HomeMy WebLinkAbout2834 Empire Pl5 7 p Ir CITYCITY OF SANFORD BUILDING & FIRE PREVENTION OC PERMIT APPLICATION By M.Y 1 i Application No: Documented Construction Value: $ 500.00 Job Address: 2834 Empire Place Historic District: Yes No Parcel ID: 06-20-31-505-OD00-0020 Residential Commercial Type of Work: New Addition Alteration Repair R Demo Change of Use Move Description of Work: Replace permit # 05-1716 Plan Review Contact Person: A ac r j/IJyl Title: PhoneF/", 9 V _ OoFax: Email: ., cr [ -30 rfnqj1 Property Owner Information yghoo'Com Name Bonne Aventure LLC Street: 3900 Fern Forrest Road City, State Zip: Name Mark Orman Street: 117 Georgetown Dr. Suite A Phone: 774-272-0532 Resident of property? : Contractor Information Phone: 321-945-2500 Fax: 407-209-3560 City, State Zip: Casselberry, FL 32707 State License No.: Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: Mortgage Lender: Address: CCC1327051 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code \ Revised: June 30, 2015 Permit Application \ NOTICE: In. addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Si a r f wn r/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Sign re o Contractor/A ent Date r Print Contractor/Agent's Na ie Signature of N pRY a' ANNETTE SCOTT r,• •`: Notary Public . State of Florida MY Comm. Expires Jan 16. 2018f•" E „orCommission # FF 071760 Bonded 11vg gry Natlarral Notary Assn. Contractor/Agent is Personally l_iio'Tn'01MN or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[:] Gas F] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures of Heads Fire Alarm Permit: Yes No UTILITIES: WASTE WATER: FIRE: BUILDING: Revised: June 30, 2015 Permit Application MARK. ORMAN CONSTRUCTION Mark Orman, General Contractor, Owner 117 Georgetown Dr. Suite A, Casselberry FL 32707 Phone: 407-629-6640 Fax: 407-209-3560 E-mail: markjorman@yahoo.com General Contractor Lic. # CGC 1506674 Roofing Contractor Lic. # CCC1327051 LIMITED POWER OF ATTORNEY By virtue of this docu nnent I, Mark Orman, Licensed General Contractor CGC 1506674, Licensed Roofing Contractor #CCC 1.327051, hereby authorize Darrell Taft to sign any and all docurnents to pull a permit at this address: 2834 Empire Place, Sanford FL Contractor's signature Mark Orman nate STATE OF FLORIDA COUNTY OF SEMINOLE The foe ing instrument was acknAdg before me on this 7 day of G_ , 2016, by e k le -e -a- who is i personally known, or [ ] produced a Florida driver license to me. PAULETTE L. GORY Seal: MY COMMISSION # FF103004 EXPIRES: June 11, 2018 i Notary signature Page 1 of 4 RECORD COPY BCIS Home Log In i User Registration Hot Topics Submit Surcharge Stats & Facts Publications 1 FBC Staff 1 BCIS Site Map Links Search Product Approval USER: Public User lu a Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16270-R3 Application Type Revision Code Version 2014 Application Status Approved LICENSE TO PROCEED WITH THE WORK AND NOT AS Approved by DBPR. Approvals by DBPR shall be reviewed and ratified David G. Allen by the POC and/or the Commission if necessary. Address/Phone/Email REVIEWED FOR CODE COMPLIANCE Comments Archived I PLANS EXAMINER Product Manufacturer BITEC, INC. lQ'1`:2- 1 W— Address/Phone/Email 2 Industrial Park Drive DATE P.O. Box 497 CONSTRUCTION OR VIOLATIONS OF THIS CODE Morrilton, AR 72110 501)354-8585 Address/Phone/Email dga@bi-tec.com Authorized Signature James Buckner SANFORD BUILDING DIVISION jimmy@cbuckinc.net A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS Technical Representative David G. Allen AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET Address/Phone/Email 2 Industrial Park ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL PO Box 497 CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT Morrilton, AR 72110 THE BUILDING OFFICIAL