HomeMy WebLinkAbout1101 Pine Ave (3)114 )fl�j I I P CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION ECEIVE JUL 0 3 2011 Application No: Documented Construction Value: $ 3,157.51 Job Address: 1101 Pine Ave., Sanford, FL 32771 Parcel ID: 25-19-30-5AG-130C-0000 Historic District: Yes ❑ No ❑■ Residential ❑ Commercial ■❑ Type of Work: New X Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Replacing existing FACP with same. Reconnect existing devices and connect new devices to FACP. Working under building permit #16-1697. Plan Review Contact Person: Nicole Sealy Phone: 407-637-8396 Fax: Title: Permit Tech Email: engineering@dynafire.com Property Owner Information Name Community Improvement Assn of Seminole County Inc. Phone: Street: 1590 Rochelle Lane City, State Gip: Oviedo, FL 32765 Name DynaFire, Inc. Street: 109B Concord Dr. Resident of property0 O �, Contractor Information City, State Gip: Casselberry, FL 32707 Name: Street: City, St, Zip: Bonding Company: Address: Phone: 407-830-6500 Fax: State License No.: EF20000528 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5'^ Edition (2014) Florida Building Code Revised: June 30. 2015 Permit Application DATE: 713117 BUSINESS/PROJECT NAME: // ADDRESS: o/ X CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 PERMIT NUMBER: CONTACT NAME: PHONE: PLAN REVIEW INFORMATION [) CONSTRUCTION [ ]C/O FIRE ALARM [ ] FIRE SPRINKLER [ ] HOOD DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES ( 3N TOTAL FEES: '7j-, aU [ )PAINT BOOTH [ )TANK NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. _ Signature ot'Otirner/Agent Date Signa Print Owner/Agent's Name Signature of Notary -State of Flonda Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Print Co ractor/A ent's Name Kk6die o KRISTYN S. WELCH �.qy P 0• ` �%•- Notary Public •Stale o1 Florida c; • = Commission # GG058981 ;�• "� M Comm. 'plies Jan 9. 2021 Y OF " Bonded th 0 National Notary Assn. Co r nally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[-] Gas[] Roof ❑ Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: Flood Zone: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures, Fire Sprinkler Permit: Yes No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Fire Alarm Permit: Yes ❑ No ❑ UTILITIES: WASTE WATER: FIR 7/ BUILDING: ?- • /? Revised June 30.2015 Pennit Application CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION D 1 Application No: l I -' 0 Q -I Documented Construction Value: $ 4,300 Job Address: 1101 Pine Avenue Historic District: Yes K No ❑ Parcel ID: Residential ❑ Commercial ❑■ Type of Work: New ❑ Addition ❑ Alteration ❑ Repair 9 Demo ❑ Change of Use ❑ Move ❑ Description of Work: Replace Hvac per plans Plan Review Contact Person: R; r- Title: tu_d,eY Phone: f-9"�'��' �!6ax: Email: (iie�t��(a�t)� Itt/C, Com Property Owner Information Name Community Inprovement Association Phone: Street: 1101 Pine Avenue Resident of property?: No City, State Zip: Sanford FL Contractor Information Name RirANew-r-A� NlnrrlSsgAtJ Phone: Sir- 922-- y`tra R Street: b o"La i e,.,< �I" _ Fax: City, State Zip: i g,tLn 6t/l R?D.d PE( State License No.: CAC 19 18566 9 ArchitecVEngineer Information Name: CPH, Inc. Street: 500 West Fulton Street City, St, Zip: Sanford FL 32771 Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of applicationandthe codeineffect as of that date: 5'^ Edition (2014) Florida Building Code Revised: June 30, 2015 ` _ �� V (,— I Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Sig4.rnttactor/ ate Print Signature aDate �UBLtC STATE OF FLORIDA COMMIt FF979289 Expires 4/4/2020 Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas[] Roof ❑ Construction Type: Occupancy Use: Flood Zone: - Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes❑ No ❑ # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: Revised: lune 30, 2015 Permit Application q D Yll4AFIRE OFFICE 109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com DYNAfilET I PERMIT PRODUCT DATA SUBMITTALS FIRE ALARM SYSTEM DATE: June 23, 2017 PROJECT: Sanford Community Center CUSTOMER: City of Sanford REPRESENTATIVE: Bob Seekamp PREPARED BY: Miguel A Vargas Casselberry I Largo I Jacksonville I Pompano I Melbourne EF20000528 I FL PE26483 I NICET 1V 99907 1 FP 16481600012009 1 FPC15-000057 Wlrolew Alarm MOnkering Sanford Community Center Fire Alarm System Submittal