HomeMy WebLinkAbout118 Hidden Arbor CtCITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
F. D
3 Application No: t " 9 j
Documented Construction Value: $ 15 3 1 V . y S
Job Address: ef)i CT 513n( Yn -F, -aM Historic District: Yes No Z
Parcel ID L I — - . ResidentiagErCommercial
Type of Work: New Addition ElAlterations Repair Demo Change of Use Move
Description of Work: & - M)F1 0 (,{
Plan Review Contact Person: Title:AC
Phone: g 0-1- 55) Fax: j-- q(56J-4 Email: rjUt C C1C1 :m CS CUrr)
Property Owner Information
Name' Y, I Phone: N I IN
Street: Resident of property? : t
City;_ State;Zip:
Contractor Information
Name boo_ ece koca n(2 Phone: -1- ?,
Street: A °y Fax:
City, State Zip: I r'C p 1 YYJrt.l 1= 1 State License No.S(il QO(
Architect/Engineer Information I S
Name: Phone:
Street: N H Fax:
City, St, Zip: E-mail:
Bonding Company:
Address: T MortgageLender: Address
WARNING
TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Application
is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced
prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in
this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, welts, pools, furnaces,
boilers, heaters, tanks, and air conditioners, etc. FBC
105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5t1 Edition (2014) Florida Building Code Revised:
June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is requiredinordertocalculateaplanreviewchargeandwillbeconsideredtheestimatedconstructionvalueofthejobatthetimeofsubmittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the, actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
1Z.1 _ - t •ll Ai Jofer/Agent Date Signa ure of Contract /Agent Date
Print Owner/Agent's Name
Print Contractor/Agent's Name
rn r 1
nat:v— lirJ;,9Pry-Statedh19l E P LIMA pate
Notary Public - State of Florida
r , t • . ,, My Comm. Expires Sep 23.2018
Commission 11 FF 142441
Owner/Agent is Personally Known to Me or
Produced ID Type of ID Produced ID
V
Type of ID
BELOW IS FOR OFFICE USE ONLY
Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof
Construction Type: Occupancy Use: Flood Zone:
Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No
APPROVALS: ZONING: UTILITIES: WASTE WATER:
ENGINEERING: FIRE: BUILDING:
COMMENTS:
Revised: June 30, 2015
Permit Application
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING BOARD
WE1940 NORTH MONROE STREET TALLAHASSEE
FL 32399-0783 BONNER,
GREGORY FOSTER BONNER
ROOFING & SHEET METAL COMPANY 7025
CR 46A SUITE
1071 #433 LAKE
MARY FL 32746 Congratulationsi
With this license you become one of the nearly one
million Floridians licensed by the Department of Business and Professional
Regulation. Our professionals and businesses range from
architects to yacht brokers, from boxers to barbeque restaurants, and
they keep Florida's economy strong. Every
day we work to improve the way we do business in order to serve
you better. For information about our services, please log onto www.
mytioridalleense.com. There you can find more information about
our divisions and the regulations that impact you, subscribe to
department newsletters and learn more about the Department's initiatives.
Our
mission at the Department is: License Efficiently, Regulate Fairly. We
constantly strive to serve you better so that you can serve your customers.
Thank you for doing business in Florida, and
congratulations on your new license! RICK
SCOTT, GOVERNOR LICENSE
Nl3M8ER GCCQ58158
The.'
R000FI NG:CONTRACTOR Named
below IS CERTIFIEp - DETACH
HERE STV
DEI
PRI
850)
487-1395 OF
FLORIDA:- IT
OF BUSINESS AND SIONAL
REGULATION KEN
LAWSON, SECRETARY STATE
OF.FLORIDA 51NESSAND _
PROFESSIONAL REGULATION s ION. INDUSTRY
LICENSING:BOARD L LEI
MPANY" r
a.
h
5
ISSUED:
08/
05/2014 DISPLAY AS REQUIRED BY LAW SEQ# L1408050001514
CG-C15141.46 k CM-CO57129 * CC-CO58158 * CG-CO58633
NAME OF CIA, NT: THE ARBORS AT RIDDEN LAME
SERVICE AllDRRESS: 200 ARDOR CIR._SAN}?Oltl) FX, end 101 IIIDDEN ARBOR GT.
