HomeMy WebLinkAbout310 Sunrista CtCITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No:
Documented Construction Value: S LA
Job Address: Io e 1)nyI slTA V- Ilistoric District: Yes ❑ No ❑
Parcel 1D: J0.2(b ► ';;b -510. 0 000 - Mot O Residential R3 Commercial ❑
Type of Work: New ❑ Addition ❑ Alteration ® Repair ❑ Demo ❑ Change of Use ❑ Move ❑
Description -of Work: REPLACE Pbt1A GOO( Z\ZQ. �& 4&
Plan Review Contact Person: MEGAN CONSTABLE
Phone: 352-3MM-3360
Title: AGENT
Faxt. 352-861-7587 Email. PERMITSPLUSLLC@GMAIL.COM
Property Owner Information
Name )zcc �e n QCbe_(s Phone: 1403 _ 2-A6 - 61
•Street: ,2>1 0 U Resident of property? rty?
�� . YES
City, State Zip: ISI '�Ja�1�1�
Contractor information
Name LOWES - PETER A CAFARO Phone: 352 -MO -3360
Street: PO BOX 781933 Fax:861-7587
City, State Zip: ORLANDO. FL 32878
Name: NIA
Street:
City, St, Zip:
Bonding Company:
Addeess:
NIA
State.License No.:
ArchitectlEngineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
CGC1508417
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY: A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND'POSTED ON -THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, C04XSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance ora permit and that -all work will be performed to mat standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work. plumbing, signs, wells, pools,
furnaces; boilers, heaters, looks, and air coaditioners, etc.
FOC 1053 Sboll be inscribed witb the date otappliestioo and the code In effect as ortbat date: Sp Edition (2014) Florida Building Code
Revised: June 30. 2015 Permir AppliMion /IPA 1
NOTICE : In addition to the morements or this permit. dare may be Wditiotnl restrictions applicable a this property dot may be
found in the public teoords of dds county. and there may be additional permits required from other Vveromentel entities such a water
aarapment disaicts. state agencies, or federal ageacies.
Acceptance of permit is vrcrifiatiom that I will notify the owner orthe property of the requirements or Florida Uen Law. FS 713.
The City of Sanford requires payment of a plan review fee at the time of peril submittal. A copy of the executed contract is required
in order to cakub to a plan review charge and will be considered the estimated oansvuc ion valve of the job at the time of submittal.
The actual eonuntetion value will be figured based an the current ICC Vohatioo Table in effect at the time the permit is bsued, in
accordance with local ordinance. Should aleuilated charges figured off the executed contract aoeeed the actual eonsuuetiom value.
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify tial all of the foregoing information Is accurate and that all work will
be dome in compliance with all applicable laws regulating construction and zoning.
SWmme6r0rtnWA9 W One
Preen t W=0Aaau's Nona
slo mmor"emy4wer"Wwa Ons
Owner/Agem is Personally Known to Me or
Pt Wuoed ID Type of ID
SrpiannefC oNAReaI Ogee
MEGAN CUNSTABLE
Prole
CHRISTY M GALAS
MY COMMISSION #FF049697
EXPIRES September 29, 2017
398.0153 FloridallotaryService.com
Contractor/Agent is _J& Personally Known to Me or
Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building [3 Electrical ❑ Mechanical ❑ Plumbing0 Gas❑ Roof
Construction Type: Occupancy Use: Flood Zone:
Total Sq Ft of Bldg: Min. Occupancy Load: 0 of Stories:
Now Comstruetlon: Meech is - g of Amps Plumbing - g of Axtutres
Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No ❑
APPROVALS: ZONING: UTILITIES: WASTE WATER:
ENGINEERING: FIRE: BUILDING: 5r 5-Z3- K -
COMMENTS:
R"mad: lust 30.2015 Panty Appbadn
REQUIRED INSPECTION SEQUENCE
