Loading...
HomeMy WebLinkAbout1109 W 10 StCITY OF SANFORD RECEIVED BUILDING & FIRE PREVENTION ' PERMIT APPLICATION LJUN 2 1016 y Application No: 1 I Documented Construction Value: $ Job Address: 11( j�f _ DAK 2}. ^ nQk6 iFly 32� � Historic District: Yes ❑ No,� Parcel ID: -S -00 — O ResidentialKCommercial ❑ Type of Work: New E4 Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: ,rer0OP 123Q '<,hit (llf_ e.d a Q Plan Review Contact Person: u ) Z !.C& P Y Title: Phone: Fax: Prope Owner Information Name one: Street: UResident of property? City, State Zip: Name TOTAL HOME ROOFING Street: 165 W ST RD 434 City, State Zip: Contractor Information WINTER SPRINGS FL 32708 Phone: 4079603810 Fax: State License No.: CCC1330489 Architect/Engineer Information Name: Phone: Street: City, St, Zip: Bonding Company: Address: Fax: E-mail: Mortgage Lender. Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE' OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit most be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51b Edition (2014) Florida Building Code Revised: June 30,201 S Permit Application O V �:r NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public: records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction �"'1 and zonin �._ . 4 5 Signature of Owner/A t Date Si h.— of Co t Date �a 4� R4P-J PrintO /Agent's Name Y Signeitum of Notary -State of Florida Date ►*r "'ei,� •' CHRISTIW► MACAR MUR MY COMMISSION 1 FF 064139 * * EXPIRES: October 17.2017 Owner/Agent is Pe nown to Me r Produced ID Print Contras Age r Signature of Notary-Sta f Flonda Date ro��pr vue��C LUZ K. LOPEZ * MY COMMISSION 9 FF 959062 w �XPIIiC�B: Januery to. 2020 ,S'Eorv� kmeaiAi49ud4N 10" 5 Contractor/Agent is Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing[] Gas❑ Roof ❑ Construction Type: Total Sq Ft of Bldg; Occupancy Use: Min. Occupancy Load: Flood Zone: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures, Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: UTILITIES: -COMMENTS: Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: ENGINEERING: FIRE: BUILDING: Revised: June 30, 2015 Permit Application THIS INSTRUMENT PREPARED BY: Name: TOTAL HOME ROOFING Address: 165 W ST RD 434 Winter Springs. FL 32708 11ARYANNE 11ARSEr SE111NOLE COUNTY CLERK'OF CIRCUIT COURT 6 COMPTROLLER BK 8711 Ps 1784 (1Pgs) CLERK'a 2016064 NOTICE OF COMMENCEMENT RECORDEDT06/ 21/2016111:33:5, AN kECURDING FEES $1.0.00 State of Florida RECORDED BY jeckenre County of Seminole Permit Number: Parcel ID Number: 2.5-19::3Lt SRJA— O UUO— -2� The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) -r-0 f--4 Orr ,1 150 5+ 0F 14 GENERAL DESCRIPTION OF IMPROVEMENT: re -roof ONLY OWNER INFORMATI N: Name Qom. _1 hf-I Address Fee Simple Title Holder (if other than owner) Name. Address - CONTRACTOR: Name: Total Home Properties DBA Total Home Roofing Address. 165 W ST RD 434 Winter Springs, FL 32708 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates w To receive a copy of the Lienor's Notice as Provi 4d in Section 713.13(1)(b), Florida Statutes. J�N V Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless `' different date is r 2 specified) ,' WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. rte`";o!�q �f Owner's Signature Omer's Punted Name i " Y a� Florida Statute 713.13(1)(g).'The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead.' c s y �hs.1►�V�� y '1 tai 1`� State of FLORIDA County of SEMINOLE W `a O 00 Z The foregoing instrument wa cknowledged before me this day of 20 W F b 1 Y �� Che W s personally know e ❑ Z? o > o O: Name o1 person making statement Q ? W OR who has produced identification ❑ type of identification produced: 6 Cr W 8�-i 'P •�e4t. CHRISTINA MACARTHUR IdY C(, 131SSION 9 FF (',44159x o o a z Notary Signature o: g 7 EXviRF$: 0,',ober 17, 2017 w O�W v t! V y .n""0.•^ �R•0, i,� Ba. 9"j Tkti £4'�g,'l M171'ery Strrices ,n m POWER OF ATTORNEY Date: 6/15/16 I hereby name and appoint HELGA TORRES of TOTAL HOME ROOFING In fact to act for me and apply to the RE -ROOF permit. CITY OF SANFORD For work to be performed at a location described as: Parcel ID: 25-19230-5AH-0000-023B Subdivision: ROBINSONS SURVEY OF AN ADD TO SANFORD to be my lawful attorney. Building Department for a Owner of property and address: DALE REICHEL-1109 W 10TH ST, SANFORD FL 32771 And to sign my name and do all things necessary to this appointment. ROBERT DONOVAN CCC1330489 (Type or print name.eft tft)Fd contractor and license number) (Signature of certified contrac-erg The foregoing instrument was acknowledged before me this 15 day of_i5of 20_U,,,_ by Robert Donovan, who is personally known to me. State of Florida County of Seminole r°�rv`���� LUZK LOPEZ MY COMMISSION H FF 949082 EXPIRES: January 10, 2020 f,�fFOf F�OQ�f ft4od Thru 8udP1 N0W y SavkM (Notary signature) t: ` -" JUIV 2 z 2016 TOTAL HOME • RANGEANDSEMINOLE COUNTYOFFICE 407-960-3810 BREVARD COUNTY OFFICE • 321-452-9223 VOLUSIA COUNTY OFFICE 386-233-3244 Name: I— .- L DATE- ! ' Street / 0 V/. / 0 T H STeCFT CCC1330489 City/State/Zips(4N�` I` 0/ F� 3 Phone J �rVV n '• Home Cell Phone y O%-�a9 _g yb7 ob Emall DESCRIPTION ($ )AMOUNT ROOF Due Care taken to protect home exterior, shrubs and landscaping. Includes labor to remove existing shingle roof and haul off Includes Dumpster. Roll off dumpster for paver driveways Includes inspecting deck for damage nd enailing to code with 8D rin shank nails G A Includes replacing new ridge vents (Z �— i4 FOOT0F?-9Ia(0J5 uc , S �,r�,), Includes saving gutters, soffit, fascia on existing home (some damage may occur In construction) Includes replacing existing drip edge In hoice of Z >NN/�/ Beow v o1E- �t 4o�or Includes 11/4" roofing collated nailsF6/�rlxJ L,,, p�� Q W6 "f � 0 l %� � Includes installing new shingles in choice of color H� Includes replacing all lead boots and goose vents (does not include gas related vents)( 1' Includes new galvanized metal In all valleys Includes starter shingles and rige cap per code Includes obtaining and posting permit W=ocal jurisdiction Includes magnetically sweeping job site, cleaning out gutters and hauling away debris. SHINGLES Architectural halt Lifetime Shinglesrr 30m h UNDERIAYMENT Peel � LL V eA, LL GY S and stick 301b Fe MISC 0 e�JT(9-E FLAT i2volC /+(LF j 2/v5�►-ALL !