Loading...
HomeMy WebLinkAbout212 Colonial WayMICR 6 t sY: Job Address: 21 L CITY OF SANFORD ' S BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: / Documented Construction Value: $ 2, 3 O _W Parcel ID: &k 1q' r 0 -,SN - 1006, Type of Work: New Addition Alteration Description of Work: Plan Review Contact Person: Phone: wfl- ;n--b-Fax Name' & I ULA - Street: 11 City, State Zip Name hm Street: City, State Zip: Name: Street: City, St, Zip: Bonding Compan; Address: Y1rl r/r! I i o VI Jf l Historic District: Yes No M Residential IN Commercial Repair Demo Change of Use Move Title: r"y-G'( d Ary)(dii10.,&M Phone: ucj - 272- 1E 12 Resident of property? or Information Phone: L6. /`S Z3L7X Fax • n St to License No.: C-NCO2Ydra gineer In mation Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to.meet'.standards';of-all'laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5t° Edition (2014) Florida Building Code A: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental{entities such as water It- rmanagementdistricts, state agencies, or federal agencies. , II r Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida L'en Law, FS 713. r The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the ex`eeuted contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all appliepble laws regulating constru O[on a d zoning. Signature of Owner/Agent Date tI y 11 Print Owner/Agent's Name ' \ Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID of Coqt dtor/Agent Date Print Contractor/Agent's Name ware -- MY COMMISSION d F 257 , EXPIRES: FebrUary 19 Bonded ihro Notary Pub1c Unde-den ContrRctor/Agent is rodticed ID r 0 -/ Personall Known to Me or Type of ID l 1 BELOW IS FOR OFFICEMSE ONLY Permits Required: Building Electrical MechaniLal PlumbingD Gas tRoof Construction Type: Total Sq Ft of Bldg: 4 Occupancy Use: Flood %Zone: Min. Occupancy Load: # of Stories:' New Construction: Electric - # of Amps Plumbing - # of Fixtures i ~ Y` Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit/Yes No APPROVALS: ZONING: ENGINEERING: UTILITIES: FIRE: WASTE WATER: BUILDING: !ir 3-/D• I (r COMMENTS: 54 W i\/iK- ` &A,0,4c )qw,+t CA0 Btr cbog0 t U N Dt4P_ 771' SA•M& ttZaNt t f Revised: June 30, 2015 Permit Application REQUIRED INSPECTION SEQUENCE 1 -7 if BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In REVISED: June 2014 Addraee- % 1 i 1'e tram_ .. — . i ELECTRICAL.P.ERMIT ` v w e- - f Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final u.W 4ua4yl9.1 ,. •—_.- s'.' a'"r'$".``r!'f+r ry....Mw..:'wy,.,r. Min Max Inspection Description Plumbing Underground lumbing SewerP------------- Plumbing Tub Set FinalfflPlumbing F ECHANICALIEERWT IinMaxInspectionDescription Mechanical Rough7MechanicalFinal Min I Max Gas Unde Gas Roug Gas Final ALTAMONTE SPRINGS 1000 Sunshine Lane Altamonte Springs, FL 32714 1-800-381,-7638 r Orange, Osceola, Semmolc, Lake, Sumter, Highlands, Volusia, Flagler & Surrounding Counties TAMPA 2260 Massaro Blvd. Tampa, FL 33619 813-664-0009 Hillsbourgh, Pasco, Pinellas, Polk, Alachua, Marion, Sarasota, Manatee & Surrounding Counties TALLAHASSEE 2912 Crescent Dr. Suite 6 Tallahassee, FL 32301 1-800-382-7638 Leon, Wakulla Surrounding Counties By Discovery Marketing & Distributing Inc. 6505 Edgewater Dr. • Orlando, FL 32810 407-523-0775 • FAX 407-294-2852 www.myfewa.com Power of Attorney Date: I City or County: Permit# Site Address: 2 1 Z 5TI I Description of work: Contractor: License: Phone# As contractor for the above referenced permit, I hereby authorize LC q(-2 to sign documents related to the above mentioned address. Signature of License Holder State of Florida Orange County The Foregoing instrument was acknowledged before me this l` 20 16. by / C—Qil ; 5 1't Q , v>7 a Who is [_ is personally known to me or has produced as identification. Notary Signature GREEN I MUTIONS A06 day of G 0 At" Notary Public Stet- of Florida y f Deborah Willis dP My COmmi3SIon FF 234581OFnExpires0&13/2019 1 MELBOURNE 1420 S. Wickham Rd. Melbourne, FL 32904 1-800-382-7638 Brevard, Saint Lucie, Martin, Indian River, Palm Beach Surrounding Counties SOLATUBE. ( LENNOX 2/25/2016 a vid Jat->,isa, CF;A P ROPEI TY SE1JIItvCx.E C:(hJMiY, FIiORiOA Parcel: 36-19-30-534-0700-0090 SCPA Parcel View: 36.19-30-534-0700-0090 Property Record Card Parcel: 36-19-30-534-0700-0090 Owner: SOLA MALAVE ELBA I Property Address: 212 COLONIAL WAY SANFORD, FL 32771 Property Address: 212 COLONIAL WAY Owner: SOLA MALAVE ELBA I Mailing: 212 COLONIAL WAY SANFORD, FL 32771-4313 Subdivision Name: HIGHLAND PARK Tax District: Sl-SANFORD Exemptions: 00-HOMESTEAD (2015) DOR Use Code: 01-SINGLE FAMILY Value Summary 2016 Working 2015 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 68,308 68,790 Depreciated EXFT Value 200- 200 Land Value (Market) 21,349 21,349 Land Value Ag - » Just/Market Value$ 89,857 Portability Adj Save Our Homes Adj #0 Amendment 1 Adj Assessed Value- - $89' 857 90,339 90,339 - Tax Amount without SOH: $1,007.00 2015 Tax Bill Amount $1,007.00 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOTS 9 + 10 BLK 7 HIGHLAND PARK I PB4PG28 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund _- 89 857 50,500 39,357 i Schools 89,857 : 25,500 64573 i City Sanford 89,857 50,500 ' 39,357 SJWM(SaintJohns Management) WaterWater .._ me. - ..,.,__.,._ 3$89,857 j 50,500 39,357 County Bonds L_ 89,87 50,500 39,357 li Description Date Book Page Amount Qual-fied Vac/Im WARRANTY DEED 4/1/2013 08025 0346 91,000 Yes Improved SPECIAL WARRANTY DEED 5/1/2012 i 07787 0141 35,300 No Improved CERTIFICATE OF TITLE 2/1/2012 07717 11302 100 i No Improved QUITCLAIM DEED 10/1/2003 05169 0978 100 No Improved QUIT CLAIM DEED 5/1/201 04107 0624 Improved WARRANTY DEED 7/1/1994 02801 0811 76,000 Yes Improved i PROBATE RECORDS 1/1/1993 02532 1 1792 i #100 No Improved ADMINISTRATIVE DEED 10/1/1990 02233 1264 75,000 No Improved WARRANTY DEED 1/1/1979 01205 0621 43,000 No j Improved WARRANTY DEED 1/1/1976 f 01107 0938 20,000 r No Improved Find Comparable Sales within this Subdivision http.//www.scpafl.org/ParcelDetaillnfo.aspx?PID=36193053407000090 1/2 2/25/2016 SCPA Parcel View: 36-19-30-534-0700-0090 Land Method Frontage Depth Units I Units Price Land Value FRONT FOOT & DEPTH 119 92 0 230.00 21,349 Building Information k Description YearBuilt I Fixtures i Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective. 