LCL COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND w°0 Um - N GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI 63 SECTIONS 1 , 2AND3 ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. U U) O PERPENDICULAR TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS U W CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. ONE TRUSS SPACE (24) PLUS 6„ MIN PAST BOTTOM CHORD. E ACROSS TRUSS WEBS -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRAC (C LB ) 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING 0 CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR W 13. DO NOT APPLY UNIFORM (LOADS TO MASONRY WALLS FOR 3 DAYS AND NO O J Y PER CODE ACI 318 LATEST EDITION 5.11.1 CONCENTRATED LOADS FOR (7) DAYS. W 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ 12d TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND. M HT I S THAN 12" TALL: 2x4 SYP #2 INDICATED BLOCKING. ALTERNATE 1F HEEL HEIGHT S LES OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" 0 J -BOLT TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS W Of 6. MORTAR JOINTS NOT. -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCK AFFECTED (NO VERT. REINF. REQ'D) 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCK AFFECTED ON MASONRY IS TO BE PRESSURE TREATED. LL 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, WOODEN TOP PLATES. > 10. SEE PLAN FOR STUD PACK AND BEAM NAILING PATTERNS -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 L VERT. REINF. IN EA. CELL, CONT. PER PLAN. ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN 7. OVERHANGING CMU WALL VALUES AS FOLLOWS: -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. COLUMNS BEAMS STUD 2 2 2 U:N.O. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/2", GROUT FILL FIRST (3) COURSES LL Fb = 2500 Fb = 3000 Fb = 2200 -FOR CMU OVERHANGING FOUNDATION OVER 1-1/2", CONTACT EOR FOR REPAIRS. FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. TOP CHORD: Lr = 16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) ST 1 GENERAL STAIR DETAILS - • MASTER UPDATES ;, 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE B) BALCONIES =15 PSF „ SIZE OF 3/8 AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. COATED OF MECHANICALLY DEPOSITED Z NC- STEEL WITH COATING WEIGHTS IN BOTTOM CHORD: DL = 5 PSF -ADDIT'L BRACING &BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DRAWINGS FILLED WITH COARSE GROUT AND GRADE 40 STEEL. REINFORCEMENT SHALL BE -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA „ „ PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2 CLEARANCE TO INSIDE FACE. RECOMMENDATIONS FOR MIN. 7/16 OSB SHEATHING 'D ALONGSIDE TRUSS TOP CHORD ROOF HIP/RIDGE -MIN 2x SYP #2 BLOCKING REQ @ 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MINIMUM FLOOR DESIGN LIVE LOADS: CONSTRUCTION MASONRY WALL CO A)FLOORS = 40 PSF _ B) BALCONIES. - 60 PSF / 100 PSF (WHEN BALCONY EXCEEDS 100 SQ FT) NUMBER DATE DESCRIPTION INTIALS 1 HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT GRADE N TYPE 2 C)DECKS = 40 PSF 8. HOOKS AT THE TOP &BOTTOM OF VERTICAL REINFORCING BARS TO BOND „ „ IN ALONG TRUSS SPAN 10'-0" MAX AND TRUSS MEMBER w/ (3) 12d NAILS. SPACE X BRACING L S @ COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND " S�C EQUALLY SPACED FROM END OF TRUSS. X BRACING TO START 20'-0"MAX FROM HIP l CONFORMING TO ASTM C90, W/ A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 D) STAIRS = 40 PSF . 