Loading...
HomeMy WebLinkAbout380 Red Rose LnOil' �o D � C OCT - 4 2015 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION I/ �- 1 (17 1/6 Application No: Documented Construction Value: S 3^7(08 )1 A y Job Address: �O ��L L Historic District: Yes ❑ No Parcel ID: 2119-30-ra -0000-003 0 Residential Q Commercial ❑ Type of Work: New ❑X Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Plan Review Contact Person: Daphne Clark Title: Phone: 407-257-6940 Fax: Email: daphneQ PermftsPermitsPerm its.com Property Owner Information Name TAYLOR MORRISON OF FLORIDA INC Street: 151 SOUTHHALL LANE # 200 City, State Zip: MAITLAND FL 32751 Phone 407-629-0077 Resident of property? : NO Contractor Information Name JOHN ASA WRIGHT / TAYLOR MORRISON OF FLORIDA Phone: 407-257-6940 Street: 151 SOUTHHALL LANE # 200 Fax: City, State Zip: MAITLAND FL 32751 State License No.: Architect/Engineer Information Name: Street: City, St, Zip: Phone: Fax: E-mail: Bonding Company: N/A Mortgage Lender: N/A Address: Address: CBC1257462 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised. June 30, 2015 Permit Application e7 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. �i Signature Owner/Agent 7 date TAYLOR MORRISON OF FLORIDA INC Print Owner/Agent's N e Signature of ft * -State of Florida to .►�Y ►� D. A CLARK � *°�� MY COMMISSION I FF 209108 * EXPIRES: June 27, 2019 ' a d' l3aded mru Budw Notory SOW Owner/Agent is YES Personally Known to Me or Produced ID N/A Type of ID � 3C Signature ontractor/Agent Date JOHN ASA WRIGHT Print Contractor/Agent's Signature of No Florida Date �`w"'°ate, D. A CLARK +* MY COMMISSION I FF 2M08 le EXPIRES: ,tune 27, 2019 ?O ndw Bmded Thro Bud9el NotaryStWM Contractor/Agent is YES Personally Known to Me or Produced 1D NIA Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building 1311" Electrical E3*"' Mechanical E� Plumbing Gas❑ Roof ❑ Construction Type: ./C3 Total Sq Ft of Bldg: 3 6 3 3 Occupancy Use: 2'3 Flood Zone: X-5CE AiTA ffro Min. Occupancy Load: 14 # of Stories: 7— New New Construction: Electric - # of Amps ZOO Fire Sprinkler Permit: Yes ❑ No E� # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: VN CC. 10-11_* FIRE: Plumbing - # of Fixtures 7-"A Fire Alarm Permit: Yes ❑ Nci]� WASTE WATER: COMMENTS: Ok to construct single family home with setbacks shown. Revised: June 30, 2015 BUILDING: SI- 114 "/` Permit Application a • t r� = dY: CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: / � f A (-0 y (O Documented Construction Value: $ �_IMAOy JobAddress: —qOMar 604 -le Parcel ID: 21-19-30-5TT -0000-00- 0 Historic District: Yes ❑ No 9 Residential Q Commercial ❑ Type of Work: New O Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Plan Review Contact Person: Daphne Clark Title: Phone: 407-257-6940 Fax: ..,11-n-- 11 V=1 -- 11 Property Owner Information Name TAYLOR MORRISON OF FLORIDA INC Phone: 407-629-0077 Street: 151 SOUTHHALL LANE # 200 Resident of property? City, State Zip: MAITLAND FL 32751 Contractor Information _- ____Name_JOHN ASA WRIGHT / TAYLOR MORRISON OF FLORIDA____ -Phone: 407-257-6940 Street: 151 SOUTHHALL LANE # 200 City, State Zip: Name: Street: City, St, Zip: _ MAITLAND FL 32751 Bonding Company: N/A Address: Fax: State License No.: CBC1257462 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: N/A Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51D Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. lAlu Signature Or Owner/Agent Efate TAYLOR MORRISON OF FLORIDA INC Print Owner/Agent'sN e Signature of -State of Florida batil „Ar vv D.A. CLARK MY COMMISSION I FF 209108 ' * EXPIRES: June 27019 P�'"eorFw d�°e gondedlDruSudgelNobry sew u+ Owner/Agent is YFS personally Known to Me or _ Produced ID _ N/A - 'Type of ID _ Signature ontractor/Agent oelv Date JOHN ASA WRIGHT Print Contractor/Agent's Signature of No Florida Date �''�'`•'.°���D. A CLARK * * MY COMMISSION I FF209108 EXPIRES: June 27, 2019 eofnd� r k*d1ANBudgelMobrysemm Contractor/Agent is YES Personally_ Known to Me_ or Produced ID 1 o11A Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof ❑ Construction Type: Occupancy Use: Total Sq Ft of Bldg: Mn. Occupancy Load: Flood Zone: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Fire Alarm Permit: Yes ❑ No ❑ UTILITIES:61t'S•/,L WASTE WATER: 1213:4 BUILDING: Revised: June 30, 2015 Permit Application It SUBDIVISION: 1:100 r0ke_ LOT #: CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: S loo_ } Job Address: 3EQ Rezz( ko-9 La nr Historic District: Yes ❑ No ❑ Parcel ID, fhornbrwLl #3 - I 42bt'ht," S Residential g Commercial ❑ Type of Work: New E9 Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: NEW RESIDENTIAL PLUMBING Plan Review Contact Person: Title: Phone: Fax: Email: Property Owner Information Name vv- mom SD Phone: Street: Resident of property? City, State Zip: Contractor Information Name NORTHWEST PLUMBING OF ORLANDO Phone: (770) 941-5421 x 2082 Street: 6310 MABLETON PARKWAY, SUITE 1000 Fax: (770) 941-9522 City, State Zip: MABLETON, GA 30126 State License No.: CFC1426562 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARDING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction I understand that a separate permit must he secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, healers, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the dale of application and the code in effect as of that date: 5i° Edition (2014) Florida Building Code Rcvi.wd: June 30. 