Loading...
HomeMy WebLinkAbout262 Maybeck Ct (2)CITY OF SANFORD RECEIVED BUILDIN f F fIRE PREVENTION P T APPLICATION7BY: CT tion No:Applica 2,400.00 Documented Construction Value: $ Job Address: 262 Maybeck Court Historic District: Yes No [IQ Parcel ID: 26-19-30-5SY-0000-1200 Residential V Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of York: screen room with 3" Elite panel roof on existing slab Plan Review Contact Person: Don Geissler Phone: 407 461-9929 Fax: 407 365-3194 Name Latoya Hinson Street: 262 Maybeck Court . Title: President Email: sunstatesiding@aol.com Property Owner Information City, State Zip: Sanford, FL 32771 Phone: 407 324-6873 Resident of property? : yes Contractor Information Najme Donald G. Geissler, Jr Sun State Si Street: 510 Lake Lenelie Drive Inc Phone: 407 830-7778 Fax: 407 365-3194 City, State Zip: Chuluota, FL 32766 State License No.: SCC048423 Arch itectlEngineer Information Name: Michael Thompson Aluminum Screen Design Street: 4401 Vineland Road, A6 Phone: 407 734-1470 Fax: 888 923-8181 City, St, Zip: Orlando, FL 32811 E-mail: aluminumscreendesign@yahoo.corn Bonding Company: MortgageLe der: Address: Address: I KV WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a.separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51 Edition (2014) Florida Building Code 0 Revised: June 30, 201 S Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required fi-om other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation 'fable in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER' AFFI DAVIT: I certify that all of the foregoing information is accurate and that all work will be done 'n ompliance wi h all applicable laws regulating construction and zoning. 2Z 14o tq— ignat re:. ,Oi nerlAgen Date' Signature of Contractor/Agent Date i j4St Print 91 ' __ .gent's Nam I Print Contractor/Agent's Name 4Si nature, ",, otaryvSiate of Flo lila _ Signaturcn£Notary-State o£Florida i f' 71'G'o' :-rJT Gfm was- Date Owner/Agent is Personally Known to Me or Contractor/Agent is Personally Known to Me or Produced ID i "P pe of ID 0 j Produced ID Type of ID W KAREN N080A Notary Public - State of Florida My Comm. Expires Oec 29, zo17ELOW IS FOR OFFICE USE ONLY Commission # FF 079918 ermits equired: ui ding Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire. Alarm Permit: Yes No APPROVALS: ZONING:fl o UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: IF—' 1044,1 COMMENTS: t/k VI OWl O0 e WJ1n Aftc &OW ` J Revised: June A 2015 Permit Application W SUN STATE SIDING, INC. 510 LAKE LENELLE DRIVE CHULUOTA, FL 32766 407 830-7778 phone 407 365-3194 fax Submitted to: Latoya Hinson 262 Maybeck Court Sanford, FL 32771 407 324-6873 teamhinsonfamily(cb-gmaii.com PROPOSAL State License SCC048423 PROPOSAL# 1 DATE 09/21/2016 Job Location: SAME Riverview Lot 120 We propose to furnish all the materials and perform all the labor necessary for the completion of: Furnish and.install screen room on existing slab with 3" Elite panel roof $ 2,400.00 with 12" overhang, extruded drip edge fascia, 14' of 6" gutter and (1) 3 x 4 downspout, 1) 3' 0" x 6' 8" screen door, 18 x 14 charcoal screen, finish caulk. Chair rail height is 36" Site specific, engineer stamped plans & City of Sanford permit $ 300.00 All material is guaranteed to be as specified and the above work to be performed in accordance with the drawings and specifications submitted for the above work and completed in a substantial workmanlike manner for the sum of: SEE ABOVE With payments to be made as follows: FULL PAYMENT UPON COMPLETION (we accept CASH or CHECK only) Any alteration or deviation from the above specifications involving extra cost will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry fire, tornado, and other necessary insurance upon the above work. Workman's Compensation and Public Liability insurance on above work to betaken out by Sun State Siding, Inc. THERE WILL BE A $50.00 BOOKKEEPING CHARGE IF THE INVOICE IS NOT PAID IN 30 DAYS. Submitted by DONALD G. GEISSLER, JR., PRESIDENT This proposal may be withdrawn by us if not accepted within 30 days. ACCEPTANCE OF PROPOSAL The above prices spec' 'cati - ns and conditions ar satisfactory and are hereby accepted. You are authorized to perform the work specified. Paym nt be ade w ouili o e. Signatur Date_ T-- Printed am 1, 1 U rN — RECORD COPY r r ALUMINUM SCREEN DEIGN A i aa 7ir1 rti C c: Slr ud;ii r Cngin ';o ir7< P'Ian Types: Screen Room Pool Screen/Cage (Removable Screen - Remove screen when wind speed exceeds 75 MPH) Pool Screen/Cage (Non -Removable Screen — Designed to withstand actual Wind Speed) Car Port F-] Patio Cover F-1 Other: REVIEWED FOR CODE