HomeMy WebLinkAbout116 Bristol Forest TrlCEY `TE13 CITY OF SANFORD BUILDING & FIRE PREVENTION F D FEB 16 20% PERMIT APPLICATION gy: Application No: Gj Documented Construction Value: $ b Address: 114 /3z/S7-7)C- ge-tar m 1 w/G<o k 3Z77/ Historic District: Yes No Y -rcel ID: M Do- 0/30 Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move x Description of Work: 7 601A_)o6cuS ,9k30 / ,0Od-c- Ian Review Contact Person: L./ti/a Title: R:2i1-7 Phone: Sz1 Zyy/S- C'Zil3 Fax: L107- L/90-T3d0 Email: ri-71rf (3 1N4 D®yc J• God Property Owner Information Name 35//61 Street:- City, State Zip: Phone: C/D -7 `// S a & 6 Resident of property? : Contractor Information Name Phone: - 9tl_'79z tIV&—*- z(ye-3 Street: 110-7d 9 3 o a9 v Fax: Vb -7 — LIv%2 —e3y City, State Zip: A /LI oc) p 333/Z State License No.: c 6-C 06 te? C) Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code /a j Revised: June 30, 2015 Permit Application ' A NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, i- r accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction valu . credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work My*` be done in compliance with all applicable laws regulating construction and zoning. r, Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent Date Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[-] Roof Construction Type: Occupancy Use: Flood Zone: _ Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: June 30, 2015 Permit Application MA Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. ti OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EWPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to -the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. J Signature of Owner/Agent " Date C"A- nP=q ye- Print Owner/Agent's Name Signa of No F1 Date CAFIOW ` N $EE829279 2p16 E)(P19ESePecUnderv+rllers V'yr gonded'(tiN Owner/Agent is P e or Produced ID T of ID APPROVALS: ZONING: 9-156- lei" ILITIES: COMMENTS: ENGINEERING: 1-h S;6c%C FIRE: igna Date WAYNE T. BURNETT Print Contractor/AmftName of Florida Date CAMO MMONEZyrvax., N 1f EE 829279 r, AiY C,OMMISS104ef 23, 2pt6 EXPIRES: Dece pubNcUnderwntersndedThNNotaY Contracto y own to Me or Produced Type of ID WASTE WATER BUILDING: 2-go A.. Shall be inscribed with the date of application and the code in effect as of that date (Code 2010 FBC) 731.135(5)(6) Florida Statutes. REV 07.14 REQUIRED INSPIEcCTION SEQUENCE BP# &I I-Addeecc! /!G 1-f .-I IBMI ,IlDINGIPE'9tly IT 111minIMax16trncrtupetinymUl)eeptninih n if Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing —Roof RoofDry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen,Enclosure Mobile Home Building Final Pre -'Demo Final Demo Final Single Family Residence Final Building (Other) REVISED: June 2014 Min Max Inspection IlDeselrn t-lon Electric Underground Footer / Slab Steel Bond Electric Rough T.U:G. Pre -Power Final - Electric Final Min Max ffns, ecbuon Deseni2tion = Plumbing Underground Plumbing Sewer Plumbin Tub Set Plumbing Final - CH:?!` ICA`I -PIMD? , T Min Max Ins, ection Il u®n Mechanical,Rough Mechanical Final 7-7 1M 1[IIIl Max Impection BeS2 1llo m Gas Underground Gas Rough Gas Final I Ililll iilll Ilili lllli illil lilil fill IlIITHISINSTRUMENTPREPAREDBY: Name: BARBARA ESPARZA Address: FLORIDA HOME IMPROVEMENT Ao . MARYANNE MORSE? SEMINOLE COUNTY 4070 SW 30 AVE_ HOLLYWOOD. FL. 3 312 CLERK OF CIRCUIT COURT & COMPTROLLER State of Florida County of Seminole BK 8633 F's 1911 (1 F'ys ) CLERK' S 2016016688 RECORDED 02/16/2016 12:22::;4- P11 RECORDING FEES $10.00 RECORDED BY hdevore Permit Number: _- - _ Parcel ID Number. 22-19-30-502-0000-0130 The undersigned hereby gives notice that improvement wig be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LOT 13 PRESERVE AT LAKE MONROE PB 62 PGS 12 -15 116 BRISTOL FOREST TRL SANFORD, FL 32771 GENERAL DESCRIPTION OF IMPROVEMENT: WINDOWS AND DOORS OWNER INFORMATION: LcRTIFIEDCOV CUITCOURT LERK Name: $ROEKER CRAIG N 8r CHRISTINE OF THEOvk LLER Address: 116 BRISTOL FOREST TRL SANFORD, FL 32771 u1OLE000 Fee Simple Title Holder (if other than owner) Name: n/a Arlrlracc• n/a 9Y t CONTRACTOR: Name: FLORIDA HOME IMPROVEMENT ASSOC. Address: 4070 SW 30 AVE. HOLLYWOOD, FL. 33312 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: n/a Address: n/a In addition to himself, Owner Designates n/a of To receive a copy of the Lienor's Notice as Provided In Section 713.13(1xb), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date is specified) WARNING TO QW7VER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. r CV1 f i S Owner' s Signature I Owner's Prim ed Name Florida Siahrte 713.13(1 xg): ' The owner must sign the notice of commencement and no one else may be pemtitted to sign In his or her stead.' State of _ County of 5-r-' • The foregoing Instrument was acknowledged before me this day of by Ch K i c2h LA b r QPk Who Is personally known to Name of person making statement OR who has produced identification type of identification produced: CAROM MAFMNQ MY SSION t P RES ipecembe 23, 2016 Bonded Thor I, taq PU Nc Iindelwaem 2016 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwoo , Sanford, Seminole County, Winter Springs Date: I hereby name and appoint: LUIS COLLAZO an agent of: FLORIDA HOME IMPROVEMENT ASSOC. Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: 116 BRISTOL FOREST TRL. SANFORD, FL 32771 Street Address) Expiration Date for This Limited Power of Attorney: License Holder Name: WAYNE T. BURNETT State License Number: Signature of License H STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this day of, 200*, by WAYNE T. BURNETT who is personally known to me or who has produced as identification and who did (did not) tak e 4th' Signa u re n Notary Seal 7 I Print or type name Notary Public - State of 411 Commission No. Lci Z My Commission Expires:' NFL 9 Rev. 08.12) LUM a enft 074MOM Fmdda Hama lmpovarnard taoodares Brovord TSL O54-7D2.4415 Ltoeataa Ne cull oFRpO QB ittB Mianr OWN Tbi: 305446 4400 tHeet Li TM• list 241 WW AM SW 30° An., FL 33312Y le Tr 15JedotorhAkTel; 004.70f•4415moor N 'a Fcc G647a70 wubefte: yMlf}M1H[OgUCTa.GOMAOMjp(}I fieplaoemant Windows Cotnrllot Sraaltnf M61F (APROOItC IIIAM Name: l.Itn`t Amkg ti--Phony::LOI-4ls'2"V Bus.Phone: Address ryMy slope zip Thls amtract is made and entered into this ZR day of 20[ ! L_ by and beg m Oorlda It .-Itapravemant Aa.O tas, ft., e Florida corporation ('Contractor or'FHA'}. and ownt*) earned above of the rildence located at the address listed above ('Owner'). The Contractor Wm to pe4orm the work described below: tj Reams, Olds a unita to be replaced. {WM Removed hems are MwIV to be damaged.) Dbecdom arsr'4-raad IMr the km*' 2) Prepare openjW as noctisary to rem We Mplaoenift eatb. On WMft 0" imm Actm and road vrdak ova MdarteMlad. ttr QuasNsfs 3) WXDON'S: RA Energy S1omr Safer _ %nor n VW bneufabd and dusk a * w h d ISU0011111t>ytaa• beat l Aluminum IMAN116d,_ Akanknxn NoMMAIted On Ocubiwounch Cam the two 4) Aaors: FfiAEner®t8loltnb rir_ AkaNrnastllnp/>awi _ NaevMNa [rwJ9*d aetivedoorMMeatlRad Impact { ) Honlmpcce: { } Cblb, -VA Fteo Tan: luoraa: Grty: . Mill Fk shd Double Him st. ro QtV— aw car Aerrva FA 11F E91mX QLYH RHEM ntfr— a gnu am AA AF FA FAAF AAF FAA my;,,,_, "L Qtv— W Qty Qtr ttll( I WI I Qty W ) W ) Q%V t GhM %g Ot•Vp. tea. ttnit.ada,tQ, r+ rCi : s-6*6 f*iPi(!C } " ' alrAtuLttt - 1Narrw*r. Minus meswarmitysrrduponmrl 5) WorkNQitoberepiaced: 7NlilALHERH 6) HapplicaloK renic-AM shutter penal% and/or sacurky bars, rNITIO to REa 7) Special6sstrued--. C7eamp)abdeblhandpmulderta wwpertnfi4arWirm ice. Nsppllcab)q kyttta eventlhatCiantractOr k unablefar Whatever rgsonto abtaAt proPu parm)ts ghee to a0mmntcemerrtatarryvvoriS, Contractor Ad rafend any pftylow payment and this psasactfos e)adl be automatically No finish watApthertfnnnafmalkisW_latfontstobodome onleanope balowj .. A _ . . -" _ . n Cantractmrshallcommencetbewarkwkhlniii dayfattorammMonafdneCartratt(the` eommentementDIM-)andSWendeavorto eompleteagWerkheravoclarwithksdaysaitartheiom+ntrKemtntDoe. CD( MIctMe $ rt7 theTOTALPRICEfor altAborand MalerWxf % Wch ganyappRcabitdiveount)Is S 9an3: m swT-L-Oppacableio $ luvmAaymant $ - •44 yftamraetprice $ I 8alarYst Payable $ . Canaractor will provide to Owner a FM WOM and Release of teen and tsrMractor's Heal AMdr& to owner, rtlaRy slmliar ter thetorms ltrckufedfncararler 5tahresf2op51. on (yES Na JgswserekcrsibapplyjorJ hanthryoftbeabovestah+ elumpsamo»+ounLffyatrdnirdsse inandrrpapreementrretlrttewoee+n.Irfasertisb,aa baraa. adae.