HomeMy WebLinkAbout225 W Seminole Blvd (2)CITY OF SANFORD
JAN 2 8 2616 BUILDING & FIRE PREVENTION
F D
PERMIT APPLICATION
Application No:
Documented Construction Value: $ 1,025.00
Job Address: 225 W. Seminole Blvd., Unit 211 Historic District: Yes No [2
Parcel ID: 25-19-30-520-0100-1211 Residential 0 Commercial
Type of Work: New 0 Addition Alteration Repair Demo Change of Use Move
Description of Work: screen enclosure at entry lanai
Plan Review Contact Person: Don Geissler, Jr Title: President
Phone: 407 461-9929 Fag: 407 365-3194 Email: sunstatesiding@aol.com
Property Owner Information
Name Judy Dennis
Street: 225 W. Seminole Blvd., Unit 211
City, State Zip: Sanford, FL 32771
Phone: 407 427-0296
Resident of property? : yes
Contractor Information
Name Donald G. Geissler, Jr Sun State Siding, Inc Phone: 407 830-7778
Street: 510 Lake Lenelle Drive
City, State Zip: Chuluota, FL 32766
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Fag: 407 365-3194
State License No.: SCC048423
Architect/Engineer Information
Phone:
Fag:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Codeeog)
Revised: June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
llglaol 14-4
Signdbire of O er/Agent t Date_ 1 Signature of Contractor/Agent Date
Clv b.'V_hn
Cnt Owh r/Agent's Nime_'_ +
2.0/
i ature of Notary -State of Florida Date
KAREN M.
MY COMMISSION # FF 192427
EXPIRES: May 23, 2019
Owne
swed Notary Pu '
49 °rsps o Me or
Produce ID t Type of ID
bj;^ b y 3'?.5-'O 5 (o %-v
17. ora.1 d G . G et5 s(cr, J r•
Print Con ctor/Agent's Name
Me
Si re of Notary -State of Florida Dateatu
KE
MY COMMESSION iFF 192427
EXPIRES: a 23, 20t
Con erg , Npt rK wn to Me or
Prod
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps.
Fire Sprinkler Permit: Yes No # of Heads
APPROVALS: ZONING: ?_ -tAC rk UTILITIES:
ENGINEERING:
Flood Zone:
of Stories:
Plumbing - # of Fixtures
Fire Alarm Permit: Yes No
WASTE WATER:
BUILDING: n • I G
COMMENTS: 0 t n:_tr I I fie"' ear__ /f q 0A (2-4., e
un O VO (p l
Revised: June 30, 2015 Penn it Application
i l n n —,1' r11
SCPA Parcel View: 25-19-30-520-0100-1211 http://www.scpafl.org/ParcelDetaillnfo.aspx?PID=25193052001001211
CSDrivid John3on, CRA
PROPERTY
APPRAISER
WINOLE COUNTY, FLORIDA
Property Record Card
Parcel: 25-19-30-520-0100-1211
Owner: DENNIS FREDERICK S & JUDY
Property Address: 225 W SEMINOLE #211 BLVD SANFORD, FL 32771
I Parcel: 25-19-30-520-0100-1211 1
Property Address: 225 W SEMINOLE #211 BLVD
Owner: DENNIS FREDERICK S & JUDY
Mailing: 225 W SEMINOLE BLVD #211
SANFORD, FL 32771
Subdivision Name: GATEWAY AT RIVERWALK A CONDOMINIUM
THIRD AMENDMENT
Tax District: S3-SANFORD-WATERFRONT REDVDST
Exemptions: 00 -HOMESTEAD (2016)
DOR Use Code: 04 -CONDOMINIUM
ycy
210
N
r
1
V--r---
9
Value Summary
2016 Working 2015 Certified
BLDG 1 UNIT 1211
Values Values
Valuation Method Cost/Market Cost(Market
Number of Buildings 1 1
Depreciated Bidg Value 151,560 $151,560
Depreciated EXFT Value
Land Value (Market)
t--- -- —
Land Vane Ag
Just/Market Value
Taxing Authority
151,560 $151,560
Exempt Values
Portabity Adj
County General Fund 151,560
Save Our Homes Adj 0 I $0
Schools
Amendment 1 Adj 0
151,560
Assessed Value 1 151,560 I $151,560
Tax Amount wthout SOH: $3,084.,e
2015 Tax BE Amount $3,084.1
151,560
Tax Estimator
Save Our Homes Savings: $0.(