BP# 1( 14% 4
` Ber"ING PERMIT
min Mal Inspection Description
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Pre our
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Frame
Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Jew Final Door
Final Window
Final Screen Room
Final Pool Screen Enclosure
Mobile Home Building Final
Pre -Demo
Final Demo
Final Single Family Residence
Final Building Other
REVISED: June 2014
IELECTRICAL L IP'ERMIT
1Vl[in I Max I Inspection Description
Electric Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
7in Max Inspection Description
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
MECHANICAL PEItNItT
min Max- Inspection Description
Mechanical Rough
Mechanical Final
1Vllin Marc Inspection Description
Gas Underground
Gas Rough
Gas Final
Propefy Record Caro
Parcel: 10.2030-5100000.0090
Owner. ROBERTS KATHLEEN C
ao�oraoounrno�x Property Address: 310 SUNVISTA CT SANFORD. FL 32773-7422
Parcel Information I I Value Summary
Parcel 1020.3051000000090
Owner ROBERTS KATHLEEN C
Property Address 310 SUNVISTA CT SANFORD, FL 327737422
Mailing 310 SUNVISTA CT SANFORD, FL 327737422
Subdivision Name SUNVISTA
Tau District S1-SANFORD
DOR Use Code 01SINGLE FAMILY
Exemptions 00HOMESTEAD(1995)
Legal Description
LOT 9
SUNVISTA
PB 45 PG 100
Taxes
Tax Amount without SOH: $322.00
2015 Tax Bill Amount $171.00
Tex Estimator
Save Our Homes Savings: $151.00
Does NOT INCLUDE Non Ad Valorem Assessments
Taxing Authority
2016 Working
Valdes
2015 Certllled
Values
Valuation Method
Cost/Market
Cost/Merket
Number of Buildings
1
1
Depredated Bldg Value
$43,062
$35,120
Depreciated EXFT Veale
$1,151
$1,201
Lard Value (Market)
$15,000
$10,000
Lard Value Ag
$11,304
County Bonds
JusUMarkel Value ••
$59,233
$46,321
Portability Adj
Save Our Homes Adj
522,429
$9,773
Amendment 1 Adj
P&G Adj
$0
50
Assessed Value
$36,804
536,548
Tax Amount without SOH: $322.00
2015 Tax Bill Amount $171.00
Tex Estimator
Save Our Homes Savings: $151.00
Does NOT INCLUDE Non Ad Valorem Assessments
Taxing Authority
Assessment Value Exempt Values
Taxable Value
Page
County General Fund
$36,804
$36,604
$0
Schools
$36,804
$25,500
$11,304
City Sanford
$36,804
$25,500
$11,304
SJWM(Selnt Johns Water Management)
$36,804
$25,500
$11,304
County Bonds
536,804
$25,500 1
$11,304
Sales
Description
I Daft
Book
Page
Amount Quali0ed
Vadlmp
WARRANTY DEED
6/1/1994
1 02782
LZ
$60.900 Yes
Improved
QUIT CLAIM DEED
1/1/1993
1 02531
$45,000 No
Vacant
Find Comparable Sala
Land
Method Frontage Depth Units Units PrkeLand Value
LOT 0.001 0.00 1 $15,000.00 1 $15,000
Building Information
IMPROVING HOME IMPROVEMENT
P. O. Box 781993
Orlando, Florida 32878
Phone: (407) 393-9161 Facsimile: (407) 407-393-9151
Limited Power of Attorney
Date: S )
To: Building Dept.
From: Peter Anthony Cafaro III
I hereby name and appoint, Megan Constable, Gregory Galas, Naomi Mason, Anne Romano, Donna
Malvar, Joshua Galas, Alivia Terriaca, Michaela Spena, Phillip Romano, or Sabrina Sierens, a permit
service for Lowes Home Centers, to be my lawful attorney in fact to act for me to register my license and
apply to:
�'Zn ARGZA_for a A o ,i permit for work to be performed at:
Lot: Blk• Sec: ' d Twp: 2a Rge•
Subdivision: Q n %A S+ja Parcel or Altkey: ID to
Address of Job: CA U 43Un�-,M U 'f
Owner of Property: r
and to sign and do all th' ecessary to this appointment.
Thank you for your ce.
Sincerely,
'Anthony Cafaro III
ary State Qualifier
1508417
State of Florida
County of Orange
The foregoing instrument was acknowledged before me by Peter Anthony Cafaro III, who is personally known to me and
who did not take an oath.
Sworn to and sub ed b me this day of �Q �� 2016.