+ura.rw: a). oo eotAPttishwe iaproreamttatrenet!{ecWdlatwnand+ s loraoental lnbhhNr b).VouovaerndeNmemryNtlrceateattetlfrrbaeyoaelpr treghasFrateayaarkplApru. c).TM fl,netW doaeearre aaatl+ed to they Ibararwaa.unuxmsuaatwercentdna raarraaae ordfwadaetsaale r lien an yadrravewestytiratwdd fee ihraWdd ar Myoa do aotaer. A sent you ruMtdatend s/wwr4lasKaFtdeoonsactand Mrardat doaeaena trebro voU*M Macellinamn; This contract contains the entire contract of the garde. R otay )rot be changed onVy but only by a Agned change order or other written anxndment. The waiver by any Putt' of a breach of any prmrislm of this contract shell rat operate or be cwMratd as a waiver of my subsequent broth by arty party. IN WITNESS WHOMCF, the Parties hereto have executed thh contract, under seal, as of the day and year first abaft written. Youths fsuyw my carom lids han"coon rat any um pow to ltrfdrdpht on the t M bunkum day ahoy OW d" 03 this ftrAUUaa4 Gee the srttaehsd stance, of aanaallatfon fomt for an mgdenaf o of Oft filim Owner. ., Contractor. FHA BY: n a of j ( Name & Tltlel Sl$nMure of Own.) Date HomeO nersAssociardw Noma. ptonem 4n'- 133-13SI J YES (/) NO ( ) BundinsName: t +lu 14d . SCPA Parcel View: 22-19-30-502-0000-0130 http://www.scpafl.org/ParcelDetailInfo.aspx?PID=22193050200000130 David Johnson CFiA Property Record Card PROPERTY Parcel: 22-19-30-502-0000-0130 A,PPRMSER Owner: BROEKER CRAIG N & CHRISTINE M SWW40LE COUNTY, FLORIDA Property Address: 116 BRISTOL FOREST TRL SANFORD, FL 32771 r Parcel: 22-19-30-502-0000-0130 Property Address: 116 BRISTOL FOREST TRL Owner: BROEKER CRAIG N & CHRISTINE M Mailing: 116 BRISTOL FOREST TRL SANFORD, FL 32771 Subdivision Name: PRESERVE AT LAKE MONROE Tax District: 53-SANFORD-WATERFRONT REDVDST Exemptions: 00-HOMESTEAD (2015) DOR Use Code: 01-SINGLE FAMILY 7w _ r VBtV O• eRiSrO RFST C` Value Summary 2016 Working Values 2015 Certified Values Valuation Method Cost/Market Cost/Market Number of Buildings Depreciated Bidg Value 1 1 141,958 136,816 Depreciated EXFT Value 2,301 — 2,401 — Land Value (Market) 34,000 30,400 Land Value Ag Just/Market Value 178,259 169,617 Portabty Adj Save Our Homes Adj 7,455 0 Amendment 1 Adj Assessed Value 170,804 169,617 Tax Amount vkhout SOH: $2,630.59 2015 Tax B7 Amount $2,630.59 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments 1 of 2/1/2016 10:41 AM I RECORD COPY z ..D. City of Sanford k Building and Fire Preventi FEB 16 2016 Product Ap roval Specification F WED MRCODE COMPUkNCE l D NG PLANS EXAMINER s 5 2 2 SANFORD Permit # DATE Project Location Address, 5 -o As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding C:;> t 3 . Sectional Roll U Automatic Other 2. Windows Single Hun C_L—) Horizontal Slider Casement Double Hung Fixed Awning Pass Through Projected Mullions Cat) S LO, Wind Breaker Dual Action Other June 2014 LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Mn Category/ Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category/Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name "c_p bJI(( if - Please Print) June 2014 E A-Dl AGRA M SHEET F'Ior6aH o A sooism 'os vmstforea MEASURE DATE CUSTOMS NAME LEAD NUMBER TYpE OF PflOPERTY 2/8/2016 niHal ht MEASURETECH SH Broeker 311790 Sin le Fami 351/2 x 0 SH Fx 36 3/4 FL4o91. 1 SGD 711/ 2 x 791/2 60) FL11103.1 P6 Q--c lAr-4- L' th ev MULLION 1 x 3 NOA# FL9520. 1 (+/-80) SH 351/ 2 x 611/2 So) FL4091.1 SH 351/ 2 x 611/2 So) FL4091.1 Florida Building Code Online Pagel of 3 ap pggd BMSHeme ! login ! user Reghtation I Hot Topic I Subrnitsurcharge I Busines, Professi l '" 1f o duct Approve[ USER: Public Uses Regulation VI" sets & NCI Pubikatior. ! Fac SW ! sas Sta Haa 1 cons I sa3reh ! Product Aoorwal Menu > Product or Aoollcatron Seartlr > Anolkation List > Application Detail Fl-# FL4091-117 Application Type Revision Code Version 2014 Application Status Approved Comments Archived p Product Manufacturer Custom Window Systems Inc. Address/Phone/Emall 1900 SW 44th Avenue Ocala, FL 34474 352) 368-6922 ekoss@cws.cc Authorized Signature Koss Erin ekoss@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Emall 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 6Z Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE FZ Validation Checklist - Hardcopy Received FL4091 R7 COI EvaiReo CWS-iSaF tsH_stt00 NI) odf Standard AAMA/WDMA/CSA/101/I.S.2/A440-05 AAMA/ W DMA/CSA/ 101/I, S.2/A440-08 ASTM E1300-04 PA TAS 202 Year 2005 2008 2004 1994 http://www.floridabuilding.org/pr/pr_app dtl.aspx7param--wGEVXQwtDquz931%2b4g5fa... 6/24/2015 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/09/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Sununary of Products EFL # Model, Number or Name Description 4091.1 SH-8100 8100 Vinyl Flange/Fin Frame Single Hung Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: YesDesignPressure: +50/-5D Evaluation Reports Other: SH-8100, Max. size 53,125" x 76. Glass complies FL4091 R7 AE FvalR o CWS-f SaF rSH_Q nn w :a with ASTM E1300-04. Created by Independent Third Party: Yes 4091.2 SH-8100 SH-8100 Vinyl Single Hung, Non -Impact. Limits of Use Installation Instructions Approved for use in HVHZ.- Yes E? 4091 R7 It CWS-48 B (SH-8100 52x71 NI).PdfApprovedforuseoutsideHVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: YesDesignPressure: N/A Evaluation Reports Other: SH-8100 Vinyl Single Hung, OX, Max. size 52" x EL4091 87 AE EvalReo CWS-485B (SH-8100, 5 x71 71', see Installation dwgs. for DP. Glass compiles with ASTM NI),pQf E1300-04. FL4091 R7 AE Quanex(Mikron) NOA 12-1017 02 odf Created by Independent Third Party: Yes 4091.3 iW-8110 Continuous Head & SIII SH-8100 Vinyl Single Hung, Continuous Head & Sill, Non - Impact. Limits of Use Instaltation Instructions Approved for use In HVHZ: No FL4091 R7 II CW -4426 tSH_81 nn 74x63 ContHdSl. Approved for use outside HVHZ: Yes r cl f Impact Reslstenta No Verified By: Lucas A. Turner 58201 Design Pressure: N/A Created by Independent Third Party: YesOther: SH-8100 Cont. Hd. & Sill, Max. size 72 7/8" x 61 Evaluation Reports 3/4", DP +67.5/-70 psf. Glass complies with ASTM E1300- FL4091 R7 AE EvalReo CWS-442B ( H-81nn 74x63 04. ContHdSl, NI).odf Created by Independent Third Party: Yes 4091.4 SH-B100 Continuous Head & Sill SH-8100 Vinyl Single Hung, Cont. Head & Sill, Non -Impact. Limits of Use Installation Instructions Approved for use in HVHZ: No FL4091 R7 II CWS 4928 (SH-8100 74x72. ContHdSl- Approved for use outside HVHZ: Yes Ni),pd Impact Resistant: No Verified By: Lucas A. Turner 58201 Design Pressure: N/A Created by Independent Third Party: YesOther: SH-8100 Cont. Hd. & Sill, Max. size 74 1/8' x 72", Evaluation Reports see chart on installation dwgs, for OP. Glass complies with FL4091 R7 AE EvalReo CWS-4gJR rSH_R1nn aY» ASTM E1300-04. ContHdSl. NI).odf Created by Independent Third Party: Yes 4091.5 SH-8100 Oriel 8100 Vinyl Single Hung Oriel w/ HD Meet. Rall Limits of Use Installation Instructions Approved for use In HVHZ: No FL4091 R7 II CWS-293 ( H-8100 52x96. nn).p dfApprovedforuseoutsideHVHZ: Yes Verified By: Lucas A. Tumer 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: SH-8100, Max. size 52" x 96", Oriel. Glass complies FL4091 R7 AE Fv52x96, with ASTM E1300-04. Ni),odf Created by Independent Third Party: Yes NeKt http:// www.floridabuilding.org/pr/pr_Opp_d#1.aspx?param=wGEVKQwtDquz931%2b4g5fa... 6/24/2015 Florida Building Code Online Page 3 of 3 The State of Florida is an AJEEO employer. Copyright 007-2013 State of .i:_ :: privacy Statom,.nt :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mall address released in response to a public -records request. do not sendelectronicmailmthisentity. Instead, contact the office by phone or by traditional mail. If you have any questlon% please contact 850.487.1395. -Pursuant toSection455.275(1), Florida Statuses, of alve October 1, 2012, licensees licensed under Chapter455, F.S. must provide the Deparbnent with an emall address Utheyhaveone. The emans provided may be used for official communication with the licensee. However emall addresses are public record. Ifyou do not wish to supplyapersonaladdress, please provide the Department with an email address which can be made available to the pubic. 