COMPLIANCE PLANS MINER DATE Reference: Hinson RV120 New Revisions Date: 9/22/2016 Project Address: 262 Maybeck Court City: Sanford, FL Contractor Name: Sun State Siding, Inc Address: 510 Lake Lenelle Drive City: Chuluota, FL Zip Code: 32766 Donald G. Geissler, Jr Phone/Fax:407 830-7778 ofc/407 461-9926 cell/407 Email: sunstatesiding@aol.com SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT 365-3194 faWE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Choose One. Mail Pick UpF] Fed Ex*FI 2 No of Copies For FedEx option got to www.aluminumscreendesign.comcom and provide FedEx account #) Payment: Check Credit Card * For Credit Card option go to www.aluminumscreendesicin.com to pay by credit card) Engineering prepared by: OALUMINUM SCREEN DESIGN Elm Ultimate Wind Speed (mph): 130 Exposed Category: C Risk Category: Insulated Pan Roof Fascia Wall: Block Conventional Uprights _ 2 x 3 Top Plate 2 x 2 Kick Plate Pa'ol' Screen/Cage: Dome Gable Mansard Gutter Wall: Block Conventional Beams x Uprights x Purlin x Insulated Pan Fascia Wall: Block Conventional Beams x Post x F Existing New: 4" Slab Pier Ribbon Footer x Pavers[] Other: Note: In the event that there is a conflict with the design plans and general notes and design standard, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and the general notes and design standard. i.4 General Notes & Design Standards Screen Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. lrr the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2014 (5" Edition) Aluminum Design Manual 2010 ASCE 7-10 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -130 MPH (HBC !able 2002.4) (35 psf) Risk Category: -See attach site specific plan sheet (FBC %able /604.5) Exposure Category: -See attach site specific plan sheet (f'BC 1609.4.3) Additional Load requirements: Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any I foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com mm Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice f6i"aluminum design. All aluminum shall be 6005=T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B18.6.4 specification. Self—tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro -galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 tirnes the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Chair Rails. Purlins & Wind Brace: Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction. Wind Speed =130 M1111 2 x 2 Chair Rail = 6'-0" 2 x 2 Purlins = 6'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 9'-0" 2 x 3 Chair Rail = 8'-0" 2 x 3 Purlins = 8'-0" 2 x 3 Wind Brace = 8'-0" 2 x 4 Wind Brace = 9'-0" Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be 1/4" Reinforcing Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A 185 Welded Wire Fabric shall be ASTM At 85 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Hole Alienment: Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips and foreign matter between contacting surfaces shall be removed before assembly. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com Beams & Uprights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 130 MPH PRIMARY BEAMS & COLUMNS -SCREEN & PATIO ROOM ENCLOSURES ROOF PANELS Beam -Size Max Beam Span & Max Column Spacing Column -Size Max Column -Height Pan Roof Span Insulated Roof Span 2 X 3 6'-0" 2 X 3 8'-0" 3" Spans 13'- 6" 3" Spans 15'-0" 6" Spans 20'-0" 2 X 4 8'-6" 2 X 4 8'4" 2 x 5 10'-0"1 2 x 5 9'-0" 2 X 6 12'-0." 2 X 6 10'-0" Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach cletail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater than 30'. Purlin• Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall not exceed 7'-2". Intermediate/Header Beam: Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds 15 feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of 1'-0" along the side, 3'-0" along the front and 1/2" along the front interface between the super gutter and the attached pool cage knee riser wall. Edge Distance: Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com oof FLAt4 y><¢ RTE VI / LOT SUN STATE SIDING, INC.. W ,0 LAKE LENELLE DRIVE ULUOTA, FL 32,766 DONALD G.-GE1SSLER, JR. SCC048423 407 830-7778 PHONE1407 365-3594 nE1.1Tir Pt3NGt. Ir'b FRa T, wAu, SIVE v4AL S Mort. 2x2 ZIc3 ZK3 c.RnoJ Z x x F?AY VARY. D00Po.. r 2-42, (AZ SPgN . 2K 36 ` 1xz 36" 30' --Ill 6 ,' Nq fl/S ip In the event of a conflict in member sizes shown on the plans and the general notes, the contractor must utilize the more stringent member size requirements. ALUMINUM SCREEN EXTRUDED FASCLA IS ATTACHED TODESIGN.)" 