Application No:
Documented Construction Value: $ 3,157.51
Job Address: 1101 Pine Ave., Sanford, FL 32771
Parcel ID: 25-19-30-5AG-130C-0000
Historic District: Yes ❑ No ❑■
Residential ❑ Commercial ■❑
Type of Work: New X Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑
Description of Work: Replacing existing FACP with same. Reconnect existing devices and
connect new devices to FACP. Working under building permit #16-1697.
Plan Review Contact Person: Nicole Sealy
Phone: 407-637-8396 Fax:
Title: Permit Tech
Email: engineering@dynafire.com
Property Owner Information
Name Community Improvement Assn of Seminole County Inc. Phone:
Street: 1590 Rochelle Lane
City, State Gip: Oviedo, FL 32765
Name DynaFire, Inc.
Street: 109B Concord Dr.
Resident of property0 O
�,
Contractor Information
City, State Gip: Casselberry, FL 32707
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Phone: 407-830-6500
Fax:
State License No.: EF20000528
Architect/Engineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5'^ Edition (2014) Florida Building Code
Revised: June 30. 2015 Permit Application
DATE: 713117
BUSINESS/PROJECT NAME:
//
ADDRESS: o/ X
CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION
FIRE PLAN REVIEW SERVICE FEES
PHONE: 407.688.5052
FAX: 407.688.5051
PERMIT NUMBER:
CONTACT NAME: PHONE:
PLAN REVIEW INFORMATION
[) CONSTRUCTION [ ]C/O FIRE ALARM [ ] FIRE SPRINKLER [ ] HOOD
DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES ( 3N
TOTAL FEES: '7j-, aU
[ )PAINT BOOTH [ )TANK
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning. _
Signature ot'Otirner/Agent Date Signa
Print Owner/Agent's Name
Signature of Notary -State of Flonda Date
Owner/Agent is Personally Known to Me or
Produced ID Type of ID
Print Co ractor/A ent's Name
Kk6die o
KRISTYN S. WELCH
�.qy P 0•
` �%•- Notary Public •Stale o1 Florida
c;
• = Commission # GG058981
;�• "� M Comm. 'plies Jan 9. 2021
Y
OF " Bonded th 0 National Notary Assn.
Co r nally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[-] Gas[] Roof ❑
Construction Type:
Total Sq Ft of Bldg:
Occupancy Use:
Min. Occupancy Load:
Flood Zone:
# of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures,
Fire Sprinkler Permit: Yes No ❑ # of Heads
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
Fire Alarm Permit: Yes ❑ No ❑
UTILITIES: WASTE WATER:
FIR 7/ BUILDING: ?- • /?
Revised June 30.2015 Pennit Application
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
D 1
Application No: l I -' 0 Q -I
Documented Construction Value: $ 4,300
Job Address: 1101 Pine Avenue Historic District: Yes K No ❑
Parcel ID: Residential ❑ Commercial ❑■
Type of Work: New ❑ Addition ❑ Alteration ❑ Repair 9 Demo ❑ Change of Use ❑ Move ❑
Description of Work: Replace Hvac per plans
Plan Review Contact Person: R; r- Title: tu_d,eY
Phone: f-9"�'��' �!6ax: Email: (iie�t��(a�t)� Itt/C, Com
Property Owner Information
Name Community Inprovement Association Phone:
Street: 1101 Pine Avenue Resident of property?: No
City, State Zip: Sanford FL
Contractor Information
Name RirANew-r-A� NlnrrlSsgAtJ Phone: Sir- 922-- y`tra R
Street: b o"La i e,.,< �I" _ Fax:
City, State Zip: i g,tLn 6t/l R?D.d PE( State License No.: CAC 19 18566 9
ArchitecVEngineer Information
Name: CPH, Inc.
Street: 500 West Fulton Street
City, St, Zip: Sanford FL 32771
Bonding Company:
Address:
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of applicationandthe codeineffect as of that date: 5'^ Edition (2014) Florida Building Code
Revised: June 30, 2015 ` _ �� V (,— I Pennit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
Signature of Owner/Agent Date
Print Owner/Agent's Name
Signature of Notary -State of Florida Date
Owner/Agent is Personally Known to Me or
Produced ID Type of ID
Sig4.rnttactor/ ate
Print
Signature aDate
�UBLtC
STATE OF FLORIDA
COMMIt FF979289
Expires 4/4/2020
Contractor/Agent is Personally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas[] Roof ❑
Construction Type: Occupancy Use: Flood Zone: -
Total Sq Ft of Bldg:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes❑ No ❑ # of Heads
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
UTILITIES:
FIRE:
# of Stories:
Plumbing - # of Fixtures
Fire Alarm Permit: Yes ❑ No ❑
WASTE WATER:
BUILDING:
Revised: lune 30, 2015 Permit Application
q
D Yll4AFIRE
OFFICE
109-B Concord Drive
Casselberry, FL 32707
407.830.6500
DynaFire.com
DYNAfilET I
PERMIT
PRODUCT DATA SUBMITTALS
FIRE ALARM SYSTEM
DATE: June 23, 2017
PROJECT: Sanford Community Center
CUSTOMER: City of Sanford
REPRESENTATIVE: Bob Seekamp
PREPARED BY: Miguel A Vargas
Casselberry I Largo I Jacksonville I Pompano I Melbourne
EF20000528 I FL PE26483 I NICET 1V 99907 1 FP 16481600012009 1 FPC15-000057
Wlrolew
Alarm MOnkering
Sanford Community Center
Fire Alarm System Submittal
ITEM
PART #
MANUF.
DESCRIPTION .
Panel Equipment
1
MS-9050UD€
FIRE -LITE
Addressable Fire Alarm Control Panel w/backup batteries
2
7788F-ULP
AES
Wireless Fire Alarm Communicator
w/ back-up batteries
Notification Appliance Devices
2
SRL
Wall Mount strobe - Red @15CD
Wire
1
Notification
Windy City Wire
14 AWG, THHN
Batteries & Calculations
2 Batteries Notifier BAT -1270
MS-905OUD(E)
Fire Alarm Control Panel
with DACT
General
The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel
(FACP) and Digital Alarm Communicatorlfransmitter (DACT)
combined into one circuit board. This compact, intelligent
addressable control panel supports up to 50 addressable
devices of any type of detectors and modules. With an exten-
sive list of powerful features, the MS-9050UD programs just like
Fire-Lite's larger products, yet fits into applications previously
served only by conventional panels.