1 SINGLE 1952 12 852 2,313 2,097 CB/STUCCO I $68,308 130,111 Description ArealiFAMILYFINISH ENCLOSED PORCH 240 FINISHED I j ENCLOSED i 1 PORCH 216 I f I I FINISHED UTILITY 216 1 I FINISHED i i I i BASE SEMI 304 FINISHED ENCLOSED W jj I I I II PORCH 2961 I FINISHED ENCLOSED I PORCH 189 I FINISHED Permits Pew rmit # Type Agency Amount CO Data Permit Date T No data to display Extra Features j Description Year Built Units Value New Cost -- SHED 110/1/1963 I 1 2pp l ----- 500 http:/twww.scpafl.org/ParcelDetaillnfo.aspx?PID=36193053407000090 tit SITE COPY FLORIDA SOLAR ENF„RGY .ENTER" Approved Solar Energy System Approval Date: FEB 2010 FSEC # 500170B DISTRIBUTOR SYSTEM Solene Solene/Aurora 40DC 950 Sunshine Lane Altamonte Springs, Florida 32714 This system was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida Standards Program.for Solar Domestic Water and Pool Heating Systems (FSEC Standard 104-05) and was found to meet the minimum standards established by FSEC. North Central South The calculated Florida Energy Factors for this system are: 3.2 3.5 3.5 DESCRIPTION Collector Manufacturer Model Number Units -Total Rating (Btu) I . Solene Solene/Aurora SLAR-40 1 37,900 2. 3. 4. Tank Manufacturer Model Number Capacity (gal) Type: Direcj/ 10 1. Lochinvar FTA-082K 80 Rheem 81RV80-1 80 USANFORD2. 3. AO Smith Sun 80 80 4. Any Equivalent UL listed Tank 80 1--=7 1 1 Pump Manufacturer Model Number Power Draw (Watts) Rated Power 1. TACO 006BC4 75 1/40 H.P. 2. March 809-BR 30 1/100 H.P. 3. Grundfos UP1518 85 1/25 H.P. 4. Wilo Star 8 50 1/25 H.P. Controller Manufacturer Model Number Type: Differential controller 1. Goldline GL-30 2. Goldline GL-30LCO 3. STECA TR0301 U Freeze Protection SANFORD BUILDING DIVISION I . Freeze prevention valve A PERMIT 196UED SHALL BE CONSTRUED TO BE A 2. Manual drain down LICENSE TO PROCEED WITH THE WORK AND NOT AS Al ITHQRITV T-Q VIOLATE, GAAIGE IATCD OR SET Other Major Components ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL 1 COMPLIANCE PREVENT REVIEWED FOR CODE THE BUILDING OFFICIAL FROM THEREAFTER 2 REQUIRING A CORRECTION OF ERRORS IN PLANS. PLANS EXAMINER CONSTRUCTION OR VIOLATIONS OF THIS CODE 3- lD [to - DATE 10719(: Iart'J;t.Ik'IW,C,VoA.FI ,I; ilk" i`_'1 il' •'II; :I-03,i-Ik%V F.va QI-638-I0I0 .ucfedu UN: t, m Sr',TFNI f FL(VtCV, • A4Ecx h Ck't'(:;mh-jroNiirw,rvi A, TY'1v' &.sir,ar.. A Rr:4 MT(Tuo cw -.mt Uw twin of Crmrwi Ftcwtic>•-A FLORIDA SOLAR ENERGY CENTER" Approved Solar Energy System Approval Date: FEB 2010 FS EC # SOO I 70B 0)\LDIIVC SANFORD' A, 1 6 - 7 1 1 A-, [CA k•4, ()TTI(,sr.u,,ITIINCr,V,4TPTA-,r,,,,r. Uw-Lcmp -A fw,,A-,,,, 1,;,xruTc or -ftf UNvvu-PYof Crmk-k Vi-or IA k Solaraide'Storage Tank and Sectrk Storage Water HeatersIbr Solar Applications • • • A.d c; Available In 80 and 120 Gallon Side Conned and Top Connect Models 6-Year Umited Tank and Parts Warranty` Brass dram valve Choice of two models... storage tank or single element water heater, both specially equipped for installation with residential direct solar systems Patented R-Foam insulation process Special threaded stud located near the outlet for attachment of tank sensors Temperature and pressure relief valve included Collector feed and return fittings located at front of tank for convenient installation Isolated taft design for better heat retention High efficiency heating element I me Ias• tank lining resists corrosion and prolongs tank life Cold water inlet brings cold water to tank bottom to prevent mixing with heated water Anode rod equalizes aggressive water action for prolonged tank rife Cold water inlet, hot water outlet, reli valve and anode rod at top of tank f r easy access and fast, economical ANinstallation Automatic temperature control o Over temperature protector Fpq See Residential Warranty Information Brochure for complete warranty information. Cods ooe a t pfl OA.E national •'•9• rate aAtyKVel LDINC FO 80 81VR80-1 6000 W 58-3/4 24-12 192 R-17.3 120 81VR120-1 6000 W 62 284/4 336 R-16.7L L 80 81VR80-T Storage only 58-3/4 24-1/2 192 R-17.3 120 81VR120-T storage ONy 62 28.1/4 336 R•16.7 T 80 81VR80TC-1 6000 W 5"4 24-M 192 R-17.3 A 120 81VR120TC-1 600D W 62 28-1/4 336 R•16.7 80 81VRSOTC-T 58-3/4 24-1/2 192 R-17.3 120 81VR120TC-T 62 28-1/4 336 R-16.7 All units furnished standard 240 vok AC. TOP CONNECTUnitsareshippedwitha4500wattSIDECONNECT elernent. If twa*V elements of dkfer. Ratsed r flan the bottom, the boutlet the solar Collectorantwattagesthanthosestrewnare Peel heW pltp scale A specter threaded stud 1s also welded b the tank behind 71e demanded by :one requirements, lower sky opening. Lev voit"s they must easpecifically requested. and snskle vAre run this point o mo llSdaraidemodelsmodall current fhlolrph the solar d d oir>,ide (t1e pdcd and out she top n%wirements for solar ti ww tanks, YS%- for any =*ot oonnectlon. The tanks are Rheemps tined and are Aspecial threaded stud is also welded to the tank new designed to operate up to 150 PSI. b• outlet for stachment of tank sensors. These units are designed to meet or exceed ANSI American National Standards i r'i i r iulaoEaep NOfO1^!+• oouecro•.es o lemma VM6 eOLDOV" Instttuto) requirements and have been tested accordav to es acc rap o•en••o caumse ti O.O.E. test procedures and ec1OM w rm I---Bmeetorexceedtheenergyetii. ace w CIe r is of NfAEncyequirertt CA, A r.( •_ J ASHRAE standard 90. BOCA oato MOT , N un tuT, o'e•.a ,, arnnw •TOr C-ONf.CIpN aua•'MJ,T. Code and all state energy etfi- COULeclim t ciency pertnrmance Criteria for A ; atoeuinw ,o.• COLD rY•a • NUT energy consuming applianc es. A .ram score U. a ., Before purchasing this r Omas p 1 appliance, read Important aarsoaSTEM Ao energy cost and efficiency r vrarea COCULA oa t ua. VolTaoe information available from u1' your retalder. SIDECONNECT KYWAM • • TOP CONNECT Rheem Water Heaters • 101 Bell Road, Montgomery, Alabama 36117 PR1NrE0 IN U. S.A 09r02 WP FORM NO 101.1 R•v. 11 Steca T-R . 03 01 lJ . Digital -,accuracy vides r2kaf time op -ni in619ffi ak ires at up to three LocationsLSDpro '-.. .;:... • ,:.v3 ft-< ',.-.-;,,• .' Ariirrtated.reor6eiitation ofisysl i1 vetat3on Sophisticated, -monitoring a6d—.. atJl. Giiagnostics Fused output,protection folr pump circuit Varistou high voltage spike..proiktion RTD.type '1'000 0-sensors - Adjustable -high limit temperature `otstdrage tank Evacuated tube &freeze re&61;hi6n,6ictions Vacation overheat protection Accessible side -mounted on, off, auto switch Three temperature sensor inputs; one 120 VAC output Pump protection activated when collector reached 266 °F 11,%lowaeuresensorWrt bds php4ystlte tMrretattra wales and aJlf. a. g. short tiraalt kmnttp- ton tsr SY5 - systm en or add.y hatcton Ald-freeee fimctlon Q sdec*V the terrWahee trot 4 /Y Tube collector functbn 5," the mntinaan storage tank Ca C us Qj Solar orctat symboh Q OePNrt rtxssaga'htadmumsWragetattktwWwaturehas bW Madlar Wa—V display if (auks occur, a 9- Short draft, arkenupton or M - system error pepktys message (or etraporatbn of the Celle= tWd D'~ massage roe suffioent heat supply 7:1CE Spezialized for the USA Made in Germany Steca is tS09Q01" and .15014001" cerNfled and registered 4pDSA OFD Steca GmbH Mammostrasse 1 D-87700 Memmingen Germany Tel.: +49(%833185580 Fax.: +49(0)8331855812 www.stecasolar.com Steca TR 0301 U The Steca model TR 0301 U differential temperature control provides automatic, safe and reliable operation of domestic solar water heating systems. The TR 0301 