� Z—i0LY IZQL Le -o 12oi4K' sYs-rt NCCItb>F Fv Q 1� wju C -z) - S HlfS l Deteriorated existing decking replaced at SS? per sheet of plywood Initial Deteriorated existing decking replaced at $ 5r per linear ft 'Does not Include painting to match -7/ 80 'Does not include any stucco repairs where deteriorated (lashing had to be replaced. WARRANTIES o -Free Gold IS yr non -prorated WORKMANSHIP INCLUDED Worry -Free Platinum 25 yr all inclusive $ 'Flat roofs cavy a 7 year wodunartship warranty N 6 r S I TT ,1 w INCLUDES NEW WIND MITIGATION INSPECTION TOTAL is(2,986""' rte— Aluminum -Fascia and Vinyl Soffit $ EASY FINANCING OPTIONS Blown in Insulation R $ ;. Monthl -Payment' Seamless Gutters $ 9.90%•APR' . $ 0 EzteFib Pain'Ttn' •Not Included In roof price unless specified 'Through Welts Fargo tank with approved credit •Fin cIng In st b mpl p to start of project. AIL Customer: Date: Total a Roofing Date: I HAVE READ AND UNDERSTAND THIS PROPOSAL, THE TERM AND CONDITIONS AND ALL DOCUMENT REFERENCED THEREIN AND AGREE TO BE BOUND BY THEIR TERMS. ACCEPTANCE OF PROPOSAL: The above prices, specifications and conditions are Satisfactory and are hereby accepted. Contractor is authorized to do the work as specified. By signing Customer acknowledges that Customer is the owper of the property where work is to be performed. ALL PAYMENTS ARE DUE UPON COMPLETION OF THE ROOF. Any delay In payments may result In a 1:5%•interest per 30 days Wind mitigations are not considered part of the project but offered as a service to our customers through;a•third.party certified licensed Inspection company and shall not be used as reason for any delay of final payment • This agreement constitutes the entire contract by and between contractor and owner and parties are not bound by oral expressions or aaent of either SCPA Parcel View: 25-19-30-5AH-0000-023B Page 1 of 2 Property Record Card rPANW00%CFAParcel: 2579-30•SAH-00000238 Owner. REICHEL DALE J WOR REICHEL CATHY Oe�Oi°OO1J� Property Address: 1109 W 10TH ST SANFORD, FL 32771 Parcel Information Parcel 2519-305AH-0000.023B Owner REICHEL DALE J WOR REICHEL CATHY Property Address 1109 W 10TH ST SANFORD, FL 32771 Mailing 114 PINEAPPLE CT LONGWOOD, FL 32750 Subdivision Name ROBINSONS SURVEY OF AN ADD TO SANFORD Tax District St-SANFORD DOR Use Code 01 -SINGLE FAMILY Exemptions - Seminole County GIS Legal Description E 50 FT OF W 150 FT OF N 120 FT OF LOT 23 ROBINSONS SURVEY OF AN ADD TO SANFORD PB 1 PG 93 Taxes Value Summary Tax Amount without SOH: $724.32 2015 Tax Bill Amount $724.32 Tax Estimotor Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value 2016 Working 2015 Certified Amount Qualified County General Fund Values Values Valuation Method $36.485 Cost/Market i Improved -1� -Cost/Market - Number of Buildings 1 1 1 Depreciated Bldg Value 528,568 $27,674 Depreciated EXFT Value $100 ' No $36.485 Land Value (Market) $7,917 1$7,917 ---- - - - -- - - -- -- - - -- --- 336.485 • - - ^ - - -- $O • Land Value Ag- - - - - - - - - - - -- - - j- - ^ -- - - -- JusVMarket Value' $36,485 $35,591 Portability Adj— 02850 ; 1218 ' so - - Save Our Homes Adj - Amendment 1 Adj — ISO - 1 s0 Yt50 i P6G Adj $0 11 s0 Assessed Value 1$36,485 j $35,591 Tax Amount without SOH: $724.32 2015 Tax Bill Amount $724.32 Tax Estimotor Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value I Exempt Values Taxable Value Amount Qualified County General Fund QUIT CLAIM DEED 336.485 - 10 $36.485 Schools i Improved 336.485 s0 $36.485 -------- •-- ---- ---•----------- -- 4-•--- - - -- ---- - - - - - --- - -- City Sanford $100 ' No $36.485 s0 $36.485 - -- -- --- ------ ----- - . SJWM(Saint Johns Water Management) ---- - - - -- - - -- -- - - -- --- 336.485 • - - ^ - - -- $O • - - $36.485 - - - - - - - - - - -- - - j- - ^ -- - - -- - t r - — - -- - - - - -- ADMINISTRATIVE DEED County Bonds 02850 ; 1218 336.485 3100 No $36.485 -__-.__ - ___ --..-_--_-- - - -__.-_ y -- __ . . _ - -_____ ... - Sales Description Date Book Page Amount Qualified Vac/Imp QUIT CLAIM DEED 3/1/2008 06950 0035 $100 1 No i Improved WARRANTY DEED - - - 11/1/2006 106484 1502 - 325,000 Yes Improved - CORRECTIVE DEED 12/1/2002 04635 1967 $100 ' No Improved CORRECTIVE DEED 12/1/2002 WARRANTY DEED 3/1/2002 04635 - 11969 + 04494 1273 3100 , No $13,000 No NN Improved roved WARRANTY DEED --- - - 3/1/2002 - -- 04494 - 1084 __ ---- $3,500 No -s - Improved -- ADMINISTRATIVE DEED 11/1/1994 02850 ; 1218 3100 No Improved -__-.__ - ___ --..-_--_-- - - -__.-_ y -- __ . . _ - -_____ ... - -_-.}______ _ PROBATE RECORDS 7/1/1994 02807 2127 $100 No Improved Find Comparable Sales Land i -- Method. Frontage Depth Units Units Price Land Value FRONT FOOT d DEPTH 50.00 120.00 0 $174.00 $7,917 http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=2519305AH0000023B 6/21/2016 7/10/2015 Florida Building Code-Ordine R0ijda r)pM nWd SCIS Home I Log In I User Registration I Not Topics Submit Surcharge Stats B Facts . Publications I FOC Staff SCIS Site Map - Links I Search Prof.' dal ®Product Approval USER: Public user Regulation protluct Approval Menu > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida license Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL16709-R2 Revision 2014 Approved CertainTeed Corporation -Roofing 18 Moores Road Malvern, PA 19355 (610) 651-5847 mark.d.harner@saint-gobain.com Mark Harrier mark.d.harner@saint-gobain.com Mark Harper 1400 Union Meeting Road P.O. Box 1100 Blue Bell, PA 19422 (215) 274-2443 Mark.D.Harner@saint-gobain.com Roofing Modified Bitumeystem Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE -59166 UL LLC 07/03/2017 John W. Knezevich, PE 4. Validation Checklist - Hardcopy Received R!" ASTM D6162 2000 ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2008 ASTM D6509 2009 FM 4470 1992 FM 4474 2004 https:/Mrww.11oridabuilding.org/pr/pr_app dN.aspx?param=wGEVXOwlDqu8obl%2flZm6Tv250ccWynek2f7EijnwRnMlzClOjXmYnFadQ%3d%3d 1/2 7/10/2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building Code Online Method 1 Option D 03/16/2015 03/24/2015 03/26/2015 06/22/2015 FL of Model, Number or Name Description 16709.1 Flintlastic Modified Bitumen SBS and APP modified bitumen roof systems Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL16709 R2 11 2015 03 FINAL Al ER CERTAINTEED MODBIT FL16709- Approved for use outside HVHZ: Yes R2.Ddf Impact Resistant: N/A Verified By: Robert Nieminen PE -59166 Design Pressure: +N/A/ -97.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports pertains to the maximum design pressure for one FL16709 RZ AE 2015 03 FINAL ER CERTAINTEED MODBIT FL16709- particular assembly for use in Zone 1 (field area) R2.Ddf of the roof. Refer to ER Appendix for all systems Created by Independent Third Party: Yes and attachment limitations. 2.) Refer to ER Section 5 for Limits of Use. enck Nett Contact Us • • 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850.487-1824 The State of Florida is an WEED employer. Coovrlaht 2007.2013 State of Flonda.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact $50.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455. F.S. must provide the Department with an email address of they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: ® ®®— CreditSAFE haps://www.floridabuilding.orglpr/pr_app M.aspx',,Wam=wGEVXQvADqu8obl%2flZm6Tv25QccWyn%2f7EiijnwRnMlzCIOjXmYnFadQ%3d%3d 212 Q0T1mN1TYJERD EVALUATION REPORT CertainTeed Corporation 18 Moores Road Malvern, PA 19355 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report C40730.12.13 -R2 FL16709-R2 Date of Issuance: 12/02/2013 Revision 2: 03/11/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Flintlastic• Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus 14 -page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 •.e;1K OF, ••'W - The facsimile seal appearing was authorized R, .. C!r :?