Loading...
HomeMy WebLinkAbout1809 Palm WayCITY OF SANFORD BUILDING & FIRE PREVENTIOND PERMIT APPLICATION M 1 0 2016 Application No: V] _7 l3Y : Documented Construction Value: $ 3 q/,/ 0 76 Job Address: O9 N m J tne:: 1 71 Historic District: Yes No Parcel ID: 3- \-- ,3-OopO - Op S O Residential [r Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work:" COh v er' T 6 6'd-12 f) 6- e Plan Review Contact Person: Phone: 150q- jo 7J --?17 Fax: Title: Email.: J6rAI 2 SA/JC ,P 7 ate Qa 77. nJP j- Property Owner Information Name <401 I rne— ',::3X-r\Ct le 7, Phone: (5-by) (07G(o . Street: 1 g0 9 PoAyn wcw Resident of property? : `f City, State Zip: SQ nd ` 3 ot11 r it"s B' r Contractor Information Name Street City, State Zip: Name: - Street: City, St, Zip: Bonding Company: Address: Phone: Fax: State License No.: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51' Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, &m— may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. r -'- to Signature of Owner/Agent Date 1a 6 rim el 15a,-YIC. I e -7, Print O /Agt'sNam - -- — LD-I c, Signature o N a -St e o FI rd Date a;Fr ANNETTE SCOTT Notary Mlhllc - State o1 Florida My Cc r0res Jan 16, 2018 Co" rF 071766 Bondec ' 'Plary Assn. Owner/ ally Known t or Produced ID Type of ID F -- ip Permits Required: Construction Type: Total Sq Ft of Bldg: 14 Signature o Contractor/Agent Date NA, Print Conti ctor/Agent's Name h Signature o otary-State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Building Electrical Mechanical Plumbing Gas[:] Roof Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Flood Zone: of Stories: Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: 46 1 O 1, UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: ZI - COMMENTS: Ok TO Ov'der Ivo- I ( - 03 . Revised: June 30, 2015 Permit Application OWNER BUILDER STATEMENT/AFFIDAVIT Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Florida Statutes are quoted here in part for your information to indicate the authority for exemptions for homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities. OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT BY SIGNING THIS STATEMENT, I ATTEST THAT: (Initial to the left of each statement) I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. I understand that, as an owner -builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that a contractor is required by law to be licensed in Florida and to list his or her license numbers on all permit and contracts. I understand that I may build or improve a one -family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or p residence must be for my own use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within in 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates this exemption. I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. I understand that I may not hire an unlicensed individual person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I have the licenses by law and by city ordinance. employ required I understand that it is a frequent practice of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner - builder and am aware of the limits of my insurance coverage for injuries to workers on my property. I understand that I may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on my building who Is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers' compensation for the employee. I understand that my failure to follow these laws may subject me to serious financial risk. Rev. 9.14.2009 I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern owner -builders as well as employers. I also understand that the construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. I am of aware of construction practices and I have access to the Florida Building Codes. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, the Florida Department of Financial Services, and the Florida Department of Revenue. I also understand that I may contact the Florida Construction Industry Licensing Board at 1-850-487-1395 or at www.myflorida.com/dbpr/pro/cilb/ for more information about licensed contractors. I am aware of, and consent to, an owner -builder building permit applied for in my name and understand that I am the party legally and financially responsible for the proposed construction activity at the address listed below. I agree to notify the building department immediately of any additions, deletions, or changes to any of the information havethatI provided on this disclosure or in the permit application package. Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Construction Industry Licensing Board, the Department of Business and Professional Regulation and the building department may be unable to assist you with any financial loss fJ that you sustain as a result of a complaint. Your only remedy against an unlicensed contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is property licensed and the status of the contractor's workers' compensation coverage. Property Address: \ % Q)0 F cork e- 7, , do hereby state that I am qualified and capable of performing the requested construction involved with the permit application filed and agree to the conditions specified above. Signature of Owner -Builder Form of Identification Must be Photo ID) Date A violation of this exemption is a misdemeanor of the first degree punishable by a term of imprisonment not exceeding 1 year and a $1,000.00 fine in addition to any civil penalties. In addition, the local permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy for unlicensed activity against the owner and any person performing work that requires licensure under the permit issued. Rev. 9.14.2009 an Construction Materials Shopping list Electrical: 1 Gang blue plastic interiors Carlon 18cu. Plastic round ceiling elect. Box Carlon 135cu. In 2 gang plastic Raco 13cu. 1 gang metal handy wall electric box Steel City 15.8cu metal ceiling electrical Box Wire 12 (12x2) 250 ft. Cooper wiring devices 125volt. 15amp Raco 1ganng rectangle metal electrical box cover Cooper wiring devices 10 pieces 15 qmp GFI paq.3 125 volt. 15 amp. Stud. Support brackets Stud. Support brackets (small) paq.30 Recessed light housing 6" IC Pluming: Pipe 2 inch. X10 280 PSI PVC Pipe 3 inch. X10 280 PSI PVC Pipe 1 1/2 inch. X10 280 PSI PVC 3/4 CPVC hot/cold loft. 100PSI 1/2 CPVC hot/cold 10ft. 100PSI OATEY 4ft.oz. CPVC cement and primer CPVC 900 elbow paq. 20 unids 1/2" CPVC 90' elbow paq. 10 unids 3/4" CPVC coupling paq. 20 unids 1/2" CPVC coupling paq. 10 unids 3/4" CPVC Cap 1/2" paq 10 unids CPVC adapter paq. 10 unids CPVC straps 1/2" paq. 5 unids CPVC straps 3/4" paq. 5 unids PVC 2" Trap fitting Shower pan liner Shower pan liner cement PVC shower drain 3" toilet PVC flange sub -total: 303.64 sub -total: 356.93 Interior Walls: Drywall 1/2 white Drywall 1/2 green Tape Self-adhesive joint tape Screews 1 1/4" 25lbs. Joint Compouns 20min. Joint Compouns 5min. Texture bag 2x4x10 Pressure treates 2x4x8 Pressure treates 2x4x10 Framming wood 2x4x8 Framming wood Furrys P/T Prime 5 galon bucket Flat paint 5 galon bucket Gloss paint 1galon bucket Doors: 36"x80" Steel Prehung entry door Front door lock Interior doors 30" Interior door 32" Pocket door hardware kit (32" door) sub -total: 1,061.22 sub -total: 622.97 r Total: $ 2,344.76 N THIS INSTRUMENT PREPARED BY - Name: //1,1 Address• U 5" Yl NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: MARYANNE MORSE? SEMINOLE COUNTY CLERK OF CIRCUIT COURT & COMPTROLLER SK 8647 Pq 572 (1Pgs ) CLERK'S T 2016025338 RECORDED I13/],li /21.116 09.5'; . i:6 All RECORDING FEES $10.00 RECORDED BY hdevare Parcel ID Number: 3 , ,. >I. w3 - ccDo '- UCH jc, The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following infomiation is provided in this Notice of Commencement. DESCRIPTION OF PE TY: (Legald scr' do of the property and street address if available) GENERAL DESCRIPTION OF IMPROVEMENT: OWNER INFORMATION: Name: •T, il- t r,— Address: 13Ce\ 96Am wcUi S tn 'c I ,. :32-171 Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: Name: /A Address: Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: IV A-4 Address: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST 5 p. INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY ,-, jrS• ° BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. " y Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true.`•. to the Pest,of my kno edge and belief. aha rxcL Gi Z Q:vynQ— JC".•h&I rL •• Owners Signature V Owner's Printed Name w Florida Statute 713.13(1)(g): "The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead' c 0 w CStateof E I 'ICI County of _1 t 'd.)U' a 2 II,h ' iTheforegoinginstrumentwasacknowledgedbeforemethis day of _ ' C c 1 .20 G by Ct i G 1\ it .ke Z Who is personally known to me Name of person making statement OR who has produced identification type of identification produced: 1- L- D L nri ANNETTE SCOTT Notary. Publk - State of Florida My Come-'EXPIM Jan 1 6. 