7o determine it you are a licensee under Chapter455, F.S., please dick hiss., Product Approval Accepts: go ® E.R. creditSArFE http:// www.floridabuilding.org/pr/Pr app_dtl.aspx?Param--vGEVXQwtDquz931%2b4g5fa... 6/24/2015 URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 154E April 3, 2015 Product Description: Series 8100 PVC Single Hung Window, Non Impact, 53 1/8" x 76" unit size, 54 3/8" x 77 1/4" flange size Manufacturer: Custom Window Systems, Inc. 1900 SW 40 Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 5`h Edition (2014) Florida Building Code outside the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-154E, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3809-1 and -lA, from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E. a. Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-154E, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-154E. Limitations of Use: This product: May be used in the configurations and sizes and with daylight openings as indicated in CWS-154E Achieves design pressures as indicated in comparative analysis table in CWS-154E Is non -impact and requires the use of shutters in windborne debris regions May not be used in the High Velocity Hurricane Zone Requires glass as shown in CWS-154E Requires Quanex (Mikron) white rigid PVC extrusions as shown in CWS-154E Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. t*tt Ytt tiit I2REW i zftE.TJe No 58201 t n: :a: STATE OF: :'u 4/3/2015 P, ;,*` t Lucas A. Turner, P.E. NA ll FL PE #58201 0 I IF Lucas A. Turner, P.E. 2015-04-03 10:00-04:00 UNIT SINGLE HUNG - NON -IMPACT SHOWN w/DIFFERENT OPTIONS) . 54 3/0- MAXOVERALL FLANGE WIDTH 53,A,' MAX. UNIT WIDTH 48 15116' GLASS DLO A I 335116" 691/ O 2' I GLASS MAX B DLO OVERALL B FLANGEHEIGHT fie }/4• B MAX 16' UNIT TC33wwHEIGHT X I 6 GLASS MAX IT A I DLO I CAM 8 AB Sry J I EQUAL SPLIT 54 3Ar — MAXOVERALL RANGE WIDTH 531/5' MAX UNIT WIDTH 4815/16' GLASS DLO C X I+-- 46SM(r --I GLASS DLD 60/40 SPLIT ORIEL TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS ....1 DP CHARTS & GLAZING DETAIL._._.2 SECTION VIEWS & ALT. FRAME .„..... 3 EXTRUSIONS & B.O.M............ _........... 4 ANCHOR SCHEDULE & NOTES ._....... INSTALLATION DETAILS.....................B 54 3/8' MAX OVERALL FLANGE WIDTH 531Ar MAX uNrTWrDTH 48 15/16' — GLASS DLO C X Imo- 46 5/16' --1 GLASS DLO 5 HI SASH ORIEL GENERAL _NOTES; 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION. 2. GLAZING OPTIONS: (SEE SHEET 2) 3. CONFIGURATIONS:'O/X'. 4. DESIGN PRESSURE RATING (SEE SHEET 2): NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-130D-04. POSRTVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300.04. 5. ANCHORAGE: THE 3315%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR DETAILS. W INDLOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND JAMB. 8. SERIES / MODEL DESIGNATION SH-81 OD. 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X - OPERABLE SASH, O - FIXED SASH 10. SECTION CALLOUTS FROM EQUAL SPLIT ELEVATION APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. 11. EXTERNAL WEEP SLOT .1/2' x2-1 /2' LOCATED 4' FROM BOTH ENDS. LucasTurner 2015-04-03 09:55-04:00 CO QUAL 5 HI OR E 53-1/8" x 76" x 68-1/4" DESIGN PRESSURE RATING IMPACT RATING SEE COMPARATIVE ANALYSIS CHART, SHEET 2 NONE NONE 60/40 ORIEL 53-1/8" x 62-1/16" NONE 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WW W .CWS.cC 8100 PVC SINGLE HUNG NON -IMPACT No 58201 w STATE OF X. 4/3/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1674 GENERAL NOTES AND ELEVATIONS DA BAT 04/29/08 CWS-154 E SHEET 1:33.33 1 OF 6 Unit Sash UeSIgn Pressures (P5F) with Glass Types A, B, C, or D UnitMdths In. Helghts(in.) Heights(In.) 23 1/2 1 27 1/2 29 112 31 2 1 35 1/2 39 2 41 2 43 1/2 47 1/2 51 2 53 1/8351/2 17 50/-75 1 +50/-75 50/-75 50/-75 5D -75 50/-75 50/-75 50 -75 50/-75 50/-75 50/-75391/2 19 50/-75 1 +50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75411/2 20 50/-75 1 +50/-75 50/-75 50 -75 50 -75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-73.14322150 -75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50 -75 50 -73.4 50/-70.6471/2 23 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50 -75 50/-68,9 50 -66.2511/2 25 50/-75 50/-75 50/-75 50/-75 50/-75 50 -75 50/-75 50 -75 50/ -72.7 50 -65.2 50/-62.65322650/-75 50/-75 50/-75 50/-75 SD/-75 50 -75 50/-75 50/-75 50 -71 50/-63.6 50 -61551/2 27 SO/-75 50/-75 50/-75 50/-75 50/-75 50/-75 SD -75 50/-75 50 -69.5 50/-62.1 50 -59.5591/2 29 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-75 50/-66.8 50 -59.5 50/-57631/2 31 50/-75 50 -72.9 50/-72 50 -71.6 50 -7L6 50 -7L6 50/-716 1 +50 -7L6 50 -64.6 50/-57.3 1 50 -54.86523250 -73.2 50/-69.1 50 -68 50 -67.4 1 50/-67.3 50 -67.3 50/-67.3 50/-67.3 50 -63.6 50 -56.4 50 -53.9671/2 33 50/ -69.8 50/ -65.6 50 -64.4 50 / -63.7 50 -63.4 50 / -63.4 50/ -63.4 50 -63.4 50 -62.7 5o/ -55,5 50/-53711/2 35 50/ -64 50 -59.7 SO/ -58.3 50 -57.3 50/ -56.5 50 -56.5 50 -56.5 50/ -%S 50/-56.5 50 -53.9 50/-51.5744365/8 50/-59.9 50/-55.6 50/-54.1 50/-53 50/-518 50 -5L7 50/-51.7 50/-5L7 50 -51.7 SD/-51.776371/4 1 SD -58.5 1 50 -54.1 50/-52.6 50/-SL5 50/-50.2 SO/-50 50 -SO 50/-50 50/-SO 50/-50 50/-50 7/8' OVERALL 1/8' ANNEALED W AIR SPACE 11B" ANNEALED SIKAPLEX 552 OR PURFECT GLAZE -W 1/2- GLASS SITE TYPE A GLASS TYPE B NOTE: IF SIZE INTENDED IS NOT SHOWN, USE NEXT LARGER SIZE 7Ai OVERALL 3116' ANNEALED 117 AIRSPACE 2116' ANNEALED S0(AFLE( 662 OR PURFECT GLAZE "W 1/2' GLASS SITE TYPE 71W OVERALL 1/e' TEMPERED 5V AIR SPACE 1B"TEMPERED B FLCT5- W 1/2- GLASS SITE GLASS TYPE D i/S" OVERALL 1/16" TEMPERED Ire AIRSPACE 1/16' TEMPERED SIKAFLEX s52 OR PURFECT GLAZE "H' 1/2" GLASS SITE 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.OWS.CC 8100 PVC SINGLE HUNG NON -IMPACT N R ( LL No 58201 STATE OF 4Z3l201 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-38D-1574 guff-DE-s-dolow- COMPARATIVE ANALYSIS AND GLAZING DETAILS BAT 04/29/08 mm r. CWS-154 E SHEET 1:1 20F6 INTERIORwmwwmnmmaomm 1900 SW 44TH AVE. OCALA, FLORIDA$074 t 1 WWW.CWS.CC 8100 PVC SINGLE HUNG NON -IMPACT 1 gm mLa1OO O ww} Q Q m 3 I 1 1 4 SECTION B-B ZQ oLLF U yy CDZNOTE: LEFT SIDE SHOWS FIXED SECTION VIEW, RIGHT SIDE SHOWS SASH SECTION VIEW. 0 1 N C Z W a wQ 4 g FoFOC 6 INTERIOR w e U m a 9 e e MEW g •P'GA 3i No 58201 g 6TATE OF- 40S4/3/2015yoLUCASA. TURNER, P.E. FL PE # 68201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION C-C SHEET DESCFWr)ON; ALTERNATE FIN FRAME SECTION A -A SECTION VIEWS NUFWWBT'.— BAT 04/28/08 CWS 154 E NOTE: ITEMS NOT SHOWN FOR CLARITY: 20, 23, 26-26, 31, 38, 37, 44, 51-62, 55-56, 64, 67-68 12 SHEET 3OF6 3 x5wx PVC FRAME FIN H-8026 Sr18" 1 PVC SCREEN SUPPORT S-6014 1 15r18' FE 1116' PVC SASH BTM. RAIL H-6028 1 3/18' I E 1 T- PVC SASH SIDE RAIL H-M4 1 1/8• Ire 1/18' PVC SCREEN CATCH S•BD13 3ns'I 1• 9 i REINF- SASHMTG.RAIL REINF-SSR/SSR H-1497 S-1498 1/z• 3/18' 1 SCREW SUPPORT P-3113 Shea 3 d 3 Duraseal A 3) Dumasel criz- Allmetal Almon Bit. Allmetal A arler Key Asmetal Plastic x 16 Flbetgiaas ottenm I s 55 Dia., Btk.Dapa Vinyl Summit Alum S FI. Screen SS 1n., PVC MR VI PVC T. Pl6atica Nylon ron I Vinyl LINE ITEMS NOT USED: 6-7,11, 21-23. 29. 31, 41-43, 47, 49-50, 57-61 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. j+-23J16' I e 1/16' PVC SASH MTG. RAIL H-6027 t 12• 5 2 1/8' 1/r FIXED MM. RAIL H-1836 1 L 1l18• PVC SASH STOP S-6029 1/4' r t 7- 1 1 t PVC GLAZING BEAD S•6064 9116, 1 6/16' 1118' PVC FIXED RAIL COVER S-6063 FRAME CORNER CONSTRUCTION CORNER W ELD ALL SIDES) IS FD(ED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME it 190D SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC VIWPVC SINGLE HUNG NON -IMPACT S.p7 0 ,6 STATE OF ON 4/=015 LUCAS A. TURNER, P,E. FL PE A 58201 1239 JABARA AVE. NORTH PORT, FL34288 PH. 941-3804574 BOM AND EXTRUSIONS BAT 1 04/29/08 CWS-154 E SHEET 1:8 40F6 4: MAX. O.C. 6• MAX (TYP.) 6• MAX (M.) MAX. O.C. N ° TYP-) 1 4• (TYP) J I 4- (TYp) III X n 2 INSTALLATION ANCHORS TYP. 4• MAX (TYP) 4• MAX C".) 