CONTACT: C/O WORLD OF HOMES Attention:Lizbeth Martell
2884 S. OSCEOLA AVE Li-7bet l€€t arteat ithvorldoIII ()ole.s.t€et' ORLANDO, FL
32806 PHONE: 407-
770-1748 ext. 207 SCOPE OF
WORK. - ROOT' REPLACEMENT
FOR FOLLOWING BUILDINGS AND UNITS: I. BUILDING
200 ARBOR CIRCLE (2001202/204/206).1 UNITS 2. 225
ARBOR CIRCLE (ONLY ONE UNIT) 3. 207
ARBOR CIRCLE 4. 215
ARBOR CIRCLE 5. 219
ARBOR CIRCLE 6. BUILDING
101 HIDDEN ARBOR CT (101 AND 103) 2 UNITS ONLY 7. BUILDING
107 HIDDEN ARBOR CT (1071109/111) 3 UNITS. 8. 121
HIDDEN ARBOR/ 127 AND 129 HIDDEN ARBOR (3 UNITS OF 5) 9. BUILDING
131 HIDDEN ARBOR CIRCLE (3 UNITS) 10. 118
HIDDEN ARBOR CIRCLE ROOF INVESTMENT
PROPOSAL. FOR: DATE Castille
I
The Arbors at Hidden Lake NAME of
Homes
770-1748
or FAX
rEET CITY,
STATE
AND ZIP CODE S. Osceola
Ave, Orlando, Florida 32806 11 /27/
2015 MISSION STATEMENT
Building EMT'
s pledges to maintain its core values by providing superior workmanship, excellent customer service and
utilizing only the highest quality materials. Building EMT'
s LLC * 7025 CR 46A, Suite 1071 #433 * Lake Mary, Florida 32746 P: 800.
854.7663 * F: 800.532.9597 wrww.BuildingEMTs.
com
ION
N116BUILDING
AFEmTs-
1 Remove existing roof system, then Inspect and replace any required rotted or deteriorated decking (96 Squa
Feet OR 3 Sheets FREE).
2. If your roof decking does not meet the current code we will be required to ensure this standard is met by
renainng the decking prior to inspection (deck must meet code).
3. Replace all vent boots and flashing as needed for FREE.
4. Apply ice and water shield PER CODE.
5.
Install new 25 year 3-Tab shingles. Per the Manufacturer's current installation guidelines.
6- All roofing debris will be cleaned up daily and hauled away for proper disposal at the end of each project. A
nail -gathering device will be passed over the jobsite to retrieve nails and screws, which may have fallen into
the grass.
BUILDING EMT's PRICING
ice includes materials, sales tax on materials, permits, labor, inspection fees and landfill costs
choose one)
X 25 year 3-Tab shingles over Manufacturers Approved Underlayment
Total Price: $101,089.00
NOTE. All 30 Year shingles come with a Signature Select Premium Protection Period of 6 Years
tabor and material). Ask estimator for details.
Lifetime Architectural Atlas Pinnacle shingles over Manufacturers Approved Underiayment
Total Price: $0.00
NOTE. All Lifetime Atlas Pinnacle Brand shingles come with a Signature Select Premium Protection
Period of 10 Years (labor and material). Ask estimator for details.
GUTTER OPTION
Installation of 6" seamless gutters with downspouts around entire perimeter of residence.