2018 Notary Signature` f°F Comlplasion / FF 071760 Banded itrag111rfonal Ngtay Aun. Co a e o: APPLICATION FOR IMPACT'FEE STATEMENT--..... E COUNTY - Check one box. ALTAMONTE SPRINGS LAKE MARY FrSANFORD CASSELBERRY (East of Hwy 17 & 92) LONGWOOD WINTER SPRINGS CASSELBERRY (West of Hwy 17 & 92) OVIEDO CENTRAL FL RESEARCH PK Site Street Address: %q,QPk QaSm 3a1_7k Tax parcel I.D.# : Legal Description Attached Subdivision Name: Lot: Block: Owner Name: czX m Z J 6%e_ti Mailing Address: wE64 If L - 3 a. -I -11 City: Is a_f\ State: F\ Zip: 3a-1-71 Phone: CSo4 Sk-Tf0 Fax. no.: — Contractor Name: 1.1 /A . Mailing Address: City: State: Zip: Phone: Fax. no.: Protect Name: Building Name: Proposed Residentail Use: (Check one) Single -Family Duplex Townhome/Condomin'ium Mobile' Home Apartment List the number of dwelling Units: Numbet'of Buildings: Proposed Nonresidential Use: List the use and size of Building: (Example: Restaurant, medical office, general office. If a mixed use, list all.) Use # 1 Size Use #3 Use #2 Size Use #4 Size Size Proposed Change of Use: (Applicant may be entitled to impact fee credits for prior uses.) This use replaces a use of: Size: _ Size: Yes No If within the City of Altamonte Springs, is a fire sprinkler system proposed? If yes, please submit construction drawings indicating the sprinkler system. NOTE; .: Please submit a site construction and 'building floor plan,, with the- application.: ,,lt will ,be retuinL-dto you once the assessment is cb)r plete: . OFFICE, ,USE ONLY Statement no. Date: Input by: Comments: LApd\pmjects\impact fa-MASTERS\City impact fee fomt.doc Revision City of Sanford Response to Comments APR 2 0 2016 i Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 BY: ( Email: building@sanfordfl.gov Permit # 16 7 7 Submittal Date z/ - o? O - D l6 Project Address: / S 0 f 19 IM w,4 -,o R 7 7 7 Contact: 1 q I'm e S/- /,-C %G Ph: ,T OJ" - 6 7 6 — $ 7 6 Fax: Email:J14 7- 3 6a ®qTr NeT' Trades encompassed in revision: BBuilding lumbing , 0 Electrical Mechanical Life Safety L9 Waste Water Department General description of revision: N<Tc.,J SPA D l- f /.-;z 0 S ROUTING INFORMATION Approvals Utilities Waste Water Planning Engineering Fire Prevention 11 Building -5r W.2741 CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION 300 N. PARK AVENUE SANFORD, FLORIDA 32772 PHONE: 407.688.5150 FAx: 407.688.5152 PLAN REVIEW COMMENTS Application Number: 16-774 Date: March 17, 2016 Contact Person: Contact Fax Number: Contact E-mail Address: JamieSanchez360(a),tt.net Project Description: Convert Garage to Living Space Job Address: 1809 Palm Way The following is a list of the areas of the submitted plans that contained violations of the codes adopted by the City of Sanford and enforced by the Building Division. The violations noted must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal. Changes to construction documents that require an Architect or Engineer's seal must be submitted with the appropriate seal. Provide two copies of affected plan sheets and/or supplemental information as requested. COMMENTS: 1. Please provide a structural wall detail for closing in the space where the existing garage doors are located. FBC 107 2. Please provide a structural wall detail for the new door that will be installed, including the requiredheader. FBC 107 3. The kitchen, as labeled on the plans, is required to be equipped with a cooking appliance. Please show a cooking appliance and electrical requirements for the appliance on the plans. FBC 107, FBC 1208 4. The A/C system is indicated as existing. Please provide a duct layout showing the existing ductwork to verify code compliance. If any new ductwork will be installed, please label as new on the duct layout. FBC 107 5. In accordance with the 2014 Florida Energy Conservation Code, the ceiling is required to be insulated to a minimum R-30. Please provide a note on the plans addressing the ceiling insulation. FBC 07 6. Please provide the size of the windows so egress requirements can be verified. FBC 107 7. Please provide a note on the electrical plan that arc -fault protection is required for receptacles in the bedroom and living area. FBC 107, NEC 210.12(A) 8. Please provide a note on the Electrical Plan stating all receptacles must be tamper -resistant. FBC 107, NEC 406.11 Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Please direct any questions you may have to Steve Fiorey at 407-688-5065 or by E-mail at steve.fiorey a,sanfordfl.gov . Respectfully, Steve Morey Residential Plans Examiner 2- REQUIRED INSPECTION SEQUENCE RP# BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey p Zp SIab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In L o Frame Insulation Rough In Firewall Screw Pattern p Drywall / Sheetrock Lath Inspection Final Solar Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo Final Single Family Residence Final Buildin (Other) Address: ELECTRICAL PERMIT •<: r - y ^n . .ti r min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final 17 y,{1 f_'#+', i _ 4..