Does NOT INCLUDE Non Ad Valorem Assessments
Legal Description
BLDG 1 UNIT 1211
GATEWAY AT RIVERWALK A CONDOMINIUM THIRD AMENDMENT
ORB 6922 PG 141
Taxes
Taxing Authority Assessment Value Exempt Values Taxable Vane
County General Fund 151,560 i $50,000 101,56
Schools 151,560 j $25,000 - $126,56
City Sanford 151,560 50,000 101,56
SJWM(Saint Johns Water Management) 151,560 50,000 101,56
County Bonds 151,560 ; 50,000 101,56
Sales
Description Date Book Page Amount Qualified Vac/Imp
WARRANTY DEED 12/1/2015 1 08606 0527 203,900 Yes Improved
WARRANTY DEED 3/1/2009 07158 1091 18,821,500 No Improved -
Find Comparable Sales wthin this Subdivision
Land
1 of 2 1/12/2016 12:04 PM I
SUN STATE SIDING, INC.
510 LAKE LENELLE DRIVE
CHULUOTA, FL 32766
407 830-7778 phone
407 365-3194 fax
Submitted to:
Judy Dennis
225 Seminole Blvd West, Unit # 211
Sanford, FL 32771
PROPOSAL
State License SCC048423
PROPOSAL# 1
DATE 12/30/15
Job Location:
SAME
We propose to furnish all the materials and perform all the labor necessary for the completion of.
Furnish and install screen enclosure at entry lanai $1025.00
including custom screen door (3' x 6' 8") with "Tasman" locking handle,
Q1500 style door manufactured by PCA Products, Inc.
Site specific engineering plans & City of Sanford permit $ 300.00
COLOR: BRONZE
All material is guaranteed to be as specified and the above work to be performed in accordance with the drawings
and specifications submitted for the above work and completed in a substantial workmanlike manner for the
sum of: $1,325.00
With payments to be made as follows: FULL PAYMENT UPON COMPLETION (we accept CASH or CHECK only)
Any alteration or deviation from the above specifications involving extra cost will be executed only upon written orders
and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays
beyond our control. Owner to carry fire, tornado, and other necessary insurance upon the above work.
Workman's Compensation and Public Liability insurance on above work to be taken out by Sun State Siding, Inc.
THERE WILL BE A $50.00 BOOKKEEPING CHARGE IF THE INVOICE IS NOT PAID IN 30 DAYS.
Submitted by
This proposal may be withdrawn by us if not accepted within
DONALD G. GEISSLER, JR., PRESIDENT
30 days.
ACCEPTANCE OF PROPOSAL
The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to perform the work
specified. Payment will be made as outlined above.
r -
ism 3
Piinted-Name u,c ti Y) V\ S
2"/7-4t
I r VT. I, I T 11 1 I 11 11 9 A 1
t
Plan Types:
Screen Room
Pool Screen/Cage
Car Port
Patio Cover
Other:
RECORD COPY
JAN 2 8 2016
DALUMINU
A.ivMlnium & Cqnst(ucilfon E.nDino ri g
REVIEWED FOR CODE COMPLIANCE
PLbNS EXAMINER
DATE
SCREEN FILL-IN
Reference. GATEWAY 211 Newly I Revision
Project Address: 225 W. Seminole Blvd, Unit #211
City: Sanford, FL 32771
Contractor Name: SUN STATE SIDING, INC
Address: 510 LAKE LENELLE DRIVE
City: CHULUOTA, FL
Zip Code: 32766
Date: 1/4/2016
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING A CORRECTION OF ERRORS IN PLANS,
CONSTRUCTION OR VIOLATIONS OF THIS CODE
Phone/Fax: 407 830-7778 office, 407 461-9926 cell/407 365-3194 fax
Email: sunstatesiding@aol.com
Choose One: Mail Pick Up Fed Ex* 2 No of Copies
For FedEx option go to iv«,%v. aluminumscreendesign. com and provide FedEx account #)
Payment:, Check Credit Card"[?