ITEM PART # MANUF. DESCRIPTION . Panel Equipment 1 MS-9050UD€ FIRE -LITE Addressable Fire Alarm Control Panel w/backup batteries 2 7788F-ULP AES Wireless Fire Alarm Communicator w/ back-up batteries Notification Appliance Devices 2 SRL Wall Mount strobe - Red @15CD Wire 1 Notification Windy City Wire 14 AWG, THHN Batteries & Calculations 2 Batteries Notifier BAT -1270 MS-905OUD(E) Fire Alarm Control Panel with DACT General The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicatorlfransmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire-Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK -CD Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off -she via the public switched tele- phone network. Any personal computer with Windows" 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire•l-Ke Upload/Download software kit PK -CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walk -test data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/ciy, box transmitter. (4XTMF) New options include a UL listed printer, PRN -6F and the new IPDACT Internet Monitoring module.The FireWatch Series Inter- net monitoring modules IPDACT 2 and IPDACT 2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE. Unless otherwise specified, the term MS-905OUD is used in this data sheet to refer to both the MS-905OUD and the MS- 9050UDE FACPs. For MS-9050UDC, refer to DF -60445. Features • Listed to UL Standard 864, 9th edition. • Auto -program (learn mode) reduces installation time. Reports two devices set to the same address. • On -board DACT. • Two independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits. • Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. • Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. • Two programmable relays and one fixed trouble relay. • Built-in Programmer. • Telephone Line Active LEDs. • EIA -232 PC interface. • Integral 80 -character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings control. • History file with 500 event capacity. • Automatic detector sensitivity testing (NFPA 72 compliant). • Automatic device type -code verification. DF -52418:E1 • Al -20 8FIre-LITerAWMS by Honeywell • Point trouble identification. • Waterflow selection per module point. • Alarm verification selection per detector point. • Maintenance alert warns when smoke detector dust accumu- lation is excessive. • One-person audible or silent walk test with walk -test log and printout. • System alarm verification selection per detector point. • PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant). • Up to eight ANN -BUS annunciators • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator. • UploadlDownload (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP • Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. • 50 addressable device capacity (any combination of address- able detectors and modules). • Compatible with Fire•Lite's addressable devices (refer to SLC Wiring Manuak NOTIFICATION APPLIANCE CIRCUITS (NACS) • Two independently programmable output circuits. Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) – Door Holder Service (cannot be used for notification appliances) – Aux Power Source (cannot be used for notification appliances) • Silence Inhibit and Autosilence timer options. • Continuous, March Time, Temporal or California code for main circuit board NACS with two-stage capability. • Selectable strobe synchronization per NAC. • 2.5 A total power for NACs. NOTE. Maximum or total 24VDC system power shared between all NAC circuits and the ANN -BUS is 2.7 A. DF-5241e:E1 •1/27/12 — Page 1 of 4 B6 -12U( Addressable Manual Pull Station Multi -Modules • CRF -300.6 Six -Relay Control Module • CMF -300.6 Six -Circuit Supervised Control Module • MMF-302-6 Six -Zone Interface Module • MMF-300-10 Ten -Input Monitor Module MS-905OUD ADDRESSABLE FIRE ALARM CONTROL PANEL Page 2 of 4 — DF -52416:E1 •1/27/12 PROGRAMMING AND SOFTWARE • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Two programmable Form -C relay outputs. • 20 software zones. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. • OFFLINE PROGRAMMING: Create the entire program in your office using a Windows based software package(order programming kit PK -CD, containing PS -Tools, separately). Upload/download system programming locally. User interface LED INDICATORS • AC Power (green) • Fire Alarm (red) • Supervisory (yellow) • Trouble (yellow) • Alarm Silenced signals (yellow) KEYPAD • 16 key alpha -numeric pad • Acknowledge/Step • Alarm Silenced • Drill (Manual Evacuate) • Reset (lamp test) Product Line Information MS-9050UD(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag contain- ing screws, cables, key, etc., manual. (For MS-9050UDC, refer to DF -60445.) PK -CD: Contains PS -Tools programming software for Win- dowsQD*based PC computer (cable not included). DP -51050: Optional dress panel for the MS-9050UD. TR -CE: Optional trim ring for semi -flush mounting. BB -2F: Optional cabinet for one or two modules. BB -6F: Optional cabinet for up to six modules mounted on CHS -6 chassis. BB -26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB -55F: Battery box, houses two 55 AH batteries CHS -6: Chassis, mounts up to six mufti -modules in a BB -6F cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead -acid bat- teries with a rating of 55 to 120 AH. Requires additional BB -55F for mounting. BAT Series: Batteries, see data sheet DF -52397. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN -6F: UL listed compatible event printer. Uses tractor -fed paper. IPDACT, IPDACT212UD Internet Monitoring Module: Mounts In bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether - net internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df -52424 for more information.) IPBRKT. Mounting kit for IPDACT 212UD in common enclosure. IPSPLT: Y adaptor option allows connection of both panel dialer outputs to one IPDACT 2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the transformer. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. ANN -SEC: Optional secondary ANN -BUS interface module. Note: Used only with firmware 3.0 or higher. COMPATIBLE ANNUNCIATORS ANN -80(-W): Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un -shielded. (Basic model is red; order -W version for white; see DF -52417.) ANN -UO: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF -52430.) ANN -LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF -60241.) ANN -RILED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF -60241.) ANN-RLY: Relay Module provides 10 programmable Form -C relays. Can be mounted inside the cabinet. (See DF -52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF -52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low -profile ionization smoke detector. SD355: Addressable low -profile photoelectric smoke detector. SD355T: Addressable low -profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. H355: Fast -response, low -profile heat detector. H355R: Fast -response, low -profile heat detector with rate -of - rise option. H355HT: Fast -response, low -profile heat detector that activates at 190°F/88°C. AD355: Low -profile, intelligent, "Adapt" multi -sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sen- sitivity test. D355PL: InnovairFlex low -flow non -relay duct -detector housing; includes SD355R. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order SD355R separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA4 rating. Watertight. (Order SD355R separately.) MMF-300: Addressable Monitor Module for one zone of nor- mally -open dry -contact initiating devices. Mounts in standard 4.0' (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF -300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302A: Similar to MMF-300A. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires reset - table 24 VDC power. Refer to the Device Compatibility Docu- ment for listed compatible devices and quantity limitation. CMF -300: Addressable Control Module for one Style Y2 (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. CRF -300: Addressable relay module containing two isolated sets of Form -C contacts, which operate as a DPDT switch. Mounts directly to a 4.0' (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten -input monitor module. Mount one or two mod- ules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. MMF-302-6: Six -zone interface module. Mount one or two mod- ules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. CMF -300-6: Six -circuit supervised control module. Mount one or two modules in a BB -2F cabinet (optional). Mount up to six mod- ules on a CHS -6 chassis in a BB -6F cabinet. CRF -300-6: Six -relay control module (Form -C relays). Mount one or two modules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. NOTE: For more information on Compatible Addressable Devices for use with the MS-9050UD, see the following data sheets (docu- ment numbers): AD355 (DF -52386), BG-12LX (DF -52013), CMF - 300 -6 (DF -52365), CRF -300-6 (DF -52374), CMF/CRF Series (DF - 52130), CP355 (DF -52383), H355 Series (DF -52385), 1300 (DF - 52389), MMF-300 Series/MOF-300 (DF -52121), MMF-300-10 (DF -52347), MMF-302-6 (DF -52356), SD3551SO355T (DF- 52384). DF52384). ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R -47K and R -3.91K): The 47k ohm assembly supervises the MMF-300, MDF -300, MMF- 301, and CMF -300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4 -wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DF -5241811 -1/27/12 — Page 3 014 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signalling Line Circuits ......................................... 1 • Addressable device capacity .............................................. 50 • Programmable software zones ........................................... 20 • Annunciators.........................................................................8 Electrical Specifications AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-9050UDE: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower -limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited. Notification Appliance Circuits: Terminal Block provides con- nections for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry. Maximum signaling current per circuit: 2.5 A. End -of -Line Resis- tor: 4.7k ohm, % watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A 0 30 VDC (resistive), 0.5 A 0 30 VAC (resistive). Form -C relays, nonpower -limited, nonsupervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72' (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE): 22.00' (55.88 cm.) high x 19.65• (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49•C/32 —120•F and at a relative humidity 93% t 2% RH (non - • condensing) at 32•C t 2•C (90•F t 3•F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27•C/60 — 800F. NEPA Standards The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet -switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S624 • FM approved • CSFM: 7165-0075:210 • MEA: 442-06-E NOTE., See DF -60445 for ULC -listed model. FlreL te® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. . 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 61btI11= tl QQAIITT SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Fire -Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — DF -5241811 -1/27/12 a to 191. Met Features — All models • UL Listed commercial fire alarm applications. • Meets NFPA 72 requirements • Direct reporting to DynaNet receiver across DynaNet wireless mesh network • Each Subscriber acts as transmit-ter/receiver/ repeater • Simple and fast activation on network • On board status LEDs for easy set up • 8 programmable zone inputs - 7788 F • 4 programmable zone inputs and 4 reverse polarity inputs • Easy programming via DynaNet handheld programmer or PC • Rugged metal housing ideal for any commercial fire alarm application Model 7788 F-ULP with IntelliPro Fire also includes • IntelliPro Fire transmits full alarm data from virtually any fire alarm panel digital communicator • Alarm format support for Contact ID, Pulse, or Bosch Modem Ile or Modem Illa2 • Easy installation in DynaNet subscriber • Operates in applications with or without a phone line , 1, nQ IDYKA ,- EU �grc WIRELESS ALARM MONITORING Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2 -way communications capability provides easy installation, expansion, and management when compared to alternative communication methods, both wired and wireless. ADVANCED WIRELESS ALARM MONITORING The DynaNet mesh radio network offers unmatched reliability and speed in delivering ...�.