Loading...
HomeMy WebLinkAbout225 W Seminole Blvd (3)Biwa FEB 1 1 2016 D v; CITY OF $ANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: / 10— JD Documented Construction Value: $ 1625.00 Job Address: 225 W. Seminole Blvd. Unit #601 Historic District: Yes No 0 Parcel ED: 25-19-30-520-0100-1601 Residential 0 Commercial Type of Work: New 0 Addition Alteration Repair Demo Change of Use Move Description of Work: screen enclosure at entry lanai with one door Plan Review Contact Person: Donald Geissler Title: President Phone: 407 461-9926 Fax: 407 365-3194 Email: sunstatesiding@aol.com Property Owner Information Name Jeffrey & Debra Condello Phone: 407 921-7317 Street: 225 W. Seminole Blvd. Unit 601 Resident of property? : City, State Zip: Sanford, FL 32771 Contractor Information Name Donald G. Geissler, Jr Sun State Siding, Inc Street: 510 Lake Lenelle Drive City, State Zip: Chuluota, FL 32766 Name: Aluminum Screen Design Street: 5200 Vineland Road, #250 City, St, Zip: Orlando, FL 32811 Bonding Company: Address Phone: 407 830-7778 Fax: 407 365-3194 State License No.: SCC048423 Architect/Engineer Information Phone: 407 529-3300 Fax: 888 923-8181 E-mail: aluminumsereendesign@yahoo.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDIN YOUR NOTICE OF COMMENCEMENT. I 58,06 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application "and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE:.In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract. is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the -executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. co d? d r• N ",ti : R s' Natiry - i of ftridri My Comm 102: Apr 24, 2011 Commission 0 EE 232 Signature of Conhwtor/Agent Q Date Donald G. Geissler, Jr Print Contractor/Agent's Name rG Date Signature of Notary -State of Florida ate OR_ -. Me or Produced ID Type of M v rZs 1 • ee d -f + BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Mn. Occupancy Load: # of Stories: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: 2-1 14 -'1" 4 -UTILITIES: ENGINEERING: FIRE: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: ' COMMENTS: C),- An :Sc Cee n 04 Fenni e-," c -s Slb. WI `C3q- Revised: June 30, 2015 Permit Applieation CAM A. MY COMMISSION 1FF EXPIRES: August 10, 2019 r''' Fa c' e Bottled Thtu budget Mr4ty Serrtes Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Mn. Occupancy Load: # of Stories: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: 2-1 14 -'1" 4 -UTILITIES: ENGINEERING: FIRE: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: ' COMMENTS: C),- An :Sc Cee n 04 Fenni e-," c -s Slb. WI `C3q- Revised: June 30, 2015 Permit Applieation REQUI[RED INSPECTION SEQUENCE Min Max Inspection Description Footer / Setback emwall Foundation / Form Board Survey Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof RoofDry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final.Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo Final Single Family Residence Final Building (Other) REVISED: June 2014 Addrecc! 7-'I< / 7 Co... - _ L. Minn Max ff-us, ection IlDescrm tnonn Electric Underground Footer / Slab Steel Bond Electric Rough T.U:G. Pre -Power Final Electric Final min Max 1<ns, ectionn llDescr .tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final ME C, I—CA%IF9 WM, T, i Min Max Itis, ection IlDescen tions Mechanical Rough Mechanical Final N9tinn Max 1[nn , eetioam Besc - 1tnom Gas Underground Gas Rough Gas Final RECORD COPY nf) ALUMINUM Aluminum & Construction Engineering Plan Types: Screen Room Pool Screen/Cage Pool Screen/Cage Car Port Patio Cover Other: SCREEN DESIGN Removable Screen - Remove screen when wind speed exceeds 75 MPH) Non -Removable Screen — Designed to withstand actual Wind Speed) SCREEN FILL-IN REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER DATE Reference: Gateway 601 New Revision Date: 1/25/16 Project Address: 225 W. Seminole Blvd. Unit 601 City: Sanford, FL 32771 Contractor Name: Sun State Siding, Inc Address: 510 Lake Lenelle Drive City: Chuluota, FL Zip Code: 32766 OBEA LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER ORSET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES. NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Phone/Fax: 407 830-7778 ofc/407 461-9926 cell/407 365-3194 fax Email: sunstatesiding@aol.com Choose One: Mail? Pick Up Fed Ex* 2 No of Copies For FedEx option got to www.aluminumscreendesiqn.com and