HomeMy WebLinkAbout112 Hidden Arbor Ct0 1 i+ CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATIONDi
Application No: Lp S
Documented Construction Value: $
i
Job Address: Ai l C e i .'QS 11 (.T SY YI I f - n Historic District: Yes No g
Parcel IDS
Type of Wi
Description of Work:
Residential- Commercial
Demo Change of Use Move
Plan Review Contact Person: _- ( Title: `-t),
Phone: 9 ()1- !- Gj ?,
c_-
Fax: j- - j j C Email: QrC h i ! 1 f1
Property Owner Information
Name- T6P kMys1 inr Phone: N
Street: ..ICI hl(.n I 0 Resident of property? : Q
city,_State.Zip: _`j(1:lrb I D2
Contractor Information
Name _ uort-'- `Zoc i n(2 Phone:—
Street:-i(1a,S (j% 4 to A : )i (-IFax: _ _ ior) - 5q a City,
State Zip: Ic-Dy D nrrnY\-i cj State License No.: Architect/
Engineer Information CCC 058 Name:
Phone: Street:
Fax: City,
St, Zip: E-mail: Bonding
Company: Address:
T J / - Mortgage
Lender: Address:
WARNING
TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Application
is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced
prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in
this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces,
boilers, heaters, tanks, and air conditioners, etc. FBC
105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised:
June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may befoundinthepublicrecordsofthiscounty, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, inaccordancewithlocalordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
i o er/Agent Date CSigna re of Contract /Agent Date
Print Owner/Agent's Name
Print Contractor/Agent's Name
r
wafflp
S' nagt t'br, 10,ry-Statedfilp E P LIMA ate Signature of Notary-S
Notary Public - State of Florida rw"" CONS7ANCE P LIMA
ices Sep 23,2018 Notary Public - State of FloridaMyComm. Exp °My Comm. Expires Sep 23.2018
Commission # FF 142441 Commission # FF 142441
Contractor/Agerit is V Personally Known to Me orOwner/Agent is Personally Known to Me or
Produced ID Type of ID Produced ID Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required:
Construction Type:
Total Sq Ft of Bldg:
Building Electrical Mechanical Plumbing Gas Roof
Occupancy Use:
Min. Occupancy Load:
New Construction: Electric - # of Amps
Fire Sprinkler Permit: Yes No
APPROVALS: ZONING:
ENGINEERING:
COMMENTS:
Flood Zone:
of Stories:
Plumbing - # of Fixtures
of Heads Fire Alarm Permit: Yes No
UTILITIES.
P
WASTE WATER:
BUILDING:
Revised: June 30, 2015
Permit Application
CG-C15141.46 * CM-CO57129 * CC-CO58158 * CG-CO58633
NAME OF CLIENT: THE ARBORS AT HIDDEN LAKE
SERVICE ADDRRESS: 200 ARBOR CIR. SANLILQl l) FL and 101 HIDDEN ARBOR CT.
CONTACT: CIO WORLD OF HOMES Attention:]Jzbeth Martell
2884 S. OSCEOLA AVE, LirlmtIttnarte.I1(ci4orld0l110Ines. ne( ORLANDO,
FL 32806 PHONE:
407-770-1748 ext. 207 SCOPE
OF WORK - ROOF
REPLACEMENT FOR rOLLOWING BUILDINGS AND UNITS: 1.
BUILDING 200 ARBOR CIRCLE (20012021204/206) 4 UNITS 2.
225 ARBOR CIRCLE (ONLY ONE UNIT) 3.
207 ARBOR CIRCLE 4.
215 ARBOR CIRCLE 5.
219 ARBOR CIRCLE 6.
BUILDING 101 HIDDEN ARBOR CT (101 AND 103) 2 UNITS ONLY 7.
BUILDING 107 HIDDEN ARBOR CT (107/109/111) 3 UNITS 8.
121 RIDDEN ARBORI 127 AND 129 HIDDEN ARBOR (3 UNITS OF 5) 9.
BUILDING 131 HIDDEN ARBOR CIRCLE (3 UNITS) 10.
118 HIDDEN ARBOR CIRCLE ROOF
INVESTMENT PROPOSAL. FOR: MISSION
STATEMENT Building
EMT's pledges to maintain its core values by providing superior workmanship, excellent customer service
and utilizing only the highest quality materials, Building
EMTs LLC * 7025 CR 46A, Suite 1071 #433 * Lake Mary, Florida 32746 P:
800.854.7663 * F: 800.532.9597 www.