� wireless alarm signals to a central I I'Ft station without third party fees or - s� reliance on networks owned by,1 companies outside the security, and fire alarm industry. DynaNet f� 7788 F Series Smart Subscriber =��"`' ' 11 1 Transceivers provide the wireless communication link between the fire alarm panel and the central station receiver The 7788 F Series is ideal for most commercial fire alarm applications. Each 7788 F Series Subscriber is housed in a full sized, red, locked, steel cabinet and supports a range of alarm panel inputs including EOL fire, EOL supervised, and direct voltage from the panel (nonfire applications). SUPERVISED OPERATION DynaNet Subscribers offer fully supervised operation that includes monitoring of operating power (both primary AC power and battery backup) and the connection to the radio network. Each Subscriber "checks in" with the DynaNet central station receiver at least once every 24 hours, The supervision check in time can be set for as often as once per minute and, because DynaFire owns the wireless network, there is no additional cost for air time to transmit supervisory signals. FULL DATA REPORTING FROM ALARM PANEL DIGITAL DIALER Model 7788 F-ULP comes equipped with an IntelliPro Fire Full Data Module (DynaNet-7794) which enables reporting of full alarm data captured from the fire alarm panel's digital communicator. IntelliPro Fre supports most alarm communication formats including Contact ID, Pulse, as well as Bosch Modem Ile and Modem IIla2. DynaNet Models Model Description 4 Zone Fire Alarm 7744F Subscriber with 4 reverse polarity inputs 7788 F 8 Zone Fire Alarm Subscriber 7788 F-ULP 7788 F Fire Alarm Subscriber with IntelliPro Fre full data module Optional Accessories 7041 E Subscriber Handheld Programmer 7794 IntelliPro Fire Full Data Module C �L us M1 LISTED NFPW 10)y KA O P, E "A. p, V � 7788 F SERIES SUBSCRIBERS Dimensions • 13,25"H x 8.5"W x 4.3"D (34cm H x 21.5cm W x 11 cm D) Weight • Approx. 7 pounds (3.2 kilograms), excludes battery. Radio Frequency • Standard Frequency Range: 450-470MHz (others available) • Output Power - 2 Watts (others available) Antenna • Included 2.5 db tamper resistant antenna mounts on enclosure • Multiple remote antenna options available Power Input • 16,5VAC, 40VA (transformer not included) Backup Battery • Will charge 12V battery up to 7.5 AH. Requires 12VDC 7.5 AH battery for UL 864. Alarm Signal Inputs (subscriber) • 7788 F - 8 individually programmable zonesL UL Standards • UL 864 Edition 9 - Standard for Control Units and Accessories for Fire Alarm Systems • UL 365 - Standard for Police Station Connected Burglar Alarm Units and Systems • UL 1681 - Standard for Central Station Burglar Alarm Units Antenna Cut / Communication Trouble Output • Form C relay; fail secure; rated for 24 VDC 1 A resistive Reset Button • Located on main circuit board. Operating Temperature • 00 to 50° C (320 to 122°F) Storage Temperature • -10° to 60° C (14° to 140°F) Relative Humidity • 0 to 85% RHC, Non Condensing 7794 INTELLIPRO FIRE Input / Output Connections • RJ11 connection to AES subscriber for module data and power • RJ11 connector for Handheld Programmer/PC programming • RJ31 X Telco connections - T and R both in and out via terminal strip and RJ45 • Alarm Panel digital communicator T and R both in and out via terminal strip and RJ45 • Trouble output: Form C relay detects K Subscriber is off the network Alarm Formats • Support for Contact ID and Pulse formats as well as Modem Ile and Modem Illa2 converted to CID Size • 2.8 x 5.0 inches (7.1 cm x 12.7cm) Power Requirements • 12 VDC nominal - primary and backup power provided by the DynaNet 7788 Fr 49 D U U V Ae CT l Wireless Alarm Monitoring SENSORO Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24 -volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts IF I R E • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Aaencv Listinas UGNUMB llSM urnove• 55512 FM •pppw•d •u•pf TI&I65MM 54011 for ALERT modal 7MI65305M 3057383.3057072 The System Sensor L-Serles offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L -Series can meet virtually any application requirement. The L -Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L -Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with two volume selections. L -Series Specifications General - L -Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/e -inch back box, 4 x 4 x 1'/cinch back box, 4 -inch octagon back box, or double -gang back box. L -Series compact products shall mount to a single -gang 2 x 4 x 1 Winch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L -Series products, when used with the Sync•Circuit- Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L -Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L -Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Mom Strobe Combination The horn strobe shall be a System Sensor L -Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8 -inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical[Electrical Specifications Standard Operating Temperature 32°F to 1200F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1z Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (Including lens) 5.6'L x 4.7'W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (Including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Mom Dimensions 5.6-L x 4.7-W x 1.25'D (143 mm L x 119 mm W x 32 mm D) Compact Mom Dimensions 5.25' L x 3.45"W x 1.25"D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data Candela 8-175 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Sound Pattem dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155• 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 6-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9' Coded High 85 90 90 10' 3.1 KHz Coded High 84 89 89 ' Settings 9 and 10 are not available on the 2 -wire horn strobes. L -Series Dimensions all 11It� � IIII Compact Strobe / Hom Strobe 4.70 1.91 1.25 5.67 W WI - 2 1.25 .27a��o 00000 • Compact Hom - r - `two J' I\il Strobe / Hom Strobe Hom L -Series Ordering Information Notes: All -P models have a plain housing (no 'FIRE' marking on cover) All -SP models have *FUEGO' marking on cover All -ALERT models have 'ALERT' marking on cover SYSTEn� 3825 Ohio Avenue • St. Charles, IL 60174 OW17symmsr•ror. Phone: 800 SENSOR2 •Fax: 630-377-6495 P,owp�imoms t00 gvAV r4ft6.vdtyw"wr "m • w dnm• wodW rtdmttum�..aero nr wm m d fu mu dmd. �. SENSOR www.systemsensor.com Avosesso3•0W1? sescriplion model llescnption Wall Hom Strobes Homs P2RL 2 -Wire, Horn Strobe, Red HRL Horn, Red P2WL 2 -Wire, Horn Strobe, White HWL Horn, White P2GRL 2 -Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2 -Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2 -Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2 -Wire, Horn Strobe, White, Plain TR -2 Universal Wall Trim Ring Red P2RL-SP 2 -Wire, Horn Strobe, Red, FUEGO TR -2W Universal Wall Trim Ring White \ P2WL-SP 2 -Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White y SRL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no 'FIRE' marking on cover) All -SP models have *FUEGO' marking on cover All -ALERT models have 'ALERT' marking on cover SYSTEn� 3825 Ohio Avenue • St. Charles, IL 60174 OW17symmsr•ror. Phone: 800 SENSOR2 •Fax: 630-377-6495 P,owp�imoms t00 gvAV r4ft6.vdtyw"wr "m • w dnm• wodW rtdmttum�..aero nr wm m d fu mu dmd. �. SENSOR www.systemsensor.com Avosesso3•0W1? smCo r Mrs", Bufldogng woore THHN, THWN-2, T90 Nylon, TWN75 (cUL) Thermoplastic Insulated, Nylon Sheathed Heat, Moisture, Oil & Gasoline Resistant 600 Volt Copper Product Description: Windy City Wire Type THHN or THWN-2 conductors are primarily used in conduit as branch circuits in commercial or industrial applications, as specified by the National Electrical Code. Type THHN or THWN-2 are available as stranded in sizes 14 AWG — 10 AWG, and as solid in sizes 14 — 10 AWG. The conductors are soft -annealed, stranded or solid copper and are insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied. Specifications: Windy City Wire Type THHN or THWN-2 meets applicable ASTM specifications, UL Standard 83, UL Standard 758, and UL Standard 1063. The conductors are Gasoline and Oil Resistant II, and have a voltage rating to 600 volts. All THHN is UL and cUL listed. Conductor PVC Insulation Nylon Jacket Nominal Ampacity 90' C_ Approx. Net 1 AWG Size No. Stands_ Thickness (Mils) Tliickness MDIs) r O:D. (Mils) T60/1HIIVN:2 Weight Per MFT City Wire 1,000' oo�tilM�a'rkers in standard stocking sizyeI; RackP,ackrBoxes, with!Asccending/DescendingISe`guentii'(3 0 — 1',000 (bo;th .]��404i&J�f'+�iii�_ w�ayyys��Otheflpuvt upsava II able upon }que�'y�.��' �/..1�`':-.i�'S%ry.. _•,:��, .'.