HomeMy WebLinkAbout306 Loch Low Line7 2016 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 1 & - �b g 68 Documented Construction Value: $ g. 000 Job Address: 306 LOcti LOW W <AA0rn/LL 32773Historic District: Yes ❑ No ❑ Parcel ID: 10- Zo - 3 o , S C - os o - oo y O Residential [Commercial ❑ Type of Work: New Ef Addition 9 Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Lodl cr-e.+-, Plan Review Contact Person: &I I t.c,1+e,- I ke,u 1 n Title: Phone: Y01- 678 -OS coo Fax: Yo7- G its --5S6u Email: i� ► I (y w c-_-) S v1, - FI- c.o u (A'M10„0 Property Owner Information Name %o�y 'Petra hi-,' Phone: Ll�31d 2Z! Street: Set: _ Lech Lyj L ne Resident of property?: yeS City, State Zip: 5,k A, ,5 Pe- ?Z773 01 Contractor Information Name -fiat 011'e- l_5y0qr.pr Phone: AOIC7 I' - O 5-0 a Street: 30os 1;r6a9 rad • Fax: y6 J '-C 7ff -Y-5-C43 City, State Zip: 0#4tr- .71-74'Z State License No.: SGLo_srG 7 76 Q Architect/Engineer Information Name: 1 ' ' G": d L Phone: Street: 4✓ / A Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. l certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5t° Edition (2014) Florida Building Code Revised: June 30, 2015 Pennit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, andithere may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of pennit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Z�07' ge%/%/ --z ZOId Signature o wner/A ate Signature of Contractor/Agent Date tl� r4 Ple 1 Pnnt Owner/Agent'g Name P ntractor/Agent's N e r ure of No =fa flonda -• Isr'*IA a e 4 ,r'pv oVq'' ,, o,av ,, JESSIE SANIIAGO +°• •�` Notary Public State o1 Florida •I,. My Comm. Expires Sep 2, 2017�•.` = Notary Public State of Florida +, �? Commission # FF 050565 is moo; My Comm. Expires Sep 2.2017 of •�,,• aOv n o,, Commission # FF 050565 n„a , Owner/Agent is Perso or Contractor/Agent is ersonall Known to a or ProducedD yp Produced ID Type o BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas[] Roof ❑ Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads Fire Alarm Permit: Yes ❑ No ❑ Jots• APPROVALS: ZONING: `Z—���LGs� UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Ok to install screen room with concrete as shown on plan. Meets area and dimension regulations for SR - 1A zoning district. Revised. June 30, 2015 Permit Application SCPA Parcel View: 10-20-30-5CT-OJ00-0040 Page 1 of 2 • Property Record Card Cane Mem. CFA Parcel: 10-20-30-5CT-OJ00-0040 ANWR Owner: PERROTTI ANTHONY JR & TERESA scn�s�o`ecouxn r•�a+la^ Property Address: 306 LOCH LOW LN SANFORD, FL 32773 Parcel Information Parcel 10-20-30-5CT-OJ00-0040 Owner PERROTTI ANTHONY JR & TERESA Property Address 306 LOCH LOW LN SANFORD, FL 