2015 Permit Application NOTICE-: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public: records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notily the owner of the property of the requirements of Florida Lien Lair, FS 713. The City of Sanford requires payment of a plan review fee at the time ol'permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value ol'the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: 1 certify flint all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. l Signature of Owner/Agent Dale Signature of r tractor/Agent Date Print Owner/Agcnl's Name Print Contr ctor/Agent's dame To" e 9� ' Signatwe of Notary -State of Florida Date _ ```%tttt-ttLA%, g4Wjure of Nota State of Florida Dat I _ � S Owner/Agent is Personally Known to Me or Q AVG ?t: GLbn ae€or/Agent is � Personally Known to Me or Produced ID Type of ID ' �C ICS r du d ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: - Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: lteviscd. June :50, 2013 Permit Application I �f 1 I , CITY OF SANFORD BUILDING & FIRE PREVENTION ' PERMIT APPLICATION Application No: = Documented Construction Value: S Job Address: Historic Historic District: Yes ❑ No,K Parcel ID: Residential, Commercial ❑ Type of Work: New�q Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move Description of Work: 1`Q► ccJ KoL....A ; r- i n _ .9-�r�1 r•� O AJ__y_x.l c9U Plan Review Contact Person: Title: Phone: y 0'2�1 Fax: L.I 01 $ I R, :] 1-7 1 Email: C J Property Owner Information Name_6_4A-Wbrri_�,ss n-WpnNQ� Phone: 40'i coA9 —bo 71'7 Street: Q(c go [IA Cj ¢,an_4)�c SL _ ;5gw Resident of property? _&O City; State Zip:,XYlo.�-Horrl R_ 3a -I51 Contractor Information Name ,A c_1 Io_ , El e__cA1g�i c.al`� ;cam Phone: t-IC7"1 $I 2t -oda a Street: a I t> Fax: 4CY0 City, State Zip: "Or'l a:�,,d a State License No::. —0-0000 5014_ Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE•TO•RECORD A NOTICE.QF COMMENCEiNENT MAX RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT kUST' E& REC6k6ED ANO POSTED ON THE 30111 SITE -BEFORE TAE FIRST INSPECTION. IF YOU INTEND TO' OBTAIN FINANCING, CONSULT WITR 'YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as'indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of thatdate: S"' Edition (2014) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current TCC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating• construction and zoning. Signature of Owner/Agent Date SignatureM ctodAgent Dat � e Print OwncdAgent's Name ,?ri9 Qo.plj;ctort►geA1's Name n; tEN HUGHES r•wr1 Signature, OfNotaTrstate of Florida Date. �r >ta1 t ru 11QliiQ� Mar 76, 201 a CO 7 ' ion # FF 002174 ihrouflh Natiossn nal Notar Y A. Owner/Agent is Personally Known to Me or Contractor/Agent is personally Known to Me or Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical Mechanical ❑ Plumbing[] Gas[3 Roof 11 Construction Type: Occupancy Use: , Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load:. N of Stories: .. New Construction: Electric - # of Amps _ Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No [ - APPROVALS: ZONING: - -- •UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: SCPA Parcel View: 21-19-30-57T 0000-0030 http://parceidetai I.scpafl.org/Parcel Detail lnfo.aspx?PLD=2119305TTO... Property Record Card 0.11 P� Panel: 21 -19 -30 -STT -0000-0030 Owner. TAYLOR MORRISON OF FL INC ocwasoournv rav+ox Property Address: 380 RED ROSE LN SANFORD, FL 32771 Parcel Information I ' Value Summary j Tax Amount without SOH: $8$5.29 2015 Tax Bill Amount $885.29 Tax Estimator Save Our Homes Savings: $0.00 TRIM Notice Help Does NOT INCLUDE Non Ad Valorem Assessments Legal Description + LOT ' —� THORNBROOKE PHASE 1 LPB 799 PGS 3 TO 7 Taxes j I Taxing Authority 2016 Working Taxable Value 2015 Certified County Bonds Values s0 ; Values Valuation Method CostfMarket CosllMarket Number of Buildings } 0 - ; 0 - - Depreciated Bldg Value i - - - - $47,8501 $0 i Depreciated EXFT Value City Sanford -- - - - - - - - -- -=-- - - - --- - -- - - -- Land Value (Market) $50,925 ~ $43,500 $0 Y $50.925 + Land Value All Just/Market Value " -- $50,925 $43,500 - Ponability Adj - -- -} - - - -- - - - - - - - - Save Our Homes Adj r s0 1 s0 Amendment 1 Adj $3,075 $0 1$0 P&G Adj s0 Assessed Value $47,850 $43,500 Tax Amount without SOH: $8$5.29 2015 Tax Bill Amount $885.29 Tax Estimator Save Our Homes Savings: $0.00 TRIM Notice Help Does NOT INCLUDE Non Ad Valorem Assessments Legal Description + LOT ' —� THORNBROOKE PHASE 1 LPB 799 PGS 3 TO 7 Taxes j I Taxing Authority Assessment Value Exempt Values Taxable Value County Bonds $47,850 1 s0 ; $47,850 1 SJWM(Saint Johns Water Management) j $47,850 I s0 ' $47,850 County General Fund - - - - - - i - - - - $47,8501 $0 i $47,850 City Sanford $47,850 s0 $47,850 Schools $50,925 $0 Y $50.925 + Sales Description Date Book Page Amount Qualified Vac/Imp No Sales Find Comparable Sales Land Method Frontag. Depth Units Units Price Land Value LOT I 1 + $48,500.00 ; $50,925 Building Information - Permits - - - - - - - - - - j- Permit a Description Agency Amount CO Date Permit Date 1 of 2 �� 10/4/2016 7:06 AM A 0 0 0 Application for Right -of -Way Use ' for Driveway, Walkway & Landscape iO R I D,9 Department of Planning & Development Services —1877 300 North Park Avenue, Sanford, Florida 32771 www.a.MoNn.yov Phone: 407.688.5140 Fax: 407.688.5141 This permit authorizes work to be done in the City of Sanford's right-of-way in accordance with the City's regulations and the e attached construction plans approved as part of this permit. It does not approve any work within any other jurisdiction's right-of-way. All requested