U output is wired to a pump that circulates the heat transfer fluid between the solar thermal collectors and the storage tank during the course of the day. This microprocessor -based TR 0301 U utilizes two RTD (resistance temperature detector) type sensors to mo- nitor collector and tank temperatures with digital accuracy. The LCD gi- ves the homeowner a variety of real time information including system temperatures at up to ree separate locations. The consistent use of simple pictograms ernu ease of operation and troubleshooting. In addition to the prim function of turning the circulating pump on and off during the day, TR 0301 U provides important diagnostic and safety functions. For exa ple, the LCD pictograms will indicate fault con- ditions such as sensor its or pump failures. The installation manual also clearly describes the fault symptoms, possible causes and remedies. The TR 0301 U features a total of three inputs for recording tempe- rature and one 120 VAC output for the circulating pump. Varistors protect the sensor inputs against high voltage spikes. The load side is fuse protected. The control package includes two RTD type sensors, a seven foot line cord and a spare fuse. An optional third sensor displays the upper tank temperature and eliminates the need for an analog thermometer and fittings. The numerous additional features of the TR 0301 U include an adju- stable high limit (32` F - 205' F), an evacuated tubO collector function, vacation overheat protection to minimize collector stagnation, and a freeze -recirculation option. Temperatures can be displayed in either Fahrenheit (°F) or Celsius (QC). Technical • 0301 U Opeeating voltage 120 VAC. 60 Hz ' optional 240 VAC, 60 Hz) Self consumption S 0.001 HP 3 inputs for temperature Pt1000 recording 1 output Switch relay, Switching performance max. 0.5 HP (120 V—); 1 HP (240 V—) Fuse protected Fuse: UtWfuse 215.004 Line cord 7', 18 AM rated at 221 'F Display Animated LCD display, 2-color round Protection class IP 20/DIN 40050 Permitted ambient temperature 32 to +113 °F (0 to +45 'C) Installation Wail -mounted with screws Weight 19.54 oz (0.55 ) include cable Case Recydable 3-piece plastic case Dimensions 6.3"(W) x 6.18"(H) x 1.85"(D) 160 L x 157 8 x 47 H mm) Temperature sensors 2x Pt1000 Collector sensor. 59 inch (1.5 m) silicone cable with bushing Measuring range up to +356'F (+ 180 "C)) Storage tank sensor. 11.8 inch (0.3 m) twisted single conductor flat surface sensors with compression cable tug Measuring range up to 222 "F (+105 *Q) Availabie from: Dimensions I I S stem setup optionan Single -storage solar system Standard, wklwut connection cable 16-7if out temperature sensor Aput power connection rtput pump clot net ocr•unied ains connection cable imp socket Prefabrkated; with mains connection cable and pump socket Storage tank sensor Pt1000-Lug Temperature sensor included Collector sensor. Pt 1000-Probe Srvra GmhH • Mammostrasse 1 • 0-87700 Memminaen • Germanv • Fon: +49 (0)8331 8558 0 • Fax: +49 (0)8331 8558 12 • www.stecasolar.com Wet -Rotor, In -Line, Single Stage, Maintenance Free; Circulator Pumps Submittal Data 60 C cle JOB orCUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: DATE: APPROVED BY: DATE: ORDER NO: DATE: SPE&FICATION R F: QUANTITY TAG NO.: MODELNO., . GPM , FEET, VOLT PHASE COMMENTS Technical Data Mounting Positions FLOW RANGE: 0 to 17 U.S. GPM HEAD RANGE: O to 16 Feet MOTORS: 2 Pole, Single Phase MAXIMUM FLUID TEMPERATURE: 150-F (6r% Maximum design temperature. MIN. FLUID TEMPERATURE for UP15: 384F (2•C) TIMER: 24 hours 3 po3Mons (ONfMER/OFF) 15 minute Interval. LINE CORD. Six-foot 18-3 with 5-15P grounded pklg. MAXIMUM WORKING PRESSURE: 145 PSI MINIMUM REQUIRED INLET PRESSURE: At IWF (SrC) 3.0 FL (0.9m) 1.3 PSI. O Rammma ded 4jo 7 DONOT Nwd4bbrStrat InvWkwPoultlan FOR INDOOR USE ONLY Dimensions, and Weights uP15•tossa sr. UP 15.1885 t BT• UP1S10BUC5 Timer 8 Line CordUP1542BSd87UP15-18SU UP1s101AX7 -' OSANFRD,, K o = ...... I r 9 I---11 6 — 7 1 1 o T CF g c Shipping wt UP15-1085/LC & TLC UP 15-1087/ LC 6 TLC 5 6 3/11 631m 611s 51/2 5 % 4 3 73he 3112 3114 4 4 Sweat —112 Sweat — 314* 6.5 7.2 UP15-18B5/LC & TLC 5 63/I. 51/2 3'/2 31/4 4 Sweat —1/27 6.5 UP15-18BT/LC h TLC 63/4 6 % 51/2 3171a 3114 4 Sweat - 314" 7.2 UP1542B5/LC 3 TLC 5 63/14 51/2 3112 31/4 4 Sweat -1/i 6.5 UP1542B T/LC d TLC 6 3/s 6 % 51/2 3131w 3 1/4 4 Sweat - 314* 7.2 UP15-10BUC5/LC b TLC 6112 6314 5'/: 33/u 3114 4 Sweat 1/2' 7.7 UP15-I0BUC7/LC 8 TLC 73/. 63/4 5% 311, 4 Sweat 314* 8.5 UP15-18SU/LC & TLC Sti. 641% 5 Vz 37w1 3114 4 Union - 1'14" NPSM 5.5 W I tJ: All Gimen91ens Oro in inChe& Performance Stainless Steel or Bronze Cons&urkon - Flange, Union, or Sweat Mount I: NONNNNEENEEMI 2. UP15-1087 UP15-10BUCS 41= 1; MEN NIN is .. Vc SIN\ ffi Lrtu7 o7t 7 to7 Electrical Data MODEL VOLTS AMPS WATTS I HP CAPACITOR MODEL VOLTS AMPS' WATTS HP CAPACITOR UPIS- 1085 3 87 115 55 60 4a W/180V UP15-4285 115 74 85 1h5 1010180V UP15- 18SU & 85 115 74 85 4a 10µF/180V UP15-4287 115 74 85 Va 10µF/180V UP15- 18B7 115 74 85 Va 10µF/180V UP15-10BUC517 115 0.55 60 1/25 8µFH80V Materials of Construction DESCRrTIONl 1MATENAL DESCRIPTION MATH711kL kdet Cone. Bearing Plate, Bearing Retainers. Rotor 304 Stainless Steel ORing & Gaskets EP (Ethylene Propylene Can. Rotor Cladding, Shaft Retainer. Rubber) Pump Housing (Volute) on UP15 1SSW5F Pump Housing (Volute) for UPI S-tOB5 6 By, Silicone Bronze C875 UPt5. 1$85 a 87. UP154286 & 87. UP15- 108UCSR87 Volute Retainer SU Model d Stator Mousing Akn*xmIrnpellar PES Composite (30% Glass Filled) Shaft. Upper & Lower Radial Beatings Alumin anOxideCeramic I ThrustBearfrq MetalknprognatedCarbon I TenminalBox Horyla GRUNK3FOS* % Gruedtos Pumps Corporation - ITM W.11sth Terra"* - Olathe. KS 66061 Phone: 913.2273400 - Fax: 913 227.3500 Canada: Oakville. Ontano - Mexice: Apodaca. N L VhJt our weBsfteat www4ran4*xorn 1JP- 34 Rw.9N1 PRINTED IN USA r a:::,,•. TECHNICAL INFORMATION.",`AWI . 1 AURORA Solar Collectors by SoleneT^" so SOLAR COLLECTORS BY SOLENE" TECHNOLOGICALLY ADVANCED ENGINEERING FOR MAXIMUM PERFORMANCE AURORA Solar Collectors are the most technologically advanced collectors on the market today. AURORA features the highest quality materials & state-of-the-art engineering to provide maximum efficiency & durability you can depend on for years to come. AURORA collectors are environmentally friendly, non-polluting and reliable in any environment. AURORA panels are the most important component of any solar water heating system, producing dependable results under any weather conditions. 8 4 3 1. Absorber Plate Utilizing a state-of-the-art sonic weld, copper fins and risers provide superior thermal connectivity between the fins and risers. Revolutionary coating is black chrome on nickel, producing a premium selective surface with maximum efficiency for solar energy use. Easy absorber replacement if needed. Absorbability = 0.95 Emissivity = 0.12 2. Tubing Grid 3/8" copper risers are brazed to 1 " copper mainfolds for optimal flow distribution. 