32773 Mailing 306 LOCH LOW LN SANFORD, FL 32773-5506 Subdivision Name HIDDEN LAKE UNIT 1-C Tax District S1-SANFORD DOR Use Code 01 -SINGLE FAMILY Exemptions 00-HOMESTEAD(2010) + 1156 4�S S r07.95 �O� N M Off• 3 ti 111.10 108.76 Seminole County GIS Value Summary Tax Amount without SOH: $1 2017 Work $E Tax Estimator Values Valuation Method ; Cost/Marke Number of Buildings 1 Depreciated Bldg Value $73,888 Depreciated EXFT Value '$461 Land Value (Market) $21,000 Land Value Ag Taxing Authority Just/Market Value " $95,349 Portability Adj Schools $67,750 $25,000 Save Our Homes Adj $27,599 'T Amendment 1 Adj � P&G Adj ----- — -- ----t $0 -- - Assessed Value $67,750 Tax Amount without SOH: $1 2016 Tax Bill Amount $E Tax Estimator FT N 76 DEG 58 MIN 42 SEC W Save Our Homes Savings: $4 Does NOT INCLUDE Non Ad Valorem Ac Legal Description LOT 4 (LESS BEG S 60 DEG 57 MIN 23 SEC W 115.064 FT OF NW COR RUN S 1 DEG 53 MIN 43 SEC W 67.833 FT W 12.392 FT N 76 DEG 58 MIN 42 SEC W 189.149 FT N 25 FT E 198.919 FT TO BEG) & BEG SW COR LOT 3 RUN N 13 DEG 20 MIN 41 SEC E 109.659 FT ELY ON CURVE 10.934 FT S 19 DEG 15 MIN 4 SEC W 105.41 FT TO BEG BLK J HIDDEN LAKE UNIT 1-C PB 17 PG 56 Taxes Taxing Authority Assessment Value Exempt Values Ta Schools $67,750 $25,000 City Sanford $67,750 $42,750 http://parceidetaii.scpafl.org/ParceiDetaillnfo.aspx?P[D=l 020305CTOJ000040 11/30/2016 12/07/2016 WED 12:52 FAX Feu; 00778.6580 Toll Frae:1.800-wlywilips Reg. a Rx1oe FL uR a SC=l; ®004/005 07 2016 MAIN OFFICE PA :.P005 Forsyth Road :WlrttprPark, Florida 32792 (407) 67B-oso0 ltlas, IntttallsHon, Show Room Order No -51f Primary Phone 374 ~ 3/fq .6 ZZJ Referred By: 107&Me1 Date 11 44-1�z_pzjySecondary Phone_ This Is a contract between Superior Aluminum Installations, Inc. and 7,071 If a rohi (theCustomeQ, who resides at 306 zrA Le.a 4,ne n1 � J c xrd , LL zip _3C773 As used In this contract, the words seller, we, us, and our refer to Superior Aluminum Installations, hie. and the words you, your and buyer refer to the Customer. Measurements and dimensions are approximate for purpose of determining price. All dimensions shown are intended to be exterior (outside) dimensions. Final dimensions are Subject to modifications to conform to standard factory fabrication, engineering, anddTYPE � d ng code.We agree to iumtsh all labor and material necessary to Install the following describe ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001-713.37, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM 1S KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUB- CONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CON- TRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER". FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THATYOU