3" C CHANNEL IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS INSULATED ROOF WITH #10 1" 6" 6" FROM ENDS 24" O.C. & TO 3" INSULATED ROOF WITH 6) 410 1" PER SIDE FROM ENDS 24" O.C. I nil ROLL FORM GUTTER IS ATTACHED TO 3" INSULATED ROOF WITH 910 1" 6" FROM ENDS 24" O.C. ROOF IS ATTACHED TO FRONT WALL WITH (4) #10 4" PER PANEL 2X2 POST .046 OR GREATER 2 HINGE DOO 2X3 FRONT WALL TOP PLATE HINGE LOCATIONS SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL EACH DOOR IS SCREWED NTO UPRIGHTS WITH 410 1" 6" FROM ENDS 24" O.C. KICK PLATE IS ATTACHED TO STRUCTURE WITH 4! 10 1" 6" FROM ENDS 18" O.C. UPRIGHTS ARE ATTACHED WITH: BLEND SCREWED WITH (3) 4'10 3", CAPRI CLIPPED WITH (4) 910 1" PER CLIP BLIND CLIPPED WITH (4) 410 1" PER CLIP 1X2 IS ATTACHED TO FRONT WALL WITH 910 2" 6" FROM ENDS 24" O.C. CHAIR RAIL IS ATTACHED TO UPRIGHTS WITH EITHER: BLIND SCREWED WITH (3) 410 3 CAPRI CLIPPED WITH (4) 410 1" PER CLIP BLIND CLIPPED WITH (4) 410 1" PER CLIP UPRIGHTS ARE ATTACHED WITH: BLIND SCREWED WITH (3) 410 2", CAPRI CLIPPED WITH (4) 410 1" PER CLIP BLIND CLIPPED WITH (4) # 10 1 " PER CLIP INSULATED ROOF IS ATTACHED TO LUMINUIVI STRUCTURE WITH #10 4" FROM ENDS 24" O.C. 2X2 SIDE WALL TOP PLATE IX2 IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS 6" FROM ENDS 24" O.C. 2X3 SIDE WALL UPRIGHTS f vxoj 9wl:l IX2 IS ATTACHED TO CONCRETE WITH 2-1/4" X 1/4" TAPCONS 5" X 1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. ALUMINUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON ALLIw][INUMSCREENDESIGN METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 4401 VINELAND ROAD ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" EMBEDMENT DEPTH TJIiE A6@YAHOO.COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) PHONE: 407-747-1470 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND ORLANDO, FL 3.2811 SPEEDS OF 130 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 101.4 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. U E #` 475 09IFAX: 407-734-1790 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION JCONTRACTORSHALLNOTIFYTHEENGINEERIMMEDIATELYSHOULDSITECONDITIONSDIFFERFROMCONSTRUCTIONPLANS309-0 c e4*80ciatesinc. Land Surveyors 769 Douglas Avenue, Altamonte Springs, Florida. 32714 (407)788-8808 Member of the Florida Surveying and Mapping Society and American Congress on Surveying and Mapping Lot 117 Map of Survey vc& on I b Tract C" ae & Retention ter+aen rrimmn vd,zmn r nror, Riverwel —7 --Unit Fe fished Floor Lot 118 Lot 119 1 Lot 120 Lot 121 ninon I r»-- I L -.V— 25.1 Lot 122 1 Lot 123 N00'1000"W 7 73.49` CIL Maybeck Court 34' RIW) Tract 'B"Access LEGAL DESCRIPTION Lot 119, Riverview Townhomes Phase 11, according to the plat Nereofas recorded in plat book 75 at pages) 51- 58 of me pubrlc recards orseminare county, Florida. Lot 125 Bow on on PA— PA 8 P 1l0 - 2'18` APPROVED PLANS o b Etv-ISA o 1 s to0-4 yl o k S1c re.t r0'C>V`V-'% ov-L tJ(iS iti SIa b Address: 260 Maybeck Coud'J s - „ sk4 kV- v - FLOOD HAZARD DATA: The parcel shown hereon lies within hood zone `X - according to the Rood insurance Rate Map community panel number SETBACKS: 120294-006OF datad 9aW001. Front:21.5' Side :7.17' Rear: 4.T Rood Zone detemlinalion was performed by graphic piecing from Flood 8EARING BASE. -The bearings shown hereon are based upon the Insurance Rate Maps provided by FEMA. No held surveying was performed by eastern plat boundary as being N00'10VO W. Ibis rum 10 determine this zone. The exact zone location can only be determined byan elevation study. We assume no respon"Ity laractual flooding Venice/datum Is based on engineering plans as provided by the client, conditions prepared by Evans Engineering. Ina, Job A' 12001. General Notes_ 1. This Is a BOUNDARY Survey,oedonred in the Feld an Legortd Z No aerial, suddce orsubsudaee utility installations, underground Improvements or a Temporary aerxhmark ap_e. an—dr aeek subsudateraerial encroachments, tl any, were located. assumeddefum) Pa Plat Book 3. Budding lies shown are to the exterior untinishedloundat)on It or formboard. aow eau of yderaik ntedne PC Poem of curvature 4. Elevattons shown hereon, it any, are assumed and were obtained from approved as Cen (DeRa)Angla PCC. Poimot Compormd Curvalum Paeamm ContrdPant Construction plans provided by the Client unless otherwise noted, and are shown CALC Calculated FG. FG. only to depict the proposed of actual difference in elevation relative to me assumed ce Chord Bearing P.RAP M. Permanent RBkrerxe MerrumeAt temporary Benchmark shown hereon. S. The parcel shown hereon is subject to as easements, reservations, restriction; and COGM. CholdConcrete Momrm n? PAP.0.a. Property Ura Pofm d Beymniv Rights -of -Way of record whether depicted or not on this document No search of me EL. nrFLEVEL Hevener /Proposed) Elevation (Measured) P.D.G P.1 -I &Cammenosmmt Pond dhden Public Retards has been mane 0Y this office. 