The MS-9050UD's integral DACT transmits system status
(alarms, troubles, AC loss, etc.) to a Central Station via the pub-
lic switched telephone network. It also allows remote and local
programming of the control panel using the PK -CD Upload/
Download utility. In addition, the control panel may be pro-
grammed or interrogated off -she via the public switched tele-
phone network. Any personal computer with Windows" 95 or
greater, and compatible modem with a speed of 14.4 kbps or
faster and Fire•l-Ke Upload/Download software kit PK -CD, may
serve as a Service Terminal. This allows download of the entire
program or upload of the entire program, history file, walk -test
data, current status and system voltages.
The power supply and all electronics are contained on a single
circuit board supported on a new quick install chassis and
housed in a metal cabinet. Available accessories include local
and remote upload/download software, remote annunciators,
and reverse polarity/ciy, box transmitter. (4XTMF)
New options include a UL listed printer, PRN -6F and the new
IPDACT Internet Monitoring module.The FireWatch Series Inter-
net monitoring modules IPDACT 2 and IPDACT 2UD permit
monitoring of alarm signals over the Internet, saving the monthly
cost of two telephone lines. Although not required, the second-
ary telephone line may be retained providing backup communi-
cation over the public switched telephone line.
NOTE. Unless otherwise specified, the term MS-905OUD is used
in this data sheet to refer to both the MS-905OUD and the MS-
9050UDE FACPs. For MS-9050UDC, refer to DF -60445.
Features
• Listed to UL Standard 864, 9th edition.
• Auto -program (learn mode) reduces installation time.
Reports two devices set to the same address.
• On -board DACT.
• Two independently programmable Style Z (Class A) or Style
Y (Class B) NAC circuits.
• Selectable strobe synchronization for System Sensor, Whee-
lock, and Gentex devices.
• Remote Acknowledge, Silence, Reset and Drill via address-
able monitor modules.
• Two programmable relays and one fixed trouble relay.
• Built-in Programmer.
• Telephone Line Active LEDs.
• EIA -232 PC interface.
• Integral 80 -character LCD display with backlighting.
• Real-time clock/calendar with automatic daylight savings
control.
• History file with 500 event capacity.
• Automatic detector sensitivity testing (NFPA 72 compliant).
• Automatic device type -code verification.
DF -52418:E1 • Al -20
8FIre-LITerAWMS
by Honeywell
• Point trouble identification.
• Waterflow selection per module point.
• Alarm verification selection per detector point.
• Maintenance alert warns when smoke detector dust accumu-
lation is excessive.
• One-person audible or silent walk test with walk -test log and
printout.
• System alarm verification selection per detector point.
• PAS (Positive Alarm Sequence) and Pre -signal per point
(NFPA 72 compliant).
• Up to eight ANN -BUS annunciators
• Remote Acknowledge, Alarm Silence, Reset and Drill via
addressable modules or remote annunciator.
• UploadlDownload (local or remote) of program and data via
integral DACT.
SLC COMMUNICATION LOOP
• Single addressable SLC loop which meets NFPA Style 4, 6
and 7 requirements.
• 50 addressable device capacity (any combination of address-
able detectors and modules).
• Compatible with Fire•Lite's addressable devices (refer to SLC
Wiring Manuak
NOTIFICATION APPLIANCE CIRCUITS (NACS)
• Two independently programmable output circuits. Circuits
can be configured for the following outputs:
— Style Y (Class B)
— Style Z (Class A)
– Door Holder Service (cannot be used for notification appliances)
– Aux Power Source (cannot be used for notification appliances)
• Silence Inhibit and Autosilence timer options.
• Continuous, March Time, Temporal or California code for
main circuit board NACS with two-stage capability.
• Selectable strobe synchronization per NAC.
• 2.5 A total power for NACs.
NOTE. Maximum or total 24VDC system power shared between
all NAC circuits and the ANN -BUS is 2.7 A.
DF-5241e:E1 •1/27/12 — Page 1 of 4
B6 -12U( Addressable
Manual Pull Station
Multi -Modules
• CRF -300.6 Six -Relay Control Module
• CMF -300.6 Six -Circuit Supervised Control Module
• MMF-302-6 Six -Zone Interface Module
• MMF-300-10 Ten -Input Monitor Module
MS-905OUD
ADDRESSABLE FIRE ALARM
CONTROL PANEL
Page 2 of 4 — DF -52416:E1 •1/27/12
PROGRAMMING AND SOFTWARE
• Autoprogram (learn mode) reduces installation time.
• Custom English labels (per point) may be manually entered
or selected from an internal library file.
• Two programmable Form -C relay outputs.
• 20 software zones.
• Continuous fire protection during online programming at the
front panel.
• Program Check automatically catches common errors not
linked to any zone or input point.
• OFFLINE PROGRAMMING: Create the entire program in
your office using a Windows based software package(order
programming kit PK -CD, containing PS -Tools, separately).
Upload/download system programming locally.
User interface
LED INDICATORS
• AC Power (green)
• Fire Alarm (red)
• Supervisory (yellow)
• Trouble (yellow)
• Alarm Silenced signals (yellow)
KEYPAD
• 16 key alpha -numeric pad
• Acknowledge/Step
• Alarm Silenced
• Drill (Manual Evacuate)
• Reset (lamp test)
Product Line Information
MS-9050UD(E): Combination DACT/Fire Alarm Control Panel
with one SLC loop. Includes main circuit board with display,
chassis with transformer, backbox with door, plastic bag contain-
ing screws, cables, key, etc., manual. (For MS-9050UDC, refer
to DF -60445.)
PK -CD: Contains PS -Tools programming software for Win-
dowsQD*based PC computer (cable not included).
DP -51050: Optional dress panel for the MS-9050UD.
TR -CE: Optional trim ring for semi -flush mounting.
BB -2F: Optional cabinet for one or two modules.
BB -6F: Optional cabinet for up to six modules mounted on
CHS -6 chassis.
BB -26: Battery backbox, holds up to two 25 AH batteries and
CHG-75.
BB -55F: Battery box, houses two 55 AH batteries
CHS -6: Chassis, mounts up to six mufti -modules in a BB -6F
cabinet.
CHG-75: Battery charger for lead -acid batteries with a rating of
25 to 75 AH.