For Credit Card option go to iwAv. ahuninumscreendesign. coin. to pay by credit card)
Engineering prepared by: e w/No
USANFORDLi
LjLjz%s 16- .
Engineer: Michael Thompson, MSc, P.E. (P. E, #47509) 3 6 3
5200 Vineland Road- Suite 250 Orlando, FL 32811
Off 407-529-3300 Cell 407-721-2292
Project Manager: Paul Thomas 386-479-9504 Fax 888-923-8181
Emait aluminumscreendesign@yahoo.t cm
Website: www.aluminumscreendesign.com CA#30930
NIP 1uryow7'A 17W.WkIIMNIiwlmlY
9
SCREEN-VESIGNDAIUM11101n & Constrodtion ngineorjngLJZA
Ultimate Wind Speed (mph): 130 Exposed Category:? C Risk Category;
Screen Room
Insulated Pan Roof
Fascia. Wall: Block Conventional
Uprights X Top Plate X Kick Plate
Pool Scree!!/Cage:
Dome Gable Mansard
Gutter Wall: Block Conventional
Beams X Uprights X Purlin X
Car Port:
Insulated Pan[--]
Fascia Wall: Block Conventional
Beams X Post X
Patio Cover:
Insulated Pani
Fascia Wall: Block Conventional
0
Beams X Post X
C oncrete:
Existing New: 4" Slab Pier Ribbon Footer X Pavers
Other:
screen wall fill-in with one door
Note: In the event that there is a conflict with the design plans and the general notes and design standard, the contractor shall utilize
the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and
the general notes and design standard.
11 MSR
VIEl AUMINUM SCREEN VESIONOASD'Alus"n'UMPtxi sz,a,.€,Y4 t1 9ssrPnQ
General Notes & Design Standards
Screen Patio Room Enclosure)
The following are general design standards. More stringent design standards may be noted on the plans. In the event
of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more
stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction.
Design Codes:
Florida Building Code 2014 (51 Edition)
Aluminum Design Manual 2010
ASCE 7-10
Design Loads:
Pursuant to FBC Chapters 16 & 20
Ultimate Wind: -130 MPH (FBC Table 2002.4) (35 ps, )
Risk Category: -See attach site specific plan sheet (FBC Table 1604.5)
Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3)
Additional Load requirements:
Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using
the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically
downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind
pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any
member, not occurring simultaneously with wind load.
Design Basis:
Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor
General Requirements:
Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of
information shown as correct and obligates himself to any expense, real or implied, arising from their use.
A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the
contractor and must be submitted to the engineer for approval.
The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify
all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or
structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans
prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the
review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall
bear no responsibility or liability for the construction of premises and accuracy of the drawings.
Foundation and Earthwork:
Applicable only when unsuitable soils are encountered.
When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer.
Soil bearing capacity — 2,000 psf Minimum
Provide neat excavation for footing and place concrete immediately after excavation and inspection.
Pump water from footing excavation if greater than one inch.
Compact all fill to 95% ASTM D698 density.
Unit soil weight = 105 pcf
Internal angle of friction = 30 degrees
Coeff. Of friction between footing and soil = 0.5
5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310
www.aluminumscreendesign.com
oASDy
L ,Yil .ii,i l' .3L '&-Ril3t . i i3ChX1 i i iQ9w7 f3
Structural Aluminum:
Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum
design.
All aluminum shall be 6005-T5 (E=10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046"
Splicing prohibited without prior approval as to location and type.
Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced.