Total Price:
SPECIAL NOTES:
BUILDING EMT's PAYMENT TERMS
OSTANDARD PAYMENT TERMS: 50% down with remaining 50% upon completion
IF PAYING WITH CREDIT CARD A 3.5% FEE WILL BE ADDED TO THE COST (Visa and MasterCard Only)
Building EMT's LLC * 7025 CR 46A, Suite 1071 #433 * Lake Mary, Florida 32746
P: 800.854.7663 * F: 800.532.9597
www.BuildingEMTs.com
BUILDING
EMTs VY
EMTs Warranty -The new roof system shall have a Five (5) year Contractors warranty and a (25) year limited warranty from the
er. Any damage caused by outside influences will be repaired at the owner's expense, Including but not Limited to:
1. Extreme weather and other acts of God
2. Servicemen other than BUILDING EMT's Roofing personnel working on the roof surface causing damage to the roof assembly
3. Any substance or material being placed or deposited on the roof surface causing damage to the roof assembly
4. Any standard language in the manufacturer's warranty
nanshtp -All new roofing work will be installed per the Manufacturers. NRCA and SMACNA details. Work performed will be carried out in an
at and workmanlike manner by experienced roofers.
Compliance - All work performed will meet or exceed Florida Building Code and all applicable local building codes. Permit will be pulled and
ad by BUILDING EMTs, Inc.
or Protection - BUILDING EMTs will take normal precautions to protect your lawn and shrubs during the course of the roofing project. At
It may be necessary to place dump trailers in the yard to gain access to a point closest to the property. We ask property owners to park their
is on the street during the roofing project to prevent any Lire damage. BUILDING EMTs assumes no liability for damage to driveways, lawns,
ers, water lines, sanitary lines or tanks caused by the shingle suppliers' truck or equipment.
urance Coverage -As one of the top companies in Florida, BUILDING EMTs is chosen frequently to perform complex and challenging roofing
jects for both private and government clients which require high levels of insurance. All of our workers are covered by Florida Workman's
mpensation insurance in the amount of $f00,000 per employee. BUILDING EMTs also carries $2 Million in General Liability insurance as well as
Million in Fleet insurance.
Customer Safety & Privacy - BUILDING EMTs has one of the most talented roofing teams in the industry. We are committed to hiring the most
experienced individuals to conduct your roofing project. All of our workers are drug tested and receive regular safety training.
Claims -Any claims for damage must be submitted to BUILDING EMT's within ten (10) days from the date the job is completed.
BUILDING Mrs TERMS AND CONDITIONS
This proposal is valid for 30 days from the date specified on page one and is void thereafter. This project will be 100% complete within Thirty (30)
lendar days from date of execution (weather permitting). Rain day extensions will be two (2) days for every day weather Is considered non-
nducive to roofing, as determined by BUILDING EMTs. BUILDING EMTs will not be responsible for any mechanical, plumbing or electrical
dificallons necessary to complete the work; any additional costs involved with the protective covering or disconnecting of ANY electrical lines
cessary to complete the work; for realignment or recafibration of any rooftop satellite dishes, lighting protection systems or any other apparatuses
i or connected to the root, or for the detection, abatement or disposal of any hazardous materials associated with the above mentioned work.
All materials guaranteed to be as specified. All work to be completed in workmanship like manner according to standard practices. All agreements
ntingent upon strikes, accidents or delays beyond our control. BUILDING EMT's Insurance coverage meets or exceeds all state, county or city
quirements. Owner to carry Fire, Tornado and other necessary insurance, including builder's risk at owner's expense, if requested. if the owner
innot purchase a builders risk policy within 10 days of acceptance, BUILDING EMTs will purchase said policy and add the cost to the contract.
The property owner, unless otherwise specified, grants BUILDING EMTs the right to post a yard sign In the front yard and use the home address,
i well as photos of the property, for marketing purposes on flyers, emalis or our website.