Buildin-qEMTs.com
BUILDING A k
Ts
1 Remove existing roof system, then Inspect and replace any required rotted or deteriorated decking (96 Squa
Feet OR 3 Sheets FREE).
2- If your roof decking does not meet the current code we will be required to ensure this standard is met by
renailing the decking prior to inspection (deck must meet code).
3. Replace all vent boots and flashing as needed for FREE.
4. Apply ice and water shield PER CODE.
5.
Install new 25 year 3-Tab shingles. Per the Manufacturer's current installation guidelines.
6- All roofing debris will be cleaned up daily and hauled away for proper disposal at the end of each project. A
nail -gathering device will be passed over the jobsite to retrieve nails and screws, which may have fallen into
the grass.
BUILDING EMTs PRICING
Price includes materials, sales tax on materials, permits, labor, inspection fees and landfill costs
choose one)
X25 year 3 Tab shingles over Manufacturers Approved Underlayment
Total Price: $101,089.00
NOTE. All 30 Year shingles come with a Signature Select Premium Protection Period of 6 Years
labor and material). Ask estimator for details.
Lifetime Architectural Atlas Pinnacle shingles over Manufacturers Approved Underlayment
Total Price: $0.00
NOTE. AU Lifetime Atlas Pinnacle Brand shingles come with a Signature Select Premium Protection
Period of 10 Years (labor and material). Ask estimator for details.
F-IGUTTER OPTION
Installation of V seamless gutters with downspouts around entire perimeter of residence.
Total Price:
SPECIAL NOTES:
BUILDING EMT's PAYMENT TERMS .
ISTANDARD PAYMENT TERMS: 50% down with remaining 50% upon completion
IF PAYING WITH CREDIT CARD A 3.5% FEE WILL BE ADDED TO THE COST (Visa and MasterCard Only)
Building EMT's LLC * 7025 CR 46A, Suite 1071 #433 * Lake Mary, Florida 32746
P: 800.854.7663 * F: 800.532.9597
www.BuildingEMTs.com
BUILDING
TS
EMTs Warranty -The new roof system shall have a Five (5) year Contractors warranty and a (25) year limited warranty from the
er. Any damage caused by outside influences will be repaired at the owner's expense, including but not limited to;
1. Extreme weather and other ads of God
2. Servicemen other than BUILDING EMT's Roofing personnel working on the roof surface causing damage to the roofassembly
3. Any substance or material being placed or deposited on the roof surface causing damage to the roof assembly
4. Any standard language in the manufacturer's warranty
nanship -All new roofing work will be installed per the Manufacturers, NRCA and SMACNA details. Work performed will be carried out in an
it and workmanlike manner by experienced roofers.
Compliance - All work performed will meet or exceed Florida Building Code and all applicable local building codes. Permit will be pulled and
ad by BUILDING EMl's, Inc.
or Protection - BUILDING EMTs will take normal precautions to protect your lawn and shrubs during the course of the roofing project. At
it may be necessary to place dump trailers In the yard to gain access to a point closest to the property. We ask property owners to park their
as on the street during the roofing project to prevent any fire damage. BUILDING EMTs assumes no liability for damage to driveways, lawns,
ers, water lines, sanitary lines or tanks caused by the shingle suppliers' truck or equipment.
urance Coverage - As one of the top companies in Florida, BUILDING EMTs is chosen frequently to perform complex and challenging roofing
jects for both private and government clients which require high levels of insurance. All of our workers are covered by Florida Workman's
mpensation insurance In the amount of $100,000 per employee. BUILDING EMTs also carries $2 Million in General Liability Insurance as well as
Million In Fleet Insurance.
Safety & Privacy - BUILDING EMTs has one of the most talented roofing teams in the industry. We are committed to hiring the most
ad individuals to conduct your roofing project. All of our workers are drug tested and receive regular safety training.
ny claims for damage must be submitted to BUILDING EMT's within ten (10) days from the date the job Is completed.