3. Piping Connection 1" Type M copper header. 6 > > 9 s ONLDING SANFOr2D 16-711'1 4. Aluminum Foil and around the side of the absorber plate, Attached to the insulation, acts as a barrier retains the heat of the water in the collector. against out-gasing. DFC-free P.U. meets U.S. and European 5. Solar Glass Glazing A single pane of 1 /8" thick solar glass is patterned to reduce reflection and tempered to maximize strength and durability. Iron oxide content: 0.03°% Solar transmittance: 91 °% 6. Back Plate High -Density Polyethylene Backing; Reduces torque in the frame, is lightweight and eliminates the possibility of any electrolysis issues for maximum benefit. 7. Insulation 1-3/16" polyisocyan u rate foam cast under C7 1le The best investment under the sun! SOLAR HOT WATER SYSTEMS standards. A 3/4" layer of mineral wool protects the polyurethane and provides additional collector insulation. 8. Casing All aluminum extrusion casings create a sleek framewall. Unique extruded profile allows easy anchoring to the roof (shingle, tile, tar) or collector stands. Reinforced corner assemblies to increase rigidity. 9. Gaskets All-around EPDM gasket. Highly resistant to temperature differences and UV radiation. Absorbs the differential expansion of frame and glazing. 1 w., sµ,.{arw it _ AURORA Solar Collectors by SoleneT"^ SPECIFICATIONS AND EFFICIENCIES Models General Specifications AgRu"RA SOLAR COLLECTORS BY SOLE NET" Gross Area (sq. ft.) 31.78 40.38 Net Aperture Area (sq. ft.) 30.53 37.44 Ratio Net/Gross Area 0.95 0.95 Length (in.) 96.48" 117.96" Width (in.) 47.4" 47.4" Thickness (in.) 3.96" 196" Weight (lbs.) 105.8 132.2 v\LDiNc Fluid Capacity (gal.) 1.05 1.2 Recommended Flow Rate 0.6 0.7 SANFORD Test Pressure (psi) 300 300 FpgR C Operating Pressure (psi) 145 145# 1 6 % 11 Efficiency Ratings Clear Day Mildly Cloudy Cloudy Day Clear Day Mildly Cloudy Cloudy Day A (-9° F) 46.1 34.8 23.7 5&5 42.7 29.0 B (9° F) 41.3 30.1 18.9 50.7 36.9 23.2 C (36° F) 34.5 23.5 12.6 42.4 28.8 15.4 D (90° F 22.4 12.4 3.3 27.6 15.3 4.1 E (144- F) 12.0 4.1 0.0 14.9 5.1 0.0 Efficiency Equation [NOTE: Based on gross area and (P)=Ti Toj) Efficiency Equation [NOTE: Based on gross area and (P)=Ti-Taj[ S I UNITS: r1=0.7820-4.28290 (P)/I-0.00484 (P)2/I S 1 UNITS: -q=0.7840-4.28050 (P)/I-0.00484 (P)2/I I P UNITS: r1=0.7820-0.7544 (P)/I-0.0005 (P)2/1 I P UNITS: rt=0.7840-0,7540 (P)/I-0.0005 (P)2/I Y INTERCEPT SLOPE Y INTERCEPT SLOPE 0.8 -4.6 W/m2.° C 0.8 -4,6 W/m2., C 0.8 -0.8 Btu/hr.ft2.° F 0.8 -0.8 Btu/hcft2.o F Ti = Water temperature (T out - T in)/2 F FSEC" To S Ambient temperature F W'0-4 t ene1= Solar radiation Btu/hr/ft? OG-100 Collector AApproved MW In WA rw.TcR sysrzMs OG-300 System Approvals Solene Corporate Headquarters: 950 Sunshine Lane Altamonte Springs, FL 32714 Toll Free 1-800-506-1994 Distribution Centers: Orlando, FL • Philadelphia, PA • Fairfield, CA F D PERMIT NO. CONTRACTOR: Re) I I ISSUE DATE: la IJOBADDRESS: M10' TYPE OF WORK: S01 or U N City of Sanford Building & Fire Prevention Division Residential Permit Card Post this permit in a conspicuous location outside Leave all work uncovered until inspected and approved Approved plans must be posted with permit for inspection Perron expires 6 months from date of issue or last approved inspection PROTECT FROM WEATHER BUILDING ELECTRICAL INSPECT70N TYPE APPROVED REJECTED INSPECTOR INSPECTION TYPE APPROVED RFJECTED INSPECTOR FOOTER INSPECTION ELECTRIC UNDERGROUND STEMWALL FOOTER/SLAB STEEL BOND FORMBOARD SURVEY T U G / PRE POWER SLAB / MONO -SLAB ELECTRIC ROUGH LINTEL / TIE BEAM ELECTRIC FINAL SHEATHING - ROOF MECHANICAL SHEATHING - WALLS INSPECT70N TYPE APPROVED REJECTED INSPECTOR FRAME MECHANICAL ROUGH INSULATION ROUGH IN MECHANICAL FINAL DRY WALL/SHEETROCK PLUMBING LATH INSPECTION INSPEC770N 7YPF APPROVED RFJECTED INSPECTOR FINAL STUCCO/SIDING UNDERGROUND ROUGH FIREWALL SCREW TUB SET FIREWALL FINAL SEWER INSULATION FINAL PLUMBING FINAL FINAL SFR GAS INSPECTIONS ROOF INSPEC770N TYPE APPROVED RFJECTED INSPECTOR GAS UNDERGROUND PIPEINSPEC77ONTYPEAPPROVEDREJECTEDINSPECTOR ROOF DRY -IN GAS ROUGH -IN FINAL ROOF GAS FINAL MISCELLANEOUS FINAL INSPECTIONS INSPFC77ON TYPE APPROVED REJECTED INSPECTOR INSPECT70N TYPE APPROVED REJECTED INSPECTOR PRE -DEMO FINAL DOOR FINAL DEMO FINAL WINDOW FINAL SOLAR PANELS IRRIGATION FINAL FINAL POOL SCREEN FINAL SCREEN ROOM FINAL UTILITY BUILDING FINAL BUILDING (OTHER) MOBILE HOME TIE -DOWN MOBILE HOME FINAL WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES ORFEDERALAGENCIESFBC10533 REVISED: OCTOBER 2014 Inspection Line: 855.541.2112 REVISED: OCTOBER 2014 Inspection Line: 855.541.2112 RC Engineering - Wind Calculations - SL-3C 175 MPH Ultimate Wind Pressure Calculations for Flush Mount Residential Solene Aurora Collector / Ris Category II / Exposure C on 2/12 to 6/12 Pitch Roof Slope Wind Velocity Pressure Calculation per ASCE 7-10 Components and Cladding Part 2 Method 1 Pnet = Pnet30*Kzt*A Ultimate Wind Speed - V i, (MPH) = Nominal Wind Speed - Va,d = V i, x J[0.6] (MPH) = Wind Exposure = Risk Category = Topographic Factor - Kr, = Adjustment Factor for Building Height = 30 ft and Exposure C - k = 175 136 C II 1 1.4 Total Wind Area of Collector - A, Length of Collector (ft) = Width of Collector (ft) = Total Wind Area of Collector (sf) = Quantity of Connection Points per Collector = Effective Wind Area (sf) _ 10 4 40 4 10 Tabulated and Calculated Wind Pressure - Positive Pressures based on Nominal Wind Speed Pnet30 - Wind Zone 1 (psf)@ EXPOSURE C = Pnet30 - Wind Zone 2 (psf)@ EXPOSURE C = Pnet30 - Wind Zone 3 (psf)@ EXPOSURE C** = Wind Pressure for Wind Zone 1 - Pnet (psf)@ EXPOSURE C = Wind Pressure for Wind Zone 2 - Pnet (psf)@ EXPOSURE C = Wind Pressure for Wind Zone 3 - Pnet (psf)@ EXPOSURE C** = 19.2 19.2 19.2 26.88 26.88 26.88 Tabulated and Calculated Wind Pressure - Negative Pressures based on Nominal Wind Speed - Controls Pnet30 -Wind Zone 1 (psf)@ EXPOSURE C = Pnet30 - Wind Zone 2 (psf)@ EXPOSURE C = Pnet30 - Wind Zone 3 (psf)@ EXPOSURE C** _ Wind Pressure for Wind Zone 1 - Pnet (psf)@ EXPOSURE C Wind Pressure for Wind Zone 2 - Pnet (psf)@ EXPOSURE C = Wind Pressure for Wind Zone 3 - Pnet (psf)@ EXPOSURE C** _ 30.5 53.1 78 5 42.70; i _=74.34; _ 109.904 Installation of collectors in specified wind zone is not recommended, and requires site specific structural engineers approval. Note: Plus and minus signs signify pressures acting toward and away from surfaces, respectively. Uplift Force on Collector Connection Fc—ec- = [(Uplift -Collector Weight)/(Quantity of Connection Points)]*Effective Area -Neglect Collector Weigh rota) Wind Area (sf) = 40 Quantity of Connection Points per Collector = 4 Jplift Force per Collector Connection (Ibs/connection) = 743 " Required Lag Bolt Size and