Loading...
HomeMy WebLinkAbout1500 Wyndham Crest Blvd (a)� D Applicatio Job Ad est Parcel CITY OF SANFORD DSC 0� 2013 BUILDING & FIRE PREVENTION PERMIT APPLICATION of 6/11 Documented Construction Value: Blvd . • Historic District: Yes ❑ Zoning: No)Q--- Description of Work: Ey4eriorllderier kcegirg Plan Review Contact Person: 6r# F... CADO Title: PresiJenf- Phone: 'f6If- 3S 4- 8797 Fax: 'foj- 381f-8791 E-mail: eri G o19 qfreno✓a4i a ^S. ee w, Property Owner Information Name The_ U Ise., Co.,...eay t, Phone: `f07- 780 - 075'f Street: 65S A104ft Fria,"lin sfreet- 544,k"X0o Resident of property? City, State Zip: FL 3 3 bo �2. Contractor Information Name &j F enoda4ionslnr. Eric Franco Phone: `F0`f- 1f71f, If 80 S Street: 1015 Union Hell Ri. St ti e- 7 Fax: TO 'f - ftFB-'tY-4 0 City, State Zip: A l p h are_& , 6A 30 o o r- State License.No.: C G C 15;Z 1 7 7 0 Architect/Engineer Information ccc 13A7a1?0 Name: E PI Phone: 384 - 734 - o Sao Street: 311-A S Woodland Blvd Fax: 3194- 73 4 - City, St, Zip: De far,rl FL E-mail: epi d e P e n a• n of Bonding Company: W esiern Surd-& CLg*l za Address: Si o u X Falls SO." Do -.k.. t-0. Building Permit O Square Footage: No. of Dwelling Units: Electrical D New Service — No. of AMPS: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: Mechanical ❑ (Duct layout required for new systems) No. of Stories: Plumbing O New Construction - No. of Fixtures: Fire Sprinkler/Alarm O No. of heads: -41I53. SS Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. AA14A__ !a] 33 13 Signature of Owner/Agent Date 50 ('i [)) L1-6 -' P6 Abbe rr;f- % Ei b /.>3 //J of Florida Date SUSAN F MYCOIYtM18 io` .4 IF CE, 90103 EXPIRES •d, 2010 Owner/Agent is Personally Know to Me r Produced ID Type of ID APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 UTILITIES: FIRE: /0 %3 .t of 3 Signature of tractor/Agent Date Ert'c Fra r, c o Print Contrad%i/Agent's Name 3 "$9 -VAN F LOMBARDO MY COMMISSION # EE180183 EXPIRES January 28.2018 Contractor/Agent isyPersonally Known to Me or Produced ID Type of ID WASTE WATER: BUILDING: 1,1 - �'— Z/Z T -D CITY OF SANFORD e A 9nii BUILDING 8. FIRE PREVENTION �� a•30�� �3a3�� J PERMIT APPLICATION I y (//13'-,,y Ap#lication No: Lf — LI -3-3 Caes�- Documented Construction Value: $ 150010 WyndhaWn Blvd. ' Job Address: 5a g4,, -d FL 3 2 773 Historic District: Yes ❑ No)@--- Parcel ID: A/-oZ0 - 30, 3C:o-- 7���7C)00 Zoning: Description of Work: EX.4e ri o r 44 n ertar Reoar t -_s Plan Review Contact Person: �ro'c. Frmhc.o Title: Preside jf- Phone: "f 61 - 38 4- S 7,1'7 Fax: `fo f - 381- 8787 E-mail: eri c 6 zrre,ova-li o nJ - co.,, Property Owner Information Name The u)ilse.,, Co,,pav, , Phone: `fol- 780 - 075`f `1 Street: 65s Afer+A Frianl4l n Sfrcet` Resident of property? City, State Zip: _ra,,pA FL 3 3 bo z- ContractorInformation Name G£ F I" C. Ar -i,= F r-arlw Phone: `FO`f - `f7`f, `f80 8 Street: 1015(Anion fhIIPJ. G"Me- 7 Fax: TO 'f - 'tf�B 0 City, State Zip: Al phare -H,*, 6A 3000i- State License No.: CG G 15;Z 1 -17 0 Architect/Engineer Information ccc 13A7a8o Name: EPI Phone: 384 -• 734f - 0 830 Street: 311-14 S Woodland Blvd Fax: 3 l? 4- 73,f-- k Q a City, St, Zip: De (and FL E-mail: ee d e P l e n a n of J Bonding Company: LJO-Sfern Sural Corw,cY� Address: .Si -o u x FQII S So -+k DoJc.- t-41- Building -0. Building Permit ❑ Square Footage: No. of Dwelling Units: Electrical ❑ New Service - No. of AMPS: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing ❑ New Construction - No. of Fixtures: Mechanical 13 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a .separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, .tanks,land air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. R31 13 Signature of Owner/Agent Date 1�Pe r,'< Lfi LSo " AS Al Print Owner/ ent' ame S' a ure o N tarv-Slate of Florida Fla 'TW C- `7� SUSAN F 1 00 &.0 MYCOMMIBSIo. V %EXPIRES 2018 i�— RtoAEaNvfny y.eMl � /-�3 Owner/Agent is Personally Known to Me r Produced ID &7 -Type of ID ,c— APPROVALS: ZONING: C& UTILITIES: COMMENTS: Rev 11.08 /o /,;?3LAo13 Signature of ntractor/Agent Date Ert'c Fra n c o Print Conti-46o)/Agent's Name bit S &rg�a—I.Kc o o tooUIAN LOMRDO W MY COMMISSION# EE1e0183 EXPIRES January 28,2010 oero Contractor/Agent is 1--�Personally Known to Me or Produced 1D Type of 1D ENGINEERING: aalla FIRE: WASTE WATER: BUILDING: �r e TD CITY OF SANFORD ,j� n Dntl BUILDING & FIRE PREVENTION "`� 4V PERMIT APPLICATION t _ L Hyl / 3�• � Application No: ` �CiLc''S L Documented Construction Value: $ A&,aa* 1500-0 u) y n d Nary, 51"j. Job Address: 5 n -A.. -d Ft.. 32773 Historic District: Yes ❑ No)95" Parcel ID: Zoning: = a Description of Work: Ey4eriorL-Tn4eri' r• Pepae, #-_s Plan Review Contact Person: Ery c Frmrw Title: Preside.•,% Phone: If e`f- 38`F- S7g7 Fax: `fo`F- 391-87g1 E-mail: erc'c oPgf'renovc-lions- co,,., Property Owner Information Name The U)i Ise.,, Co w.Pa"..y Street: 45s A164A Franl4jin Sfrcet" City, State Zip: �avwpA FL 3 3 6o -3- Phone: `f07- 7 g - 015T• Resident of property? : Contractor Information Name G£_F genoya- l'aoslnc. lEric Frar cp Phone: `tO f - `f71f -- If 80 8 Street: 1015 (/inion WO R8. St ije_ 7 Fax: `tO `f — 'f `f `f4 0 City, State Zip: Alphdre-VA, 6A 3000Y- State License No.: CGC 15;Z 1 -7 70 Architect/Engineer Information ccc 13A7a8o Name: E Py- Street: =Street: 311 -A S W o o d IQ n d 641d City, St, Zip: Dela„ 4 Ft: Bonding Company: W esfern .Sure e0n;4j� Address: Si -o u x Fan's So.." Doic.. t a - Building Permit ❑ Square Footage: No. of Dwelling Units: Electrical ❑ New Service — No. of AMPS: Phone: 384 734- 0930 Fax: 3F?4 - 7.31f- 9.R a lr E-mail: epi G e P l e n u of J Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing ❑ New Construction - No. of Fixtures: Mechanical 13 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan.review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. X13 11-3 Signature of Owner/Agent Date Print of Florida Date SUSAN F I ' t'!.., :L:iDD MY COMMWit "4 " E'r-90103 EXPIRES Jr^•.:too •-.d, x4018 4. b /.>3//? Owner/Agent is Personally Known to Me r Produced ID Type of I D - ,c.._ APPROVALS: ZONING: UTILITIES: COMMENTS: Rev 11.08 /0 /3 Signature of ntractor/Agent Date Ert'c Fra in c Print Contr o /Agent's Name Ab�V ' S 3 1gnatt e o 0 �� ° §�(�AN !F LOMWtta 'A �-.� •'? MY COMMISSION # EE190183 EXPIRES January 28.2018 ' t�otroe .oem Contractor/Agent is Personally Known to Me or Produced ID Type of ID WASTE WATER: ENGINEERING: FIRE /Zh� BUILDING: i DED 18 2013 ` CITY OF SANFORD ' BUILDING & FIRE PREVENTION PERMIT APPLICATION I��r Application No: Documented Construction Value: $ .�!�'iyd tom"' Job Address: I5W 1nJ k v4 qK, Ores T 4e Vd Historic District: Yes ❑ No ❑ Parcel ID: /i Zoning: Description of Work: rv�Sf'�U' �e��l� �ry t."ulL"e Ta)GiC Plan Review Contact Person: Title: Phone: Name Street: City, State Zip: Fax: E-mail: Property Owner Information Phone: Resident of property? : Contractor Information Name er City, State Zip: :�f'n"4 Fr Phone: �Ia?-3 0- Fax: State License No.: Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Address: Building Permit ❑ Square Footage: No. of Dwelling Units: Electrical d— New Service — No. of AMPS: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing ❑ New Construction - No. of Fixtures: Mechanical 13 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced 1D Type of ID APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 UTILITIES: Fl RE: S nature of Comraclor/Agent Date Prin ntractor/Agent's No e Mull AA All R" d I� Signature of Not aiy_ ••. %� Date .151 :bI dw.o NO Contractor/A .;,. je`ohally Known to Me or Produced ID tfr/,y,tID FL DC - WASTE WATER: BUILDING: ` . .Estiffla Trade Contractor Agreement GENERAL CONTRACTOR: Company Name: G&F RENOVATIONS INC Business Address: 1015 Union Hill Rd Suite 7 Alpharetta GA 30004 Trade Company Name (as it appears pn check): �( L9 nA Q ! E l T!i t _TYMC 5 i /yt ct•1 a -Ir (2.145 Corporation: % Partnersh Sole Proprietorship: Name of Owner. Partner, President: IT(e_ C Ir - �k r Title: nuJn Business Address (include city, state. zip): 4y Z• Business Phone: 1407—?Ay-M) Business Fax: Al, _ 7 S Cell Phone: - Pager/Nextel No.: Email: S&IJ*A1iAi1bsite: SSN: or Federal Tax ID: G&F RENOVATIONS INC (hereinafter "General Contractor" AND/OR "GC") and ,SCt J et n ion,, In -T-_i e r +,,- c sn C • (hereinafter "Sub - Contractor") enter into this agreement (hereinafter "Agreement") on this 19 day of I,- , e,yn , , , 20_UI_. 1. Proiects: The Agreement applies to all projects (hereinafter "Project(s)") for which Sub - Contractor hereinafter provides Work to General Contractor, except for those that are already subject to another agreement between the parties. The term "Project(s)" includes the properties on which renovations or construction is occurring. 2. Work: For all Projects, Sub -Contractor agrees to provide all materials, labor, tools, equipment, supervision, supplies and other items necessary or required to perform the work that is described in general on the attached Scope of Work and/or Bid Sheet. The Scope of Work and/or Bid Sheer., together with any signed and written supplements or modifications thereto for particular Projects, are incorporated into the Agreement, and shall hereinafter be referred to collectively as the "Work." I Construction Standards: Sub- Contractor commits to the goal of performing the Work according to the highest standards of skill and workmanship and with "zero defects." Sub -Contractor agrees to perform all Work in full compliance with or exceeding the requirements of all of the following standards (hereinafter "Construction Standards"): (a) plans, drawings or specifications provided by General Contractor for a particular Project: (b) applicable federal, state, county and municipal codes, regulations, rules and laws: (c) applicable manufacturer specifications, directions and suggested methods; (d) private restrictions and covenants; (e) subdivision or homeowner association rules or Grnrul I ..nu,.,. nor Innup r M,b•l •onV+. k., Ona a it - /Pa nt regulations; (f) any written warranty provided or to be provided by General Contractor to Owner; (g) at least ordinary standards of care under the circumstances; (h) requirements of the Federal Housing Administration or Veterans Administration; and (i) standards set forth in the Scope of Work and /or Bid Sheet or any supplements or modifications thereto. General Responsibilities: In addition to its other responsibilities under this Agreement, Sub -Contractor shall have the following responsibilities: Sub -Contractor shall procure and pay for all permits, licenses, and inspections required by any governmental authority for any part of the Work and shall furnish any bonds, security, or deposits required by such authority to permit performance of the Work. Sub -Contractor shall be also abide by all Regulations Standards from OSHA, and will be responsible for any penalties, fees, fines and/or payments of fines imposed if him/her or any of his/her people are in violation of its regulations. Sub -Contractor shall comply with, and insure the compliance by its employees, other subcontractors and agents with, all applicable federal, state and local laws, ordinances, statutes, rules, and regulations, including those relating to wages, hours, fair employment practices, nondiscrimination, immigration and naturalization, occupational safety or health and working conditions. The safety of Sub -Contractor's employees, subcontractors and agents, whether or not in common work areas, is the responsibility of Sub -Contractor. C. Sub -Contractor shall visit each Project before starting the Work to understand conditions relating to such Project, including access restrictions to the Project. d. Sub -Contractor shall coordinate the installation of the Work with other interfacing trades in a courteous and professional manner, so as not to interfere with them, delay them or damage their work. e. Sub -Contractor shall conduct the Work so as to avoid causing damage to any part of a Project. Sub -Contractor shall be responsible for all such damage. f. Sub -Contractor shall provide a qualified onsite supervisor whenever the Work is being performed. g. Sub -Contractor shall keep Projects clean of dirt, debris, trash, and any waste materials arising from the performance of the Work. Sub -Contractor is responsible for placing all trash and any construction debris created as a result of the Work in the area designated by the General Contractor. h. Sub -Contractor shall not remove or damage silt fencing or other erosion control devices. C- Vagi Sub -Contractor shall keep all vehicles off Projects, including driveways, unless expressly permitted by General Contractor to drive onto a Project for a limited purpose. Sub -Contractor shall not use or permit the use by any of its employees, subcontractors, suppliers or agents of alcoholic beverages or controlled substances on or in connection with the Project or the Work. Sub -Contractor shall not cover any known defect in the Work or in work by someone else, but shall immediately notify General Contractor of such defect and obtain permission to continue the pertinent aspect of the Work. Sub -Contractor shall not allow food or smoking inside of a Project. M. Sub -Contractor shall not allow shoes to be worn inside of a Project with finished flooring installed. n. Sub -Contractor shall not permit profanity, loud conversations or music, or other behavior likely to disturb others working on a Project or persons living in proximity to a Project. o. Sub -Contractor understands that it is not authorized to make changes in the Work at the request of any third party without obtaining written direction from the General Contractor per the Agreement. Any requests for changes should be referred to General Contractor. P. Sub -Contractor shall limit its interactions with residents or potential tenants and realtors so as to avoid confusion between Owners and these persons and shall refer questions from them to General Contractor or Leasing Agent. Sub - Contractor shall not offer them advice or opinions. q. Sub -Contractor shall immediately inform General Contractor of any change of its address or telephone numbers set forth above. Sub -Contractor is fully responsible, in contract and tort, for the performance of the Work that it subcontracts to anyone else. 5. Timing of Work: Sub -Contractor agrees to perform the Work in a timely manner and in accordance with the requirements of any construction schedule that General Contractor may from time to time develop and submit to Sub -Contractor. Within three (3) calendar days after being notified by GC. Sub -Contractor shall commence actual construction of the Work and shall thereafter diligently continue the Work to completion. If, in the opinion of GC, Sub -Contractor falls behind the schedule, General Contractor shall take steps as may be necessary to accelerate the Work. (.rnrr�l (.mrn.6 . 11,111JI, r. 1 _ _ 1111.. ,mlr.a for Inm.d.__ pap .