CHG-120F: Remote battery charging system for lead -acid bat-
teries with a rating of 55 to 120 AH. Requires additional BB -55F
for mounting.
BAT Series: Batteries, see data sheet DF -52397.
PRT/PK-CABLE: Cable printer/personal computer interface
cable.
PRN -6F: UL listed compatible event printer. Uses tractor -fed
paper.
IPDACT, IPDACT212UD Internet Monitoring Module: Mounts
In bottom of enclosure with optional mounting kit (PN IPBRKT).
Connects to primary and secondary DACT telephone output
ports for internet communications over customer provided ether -
net internet connection. Requires compatible Teldat Visoralarm
Central Station Receiver. Can use DHCP or static IP. (See data
sheet df -52424 for more information.)
IPBRKT. Mounting kit for IPDACT 212UD in common enclosure.
IPSPLT: Y adaptor option allows connection of both panel dialer
outputs to one IPDACT 2/2UD cable input.
AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in
turn, mounts to the FACP chassis. Use AC-TRMBLK when wire
nuts are not allowed for AC connections to the transformer.
OPTIONAL MODULES
4XTMF Reverse Polarity Transmitter Module: Provides a
supervised output for local energy municipal box transmitter,
alarm and trouble. Includes a disable switch and disable trouble
LED.
ANN -SEC: Optional secondary ANN -BUS interface module.
Note: Used only with firmware 3.0 or higher.
COMPATIBLE ANNUNCIATORS
ANN -80(-W): Remote LCD annunciator mimics the information
displayed on the FACP LCD display. Recommended wire type is
un -shielded. (Basic model is red; order -W version for white; see
DF -52417.)
ANN -UO: LED Driver Module provides connections to a user
supplied graphic annunciator. (See DF -52430.)
ANN -LED: Annunciator Module provides three LEDs for each
zone: Alarm, Trouble, and Supervisory. Ships with red enclo-
sure. (See DF -60241.)
ANN -RILED: Provides alarm (red) indicators for up to 30 input
zones or addressable points. (See DF -60241.)
ANN-RLY: Relay Module provides 10 programmable Form -C
relays. Can be mounted inside the cabinet. (See DF -52431.)
ANN-S/PG: Serial/Parallel Printer Gateway module provides a
connection for a serial or parallel printer. (See DF -52429.)
ADDRESSABLE DEVICES
All feature a polling LED and rotary switches for addressing.
CP355: Addressable low -profile ionization smoke detector.
SD355: Addressable low -profile photoelectric smoke detector.
SD355T: Addressable low -profile photoelectric smoke detector
with thermal sensor.
SD355R: Remote test capable addressable photoelectric
smoke detector for use with DNR(W) duct detector housing.
H355: Fast -response, low -profile heat detector.
H355R: Fast -response, low -profile heat detector with rate -of -
rise option.
H355HT: Fast -response, low -profile heat detector that activates
at 190°F/88°C.
AD355: Low -profile, intelligent, "Adapt" multi -sensor detector
(B350LP base included).
BEAM355: Intelligent beam smoke detector.
BEAM355S: Intelligent beam smoke detector with integral sen-
sitivity test.
D355PL: InnovairFlex low -flow non -relay duct -detector housing;
includes SD355R.
DNR: InnovairFlex low -flow non -relay duct -detector housing.
(Order SD355R separately.)
DNRW: InnovairFlex low -flow non -relay duct -detector housing,
with NEMA4 rating. Watertight. (Order SD355R separately.)
MMF-300: Addressable Monitor Module for one zone of nor-
mally -open dry -contact initiating devices. Mounts in standard
4.0' (10.16 cm.) box. Includes plastic cover plate and end -of -line
resistor. Module may be configured for either a Style B (Class B)
or Style D (Class A) IDC.
MDF -300: Dual Monitor Module. Same as MMF-300 except it
provides two Style B (Class B) only IDCs.
MMF-301: Miniature version of MMF-300. Excludes LED and
Style D option. Connects with wire pigtails. May mount in device
backbox.
MMF-302A: Similar to MMF-300A. Addressable Monitor Module
for one zone of conventional two -wire detectors. Requires reset -
table 24 VDC power. Refer to the Device Compatibility Docu-
ment for listed compatible devices and quantity limitation.
CMF -300: Addressable Control Module for one Style Y2 (Class
B/A) zone of supervised polarized Notification Appliances.
Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification
Appliance Circuit option requires external 24 VDC to power noti-
fication appliances.
CRF -300: Addressable relay module containing two isolated
sets of Form -C contacts, which operate as a DPDT switch.
Mounts directly to a 4.0' (10.16 cm.) box, surface mount using
the SMB500.
BG-12LX: Addressable manual pull station with interface mod-
ule mounted inside.
1300: This module isolates the SLC loop from short circuit condi-
tions (required for Style 6 or 7 operation).
SMB500: Used to mount all modules except the MMF-301 and
M301.
MMF-300-10: Ten -input monitor module. Mount one or two mod-
ules in a BB -2F cabinet (optional). Mount up to six modules on a
CHS -6 chassis in a BB -6F cabinet.
MMF-302-6: Six -zone interface module. Mount one or two mod-
ules in a BB -2F cabinet (optional). Mount up to six modules on a
CHS -6 chassis in a BB -6F cabinet.
CMF -300-6: Six -circuit supervised control module. Mount one or
two modules in a BB -2F cabinet (optional). Mount up to six mod-
ules on a CHS -6 chassis in a BB -6F cabinet.
CRF -300-6: Six -relay control module (Form -C relays). Mount
one or two modules in a BB -2F cabinet (optional). Mount up to
six modules on a CHS -6 chassis in a BB -6F cabinet.
NOTE: For more information on Compatible Addressable Devices
for use with the MS-9050UD, see the following data sheets (docu-
ment numbers): AD355 (DF -52386), BG-12LX (DF -52013), CMF -
300 -6 (DF -52365), CRF -300-6 (DF -52374), CMF/CRF Series (DF -
52130), CP355 (DF -52383), H355 Series (DF -52385), 1300 (DF -
52389), MMF-300 Series/MOF-300 (DF -52121), MMF-300-10
(DF -52347), MMF-302-6 (DF -52356), SD3551SO355T (DF-
52384).
DF52384).