provide FedEx account #) Payment:: Check Credit Card * For Credit Card option go to www.aluminumscreendesign.com to pay by credit card) Engineering prepared by: ILoiNc SANFORD O OA RTM Engineer: Michael Thompson, MSc, P.E. (P.E. #47509) . t O5200VinelandRoad —Suite 250, Orlando, FL 32811 . e1 J 6 _ Office: 407-529-3300 Cell: 407-721-2292 Project Manager: Paul Thomas 386-479-9504 Fax: 888-923-8181 Email: aluminumscreendesign@yahoo.com Website: www.aluminumscreendesign.com CA#30930 i ALUMINUM SCREEN. DESIGN Aluminum & Construction Engineering Ultimate Wind Speed (mph):` 130 Exposed._Category_: C ,Risk Category, Screen Room: Insulated Pan Roof Fascia Wall: Block Conventional Uprights x Top Plate x Kick Plate Pool ,Screen/Cage: Dome Gable Gutter Wall: Block Beams x Uprights Car Port: Insulated Fascia Beams Pan Wall: Block Mansard Conventional x Purlin x Conventional x Post x Patio Cover: Insulated Fascia Beams x Pan Wall: Block Post Conventional x Concrete: Existing x New: 4" Slab Pier Ribbon Footer x Pavers[] Other: Screen fill-in at entry lanai on existing concrete Note: In the event that there is a conflict with the design plans and general notes and design standard, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and the general notes and design standard. O DALUMINUM SCREEN DESIGN Alurihnum 5 ca:430:utiiC11 kngirarro;ing 4IE General Notes & Design Standards Screen Patio Room Enclosure) - The following are general design standards. More stringent design standards may be noted on the'plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2014 (5s' Edition) Aluminum Design Manual 2010 ASCE 7-10 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -130 MPH (FBC Table 2002.4) (35 psi Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements: Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310 www.aluminumscreendesign.com ALUJ4 tt UM SCREEN DESIGN omAsthlunkutnt E cat&zirueiicn Enpalt-zring Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum design. All aluminum shall be 6005-T5 (E=10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B18.6.4 specification. Self—tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro -galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Chair Rails, Purlins & Wind Brace: Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction. Wind Speed =130 MPH 2 x 2 Chair Rail = 6'-0" 2 x 2 Purlins = 6'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 9'-0" 2 x 3 Chair Rail = 8'-0" 2 x 3 Purlins = 8'-0" 2 x 3 Wind Brace = 8'-0" 2 x 4 Wind Brace = 9'-0" Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be 3/4" Reinforcing Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A185 Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Hole Alienment: Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips and foreign matter between contacting surfaces shall be removed before assembly. 5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310 www.aluminumscreendesign.com ALUMINUM SCREEN DESJGN 1E110SAS DAlu'-.11-tum E am:[r scicen i ngeC.trtirin ( Beams & Uarights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 130 MPH PRIMARY BEAMS & COLUMNS -SCREEN & PATIO ROOM ENCLOSURES ROOF PANELS Max Beam Span & Max Column Insulated Roof Beam -Size Spacing Column -Size Max Column -Height Pan Roof Span Span 3" Spans 13'- 2 X 3 6'-0" 2 X 3 8'-0" 6" 3" Spans 15'-0" 6" Spans 20'-0" 2 X 4 8'-6" 2 X 4 8'-0" 2 X 5 10'-0" 2 X 5 9'-0" Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater than 30'. Purlin• Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall not exceed 7'-2". Intermediate/Header Beam: Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds 15 feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of F-0" along the side, 3'-0" along the front and 1/2" along the front interface between the super gutter and the attached pool cage knee riser wall. Edge Distance: Contractor is required to install uprights to provide a 3" minimum clearance from edge of slab and/or footer. 5200 Vineland Road., Suite 250, Orlando, FL 32811. (P) 407-529-3300 (F) 407-529-3310 www.aluminumscreendesign.com FI7 Eta. Z y Y9,ai, 11 xZ GA-r wAY a ?-tVLN. wme- < 04pvgu-o Z-cq L0 H8 3 E [ FS ovfe G M. u. TYQ jN+1- &eo1 715T*r4& 6RE-craw caL,c, Zx,l11imyZXq Sn8 FX1$'rN( KNEEWfiL SUOEN DCO?