• 6. Contract Price: The contract price and payment terms are set forth in the Bid Sheet and shall remain in effect until the parties agree in writing to a new contract price or the Agreement is terminated. The Bid Sheet is attached as part of the Agreement. Payment Procedures: Applications: Sub -Contractor shall submit signed applications for payment to G&F Renovations Inc., on a schedule adopted by GC, which schedule shall allow applications at least every other week. The applications shall include an estimate by Sub -Contractor of the percentage of the Work completed. Contractor's submission of an application shall constitute a warranty and representation by Sub -Contractor to GC and Owner that Sub -Contractor has performed that portion of the Work covered by the application in full compliance with the Agreement, and has paid for all labor, materials, supplies, equipment, tools and other items used in performance of the Work, and it has obtained legally binding interim or final lien waivers from all such persons or entities. Builder may require proof of such payment and of such waivers prior to making payment to Sub -Contractor. The following individuals are expressly authorized by Sub -Contractor to sign applications for payment on behalf of Sub -Contractor: . G&F Renovations Inc. is not required to accept applications signed by anyone else. [ J If this box is checked, the Sub -Contractor shall also be required to submit along with applications a properly executed and legally enforceable Interim Waiver and Release upon Payment form or Waiver and Release upon Final Payment form, respectively, as permitted by the State where the "Property" is being performed "Work" is located. a. Payments: After reviewing an application, G&F Renovations Inc. shall pay Sub - Contractor the percentage of the Work that GC determines has, in fact, been completed. Such payments shall be made according to GC's pay schedule attached following timely submission of complete and accurate applications. Untimely or inaccurate applications will cause a delay in payment. 8. Warranty: Sub -Contractor warrants all Work against defects in labor and materials for a period of one year or, if longer, for a period coinciding with GC's warranty to Owner on any Project and to any subsequent owner of a Project if GC's Warranty extends to subsequent owners. Within three (3) working days after being notified of such defect by GC. Sub -Contractor shall remedy, at its own expense, any such defect, unless the defect requires emergency attention, in which case Sub -Contractor shall immediately address the defect, and Sub -Contractor shall pay any damages to GC, Owner or subsequent owner resulting from such defect. If Sub -Contractor fails to remedy any such defect, GC may do so and Sub -Contractor shall be liable to GC for all costs associated with performing such remedy. This warranty shall not limit Sub -Contractor's other obligations under the Agreement or law. 9. Insurance: Even if not required by law, Sub -Contractor shall maintain, on its own and at its own expense, the following in rance coverage's: (a) workers compensation t........., r... Im,...l. . PAP . insurance in the amount not less than $1,000,000 ; (b) general liability insurance minimum of $1,000,000; (c) property damage insurance; and (d) automotive public liability and automotive property damage insurance in an amount not less than: 1,000,000. (i) $1,000,000 for any one person; (ii) 51,000,000 for bodily injury for any one occurrence; and (iii) $1,000,000 for property damage for any one occurrence.. Each Certificate of Insurance shall name G&F Renovations Inc. as certificate holder and shall state that the insurance will not be canceled without thirty (30) days written notice to GC. The certificate for the general liability policy shall name G&F Renovations Inc. as an additional insured. Sub -Contractor shall deliver to GC, without expense to GC, certificates from Sub -Contractors insurance companies or broker prior to commencement of work and along with this signed agreement. 10. Indemnification: Sub -Contractor agrees to indemnify and hold harmless Contractor, as well as its shareholders, directors, members, volunteers, officers and employees, from any claims, damages, losses, expenses or fines, OSHA fines, including attorney's fees and legal expenses, arising out of or resulting from either a breach of the Agreement or any negligent or intentional act or omission by Sub -Contractor or its employees, subcontractors, suppliers or agents other than for bodily injury to persons or damage to property caused by or resulting from the sole negligence of Sub -Contractor or its agents or employees. 11. Dispute Resolution: Except as hereinafter provided, any dispute between General Contractor and Sub -Contractor arising out of or relating to the Agreement shall be resolved by mandatory, binding arbitration in the courts of the State where the "Property" it's being "Worked" at, is located, and in accordance with the rules of Construction Arbitration Associates, ltd. in effect at the time of the initiation of the arbitration and the decision of such arbitrator shall be final and enforceable in any court having jurisdiction. However, if General Contractor is a party in either litigation or arbitration, before the same or a different arbitration entity, involving claims between GC and any Owner or Tenant of a Project that arise out of or relate, in whole or in part, to the Work required by this Agreement or any obligation of Sub -Contractor under this Agreement, Sub -Contractor agrees that GC may bring Sub -Contractor into such litigation or arbitration as a third or additional party in order to assert claims against Sub - Contractor relating to such Work or obligations, including claims for indemnity or contribution. The results of any such arbitration shall be binding and enforceable in a court of competent jurisdiction. This paragraph shall apply to disputes covered by it even if the Agreement is terminated or rescinded. 12. Independent Contractor Status: Sub -Contractor is an independent contractor of General Contractor and is not an employee of G&F Renovations Inc. Sub -Contractor will withhold from its payrolls as required by law or government regulation and shall have full and exclusive liability for the payment of any and all taxes and contributions for unemployment insurance, worker's compensation, and retirement benefits that may be required by federal or state governments. 13. Breaches: Sub -Contractor shall be liable to General Contractor for all damages arising out of or relating to breaches by Sub -Co trac r under the Agreement. General i 4rneral C.rnrra, tw hauls � %U1,k ,wrarwr 1.11114k __ _ , Nge j Contractor is entitled to deduct such damages from payments otherwise due to Sub - Contractor under the Agreement and to pursue Sub -Contractor for any additional damages. 14. Termination: If Sub -Contractor breaches the Agreement and fails to cure such breach within three (3) business days following written notice from General Contractor, GC may terminate the Agreement completely or may, without terminating the Agreement, terminate Sub -Contractor from the Work on particular Projects on which such breach occurred. If GC terminates the Agreement or terminates Sub -Contractor as permitted herein, it shall be entitled, without waiving any other claim against Sub -Contractor, to retain so much of any funds that may otherwise be due to Sub -Contractor as are necessary to remedy such breach or to complete such work through other means. Either party is free to terminate the Agreement as to future Projects with written notice prior to the commencement of Work on such Projects. 15. Miscellaneous: The agreement does not give exclusive rights to Sub -Contractor to work with General Contractor. G&F Renovations Inc. may create agreements with other parties in the same trade without affecting the Agreement. a. The Agreement shall be governed by, and interpreted in accordance with the laws of the State where the Property it's being "Worked" at, is located. b. The Agreement is the entire agreement between the parties and can only be modified or amended in writing. C. No representation, promise or inducement not included in the Agreement is relied upon or shall be binding upon either party. d. Time is of the essence of the Agreement. e. Notices required in the Agreement shall be in writing to the other party at the address of such party set forth above and shall be given in person by overnight delivery service prepaid, by facsimile, or by certified mail, return receipt requested. Such notice shall be deemed given when received at such address. f. Each provision of the Agreement is severable from every other provision. If any provision is determined to be unenforceable, the rest of the Agreement shall remain valid and enforceable. g. All plans, drawings and specifications provided by General Contractor to Sub - Contractor shall remain the property of G&F Renovations Inc. h. The term "including," shall mean, including but not limited to the specific item or matter mentioned. r (n•u.•ul 1 ontrs ror bnlub __� r ?nb r onto. rnr In,urh rlf,'P A M Certification: Sub -Contractor certifies that it: (a) has read the Agreement and understands it; (b) has the skills and qualifications necessary to perform the Work in accordance with the Agreement, and to otherwise comply with the Agreement; (c) has all licenses, registrations and similar governmental authorizations necessary to perform the Work and to comply with the Agreement; (d) is familiar with all of the Construction Standards and applicable laws, rules, regulations, codes, documents and other matters mentioned in the Agreement; and (e) has the authority to sign the Agreement. The individual signing on behalf of Sub -Contractor represents and certifies that he is authorized to sign this Agreement on behalf of Sub -Contractor. 17. Protection of People and Property: Sub -Contractor shall be responsible for initiating, maintaining and supervising all safety precautions and programs in connection with the performance of the Contract. The Sub -Contractor shall take reasonable precautions for safety of, and shall provide reasonable protection to prevent damage, inquiry or loss to employees, the work materials and equipment to be incorporated therein; and the Property at the Site or adjacent thereto. Sub -Contractor shall abide by all rules and regulations of OSHA and will be responsible for any penalties, fees, and/or any fines imposed by this organization and release the GC of any responsibilities regarding violations of its regulations. 18. The Sub -Contractor shall give notices and comply with applicable laws, ordinances, rules, regulations, and lawful orders of public authorities bearing on safety of persons and property and their protection from damage, injury or loss. The Sub -Contractor shall promptly remedy damage and loss to property caused in whole or in part by the Sub -Contractor, or anyone directly or indirectly employed by any of them, or by anyone for which the Sub -Contractor is responsible. GENERAL CONTRACTOR COMPANY NAME: G&F RENOVATIONS INC. By: Print Name: t r i c l'Lt 11f C Title: 10 tP N t rl to "I t Date: -1 1�1J 19 2 t r i:rnrr.r� f .nnr.0 r..r hnba�, Y brt. r'..M nr r..r In.r..,l. Page SUB -CONTRACTOR COMPANY NAME: [Full Legal Name] By: jt Prirta: !I��_C 1od Te �nyY Title:'Qll�P.h� Date: kL_/_nJZ,Q\ j Savannah Electric Inc 699 Eldron ct FL 32738 Name / Address GF Renovations Steve Hall 1015 Union Hill Rd Suite 7 Alpharetta. Ga 3004 Wyndham Estimate Date Estimate # 11/18/2013 1245 Project Description Qty Rate Total Scope: Inspect and repair electrical system for 4 apartments affected 1 380.00 380.00 by fire Unit 8303: Use meghometer to verify all homeruns are ok and suitable for power. After meter is installed hot check complete unit. Unit 8304: Use meghometer to verify all homeruns are ok and I 380.00 380.00 suitable for power. After meter is installed hot check complete unit. Unit 8301: Replace 2 damaged romex wing. Use mcghometer to 1 650.00 650.00 verify all homeruns are ok and suitable for power. After meter is installed hot check complete unit. Unit 8302: Replace 5 damaged romex wires. Replace all phone and 1 1.650.00 1.650.00 cable tv runs. repair fire alarm circuits. Install customer supplied lights. Use meghometer to verify all homeruns are ok and suitable for power. After meter is installed. Hotcheck complete unit. I lallway: Install customer supplied lights restrap romex. 1 200.00 300.00 Price includes all problems seen upon inspection. If any other problems arc found GC will be notified immediately. Thank you for your business. Total S3.260.00 D ; CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION (y/ /3<; Cl Application No: �f — LI C s�- Documented Construction Value: $A6 1500V u3Yndi16tr." Blued. Job Address: 5a,,_4, -d FL_ 3 2 77.3 Historic District: Yes ❑ No,9'_-_ Parcel ID: 0, 3`0 -(7000 Zoning: Description of Work: Ey4eriorLznierter Qe,gL i -s Plan Review Contact Person: V-401" GO Title: Preside if - Phone: If a`t - 38 4- 87417 Fax: `fo`F- 381- 87gl E-mail: 'ert c OP gfreno✓c4, o rs. to w, Property Owner Information Name Ty'e_ u)t ls& , Co ►-n.Pa,n" `1 Street: 466 A104n FrAnWf irn sdrt d - City, State Zip: �an2eA FL 3 3 (po -3,. Phone: 10 7- 7 go - 0 75 `f Resident of property? : Contractor Information Name Gi F genoya-h'vem3nc. 1&-ic. Vriarlw Phone: `FO`f-- `f7`f,'f8o 8 Street: 1015 Ur►ion W11 til. !9"t'je- 7 Fax: `Fo `f - i'lf8- 'f'f4 0 City, State Zip: Alphare-HA, 6A 3000y' State License.No.: CG C 15;Z 1 7 70 Architect/Engineer Information ccc 13A7a80 Name: E Pz Street: 311 -A s woo cJ la n d Blvd City, St, Zip: Deland FL Bonding Company: U)esforn SurG_4A e0n2 fill Address: 5i'o u x FQII s S,,-" DaJc.- t-0. Building Permit ❑ Square Footage: No. of Dwelling Units: Electrical ❑ New Service - No. of AMPS: Phone: 384 - 73'f o 830 Fax: 3r?(,,- 7.31f - I? a a �_ E-mail: ee l G e p l e n c4 . n of J Mortgage Lender: ` Address: PERMIT INFORMATION Construction Type: Flood Zone: No. of Stories: Plumbing ❑ New Construction - No. of Fixtures: Mechanical 13 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. ,a1 Q3 11-3 Signature of Owner/Agent Date 44' �t t��iLSa AS A&&)r F)ti 4wc- i6 Date SUSAN F t MYCOMMMIo:a w EI�•,1010 EXPIRES Jr� • r�r ':t3, k018 Owner/Agent is Personally Known to Me pr Produced ID Type of 1D APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 UTILITIES: fafCia /0 /3 Signature of o tractor/Agent Date Er cc Fra r., Print Contr o /Agent's Name r A `� %' r ignaty e o o to o fiWAN F LOMORDO =� �'? MY COMMISSION It EE18DI63 EXPIRES January 28.2018 ,�' sionea .w" 998,Ofti9 Contractor/Agent isyPersonally Known to Me or Produced ID Type of ID WASTE WATER: BUILDING: ' City of Sanford O I Planning p and Development Services P8 -77 --Engineering — Floodplain Management Flood Zone Determination Request Form Name: , i ; oyr,f Firm: jer G ro•n c p Address: iU/s 64,�* City: r State: (VA Zip Code: 3 ooa �{ Phone: qbK-X171/- Y1178 Fax: Email: Property Address: 15,-00 V I J GM G c i' V Property Owner: So ^. Co NI'p 2=4 Parcel identification Number: ILA- ZQ -3 Q - 3(3 D - O 8 o O — O O a0 Phone Number: yd 7- 7,60- %SL Email: The reason for the flood plain determination is: ❑ New structure ❑ Existing Structure (pre -2007 FIRM adoption) Expansion/Addition ❑ Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4076) OFFICIAL USE ONLY Flood Zone:_ L Base Flood Elevation: Datum: -- FIRM Panel Number: 6 i Map Date: o The referenced Flood Insurance Rate Map indicates the following: ❑ The parcel is in the: ❑ floodplain ❑ floodway ❑ A portion of the parcel is in the: ❑ floodplain ❑ floodway The parcel is not in the: ❑-4eadplain ❑ floodway ❑ The structure is in the: ❑ floodplain ❑ floodway -The is not in the: oodplain ❑ floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: Reviewed by: f i. , sZ /// Date: 7- T:\Engr-Files\Elevation Certificate\Flood Zone Determination Request Form.doc �`' • n`.,�•.`yY�� '.�� (_ 11.E i.)1 C)c �.-"-',.���� "',��i (='ii"� 1 a•a!a E+�.c?��ac,n!r'.r.�,l� (ii�i�`.^�: Date: l LI$J3 _- - Pen rril It. Business or Project Narne- Address: _/�Oo_ �li ry C.�,r�' ,(�l✓.(_ _ .. _ Contact Name: Conlw-,t Plan Re; view Irifairo.atio,in K Co�istnac:�ic�n Fl (,A) 1.1 Fu's•: Alarm r7 Fi(ei Sprinkler f I I I!