ADDRESSABLE DEVICE ACCESSORIES
End -of -Line Resistor Assembly (R -47K and R -3.91K): The
47k ohm assembly supervises the MMF-300, MDF -300, MMF-
301, and CMF -300 module circuits. The 3.9k ohm assembly
supervises the MMF-302 module circuit. These resistors are
included with each module.
Power Supervision Relay: Supervises the power to 4 -wire
smoke detectors and notification appliances.
Wiring Requirements
While shielded wire is not required, it is recommended that all
SLC wiring be twisted -pair to minimize the effects of electrical
interference. Refer to the panel manual for wiring details.
DF -5241811 -1/27/12 — Page 3 014
SYSTEM SPECIFICATIONS
System Capacity
• Intelligent Signalling Line Circuits ......................................... 1
• Addressable device capacity .............................................. 50
• Programmable software zones ........................................... 20
• Annunciators.........................................................................8
Electrical Specifications
AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-9050UDE:
240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2)
with 600 V insulation. Nonpower -limited, supervised.
Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger
Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two
18 AH batteries.)
Communication Loop: Supervised and power -limited.
Notification Appliance Circuits: Terminal Block provides con-
nections for two NACs, Style Y (Class B) or Style Z (Class A).
Special Application power. Power -limited, supervised circuitry.
Maximum signaling current per circuit: 2.5 A. End -of -Line Resis-
tor: 4.7k ohm, % watt (P/N 71252 UL listed) for Style Y (Class B)
NAC. Refer to the Fire•Lite Device Compatibility Document for
listed compatible devices.
Two Programmable Relays and One Fixed Trouble Relay:
Contact rating: 2.0 A 0 30 VDC (resistive), 0.5 A 0 30 VAC
(resistive). Form -C relays, nonpower -limited, nonsupervised.
Cabinet Specifications
Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72'
(1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65'
(42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE):
22.00' (55.88 cm.) high x 19.65• (49.91 cm.) wide.
Shipping Specifications
Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.)
high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep.
Temperature and Humidity Ranges
This system meets NFPA requirements for operation at 0 —
49•C/32 —120•F and at a relative humidity 93% t 2% RH (non -
• condensing) at 32•C t 2•C (90•F t 3•F). However, the useful
life of the system's standby batteries and the electronic compo-
nents may be adversely affected by extreme temperature ranges
and humidity. Therefore, it is recommended that this system and
its peripherals be installed in an environment with a normal room
temperature of 15 — 27•C/60 — 800F.
NEPA Standards
The MS-9050UD(E) complies with the following NFPA 72 Fire
Alarm Systems requirements:
— LOCAL (Automatic, Manual, Waterflow and Sprinkler
Supervisory).
— AUXILIARY (Automatic, Manual and Waterflow) (requires
4XTMF).
— REMOTE STATION (Automatic, Manual and Waterflow)
(Where a DACT is not accepted, the alarm, trouble and
supervisory relays may be connected to UL 864 listed
transmitters. For reverse polarity signaling of alarm and
trouble, 4XTMF is required.)
— PROPRIETARY (Automatic, Manual and Waterflow).
— CENTRAL STATION (Automatic, Manual and Waterflow,
and Sprinkler Supervised).
— OT, PSDN (Other Technologies, Packet -switched Data Net-
work)
Agency Listings and Approvals
The listings and approvals below apply to the basic MS-
9050UD(E) control panel. In some cases, certain modules may
not be listed by certain approval agencies, or listing may be in
process. Consult factory for latest listing status.
• UL: S624
• FM approved
• CSFM: 7165-0075:210
• MEA: 442-06-E
NOTE., See DF -60445 for ULC -listed model.
FlreL te® Alarms® and System Sensor® are registered trademarks of
Honeywell International Inc. Microsoft® and Windows® are registered
trademarks of the Microsoft Corporation. .
02012 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
I�O �oo�
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
61btI11= tl
QQAIITT SYSTEMS
All specifications are subject to change without notice.
Made in the U.S. A.
For more information, contact Fire -Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
www.firelite.com
Page 4 of 4 — DF -5241811 -1/27/12
a to 191. Met
Features — All models
• UL Listed commercial fire alarm applications.
• Meets NFPA 72 requirements
• Direct reporting to DynaNet receiver across DynaNet
wireless mesh network
• Each Subscriber acts as transmit-ter/receiver/
repeater
• Simple and fast activation on network
• On board status LEDs for easy set up
• 8 programmable zone inputs - 7788 F
• 4 programmable zone inputs and 4 reverse polarity
inputs
• Easy programming via DynaNet handheld
programmer or PC
• Rugged metal housing ideal for any commercial fire
alarm application
Model 7788 F-ULP with IntelliPro Fire also
includes
• IntelliPro Fire transmits full alarm data from virtually
any fire alarm panel digital communicator
• Alarm format support for Contact ID, Pulse, or
Bosch Modem Ile or Modem Illa2
• Easy installation in DynaNet subscriber
• Operates in applications with or without a phone line
, 1, nQ
IDYKA ,- EU
�grc
WIRELESS
ALARM MONITORING
Wireless mesh networking is an innovative technology
adopted by many industries with applications that
need to communicate data over a large geographic
area with a high level of reliability at a low total cost
of ownership.
The advanced design and 2 -way communications
capability provides easy installation, expansion, and
management when compared to alternative
communication methods, both wired and wireless.
ADVANCED WIRELESS
ALARM MONITORING
The DynaNet mesh radio
network offers unmatched
reliability and speed in delivering
...�.�
wireless alarm signals to a central
I I'Ft
station without third party fees or
- s�
reliance on networks owned by,1
companies outside the security,
and fire alarm industry. DynaNet
f�
7788 F Series Smart Subscriber
=��"`' ' 11
1 Transceivers provide the wireless
communication link between the
fire alarm panel and the central station
receiver
The 7788 F Series
is ideal for most commercial fire alarm applications. Each 7788 F
Series Subscriber is housed in a full sized, red, locked, steel cabinet
and supports a range of alarm panel inputs including EOL fire, EOL
supervised, and direct voltage from the panel (nonfire applications).
SUPERVISED OPERATION
DynaNet Subscribers offer fully supervised operation that includes
monitoring of operating power (both primary AC power and battery
backup) and the connection to the radio network. Each Subscriber
"checks in" with the DynaNet central station receiver at least once
every 24 hours, The supervision check in time can be set for as often
as once per minute and, because DynaFire owns the wireless network,
there is no additional cost for air time to transmit supervisory signals.