-r.a.Rr..M.M•-..4 Y..iei Min Max Inspection Description o Plumbing Underground Soto Plumbing Sewer Zc Plumbing Tub Set Plumbing Final MECHAN ICAL IPE RM IT J Min Max Inspection Description 10 Mechanical Rough Mechanical Final 0 Min Max Inspection Description Gas Underground Gas Rough Gas Final REVISED: June 2014 JEUMEN(a) Steel STEEL, STEEL EDGE DOOR 6'4" N18'-0" SINGLE OUTSIN MG OPAQUE IWACT DOOR 1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE FLORIDA CURRENT BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE' (WHZ) REQUIREMENTS. 2. WOOD BUCKS, BY OTHERS. MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE 3. PRODUCT ANCHORS SHALL BE AS LISTED AND SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WNJ_ DRESSING OR STUCCO. 4. IMPACT RESISTANT SHUTTERS NOT REQUIRED. 5. DESIGN PRESSURE RATING SHALL BE AS FOLLOWS: FOR 6'8' WOOD FRAMES - SEE TABLE SHEET 1 FOR 8'0' WOOD FRAMES - SEE TABLE SHEET 1 6. THIS SYSTEM WAS TESTED FOR 2.86 LBS. WATER PRESSURE AS PER ASTM-E331. 7. SEE DESIGN PRESSURE TABLE h NOTES BELOW REGARDING WATER INFILTRATION REQUIREMENTS. DOOR LEAF CONSTRUCTION: Face shoehe 24 ga. (0.020') minimum thickness, Galvanized Steel A-525 commercial quality - AKDO per ASTM 620 with minimum average yield strength Fy-26,240 psi. Core design: Expanded polystyrene with 1.0 to 1.25 lbs. density, by JELD-WEN. Panel Constructian: Steel face sheets glued to expanded polystyrene (EPS), with steel top and bottom role and steel stiles with a wood lack block reinforcement. The hinge stile contains a MDF board for added hinge support Frame Constructlon (Both Frame T)oes): The hood jambs and side jambs are mortised, butted and joined using (3) 7/8' x 2' wire staples. An bumper threshold OUTSWING threshod was unib7ized at the sill. An optional aluminum Alit threshold Is available. TABLE OF CONTENTS SKI" DESCRIPTION 1 TYPICAL ELEVATIONS do GENERA_ NOTES 2 VERTICAL CROSS SECTIONS h BOM 3 HORIZONTAL CROSS SECTIONS 4 ANCHORI I OK;A1 1UNZ, k DE ALS 5 UNIT COMPONENTS X-1 3/4' OA _ MAIL FRAME WIM 3' OA MAX PANEL WOM 3'-1 3/4' O.A. 3' OA 1NX. PANEL wIOTN d 27 e o r o b I 6'8" SINGLE OUTSIIING UNLT__(X) SCALE: 1/2" =1'—O" NOTE: USE OF ITEM 11 MEETS WATER INFILTRATION REOUIREIRENTS UP TO A DESIGN PRESSURE OF +70 PSF (UNLESS VALUES IN DESIGN PRESSURE TABLE TO RIGHT GOVERN) ocr) 0tb Z_ O J¢ M Q. WWGGo Zo3gaaVIED/ 0 M to q 6 Nc d M Y a Y SANFORD O AARTN z . 3 a f C1 n16 774000- t:J J 00 Z J U) 47 i ~ m O N GO W W Z Q m O U2 8'O" SINGLE OUTS)rING UNIT (X) ovmRANG SCALN.• 1/ 2" =1'—O" LENGTH I 1 I ' .. • I .. / •l./i1 iN:1,. • 1. a,41 r : I DESIGN PRESSURE RATING WHEK WATER KMLTRATIOR REpEE1Ea IS R®m WHERE UUM 4ELTRATMN FIEMMEMEW 6 NOT IEIDm 6'8- ( X) 70.Opsf 80.Opsf 80.Opsf 80.Opsf X) F8 61.Opsf 65.Opsf 61.Opsf 65.Opsf Dlgnally signed by Hermes F Noreo, PE. Reason: I am approving this document Date: 2015. 04.10 0909:59 -04'W Ld nann jhQ : PRODUCTHASNOTBEENRATEDFQRAiWATERINFILTRATION UNLESS USING REM 1 o o 0 fF IFAUTHORITYHAVINGJURISDICTIONREQUISTHATPRODUCT MEETS THIS REQUIREMENT, PRODUCT SHALL BE USED WHEN INSTALLED OVERHANG SUCH o !2 o 0o 2 a a o W m Q O AT LOCATION Q1 BY THAT 0 KAT10 = OH LENGTH + OH HEI T. O O Q O HERMESF. NORERO P.E. NO. 73778 DATL. 12 07 07 sic NOTED 7 FLORIDAONO. IMr: EAG aI By. SAFFE DRWNG NO-' DC9970 ONAt G% CAM newu`uoDOOMOH _ IRlIII1111\t r n MEM rt 900I SMEf 1 OF 5 00(o 3/4" EDGE 3/4" MIN. EDGE DIST. 2 1/2" MIN. w EMBED. 1 1/4" MIN. m 9 EMBED Y r 2! 31 •a • x N N 32 T ` 3 SEE DETAIL JA SEE DETAIL A ON SHEETON SHEET 5 18 13 z26z zz 33 N 16cn in J 55 00cn OD 00 OD 00 tD O CD OD \\ N N 'oW n n om mrn m rn I I N tl miD N tl OD o 000 XX I I I I (D m D a0 2 x x 2 La O U C9 Z Z W_ W_ W W a axx W W WW 00 4? 00 Y6 00 1 1/4" MIN. EMBED 2 1/2" MIN. EDGE DIST. A 9 2 HOOD PR KE INSTALLATION SCALE.- 3" =1--O" 2 CONCRETE INSTALLATION SCALE: 3" =1'-O" ISE 4 z .: .. m 2 1/2" MIN. 9 w EDGE DIST. Oi`S`S/ONAI E G%2`: 11nn11110 HERMES F. NORERO FLORIDA P.E. NO. 73778 uoo Dram W- a0 VW www WON ala m rlat n pm• o 0 Jm J Z 0Qc`? 2E W co ut Y jMYa 12107107. AS NOTED BY: EAG Br:S. SAFFE Mc No: DC9970 r 2 . 