�iui I'I f2!t4c 17 f'�ittl BuUth Total Fee�;N www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1 1179 Description Qty Rate Total G&F Renovations would like to propose to do the following work. Entry Foyer Unit 8302 Clean floor 40.61 0.25 10.15 R Vinyl floor covering (sheet goods) - standard grade 40.61 0.50 20.31 Floor preparation for resilient flooring 40.61 0.00 R Carpet -metal transition strip 3 0.50 1.50 R&R Baseboard -31/4" 26.25 1.50 39.38 Paint baseboard -two coats 26.25 1.00 26.25 R&R 5/8" drywall' -hung, taped, ready for texture 210 2.00 420.00 Texture drywall -light hand texture 210 0.75 157.50 R&R 5/8" drywall '-hung, taped, ready for texture 40.61 2.00 81.22 R&R drywall -hung & fire taped only 40.61 2.00 81.22 Texture drywall -heavy hand texture 40.61 0.75 30.46 Paint the walls and ceiling -two coats 250.61 1.50 375.92 R&R Batt insulation -6" -R 19 -unfaced batt 28.67 6.00 172.02 R&R Blown insulation -10 depth -R26 40.61 4.00 162.44 R&R Exterior door -metal - insulated - flush or panel style 1 225.00 225.00 Steel door frame -3" opening 1 250.00 250.00 Door peep hole 1 0.00 Door knocker 1 0.00 Door lockset & deadbolt -exterior 1 25.00 25.00 Prime & paint door slab only -exterior (per side) 2 35.00 70.00 Paint door /window trim & jamb -2 coats (per side) 2 25.00 50.00 R&R Light fixture 1 25.00 25.00 R&R Switch 3 3.75 11.25 R&R Outlet 1 5.00 5.00 R&R Smoke detector 1 15.00 15.00 R&R Breaker panel 150 amp 1 0.00 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@agmail.com Page 1 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total Rewired -average residence -copper wiring 40.61 25.00 1,015.25 Entry Closet Clean floor 5.96 0.25 1.49 Carpet pad -Standard grade 5.96 0.00 Carpet -Standard grade 5.96 0.00 R&R Baseboard -3 1/4" 10.17 1.50 15.26 Paint baseboard -two coats 10.17 1.00 10.17 R&R 5/8" drywall -hung, taped, ready for texture 81.33 2.00 162.66 Texture drywall -light hand texture 81.33 0.75 61.00 R&R 5/8" drywall -hung, taped, ready for texture 5.96 2.00 11.92 R&R 5/8" drywall -hung & fire taped only 5.96 2.00 11.92 Texture drywall -heavy hand texture 5.96 0.75 4.47 Paint the walls and ceiling -two coats 87.29 1.50 130.94 R&R Batt insulation -6" -R 19 -unfaced batt 14.67 6.00 88.02 R&R Blown -in insulation -10" depth- R26 5.96 4.00 23.84 R&R Bifold door -full louvered - Single 1 0.00 R&R Shelving -wire (vinyl coated) 3 0.00 Rewire -average residence - copper wiring 5.96 25.00 149.00 Bedroom 1 Clean Floor 118.71 0.25 29.68 Carpet -Standard grade 118.71 0.50 59.36 Carpet pad -Standard grade 118.71 0.00 R&R Baseboard -3 1/4" 47.83 1.50 71.75 Paint baseboard -two coats 47.83 1.00 47.83 R&R drywall -hung, taped, ready for texture 382.67 2.00 765.34 Texture drywall -hung, taped, ready for texture 382.67 2.00 765.34 5/8" drywall -hung, taped, ready for texture 118.71 2.00 237.42 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 2 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total 5/8" drywall -hung & fire taped only 118.71 2.00 237.42 Texture drywall -heavy hand texture 118.71 0.75 89.03 Paint the walls and ceiling -two coats 501.38 1.50 752.07 R&R Batt insulation -6" -R 19 - unfaced batt 166 6.00 996.00 Blown -in insulation -10" depth -1126 118.71 4.00 474.84 R&R Interior door unit 1 65.00 65.00 Door knob -interior- Standard grade 1 15.00 15.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb -2 coats (per side) 2 5.00 10.00 Ceiling fan & light -Standard grade 1 1.50 1.50 R&R Switch 1 5.00 5.00 R&R Outlet 5 5.00 25.00 R&R Phone, TV, or speaker outlet 1 5.00 5.00 Smoke detector 1 15.00 15.00 Heat/AC register -Mechanically attached 1 12.00 12.00 R&R Aluminum window, single hung 13-19 sf 1 285.00 285.00 Sill -cultured marble on 2" x 4" wall 3 25.00 75.00 Window blind -aluminium-1" 14.1 to20 SF 1 12.50 12.50 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Rewire -average residence- copper wiring 118.71 20.00 2,374.20 Bedroom I Closet Clean floor 18.89 0.25 4.72 Carpet -Standard grade 18.89 0.00 Carpet pad -Standard grade 18.89 0.00 R&R Baseboard -3 1/4" 19 1.50 28.50 Paint baseboard -two coats 19 1.00 19.00 R&R 5/8" drywall -hung, taped, ready for texture 152 2.00 304.00 Texture drywall -light hand texture 152 0.75 114.00 R&R 5/8" drywall -hung, taped, ready for texture 18.89 2.00 37.78 R&R 5/8" drywall -hung & fire taped only 18.89 2.00 37.78 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 3 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1 1179 Description Qty Rate Total Texture drywall -heavy hand texture 18.89 0.75 14.17 Paint the walls and ceiling -two coats 170.89 1.50 256.34 R&R Batt insulation -6" -R19 -unfaced batt 22.67 6.00 136.02 R&R Blown -in insulation -10" depth- R26 18.89 4.00 75.56 R&R Bifold door -full louvered - Single 1 0.00 R&R Shelving -wire (vinyl coated) 19 0.00 R&R Light fixture 1 15.00 15.00 Rewire -average residence- copper wiring 18.89 25.00 472.25 Bathroom 1 R&R Vinyl floor covering (sheet goods) - Standard grade 42.71 0.25 10.68 Floor preparation for resilient flooring 42.71 0.00 0.00 R&R Baseboard' -3 1/4" 27.33 1.50 41.00 Paint baseboard -two coats 27.33 1.00 27.33 R&R 5/8" drywall -hung, taped, ready for texture 297.42 2.00 594.84 Texture drywall -light hand texture 221.17 0.75 165.88 R&R 5/8" drywall -hung, taped, ready for texture 55.63 2.00 111.26 R&R 5/8" drywall -hung & fire taped only 55.63 2.00 111.26 Texture drywall -heavy hand texture 55.63 0.75 41.72 Paint part of the walls and ceiling -two coats 276.79 1.50 415.19 R&R Batt insulation -6" -R 19 -unfaced batt 106.21 6.00 637.26 R&R Blow-in insulation - 10" depth - R26 55.63 4.00 222.52 R&R Interior door unit 1 225.00 225.00 Door knob -interior- Standard grade 1 15.00 15.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb -2 coats (per side) 2 5.00 10.00 R&R Light bar -4 lights 1 13.00 13.00 R&R Switch 1 5.00 5.00 R&R Outlet 1 5.00 5.00 R&R Heat/AC register -Mechanically attached 1 12.00 12.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 4 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total R&R Exhaust fan -Standard grade 1 25.00 25.00 R&R Exhaust vent duct -installed 1 45.00 45.00 Vanity 3 11.00 33.00 Counter top -flat laid plastic laminate -Standard grade 3 11.00 33.00 Backsplash -plastic laminate 5 11.00 55.00 Sink -single - Detach & reset 1 10.00 10.00 Sink faucet - Detach & reset 1 10.00 10.00 R&R P -trap assembly -ABS (plastic) 1 7.00 7.00 R&R Angle stop 2 5.00 10.00 Medicine cabinet -Detach & reset 1 5.00 5.00 Mirror -plate glass- Detach & reset 10.5 2.00 21.00 R&R Towel bar -Standard grade 1 10.00 10.00 R&R Toilet paper holder -Standard grade 1 10.00 10.00 R&R Shelving -wire (vinyl coated) 6.7 0.00 0.00 Toilet -Detach & reset 1 20.00 20.00 Clean Tub -Light 1 2.00 2.00 R&R Ceramic tile -Standard grade 50 3.00 150.00 R&R Towel Bar 1 10.00 10.00 R&R Soap dish -Wall mounted - Standard grade 1 10.00 10.00 Shower curtain rod -Detach & reset 1 5.00 5.00 Tub/Shower faucet -Detach & reset 1 25.00 25.00 Sprinkler head/escutcheon - Detach & reset 1 2.00 2.00 Rewire -average residence - copper wiring 55.63 20.00 1,112.60 kitchen Cathedral ceiling 127.9 1.00 127.90 Clean floor 127.9 0.25 31.98 R&R Vinyl floor covering (sheet goods) -Standard grade 127.9 0.00 0.00 Floor preparation for resilient flooring 127.9 0.00 0.00 R&R Baseboard -3 1/4" 41.67 1.50 62.51 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 5 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total Paint Baseboard - two coats 41.67 1.00 41.67 R&R 5/8" drywall -hung, taped, ready for texture 301.33 2.00 602.66 Texture drywall -light hand texture 301.33 0.75 226.00 R&R 5/8" drywall -hung, taped ready for texture 127.9 2.00 255.80 R&R drywall -hung & fire taped only 127.9 2.00 255.80 Texture drywall -heavy hand texture 127.9 0.75 95.93 Paint the walls and ceiling -two coats 429.24 1.50 643.86 R&R Batt insulation 6" - R 19 - unfaced batt 103.33 6.00 619.98 R&R Blown -in insulation -10" depth - R26 127.9 4.00 511.60 R&R Fluorescent -two tube- 4" fixture w/lens 1 22.00 22.00 R&R Light fixture 1 5.00 5.00 R&R Switch 1 5.00 5.00 R&R Outlet 2 5.00 10.00 R&R Ground fault interrupter (GFI) outlet 2 15.00 30.00 R&R Phone, TV, or speaker outlet 1 5.00 5.00 R&R Cabinetry -lower (base) units 6.5 25.00 162.50 R&R Cabinetry -upper (wall) units 10.5 25.00 262.50 R&R Counter top - flat laid plastic laminate- Standard grade 11 11.00 121.00 R&R Backsplash -plastic laminate 14.5 11.00 159.50 R&R Countertop -flat laid plastic laminate - Standard grade - Bar 10 11.00 110.00 top Sink -double- Detach & reset 1 10.00 10.00 Sink faucet -Detach & reset 1 5.00 5.00 R&R P Trap assembly - ABS (plastic) 1 10.00 10.00 R&R Angle Stop 1 5.00 5.00 Garbage disposer -Detach & reset 1 10.00 10.00 Dishwasher -Detach & reset 1 20.00 20.00 Range - gas- Remove & reset 1 10.00 10.00 Range hood -Detach & reset 1 5.00 5.00 Refrigerator -Remove & reset 1 10.00 10.00 R&R Countertop -flat laid plastic laminate - Desk Top 3 11.00 33.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 6 www.gfrenovations-com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description oty Rate Total R&R Backsplash -plastic laminate - Desk Top 7 11.00 77.00 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Rewire -averageresidence - copper wiring 127.9 20.00 2,558.00 Kitchen closet Clean floor 8.5 0.25 2.13 R&R Vinyl floor covering (sheet goods) -Standard grade 8.5 0.00 0.00 Floor preparation for resilient flooring 8.5 0.00 0.00 R&R Baseboard -3 1/4" 12.5 1.50 18.75 Paint baseboard - two coats 12.5 1.00 12.50 R&R 5/8" drywall -hung taped, ready for texture 100 2.00 200.00 Texture drywall -light hand texture 100 0.75 75.00 R&R 5/8" drywall -hung, taped ready for texture 8.5 2.00 17.00 R&R 5/8" drywall -hung &fire taped only 8.5 2.00 17.00 Texture drywall -heavy hand texture 8.5 0.75 6.38 Paint the walls and ceiling -two coats 108.5 1.50 162.75 R&R Blow-in insulation -10" depth - R26 8.5 4.00 34.00 R&R Bifold door -full louvered - Single 1 0.00 0.00 R&R Shelving -wire (vinyl coated) 15 0.00 0.00 Rewire -average residence - copper wiring 8.5 25.00 212.50 Living room Cathedral ceiling 158.67 1.00 158.67 Clean floor 158.67 0.25 39.67 Carpet -Standard grade 158.67 0.00 0.00 Carpet pad -Standard grade 158.67 0.00 0.00 R&R Carpet -metal transition strip 3 0.50 1.50 R&R Baseboard -3 1/4" 43.92 1.50 65.88 Paint Baseboard -two coats 43.92 1.00 43.92 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 7 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total R&R 5/8" drywall -hung, taped, ready for texture 322.75 2.00 645.50 Texture drywall -light hand texture 322.75 0.75 242.06 5/8" drywall -hung, taped ready for texture 158.67 2.00 317.34 5/8" drywall -hung & fire taped only 158.67 2.00 317.34 Texture drywall -heavy hand texture 158.67 0.75 119.00 Paint the walls and ceiling -two coats 481.42 1.50 722.13 R&R Batt insulation -6 R 19 -unfaced batt 90.67 6.00 544.02 Blown -in insulation -10" depth R-26 . 158.67 4.00 634.68 Ceiling fan without light -Standard grade 1 22.00 22.00 R&R Switch 2 5.00 10.00 R&R Outlet 6 5.00 30.00 R&R Phone, TV or speaker outlet 1 5.00 5.00 Smoke detector 1 15.00 15.00 R&R Heat/AC register -Mechanical attached 1 12.00 12.00 R&R Aluminum window, single hung 13-19 sf 2 285.00 570.00 R&R Sill -culture marble on 2" x 4" wall 6 25.00 150.00 R&R Window blind -aluminum - I" 20.1 to 32 SF 1 15.00 15.00 Sprinkler head/escutcheon -Detach & reset 1 2.00 2.00 Rewire -average residence- copper wiring 158.67 25.00 3,966.75 Hallway Clean floor 12.53 0.25 3.13 Carpet -Standard grade 12.53 0.00 0.00 Carpet pad - Standard grade 12.53 0.00 0.00 R&R Baseboard -3 1/4" 10.75 1.50 16.13 Paint baseboard - two coats 10.75 1.00 10.75 R&R 5/8" drywall -hung, taped, ready for texture 75.25 2.00 150.50 Texture drywall - light hand texture 75.25 0.75 56.44 R&R 5/8" drywall -hung, taped, ready for texture 12.53 2.00 25.06 R&R 5/8" drywall -hung & fire taped only 12.53 2.00 25.06 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivisionegmail.com Page 8 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total Texture drywall -heavy hand texture 12.53 0.75 9.40 Paint the walls and ceiling - two coats 87.78 1.50 131.67 R&R Blown -in insulation -10" depth -R26 12.53 4.00 50.12 R&R Switch 1 5.00 5.00 R&R Thermostat 1 15.00 15.00 Cold air return cover - Detach & reset 1 5.00 5.00 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Rewire - average residence - copper wiring 12.53 25.00 313.25 Seal truss system -up to 5/12 12.53 0.10 1.25 Laundry room Clean floor 9.17 0.25 2.29 R&R Vinyl floor covering (sheet goods) - Standard grade 9.17 0.00 0.00 Floor preparation for resilient flooring 9.17 0.00 0.00 R&R Baseboard -3 1/4" 12.17 1.50 18.26 Paint baseboard -two coats 12.17 1.00 12.17 R&R 5/8" drywall -hung, taped, ready for texture 85.17 2.00 170.34 Texture drywall -light hand texture 85.17 0.75 63.88 R&R 5/8" drywall -hung, taped, ready for texture 9.17 2.00 18.34 R&R 5/8" drywall -hung & fire taped only 9.17 2.00 18.34 Texture drywall -heavy hand texture 9.17 0.75 6.88 Paint the walls and ceiling -two coats 94.33 1.50 141.50 R&R Blown -in insulation -10" depth -R26 9.17 4.00 36.68 Bifold door -(2 slabs only) -Single- Detach & reset 1 5.00 5.00 R&R Clothes dryer vent - installed 1 10.00 10.00 Rewire -average residence - copper wiring 9.17 25.00 229.25 R&R 220 volt outlet 1 35.00 35.00 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 9.17 0.10 0.92 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 9 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total HVAC Closet Clean floor 9 0.25 2.25 R&R 5/8" drywall -hung, taped, ready for texture 96 2.00 192.00 R&R 5/8" drywall - hung, taped ready for texture 9 2.00 18.00 R&R 5/8" drywall -hung & fire taped only 9 2.00 18.00 Paint the walls and ceiling -two coats 105 1.50 157.50 R&R Blown -in insulation -10" depth -R26 9 4.00 36.00 R&R Air handler -with heat element -2 ton 1 800.00 800.00 R&R Central air -condenser unit - 2 ton -up to 13 SEER 1 800.00 800.00 R&R Ductwork -flexible - insulated - 8" round 40 10.00 400.00 Rewire - average residence - copper wiring 9 25.00 225.00 R&R 2" x 4" lumber -treated (.667 BF per LF) 12 4.00 48.00 Seal truss system -up to 5/12 9 0.10 0.90 Master Bedroom Clean floor 138.79 0.25 34.70 Carpet -Standard grade 138.79 0.00 0.00 Carpet pad - Standard grade 138.79 0.00 0.00 R&R Baseboard -3 1/4" 48.67 1.50 73.01 Paint baseboard -two coats 48.67 1.00 48.67 R&R 5/8" drywall -hung, taped, ready for texture 389.33 2.00 778.66 Texture drywall -light hand texture 389.33 0.75 292.00 R&R 5/8" drywall -hung, taped, ready for texture 138.79 2.00 277.58 R&R 5/8" drywall -hung & fire taped only 138.79 2.00 277.58 Texture drywall -heavy hand texture 138.79 0.75 104.09 Paint the walls and ceiling -two coats 528.13 1.50 792.20 R&R Batt insulation -6" - R19 - unfaced batt 194.67 6.00 1,168.02 R&R Blown -in insulation -10" depth R-26 138.79 4.00 555.16 R&R Interior door unit 1 20.00 20.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 10 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total Door Knob -interior - Standard grade 1 15.00 15.00 Paint door slab only -2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb -2 coats (per side) 2 10.00 20.00 R&R Ceiling fan & light - Standard grade 1 20.00 20.00 R&R Switch 1 5.00 5.00 R&R Outlet 5 5.00 25.00 R&R Phone, TV, or speaker outlet 2 5.00 10.00 R&R Smoke detector 1 15.00 15.00 R&R Heat/AC register - Mechanically attached 1 12.00 12.00 Window screen, I - 9 SF 1 10.00 10.00 R&R Sill -cultured marble on 2" x 4" wall 3 25.00 75.00 Window blind - aluminum - 1" -14.1 to 20 SF 1 15.00 15.00 Sprinkler head/escutcheon - Detach adn reset 1 2.00 2.00 Rewire -average residence - copper wiring 138.79 25.00 3,469.75 Seal truss system -up to 5/12 138.79 0.10 13.88 Master Closet Clean floor 6 0.25 1.50 Carpet -Standard grade 6 0.00 0.00 Carpet pad - Standard grade 6 0.00 0.00 R&R Baseboard - 3 1/4" 10 1.50 15.00 Paint baseboard -two coats 10 1.00 10.00 R&R 5/8" drywall -hung, taped, ready for texture 80 2.00 160.00 Texture drywall -light hand texture 80 2.00 160.00 R&R 5/8" drywall -hung, taped, ready for texture 6 2.00 12.00 R&R 5/8" drywall -hung & fire taped only 6 2.00 12.00 Texture drywall -heavy hand texture 6 0.75 4.50 Paint the walls and ceiling -two coats 86 1.50 129.00 R&R Blown -in insulation -10" depth - R26 6 4.00 24.00 R&R Bifold door - full louvered - Single 1 0.00 0.