FROM THEREAFTER dga@bi-tec.com REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By James L. Buckner, P.E. at CBUCK Engineering W Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year UL 1897 LDING 2004 UL 580 2006 SANFORD Equivalence of Product Standards c Certified By AR-6 16-2 8 Product Approval Method Method 1 Option A Date Submitted 05/12/2015 10/13/2016 Page 2 of 4 Date Validated 05/12/2015 Date Pending FBC Approval Date Approved 05/20/2015 Summary of Products FL # Model, Number or Name Description 16270.1 01 - "APM-4T", APM-4.5T", Bitec APP/SBS Modified Bitumen Roof Systems, adhered SPM -4.5T", "ISA -4T" or "Mineral over mechanically -fastened, Non -insulated Wood Deck, Heat Design MDA" fused per System #1 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -60 Other: Refer to Certification & current edition of FBC for Limitations and Conditions of use. Refer to Manufacturer's Installation Instructions as Supplemental Guide. Certification Agency Certificate FL16270 R3 C CAC UL TGIK R13231.pdf Quality Assurance Contract Expiration Date 08/30/2018 Installation Instructions FL16270 R3 II UL TGIK R13231.1)df Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 16270.2 02 - "SFM-3.5H", SFM-3.5H-FR' , SFM-4H-FR", "SPM -3.5H" or Mineral Design MDS" Bitec APP/SBS Modified Bitumen Roof Systems , adhered over mechanically -fastened, Non -insulated Wood Deck, Hot Mopped per System #1 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16270 R3 C CAC UL TGIK.R13231.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 08/30/2018 Design Pressure: +N/A/ -60 Installation Instructions Other: Refer to Certification & current edition of FBC for FL16270 R3 II UL TGIK.R13231.odf Limitations and Conditions of use. Refer to Manufacturer's Verified By: UL LLC Installation Instructions as Supplemental Guide. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 16270.3 03 - "APM-4T", APM-4.5T", SPM -4.5T", "ISA -4T" or "Mineral Design MDA" Bitec APP/SBS Modified Bitumen Roof Systems adhered over mechanically -fastened, Insulated Wood Deck, Heat fused per System #2 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16270 R3 C CAC UL TGIK.R13231.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/30/2018 Design Pressure: +N/A/ -52.5 Installation Instructions Other: Refer to Certification & current edition of FBC for FL16270 R3 II UL TGIK R13231.odf Limitations and Conditions of use. Refer to Manufacturer's Verified By: UL LLC Installation Instructions as Supplemental Guide. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 16270.4 04 - "SFM-3.5H", SFM-3.5H-FR", SFM-4H-FR", "SPM -3.5H" or Mineral Design MDS" Bitec APP/SBS Modified Bitumen Roof Systems, adhered over mechanically -fastened, Insulated Wood Deck, Hot Mopped per System #2 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16270 R3 C CAC UL TGIK.R13231.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/30/2018 Design Pressure: +N/A/ -52.5 Installation Instructions Other: Refer to Certification & current edition of FBC for FL16270 R3 II UL TGIK.R13231.pdf Limitations and Conditions of use. Refer to Manufacturer's Verified By: UL LLC Installation Instructions as Supplemental Guide. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 16270.5 05 - "APM-4T", APM-4.5T", SPM -4.5T", "ISA -4T" or "Mineral Design MDA" Bitec APP/SBS Modified Bitumen Roof Systems, adhered over mechanically -fastened, Insulated Wood Deck with Barrier board, Heat fused adhesive per System #3 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16270 R3 C CAC UL TGIK.R13231.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/30/2018 Design Pressure: +N/A/ -67.5 Installation Instructions Other: Refer to Certification & current edition of FBC for FL16270 R3 II UL TGIK.R13231.1)df Limitations and Conditions of use. Refer to Manufacturer's Verified By: UL LLC Installation Instructions as Supplemental Guide. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 16270.6 10/13/2016 Page Bottom TGIK.R13231 Roofing Systems, Uplift Resistance Roofing Systems, Uplift Resistance See General Information for Roofing Systems, Uplift Resistance BITEC INC 2 INDUSTRIAL PARK DR PO BOX 497 MORRILTON, AR 72110 USA SINGLE PLY MEMBRANE SYSTEMS 1. Uplift Resistance: 120 psf. R13231 Deck: — Minimum 15/32 in. thick APA rated sheathing, 32/16. Base Sheet: — One ply Type G2 "Glasbase", "FS -21-l", "Imperflex MSA", "Imperflex USA", "DEFEND", "MAT -40" or "UDL-40" mechanically attached to deck with steel cap -nails. Cap 1 in. diam, 0.032 in. thick with annular ring shanked nail 0.120 in. diam, 1-1/2 in. long. Nails spaced 7-1/2 in. OC along 4 in. side lap and 12 in. OC in two interior rows located 11 in. from exposed edges of side laps. Membrane: — "APM-47", "APM-4.5T", "APS -4T', "SPM -4.5T", "ISA -4T" or "Mineral Design MDA", heat fused. "SFM-3.5H", "SFM-3.5H-FR", SFM-4H-FR", "SPM -3.5H" or "Mineral Design MDS", hot mopped. 2. Uplift Resistance: 105 psf. Deck: — Min 15/32 in. APA rated sheathing, 32/16 or nom 2 in. by 6 in. wood planking. Insulation: — Any polyisocyanurate, perlite or wood fiber, any thickness. Base Sheet: — One ply Type G2 "Glasbase", "FS -21-l", "Imperflex MSA", "Imperflex USA", "DEFEND", "MAT -40" or "UDL-40" mechanically attached to deck with annular ring shanked nails 0.148 in. diam used with a separate 3 in. diam, 0.021 in. thick formed disc. Nails spaced 7-1/2 in. OC along 4 in. side lap and 12 in. OC in two interior rows located 11 in. from exposed edges of side laps. Nails to penetrate plywood min 1/2 in. and wood planking min 1 in. Membrane: — "APM-4T", "APM-4.57", "APS -4T", "SPM -4.57, "LSA -47 or "Mineral Design MDA", heat fused. "SFM-3.5H", "SFM-3.5H-FR", SFM-4H-FR", "SPM -3.5H" or "Mineral Design MDS", hot mopped. As an alternate for fastening to plywood, No. 12-12.5, No. 3 phillip drive, trusshead or 1/4 in. hex -washer -head coated steel screws may be used with the same pressure plate and spacing as for nails. Screws to penetrate plywood min 1/2 in. As an alternate for fastening to wood planking, No. 14-10, No. 3 phillips drive, trusshead or 1/4 in. hex -washer -head coated steel screws may be used with the same pressure plate and spacing as for nails. Screws to penetrate planking min 1 in. 3. Uplift Resistance: 135 psf. Deck: — Minimum 15/32 in. thick Type B -C rated plywood sheeting. Insulation: — Polyisocyanurate, perlite or wood fiber, any thickness. Barrier Board: — Minimum 1/2 in. thick G -P Gypsum Corp. "DensDeck ® Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck Prime 2— Roofboard" or "DensDeck DuraGuard@ Roofboard" or Certainteed Gypsum Inc "GlasRoc" or USG Corp. SECUROCK® Glass -Mat Roof Board (Type SGMRX)". Fasteners: — No 14 threaded screws with min. 3 in. diameter, 0.021 in thick galvanized steel round plates, min. 1 fastener per 1 square foot. Base Sheet: — One ply Type G2 base sheet, fully adhered. Membrane: — "APM-4T", "APM-4.5T", "APS -47", "SPM -4.5T", "ISA -4T" or "Mineral Design MDA", heat fused. "SFM-3.5H", "SFM-3.5H-FR", SFM-4H- FR", "SPM -3.5H" or "Mineral Design MDS", hot mopped or adhered with cold applied adhesive. 4. Uplift Resistance: 120 psf. Deck: — Steel, min 22 MSG. Insulation: — Polyisocyanurate, perlite or wood fiber, any thickness. Barrier Board: — Minimum 1/2 in. thick G -P Gypsum Corp. "DensDeck O Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck Prime 21" Roofboard" or "DensDeck DuraGuard@ Roofboard" or Certainteed Gypsum Inc "GlasRoc" or USG Corp. SECUROCK® Glass -Mat Roof Board (Type SGMRX)". Fasteners: — No 14 threaded screws with min. 3 in. diameter, 0.021 in thick galvanized steel round plates, min. 1 fastener per 1 square foot. Base Sheet: — One ply Type G2 base sheet, fully adhered. Membrane: — "APM-4T", "APM-4.57", "APS -4T", "SPM -4.5T", "ISA -47" or "Mineral Design MDA", heat fused. "SFM-3.5H", "SFM-3.51-1-FR", SFM-4H-FR", "SPM -3.5H" or "Mineral Design MDS", hot mopped or adhered with cold applied adhesive. 