CONSULT AN ATTORNEY. FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND PAYMENT MAY BE AVAILABLE FROM THE FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND IF YOU LOSE MONEY ON A PROJECT PERFORMED UNDER THIS CONTRACT, WHERE THE LOSS RESULTS FROM SPECIFIED VIOLATIONS OF FLORIDA LAW BY A LICENSED CONTRACTOR. FOR INFORMATION ABOUTTHE RECOVERY FUND AND FILING A CLAIM, CONTACTTHE FLORIDA CONSTRUCTION INDUSTRY LICENSING BOARD AT THE FOLLOWING TELEPHONE NUMBER AND ADDRESS: Division of Professions - Oonstnrotlon Industry Licensing Board • 194D North Monroe Street. Tallahassee. FL 32399.1039, Phone: 850.487.1385 BUYER'S RIGHT TO CANCEL: Homeowner Three Day R ightTo Canoe!- 0 you do rd want the goods and/or servioss as stipulated on Otis sw ed cc, it you maycancel this agreement by malling a notice to the seller (Superior Aluminum Inslaliations, Inc.). The notice must indicate that you do not want the goods and/or services and must be postmarked before midnight of the thlyd business day after you sign this agreement. TOTAL 113 DEPOSIT WTH ORDER 1%11C� TERMS: CASH or CHECK 14 ON LAYOUT J(9jjEjjP'/ FINANCING IM ON INSTALLATION TO INSTALLER dstC� .4 �'Y�R MAAND GUARA WORKMANSHIP OUARANTEEO It after going through the normal channel of operations, you are dissatisfied or have any unresolved problems, please call and ask for me personallyat407-W-MG6 Timothy Orle, President / Superior Aluminium Installations, Inc. THE INSTALLATION WILL BE COMPLETE ON OR ABOUT W % rd (J&ICS Af'lrl 11PrA_ r7, IT 13 UNDERSTOOD BY YOU THAT THE FOLLOWING CONTINGENCIES COULD MATERIALLY CHANGE THE ESTIMATED COMPLETION DATE STATED ABOVE: CUSTOMEWS INABILITY TO OBTAIN OR QUALIFY FOR FINANCING; INCLEMENT WEATHER; STRIKES OR OTHER LABOR DISRUPTIONS; NON-AVAILABILITY OF MATERIALS; ENGINEERING: PERMITTING; ACTS OF GOD. BY SIGNING BELOW, YOU ACKNOWLEDGE TI4AT YOU OWN THE ABOVE PROPERTY AND THAT YOU AGREE TO ALLTERMS OF THIS CONTRACT. THIS CONTRACT IS SUBJECT TO FINAL APPROVAL. OF SUPERIOR ALUMINUM INSTALLATIONS, INC. MANAGEMENT AND SUPERIOR ALUMINUM INSTALLATIONS, INC. RESERVES THE RIGHT TO CANCEL THIS CONTRACT AT ANYTIME P RTO START OF WORK Q� . c Date JZI-7/rd& Ciatonar t �s)�'�',► �' 1 y C� �filW sa»s aeprauntatM . %��/'/l cusmme► - - REv ane of r Date: SEM/NOLE COUNTY MOLT/ IUR/SD/CT/ONAL LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs 11/21/16 I hereby name and appoint: Kevin Gervais an agent of: Superior Aluminum (Name of Company) to be my lawful attorney-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): ❑✓ All permits and applications submitted by this contractor. Or ❑ The specific permit and application for work located at: (Street Address) -Expiration Date for This Limited Power -of Attorney: License Holder Name: Timothy Orie State License Number: SCC056770 Signature of License Holder: STATE OF FLORIDA COUNTY OF 0'4a (A—Q 11/21/17 The foregoing instrument was acknowledged before me this 21 day of n-t)I.,� 20 16 , by TI f',0 J 0rie who isqJ• personally known to me or O who has produced and who did (did not) take an oath. Qom- � Signature of Notary Deneha Ruth Lb* NOTARY PUBLIC STATE OF FLORIDA FF937222 Expires 8124/2018 as identification T 42� billy) Print or type Notary name Notary Public - State of - ler v` Commission No. My Commission Expires: d 1 ?_zl % 1 a THIS INSTRUMJNT PREPAR�p BY: Name: 5 of + u Address oo Rd. 4/ ,.A-et NOTICE OF COMMENCEMENT Permit Number: Parcel ID Number. /O - ZO - 30 S CT - OJOb 00 q0 MARYANHE MORSEr SENIHOLE COUNTY C!_ERK OF CIRCUIT COURT & COMPTROLLER Bit 8820 Fo 124.8 (1P9,.0 CLERK'S Y 2016127276 RECORDED 12/08/2016 09:23:2 4111 RECORDING FEES $10.00 RECORDED BY hdavorz The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal 2. GENERAL DESCRIPTION OF IMPROVEMENT: of the property and street address If available) Gi fs 3. OWNER INFORMATION t OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR �E IMPROVEMENT: Name and address:l'1/�1'j ry 'Er30G Z=k f'~ Letµ. So,lbr'Ir, 9 U773 Interest in property: Ow n-ff Fee Simple Title Holder (if other than owner listed above) Name: Address: 4. CONTRACTOR: Name: SUPERIOR ALUMINUM Phone Number: 407-678-0500 Address: 3005 FORSYTH RD. WINTER PARK, FL 32792 S. SURETY (If applicable, a Address: of the payment bond is attached): Name: 6. LENDER: Name: 4 P I f Phone Number. Address: Amount of Bond: Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name'. �/ Phone Number: 8. In addition, Owner designates of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. (Signature of Owner or Lessee; or Ownels or Lessee's (Pdnt Name and protide Signatory'e T►ge=ce) Authorized Ofricer/Dtrertor/Partner/Manager) State ot`VJQ�Ida County of i The foregoing Instrument was acknowledged before me this ! day of 20 by► 6�/ IeOM-lir Who is personally known tome 0 OR Mime of person making statement who has produced identificationo4type of Identification produced: Deneha Ruth Link NOTA � T o NOTARY PUBLIC G STATE OF FLORIDA Comm#FF937222 VMRED COPY-M&ROAWWRME ?y 11b Expires 8124/2019 CLERKOGTIIR UR AND i N rnMPT nh i GD I'f O .acmnv k L A •+h��i......... Guw+ BY DEPUTY 0 8 2016 RECORD COPY lis.S.UPERIOR ALUMINUM INSTALLATIONS, INC. COVER SHEET Florida Building Code 2014 -5th Edition AAF Guide to Aluminum Construction 2010 Residential- Max