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 11 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 . Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total Shelving -wire (vinyl coated) Detach & reset 15 0.00 0.00 Rewire -average residence- copper wiring 6 25.00 150.00 Seal truss system -up to 5/12 6 0.10 0.60 HWH Closet Clean floor 8.33 0.25 2.08 R&R 5/8"drywall -hung, taped, ready for texture 93.33 2.00 186.66 Texture drywall -light hand texture 93.33 0.75 70.00 R&R 5/8" drywall -hung taped, ready for texture 8.33 2.00 16.66 R&R 5/8" drywall -hung & fire taped only 8.33 2.00 16.66 Texture drywall -heavy hand texture 8.33 0.75 6.25 Paint the walls and ceiling -two coats 101.67 1.50 152.51 R&R Batt insulation -6" -R 19 - unfaced batt 26.67 6.00 160.02 R&R Blown -in insulation -10 depth - R26 8.33 4.00 33.32 Bifold door (2 slabs only) - Single - Detach& reset 1 5.00 5.00 Water heater - Detach & reset 1 20.00 20.00 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Rewire - average residence - copper'wiring 8.33 25.00 208.25 Seal truss system -up to 5/12 8.33 0.10 0.83 Opens in Master Bath Clean floor 67.56 0.25 16.89 R&R B Vinyl floor covering (sheet goods) - Standard grade 53.81 0.00 0.00 Floor preparation for resilient flooring 53.81 0.00 0.00 R&R Carpet -metal transition strip 3 0.50 1.50 R&R Baseboard -3 1/4" 28.17 1.50 42.26 Paint baseboard -two coats 28.17 1.00 28.17 R&R 5/8" drywall -hung, taped, ready for texture 303.83 2.00 607.66 Texture drywall -light hand texture 230.33 0.75 172.75 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 12 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total R&R 5/8" drywall -hung, taped, ready for texture 67.56 2.00 135.12 R&R 5/8" drywall -hung & fire taped only 67.56 2.00 135.12 Texture drywall -heavy hand texture 67.56 0.75 50.67 Paint part of the walls and ceiling - two coats 297.9 1.50 446.85 R&R Batt insulation -6" - R 19 -unfaced batt 72 6.00 432.00 R&R Blown -in insulation -10" depth - R26 67.56 4.00 270.24 R&R Interior door unit 1 20.00 20.00 Door knob -interior - Standard grade 1 15.00 15.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb - 2 coats (per side) 2 10.00 20.00 R&R Light bar - 4 lights 1 13.00 13.00 R&R Switch 2 5.00 10.00 R&R Outlet 1 5.00 5.00 R&R Head/AC register - Mechanically attached 1 12.00 12.00 R&R Exhaust fan -Standard grade 1 25.00 25.00 R&R Exhaust vent duct - installed 1 45.00 45.00 R&R Vanity 3 25.00 75.00 R&R Countertop -flat laid plastic laminate - Standard grade 6 11.00 66.00 R&R Backsplash -plastic laminate 8 11.00 88.00 Sink -single- Detach & reset 1 10.00 10.00 Sink faucet - Detach & reset 1 10.00 10.00 R&R P -trap assembly - ABS (plastic) 1 5.00 5.00 R&R Angle stop 2 5.00 10.00 Medicine cabinet - Detach & reset 1 5.00 5.00 Mirror -plate glass - Detach & reset 21 5.00 105.00 R&R Towel bar - Standard grade 1 10.00 10.00 R&R Toilet paper holder - Standard grade 1 10.00 10.00 Toilet - Detach & reset 1 15.00 15.00 Clean Tub - Light 1 1.00 1.00 Clean ceramic tile 50 0.50 25.00 Clean towel bar 1 0.50 0.50 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.ildivision@gmail.com Page 13 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total Clean soap dish 1 0.50 0.50 Shower curtain rod - Detach and reset 1 5.00 5.00 Clean tub/shower faucet - Light 1 10.00 10.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Rewire - average residence - copper wiring 67.56 25.00 1,689.00 Seal truss system - up to 5/12 67.56 0.10 6.76 Master Walk In Closet Clean Floor 37.5 0.25 9.38 Carpet - Standard grade 37.5 0.00 0.00 Carpet pad - Standard grade 37.5 0.00 0.00 R&R Baseboard -3 1/4" 25 1.50 37.50 Paint baseboard -two coats 25 1.00 25.00 R&R 5/8"n drywall -hung, taped, ready for texture 200 2.00 400.00 Texture drywall -light hand texture 200 0.75 150.00 R&R 5/8" drywall -hung, taped ready for texture 37.5 2.00 75.00 R&R 5/8" drywall -hung *& fire taped only 37.5 2.00 75.00 Texture drywall and ceiling -two coats 37.5 0.75 28.13 Paint the walls and ceiling -two coats 237.5 1.50 356.25 R&R Batt insulation - 6" - R 19 - unfaced batt 100 6.00 600.00 R&R Blown -in insulation -10" depth- R26 37.5 4.00 150.00 R&R Bifold door -full louvered- Single 1 0.00 0.00 Shelving -wire (vinyl coated) - Detach & reset 25 0.00 0.00 R&R Light fixture 1 15.00 15.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Rewire -average residence - copper wiring 37.5 25.00 937.50 Seal truss system -up to 5/12 37.5 0.10 3.75 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 14 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1179 Description Qty Rate Total All labor and material is included All Permitting and Engineering is included. Total $55,265.06 Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 15 Savannah Electric Inc City of Sanford 699 Eldron Ct Deltona, FI 32738 407-346-8551 To Whom It May Concern, The following location has been inspected and tested by a state of Florida licensed electrical contractor. The following units are safe and ready for the power meters to be installed. Wyndham apartments 1500 Wyndham Crest Boulevard, Sanford FI Electrical permit # 14-433 Building 8 unit 3031--- A0 Building 8 unit 304-'-P'e- 12-00f Building 8 unit 301— Ido Please call Duke Energy at your earliest convenience for authorization to reinstall power meters. Feel free to call me with any questions or concerns. Joseph Clodfelter 407 925 3056 Owner Savannah Electric State Licensed #ER13014657 PERMIT # 14 —L43 3 DEC 201CITY OF SANFORD BUILDINGWEIRE_P—REVEN— ION DIVISION EARLY START AUTHORIZATION — APPLICATION/ PERMIT Project Name: V h W ?1,6A C Date: 10 f' a0!3 Project Address: 1500,J W !(#i d h Q Pn Place ce Uf U d .SGt n4;rd 3 a 7 73 Contractor Name: G F Re h o V0--%0 h S -Tn c• /Eri*r- F I—Q h co EARLY START AUTHORIZATION CONDITIONS City of Sanford and the Owner/contractor listed agree to the following: I . A complete building permit application and plans shall be submitted at the time of the request for Early Start Authorization. 2. This Early Start Authorization is for interior work or other work as determined by the Building Official. 3. Work must comply with any and all other local, state and federal agencies related to the development and construction proposed and compliance with asbestos NESHAP regulations must occur for all demolition work. 4. Work shall not be concealed and must remain open for all necessary inspections. At the time of inspections, any work concealed shall be uncovered. 5. The contractor acknowledges that all subcontractors will be properly licensed and have current worker's compensation coverage. 6. All subcontractors are responsible for pulling their own permits. 7. Inspections of work for any construction trade will not be made until a permit has been issued for the trade. 8. The Early Start Authorization does not guarantee that construction plans will be approved as submitted. All work done prior to the issuance of the required permits shall be at the Owner's/Contractors risk. 9. The Owner/Contractor acknowledge that additional fees, including but not limited to impact and zoning fees, may be due at the time of building permit issuance, and or prior to Certificate of Occupancy. 10. The Owner/Contractor acknowledge that additional site improvements, including but not limited to installation of a grease trap, accessible parking and landscaping, may be required'at the time of building permit issuance. 11. The Owner/Contractor agree to indemnify and hold the City of Sanford/Agents free and harmless from any and all claims, causes of action, damages, losses penalties or costs, including but not limited to, all attorneys fees (whether from litigation or administrative proceeding, including cost and fees on appeal), with respect to any person or government authority arising out of, either directly or indirectly, the construction or operation at the premises covered by the Early Start Authorization, whether the liability, loss or damage is caused by, or arises out of, the negligence or the City of Sanford/Agents or its officers, agents, employees, or otherwise. 12. If the City of Sanford/Agents shall be subject to any claim, demand or penalty or become a party to any suit or other judicial or administrative proceeding by reason of any claimed act or omission by any party, or by reason of any act occurring on the subject premises, or by reason of any omission with respect to the construction or operation on the subject premises, the Owner/contractor shall indemnify and hold City of Sanford/Agents harmless against all judgments, settlements, penalties and expenses, including attorney's fees, court costs and other expense of litigation of defense relating to such claim or litigation or administrative proceeding, at the election of the City of Sanford/Agents, the Owner/Contractor shall also defend the City of Sanford. 13. It is understood and hereby acknowledged between the parties hereto that the City of Sanford/Agents shall not be liable for any act or other obligation to the Owner/Contractor. 14. This Early Start Authorization will terminate upon the issuance of a Building Permit for property covered under this Early Start Authorization; however, this agreement shall remain in effect for all events occurring prior to the issuance of the Building Permit. By signing this Early Start Authorization Application, the undersigned acknowledges and agrees to condition 1 through 14. ntractor Signature Owner Signature c. �G Date 7gl Name:; t1' t'vi Address: U ' —— 7 �Lp NQ d OCE OF COPAIMl'aHICEAflEfIff State o'r Florida County of S?mino)la� t 1 Permit Plumber: I 1 — l 3-�S Parcel ID Numbar MARYANNE MORSE, SEMINOLE COUNTY CLERK OF CIRCUIT COURT III COMPTROLLER AK 08171 Pg 0441; (Ipg) CLERK'S 1t 2013150932 RECORDED 12/03/2013 09:25;21 AM RECORDING FEES 10.00 l y.a " Rl di tl:iy -Id '�4�n c000 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713. Florida Statutes, the following Information is provided in this Notice of Commencement OF PROPERTY: DESCRIPTION OF IM address if available) OIP PIED IN RPAATION: r Name— W I / JIY)' ___Jig✓�� Address Fee Simple Title Holder (if other than owner) Name:_ Address Name Address. lUIJ- - L,( t)JO» jYY I I KL d -r 7 WrfQbdil fJ&a,_ Gy- W -✓��ti7 Persons within the Staie of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name - In addition to himself, Owner Designates Section 713 13(I)(b), Florida Statutes of To receive a copy of the Llenor's Notice as Provided in Expiration Date of Notice o'r Commencement (The a piralion date is 1 year fi•orn date of recording unless a different data is specified) WARNING TO OWNER ANY PAYMENTS MADE BYTHEOWNER AFTER THE EXPIRATIOPI OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713 13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR API ATTORNEY BEFORE COMMENCING WORT( OR RECORDING YOUR NOTICE OF COMMENCEMENT lhideT panafties of perjury, i declare that I have read the foregoing and that Zhe facts stated in it are trtia to the !Desi o; my %nowleclge and belief. wne s Signature �L t.} owner's Printed Name Ronda Statute 713 130 I(g) ' The owner must sign the notice of commencement and no one else may be pemntttid to sign in his of her stead' State of i el r., County of _ / _6J I � 11 The foregoing insiru+neni rias a a;nosledged before me this day of r J /� � by .—�� ._`S.L� I. S(n.1 --- _—_. _ ----- iNtio Is par.-nnalfy I:no vn to ria ❑ Name of person making statemepf� OR Who has prorlticed idana7icat,r.)n [9'tyoe of ideridiicallon oroduced•.. A- Y/4e-= --_— -- }TME lIKIPPIEDCOPY-MARY EMORSE CLERK OF THE CIRCUIT OUR ND__ R� COMPTROLLER n �rarv. ire susAN F LOMWA SEMINOLE C LINTY, F RIDA rr/I'o'"cu11I� MY COMMGSION 11t EEIGO103 BY DEPUTY C1ERK o 6 C 0 a 2013 . • EXPIRE8 JI'tnuery 28r 2014 0 . ,�� FbAeaN .eeT l www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total G&F Renovations would like to propose to do the following work. Unit 8301 Entry /Foyer Clean floor 40.61 0.25 10.15 R&R Vinyl floor covering (sheets goods) - Standard grade 40.61 0.50 20.31 Floor preparation for resilient flooring 40.61 0.00 0.00 R&R Carpet -metal transition strip 3 0.50 1.50 Baseboard- 3 1/4" 26.25 1.50 39.38 Paint baseboard - two coats 26.25 1.00 26.25 Drywal I replacement per LF -up to 2" tall 26.25 0.00 0.00 Texture drywall -light hand texture 210 0.75 157.50 R&R 5/8" drywall -hung, taped, ready for texture 40.61 2.00 81.22 R&R 5/8" drywall - hung & fire taped only 40.61 2.00 81.22 Texture drywall -heavy hand texture 40.61 0.75 30.46 Paint the walls and ceiling - two coats 250.61 1.50 375.92 R&R Batt insulation -6" - rl9 unlaced batt 7.17 6.00 43.02 R&R Blown -in insulation -10" depth - R26 40.61 4.00 162.44 R&R Exterior door -metal - insulated - flush or panel style 1 225.00 225.00 R&R Steel door frame -3" opening 1 250.00 250.00 Door peep hole 1 0.00 0.00 Door knocker 1 0.00 0.00 Door lockset & deadbolt- exterior 1 25.00 25.00 Prime & paint door slab only -exterior (per side) 1 35.00 35.00 Paint door/window trim & jamb -2 coats (per side) 2 10.00 20.00 R&R Light fixture 2 5.00 10.00 Sprinkler head/escutcheon- Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 40.61 0.10 4.06 Electrician -per hour 8 0.00 0.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 1 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total 0.00 0.00 Entry Closet Clean Floor 5.96 0.25 1.49 Carpet pad - Standard grade 5.96 0.00 0.00 Carpet - Standard grade 5.96 0.00 0.00 R&R Baseboard -3 1/4" 10.17 1.50 15.26 Paint baseboard -two coats 10.17 1.00 10.17 Drywall replacement per LF -up to 2" tall 10.17 0.00 0.00 Texture drywall -light hand texture 81.33 0.75 61.00 R&R 5/8" drywall -hung, taped, ready for texture 5.96 2.00 11.92 R&R 5/8" drywall -hung & fire taped only 5.96 2.00 11.92 Texture drywall -heavy hand texture 5.96 0.75 4.47 Paint the walls and ceiling -two coats 87.29 1.50 130.94 R&R Batt insulation -6" - R19 - unfaced batt 3.67 6.00 22.02 R&R Blown -in insulation - 10" depth - R26 5.96 4.00 23.84 Bifold door -(2 slabs only) -Single - Detach & reset 1 0.00 0.00 Shelving -wire (vinyl coated) - Detach & reset 3 0.00 0.00 Seal truss system -up to 5/12 5.96 0.10 0.60 Bedroom 1 Clean floor 118.71 0.25 29.68 Carpet -Standard grade 118.71 0.00 0.00 Carpet pad -Standard grade 118.71 0.00 0.00 R&R Baseboard 3 1/4" 47.83 1.50 71.75 Paint baseboard -two coats 47.83 1.00 47.83 Drywall replacement per LF -up to T tall 47.83 0.00 0.00 Texture drywall -light hand texture 382.67 0.75 287.00 R&R 5/8" drywall -hung, taped, ready for texture 118.71 2.00 237.42 R&R 5/8" drywall hung & fire taped only 118.71 2.00 237.42 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivisionegmail.com Page 2 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Texture drywall - heavy hand texture 118.71 0.75 89.03 Paint the walls and ceiling -two coats 501.38 1.50 752.07 R&R Batt insulation - 6" - R 19 -unfaced batt 41.5 6.00 249.00 R&R Blown -in insulation -10" depth - R26 118.71 4.00 474.84 R&R Interior door unit 1 225.00 225.00 Door lockset - Detach & reset 1 0.00 0.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb - 2 coats (per side) 2 10.00 20.00 Ceiling fan -Detach & reset 1 0.00 0.00 R&R Smoke detector 1 15.00 15.00 Heat/AC register - Mechanically attached - Detach & reset 1 12.00 12.00 Window blind -horizontal or vertical - Detach & reset 1 0.00 0.