-, (W [ v rrl UARt E5 rc.A. AWM FRflM£ t1oDxL #Q Isco SGKfit >•t wf Lt_ ,nss,G Kuk+ i o' ( !i' i b3•t `' -[- by.r " ' 63• r 63•s , E--- Conr'lort w+t wflY ' • SIDE I7 RtL Nbr TO 5. ,ALE !1 5- 19 7- + '_J xZ SUN STATE SIDING, INC. 510 LAKE LENELLE DRIVE I i l Z CHULUOTA, FL 32766 i 2 Z [ Qp4L£ DONALD G. GEISSLER, JR. SXi16 SCC048423 ZX `{ SM.6 • 407 830-7778 PHONE/407 365-3194 FAX i Zx Z In the event of a contlir in member sites shown onMfENA[ t e A tfie pians and the general notes, the contractor must utilize the more stringent member size requirements. ALUMINUM SCREEN DESIGN 2X2 POST .046 OR GREATER HINGE LOCATIONS SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL 0" to 36" 2 HINGE DOO EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O.C. FILL IN DETAIL BOTTOM PLATE IS ATTACHED TO OCONCRETE WTI'H2-1/4" X 1/4" TAPCON 5" X 2-1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. ALUMINUM FRAME IS ATTACHED TO BLOCK WITH 2-1/4" X 1/4" 10 2" IF TO WOOD STRUCTURE) 6" FROM ENDS 24" O.C. CHAIR RAIL & UPRIGHTS ARE ATTACHED WITH EITHER: O BLIND SCREWED WITH (3) #10 3", CAPRI CLIPPED WITH (4) #10 1" PER CLIP BLIND CLIPPED WITH (4) #10 1" PER CLIP KICK PLATE IS ATTACHED TO STRUCTURE D WITH #10 1" 6" FROM ENDS 18" O.C. ALUNffNUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON METAL IS.046 OR GREATER, ALLY IS 6005-T5ALSCREENDESIGNALLTAPCOSSHALLPROVIDESMINIMUMOF111/8" EMBEDMENT DEPTH 5200 VINELAND RD. SUITE 250 @Q YAHOO • COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) ORLANDO FL 32811 PHONE #: 386-320-0256 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 130 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 101.4 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. #47509 FAX # : 888-923-8181 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS 3 093 0, s GATEWAY AT IM ER WALK: PHASE 1C' •• A CONDOAMWE M ,C, FIRST AAMND1VIEIVT G.tJ (,V c .5-lll ti L-;k 5LOCATEDXNSECTION25, TOWNS M Y9 SOUTf3< 2.0' nyRANGE30EAST CITY OFSANFORD, SEMIN'OXX COUNTY, FLORIDA err WB' 88 OF 7 UNIT' 1801 MODEL GI Penthouse "G1" Square Footage Total: 3,399 sf NOTICE: 7HIS DR4MNG IS AN AS—BUILT OF 711E CONSTRUCTED UNIT SkiED UPON DRAWINGS PREPARED BY CUHAC) PETERSON ARCHITECTS FOR PROJECT 1202244.1. DIMENSIONS SHOWN HEREON ARE IN DECIMAL FEET PLEASE NOTE;- SQUARE OTE; SQUARE FOOTAGE TOTALS ARE RASED THE UPON PRE—CONSMUC77ON ARCHRECHTUAL PLANS OVERALL UNIT- DIMENSIONS. GRAPHIC SCALE 10 0 5 10 2D IN FEET ) 1 inch = 10 ft. Engiacm Planner$ LaredsrapeArdrltects Susccyors CmtsEsuclion Martogemar# mww-ephengineer8.c0m 50 0 Wert Fatten Shut Sm frr4 FL MJ -A P.O, B= 28K Sag W4 Ft 327724303 FLaie 007S22MJ F, = 407-MG09 LAxnwd Bus*= RerWraHOn Numb 7243 iG- % D PLANS I ENG. DEPT. - LIMITED COMMON ELEMENT SUN STATE SiDING, INC. 510 LAKE LENELLE DRIVE CHULUOTA, FL 32766 407 830-7778 phone 407 365-3194 fax Submitted to: Debbie Condello 225 Seminole Blvd West, Unit # 601 Sanford, FL 32771 PROPOSAL State License SCC048423 PROPOSAL# 1 DATE 1/15/16 Job Location: SAME We propose to fumish all the materials and perform all the labor necessary for the completion of: Furnish and install screen enclosure at entry lanai $1,625.00 Including custom screen door (3' x 6' 8") with "Tasman" locking handle, Q1500 style door manufactured by PCA Products, Inc. Rescreen both balconies. Including cleaning the metal, re -caulking and $ 500.00 refastening where required. Remove 3 sections of callings and reinstall with new fasteners where required. Site specific engineering plans & City of Sanford permit $ 275.00 COLOR: BRONZE All material is guaranteed to be as specified and the above work to be performed in accordance with the drawings and specifications submitted for the above work and completed in a substantial workmanlike manner for the sum of: SEE ABOVE With payments to be made as follows: FULL PAYMENT UPON COMPLETION (we accept CASH or CHECK only) Any alteration or deviation from the above specifications involving extra cost will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon strikes. accidents or delays beyond our control. Owner to carry fire, tornado, and other necessary insurance upon the above work. Workman's Compensation and Public Liability insurance on above work to be taken out by Sun State Siding, Inc. THERE WiLL BE A $50.00 BOOKKEEPING CHARGE IF THE INVOICE IS NOT PAID IN 30 DAYS. Submitted by DONALD G. GEiSSLER, JR., PRESIDENT This proposal maybe withdrawn by us if not accepted within 30 days. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to perform the work specified. Payment will be made as outlined above. PrintedName f"J`GCQ 4OI /lO