Length to Wood Truss Per Latest Edition ASD NDS for Wood Construction W' = W*(Cd)*(Cm)*(Ct) Southern Pine Wood Truss Specific Gravity - G = Withdraw Value for 3/8" Lag Bolt (Ibs/in) and specified Specific Gravity = Embedment Depth (in) _ Embedment Withdraw Design Value - W (Ibs) = Load Duration Factor (Cd) for Wind Load (Ten Minute Intervals) = Wet Service Factor (Cm) in areas > 19% moisture content in-service conditions - Temperature Factor (Cr) in areas with experience sustained exposured to elevated temperatures 125 OF < T < 150 OF Adjusted Embedment Withdraw Design Value - W' (Ibs) = 0.55 352 3 1056 1.6 0.7 e 0.7 827.9 Acceptable Design Value Check = OK - • " Note: These calculations are applicable For the generic drawings labeled as SL-3C. Threaded embedment depth -Mcufot above excludes any roof decking. Z -ni Rick Castillo, PE FL PE #52590 - COA#28345 GAaTIt sus Np. y0 OF r PL fI/!j wLLIIL t-ULLU. I UM v[IVr_ML NU I t5: 1. APPLICABLE CODE: 2014 FLORIDA BUILDING CODE (5TH EDITION) & ASCE-7-10 MINIMUMDESIGNLOADSFORBUILDINGANDOTHERSTRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE 5TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27 ° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. BUILDING NOT TO EXCEED 30'-0" ROOF HEIGHT. CONTRACTOR RESPONSIBLE TO VERIFY ROOF SLOPE. 4.EACH BRACKET SHALL BE FASTENED TO THE COLLECTOR WITH (1) ST STEEL CARRIAGE BOLT PER CONNECTION. EACH BRACKET SHALL BE FASTENED TO ROOF TRUSS WITH (1) 1' DIA. A276 STAINLESS STEELLAGBOLT. SEE SCHEDULE FOR LAG BOLT DESIGN EMBEDMENT. 5. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITYOFTHECONTRACTORTOPILOTFILLALLHOLES. 6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO SOLENE INSTALLATION MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SOLAR SPECS. 7. ALL LAG BOLTS THIS SHEET SHALL BE A276 STAINLESS STEEL UNLESS OTHERWISE SPECIFIED. 8. SOLENE COLLECTOR(S) THIS SHEET SHALL BE ALL SOLENE AURORA AND SLSG (SPLIT GLASS) COLLECTORS. 9. PVC PIPE RISER/SPACER IS REQUIRED FOR PIPE CLAMPS WHERE PIPE ELEVATION VARIES. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014FLORIDABUILDINGCODF /STH Fmm Ni no i nrni r_n n ouTur rnnr ULTIMATE WIND V- WIND V.e WIND Vie WIND QUANTITY OF EMBED. SPEE PRESSURES PRESSURES PRESSURES BOLTS -BRACKETS DEPTH COLLECTOR V"L (MPH) ZONE 1(PSF) ZONE 2 (PSF) ZONE 3* (PSF PER COLLECTOR REQ. LAYOUT 110-140 17.5 , -27.9 17.5 , -48.6 17.5 , -71.8* 4) e" DIA. (4) BRCK. 2" ** PORT., LAND. 141-175 26.8 , -42.7 26.8 , -74.3 26.8 , -109.9 4) e' DIA. (4) BRCK. 3" ** PORT., LAND. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, RESPECTIVELY. SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND SPEED PRESSURES WITH EXPOSURE "C", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES' AND 2014 F.R.C. MINIMUM Vxd WIND PRESSURE SHALL BE 16.0 PSF AND -16.0 PSF PER ASCE 7-10 SECTION 30.2.2. EFFECTIVE DESIGN WIND AREA IS 10 SF PER COLLECTOR. LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDING ANY ROOF DECKING. UL ,w vviiru cvnr i ANU Z. WIND LUNE 3 INSTALLATION REQUIRES SITE SPECIFIC STRUCTURAL ENGINEER'S APPROVAL TYPICAL COLLECTOR PITCHED ROOF -LAYOUT WIND ZONES - SCHEDULE - PLAN SCALE: NONE SL-3 NOTE: FOR TILE ROOFS, SOLENE MOUNTING BRACKET WITH LIFT KIT ASSEMBLY SHALL BE USED.- ROOF DECKING NOT SHOWN FOR CLARITY. REFER TO SCHEDULE FOR REQUIRED COLLECTOR LAYOUT FOR EACH WIND SPEED. SOLENE ALUM. MOUNTING BRCK. TYP 4 PLCS. SEE SCHEDULE THIS SHEET 2'-0" O.C. TYP. I I I PORTRAIT ORIENTATION TYPICAL COLLECTOR ORIENTATIONS SCALE 1-u ROOF SHINGLES TYP SOLENE ALUMINUM MOUNTING BRACKET. 2 S.Y.P. WOOD ROOF TRUSS BEYOND e" DIA. ST STL LAG BOLT TYP. SEE SCH FOR EMBED DEPTH REQ TYP. WOOD SHEATHING TYP. REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL TYPICAL ASPHALT/METAL SHINGLE CONNECTION DETAIL 3 SCALE: 1 `=V-0" SL-3 SOLENE ALUM. MOUNT BRCK. TYP 4 PLCS. SEE SCHEDULE THIS SHEET I I ILn ILn I I I j j j j j j j I j IN j= JjP5IN a LU aWIC I I DIW W. LL 0 7 0W,0 Wjo WjQ LANDSCAPE ORIENTATION ROOF SHINGLES TYP. SOLENE ALUMINUM MOUNTING BRACKET. SOLENE SOLENE ALUMINUM FRAME SECTION TYP. 16" STAINLESS STEEL CARRIAGE BOLT TYP. PER MOUNT BRACKET SOLENE ALUMINUM FLUSH MOUNT BRACKET SLOTTED HOLE TYP. IN FRAME TYP. TYPICAL CARRIAGE BOLT - FLUSH MOUNT BRACKET CONNECTION DETAIL SCALE: 1 2 REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL CUT OUT OR REMOVE TILE TO INSTALL "LIFT KIT" ASSEMBLY. RE INSTALL, RE -FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF MAT. SOLENE COLLECTOR TYP. SOLENE ALUMINUM MOUNTING , 0 ° BRACKET. ° -" 0 `'. g-" DIA. ST STL LAG BOLT TYP. °o ° SEE SCH FOR EMBED DEPTH REQ TYP. SOLENE 3X3X8 - 4" ALUM. 6063T6 W/ 1" DIA. X 16 - FLAT OR INSERT "LIFT KIT" — BARREL ASSEMBLY TYP. — WOOD TILE TYP. SHEATHING TYP. 2 S.Y.P. WOOD ROOF TRUSS TYP. TYPICAL FLAT TILE - BARREL 2 TILE ROOF CONNECTION DETAIL 6 L-3 SCALE:121"=1'-o" SL-3 ROOF SHINGLES TYP. 1 6- 7 1 1` WOOD SHEATHING TYP. SOLENE ALUMINUM SOLENE COLLECTOR MOUNTING TYP. ° Q; spmFo zo 2 S.Y.P. WOOD ROOF TRUSS TYP. 2X PT S.Y.P. WOOD OR WOOD SHEATHING ALUMINUM UNISTRUT Yp CONT. ALONG PANEL k. ST STL ALL-THRD ROD WITH NUT - wHZ)HERS MAX. 3'-0" O.C.-LOCTITE ALL NUTS TYP. ALL CONNECTIONS TYPICAL LIMITED SPACE OPTION CONNECTION DETAIL 4 SCALE: SL-3 0O+ Ln O^i N f•M Ln Ln Ln . wM00d N af LJL o.-o w M w ce rn ceWV- U Z z Nw C7 n N W w v a: o 0 a w I PROJECT: c=n o w uz aQ z U uj0- ce Mz U) O u Ff N71 LL_ O U) w ry Ln Z J Illy O ¢ m n I Z Q R 15 JAT EEC 2 S.Y.P. WOOD ROOF SCALE: AS NOTED TRUSS BEYOND S.Y.P. (2) 2X4 LOCATE BETWEEN DRAWING # l,J TRUSSES WITH 4-16D NAIL PATTERN p AT EACH END TO WOOD TRUSS R% 8" DIA. ST STL LAG BOLT TYP. SEE SCH RO 111 EMBED DEPTH REQ TYP. l • • SHEET•• rI= rc..•. REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL TYPICAL WOOD SPANNER OPTION SFORUNALIGNEDTRUSS - BRACKET M CONNECTION DETAIL , , • ..RI,"• N SCALE: 1 g =1-0 SL- jvvf !+,/• 3 7 2016 RECORD COPY r i 17 FLORIDA SC)LARENERGY ,ENTER° Approved Solar Energy System FSEC 500170B Approval Date: FEB 2010 DISTRIBUTOR SYSTEM Solene Solene/Aurora 40DC 950 Sunshine Lane Altamonte Springs, Florida 32714 This system was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida Standards Program for Solar Domestic Water and Pool Heating Systems (FSEC Standard 104-05) and was found to meet the minimum standards established by FSEC. North Central South The calculated Florida Energy Factors for this systern are: 3.2 3.5 3.5 DESCRIPTION Collector Manufacturer Model Number Units Total Rating Btu 1. Solene Solene/Aurora SLAR-40 1 37,900 i o tic 2. 