Notary Pub' VX
My Co ires: 10/21/2016 ,o;a���s`.: CHRISTY M GALAS [S�1
€ MY COMMISSION IFF049697
EXPIRES September 29. 2017
(:0713980153 FioridONolarySO"Icc.com
673406: SOS: MAS PANEL SM FG PAINT: ENTRY/EXTERIOR, SINGLE UNIT, 6 PANEL " 15%
ENTRY DOORS " 05/05/16 - 05/16/16: DOOR FABRICATION SERVICES INC - CITY 1
INSTALLATION DESCRIPTION
Stock or SOS: Stock
Select Location : Front Door
Hardwood (Mahogany or Oak) Door: No
Hidden Damage Description. None
Install Specialized Mortise Hardware: No
Total Linear Feet of Custom Trim to be Installed: 0
Customer Understands Scope of the Project: Yes
Who Will Obtain Permit: Third Parry
Additional Miles Traveled over 20: 0
Bring Up To Code Charge: Yes
Describe Other Work Needed: Build out under sill
Comments: customer is responsible for any screw holes and any touchups
STORE COPY
AIL ON ALL MASONITE SPECIAL ORDER
Materials Price 1 $ 747.
Door Type: Exterior
Select New Door: Single Pre -hung
Side Lights or Transoms: No
Number of additional holes bored for accessories: None
Install Storm Door: No
Deliver Door: Yes
Permit Required: Yes
Permit Fee: Yes
Bring Up To Code Description : install bucks
Local Disposal Fee: Yes
Other Work Charge: Yes
Lead Safe Practices: No
Labor Charges $ 631
Detail Deduction -$ 35
Additional Specifications:
Notation: Lowe's will not make structural modifications, paint or stain or removelreinstall security system equipment. Customer is responsible to advise if prop-
erty is governed by Historic District Regulations.
Additional Specifications: Federal law requires Lowe's to provide you with the pamphlet Renovate Right: Important Lead Hazard Information for Familes,
Child Care Providers and Schools. By signing this Contract, Customer acknowledges having received a copy of this pamphlet before work began informing
Customer of the potential risk of the lead hazard exposure from renovation activity to be performed in Customers dwelling unit.
PHOTO RELEASE: Customer grants to Lowe's and Lowe's employees and independent contractors the right to take photograghs of the Premises where In-
stallation Services will be performed and all work performed at the Premises related to this Contract, and irrevocably grants to Lowe's all right, title, interest in
and to the photographs for use in all markets and media, worldwide, in perpetuity. Customer authorizes Lowe's to copyright, use and publish the photographs in
print and/or electronically, and agrees that Lowe's may use such photographs for any lawful purpose, including, but not limited to, marketing, advertising, publi-
city, illustration, training and Web content. By initialing here. Customer agrees to the foregoing. [Customer to initial to the left].
NOTICE TO CUSTOMER - PRICE CALCULATIONS: In order to properly perform the installation of certain Goods, the Contract Price may include more
Goods than actually will be installed based on the measured square footage of the Project Area. As a result, the parties agree that the lump -sum Price stated in
Store 1657 Project No. 474097043 for KATHLEEN ROBERTS Page 2 of 7
J•
v,
0
V
v
w
r�
oM
M
�d
0
01
No cmn
V
V
o
N
CD
W
Cn
CD
a
a
3
v
w
%0
STORE COPY
this Contract is calculated upon both the value of the estimated Goods required to fulfill the Contract (including waste), which may exceed the actual square
footage of the Project Area, and the labor which may be estimated based on the amount of Goods required to fulfill the contract (including waste). By signing
this Contract below, Customer acknowledges receipt of this notice and agrees and understands that the Price includes these costs which may not be refunded
once the Installation Services are performed..
NOTICE OF ARBITRATION AGREEMENT
This Contract provides that all claims by Customer or Lowe's will be resolved by BINDING ARBITRATION. Customer and Lowe's GIVE UP THE RIGHT TO GO
TO COURT to enforce this Contract (EXCEPT for matters that may be taken to SMALL CLAIMS COURT). Lowe's and Customer's rights will be determined by
a NEUTRAL ARBITRATOR and NOT a judge or jury. Lowe's and Customer are entitled to a FAIR HEARING. But the arbitration procedures are SIMPLER AND
MORE LIMITED THAN RULES APPLICABLE IN COURT. Arbitrator decisions are as enforceable as any court order and are subject to VERY LIMITED RE-
VIEW BY A COURT. FOR MORE DETAILS: Review the section titled ARBITRATION AGREEMENT, WAIVER OF JURY TRIAL AND WAIVER OF CLASS AC-
TION ADJUDICATION found in the Terms and Conditions of this Contract.
I TOTAL CHARGES OF ALL MERCHANDISE AND SERVICES [where applicable I
SUB -TOTAL $1243.931
DELIVERY $ 0.0
ORDER TOTAL $1243.