5. Uplift Resistance: 225 psf. Deck: — Concrete (cellular, gypsum, vermiculite, perlite or structural). Insulation: — — Polyisocyanurate, perlite or wood fiber, any thickness, adhered with ADCO "Millenium One Step" adhesive. Barrier Board: — Minimum 1/2 in. thick G -P Gypsum Corp. "DensDeck @ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck Prime 211 Roofboard" or "DensDeck DuraGuard@ Roofboard" or Certainteed Gypsum Inc "GlasRoc" or USG Corp. SECUROCK® Glass -Mat Roof Board (Type SGMRX)", adhered with ADCO "Millenium One Step" adhesive. Base Sheet: — One ply Type G2 base sheet, hot mopped, or adhered with cold applied adhesive. Membrane: — "APM-4T", "APM-4.57", "APS -4T", "SPM -4.5T", "LSA -47" or "Mineral Design MDA", heat fused or "SFM-3.5H", SFM-3.5H-FR", "SFM-4H-FR", "SPM -3.5H" or "Mineral Design MDS", hot mopped or adhered with cold applied adhesive. Last Updated on 2013-07-24 Ouestions? Print this page Terms of Use Pace Top 2015 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2015 UL LLC". Ito_a1;?-5 WAYNE GANDY, P.E. -- CIVIL ENGINEER 720 S. ORANGE BLOSSOM TRAIL ORLANDO, FLORIDA 32805 321) 297-8635 FEBRUARY 24, 2017 CITY OF SANFORD BUILDING DEPARTMENT SUBJECT: ROOF CONSTRUCTION CERTIFICATION 2834 EMPIRE PLACE (PERMIT NO. 1 62728) SANFORD, FLORIDA THIS LETTER IS TO CERTIFY THAT I HAVE INSPECTED THE ROOF CONSTRUCTION PERFORMED AT THIS ADDRESS AND HAVE FOUND IT TO BE ACCEPTABLE PER THE FLORIDA BUILDING CODE. PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS OR REQUIRE ANY ADDITIONAL INFORMATION. THANK YOU. SINCERELY, \``\\y P.Nc NO. 33134 STATE OF 7// SS/ONALWAYNEGANDY, P. e. FLA. P.E. No. 33134 Digitally signed by Wayne Gandy Date:„2017.02.27 12:47:02 -05'00' vJ'QING D SAN OR CIVIL ENGINEERING * PLANNING * PROJECT MANAGEMENT WAYNE CANDY, P.E. -- CIVIL ENGINEER 720 S. ORANGE BLOSSOM TRAIL ORLANDO, FLORIDA 32805 321) 297-8635 NOVEMBER 1 4, 2016 Nov 15 2016 CITY OF SANFORD BUILDING DEPARTMENT - ORLANDO, FLORIDA RE: CERTIFICATION OF ROOF CONSTRUCTION 2834 EMPIRE PLACE (PERMIT # 16-2728) SANFORD, FLORIDA THIS LETTER IS TO CERTIFY THAT I HAVE INSPECTED THE ROOF CONSTRUCTION PERFORMED AT THIS ADDRESS AND HAVE FOUND IT TO BE ACCEPTABLE PER THE APPROVED PLANS AND THE FLORIDA BUILDING CODE. PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS. CONS` REE G 0F ' rr V gkyt E N E. •` ` FP.E.'iVO. • ` . 3ES:S101` 0g` CC: SIDNEY DILLON THANKS FOR YOUR APPROVAL OF THIS C:\USERS\OWNER\DESKTOP\WAYNE\1- PROJECTS\ 1- ACTIVE\ 1-DESIGN\2834 EMPIRE PLACE\ 1 1 1416- CERTIFICATION LTR -2834 EMPIRE PLACE\ CIVIL ENGINEERING ' PLANNING ' PROJECT MANAGEMENT WAYNE CANDY, P.E. -- CIVIL ENGINEER 720 S. ORANGE BLOSSOM TRAIL ORLANDO, FLORIDA 32805 321) 297-8635 NOVEMBER 14, 2016 NOV 5 2018 CITY OF SANFORD BUILDING DEPARTMENT ORLANDO, FLORIDA RE: CERTIFICATION OF ROOF CONSTRUCTION 2834 EMPIRE PLACE (PERMIT # 16-2728) SANFORD, FLORIDA THIS LETTER IS TO CERTIFY THAT I HAVE INSPECTED THE ROOF CONSTRUCTION PERFORMED AT THIS ADDRESS AND HAVE FOUND IT TO BE ACCEPTABLE PER THE APPROVED PLANS AND THE FLORIDA BUILDING CODE. PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS CONSII c- i0 '3 •• v Lli 1VAA E P A • • Com" : 0. CC: SIDNEY DILLON THANKS FOR YOUR APPROVAL OF THIS 0- 114-116 e':e C:\USERS\OWNER\DESicroP\WAYNE\1-PROJECTS\i-ACTIVE\1-DESIGN\2834 EMPIRE PLACE\ 1 1 1416- CERTIFICATION LTR -2834 EMPIRE PLACE\ CIVIL ENGINEERING ' PLANNING ' PROJECT MANAGEMENT