Loading...
HomeMy WebLinkAbout1600 W 5 St Building 2CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: /(0' 3 a .� Documented Construction Value: $ I O�p, D, • D_ Job Address: ISE. Historic District: Yes ❑ No Parcel ID:3 5 " -D • `j -0 Residential Commercial] Type of Work: New Addition ❑ Alteration 11 - Repair ElDemo ❑ Change of Use❑ Move ❑ Description of Work: NAO-n - roUltC' d UA Yl in &y- ax)a ► trn S Plan Review Contact Person: l Title: hd "ly\ Phone: 25.5 - Db4fFax: `35a ' `-(" (�Aail: fII -f—A l Property Owner Information Name sf s (� j2a-" ff"-b L.� Phone: Street: 5 L4 0 3 W. UyaL4 S+ • Resident of property? : nn City, State Zip: T 3 l.e Contractor Information Name Phone: 35a-1ga - ec Street: PO Q(7x (-D3q Fax: -�Sa- G14U- I c --)o3 City, State Zip: �i�, �%� 1, , �--G VAbQ6 State License No.: C CC 1 3 30l l,o Cn Architect/Engineer Information Name: Phone: ' Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR 0-� PAYING TWICE FOR RVIPROVEMIM TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WrM YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COb9dENCE14ENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, ping, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc FBC 1853 Shall be inscribed with the date of application and the code in Bred as of that date: 56 Edition ("14) Florida Building Code Revised: June 30, 2015 Permit Applicitim NOTICE: In addition to the requirements of this permit, there may he additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The -City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 11u . fz) (A f fc0 TARA L FIGUEROA ;F`'' ;' TARi42�IGUEROA • MY COMMISSION # GG044967 _ MY COMMISSION # GG044967 • •M a EXPIRES November 03, 2020 EXPIRES November 03. 2020 4i, - Owner gent is ersonally Known to Me or Contractor/Ais Personally Known to Me or gent Produced ID Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas❑ Roof,+® Construction Type: Occupancy Use: Flood Zouei Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories New Construction: Electric - # of Amps Plumbing - # of. Fixtures Fire Sprinkler Permit: Yes❑ No ❑ # of Heads Fire Alarm Permit: Yes®r:INo�O APPROVALS: ZONING: UTILITIES: WASTE WATER lomw ENGINEERING: FIRE: ••.� COADIENTS: Revises: hme 30, 2015 BUILDING 12 -P Pamir,4pplicatim a PERMIT # /( � 2P 7:5-r-_ Quote To: DAVID JOHNSON qqq ABC Supply Co., Inc. #509 600 Ponce DeLeon Blvd. Brooksville, FL 34601 bbbbbb.- Phone #: 352-754-1018 TA P E R E D Fax #: 352-754-1019 Customer: JAMES @ FOSTER ROOFING SOLUTIONS General Project Information: Date Quoted: 2/22/2016 1542 Apex Rd. Job Name: 1066 W 5th ST - BLDG. 2 Sarasota, FL 34240 TEL: 800-827-3702 FAX: 866-934-5059 Location: SANFORD Job #: BE -98557 -B -X3 Proiect Manager. Tom Bermingham E -Mail: tom.bermin ham abcsu ply.com Tapered System Description: Material: ISO Cricket Material: N/A Tapered Area (sq): 87.68 Cricket Area (sq): 0 Slope: 1/4" Cricket Slope: N/A Minimum Start: 3.00" (1.5" +BASE) Cricket Fill: N/A Maximum Thick: 7.38" Cricket Max. Height: N/A Fill Insulation: 2" ISO Base Layer: Overlay: Avg. R -Value: Min. R -Value: Notes: 1.5" ISO - INCLUDED N/A 26.0 17.4 Total Sqs. Applied: 234.72 Total Sqs. Material: 252.00 Total ISO Truckloads: 1.13 PERLITE Truckloads: 0.00 Price: Valid if shipped by: IMAGE SHOWN ABOVE REFLECTS ABC'S DESIGN INTENT - ALL SUBMITTALS ARE SUBJECT TO ARCHITECT / CONTRACTOR APPROVALS. IMPORTANT - As a supplier of materials only, ABC Supply does not assume responsibility for errors in design, engineering, quantities or dimensions. Architect and/or contractor shall verify all drain locations, perimeter dimensions, sizes, materials and R -values. Contractor is responsible for verifying this quote to Insure that it meets job specifications. All shop drawings must be approved prior to material shipment. Foster's Roofing Enterprises �352-799-0045 Florida License No #•CCC1330166 Revised Bid Date: 9/8/16 15 .50 SLA'r�— AVC- l "-t Project-a'Semiriole:Gar•'dens'--- 1 Lt-el;rL- '24(pD'-{ Location: 1600 W 51' St. Sanford, FL 32771 Client: Vaughn Bay Construction 352 a-7�'1 3sa� Proposal based on drawlings dated 2/12/16 and satellite measurements Price includes: All required insurances, workers compensation, materials, labor, Manufacturer Standard Warranty 20 year TPO membrane warranty, and Foster's Roofing 5 year leak free workmanship warranty. Permitting and engineering fee's additional, if required. 