BUILDING Mrs TERMS AND CONDITIONS
This proposal is valid for 30 days from the date specified on page one and is void thereafter. This project will be 100% complete within DjEbt (30)
tendar days from date of execution (weather permitting). Rain day extensions will be two (2) days for everyday weather is considered non-
inducive to roofing, as determined by BUILDING EMTs. BUILDING EMTs will not be responsible for any mechanical, plumbing or electrical
odifications necessary to complete the work; any additional costs involved with the protective covering or disconnecting of ANY electrical lines
ecessary to complete the work; for realignment or recalibration of any roof top satellite dishes, lighting protection systems or any other apparatuses
i or connected to the roof; or for the detection, abatement or disposal of any hazardous materials associated with the above mentioned work.
All materials guaranteed to be as specified. All work to be completed in workmanship like manner according to standard practices. All agreements
ntingent upon strikes, accidents or delays beyond our control. BUILDING EMT's insurance coverage meets or exceeds ail slate, county or city
quirements. Owner to carry Fire, Tornado and other necessary insurance, including builders risk at owner's expense, If requested. if the owner
innot purchase a builders risk policy within 10 days of acceptance, BUILDING EMf's will purchase said policy and add the cost to the contract.
The property owner, unless otherwise specified, grants BUILDING EMTs the right to post a yard sign in the front yard and use the home address,
well as photos of the property, for marketing purposes on flyers, emalls or our website.
CEPTANCE OF PROPOSAL: The above prices, specifications, terms and conditions are satisfactory and are hereby accepted. BUILDING EMT`. -
authorized to do the work as specified. Payment will be made as outlined above. Heavy trucks and equipment may be used to remove old roofing
aterlals and deliver new materials, any damage to sidewalks, driveways, or lawn will be the responsibility of the homeowner. Interest on past due
ims shall accrue from the due date at the highest rate allowable under Florida law. In any legal actions brought for enforcement or interpretation of
Is agreement, the prevailing party shall also recover all costs including reasonable attorney fees.
of Proposal: 11127i2015 BUILDING EMT's Signature:
of Acceptance: /_%'u2 t / f S Customer
Building EMT's LLC * 7025 CR 46A, Suite 1071 #433 * Lake Mary, Florida 32746
P: 800.854.7663 * F: 800.532.9597
www.BuildingEMTs.com
The Arbors at Hidden lake
Building Sq Ft Price
101 11088.50 21342.46
103 1088.5 2,342.46
107 11184 5,000.00
109 1,184 5,000.00
111 11184 5,000.00
112 1,581 6,804.62
118 1,212 5,216.45
121 1,147.33 4,938.12
127 11147 33 41938.12
129 1,147.33 4,93812
131 803.66 31458.98
1331. 803.66 31458.98
135 803.66 3,458.98
200 991.5 3,847.34
202 991.5 3,847.34
204 991.5 3,847.34
206 991.5 3,847.34
207 1132 4,872.13
215 1223 11,965.10
219 1390 5,982.56
225 1390 5,982.56
Total Price: $101,089.00
a .nnn logil 18C11 leaf
THIS INSTRUMENT PREPARED BY:
Name,
Address:'_Af7A f e qt.e 1A
17_11 Y<c vna a: Zi
NOTICE OF COMMENCEMENT
State of Florida
County of Seminole
Permit Number:
MARYANNE NORSEr SEMINOLE COUNTY
CLERK OF CIRCUIT COURT t, COMPTROLLERetc8623Pq101; (1F9s)
CLERK'S Y 2016009990
RECORDED 011'28/2t_11„ 03:00:1i0 Pf1
RECORDING FEES $1? .00
RECORDED BY hdevere
Parcel ID Number. =n' - t'J OP 00 — (i 0 Q
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available)
GENERAL DESCRIPTION OF IMPROVEMENT:
OWNERjWRM TI jN: ' i
Name: ,il 1-irt7f)J ( t d '_ I:t11i()(' eI S SSLC K_i,-LrA In C
Address:
Fee Simple Title Holder (if,other than
CONTRACTOR:
Address:
Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served
as provided by S ction 713.13(1)(b),
AFlo
tatutes. eName:
cusllP_Llow-owileiASCicaim Me- `JL} ti
s-oo En-t frls' Address: In
addition
to himself, Owner Designates of To receive
a copy of the Lienor's Notice as Provided in Section 713.