CEPTANCE OF PROPOSAL: The above prices, specifications, terms and conditions are satisfactory and are hereby accepted. BUILDING EMT. -
authorized to do the work as specified. Payment will be made as outlined above. Heavy trucks and equipment may be used to remove old roofing
aterials and deliver new materials, any damage to sidewalks, driveways, or lawn will be the responsibility of the homeawner. Interest on past due
ims shall accrue from the due date at the highest rate allowable under Florida law. In any legal actions brought for enforcement or interpretation of
Is agreement, the prevailing party shall also recover all costs Including reasonable attorney fees.
of Proposal: 1112712015 BUILDING EMT's Signature: of Acceplance: /,I
1,91( S Customer Building EMT's
LLC * 7025 CR 46A, Suite 1071 #433 * Lake Mary, Florida 32746 P: 800.854.
7663 * F: 800.532.9597 www.BuildingEMTs.com
The Arbors at Hidden LakZ-&;
Building Sq Ft Price
101 11088.50 2,342.46
103 1088.5 2,342.46
107 11184 5,000.00
109 11184 5,000.00
111 11184 5,000.00
112 11581 6,804.62
118 1,212 5,216.45
121 1,147.33 4,938.12
127 1,147.33 4;938.12
129 1,147.33 4,938.12
131 S03.66 3,458.98
133 803:66 3,458.98
135 80166 3,458.98
200 991.5 3,847.34
202 991.5 3,847.34
204 991.5 3,847.34
206 991.5 3,847.34
207 1132 4,872.13
215 1223 11,965.10
219 1390 5,982.56
225 1390 51982.56
Total Price: $101,089.00
a ...,r .]Rain acrlf !dull loll
THIS INSTRUMENT PREPARED BY:
Name: QY' MARY;°NNE NORSEr SEMINOLE COUNTYm+c
CLERK OF CIRCUIT COURT ,'.t COMPTROLLERAddress:
q'
l(7yr 1•.S/(C•i/L 4\apl
2.^;-+ry}i(L1
p _ [ 1310 7t icf' .ilsai.+f-1 t e 41-1 '1.,i LEI+ uu 1 g (1p3s )
V CLERK'S 4 2016009990
RECORDED 01/20/'016 03:00a00 P11NOTICEOFCOMMENCEMENTRECORDINGFEESi11.l.06
RECORDED BY hdevore
State of Florida
County of Seminole
n
Permit Number: Parcel ID Number:' ' - ` t'?F 00 — (`
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with
Chapter 713', Florida Statutes, the following information is provided in this Notice of Commencement.
DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available)
GENERAL DESCRIPTION OF IMPROVEMENT:
OWNER}ARM) TI N:
j (
Name.. i e- 1 f9acs ( I C.%' IL't11i1(+l E(1 S NSLC;a{it)N) I(ie
Address:
Fee Simple Title Holder (if other than
CONTRACTOR:
Name:
Address:
Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served
as provided by ction 713.13(1)(b), Flo td tatutes. j
Name: — i 11. c8ar GG en L4ti d-miqunoie[ AsurIicaim., /tie 10/1) Rd4wids-ol1 elifcffils Address:
In
addition to himself, Owner Designates of To
receive a copy of the Lienor s Notice as Provided in Section
713.13(1)(b), Florida Statutes. Expiration
Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different
date is specified) WARNING
TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA
STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.
IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under
penalties of erjury, I declare that 1 have read the foregoing and that the facts stated in it are.ttue',` ,,'-; t+, to
the best of my no dge a d elief. oyme
Owner's Printed Name Florid
1 3(1)( o st sign the notice of commencement and no one Ise maybe permitted to sign in his or her slead«? o y t — ,
u c
coState
of f County ofThe
foregoinginstrumentwasacknowledgedbeforemethisUdayofrTYlUkp' (-L A . 20 b
G % c
y
C1 t 1 e-- ,Who is personally known to me ¢ t= Namof
erson making statement OR
who has produced identification type of identification produced: r
ke
V;u'e',, Judah Burton 2"X/ 2° ` = Commission # FF937650 Expires: November
19, 2019 to Signa[u Bonded thru
Aaron Notary frntu"
Technical Data Sheet
XTTm 30 Shingles
XTTm 25 Shingles
CT20Tm Shingles
PRODUCT INFORMATION
CertainTeed offers a variety of three -tab shingle products that
combine exceptional durability with flexibility for better resistance to
blow -off. In addition to their suitability for residential applications,
these products are ideal for commercial applications. Available in
English" dimensions —12" x 36" and in "Metric" dimensions —13 1/4"
x 39 3/8", depending on the product and sales region.