BALANCE DUE
Work is to commence upon reasonableaav'ailabGry of Contractor which is anticipated to be 3d fill in date].
Estimated completion date is LE
v (fill in date].
NOTICE TO CUSTOMER
All items listed in this contract and specification sheet(s) are to be installed under conditions agreed upon at time of purchase and at the price appearing
on this contract form. This assumes sound existing substructures, superstructure and points of attachments. Extra labor or material incident to installation
necessitated by defective substructures, superstructure, points of attachment, or the moving of fixtures or appliances to be billed at extra cost to custom-
er. DO NOT SIGN THIS CONTRACT UNTIL COMPLETE AND YOU HAVE READ THE TERMS AND CONDITIONS OF THIS CONTRACT. BY SIGNING
BELOW, YOU ARE ACKNOWLEDGING THAT YOU HAVE READ, UNDERSTAND AND AGREE TO THE TERMS AND CONDITIONS SET FORTH ON
THIS CONTRACT. YOU ARE ENTITLED TO A COPY OF THIS CONTRACT AT THE TIME OF SIGNATURE.
NOTICE TO OWNER: -ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001- 713.37, FLORIDA
STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT
PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS
KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCON-
TRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY
Store 1657 Project No. 474097043 for KATHLEEN ROBERTS Page 3 of 7
N
o
o�
0
T
r
r
0%
M
%0
M
r�
M
m
v
STORE COPY
rV V.. 1V .VV....IV. r.... —woo ■VV 5.I9.1- Plr..rP'IV. r."I.V .VV.I VV.\I"r%f I VII .I\ . V". I.-
YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS
MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERI-
ALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO
PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR
CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COM-
PANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX,
AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY.-`
WITNESS OUR NO(S) AND SEAL(S) BELOW THIS116DAY OF �'1, 0�i6
Address
S�AF�oi oc� 3a-)-..)3
City State / Province Zip / Postal Code
(Seal)
(Seal)
t r A)
Print ame
Co -Owner or Wdness (Seal)
Print Name
Customer acknowledges receipt of a true copy which was completely filled in prior to Customers execution hereof. You the customer may cancel this transaction
at any time prior to midnight on the third business day after the date of this transaction. See the attached Notice of Right to Cancel for an explanation of
this right.
Store 1657 Project No. 474097043 for KATHLEEN ROBERTS Page 4 of 7
V
%0
m
cn
r
A
N
co
r
Cn
m
a
a
3
RECORD COPY
Fbddad SCIS Nome I Log In I User Registration I Hot Topics I submit Surcharge I Stats It Facts I Publications I FSC Stan I 11CIS site Map I Unks I Search I
Bushes Product Approval
Professi I &USEWPublicUser
Regulation
Product Aooroval Menu > duet or Aoolicatbn Sea= > Application Yat
Search Criteria
Code Version
2014
FLS
8228.1
Application Type
ALL
Product Manufacturer
ALL
Category
ALL
Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Name
ALL
Product Description
ALL
Approved for use In HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact Resistant
ALL
Design Pressure
ALL
Otter
ALL
Search Results - Aooliutlons
f1A
I=
Manufacturer
Validated By
StatuS
FL8228-
Affirmation
Masonite International
National Accreditation & Management
Approved
8Z
FL*: FL8228.1
Institute
HIsto
Model: Fiberglass Side -Hinged Door Unit
(804) 684-5124
Description: 6'-8' Opaque I/S and O/S
Single Door
Category: Exterior Doors
Subcategory: Swinging Exterior Door
Assemblies
*Approved by DBPR. Approvals by DBPR shell be revie - and ratified by the POC and/or the Commission 0 necessary.
Contact Us :: 1940 North Monroe Sheet. Tallahassee FL 32399 Phone: 850.187-1824
The State of Florida Is an WEED employer. Comrloht 2007-2013 State or Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida low, email addresses are public records. It you do not want your e -mall address released In response to a public:-retords request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. It you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address U they have one. The
emacs provided may be used for official communication with the licensee. However email addresses are public record. It you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine U you are a licensee under Chapter 455, F.S., please
dick ftM.