Wind Speed 130 mph/ Exposure B 2015 Florida Statutes 489.113 Section 9 (b) States any structure under 1200 sq.ft. does not require an engineer's signature. For the purpose of issuing building permits, local building officials shall accept such drawings, specifications, or plans when submitted by any licensed contractor. A cu --1-I ec> , ox aS % 't>0-rf %I*,-- cA-j11ta C -Me is ?.t -Q v 'e*>p v PuLAc-c r,>,o¢.S *-j A" &k sr -1 rc -'yfRvcttlRE C4vye) 1"-113 (3) (4L) r-vFAbA 5rMM REVIEWED FOR CODE COMPLIANCE 5F PLANS EXAMINER DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE #16-3268 Guide to Aluminum Construction in High -Wind Areas ASCE7 Supplement to the 2010 Guide Published by the Aluminum Association of Florida 3165 McCrory Place, Suite 185 • Orlando, FL 32803 www.aaof.org • info@aaof.org V2010 ALLOWABLE SPANS for Primary Members N Screen Wats (Posts/Cobrnns) Wind Zone = 140 MPH Design Pressure: FOR Screen Mesh: 18/14 wo cc cr 18.5 Chapter 2 - Screen Rooms Alloy: 600575/606176 Post /Column 4'-0' lead Widths or Spaang 4'-6" 51•0" 5'•6" 6'-0" 6'-6" 7'-0" ALLOWABLE SPANS for Pririary Members In Sween Wags (Posts/Columns) 81-0' 2" X 2" X 0.046" X 0.046" Hollow 5'-3"(1) Tabes 203d 4'-8"(1) 4'-6"(1) Wind Zane = 130 MPH 3'-10'(1) Design Pressure: 15.8 PSF Exposure B a 0 6'-6"(I) FOR Screen Mesh: 18/14 5-10'(1) S -T(1) S-5"(1) 2" X 3" X 0.05" X 0.05" Snap 8'-3"(1) Mean Roof Heigh ? 30 R 0 7'-0"(1) Alloy: 600575/606176 6'-5"(1) load Width or Spacing 6'-0"(1) 5'-l0"(1) 2" X 4" X 0.050" X 0.050" Hollow 8'-11"(1) 8'-4"(1) LL 7'-T(1) Post /Column 4'-0" 9'-6" S-0' 7•6" 6'-0' 6'•6" 7'-0' 7'�i' 8'-0" O z T-9"(1) 2" X 2" X 0.096" X 0.096" Mellow 5'-8"(1) S-4"(1) S-i"(1) 4'-10"(1) 4'-T(1) 4'-5"(1) 4'-3"(1) 4'-2"(1) 4'-0"(1) 0 6'-8'(1) 2" X 3" X O.OS' X 0.05" Hollow 8'-3'(1) T-30"(1) T-5"(1) T-1"(1) 6'-9"(1) 6'-6"(1) 6'-3"(1) 6'-1"(1) 5'-10"(1) a u 2"X5"X0.05"X0.116" SMB 2" X 3" X 0.05' X 0.05" Snap 8'-11"(1) 8'-5"(1) 7-11'(1) T-7"(1) 7'-3"(1) 6'-11"(1) 6'-9"(1) 6'-6"(1) 6'-3"(1) 0 10'-5'(1) 2" X 4" X 0.050" X 0.050" Hollow 9'-T(1) 9'-0'(1) B'-T(1) 8'-2"(1) T-10"(1) 7'-6"(1) T-3'(1) 7-0'(1) 6'-9"(1) a f 2" X 4" x 0.05"X 0.05" Snap 10'-T(i) !0'-0"(1) 9'-6"(1) 9'-1"(1) 8'-8"(1) 8'-4"(1) 8'-0"(1) 7-9"(1) 7'-6"(1) z 1T-11'(2) 2" X 5" X 0.050" X 0.050" Hollow 91-11"(1) 9'-4"(1) 8'-10'(1) 8'-5"(1) 8'-1"(1) T-�3"(1) 7-6"(1) T-3"(1) 7'-0"(1) 20'-T'(2) 2"X 10"X.092"X.389" SMB 2"X4"X0.046"X0.10" SMB 8'-9"(1) 8'-3"(1) T-10"(1) T-6"(1) T•2"(1) 6'-11'(1) 6'-8"(1) 6'-5'(1) 6'-2'(1) J a W 9'-4"(1) 2"XS"X0.05"X0.116"SMB 10'-8'(1) 10'-1'(1) 9'-T(1) 9'-1'(1) 8'-9"(1) 8'-5"(1) 8'-1"(1) 7'-10"(1) 7'-7'(1) S H 11'-4"(1) 2"X6"X0.05"X0.12" SMB 10'-5'(2) 