3. SANFpRD 4. oFAgR Tank Manufacturer Model Number Capacity (gal) Type: Direct 1. Lochinvar FTA-082K 80 ' 2. Rheem 81RV80-1 80 # 6 - 7 1 13. AO Smith Sun 80 80 4. Any Equivalent UL listed Tank 80 Pump Manufacturer Model Number Power Draw (Watts) Rated Power 1. TACO 006BC4 75 1 /40 H.P. 2. March 809-BR 30 1/100 H.P. 3. Grundfos U P 1518 85 1 /25 H.P. 4. Wilo Star 8 50 1/25 H.P. Controller Manufacturer Model Number Type: Differential controller 1. Goldline GL-30 2. Goldline GL-30LCO 3. STECA TR0301 U Freeze Protection • Freeze prevention valve SANFORD BUILDING DIVISION2. Manual drain down Other Major Components BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS I. T 2 REVIEWED FOR CODE COMPLIANCE ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER ! PLANS EXAMINER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE DATE lo7`."t';!-;!;i;tirR,+.0t;•,„f,1=!r,rns; 31:1';-i7t!3 •'i!: {I-t;i;"s-It.`iV • F=,;i i l•63R•IOF`•;...,i rc.ucEc"iu UN:•; AiY jY;Tff:l:f fLOf ill, • ilvfGu+a CXY;:G" .iFltt un!r.t A iYMJ E':xk::ri . A Hr A.W'l, IV*nurr tK --w LJnr,tk in of Cr NI" F4; Iryi RC RIDA SOLAR ENERGY CENTER'- Approved Solar Energy System FSEC ft SOO I 70B Approval Date: FEB 2010 1(179 R- 12922,570 1 -'11, 32 1 -o A'e 421,6 1 '1' 1 (I A 1,i 't.w-i —f Uvnz m i CrNFRN Ft,01-11 Solaraide'Storage Tank and eedrIc Storage Water Heaters•fbr solar Applications irr i c h SIVRI20-T 0 Available in 80 and 120 Gallon Side Connect and Top Connect Models 6-Year i.bftd Tank and Parts Warranty` Brass drain valve Choice of two models... storage tank or single element water heater, both speciallyequippedforinstallationwithresidential direct solar systems Patented R-Foam insulation process Special threaded stud located near the outlet for attachment of tank sensors Temperature and pressure relief valve Included Collector feed and return fittings located at front of tank for convenient installation Isolated taft-design for better heat retention High efficiency heating element Rh as• tank lining resists corrosion andprolongs tank life units furtYshed standard 240 Will AC. Units are shipped with a 45W watt element Of heating eNments of dffkr- ent wattages than am" shown are demanded by zone requirements, they must be spedfieafly requested. Sofaraide modest meat all curmtt Mquirtments for solar storage tankt. The tanks are Rheertgias tined and are designed to operate up b 150 PSI. These units are designed to meet or exceed ANSI American National Standards Institute) requirements and have been tested according to D.O.E.fastProcedures and meet or exceed line energy effi- ciency requirements of NAECA, ASHRAE standard 90. BOCA Code and all state energy eff. dency peffomlanoe Criteria for energy Consuming appfeances. Before purchasing this appliance, read important energy Cost and stridency information and from your retailer. soon w 62 Cold water inlet brings cold water to tank bottom to prevent mixing with heated water Anode rod equalizes aggressive water action for prolonged tank life Cold water inlet, hot water outlet, relief valve and anode rod at top of tank for easy access and fast, economical installation Automatic temperature control Over temperature protector See Residential Warranty Information Brochure For comaplete warranty information. coCosbDnee n aEAh". ,. q E qv1 art O.O.E rnafnmr mng. ru.i"rate - - artNlavN. 28-1/4 1 336 1 R-16.7 1 28-114 1 336 1 R-16 7 SIDE COFtNECT TOP CONNECTRahtd7" fiaaf e+e bottom. the A special F1u+eaded stud is also helps b the solar a and panel Wnlldad b the tank behind the , helps prevat some arid sediment fnurl ertakg and lower nth opening. tow voltaged.-C- g au Z tt1e solar sensor eAre is run *om 0* Point lntide Ina Jacket and out the top A special threaded stud is also welded totiro tank rker for easy Controlconnectk tin. autlst Ibr attachment Is tank sensors. AfIl ALL 1R CQ%Wcnom Mir"." 1_ © M1lN'Ml.r. f — cowDIUM SIDE CONNECT oouresoa sat was¢aoo ssasoaena Mor avrurr cons me" toe rar oreMwo ocrxscroa ` , mr9Da Aye s Orenma WATfa 001 05CU11r Les aa'IYM 144 uur r 11 saraear=AND aWvanoemge j TOP CONNECT Rheem Water Heaters • 101 Beg Road, Montgomery, Alabama 36117 PRINTED IN U.S.A 09102 WP FORM NO 101.1 Rev. if Steca T•R . 03.01 .1J bigital:accuracy LCD provides real titfie operofi4g 4rRp pratures'at up to three locations 105nimate4 i epr seritat10h o f sAy.! petafan t+.: Sophisticated'.inonitoririg anti :fatllfCliagnostics Fused output,protecfion for•pgrr p-Circuit Varistor high voltage spike..prote" ibn RTD.type •1.000 Q sensors" Adjustable •high,4imit temperature of,storage tank Evacuated tube•&freeze"reds' ui, 64ii -6ictions Vacation overheat protection Accessible side -mounted on, off, auto switch Three temperature sensor inputs', one 120 VAC output Pump protection activated when collector reached 266 OF Display tO rerep--semorsymbals Dfsplaysihe tNPW4%JM wkMs and fai ft e. g. short dnak kftmq . t m or SYS - system enor Anti.fW"hmtsbn SdKIft the temperature uMtf f'C rube caeectof fUnabn Q) SMOng the maAmum storage unk anapest"! Qj SOW amat symboh Q! -04Ts message'Madmm svorage tank Kdperatare has bean reached" t=a dr w x r dts occur. e. g heerruptlan or M - system error Dnokm message far erapoadon of x,e calector fwid Drsolays message for VAdent heat wooly CE Spezialized for the USA Made in Germany Steca is JS09001 " and-1s014001 " certified and registered Steca GmbH Mammostrasse 1 D-87700 Memmingen Germany Tel.: +49(OM33185580 Fax.: +49(0)83318SS812 www.stecasolar.com Steca TR 0301 U The Steca model TR 0301 U differential temperature control provides automatic, safe and reliable operation of domestic solar water heating systems. The TR 0301 U output is wired to a pump that circulates the heat transfer fluid between the solar thermal collectors and the storage tank during the course of the day. This microprocessor -based TR 0301 U utilizes two RTO (resistance temperature detector) type sensors to mo- nitor collector and tank temperatures with digital accuracy. The LCO gi- ves the homeowner a variety of real time information including system temperatures at up to ree separate locations. The consistent use of simple pictograms erlsu ease of operation and troubleshooting. In addition to the prim function of turning the circulating pump on and off during the day, a TR 0301 U provides important diagnostic and safety functions. For exa pie, the LCD pictograms will indicate fault con- ditions such as sensor rts or pump failures..The installation manual also clearly describes the fault symptoms, possible causes and remedies. The TR 0301 U features a total of three inputs for recording tempe- rature and one 120 VAC output for the circulating pump. Varistors protect the sensor inputs against high voltage spikes. The load side is fuse protected. The control package includes two RTD type sensors, a seven foot line cord and a spare fuse. An optional third sensor displays the upper tank temperature and eliminates the need for an analog thermometer and fittings. The numerous additional features of the TR 0301 U include an adju- stable high limit (32" F - 205' F), an evacuated tube collector function, vacation overheat protection to minimize collector stagnation, and a freeze -recirculation option. Temperatures can be displayed in either Fahrenheit (°F) or Celsius (QC). Technical • • • Operating voltage 120 VAC, 60 Hz optional 240 VAC 60 Hz) Self consumption s 0.001 HP 3 inputs for temperature Pt1000 recording 1 output Switch relay; Switching performance max 0.5 HP (120 V—); 1 HP (240 V—) Fuse protected Fuse: Littelfuse 215.004 Dine cord 7', 18 AWG raced at 221 'F Display Animated LCD display, 2-color round Protection class IP 20/DIN 40050 Permitted ambient temperature 32 to +113 °F (0 to +45 'C) Installation Wall -mounted with screws Weight 19.54 oz 0.55 k ) include cable Case Recyclable 3-piece plastic case Dimensions 6.3"(W) x 6.18"(11) x 1.85"(D) 160 L x 157 8 x 47 H mm) Temperature sensors 2x Pt1000 Collector sensor, 59 inch (1.5 m) silicone cable with bushing Measuring range up to +356IF (+ 180'C)) Storage tank sensor. 