6. The legal description shown h3moin is as furnished by client. FDFIXraft FJaV. FoundFWseedFloorflevetion ALPRCPT. Point of Reverse cerohaa point or Tarrgenry 7. parted and measured d/stances and directions are the same unless othanv)so noted. I.P. hon Prpe R Radius 6. Copies of this Survey may be made for the original transaction only. I.R. bon Rod RAD RtdSal Line a Denotes H-Jmn rod ivdh plastic cap marked LB4937, or W iron rod with L Am Length RES. Reaidomm ied plastic cap merited -MM ass Comer unless otherwise noted. La Mea ucansed evs1— Land surmyor FJW TBR Righly yiyy Temporary Benchmark O Denotes P.c.P. (Permanent control point) Menumd TYP. at Denotes Permanent Reference Monument N/D(NLO) NaOendDisk rte AinTypicat Feece slmbot (see d-.iM) 0 2010 Hen 8 Associates Ina Aadrights reserved9 N.P.Nal R.did dr—+X- Fexe rrmbellsw ee":np) Ne Dam.L PramienL-cAt P.S.M. Regis.ereo Nee 2 Associates Inc. Stals of Florida t9 lleuWlTitleAgency, L td., L.C. Stewart TitleGaranty Company At. 9102 Hen M':h==Q d tdapparNo. 6o90 Drawn Dy: CM Checked by: OP Prepared for. Mn Nomee Jab NDmber. 07-405-02 Scalp: 1".40' by Final Survey: 09-15.10 D;Zy CO of Sanford Building a ' '1'. • Prevention Project Location Product Approval Specification Form As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Florida Approval # Description include decimal 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shin les Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. RoofFow, Panels t - E t G Cort 30 55 0 — R;4 Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014 POWAI-D G . tsit 55LICIR Q --X ENGINEERING EXPRESS® k -W. -I " is ® PRODUCT EVALUATION REPORT ENGINEERING EXPRESS EXPERT January 30, 2015 Application Number: FL# 5500.1-R4 Project Number: 14-1438 Product Manufacturer: Elite Aluminum Corporation Manufacturer Address: 4650 Lyons Technology Parkway Coconut Creek, FL 33073 Product Name & Description: EPS Foam Core Composite Roof Panels Aluminum / Aluminum Skin Scope of Evaluation: This Product Evaluation Report is being issued in accordance with the requirements of the Florida Department of Business and Professional Regulation (Florida Building Commission) Rule Chapter 61 G20- 3.005, F.A.C., for statewide acceptance per Method 2(b). The product noted above has been tested and/or evaluated as summarized herein to show compliance with the Florida Building Code Fifth Edition 2014) and is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or revisions. Substantiating Data: PRODUCT EVALUATION DOCUMENTS FLB drawing #14-1438 titled "EPS Foam Core Roof Panels", sheets 1-1, prepared by Frank L. Bennardo, P.E., Inc., signed & sealed by Frank L. Bennardo, P.E. is an integral part of this Evaluation Report. TEST REPORTS Uniform static structural performance has been tested in accordance with Section 1714.3 of the 2004 Florida Building Code per test standard ASTM E72-05 as evidenced in the following test reports by Hurricane Engineering & Testing, Inc. (HETI): 3" Panels with 0.024" Aluminum Facing: HETI -05-1988, HETI -05-1992, HETI -06-2066, HETI -06-2067, HETI -06-2068 3" Panels with 0.032" Aluminum Facing: HETI -05-1993, HETI -05-1989 4" Panels with 0.024" Aluminum Facing: HETI -05-1994, HETI -05-1987, HETI -06-2069, HETI 4" Panels with 0.032" Aluminum Facing: HETI -05-1985, HETI -05-1995 6" Panels with 0.024" Aluminum Facing: HETI -05-1996, HETI -05-1991, HETI -06-2072, HETI 06-2073, HETI -06-2074 6" Panels with 0.032" Aluminum Facing: HETI -05-1997, HETI -05-1990 Metal tensile capacity has been determined in accordance with ASTM E8-01 test standard per test report(s) #HETI-05-T337 (0.024" aluminum facing) & #HETI-05-T338 0.032" aluminum facing) by Hurricane Engineering & Testing, Inc. (HETI). 160 SW 12TH AVENUE #106 DEERFIELD BEACH, FL 33442 PHONE: 954-354-0660 FAX: 954-354-0443 WWW.ENGEXP.COM ENGINEERING EXPRESS' Elite aluminum Corp. — EPS Foam Core Composite Roof Panels STRUCTURAL ENGINEERING CALCULATIONS 30, 2015 Structural engineering calculations have been prepared which evaluate the product based on comparative and/or rational analysis to qualify the following design criteria: 1. Maximum Allowable Size/Pressure Combinations No 33% increase in allowable stress has been used in the design of each product. Impact Resistance: Large & Small Missile Impact Resistance has NOT been demonstrated as evidenced in previously listed test reports, and is accounted for in the engineering design of this product. Wind Load Resistance Each product has been designed to resist combinations of wind loads, live