8• MAX O.C. Typ.) THRU FRAME ANCHOR AT FD(ED MEETING RAII TYP.) TE 2 INSTALLATION ANCHORS TYP. NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REO AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4'. USE SHIMS WHERE SPACE GREATER THAN 1/16' IS PRESENT. LOAD BEARING SHIMS SHALL BECONSTRUCTEDOFHIQHDENSITYPLASTICORBETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFED IN THESE DRAWINGS. SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT W TTH PRESSURE TREATED WOOD MUSTBEPROTECTEDTOPREVENTREACTION. S. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUMSPECIFIEDINTABLE1, SHEET 6. S. ANCHOR EMBEDMENTTO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHAD- BE BEYOND WOOD BUCKS. IF USED, INTO SUBSTRATE - iX BUCKS AREOPTIONAL 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3' FOR MASONRY, 1• FOR WOOD AND METAL B. WOOD OR MASONRY OPENINGS, BUCKS AND BLOCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET. SHEET6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 1O0(FIN WIN)OWS), FMA/AAMA 2GG(FLAN(3E W INDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMAAYDMA 3G0(EXTERIOR DOORS) 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG NON -IMPACT 3F tie 58201 'p oz STATE OF Fkl L Fti OR1Dv• r gyp''•....,..• Q 4t 4/3/2015 LUCAS A. TURNER, P.E. FL PE # 562G7 1239 JABARA AVE. NORTH PORT, FL34288 PH.941-380-1574 ANCHOR SCHEDULE At NOTES BAT 04/29/08 w. ., GWS-154 E zxm1.25 SHEET 6OF6 TYPICAL HEAD ANCHORAGE MIN. EDGE DIST. SEE TABLE I SUBSTRATE BY OTHERS SEE TABLE 1 MN.EMBEDME PERIMETER SEALANT SEE TABLE I BYINSTALLER INSIDE AND OUT SEALANT BEHIND FLANGE BY INSTALLER 1/4• MAX SHOA INSTALLATION SEE TABLE I i 14' MAX SHIM SEALANT BEHIND FLANGE BY INSTALLER PERIMETER SEALANT BY INSTALLER MIN, EMBEDMEN INSIDE AND OUT SEE TABLE I SUBSTRATE BYOTHERS SEE TABLE 1 MIN, EDGE DIST. 6EE TABLE 1 MIN. EMBEDMENT SEE TABLE I SUBSTRATE BY OTHERS 1/ 4' MAX SHIM SEE TABLE 1 MIN. EDGE DIST. SUBSTRFATE SEE TABLE 1 SY OTHERS 1900 SW 44TH AVE. 1/ 4" MAX SHIM SEE TABLE 1 OCALA. FLORIDA 34474 W WW.CWS.CC MIN. EDGE DIST. SEE TABLE 1 INSTALLATION ANCHOR 8100 PVC SEE TABLE I / SINGLE HUNG MR EMBEDMENT SEE TABLE 1 NON -IMPACT PERIMETER SEALANT BY INSTALLER INSIDE AND OUT SEALANT BEHNb FLANGE BY INSTALLER HGRIZONTALIS: ECZTIO N TABLE 1: APPROVED INSTALLATION FASTENERS n8mL= sum ANCH15111 ME CONCRETE ( 2.0 KSI MN.) 3/16• RW TAPOON 1• NGEFLAE1' 2- FLANGE CONCRETE (2-85 KSI MOM.) VlW ELCO ULTRACQN 1' 1 FLANGE GROUT FILED CMU (ASTM C-90) Yl ELCO ULTRACON Ille 2-W FLANGE 2XMN. SOUTHERN PINE (G.0.69 18" ffW A OR ELCO UL'IRACON 1-w 7/8' FLANGE 2XMIN. SOUTHERN PINE (G.0.55) 10 WOOD SCREW 1 3/8' 7/8' FLANGE 16 GAUGE (0.080") MN. STEEL STUD 33 KSI YIELD MIN) 10. 16 HIL.TI KWI -FLEXOR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.080' 7/1T FLANGE 1l8" ALUM, (8D63-TS MN.) OR 1/ 8" STEEL (33 KSI MIN.) 410 GRADE 5 SELF-TAPPND / DRLLNG SCREW FULLTHREAD THRU 0.125' 7/18' FN 2XMIN. SOUTHERN PINE (G.0.W 010 WOOD SCREW 1-1/2, 1/2 SEE TABLE 1 SEALANT BEHIND FIN BY INSTALLER HORIZONTALSECTKN4 B TYPICAL FIN ANCHORAGE HEAD AND SILL SIMILAR FOR FIN INSTALLATION t 1 Z F LL O 52 tad p v : No 58401 : A v: 9\ STATH OF •W' DA 4'OC 0" zz 4/ 3/2015 LUCAS A. TURNER, P.E. FL PE # 58201 PERIMETER SEALANT INSTALLER 1239.1ABARA AVE. IN INSIDEAND OUT NORTH PORT, FL 34288 HORIZONTAL SECTION PH. 941 380.1574 e BOX FRAME INSTALLATION SHEET SItdILA9 FOR SILL AND JAMB8 FOR BOX INSTALLATION INSTALLATION DETAILS FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED: MIN. 1/4- FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED BAT e r 04/ 291013 INSIDE AND OUT, FULL PERIMETER, BY INSTALLER PRODUCTANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS CWS 154 E SHOWN FOR FLANGE WINDOWS. SHEET 12 6OF6 Florida Building Code Online Page 1 of 2 Flora Departr.enta MS Huse I Lop In ; ther RMI-Maition j Hot Topl a Subrnit Sucharge Statb & Faris ) Busines .1" QOUSER: 'PuWkllsffProfessilnal Regulation Product Aonrovel Menu > Hoduct or nolkathn arch A2Q atlon Lim > Applitatfon Detaa FL # L9520-R5 Application Type Revision Code Version 2014 Application Status pproved Comments Archived PUI,Ec4l3d,0 I fMC" I 8=61taMap I LM13 I t5i ith ! Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 352) 368-6922 ekoss@cws.cc Authorized Signature Koss Erin ekoss@cws.cc Technical Representative Erin Koss Address/Phone/Emall 1900 SW 44th Ave. Ocala, FL 34474 352)368-6922 Ext291 ekoss@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Emall 1900 SW 44th Ave. Ocala, FL 34474 352)368-6922 Ext291 jlathrop@cws.cc Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Wl Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equlvalence of Product Standards Certified By Lucas A. Turner PE-58201 Keystone Certifications, Inc. 04/10/2016 Steven M. Urlch, PE F6 Validation Checklist - Hardcopy Received Standard AAMA 450-06 ASTM E1886-05 ASTM E1996-09 PA TAS 201/2021203 Year 2006 2005 2009 1994 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvIHvmuJRWcZ... 6/25/2015 WON h Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 04/28/2015 04/29/2015 05/06/2015 06/23/2015 PL # Model, Number or Name Description 9520.1 3" Alum. Tube Mullion 3" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use In HVHZ: Yes R-9520 R5 I1 CWS-836A (3 in Mull. IMP).Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 582D1 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520 R5 AE EvalRep CWS-836A (3 in Mull. IMP).Ddf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.2 4" Alum. Tube Mullion 4" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. (IMPACT) Limits of Use installation Instructions Approved for use in HVHZ: Yes FL9520 R5 II CWS-837A (4 in Mull. IMP).Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520 R5 AE EvalRep CWS-837A (4 in Mull. IMP).pdf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.3 5 1/2' Alum. Tube Mullion 5 1/2" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9520 R5 Il CWS-838A (5.5 in Mull. IMP).Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure[ N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520 R5 AE EvalRep CWS-838A (5.5 In Mull, IMP).Ddf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. amdt Nett Contact Us:: 1940 North Monroe Street. Tallahassee FL 32399 Phone: aEh487-1824 The State of Florida Is an AA/EEO employer. copyright 2007-2013 State of Florida.:: PrIvaLy Statement :: Accessibility Steneine :: Refund Statement under nolda law, emaa addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, rsrct the office by phone or by traditional mall. If you have any questions, please contact 850.487.1995. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees resnsed under Chapter455, F.S. must provide the Department with an emal address If they have one. The emals provided may be used for oftklal communication with the tcensee. However anal addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made avarabie to the public. To determine if you are a licensee under chapter 455, F.S., please click IIC6' Product Approval Aooeptsi DE sacurimmi imv% http:// www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvIHvmuJRW cZ... 6/25/2015 9520. 2 4" Alum. Tube Mullion 4" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. ( IMPACT) Limits of Use installation Instructions Approved for use in HVHZ: Yes FL9520 R5 II CWS-837A (4 in Mull. IMP).Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520 R5 AE EvalRep CWS-837A (4 in Mull. IMP).pdf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520. 3 5 1/2' Alum. Tube Mullion 5 1/2" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9520 R5 Il CWS-838A (5.5 in Mull. IMP).Ddf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure[ N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520 R5 AE EvalRep CWS-838A (5.5 In Mull, IMP).Ddf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. amdt Nett Contact Us:: 1940 North Monroe Street. Tallahassee FL 32399 Phone: aEh487-1824 The State of Florida Is an AA/EEO employer. copyright 2007-2013 State of Florida.:: PrIvaLy Statement :: Accessibility Steneine :: Refund Statement under nolda law, emaa addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, rsrct the office by phone or by traditional mall. If you have any questions, please contact 850.487.1995. *Pursuant to Section 455. 