FULL DATA REPORTING FROM ALARM PANEL DIGITAL
DIALER
Model 7788 F-ULP comes equipped with an IntelliPro Fire Full Data
Module (DynaNet-7794) which enables reporting of full alarm data
captured from the fire alarm panel's digital communicator. IntelliPro
Fre supports most alarm communication formats including Contact
ID, Pulse, as well as Bosch Modem Ile and Modem IIla2.
DynaNet Models
Model Description
4 Zone Fire Alarm
7744F Subscriber with
4 reverse polarity
inputs
7788 F 8 Zone Fire Alarm
Subscriber
7788 F-ULP 7788 F Fire Alarm
Subscriber with IntelliPro Fre
full data module
Optional Accessories
7041 E Subscriber Handheld
Programmer
7794 IntelliPro Fire Full
Data Module
C
�L us M1
LISTED NFPW
10)y KA O P, E
"A. p,
V �
7788 F SERIES SUBSCRIBERS
Dimensions
• 13,25"H x 8.5"W x 4.3"D
(34cm H x 21.5cm W x 11 cm D)
Weight
• Approx. 7 pounds (3.2 kilograms),
excludes battery.
Radio Frequency
• Standard Frequency Range:
450-470MHz (others available)
• Output Power - 2 Watts
(others available)
Antenna
• Included 2.5 db tamper resistant antenna
mounts on enclosure
• Multiple remote antenna options available
Power Input
• 16,5VAC, 40VA (transformer not included)
Backup Battery
• Will charge 12V battery up to 7.5 AH.
Requires 12VDC 7.5 AH battery for UL
864.
Alarm Signal Inputs (subscriber)
• 7788 F - 8 individually programmable
zonesL
UL Standards
• UL 864 Edition 9 - Standard for Control
Units and Accessories for Fire Alarm
Systems
• UL 365 - Standard for Police Station
Connected Burglar Alarm Units and
Systems
• UL 1681 - Standard for Central Station
Burglar Alarm Units
Antenna Cut / Communication
Trouble Output
• Form C relay; fail secure; rated for 24 VDC
1 A resistive
Reset Button
• Located on main circuit board.
Operating Temperature
• 00 to 50° C (320 to 122°F)
Storage Temperature
• -10° to 60° C (14° to 140°F)
Relative Humidity
• 0 to 85% RHC, Non Condensing
7794 INTELLIPRO FIRE
Input / Output Connections
• RJ11 connection to AES subscriber for
module data and power
• RJ11 connector for Handheld
Programmer/PC programming
• RJ31 X Telco connections - T and R both
in and out via terminal strip and RJ45
• Alarm Panel digital communicator T and R
both in and out via terminal strip and RJ45
• Trouble output: Form C relay detects K
Subscriber is off the network
Alarm Formats
• Support for Contact ID and Pulse formats
as well as Modem Ile and Modem Illa2
converted to CID
Size
• 2.8 x 5.0 inches (7.1 cm x 12.7cm)
Power Requirements
• 12 VDC nominal - primary and backup
power provided by the DynaNet 7788 Fr
49
D U U V Ae
CT l
Wireless
Alarm Monitoring
SENSORO
Indoor Selectable -
Output Horns,
Strobes, and
Horn Strobes for
Wall Applications
System Sensor L -Series audible visible notification
products are rich with features guaranteed to cut
installation times and maximize profits with lower
current draw and modern aesthetics.
Features
• Updated Modern Aesthetics
• Small profile devices for Horns and Horn Strobes
• Plug-in design with minimal intrusion into the back box
• Tamper-resistant construction
• Automatic selection of 12- or 24 -volt operation at 15 and 30
candela
• Field -selectable candela settings on wall units:
15, 30, 75, 95, 110, 135, and 185
• Horn rated at 88+ dBA at 16 volts
IF
I
R
E
• Rotary switch for horn tone and two volume selections
• Mounting plate for all standard and all compact wall units
• Mounting plate shorting spring checks wiring continuity before
device installation
• Electrically Compatible with legacy SpectrAlert and SpectAlert
Advance devices
• Compatible with MDL3 sync module
• Listed for wall mounting only
Aaencv Listinas
UGNUMB
llSM
urnove•
55512
FM •pppw•d •u•pf
TI&I65MM
54011
for ALERT modal
7MI65305M
3057383.3057072
The System Sensor L-Serles offers the most versatile and
easy-to-use line of horns, strobes, and horn strobes in the industry
with lower current draws and modern aesthetics. With white and red
plastic housings, standard and compact devices, and plain, FIRE,
and FUEGO-printed devices, System Sensor L -Series can
meet virtually any application requirement.
The L -Series line of wall -mount horns, strobes, and horn strobes
include a variety of features that increase their application versatility
while simplifying installation. All devices feature plug-in designs
with minimal intrusion into the back box, making installations fast
and foolproof while virtually eliminating costly and time-consuming
ground faults.
To further simplify installation and protect devices from construction
damage, the L -Series utilizes a universal mounting plate for all
models with an onboard shorting spring, so installers can test wiring
continuity before the device is installed.
Installers can also easily adapt devices to a suit a wide range
of application requirements using field -selectable candela settings,
automatic selection of 12- or 24 -volt operation, and a rotary switch
for horn tones with two volume selections.
L -Series Specifications
General -
L -Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/e -inch back box, 4 x 4 x 1'/cinch back box, 4 -inch
octagon back box, or double -gang back box. L -Series compact products shall mount to a single -gang 2 x 4 x 1 Winch back box. A universal
mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be
used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L -Series
products, when used with the Sync•Circuit- Module accessory, shall be powered from a non -coded notification appliance circuit output
and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 -volt -rated notification appliance circuit outputs
shall operate between 8.5 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor
L -Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply.
Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185.
Strobe
The strobe shall be a System Sensor L -Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe
shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible
signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and
associated lens/reflector system.
Mom Strobe Combination
The horn strobe shall be a System Sensor L -Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective
service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act
requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist
of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a
temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe
models shall operate on a coded or non -coded power supply.
Synchronization Module
The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module
shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns
on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8 -inch back box. The module shall also
control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more
synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.