Algae Resistant (AR) versions of these shingles are available in some regions. Algae resistant shingles
help protect against staining or discoloration caused by algae.
Colors: Please refer to the product brochure or CertainTeed website for the colors available in your
region.
Limitations: Use on roofs with slopes greater than 2" per foot. Low slope applications (2" to 4" per foot)
require additional underlayment. In areas where icing along the eaves can cause a backup of water,
apply CertainTeed WinterGuardTM Waterproofing Shingle Underlayment, or its equivalent, according to
application instructions provided with the product and on the shingle package.
On slopes greater than 21" per foot, apply a spot of roofing cement under each shingle tab corner
according to application instructions provided on the shingle package.
Product Composition: These shingles are composed of a fiber glass mat base. Ceramic -coated mineral
granules are tightly embedded in carefully refined, water-resistant asphalt. These shingles have self-
sealing adhesive. These are 3-tab shingles.
Applicable Standards:
ASTM D3018, Type I
ASTM D3462
ASTM E108 Class A Fire Resistance
ASTM D3161 Class F Wind Resistance
ASTM D7158 Class H Wind Resistance
UL 790 Class A Fire Resistance
ICC-ES Evaluation Report ESR-1389
ICC-ES Evaluation Report ESR-3537
CSA Standard A123.5 (except CT20 & XT 25 English)
Florida Product Approval # FL5444
Miami -Dade Product Control Approved (Regional)
Technical Data: XT 30 — English
Weight/Square (approx.): 215 Ibs
Dimensions (overall): 12" x 36"
Shingles/Square: 80
Weather Exposure: 5"
XT 25 — English XT 25 — Metric
Weight/Square (approx.): 205 Ibs 220 Ibs
Dimensions (overall): 12" x 36" 13-114" x 39-3/8"
Shingles/Square: 80 65
Weather Exposure: 5" 5-5/8"
CT 20 — English CT 20 — Metric
Weight/Square (approx.): 195 Ibs 195 Ibs
Dimensions (overall): 12" x 36" 13-1/4" x 39-3/8"
Shingles/Square: 80 65
Weather Exposure: 5" 5-5/8"
Technical Data Sheet (Continued)
Strip Shingles Page 2 of 3
INSTALLATION
The following is a general summary of the installation methods. Detailed installation instructions are
supplied on each bundle of strip shingles and must be followed. Separate application sheets may also be
obtained from CertainTeed.
Roof Deck Requirements: Apply shingles to minimum 3/8" thick plywood, minimum 7/16" thick non -
veneer (E.g. OSB), or minimum 1" thick (nominal) wood decks. The plywood or non -veneer decks must
comply with the specifications of APA-The Engineered Wood Association.
Ventilation: Provisions for ventilation should meet or exceed current HUD Standards. To ensure
adequate balance ventilation, use a combination of continuous ridge ventilation (using CertainTeed Ridge
Vent products, or a comparable product with an external baffle) combined with soffit venting.
Valleys: Valley liner must be applied before shingles. The Closed -Cut valley application method is
recommended, using CertainTeed WinterGuard Waterproofing Shingle Underlayment, or its equivalent, to
line the valley prior to being fully covered by the shingles.