Product Approval Accepts:
0®®®
REVIEWED POR CODE COMPLIANCE
01
PLANS EXAMINER
DATE
CreditSAFE
SANFORD BUILDING DIVISION
A PERMIT 136UED SHALL BE CONSTRUED TO BE A
LICENSEAUTHORITY PROCEED S
O VIOLATE, CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING TI
CONST UCT ON OR VIOLATIONS OF THIS CODE
0 -DING
SANrOR�
r
QC paK,�Fi
16-1 x,15
SIDE -HINGED FIBERGLASS DOOR UNIT
6'-8' DOUBLE DOOR WITH / WITHOUT SIDELITES
GENERAL NOTES
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7. MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
DOES NOT EXCEED THE DESIGN PRESSURES LISTED,
2. WHEN HURRICANE PPRROTECTIVED IN EHIGH VELOCITY SYSTEM (SHUTTERS) IS REQUIRED.
E ZONE (HVHZ).
EQUIRED.
3. WHEN INSTALLED IN THE WINO -BORNE DEBRIS REGION.
EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ).
NURICJNE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAOUE
PANELS OR PANELS WITH IMPACT CLASS. BUT IS REQUIRED
ON PANELS WITH NON -IMPACT GLASS.
4. POLYUREnUNE CORE FLAME SPREAD RAM OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM EBI.
POLYSTYRENE CORE FLAME SPREAD INDEX OF 15
AND SMOKE DEVELOPED INDEX OF 115 PER ASTM E54.
5. PLASTICS TESTING OF nsamASS FACING:
TEST DESCRIPTION OESIGNATION RESULT
SELF IGNITION TEMP
1ASTM OIp2p
752 'F > 650 'F
RATE OF BURNING
in 0835
0.58 ININ
SMOKE DENSITY
I ASTM 02843
53.4X
TENSILE STRENGTH-
I ASTM 0638
3.2X OIFF
6. PLASTICS TESTING OF LITE FRAME MATERIAL:
TEST DESCRIPTION DESIGNATION RESULT
• COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
7. IMPACT GLAZING LAMINATE NMI OAK BCCO NOA 09-0127.13
O0 00 C30 000 13
.00 00:00 00. .00
00 0000 000 00
SINGLE DOOR UMi DOUBLE DOOR UNIT SINGLE DOOR I1NR SINGLE DOOR UNR
WITH Simi IE WITH SIDELIIE
TABLE OF CONTENTS
SHEET / DESCRIPTION
TYPICAL ELEVATIONS k GENERAL NOTES
AN HOR TIONS AI
3 AN RING Mrs R AI.S
mbWIbwm
Qualls N160&9V-2,
i
0ll 0 0 11 o aooll 000
er je 909
Ir0r. N.T.S.
sc.IN' $W;
cw er.
KURT SALTHAZOR 0%=Mo N 4
FLORIDA P.E. OWG-MA-A 0161
1565M
94M _L OF
149' MAX. OVERALL FRAME 01H
21' MAK 36.375' MAX.
O.L.O. PANEL N90TH r 37.5' MAX.
W/ASTRACAL 1 FRAME KROTH
.
RATE OF 9URM.0 ASTM 0635 0.77 IN YIN
SMOKE OENSMY 1 ASTM 02643
TENSILE SIR IN- I ASTM D636I -7.501L OFF
I I
o
Sol
• COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
7. IMPACT GLAZING LAMINATE NMI OAK BCCO NOA 09-0127.13
O0 00 C30 000 13
.00 00:00 00. .00
00 0000 000 00
SINGLE DOOR UMi DOUBLE DOOR UNIT SINGLE DOOR I1NR SINGLE DOOR UNR
WITH Simi IE WITH SIDELIIE
TABLE OF CONTENTS
SHEET / DESCRIPTION
TYPICAL ELEVATIONS k GENERAL NOTES
AN HOR TIONS AI
3 AN RING Mrs R AI.S
mbWIbwm
Qualls N160&9V-2,
i
0ll 0 0 11 o aooll 000
er je 909
Ir0r. N.T.S.
sc.IN' $W;
cw er.
KURT SALTHAZOR 0%=Mo N 4
FLORIDA P.E. OWG-MA-A 0161
1565M
94M _L OF
SELF IGNITION TEMP ASTM 01929 740 'F > 650 'F
.