60 U.N.O. 6/3/20'15 CREATED ELEV. A,B,C AND MINOR OPTIONS EA PSI fm =1900 PSI E BONUS ROOM/GAME ROOMS = PSF 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 MINIMUM FLOOR DESIGN DEAD LOADS: 3. HEAD MORTAR JOINTS AT PRECAST WINDOWSILLS TO BE NO MORE THAN 1". A)FLOORS = 15 PSF 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE B) BALCONIES =15 PSF „ SIZE OF 3/8 AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. GENERAL TRUSS BRACING &BLOCKING REQUIREMENTS 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS.. -ADDIT'L BRACING &BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DRAWINGS FILLED WITH COARSE GROUT AND GRADE 40 STEEL. REINFORCEMENT SHALL BE -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA „ „ PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2 CLEARANCE TO INSIDE FACE. RECOMMENDATIONS FOR MIN. 7/16 OSB SHEATHING 'D ALONGSIDE TRUSS TOP CHORD ROOF HIP/RIDGE -MIN 2x SYP #2 BLOCKING REQ @ 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK TO PREVENT SHEATHING SPAN FROM EXCEEDING 2FT NOT REQ'D IF SHEATHING SPAN IS ` WALL AT THE TOP & BOTTOM & MAXIMUM 8'-0" U.N.O. VERITCALLY. TIES TO THE LESS THAN 2FT . BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS @ 12" O.C. MAX & 4" FOOTING & LINTEL STEEL IS ADEQUATE @ TOP & BOTTOM OF WALL; REBAR FROM EA. END. NOTE: PLYWOOD EDGES @ HIP CORNERS REQUIRE MIN 2x4 SYP #2 POSITIONERS IN MIDDLE OF WALL POS ,, BLOCKING w/ (3) 12d TOENAILS EACH END.. a- 7. REINFORCING STEEL SHALL BE LAPPED MIN. 25" U.N.O. -TRUSS "X" BRACING`. MIN 2x4 SYP #2 AT ANGLE APPROX. 450 FROM VERT. TO EA. 8. HOOKS AT THE TOP &BOTTOM OF VERTICAL REINFORCING BARS TO BOND „ „ IN ALONG TRUSS SPAN 10'-0" MAX AND TRUSS MEMBER w/ (3) 12d NAILS. SPACE X BRACING L S @ COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND " S�C EQUALLY SPACED FROM END OF TRUSS. X BRACING TO START 20'-0"MAX FROM HIP l 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED - N GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI 63 SECTIONS 1 , 2AND3 ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING "x 11. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL PERPENDICULAR TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO DESIGN DRAWINGS. ATTACH W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. ONE TRUSS SPACE (24) PLUS 6„ MIN PAST BOTTOM CHORD. E ACROSS TRUSS WEBS -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRAC (C LB ) 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING AS INDICATED ON TRUSS SHOP I -'DRAWINGS & BCSB3. CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR „ PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS (T BRACING MAYBE USED I.L.O. 13. DO NOT APPLY UNIFORM (LOADS TO MASONRY WALLS FOR 3 DAYS AND NO O - WEB (SEE WEB REINFORCEMENT TABLE WITHIN SCSI 63). Y PER CODE ACI 318 LATEST EDITION 5.11.1 CONCENTRATED LOADS FOR (7) DAYS. -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ 12d TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND. ENSURE PROPER CONCRETE EITHER RODDING OR PENCIL VIBRATOR TO R O HT I S THAN 12" TALL: 2x4 SYP #2 INDICATED BLOCKING. ALTERNATE 1F HEEL HEIGHT S LES CONSOLIDATION. BEHIND THE TRUSS VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN WOOD CONSTRUCTION BOTTOM TO TOP W/ (2) 12d NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) WIND EXPOSURE B DIAGONAL BRACING REQUIRED AT CLB PER BCSI-133. 