11'-3'(1) 10'-8"(1) 10'-2"(1) 9'-9"(1) 9'-4"(1) 9'-0"(]) 8'-9"(1) 8'-S'(1) O 2"X7'X0.055"X0.12'SM8 13'-3"(1) 12'-6'(1) 11'-10"(1) 11'-3'(i) 10'-10"(1) 10'-5"(1) 10'-0'(1) 9'-8"(1) 9'-4"(1) z O 2'X8X.072"X0.224" SMB 29'-8"(2) 23'-3"(2) 22'-1"(2) 21'-1"(2) 20'-2"(2) 19'-4"(2) 18'-8'(2) 18'-0'(2) 1T-S(2) Ln �_ 2"X9"X.082"X.306" SMB 31'-6"(2) 29'•8"(2) 28'-2"(2) 26'-10"(2) 25-8"(2) 24'-8"(2) 23'-10'(2) 22'-11"(2) 22'-3'(2) 2"Xl0'X.092"X.389' SMB 37-11"(2) 35-10"(Z) 33'-11'(2) 32'-5"(2) 31'-0"(2) 291-10'(2) 28'-9"(2) 2T-9"(2) 26'-10"(2) z 3" X 3" X 0.090" Hollow 10'-8'(1) 10'-1'(1) 9'-6"(1) 9'-1'(1) 8'-8"(1) 8'•4"(1) 8'•1'(1) 7-T(l) T-6"(1) rW 3" X 3" X 0.125' Hollow 14'-1"(1) 13'-6"(1) 12'-10"(1) 12'-2"(1) I1'-8"(1) 11'-3' G cc3 W x F 5 0 2 F 3. s a z s O W O x z 0 v 0 a W W m O r O z 0 0 N O 'a O AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Page 2 - 54 ALLOWABLE SPANS for Primary Members N Screen Wats (Posts/Cobrnns) Wind Zone = 140 MPH Design Pressure: FOR Screen Mesh: 18/14 wo cc cr 18.5 Table 203e PSF Exposure B Mean Root Heigh ? 30 R Alloy: 600575/606176 Post /Column 4'-0' lead Widths or Spaang 4'-6" 51•0" 5'•6" 6'-0" 6'-6" 7'-0" 7'(�' 81-0' 2" X 2" X 0.046" X 0.046" Hollow 5'-3"(1) 4'-11"(1) 4'-8"(1) 4'-6"(1) 4'-3"(1) 4'-1'(1) 3'-11"(1) 3'-10'(1) 3'-8"(1) 2" X 3" X 0.05" X 0.05" Hollow T-8"(1) 7'-3"(1) 6'-10"(1) 6'-6"(I) 6'-3'(1) 6'-0"(1) 5-10'(1) S -T(1) S-5"(1) 2" X 3" X 0.05" X 0.05" Snap 8'-3"(1) T-9"(1) 7'�"(1) 7'-0"(1) 6'-9"(1) 6'-5"(1) 6'-3"(1) 6'-0"(1) 5'-l0"(1) 2" X 4" X 0.050" X 0.050" Hollow 8'-11"(1) 8'-4"(1) 7'-11"(1) 7'-T(1) T-3"(1) 6'-11"(1) 6'-9"(1) 6'-6"(1) 2' X 4^ X 0.05" X 0.05' Snap 9'-10"(1) 9'-3"(1) 8'-10'(1) 8'-0'(1) T-9"(1) 7'-5"(1) T-2"(1) 6'-I1"(1) 2" X 5" X 0.050" x 0.050" Hollow 9'-2"(1) 8'•8"(1) 8'-3'(1) 7-10"(1) T-6'(1) T-2"(1) 6'-11'(1) 6'-8'(1) 6'-6"(1) 2"X4"X0.046"X0.10"SMB 8'-1"(1) 7'-8"(1) T-3"(1) 6'-11'(lj 6'-8'(1) 6'�"(1) 6'-2"(1) 5-11'(1) 5'-9"(1) 2"X5"X0.05"X0.116" SMB 9'-11"(1) 9'-4"(1) 8'-10"(1) 8'•5"(1) 8'-1"(1) 7'-9"(1) T-6"(1) T-3'(1) 6'-11"(1) 2"X6"X0.05"Xo.12" SMB 10'-5'(1) 9'-11"(1) 9'-S(1) 9'-0"(1) 6'-8"(1) 8'�"(1) 8'-1"(1) r-10"(1) 2"X7'X0.055"X0.12" SMB 12'-3"(1) 11'-T(1) LO' -0"(1) 9'-T'(1) 9'-3"(1) 8'-11"(2) 8'-8'(2) 2'7(8X.072"X0.224'SMB 22'-10"(2) 21'-7"(2) 20'•5'(2) 19'-6"(2) I8'-8"(2) 1T-11'(2) 17'-3"(2) 16'-8"(2) 16'-2"(2) 2")(9"X.082"X.306" SMB 29'-2"(Z) 2T-6'(2) 26'-1"(2) 24'-10"(2) 23'-10"(2) 22'-10'(2) 22'-0"(2) 21'-3"(2) 20'-T'(2) 2"X 10"X.092"X.389" SMB 35'-2"(2) 33'-2'(2) 31'-5"(2) 29'-11"(2) 28'-9"(2) 2T-7"(2) 26'-T(2) 25-8"(2) 24'-10"(2) 3" X 3" X 0.090" Hollow 9'-10"(1) 9'-4"(1) B'-10"(1) 8'•5"(1) 8'-1"(1) 7'-9"(1) 7'-5"(1) T -2'(I) 6'-I1"(1) 3" X 3" X 0.125' Hollow 13'-3"(1) 12'-6'(1) 11'-10"(1) 11'-4"(1) (1) 10'-5'(2) 10'-5"(2) ld-1"(2) ALLOWABLE SPANS for Primary Members N Screen Wats (Posts/Cobrnns) Wind Zone = 140 MPH Design Pressure: FOR Screen Mesh: 18/14 wo cc cr 18.5 Table 203e PSF Exposure B Mean Root Heigh ? 