Aluminum Protection:
Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or
other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as
heavy -bodied bituminous paint or water -white methacrylate lacquer.
Screws:
Aluminum self -tapping screws shall conform to ASME B18.6.4 specification.
Self—tapping screws shall meet the requirements of ADM J.5
Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches.
For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap
and end lap fasteners shall be no more than 2" from the end of overlapping sheets.
Bolts:
Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro -galvanized steel. Double cadmium
plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall
be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter.
Bolts shall meet the requirements of ADM J.3
Chair Rails, Purlins & Wind Brace:
Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's
specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent
dimensions and member sizes prior to ordering materials, fabrication and/or construction.
Wind Speed =130 MPH
2 x 2 Chair Rail = 6'-0" 2 x 2 Purlins = 6'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 9'-0"
2 x 3 Chair Rail = 8'-0" 2 x 3 Purlins = 8'-0" 2 x 3 Wind Brace = 8'-0" 2 x 4 Wind Brace = 9'-0"
Concrete
Conform to ACI 318, latest edition and ACI 301
Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi
Exposed chamfer edges shall be %"
Reinforcing Steel:
Conform to ACI 318 and 315, Latest edition
All reinforcement steel shall be ASTM A615 Grade 60.
Smooth dowels & ties shall be ASTM Al 85
Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet).
Deformed bar anchors shall be ASTM A496, Grade 70
Cover: Footing 3"
Washer:
Washers shall be used under bolt heads and under nuts.
Hole Alignment:
Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips
and foreign matter between contacting surfaces shall be removed before assembly.
5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310
www.aluminumscreendesign.com
00 AtUM1N0M$CREI5N=tG"
at.u t3 t s.m -3C lz r;tr a t$Yr €r•€trd c ng
Beams & Uprights:
In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more
stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations
prior to ordering materials, fabrication and/or construction.
130 MPH
PRIMARY BEAMS & COLUMNS -SCREEN & PATIO ROOM ENCLOSURES ROOF PANELS
Max Beam
Span & Max
Column Insulated Roof
Beam -Size Spacing Column -Size Max Column -Height Pan Roof Span Span
3" Spans 13'-
2 X 3 6'-0" 2 X 3 8'-0" 6" 3" Spans 15'-0"
6" Spans 20'-0" 2 X 4 8'-6" 2 X 4 8'-0"
2 X 5 10'-0" 2 X 5 9'-0"
Knee Bracing:
Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and
length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more
than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30'
max; 2 x 4 for beam span greater than 30'.
Purlin:
Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall
not exceed 7'-2".
Intermediate/Header Beam:
Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at
10 feet (max) when insulated roof span exceeds 15 feet.
Patio Cover:
Contractor is required to install insulated roof covering pursuant to the Florida product approval specification.
Overhang shall be a maximum of 1'-0" along the side, 3'-0" along the front and 1/2" along the front interface
between the super gutter and the attached pool cage knee riser wall.
Edge Distance:
Contractor is required to install uprights to provide a 3" minimum clearance from edge of slab and/or footer.
5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310
www.aluminumscreendesign.com
I I FT ATIL-iI I'I 1111I 1
Ifs'
4"`ROF1i 6L\%, tl x 5"T . ( Sf8 !
t c.r.0
z)(4
iizFii
3i'' ) z"..
Ib
ria(TiL£7 Pffi'iiu
piH Vo I(-
SC,eftJ W t.t.
jai - !
1-1 tc .. •
In the eWd of a con%d in meMber sees shorn on
wAt iC sfly fm P1m sod"general notes, the contractor must
utilize the more etrinvml momber size naq Iwe*.
I Z14`1
axZ jXZ
7J% 4z - k
ZXZ SUN STATE_SIbING: INC'
y
510 LAKE LENELLE DRIVE,
J tz
flDf?aG
CHULOOTA, FL, 32766
DONALD G. GEISSLER, JR.