RATE OF 9URM.0 ASTM 0635 0.77 IN YIN
SMOKE OENSMY 1 ASTM 02643
TENSILE SIR IN- I ASTM D636I -7.501L OFF
• COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
7. IMPACT GLAZING LAMINATE NMI OAK BCCO NOA 09-0127.13
O0 00 C30 000 13
.00 00:00 00. .00
00 0000 000 00
SINGLE DOOR UMi DOUBLE DOOR UNIT SINGLE DOOR I1NR SINGLE DOOR UNR
WITH Simi IE WITH SIDELIIE
TABLE OF CONTENTS
SHEET / DESCRIPTION
TYPICAL ELEVATIONS k GENERAL NOTES
AN HOR TIONS AI
3 AN RING Mrs R AI.S
mbWIbwm
Qualls N160&9V-2,
i
0ll 0 0 11 o aooll 000
er je 909
Ir0r. N.T.S.
sc.IN' $W;
cw er.
KURT SALTHAZOR 0%=Mo N 4
FLORIDA P.E. OWG-MA-A 0161
1565M
94M _L OF
3- -
SEE DETAIL
.c.
3'
6-
SEE DETAIL
3- 3
4t
3.
I I I
16- 6-
- —i�
6-11-
I I I
-
3'
1O
_
c
Y
_
A
W
W B
8
B
6- 3.
m
r6,
6•
I
1
I
I%3•
3'
ti
I
3-
3-
3
L 3•
r
6'
X
I-
18 x 2-1/2" #10 x 2"
"
18 x 2-1/2" X10 x 5/8 110 x 314-
0 #10 x 5/8- #10 x 3/4"
10 x 2. FRAME / DOOR
DETAIL "D" DETAIL "C"
TYPICAL
in
N
6.
Adurdpown
lyl�/onlh: N 6 0 . �z i
Ads sr
#8 x 2- 1/2-
ASTRA
MUST 8
THE TH
QUAIL '"E" ASTRAGA! STRUCT
FOR A
ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME DETAIL F" ASTRAGAL
AS SHOWN.
0.124• ANNE"D OEOORA %C Q4=T
0010' SVLEX 81c (OPnom.) OOM 632`
0 124' AtO E40 +- •0124' TEMP. \\`
1
1 o.66z1 -
1.375"
T - T T
�N-,' THRESHOLD OUTSWING THRESHOLD HIGH DAM O/S THRESHOLD
n,
h,
ME DETAIL
c-
h
1
6 -
GAL RETAINER BOLT HOLE
E DRILLED THROUGH
RESHOLD & INTO THE
URE DEEP ENOUGH
1.375" THROW
r /a x 1-V2' v►1s
4
DOM 632 ''� DOM 632 •� �V_ :`
r,'
ooM 632 : '.1-.�,.,
1lQEtQlm
TYPICAL GLAZING DETAIL TYPICAL GlAZIF:G DETAIL
IMPACT RATED GLASS NON—IMPACT CLASS
N.T.S.
or, Fi
or.
;A1F.o-C
OF 3
SEE DETAIL
'C SMT. 2
3' -1 I-
ATTACHMENT DETAIL
I. ANCHOR ANALYS'S FOR LOADING CONDITIONS PREPARED.
SIGNED AND SEALED BY LUIS R. LOMAS. PE
(FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE
#10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL
SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE- MIN 2-5/8
2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE
FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO
BACK JAMB UNITS JOINED WITH 1 " X 1/2- LONG
CORRUGATED FASTENERS LOCATED 3" FROM EACH END
AND MAXIMUM 7" O.C. OR #10 X 2" FLAT HEAD WOOD
SCREWS LOCATED 6' FROM EACH END AND MAXIMUM
12" O.C.
3. THE W000 SCREW SINGLE SHEAR DESIGN VALUES COME FROM
ANSI/AF&PA NOA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE
MINIMUM EMBEDMENT OF 1-1/4".
4. W000 BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO
TRANSFER LOADS TO STRUCTURE.
5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS.
6�3� I I 6 c —I {— 3i
I I I
1� I I
6' 6'
I I I
m
N
W
I II
C H
11 II
B
II I
B
•
io
3" —4 T —
1.5H0
N
CL _1 1_
:rte
TYPICAL WOOD BUCK
ANCHOR INSTALLATION
t 3 l I I t 6, �
6' —1-1
11� 1-{,-jll"__ 6'
ARDWARE SCHEDU
1. JKWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED
AT 5-1/2" CENTERLINE.
2.14' X 4' FULL MORTISE BUTT HINGES.
IN 0.25'
MAXS
CL _I I_
HIM
y
TYPICAL MASONRY
ANCHOR INSTALLATION
AdbdllblWl
� r
suu: H.T.S.
ww er. i
o« Or
or