5_ 37 3/4" MAX. FRAME WIDTH 32 36' MAX PANEL WIDTH 31 22 4 21 25 26Q 5 20 23 16 26 20 16 SEE DETAIL A j 13 INTERIOR ON SHEET 5 1 27 2 1 /4" MAX. SHIM SPACEti1/2" MIN. EMB. 1 1/2" MIN. EMB. A Z SIN T P 3 HOOD INSTALLATION SCALE.• 3" =f'—O" v 2 1/2" MIN. SEE DETAIL A — INTERIOR v ' v EDGE DIST. d ON SHEET 5 2 1 1 1/4" MAX. SHIM SPACE-- 1 1/4" 1 1/4" MIN. EMBED. B g CONCRETE INSTALLATION SCALE: 2 1/2" MIN. EDGE DIST. EMB. 36- MAX. PANEL WIDTH ao ao a 013 00 00 0 a FA 00 OA o 9100m1® nn0 0 $ ONE a II F. 0 n 0 O1. J 0m a Cc Z o J (7 ZW OD W Y ao 3g¢ o^to MY0- HERMES F. NORERO DATG12 07 U/ FLORIDA P.E. NO. 73778 Saxe AS NOTED om up EAG ov. arS. SAFFE oRM" NO.: DC9970 uao oos 3 of 5 9 1! 9 1! 9 1 9 1 9 1 9 1 9 1 1 6' 6 6'n 00 DD N 6 E 8 9/16' 8 9/16' SEE DETAIL D 6. I 1 _ 7 9 Tom. I o in 7 9 \ W ANCHORING LOCATIONS 6 '8" OUTSIIING SINGLE UNIT (X) SCALE. 1/2" =1--0" SEE DETAIL A -L 6' 1 — 11-0 1/ 7 9 1/4" 4 5' 1'-0 1 /4" 1'-0 1/4 7 9 TP - 1'-0 1 /4 O1'-0 1/4' B SEE DETAIL B 1'-0 1/4" C C VTYP.— SEE m-reu n 8 6'--i i- i 6---1 r— ANCHORING LOCATIONS 8'0" OUTSIIING SINGLE UNIT (XJ SCALE: 112" ITA[i C nR7 A/1. n SCALE.- 3" =1'-0" SCALE.• 3" 3 SEE DETAIL C OD 0 J Q DETAIL A m z0¢C? Z UJ QD W Y = OD 3g¢to Ll11 M Y 0- Uz 3 Z 00La Ld O WZ OJQEn Lu J = W •oo Z co 0 e 1111 F. ' t0 nw In zO HERMES F. NORERO FLORIDA P.E. NO. 73778 oAh:72 07 07 7 _ -* _ scxt::AS NOTED orr— ar: FAG cmc er:S. SAFFE DRAWING NO.: p0ctcs ...... P tj:` DC9970 S/ONA%-E`N; ? aao oio s .c rn Rmon'n 9EEI 4 OF 5 1 3/4. 4— 2 3/16" -I 1FINVERMIEM PIER SCALE.- 6" =f'-O" 2 3 13 SCALE 6" =f'-O" 2 SCALE' 6" =f'-O" 4" N O O 1/16" (Min) SCALE. 6" =f'-O" 1 3/4- r —1 1 1 /4" 18 20 SCALE 6•• = -O" 4" 4— 2 1/2" I 1 10 SCALE. 6" =f'-0" 18 3/4' for 8'-0" DOOR 11 3/4" FOR 6'-8" DOOR 1/4" 3- /0 IA. VARIES WfTH HARDWARE USED 21 '2 SCALE• 8" =1'-0" r 1 3/4" r , 1 In n I 1 3/16" 19 SCALE• 6" =f'-0" O co 010 m O ZOQM a lL (V THRESHOLD 11 GoZYG SCALE. 6" =f'-0" g Lu r--R///%// UPPER THRESHOLD126" =f'-O" c SCALE.- 3 rn o=) 0o F 1 3/16' J Z T w z oa 1 JW 2 23 s" CoIN rc SCALE =1'-0" Co 3/16" C-SINK. — DPsTA/L ALE• A SCf/4" =f'-O" C' HERMES F. NORERO wh: 12107107 Z 0 FLORIDA P.E. N0. 73778 SrAE AS NOTED7 _ mm By. FAG v . T/lT = pOc'• NC ax. er:S. SAFFE DRAwMc NO.: WNAIEaG aw""wDWow C9970` sErr BY OTHERS EXTERIOR FINISH BY OTHERS PERIMETER CAULK BY OTHERS O.A. WINDOW HEIGHT EXTERIOR SEE GLAZING DETAIL 1 3 THREADS MIN. PENETRATION BEYOND STEEL STRUCTURE #8 SELF -TAPPING SCREW INSTALLATION ANCHOR MIN 20 GA. STEEL FRAMING BY OTHERS v4 SHIM SPACE 3/4' MIN. EDGE DISTANCE 8 SELF -TAPPING SCREW INSTALLATION ANCHOR MIN 20 GA. STEEL FRAMING BY OTHERS 3 THREADS MIN. PENETRATION BEYOND STEEL STRUCTURE SHEATHING—' 7/8' O A. INSULATED GLASS: BY OTHERS 1/8" ANNEALED 0.090' SOLUTIA PVB INTERLAYER 1/B' ANNEALED AIR SPACE EXTERIOR FINISH 1/8" ANNEALED BY OTHERS O INTERIOR PERIMETER CAULK WINDOW BY OTHERS WIDTH J VERTICAL SECTION / L HORIZONTAL SECTION 5 JAMB - STEEL STUD FRAME 1 1/4' MAX 3/4" MIN. SHIM SPACE EDGE DISTANCE PLY GEMWINDOWS 433 R MAIN ST . /0 WX 5" ROCKY MOLW. VA 2401 INTERIOR PR 540 "346 FX 540+44-6W M04 SEE GLAZING Y H c N 25 $ DETAIL 1 w ygth p j eL a Q < Of < w va V,m< w N w O O ZZ R10DA, LL w at < uio EXTERIOR y w O° 4o of a Q NN 5 HEAD - STEEL STUD FRAME I I 4312 FIN V) 4812 FIN 1/2' MIN. GLASS BrTE SEE GLAZING SHIM SPACE O H 2 LbZ DETAIL 1 GE MOMENTIVE 3/4' MIN. EDGE DISTANCE r p WQ 1 EXTERIOR OA WINDOW HEIGHT RTV5 18 SILICONE INTERIOR GLAZING DETAIL 1 PERIMETER CAULK BY OTHERS EXTERIOR FINISH BY OTHERS / SHEATHING BY BY OTHEERS) 1/4" MAX. 3/4' MIN. SHIM SPACE r EDGE DISTANCE MIN 20 GA. STEEL FRAMING BY OTHERS 3 THREADS MIN. # 8 SELF -TAPPING SCREW PENETRATION BEYOND INSTALLATION ANCHOR STEEL STRUCTURE I VERTICAL SECTION 5 SILL - STEEL STUD FRAME 12 FIN S O8SELF -TAPPING SCREW v INSTALLATION ANCHOR o 0N STEEL FRAMING s8Y;`THERS LL INTERIOR ETRATION ONDTESELSTRUCTURE0 as t* SHEATHING BY OTHERS EXTERIOR FINISH ty '• O, BY OTHERS SEE DATNG DETAPERIMETER CAULK N T m3! ... ui BYOTHERSEXTERIOR p A Q o 3 izz0 I'D Y S uN Z WINDOWDWG #: WIDTHHORIZONTAL SECTION PGW036 5 JAMB - STEEL STUD FRAME SHEET: 5 OF 5 4912FIN INSTALLATION NOTES. 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN, UNLESS OTHERWISE STATED 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF t1/2 INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (I E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. FLANGE INSTALLATION: FOR INSTALLATION THROUGH 1X BUCK TO CONCRETE)MASONRY, OR DIRECTLY INTO CONCRETE/ MASONRY, USE ONE (1) 3/16 INCH fTW TAPCON PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1 114 INCH MINIMUM EMBEDMENT. 