275(1), Florida Statutes, effective October 1, 2012, licensees resnsed under Chapter455, F.S. must provide the Department with an emal address If they have one. The emals provided may be used for oftklal communication with the tcensee. However anal addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made avarabie to the public. To determine if you are a licensee under chapter 455, F.S., please click IIC6' Product Approval Aooeptsi DE sacurimmi imv% http://www. floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvIHvmuJRW cZ... 6/25/2015 URNER ENGINEERING & CONSULTING. INC. Product Description: PVC 3" Mullion H-1758 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 836A April 27, 2015 Manufacturer: Custom Window Systems, Inc. 1900 SW 44 h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 5"' Edition (2014) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by "Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-836A, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3833-1, -1A, -2, -2A, -3, and -3A, from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E. a. Testing Performed: TAS 201/202/203-94, ASTM E 1886-02/04/05, ASTM E 1996-04/06/09, and AAMA 450-06 4) Supplemental Calcs. to support CWS-836A, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-836A. Limitations of Use: This product: May be used up to the sizes and design pressures as shown in CWS-836A, using clips as shown in CWS-836A Is Large Missile Impact Resistant and does not require the use of shutters May be used in the High Velocity Hurricane Zone May only be used with Custom Window System, Inc. windows, please see separate individual window unit approvals for applicable design pressures and for more details. The lower of the individual window design pressures and the mullion design pressures shall apply to the entire assembly. Requires 6063-T6 aluminum mullion and clip extrusions. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a fmancial interest in any other entity involved in the testing or approval process of this product. P 10RE4y' lGEfVs'•G's No 58201 f- 4/27/2015 srA7 of : ;* Lucas A. Turner, P.E. S9-% O. FL PE #58201 0 /Or4 ' ' Lucas A. Turner 2015-04-27 21:00-04:00 W/DIFFERENT EXAMPLE HORIZ/.VERT. MULLION FOR SECTION VIEW ONLY TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS-..._..._...1 DP CHARTS.___ ........................ ..... ........... 2-3 BOM & EXTRUSIONS ..... _... __.................... A EXTRUSIONS...._ ....................... _................ 5 SECTION VIEWS .............. _......................... 6.7 CONFIGURATIONS & ANCHOR NOTES INSTALLATION DETAILS ..........................9-10 CLIP ANCHOR C4W GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC). CURRENT EDITION INCLUDING THE HIGH WINDC"SYSTEM VELOCITY HURRICANE ZONE PWKZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL 1900 SW 44TH AVE. D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. OCALA. FLORIDA 34474 W W W.CWS.CC 2. CONFIGURATIONS (SEE SHEETS 2.3): VERTICAL OR HORIZONTAL 3_ SEE MULLION CHARTS FOR MAX DESIGN PRESSURES AND LENGTH. 3^ PVCREFERTOSHEETS2-3) MULL BAR 4. ANCHORAGE: THE 331/3% STRESS INCREASE HAS NOT BEEN USED IN THE IMPACTDESIGNOFTHISPRODUCT. SEE SHEETS 9-10 FOR ANCHOR DETAILS. WI NDLOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. a S. DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS. y 7. DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT u APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL B. RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFTEY REQUIREMENTS RESTS SOLEYWITH THE ARCHITECT, ENGINEER OF RECORD, BUILDING OWNER OR CONTRACTOR. a 9. SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS C a DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY CUSTOM WINDOW SYSTEMS, INC. AND MUST BE MADE OUT OF VINYL PVC OR EXTRUDED ALUMINUM. q 10. VERTICAL MULLED UNITS MAY BE MUTED INDEFINITELY AS LONG AS THE SINGLE UNIT WIDTH AND HEIQHTARE NOT EXCEEDED, AND MULLIONS ARE ANCHORED AS SHOWN HER N. gfiSWOREw 1,G 11. HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT j VERTICAL MULLION IS USED TO MILL SIDE BY SIDE UNITS TOGETHER. z' No 58401 0 ri EXAMPLE VERTICAL MULLION FOR PVC WINDOWS FOR SECTION VIEWS ONLY Lucas A. Tumer 2015-04-27 21:00-04:00 LUCAS A. TURNER, P.E. FL PE # 58=1 1239.IABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 NIO z GENERAL NOTES AND ELEVATIONS AWNft bxw..— ADE 09/27/12 CW S-836 A ALE SHEET 125 1 OF10 or Ka,F e 42 314 W.0E183O. 8D.0 80.0 80.0 8D.0 60.0 80.0 48 314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 g 63118 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 63 8D.080.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 65.0 65.0 65.0 65. 65.0 65.0 65.0 65.0 65.0 65.0 72 65.0 1 65.0 65.0 1 65.0 65.0 65.0 65.0 64.9 DP CHART IS FOR: NON -INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING (PER END): 1522 CUPS 4) #10 SCREWS INTO WOOD or METAL 4) 3116' ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD 4) IW ELCO ULTRACONS INTO HOLLOW or GROUT -FILLED BLOCK ULTRACONS, pact PVC 3" Mullion H-1758, with 1776 clps wfth six (6) #tD Screws Into WOOD or METAL or 3r16" rTW Tapcons or ELCOULTRACONS Into SOLID CO C ETE ar WOOD per each end of mullion. HOLLOW or GROUT-FII I BLOCK r"uiro 1/4' ELCO ULTRACONS. OPEMgp SIZE (In.) 63 69 76318 81 87 93 1 99 1 1073/8 1 114 1 19p I 1gn I ia- I iaa I,we ero c 42 314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 48 314 80.0 00.0 80.0 90.0 80.0 80.0 00.0 80.0 631/ 8 80.0 80.0 80.0 BD.0 80.0 80.0 80.0 80.0 57 SD.0 60.0 80.0 80.0 80.0 80.0 00.0 80.0 63 80.0 00.0 8D.0 8D.0 8D.0 8D.0 8D.0 80.0 j 66 65.0 65.0 65.0 B5.0 65.0 65.0 85.0 65.0 Z 68 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 72 65.0 65.0 1 65.0 1 65.0 65.0 65.0 85.0 64.9 DP CHART IS FOR: NON - INTERSECTED IMPACT 3" MULLON 1758, HORIZONTAL OR VERTICAL, USING (PER END): 1776 CLIPS 6) # 10 SCREWS INTO WOOD or METAL 6) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD 6) 1/4' ELCO ULTRACONS INTO HOLLOW or GROUT FILLED BLOCK OPENING TRIPLE VERTICAL MULLION z 3 I LI II I OPENING SIZE F - TRANSOM OVER TRIPLE VERTICAL MULLION NOTES: 1. THE MULLBAR IN FOCUS FOR ANY GNEN CONFIGURATION IS SHOWN IN BOLD, 2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. 3. NON - INTERSECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS. TWIN TRIPLE TwDMPLE HOROMMALANU.IDNHOREMWALMLumHORIZONTALIAKLIONdOPENING rn SIZEL z ki 0 muLL LENGTH - 4 7 -MULLLENGTH -Z1 MULL LENGTH 4. WINDO"MnM IWDSW 44TH AVE. OCALA, FLORIDA3"74 W W W. CWS.CC 3" PVC MULL BAR IMPACT No 58401 STATE OR LUCASA TURNER,P. E FL PEN 50201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380- 1574 SHEET DEaCAIPTION: DP CHARTS NON - INTERSECTED ADE 09/27/ 12 CWS-836 p SHEET 1:1 2 OF 10 Pressure Chart (PSF) for INTERSECTED bpact PVC 3' Ilion H-1758, with 1522 dips using tour (4) B10 Screws Into V40OD or METAL or 16' apcona Into SOLID CONCRETE or WOOD, or 17 with six (6) I10 Screws Into WOOD or METAL or 311 6"ITW Tapcons Into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW arGROUT-FILLED BLOCK rowire 1 /4" ELCO ULTRACONS. 37 50.0 50.0 50.0 50.0 60.0 50.0 50.0 50.0 50.0 50.0 60.0 50.0 50.0 50.0 50.0 I" 1 50.0 ioo 50.0 I 1w V* 50.0 1900 SW 44TH AVE. OCALA, FLORIDAS447424231450.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 60.0 5D.0 50.0 50.0 50.0 50.0 50,0 50.0 WWW.CWS.CC 48 314 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 60.0 50.0 50.0 50.0 50.0 60.0 50.0 60.0 531/8 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.6 50.0 60.0 50.0 60.0 50.0 60.0 50.0 50.0 50.0 50.0 PVC5750.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48.1 3" W7 MULL BAR6350.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.4 47.3 IMPACT6650.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.6 a e t - 72 50.0 50.0 50.0 Sa.O 50.0 50.0 56.0 50.0 50.0 50.0 5o.a 46.4. 