13(1)(b), Florida Statutes. Expiration Date
of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date
is specified) WARNING TO
OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES,
AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF
YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING
WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties
ofp"erjury, 1 declare that 1 have read the foregoing and that the facts stated in it are ttr;e ;ur;le, to the
best of my no dge a d elief.ofi Ownhr s
Owners Printed Name G ' FloridaS
a W 1 3(1)( o st sign the notice of commencement and no one 11. may be permitted to sign in his or her stead 11 7 :-
0t v W
c c
o State of (
t^ e County of (l) Q )Ylt P Q The foregoing
instrument was acknowledged before me this day of Y11A9,f-U , 20 by /'11G (
1 LA LS. ( (o 1 .
Who
is personally known to me ¢ t= Namof erson
making statement 1 OR who
has produces identification type of Identification produced: Judah Burton
n_ u_
Commission # FF937650
Expires, November
19, 2019 to Signet t' Bonded
thro
Aaron Notary 1,ttttt
Technical Data Sheet
XTT"' 30 Shingles
XTTM 25 Shingles
CT20TM Shingles
PRODUCT INFORMATION
CertainTeed offers a variety of three -tab shingle products that
combine exceptional durability with flexibility for better resistance to
blow -off. In addition to their suitability for residential applications,
these products are ideal for commercial applications. Available in
English" dimensions —12" x 36" and in "Metric" dimensions —13 1 /4"
x 39 3/8", depending on the product and sales region.
Algae Resistant (AR) versions of these shingles are available in some regions. Algae resistant shingles
help protect against staining or discoloration caused by algae.
Colors: Please refer to the product brochure or CertainTeed website for the colors available in your
region.
Limitations: Use on roofs with slopes greater than 2" per foot. Low slope applications (2" to 4" per foot)
require additional underlayment. In areas where icing along the eaves can cause a backup of water,
apply CertainTeed VlfinterGuardTm Waterproofing Shingle Underlayment, or its equivalent, according to
application instructions provided with the product and on the shingle package.
On slopes greater than 21" per foot, apply a spot of roofing cement under each shingle tab corner
according to application instructions provided on the shingle package.
Product Composition: These shingles are composed of a fiber glass mat base. Ceramic -coated mineral
granules are tightly embedded in carefully refined, water-resistant asphalt. These shingles have self-
sealing adhesive. These are 3-tab shingles.
Applicable Standards:
ASTM D3018, Type I
ASTM D3462
ASTM E108 Class A Fire Resistance
ASTM D3161 Class F Wind Resistance
ASTM D7158 Class H Wind Resistance
UL 790 Class A Fire Resistance
CC -ES Evaluation Report ESR-1389
ICC-ES Evaluation Report ESR-3537
CSA Standard A123.5 (except CT20 & XT 25 English)
Florida Product Approval # FL5444
Miami -Dade Product Control Approved (Regional)
Technical Data: XT 30 — English
Weight/Square (approx.): 215 Ibs
Dimensions (overall): 12" x 36"
Shingles/Square: 80
Weather Exposure: 5"
XT 25 — English XT 25 — Metric
Weight/Square (approx.): 205 Ibs 220 Ibs
Dimensions (overall): 12" x 36" 13-1/4" x 39-3/8"
Shingles/Square: 80 65
Weather Exposure: 5" 5-5/8"
CT 20 — English CT 20 — Metric
Weight/Square (approx.): 195 lbs 195 Ibs
Dimensions (overall): 12" x 36" 13-1/4" x 39-3/8"
Shingles/Square: 80 65
Weather Exposure: 5" 5-5/8"
Technical Data Sheet (Continued)
Strip Shingles Page 2 of 3
INSTALLATION
The following is a general summary of the installation methods. Detailed installation instructions are
supplied on each bundle of strip shingles and must be followed. Separate application sheets may also be
obtained from CertainTeed.
Roof Deck Requirements: Apply shingles to minimum 3/8" thick plywood, minimum 7/16" thick non -
veneer (E.g. OSB), or minimum 1" thick (nominal) wood decks. The plywood or non -veneer decks must
comply with the specifications of APA-The Engineered Wood Association.
Ventilation: Provisions for ventilation should meet or exceed current HUD Standards. To ensure
adequate balance ventilation, use a combination of continuous ridge ventilation (using CertainTeed Ridge
Vent products, or a comparable product with an external baffle) combined with soffit venting.