5. FLANGE INSTALLATION: FOR INSTALLATION THROUGH STEEL STUD USE ONE (1) 010 SELF -TAPPING SCREWS PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND STEEL STRUCTURE. 4. FIN INSTALLATION: FOR INSTALLATION THROUGH STEEL STUD USE ONE (1) 98 SE -TANG SCREWS PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM 'ENETMTION BEYOND STEEL STRUCTURE. 7. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 8. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING DISSIMILAR MATERIALS MUST BE SEPARATED OR COATED. 9 FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 10. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESSTHAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 11. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A - CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. B. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90. C. STEEL -MINIMUM YIELD STRENGTH OF 33 KSI. MINIMUM 20 GA WALL THICKNESS. PLY GEM WINDOWS BUILDER SERIES 471214812 SINGLE -HUNG GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC) EXCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: AAMA/WDRWCSA 101/1SI/A440-05 ASTM E 188"2/05 ASTM E 199&AW05 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X AND METAL STUD FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND ZX BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE, BUCK DESIGN AND INSTALLATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED TO PROTECT THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE IN WIND ZONES 3 OR LESS. 6. WINDOW FRAME MATERIAL ALUMINUM 6W3-T3 7. GLASS MEETS THE REQUIREMENTS OF ASTM E13W GLASS CHARTS. SEE SHEET 5 FOR GLAZING DETAILS. DESIGNATIONS 'X'ANO '0" STAND FOR THE FOLLOWING: X: OPERABLE PANEL O: FIXED PANEL IMPACT) TAPE OF CONTENTS SHEET ION SHEET DESCRIPTION I GENERAL 6 D45TALLATION NOTES 2 rA ELEVATIONS ANCHOR LAYOUTS 3 4712FL VERTICAL 6 HORIZONTAL SECTIONS 4 4712E VERTICAL 8 HORIZONTAL SECTIONS 5 A 612F VERTICAL, HORIZONTAL SECTIONS 6 6LAZIN6 DETAIL OVERALL SIZE MISSILE IMPACT PRODUCT DP RAT" RATINGWIDTHHEIGHT LARGE AND SMALL 4712F IR 53' 72' 50 /- 57 PSF MISSILE RATED LARGE AND SMALL 4712FL IR 53' 72' 50 /- 57 PSF MISSILE RATED LARGE AND SMALL 4812F IR 53' 72' 50 /- 57 PSF MISSILE RATED LARGE AND SMALL 4712E IR 48' 84' 50 /- 57 PSF MISSILE RATED LARGE AND SMALL 4712FL IR 48' 84' 50 /- 57 PSF MISSILE RATED LARGE AND SMALL 4812F I12 FW784' 1 + 50 /- 57 P5F MISSILE RATED O' PLYGEM WINDOWS 433 FL PRAM ST , PO &OX 559, ROCKY MOUNT, VA 24151 PH: 540-484{344 FX 54044 -660 N_ G m WNfF H jm SHw2Rp Z o N2om d=ai nLU 4 i maLLUm LU N m = N f W pz LLUU a LaI rn La I 001 IT W aa N N m Z v) 3: v ZZ Digitally signed by Hermes F. Norero, P.E. DWEI s: Reason: I am approving this document PGW03( Date: 2015.05.15 13:21:14-04'00' SHEET: 1 OF 5 UNIT MAX WIDTH 53.00' D.L.0 MAX. WIDTH 49 44' 3 4 5 e D 5 3 .0. UNIT MAX HEIGHT 72.00' H 4 .X. A E I 3 4 5 SASH MAX WIDTH 51.25' ELEVATION D10. MAX. HEIGHT 33.25' ASH MAX. HEIGHT 36.31' SEE ANCHOR SEE ANCHOR SCHEDULE SCHEDULE D.L.O MAX. WIDTH 44.31' Kw D 5 3 UNIT MAX. HEIGHT 84.00' SEE ANCHOR SCHEDULE SEE ANCHOR SCHEDULE ANCHOR LAYOUT UNIT MAX. WIDTH 48.00' PLy GEM J WINDOWS 5 433 N MAIN 5T, PO BOX 50, F ROCKY MOUNT, VA 24M 3 4 H 54044"346 FX 540-464-6W 0. D.LO. MAX HEIGHT m w Y = 45.56' a ~ SASH MAX. HEIGHT 35.88' a w o< 6 LL 4 `x- 6w Lw cc m< So 3 4 5 F4 W 00, w > d mw0 w mWday N 3 4 C4 I T Z 5 m u V) SASH MAX. WIDTH 46.25' Z u Z ELEVATION O 3: H o v w n o N U_ EDGE HEAD SILL JAMB O.C. CORNER INSTALLATION QTY PER SUBSTRATE EMBEDMENT DISTANCE O.C. DISTANCE O.C.015TANCE DISTANCE DISTANCE ANCHOR TYPE TYPE LOCATION IN.) IN.) IN.) IN.) IN.) IN.) 8 SELF -TAPPING FIN I STEEL STUD 3 THREADS N/A 12 12 9 4 3/16' ITW TAPCON FLANGE 1 CONCRETE/MASONRY 1.25 2.5 20 18 4 10 SELF -TAPPING FLANGE I1 STEEL STUD 3 THREADS N/A 20 18 4 LL . m Z CA Z J V7 N Z of YLL oN 3 _= QZ 0 0 2 OF 5 3/16' ITW TAPCON INSTALLATION ANCHOR CONCRETE/ MASONRY BY OTHERS CAULK BETWEEN CONCRETE/ MASONRY A IX WOOD BUCK BY OTHERS IX WOOD BUCK BY OTHERS EXTERIOR FINISH BY OTHERS 1/4' MAX. SHIM SPACE 3 THREADS MIN. PENETRATION BEYOND STEEL STRUCTURE EDGE DISTANCE #10 SELF-TAPPLNG SCREW INTERIOR INSTALLATION ANCHOR MIN 20 GA. STEEL FRAMB46 BY OTHERS SEE GLAZING 1 1/4' MIN. DETAIL 1 r EMBEDMENT PERIMETER CAULK SHIM / 1 r SHIM SPACE O.A. BY OTHERS WINDOW HEIGHT i SEE GLAZING INTERIOR EXTERIOR DETAIL g VERTICAL SECTION 3 HEAD - IX WOOD/CONCRETE/MIASONRY 4712 FLANGE EXTERIOR SEE GLAZING