Physical[Electrical Specifications
Standard Operating Temperature 32°F to 1200F (0°C to 49°C)
Humidity Range
10 to 93% non -condensing
Strobe Flash Rate
1 flash per second
Nominal Voltage
Regulated 12 DC or regulated 24 DC/FWR1z
Operating Voltage Range
8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)
Operating Voltage Range MDL3 Sync Module
8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal)
Input Terminal Wire Gauge
12 to 18 AWG
Wall -Mount Dimensions (Including lens)
5.6'L x 4.7'W x 1.91-D (143 mm L x 119 mm W x 49 mm D)
Compact Wall -Mount Dimensions (Including lens)
5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D)
Mom Dimensions
5.6-L x 4.7-W x 1.25'D (143 mm L x 119 mm W x 32 mm D)
Compact Mom Dimensions
5.25' L x 3.45"W x 1.25"D (133mm L x 88mm W x 32mm D)
1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs.
2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd.
UL Current Draw Data
Candela
8-175 Volts
DC
16-33 Volts
DC FWR
Candela 15
88
43 60
Range 30
143
63 83
75
N/A
107 136
95
N/A
121 155
110
N/A
148 179
135
N/A
172 209
185
N/A
222 257
8-17.5 Volts 16-33 Volts
8-17.5 Volts 16-33 Volts
Sound Pattem dB DC DC FWR
Temporal
High
39
44
54
Temporal
Low
28
32
54
Non -Temporal
High
43
47
54
Non -Temporal
Low
29
32
54
3.1 KHz Temporal
High
39
41
54
3.1 KHz Temporal
Low
29
32
54
3.1 KHz Non -Temporal
High
42
43
54
3.1 KHz Non -Temporal
Low
28
29
54
Coded
High
43
47
54
3.1 KHz Coded
High
42
43
54
DC Input
15cd
30cd
15cd
30cd
75cd
95cd
110cd
135cd
185cd
Temporal High
98
158
54
74
121
142
162
196
245
Temporal Low
93
154
44
65
111
133
157
184
235
Non -Temporal High
106
166
73
94
139
160
182
211
262
Non-Temportal Low
93
156
51
71
119
139
162
190
239
3.1 K Temporal High
93
156
53
73
119
140
164
190
242
3.1 K Temporal Low
91
154
45
66
112
133
160
185
235
3.1 K Non -Temporal High
99
162
69
90
135
157
175
208
261
3.1 K Non -Temporal Low
93
156
52
72
119
138
162
192
242
FWR Input
16-33 Volts
15cd
30cd
75cd
95cd
110cd
135cd
185cd
Temporal High
83
107
156
177
198
234
287
Temporal Low
68
91
145
165
185
223
271
Non -Temporal High
111
135
185
207
230
264
316
Non-Temportal Low
79
104
157
175
197
235
283
3.1 K Temporal High
81
105
155•
177
196
234
284
3.1 K Temporal Low
68
90
145
166
186
222
276
3.1K Non -Temporal High
104
131
177
204
230
264
326
3.1 K Non -Temporal Low
77
102
156
177
199
234
291
Horn Tones and Sound Output Data
6-17.5 16-33
Switch Volts Volts
Position
Sound Pattern
dB
DC
DC
FWR
1
Temporal
High
84
89
89
2
Temporal
Low
75
83
83
3
Non -Temporal
High
85
90
90
4
Non -Temporal
Low
76
84
84
5
3.1 KHz Temporal
High
83
88
88
6
3.1 KHz Temporal
Low
76
82
82
7
3.1 KHz Non -Temporal
High
84
89
89
8
3.1 KHz Non -Temporal
Low
77
83
83
9'
Coded
High
85
90
90
10'
3.1 KHz Coded
High
84
89
89
' Settings 9 and 10 are not available on the 2 -wire horn strobes.
L -Series Dimensions
all
11It�
� IIII
Compact Strobe / Hom Strobe
4.70
1.91
1.25
5.67
W
WI -
2
1.25
.27a��o
00000
•
Compact Hom
- r -
`two J' I\il
Strobe / Hom Strobe Hom
L -Series Ordering Information
Notes:
All -P models have a plain housing (no 'FIRE' marking on cover)
All -SP models have *FUEGO' marking on cover
All -ALERT models have 'ALERT' marking on cover
SYSTEn� 3825 Ohio Avenue • St. Charles, IL 60174 OW17symmsr•ror.
Phone: 800 SENSOR2 •Fax: 630-377-6495 P,owp�imoms t00 gvAV r4ft6.vdtyw"wr "m
• w dnm• wodW rtdmttum�..aero nr wm m d fu mu dmd.
�. SENSOR www.systemsensor.com Avosesso3•0W1?
sescriplion
model
llescnption
Wall Hom Strobes
Homs
P2RL
2 -Wire, Horn Strobe, Red
HRL
Horn, Red
P2WL
2 -Wire, Horn Strobe, White
HWL
Horn, White
P2GRL
2 -Wire, Compact Horn Strobe, Red
HGRL
Compact Horn, Red
P2GWL
2 -Wire, Compact Horn Strobe, White
HGWL
Compact Horn, White
P2RL-P
2 -Wire, Horn Strobe, Red, Plain
Accessories
P2WL-P
2 -Wire, Horn Strobe, White, Plain
TR -2
Universal Wall Trim Ring Red
P2RL-SP
2 -Wire, Horn Strobe, Red, FUEGO
TR -2W
Universal Wall Trim Ring White
\ P2WL-SP
2 -Wire, Horn Strobe, White, FUEGO
SBBRL
Wall Surface Mount Back Box, Red
Wall Strobes
SBBWL
Wall Surface Mount Back Box, White
y SRL
Strobe, Red
SBBGRL
Compact Wall Surface Mount Back Box, Red
SWL
Strobe, White
SBBGWL
Compact Wall Surface Mount Back Box, White
SGRL
Compact Strobe, Red
SGWL
Compact Strobe, White
SRL-P
Strobe, Red, Plain
SWL-P
Strobe, White, Plain
SRL-SP
Strobe, Red, FUEGO
SWL-CLR-ALERT Strobe, White, ALERT
Notes:
All -P models have a plain housing (no 'FIRE' marking on cover)
All -SP models have *FUEGO' marking on cover
All -ALERT models have 'ALERT' marking on cover
SYSTEn� 3825 Ohio Avenue • St. Charles, IL 60174 OW17symmsr•ror.