loads, and dead loads as indicated in the span schedule(s) on its respective Product Evaluation Document (i.e. engineering drawing). Installation Each product listed above shall be installed in strict compliance with its respective Product Evaluation Document (i.e. engineering drawing), along with all components noted therein. Each product component shall be of the material specified in that product's respective Product Evaluation Document (i.e. engineering drawing). Limitations & Conditions of Use: Use of each product shall be in strict accordance with its respective Product Evaluation Document (i.e. engineering drawing) as noted herein for outdoor patio construction only. All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in each product's respective anchor schedule. Host structure conditions which are not accounted for in each product's respective anchor schedule shall be designed for on a site-specific basis by a registered professional engineer. All components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times. Each product has been designed for use outside the High Velocity Hurricane Zone (HVHZ). Product shall be fabricated using expanded polystyrene insulating foam manufactured by Dyplast Products, Inc. as listed in Miami -Dade Notice of Acceptance # 11-0926.07 (or the current version of this NOA). 160 SW 12T" AVENUE #106 DEERFIELD BEACH, FL 33442 PHONE: 954-354-0660 FAX: 954-354-0443 WWW.ENGEXP.COM rida Eiftlding Code Online https:l/tloriaaouuum6---s,r•,r Comments Archived Pubrications FBC Staff SCIS Site Map Product Manufacturer Elite Aluminum Corporation 4650 Lyons Technology Parkway Address/Phone/Email Coconut Creek, FL 33073 954)949-3200 dk@dokimengineering.net Frank Bennardo Authorized Signature frank@engexp.com Bruce Peacock Technical Representative Parkway Address/Phone/Email 4650 Lyons Technology y Coconut Creek, FL 33073 954)949-3200 bpeacock@elitealuminum.com Quality Assurance Representative Address/Phone/Email Roofing Category Metal Roofing Subcategory Compliance Method Evaluation Report from a Florida Registered Architect or Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Frank L. Bennardo, P.E. the Evaluation Report PE -0046549 Florida License Quality Auditing Institute Ltd. Quality Assurance Entity Quality Assurance Contract Expiration Date 12/31/2018 Validated By Jorge A. Pomerantz, P.E. Validation Checklist - Hardcopy Received Certificate of Independence 1 of 2 FL5500 R4 COI Indep.pdf 4/18/2016 10:3' BCIS Home Log in User Registration Hot Topics Submit Surcharge Stats & Facts Busines) sproductApproval Professional r>r2 USER: Public Userfit' Aoofcation Search > Application List > Apprcation DetailProductAoorovalMenu > Product or FL5500-R4 FL # Revision Application Type 2014 Code Version Approved Application Status Comments Archived Pubrications FBC Staff SCIS Site Map Product Manufacturer Elite Aluminum Corporation 4650 Lyons Technology Parkway Address/Phone/Email Coconut Creek, FL 33073 954)949-3200 dk@dokimengineering.net Frank Bennardo Authorized Signature frank@engexp.com Bruce Peacock Technical Representative Parkway Address/Phone/Email 4650 Lyons Technology y Coconut Creek, FL 33073 954)949-3200 bpeacock@elitealuminum.com Quality Assurance Representative Address/Phone/Email Roofing Category Metal Roofing Subcategory Compliance Method Evaluation Report from a Florida Registered Architect or Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Frank L. Bennardo, P.E. the Evaluation Report PE -0046549 Florida License Quality Auditing Institute Ltd. Quality Assurance Entity Quality Assurance Contract Expiration Date 12/31/2018 Validated By Jorge A. Pomerantz, P.E. Validation Checklist - Hardcopy Received Certificate of Independence 1 of 2 FL5500 R4 COI Indep.pdf 4/18/2016 10:3' arida auildiing Code Online Referenced StandardStandard and Year (of Standard) https://uonaaowturtrr,-v'&F., Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL5500 R4 Eouiv Eg iv.pdf Sections from the Code 104.11.2 1709.3 Product Approval Method Method 2 Option B Date Submitted 02/26/2015 Date Validated 03/08/2015 Date Pending FBC Approval 03/09/201504/15/2015 Date Approved Summary_of Products Descriptionton FL # Model, Number or Name _ ._- --- -- -- - Aluminum /Aluminum Roof Panels EPS Foam Core Composite Patio Roo Panels 5500.1 Installation Instructions Limits of Use FL5500 R4 II Dwq.pdf Approved for use in HVHZ: No Verified By: Frank L. Bennardo, P.E. PE00465 Approved for use outside HVHZ: Yes Created by Independent Third Party: Yes Impact Resistant: No Evaluation Reports Design Pressure: N/A 5500 R4 AE Eval.pdf Other: For outdoor patio construction only. For use