DETAIL 1 O A. WEIIW HEIGHT STRUCTURAL GRADE SILICONE BY OTHERS INTERIOR 1/4' MAX. SHIM SPACE 3/4' MIN. EDGE DISTANCE EXTERIOR SHEATHING BY OTHERS EXTERIOR FINISH BY OTHERS O.A. PERIMETER CAULK WINDOW BY OTHERS WIDTH p HORIZONTAL SECTION 3 IAMB - STEEL STUD FRAME 4712 FLANGE 1 1/4' MIN. EMBEDMENT 1/4' MAX. CONCRETE/ MASONRY BY OTHERS SHIM SPACE CAULK BETWEEN CONCRETE/ MASONRY 6 IX WOOD BUCK BY OTHERS INTERIOR 1X WOOD BUCK BY OTHERS 3/16' ITW TAPCON INSTALLATION ANCHOR 2 1/2' MIN. EDGE DISTANCE BY OTHERS 1X WOOD BUCK+- • SEE 6LA2ItJ6 BY OTHERS - DETAIL 1 BY OTHERS EXTERIOR FINISH CAULK BETWEEN EXTERIOR PERIMETER CAULK CONCRETE/ MASONRY 61X O.A. BY OTHERS WOOD BUCK BY OTHERS f WINDOW CONCRETE/ MASONRY BY OTHERS NTH A VERTICAL SECTION C HORIZONTAL SECTION 3 GE SILL-1XWOOD/CONCRETE/MASONRY 3 JAMB 00%MAwNRr 4712 FLANGE PLYOEMWINDOWS 433 N NAII+ST. ro AOX 559, RoCIY YOLW. VA 24151 PR 540-+e4e346 FX 540-4&4-6643 comm 0-4> X w S.eO ut w.C c 0 co w < M S G w N 7 - Y ui O A Ji- d m w m cl 1{FJ N_ L7 NN LL F _ N-tom. H A y•••* PROF`` N m m1 w N Z C 3L u- -c FN" pN 3%D =S vZ n U SHEET- 3 OF 3 THREADS MITI. 1/4' MAX. PENETRATION BEYOND SHIM SPACE SHEATHING STEEL STRUCTURE 8 SELF -TAPPING SCREW 3/4' MIN. BY OTHERS INSTALLATION ANCHOR EDGE DISTANCE EXTERIOR FINISH MIN 20 GA. STEEL FRAMING BY OTHERS BY OTHERS 8 SELF -TAPPING SCREW PERIMETER CAULK a INSTALLATION ANCHOR BY OTHERS MIN 20 GA. STEEL FRAMING BY OTHERS O A. 1 1/4' MAX. 3/4' MM 3 THREADS WINDOW SHIM SPACE EDGE DISTANCE PENETRATION BEYOND HEIGHT SEE 6LAZIING— f STEEL STRUCTURE SHEATHING'-. DETAIL 1 EXTERIOR INTERIOR BY OTHERS ._ ... ', ..: EXTERIOR FINISH :.. BY OTHERS y PERIMETER CAULK O.A. BY OTHERS WINDOW WIDTH F VERTICAL SECTION GQ HORIZONTAL SECTION 4 HEAD -STEEL STUD FRAME 4 JAMS - STEEL STUD FRAME 4712 FIN 4712 FIN SEE GLAZING DETAIL 1 EXTERIOR O.A. WINDOW HEIGGHT 1- 1 INTERIOR 1/4" MAX SHIM SPACE PERIMETER CAULK 3/4" MIN. BY OTHERS EDGE DISTANCE EXTERIOR FINISH BY OTHERS MIN 20 GA. STEEL FRAMING BY OTHERS SHEATHERS BY # 8 SELF -TAPPING SCREW OAR' 3 THREADS MIN. INSTALLATION ANCHOR PENETRATION BEYOND STEEL STRUCTURE VERTICAL SECTION 4 SILL - STEEL STUD FRAME 4712 FIN EXTERIOR VERTICAL SECTION 4 MEETING RAIL ok PLy GEMWINDOWS 433 N MAIN ST. FO WX 09, ROCKY MOUNT, VA 24IN PR 540-494i344 FX 74GA44-66&3 INTERIOR O q1+1 N SEE GLAZII,* w S2^ g vi m DETAII 1 w = at = x a W- j NN. 0m-C 4D Lu z N Nft Q Z a x Nat mwc r m EXTERIOR W N N o Z m Z Lu O Z F-i ZO c=i uH Lu Lvu) o21 INTERIOR LL 3t ZCA 3 Lu NOC7°Z m fV $ _ _ 'i Z 0 o v WG #: PGW036 IEET: 4 0F 5 1 f MAR I 2016 BOUNDARY SURVEY- --` Legal Description: Certified to/ for the exclusive use of. Flood Insurance Rate Map: atI5, BELAIR RULAT, --dmX b the pl., I...Saoch- Caa, nuun• tunbcr. 120294 Pa L OD70 th—f6 r—,dad m Plat Book 9, PM. 33 0—sh Emb.- Hams ;_Dons, Inc S.M. F flood kr. 1 e Rom X4, ofthe public,ec-I& of SemoW1 Carry, FImds- - CtIy Titk S—ir ,LLC mP AI Itan \aims] 7-de I D—d Sep,entbc, 214 2007 FI-d lane - X LOT- 4 PROPOSED AREA LOT-9 TO REMODEL/NV N90 00.00 E 125.00- (M Frr ro B N90 00'00 E 125. 00' (P) r Sa fac f z• L9/ 761 a r.n• c n aea 1. n CLYVL fi A p 1 f0 73 e7• » 8 LOT- 5 &20• m• - z7 yEs. 0. GONG A P9 "° 4. 2d gcRE DIs aos N of I C y OO Y1C RE * 80g . g° o . LOT-10 dos 00 R 00 4.o0 o 37 b0• •-GANG O P OOORf4£'. 00 K• ViU) 74- 69• _ IS FN 8M6702• e 700 , N 7/2• N90 00'00'E 125.00' (P%% W N895922125.03' (M) EDGE OF PAW -MEW N COLRT $$ ET 60. 00' TOTAL R IV PER PLAT) w ASPHALT PAV MENT SCA& 130 PARCEL ID# 31-19-31-503-0000-0050 SCOPE OF WORK THIS PROJECT CON515T IN CONVERT EXISTING DODLE GARAGE IN A LIVING AREA WITH ONE BEDROOM, ONE BATHKOOM, AND OTHERS AREAS AS SHOWN IN THIS PLANS. NEED ELECTRICAL AND PLUMBING WORK. MECHANICAL WOKK 15 EXISTING. PARCEL I D# 31-19-31-503-0000-0050 NOTES: f3Y- APR 2 0 2019 DE51GN FARAMETEK5: fto Basic Wind Speed (3 seconds gust) ......140 MFH Wind importance factor ......................1.0 Building Category ............................... II Wind exposure ............................... ± 0.18 Design wind pressure ........................ 30.51`5F CON5TRUCTION CLA551FICATION: Construction type ............ V '1V11 Reoidential Alteration - Level 2 Unprotected, Un5prinklered Exterior construction ..... Blocks Roof and decks .....Wood decking / 5hingle5/ Truss Existing area ................. 672 S.f. ADDITIONAL AREA ........ 0 5.f. "c SANFORD 1 6 - 7 7 4 TH/ 5 PLAN,5 HA BEEN PE5/GNEO /N ACCOPOANCE W/TH ANO MEETS THE REQUIREMEN7-5 OF ALL APPL/CABLE FOLLOWING COOE5.