information below as well as a current survey, site plan or plat clearly identifying the size and location of the existing right-of-way and use shell be provided or application could be delayed. po"Badw Call-ttae..rew selohls I. 1. Project Location/Address: 2. Proposed Activity: Vr Driveway ❑ Walkway M Other: 3. Schedule of Work: Start Date cC�oompletion Date � Emergency Repairs �'^ 4. Brief Description of Work: I �C $VA Y Me AI�.J W A This application is submi er a �/ p �/npp�/ `[,yy Signature: � Print Name: AY14f. f ,M OW fibJ1�95 Address: 44A)M/MWO R.. I Phone: wr - Ny 14 0 Fax- olcrahneC_ A&rm W�i/�MOXAV Date: Maintenance Responsibilities/Indemnification The Requestor, and his successors and assigns, shall be responsible for perpetual maintenance of the improvement installed under this Agreement This shall include maintenance of the Improvement and unpaved portion of right-of-way adjacent thereto. Requestor may, with written City authorization, remove said installationlimprovement fully restoring the right-of-way to its previous condition. In the event that any future construction of roadways, utilities. stornwater facilities, or any general maintenance activities by the City becomes in conflict with the above permitted activity, the permittee shall remove, relocate and/or repair as necessary at no cost to the City of Sanford insofar as such facilities are in the public right-of-way. If the Requestor does not continuously maintain the improve- ment and area in accordance with previously stated criteria, or completely restore the right-of-way to its previous condition, the City shall, after appropriate notice, restore the area to its previous condition at the Requestor s expense and. If necessary, file a lien on the Requestoes property to reoover costs of restorallon. To the fullest extent permitted by law, Requestor agrees to defend, indemnify, and hold harmless the City, its aouncilpersons, agents, servants, or employees (appointed, elected, or hired) from and against any and all liabilities, claims, penalties, demands, suits, judgments, losses, expenses, damages (direct Indirect or consequential), or Injury of any nature whatsoever to person or property, and the costs and expenses incident thereto (including costs of defense, settlernerrL and reasonable attorneys fees up to and including an appeal), resulting in any fashion horn or arising directly or indirectly out of or connected with the use of the Chys right-of-way. I have read an understand the above statement and by signing this application I agree to its terms. I hereby understand an to pay all city fees related to this application as required by the city's adopted Fee Resolution. Signature: Date: iA4� This permit shall be posted on the site during construction. ' Please call 407.688.5080, Ext. 540124 hours in advance to schedule a pre -pour inspection. Pre -pour Inspection by: Date: SOPIOM r 2010 ROW Use Driveway.pdf V. • DESCRIPTION AS FURNISHED: Lot 3, THORNBROOKE PHASE 1, as recorded in Plot Book 79, Pages 3 thru 7, Public Records of Seminole County, Florida. BOUNDARY FOR/CERTIFIED TO: Anthony A. & Tiffany H. Borresi; Inspired Title Services, LLC; First American Title insurance Company; Taylor Morrison Home Mortgage REC. 1/Y I.R. i ` O�P�S - - NO I.D. 10 CU JO5 A O'A\X61 Nal ON 100N d l8gl PVC FENCE 3,g o ReL a_V bl, 0.2' LOT gge N REG. 1/2' I.R. NO I.D. .ff . /tiM .1 65.62' 45.81' Ti CURVE DATA 3.0'x3.0' Go ti'p titi' R=100.00' Gyo N OTA U AC PADS 107 - 11,278 SOFT. L=40.16' LIVING a 1,453 RED ROSE LANE SOFT. C=39.89' 20.98' p 40.0 c 16.53 CV Ca=N 27.24'50" E LANAI - 400 o; COV'D. CONC. O; O ; LOT 2 SOFT. 18.87' 40.0 75.05' T. A/C PAD - 25 SO.FT. WALKWAY - 72 V. IMPERVIOUS= 26.4 R - 2,978 SQ.FT. SOD 7 SOFT. /,';�% -7 TWO STORY R 11I .0- APRON e RESIDENCE CE PROPOSED FINISHED SPOT GRADE ELEVATION SIDEWALK - 196 W O PER DRAINAGE PLANS "� F.1!825.20' SOFT. -= PROPOSED DRAINAGE FLOW � V\ SO.FT. LOT GRADING TYPE A SIDE - 5.0' BASED ON SUPPLIED PLAN DRIVEWAY - 518 SOFT. LOT 4 110 Iv SIDE CORNER - 10' AND/OR INSTRUC77ONS PER SIDEWALK - 268 o CLIENT NOT FIELD VERIFIED I S00 SOFT. GRUSIL'NML'YL'R-SCOTT EX• ASSOC, INC. - LAND SURVEYORS ' . 5400 E. COLONIAL DR. ORLANDO. FL. 32807 (407)-277-3232 FAX (407)-658-1436 PF : rPLAT im ; POINT ON LINE NNares: 18. 1. INE UNDOLSIGNED DOES HEREBY CERRFY THAT THIS SURVEY MEETS TINE MNAI M IECND9CAL STAND SET FORM BY 10.37' o COV'D. . LA. • 1/2• IR ./0.t 45x NA • NO* -RAMAL SE. 2. UNLESS EMBOSSED MM SURVEYOR*$ SIAL THIS SURVEY IS NOT VAUD AND IS PRESENTED, FOR INFORK47001 PURPOSES ONLY POINT PO�CL:�PWPOINT C CALTED 3. THIS SURVEY WAS PREPARED FROM TITLE INBIIS E INFORMATION FHED TO THE SURVEYOR. THERE MAY BE OTHER RESTRICITDM od BRICK PERNT RCFEItOCC H AMOR R POR. . POINT Or 00063ROALNT PAR NOI OR CASEMI MS THAT AFFECT DO PROPERTY.E CENIELLLDc rr. : FDNSWD FLOOR ELEVATION 4. NO UNDEROROUND WPROVQLEMS NAVE BEEN LOCATED UNLESS OTHIRM E SHOWN. WD • MAIL 6 DISK LTJL MOLDING SET9AVL LINE 5. THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT Or DIOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHER 01117Y. RR/VEAi VAY RX MM MT.DRAIN 6, OWENSI NS "AN FDP THE LOCATION OF IMPROVEMENTS NIXON SHOULD NOT BE USED TO REOONSIRUC7 9"wY ONES. 8.49' . DRAINAW 7. "UM. ARE BASED ASSUMED DATUM AND ON INC UNE SHOWN AS BASE BEi1RINO (B•&) C4 UTIL. • UTLITT A ELEVATIONS, 1F SHOWN, ARE 84SED ON NATIONAL GEODETIC YOVI AL DATUM OF 1920, UNLESS OTHERWISE NOTED. arc . VAItNE N LIFENCE VOFC • 04AI F w BRICK WALK C/D • CONCRETE KDCK SCALE I� ►' JO'-� DRAWN BY: ••• P.C. POINT OF CI6IVATWE P.T. • POINT K TANQICY DESC, DESCRIPTION CERTIFIED BY. DATE ORDER NO. R• RADIUS L -22-Q 6_' 1 � 5.51' : �TNL,[NGTN REVISED SO. FT. CALCS. 10-18-16 C • CHORD • Cl CH MD KARING BRICK NORTH FlNAL/ELEVS. 04-21-17 1625-17 M 25.38DR. 24.13' 7N75 BUILDINC/PROPERTI' DOES. NOT UE WITHIN� THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER 'FIRM' NGRUSEN R.LS. / 4714 ZONE X. AAP / 12117C 0055 F. S W. SCOTT, R.LS 1 4801 10 L. ESMT. 11' 1h .aJ ryti• i C' L�2i20 REC. 1/2' I.R. d REC 1/2' I.R. 0.2' 5' CONC. p p NO I.D. (PC) NO I.D. OFF WALK CURVE DATA C1=D=23.00 33 Go ti'p titi' R=100.00' Gyo N OTA U T s: 107 - 11,278 SOFT. L=40.16' LIVING a 1,453 RED ROSE LANE SOFT. C=39.89' GARAGE - 477 SOFT. ENTRY - 144 (50' R/W) TRACT I SQ.FT. Ca=N 27.24'50" E LANAI - 400 SOFT. BREEZEWAY -NIA SOFT. DRIVEWAY - 407 SO.FT. A/C PAD - 25 SO.FT. WALKWAY - 72 SOFT. IMPERVIOUS= 26.4 R - 2,978 SQ.FT. SOD 7 SOFT. /,';�% OFF LOT AREA CALCULATION R 11I APRON SOFT. PROPOSED FINISHED SPOT GRADE ELEVATION SIDEWALK - 196 SO. FT. PER DRAINAGE PLANS BUILDING SETBACKS: SOD- 10 SOFT. -= PROPOSED DRAINAGE FLOW FRONT a PROPOSED INFORMATION SHOWN AREA - 11,695 REAR 155'' - SO.FT. LOT GRADING TYPE A SIDE - 5.0' BASED ON SUPPLIED PLAN DRIVEWAY - 518 SOFT. PROPOSED F.F. PER PLANS - 25.1' SIDE CORNER - 10' AND/OR INSTRUC77ONS PER SIDEWALK - 268 SOFT. CLIENT NOT FIELD VERIFIED I S00 SOFT. GRUSIL'NML'YL'R-SCOTT EX• ASSOC, INC. - LAND SURVEYORS LEGEND - LEGEND - . 5400 E. COLONIAL DR. ORLANDO. FL. 32807 (407)-277-3232 FAX (407)-658-1436 PF : rPLAT im ; POINT ON LINE NNares: IP. . am PIC PAC • POINT ar NEVERSL CURVATUMK IR •MOI RDD PCG • PDDR v' COMPOUND VRVATURC 1. INE UNDOLSIGNED DOES HEREBY CERRFY THAT THIS SURVEY MEETS TINE MNAI M IECND9CAL STAND SET FORM BY • CONCRETE NONI/QNT RA• RADIAL INE FLORIDA 8040 OF PROFESSIONAL HAND SURVEYORS 9N CHAPTER &1-17 OF INE FLORIDA ADMINISTRATIVE CODE. . LA. • 1/2• IR ./0.t 45x NA • NO* -RAMAL SE. 2. UNLESS EMBOSSED MM SURVEYOR*$ SIAL THIS SURVEY IS NOT VAUD AND IS PRESENTED, FOR INFORK47001 PURPOSES ONLY POINT PO�CL:�PWPOINT C CALTED 3. THIS SURVEY WAS PREPARED FROM TITLE INBIIS E INFORMATION FHED TO THE SURVEYOR. THERE MAY BE OTHER RESTRICITDM PERNT RCFEItOCC H AMOR R POR. . POINT Or 00063ROALNT PAR NOI OR CASEMI MS THAT AFFECT DO PROPERTY.E CENIELLLDc rr. : FDNSWD FLOOR ELEVATION 4. NO UNDEROROUND WPROVQLEMS NAVE BEEN LOCATED UNLESS OTHIRM E SHOWN. WD • MAIL 6 DISK LTJL MOLDING SET9AVL LINE 5. THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT Or DIOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHER 01117Y. RR/VEAi VAY RX MM MT.DRAIN 6, OWENSI NS "AN FDP THE LOCATION OF IMPROVEMENTS NIXON SHOULD NOT BE USED TO REOONSIRUC7 9"wY ONES. . DRAINAW 7. "UM. ARE BASED ASSUMED DATUM AND ON INC UNE SHOWN AS BASE BEi1RINO (B•&) UTIL. • UTLITT A ELEVATIONS, 1F SHOWN, ARE 84SED ON NATIONAL GEODETIC YOVI AL DATUM OF 1920, UNLESS OTHERWISE NOTED. arc . VAItNE N LIFENCE VOFC • 04AI F w 9. CERIrLGTr OF AUTHORIZATION w. 4596. C/D • CONCRETE KDCK SCALE I� ►' JO'-� DRAWN BY: ••• P.C. POINT OF CI6IVATWE P.T. • POINT K TANQICY DESC, DESCRIPTION CERTIFIED BY. DATE ORDER NO. R• RADIUS L PLOT PLAN 09-15-18 3167-16 : �TNL,[NGTN REVISED SO. FT. CALCS. 10-18-16 C • CHORD • Cl CH MD KARING FORMBOARD FOUNDATION/ELEVS. t1 -?I -IB 3913-18 , NORTH FlNAL/ELEVS. 04-21-17 1625-17 M 7N75 BUILDINC/PROPERTI' DOES. NOT UE WITHIN� THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER 'FIRM' NGRUSEN R.LS. / 4714 ZONE X. AAP / 12117C 0055 F. S W. SCOTT, R.LS 1 4801 Parcel ID Number: 21-19-30- 5TT -0000-003 0 Prepared By Kim Carter and Taylor Morrison Homes Return To : 2600 Lake Lucien Drive, Suite 350 Maitland, FL 32751 NOTICE OF COMMENCEMENT. State of Florida. County of Seminole. 111111111111111111111111111111111 fill Ili 1 11ARYANNE MORSEr SEMINOLE COUNTY CLERK OF CIRCUIT COURT & COMPTROLLER BY. 8780 P9 501 (1P9s) CLERK'S Y 2016103950 RECORDED 10/04/2016 02:144.2 PI1 RECOWING FEES $10.00 RECORDED BY hdev-we The undersigned hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. I . Description of property : LOT 3 Legal Description : Thornbrooke Phase 1, according to the plat thereof, as recorded in Plat Book 79, Page 3-7, of th ublic records of Seminole County, FI i Addresses : l% Sanford FL 2. General description of improvements : Single Family Home 3. Owner information : Name Taylor Morrison of Florida Inc. Address 2600 Lake Lucien Drive Suite 350, Maitland, FL 32751 4. Fee Simple Title Holder: N.A. 5. Contractor name and address : Name Taylor Morrison of Florida Inc. Address 2600 Lake Lucien Drive Suite 350, Maitland, FL 32751 6. Surety: N.A. 7. Lender: N.A. 8. Persons within the State of Florida designated by the Owner upon whom notices or other documents may be served as provides by 713.13(1)(a)7., Florida Statutes: N.A. 9. In addition to himself, Owner designates the following to receive a copy of the Lienor's Notice as provided in 713.13(1)(b), Florida Statutes. N.A. 10. Expiration date of notice of commencement: One year from the date of recording. WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTENT TO OBTAIN FINANCING, CONSULT YOUR LENDER OT ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. 11. Date Signed : Signature of Owner's Agent Jo Asa Wright Taylor Morrison of Florid. Sworn to and subscribed before me this by John Asa Wright who is personally known to me. Notary Public DA Clark My commission expires: 6/27/19 O�7 0 �rial No.201 c FF 209108 oUBLIC No nature: - AND- 1% d/ATEA +! �.T4 Verification pursua *dtio` eeti.pn',g2.525, Florida Statutes. Under penalties of perjury, I declare that 1 have read the +. . WOK ft,egdf3igr6n!Fhat tjFe.facts stated'in it are true to the best of my knowledge and belief. IRCUIT URTAl D d RIDA ,t��'t���w•`I'•t� DEPUTY CLERK COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 16100005 BUILDING APPLICATION #: 16-10000563 BUILDING PERMIT NUMBER: 16-10000563 DATE: October 13, 2016 3(°33o UNIT ADDRESS: RED ROSE LN 380 21 -19 -30 -STT -0000-0030 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: Single Family SUBDIVISION: 705.00 TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: N/A Housing .00 ADDRESS: dwl unit APPLICANT NAME: TAYLOR MORRISON OF FL. INC. FIREnRESCUEmily R ADDRESS: 151 SOUTHHALL LN., #20b MAITLAND FL 32751 LAND USE: SFR TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 380 RED ROSE LN / LOT 3 / SFR CO -WIDE ORD THORNBROOKE PH 1 -------------------------------------------------------------------------------- FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE -------------------------------------------------------------------------------- UNITS TYPE ROADS-ARTERIALS CO -WIDE ORD Single Family Housing 705.00 1.000 dwl unit 705.00 ROADS -COLLECTORS N/A Housing .00 1.000 dwl unit .00 FIREnRESCUEmily R .00 LIBRARY CO -WIDE ORD Single Family Housinc{ 54.00 1.000 dwl unit 54.00 SCHOOLS SSingle Family CO -WIDE ORD Hou7iing 5,000.00 1.000 dwl unit 51000.00 PARKS .00 LAW ENFORCE N/A .00 DRAINAGE N/A .00 AMOUNT DUE 5,759.00 STATEMENT �jQ RECEIVED BY T' f'$4^ VN\' SIGNATURE : (PLEASE PRINT NAME) DATE: Lt•IC) NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1 -BLDG DEPT 3 -APPLICANT 2 -FINANCE 4 -LAND MANAGEMENT **NOTE** v•�W PERSONS ARE ADVISED THAT TI{IS IS A STATEMENT OF FEES DUE UNDER THE 1 SEMINOLE COUNTY ROAD, FIR] HSCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. \�• PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THS REQUEST FOR REVIEW MUST MEET THE RE UIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES OVERNING APPEALS MAY BE PICKED UP OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDERAND SHOULD REFERENCE L THE COUNTY BUILDING PERMIT NUMBER AT THE '1OP LEFT OF THIS STATEMENT. ***THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE * DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. City of Sanford Building and Fire Prevention Division D 300 N. Park Ave Sanford, FL 32772 2016 Residential Permit Fee Calculation Form Effective February 2016 - August 2016 BP# 16-2686 380 Red Rose Lane Type of Construction: I VB SQUARE FOOTAGE OF RESIDENCE LESS GARAGE: SQUARE FOOTAGE OF GARAGE ONLY: Lot 3 3156 s uare feet 477 s uare feet SQUARE FOOTAGE OF GARAGE AND RESIDENCE: 3633 square feet Dollar Valuation of Work: $376,811.91 State Fee: Permit Fee Application Fee: Plan Review Fee: Total Building Permit Fees: $114.99 $2,677.68 $25.00 $1,130.44 $3,948.11 Plumbing Fixture Calculation 16-2686 380 Red Rose Lane Lot 3 Bath Tubs 3 Sinks 1 Drinking Fountain Solar Piping Disposal 1 Soda Fountain Dishwasher 1 Urinals Floor Drain Vacuum Breakers 1 Sewer Connection 1 Washing Machines 1 Ice Maker 1 Water Closets 4 Laundry Tubs 1 Water Heaters 1 Lavatories 5 Water Piping 1 Pool Piping Water Softener Showers 2 Total Plumbing Fixtures - 24 Permit #: 16-2686 Address: 380 Red Rose Lane Lot 3 Structure Information Construction Type: VB Occupancy Type: R3 Roof Type: Shingle Flood Zone: None Number of Stories: 2 Number of Bathrooms: 3.5 Square Footage: 3633 Plumbing Fixtures: 24 Fire Sprinkler System: No Fire Alarm: No Occupant Load: 19 REQUIRED INSPECTION SEQUENCE TAYLOR MORRISON SFR -DETACHED Permit # 16-2686 Address: 380 Red Rose Lane Lot 3 BUILDING PERMIT Min Max Inspection Description 10 10 Form board / Foundation Survey 10 Temporary Underground Power (TUG) Slab / Mono Slab Pre our 20 1000 Lintel / Tie Beam / Fill / Down Cell 30 Sheathing — Walls 30 Sheathing — Roof 30 50 Final Window 40 Roof Dry In 50 Frame 60 Insulation Rough In 70 Drywall / Sheetrock 40 70 Lath Inspection 50 1000 Final Roof 50 1000 Final Stucco / Siding 80 1000 Insulation Final 1000 Final Single Family Residence REVISED: June 2014 ELECTRICAL PERMIT Min Max Inspection Description 10 Plumbing Under ound 10 Footer / Slab Steel Bond 20 30 Temporary Underground Power (TUG) 30 Electric Rough 1000 Electric Final MECHANICAL PERMIT Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final Min Max Inspection Description 10 Plumbing Under ound 20 Plumbing Tubset 10 1000 Plumbing Sewer 1000 Plumbing Final MECHANICAL PERMIT Min Max Inspection Description 10 Mechanical Rough 1000 Mechanical Final � 8 b City of Sanford Planning and Development Services Engineering — Floodplain Management Flood Zone Determination Request Form Name: John Asa Wright Firm: Taylor Morrison of Florida, Inc. Address: 2600 Lake Lucien Drive City: Maitland State: Florida Zip Code: 32751 Phone: 407-257-6940 Fax: Email: daphne@permitspermitspermits.com Property Address: 380 Red Rose Lane Property Owner: Taylor Morrison of Florida, Inc. Parcel identification Number: 21-19-30-5TT-0000-0030 Phone Number: 407-629-0077 Email: The reason for the flood plain determination is: M New structure ❑ Existing Structure (pre -2007 FIRM adoption) ❑ Expansion/Addition ❑ Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4360) OFFICIAL USE ONLY Flood Zone: x Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0055 F Map Date: September 28, 2007 The referenced Flood Insurance Rate Map indicates the following: ❑ The parcel is in the: ❑ floodplain ❑floodway ❑ A portion of the parcel is in the: ❑ floodplain ❑ floodway ❑■ The parcel is not in the: N floodplain ❑ floodway ❑ The structure is in the: ❑ floodplain ❑ floodway ❑ The structure is not in the: ❑ floodplain ❑ floodway If the subject property is determined to be flood zone `A', the best available information used to determine the base flood elevation is: BP# 16-2686 Reviewed by: Michael Cash, CFM Date: October 17, 2016 DESCRIPTION AS FURNISHED: Lot 3, THORNBROOKE PHASE 1, as recorded in Plat Book 79, Pages 3 thru 7, Public Records of Seminole County, Florida. PLOT PLAN FOR/CERTIFIED TO: Taylor Morrison of Florida, Inc. LOT 4 RECORD COPY G°3"YOW �a 1i 0'S MT-pp,G „ 1pg000 0 00 \ LOT 3 64.75' 44.94' `J1 o AC P' .) 