1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA "NATIONAL DESIGN 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, SPECIFICATION FOR WOOD, CONSTRUCTION", LATEST EDITION.(NDS) BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL 2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS. SHEAR WALLS AND MISC. SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS STRUCTURAL WOOD FRAMING MEMBERS. (I.E. BLOCKING OR GABLE END BRACING), HANGERS. FIELD REPAIR NOTES SHALL BE SPRUCE- PINE -FIR OR EQUIVALENT. NO.2 GRADE SHALL BE USED AREA (SQ FT) REGARDLESS OF SPECIES U.N.O. ON FRAMING PLANS OR DETAILS. END -JOINTED 1. OMITTED REBAR LUMBER IS NOT PERMITTED TO BE USED IN ANY LOAD BEARING (GRAVITY OR WIND) DRILL A 3/4" O HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL #5 BAR CONDITIONS. E.O.R. TO REVIEW IF INSTALLED. INTO EPDXY FILLED HOLE. EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW 3. FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO 4. THE PORTIONS OF GLUED -LAMINATED TIMBERS THAT FORM THE STRUCTURAL MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND ARE EXPOSED TO WEATHER 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING AND NOT PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BEND). BE PRESSURE TREATED WITH PRESERVATIVE, OR BE MANUFACTURED FROM 2. STRAPS/CONNECTOR SUBSTITUTION NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD. MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY & LATERAL RESISTANCE VALUES IN FIELD W/OUT VERIFICATION, PROVIDED ALL MANU'S (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY INSTALLATION INSTRUCTIONS ARE FOLLOWED. SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE 3. STAIR CONSTRUCTION DESIGNED AND DETAILED BY OTHERS. 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE 6. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE USED FOR RISERS & TREADS ILO 2xl2'S (SEE GEN. STAIR DIETS FOR ADDIT'L INFO.) CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHEILDS. ALL 4. METAL STUD SUBSTITUTION HOLES OVER 1" IN DIA FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS SIMPSON HSS2 STUD SHOES, TYP U.N.O. 5. OMITTED J -BOLT 7. MANY OF THE PRESSURE TREATED WOODS USE CHEMICALS THAT ARE -1/2" ALL THREAD w/ WASHERS MAY BE USED ILO 1/2" J -BOLTS w/ WASHER DRILL & EPDXY CORROSIVE TO STEEL. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY THE TYPE w/ SIMPSON SET EPDXY @ 5" MIN EMBED. OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" CORROSION. FOR EXAMPLE. ACQ-C, ACQ-D, CBA -A OR CA -13 REQUIRE HOT -DIPPED J -BOLT TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS GALVANIZED OR STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SBX) DOES 6. MORTAR JOINTS NOT. -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCK AFFECTED (NO VERT. REINF. REQ'D) 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCK AFFECTED ON MASONRY IS TO BE PRESSURE TREATED. EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, WOODEN TOP PLATES. THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG 10. SEE PLAN FOR STUD PACK AND BEAM NAILING PATTERNS -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 ENGINEERED LUMBER VERT. REINF. IN EA. CELL, CONT. PER PLAN. ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN 7. OVERHANGING CMU WALL VALUES AS FOLLOWS: -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. COLUMNS BEAMS STUD 2 2 2 U:N.O. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/2", GROUT FILL FIRST (3) COURSES IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN Fb = 2500 Fb = 3000 Fb = 2200 -FOR CMU OVERHANGING FOUNDATION OVER 1-1/2", CONTACT EOR FOR REPAIRS. Ft =1500 Ft =1700 Ft =1500 STRUCTURAL STEEL Fc 11= 3000 Fc 11= 3000 Fc 11= 2100 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = Fc= 900 Fc j = 900 Fc j = 450 j 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. Fv = 285 Fv = 285 Fv = 150 2. STRUCT. CONNECTIONS: ALL STRUCT. BOLTS TO BE A325N U.N.O. ALL A325N BOLTS WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC, SLIP CRITICAL (SC) CONDITION U.N.O. BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. z TO BE A307 THREADED ROD &CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CEILING CONSTRUCTION CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 1 . USE 1/2" CEILING OR SAG SISTANT BOARD FOR 24" O.C. FRAMING UNLESS SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE OTHERWISE SPECIFIED. PROVIDED TO EOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED 2. 5/8" TYPE "X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE LIVING SPACE IS ABOVE THE GARAGE. 3/6' UNO. 3. MINIMUM 7/16" OSB. EXPOSURE 1 SHEATHING TO THE UNDERSIDE OF THE ROOF 3. SUBMIT SHOP DWGS INDICATING ALL SHOP AND ERECTION DETAILS INC. PROFILES, TRUSSES IN THE LANAI AND ENTRY AREA. ALL PANEL EDGES ARE TO BE BLOCKED SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, SOLID W/ 2X4 #2 SYP. W/ (3) 10d TOENAILS EACH END. THE OSB. IS TO BE NAILED W/ FASTENERS, LOAD, AND TOLERANCES. 8d NAILS @ 4" O.C. AT ALL EDGES AND 8" O.C. IN FIELD. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY UNDER STAIR PROTECTION ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 -INCH INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). (12.7MM) GYPSUM BOARD. SUBMIT REPORTS TO ARCHITECT AND ENGINEER. DESIGN PRESSURES WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 139 mph WIND SPEED (ALLOWABLE) 108 mph WIND EXPOSURE B RISK CATEGORY 11 BUILDING TYPE V B ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/-0.18 WIND PRESSURE & SUCTION EFFECTIVE (PSF) WIND (+) VALUE DENOTES PRESSURE AREA (SQ FT) VALUE DENOTES SUCTION AREA O O 10 (+) 21.2 (+) 21.2 - 22.9 -) 28.3 0 (+) 20.2 (+) 20.2 20 (-) 22.0 0 26.4 O (+) 19.0 (+) 19.0 50 - 20.8 (-) 23.9 100 (+) -18.0 (+) 18.0 L0') �0 - 19.8 - 22.0 - GARAGE DOORS 9'-0" x 7'-0" 16'-0" x 7'-0" OO 4Wz' + + (-)20.9 (-) 19.7 WIND PRESSURE/ SUCTION DIAGRAM 5 5 4 4 a �✓ 5 51-1 a STANDARD DESIGN PRESSURE NOTES 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA BUILDING CODE 5th EDITION (2014). WIND SPEED IS BASED ON LINEAR INTERPOLATION FOR THIS SITE. 2. MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, 2 STORY HOME IS 30FT 3." MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND PRESSURES. 4. , "a" = END ZONE IS ONLY W/IN 5'-0" OF ALL EXTERIOR BUILDING CORNERS. 5. INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS AREA. OPENING PROTECTION REQUIRED. REFER TO SECTION R301.2.1.2 OF THE RESIDENTIAL CODE FOR SPECIFICATION REQUIREMENTS OF THE USE OF WOOD STRUCTURAL PANELS. REFER TO TABLE R301.2.1.2 FOR ATTACHMENT SPECIFICATIONS � VJ W H (� v W 0 Q Z � - LL O 0 LLu a O O Uw)0wdo H Zco Z0z00U L0') �0 OO 4Wz' W oa64 C o0 :s Z _ J Lu 0OLL Q ¢`ZO u) 10 _ W M Lw N. J Q U z J W r � Z � V w 0 O 0 U Q LJ W z W ZWO 0 _ � O_ J w cn o. rn U v z 0 O Lu m 10 _ M ~ W r Z Q ZWO O_ J �_ cn o. 0 000 uj t0 z N m U) -j Z w� 0Wz --- W W >.00 --) QO= W 0 F- F- � U tr F- U STRUCTURAL ENG: CFG DRAFTING: z W -STRUCT: AML ... _ . QC CHECK: CC U) ..._......... ..._............ ..... ry JOB No. TM - 2151019 SCALE: AS INDICATED ~ DATE: 08-26-15 J08 J08 r C01 F01 F01 I -- F01 F01 C ■ F01 C < F01 C ■ F01 LD02 F01 J08 ■ F01 C F01 C -. F01 C F01 F01 F03 F03 C ■ F03 C ■ F03 F03 I F03 R04 R04 R04 FT ■ R04 R05 R05 R05 LD02 "' < CY) LD02 J08 D DO D ■ S1 SD2 U) U S1 D Z Z 0Lr. p J08 • ■ 1AD CL U EE LL LL SIM- USE 2x8 SYP U LD03 #2 LEDGER LD04 (5sim u- cli T- U p U04 . IN�i p SIM- USE 2x8 SYP SIM- USE 2x8 SYP #2 LEDGER #2 LEDGER W o� rr•rpsrrrs �%��% rrr w VI N o d;� w �r o .J = �< ♦Z1 BW1 Q PRd J /// O LL S1 O O ol�bJl v 0 u 0 O � o � z F� O am z Q J 0- / o U) U W J ~ z rn � w 0uJ E v 0a�;�.= Z p _ O 2 Lu LuZco,� J((,/)) 0!ZEEo c LL _ ¢ Opts ca _� LL U) Z¢ U z Z ,^r/ Ii O Q N J Cli W O � LL vNa F- 0 F09 J 2 H LUW G) 0 m rr W r Z Z W 0 N F09 0 0 w _ BW1 A BW1 w N m - F— _F LU 1 U J LL Q O W -) a o = 0 F-• F— ry CL STRUCTURAL ENG: CFG DRAFTING -STRUCT: AML QC CHECK: CC JOB No. TM - 2151019 SCALE: AS INDICATED DATE: 08-26-15 S4 BW1 BW1 BW1 W/ 1/3rd PT D0 B BLOCKING SD2 TIL --- -fl N2X12 - 1 -ti O O I+ O 00 O co O O M e- M e- M r M e- M r U a w U. w w LL LL U. w v F04 SIM- USE 2x8 SYP #2 Li LEDGER w/ (3) 1/4" x4 1J2 SIMPSON SDS SCREWS _ @ 24" O.C. -----.. n 2x6 STUDS o D0 LID r SD2 DO' p BW2 w-= H2XIS F1 F1 - S1 p p F1 F1 D 2x4 SYP #2 LEDGER TO TOP D p LIDO CHORD w/ (2) 1/4" x 3" SIMPSON D D��� GEO SDS SCREWS @ 4" O.C. cm L SIM. L � D B2x8 TOP @ 9'-4" � o CANTILEVER BEAM FOR 00 0 o c o o GABLE END BEARING o 0 B2x12 TOP @ 9'-4"� B2xl2 TOP @ 9'-4" ■ ■ y O O O O O O O O' O O J _Q z w Lu Of O N_ z O H ❑ w O w ❑ 0 c� z 0 J En 0 R O J w z F - LL O 1- U) w J EL 2 O U z Q ri w w IL Q 2 U LL O z O C m IL w a L o! C Q u; LL C z Q L C LL 2 H LL C z a C C L L a z C LL (r C a L z C a C C z LL c z a C LL z 9 LUL C cr LL U, a z LL C U, LL D! U, 2 W "' < CY) T— U) U Z Z 0Lr. CL U EE LL LL U o W o� rr•rpsrrrs �%��% rrr w VI N o d;� w �r o .J = �< ♦Z1 Q PRd J /// O LL O O ol�bJl v 0 u 0 O � o � z F� O am z Q J 0- z 0 U) U W J ~ z rn � w 0uJ E v 0a�;�.= Z p _ O 2 Lu LuZco,� J((,/)) 0!ZEEo c LL _ ¢ Opts ca _� LL U) Z¢ U z Z ,^r/ Ii O o0.wo Qa Q N J Cli W O � LL vNa F- 0 0 J 2 H LUW G) m rr W r Z Z W 0 0 0 w r 000 w N m F— 0 LU U J LL Q O W -) a o = 0 F-• F— ry CL STRUCTURAL ENG: CFG DRAFTING -STRUCT: AML QC CHECK: CC JOB No. TM - 2151019 SCALE: AS INDICATED DATE: 08-26-15 S4 L W JQ 0 N z w w U) STANDARD 2ND FLOOR FRAMING n j NOTES: 1. ALL EXTERIOR WALLS, LESS OPENINGS, ARE CONSIDERED SHEAR - Z O WALLS. U.N.O. ATTACH SHEATHING PER NAILING SCHEDULE. 0 1 2. AT ALL WINDOW/ DOOR OPENINGS @ 2ND FLOOR, CONTRACTOR i CL � � TO FOLLOW THE DETAILS INDICATED BELOW" Q OPENING SITTING ON MASONRY- WS06/SD5 (STRAPS CUl) W SHOWN ARE ONLY REQUIRED WHEN CALLED OUT ON PLANS OR SHEATHING ISNOT CONTINUOUS) OPENING SITTING ON WOOD BEAM- WS07/SD5 (STRAPS SHOWN ARE ONLY REQUIRED WHEN CALLED OUT ON PLANS OR vl\ SHEATHING IS NOT CONTINUOUS) 3. AT ALL CORNERS, CONTRACTOR TO FOLLOW WS09/SD5 U.N.O. SO w/ STRAPS ON BOTH SDS SIDES OF WALL WALL LEGEND h er dd d �1 M N > 0 0 0 0 0 0 0 0 0 0 o O 0 a o > n -� n -� n n �2- _._.._ T = 9'-4" T.O.M. = INTERIOR/EXTERIOR i w BEARING WALLS VERIFY W In 11 HGT. W/ ARCHITECTURAL '- w M H2X6 H2X6 H2X H — — H2X6 101 PLAN U.N.O. z r Q W 0 J02 EXTERIOR FRAME WALL O L Qui SCHEDULE o D Y J03 (TAYLQR MORRISON) 1 Oop Q co S0 D SD5 3 4 WALLS WITH PLASTER OR STUCCO FINIS CO �Nm WALL HEIGHT STUD & SPECIES SPACING 8'-0" 2x4 SPF #142 16" O.C. MAX uj W 9'-011 2x4 SPF #142 16" O.C. MAX U) 3 QO= 9'-4" 2x4 SPF #142 16" O.C. MAX p H I— 10'-0" 2x4 SYP #2 12" O.C. MAX EXTERIOR FRAME WALL NOTES _77 r 2x6 #2 SPF STUDS AT 1. 2x4 WALL STUDS WITHIN 5 FT OF EACH CORNER END ZONE ARE TO 16" O.C. U.N.O. BE 2 -PLY BUILT UP MEMBERS (SPECIES AND SPACING AS NOTED IN CHART ABOVE). SEE DETAIL WF08/SD4 FOR BUILT UP STUD NAILING i— �-- PATTERN. U) STRUCTURAL ENG CFG Q 2. SEE DETAIL WF10/SD4 FOR REQUIRED WALL SHEATHING AND NAILING PATTERN. 2.1. NOTE: CONTRACTOR TO TAKE CARE AND NOT OVER DRIVE Z -STRUCT. AML W NAILS. IF NAILS ARE OVERDRIVEN, THE ENTIRE SHEET OF -.� SHEATHING IS TO BE REMOVED ANDREPLACED. IF MORE THAN QC CHECK. CC 50% OF THE SHEATHING IS OVERDRIVEN, CONTACT EOR FOR TM - 2151019 SCALE: AS INDICATED REVIEW OF EXTERIOR STUDS ~ 3. SEE DETAIL WS02/SD5 FOR FRAMING REQUIREMENTS FOR DATE. 08-26-15 -_- — EXTERIOR 2x6 / 2x8 FRAME WALLS. 4. SYP #2 STUDS MAY BE SUBSTITUTED FOR SPF #1/#2 STUDS ONLY. 5. IF EXTERIOR FRAME WALL IS NOT SUPPORTING PLASTER OR 00 STUCCO FINISHES, FRAMER IS TO FOLLOW CHART ABOVE U.N.O. O � M � o 3 D BW2 H2X6 SO D 3 SD5 R18 R18 R18 ULTIMATE WIND SPEED: 139 MPH EXPOSURE: B — H2X6 R19 o 0 0 0 o Cl OV D GE0 D ROOF FRAMING PLAN 1/4"= 1 1-011 56 #15�a L71tVC ORD p,hJV ��• �� (�F. �1hA�`1� L W JQ 0 N z w w `rrr►r�tria,�e w "t k odono �b'••hti�4��s W o • r Z Q • • � Q U .CD � Q ' ® *• .; • , ••�• �C� a®® J U U) W 0 U ^ C +O z H I a C6 U tih,a; 3j o o O GG�_ O rr ll O iu iii'llill II,iii�r�V�.• Ci�v� z O > O Q w CL am LLI U I— U) z ❑ Q U J in U h 0 W J n o v rn Zw z FU � J E rn ¢ 0u_- Z Z U �prn�: Q W Z (05 -� J fA EE z a 0 0 W Z Q O Oo-) :s m _ Z<< Zto OE O OLL ¢a LN LL W N Q zJLL zo" O O LL U F- O Q W L.I. Z = Lij co n� 0 U) n j U - Z O 0 1 i CL � � W LL m Q CUl) W 0 0 U i w W In 11 = '- w M H W `rrr►r�tria,�e w "t k odono �b'••hti�4��s W o • r Z Q • • � Q U .CD � Q ' ® *• .; • , ••�• �C� a®® J U U) W 0 U ^ C +O z H I a C6 U tih,a; 3j o o O GG�_ O rr ll O iu iii'llill II,iii�r�V�.• Ci�v� z O > O Q w CL am LLI U I— U) z ❑ Q U J in U h 0 W J n o v rn Zw z FU � J E rn ¢ 0u_- Z Z U �prn�: Q W Z (05 -� J fA EE z a 0 0 W Z Q O Oo-) :s m _ Z<< Zto OE O OLL ¢a LN LL W N Q zJLL zo" O O LL U F- O Q W L.I. Z = Lij co n� 0 n z 0 1 ujo❑ Q 0 W In 11 = M H W z r Q W 0 Z O L Qui o D Y W 1 Oop Q co CO �Nm o V uj W U) 3 QO= p H I— U a. i— U) STRUCTURAL ENG CFG Q DRAFTING H Z -STRUCT. AML W QC CHECK. CC JOB No. TM - 2151019 SCALE: AS INDICATED ~ DATE. 08-26-15 NOTE: SEE PAGE S4.1 FOR NOTES AND CONNECTOR LEGEND S4.2