44.n r _ •< a DP CHART IS FOR: INTERSECTED IMPACT 3" MULLION 1758. HORIZONTAL OR VERTICAL, US)NG EITHER (PER END): 1522 CUPS p Y m4) 410 SCREWS INTO WOOD or METAL 4) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD 4) 1/4- ELCO ULTRACONS INTO HOLLOW of GROUT -FILLED BLOCK 1767 CUPS a 6) #10 SCREWS INTO WOOD or METAL 6) 3/16" n1N TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD a F 6) 1/4' ELCO ULTRACONS INTO HOLLOW or GROUT -FILLED BLOCK o o nywRr`LE HORIZONTALMULLK84 VERTICALMULLION T- ISINGLEI w TWIN OR I ITRIPLEI UNITS I II ( BELOW( OPENM SIZE -+1 Fes- MULL LENGTH --- NOTES: 1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION ISS14OWN IN BOLD. 2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CUPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT aOTH ENDS. 3. NON -INTERSECTED MULL BARS CAN BE ATTACHED TOTHE SUBSTRATE AND OTHER MULL BARS, LUCAS A. TURNER. P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 DP CHART INTERSECTED MULLS N N . ADE 09/27/12 Vol: . CWS-836 A SHEET 1:1 3 OF 10 PART 0 DESCRIPTION LINE ITEMS NOT USED: 5.6, 12 FRAMETYPE FLANGE FIN BOX OPENINQ NEW RETRO RETRO RETRO NEW RETRO r MULLBAR CLIP 162Z-X F-1522-013 F-1522 006 F-1522.013 F-1522-013 NOTRECOMMENDED F-1522-008 U' MLILLEAR CUP F17B7-"m F 1767-001 F 1767-001 F-1767-004(LAR) F-1767.004(LAR) F-1767-M F-1767.OM WINK SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW'CWS'cC. H-1758 1 3/8" x T MULLION TUBE 410 OR #12 HEX WASHER HEAD TEK SCREW •Soo note 10 x 1 1/2', PANHEAD PHILIPS 2INC 10 FIAT WAS 5-1897 MULLION CUP SEALANT SAM DRIP CAP T, PVC. MULL BAR IMPACT S-1898 FLANGE ADAPTER 018 MULLION INTERIOR ER P-3488 MULL BAR CAP 15M-013 3- SLOTTED NEW CONTRUCTION FIN MULL CUP:9 USE WOOD SCREW SRP (e10 OR 312), SPECIFIED IN WINDOW UNITAPPROVAL DOCU4ENi 13/4"--"j 1 11/18' Edi~ I-17/16'17/IG+{ 7/18" I I 1/Y I I 11 1 1 1 9 7!1 G 1118- MULLION INTERIOR 1l18" DRIP CAP 8.1895 113V16 1.. f11b/141 113/16" y8• COVER S•6018 FLANGE ADAPTER S-1896 I 11 3/16" I Q 1 3/8" 13i18• I II I TOP VIEWLo213/16"1/8- O 13116, 1Ai3"MULLBAR H•1758 .ILL MULLION Cup 8-1897 1JI A / SCORE, BEND AND BREAK TO REMOVE FIN FOR FRAME ATTACHEMENT TO MULL BAR DETAIL A TYP. FIN FRAME 3:1 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-To UNLESS OTHERWISE NOTED. 0 114 1 2 1L 4" 1/8" 4 71W F 1522- 013 NEW CONSTRUCTION / FIN INSTALLATION 1 2,Mr L 1f8I' F-1522.008 RETRO / FLANGE CUP LUCAS A. TURNER, P.E. FL P E 4 58201 1239 JABARA AV E. NORTH PORT, FL 34288 PH. 941-380-1 S74 BOM AND EXTRUSIONS ADE 1 09/27/12 CWS-836 A SHEET 1:2 4 OF 10 FRAME TYPE OPEPBNR "T" MULL9AR CLIP L" NU ) CLIP 1522-XXX 1787-X67-XXX) mm-mmmmFLANGE IOW F-1522-013 F-1767-001 WE RETRO F-1522-OOS F-1767-001 19M SW 44TH AVE, F-1522-013 FIN F-1767.004(L$R) OCALA, FLORIDA 34474 RETRO RETRO F-1522-013 F-1767.0040H) VMW.OWS.CC BOX NEW NOTRECOMMENDED F-1787-001 REMO F4522-OD6 F-1767-M T, Pvc MULL BAR IMPACT 1 e a o Y Ili m 2 3/4' 2 114• tDZ Q 16I6" 123(4") 27/16' g 0 cr o a 5c5c Inc THRu trvPl 1/a" THRU (1YP) 11T g OUT6IDE 1/4 (IYP) VIG' (TYP) 3` ttttgtnufffyf GEN 1ti4 OY aw CD JGPr• v : NO 511201 L 1 123/49 15t0' 901 STATE OF 1,4U hifhkAiti filt/8° 12• if2' I 67fB" 4272015 LUCAS A. TURNER, P.E. FL PE # 58201 23l4' 2 3/4• •L" ANGLE 3" STANDARD MULL CLIP - F-1767-001 1239 JABARA AVE. L- ANGLE 3" MULLCUP, FAY (LEFT) F-1767.004L 'L" ANGLE 3• MULL CUP, FIN (RMT) N1767-004R I NORTH PORT, FL34288 PH. 941-380-1574 OU761DE 6HEET DEBCRIPTIDH: EXTRUSIONS UPAWN BY. ADE DATE: 0927/12 vivo$: mv.: GWS-836 A SHEET 12 5 OF 10 1 HORIZONTAL MULL BAR SECTION U FLANGE FRAME WINDOW SEAL BEHIND FLANGE--v 1® (SEE DETAIL B) PRIOR TO ATTACHING TO MULLION 1VERTICAL_MULL BAR SECTION JFLANGE FRAME WINDOW SEAL BEHIND FLANGE PRIOR TO ATTACHING TOMULLION FIN MUST BE REMOVED WHERE WINDOWS CONNECT TO MULL ai HORIZONTAL MULL BAR SECTION 6 F1N FRAME WINDOW RN MUST BE REMOVED WHERE WINDOWS CONNECT TO MULL APPLY SEALANT ALONG R. LENGTH OF WINDOW FRAM GROOVE PRIOR TO ATTACHII GO% A VERTICALIHOR ZONTAL MULL BAR SECTION e BOX FRAME WINDOW APPLY SEALANT LENGTHNGRILL GROOVEPRIOR 4n r-- ADAPTOR I EIS r1 1 0 1 1 DWAILA SEAL BEHIND RANGE—v (SEE DETAIL B) PRIORTOATTACHINGTO MULLION ZVERTICAL MULL BAR SECTION 6QFIN FRAME WINDOW I I APPLY SEALANT ALONG FULL I LENGTH OF MLILLBAR GROOVE PRIOR TO ATTACHING FLANGE ADAPTOR I N I 1 d L DETAIL B wltvoc NrsrsrEMI LL 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW. CWS.CC 3" PVC MULL BAR IMPACT 4/ 27/2015 LUCASA. TURNER, P.E. FL PE #i 58201 1239 JABARA AVE NORTH PORT, FL 34288 PH. 941-380.1574 EET : SECTION VIEWS MULLS AWN BY. A E: ADE D9/27/12 Q 4. .. CWS- B38 A SHEET 1 : 2 6 OF 10 TOP VIEW FIN FRAME 5' MULLBAR (Ft 176M SEE SEPARATE APPROVAL FOR APPROPRIATE DP CHARTS) 4' MULLBAR (H•1759) SEE SEPARATE APPROVAL FOR PROPRIATE DP CHARTS) SEE NOTE 1 7 1III MAX EDGE DISTANCE SEE NOTE 1 7 11116- MAX EDGE DISTANCE t t 1 1 1 SEE NOTES 1 A 2 19 SEE NOTES 1 S 2 SEE NOTE 4 (1 EAJCLIP) SEE NOTE 4 ( 1 FA/CLIP) 5';EM TO 3- VERT. NIULLBAR SECTION C 4' HORIL TO 3' VERT. MU LBAR SECTION 7 E FRAM 7 SEE NOTE 1 SECTION VIEW A -A 11118_ MAX EpGE DISTANCE 190D SW 44TH AVE. OCALA. FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR IMPACT v l 11 I I I U 19 SEE NOTES 1 8 21EAJCLW) zr SEE NOTE 4 4/27/2015 LUCAS A. TURNER, P.E. c 3• NORM TO 3' VERT. MULLBAR SECTION 7 FL PE # 58201 1239 JABARA AVE NOjgS: NORTH PORT, FL 34288 PH. 941-380.1574 1. SLIDE CUP INTO LOCATION AND SECURE WITH 1T19dS 19 (OTY 1) AND 20 (OTY 1). AS SHOWN ABOVE. 2. PREDRILLED HOLES(MW W CLIP 1897). BY THE INSTALLER, MAYBE LOCATED AS NEEDED WHILE MA1NTMNING A MINMUM CUP EDGE DISTANCE SECTION VIEWS MULL INTERSECTIONS OF OW AND A MINIMUM CENTER TO CENTER SPACING OF I tr. 3. THE ABOVE SECTIONS APPLY TO ALL MULLBAR TO•MULLBAR CONNECTIONS, AOE 09/27/12 REGARDLESS OF ORIENTATION (I.e., HORIZONTAL OR VERTICAL). THE FULL LENGTH v. CWS-838 v.. A MULL MUST BE THE SAME DEPTH, OR GREATER, THAN THE INTERSECTING MULL 4. INTERIOR MULL ANCHOR ATTACHMENT SCREW THRU VERTICAL MULL INTO MULL Z5 LF- SHEETSHEETCLIP. PRE -DRILL PILOT HOLE THRU ALL MATERIAL 1,2 7 f Ed O TWIN VERTICAL MULLION c7 TRIPLE TRANSOM OVER TWIN VERTICALMULLION VERTICALMULLION OPENING SIZE--- —. OPENINGSIZE F F--- TWIN TRIPLE TMNRRIPLE HORIZONTAL MULLION HORIZONTAL MULLION HORIZONTAL MULLION y m MULL LENGTH —.4 f --MULL LENGTH OPENING SOE-- TRANSOM OVER TRIPLE VERTICAL MULLION oPSNwn cvc NOTES: 1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD. 2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO TT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CUPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS, 3. NON44TEMECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS. TWIN/TRIPLE HORIZONTAL MULLION VERTICAL MULLION T w m I51 Z I TWIN I ] I I LBELOW OPNINGSZ" MULLLENG TH— NOTES: 1. AT MULLION LOCATION, ATTACH WINDOW UNITS) TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS. IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL DOCUMENTS, FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE, USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE (#10 OR #12) AS THE WOODSCREWINDICATEDINTHEWINDOWAPPR(VAL. TEK SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE (3) THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 2. MULL CUP INSTALLATION ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS. SEE TABLE 1. SHEET 9. 3. ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOODMUSTBEPROTECTEDTOPREVENTREACTION_ 4. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUMSPECIFIEDINTABLE1, SHEET 9. 5. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETEICMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE -1X BUCKS AREOPTIONALS. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE -DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4.5. 7. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BYTHE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATESSHALLMEETTHEMINIMUMSTRENGTHREQUIREMENTSASSHOWNINTABLET, SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. S. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMAIOO(FINWINDOWS),FMA/AAMA2D0(FLANGEWINDOWS), FMA/WDMA250(BOXWINDOWS),FMA/AAMA/WDMA30o(EXTERIORDOORS) 1900 SW 44TH AVE. OCALA. FLORIDA 34474 W WW.CWS.CC T, PVC MULL BAR IMPACT LUCAS A. TURNER, P.E. FL PE $ 582DT 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 CONFIGURATIONS AND ANCHORAGE NOTES ADE I OB/27/12 DWG 9: CWS- 636 A SHEET 1: 1 8 OF 10 t BAR CUP L' ANGLE MULL BAR CLIP TWO REOfl PER EACH END OFMU.L MULL BAR wn3ow "mTea 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W WW.CWS.CC 3" PVC MULL BAR IMPACT ANCHOR t -: j— w,7r!