11.8 inch (0.3 ni) twisted single conductor fiat surface sensors with compression cable lug Measuring range up to 222'F (+105'C)) Dimensions System setup W. 4 optianaQ Single storage solar system Siarxlan:l- without connection cable Put temperature sensor Aput power connection jq-r pump rgvut not occupied sins connection cable mp socket Prefabricated,' with mains connection cable and pump socket Storage tank sensor Pt1000-Lu 4 Temperature010sensorincluded Collectorsensor, Ptr000,Probe tcra GmhH • Mammostrasse 1 - D-87700 Memminoen • Germanv • Fon: +49 (0)8331 8558 0 • Fax: +49 (0)8331 8558 12 • www.stecasolar.com a Wet -Rotor, In -Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR SUBMITTED BY: APPROVED BY: RDERNO: ICATION NO: 1rtODFt N Technical Data FLOW RANGE: 0 to 17 U.S. GPM HEAD RANGE: 0 to 16 Feet MOTORS: 2 Pole, Single Phase MAXIMUM FLUID TEMPERATURE: 150-F (WC), Maximum design temperature. MIN. FLUID TEMPERATURE fkw UPfS: 36•F (2-C) TIMER: 24 hours 3 p031110ns (ON/TIMER/OFF) 15 minute Interval. LINE CORD. Six -Foot I" with 5-15P grounded plug. MAXIMUM WORKING PRESSURE; 145 PSI MINIMUM REQUIRED INLET PRESSURE: At 150-F (86•C), 3.0 FL (0.9m) 1.3 PSI. 0 Dimensions, and Weights UP15-is-P18B585 i 10a 1377. 8 UUP15-IOSUCS UPI542B5a87 U315.18SU UP15.10BUC7 A i C D, F O UP15- 1085/ LC TLC 5 63/m 5'/2 4 UP15-1087/ LC a TLC 63l4 62/s 5'/z 3T3/N UP15-1885/ LC a TLC 5 63/rs 51/2 31/z UP15 1887/ LC a TLC 63/4 51/2 3t310 UP15-4285/ 1-C b TLC 5 63/w 5'/2 3'/2 UP154287/LC d TLC 63/2 UP15-10BUC5/ LC a TLC 6'!z 6 3/4 5'/z 3 Vi. UP15-tOBUC7/ LC a TLC 73/. 63/. 5 UP15-18SU/ LC 6 TLC NOTES — d" rmensions are in inches. DATE: DATE: DATE: Tlme. a une cord Z le C Shipping 3'/2 WL Lbs. Sweat -'!i 6.5 4 3114 4 Sweat - 3/: 7.2 31/4 4 Sweat -'/2" 8.5 3'/4 4 Sweat - 3/4" 72 31/4 4 Sweat -'/2• 6.5 3'/ 4 Sweat - 31; 72 3'/4 1 4 Sweat 112 7.7 3'/4 4 Sweat 3/: 8.5 Union - 1'/: NPSM 55 11 Performance stainless steel or &Onze Cons&ucton _ Flarve, union, or swear Mount S. upl"asu 8- UP1542B5 Note: Performance No c,Rv7VENOo7t1[to7[[[[[ IN Electrical Data MODEL' VOLTS AMPSKWATTS CAPACITORF42UP1b10B53B711555 SµF1180VUP1SAMB511574 10µFl180VUP15-1887 115 74 10µF/18DV Materials of Construction VOLTS AMPS . WATTS HP CAPACITOR 115 .74 85 r 10 F/180V 115 .74 85 Ya lopFl180V 5/7 115 0.55 60 1/25 8uF1180V MATERIAL IMet Cane. Bearing Plate. Bearing Retainers. %tor Can. Rotor Gadding. Shaft Retainer. 304 Stainless Steel ORing 3 Caskets MATERIAL Pump Hasstng (Volute) on EP (Ethylene Propylene UP15 18S1U5F Pump Housing (Vdute) for UP 15-1085 Q B7, SBkxme Bronze C875UPtS-18B5 3 87, UP15-42856 87, Vdute Retainer(SU MOdel) 6 Stabr HorsingUP15 108t105687 gyp• PES Composite (30'K Shaft, Upper 6 Lower RadialBeadnasAtunwaan Oxide Ceramic B°a McQellmpre9natedCarbon TennkulSox Claa— 1) os•V- q=FZUN"1= Grundfus rumps Corporation • 17100 W. lWth Terrace • Olathe. K5 66061 hone: 913. 2273400 • Fax. 913 2273500 Canada: Oakville. Onta00 - Mexice: Apodaca, N L WIX Owwehsfde Ot www.grvndfos wm 1rP- 3A Rev.BTli PRINTED MJ I15A MINIM "'I" TECHNICAL INFORMATI NAJA'I pl'1 AURORA Solar Collectors by SoleneTM ANDAJWRUM TECHNOLOGICALLY ADVANCED SOLAR COILECTQRS BY SOLENE'R ENGINEERING FOR MAXIMUM PERFORMANCE AURORA Solar Collectors are the most technologically advanced collectors on the market today. AURORA featuresthehighestqualitymaterials & state-of-the-art engineering to provide maximum efficiency & durability you candependonforyearstocome. AURORA collectors are envirnr,mantnIN, and reliable in or important compo producing depern weather conditior 8 4 S K 1- Absorber Plate Utilizing a state-of-the-art sonic weld, copper fins and risers provide superior thermal connectivity between the fins and risers. Revolutionary coating is black chrome on nickel, producing a premium selective surface with maximum efficiencyforsolarenergyuse. Easy absorber replacement if needed. Absorbability = 0.95 Emissivity = 0.12 7. Tubing Grid 3/8" copper risers are brazed to 1 " copper mainfolds for optimal flow distribution. 3. Piping Connection 1 " Type M copper header. 6 7 1 9 5 and around the side of the absorber plate, retains the heat of the water in the collector. DFC-free P.U. meets U.S. and European standards. A 3/4" layer of mineral wool protects the polyurethane and provides additional collector insulation, e. Casing All aluminum extrusion casings create asleekfromewall. Unique extruded profile allows easy anchoring to the roof (shingle, tile, tar) or collector stands. Reinforced corner assemblies to increase rigidity. 9. Gaskets All-around EPDM gasket. Highly resistant to' temperature differences and Uv radiation. 7. Insulation Absorbs the differential expansion of frame1-3/16" polyisocyanurate foam cast under and glazing, 4. Aluminum Foil Attached to the insulation, acts as a barrier against out-gasing. 5. Solar Glass Glazing A single pane of 1/8" thick solar glass is patterned to reduce reflection and tempered to maximize strength and durability. Iron oxide content: 0.03% Solar transmittance: 91 % 6, Back Plate High -Density Polyethylene Backing, - Reduces torque in the frame, is lightweight and eliminates the possibility of any electrolysis issues for maximum benefit. SC7 L.f1L°,' The best investment der the sun! OLARHOTWATERSYSTEMSunder rruFL: Via; r TTr AURORA Solar Collectors by SoleneT"' SPECIFICATIONS AND EFFICIENCIES Models General Specifications AURUAn"'RA SOLAR COLLECTORS BY SOLENET" Gross Area (sq. ft.) - 31.78 40.38 Net Aperture Area (sq. ft.) 30.53 37.44 Ratio Net/Gross Area 0.95 0.95 Length (in.) 96.48" 1 17.96" Width (in.) 47.4" 47.4" Thickness (in.) 3.96" 3.96" Weight (lbs.) 105.8 132.2 Fluid Capacity (gal.) 1.05 1.2 Recommended Flow Rate 0.6 0.7 Test Pressure (psi) 300 300 Operating Pressure (psi) 145 145 Efficiency Ratings Clear Day Mildly Cloudy Cloudy Day Clear Day Mildly Cloudy Cloudy Day A (-9° F) 46.1 34.8 23.7 56.5 42.7 29.0B (9° F) 41.3 30.1 18.9 50.7 36.9 23.2C (36° F) 34.5 23.5 12.6 42.4 28.8 15.4D (90° F 22.4 12.4 3.3 27.6 15.3 4.1E (144- F) 12.0 4.1 0.0 14.9 5.1 0.0 Efficiency Equation [NOTE: Based on grois area and (P)=Ti-Taj] S I UNITS: r1=0.7820-4.28290 (P)/I-0.00484 (P)2/1 1 P UNITS: r1=0.7820-0.7544 (P)/I-0.0005 (P)2/1 Y INTERCEPT SLOPE 0.8 -4.6 W/m2.