outside R the HVHZ. See installation drawing for allowable span/load 0— 00 R4 AE NOA Reports oFL55i.pdf combinations. FL5500 R4 AE Test Reports 2.pdf Created by Independent Third Party: Yes Back Next; contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privao+ytatement :: Accessibikv statement cords. If you do not want your e-mail address released in response to a public -records requ• Under Florida law, email addresses are public reby traditional mal. If you have any questions, please contact 850.487.1: electronic mail to this entity. Instead, contact the office by phone or Section they have one. The em Florida s provided may be used for officiall communication withcensees thehe lice Sunder C eep However email ache public. are pubdeterDepartmentdeterminerecord. If y supply a personal address, please provide the Department with an addressss which can click maLerede available to the pubic. lb determine iF you 4S5 F.S plea Product Approval Accepts: A 0fee, ::re: . 2 of 2 4/1812016 10:3" EPS FOAM CORE ROOF PANELS ALUMINUM / ALUMINUM SKIN MA VIM Inn Al I nwARI_F CLEAR SPAN TABLES: CLEAR SPAN TABLE USE INSTRUCTIONS: I. DETERI.IINE TYPE OF ENCLOSURE TO BE COVERED (OPEN, SCREENED WALLS, OR FULLY ENCLOSED). 2. DETERMINE THE SITE SPECIFIC REQUIRED DESIGN WIND PRESSURE PROVIDED BY SEPARATE ENGINEERING, BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, IN ACCORDANCE WITH THE FLORIDA BUILDING CODE FIFTH EDITION (2014). 3, FIND ALLOWABLE COMPOSITE PA14EL CLEAR SPAN IN TABLES FOR APPROPRIATE PANEL DEPTH, FACING THICKNESS, AND EPS CORE DENSITY_ -- SEAL JOINT CONTINUOUS C.'UuLuKING u ° u voo u v CRO55 SECTION AT TYPTCAtE*AiJEC7R'T_ERCDCK EPS ROOF PANEL SPAN DETAIL: 0.024" OR 0.032" ALUM 4' MAX WIDTH PER INTERLOCKING PANEL r TOP E. BOTTOM FACINGS (1/4" PER FOOTMIN SLOPE) CLEAR SPAN (L) INSIDE TO INSIDE -- REFER TO ADDITIONAL ENGINEERING SHEETS FOR LOADS, ROOF CONNECTIONS, & SUPPORTING STRUCTURE DETAILS (BY OTHERS). THIS SHEET CERTIFIES ALLOWABLE RDOF SPANS ONLY. nn —AAI TA nI GC - T Pan01a 4" Panels 0"Panels - - Llvu Lwd Dellocllon 0.024" 0.032' 0.024' i 0.032• 0.024" 0.032' Alum Skln:AWm SklnWorUP00UnitAlumSkinAlumSklnAlumSkln'.Alum Skin 0.024" 0.032' 1 -Ib EPS i•Ib EPS 1.Ib EPS 1 •N EPS 1 -Ib EPS i /•Ib EPS 1 psi —!L 1 120 147.0•, 10,•3' 19'•0" 19"c" 23,•2" 23'-a' 12 PSI i Lf 120 13'-2" 15'•3' iT•12' 1T-11" 21'-T 22'•5" 14 PSI ; L 1120 12'•7" 14'-6" 1T•1" 1T 9' 20'-B" 21.7" 10 pal L 1120 11'-12" 13'-10" 10'-1' 16'•3' 1a-10" 20'•4" 18 Ps( L1120 11'-6" 13'•4" IS -0' 15'-B" t0'-0 IT -7' 20 Ps1 21120 11'•2 12'-1a' 15-2 15'•1" 10'•1' 10.11" 24 PSI ' L / 120 10,-G" 12'-1" 14'-3- 141•3. 1/'•7' 17•,5" 28 psl i L 1 120 9'-11" 11'•6" 17'-5" 13••6" 10'-.'i' 16••2, 32 Psi i L 1 120 9'4" _ 11'•0" 12'•6" 1 1T4" 1 15.5" 15:1" CLEAR SPAN TABLE USE INSTRUCTIONS: I. DETERI.IINE TYPE OF ENCLOSURE TO BE COVERED (OPEN, SCREENED WALLS, OR FULLY ENCLOSED). 2. DETERMINE THE SITE SPECIFIC REQUIRED DESIGN WIND PRESSURE PROVIDED BY SEPARATE ENGINEERING, BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, IN ACCORDANCE WITH THE FLORIDA BUILDING CODE FIFTH EDITION (2014). 3, FIND ALLOWABLE COMPOSITE PA14EL CLEAR SPAN IN TABLES FOR APPROPRIATE PANEL DEPTH, FACING THICKNESS, AND EPS CORE DENSITY_ -- SEAL JOINT CONTINUOUS C.'UuLuKING u ° u voo u v CRO55 SECTION AT TYPTCAtE*AiJEC7R'T_ERCDCK EPS ROOF PANEL SPAN DETAIL: 0.024" OR 0.032" ALUM 4' MAX WIDTH PER INTERLOCKING PANEL r TOP E. BOTTOM FACINGS (1/4" PER FOOTMIN SLOPE) CLEAR SPAN (L) INSIDE TO INSIDE -- REFER TO ADDITIONAL ENGINEERING SHEETS FOR LOADS, ROOF CONNECTIONS, & SUPPORTING STRUCTURE DETAILS (BY OTHERS). THIS SHEET CERTIFIES ALLOWABLE RDOF SPANS ONLY. nn —AAI TA nI GC - DEFLECTION NOTES: 1, USE L/120 FOR ALL MEMBERS SUPPORTING ROOFS OVER AN OPEN OR SCREEN -WALLED LOOM, 2. USE L/180 FOR ALL MEMBERS SUPPORTING ROOFS WITH A NON -PLASTERED CEILING OVER AN ENCLOSED ROOM. 3 ENCLOSED ROOM, PER IFLLOR DA BUILDING CODE ERS SUPPORTING FFIFTH EDITION ( 201S WITH A DCEILING N USE L/240 FOR ALL )TA13 E 1604 3n MAXIMUM ALLOWABLE DESIGN PRESSURES: AS NOTED IN CLEAR SPAN TABLES DESIGN NOTES: THIS SYS EM SHALLTBE DETvE ERMINED BY OTHERSLON A )OB --SPE IF CTED FOR USE WITH BASIS IN ACCORDANCE WITH THE GOVERNItJG CODE. SITE•SPECTH APRESSUREREQUIREMENTSASDETERMINEDINACC00.DANCE WITN ASCE 7.10 AND CHAPTER 1609 Of THE FLORIDA BUILDING CODE FIFTH EDITION 2014) SHALL BE LESS TIIAIJ OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. GENERAL NOTES: I. THIS SPECIFICATION HAS BEEN DESIGNED AND SHALL BE 3, THE ARC! SUPERSTRUCTtRESPONSIBLE THIS DESIGN V CONTRACTOR, 4. SEPARATi REQl""ED IN C CONTAINED HE TABLES LISTF.0 ENGINEER FOR 5. THE SYSI INFORMATION FROM THE CON REGISTERED A