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 118.71 0.10 11.87 Bedroom Closet Clean floor 18.89 0.25 4.72 Carpet -Standard grade 18.89 0.00 0.00 Carpet pad - Standard grade 18.89 0.00 0.00 R&R Baseboard -3 1/4" 19 1.50 28.50 Paint baseboard - two coats 19 1.00 19.00 Drywall replacement per LF -up to 2" tall 19 0.00 0.00 Texture drywall - light hand texture 152 0.75 114.00 R&R 5/8" drywall -hung, taped ready for texture 18.89 2.00 37.78 R&R 5/8" drywall - hung & fire taped only 18.89 2.00 37.78 Texture drywall -heavy hand texture 18.89 0.75 14.17 Paint the walls and ceiling -two coats 170.89 1.50 256.34 R&R Batt insulation - 6" - R 19 - unfaced batt 5.67 6.00 34.02 R&R Blown -in insulation -10 " depth - R26 18.89 4.00 75.56 Bifold door - (2 slabs only) - Single - Detach & reset 1 0.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivisionCgmail.com Page 3 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Shelving -wire (vinyl coated) - Detach & reset 19 0.00 0.00 R&R -wire (vinyl coated) - Detach & reset 1 0.00 0.00 Seal truss system -up to 5/12 18.89 0.10 1.89 Opens in Bathroom Clean floor 30.83 0.25 7.71 R&R Vinyl floor covering (sheet goods) - Standard grade 42.71 0.50 21.36 Floor preparation for resilient flooring 42.71 0.00 0.00 R&R Baseboard - 3 1/4" 27.33 1.50 41.00 Paint baseboard - two coats 27.33 1.00 27.33 Drywall replacement per LF -up to 2" tall 27.33 0.00 0.00 Texture drywall -light hand texture 221.17 0.75 165.88 R&R 5/8" drywall - hung, taped, ready for texture 55.63 2.00 111.26 R&R 5/8" drywall - hung & fire taped only 55.63 2.00 111.26 Texture drywall -heavy hand texture 55.63 0.75 41.72 Paint part of the walls and ceiling - two coats 276.79 1.50 415.19 R&R Blown -in insulation -10" depth - R26 55.63 4.00 222.52 R&R Interior door unit 1 225.00 225.00 Door lockset - Detach & reset 1 25.00 25.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb - 2 coats (per side) 2 5.00 10.00 R&R Light bar - 4 lights 1 13.00 13.00 Heat/AC register - Mechanically attached - Detach & reset 1 12.00 12.00 Exhaust fan - Detach & reset 1 25.00 25.00 R&R Exhaust vent duct - installed 1 45.00 45.00 R&R Vanity 3 11.00 33.00 R&R Countertop - flat laid plastic laminate - Standard grade 3 11.00 33.00 R&R Backsplash - plastic laminate 5 11.00 55.00 Sink - single - Detach & reset 1 10.00 10.00 Sink faucet - Detach & reset 1 10.00 10.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 4 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total R&R P -trap assembly - ABS (plastic) 1 7.00 7.00 R&R Angle stop 2 5.00 10.00 Medicine cabinet - Detach & reset 1 5.00 5.00 Mirror -plate glass - Detach & reset 10.5 2.00 21.00 Towel bar - Detach & reset 1 10.00 10.00 Toilet paper holder -Detach & reset 1 10.00 10.00 Shelving -wire (vinyl coated) - Detach & reset 6.7 0.00 0.00 Toilet - Detach & reset 1 0.00 0.00 Shower curtain rod - Detach & reset 1 0.00 0.00 Sprinkler head/escutcheon - Detach adn reset 1 2.00 2.00 Seal truss system -up to 5/12 55.63 0.10 5.56 Kitchen Opens into Kitchen Cathedral ceiling 0.00 0.00 Clean floor 127.9 0.25 31.98 R&R Vinyl Floor covering (sheet goods) - Standard grade 127.9 0.50 63.95 Floor preparation for resilient flooring 127.9 0.00 0.00 R&R Baseboard -two coats 41.67 1.50 62.51 Paint baseboard -two coats 41.67 1.00 41.67 Drywall replacement per LF -up to T tall 41.67 0.00 0.00 Texture drywall - light hand texture 301.33 0.75 226.00 R&R 5/8" drywall -hung, taped, ready for texture 127.9 2.00 255.80 R&R 5/8" drywall -hung & fire taped only 127.9 2.00 255.80 Texture drywall -heavy hand texture 127.9 0.75 95.93 Paint the walls and ceiling - two coats 429.24 1.50 643.86 R&R Blown -in insulation -10" depth - R26 127.9 4.00 511.60 R&R Fluorescent -two tube - 4'- fixture w/lens 1 0.00 0.00 R&R Light fixture 1 5.00 5.00 R&R Cabinetry -lower (base) units 6.5 25.00 162.50 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 5 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total R&R Cabinetry - upper (wall) units 10.5 25.00 262.50 ' R&R Countertop -flat laid laminate - Standard grade 11 11.00 121.00 R&R Backsplash -plastic laminate 14.5 11.00 159.50 R&R Countertop -flat laid plastic laminate - Standard grade - Bar 10 11.00 110.00 top Sink - double - Detach & reset 1 10.00 10.00 Sink faucet - Detach & reset 1 10.00 10.00 R&R P -trap assembly -ABS (plastic) 1 7.00 7.00 Angle stop 1 5.00 5.00 Garbage disposer - Detach & reset 1 5.00 5.00 Dishwasher - Detach & reset 1 10.00 10.00 Range - gas - Remove & reset 1 10.00 10.00 Range hood - Detach & reset 1 5.00 5.00 Refrigerator - Remove & reset 1 5.00 5.00 R&R Countertop - flat laid plastic laminate - Desk Top 3 11.00 33.00 R&R Backsplash - plastic laminate - Desk Top 7 11.00 77.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 127.9 0.10 12.79 Kitchen Closet Clean floor 8.5 0.25 2.13 R&R Vinyl floor covering (sheet goods) - Standard grade 8.5 0.50 4.25 Floor preparation for resilient flooring 8.5 0.00 0.00 R&R Baseboard -3 1/4" 12.5 1.50 18.75 Paint baseboard - two coats 12.5 1.00 12.50 Drywall replacement per LF -up to T tall 12.5 0.50 6.25 Texture drywall - light hand texture 100 0.75 75.00 R&R 5/8" drywall -hung, taped, ready for texture 8.5 2.00 17.00 R&R 5/8" drywall -hung & fire taped only 8.5 2.00 17.00 Texture drywall - heavy hand texture 8.5 0.75 6.38 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 6 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description oty Rate Total Kitchen closet Paint the walls and ceiling -two coats 108.5 1.50 162.75 R&R Blown -in insulation -10" depth - R26 8.5 4.00 34.00 . Bifold door - (2 slabs only) - Single - Detach & reset 1 0.00 0.00 Shelving -wire (vinyl coated) -Detach & reset 15 0.00 0.00 Seal truss system -up to 5/12 8.5 0.10 0.85 Living Room Cathedral ceiling 0.00 0.00 Clean floor 158.67 0.25 39.67 Carpet - Standard grade 158.67 0.00 0.00 Carpet pad - Standard grade 158.67 0.00 0.00 R&R Carpet -metal transition strip 3 0.50 1.50 R&R Baseboard -3 1/4" 43.92 1.50 65.88 Paint baseboard -two coats 43.92 1.00 43.92 Drywall replacement per LF -up to T tall 43.92 0.00 0.00 Texture drywall -light hand texture 322.75 0.75 242.06 R&R 5/8" drywall - hung, taped, ready for texture 158.67 2.00 317.34 R&R 5/8" drywall - hung & fire taped only 158.67 2.00 317.34 Texture drywall -heavy hand texture 158.67 0.75 119.00 Paint the walls and ceiling - two coats 481.42 1.50 722.13 R&R Batt insulation -6" - R19 unfaced batt 22.67 6.00 136.02 R&R Blown -in insulation -10" depth - R26 158.67 4.00 634.68 Ceiling fan - Detach & reset 1 0.00 0.00 R&R Smoke detector 1 15.00 15.00 Heat/AC register - Mechanically attached - Detach & reset 1 12.00 12.00 Window blind -horizontal or vertical - Detach & reset 1 0.00 0.00 Sprinkler head/escutcheon -Detach and reset 1 2.00 2.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 7 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Seal truss system -up to 5/12 158.67 0.10 15.87 Hallway Clean floor 12.53 0.25 3.13 Carpet -Standard grade 12.53 0.00 0.00 Carpet pad - Standard grade 12.53 0.00 0.00 R&R Baseboard - 31/4" 12.53 1.50 18.80 Paint baseboard - two coats 10.75 1.00 10.75 Drywall replacement per LF -up to T tall 10.75 0.50 5.38 Texture drywall -light hand texture 75.25 0.75 56.44 R&R 5/8" drywall -hung, taped, ready for texture 12.53 2.00 25.06 R&R 5/8" drywall - hung & fire taped only 12.53 2.00 25.06 Texture drywall heavy hand texture 12.53 0.75 9.40 Paint the walls and ceiling - two coats 87.78 1.50 131.67 R&R Blown -in insulation -10" depth - R26 12.53 4.00 50.12 Cold air return cover -Detach and reset 1 0.00 0.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 12.53 0.10 1.25 Laundry Room. R&R Vinyl Floor covering (sheet goods) - Standard grade 9.17 0.50 4.59 Floor preparation for resilient flooring 9.17 0.00 0.00 R&R Baseboard -3 1/4" 12.17 1.50 18.26 Paint baseboard -two coats 12.17 1.00 12.17 Drywall replacement per LF -up to T tall 12.17 0.00 0.00 Texture drywall -light hand texture 85.17 0.75 63.88 R&R 5/8" drywall -hung, taped, ready, for texture 9.17 2.00 18.34 R&R 5/8" drywall - hung & fire taped only 9.17 2.00 18.34 Texture drywall -heavy hand texture 9.17 0.75 6.88 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gmail.com gfreno.fldivision@gmail.com Page 8 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Paint the walls and ceiling -two coats 94.33 1.50 141.50 R&R Blown -in insulation - 10" depth - R26 9.17 4.00 36.68 Bifold door -(2 slabs only) -Single - Detach & reset 1 0.00 0.00 R&R Clothes dryer vet -installed 1 10.00 10.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 9.17 0.10 0.92 HVAC Closet Drywall replacement per LF -up to T tall 12 0.00 0.00 R&R 5/8" drywall -hung, taped, ready for texture 9 2.00 18.00 R&R 5/8" drywall -hung & fire taped only 9 2.00 18.00 Paint the walls and ceiling - two coats 105 1.50 157.50 R&R Blown -in insulation -10" depth - R26 9 4.00 36.00 Seal truss system -up to 5/12 9 0.10 0.90 0.00 Master Bedroom Clean floor 138.79 0.25 34.70 Carpet -Standard grade 138.79 0.00 0.00 Carpet pad - Standard grade 138.79 0.00 0.00 R&R Baseboard -3 1/4" 48.67 1.50 73.01 Paint baseboard -two coats 48.67 1.00 48.67 Drywall replacement per LF -up to T tall 48.67 0.00 0.00 Texture drywall - light hand texture 389.33 0.75 292.00 R&R 5/8" drywall -hung taped, ready for texture 138.79 2.00 277.58 R&R 5/8" drywall -hung & fire taped only 138.79 2.00 277.58 Texture drywall -heavy hand texture 138.79 0.75 104.09 Paint the walls and ceiling - two coats 528.13 1.50 792.20 R&R Batt insulation -6" - R 19 - unfaced batt 48.67 6.00 292.02 R&R Blown -in insulation -10" depth - R26 138.79 4.00 555.16 R&R Interior door unit 1 0.00 0.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 9 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Door lockset - Detach & reset 1 0.00 0.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 Paint door/window trim & jamb - 2 coats (per side0 2 5.00 10.00 R&R Ceiling fan & light - Standard grade 1 1.50 1.50 R&R Smoke detector 1 15.00 15.00 Heat/Ac register -Mechanically attached - Detach & reset 1 12.00 12.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 138.79 0.10 13.88 Master Closet I Clean floor 6 0.25 1.50 Carpet - Standard grade 6 0.00 0.00 Carpet pad - Standard grade 6 0.00 0.00 R&R Baseboard - 3 1/4" 10 1.50 15.00 Paint baseboard -two coats 10 1.00 10.00 Drywall replacement per LF -up to T tall 10 0.00 0.00 Texture drywall -light hand texture 80 0.75 60.00 R&R 5/8" drywall - hung, taped, ready for texture 6 2.00 12.00 R&R 5/8" drywall - hung & fire taped only 6 2.00 12.00 Texture drywall - heavy hand texture 6 0.75 4.50 Paint the walls and ceiling - two coats 86 1.50 129.00 R&R Blown -in insulation -10" depth - R26 6 4.00 24.00 Bifold door - (2 slabs only) - Single - Detach & reset 1 0.00 0.00 Shelving -wire (vinyl coated) - Detach & reset 15 0.00 0.00 Seal truss system -up to 5/12 6 0.10 0.60 HWH Closet Clean floor 8.33 0.25 2.08 Drywall replacement per LF -up to T tall 11.67 0.00 0.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 10 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Texture drywall -light hand texture 93.33 0.75 70.00 R&R 5/8" drywall -hung, taped, ready for texture 8.33 2.00 16.66 R&R 5/8" drywall -hung & fire taped only 8.33 2.00 16.66 Texture drywall -heavy hand texture 8.33 0.75 6.25 Paint the walls and ceiling - two coats 101.67 1.50 152.51 R&R Batt insulation - 6" - R19 - unfaced batt 6.67 6.00 40.02 R&R Batt insulation -10" depth - R26 8.33 4.00 33.32 Bifold door - (2 slabs only) - Single -Detach & reset 1 0.00 0.00 Water heater -Detach & reset 1 0.00 0.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 8.33 0.10 0.83 Opens into Master Bath Clean floor 67.56 0.25 16.89 R&R Vinyl floor covering (sheet goods) - Standard grade 53.81 0.50 26.91 Floor preparation for resilient flooring 53.81 0.00 0.00 R&R Carpet - metal transition strip 3 0.50 1.50 R&R Baseboard 3 1/4" 28.17 1.50 42.26 Paint baseboard -two coats 28.17 1.00 28.17 Drywall replacement per LF -up to T tall 28.17 0.00 0.00 Texture drywall -light hand texture 230.33 0.75 172.75 R&R 5/8" drywall - hung, taped, ready for texture 67.56 2.00 135.12 R&R 5/8" drywall - hung & fire taped only 67.56 2.00 135.12 Texture drywall -heavy hand texture 67.56 0.75 50.67 Paint part of the walls and ceiling - two coats 297.9 1.50 446.85 R&R Blown -in insulation -10" depth - R26 67.56 4.00 270.24 R&R Interior door unit 1 225.00 225.00 Door lockset -Detach & reset 1 25.00 25.00 Paint door slab only - 2 coats (per side) 2 10.00 20.00 R&R Light bar - 4 lights 2 13.00 26.00 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivisiont✓gmail.com Page 11 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC l 327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description oty Rate Total Heat/AC register - Mechanically attached - Detach & reset 1 12.00 12.00 Exhaust fan - Detach & reset 1 25.00 25.00 R&R Exhaust vent duct -installed 1 45.00 45.00 R&R Vanity 3 0.00 0.00 R&R Countertop -flat laid plastic laminate -Standard grade 6 11.00 66.00 R&R Backsplash -plastic laminate 8 11.00 88.00 Sink - single - Detach & reset 1 10.00 10.00 Sink faucet - Detach & reset 1 10.00 10.00 R&R P -trap assembly - ABS (plastic) 1 7.00 7.00 R&R Angle stop 2 5.00 10.00 Medicine cabinet - Detach & reset 1 5.00 5.00 Mirror -plate glass - Detach & reset 21 2.00 42.00 Towel bar - Detach & reset 1 10.00 10.00 Toilet paper holder - Detach & reset 1 10.00 10.00 Toilet - Detach & reset 1 20.00 20.00 Shower curtain rod - Detach & reset 1 0.00 0.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 67.56 2.00 135.12 Master Ealk In Closer Clean floor 37.5 0.25 9.38 Carpet - Standard grade 37.5 0.00 0.00 Carpet pad - Standard grade 37.5 0.00 0.00 R&R Baseboard 3 1/4" 25 1.50 37.50 Paint baseboard - two coats 25 1.00 25.00 Drywal I replacement per LF -up to T tall 25 0.00 0.00 Texture drywall - light hand texture 200 0.75 150.00 R&R 5/8" drywall -hung, taped, ready for texture 37.5 2.00 75.00 R&R 5/8" drywall - hung & fire taped only 37.5 2.00 75.00 Texture drywall -heavy hand texture 37.5 0.75 28.13 Total Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision(agmail.com Page 12 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place Units 8301-8302 15000 Wymdham Place Blvd Sanford, FL 32773 Estimate Date Estimate # 9/9/2013 1183 Description Qty Rate Total Paint the walls and ceiling - two coats 237.5 1.50 356.25 R&R Batt insulation - 6" - R 19 - unfaced batt 15 6.00 90.00 R&R Blown -in insulation - 10" depth - R26 37.5 4.00 150.00 Bifold door - (2 slabs only) - Single - Detach & reset 1 0.00 0.00 Shelving -wire (vinyl coated) - Detach & reset 25 0.00 0.00 R&R Light fixture 1 0.00 0.00 Sprinkler head/escutcheon - Detach and reset 1 2.00 2.00 Seal truss system -up to 5/12 37.5 0.10 3.75 All labor and material is included All Permitting and Engineering is included. Total $20,749.13 Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 13 www.gfrenovations-com G&F Renovations Inc FL Division Lic#CCC1327280 Lic#CGC1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place 1500WVyndham Place Blvd. Sanfokd, FL 32773 Estimate Date Estimate # 9/3/2013 1173 Description Qty Rate Total Clean with pressure/chemical spray 384 1.75 672.00 Clean with pressure/chemical spray 768 1.75 1,344.00 Seal & paint stucco 768 1.00 768.00 Stucco repair around 3 doors 51 12.00 612.00 Seal & paint stucco band around doors = two coats 68 1.50 102.00 Paint the ceiling -two coats 384 1.50 576.00 Clean with pressure/chemical spray 72 1.75 126.00 Clean wiht pressure/chemical spray 144 1.75 252.00 Seal & paint stucco 144 1.00 144.00 Paint the ceiling -two coats 72 1.50 108.00 Staircase Front Clean with pressure/chemical spray 72 1.75 126.00 Clean with pressure/chemical spray 144 1.75 252.00 Seal & paint stucco 144 1.00 144.00 Paint the ceiling - two coats 72 1.50 108.00 All Labor and material is included. All Permitting and engineering is included . Total $13,549.00 Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com Page 2 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place 15001f Wyndham Place Blvd. Sanford, FL 32773 Estimate Date Estimate # 9/3/2013 1171 Description Qty Rate Total G&F Renovations would like to propose to do the following work. Roof SR&R Truss - 4/12 slope 390 15.00 5,850.00 R&R Sheathing -plywood -5/8" CDX 1,800 2.75 4,950.00 Carpenter -General Framer -per hour -trusses and sheathing 40 40.00 1,600.00 Carpenter -general framer- per hour- Deatch & reset Rodsand screws 16 40.00 640.00 Crane and operator- 5o ton capacity 16 150.00 2,400.00 Remove 3 tab- 25 yr. composition shingle roofing - inlc. felt 38 50.00 1,900.00 3 tab- 25 yr. composition shingle roofing- incl felt 44 175.00 7,700.00 R&R Roof vent -off ridge type 4" 2 35.00 70.00 R&R 2" x 4" lumber- treated (.