Valleys: Valley liner must be applied before shingles. The Closed -Cut valley application method is
recommended, using CertainTeed WinterGuard Waterproofing Shingle Underlayment, or its equivalent, to
line the valley prior to being fully covered by the shingles.
Underlayment:
On slopes 4" per foot or greater, CertainTeed recommends one layer of DiamondDeckTm Synthetic
Underlayment, or Roofers' Select"" High -Performance shingle underlayment, or shingle underlayment
meeting ASTM D226, D4869 or ASTM D6757. Always ensure sufficient deck ventilation, and take
particular care when DiamondDeck or other synthetic underlayment is installed. For UL fire rating,
underlayment may be required. Corrosion -resistant drip edge is recommended and should be placed over
the underlayment at the rake and beneath the underlayment at the eaves. Follow manufacturer's
application instructions.
On low slopes (2" up to 4" per foot), one layer of CertainTeed's WinterGuard Waterproofing Shingle
Underlayment (or equivalent meeting ASTM D1970) or two layers of 36" wide felt shingle underlayment
Roofers' Select High -Performance Underlayment or product meeting ASTM D226, D4869 or ASTM
D6757) lapped 19" must be applied over the entire roof, ensure sufficient deck ventilation. When
DiamondDeck or other synthetic underlayment is installed, weather -lap at least 20" and ensure sufficient
deck ventilation. When WinterGuard is applied to the rake area, the drip edge may be installed under or
over WinterGuard. At the eave, when WinterGuard does not overlap the gutter or fascia, the drip edge
should be installed under WinterGuard. When WinterGuard overlaps the fascia or gutter, the drip edge or
other metal must be installed over it. Follow manufacturer's application instructions.
Fastening: Four nails are required per shingle. For English -sized shingles they are to be located 5/8"
above the top of each cutout and 1" and 12" in from each side of the shingle. For Metric -sized shingles
they are to be located 1" and 13-1/8" in from each side of the shingle. They must be of sufficient length to
penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to be 11
or 12 gauge, corrosion -resistant roofing nails with 3/8" heads.
On steep slopes greater than 21" per foot, apply a spot of roofing cement under each shingle tab corner
according to application instructions provided on the shingle package.
Application (English -Sized Shingles): The recommended application method is the Six -Course, 6"
Stepped -Off Diagonal Method found on each bundle of shingles. These shingles may also be applied
using the 5" Stepped -Off Diagonal Method, or the 6" Offset, Single -Column Vertical -Racking Method,
instructions for which may be obtained from CertainTeed. These shingles may be used for new
construction or for re -roofing over old shingles.
Technical Data Sheet (Continued)
Strip Shingles Page 3 of 3
Application (Metric -sized shingles): The recommended application method is the Seven Course, 5-5/8"
Stepped -Off Diagonal Method found on each bundle of shingles. These shingles may also be applied
using the Eight Course, 5" Stepped -Off Diagonal Method or the Half -Tab Diagonal Method, instructions
for which may be obtained from CertainTeed. These shingles may be used for new construction or for
reroofing over old shingles.
Flashing: Use corrosion -resistant metal flashing.
Hips and Ridges: Use field shingles of a like color for capping hips and ridges.
MAINTENANCE
These shingles do not require maintenance when installed according to manufacturer's application
instructions. However, to protect the investment, any roof should be routinely inspected at least once a
year. Older roofs should be looked at more frequently.
WARRANTY
XT 30 (and AR), shingles carry a 30-year limited transferable warranty, XT 25 (and AR) carry a 25-year
limited transferable warranty, and CT 20 (and AR), shingles carry a 20 year limited transferable warranty
to the consumer against manufacturing defects. All of these shingles carry 5-year SureStart protection
except for CT 20 which carries 3-year SureStart protection. For specific warranty details and limitations,
refer to the warranty itself (available from the local supplier, roofing contractor or on-line at
www.certainteed.com).
FOR MORE INFORMATION
Sales Support Group: 800-233-8990
Web site: www.certainteed.com
See us at our on-line specification writing tool, CertaSpec, at www.certainteed.com/certaspec.
CertainTeed Roofing
P.O. Box 860
Valley Forge, PA 19482
Copyright CertainTeed Corporation, 2015
All rights reserved. Updated: 0512015
SAINT-GOBAIN