SOC648423
407 830-7778 PHONE1407 365-3194 FAX
ALUMINUM SCREEN DESIGN
2 HINGE
2X2 POST .046 OR GRF,ATER
HINGE LOCATIONS
SCREEN DOOR FULL Z OR
DOOR JAM STANDARD DETAIL
EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24"
FILL IN DETAIL
BOTTOM PLATE IS ATTACHED TO
OCONCRETE WITH 2-1/4" X 1/4" TAPCON
5" X 2-1/4" IF THRU PAVERS)
6" FROM ENDS 24" O.C.
OALUMINUM FRAME IS ATTACHED
TO BLOCK WITH 2-1/4" X 1/4"
10 2" IF TO WOOD STRUCTURE)
6" FROM ENDS 24" O.C.
CHAIR RAIL & UPRIGHTS ARE ATTACHED
WITH EITHER:
BLIND SCREWED WITH (3) #10 3",
CAPRI CLIPPED WITH (4) #10 1" PER CLIP
BLIND CLIPPED WITH (4) #10 1" PER CLIP
KICK PLATE IS ATTACHED TO STRUCTURE
WITH #10 1" 6" FROM ENDS 18" O.C.
ALUME\ UMSCREENDESIUN.COM DESIGN STATEMENT MICHAEL THOMPSON
AL SCREENDESIG'N METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 5200 VENTELAND RD.
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" EMBEDMENT DEPTH
SUITE025@i
TAHOO • COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) ORLANDO
UI ' E 25
811PHONE #: 386-320-0256 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND
SPEEDS OF 130 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 101.4 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. i # 47509
FAX #: 888-923-8181 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS 30930
GATEWA.Y.A:T R1'VERWALK. PHASE 1
KURBIA COAMOMIMUM
C
HEE?' 21 OF 74 FIRST AAMNMIWENT ' d
LOCATED IN SECTION 25, TOWNSHIP Z 9 SOUTH, r
RANGE 30 EAST
iT I1I'r# 2 C17YOF SANFORD, SEMINOLE COUN Y, FLORIDA -
MODEL 8
73 UNIT "1212"- 1 I
v `
65.0' '3
C
28.3' 14.8'
9.5'j
t
7.5'
n s a -
10.0'
w o 8.6' 5.1' .3
1
4. S CD
o
K'
d 14.3
23.8' tri 1' N
UA c
N oCV E
v
5So
jJ16.2' 16.2' TV 1' 8.6 6.0 12.0 11
I
GRAPHIC SCALE
10 0 5 10 20
IN FEET )
1 inch = 10 f
UNIT "1210"
UNIT PLAN "F6"
Square Footage Total: 1,993 sf
FRONT{
RIGHT I LEFT
I REAR
v --
z
W
W
J
w
z
O
O
0
W
H
NOTICE.
THIS DRAWING 1S AN AS -BUILT OF THE CONSTRUCTED UNIT BASED UPON
DRAWINGS PREPARED BY CLFHACI & PETERSON ARCHITECTS FOR
PROJECT 1202244.1.
DIMENSIONS SHOWN HEREON ARE IN DECIMAL FEET
PLEASE NOTE. -
SQUARE FOOTAGE TOTALS ARE BASED THE UPON PRE-CONMUC71ON
ARCHRECHTUAL. PLANS OVERALL UNTr DIMENSIONS.
REQUIRED INSPECTION SEQUENCE , .
BP# 1I,- S6-; Address: ?_Z'5 LJ,, S'_N4.1&to*
BUILDING !PERMIT
Min Max Inspection Description
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Prepour
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Final Door
Final Window
Final Screen Room
Final Pool Screen Enclosure
Mobile Home Building Final
Pre -Demo
Final Demo
Final Single Family Residence
Final Building (Other)
REVISED: June 2014
E+ I.ECTRICa\L P1ERMIT ,
Min Max Inspection Description
Electric Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
ftwawc
Min Max Inspection Descriptiontion
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
IMECHAN.ICkl, WLERMI T
Min Max Inspection Description
Mechanical Rough
Mechanical Final
Min lOgax Inspection Description
Gas Underground
Gas Rough
Gas Final