~i:%}S`�'s4 Uft— o � usT�® � c ®� us LisTE® MADE IN IM U.sA. BAT Series Batteries Sealed Lead -Acid General BAT Series Batteries are Power -Sonic brand batteries. BAT Series (or Power -Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features • Provide secondary power for control panels. • Sealed and maintenance -free. • Overcharge protected. • Easy handling with leak -proof construction. • Ruggedly constructed, high -impact case (ABS). • Long service life. • Compact design. DN -6933:1) • E-205 NOTIFIER by Honeywell asp" Ordering Information BAT -1250 -SP: 10 -unit bulk pack of BAT -1250 (12 V 5 AH). AT 1270 -BP: 5 -unit bulk ack of BAT 1270 12 V 7 AH . Agency Listings and Approvals r.BAT-12120-BP: 4 -unit bulk pack of BAT -12120 (12V 12 AH). The listings and approvals below apply to BAT Series Batter- SAT -12180 -SP: 2 -unit bulk pack of BAT -12180 (12 V 18 AH). fes. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult BAT -12260 -BP: 2 -unit bulk pack of BAT -12260 (12 V 26 AH). factory for latest listing status. BAT -11 2550: single battery (12 V 55 AH). • UL Recognized Components: MH2O845 (Power -Sonic). BAT -11 21000: single battery (12 V 100 AH). Part Number Reference & Specifications Part Number Power - Sonic Pali Number Battery Description DIMENSIONS Nominal Nominal Capacity Voltage V @ 20 hr. rate A.H. Width Depth Height Height over Weight terminal in. mm In. mm In. mm in. mm Ib. kg. BAT -1250 PS -1250 12 sealed 2. 0 .98 0 .2 I ENEsea e BAT -12120 PS -12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT -12180 PS -12180 12 18 sealed 7.13 181 3.00 76 6.59 167 6.59 167 12.6 5.72 BAT -12260 PS -12260 12 26 sealed 6.5 167 j6.97 177 j4.92 j 125 4.92 125 17 7.71 BAT -12550 PS -12550 12 55 sealed 9.04 230 15.45 138 18.15 1207 8.98 228 36 16.33 BAT -121000 PS -121000 1 12 100 sealed 12 305 6.6 168 18.15 207 18.98 228 68 30.84 DN -6933:1).02/28/2013 — Page 1 of 2 Discharge Characteristic Curves at 20eC (68eF9 For 6V For OV eaeery Baumy 6.3 +3.0 i i 6.0 +2.0 j o.osc 5.5 1+.0 . I 1 -0.10C . 040c i SO f00 0600 6 2c +c 1 2 4 6 e 10 20 40 6o 2 4 6 a 10 20 N.- Mimin Hour Dleoherge Time PS -121000 Shelf -Life and Storage „ AROMM■■■■■ Standing Period (Months) PS -121000 Discharge Characteristics F5 0 11.0 20 OA eA S.0 1.2 2.4 6 12 24 36 461 2 4 6 610 20 40 in h� Discharge Time debnObnar Is ar001edd to help recover 6A caindly ro revue hm opacity. D0 no ,a, reach Us arae. 6 Effect of Temperature on Capacity 120 110 e0 40 s 20 0 0.05c 0.10 c 0.25 c 0.50 c I a >3 .40 30 -20 -10 0 10 20 30 40 50 60 Temperetme Ve) NOTIFIER® Is a registered trademark of Honeywell international Inc. Batteries display trademarks of the manufacturer. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I�p�la b All specifications are subject to change without notice. QUAIITT SYSTEfits For more information, contact Notifier. Phone: (203) 484.7161, FAX: (203) 464-7116. www.notHier.com Page 2 of 2 — DN -6933:D • 02/28/2013 LOCAL BUSINESS TAX RECEIPT CITY OF CASSELBERRY ' 95 TRIPLET LAKE DRIVE CASSELBERRY, FLORIDA 32707 Business name: DYNAFIRE INC Location address: 109 CONCORD DR #B City/State: - CASSELBERRY FL 32707-3214 DYNAFIRE INC 109 CONCORD DR CASSELBERRY FL 32707-3214 ISSUE DATE: September 06, 2016 EXPIRATION DATE: September 30, 2017 TAX RECEIPT # CLASSIFICATION FEES PAID 17-00006531 CONSTRUCTION 115.76 17-00011162 SEMINOLE COUNTY FEE B 45.00 LICENSE COMMENTS AND RESTRICTIONS: INSTALL FIRE ALARM SYSTEMS AND SPRINKLER SYSTEMS STATE LICENSE NO. EF20000528 In7PORTANT: THIS TAX RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS. Jeff Atwater Casia Sinco CELIEF FINANCIAL OFFICER BUREAU CHIEF Julius Halas Keitb McCarthy DIVISION DIRECTORW SAFETY PROGRAM MANAGER FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF STATE FIRE MARSHAL 200 East Gaines Street - Tallahassee,"Florida 32399-0342 Tel. 85OA 13-3644 Fax. 850-410-2467 THIS CERTIFIES THAT CERTIFICATE OF COMPETENCY OFFICIAL COPY Charles A. Daimler 109-B Concord Drive Casselberry FL 32707 BUSINESS ORGANIZATION: DynaFire, Inc. Contractor II is limited to the execution of contracts requiring the ability to layout, fabricate, install, inspect, alter, repair, and service water sprinkler systems, water spray systems, foam -water sprinkler systems, foam -water spray systems, standpipes, combination standpipes and sprinkler risers, all piping that is an integral part of the system beginning at the point of service, sprinkler tank heaters, air lines, thermal systems used in connection with sprinklers, and tanks and pumps connected thereto, excluding pre-engineered systems. Issue Date: 07/01/2016 Type: 07 Class: 12 County: Seminole License/Permit #: FPC 16-000015 