USE IN CONIUI G. TILE CON LOADS ON RO( LOADS WHICH ADDITIONAL R LICENSED ENC 7. EPS COR CHAPTER 7 SECTION 720, 115H. AND CHAPTER 215 WHICH Y. INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THIS SYSTEM. ITER/ENGINEER OF RECORD FOR THE PROJECT tE WITH 1'1Hicii THISDESIGN IS USED SHALL BE RCHSHALL BEINTEGRITY THE COORDINATED BY THE PERMITTING TO SITE-SPECIFIC' SEALED ENGINEERING SHALL BE IIN. UNE RI NTERPOILATION 0 DTI E ALLOWABLE SPANS HEREIN SHALI NOT BE PERI4ITTOL, CONTACT THIS n 1—fATF aPAN CALCULATIONS AS 14AY BE REQUIRED. OF 1 BY OTHER CONSIDERATIONS: BEYOND THAT WHICH IS CALLED FOR E 111110 M DEVIATIONS OF Th1I5 PLAN. FIFRONT OVERHANGI.1AY DEUPTO 3'•0" WITH VALUES LISTC•D I7E(tE1N. 14AXIMUM 10. EXCEPTAS EXPRESSLY PROVIbE[ SUPPORTED SDE OVERHANG IS 2546 OF LAST PANEL WIDTH (I.O. 12" MA% FOIt 48" CERTIFIG\TIONSORAFFIRMATIONS AI IJEL WIDTH). El. ALT[RTIONS, ADDITIONS, HIGI OF PITCH Sh1ALL OE AS PER BUILDING_CODE REQUIREMENTS __,____! THIS DOCUMENT ARE NOT PERMITTED CERTIFICATION. Pnn01s PANEL-/ 4" Panels 6 Panels DEPTH Liva LoaJ OPOacil' 36" MAX O/H AT FRONT & 25% 0.072' 0.024" 0.032' 0.024" 0.032' dfor UPf(1 i LNnBin AWm Skin Num Skin Alcon Skin Num SNin Num SklnStdhEP14hEPS1•Ib GPS 1-IbEPS 1-IbEPSFD12'•5,• 14••7•' 14•6•IB- 2L_L124__11__'3 15 psf CLI1B 13 '_....._. IT.Z.... 10_'_....._ 10'B' 17 I L/ 18" 11'-10' 1T12" 13'•H" 16'•11" LI24 psl i0'-9•, 1T B" 12'•B' 10•5 1'•ta' IL/ 18 11'•3'._ 13'-3".. 19 2' 1G I" 16'•B" 20 PS' I LI240 0'•10" 1a-3" 12.0" 1112" 147" 14'42" Ll100 9'•2' ta•7" 12'•5' 173' f I" 19.6' 2.1 psf L1240 W.4" 9'•7" 11'•4" :...11'•3• 13,9_-_-•,,. 14A"..-. L 1100 U'•t1" 10- 11•10" 11'•70" 14'14" 14' 9" 26 psl L 121 7'-11" B'-_ 1a•0" IVo_ 13.4y' 13'-5' 2/180 B'-6' 9'-f0" 11'-7" 11'•6' 14••0• 14'•5' 30 Ps1 L1240 7'-0" B'-11'• 1a-6' 10'6" 12'•0" 13'•1" L/180 0'•4" B'•7" 11••4•. 1t•j'. 17'fl 111•-_. 32 pct Ll240 T-7" 0'-0" ta•3' 10'•3"_. _ t2'-6'.--.--12.40" L/180 0'•2" 9'S" 11•,1• 11'-i' 13,,5" 13•,16•, 34 psf 2/2.40 7.5' 7" B'-- 10,•1 19'•1_ 12'•3" 12 '•7" L/1600 T•11" B'•2" 10'•U` 10'-9' U'•1" 135" 37 psf L 12.10 T.2" 8'•4" 9-10" 1T-9' II'•I I' 12'.2" L / 180 T-9" 8'-11" 10'•6' 10'•B"12.7' ITA, 40 psf 2/240 T-6" 6'-1" a47, 0'-6- 11.7" 11'41" L/160 G., B.•B. tU.•2,1ry.2^ 12.•4.. t7.0.. 44 psf L/240 W-10" 7'•10" i-3" 7'-3" I1',6" L/100 78 7'-3" B'-5" 8'•11' 9'•10" I1'•12" 1214` D'+f L 1240 G'•i" T -V' 0'.11" 10'•11" L / 180 7'•1" B'•2' 8.,12' 7.7' a•T" 11'•6' 11'•1a' 52 PSI LI240 G'•5" T•5" 0'-a' 6'-0' IV.! 16'•1.1'... L1100 11, TAT' 0'•5" U' -i' 11 5 11'•:," SG P51 L 1'240 13%3" T•3" Tt.'. 0'-G" 1a•4" l t0U 6' U" T•10" B 9'•2" V-7: N'•2" 11'•71" 118" GO PSI 21240 G'-2" 1'• 0'••I" 0'•A" la•I• tU<F DEFLECTION NOTES: 1, USE L/120 FOR ALL MEMBERS SUPPORTING ROOFS OVER AN OPEN OR SCREEN -WALLED LOOM, 2. USE L/180 FOR ALL MEMBERS SUPPORTING ROOFS WITH A NON -PLASTERED CEILING OVER AN ENCLOSED ROOM. 3 ENCLOSED ROOM, PER IFLLOR DA BUILDING CODE ERS SUPPORTING FFIFTH EDITION ( 201S WITH A DCEILING N USE L/240 FOR ALL )TA13 E 1604 3n MAXIMUM ALLOWABLE DESIGN PRESSURES: AS NOTED IN CLEAR SPAN TABLES DESIGN NOTES: THIS SYS EM SHALLTBE DETvE ERMINED BY OTHERSLON A )OB --SPE IF CTED FOR USE WITH BASIS IN ACCORDANCE WITH THE GOVERNItJG CODE. SITE•SPECTH APRESSUREREQUIREMENTSASDETERMINEDINACC00.DANCE WITN ASCE 7.10 AND CHAPTER 1609 Of THE FLORIDA BUILDING CODE FIFTH EDITION 2014) SHALL BE LESS TIIAIJ OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. GENERAL NOTES: I. THIS SPECIFICATION HAS BEEN DESIGNED AND SHALL BE 3, THE ARC! SUPERSTRUCTtRESPONSIBLE THIS DESIGN V CONTRACTOR, 4. SEPARATi REQl""ED IN C CONTAINED HE TABLES LISTF.0 ENGINEER FOR 5. THE SYSI INFORMATION FROM THE CON REGISTERED A USE IN CONIUI G. TILE CON LOADS ON RO( LOADS WHICH ADDITIONAL R LICENSED ENC 7. EPS COR CHAPTER 7 SECTION 720, 115H. AND CHAPTER 215 WHICH Y. INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THIS SYSTEM. ITER/ENGINEER OF RECORD FOR THE PROJECT tE WITH 1'1Hicii THISDESIGN IS USED SHALL BE RCH SHALL BEINTEGRITY THE COORDINATED BY THE PERMITTING TO SITE-SPECIFIC' SEALED ENGINEERING SHALL BE IIN. UNE RI NTERPOILATION 0 DTI E ALLOWABLE SPANS HEREIN SHALI NOT BE PERI4ITTOL, CONTACT THIS n 1—fATF aPAN CALCULATIONS AS 14AY BE REQUIRED. OF 1 BY OTHER CONSIDERATIONS: BEYOND THAT WHICH IS CALLED FOR E 111110 M DEVIATIONS OF Th1I5 PLAN. FIFRONT OVERHANGI.1AY DEUPTO 3'•0" WITH VALUES LISTC•D I7E(tE1N. 14AXIMUM 10. EXCEPTAS EXPRESSLY PROVIbE[ SUPPORTED SDE OVERHANG IS 2546 OF LAST PANEL WIDTH (I.O. 12" MA% FOIt 48" CERTIFIG\TIONSORAFFIRMATIONS AI IJEL WIDTH). El. ALT[RTIONS, ADDITIONS, HIGI OF PITCH Sh1ALL OE AS PER BUILDING_CODE REQUIREMENTS __,____! THIS DOCUMENT ARE NOT PERMITTED CERTIFICATION. OPTIONAL GUTTER OR DRIP CAP PANEL-/ OVERHANG -1 DEPTH 36" MAX O/H AT FRONT & 25% 1 OF LAST PANEL WIDTH AT SIDES UP TO 12" MAX O/H AT SIDES) CONSIDER POSSIBLE IMPOSING ITED TO ANY CONCENTRATED GN CRITERIA, THIS 3E PROPERLY ANALYZED BY A I ITECT. BE CONSTRUCTED USING TYPE T POLYSTYRENE FOAI4 SHALL ALL BE MANUFACTURED BY NOA # 11.0926.07 (OR FOAM SHALL BE ADHERED TO 202 ADHESIVE (BY ASHLAND CORDANCE WITH APPROVED It FOR ALI. PANELS. 