- FL09/ 0A BUILDING CODE2014 FLOR/DA BUILDING CODE EXI57/N5 13UILD/N65 2014 NA TIONAL ELECTRIC CODE ( NEC) 2011 FLORIDA PLUMBING COOE2014 FLOR/DA MECHANICAL COOS 2014 FLOR/DA FIRE PREVENT/ON CODE 2014 - 57-H ED/T/ON AND ALL APPLICABLE LATE5TCOOE5 DESIGN GROUP 473 CITRUS LN MAITLAND, FL 32751 P (407) 651-2950 F (407) 681-2951 Date: 04/ 10/ 2016 Thompson Engineering Group. Inc. dP I 4 L Michael omvoon. PE No 24'-0" TA/C 99-ro SLIUING DOOR SLIDING DOOR FXl,S_M-6 FLOOKP 1/4" = 1' R"ll" I i NOTE: ALL INTERIOR CEILING MUST BE INSULATED WITH R-30 GATT INSULATION 6'-71/2" 2'-1" L NEW \ 3066 j 24'-0" XISTI C l A/C EXISTI NC A/C 4'-3" 5'-0" 2868 NOTE: ALL EXTERIOR WALLS MUST HAVE FURRING 5TRIP51"X2" PT AND INSULATION TYPE R-4.2 PAPER W/ VAPOR BARRIER 9'-6" EXISTING 5'-2" W. NEW BEDROOM WINDOW 36X63 11'-0" / 11'-6" ol- DINc SANFORD 6— 77 b A, 1/4" = 1' 1) DE51GN GROUP 473 CITRUS LN MAITLAND, FL 32751 P (407) 681-2950 F (407) 651-2951 Date: 04/10/2016 ThompSon,Engineering Group. Inc. 4ichael Thompson. PE 0 A/C NOTES: REMOVE ALL EXISTING DUCTS AND REPLACE FOR NEW AS INDICATED ON THE PLAN r-= I ry i T1\L 1,4 Tin ryic Kil-- 1/4"=17 VENT TO ROOF / t / 21 TO EXISTING 2„ I 02 SEWER Z51NKCONNECTION SINK ' 0 2'I1 2" TOIL T P13" 0 2" 0 2' SHOW R WASHERf "ZO PLUMBING NOTES: THIS DIAGRAMMATIC PLANS IS WITH THE PURPOSE OF TO SHOW CONVENIENCE LAYOUT. THE ENGINEER OF RECORD BEARS NO RESPONSIBILITY FOR IT ACCURACY. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE REQUIREMENTS AND LOCATIONS OF EQUIPMENT AND PROVIDING AND INSTALLING COMPLETE SYSTEM SERVICES AS MAY BE REQUIRED BY THE CODE 1 PLUMBING CONTRACTOR SHALL BE USE SANFORD FBC-RESIDENTIAL 2014 CODE FBC 2014 CODE FLORIDA PLUMBING CODE 2014 1 67 7 4 AND ALL OTHERS APPLICABLE LATEST CODE. DE51GN GROUP 473 CITRUS LN MAITLAND, FL 32751 P ( 407) 681-2950 F ( 407) 681-2951 Date: 04/ 10/2016 fhomp5on Engineering Group. lnc. T Y y Hichael Thompson. PE 3 s XISTI C l A/C rK !rU_t-71EV-EIEC-r-k CAL PLAN 1/4" = 1' LEGENP PANEL RECEPTACLE IGFIC GFIC RECEPTACLE 240 volts RECEPTACLE 240 V. CEILING LIGHT 1 EXHAUST FAN 5 SWITCH 52 DOBLE SWITCH EXTERIOR LIGHT OO 5MOKE DETECTOR ELECTRICAL NOTES: TRU55 OR J015T X 4" wood Stud 016",or 24" 2" x 4' P,T. ATTACHED TO THE FLOOR W/ TAPCON 5CREW5 1/4 x 2 3/4" min AK27 DY WALLSTyr.) N.T.5. THIS DIAGRAMMATIC ELECTRICAL PLAN IS WITH THE ALL RECPTACLES MUST DE PURPOSE OF TO SHOW LIGHTING AND CONVENIENCE TAMPER -RESISTANT OUTLETS ONLY THE ENGINEER OF RECORD BEARS NO RESPONSIBILITY ARC -FAULT PROTECTION IS FOR IT ACCURACY, REQUIRED FOR RECEPTACLES THE ELECTRICAL CONTRACTOR IS RE5PON5113LE FOR VERIFYING THE REQUIREMENTS AND LOCATIONS OF ELECTRICAL EQUIPMENT AND PROVIDING AND INSTALLING COMPLETE ELECTRICAL SERVICE AS MAY DE REQUIRED DY THE CODE ELECTRICAL SERVICE RATING AND CONDUCTORS 51ZE5 TO DE DETERMINED DY ELECTRICAL CONTRACTOR PER NEC 2011 AND FDC 2014 SANFORD OUTLETS OUTSIDE, KITCHEN AND 13ATHROOM5 TO DE GFIC OZ pARTIZ AND WATERPROOF 1- ALL SMOKE DETECTORS TO DE HARD WIRED AND # 6 774 INTERCONNECTED it 1) DESIGN GROUP 473 CITRUS LN MAITLAND, FL 32751 P (407) 651-2950 F (407) 681-2951 Date: 04/10/2016 Jlompson Engineering Group. Inc. ;r Michael Thompson. PE 11 EXISTING WALL- C1(I I INv SUVING-DOORS TO BE REMOVED AND FILL THE OPENING -WITH BLOCKS ri Cf} • co I J kf F =_HEADER EXISTING "U" LINTEL 3068 I== NEW 13L• CK WALL III' I 5 REBAR FIX A #5 REBAR TO THE CONCRETE FLOOR MI " N 6 IANDONTOPTOTHE U1 LINTEL MIN. 611 FILL BLOCK CELL W/ CONCRETE 3000 PSI NOTE: THIS SLIDING DOORS HAS A "U" LINTEL ON TOP THE LINTELS REMAIN AS IS. JUST REMOVE THE GLASS DOORS AND FRAME AND COVER WITH BLOCKS TO MATCH EXISTING BLOCK PATTERN. CEILING LINE—) EXISTING LINTEL_ 3,-011 AV 8'-311 y F.F. NEW WINDOW INSTALLATION tiv S.r,*„ORD 1G-774 1R5T FLOOR MIN. REQUIREMENT EGRESS CLEAR OPENING WIDTH 33.625 CLEAR OPENING HEIGHT 24.375 CLEAR OPENING S.F. 5.692 MIN. S.F. CLEAR OPENING > 5.00 r DESIGN GROUP 473 CITRUS LN MAITLAND, FL 32751 P (407) 681-2950 F (407) 681-2951 Date: 04/10/2016 hompeon Engineering Group. Inc. r' chael Thompson. fE 5 COPS' -- j RECORD - r r APR 2 0 2016 JBEYY - L _ - REVIEWED FOR CODE COMPLIANCE EXAMINER---- DATE ' r • . , - i nwr O1VISlON ' SANFORD BU! E I ' A PERMIT 196UED SHALL BE CONSTRUED TO BE A r 1 LICENSE TO PROCEED WITH THE WORK AND NOT ASAUTHORITYTOVIOLATE, CANCEL, ALTER OR SETASIDEANYOFTHEPROVISIONSOFTHETECHNICALCODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT i+ THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION TNS OF T PLANS-, r 1 _ CONSTRUCTION OR VIOLATIONS OF THIS CODE L ' SANFop' D OFPAR _ — — F' r A 1 1 a i