Underlayment:
On slopes 4" per foot or greater, CertainTeed recommends one layer of DiamondDeck"', Synthetic
Underlayment, or Roofers' SelectTm High -Performance shingle underlayment, or shingle underlayment
meeting ASTM D226, D4869 or ASTM D6757. Always ensure sufficient deck ventilation, and take
particular care when DiamondDeck or other synthetic underlayment is installed. For UL fire rating,
underlayment may be required. Corrosion -resistant drip edge is recommended and should be placed over
the underlayment at the rake and beneath the underlayment at the eaves. Follow manufacturer's
application instructions.
On low slopes (2" up to 4" per foot), one layer of CertainTeed's WinterGuard Waterproofing Shingle
Underlayment (or equivalent meeting ASTM D1970) or two layers of 36" wide felt shingle underlayment
Roofers' Select High -Performance Underlayment or product meeting ASTM D226, D4869 or ASTM
D6757) lapped 19" must be applied over the entire roof, ensure sufficient deck ventilation. When
DiamondDeck or other synthetic underlayment is installed, weather -lap at least 20" and ensure sufficient
deck ventilation. When WinterGuard is applied to the rake area, the drip edge may be installed under or
over WinterGuard. At the eave, when WinterGuard does not overlap the gutter or fascia, the drip edge
should be installed under WinterGuard. When WinterGuard overlaps the fascia or gutter, the drip edge or
other metal must be installed over it. Follow manufacturer's application instructions.
Fastening: Four nails are required per shingle. For English -sized shingles they are to be located 5/8"
above the top of each cutout and 1" and 12" in from each side of the shingle. For Metric -sized shingles
they are to be located 1" and 13-1/8" in from each side of the shingle. They must be of sufficient length to
penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to be 11
or 12 gauge, corrosion -resistant roofing nails with 3/8" heads.
On steep slopes greater than 21" per foot, apply a spot of roofing cement under each shingle tab comer
according to application instructions provided on the shingle package.
Application (English -Sized Shingles): The recommended application method is the Six -Course, 6"
Stepped -Off Diagonal Method found on each bundle of shingles. These shingles may also be applied
using the 5" Stepped -Off Diagonal Method, or the 6" Offset, Single -Column Vertical -Racking Method,
instructions for which may be obtained from CertainTeed. These shingles may be used for new
construction or for re -roofing over old shingles.
Technical Data Sheet (Continued)
Strip Shingles Page 3 of 3
Application (Metric -sized shingles): The recommended application method is the Seven Course, 5-5/8"
Stepped -Off Diagonal Method found on each bundle of shingles. These shingles may also be applied
using the Eight Course, 5 Stepped -Off Diagonal Method or the Half -Tab Diagonal Method, instructions
for which may be obtained from CertainTeed. These shingles may be used for new construction or for
reroofing over old shingles.
Flashing: Use corrosion -resistant metal flashing.
Hips and Ridges: Use field shingles of a like color for capping hips and ridges.
MAINTENANCE
These shingles do not require maintenance when installed according to manufacturer's application
instructions. However, to protect the investment, any roof should be routinely inspected at least once a
year. Older roofs should be looked at more frequently.
WARRANTY
XT 30 (and AR), shingles carry a 30-year limited transferable warranty, XT 25 (and AR) carry a 25-year
limited transferable warranty, and CT 20 (and AR), shingles carry a 20 year limited transferable warranty
to the consumer against manufacturing defects. All of these shingles carry 5-year SureStart protection
except for CT 20 which carries 3-year SureStart protection. For specific warranty details and limitations,
refer to the warranty itself (available from the local supplier, roofing contractor or on-line at
www.certainteed.com).
FOR MORE INFORMATION
Sales Support Group: 800-233-8990
Web site: www.certainteed.com
See us at our on-line specification writing tool, CertaSpec, at www.certainteed.com/certaspec.
CertainTeed Roofing
P.O. Box 860
Valley Forge, PA 19482
Copyright CertainTeed Corporation, 2015
All rights reserved. Updated: 05/2015
z s Q a
42 V.1 12 $ors y,tt,
SAINT-G•: