Loading...
HomeMy WebLinkAbout211 E 22 StIV - BY: a CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: L Co-i`A3qa Documented Construction Value: $ _3::_qq C30 Job Address:` S_evFC__-11_4 11 z Historic D'strict: Yes No Parcel ID: Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: 11:1 a7 Namej Property Owner Information - /' r 1 m Phone: ( t/ 6o,4/. Streew/// Resident of property? : - City, State Zips_ a 2 Contractor Information Name ; ( t' Phone: D"l> —I 3 Street: Fax: City, State Zip: \ State License No.: C G:c, Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5`h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Agent i jZ1lf% tl,Print Contractor/Agent's Name vote Thedis coral Acevedo NOTARY PUBLIC STATE OF FLORIDA Caxnm# F-F90179ry9 ( Owner/Agent i Personably I wn3 o Me or Produced ID Type of ID Keu'i Leigh Ordor" NOTARY PUBLIC STATE OF FLORIDA CCa,,n,,,m## FF226786g Contractor/AgeP!s `"PeTs5d aljQy Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ff Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads JC)(Ac- APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: 54=' Revised: June 30, 2015 Permit Application Renewal Itemized Order Receipt byAndersen. dba: Renewal by Andersen of Central Florida Cheryl Sandman j Legal Name: Universal Roofing Group inc. 211 E 22st / Po Box 806 Sanford FI 32772 sos CGC1523333 Sanford, FL 32771 w1soow RE LACEMENT 5606 Carder Rd. I Orlando, FL 32810 C: (714)466-0242 Phone: 4078034722 1 Fax: I jim@rbafla.com 101 Kitchen Tr (Y-- Window: Double -Hung, Equal, Fume, ..l.raditional Checkrail, EXTERIOR White, INTERIOR White, Glass: Sash All: High Performance, o Pattern, Hardware: White, Screen: TruScene with Exterior Color Match, Full Screen, Grille Style: No Grilles, Misc: Non 105 Living room TY'"Yr Window: Gliding - Double, Gliding, 1:1, Active / Stationary, Base Frame, EXTERIOR White, INTERIOR White, Glass: Sash All: Igh P ce. o Pattern, Hardware: White, Screen: TruScene with Exterior Color Match, Half Screen, Grille Style: T K e —} No Grilles, Misc: Non 106 Livingroom L T`1"VV\ Window: Gliding - Double, Gliding, 1:1, Stationary / Active, Base Frame, EXTERIOR White, INTERIOR White, Glass: Sash All: 73 X99 rg Per orrrrnc , o Pattern, Hardware: 'White, Screen: TruScene with Exterior Color Match, Half Screen, Grille Style: No Grilles, Misc: Non WINDOWS: 3 PATIO DOORS: 0 SPECIALTY: 0 MISC: 0 TOTAL $3,744 g Renewal by Andersen is committed to our customers'safety by complying with the rules and lead -safe work practices specified by the EPA. 04/ 22/16 Page 4 / 11 Renewal Agreement Document and Payment Terms b Andersen. dba: Renewal by Andersen of Central Florida Cheryl Sandman Legal Name: Universal Roofing Group inc. 211 E 22st / Po Box 806 Sanford FI 32772 CGC1523333 Sanford, FL 32771 WINDOW NE LACEMENT 5606 Carder Rd. I Orlando, FL 32810 C: (714)466-0242 Phone: 4078034722 1 Fax: I jim@rbafla.com Customer(s) Name: Cheryl Sandman Contract Date: 04/22/16 Customer(s) Street Address: 211 E 22st / Po Box 806 Sanford Fl 32772, Sanford, FL 32771 Primary Telephone Number: Secondary Telephone Number: (714)466-0242 Primary Email: Secondary Email: Buyer(s) hereby jointly and severally agrees to purchase the products and/or services of Universal Roofing Group inc. d/b/a Renewal by Andersen of Central Florida("Contractor"), in accordance with the terms and conditions described in this Agreement Document and Payment Terms, Notice of Cancellation, Itemized Order Receipt, Terms and Conditions of Sale, Sales Cost Savings Program (SCSP), Lead - Safe Form, What to Expect, Release Agreement, and any other document attached to this Agreement Document, the terms of which are all agreed to by the parties and incorporated herein by reference (collectively, this "Agreement"). Buyer(s) hereby agrees to sign a completion certificate after Contractor has completed all work under this Agreement. Total Job Amount: $3,744 By signing this agreement, you acknowledge that the Balance Due, and the Amount Financed must be made by personal check, bank check, credit card, or cash. Deposit Received: $350 Balance Due: $3,394 Estimated Start: Estimated Completion: Amount Financed: $3,394 08/01/2016 09/05/2016 Method of Payment: Credit Card We schedule installations based on the date of the signed contract and secondarily on Financing the date in which we complete the technical measurements. The installation date that we are providing at this time is only an estimate. We will communicate an official date Notes: and time at a later date. Rain and extreme weather are the most common causes for delay. Buyer(s) agrees and understands that this Agreement constitutes the entire understandings between the parties and that there are no verbal understanding changing or modifying any of the terms of this Agreement. No alterations to or deviations from this Agreement will be valid without the signed, written consent of both the Buyer(s) and Contractor. Buyer(s) hereby acknowledges that Buyer(s) 1) has read this Agreement, understands the terms of this Agreement, and has received a completed, signed, and dated copy of this Agreement, including the two attached Notices of Cancellation, on the date first written above and 2) was orally informed of Buyer's right to cancel this Agreement. NOTICE TO OWNER: Do not sign this contract if blank. You are entitled to a copy of the contract at the time you sign. YOU, THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME NOT LATER THAN MIDNIGHT OF 04/27/2016 OR THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION, WHICHEVER DATE IS LATER, SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. Legal Name: Universal Roofing Group inc. Customer(s) dba: RenewOy ersen of CC tral Florida V Signature of Sales Person Signature Tim Stewart Cheryl Sandman Print Name of Sales Person Print Name Signature Print Name 04/22/16 Page 2 / 11 11 :lip 1I N 1l I1 ii i II THIS, INSTR KE Name: ":-ROMtl (I Address: ir ZUXy 7 llL' l C ?I NOTICEICE OF COMMENCEMENT `+ Permit Number: Parcel ID Number: 71, C { f The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRI TI QF P ERTY: .eg es r `on •f the Rroperty andistr. et addr ss iJ blei, . I 1 4. v A 1 2. GENERAL DESCRIPTION OF IMP Of E I LkJ/ 3. OWNER INFORMATIO LESSEE IN ORM TIIO^N IF LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address 11E n Interest in property: Fee Simple Title Holder (if other than owner listed above) Name: Address: pi 4. CONTRACTOR:fName: ' one Number Address: ! \ V / 5. SURETY (ff applt 'a le, a copy of the pa bond is attached): Name: Address: Amount of Bond: 6. LENDER: Name: Phone Number: Address: — 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: _ Phone Number: Address: 8. In addition, Owner designates _ of _ to receive a copy of the Lienor's Notice as: provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) __ WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. 1 Sig ature of Owner or Lessee, orlOwners or Lessee's Authorized Officer/Director/Partner/Manager) l Print Name and Provide signatory's Title/Office) R State of_County of _y' ct The foregoing instr men , 'as ackno edgd` before meFthis day ofg — r by Jl ? f ' ' r, . % ! .. Who is personally known to me El OR h;ani, +pe,s n r. kirg sraiFm nt +r.% s a . .: •-. ;1 who has produced identifiration n' L:\z`• i'v (.+ii.wo !r._i,._.+l ft ' AUG 16 2016 dent ficatio.? pncl::rs::: C' RiIFfEDCOPY— MARYANNE RIIOAFS CLERK 0" T CIRCUIT COURTAND ri'. > t 5E I tf`v. •....... Y DEPUTY CLERK POWER OF ATTORNEY I hereby name and appoint Joan Mellick Of Universal Roofing Group, Inc. to be my lawful attorney in fact To act for me and apply to the Building Department for a Building permit for work to Be performed at a location described as: Section: 36 Township: 0 Range: 3b Lot:, Block:Oo5<n6 -- -f6, D Subdivision: I'r1 '5, a a d S+, Address of job) peVL4 Owner of property and address) And to sign my name and do all things necessary to this appointment. Mellick Contractor) The foregoing instrument was acknowledged before me this akz iQ By Jared Mellick Who is personally know to me and who did not take an oath. State of Florida County of Orange Notary) My Commission expires: Commission#: Thalia Coral Acevedo Q, NOTARY PUBLIC a 7+STATE OF FLORIDA y ? Comm# FF901799 s97* 1'* Expires 7/21/2019 RECORD COPY REVIEWED POR CODE COMPLIANCE PLANS EXAMINER DATE SANFORD BUILDING DIVISION APERMIT ISSUED SHALL BECONSTRUED TOBEA LICENSE T0PROCEED WITH THE WORK AND NOT AG L)THORVfT0VIOLATE, CANCEL, ALTER 0RSET 3[DEA0YTF-THEPROV}S| ONS-OFTMETEC-HN|c-AL- 00DEG.N0RSHALL |SGUANCEOFAPERMITPREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING ACORRECT|0NOFERRORS |NPLAN8. CONSTRUCTION ORV| OL&T|0NS0FTH\GCODE 6fl 6_239 2 5/31/2016 Florida Building Code Online FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL19563-RO New 2014 Approved Andersen Corporation 100 Fourth Avenue North Bayport, MN 55003 651) 264-5308 alan.barstad@AndersenCorp,com Alan Barstad a la n, ba rstad @Ande rsenCorp, co m Windows Horizontal Slider w\LDIA U 16"2392 Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Hermes F. Norero, P,E. PE-73778 Window and Door Manufacturers Association 12/31/2019 Locke Bowden v Validation Checklist - Hardcopy Received FL19563 RO COI COI Andersen SS 2015-08-31 odf Standard AAMA/WDMA/CSA 101/I.S.2/A440 AAMA/WDMA/CSA 101/I.S.2/A440 Year 2008 2011 file:IIIC:lUserslthali aiD ocum ents/Product%20Approval s/Renewal%20by%20Anderson%20Slider%20Product%20Approval.htm I 112 I INSTALLATION NOTES: 1. INSTALLATION CLIPS: ONE III INSTALLATION ANCHOR CLIP IS REQUIRED AT EACH ANCHOR LOCATION SHOWN, EACH CLIP IS TO USE TWO (2) INSTALLATION ANCHORS. 2. THROUGH FRAME AND NAIL FIN: ONE (1) INSTALLATION ANCHOR 15 REQUIRED AT EACH ANCHOR LOCATION SHOWN, UNLESS OTHERWISE NOTED, 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF±112 INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (1. E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. INSTALLATION CLIP: FOR INSTALLATION THROUGH 1X BUCK TO CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/MASONRY, USE TWO (2) 3116 INCH HWH ITW TAPCON PER INSTALLATION CLIP OF SUFFICIENT LENGTH TO ACHIEVE 1 314 INCH MINIMUM EMBEDMENT AND SHALL MAINTAIN MINIMUM 2" EDGE DISTANCE. S. INSTALLATION CLIP: FOR INSTALLATION INTO 2X BUCK USE TWO (2) #8 PAN HEAD WOOD SCREWS PER INSTALLATION CLIP OF SUFFICIENT LENGTH TO ACHIEVE 1 1121NCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. S. INSTALLATION CLIP: FOR INSTALLATION THROUGH METAL STUD USE TWO (2) #8 HWH GRADE 5 SELF -DRILLING OR SELF -TAPPING SCREWS PER INSTALLATION CLIP OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 7. THROUGH FRAME: FOR INSTALLATION INTO 2X BUCK USE #10 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 8, THROUGH FRAME: FOR INSTALLATION INTO METAL SUBSTRATES USE #10 GRADE 5 SELF -DRILLING OR SELF -TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 3THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 9. THROUGH FRAME: FOR INSTALLATION THROUGH 1X BUCK TO CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/MASONRY, USE ONE (1) 3116 INCH ITW TAPCON OF SUFFICIENT LENGTH TO ACHIEVE 11/4 INCH MINIMUM EMBEDMENT AND SHALL MAINTAIN MINIMUM 2" EDGE DISTANCE. 10.NAIL FIN: FOR INSTALLATION INTO 2X BUCK USE #8 PAN HEAD WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1 112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 11.NAIL FIN: FOR INSTALLATION INTO METAL SUBSTRATES USE #8 HWH GRADE 5 SELF -DRILLING OR SELF -TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 12.MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 13.INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 14.FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE D15TANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 15.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 16.INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. C. MASONRY- STRENGTH CONFORMANCE TO ASTM C-90 D. STEEL- MINIMUM YIELD STRENGTH OF 33 KSL MINIMUM WALL THICKNESS OF 48 MILS(18 GAUGE). E. ALUMINUM -MINIMUM WALL THICKNESS OF %", 6063-TS ALLOY OR BETTER. RENEWAL SERIES GLIDER WINDOW NON -IMPACT GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 5TH EDITION (2014) FLORIDA BUILDING CODE, EXCLUDING HVHZ. THE PRODUCT HAS BEEN EVALUATED TO THE FOLLOWING: AAMA/WDMA/CSA 101/I.S.2/A440-08/11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE MASOFRAMING AS A NRY, 2X AND METAL STUD MAIN WIND FORCE RESISTING SYSTEM CAPABLE WITHSTANDING AND TRANSFERRING APPLIED MI PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3, 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4, THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED TO PROTECT THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: FIBREX® AND PVC. 7, SEE SHEET 9 FOR GLAZING DETAILS. 8. DESIGNATIONS "X"AND "0" STAND FOR THE FOLLOWING: X. OPERABLE PANEL O: FIXED PANEL TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION I GENERAL h INSTALLATION NOTES 2 ELEVATIONS 3 ELEVATIONS (2) 4 NO AND XX ANCHOR LAYOUTS 5 XOX ANCHOR LAYOUTS 6 THROUGH FRAME INSTALLATION DETAILS 7 NAIL FIN INSTALLATION DETAILS 8 CLIP INSTALLATION DETAILS 9 INTERMEDIATE MEMBERS, REINFORCEMENT REQUIREMENTS AND GLAZING DETAIL DESIGN PRESSURE RATING SIZE CONFIGURATION DESIGN PRESSURE SASH WIDTH RATIO 72" X 60" XO 40.0 / -40.0 PSF 1:1 96" X 54" XO 40.0 / -40.0 PSF 1:1 96" X 72" XO 40.0 / -40.0 P5F 1:1 108" X 54" XO 25.0 / -25.0 PSF 1:2 108" X 72" XO 20.0 / -20.0 PSF 1:2 56" X 80" XO 40.0 / -40.0 PSF 1:2 74" X 54" XO 40.0 / -40.0 PSF 1:2 74" X 72" XO 35.0 / -35.0 P5F 1:2 48' X 48" XX 40.0 / -40.0 PSF 1:1 72" X 80" XX 30.0 / -30.0 PSF 1:1 96" X 54" XX 35.0 / -35.0 PSF 1:1 96" X 60" XX 35.0 / -35.0 P5F 1:1 96" X 72" XX 20.0 / -20.0 PSF I:1 144" X 54" XOX 30.0 / -30.0 PSF 1:1:1 144" X 72" XOX 25.0 J -25.0 PSF IAA 84" X 60" XOX 40.0 ! -40.0 PSF 1:1:1 84" X 80" XOX 35,0 / -35D PSF 111:1 144" X 54" XOX 30.0 / -30.0 PSF 1:2:1 144" X 72" XOX 25.0 / -25.0 PSF 1:2:1 84" X 60" XOX 40.0 / -40.0 P5F 1:2:1 84" X 80" XOX 35.0 / -35.0 PSF 1:2:1 wl. eews-Doane 100 FOURTH AVE NORTH BAYPORT, MN 55003-1096 PH: ( 651) 264-5150 FX: (651) 264-5185 N m MM10 p Z # v 10ZO' H m ~ ~ Q Z6A3aso0Zu wa Q 3toWdm w 3 a Lu ix J m W r1 H- Qv/ Z O N r H W V) V) CL W LL y-. , F- I N I N V I V) Z I Digitally signed by Hermes F Norero, P,E, A YV DO 7 i Reason: I am approving this document SHEET: Date: 2015.12.18 19:58:55 -05'00' 1 OF 9 UNIT M MAX. D. HEIGHT HE: 72" ! L A HE UNIT MAX. WIDTH 96" 1:1 SASH RATIO WIDTH 96" MAX. D.L.O. MAX. D.L.O. 4315/16" — 4315/16.1 -- A A A 6 7 8 C A 8 9 VIT MAX. SAX. D.L.O. IGHT HEIGHT X" r2" 65" 1:1 SASH RATIO ry r L A HE WIDTH 108" MAX. D.L.O. MAX. D.L.O. 33 5/16" 66 3/8" A A A 6 7 8 C e B 9 VIT MAX. SAX. D.L.O. IGHT HEIGHT 65" U A HE vv B B NOTE: 6 7 8 ALTERNATE MEETING STILE LOCATIONS MAY BE USED SUCH THAT ELEVATION MAX. DLO DIMENSIONS SHOWN 108" X 72" XO UNIT HEREIN ARE NOT EXCEEDED. UNEQUAL 1:2 SASH RATIO SASH RATIO NOT AVAILABLE FOR ACTIVE/ACTIVE(XX) UNITS. UNIT MAX. WIDTH 72" MAX. D.L.O. MAX. D.L.O. _ 3115/16" r 3115/16" 6 ELEVATION 72" X 80" XX UNIT 1:1 SASH RATIO wlxoowe•oo RRs tW FOURTH AVE NORTH BAYGORT. MN'55 34M PH: (651)264-5M FX.(651j 264-54B5 m A N Z a O0 a O O u x vu > m< Q w m Z N mHZG mNa J w m W 0 n m a ix m x 2 O i uZ U - DWG #: AWD095 SHEET: 2 OF 9 UNIT MAX. MAX. D.L.O. HEIGHT HEIGHT 80' 73" UNIT MAX. WIDTH 84" MAX. MAX. MAX. D.L.O. D.L.O. — D.L.O. — 24 511" 5/8" 24 5/8" 84 ELEVATION 84" X 80" XOX UNIT 1:1:1 SASH RATIO UNIT MAX. WIDTH 84" MAX. MAX. MAX. D.L.O. D.L.O. D.L.O. 18 7/16" 36 7/8" 11 18 7/16" UNIT MAX. WIDTH 144" MAX. D.L.O. MAX. D.L.O. MAX. D.L.O. 44 5/8" 44 5/8" - 44 5/8" A A A b 7 8 JX. UNIT MW"""X. MAX. DHEIGHTHE72" g 9 9 8 UNIT MAX. MAX. D.L.O. UNIT H HEIGHT HEIGHT MAX. D 80" 73" HEIGHT HE 72" L I B B B 6 7 8 ELEVATION 84" X 80" XOX UNIT 1:2:1 SASH RATIO b 7 8 NOTE: RTE MEETINGoATIONSELEVATIONMAYBE USEDLE 144" X 72" XOX UNIT SUCH THAT MAX. DLO 1:1:1 SASH RATIO DIMENSIONS SHOWN HEREIN ARE NOT EXCEEDED. UNIT MAX. WIDTH 144" ELEVATION 144" X 72" XOX UNIT 1:2:1 SASH RATIO W IR OOWa•000 Ra 100 FOURTH AVE NORTH BAYPORT, MN 55003-1096 PN:(651) 26.5150 W (651) 26e-5485 a0M w M f V # v a Z68J1M V1 1N N m m 0 L x cax w m zHm 3 u w ow ozaNazLllWa rnmlLLu r1 WF m day.., • F H ^'>ca hz mwF- n v:* Nz A0 DWG #: AW0095 SHEET: 3 OF 9 MAX. O.C. SPACING SEE SCHEDULE CORNER DIST. SEE SCHEDULE MAX. O.C. SPACING SEE SCHEDULE TWO INSTALLATION ANCHORS (SEE INSTALL NOTES 7-9, SHEET 1) AT MEETING STILE END LOCATIONS THROUGH HEAD, SPACED 2.5" ON EACH SIDE OF MEETING STILE CORNER DIST. SEE SCHEDULE TYPICAL ANCHOR LAYOUT XO OR OX GLIDER 1:1 SASH RATIO TWO INSTALLATION ANCHORS (SEE MAX. O.C. SPACING INSTALL NOTES 7-9, SHEET 1) AT SEE SCHEDULE MEETING 571LE END LOCATIONS THROUGH HEAD, SPACED 2.5" ON CORNER DIST. EACH SIDE OF MEETING STILE SEE SCHEDULE i MAX. O.C. SPACING SEE SCHEDULE T CORNER DIST. SEE SCHEDULE TYPICAL ANCHOR LAYOUT XO GLIDER ALL METHODS OF INSTALLATION 1:2 SASH RATIO REQUIRE A CONTINUOUS 2 BEAD OF SILICONE BELOW THE SILL RENEWAL SERIES GLIDER ANCHOR SPACING FROM MAX O.C. MAX O.C. MAX O.C. INSTALLATION CONFIG. CORNERS HEAD SILL JAMBS METHOD IN) IN) IN) IN) O NAILFIN 3.5 3.5 3.5 3.5 F s c INSTALLATION 5.5 15.25 15.25 16 CLIP X THROUGH SEE 5.5 10,125 15.25 NOTES O NAIL FIN 3.5 3.5 3.5 3.5 H c INSTALLATION 165.5 15 15 00. CLI P X ry THROUGH SEE 5.5 11.25 17.25 FRAME NOTES z F NAIL FIN 3.5 3.5 3.5 3.5 O y INSTALLATION 5.5 14.5 14.5 16 x N CLIP O .. x 'i THROUGH SEE FRAME 5.5 10.375 NOTES 21.5 w 0 NAIL FIN 3.5 3.5 3.5 3.5 G INSTALLATION 5.5 12.125 12.125 16 x CLIP X Ai THROUGH SEE FRAME 5.5 10.5 NOTES 22 INSTALLATION NOTES: FOR THROUGH FRAME INSTALLATIONS, PRODUCT COMES WITH PRE -DRILLED INSTALLATION ANCHOR HOLES, USE ALL PRE -DRILLED HOLES WHEN INSTALLING. IF AFTER PLACING ANCHORS THROUGH ALL PRE -DRILLED HOLES THE MAXIMUM SPACING REQUIREMENTS IN THE ABOVE TABLE ARE NOT MET, ADD ADDITIONAL ANCHORS INSTALLED THROUGH THE FRAME TO MEET SPACING REQUIREMENTS. FOR THROUGH FRAME INSTALLATIONS, INSTALLATION CLIPS MUST BE USED AT THE SILL IN LIEU OF FASTENERS THROUGH FRAME, SPACED IN ACCORDANCE WITH THE INSTALLATION CLIP SPACING REQUIREMENTS LISTED IN THE ABOVE TABLE. FOR CUSTOM SASH RATIOS, USE WORST CASE ANCHOR SPACING BETWEEN EQUAL SASH AND 1:2 OR 1:2:1 SASH RATIOS FROM TABLE ABOVE. REFER TO SHEET 1, INSTALLATION NOTES 4-11 FOR ANCHOR TYPE DEPENDENT ON INSTALLATION METHOD AND SUBSTRATE. W INOOWf•000 Rf 100 FOURTH AVE NORTH 8 YPORT, MN 55 34M PH: (651)264.5M M (651) 264-5485 m M 1 M n o p ZugH4TO J 1 M w o p 2 X w Z d w V 1n < m< a x m ZLu Qm LL Z p p Q N Z Q o Q a d muio m W of p LL y' i di m m n W I m Z YLn H p V N = Z p V DWG #: AW0095 SHEET: 4 OF 9 CORNER DIST. SEE SCHEDULE MAX. O.C. SPACING SEE SCHEDULE I TWO INSTALLATION ANCHORS (SEE INSTALL NOTES 7-9, SHEET 1) AT MEETING STILE ENO LOCATIONS THROUGH HEAD, SPACED 2.5' ON MAX. O.C. SPACING EACH SIDE OF MEETING STILE SEE SCHEDULE CORNER DIST. SEE SCHEDULE TYPICAL ANCHOR LAYOUT XOX GLIDER 1:1:1 SASH RATIO TWO INSTALLATION ANCHORS (SEE MAX, O.C. SPACING INSTALL NOTES 7-9, SHEET 1) AT SEE SCHEDULE MEETING STILE END LOCATIONS THROUGH HEAD, SPACED 2.5' ON CORNER DIST, EACH SIDE OF MEETING STILE SEE SCHEDULE ~ I7 i MAX. O.C. SPACING SEE SCHEDULE 1 - CORNER DIST. SEE SCHEDULE ALL METHODS OF INSTALLATION REQUIRE A CONTINUOUS 1z" BEAD OF SILICONE BELOW THE SILL TYPICAL ANCHOR LAYOUT XOX GLIDER 1: 2:1 SASH RATIO RENEWAL SERIES GLIDER ANCHOR SPACING FROM MAX O.C. MAX O.C. MAX O.C. INSTALLATION CONFIG. CORNERS HEAD SILL JAMBS METHOD IN) IN) IN) IN) O NAILFIN 3.5 3.5 3.5 3.5 ee o INSTALLATION 5. 5 15.25 15.25 16 GCLIP x THROUGH SEE 5. 5 10.125 15.25 FRAME NOTES O NAILFIN 3.5 3.5 3.5 3.5 K 0 = INSTALLATION 05.5 15 15 16 CUP X N THROUGH SEE 5. 5 11.25 17.25 FRAME NOTES NAIL FIN 3.5 3.5 3.5 3.5 W 0N INSTALLATION 5. 5 14.5 14.5 16 k va CLIP x . 4 THROUGH SEE e4 FRAME 5. 5 10.375 NOTES 21. 5 Cc NAILFIN 3.5 3.5 3.5 3.5 Q QCKINSTALLATION 5. 5 12.125 12.125 16 x CLIP O .+ THROUGH SEE FRAME 5. 1 10.5 I NOTES 22 INSTALLATION NOTES: FOR THROUGH FRAME INSTALLATIONS, PRODUCT COMES WITH PRE - DRILLED INSTALLATION ANCHOR HOLES, USE ALL PRE - DRILLED HOLES WHEN INSTALLING. IF AFTER PLACING ANCHORS THROUGH ALL PRE -DRILLED HOLES THE MAXIMUM SPACING REQUIREMENTS IN THE ABOVE TABLE ARE NOT MET, ADD ADDITIONAL ANCHORS INSTALLED THROUGH THE FRAME TO MEET SPACING REQUIREMENTS. FOR THROUGH FRAME INSTALLATIONS, INSTALLATION CLIPS MUST BE USED AT THE SILL IN LIEU OF FASTENERS THROUGH FRAME, SPACED IN ACCORDANCE WITH THE INSTALLATION CLIP SPACING REQUIREMENTS LISTED IN THE ABOVE TABLE. FOR CUSTOM SASH RATIOS, USE WORST CASE ANCHOR SPACING BETWEEN EQUAL SASH AND 1:2 OR 1:2:1 SASH RATIOS FROM TABLE ABOVE. REFER TO SHEET 1, INSTALLATION NOTES 4-11 FOR ANCHOR TYPE DEPENDENT ON INSTALLATION METHOD AND SUBSTRATE. r w1• oows•eooRs 100 FOURTH AVE NORTH BA RT. MN 55003-1096 PH( 651)264-5150 FX: (651) 264-5485 w M4 W n U # v S Z 6 8 OT N m M a H 5 pv zma JZTWm Q m M H< m X p p 2 N o, Z oX a < <^ J K d mWp a^ Lu m L $ J m p LL W ^. co m Ul J N I- _ m Z y 1n < F p N 3 2: N Z n v AWN SHEET: 5 OF CONCRETE/MASONRY BY OTHERS CAULK BETWEEN CONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS 1/4" MIN, EDGE DISTANCE 2X WOOD BUCK BY OTHERS 1 1/2" MIN. EMBEDMENT 10 WOOD SCREW INSTALLATION ANCHOR 1/4" MAX. EXTERIOR FINISH SHIM SPACE BY OTHERS PERIMETER SEALANT TWO INSTALLATION ANCHORS (SEE BY OTHERS INSTALL NOTES 7-9, SHEET 1) REQUIRED O.A. WINDOW THROUGH FRAME AT HEAD ADJACENT TO HEIGHT MEETING STILES, TYPICAL EDGE DISTANCE AND EMBEDMENT REQUIRED O.A. WINDOW HEIGHT EXTERIOR ` INTERIOR SEE &LA -ZING DETAIL A VERTICAL SECTION 6 HEAD .2X WOOD BUCK THROUGH FRAME EXTERIOR PERIMETER SEALANT BY OTHERS ONE (1) #8 SCREW, PER CLIP, FROM CLIP TO WINDOW FRAME EXTERIOR FINISH BY OTHERS IX WOOD BUCK—,"' OPTIONAL) BY OTHERS CAULK BETWEENCONCRETE/MASONRY&IX WOOD BUCK BY OTHERSCONCRETE/MASONRY BY OTHERS j5E' E GLAZING DETAIL INTERIOR CONTINUOUS y" BEAD OF SILICONE ALONG ENTIRE SILL 0 1/4" MAX. r SHIM SPACE 1 1/4" MIN. EMBEDMENT J. 2" MIN. EDGE DISTANCE VERTICAL SECTION l 6 % SILL - 1X WOOD ON CONCRETE/MASONRY INSTALLATION CLIP INTERIOR SEE GLAZING DETAIL 1/4" MAX. SHIM SPACE II 3 THREAD PENETRATION BEYOND METAL FRAME 3/4" MIN. EDGE DISTANCE w woows•eoorts Itlll FOURTH AVE NORTH BAYPORT, MN 55 34M PK(651)264-5M M(651)264-54B5 m m ow z 7k pvwQ ~ 8 W LL Z C s L H S O Oof V lr o T z Q m oZ< Z Z QuwmuioJ m w 0 10 SELF -DRILLING SCREW INSTALLATION ANCHOR Z METAL SUBSTRATE BY OTHERS Q SEE INSTALLATION NOTE #14, SHEET 1) H Z EXTERIOR SHEATING BY OTHERS EXTERIOR FINISH BY OTHERS PERIMETER SEALANT BY W uV) w OTHERS CY O.A. WINDOW f WIDTH TWO (2) 3/16" ITW TAPCON INSTALLATION ANCHORS SEE SHEET 8 FOR INSTALLATION CLIP DETAILS AND ANCHORING REQUIREMENTS. HORIZONTAL SECTION 6 JAMB - METAL FRAME SUBSTRATE THROUGH FRAME WG #: AW0095 iHEET: 6 OF 9 3 THEADS PENETRATION BEYOND METAL FRAME SHEATHING & METAL 3/4" MIN. EDGE STUD BY OTHERS DISTANCE 8 H WH GRADE 5 SELF -DRILLING CAULK BETWEEN INSTALLATION ANCHORS FIN & METAL STRUCTURE I/4" MAX. EXTERIOR FINISH SHIM SPACE BY OTHERS t PERIMETER SEALANT TWO INSTALLATION ANCHORS (SEE BY OTHERS INSTALL NOTES 7-9, SHEET 1) REQUIRED O. A. WINDOW THROUGH FRAME AT HEAD ADJACENT TO HEIGHT MEETING STILES, TYPICAL EDGE DI5TANCE AND EMBEDMENT REQUIRED SEE GLAZING DETAIL EXTERIOR INTERIOR VERTICAL SECTION INTERIOR 7 HEAD - METAL FRAME SUBSTRATE NAIL FIN NAIL FIN/FLANGE I5 REVERSIBLE, SEE ORIENTATION DIFFERENCE IN DETAIL A AND B GLAZING DETAIL EXTERIOR INTERIOR CONTINUOUS Y2" BEAD OF O. A. WINDOW SILICONE ALONG ENTIRE SILL HEIGHT o 0 1/ 4" MAX. PERIMETER SEALANT SHIM SPACE BY OTHERS 1 EXTERIOR FINISH 3/4" MIN. EDGE BY OTHERS DISTANCE CAULK BETWEEN FIN & 2X WOOD BUCK 8 PAN HEAD WOOD SCREW 2X WOOD BUCK INSTALLATION ANCHOR BY OTHERS CAULK BETWEEN 11/2" MIN. CONCRETE/ MASONRY & 2X EMBEDMENT WOOD BUCK BY OTHERS CONCRETE/ MASONRY BY OTHERS B VERTICAL SECTION 7 SILL - 2X WOOD BUCK NAIL FIN SEE GLAZING DETAIL EXTERIOR 1 wlx oows•eooss 100 FOURTH AVE NORTH BAYPORT. MN 55003-1096 PK( 651)264-5150 FX: (651) Z64-5 M m Mm m Y w Z # v $ 0N V1 w w Z2 0_ i R n 3/ 4" MIN. EDGE vwi < m < LL DISTANCE e Z On Z N m 1/ 4" MAX. 3 o o z SHIM SPACE z o z WOODSTRUCTUREBYOTHERSii3w ., a m w a a 8 PAN HEAD WOOD SCREW F' w m INSTALLATION ANCHOR aEy m a Q p 1 1/2" MIN. EMBEDMENT T mCAULK BETWEEN Z FIN & 2X WOOD BUCK EXTERIOR FINISH BY OTHERS O Z PERIMETER SEALANT BY a+ OTHERS H a O. A. WINDOW > ix vWIDTH w (n C) HORIZONTAL SECTION 7 JAMB - WOOD BUCK NAIL FIN otyj 1- 1riZ Y < a 3 ^ =i Uz 143uDWG #: AWD095 SHEET: 7 OF 9 CAULK BETWEEN CONCRETE/MASONRY A 2X WOOD BUCK BY OTHERS CONCRETE/MASONRY BY OTHERS 2X WOOD BUCK BY OTHERS EXTERIOR FINISH BY OTHERS 1 PERIMETER SEALANT IE BY OTHERS O.A. WINDOW HEIGHT I EXTERIOR ONE (1) #8 SCREW, PER CLIP, FROM CLIP TO WINDOW FRAME 3/4" MIN. EDGE DISTANCE TWO (2) #8 WOOD SCREW INSTALLATIONII ANCHORS PER CLIP 1 112" MIN. EMBEDMENT 1 L/4" MAX. SHIM SPACE TWO INSTALLATION ANCHORS (SEE INSTALL NOTES 7-9, SHEET 1) REQUIRED THROUGH FRAME AT HEAD ADJACENT TO INTERIOR MEETING STILE5, TYPICAL EDGE DISTANCE- AND EMBEDMENT REQUIRED... SEE GLAZING DETAIL A) VERTICAL SECTION 8 HEAD -2XWOOD BUCK INSTALLATION CLIP EXTERIOR / O.A. WINDOW HEIGHT _R PERIMETER SEALANT BY OTHERS ONE (1) #8 SCREW, PER CLIP, FROM CLIP TO WINDOW FRAME EXTERIOR FINISH BY OTHERS 1X WOOD BUCK OPTIONAL) BY OTHERS CAULK BETWEEN SEE GLAZING DETAIL INTERIOR CONTINUOUS y" BEAD OF SILICONE ALONG ENTIRE SILL 1/4" MAX. r SHIM SPACE 1 1 1/4" MIN. T f EMBEDMENT CONCRETE/MASONRY A 1X 2" MIN. EDGE i WOOD BUCK BY OTHERS DISTANCE CONCRETE/MASONRY BY OTHERS VERTICAL SECTION 8 SILL - 1X WOOD ON CONCRETE/MASONRY INSTALLATION CLIP TWO (2) 3/16" ITW TAPCON INSTALLATION ANCHORS INSTALLATION CLIP ANCHOR REQUIREMENTS: WOOD SUBSTRATE: USE TWO #8 PAN HEAD WOOD SCREWS PER CLIP, IN ROW NUMBER ONE OF PREDRILLED HOLES SHOWN BELOW. METAL SUBSTRATE: USE TWO #8 HWH SMS ANCHORS PER CLIP, IN ROW NUMBER ONE OF PREDRILLED HOLES SHOWN BELOW. CONCRETE/MASONRY: USE TWO 316' ITW TAPCON ANCHORS, WITH ONE ANCHOR PLACED IN ROW NUMBER ONE AND ONE ANCHOR PLACED IN ROW NUMBER TWO OF PREDRILLED HOLES SHOWN BELOW. ANCHORS MUST BE PLACED DIAGONALLY ACROSS THE CLIP. iST 6.500" 1.500" 12 IP 0 O 0 0.625" 1.287' 1 2 3 INSTALLATION CLIP DETAIL 1 1/4" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE i 2" MIN. EDGE DISTANCE TWO (2) 3/16" ITW TAPCON INTERIOR INSTALLATION ANCHORS ONE (1) #8 SCREW, PER CLIP, FROM CLIP TO WINDOW FRAME 5 SEE GLAZING DETAIL CONCRETE/MASONRY —?-~ - SEE BY OTHERS PERIMETER SEALANT EXTERIOR BY OTHERS EXTERIOR FINISH BY OTHERS O.A. WINDOW WIDTH y HORIZONTAL SECTION 8 JAMB - CONCRETE/MASONRY INSTALLATION CLIP wls oows•oeows 100 FOURTH AVE NORTH BAYPORT, MN 55 3-t046 PH: (651) 264-5150 M (651) 264-5485 mMm w v # v 4oaH > 8 vi m o me T Z<m a j m3a oZ Z N n Z a a H d lec-o wo a3E u 0 m v) QN ` n of HvZ DWG #: AWD095 SHEET: 8 OF A SEE GLAZING SEE GLAZING INTERIOR EXTERIOR HORIZONTAL SECTION 9j ACTIVE/PASSIVE MEETING STILE INTERIOR EXTERIOR g HORIZONTAL SECTION C, ACTIVE/STATIONARY MEETING STILE GLAZING DETAIL EXTERIOR 3/4" O.A. IN5ULATED GLASS INTERIOR SILICONE BACK BEDDING 1/2" GLASS BITE NOTE: GLASS TYPE AND THICKNESS SHALL COMPLY WITH ASTM E1300-04 GLASS CHART REQUIREMENTS. 0.462" GLAZING DETAIL I 1.350" I 1.175" 1.294" ACTIVE SASH MEETING STILE PASSIVE/STATIONARY SASH MEETING SASH REINFORCEMENT REQUIREMENTS SIZE REINFORCING UNITHEIGHT> 54" REQUIRES STEEL REINFORCEMENT IN ACTIVE AND PASSIVE OR STATIONARY SASH MEETING STILES UNIT HEIGHT < 54" NOT REQUIRED wlwoows•eoo Rs IW FOURTH AVE NORTH BAYPORT. MN5 34M PH:(651 264-5M FX:(651)264-5485 a m CC m p W Z i ygnu. H Nm cn a w d a:1 H. O v I`.' Q w^w uco w m ZNm ZwN N Z U1 H Z J Kr y m lL t7 W p w m 2 d IwoQ 63 m 10m o 3t _ vZ n v h DWG #: AWD095 SHEET: 9 OF 9 FL # Application Type Code Version Application Status. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year(of.Standard) Equivalence of Product Standards Certified By Sections from the Code FL19564-RO New 2014 Approved Andersen Corporation 100 Fourth Avenue North Bayport, MN 55003 651) 264-5308 alan.barstad@AndersenCorp.com Alan Barstad alan.barstad@AndersenCorp.com Windows Double Hung viLD//V0 SANFORD Oq RTOf r 1 6 - 2 3 9 2 Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Hermes F. Norero, P.E. PE-73778 Window and Door Manufacturers Association 12/31/2019 Locke Bowden a Validation Checklist - Hardcopy Received FL19564 RO COI COI Andersen. SS 201 -08-31 odf Standard AAMA/WDMA/CSA 101/I.S.2/A440 AAMA/WDMA/CSA 101/I.S.2/A440 Year 2005 2008 file:///C:/Users/thaiia/Documents/Product%20Approvals/Renewal%20by%20Anderson%20Double%20Hung%20Product°/a20Approval.htm1 1/2 INSTALLATION NOTES: RENEWAL SERIES DOUBLE HUNG WINDOWS 1. INSTALLATION CLIPS: ONE (1) INSTALLATION ANCHOR CLIP IS REQUIRED AT EACH ANCHOR LOCATION SHOWN, EACH CLIP IS TO USE TWO (2) INSTALLATION ANCHORS. 2. THROUGH FRAME AND NAIL FIN: ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 3112 INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (I. E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE IMSTALLATION ANCHOR TO THE NEXT. 4. INSTALLATION CLIP: FOR INSTALLATION THROUGH 1X BUCK TO CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/MASONRY, USE TWO (2) 3116 INCH HWH ITW TAPCON PER INSTALLATION CLIP OF SUFFICIENT LENGTH TO ACHIEVE 1 114 INCH MINIMUM EMBEDMENT AND SHALL MAINTAIN MINIMUM 2" EDGE DISTANCE. S. INSTALLATION CLIP: FOR INSTALLATION INTO 2X BUCK USE TWO (2) 08 PAN HEAD WOOD SCREWS PER INSTALLATION CLIP OF SUFFICIENT LENGTH TQACHIEVE 1112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 6. INSTALLATION CLIP: FOR INSTALLATION THROUGH METAL STUD USE TWO (2) #8 HWH GRADE 5 SELF -DRILLING OR SELF -TAPPING SCREWS PER INSTALLATION CLIP OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 7. THROUGH FRAME: FOR INSTALLATION INTO 2X BUCK USE #10 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. 8. THROUGH FRAME: FOR INSTALLATION INTO METAL SUBSTRATES USE #10 HWH GRADE 5 SELF -DRILLING OR SELF -TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 9. THROUGH FRAME: FOR INSTALLATION THROUGH 1X BUCKTO CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/MASONRY, USE ONE (1) 3116 INCH ITW TAPCON OF SUFFICIENT LENGTH TO ACHIEVE 1 1/4 INCH MINIMUM EMBEDMENT AND SHALL MAINTAIN MINIMUM 2" EDGE DISTANCE. 10.NAIL FIN: FOR INSTALLATION INTO 2X BUCK USE #8 PAN HEAD WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1 112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 11.NAIL FIN: FOR INSTALLATION INTO METAL SUBSTRATES USE #8 HWH GRADE 5SELF-DRILLING OR SELF -TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL FRAME SUBSTRATE AND SHALL MAINTAIN MINIMUM 3/4" EDGE DISTANCE. 12.MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL. FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 13.INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 14.FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. IS.INSTALLATION ANCHORS SHALL BE INSTALLED IN. ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 16.INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD- MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000PSI. C. MASONRY- STRENGTH CONFORMANCE TO ASTM C-90 D. STEEL- MINIMUM YIELD STRENGTH OF 33 KSi. MINIMUM WALL THICKNESS OF 48 MILS(18 GAUGE). E. ALUMINUM -MINIMUM WALL THICKNESS OF%", 6063-TS ALLOY OR BETTER. FULL FRAME - NON -IMPACT GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE STH EDITION (2014) FLORIDA BUILDING CODE, EXCLUDING HVHZ. THE PRODUCT HAS BEEN EVALUATED TO THE FOLLOWING: AAMA/WDMA/CSA 101/I.S.2/A440-05/08 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X AND METAL STUD FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR. ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. S. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED TO PROTECT THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE, 6. WINDOW FRAME MATERIAL: FIBREX® AND PVC. 7. SEE SHEET 3 FOR GLAZING DETAILS. 8. DESIGNATIONS "X" AND "0" STAND FOR THE FOLLOWING: Xr OPERABLE PANEL O: FIXEDPANEL TABLE OF CONTENTS SHEET DESCRIPTION GENERAL 6 INSTALLATION NOTESZELEVATIONS6ANCHORLAYOUTS THROUGH FRAME INSTALLATION DETAILS 6 GLAZING DETAIL NAIL FIN INSTALLATION DETAILS 6 REINFORCEMENT REQ'5 CLIP INSTALLATION DETAILS DESIGN PRE55VRE RATING SIZE DESIGN PRESSURE 54" X 72" 20.0 / -20.0 PSF 45" X 77" 35.0 / -35.0 PSF 48" X 96" 20.0 / -20.0 PSF Digitally signed by Hermes F Norero, P.E. Reason: I am approving this document Date: 2015.12.18 20:00:09-05'00' w1UCows-000rts PK (651) 264-5150 FX:(651) 264-5465 Z m O V # v Z Hob j w O Q Q m m d LL OaW= LL ww a awc5 mwwjZmZ-tm a N 1 H H - CH C q H Q a j W m IliLUzZ ly 1 w m a pL .rF1 m x I To Z O H z V HaH v w NLU w m J N a N _ ::E U ZQ^! SV) bw& #: 1 of 5 FM UNIT MAX. WIDTH 54" MAX. D.L.O. 48" A A A 3 4 5 MAX. C D.L.O. 5 " X.. 31-1/4" D D D UNIT 1 3 4 5 MAX. 1 HEIGHT 72' MAX. D.L.O. 31-1/4" ELEVATION 54" x 72" MAX. O.C. SPACING SEE SCHEDULE CORNER DIST. — 1 I— SEE SCHEDULE i MAX. O.L. SPACING SEE SCHEDULE CORNER DIST. ] SEE SCHEDULE TYPICAL ANCHOR LAYOUT . UNIT MAX. WIDTH 48" MAX. D.L:O, 42" A A A 3 4 5 MAX. c D.L.O. 5 X, 43-1/4" UNIT D D D MAX. 3 4 5 HEIGHT 96" MAX. D.L.O. 43-1/4" ELEVATION 48" x 96" NOTE: ORIEL, COTTAGE, AND CUSTOM SASH SIZES ARE AVAILABLE UPON REQUEST SUCH THAT THEY DO NOT EXCEED MAX. SASH D.L.O. SIZES SHOWN HEREIN. RENEWAL SERIES DOUBLE HUNG - FULL FRAME ANCHORSPACING FROM MAX.O.C. MAX.O.C. MAX.O.C. INSTALLATION CORNERS HEAD SILL JAMBS METHOD IN) IN) IN) IN) NAILFIN 3.5 3.5 3.5 3.5 INSTALLATION 5 N/A N/A 16 CLIP THROUGH 5 N/A N/A 13.5 FRAME NOTES: 1) HEAD AND SILL ANCHORS ARE NOT REQUIRED FOR INSTALLATION CLIP OR THROUGH FRAME INSTALLATION METHODS 2) ANY TYPICAL SUBSTRATE SHOWN HEREIN MAY BE USED AT THE HEAD, JAMBS, OR SILL. EDGE DISTANCE AND EMBEDMENT SHALL BE AS SPECIFIED IN TYPICAL DETAILS. SEE INSTALLATION NOTES 4-11 FOR ANCHOR SPECIFICATIONS FOR EACH INSTALLATION METHOD. wlaoow•000as 100 FOURTH AVE NORTH BAYPORT, MN 5500340% PH: (651) 264-5150 FX: (651) 264$485 l m F m qq O V # a m z Dw VIm M Q Q V O W lL z t7 < V LL w a~c ' Ul m < Lu D z w z J Z < w doz J ui co a z J w w oc Q z Y n <1 Nz 0 DWG #: AW0096 SHEET: 2 OF 5 CAULK BETWEEN CONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS CONCRETE/MASONRY 2X WOOD BUCK BY OTHERS BY OTHERS I/4" MAX. EXTERIOR FINISH SPACE BY OTHERSBY . ..... .. ..... PERIMETER SEALANT BY OTHERS ° O.A. WINDOW HEIGHT EXTERIOR INTERIOR SEE GLAZING DETAIL q VERTICAL SECTION 3 HEAD - 2X WOOD BUCK THROUGH FRAME° • SEE GLAZING DETAIL EXTERIOR //"INTERIOR4J VERTICAL SECTION 3 CHECK RAIL SEE GLAZING DETAIL j ` 1 EXTERIOR INTERIOR O.A. WINDOW HEIGHT PERIMETER SEALANT 1/4" MAX. BY OTHERISrSHIMSPACE EXTERIOR FINISH BY OTHERS IX WOOD BUCK a f OPTIONAL) BY OTHERS PRECAST SILL CAULK BETWEEN OR CONCRETE BY OTHERS CONCRETE/MASONRY & 1X WOOD BUCK BY OTHERS g VERTICAL SECTION 3 SILL- 1X WOOD ON CONCRETE/MASONRY THROUGH FRAME 11/11" O.A. INSULATED GLA55 EXTERIOR INTERIOR SILICONE BACK BEDDING ASS BITE GLAZING DETAIL NOTE: GLASS TYPE AND THICKNESS SHALL COMPLY WITH ASTM E1300-04 GLASS CHART REQUIREMENTS. JAMB ANCHOR REQUIREMENTS: ONE ANCHOR 15 REQUIRED AT EACH JAMB ANCHOR LOCATION SPECIFIED ON ANCHOR LAYOUT. ONE ANCHOR I5 TO BE INSTALLED THROUGH EITHER OF THE TWO TRACKS AT EACH ANCHOR LOCATION SPECIFIED. 3 THREAD PENETRATION BEYOND METAL FRAME INTERIOR 1/4" MAX. r 3/4" MIN. EDGE SHIM SPACE f DISTANCE SEE GLAZING DETAIL wlxoowa•000xa 100 FOURTH AVE NORTH RAYPORT. MN 55W3-10% PH: (651) 264-5150 ft (651) 2645485 U m r:1 "' $ v#vp8 D w yj Jm m a u2 x cchl Jw 1y m W W Z)<< Z G mNwLLy' Co H+< J x e in'o Q N Lu H Q Z a 3 w Q m w L' Ti A FQ ONE (1) #10 GRADE 5 SELF -DRILLING ` INSTALLATION ANCHOR, SEE NOTES ABOVE : 1y METAL SUBSTRATE BY OTHERS d EXTERIOR (SEE INSTALLATION NOTE #14, SHEET 1) SHEATINGBY OTHERS7zEXTERIORFINISHBY OTHERS O.A. WINDOW PERIMETER SEALANT BY WIDTH OTHERS HORIZONTAL SECTION 3 IAMB -METAL FRAME SUBSTRATE THROUGH FRAME 1unu 4• LL 1[1 TF- 1[1 m m J V1 p N S f Z Q V DWG #: A W DD96 SHEET: 3 OF 5 SHEATHING & METAL 3 THEADSPENETRATION BEYOND METAL FRAME STUD BY OTHERS 3/4" MIN. EDGE CAULK BETWEEN DISTANCE #8 HWH GRADE 5 SELF -DRILLING FIN & METAL STRUCTURE INSTALLATION ANCHORS411 1/4" MAX. EXTERIOR FINISH r SHIM SPACE BY OTHERS y PERIMETER SEALANT 1 BY OTHERS o O.A. WINDOW HEIGHT SEE GLAZING DETAIL EXTERIOR INTERIOR q VERTICAL SECTION_ 4 HEAD - METAL FRAME SUBSTRATE NAIL FIN NAIL FIN/FLANGE IS REVERSIBLE, SEE ORIENTATION DIFFERENCE IN DETAIL A AND B SEE GLAZING DETAIL EXTERIOR 1 INTERIOR p VERTICAL SECTION 4 CHECK RAIL E:l 0 844" L062" TALL BOTTOM RAIL WOOD (LVL) REINFORCEMENT DETAIL 0.223" 0.793" RAIL AND STILE ALUMINUM REINFORCEMENT DETAIL SASH REINFORCEMENT REQUIREMENTS LOCATION REINFORCING REQUIRED SIZE REINFORCING UPPER SASH SASH HEIGHT, 37.8345" REQUIRES ALUMINUM REINFORCEMENT STILES INSERTED INTO STILE SASH WIDTH > 43.125" UPPER SASH OR REQUIRES ALUMINUM REINFORCEMENT RAILS SASH WIDTH z 36.125" AND INSERTED INTO RAIL SASH HEIGHT> 37.8345" LOWER SASH SASH HEIGHT> 38.9645" REQUIRES ALUMINUM REINFORCEMENT STILES INSERTED INTO STILE SASH WIDTH> 43.125" LOWER SASH OR REQUIRES ALUMINUM REINFORCEMENT RAILS SASH WIDTH >_ 36.125" AND INSERTED INTO RAIL SASH HEIGHT, 38.9645" SASH WIDTH, 43.125" LOWER SASH OR REQUIRES WOOD (LVL) REINFORCEMENT TALL BOTTOM RAIL SASH WIDTH? 36.125" AND INSERTED INTO RAIL SASH HEIGHT, 38.9645" 3/4" MIN. EDGE SEE GLAZING DETAIL 1/4" MAX. DISTANCE EXTERIOR INTERIOR INTERIOR SHIM SPACE WOOD STRUCTURE BY OTHERS1 #8 PAN HEAD WOOD SCREW INSTALLATION ANCHOR O.A. WINDOW 1/4" MAX. a HEIGHT - SHIM SPACE x i PERIMETER SEALANT 1 1/2" MIN. BY OTHERS 3/4" MIN. EDGE o EMBEDMENT DISTANCE SEE GLAZING DETAIL EXTERIOR FINISH BY OTHERS CAULK BETWEEN CAULK BETWEEN FIN EXTERIOR FIN A 2X WOOD BUCK 2X WOOD BUCK EXTERIOR FINISH BY OTHERS 2X WOOD BUCK BY OTHERS Y # 8 PAN HEAD WOOD SCREW O.A. WINDOW PERIMETER SEALANT BY CAULK BETWEEN INSTALLATION ANCHOR WIDTH OTHERS CONCRETE/MASONRY & 2X 1 1/2" MIN. WOOD BUCK BY OTHERS EMBEDMENT CONCRETE/MASONRY C HORI20NTAL SECTION BY OTHERS VERTICAL SECTION LI JAMB -WOOD BUCK 4 SILL - 2X WOOD BUCK NAIL FIN NAIL FIN wlnoows•000 xs l00 fouk'H AVE NORTH BAYPOPI, MN 55003-10% PH: (651) 264-5150 FX: (651) 26.5485 ui m ZLu n m S d V # S Za m r z H 8 t Jm 0 jtij mi d a v) ar8 l Q= Lu LuDzn zm< u)t=L m Hl'+m e L] r7 Z < G z LuLY H Q Z a w w ¢ < a m o a ww[/pm w N 0 mod, •'••. a pRO` S m k NZ SHEET: 4 OF 5 CAULK BETWEEN CONCRETE/MASONRY .,'_ CONCRETE/MA50NRYd2X BY OTHERS WOOD BUCK BY OTHERS 2X WOOD BUCK BY OTHERS EXTERIOR FINISH BY OTHERS PERIMETER SEALANT 1/4" MAX. BY OTHERS ° SHIM SPACE O.A. WINDOW HEIGHT 1/ EXTERIOR \ INTERIOR SEE GLAZING DETAIL A VERTICAL SECTION 5 HEAD - 2X WOOD BUCK INSTALLATION CLIP SEE GLAZING DETAIL EXTERIOR 1 INTERIOR p VERTICAL SECTION S CHECK RAIL EXTERIOR O.A. WINDOW HEIGHT PERIMETER SEALANT BY OTHERS EXTERIOR FINISH BY OTHERS 1X WOOD BUCK OPTIONAL)BY OTHERS CAULK BETWEEN CONCRETE/MASONRY 6 1X WOOD BUCK BY OTHERS rnA1ropTr-/A,3d°nKlDV AV OTWF:DG—f SEE GLAZING DETAIL INTERIOR g VERTICAL SECTION 5 SILL- 1X WOOD ON CONCRETE/MASONRY INSTALLATION CLIP 1/4" MAX. SHIM SPACE INSTALLATION CLIP ANCHOR REQUIREMENTS: WOOD SUBSTRATE: USE TWO #8 PAN HEAD WOOD SCREWS PER CLIP, IN ROW NUMBER ONE OF PREDRILLED HOLES SHOWN BELOW. METAL SUBSTRATE: USE TWO #8 HWH 5M5 ANCHORS PER CLIP, IN ROW NUMBER ONE OF PREDRILLED HOLES SHOWN BELOW. CONCRETE/MASONRY: USE TWO Y16" ITW TAPCON ANCHORS, WITH ONE ANCHOR PLAC D IN ROW NUMBER ONE AND ONE ANCHOR PLACED IN ROW NUMBER TWO OF PREDRILLED HOLES SHOWN BELOW. ANCHORS MUST BE PLACED DIAGONALLY ACROSS THE CLIP. DO NOT INSTALL ANCHORS THROUGH ROW NUMBER THREE. 6.500" 1.500" 12 IP 0jq 1.625.. 1 2 3 INSTALLATION CLIP DETAIL 1 1/4" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE 2" MIN. EDGE DISTANCE 4 INTERIOR TWO (2) 3/16" ITW TAPCON INSTALLATION ANCHORS e ONE (1) #8 SCREW, PER CLIP, FROM CLIP TO WINDOW FRAME y CONCRETE/MASONRY BY OTHERS PERIMETER SEALANT EXTERIOR BY OTHERS EXTERIOR FINISH SEE GLAZING DETAIL BY OTHERS O.A. WINDOW WIDTH HORIZONTAL SECTION IAMB - CONCRETE/MASONRY INSTALLATION CLIP w IxDOWf•o00 RI 100 FOURTH AVE NORTH BAYPORT, MN 55003-1096 P14: 051)264-5150 FX:(651) 26.5485 Z mm M j MV # pvpJ1<- H CJ m mm0lua0 ::E cc Imo= LL w < way O T w V) LPL JJ< m H H J J' a Z H a W H Q Z w Q w o g F Z w d ! M = hiTTI A 111#IpR yyy s F" co m V) J V) o 3 n =f NZ C) V DWG #: A WD096 SHEET: 5 OF 5 REQUIRED INSPECTION SEQUENCE BP# V6 _ 23 q Z Address: 2tkl t. • Z z- BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing— Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final Min Max Inspection Description Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final ME:CHANI.CAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Final PERMIT Min Max Inspection Description Gas Underground Gas Rough Gas Final REVISED: June 2014