— ANCHORSEETABLE 1SEALANTALONGSEETINSTABLEALLATION ADOMUCTURALELEMENTS AS REO'D TO MAKE LEVEL FOR SEALANT ALONG I ADD STRUCTURALELELTNTS OUTSIDE EXPOSED MULL BAR OUTSIDE EXP09ED AS READ TO MAKE LEVEL FDR EDGE BY IN3TALLER EDGE BY INSTALLER MULL BARPERIMETERINSTALLATIONSEALANTPERIMETER8EALANT BY INSTALLER INSIDE AND OUT Mt:7J78EE BY INSTALLER INSIDE AND OUT MR EMBEDMENT cTAABBLESEETABLE1 AEIBYOTHERB SUBSTRATE BY OTHERSSEEBTSEETABLE1 QMIN. EDGE DIST. MRJ. EDGE DIST. SEE TABLE 1 SEE TABLE 1 VERTICAL E VERTICALSECTION 0 TYPICAL FLANGE (RETRO FIT) ANCHORAGE B TYPICAL F('LRANGE ' ANGLE) ANCHORAGE pna gptiOREIyHEADANDJAMBSSIMILARFORFLANGEINSTALLATIONHEADANDJAMBSSMIILARFORFLANGEINSTALLATIONTGi TABLE 1: APPROVED MULL CUP INSTALLATION FASTENERS UBSTRATETYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE MST. CONCRETE (20 KSI MIN.) 3/16' RW TAPCON 1• 31 CONCRETE (ZSS KSI MIN.) 3/16' ELOO ULTRAOON 1-3W 1' HOLLOW or GROUT -FILLED CMU (ASTM C-90) 1/4" ELCO ULTRACON 1-1/4' 2.1/2' 2XMIN. SOUTHERN PINE (G 0.55) 3116" RW TAPCON OR ELOO LILTRACON 1 g• 7/8" 2XMIN. SOUTHERN PINE (G-0.55) 810 WOOD SCREW 1-16' 7/6' 16GALIGE(0.060')MIN.STEEL STUD 33 KSIYIELD MM 10-16HTLTIKWK-FLEX ORITW TEKS SELF-DRI UN(3 SCREW FULL THREAD THRU 0.060' 7n6' 1/8" ALUM. P63-TS MR) OR 1/8" STEEL (33 KSI MIN.) 10 GRADE 5 SELF TAPPNG / DRILLNG SCREW FULL THREAD THRU 0.125' 7/1B z z 4/27/2015 NOTES: LUCAS A. TURNER, P.E. I. BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME, FL PE N 58201 1239 JABARA AVE. 2. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT, FL 34288 AFTER INSTALLATION. PH. 941-380-1574 3. RECESS RETRO MULLION CUP 3B" MAX. FOR CLEARANCE OF WINDOW SHEET o UNITAS NEEDED. INSTALLATION DETAILS FLANGE 4. FOUR (4) ANCHORS REQUIRED PER T MULLCLIP, SEE SHEETS 23. DRAWN UY. DA-[F-' THREE (3) ANCHORS REQUIRED PER -L' MULL CLIP, SEE SHEETS 2.3. ADE 09/27/12 5 SEAT MULLION TIGHT TO MULL CUP. DWG#: NEV.-- 6. FOR ANCHORAGE DETAILS FOR THE WINDOW. REFER TO THE WINDOW CWS-836 A SPECIFIC INSTALLATION DETAILS. SHEET 1:2 9 OF 10 RETRO FIT MULL BAR CUP i MULL BAR TINSTALLATION ANCHOR SEE TABLE 1, BHT 9 BEALANTALONGE OUTSIDE EXPOSED ed4EDGEBYINSTALLER EXTERIOR FINISH o• MIN. EMBEDMENT BY OTHERS L$i = - = SEETASLEI.SHT9 PERIMETER SEALANT BY INSTALL6I INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, BHT 9 MIN. EDGE DIST. 1 VERTICAL SECTION SEE TABLE 1, BHT 9 10 TYPICAL FIN (RETRO FIT) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR IMPACT V ANGLE CUP TWO REO'D PER EACH END OF MULL f(1 MULL BAR Y INSTALLATION ANCHOR SEE TABLE 1, SHT B aa SEALANTALONGE OUTSIDE EXPOSED 4; EDGE BY INSTALLER e•• w EXTERIOR FINISH MIN. EMBEDMENT aBYOTHERS44SEETABLE1, BHT 9 PERIMETER SEALANT SQ BY INSTALLER ° ti INSIDE AND OUT d SUBSTRATE BY OTHERS ttttttlJgJJtSEETABLE1, BHT 9 MIN. EDGE DIST. Pp°r.•"oEiv rGF' rG-1 VERTICAL SECTION SEE TABLE 1, BHT p f• 20J TYPICAL FIN (•L' ANGLE) ANCHORAGE Ji : No 582D1 ' HEAD AND JAMBS SIMILAR FOR RN INSTALLATION NOTES: 1. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS AFTER INSTALLATION. P- RECESS RETRO MULLION CLIP 3/8' MAX FOR CLEARANCE OF WINDOW UNITAS NEEDED. 3. FOUR (4) ANCHORS REQUIRED PER MULL CUP, SEE SHEETS 2-3. THREE (3) ANCHORS REQUIRED PER -V MULL CLIP, SEE SHEETS 2-3. 4. SEAT MULLION TIGHT TO MULL CUP. S. FOR'ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW SPECIFIC INSTALLATION DETAILS. 4127/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JASARA AVE NORTH PORT, FL 34288 PH. 841 380-1574 Pffer . INSTALLATION DETAILS FIN ADE 09/E7/12 V.: CWS-836 A SHEET 1:2 10OF10 1 Florida Building Code Online Page 1 of 2 I - TAMMG Fbfida Dzpartlrlerltq aclS Home I Lop In 1 User Registration i Hot Topla Businesf]{j j(? 4=1k; Product ApprovalProfessiVC1IPublicUser Regulation 4110 E y vF 1. Subntt Surcharge I stats @ Facts I PUNrAtiom I MC S1311? I eta SM Map I Link I Sorch j Product Anaoval Menu > Prod uY a AnolltaUon ti > Amfflotbn List > Application D®tall r3 FL # FL11103-R2 Application Type Code Version Application Status UApproved Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Emall 1900 SW 44th Avenue Ocala, FL 34474 352) 368-6922 ekoss0cws.cc Authorized Signature Koss Erin ekoss0cws.cc Technical Representative Erin Koss Address/Phone/Emall 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 ekoss@cws.cc Quality Assurance Representative ay Lathrop Address/Phone/Emall 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext291 jlathropocws.cc Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or'M Licensed Florida Professional Engineer 66 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE R Validation Checklist - Hardcopy Received 244, 1 1r . L . •cr .. Standard AAMA/WDMA/CSA 101/I.S.2/A440-05 ASTM E1300-04 ASTM E1886-02 ASTM E1996-02 TAS 201/202/203 Year 2005 2004 2002 2002 1994 http://www.floridabuilding.org/car/pr app_dt].aspx?param=wGEVXQwtDgttaGsIp3GvutO... 6/24/2015 Florida Building Code Online w Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 04/20/2015 04/23/2015 04/25/2015 06/23/2015 FL # Model, Number or Name Description 11103.1 SGD-8900 PVC Sliding Glass Door. SGD-8900 PVC Sliding Glass Door. Limits of Use Installation Ird*uctlons Approved for use In HVHZ: Yes FL11103 R2 I1 CWS-298B (SGD-8900, IMP),odf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: Large Missile, DP - +/- 60 psf, Max. panel size 4' x Fj,11103 R2 AE DuPont SGP NOA 11-0624 02.odf FL11103 R2 AE EvalReD CWS-298B (SGD-8900. IMP).vdf8'. ConfIg. Include OXXO, OXO, OX, XO. Glass compiles to ASTM E3300-04, FL11103 R2 AE Ouanex (Mikron) NOA 12-1017 02,odf Created by Independent Third Party: Yes back Nee Contact Us :: 1910 North Monroe Street. Tallehascee FL 32399 Phone: B50.487-1824 The state of Florida Is an AMEED employer. Coovrtoht 2007-2013 Slate of Florida.:: Privacy Stateme :: A=sfbftty Statprrignt :: gj6,lpd Under Florida kw, email addresses are putdk records. it you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by tradMoml mail. If you have any, questions, please contact 850.4117.1395. *Pursuant to Section 455.275(i), Florida statutes, effective October 1, 2012, kensees licensed under chapter 455, F.S. must provide the Department with an email address B they have one. The emells provided may be used for ofnclad communication with the licensee. However email addresses are pubes record. If you do not wish to supply a personal address, please provide the Department with an email address which an be made available to the public To determine If you are a Ikensee under CTapter455, F.S., please didchaL. Product Approval Accepts secvritvslt rrttm- http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgttaGslp3GvutO... 6/24/2015 URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 298B April 18, 2015 Product Description: Series 8900 PVC Sliding Glass Door, LM Impact, 4'x8' nominal panel size max. Manufacturer: Custom Window Systems, Inc. 1900 SW 44'h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 5t` Edition (2014) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-298B, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3506-1 and -1A, from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E. a. Testing Performed: TAS 201/202/203 1994, AAMA/WDMA/CSA I Ol/I.S.2/A440-2005, and ASTM E 1886/1996 2002 4) Supplemental Calcs. to support CWS-298B, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-298B. Limitations of Use: This product: May be used in up to 48 7/8" x 93 1/2" panel sizes (96" max. door height), with glass types and max. glass daylight sizes as shown in CWS-298B Achieves design pressures of +/-60 psf Is Large Missile Impact Resistant and does not require the use of shutters May be used in the High Velocity Hurricane Zone Requires Dupont SentryGlas (SGP) Interlayer per Miami -Dade NOA #11-0624.021 Requires Quanex (Mikron) white rigid PVC extrusions per NOA 012-1017.02t t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5'r Ed. (2014) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. DREIV A* r ., No 58201LQ ;. 4/18/2015 s ¢: 06.. STATE 0, Lucas A. Turner, P.E. 4, IFS •.0 o Ft 9.•O, FL PE #58201 Lucas A. Turner T- MAX SITIGHT MAX B PANEL HEIGHT 487/8• IV] I/H MAX UNIT WIDTH MAX PANEL WIDTH A 41314' GLASS DLO XO9s3ff0 GLASSLLilo I 145 13116" MAX UNIT WIDTH 48 7/8- MAX PANEL WIDTH 41 E CLASS g• DLO JNrr EIGHT D G 0 X 0MM3n'x"r PANEL DLO HEIGHT bLL.1 c TABLE OF CONTENTS GENERAL NOTES & ELEVATION.'3..-._....._...-1 SECTION VIEWS OXXO & GLAZING DETAIL_2 SECTION VIEWS OXO & x0_.-,,,,-,3 EXTRUSIONS & ELOJL_..................--..--4 ANCHOR SCHEDULE IS NOTES-..................-,--.5 INSTALLATION DETAILS--- 6 I 9 e C 6 A A 6 96' MAX UNIT WIDTH 48 7/9MAX PANEL WIDTH 41 314' GLASS AAXINIT DLO 1I GHT mAx E PANEL 01 X HEIGHT GLASS a DLO 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TOVVIE 9COMPLYWITHTHEFLORIDABUILDINGCODE (FBC), CURRENT EDITION AND IS RATED FOR IMPACT USE IN W 04D ZONE 4 AND HIGH VELOCITY 1900 SW 44TH AVE. HURRICANE ZONE NVHZ) AREAS AS DEFINED IN ASTM E 1998 PER THE FBC. OCALA, FLORIDA 34474 W W W.CWS.CC 2 GLAZING DETAIL- (SEE SHEET 2) 3. APPROVED GONFIGURATIONS:'OXXO", -OXO', "XO', "OX' 4. DESIGN PRESSURES: NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04. POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE, AND GLASS TABLES ASTM E-130D-04. 5. ANCHORAGE: THE 33113% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET a FOR INSTALLATION DETAIL WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. S. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. 7. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS FULLY WELDED. 8. SERIES / MODEL DESIGNATION: SGO-8900. 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X-OPERABLE SASH, O-FIXED SASH. 10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS. 1. EXTERNAL WEEP SLOT- 114 x 1' LOCATED 4' FROM BOTH ENDS. 1 Lucas A. tTumer E 2015-04-20 12:30-04:00 NFIG. MAX. UNIT SIZE MAX PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING XO 96" x 96" 48-7/8" x 93-1 /2" 60 PSF LARGE MISSILE IMPACT OXO 145-13/16" x 96" 60 PSF LARGE MISSILE IMPACT OXXO 191-1/8" x 96" 60 PSF LARGE MISSILE IMPACT 8900 PVC SLIDING GLASS DOOR - IMPACT No 58201 . P' YI' 3 a STATE OF 4IW2015 LUCAS A. TURNER, P.E. FL PE N 58201 1239 JABARA AVE. NORTH PORT, FL 342BB PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS ADE 1 08/03/08 CWS-298 B SHEET 1 :33.33 1 OF 6 SECTION B-B PAIR OFANCHORS AT EACH CUP. SEE SHT 6 FOR SPACING SECTION C-C FDCED PANEL ATTACHMENT NOTE: INSTALLATION WITH NO SILL RISER ALLOWED ONLY WHERE WATER INFILTRATION RESISTANCE I9 t=REOIRRED. am 1' OVERALL W16' TEMPERED 3/8' AIRSPACE 7M(r LAMMATEDGLASS 3/1W ANNEALED GLASS 090 SENTRY GLASS IONOPLAST INTERLAYER 3116" ANNEALED GLASS PURFECT GLAZE'I-r SIKAFLEX552 13116' GLASS BITE vllNww s rsrEm 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8900 PVC SLIDING GLASS DOOR - IMPACT No 58201 STATE OF zz 41312015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 ,IABARA AV E. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS -OXXO AND GLAZING DETAIL ADE 06/03/08 voA .. CWS-298 B SHEET 1.2.63 2 OF 6 SECTION D-D SECTION E-E 1900 SW 44TH AVE. OCALA, FLORIDA 34474 Www.OWS.CC 8900 PVC SLIDING GLASS DOOR - IMPACT No 50201 STATE OF 4/3/2015 LUCAS A. TURNER, P.E. FL PE S 68201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS - OXO AND X01OX NOTES; ADE 08/03/08 I. ITEMS NOT SHOWN FOR CLARITY.10, 28 2 r. 2. VERTICAL SECTION CAN BE SEEN ON SHEET 2. 1 CWS-298 I B 1 :2•83 1 3 OF 6 5 PVC ASTRAGAL - 6o43 3 5 15/16•-{ O 1 1/8• 2 11n6• min0110j] L - j m PVC OUTER FRAME - 6042 REINF. -1993 3 3 PVC PNL INTERLOCK - 606o PVC PNL LOCKSTILE - 6o59 PVC PNL INTERLOCK - 6033 FRAME CONSTRUCTION WI(SYSTE S 1000 SW 44TH AVE. OCALA. FLORIDA34474 W WW.CWS.CC 8900 PVC SLIDING GLASSFRAMECORNERS SCREWED TOGETHER DOOR - IMPACT 1:10 VENT CONSTRUCTION a yaw VI°i mti a VENTS FULLY WELDED a a I+--- 2 U16• WIWI. I 2 MW 9 3/78• 1l16' 3 1l16• 25/3" 1 18/ 1118' 1/8• 7/3• V 18• PVC INTERLOCK SNAP - 6o61 FIXED PNL CLIP - 4295 FIXED PNL COVER -1597 REINF. - 1775 HIGHRISE - 1737 I3AVK FIN I ULTFIAFAB I I 211/16• Sl1LWAN PVC 21/B` lh8• I----f-5/0• 1/2 1 13 fE — — — I I ! 1/18' L 1 3 d• s/a ,na ROLLER TRACK -1930 Ina- PVC SCREEN ADAPTOR - 6045 SILL THRESH COVER -1764 7PVC WELD SUPPORT - 6046 3' 23' 16' 121111r431a' 7/V 1 1 1 ;i1/4• 0 911 1hG 1h6• 1 1l8' IL 1ns- PVC SCREEN CHANNEL - 8044 PVC TRACK FILLER - 8040 FIXED PNL SUPPORT -1722L— ,ns• PVC SCREEN TRACK - 6041 REINF. - 1726 SPECIFIED. NOTE: ALL EXTRUSIONS ARE ALUMINUM 6D63-T6 UNLESS OTHERWISE PVC GLAZING BEAD - 6037 4/ 312015 LUCAS A. TURNER, P.E. FL PE 9 58201 1239 JABARA AVE. NORTH PORT, FL34266 PH. 941-3W-1574 BOM AND EXTRUSIONS ADE D6mos o . .. CWS- 298 B SHEET 1: 2 40F6 r MAX— TYP) I---t -6• mpl ITYPp-j I MAX O.C. TYPE r---]r MAxO.C. YP) I 4. (Typ) I I I MICHOR uYour NOTES: 1. INSTALL TWO ANCHORS AT EACH LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REO'D AT EACH INSTALLATION ANCHOR USING LOAD REARM SHIMS. MAX ALLOWABLE SHIM STACK TORE 1/4'. USE SHIMS WHERE SPACE GREATER THAN 1/18" IS PRESENT. LOAD BEARING SHIMS 614ALL BECONSTRUCTEDOFHIGHDENSITYPLASTICORBETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET S. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIALOR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTEDTOPREVENTREACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIEDINTABLE1, SHEET6. 5. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TOSOLIDCONCRETEORGROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF IX BUCKS BETWEENTHEPRODUCTANDSUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: r FOR MASONRY. 1• FOR WOOD AND METAL 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATESSHALLMEETTHEMIMMUMSTRENGTHREQUIREMENTSASSHOWNINTABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMAIAAMA100(FIN WINDOWS), FMA/AAMA 2DO(FLANpE WINDOWS), FMAAVDMA 250(BOX WINDOWS), FMA/AAMAAVDMA 300(EXTERIOR DOORS). 1 DDO SW 44TH AVE. OCALA, FLORIDA 34474 WWW. CWS.CC 8900 PVC SLIDING GLASS DOOR - IMPACT Me b6201 w STATE OF z 4/ 3/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-480.1574 ANCHOR SCHEDULE AND NOTES ADE O8/03/08 V. r. a W.. CWS- 298 B SHEET 1: 20 5 OF 6 TYPICAL HEAD ANCHORAGE v 2 7/1 r MIN. MIN. EDGE DIST. SEE TABLE t 1/4 MAX SHIM. INTERbR MIN. EMBEDMENT SEE TABLE 1 SUBSTRATE BY OTHERS MIN. EMBEDMENT SEE TABLE 1 SEE TABLE 1 PERIMETER SEALANT- EALANT 1/4" MAX. SHIMBYINSTALLER INSIDE AND OUT 27ne• MIN. INT'EAIOR INSTALLATION ANCHOR SEE TABLE 1 MN. EDGE DIST. SEAL NT BETWEEN SILL RISER AND FRAME SEE TABLE t 1111 ILNI BY INSTALLER PERIMETER SEALANT BY INSTALLER PERIMETER SEALANT O INSIDE AND OLIT SUBSTRATEBYINSTALLER INSIDE AND OUT BY OTHERS SEE TABLE 1 DO NOT COVER WEEP HOLES B HORIDDNTAL SECTION MIN. EMBEDMENT 6 TYPICAL JAMS ANCHORAGE SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 SEALANT UNDER SCREW 27/78- MIN. EDGE DIST. HEAD BY INSTALLER SEE TABLE 1 A1 VERTICAL SECTION 8 TYPICAL SILL ANCHORAGE2 TABLE 1: APPROVED INSTALLATION FASTENERS SUB9TRATE E DIST. 20 KSI MN.) TAPCON 1" CONHOLLOW OR GROUr+I. ED CMU (117 PCF MPL) F31111. ITW TRW TAPCON1" HOLLOW 7ORGROUT -FILLED CMU (ASTM C-80) ELCO ULTRACON 1-1/4" 2-1/22XMIN. SOUTHERN PNE (G=D.55) RW TAPCON t 31T2XMN. SOUTHERN PNE (G-0.55) OOD SCREW 16 GAUGE (0.0W) MIN, STEEL STUD A10-16 HLTI KW 84FLEX OR ITW FULL THREAD 33 KSI YIELD MN) TEKS SELF-DRAIM SCREW THRU 0,06 7/18' 11W ALA1M. (6083-15 MIN.) OR 10 GRADE 5 SELF TAPPING / FULLTHREAD 118" STEEL (33 KSI MIN.) DRtU_M SCREW THRU 0.125' 7/16 FDED AN ANCHORS INTO: CONCRETE ( 2.0 KSI MIN) OR 3/1(" ITW TAPCON 1" 3" HOLLOW OR GROUT+ILLED CMU 117 PCF MN.) FIXED PANEL CUP ANCHORS INTO: CONCRETE ( 2.85 KSI MIN.) OR r3/16- ELOO ULTRACON 1-1/4' 2-3/2" HOLLOW OR GROUT -FILLED CMU ASTM 0-90 INSTALLATION ANCHOR SEE TABLE 1 TWO ANCHORS PER FIXED CUP THROUGH PRE - DRILLED HOLES 1/ 4" MAX SHIM FIXEDPANEL MIN. EMBEDMENT SEE TABLE 1 1r 7 7/ Ir a MAX O. C. FIXED PANEL CLIP CLIP ANCHORS MUST BE LOCATED A MIN r&A NDISTANCE OF3" AWAY FROM ANY MAINFRAME ANCHOR. INSTALLATION ANCHOR OYP) LC. , HORIZONTAL SECTION FIXED PANEL CUP DETAIL 8 FIXED PANEL ANCHORAGE NOTE: FIXED PANEL CLIP ANCHORS INTO WOOD OR METAL SHALL FOLLOW THE ANCHOR TYPE, MIN, EMBEDMENT AND MIN. EDGE DISTANCE LISTED IN TABLE 1. L r 1000 SW 44TH AVE. OCALA. FLORIDA 34474 WwW.CwS, CC 8900 PVC SLIDING GLASS DOOR - IMPACT 4/3/ 2015 LUCAS A. TURNER, P.E. FL PE A 58201 1239 JABARA AVE. NORTH FORT, FL 3426E PH. 941- 380-1574 GENERAL NOTES AND ELEVATIONS ADE 08/ 03/0S a: v.: CWS-298 8 SHEET 1: 2. 67 S OF S