221pCOV'40.0 D. PATIO 18.87' 40.0 'Z W O Jr- CTA � N 10.37' 8.49' PROPOSED RESIDENCE MODEL: DAPHENE 111-9 2 CAR GARAGE RIGHT b ENTRY i� C4 PAVER ' DRIVE 10IL. ESMT. �j 16.70' 15.05' 5.51 Cv O � LOT 2 Q p I(. - 2(a8(Q _ OVED. PANS Ok to construct single family home with setbacks shown. Zp'�-)b-- c 1 5' CONE. WALK 628 Cu B CURVE DATA POSSIBLE C1=D=23°00 33 DRAIN INLET AS R= 100.00' SCALED FROM ON LOT AREA CALCULATIONS. DRAINAGE PLANS LOT -11,278 SOFT. L=40.16' RED ROSE LANE LIVING = 1,453 SO.FT. C=39.89' GARAGE - 477 SOFT. (50' R/W) TRACT I ENTRY - 144 SO.FT. CB=N 27°24'50" E LANAI - 400 SQ.FT. BREEZEWAY -NIA SO.FT. DRIVEWAY - 407 SOFT. A/C PAD = 25 SO.FT. WALKWAY = 72 SOFT. IMPERVIOUS= 26.4 Z %79 SOFT. LOT A LC LA IONS: QQ� APRON - III SOFT. PROPOSED - FINISHED SPOT GRADE ELEVATION *PLOT PLAN ONLY" SIDEWALK - 196 SO. FT. PER DRAINAGE PLANS BUILDING SETBACKS: (NOT A SURVEY) SOD 110 SO.FT. PROPOSED DRAINAGE FLOW FRONT = 25' REAR 15' PROPOSED INFORMATION SHOWN AREA - 11.695 SOFT. LOT GRADING TYPE A SIDE - 5.0' BASED ON SUPPLIED PLAN DRIVEWAY - 518 SOFT, PROPOSED F.F. PER PLANS = 25.1' SIDE CORNER - 10' AND/OR INSTRUCTIONS PER SIDEWALK - 268 SOFT. CLIENT NOT FIELD VERIFIED SOD SO.FT. CRUSEYVNEYER-SCOTT & ASSOC, INC. - LAND SURVEYORS LEGEND - LEGEND - 5400 E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 P • PLAT PDL. • POINT ON LILAC r • r1ELD TTP. • TYPICAL ICAL NOT NP. • IROM PIPE PAL • POIMY Or REVERS[ CURVATURE IA. IRMROD P.CL • PDIM OF COMPOUND CURVATURE 1. THE UNOERSfGNED DOES HEREBY CERTIFY THAT THIS SURVEY MEETS THE MINIMUM TECHNCAL STANOAI SET FORM BY C.M. CONCRETE MONUMENT RAD. • RADIAL THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS W CHAPTER $J-17 OF THE FLORIDA AMNb7RA/NE CODE. SET I.R. . 12' IR •/0.B 4591 MR. • NON -RAMAL 2 UNLESS EMBOSSED WITH SURVEYOR'S SEAL. THUS SURVEY IS NOT VALID AND K PRESENTED FOR INFORMATIONAL PURPOSES ONLY. REC. . R[COVER[D VP. VITHESS POOR P.o.O. . Po1W1 Or BCGOMING CALL • CALCULATED ,7, THIS SURVEY WAS PREPARED rRWI TITLE INMRWRDN FURNISHED TO THE SURVEYOR. THERE MAY BE OTHER RESTRICTIONS P-01 • POINT OF COMMENCEMENT PAX • PERMANENT REFERENCE MONUMENT t CENTERLINE rF. • FTMISWD FLOOR ELEVATION OR EASEMENTS THAT AFFECT THIS PROPERTY. 4. NO UND ERGROUND WPROYEMENTS NAVE BEEN LOCATED UNLESS OTHERWISE SHOWN.MLD • NAIL t DISK RSL '• BUILDING SETBACK LINE R/V W RIGHT -OF -VAT INK • DCGVRK S. PUS SURVEY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIFIED TO AND SHOULD NOT BE RELIED UPON SY ANY OTHER ENTITY. ESMT. • CASEIEN7 R0. • )ASE BEARIW 6. DIMENSION! SWOWN MR THE LOCATION OF WPROVEMEMS HEREON SHOULD NOT BE USED TO RECONSTRUCT BOUMDARY, LINES. DRA10. . DRAINAGE 7. BEARINGS. ARE BUSED ASSUMCD DATUM AND ON THE UNE SHOWN AS BASE BEWNG (&1L) UTIL. • UTILI7Y 8 EIS%VONS, IF SHOWN. ARE BASLO ON NATIONAL GEODETIC VERTICAL DATUM Or 1029, UNLESS OTHERWISE NOTED. CLIC [NMN LINK iENCt • VDrG VOOD FENCE 0. Crr.71 ir.ATE W. AL?HORIZATION No. 4598. C/D • CONCRETE BLOCK SME T- I'••° 30 '-1 DRAWN BY: P.C. POINT OF CURVATURE P.T. • PO MT OF 7ANGENCT BES[. DESCRIPTION CERITnED T?Y: DATE ORDER No. _.__. P/RAD LCNGTN PLOT PLAN 09-15-18 3167-16 D • DELTA REVISED SO. FT. CALCS. 10-18-16 C • CHORD C.B. CHORD BEARING NORTH (' VAN t4 iH/5 BUILDING/PROPERTY DOES. NOT UE WITHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER nRM' GRUSE EYER. R.LS. /•4714 ' ZONE �(" MAP / 12117C 0055 F. JAMES W. SCO R.LS /4801 RECORD COPY p p iff4s T ELEckieQl EZVLCES6ffnc. 2153 Premier Row Orlando, FL 32809 407-812-1822 Fax 407-812-7171 LOAD CALCULATIONS ONE FAMILY DWELLING WITH HEAT PUMP HOME OWNER Taylor Morrison Homes HOUSE PLAN 2600 2 1 1 1 1 1 1 1 Daphene III #16-2686 SANFORD SQFT GENERAL LIGHTING X 3 VA PER SQ FT 20 AMP APPLIANCE CIRCUIT AT 1500 VA EA 3000 VA LAUNDRY CIRCUIT AT 1500 VA RANGE AT NAME PLATE RATING OR COOKTOP AND OVEN 8000 VA WATER HEATER 4500 VA DISHWASHER 1200 VA CLOTHES DRYER 5000 VA DISPOSAL (1/3 HP) 500 VA MICROWAVE/HOOD CIRCUIT 1500 VA NET GENERAL LOAD 19200 VA NET TOTAL HEAT 18020 VA TOTAL LOAD 37220 VA CALCULATED LOAD FOR SERVICE 37220 VA 1240 V= 155.08 ZOO AMP SERVICE AMP CCT -4201 �3�f: VA SUBTOTAL OF GENERAL LOAD 33000 VA FIRST 10 KVA OF GENERAL LOAD AT 100% 10000 VA REMAINDER OF GENERAL LOAD AT 40% 23000 VA x. 4 9200 VA TOTAL NET GENERAL LOAD 19200 VA 3 TON HEAT PUMP #1 24 AMP X 240 VA = 5760 VA 3 TON HEAT PUMP #1 24 AMP X 240 VA = 5760 VA TON HEAT PUMP #2 AMP X 240 VA = 0 VA 5 KW ELECTRIC HEAT AT 65% 3250 VA 5 KW ELECTRIC HEAT AT 65% 3250 VA KW ELECTRIC HEAT AT 65% 0 VA NET GENERAL LOAD 19200 VA NET TOTAL HEAT 18020 VA TOTAL LOAD 37220 VA CALCULATED LOAD FOR SERVICE 37220 VA 1240 V= 155.08 ZOO AMP SERVICE AMP CCT -4201 �3�f: a Mimi ■ ■ ■ T ■ ii■■■■■ ■tea MESSINESS 001101100101 EEXO ■Hti■H■i�L 3" WASTE STACK FW H i■■■wHt■■■■i ■■i 11wH ■■■■■■■■"WINE01010110 if■Hi■L!" ■■!