`: by Robert Niemmen. P E. on 03/11/2015 C '' ' A t••'•s' J� This does not serve as an electronically signed document. Signed. :gyp„�7 Vj1LE `� seated hardcopres have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. VTRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Flintlastic° Modified Bitumen Roof Systems, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6162 2000 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.11.2 Physical Properties ASTM D6509 2009 1519.11 Attachment Requirements RAS 117 1995 3. REFERENCES: iniint Examination Reference Date ERD (TST6049) Physical Properties 07290.01.08 01/16/2008 ERD (7576049) Physical Properties C10080.09.08 09/04/2008 ERD (TST6049) FM 4470/4474 C8370.08.08 -RI 10/05/2009 ERD (7576049) FM 4470/4474 C30330.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 3539.12.03-R1 04/15/2011 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C46090.11.13 -A 11/20/2013 FM (7571867) FM 4470/4474 3048520 09/19/2013 MTI (TST2508) Physical properties DX08C4A 03/22/2004 MTI (TST2508) Physical properties DX20E3A 03/22/2004 MTI (TST2508) Physical properties DX20E3A-001 01/04/2006 MTI (TST2508) Physical properties AX31G8A 08/21/2008 MTI (TST2508) Physical properties AX31G8D 09/05/2008 MTI (TST2508) Physical properties AX32GBF 06/05/2009 MTI (TST2508) Physical properties AX21G8C 01/28/2011 PRI (TST5878) Physical Properties CTC -032-02-01 01/16/2008 PRI(TST5878) Physical Properties CTC -034.02-01 11/24/2008 PRI(TST5878) Physical Properties CTC -066-02-01 08/08/2011 PRI(TST5878) Physical Properties CTC -067-02-01 08/08/2011 PRI(TST5878) Physical Properties CTC -068-02-01 08/08/2011 PRI(TST5878) Physical Properties CTC -070.02-01 08/08/2011 PRI(TST5878) Physical Properties CTC -071.02-01 08/08/2011 PRI(TST5878) Physical Properties CTC -093-02-01 08/08/2011 PRI(TST5878) Physical Properties CTC -116-02-01 04/03/2012 PRI(TST5878) Physical Properties CTC -183-02-01 10/04/2013 UL, I.I.C. (QUA9625) Quality Assurance Service Confirmation, R11656 Exp. 07/03/2017 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic° Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. Exterior Research and Design, I.I.C. Evaluation Report 040710.12.13-R2 CertiJkate oJAuthor4otion i19S03 FL16709-R2 Revision 2: 03/11/2015 Page 2 of 4 rTRINITYleRo Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 040710.12.13-R2 FL16709-R2 Revision 2: 03/11/2015 Page 3 of 4 TABLE 1: ROU -GOODS FOR FLINTLASTIC• MODIFIED BITUMEN ROOF SYSTEMS Type Product Reference Spec ication Grade Type Base Sheets Flintlastic SA NailBase ASTM D4601 N/A II Glasbase'" Base Sheet ASTM D4601 N/A II All Weather/Empire'" Base ASTM D4601 N/A II Flexiglas'" Base ASTM D4601 N/A II Flintlastic'" Base 20 ASTM D4601 N/A It Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II Yosemite Venting Base ASTM D4897 N/A II Ply Sheets Flintglas Ply Sheet Type IV ASTM D2178 N/A IV Flintglas Premium Ply Sheet Type VI ASTM 02178 N/A VI Base/Ply Membranes (APP) Flintlastic APP Base T ASTM D6509 N/A N/A Flintlastic STA ASTM D6222 S I Flintlastic STA Plus ASTM D6222 S I Cap Membranes (APP) Flintlastic STA ASTM D6222 5 I Flintlastic STA Plus ASTM D6222 S I Flintlastic GTA ASTM D6222 G I Flintlastic GTA CoolStar'" ASTM D6222 G I Flintlastic GTA -FR ASTM D6222 G I Flintlastic GTA -FR CoolStar'" ASTM 06222 G I Base/Ply Membranes (SBS) Flintlastic SA PI Base ASTM D1970 N/A N/A Black Diamond* Base Sheet ASTM D1970 N/A N/A Flintlastic SA Mid Ply ASTM D6163 S I Flintlastic Ultra Glass SA ASTM D6163 S I Flintlastic Base 20 ASTM D6163 S I Flintlastic Base 20 T ASTM D6163 S I Flintlastic FR Base 20 T ASTM D6163 S I Flintlastic Ultra Poly SMS Base Sheet ASTM D6164 S I Cap Membranes (SBS) Flintlastic FR Dual Cap ASTM D6162 G I Flintlastic SA Ca FR ASTM D6163 G I Flintlastic SA Cap FR CoolStar'" ASTM D6163 G I Flintlastic'Cap 30 ASTM D6163 G I Flintlastic Cap 30 CoolStar'" ASTM D6163 G I Flintlastic FR Cap 30 ASTM D6163 G I Flintlastic FR Cap 30 CoolStar'" ASTM D6163 G I Flintlastic FR Cap 30 T ASTM 06163 G I Flintlastic FR Cap 30 T CoolStar'" ASTM D6163 G I Flintlastic SA Cap ASTM D6164 G I Flintlastic SA Cap CoolStar'" ASTM D6164 G I Flintlastic FR -P ASTM D6164 G I Flintlastic FR -P CoolStar'" ASTM D6164 G I Flintlastic GMS ASTM D6164 G I Flintlastic GMS CoolStar'" ASTM D6164 G I Flintlastic GTS ASTM D6164 G 11 Flintlastic GTS CoolStar'" ASTM D6164 G II Flintlastic GTS -FR ASTM D6164 G 11 Flintlastic GTS -FR CoolStar'" ASTM D6164 G 11 Flintlastic Premium FR -P ASTM D6164 G 11 Flintlastic Premium FR -P CoolStar'" ASTM D6164 G 11 Flintlastic Premium GMS ASTM 06164 G 11 Flintlastic Premium GMS CoolStar'" ASTM D6164 G II Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 040710.12.13-R2 FL16709-R2 Revision 2: 03/11/2015 Page 3 of 4 ��TRINITYJERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.6 The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. This is already addressed in the Appendix tables via "N/A" reference if the baseline system is "Not Applicable" to Zone 1 design pressure requirements. 5.7 For existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX -1. 5.8 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES -1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.9 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Flintlastic° Modified Bitumen roof systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations / Conditions of Use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. System listings are based on allowable wind loads per FBC 1609 and a 2 to 1 margin of safety per FBC 1504.9. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the named CW entity for manufacturing facilities covered by F.A.C. Rule 611520-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (414) 248-6409, karen.buchmann@us.ul.com - THE 14 -PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- Exterior EPORT- Exterior Research and Design, I.I.C. Evaluation Report 040710.12.13-R2 Certificate ofAuthorization #9S03 FL16709-RZ Revision 2:03/11/201S Page 4 of 4 QOTRINITYIERD' APPENOIx 1: ATTACHMENT REQUIREMENTS FOR WINO UPLIFT RESISTANCE Table Deck Application Type Description Page 1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4-5 2 Wood New, Reroof (Tear -Off) or Recover C Mech Attached Insulation, Bonded Roof Cover 6-8 3 Wood New, Reroof (Tear -Off) or Recover 0 Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 9-10 4 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11-12 5 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-14 The followine notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite or gypsum -based roof board that meets the QA requirements of F.A.C. Rule 61G20- 3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.8, when installed with the roof cover. 3. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 4. The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. This is already addressed in the tables that follow via "N/A" reference if the baseline system is "Not Applicable" to Zone 1 design pressure requirements. S. For existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX -1. 6. For Recover Applications using System Type 0, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 7. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report 040710.12.13-R2 for F1.16709-112 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 1 of 14 TABLE A: GERTAINTEEO FUNTIASTIC- MODIFIED BITUMEN COMPONENTS Ji: APPLICATION METHODS Reference Layer Material Application BP -AA Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 (Base and Ply sheets, Asphalt- Hot asphalt at 20-40lbs/square Applied) Ply Flintglas Ply Sheet Type IV; Fliniglas Premium Ply Sheet Type VI Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS -AA (SBS, Asphalt -Applied) Hot asphalt at 20-40 lbs/square Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Cap Flintlastic FR -P; Flintlastic FR -P CoolStar; Flintlastic Premium FR -P; Flintlastic Premium FR -P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Base Flintlastic Base 20 T; Flintlastic FR Base 20 T S8S-TA Torch -Applied Ply Flintlastic Base 20 T; Flintlastic FR Base 20 T Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar, Flintlastic GTS -FR; Flintlastic (SBS, Torch -Applied) Cap GTS -FR CoolStar; FlintClad Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report 040710.12.13-R2 for F1.16709-112 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 1 of 14 ��TRINITYJERD 8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. The following summary is the basis for the attachment tables herein. Table 8 assumes a directionality factor Kd = 0.85, no topographical variations Kzt = 1.0, roof slope < 7' for enclosed buildings, roof slope < 2.4' for open buildings and unobstructed flow for open buildings, as defined in ASCE 7-10, TAtiIE A (CONTINUED): CERTAINTEEO fIINTIASTIC-ZMOOIFIEO BIttIMEN COMPONENTS & APPLICATION METHODS Reference layer Material Application APP -TA Base Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus Exposure Enclosure Torch -Applied (APP, Torch -Applied) Cap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA, Flintlastic GTA CoolStar; Flintlastic GTA -FR; Flintlastic GTA -FR CoolStar Ultimate Design Wind speed - V.% (mph) - FBC Figures 1609A,16098 or 16090 Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply 565 -SA (585, Self -Adhering) Ply Flintlastic SA PlyBase; Flintlastic SA Mid Ply Self -Adhering Open slope < 2.4' unobstructed now Cap Flintlastic SA Cap; Flintlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar 8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. The following summary is the basis for the attachment tables herein. Table 8 assumes a directionality factor Kd = 0.85, no topographical variations Kzt = 1.0, roof slope < 7' for enclosed buildings, roof slope < 2.4' for open buildings and unobstructed flow for open buildings, as defined in ASCE 7-10, Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report 040710.12.13-R2 for FL16709-112 Certificate of Authorization #9503 Revision 2: 03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 2 of 14 TAaIE B: ROOF CLI1DDIN DESIGN PRESSURES, AuOWAEIE STRESS DESIGN, PASO (PSF) Exposure Enclosure Roof Height (k) Ultimate Design Wind speed - V.% (mph) - FBC Figures 1609A,16098 or 16090 Zone 120 130 140 ISO 160 170 180 Open slope < 2.4' unobstructed now 0 < h < 30 1 -12.7 -14.9 -17.2 -19.8 -22.5 -25.4 -28.5 2 -19.4 -22.7 -26.4 -30.3 -34.4 -38.9 43.6 3 -38.0 -44.6 -51.7 -59.4 -67.5 -76.2 -85.5 30<h<40 1 -13.7 -16.1 -18.7 -21.5 -24.4 -27.6 -30.9 2 -21.0 -24.7 -28.6 -32.9 -37.4 -42.2 47.3 3 -41.2 48.4 -56.1 -64.4 -733 -82.8 -92.8 8 Enclosed slope < 7' 0 < h < 30 1 -15.5 -18.2 -21.1 -24.3 -27.6 -31.2 -34.9 2 -26.1 -30.6 -35.5 -40.7 -46.3 -52.3 -58.6 3 -39.2 -46.0 -53.4 -61.3 -69.7 -78.7 -88.2 30 < h < 40 1 -16.9 -19.8 -22.9 -26.3 -30.0 -33.8 -37.9 2 -28.3 -33.2 -38.5 -44.2 -50.3 -56.8 -63.7 3 -42.6 -50.0 -58.0 -66.5 -7S.7 -85.5 -95.8 C Open slope < 2.4' unobstructed How 0 < h < 15 1 -15.4 -18.0 -20.9 -24.0 -27.3 -30.9 -34.6 2 -23.5 -27.6 -32.0 -36.8 -41.8 -47.2 -52.9 3 -46.1 -54.1 -62.8 -72.1 -82.0 -92.6 -103.8 15 < h < 20 1 -16.3 -19.1 -22.2 -25.4 -28.9 -32.7 -36.6 2 -24.9 -29.2 -33.9 -38.9 -44.3 -50.0 -56.0 3 -48.8 -57.3 -665 -76.3 -86.8 -98.0 -109.9 20 < h < 30 1 -17.7 -20.8 -24.1 -27.7 -31.5 -3S.6 -39.9 2 -271 -31.8 -36.9 -42.4 -48.2 -54.4 -61.0 3 -53.2 -62.4 -72.4 -83.1 -94.6 -106.7 -119.7 30 < h < 40 1 -18.8 22.1 -25.6 -29.4 -33.4 -37.8 -42.3 2 -28.8 -33.8 -39.2 -45.0 -51.2 -57.8 -64.8 3 -56.4 1 -66.2 -76.8 1 -88.2 1 -100.3 1 -113.3 1 -127.0 Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report 040710.12.13-R2 for FL16709-112 Certificate of Authorization #9503 Revision 2: 03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 2 of 14 ��TRINITYJ ERO Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report C40710.12.13 -R2 for F1.16709 -R2 Certificate of Authorization 119503 Revision 2: 03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 3 of 14 TABIE B (CONTINUED): ROOF liUlD01N5jOF3XN PRESSURES, AUOWA6LE STRES$DESIGN, PASO (PSF) Exposure Enclosure Roof Height (ft) Ultimate Design Wind Speed - V p (mph) Zone 120 130 140 1S0 160 170 180 C Enclosed slope < 7• 0 < h < 15 1 -18.9 -22.1 -25.7 -29.5 -33.5 -37.8 42.4 2 -31.6 -37.1 43.1 -49.4 -56.3 -63.5 -71.2 3 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 15 < h < 20 1 -20.0 -23.4 -27.2 -31.2 -35.5 -40.1 44.9 2 -33.5 -39.3 45.6 -52.3 -59.6 -67.2 -75.4 3 -50.4 -59.2 -68.6 -78.8 -89.6 -101.2 -113.5 20 < h < 30 1 -21.7 -25.5 -29.6 -34.0 -38.7 -43.6 48.9 2 -36.5 -42.8 49.7 -57.0 -64.9 -73.2 -82.1 3 -54.9 -64.4 -74.7 -85.8 -97.6 -110.2 -123.5 30 < h < 40 1 -23.1 -27.1 -31.4 -36.1 -41.0 -46.3 -51.9 2 -38.7 -45.4 -52.7 -60.5 -68.8 -77.7 -87.1 3 -58.3 -68.4 -79.3 -91.0 -103.6 -116.9 -131.1 D Open slope < 2.4• unobstructed flow 0 < h < 15 1 -18.6 -21.9 -25.4 -29.1 -33.1 -37.4 -41.9 2 -28.5 -335 -38.8 -44.5 -50.7 -57.2 -64.1 3 -55.9 -65.6 -76.1 -87.3 -99.4 -112.2 -125.8 15 < h < 20 1 -19.5 -22.9 -26.6 -30.5 -34.7 -39.2 44.0 2 -29.9 -35.1 -40.7 -46.7 -53.1 -60.0 -67.3 3 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.9 20 < h < 30 1 -21.0 -24.6 -28.6 -32.8 -37.3 -42.1 -47.2 2 -32.1 -37.7 -43.7 -50.2 -57.1 -64.4 -72.2 3 -63.0 -73.9 -85.7 -98.4 -111.9 -126.3 -141.6 30 < h < 40 1 -22.1 -25.9 -30.0 -34.5 -39.2 44.3 49.7 2 -33.8 -39.6 -46.0 -52.8 -60.0 -67.8 -76.0 3 -66.2 -77.7 -90.1 -103.5 -117.7 -132.9 -149.0 Enclosed slope < 7• 0 < h < 15 1 -22.9 -26.8 -31.1 -35.7 -40.6 -45.9 -51.4 2 -38.3 45.0 -52.2 -59.9 -68.2 -77.0 -86.3 3 -57.7 -67.7 -78.5 -90.2 -102.6 -115.8 -129.8 15 < h < 20 1 -24.0 -28.1 -32.6 -37.4 -42.6 -48.1 -539 2 -40.2 -47.2 -54.7 -62.8 -71.5 -80.7 -905 3 -60.5 -71.0 -82.4 -94.5 -107.6 -121.4 -136.1 20 < h < 30 1 -25.7 -30.2 -35.0 -40.2 -45.7 -51.6 -57.9 2 -43.2 -50.7 -58.8 -67.5 -76.8 -86.7 -97.2 3 -65.0 -76.3 -88.5 -101.5 -115.5 -130.4 -146.2 30 < h < 40 1 -27.1 -31.8 -36.8 -42.3 -48.1 -54.3 -60.9 2 -45.4 -53.3 -61.8 -71.0 -80.7 -91.1 -102.2 3 -68.4 -80.2 1 -93.0 1 -106.8 1 -121.5 1 -137.2 -153.8 Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report C40710.12.13 -R2 for F1.16709 -R2 Certificate of Authorization 119503 Revision 2: 03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 3 of 14 ��TRINITYJERD TABLE 1: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF); SYSTEM TYPE A: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIDE LAP WIDTH (INCH); X = MAXIMUM SIOE LAP FASTENER SPACING (INCH D.