Phone: 800 SENSOR2 •Fax: 630-377-6495 P,owp�imoms t00 gvAV r4ft6.vdtyw"wr "m
• w dnm• wodW rtdmttum�..aero nr wm m d fu mu dmd.
�. SENSOR www.systemsensor.com Avosesso3•0W1?
smCo r Mrs", Bufldogng woore
THHN, THWN-2, T90 Nylon, TWN75 (cUL)
Thermoplastic Insulated, Nylon Sheathed Heat, Moisture, Oil & Gasoline Resistant 600 Volt Copper
Product Description:
Windy City Wire Type THHN or THWN-2 conductors are primarily used in conduit as branch circuits in commercial
or industrial applications, as specified by the National Electrical Code.
Type THHN or THWN-2 are available as stranded in sizes 14 AWG — 10 AWG, and as solid in sizes 14 — 10 AWG.
The conductors are soft -annealed, stranded or solid copper and are insulated with a tough, heat and moisture resistant
polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied.
Specifications:
Windy City Wire Type THHN or THWN-2 meets applicable ASTM specifications, UL Standard 83, UL Standard 758,
and UL Standard 1063. The conductors are Gasoline and Oil Resistant II, and have a voltage rating to 600 volts.
All THHN is UL and cUL listed.
Conductor
PVC Insulation Nylon
Jacket
Nominal Ampacity
90'
C_ Approx.
Net 1
AWG Size No.
Stands_
Thickness (Mils) Tliickness
MDIs)
r
O:D. (Mils) T60/1HIIVN:2
Weight Per
MFT
City Wire
1,000'
oo�tilM�a'rkers
in
standard stocking
sizyeI; RackP,ackrBoxes,
with!Asccending/DescendingISe`guentii'(3
0 — 1',000 (bo;th
.]��404i&J�f'+�iii�_
w�ayyys��Otheflpuvt
upsava II able upon
}que�'y�.��'
�/..1�`':-.i�'S%ry..
_•,:��,
.'.~i:%}S`�'s4
Uft—
o � usT�® � c ®� us LisTE®
MADE IN IM U.sA.
BAT Series Batteries
Sealed Lead -Acid
General
BAT Series Batteries are Power -Sonic brand batteries. BAT
Series (or Power -Sonic brand) batteries are recommended for
secondary power or backup power for all NOTIFIER fire alarm
control equipment.
Features
• Provide secondary power for control panels.
• Sealed and maintenance -free.
• Overcharge protected.
• Easy handling with leak -proof construction.
• Ruggedly constructed, high -impact case (ABS).
• Long service life.
• Compact design.
DN -6933:1) • E-205
NOTIFIER
by Honeywell
asp"
Ordering Information
BAT -1250 -SP: 10 -unit bulk pack of BAT -1250 (12 V 5 AH).
AT 1270 -BP: 5 -unit bulk ack of BAT 1270 12 V 7 AH .
Agency Listings and Approvals r.BAT-12120-BP: 4 -unit bulk pack of BAT -12120 (12V 12 AH).
The listings and approvals below apply to BAT Series Batter- SAT -12180 -SP: 2 -unit bulk pack of BAT -12180 (12 V 18 AH).
fes. In some cases, certain modules may not be listed by cer-
tain approval agencies, or listing may be in process. Consult BAT -12260 -BP: 2 -unit bulk pack of BAT -12260 (12 V 26 AH).
factory for latest listing status. BAT -11 2550: single battery (12 V 55 AH).
• UL Recognized Components: MH2O845 (Power -Sonic). BAT -11 21000: single battery (12 V 100 AH).
Part Number Reference & Specifications
Part
Number
Power -
Sonic Pali
Number
Battery
Description
DIMENSIONS
Nominal
Nominal Capacity
Voltage V @ 20 hr.
rate A.H.
Width Depth Height Height over Weight
terminal
in. mm In. mm In. mm in. mm Ib. kg.
BAT -1250
PS -1250
12
sealed
2.
0
.98
0
.2
I ENEsea e
BAT -12120
PS -12120
12
12
sealed
5.95
151
3.86
98
3.7
94
3.94
100
7.92
3.59
BAT -12180
PS -12180
12
18
sealed
7.13
181
3.00
76
6.59
167
6.59
167
12.6
5.72
BAT -12260
PS -12260
12
26
sealed
6.5
167
j6.97
177
j4.92
j 125
4.92
125
17
7.71
BAT -12550
PS -12550
12
55
sealed
9.04
230
15.45
138
18.15
1207
8.98
228
36
16.33
BAT -121000
PS -121000
1 12
100
sealed
12
305
6.6
168
18.15
207
18.98
228
68
30.84
DN -6933:1).02/28/2013 — Page 1 of 2
Discharge Characteristic Curves at 20eC (68eF9
For 6V For OV
eaeery Baumy
6.3 +3.0 i
i
6.0 +2.0 j
o.osc
5.5 1+.0 . I 1 -0.10C .
040c i
SO f00 0600
6 2c +c
1 2 4 6 e 10 20 40 6o 2 4 6 a 10 20
N.- Mimin Hour
Dleoherge Time
PS -121000 Shelf -Life and Storage
„ AROMM■■■■■
Standing Period (Months)
PS -121000 Discharge Characteristics
F5
0
11.0
20
OA
eA
S.0
1.2 2.4 6 12 24 36 461 2 4 6 610 20 40
in h�
Discharge Time
debnObnar
Is ar001edd
to help recover
6A caindly
ro revue hm
opacity. D0 no
,a,
reach
Us arae.
6
Effect of Temperature on Capacity
120
110
e0
40
s
20
0
0.05c
0.10 c
0.25 c
0.50 c
I
a
>3
.40 30 -20 -10 0 10 20 30 40 50 60
Temperetme Ve)
NOTIFIER® Is a registered trademark of Honeywell international Inc.
Batteries display trademarks of the manufacturer.
02013 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
ISO 9oo1 This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
I�p�la b All specifications are subject to change without notice.