^^& BF per LF)- top plates and other 240 4.00 960.00 misc framing R&R 2" x 6" lumber (I BF per LF)- misc framing 48 6.00 288.00 R&R 5/8" drywall - hung & fire taped only (38 x 10) +(48 x 10) + 940 4.00 3,760.00 (8 x 10) Tarp - all purpose poly- per sq ft (labor and material) - temp roof 500 2.50 1,250.00 protection during roof repairs R&R rafters - 2 x 6 -16" OC (3-5/12 Gable, per SF of floor)- roof 180 35.00 6,300.00 framing above stairways R&R Sheating- plywood -5/8" CDX- roofs above stairways 240 2.75 660.00 All labor and material is included All Permitting and engineering is included Total $38,328.00 Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivisionCgmail.com FLORIDA GENERAL DURABLE POWER OF ATTORNEY I, Eric Franco, President of G&F Renovations Inc. with headquarters office located at 1015 Union Hill Road Suite 7, Alpharetta GA 30004, and Florida office at 1572 Shadow Moss Cir Lake Mary FL 32746 hereby appoint Mr. Stephen Hall as my "Agent' to exercise the powers and discretions described below. This Power of Attorney shall not be affected by my subsequent incapacity. My Agent shall have power and authority to act on my behalf in regards to conduct my business with the City of Apopka, the City of Sanford, the Seminole County, the City of Lake Mary, obtaining certificates, permits, authorization, or documents needed to get such permits and/or certifications with the State of Florida. Including but not limited to make payments for such permits, certifications, and licenses. This power of attorney is effective immediately and will continue until November 30t", 2013. I am fully informed as to all the contents of this form and understand the full import of this grant of powers to my Agent. Signed this 23 day of QC-+ • , 2013 Eric Fra G&F Renovation's Inc. CERTIFICATE OF ACKNOWLEDMENT OF NOTARY PUBLIC State of FLORIDA County of Seminole O? v 13 nd q 19* This document was acknowledged before me on by etc I Lr err U Notary Seal ;n re of Aota ry Off' 8U8AN F LOMi�ARDO y Commission expire pryEggNNEEt8018i ~ EXPIRES January 28.2018 1=13 SOPA Parcel Vew..14-20-30-300-0080-0000 1 MULTIFAMILY 2001 324,432.00 CO Date Permit Date WOOD SIDING WITH S1,354,420 51,421,963 $75,000 10/01/2001 02167 Personal Property Sanford S1,500 WOOD OR META 01422 Addition - Commercial Description Area 576,500 04/01/2001 01335 Major Project - Commercial Sanford STUDS 03/01/2001 01333 OPEN PORCH 3504 Sanford 510,057 03/01/2001 01330 Major Project - Commercial Sanford S9,307 03/01/2001 FINISHED 2 MULTIFAMILY 2001 315,408.00 01336 WOODSIDINGWITH S836,345 5878,052 03/01/2001 01334 Major Project - Commercial Sanford $10,057 03/01/2001 WOOD OR META Major Project - Commercial Sanford Description Area 03/01/2001 01331 Major Project - Commercial Sanford $8,257 STUDS 01329 Major Project - Commercial OPEN PORCH 2976 $10,057 03/01/2001 01328 Major Project - Commercial Sanford $6,605 03/01/2001 FINISHED 3 MULTIFAMILY 2001 324,432.00 WOOD SIDING WITH 51,354,420 $1,421,963Description WOOD OR METAL Area STUDS OPEN PORCH 3504 FINISHED 4 MULTIFAMILY 2001 324,432.00 WOOD SIDING WITH S1,354,420 51,421,963 WOOD OR METAL Description Area STUDS OPEN PORCH 3504 FINISHED 5 MULTIFAMILY 2001 324,432.00 WOOD SIDING WITH $1,354,420 $1,421,963 WOOD OR META Description Area STUDS OPEN PORCH 3504 FINISHED 6 MULTIFAMILY 2001 324,432.00 WOOD SIDING WITH $1,354,420 51,421,963 WOOD OR METAL Description Area STUDS OPEN PORCH 3504 FINISHED 7 MULTIFAMILY 2001 320,000.00 WOOD SIDING WITH $1,129,314 $1,185,631 WOOD OR META Description Area STUDS OPEN PORCH 3504 FINISHED 8 MULTIFAMILY 2001 322,272.00 WOODSIDING WITH $1,196,350 $1,256,011 WOOD OR META Description Area STUDS OPEN PORCH 3360 FINISHED 9 MULTIFAMILY 2001 324,432.00 WOOD SIDING WITH S1,354,420 $1,421,963 WOOD OR METAL Description Area STUDS OPEN PORCH 3504 FINISHED 10 MULTIFAMILY 2001 3 15,408.00 WOOD SIDING WITH 5836,345 5878,052 WOOD OR METAL Description Area STUDS OPEN PORCH 2976 FINISHED 11 MULTIFAMILY 2001 322,272.00 WOOD SIDING WITH $1,196,350 $1,256,011 WOOD OR META Description Area STUDS OPEN PORCH 3360 FINISHED 12 WOOD 2001 1 5,217.00 STUCCO W/WOOD OR S373,737 5446,253 BEAM/COLUMN MTL STUDS Description Area OPEN PORCH 922 FINISHED OPEN PORCH 645 FINISHED OPEN PORCH 555 FINISHED Permits Permit # Type Agency Amount CO Date Permit Date 00063 Major Project - Commercial Sanford $75,000 10/01/2001 02167 Personal Property Sanford S1,500 07/01/2001 01422 Addition - Commercial Sanford 576,500 04/01/2001 01335 Major Project - Commercial Sanford $10,057 03/01/2001 01333 Mayor Project - Commercial Sanford 510,057 03/01/2001 01330 Major Project - Commercial Sanford S9,307 03/01/2001 01327 Major Project - Commercial Sanford $9,307 03/01/2001 01336 Major Project - Commercial Sanford 56,605 03/01/2001 01334 Major Project - Commercial Sanford $10,057 03/01/2001 01332 Major Project - Commercial Sanford $10,057 03/01/2001 01331 Major Project - Commercial Sanford $8,257 03/01/2001 01329 Major Project - Commercial Sanford $10,057 03/01/2001 01328 Major Project - Commercial Sanford $6,605 03/01/2001 I i m 47F.i Mai— PrniOrt - r—arrlall CanFnrrll %in nC71 I naim nnrrii i v►Mnnrscpd.orglParcelDetails.aspMD=1420-30-300-0080.0000 213 1=13 SCPA Parcel View. %24343040084000D < Back < Revious Parce-11 FiiTet layout New Search mmscpall.org/ParcelDetails.aspOMD=142a3D-30D-00840000 30 12W13 SCPA Parcel View.. %2D -M-300-00840000 p,..-b,,cm: Property Record Card 11311�Y Parcel: 14-20-30-300-0080-0000 �U-1111LAUFffin Owner: TWC SEVENTY-SIX LTD SEMI" LECOUNrY.FIORmA Property Address: 1500 WY NO HAMCREST BLVID SANFO RD, FL 32773 FZ_Sa­c_k1 I < Revious Parcel Next Parcel > Seve Layout Reset Layout New Search Parcel: 14-20.30.300.0080-0000 Property Address 1500 WYNDHAM CREST BLVD Owner. TWC SEVENTY-SIX LTD M ailing: 655 N FRANKLIN ST STE 2200 TAMPA, FL 33602 Facility Name: WYNDHAM RACE Tax District: S4-SANFORD- 17-92 REDVDST Exemptions DOR Use Code: 03 -MULTI FAMILY 10 OR MORE an T $ r3 � Q � Ar � � D p 4 � Map Aerial Both Footprint E+ D Extents Center Larger Map Advanced Map Dual Map View - Extemal Value Summary Tax Amount without SOH: $110,575 2013 Tax Bill Amount $110,575 Tax Estimator Save Our Homes Savings: SO • Does NOT INCLUDE Non Ad Valorem Assessments Legal Description SEC 14 TWP 20S RGE 30E ALL NW 1/4 OF NE 1/4 E OF RD (LESS N 940.52 FT) & 14-20.30.501-OA00.0010 LOT 1 & N 1/2 OF VACD ST ADJ ON S & LOT 2 (LESS BEG NW COR RUN E 200 FT S 134.)2 FT W 262.68 FT N 25 DEG 47 MIN E 148.05 FT TO BEG) & S 1/2 OF VACD ST ADJ ON N BLK A SUNLAND ESTATES PB 1 1 PG 17 Tax Details Taxing Authority 2014 Working 2013 Cert if led Taxable Value Values Values Valuation Income Income Method SO $5,423,164 Number of 12 12 Buildings SJWM(SaintJohns Water Management) 55,423,164 Depreciated Bldg $5,423,164 County Bondsl Value SO $5,423,164 Depreciated EXFT Value Land Value (Market) Land Value Ag lust/Market, SS,423,164 $5,423,164 Value •• Portability Adj Save Our Homes s0 SO Adj Amendment 1 SO $O Adj Assessed Value $5,423,164 $5,423,164 Tax Amount without SOH: $110,575 2013 Tax Bill Amount $110,575 Tax Estimator Save Our Homes Savings: SO • Does NOT INCLUDE Non Ad Valorem Assessments Legal Description SEC 14 TWP 20S RGE 30E ALL NW 1/4 OF NE 1/4 E OF RD (LESS N 940.52 FT) & 14-20.30.501-OA00.0010 LOT 1 & N 1/2 OF VACD ST ADJ ON S & LOT 2 (LESS BEG NW COR RUN E 200 FT S 134.)2 FT W 262.68 FT N 25 DEG 47 MIN E 148.05 FT TO BEG) & S 1/2 OF VACD ST ADJ ON N BLK A SUNLAND ESTATES PB 1 1 PG 17 Tax Details Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund $5,423,164 SO $5,423,164 Schools $5,423,164 SO $5,423,164 City Sanford S5,423,164 SO $5,423,164 SJWM(SaintJohns Water Management) 55,423,164 SO $5,423,164 County Bondsl S5,423,1641 SO $5,423,164 Sales Deed Datel Bookl Pagel Amount VacAm—p Qualifiei WARRANTY DEED 12/20001 owl =1 52,000,000 Vacant Ni WARRANTY DEED 01/19961 RL01 21 17011 59001000 Vacant Ye: Ind Comparable Sales within this Subdivision Land Methodl Frontagel Depthl U nit sl Unit Pricel Land Value LOTI 01 01 260.0001 5.000.001 $1,300,000 Building Inf omtation Description Year Buil Stories Total SF Ext Wall Adj Value Repl Value Appendages Actual/Ef f ect ive wwwst l.aglParcelDefails.aspWMD=14-2D-30.30D-0080-0000 1/3 U6t II -L D CITY OF SANFORD BUIL ING & FIRE PREVENTION PERMIT APPLICATION Application No: l Li ! CaeS,,- Documented Construction Value: $ A&00* 150010 U)yndinatkn Blvd Job Address: S FL 3:z 7-73 Historic District: Yes ❑ No,95- Parcel ID: 30- 3 Co - t2aln Zoning: Description of Work: Eyje ri o r ft4ert'a r- gj:ea irs Plan Review Contact Person: �ro'� Frrt'v c o Title: presile.,% Phone: If 6f - 3S 4 - 8 7417 Fax: 'Wt - 381- 8 79l E-mail: erc'e- t0 jfreno✓a-1 t o m; . co.,, Property Owner Information Name l he u k Ise.,, 6D y1r0,a Phone: Io7- 780 - o75Af v Street: 4-55 Nerd FrctnKliv► Sdreet- Resident of property? City, State Zip: �a!=gA FL 3 3 bo z3_ Contractor Information Name G£ F Renoya-H'ans3nC. IFr-ic t raeiLp Phone: `Fo`f- If7`f, `t 80 8 Street: I D1S Union W1141. St tijen 7 Fax: `F0 `f - iL'F8-'f %, 0 City, State Zip: A l p h are -V x, CA 3-000Y- State License No.: C G C 15 X 1 7 7 0 Architect/Engineer Information ccc I3;k7a8o Name: E PI Phone: 384 -• 73f - o 830 Street: 311-.A S Woodland 81 ed Fax: 3 e (a- 7 3 `f -- City, St, Zip: De (and FL E-mail: ee i@ e - P l e n u. n _t J Bonding Company: UJesfern Surd -u eorw,Ca Address: 5i'o u x FQII S 1j I So-" DoJ( 1-0. Building Permit ❑ Square Footage: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Dwelling Units: Flood Zone: Electrical ❑ New Service - No. of AMPS: Mechanical 13 (Duct layout required for new systems) No. of Stories: Plumbing ❑ New Construction - No. of Fixtures: Fire Sprinkler/Alarm 0 No. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. J�. ,al Q3 11.3 Signature of Owner/Agent Date Print uvirLAS ei&)4wC `7G of Florida Date SUSAN F 5 ' 6"" _y "11"1 =� ••= MY CONIMISSiq } 1a , f:1; • 1'10197 . • , �• EXPIRES Jr• •sir :t9, 20is ,1at���� — Floieean�om•, . • ...rte Owner/Agent is Personally Known to Me or Produced ID r/ Type of ID • APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 /0 %3.2013 Signature of ntractor/Agent Date Erl'c Fra n c o Print Contr o /Agent's Name "'WAN F L0MORDO MY COMMISSION#EE1e0183 EXPIRES January 28, 2018 Ronde oom Contractor/Agent is 1 -Personally Known to Me or Produced ID Type of ID UTILITIES: %& /2-r-/3 WASTE WATER: FIRE: BUILDING: DBPR - FRANCO, ERIC; Doing Business As: G & F RENOVATIONS, INC, Certified ... Page l of I 10. 12.15 AM 12/3/2013 Licensee Details Licensee Information Name: FRANCO, ERIC (Primary Name) G & F RENOVATIONS, INC (DBA Name) Main Address: 1015 UNION HILL ROAD SUITE 7 ALPHARETTA Georgia 30004 License Mailing: LicenseLocation: License Information License Type: Rank: License Number: Status: Licensure Date: Expires: Certified General Contractor Cert General CGC1521770 Current,Active 09/23/2013 08/31/2014 Special Qualifications Qualification Effective Construction Business 09/23/2013 View Related License Information View License Complaint 1940 North Monroe Street, Tallahassee FL 32399 :: Email: Customer Contact Center :: Customer Contact Center: 850.487.1395 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida. Privacy Statement Under Florida law, email addresses are public records. If you do not want your email address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. Please see our Chapter 4SS page to determine if you are affected by this change. https://www.rriyfloridalicense.com/LicenseDetail.asp?SID=&id=E3B3E3A5859CBEF24B... 12/3/2013 www.gfrenovations.com G&F Renovations Inc FL Division Lic#CCC 1327280 Lic#CGC 1521770 1015 Union Hill Road Suite 7 Alpharetta, GA 30004 Company: The Wilson Company 655 North Franklin Street Suite 2200 Tampa, FL 33602 Job Site: Wyndham Place 15000 Wyndham Place Blvd. Sanford, FL 32773 Estimate Date Estimate # 9/3/2013 1172 Description oty Rate Total G& F Renovations would like to propose to do the following work. Exterior R&R Fascia- I" x 4" - #I pine 148 4.00 592.00 Fascia - metal -6" 148 6.00 888.00 R&R Soffit - metal 148 5.00 740.00 R&R Sheating - plywood -1/2" CDX 400 4.00 1,600.00 R&R House wrap (air/moisture barrier) 400 3.00 1,200.00 R&R Siding -hardboard-lap pattern -6" 400 4.00 1,600.00 Seal & paint wood siding 3,472 1.00 3,472.00 R&R Trim board- 1" x 4"- installed (pine)- around windows + 48 4.00 192.00 siding trim Seal & paint trim - two coats 48 1.00 48.00 R&R Gutter/downspout-aluminium-6" 32 7.00 224.00 R&R Metal lath & stucco 72 14.00 1,008.00 Seal & paint stucco - outside of stairway walls 1,080 1.00 1,080.00 Plumber - per hour- Detach & Reset fire sprinkler pipe in attic 8 75.00 600.00 during truss removal All Labor and material is included All permitting and engineering is included . Total $13,244.00 Phone # Fax # E-mail 404-474-4808 404-448-4460 gfreno.fldivision@gmail.com TWC: Seventy -Six, Ltd. Dba Wyndham Place Apartments Date: September 27, 2013 THIS AGREEMENT made and entered into by and between TWC Seventy -Six, Ltd. hereinafter referred to as OWNER, CONTRACTOR, as listed below and hereinafter referred to as CONTRACTOR. Service to be performed at Wyndham Place Apartments, hereinafter referred to as PROPERTY. Contractor Address City Telephone Contact Terms for a period: FROM Commence by: 09/30/13 Completed by: 12/02/13 G&F Renovations Inc. FL Division 1015 Union Hill Road, Suite 7 Alpharetta, GA 30004 404474-4809 09/30/13 TO 12/02/13 CONTRACT AMOUNT $141,850.76 The OWNER agrees to pay to the CONTRACTOR for the satisfactory performance and completion of the Work and all of the duties, obligations and responsibilities of CONTRACTOR under this Agreement, the contract amount listed above, which shall be paid upon completion. Payments made within 30 days of receipt of invoice provided that CONTRACTOR shall have fulfilled all of the satisfactory obligations to be performed by CONTRACTOR under this Agreement and the Owner or the Owner's Authorized Agent has accepted the work. CONTRACTOR agrees to furnish all labor, materials and equipment necessary to perform the work in accordance with their attached proposal. Contractor's proposal is attached only to serve as a description of the work, no other provisions of the proposal shall be allowed to take precedence over the terms of this agreement unless it offers warranty or guarantee periods in excess of those required by this document. SCOPE OF WORK: See attached proposal Restore building to pre -fire condition according to Revised Insurance Adjuster scope of work. Work to include apartments 8-301 and 8-302. All exterior including roof, trusses, siding, breezeways and staircases. Liquidated damages of $24.36 per unit per day for loss of rent if contractor does not complete project on given date according to schedule. Number based on current rent $731.00 per month divided by 30 days. Payment schedule is as follows: 30% - $42,555.76 - upon Mobilization 300/9 - $42,555.00 - 50% of completion 30% - $42,555.00 - 75% of completion 10% - $14,185.00 - 30 days after completion This agreement