0 INSULATE OR PROTECT ALL 0 PREVENT ELECTROLYSIS. 1LIDATES STRUCTURAL DESIGN TION BY CONTRACTOR, et. al. iGINEER FOR ALL COST & LATE FEES.RESULTING FROM IN, & CONSTRUCTION PRACTICES OCAL, STATE, & FEDERAL CODES REIN, NO ADDITIONAL WENDED. IHTING. OR OTHER MARKINGS TO TABLE VALUE DERIVATIONS: PANEL PROPERTIES: 1. PANEL STRUCTURAL PROPERTIES DERIVED FROM CERTIFIED TEST REPORTS Nos. HETI-05-1985, •05.1907, •05-1980, •05-1909, 05-1990, •OS -1991,•05.1992, -05.1993, -05.1994,-05-1995, OS -1996, •05.1997, •06.2066, -06•2067, •06•2068, -06-2069, 06.2070 '06.2071, -06-2072, -06.2073, & •06.7.074 BY HURRICA{ E ENGINEERING & TESTING, Inc. 2. PANEL DEAD LOADS RAVE BEEN FACTORED INTO CALCULATIONS FOR GRAVITY LOADS AS WELL AS CALCULATIONS FOR PANEL PROPERTIES. 14-1438 City of Sanford Aluminum Structures Permit Application Checklist All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. Copy of a contract, signed by the contractor and the property owner, indicating the documented construction value of the project. Copy of applicable contractor's license issued by the State of Florida. A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). Completed and Signed Owner Builder Statement / Affidavit (if the owner is the applicant). Two (2) site plans indicating proposed location. Two (2) copies of the signed and sealed engineered drawings. Wind design data required on drawings per FBC 1603.1.4 to meet 129 mph ultimate design wind speed for risk category I buildings OR Two (2) copies of previously mastered filed plans. Indicate all details and options that apply. Two (2) copies of a site specific layout for the structure with minimum 1/8" per foot scale. Include all framing sizes and types. Include any electrical devices to be added. Two (2) copies of Florida Product Approval, including manufacturer installation instructions and product evaluation reports, for composite or elite roofing systems. (If applicable) t1 For Sunrooms — must designate specific Sunroom Category on the signed and sealed plans, in accordance with FBCR R301.2.1.1.2 Contact Person information entered in Naviline? Application forms stamped received and initialed Revised: February 2015 City of SanfordFD Aluminum Structures Permit Application Checklist a ag All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: VllBuilding Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. 6d' Copy of a contract, signed by the contractor and the property owner, indicating the documented construction value of the project. V/ Copy of applicable contractor's license issued by the State of Florida. A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). Completed and Signed Owner Builder Statement / Affidavit (if the owner is the applicant). V/ Two (2) site plans indicating proposed location. Two (2) copies of the signed and sealed engineered drawings. Wind design data required on drawings per FBC 1603.1.4 to meet 129 mph ultimate design wind speed for risk category I buildings OR Two (2) copies of previously mastered filed plans. Indicate all details and options that apply. Two (2) copies of a site specific layout for the structure with minimum 1/8" per foot scale. Include all framing sizes and types. Include any electrical devices to be added. V/ Two (2) copies of Florida Product Approval, including manufacturer installation instructions and product evaluation reports, for composite or elite roofing systems. (If applicable) For Sunrooms — must designate specific Sunroom Category on the signed and sealed plans, in accordance with FBCR R301.2.1.1.2 These guidelines were compiled to assist the applicant in preparing an aluminum structure permit application and may not be complete. The applicant is required to meet all City of Sanford, state, and federal code requirements. Revised: February 2015 REQUIRED INSPECTION SEQUENCE BP# /L -a'?" Address: T&Z- M+ 4V>eA4L REVISED: June 2014 ELEcTRIcAL PERMI ¢' Min Mays Ins2ection llDescri tion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final Min Max Ins ection llDescri tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MECHANICAL PERMIT Min Max Inspection tDescri tion Mechanical Rough Mechanical Final Min Mays Ins ection Descrilgtion Gas Underground Gas Rough Gas Final