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) Anchor Sheet Base Insulation Top Insulation Roof Cover Attach System Deck MOP At Lap Staggered Center Rows No. (See Note 1) Type Fasteners Type Attach Type Attach Base Ply Cap (Psf) W I X Y I Z SYSTEM DESCRIPTION WITH ZONE 1(FIELD AREA) ANCHOR SHEET ATTACHMENT: W-1 Min. 19/32• inch plywood; See Note 1 Glasbase, All Weather Empire, Plexiglas Base, Po SMS or N Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 3 8 3 8 Min. 1.5 -inch ACFoam II, FlintBoard 150, ENRGY-3, H -Shield or Multi -Max FA3 Hot asphalt, full coverage Min. 0.25 -inch DenSDeck primed with ASTM 041 Primer or OensOeck Prime Hot asphalt, full coverage SP -AA, SBS -AA SBS -TA or APP -TA (Optional) SP -AA, SBS•AA, SBS -TA or APP -TA SBS -AA, SOS -TA or APP -TA •52.5 SYSTEM W-1; ZONE 2 & 3; PERIMETER & CORNER AREA ANCHOR SHEET ATTACHMENT: Ultimate Design Wind Speed - V t (mph) Exposure Enclosure Roo,H'ight Zone 120 130 140 ISO 160 170 180 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<30 3 -Corners 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 30<h<40 3 -Corners 8 3 8 1 8 3 8 7 3 7 7 3 7 7 4 7 6 4 6 7 5 1 7 B 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 1 3 1 8 7 3 7 0<h<30 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 7 5 7 Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 4 7 7 4 7 30<h<40 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 7 5 7 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<15 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 6 4 6 7 5 7 6 5 6 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 15<h<20 3 -Corners 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 6 5 6 6 5 6 C Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 7 3 1 7 20<h<30 3 -Corners 8 3 8 7 3 7 6 3 6 6 4 6 7 5 7 6 5 6 N/A 2 -Perimeters 8 13 8 8 3 8 8 3 8 8 3 8 8 3 8 7 1 3 1 7 8 4 8 30<h<40 3 -Corners 7 3 7 6 3 6 7 1 4 1 7 1 6 4 6 6 1 5 1 6 1 N/A N/A Exterior Research and Design, U.C. d/b/a Trinity l ERD Evaluation Report C40710.12.13 -R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2: 03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 4 of 14 VTRINITYIERD TABLE I (CONTINUED): WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF); SYSTEM TYPE A: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIOE LAP WIDTH (INCH); X = MAXIMUM SIOE LAP FASTENER SPACING (INCH O.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) SYSTEM W-1; ZONE 2 & 3; PERIMETER & CORNER AREA ANCHOR SHEET ATTACHMENT: Ultimate Design Wind Speed — Vw, (mph) Exposure Enclosure RoofHeight Zone 120 130 140 150 160 170 180 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 7 3 7 6 3 6 0<h<15 3 -Corners 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 7 5 7 6 5 6 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 15<h<20 3 -Corners 8 3 8 7 3 7 6 3 1 6 7 4 7 7 5 7 6 5 6 N/A C Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 20<h<30 3 -Corners 7 3 7 7 3 7 7 4 7 6 4 6 6 5 6 N/A N/A 2 -Perimeters 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 30<h<40 3 -Corners 7 3 7 6 3 6 7 4 7 7 5 7 6 5 6 N/A N/A 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 8 4 8 0<h<15 3 -Corners 7 3 7 6 3 6 7 4 7 6 4 6 6 5 6 6 5 6 N/A 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 7 3 7 8 4 8 15<h<20 3.Corners 7 3 7 6 3 6 7 4 7 7 5 7 6 5 6 N/A N/A Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 7 3 7 7 4 7 20<h<30 3 -Corners 7 3 7 7 4 7 6 4 6 6 5 6 N/A N/A N/A 2 -Perimeters 8 3 8 8 3 1 8 8 3 8 1 8 3 8 7 3 7 8 4 8 6 5 8 30<h<40 3 -Corners 6 3 6 7 4 7 6 4 6 6 5 6 N/A N/A N/A 0 2 -Perimeters 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 67 O<h<15 3 -Corners 7 3 7 6 3 6 7 4 7 7 5 7 6 S 6 N/A N/A 2 -Perimeters 8 3 8 8 3 8 7 3 7 7 3 7 7 4 7 7 4 7 15<h<20 3 -Corners 7 3 7 7 4 7 6 4 6 7 5 7 N/A N/A Enclosed 2 -Perimeters 8 3 8 8 3 8 7 3 7 6 3 6 7 4 7 6 4 6 20<h < 30 N/A 3 -Corners 6 3 6 7 4 7 7 5 7 6 5 6 N/A N/A 2 -Perimeters 8 3 8 7 3 7 7 3 7 7 4 7 7 4 7 30< h <40 N/A 3.Corners 6 1 3 1 6 1 7 4 7 7 5 7 6 5 6 N/A Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report C40710.12.13 -R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2: 03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 5 of 14 VTRINITYIERD TABLE 2: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER; SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Top Insulation Layer Roof Cover Base Insulation layer MOP (psf) Type Fasteners Attach Base Ply Cap No. (See Note 1) SYSTEM DESCRIPTION wrrH ZONE 1 (FIELD AREA) INSULATION ATTACHMENT: Min. 19/32 -inch (Optional) One more layers, Min. 1.5 -Inch ACFoam II, ENRGY 3, H- Flintfast 3 in. Insulation Pattern W-2 plywood; See Note 1 n, loose laid any combination, Shield, Multi -Max FA3 or FlintBoard ISO Plates with Flintfast #12 (Optional) t' 1 per 2 ft SBS SA SBS -SA SBS -SA -45.0 primed with FlintPrime SA or #14 INSULATION ATTACHMENT PATTERN REFERENCES: PATTERN #1: PATTERN #2: PATTERN 113: PATTERN #4: PATTERN #S: PATTERN #6: 1 per 2 ft= 1 per 1.4S ft' 1 per 1.33 ft= 1 per 1.14 ft= 1 per 1.00 ft" 1 per 0.84 ft= + +++ Z♦ fiA1 � . + + + + +++++ ... (♦.. .♦ + + ++ + ++++ + + + + + + + + + ®g�D + LL + ++ ++ + + � + + + + + ♦... �. + ++++ —►�`°�r- t } �I>b ��1 t —J.L— -►(>ol♦ f �®ir I ��VZ L_�J__s--I 3Wc --'•�1 -J.If SYSTEM W-2; ZONE 1, 2 & 3; FIELD, PERIMETER & CORNER AREA INSULATION ATTACHMENT: Roof Height Ultimate Design Wind Speed — Vot (mph) Exposure Enclosure (k) Zone 120 130 140 ISO 160 170 180 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #1 #1 #1 0 < h < 30 3 -Corners #1 #1 #2 #2 #4 #5 #5 8 Open 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #1 #1 #2 30 < h < 40 3 -Corners #1 a2 #2 #3 #4 #5 #6 Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report 040710.12.13-112 for FL16709-R2 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 6 of 14 TABLE 2 (1 QOTRINITYIERD .ONTINUED): WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER; SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER SYSTEM W-2; ZONE 1, 2 & 3; FIELo, PERIMETER & CORNER AREA INSuLAnoN ATTACHMENT: Exposure Enclosure Roof Height Ift) Zone 120 130 Ultimate Design Wind Speed — V„ a (mph) 140 ISO 160 170 180 8 Enclosed 0 < h < 30 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #2 #2 #2 3 -Corners #1 #2 #2 #3 #4 #5 #6 30 < h < 40 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #2 #2 #3 3 -Corners #1 #2 #2 #4 #4 #5 #6 Open 0 < h < 15 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #1 #2 #2 3 -Comers #1 #2 #3 #4 #5 #6 N/A 15 < h < 20 1 -Field #1 #1 #1 #1 Ni #1 #1 2 -Perimeters #1 #1 #1 #1 #2 02 #3 3 -Corners #2 #2 #4 #5 #5 #6 N/A 20 < h <,10 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #2 #2 #3 3 -Corners #2 #3 #4 #5 #6 N/A N/A 30 < h < 40 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #2 #2 #3 3 -Corners #2 #4 #5 #6 #6 N/A N/A C Enclosed 0 < h < 15 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #2 #2 #3 #4 3 -Corners #2 #2 #3 #4 115 116 N/A 15 < h < 20 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #2 #2 #2 #4 #4 3 -Corners #2 #2 #4 #5 #6 #6 N/A 20 < h < 30 1 -Field #1 #1 #1 #1 #i #1 #2 2 -Perimeters #1 #1 #2 #2 #3 #4 #5 3 -Corners #2 #3 #4 #5 96 N/A N/A 30 < h < 40 1 -Field #1 #1 #1 #1 91 #2 #2 2 -Perimeters #1 #2 #2 #3 #4 #5 #6 3 -Corners #2 #4 #5 #6 N/A N/A N/A Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report C40710.12.13 -R2 for F1.16709-112 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 7 of 14 TABLE 2 (1 ��TRINITYJERD' :ONTINUED): WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER; SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER SYSTEM W-2; ZONE 1, 2 & 3; FIELD, PERIMETER & CORNER AREA INsutATioN ATTACHMENT: Exposure Enclosure Roof Height (ft) Zone 120 130 Ultimate Design Wind Speed — V,* (mph) 140 ISO 160 170 180 Open 0<h<15 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #1 #2 #2 #3 3 -Corners #2 #4 #4 #6 #6 N/A N/A 1S < h < 20 1 -Field #1 #1 #1 #1 #1 #1 #1 2 -Perimeters #1 #1 #1 #2 #2 #2 #4 3 -Corners #2 #4 #5 #6 N/A N/A N/A 20<h<30 1 -Field #1 #1 #1 #1 #1 41 #2 2 -Perimeters #1 #1 #1 #2 #2 #3 #4 3 Corners #3 #4 #S #6 N/A N/A N/A 30 < h < 40 1 -Field #1 #1 #1 #1 #1 #1 #2 2 -Perimeters #1 #1 #2 #2 #3 #4 #4 3 -Corners #4 #5 #6 N/A N/A N/A N/A D Enclosed 0 < h < 15 1 -Field #1 #1 #1 #1 #1 #2 #2 2 -Perimeters #1 #1 #2 #2 #4 #5 #5 3 -Corners #2 #4 #5 #6 #6 N/A N/A 15 < h < 20 1 -Field #1 #1 #1 #1 #1 #2 #2 2 -Perimeters #1 #2 #2 #3 #4 #5 #6 3 -Corners #3 114 #5 #6 N/A N/A N/A 20 < h < 30 1 -Field #1 #1 #1 #1 #2 #2 #2 2 -Perimeters #1 #2 #2 #4 #5 #5 #6 3 -Corners #3 #5 #6 #6 N/A N/A N/A 30 < h < 40 1 -Field #1 #1 #1 #1 #2 #2 2 -Perimeters #2 #2 #3 #4 #5 #6 3 -Corners #4 #5 #6 N/A N/A N/A N/A Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report 040710.12.13-R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2: 03/11/2015 Prepared by: Robert Neeminen, PE -59166 Appendix 1, Page 8 of 14 QOTRINITYIERD TABLE 3: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER; SYSTEM TYPE D: INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIDE LAP WIDTH (INCH); X = MAXIMUM SIDE LAP FASTENER SPACING (INCH D.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) Insulation Layer(s) Base or Anchor Sheet Roof Cover Attach System Deck MOP At Lap Staggered Center ROWS(s) No. (See Note 11 Type Attach Base Fasteners Ply Cap (psf) W x Y z SYSTEM DESCRIPTION WITH ZONE 1(FIELD AREA) BASE SHEET ATTACHMENT: W-3 Min. 15/32- inch plywood; See Note 1 Min. 1.5 -inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20, Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates With Flintfast #12 or #14 4 6 3 6 (Optional) BP -AA, SBS -AA, SBS -TA or APP -TA SBS -AA, SBS -TA or APP -TA -97.5 SYSTEM W-3; ZONE 2 & 3; PERIMETER & CORNER AREA BASE SHEET ATTACHMENT: Ultimate Design Wind Speed — V„h (mph) Exposure Enclosure Roof Hight (ft2-Perimeters Zone 120 130 140 150 160 170 180 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 0<h<30 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 Open 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 30<h<40 3 -Corners 6 3 6 6 3 6 6 3 66 3 6 6 3 6 6 3 6 6 3 6 B 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 0<h<30 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6' Enclosed 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 30<h<40 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 0<h<15 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 15<h<20 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 C Open 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 20<h<30 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 30<h<40 3 -Comers 6 3 6 6 1 3 _Lj 6 3 6 1 6 3 6 7 1 4 1 7 6 1 4 6 6 4 6 Exterior Research and Design, I.I.C. d/b/a Trinity(ERD Evaluation Report 040710.12.13-112 for FL16709-R2 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Niemmen, PE -59166 Appendix 1, Page 9 of 14 QININ I ERD TABLE 3 (CONTINUED): WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER; SYSTEM TYPE D: INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIDE UIP WIDTH (INCH); X = MAXIMUM SIOE LAP FASTENER SPACING (INCH D.C.); Y = MINIMUM N OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) SYSTEM W-3; ZONE 2 & 3; PERIMETER & CORNER AREA BASE SHEET ATTACHMENT: Ultimate Design Wind Speed — VA (mph) Exposure Enclosure Roof Hight Zone 120 130 140 ISO 160 170 ISO X Y Z X Y 2 X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 0<h<15 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 15<h<20 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 1 7 4 7 6 4 6 C Enclosed 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 20<h<30 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 30<h<40 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 7 5 7 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 0<h<15 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 15<h<20 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 7 5 7 Open 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 20<h<30 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 6 5 1 6- 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 30<h<40 3 -Corners 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 6 4 6 6 5 6 0 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 0<h<15 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 6 4 6 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 1 6 3 6 15<h<20 3 -Corners 6 3 6 6 3 6 6 3 6 6 3 6 6 4 6 6 4 6 6 5 6 Enclosed 2 -Perimeters 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 20<h<30 3 -Corners 6 3 6 6 3 6 6 3 6 7 4 7 6 4 6 6 4 6 6 5 6 6 6 3 6 6 3 6 6 3 6 6 3 6 6 3 6 7 4 7 30<h<40 ff2-!erimetters36 3 -Corners 6 3 6 6 3 6 6 3 6 6 4 6 6 4 6 6 S 1 6 1 6 5 6 — Exterior Research and Design, I.I.C. d/b/a Trinity l ERD Evaluation Report C40710.12.13 -R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 10 of 14 ��TRINITYJERD TABLE 4: WOOD DECKS — NEW CONSTRUCTION OR REROOF TEAR -OFF; SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIDE LAP WIDTH (INCH; X = MAXIMUM SIDE LAP FASTENER SPACING (INCH O.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.( Base Sheet Roof Cover Base Fasteners Attachment Pty Cap System No. Deck (See Note l) MOP (psf) At Lap Staggered Center Row(s) W X Y Z SYSTEM DESCRIPTION WITH ZONE 1(FIE10 AREA) BASE SHEET ATTACHMENT: W -4 Min. 19/32 -inch plywood; See Note 1 Flintlastic SA NailBase 32 ga.,1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 2 8 3 8 (Optional) SBS - SA SBS -SA -600 SYSTEM W-4; ZONE 2 & 3; PERIMETER & CORNER AREA BASE SHEET ATTACHMENT: Ultimate Design Wind Speed — V,* (mph) Exposure Enclosure Roof Hight Zone 120 130 140 ISO 160 170 180 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<30 3 -Corners 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 5 4 5 Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 30<h<40 3 -Corners 8 3 8 8 3 8 8 3 1 8 7 3 7 7 3 7 5 4 5 5 4 5 B 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<30 3 -Corners 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 5 3 5 4 3 4 Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 30<h<40 3 -Corners 8 3 8 8 3 8 8 3 8 7 3 7 5 3 5 4 3 4 4 3 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 O<h<IS 3 -Corners 8 3 8 8 3 8 8 3 8 7 3 7 5 4 1 5 5 4 5 5 5 S 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 15<h<20 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 5 4 5 5 4 5 5 5 5 C Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 20<h<30 3 -Corners 8 3 8 1 7 3 7 7 3 7 5 4 5 5 4 5 5 5 5 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 6 3 6 30<h<40 3 Corners 8 3 8 7 3 7 6 3 6 5 4 5 5 5 5 4 5 4 4 S 4 — Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report 040710.12.13-R2 for F1.16709-112 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 11 of 14 QOTRINITYIERD TABLE 4 (CONTINUED): WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF); SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIOE LAP WIDTH (INCH); X = MAXIMUM SIDE LAP FASTENER SPACING (INCH D.