20 year Flat roof Scope: 5 Apartment Buildings and leasing office • Remove existing flat roofs down to concrete deck • Furnish and install'/. inch tapered ISO insulation, 3 Inch minimum start (fully adhered) • Furnish and install 60mil TPO, fully adhered • Furnish and install all needed accessories: boots, vents, termination bar, etc. • Furnish and install new drip edge and wood nailer to match insulation height at leading edges. 560 Sq. ® $813.69 per Sq. Cost: $455,667.80 Optional: 20 Year NDL Warranty------- $9,400.00 30_lyearrMjfgoofiScope:5 PET—"%W-"l- and!leasin ce ,,.�..•- • Remove existing flat roofs down to concrete deck • Furnish and install'/. inch tapered ISO insulation, 3 inch minimum start (fully adhered) • - Furnish and install 80mil TPO, fully adhered • Furnish and install new TPO clad drip dge • Furnish and install all needed accessories: boots, vents, termination bar, etc. • Furnish and install new drip edge and wood nailer to match insulation height at leading edges. os 0 .80 101 ear 'clue Foster's Confidential TRINITY ERD - TABL•E•_4A::UGH•T..WEIGFRCONCRETE:DECIGS•- NEW.CONSTRUCTIONIDMRER00F,NEAR-OFE} e SYSTEM:TYPE-X-I:. BONDED.INSUWTION,3BO.NDED)ROOFCGV/ERo "-�- - Deck (See Note 1) Base Insulation Layer Coverboard System No. Roof Cover/ Adhesive MDP (psi) Struct Deck LWIC (See Note IS) Type Attach Type Attach Min. 200 psi, min. 2 -inch (Optiona)) Min. 1.5 -inch EnergyGuard RA, Min. 0.2S4nch Dens Deck Prime LWC-27. Concrete thick Celcore Cellular EnergyGuard RH or EnergyGuard RN, min. 1.5 -Inch GAF 2 -Part or SECUROCKGypsum•Fiber Roof GAF 2 -Part EverGuard TPO / L-VOC, -05.0 Concrete, Elastizell or thick, min. 1.25 pcf density ASTM CS78 expanded or Board TPO 3 -Square Mearlcrete extruded EPS board LfAfC-26. Concrete Min: 200'psi; min. 2 -inch Min: LS -Inch EnergyGuard Polyiso Insulation, GAF 2=Part. (Optional)•Additional+layer of. GAF'2=Part. : EverGuardTPO / LcVOC,. ' ; thick Elastizell EnergyGuard Ultra base Insulation TPO'3=Square- LWC-29. Concrete Min. 200 ps4 min. 2 -Inch thick Celcore Cellular MIn.1.5-Inch EnergyGuard Polyiso Insulation GAF 2 -Part (Optional) Additional layer of. GAF 2 -Part EverGuard TPO / L-VOC, -222.S Concrete EnergyGuard Ultra base Insulation TPO 3 -Square [. FLW30 Concrete Min. 20D psi, min. 2 -inch i Min. 1.S -inch EnergyGuard Polylso Insulation, GAF 2 -Part (Optlorial) Additional layer of GAF 2 -Part I EverGuard TPO / L-VOC, -240 0 thick Mearlerete EnergyGuard Ultra I base insulation TPO 3 -Square Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report 01506.09.05-R23 for FLS293-1122 Certificate of Authorization 09503 Revision 23: 04/11/2016 -Prepared by: Robert Nieminen, PE -59166 Appendix 1, Page 61 of 8S Category/ Subcategory Manufacturer Product Description Florida Approval # including decimal 3. Panel Walls Siding Soffits Storefronts ' Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation 0 4jr ISO 10 OC� l WA` Waterproofing Built up roofing System Modified Bitumen Single Ply Roofv Systems A F e,r uQ aD ILA g -00 Roofing slate _ Cements/ Adhesives / Coating Liquid Applied Roofinig Systems Roof -rile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 INSPECTION SEQUENCE BP# 16-3274 ADDRESS: 1600 W. 5" Street BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Ins ection Building Ceiling Air Barrier 10 Insulation Roof Com'1 Building Ceiling Grid 1000 Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Farnfly Residence Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) REVISED: June 2014 ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final s Min Max Inspection Description Rough Plumb Plumbing Underground Plumbing 2nd Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final