° C 0.8 -0.8 Btu/hr.42.' F Efficiency Equation [NOTE: Based on gross area and (P)=Ti-TailSIUNITS: r1=0.7840-4.28050 (P)/I .0.00484 (P)2/1 I P UNITS; ,q=0.7840-0.7540 (P)/I-0.0005 (P)2/1 Y INTERCEPT SLOPE 0.8 -4.6 W/m2., C 0.8 -0.8 Btu/hr.ft2.0 F Ti = Water temperature IT out - T in)/2 F FSECTo = Ambient temperature F 1= Solar radiation Btu/hr/ft2 OG-100 Collector Approved lene OG- 300 System Approvals Made In USA S'P.imorWATER SYSTEMS Solene Corporate Headquarters: 950 Sunshine Lane Altamonte Springs, FL 32714 Toll Free 1-800-506-1994 Distribution Centers: Orlando, FL • Philadelphia, PA • Fairfield, CA Uplift Force on Collector Connection Fc°nn•ni°n = [(Uplift -Collector Weight)/(Quantity of Connection Points)]*Effective Area -Neglect Collector WeightTotalWindArea (sf) Quantity of Connection Points per Collector 40 Uplift Force per Collector Connection (Ibs/connection) _ — - 4 _ 743 ' Required Lag Bolt Size and Length to Wood Truss Per Latest Edition ASD NDS for Wood Construction W' = W*(Cd)*(CmMC( ) Southern Pine Wood Truss Specific Gravity - G Withdraw Value for 8" Leg Bolt (Ibs/in) and specified Specific 0.55 Gravity = 352 Embedment Depth (in) Embedment Withdraw Design Value - W (Ibs) __ 3 t Load Duration Factor (Cd) for Wind Load (Ten Minute intervals) 1056 Wet Service Factor (Cm) in areas > 19% mQ:tur2 content in-service 1.6 conditions = 0.7 Temperature Factor (C,) in areas with experience sustained exposured to 212vated tProperatur2s l °F < T< 150 °F = 0.7 Adjusted Embedment Withdraw Design Value - W' (Ibs) _ Acce table Design Value Check 827.9 Note: These calculations are applicable for the generic drawings labeled as SL-3C. Threaded embedment depth above excludes any roof decking. Rick Castillo, PE FL PE #52590 - COA1,728345 ow s CAST/44 jfo. r "• • p 0.5 n •• F rtd. ST EO e " b F_ 1 00. 0 • •••• to i7\ 4111 t* 41111111 0% tz/ 11/5 1. APPLICABLE CODE: 2014 FLORIDA BUILDING CODE (5TH EDITION) & ASCE-7-1 MMINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE 5TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27 " (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. BUILDING NOT TO EXCEED 30'-0" ROOF HEIGHT. CONTRACTOR RESPONSIBLE TO VERIFY ROOF SLOPE. 4.EACH BRACKET SHALL BE FASTENED TO THE COLLECTOR WITH (1) ST STEEL CARRIAGE BOLT PER CONNECTION. EACH BRACKET SHALL BE FASTENED TO ROOF TRUSS WITH (1) 8" DIA. A276 STAINLESS STEELLAGBOLT. SEE SCHEDULE FOR LAG BOLT DESIGN EMBEDMENT. 5. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO SOLENE INSTALLATION MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SOLAR SPECS. 7. ALL LAG BOLTS THIS SHEET SHALL BE A276 STAINLESS STEEL UNLESS OTHERWISE SPECIFIED. 8. SOLENE COLLECTOR(S) THIS SHEET SHALL BE ALL SOLENE AURORA AND SLSG (SPLIT GLASS) COLLECTORS. 9. PVC PIPE RISER/SPACER IS REQUIRED FOR PIPE CLAMPS WHERE PIPE ELEVATION VARIES. in MNTPAr-rnP CNAI I FAICI IDC AI I Dnnc n—i—.T FLORIDA BUILDING CODE (5TH EDITION) OR LOCAL GOVERNING CODE V Jam" r`n cvi r ULTIMATE V d WIND Vie WIND V, WIND QUANTTfI OF EMBED. COLLECTORWINDSPEECPRESSURESPRESSURESPRESSURESBOLTS - BRACKETS DEPTH V"c (MPH) ZONE 1(PSF) ZONE 2 (PSF) ZONE 3* (PSF) PER COLLECTOR REQ. LAYOUT 110-140 17.5 , -27.9 17.5 , 48.6 17.5 , -71.8* 4) 8• DIA. - (4) BRCK. 2" ** PORT., LAND. 141-175 26.8 , -42.7 26.8 , -74.3 26.8 , -109.9 4) 8" DIA. - (4) BRCK. 3" ** PORT., LAND. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, RESPECTIVELY. SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND SPEED PRESSURES WITH EXPOSURE "C", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2014 F.R.C. MINIMUM Vaa WIND PRESSURE SHALL BE 16.0 PSF AND -16.0 PSF PER ASCE 7-10 SECTION 30.2.2. EFFECTIVE DESIGN WIND AREA IS 10 SF PER COLLECTOR. LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDING ANY ROOF DECKING. INSTALLATION OF COLLECTORS MUST BE IN WIND ZONE 1 AND 2. WIND ZONE 3 INSTALLATION REQUIRES SITE SPECIFIC STRUCTURAL ENGINEER'S APPROVAL. TYPICAL COLLECTOR PITCHED ROOF LAYOUT WIND ZONES - SCHEDULE - PLAN 1 SCALE: SL-3 NOTE: FOR TILE ROOFS, SOLENE MOUNTING BRACKET WITH LIFT KIT ASSEMBLY SHALL BE USED. ROOF DECKING NOT SHOWN FOR CLARITY. REFEk TO SCHEDULE FOR REQUIRED COLLECTOR LAYOUT FOR EACH WIND SPEED. Ala d jo oj!LLYLn W O W V d' SOLENE ALUM. MOUNTING BRCK. TYP 4 PLCS. SEE SCHEDULE THIS SHEET 2'- O" O.C. TYP. T-O" O.C. TYP. Dr I- o LL Lu. Lu.I WO w,0 WIO PORTRAIT ORIENTATION TYPICAL COLLECTOR ORIENTATIONS SCALE: 1--U.. ROOF SHINGLES TYP. SOLENE ALUMINUM MOUNTING BRACKET. SOLENE — COLLECTOR TYP, - 2 S.Y.P. WOOD ROOF TRUSS BEYOND 8" DIA. ST STL LAG BOLT TYP. SEE SCH FOR EMBED DEPTH REQ TYP. WOOD SHEATHING TYP. REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL TYPICAL ASPHALT/METAL SHINGLE CONNECTION DETAIL 3 SCALE: 1 i"=V-0" SL-3 SOLENE ALUM. MOUNT BRCK. TYP 4 PLCS. SEE SCHEDULE THIS SHEET I I I I I I I I of I( if 1= I Lu En ILL LnI LL LuKKcgOw0 LANDSCAPE ORIENTATION ROOF SHINGLES TYP. SOLENE ALUMINUM MOUNTING BRACKET. SOLENE SOLENE ALUMINUM FRAME SECTION TYP, 16" STAINLESS STEEL CARRIAGE BOLT TYP. PER MOUNT BRACKET SOLENE ALUMINUM FLUSH MOUNT BRACKET SLOTTED HOLE TYP. IN FRAME TYP. TYPICAL CARRIAGE BOLT - FLUSH MOUNT BRACKET CONNECTION DETAIL SCALE: 1 i"=V-0" REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED " X" IN THIS DETAIL CUT OUT OR REMOVE TILE TO INSTALL "LIFT KIT' ASSEMBLY. RE -INSTALL, RE - FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF MAT. SOLENE COLLECTOR TYP. SOLENE ALUMINUM MOUNTING ° ° BRACKET. ° a" DIA. ST STL LAG BOLT TYP. SEE SCH FOR EMBED DEPTH REQ TYP. SOLENE 3X3X6 - 4" ALUM. 6063T6 W/ 1" DIA. X 16 FLAT OR INSERT " LIFT KIT' BARREL ASSEMBLY TYP. WOOD TILE TYP SHEATHING TYP. 2 S.Y.P. WOOD ROOF TRUSS TYP. TYPICAL FLAT TILE - BARREL TILE ROOF CONNECTION DETAIL 6 SCALE: 121"=1'-0" SL-3 SOLENE ALUMINUM MOUNTING BRACKE- 2 S.Y.P. WOOD ROOF TRUSS TYP. 2X PT S.Y.P. WOOD OR ALUMINUM UNISTRUT 3 TYP. CUNT. ALONG PANEL s DIA. ST STL ALL-THRD ROD WITH NUT - WASHERS MAX. T-0" O.C.-LOCTITE ALL NUTS TYP. ALL CONNECTIONS TYPICAL LIMITED SPACE OPTION CONNECTION DETAIL 4 SCALE: 12"=V-0" SL-3 ROOF SHINGLES TYP. WOOD SHEATHING TYP. SOLENE COLLECTOR 2 S.Y.P. WOOD ROOF TRUSS BEYOND S. Y.P. (2) 2X4 LOCATE BETWEEN TRUSSES WITH 4-16D NAIL PATTERN AT EACH END TO WOOD TRUSS TYP. 8" DIA. ST STL LAG BOLT TYP. SEE SCH FOR %1 EMBED DEPTH REQ TYP. REFER TO SCHEDULE THIS SHEET FOR REQUIRED ~ EMBEDMENT DEPTH IABELED "X" IN THIS DETAIL E TYPICAL WOOD SPANNER OPTION FOR UNALIGNED TRUSS - BRACKET -o CONNECTION DETAIL - , '- SCALE: 1 z"=1'-0" SL4 _'S 0 rnr1l Ln ON CN fM Ln M co d NMI LJL Oo=. r0 U V-u^ J w N u C', (QQn c7 o = z a coc0,1 n rn02 Ow cy w V U Z z z, ;!:ntw 00 C7 n N Lu w rez O a w PROJECT: Lu J Jcn Lu w oz a ¢ z U L Z oo x0- W J Ln N o F LL_ o Gi w r w z wwLLJ oo 1` s JAI FASNOTED DRAWING # CCII C e RzSOf P C MENO • oWIT12 T Q •: R. w- Z Willatv"2916