specifically includes TWC Seventy -Six, Ltd., Short form Contract, General Conditions (pages 1& 2 of 2) By: TWC Seventy -Six, Ltd. By: TWC Seventy -Six Partners, Ltd., its GP By: TWC Seventy -Six, Inc., its GP Signature _ - / 'k - Name: Scott Wilson Title: Vice -President Date: Contractor: G&F Renovations Inc. FL Division By: Name: r'1 G t Gi vlC a Title: Date: �f�5 i CiCrti-F Cl 1'30113 TWC Seventy -Six, Ltd. Contract General Conditions A. CONTRACTOR hereby agrees that the Work will be performed in strict accordance with the specifications on the Contract Documents herein defined. CONTRACTOR agrees to perform the Work to the NII satisfaction of the OWNER and/or his authorized agent. CONTRACTOR shall commence the Work immediately when notified by OWNER and shall execute said WORK in a good and workmanlike manner with due diligence and without delay. The OWNER reserves the right to have any portion of the Work, for which the CONTRACTOR has not been directed to proceed, accomplished by his own forces or by others. B. Time is of the essence in the performance of the Work referred to in this Agreemem, in as much as failure of the CONTRACTOR to commence and complete the Work as and when required by the OWNER may cause grave injury and damage to the OWNER by virtue of loss of sales and good will, delayed receipt of income from rental units, extension of overhead costs and otherwise. Accordingly, the CONTRACTOR agrees to prosecute the Work with due diligence and will not in any manner delay or otherwise interfere with the work of the OWNER or other Subcontractors. C. CONTRACTOR acknowledges that no liens shall be attached to the real estate by virtue of any work done hereunder by the CONTRACTOR or by any suppliers, employees, material men, or other Subcontractors employed by him; and the CONTRACTOR warrants that all sucb parties shall be advised of same and certifies to the OWNER that they are aware thereof and bound thereby. OWNER has the right to request Waivers of Lien to be relinquished by CONTRACTOR as payments are received. Full Waives of Lien and Affidavits may be required from the CONTRACTOR prior to final and !lull Payment. D. CONTRACTOR shall maintain at all times, while obligated to perform under the terms of the contract, the following insurance coverage: 1. A policy of workmen's compensation and employer's liability insurance, with a limit of no less than Five Hundred Thousand dollars S500.000.00) for the protection of CONTRACTOR's employees, including, without limitation, executive, managerial and supervisory employees, engaged in the work. Il. Proof of insurance for any and all vehicles, with a minimum of no less than One Million dollars (31.000.000.001 to be used by the CONTRACTOR in order to perform his services. III. A policy of general liability insurance including completed operations covering loss resulting from the CONTRACTOR'S direct and indirect activities hereunder, whether performed by CONTRACTOR or by its Subcontractors or suppliers, and covering injury and damage to any person employed by CONTRACTOR and its Subcontractors and suppliers, and all others who might be injured or damaged as a result of performance of the work, and covering damage to property. The minimum bodily injury coverage (including death) shall not be less than One Million dollars (SI.000.000.001 for each occurrence. The property damage coverage required herein shall not be less than One Million dollars (SI".000.00) for each occurrence and shall protect the work, and any improvements on the property adjacent to the area where the work is being performed. If said bodily injury and property damage coverage are combined, total amount of coverage is to be One Million dollars (SI.000.00.00) IV. Coverage requirements are to be evidenced by providing a Certificate of Insurance naming the OWNER and TWC Seventy -Sox, Ltd. As Certificate Holder and shall provide that such policy may not be (i) candid, (o) allowed to expire, or (iii) reduced in its coverage limits without thirty (30) days prior written notice to the Certificate Holder. V. CONTRACTOR SHALL, CONCURRENTLY WITH ITS EXECUTION HEREOF, DELIVER TO THE CERTIFICATE HOLDER THE CERTIFICATE OF INSURANCE REFLECTING INFORMATION OUTLINED ABOVE. E. Provide the Community with a copy of MSDS for any and all materials used on the property. F. The OWNER, or his representative, may order changes in the work, consisting of additions, deletions, or other revisions, the Contract price and the Contract time being adjusted accordingly. The OWNER shall authorize all such changes in the work in writing. G. CONTRACTOR shall indemnify and hold the OWNER. OWNER's agents and to Property frce of and harmless from any and all actions or causes of action, claims, demands, liabilities, losses, damages or expenses of any kind and name, including attorney's fees, which the OWNER, OWNER'S agents or the Property shall or may at any time sustain or be liable for in consequence of any injury or damage to person or property which may arise directly or indirectly from the performance of this Contract by the CONTRACTOR and its subcontracts, material men, supplies, and anyone directly or indirectly employed by or acting for any of them. H. CONTRACTOR shall at all times keep the premises free from accumulation of waste materials or rubbish caused by its performance of the work. 1. The CONTRACTOR shall be responsible to the OWNER for the axis and omissions of all CONTRACTOR's employees and all Subcontractors, their agents and employees, and all other persons performing any of the work for said CONTRACTOR. The CONTRACTOR shall be responsible for any and all damages caused by his employees, agents, or representatives and shall repair all damages to the condition that existed before said changes took place or reimburse OWNER for making repairs. J. The CONTRACTOR shall obtain all permits and license that may be necessary for the proper performance of this Work. The CONTRACTOR, and all acting under is direction or control, shall take all necessary precautions for the safety of employees performing the work and shall at all times comply with all Local, State and Federal statutes, ordinances, rules and regulations, as well as those of other public body having authority concerning the Work. The CONTRACTOR shall hold and save the OWNER harmless and indemnified against all claims arising out of any violations or noncompliance with the provisions of the article. IC The CONTRACTOR shall pay all Sales Taxes, F.I.C.A. and Unemployment Compensation Taxes upon the material and labor fumished under this Contract, as required by the United States Government and the State in which this work is performed. L. ALL CONTRACTOR's personnel must wear uniforms with identifying nametags or embroidery telling the name of the company, as well as the employee's name. M. All work is to be performed at a time and in a manner that will least disrupt the Residents of the Community. No employee will be them before 8:00 a.m. or after 6:00 p.m. — Monday through Saturday unless authorized by Owner. N. This Contract shall not be assigned by the CONTRACTOR without first obtaining permission in writing from the OWNER. 0. CONTRACTOR shall be responsible for the protection of the OWNER's property or public or private adjacent to the Property at all times. Owner/Owner's Rep Initials/Date: Contractor loltalsMate: q 4,bl I 3 7WC SeventySlz, Ltd. Contract General Conditions P. CONTRACTOR agrees to conform to the progress schedule, which the OWNER shall issue. Q. All equipment. materials and articles used in the work covered by this contract shall be of most suitable grade of their respective kinds for the purpose. R. The CONTRACTOR shall promptly notify the OWNER in writing of any or all conditions which. in his opinion, will affect the satisfactory execution of his Work or endanger its permanence. Upon beginning work, the contractor shall be liable for correcting all work and materials which produce an unsatisfactory installation according to standard methods, techniques, and practices within the industry or that do not conform to applicable specifications, drawings, building codes, or government regulations. S. The CONTRACTOR shall supervise and direct the work. The CONTRACTOR shall notify the Property Manager 48 hours in advance of manning the job and shall at all times enforce strict discipline and good order among his employees. The CONTRACTOR shall have present on the property, a designated Forman as his representative who shall be responsible for the work and the CONTRACTOR's employees. T. The CONTRACTOR shall be responsible for initiating maintaining and supervising appropriate safety precautions in connection with his wort. He shall take all reasonable precautions for the safety of his employees, agents and residents of the property. The CONTRACTOR shall comply with all appropriate OSHA regulations and procedures, and shall make all reasonable efforts to protect his work in progress. U. As to Permits and Cerificates, the CONTRACTOR shall comply with the rules and regulations and requirements of all legally constituted authorities. The certificates of approval of the authorities shall be delivered to the Property Manager before payment will be authorized. Failure of die Property to demand these approvals shall not constitute a waiver of this clause. V. CONTRACTOR guarantees that all the Work shall be free from defects in worknumship and materials for a minimum period of one (1) year from the date OWNER accepts the Work and promptly upon OWNER's request will correct by repair or replacements, without charge, any such defects (and any damage to other property, including without limitation the work of other Subcontractors resulting therefrom or from the correction thereof) which may appear in the Work during that period In the event that Contractor's attached proposal offers guarantees or warrantees in excess of one (1) year, that specific provision of the Contractor's proposal shall take precedence over this minimum requirement. W. The OWNER, at its sole discretion, may terminato this Agreement at any time by giving at least thirty (30) days prior written notice of such termination to the CONTRACTOR with a written notice delivered to the CONTRACTOR via Certified Mail. Upon any termination of this Agrccmeny and subject to all the terms and provisions herein contained, the CONTRACTOR shall be entitled to payment at the contract price for all accepted work furnished or installed by him. However, the OWNER may retain from any monies due to the Contractor, an amount sufficient to cover CONTRACTOR's obligations under the guarantee of materials and workmanship as contained herein. Upon the expiration of such obligations, the balance of such amount if any, shall be paid to the CONTRACTOR. The CONTRACTOR upon termination of this Agreement, shall forthwith peaceably and quietly surrender to the OWNER all premises, facilities, machinery, and equipment by or belonging to the OWNER. X. This Contract shall be construed and enforced in accordance with the laws of the State where Property is located. Y. CONTRACT IS NOT VALID UNTIL THE SIGNATURE OF THE APPROPRIATE OWNER'S REPRESENTATIVE AND DATE OF EXECUTION THEREBY HAS BEEN PLACED HEREON. CONTRACTOR IS NOT AUTHORIZED TO AND SHALL NOT COMMENCE WORK UNTIL SUCH TIME AS ALLOWED IN THIS DOCUMENT. Owner/Owner's Rep Inldals/Date: Contractor loldals/Date: i q 13 Detail by Entity Name etail by Entity Name SEVENTY-SIX, LTD. ocument Number EI/EIN Number ate Filed st Event ent Date Filed ent Effective Date A98000002347 593536571 10/12/1998 FL ACTIVE LP AMENDMENT 09/27/2012 NONE 55 NORTH FRANKLIN STREET, SUITE 2200 RMPA, FL 33602 anged: 05/04/2000 55 NORTH FRANKLIN STREET, SUITE 2200 AMPA, FL 33602 hanged: 05/04/2000 ✓ILSON, CAROLYN M 55 NORTH FRANKLIN STREET, SUITE 2200 AMPA, FL 33602 me Changed: 02/15/2011 Changed: 04/29/2005 me & Address ment Number A98000002346 WC SEVENTY-SIX PARTNERS, LTD. 55 NORTH FRANKLIN STREET, SUITE 2200 AMPA, FL 33602 Page l of 3 http://search.sunbiz.org/1 nquiry/CorporationSearch/SearchResultDetaillEntityNameldomlp... 12/3/2013 Detail by Entity Name Report Year Filed Date 2011 02/15/2011 2012 03/21/2012 2013 04/02/2013 Page 2 of 3 04/02/2013 -- ANNUAL REPORT View image in PDF format 09/27/2012 -- LP Amendment View image in PDF format 03/21/2012 -- ANNUAL REPORT View image in PDF format 02/15/2011 -- ANNUAL REPORT View image in PDF format 04/28/2010 -- ANNUAL REPORT i View image in PDF format 01/27/2009 -- ANNUAL REPORT I View image in PDF format 04/22/2008 -- ANNUAL REPORT r View image in PDF format 04/27/2007 -- ANNUAL REPORT View image in PDF format 04/17/2006 -- ANNUAL REPORT View image in PDF format 04/29/2005 -- ANNUAL REPORT View image in PDF format 05/04/2004 -- ANNUAL REPORT I View image in PDF format 05/12/2003 -- ANNUAL REPORT View image in PDF format 05/12/2003 -- Contribution Change! View image in PDF format 05/01/2002 -- ANNUAL REPORT View image in PDF format 05/01/2001 --ANNUAL REPORT i View image in PDF format 05/01/2001 -- Contribution Change View image in PDF format 05/04/2000 --ANNUAL REPORT i View image in PDF format 12/11/1998 --ANNUAL REPORT View image in PDF format 10/12/1998 -- Domestic LP I View image in PDF format Copyright ® and Privacy Policies State of Florida, Department of State http://search.sunbiz.org/lnquiry/CorporationSearch/SearchResuItDetai 1/EntityName/domlp... 12/3/2013 FLORIDA GENERAL DURABLE POWER OF ATTORNEY I, Eric Franco, with headquarters office located at 1015 Union Hill Road Suite 7, Alpharetta GA 30004, and FL office located at 1572 Shadow Moss Circle Lake Mary, FL 32746; hereby appoint Ms. Susan F Lombardo as my "Agent" to exercise the powers and discretions described below. This Power of Attorney shall not be affected by my subsequent incapacity. My Agent shall have full power and authority to act on my behalf. This power and authority shall authorize my Agent to manage and conduct all of my affairs and to exercise all my legal rights and powers, including all rights and powers that I may acquire in the future. My Agent's powers shall include, but not limited to, the power to: 1. Conduct my business with the City of Sanford, the Hillsborough County, the Seminole County, the City of Lake Mary, obtaining certificates, permits, authorization, or documents needed to get such permits and/or certifications with the State of Florida. This power of attorney is effective immediately and will continue until it is revoked. I am fully informed as to all the contents of this form and understand the full import of this grant of powers to my Agent. Signed this A3 day of O - , 2013 Erican o G&F novations Inc. CERTIFICATE OF ACKNOWLEDMENT OF NOTARY PUBLIC State of Georgia County of Fulton This document was acknowledged before me on &J. A3 by Erle firav►4-�o Ana Marie Franco NOTARY PUBLIC Fuhon Courrry, GEORGIA My Comm. Expires 47/2018 Notary Seal e /ice 2Z. a�Ewy— Signature of Notary Officer My Commission expires: GV 7 " FROM : '• PHONE NO. : 4076548194 Jan. 27 2014 02:52PM P1/3 CITY OF SANFORD 20UILDING & FIRE PREVENTION PERMIT APPLICATION Application No: / y ' Li3 3 Documented Construction Value: S-13 '50 90 Job Address: /SDO W �i-gm 6vaSf 8/rte( S'Ar,rE'oY,� aZ7Hi toric District. Yes D No ❑ Parcel XD: %y- Z0 -30-300 --OV90 -0000 Zoning: Description of Work: /ASA11nlcw Rtz .4 %a,.Jl r-, C�° Tu>n sem' ii�NS aF'�u[f s To 5 Z K w Neal Title: r, Ilt Plan Review Contact Person: Title: Phone: Fax: E-mail: Property Owner Information Name SMC'Se(/pntY_ lC �� Phone: Street: /S"oe Wa2dhaa e, -est Blvd, Resident of property? City, State Zip: —2 A ori 4Z. 34773 Contractor Information Name S%P_rriad a - tyakesd Phone: 1/07 Z77 -;,77 Street: <f l'27 ;5, Fax: �4a7 - 381 - 2-z.7-,7 City, State Zip: CA `4f�M49' Al. 34709 State License