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) SYSTEM W-4; ZONE 2 & 3; PERIMETER & CORNER AREA BASE SHEET ATTACHMENT: Ultimate Design Wind Speed — V, k (mph) Exposure Enclosure Roof �Htl ight Zone 120 130 140 ISO 160 170 ISO X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 0<h<1S 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 4 3 4 4 3 4 4 4 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 5 3 5 15<h<20 3 -Corners 8 3 8 8 3 8 7 3 7 5 3 5 1 4 3 4 4 3 4 4 4 4 C Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 7 3 7 S 3 5 20<h<30 3 -Corners 8 3 8 7 3 7 6 3 6 4 3 4 4 3 4 4 4 4 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 5 3 5 4 3 4 30<h<40 3 -Corners 8 3 8 7 3 7 S 3 5 4 3 4 4 4 4 4 4 4 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 6 3 6 0<h<15 3 -Corners 8 3 8 7 3 7 6 3 6 S 4 5 5 5 5 4 5 4 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 S 1 3 5 15<h<20 3 -Corners 8 3 8 7 3 7 6 4 6 S 4 5 5 5 5 4 S 4 4 5 4 Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 6 3 6 6 4 6 20<h<30 3 -Corners 8 3 8 6 3 6 S 4 5 S 4 S 5 5 S 4 5 4 4 5 4. 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 4 7 6 4 6 30<h<40 3 -Corners 7 3 7 6 4 6 S 4 5 5 S S 4 S 4 4 5 4 4 6 4 0 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 S 3 S 4 3 4 0<h<1S 3 -Corners 8 3 8 7 3 7 5 3 5 4 3 4 4 3 4 4 4 4 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 4 3 4 4 3 4 15<h<20 3 -Comers 8 3 8 7 3 7 6 3 6 S 3 5 4 4 4 4 S 4 4 5 4 Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 7 3 7 5 3 5 4 3 4 4 3 4 20<h<30 3 -Corners 7 3 7 5 3 S 4 3 4 4 3 4 4 4 4 4 5 4 4 6 4 2 -Perimeters 8 1 3 8 8 3 8 8 3 8 7 3 7 4 3 4 4 3 4 30 < h < 40 1 1 N/A 3 -Corners 1 7 1 3 1 7 1 4 1 3 1 4 1 4 1 3 4 4 4 4 4 S 4 4 5 4 Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report C40710.12.13 -R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 12 of 14 QOTRINITYIERD' TABLE 5: WOOD DECKS — NEW CONSTRUCTION OR REROOF TEAR -OFF); SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIDE LAP WIDTH (INCH); X = MAXIMUM SIOE LAP FASTENER SPACING (INCH D.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) Base Sheet Roof Cover Base Fasteners At Lap Attachment Staggered Center Row(s) Ply Cap System No. Deck (See Note 11 MDP (psF) W X Y Z SYSTEM DESCRIPTION WITH ZONE 1 (FIELD AREA) BASE SHEET ATTACHMENT: W-5 Min. 19/32 -inch plywood; See Note 1 Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1 -5/8 -inch dia. tin caps with 11 ga. annular ring shank nails 4 8 3 8 SP -AA, SBS -AA, SBS -TA or APP- TA 585 -AA, 585 -TA or APP -TA -60.0 SYSTEM W -S; ZONE 2 & 3; PERIMETER & CORNER AREA BASE SHEET ATTACHMENT: Ultimate Design Wind Speed — V.% (mph) Exposure Enclosure RoofHeight Zone 120 130 140 ISO 160 170 180 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<30 3 -Corners 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 5 4 5 Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 30<h<40 3 -Corners 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 S 3 5 S 4 5 8 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<30 3 -Corners 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 6 3 6 4 3 4 Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 30<h<40 3 -Corners 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 4 3 4 4 3 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 0<h<15 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 5 3 5 5 4 5 4 4 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 15<h<20 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 5 4 5 5 4 5 4 5 4 C Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 20<h<30 3 -Corners 8 3 1 8 7 3 7 6 3 6 5 3 5 S 4 5 5 5 5 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 1 8 3 8 8 3 8 1 8 3 1 8 1 7 1 3 7 30 < h < 40 3 -Corners 8 3 8 7 3 7 6 3 6 1 5 4 5 5 5 5 4 5 1 4 1 4 1 5 td Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report C40710.12.13 -R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 13 of 14 ��TRINITYJERD TABLE 5 (CONTINUED): WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF); SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOMENCLATURE: W = MINIMUM SIDE LAP WIDTH (INCH); X = MAXIMUM SIOE LAP FASTENER SPACING (INCH O.C.); Y = MINIMUM # OF STAGGERED CENTER ROWS; Z = MAXIMUM CENTER ROW FASTENER SPACING (INCH O.C.) SYSTEM W -S; ZONE 2 & 3; PERIMETER & CORNER AREA BASE SHEET ATTACHMENT: Ultimate Design Wind Speed - V„ft (mph) Exposure Enclosure RooHeight Zone 120 130 140 150 160 170 180 X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 O<h<15 3 -Corners 8 3 8 8 3 8 7 3 7 6 3 6 5 3 S 4 3 4 4 4 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 15<h<20 3 -Comers 8 3 8 8 3 1 8 7 3 7 6 3 6 4 3 4 4 3 4 4 4 4 C Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 7 3 7 6 3 6 20<h<30 3 -Corners 8 3 8 7 3 7 6 3 6 5 3 5 4 3 4 4 4 4 4 S 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 5 3 5 30<h<40 3 -Corners 8 3 8 7 3 7 6 3 6 4 3 4 4 3 4 4 4 4 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 O<h<15 3 -Corners 8 3 8 7 3 7 6 3 6 5 4 S 5 4 5 4 5 4 4 5 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 15<h<20 3 -Corners 8 3 8 7 3 7 6 3 6 5 4 5 S 5 S 4 S 4 4 6 4 Open 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 4 6 20<h<30 3 -Corners 7 3 7 6 3 6 5 4 S 5 4 S 5 6 S 4 6 4 4 6 4 2 -Perimeters 8 3 8 8 3 1 8 1 8 3 8 8 3 8 8 3 8 7 4 7 6 4 6 30<h<40 3 -Corners 7 3 7 6 3 6 5 4 5 4 4 4 4 5 4 4 6 4 N/A D 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 5 3 5- 0<h<15 3 -Corners 8 3 8 7 3 7 6 3 6 4 3 4 4 3 4 4 4 4 4 S 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 4 3 4 15<h<20 3 -Corners 8 3 8 7 3 7 6 3 6 S 3 S 4 4 4 4 S 4 4 5 4 Enclosed 2 -Perimeters 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 5 3 5 4 3 4 20<h<30 3 -Corners 7 3 7 6 3 6 4 3 4 4 3 4 4 4 4 4 S 4 4 6 4 2 -Perimeters 8 3 8 8 3 8 8 3 8 7 3 7 6 3 6 4 3 4 30 < h < 40 N/A 3 -Corners 7 3 1 7 1 6 3 6 4 1 3 4 4 4 4 4 5 4 4 5 4 Exterior Research and Design, U.C. d/b/a TrinityjERD Evaluation Report 040710.12.13-R2 for FL16709-R2 Certificate of Authorization #9503 Revision 2:03/11/2015 Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 14 of 14 7/29/2015 Florida Building Code Online Business • Professional Regulation r f1Vfoa pepaMrpMd SCIS Home I Log In I User Registration ' Hol Topcs Submlt Surcharge Stats It Facts Publications FBC Staff SCIS Site Map Links Search Profess% dal ®Product Approval USER: Public User Regulation Product Aooreval Menu > Product or Acolication Search > Aoohat,on List > Application Detail ITHE FL # FL10674-R10 SECRETARY Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Robert J.M. Nieminen PE -59166 UL LLC 08/20/2017 John W. Knezevich, PE Validation Checklist - Hardcopy Received Standard ASTM D3161 ASTM D3462 ASTM D7158 Year 2009 2009 2008 http://www.floridabuilding.orglpr/pr_app M.aspx?pwam=wGEVXQwtDgtBNbEY5WoZwQT%Z*w7ahReglCO8ucR6ixEAoiMeKNJKxMw%3d%3d 1/2 7/29/2015 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ: Yes SHINGLES FL10674-1110.Odf Impact Resistant: N/A Verified By: Robert 3. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section S. Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES FL10674-R10.Ddf Created by Independent Third Party: Yes BaIM Nett Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone, 850.487.1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement • • Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mad to this entity. Instead, contact the office by phone or by traditional mad. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine it you are a licensee under Chapter 455, F.S., please click here_. Product Approval Accepts: ® ® FM CreditSAFE Illtp://www.11oridabuilding.org/pr/pr_appM.aspx?param=wGEVXQwtDgtBNbEYSV%�oQT%2b6w7ahReglCO&xR6ixF�biMeKNJKnMw%3d%3d 2/2 QOTRINITYIERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate oJAuthorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Owens Corning Evaluation Report 037940.02.12-R5 One Owens Corning Parkway FL10674-R10 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 5: 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/22/2015. This does not serve as an electronically signed document Signed. sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. QOTRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2 6.1 Wind Resistance ASTM D3162 2009 1507.2.7.1, R905.2.6.1 wind Resistance ASTM D7258 2008 3. REFERENCES: iniibf Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire'" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration*, TruDefinition Duration*, Duration* Premium Cool, TruDefinition* Duration* Designer Color Collection, TruDefinition Oakridge, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. 1JIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to V,:d = 150 mph (V„ h = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to V.,d = 150 mph (V„ h = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12 -RS certificate of Authorization #9S03 FL10674-R10 Revision S: 04/22/201S Page 2 of 6 1� l 1 RINIIY I ERD 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: i Berkshire shingles require minimum five (5) nails per shingle. 9 WeatherGuard* HP shingles require minimum six (6) nails per shingle. D Devonshire'" shingles require minimum six (6) nails per shingle. 9 Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic° & Supreme: tl� Ames M Mansard na d�iraw y Area pan Wwrtos normaM Arws vhmtoa har"s 11 21 .. 5'Exposuh Espealtfdn 6.2.6 Minimum Nailing — Berkshire•: Exterior Research and Design, I.I.C. Certificate oJAuthorirotion #9503 Normal Mansard or Area pars IMnd Areas High NRnd dosvanas y Area pare vim"" norma/as Areas 11,10mas /wms 5 W8' Exposuh Exposlcl6n boabnlsnip b 16s dr stidn f 8W 0 V 8W 8W 1' 1 r Asphak roolin8o/lnlat CoWto dr 1whodr etab Evaluation Report 037940.02.12 -RS FL10674-R30 Revision S: 04/22/2015 Page 3 of 6 QOTRINITYIERD 6.2.7 Minimum Nailing—Devonshire": o a r 7 —� 1ws r r ♦ • r r r r r r yw w• q� {III' v sw W i ... ►v Nails Ten I'Spw of Asphalt Roof Cemem 6.2.8 Minimum Nailing — Duration•, TruDefinition• Duration, Duration• Premium Cool & TruDefinition' Duration Designer Color Collection: 4 Nab PAsm Esgtrama do 4 dwas SuSal wwtA Arra d. dalof so r 1• 1' 6Va" E:pbww Nabi W Bila e bis poly. d azavrlalbn abow W pulp. do mposiclM L 7 n nA:-:..-..— LI..:1:.-� _ T...fI..R�:�:��'/1..L.:J....O f1..L.:J....•. 4 Nall Patton Esquama can 4 davos r r It— >r --il Imo— 1r —l•I 6 Sff & basun W6s 6 Sir Exposu! 6ryoddbsda66/4PdG Cbr o Ea�edddndr66/4pd¢ 6.2.10 Minimum Nailina — WeatherGuard• HP: Lrmromdcbresbapp�� 6 Nall lobo btn• tunN>M Pattern 7Mnnolad""Oks. do6deves aSwaka o"a • • • ep+ofu�M>war..Vr•.LL funpl� � � La♦4U► 0abtln➢ OanVn >t•wlmA >ro•�n Aloe. r Lo �jN 1r ^ /T _ $w al► SW Expasuro Naa 5w Epoftuo W pdy. da arp *Vn aav a PA prto. do aapostd4n 6 Nall Paftm Esquema wn 6 dams 1111111flealb �dVUat :� fRstirs7bwtrf Msll itb arisr�riri�sdb Exterior Research and Design, LLC. Evaluation Report 037940.02.12 -RS Certificate of Authorization #9S03 FL10674-R10 Revision S: 04/22/2015 Page 4 of 6 r r wNab OIL", 25 6618" Bgwwo Ckwoes 6 SW Eq•sttw BrD=Wnd#66/ypd9 Expmlaldnda 661#pufa 1111111flealb �dVUat :� fRstirs7bwtrf Msll itb arisr�riri�sdb Exterior Research and Design, LLC. Evaluation Report 037940.02.12 -RS Certificate of Authorization #9S03 FL10674-R10 Revision S: 04/22/2015 Page 4 of 6 ��TRINITYJERD 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire' Hip & Ridge and High Ridge: 6.3.4 Minimum Nailing — Hip & Ridge with Sealant: Fig. 2 TopV11W SiOovisr Mip1 M r — Top Lunka d r T 1- AMD T 1 1 i I 1 r �I i 1 I I I F:n[m �' ind a aafty Shingle Discard2"xcess 1" 1" SSttrip T 12" Fastening 515/a' 5"Exposure Distance 12" 6.3.5 Minimum Nailing — WeatherGuard° HP Hip and Ridge: Fig. C Hip & Ridge Shingle Fastening Top Vbw mi11 Elks r r r r t• 1 it —►I Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R5 Certificate of Authorization #9503 FL10674-R10 Revision S: 04/22/2015 Page 5 of 6 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wand Direction s h." A--' 6' wmm - Fastoa Tb• Fas�ta Roof Gnat _ rTRINITYIERD Standard t f•—� Fastening Pattern 12S"km 7'h• B.t I•-12'—� 6.3.7 Minimum Nailing - DuraRidge'" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. ~ Dind'euWbdolmim dm*nK&dur=t (linmEn dd d nm pr danlooat• Ndb ' • i i LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. QUALITY ASSURANCE ENTITY: UL LLC- QUA9625; (414) 248-6409; karen.buchmann(Mul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12 -RS Certificate o/Authoriration u9S03 FL10674-R10 Revision S: 04/22/2015 Page 6 of 6 Toy View f 2'I�� 0. �"• • t OwsCar�V 9rNlal • I I ch �. a IMIM V I LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. QUALITY ASSURANCE ENTITY: UL LLC- QUA9625; (414) 248-6409; karen.buchmann(Mul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12 -RS Certificate o/Authoriration u9S03 FL10674-R10 Revision S: 04/22/2015 Page 6 of 6 CITY OF SANFORD BUILDING SERVICES Residential Re -Roof Hurricane Mitigation Inspection Affidavit PP.Tmit 1, ROBERT DONOVAN hereby acknowledge that 1 personally inspected oof deck nailing and/or Secondary water barrier work at JIM W. I bth 56. 5Q0Gjn3 I F.?=—j-3 I _ and have determined that the work (Job Site Address) was done according to the Hurricane Mitigation Retrofit Manual. (based on 553.844 F.S.) I certify that my statements herein are true and accurate to the best of my belief and that I fully understand that making any false statements in writing with the intent to mislead a public servant in the performance of his or her official d shall constitute a misdemeanor of the second degree pursuant to Section 837.06 F.S. - %�l Signature of Contractor Date 1biwl �aYl Printed flame of Contractor License License "type: 0 General 0 Building 0 Residentia, Roofing Contractor 0 or any individual certified in accordance with F.S. 68 to make such an inspection. STATE OF FLORIDA COUNTY OF SEMINOLE Sworn to (or affirmed) and subscribed before me this _g,," day of C�- , 20 14', by ROBERT DONOVAN , who is IR Personally Known to me o has 0 Produced (type of identification) as identification. (SEAL) Signature try Public St e f lor' Prin y S mp Name of Notary Public LUZK LOPEZ MY COMMINION A Pi 949092 ��#: EXPIf785: JAAWIfy 10, 292(1 �'F•�v�oa� Bonbed 1hm BUW Noteey toYb e 3