QUAIITT SYSTEfits
For more information, contact Notifier. Phone: (203) 484.7161, FAX: (203) 464-7116.
www.notHier.com
Page 2 of 2 — DN -6933:D • 02/28/2013
LOCAL BUSINESS TAX RECEIPT
CITY OF CASSELBERRY
' 95 TRIPLET LAKE DRIVE
CASSELBERRY, FLORIDA 32707
Business name: DYNAFIRE INC
Location address: 109 CONCORD DR #B
City/State: - CASSELBERRY FL 32707-3214
DYNAFIRE INC
109 CONCORD DR
CASSELBERRY FL 32707-3214
ISSUE DATE: September 06, 2016
EXPIRATION DATE: September 30, 2017
TAX RECEIPT # CLASSIFICATION FEES PAID
17-00006531 CONSTRUCTION 115.76
17-00011162 SEMINOLE COUNTY FEE B 45.00
LICENSE COMMENTS AND RESTRICTIONS:
INSTALL FIRE ALARM SYSTEMS AND SPRINKLER SYSTEMS
STATE LICENSE NO. EF20000528
In7PORTANT: THIS TAX RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS.
Jeff Atwater Casia Sinco
CELIEF FINANCIAL OFFICER BUREAU CHIEF
Julius Halas Keitb McCarthy
DIVISION DIRECTORW SAFETY PROGRAM MANAGER
FLORIDA DEPARTMENT OF FINANCIAL SERVICES
DIVISION OF STATE FIRE MARSHAL
200 East Gaines Street - Tallahassee,"Florida 32399-0342
Tel. 85OA 13-3644 Fax. 850-410-2467
THIS CERTIFIES THAT
CERTIFICATE OF COMPETENCY
OFFICIAL COPY
Charles A. Daimler
109-B Concord Drive
Casselberry FL 32707
BUSINESS ORGANIZATION: DynaFire, Inc.
Contractor II is limited to the execution of contracts requiring the ability to layout, fabricate, install, inspect, alter,
repair, and service water sprinkler systems, water spray systems, foam -water sprinkler systems, foam -water spray
systems, standpipes, combination standpipes and sprinkler risers, all piping that is an integral part of the system
beginning at the point of service, sprinkler tank heaters, air lines, thermal systems used in connection with sprinklers,
and tanks and pumps connected thereto, excluding pre-engineered systems.
Issue Date:
07/01/2016
Type:
07
Class:
12
County:
Seminole
License/Permit #:
FPC 16-000015
Expiration Date:
06/30/2018
Chief Financial Officer
1 109-B Concord Drive
®
DYNAFIRE Casselberry, 32707 DYNA4jETI AlarmM
407.830.66 500 Alarm Monitoring
DynaFire.com
Proposal Document (05/17/2017)
Project: Sanford Community Center
1101 Pine Ave.
Sanford, Fl. 32773
To: Sanford Community Center
Attn: Paul Hoyer
Paul@hclm.org
Scope: Turnkey (Specifications --)
Prices were established per the Design Documents dated (00-00-00), unless otherwise noted below. The quantity of
devices is based on the contract drawings design. DynaFire will install all devices and circuits per all applicable codes.
DynaFire, Inc. Standard Terms and Conditions apply to this quotation. Proposal and any resulting Contract/PO shall be
subject the General Terms and Conditions attached hereto. Proposal is based on a mutually agreeable contract. Pricing
is valid for (60) days from date of quote.
Scope Clarifications:
1. This proposal is based on upgrading the existing conditions to meet minimum code requirements.
Existing/damaged FACP to be replaced with same, additional A/V's (6) to be installed in Rest Rooms and
corridors, and re-installation/connection of existing conduit and wiring of devices. Overall check of existing
system, test, and final.
2. Connection to a DynaNet Radio for Wireless monitoring not included in this proposal. A separate contract will be
supplied for those services.
3. A complete set of shop drawings along with submittals and permit application will be submitted to the local AHJ
for review and approval.
4. DynaFire will be responsible for installing any required boxes or conduit needed for the proper installation of the
fire alarm devices.
5. A complete test of all devices shall be completed prior to any inspections being conducted or scheduled with the
local AHJ.
6. All engineering and inspection fees are included in this proposal. Permit fees to be assessed by the local AHJ.
That cost will be passed directly to the GC/Owner.
7. DynaFire Inc. will warranty all new parts and labor for a period of (1) year from the date of final acceptance by
the local AHJ.
8. The proposal includes surge protection for the fire alarm system.
Pricing (TurnKev):
Base Fire Alarm System: $3,157.51
Cassclberry I Largo I Jacksonvillc I Pompano I Melbourne
EF200005281 FL PE26483 I NICET IV 99907 1 FP16481600012009 I FPC15-000057
Customer's Responsibilities:
1. To provide a complete conduit raceway with pull -string where required. N/A
2. To provide and install all backboxes, troughs and termination cabinets as required. N/A
3. To provide and install all required underground raceway's -with pull -string. N/A
4. To provide and install any necessary fire caulking and/or fire sleeving. N/A
5. To install fire alarm panel back -boxes and any weatherproof back -boxes. N/A
6. To provide and terminate all 120 VAC circuits as required.
7. To provide a common ground for all surge protection equipment.
8. If a lift is required, customer to supply or a separate quote will be provided if desired. N/A
9. To provide electronic CAD files for the creation of engineered shop -drawings.
10. To provide copy of Building Permit(s), Recorded NOC(s) and current Schedule(s).
11. To obtain all Florida PE Seal documentation from the engineer of record as required by the "AHJ" for use of
permitting. N/A
DvnaFire, Inc. will provide the followine:
Engineered Shop Drawings
Y
Taxes
Y
Product Data Submittals
Y
Labor for Installation
Y
Florida PE Seal
N
Programming
Y
Permitting Fees
N
Functional Pre -Test
Y
Equipment/Wire/Materials
Y
Fire Inspector Test
Y
Panel Back Boxes
Y
End User Training
Y
'If customer desires to provide any of the options listed above, DynaFire will provide a credit or deduct.
Casselberry I Largo I Jacksonville I Pompano I Melbournc
EF20000528 I FL PE26483 I NICET IV 999071 FP16481600012009 I FPC15-000057
Thank you for allowing DynaFire, Inc. to offer our products and services.
1506 yeelaxp
Sincerely,
DynaFire, Inc.
Prepared By: Bob Seekamp
Email: Bob.Seekamp@DvnaFire.com
Office: 407-637-8380
Cell: 407-754-7492
Signed:
Date:
9-30-1-7
"Protecting lives and property through leading technologies and quality service while creating valuable relationships"
- DynaFire, Inc. Mission Statement
Casselberry I Largo I Jacksonville I Pompano I Melbourne
EF200005281 FL PE26483 I NICET IV 999071 FP16481600012009I FPC15-000057