■i'� i i H MEN ME ONE Up 102mom ■■maii■►m � i■�■ i��q►_ - ff�li �■ ■ ■I■w►row. -ice ■■■i�id■i�fii fit' ■t!. vHi�■i■■ t!Qi� EE -= -'TAYLOR MORRISON j- ---- -- THORNBROOKES.F. HOUSE TYPE: DAPHENE ; LOT 3 :`- 1ST FLOOR i 13 w I T -r I t I I TAYLOR MORRISON THORNBROOKE S.F. t lie! I HOUSE TYPE: DAPHENE LOT 3 2ND FLOOR ti 3" WASTE STACX FROM BATH 2 3" WASTE 5 --4 TERMINATING TO 1ST FLOOR I I TERMINATI �■�. m M mm ■ ■ m NMI �■■ TACK FROM BATH 3 MG TO 1ST FLOOR 7 -�- - ! Tlt M MUNIVERSAL yyorkorde eco: ctNo: 9253324-2008.0000 ENGINEERING SCIENCES R D 9/28/2016 eport ate. Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Construction Materials Testing • Threshold Inspection Building Inspection • Plan Review • Building Code Administration 3532 Maggie Blvd, Orlando, 32811 • P:407.423.0504 -F:407.42&3106 In -Place Density Test Report Client: Taylor Morrison of Florida, Incorporated 2600 Lake Lucien Drive Suite 350 _ Maitland, FL 32751 Project: Thombrooke 40s & 50s, SF House Lots Various Lots, Sanford, Seminole County, FL 32771 Area Tested: lot 176 Material: Fill Reference Datum: 0 = Top of Fill UES Technician: Shannon Comett Date Tested: 09/28/2016 Type of Test: Field: ASTM D-2937 Drive Cylinder Method Laboratory: ASTM D1557 Modred Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Test No. Location of Test Range aximum Density (pd) ptimum Moisture 1%) Field Dry Density (I)CF) Field Moisture (%) Soil Compaction 1%) Fill De p Depth (inch) Pass or Fail 6 NE comer of lot 176 0.1 ft 105.4 11.8 107.8 3.9 102 N/A Pas: 7 SE comer of lot 176 1_2 ft 105.4 11.8 109.7 4.3 104 N/A Pas: 8 NW comer of lot 176 1_2 ft 105.4 11.8 105.3 4.2 100 N/A Pas: 9 middle of lot 176 1.2 ft 105.4 11.8 106.4 3.7 101 N/A Pas: 10 middle of lot 176 2_3 ft 105.4 11.8 102.7 5.1 97 N/A Pas: Tn nnlnhliah � .n•.h.n/ n...M..Knn {n I In:..n...nPe ..I:nnle {hn Dnhl:.. n.a1 n.onnF•nn .�/l .nnnr{n .ins n..h.`.:Mn'1 nn ..nnFdnn{:.�/ n.n..nr{.• of n.o nl:nnM .�n'I n..Mnrr.nHnn EDUNIVERSAL 1N ES Pr erect o. 0110.1 01008.0000 ENGINEERING SCIENCES Report Date: 9/21/2016 Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Construction Materials Testing • Threshold Inspection Building Inspection • Plan Review • Building Code Administration ! 6 3532 Maggie Blvd, Orlando, 32811 • P: 407.423.0504 • F: 407.423.3106 I/ In -Place Density Test Report Client: Taylor Morrison of Florida, Incorporated U S.Technician: Alexis Reyes 2600 Lake Lucien Drive Suite 350 •- ' Maitland, FL 32751 -Rafe. Tested: 09/21/2016 Project: Thornbrooke 40s & 50s, SF House Lots Various Lots, Sanford, Seminole County, FL 32771 Area Tested: Lot 7 Material: Fill Reference Datum: 0 = Bottom of Footing Type of Test: Field: ASTM D-2937 Drive Cylinder Method Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Test No. Location of Test Range aximum Density (per ptimum Moisture 1%) Field D Dry Density (pcf) Field Moisture (%) Soil Compaction 1%1 Fill Depth (inch) pass or Fail 1 NE footing 0-1 ft 105.4 11.8 101.6 12.1 96 N/A Pas: 2 SW footing 1-2 ft 105.4 11.8 99.8 11.4 95 N/A Pas: '3 NW footing 1.2 ft 105.4 11.8 103.2 10.4 98 N/A Pas: 4 N corner of pad (TOF) 1-2 ft 105.4 11.8 102.5 12.2 97 N/A Pas: 5 Centerr of pad (TOF) 2-3 ft 105.4 11.8 101.2 10.9 96 N/A Pas: Remarks: TOF=Top of Fill Tn—#.WiM' a {n / Inb.eroePn -6-0n {he 0..1.1:.. -4 ro..re6.ee .11 — #n oro e.nh...iHed en i...nFilen{iel n.r —%' nl ^— nlien{n —8 e..{hnri�e{inn DESCRIP77ON AS FURNISHED: Lot 7, THORNBROOKE PHASE 1, as recorded in Plat Book 79, Pages 3 thru 7, Public Records of Seminole County, Florida. BOUNDARY FOR/CERTIFIED TO: Taylor Morrison of Florido, Inc. FLORIDA LAND do COLONIZATION COMPANY LIMITED W. BFAROSALL'S MAP OF ST. JOSEPHS (PLAT BOOK 1, PAGE 114) 0.4' S 00014'55" E 0.4• ON 50.00' ON r ti FENCE �A LOT 8 7 Ne o� ^ 00 29.80' LOT 7 5.00' -- 5.00' 5.00' 29.80' 7.5 220' 25.20' I 10' UTIL. ESMT. — (B.S.) S 00014'55" E 50.00' O RED ROSE LANE (50' R/W) TRACT I 5.00' 1 � O O O h d N R �y IT� A 00 5.00' LOT 6 (PC) p LVI = O,z:.7v z'IJ.P I. � LIANG = 2.055 SO. F7. Oe GARAGE - 460 SOFT Q� ENTRY a 46 SO.F7. powaLANAI - 176 SOFT. PROPOSED = FINISHED SPOT GRADE ELEVATION BREEZEWAY- N/A SO.FT. PCR DRAINAGE PLANS DRIVEWAY = 403 SOFT. --,- - PROPOSED DRAINAGE FLOW A/C PAD = 12 SO.FT. AREA - 6,800 SOFT WALKWAY = 37 SOFT. BASED ON SUPPLIED PLAN IMPERVIOUS= 510 x SIDE CORNER = 10' = 3 189 SO FT p SOD = 3 061 SOFT. A 1 N � Oe R/W = 550 SOFT. Q� APRON - 110 SO.FT SIDEWALK = 250 SOFT PROPOSED = FINISHED SPOT GRADE ELEVATION BUILDING SETBACKS: SOD 190 SOFT. PCR DRAINAGE PLANS FRONT = 25' - --,- - PROPOSED DRAINAGE FLOW REAR = 15' PROPOSED INFORMATION SHOWN AREA - 6,800 SOFT LOT GRADING TYPE A SIDE - 5.0' BASED ON SUPPLIED PLAN DRIVEWAY = 51,5 SO F7. SIDE CORNER = 10' AND/OR INSTRUCTIONS PER SIDEWALK - 287 SO F1 PROPOSED F.F. PER PLANS = 24.5' CLIENT NOT FIELD VERIFIED SOD = 3,251 SOFT. CRUSEMWEYLTR-SCOTT & ASSOC, INC. - LANA SURVEYORS LEGEND - LEGEND - 5400 E. COLONIAL DR. ORLANDO, FL. 32807 (407)-277-3232 FAX (407)-658-1436 P PLAr PaR. • PDINi oN LINO • 1ICL0TTP. • TYPICAL NOTES: 10. •IRON PIPE PRt POINT Of RCVERLC CURVATURE IR. •IRON RDD • POINT Of COFDIAID CURVATURE 1, THE UNDERSIGNED DOES HEREBY CERRFY THAT THIS SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS SR FORTH BY C.M. • CONCRETEIIQRINCNi RAD. RADIAL RAD. ME FLORIDA BOARD OF PROTESSWM LAND SURVEYORS IN CHAPTER lM-17 OF ME FLORIDA ADMINISTRATIVE CODE. SCT I.W. . I/Y 1R /OLD 4596 NR NON -RADIAL 2. UNLESS EMBOSSED WITH SURVEYORS SEAL, THIS SURVEY IS NOT VALID AND IS PRESENTED FOR INMRIAA710 M PURPOSES ONLY. RCC. • POINTRCCOr V.P. • VITNE$1 POOR PAD. •POINT Or BEGINNING CALL. • CALCULATED J. THIS SURVEY WAS PREPARED FROM TIME INFORMATION FURNISHED TO THE SURVEYOR. MERE LAY BE OTHER RESTRICTIONS Plot. • POINT OF CONNC1 Ewn ►RM • PERMANENT REFERENCE NOM/NCNT OR EASEMENTS THAT AFFECT THIS PROPERTY. I • CCHTCRLINC rf. • rIN1SNCD FLOOR ELEVATION 4. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED UNLESS OTHERWISE SHOWN. N►D NAIL L DISK tSL BUILDING SCTDACK LINC 5. THIS SURVEY IS PRETARED FOR THE SOLE evirm OF THOSE CERRF7ED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHER ENTRY. pr-vAr tJl BENCBASE DCRK P/v CASEMENT tJL • BASE tURINO 6. WMINSIONS SHOWN FOR THE 44. 77pN OF IMPROVEMENTS HEREON SHOULD NOT BE USED TO RECONSTRUCT SOUNOWY. LINES. naAiN. . DRAuIMAGC 7. BEARINGS, ARE BASED ASSUMED OATUV AND ON DTE UNE SHOWN AS BASE BEARING (MB.) UTIL. UTILITY Q CLEV4101S, IF ;MOWN, ARE 134SEO ON •SARONAL CEODERC VERTICAL DATUM OF 1999, UMISS OTHERWISE NOTED. CLfC. • CHAIN LIW. rCNCC vOrC v00D rENt[ 9. CERRRCATE OF AUTHORIZATION No. 4596. C/B • CONCRETE BLOCK SGILE V- 1' •• 20'� DRAWN BY: P.C. • PO "I Or CURVATURE P.T. • POINT or TMIGCHCY DESS. DESCRIPTION CERTIFIED HY. DATE OROER No. � .Tac LENGTH PLOT PLAN 06-08-16 1980-16 DDELLA FORMDOARD FOUNDATION/ELEVS. 09 -20 -IB 3207-I6 C • CICRD C 0, CHORD SCARING ' NORTH THIS BUILDING/PROPERTY DOES NOT UE WTTHIN THE ESTABUSHED 100 YEAR FLOOD PLANE AS PER FIRM' &SX. GRUSEN �R RL.S. � 4i14 ZONE X' LAP / 12117C 0055 F W. SCO R.L.S 1 4801 CD m CD F CU DCD 11 Ir Ir 11 ri a m -) m I xf411. n Iii 11 u II yj�Cm.1 �� �� � w�'a rr I I' O�l� C�.1� Ir �.!•1'��.0� ���'� ��.0���� � �a:0��1 v�_1� D V f11��1: J0 - - II I I Iljl - J05 T JO --- I ( I I P J06 ai m— � ..0 - _ � _ - J07 m - J0 i-00-00 s I I I _108 I 7 00 00 ---- JO - I HI I I — >08 J -A_ — 'L t— --Al—alt — — Jt —JL —lI— As. JL 0 1 a A I �— � FO / �I^. I� N A - - FO ►j F0 15-09-08 I 11-05- I FO It I F0 ! F0 Fe ' ^ 1 - �I F0 Fe _----- — F09°I -- I FO c F l I '� u FO FA -- 12 08-08 3-03-0 II i Ir- F0• FO — I; F0 I CD co M co nI2 2 2 ym Im I _ CD� m I - _ F6 170,- _ RO -- R01I- ROI RO I I I Hl — "T ° Q m i-- I=---- — I I j I _ I ; �I II{ Doli I T f ( ESS — - M RO — --- i ---- = - — -- -- -----I - _ II ' I I n g— o P I� I I 1 j„f d _ U to m R0 - �- N 1!-08-00 R9 - -- -- (D Re!—_ _= m 20- DEE? FLOOR TRUSSES 0 24• (� OC. FIELD ADJUST SPACING FOR — RO — — -- PLUMBING AND A/C CHASES RO — - -- R0 6 6 C IN RECORD COPY i -- fL M ? ? ? 7 ? 7 ? 7 7 :r ? J 7 J (1) (U ;o�;mmmmm�;m���m�mmmm �m� I u r. a u n u u u li o li 1 II II ! u 1 I n©- I CO (11 ; CO W "I 7 ; 7 CO 00 CO 28-04-00 II" OJ��DING SANFppD p1-PAR.�,. #16-2686 + •i OCT - 4 20'.rj ; BY. GEARING HEIGHT SCHEDULE rz//z/M 9.-q. 20'-3/4' 0 0 Hanger List H1 HTU26 H2 THA422 NOTES: t) REFER TO He 91(RECO WEFDATI" FOR HAIAD+6 INSTALLA*.ION AND 1 E..MIPOIZAAY D9AC11:5 ) REFER TO ENGINEERED DRAWIN(h FOA FERMrN'_4T DI:ACIM REOAREC. t) ALL TRU55E5 (61XLUDIR6 TRU55E5 Pak VALLEY FRAMM)-Ahi 9E U#4? E1ELY DECKED Or REFER T, 9 DtTAiI V1C9 FDI; ALTEINAIE DRAPING REAAREMENTS 3) ALL VALLEYS ARE T. DE (OWEATIO N I LY FRAM IY WIDER 4.) ALL TRUSSES AAF DE'.16NED rOR MAXIMII.I SPACING. I►AE55 OTHERWISE NOTED. 5) ALL WALLS SHOWN ON rLACF.EtiI PLAN ARE CONSIDERED TO DE LOAD DEARRNa LNE75 OihEAW!5E NOTED. b) 5741 TR1A'fiES AE15i DE !hSiALLED WITH THE i0P DEING UP. 7)ALL ROOF FW54HANGERS10OESW50N HTu26uFiE5S01HERwI5Era71EC, rel FLOOR , KW N-ANSER5 TO DE SU.1P50N THM72 LKE% OTHERWISE NOTED. D) DEAMIREADERA.INIEL (TGR) TO OE FUR cAED DY MLDER SHOP DRAWING APPROVAL TNS LAYOUI IS TIE SOLE SOAE FOP. FAD1Yd11011 OF iRlffiES AID v0EA5 Nl !rEV I ARGOTt I I OR OVER 1LIIASLAY01,1I5 RfVIEWAID AOPROVALOfTIS LAYMUL91 DE RfLEIVEO DEFORE ANY TMLS R'A1 DE "' .1 VEITFY AU (QDIIM TO WO AGAINST UI NSE$ THAI 111k C110.1 W EKErA CHAMS 10 TOO t4 -t" Ftlrrl Wu ®Builders . FirstSource Orlando RHONE: 407.651.2100 FAX. 407-e31-7111 Plant City RHONE: 915.759.5951 FAX: 9115.732.1532 Taylor Morrison Homes II: Daphene III B AIADF11% 11161ft Lot 3oc . In 1: to►. 2-16-16 Rick yj�Cm.1 �� �� � w�'a 1� 0� 11�� O�l� C�.1� U �1 e� �.!•1'��.0� ���'� ��.0���� � �a:0��1 v�_1� D V f11��1: i s -•; I i R ►, ►(� CD 0 1 a A �— � / A ►j n©- I CO (11 ; CO W "I 7 ; 7 CO 00 CO 28-04-00 II" OJ��DING SANFppD p1-PAR.�,. #16-2686 + •i OCT - 4 20'.rj ; BY. GEARING HEIGHT SCHEDULE rz//z/M 9.-q. 20'-3/4' 0 0 Hanger List H1 HTU26 H2 THA422 NOTES: t) REFER TO He 91(RECO WEFDATI" FOR HAIAD+6 INSTALLA*.ION AND 1 E..MIPOIZAAY D9AC11:5 ) REFER TO ENGINEERED DRAWIN(h FOA FERMrN'_4T DI:ACIM REOAREC. t) ALL TRU55E5 (61XLUDIR6 TRU55E5 Pak VALLEY FRAMM)-Ahi 9E U#4? E1ELY DECKED Or REFER T, 9 DtTAiI V1C9 FDI; ALTEINAIE DRAPING REAAREMENTS 3) ALL VALLEYS ARE T. DE (OWEATIO N I LY FRAM IY WIDER 4.) ALL TRUSSES AAF DE'.16NED rOR MAXIMII.I SPACING. I►AE55 OTHERWISE NOTED. 5) ALL WALLS SHOWN ON rLACF.EtiI PLAN ARE CONSIDERED TO DE LOAD DEARRNa LNE75 OihEAW!5E NOTED. b) 5741 TR1A'fiES AE15i DE !hSiALLED WITH THE i0P DEING UP. 7)ALL ROOF FW54HANGERS10OESW50N HTu26uFiE5S01HERwI5Era71EC, rel FLOOR , KW N-ANSER5 TO DE SU.1P50N THM72 LKE% OTHERWISE NOTED. D) DEAMIREADERA.INIEL (TGR) TO OE FUR cAED DY MLDER SHOP DRAWING APPROVAL TNS LAYOUI IS TIE SOLE SOAE FOP. FAD1Yd11011 OF iRlffiES AID v0EA5 Nl !rEV I ARGOTt I I OR OVER 1LIIASLAY01,1I5 RfVIEWAID AOPROVALOfTIS LAYMUL91 DE RfLEIVEO DEFORE ANY TMLS R'A1 DE "' .1 VEITFY AU (QDIIM TO WO AGAINST UI NSE$ THAI 111k C110.1 W EKErA CHAMS 10 TOO t4 -t" Ftlrrl Wu ®Builders . FirstSource Orlando RHONE: 407.651.2100 FAX. 407-e31-7111 Plant City RHONE: 915.759.5951 FAX: 9115.732.1532 Taylor Morrison Homes II: Daphene III B AIADF11% 11161ft Lot 3oc . In 1: to►. 2-16-16 Rick