No.: C Mt'__el c1gD_ 33 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: Bonding Company: Address: Building Permit O Square Footage: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Stories: No. of Dwelling Units: Flood Zone: Electrical D New Service - No. of AMPS: Mechanical EY (Duct layout required for new systems) Plumbing D New Construction - No. of Fixtures: Fire Sprinkler/Alarm 13 No. of heads: FROM : Jan.27.2014 08:51 AM PHONE NO. : 4076548194 Jan. 27 2014 02:52PM P2/3 PAGE. 2/ 2 Application is bereby made to obtain a permit to do *a work and installations as indicated. I ecrtdy that no wwk or itaostatWion has commenced prior to the ismance of a permit and tint All work Will be performed to meet standards of all laws regulattttg construction in this jurisdicticm. I understand that a upwate pwmh must be secured for dutrlesl work, plsmblu& atgets, wells, pooh, furnaces, begas6 beaters, tasks, and miff "adltteteent etc. QWNZ6!AAIiFIDAVIT; I eerdfjr fiat lir of this bmplog Infermefts b a ccatrste slid fiat ONwork will he done In compdanca with ILII appNcable lawn regulating ooeestruetles and am lhag, WAR.K1MG TO OWNER: YOUR FAILURE TO RRCORD A NOTICE OF COhMMMEMENT MAY RESULT IN YOUR PAYING TWICE FOA IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMRNCEMENT MUST U RECORDED AND POSTII.D ON THE 308 SITE BEFORE THE FIPW INW9CTION. IF YOU INTEND TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RZCORUING YOUR NOTICE OF COMMENCEMENT. NtYtICIR: in addition to tha rcquirrMetttS Of this pestnit, there may bo wMtiwanl msuictions atrplicable to this ptopcny that may be found in the public n=ub of this musty, and there may be edditionnl poa<mity required from miter governmental entities stub vs water muMcment diatrictw, Rtate agencies, or federal agencies. Acceptance of permit is veritteadon that 1 wig notify 6a owner of the property OF the roquiranvttts of Florida Lien Law, FS 713, The City of Sanford requires payment of it plan review ft. A copy of the ctecated contract is required in order to calculate a plan r vista charge. If the eaceeuW oantract is not submitted, we reserve the right so calculate the plan rrAcw fee based on past ptatmdt activity levels. Should calculated charges excecd The documented construction value when the executed coneW is m1bmined. coedit will be appliod to your permit fees when the permit U released. '/Y" - " L' Z' �' Zl- I -a - �y sl prow"FlAr r nee I -a-?-ry SAMANTHA MARIE WALDROP MY COMMISSION a EED42774 EXPIRES November 17, 2014 0wowr/Agent in P&u0nally Ka 0%%— t- Glc or Produced ID 7�pc of Ib _ I - ay -ry SAMANTHA MARIE WALDROP ip MY COMMISSION 0 EED42774 EXPIRES November 17,2014 F*Mb WSWWQ*- M Cortr+caa/ASmt is y Aftim n to Mc or Round ID - Tyco of tv APPROVALS: ZONING: UMLIM: WASTE WATER: bNOINEERWO: FME: BUMDING: COMMENTS: R av t 1.04 FROM ' PHONE NO. 4076548194 Jan. 27 2014 02:53PM P3/3 N�0.�. (�. 1•�,� .7 r1Y� WI�:�l VVA ;`I' N I,y J.0 r I rcm PHME N0, 4076SQ194 Jan, 27 2014 18: 21AM Pi/1 WATSoiV'S TOTAL AIR INVOICE# i sn» CeNfeN /OdGa{IeDi .• (407) 277.1771 TAAl24927 9. Col=W Dr. Ch4ltmss, FL 32709 1.000-909.2661 arr+e t+LA lI naw Q ROOM .eooPsc r�rr.w •rsovr � �P[TaAL orrmr r..a.Nw Lreoa o�.L eoneMuuees►lu+ ar«s weoa �t vatrenrenao D cow nisQ n ! ' t >" ' &X 4NA- vwca P061 CHEM 7aT MEMO o nts,._-•—r--Poo ° O0C—.r "01 U YOLIS o,oy--i_., Ao o c0 bP� cs so 0 MNA_/`—RM1eD COWDsnxR COIL 7 CVAR _ 7 nwe4Nomw a WNW _. a tw 0 QK FAN AMD Af4I4g A/AN / � D MlulrAblr ►0`tlAT U WpbCATiON d#�TAICNPr1T9TRlP9 4 Atls 1 wm Norm" COH a elm rp O AVOW — 7F S jAMIfl ow3mwwk AIR r<LM V ��� 1011"A1R.CO1V0Yi10Nw0; 1 odmowled@a tfwt repaim Mw boin porfoiriwd In s' "now atloFoetari to M4. In the bwnt.vsyM6 t .0- eot mode as agreed, ft-Ab001 bee w peer ell Oft of collection, Including a recto am emmey/e �I decfen of!8!! n added x ..—� ......... �.... AVR[e�ObR0 1L� 1 cer* I he to mod os incdcoted and IM/Ila R1111{�d ttwr'ieM.+ms PAM WARSAW nOhhr�hNoerd�sondw�onvOd�� po/Carr1�IL�wr�pLealaLiera uttofa awftAwTa�utvtarwrat 1ho Wmr dwp brow sh boo tow" 0 �► r oormod w Rema 4 [or o pdw of 1 sd e*db ginrd� �01H' OUR TOAIN�D PAfa50nrIB Sv00r4T TME PO"WINO IMPROVELINTS: 0 idMq Wp LAM �j 0 Nor willoomeas P011/►IV+I WAM W11MAQfi 0 ,rcoce.uaep P1J<LTOSItOIALdWtWd D Pco.mpcw Claim pau 0 r3 1..r wAu eteet, Akbse PLf/ViEPrC�VYa�o�� A1pIpA • I DEC 0 9 2013 I City of Sanford F D '.Commercial- Permit Application Checklist P� �r All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. Gam Copy of the contractor's license issued by the State of Florida (if contractor is applicant). p� A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of /Florida (must be submitted with each application if contractor is the applicant). GY Completed, signed, and notarized Property Owner Builder Disclosure Statement Affidavit (if owner is applicant). O Approval letter from sanitary sewer provider (if other than the City of Sanford). O Copy of the onsite sewage disposal system construction permit issued by Seminole County Health Department for new or existing septic systems, grease interceptors, etc. (if applicable). O Seminole County Impact Fee Statement. 2` ? Five (5) sets signed and sealed building construction plans. 0 Two (2) sets signed and sealed site development plans approved by City of Sanford Planning & Development Services Department. p/ Two (2) sets signed and sealed floor and roof truss engineering. D Completed and signed Statewide Product Approval Specification Form. D Two (2) copies of the manufacturer's installation instructions for the following products- windows, doors, roofing materials, engineered lumber products, glass blocks, soffit materials and siding. D Three (3) sets of completed and signed energy calculations (signed/sealed if required by Florida Statute or code). O State of Florida Division of Hotel and Restaurant approval (if applicable). O Florida Department of Environmental Protection Notice of Asbestos Renovation or Demolition (if applicable). O State of Florida Notification on Gas Tanks (if applicable). THE CONSTRUCTION DOCUMENTS MUST INCLUDE, AT A MINIMUM, THE FOLLOWING: SITE PLAN All parking and accessible routes Accessible parking space(s) and signage details Accessible entrances Accessible ramps, handrails, guardrails, curb cuts and details All required building exits accessible (not less than 60% if all are not required exits) Areas of rescue assistance Accessible signage Fire access Vehicle loading Driving/turning radius Fire hydrant/water supply/post indicator valve (PIV) Location of septic systems (if applicable) Setbacks/fire separation (assumed property lines) Utility lines (water, sewer, irrigation November 2013 Page I of 7 Commercial Permit Application Guidelines D Meters and backflow devices B LDING PLAN Construction documents shall indicate code edition being applied D Page size minimum 11" x 17" • • Plans to minimum 1/8"scale All pages numbered and labeled pJ Plans signed/sealed and dated by a Florida Design Professional as applicable O Designer information: name, address, registration # on all pages p� Reference the currently adopted code editions O Wind design data required on drawings per FBC 1603.1.4 to meet 129 mph ultimate design wind speed for risk category I buildings, 139 mph ultimate design wind speed for risk category II buildings and 149 mph ultimate design wind speed for risk category III and IV buildings • Ultimate design wind speed (Vult) • Nominal design wind speed (Vasd) • Risk category • Exposure category • Enclosure classification • Internal pressure coefficient • Component and cladding design wind pressures in terms of psf • Structural Calculations, if necessary Threshold Inspection Plan (for threshold buildings) All areas dimensioned and use noted Corridors Shafts and elevator hoistways Stair location/guardrails/handrails Partition denotations and schedule Door locations, sizes, door and hardware schedule Window locations, sizes and schedule Tempered glass locations Attic ventilation and access Air barrier requirements Interior finish ratings and schedule Light and ventilation Sanitation Elevators Escalators Lifts Roof coverings Construction type design criteria: V,'� Type of construction denoted (per table 503) O Occupancy group classification denoted for building and rooms/areas D Gross square footage — Net square footage calculations O Building height O Percentage of exterior openings calculations O Classification of hazard of contents (if applicable) tructural Design Criteria: DUltimate design wind speed (Vult) O Nominal design wind speed (Vasd) ,\Risk category Revised: Nkember 2013 Page 2 of 7 Commercial Permit Application Guidelines D Exposure category Enclosure classification D Internal pressure coefficient D Component and cladding design wind pressures in terns of psf D Structural Calculations, if necessary D Floor loads — psf D D tair loads — psf oof loads — psf O lcony loads — psf D Co 'dor loads — psf D Sto ge loads — psf Materials to be reviewed shall at a minimum include the following: D Wood / grade — species D Steel / type - grade O Aluminum D Concrete D Plastic D Glass O Masonry O Gypsum board and plaster O/ Insulating (mechanical) ; Roofing C� Insulation O Alternate materials tructural: Signed and sealed soil report with a positive conclusion required O Compaction requirements D Foundation locations, dimensions and depth specified D Foundation denotations, schedules and details D einforcing steel, amount, size, grade, spacing, and lap specified D ooting dowel locations O ximum filled cell spacing D E edment's Sla thickness and reinforcement Vapo barrier Tenni t p Relieve 7eials 1 details at pipe penetrations Brick lencluding flashing and weep hole size and spacing Building used Lintel loc notations and schedule Exterior anr structural wal•I sections Columns Tie beams Structural steel size, ype Framing details and f to Load path connectors Floor deck and fastening Wall sheathing and faster Roof deck and fastening Stair construction Revised: November 2013 connections Page 3 of 7 Commercial Permit Application Guidelines Window and door details, including design pressure of openings O Fastening details for windows and doors, (type, length, and quantity) D Exterior mounted mechanical units fastening methods to meet wind load O Roof and floor framing, truss layout, connector schedule Fire Pro ction Requirements: O Fi separation requirements for corridors, elevators, stairways, floors & shafts O Oc pancy separation requirements O Tena t separation requirements D Fire r istant protection details for type of construction D Rated r uirements for walls, floor -ceiling and roof -ceiling assemblies O Design n mbers and details for all rated assemblies O Design nu bers and details for all rated penetrations O Rated door d hardware schedules D Fire blocking nd draft stopping D Calculated fire esistance O Interior finishes ame spread/smoke development) Life Safety: O Occupant load calcul tions and egress capacities O Special occupancy req 'rements D Egress plan • Number of exits O Capacity of exits O Arrangement of exits O Travel distance to exits/comm a f travel O Stairs construction/geom n e tion O Horizontal exits/exit passa e O Illumination of exits • Exit signs O Emergency lighting • Enclosures • Handrails • Guardrails O Ramps O Early warning systems schematic O Smoke control systems schematic O Stair pressurization systems schematic O Extinguishing requirements D Areas of rescue assistance Accessibility Building: D Door sizes, hardware schedule O Vertical accessibility D Accessible route dimensions O Maneuvering clearances O Hi -Lo drinking fountain O Equipment clear floor space/reach ranges • Areas of rescue assistance O Signage D ATM machines Accessibility Restrooms/Bathrooms: Revised: November 2013 Page 4 of 7 Commercial Permit Application Guidelines O Turning radius O Required floor space for fixtures Fixture and equipment mounting dimensions Adaptability ible requirements for special occupancies in addition to general requirements will also be reviewed. umbing plans submitted Pi 'ng materials Pip' supports D eten ine minimum plumbing fixtures required based on occupant load calculated per FBC 1004 Water tribution diagram Water ha er arrestors Plumbing in, waste and vent riser diagram Grease trap tail Grease trap He Interceptors Roof drains/calc Backflow prever Medical gas Oxygen systems Environmental n Dept. report on existing for flat roofs Water Heaters: O T&Pdrain O Air gap O Pan drain O Thermal expansion device O Heat traps O Mounting platform GAS PLAN \ O Type of gas O Gas pressure O Appliances schedule and BTU's O Chimneys and Vents O Combustion air O LP tank size and location (above or below grade) O Protection requirements Gas Riser Diagram: O Pipe type O Pipe sizing O Total developed length O Segment lengths O Appliance locations O Shut -offs valves MECHANICAL PLAN O Mechanical plans submitted O Energy calculations O Duct systems and sizing Revised: November 2013 Page 5 of 7 Commercial Permit Application Guidelines etwork clearances at mechanical room (4" minimum) Du t supports Mea for balancing HVAC system Diffuse (size and direction) CFM req irements Ventilatio Outdoor air c lculations Balanced retu air Make-up air Equipment loca 'on and working clearances ( 30" wide by 36" deep, 6' high minimum) Condensate pipi and disposal Required platfo and catwalks Roof mounted equ ment (including equipment and curb anchorage) Details and specific tions Equipment sizing ca ulations Equipment specifcati s Joint sealing methods a d product specification Air balance table Rated penetrations - fire d mpe Means for automatic fan sh td( Kitchen hood, duct plans, fir s Bathroom exhaust systems Special exhaust systems Chimneys, fireplaces and vents Other appliances Boilers Refrigeration Bathroom ventilation Laboratory details and manufacturer's installation instructions and specifications LI ELECTRICAL PLAN O Maximum available fault current at servic\overclu O AIC rating of equipment O Voltage and phase of electrical system O Load calculation O Electrical service riser diagram indicating sizes, number of service disconnecting means, grc steel, structural steel, metal piping, size and type, switching) O Transformer sizes and types if used O Panel schedules and ratings O Power plan O Panel locations and working clearances O Lighting plan O Device legend O Wiring methods and materials O Feeders and branch circuits, conduit sizes and types O Grounding conductors O Exit lights O Emergency lighting O Egress lighting protection sizes, conductor and conduit types and ding electrode system: bonded to the foundation )arately derived system or not? (solid neutral or Revised: November 2013 Page 6 of 7 Commercial Permit Application Guidelines Signage nd disconnecting means location Generator e. emergency or standby Remote ann nciation Load shed (i ecessary) Required recep acle out GFCI's Equipment Special occupancie Emergency systems Communication syste s Low voltage Early warning smoke evad Sprinkler design criterion ( Fire alarm design criterion Pre-engineered systems Riser diagram Standpipes 3SION and cont 1 permit required) permit required) These guidelines were compiled to assista applicant in preparing a new commercial permit/plan submittal and may not be complete. The applicant 's required to meet all City of Sanford, state, and federal code requirements. Please be aware that a separa permit is required for any fire sprinkler system and fire alarm system. All site related signs, fences, hardscap eatures, guard/hand rails, free standing walls, retaining walls, canopies, accessory structures, site electrical id lighting, satellite dishes, dumpster enclosures, irrigation systems, lift stations, and any demolition of struetit s. Revised: November 2013 Page 7 of 7 Commercial Permit Application Guidelines