Expiration Date: 06/30/2018 Chief Financial Officer 1 109-B Concord Drive ® DYNAFIRE Casselberry, 32707 DYNA4jETI AlarmM 407.830.66 500 Alarm Monitoring DynaFire.com Proposal Document (05/17/2017) Project: Sanford Community Center 1101 Pine Ave. Sanford, Fl. 32773 To: Sanford Community Center Attn: Paul Hoyer Paul@hclm.org Scope: Turnkey (Specifications --) Prices were established per the Design Documents dated (00-00-00), unless otherwise noted below. The quantity of devices is based on the contract drawings design. DynaFire will install all devices and circuits per all applicable codes. DynaFire, Inc. Standard Terms and Conditions apply to this quotation. Proposal and any resulting Contract/PO shall be subject the General Terms and Conditions attached hereto. Proposal is based on a mutually agreeable contract. Pricing is valid for (60) days from date of quote. Scope Clarifications: 1. This proposal is based on upgrading the existing conditions to meet minimum code requirements. Existing/damaged FACP to be replaced with same, additional A/V's (6) to be installed in Rest Rooms and corridors, and re-installation/connection of existing conduit and wiring of devices. Overall check of existing system, test, and final. 2. Connection to a DynaNet Radio for Wireless monitoring not included in this proposal. A separate contract will be supplied for those services. 3. A complete set of shop drawings along with submittals and permit application will be submitted to the local AHJ for review and approval. 4. DynaFire will be responsible for installing any required boxes or conduit needed for the proper installation of the fire alarm devices. 5. A complete test of all devices shall be completed prior to any inspections being conducted or scheduled with the local AHJ. 6. All engineering and inspection fees are included in this proposal. Permit fees to be assessed by the local AHJ. That cost will be passed directly to the GC/Owner. 7. DynaFire Inc. will warranty all new parts and labor for a period of (1) year from the date of final acceptance by the local AHJ. 8. The proposal includes surge protection for the fire alarm system. Pricing (TurnKev): Base Fire Alarm System: $3,157.51 Cassclberry I Largo I Jacksonvillc I Pompano I Melbourne EF200005281 FL PE26483 I NICET IV 99907 1 FP16481600012009 I FPC15-000057 Customer's Responsibilities: 1. To provide a complete conduit raceway with pull -string where required. N/A 2. To provide and install all backboxes, troughs and termination cabinets as required. N/A 3. To provide and install all required underground raceway's -with pull -string. N/A 4. To provide and install any necessary fire caulking and/or fire sleeving. N/A 5. To install fire alarm panel back -boxes and any weatherproof back -boxes. N/A 6. To provide and terminate all 120 VAC circuits as required. 7. To provide a common ground for all surge protection equipment. 8. If a lift is required, customer to supply or a separate quote will be provided if desired. N/A 9. To provide electronic CAD files for the creation of engineered shop -drawings. 10. To provide copy of Building Permit(s), Recorded NOC(s) and current Schedule(s). 11. To obtain all Florida PE Seal documentation from the engineer of record as required by the "AHJ" for use of permitting. N/A DvnaFire, Inc. will provide the followine: Engineered Shop Drawings Y Taxes Y Product Data Submittals Y Labor for Installation Y Florida PE Seal N Programming Y Permitting Fees N Functional Pre -Test Y Equipment/Wire/Materials Y Fire Inspector Test Y Panel Back Boxes Y End User Training Y 'If customer desires to provide any of the options listed above, DynaFire will provide a credit or deduct. Casselberry I Largo I Jacksonville I Pompano I Melbournc EF20000528 I FL PE26483 I NICET IV 999071 FP16481600012009 I FPC15-000057 Thank you for allowing DynaFire, Inc. to offer our products and services. 1506 yeelaxp Sincerely, DynaFire, Inc. Prepared By: Bob Seekamp Email: Bob.Seekamp@DvnaFire.com Office: 407-637-8380 Cell: 407-754-7492 Signed: Date: 9-30-1-7 "Protecting lives and property through leading technologies and quality service while creating valuable relationships" - DynaFire, Inc. Mission Statement Casselberry I Largo I Jacksonville I Pompano I Melbourne EF200005281 FL PE26483 I NICET IV 999071 FP16481600012009I FPC15-000057