30 R Alloy: 600575/606176 Post /Column 4'-0' lead Widths or Spaang 4'-6" 51•0" 5'•6" 6'-0" 6'-6" 7'-0" 7'(�' 81-0' 2" X 2" X 0.046" X 0.046" Hollow 5'-3"(1) 4'-11"(1) 4'-8"(1) 4'-6"(1) 4'-3"(1) 4'-1'(1) 3'-11"(1) 3'-10'(1) 3'-8"(1) 2" X 3" X 0.05" X 0.05" Hollow T-8"(1) 7'-3"(1) 6'-10"(1) 6'-6"(I) 6'-3'(1) 6'-0"(1) 5-10'(1) S -T(1) S-5"(1) 2" X 3" X 0.05" X 0.05" Snap 8'-3"(1) T-9"(1) 7'�"(1) 7'-0"(1) 6'-9"(1) 6'-5"(1) 6'-3"(1) 6'-0"(1) 5'-l0"(1) 2" X 4" X 0.050" X 0.050" Hollow 8'-11"(1) 8'-4"(1) 7'-11"(1) 7'-T(1) T-3"(1) 6'-11"(1) 6'-9"(1) 6'-6"(1) 2' X 4^ X 0.05" X 0.05' Snap 9'-10"(1) 9'-3"(1) 8'-10'(1) 8'-0'(1) T-9"(1) 7'-5"(1) T-2"(1) 6'-I1"(1) 2" X 5" X 0.050" x 0.050" Hollow 9'-2"(1) 8'•8"(1) 8'-3'(1) 7-10"(1) T-6'(1) T-2"(1) 6'-11'(1) 6'-8'(1) 6'-6"(1) 2"X4"X0.046"X0.10"SMB 8'-1"(1) 7'-8"(1) T-3"(1) 6'-11'(lj 6'-8'(1) 6'�"(1) 6'-2"(1) 5-11'(1) 5'-9"(1) 2"X5"X0.05"X0.116" SMB 9'-11"(1) 9'-4"(1) 8'-10"(1) 8'•5"(1) 8'-1"(1) 7'-9"(1) T-6"(1) T-3'(1) 6'-11"(1) 2"X6"X0.05"Xo.12" SMB 10'-5'(1) 9'-11"(1) 9'-S(1) 9'-0"(1) 6'-8"(1) 8'�"(1) 8'-1"(1) r-10"(1) 2"X7'X0.055"X0.12" SMB 12'-3"(1) 11'-T(1) LO' -0"(1) 9'-T'(1) 9'-3"(1) 8'-11"(2) 8'-8'(2) 2'7(8X.072"X0.224'SMB 22'-10"(2) 21'-7"(2) 20'•5'(2) 19'-6"(2) I8'-8"(2) 1T-11'(2) 17'-3"(2) 16'-8"(2) 16'-2"(2) 2")(9"X.082"X.306" SMB 29'-2"(Z) 2T-6'(2) 26'-1"(2) 24'-10"(2) 23'-10"(2) 22'-10'(2) 22'-0"(2) 21'-3"(2) 20'-T'(2) 2"X 10"X.092"X.389" SMB 35'-2"(2) 33'-2'(2) 31'-5"(2) 29'-11"(2) 28'-9"(2) 2T-7"(2) 26'-T(2) 25-8"(2) 24'-10"(2) 3" X 3" X 0.090" Hollow 9'-10"(1) 9'-4"(1) B'-10"(1) 8'•5"(1) 8'-1"(1) 7'-9"(1) 7'-5"(1) T -2'(I) 6'-I1"(1) 3" X 3" X 0.125' Hollow 13'-3"(1) 12'-6'(1) 11'-10"(1) 11'-4"(1) 10'-10"(1) 10'-5'(2) 30'-0"(2) 9'-8"(2) 9'-4'(2) Chapter 2 - Screen Rooms X 2" OB @ PERIMETER z N #1 : USE 'LONG LAG SCREWS INTO g W HOST AND '/ 0 X 2�/a" LONG CONCRETE SCREWS INTO NCRETE R MASONRY CONSTRUCTION W (1" EMB ME TYPICAL) SPACING 24" O.C. AND WITHIN °C 6" OF EA RPENDICULAR MEMBER 1" X 1" /16" GLES 2" LONG WITH 2-#8 X 1/2" LONG N S.M.S T EACH TYPICAL EACH SIDE, TOP &BOTTOM) O HOST STRUCTURE EyE CONNECTION WITH EXPOSED FASTENERS 1" X 2" OB @ PERIMETER \ Z REFER TO NOTE #1 - THIS SHEET 2- # 10 S.M.S. FROM INSIDE FACE OF Lu 1 X 2 OB INTO SCREW SPLINES OF 1 X 2 US cc OB (I" EMBEDMENT MINIMUM.) a�C REFER TO NOTE #1 - THIS SHEET tnN O HOST -STRUCTURE ELEMENTS ' CONNECTION WITH CONCEALED FASTENERS PARTIAL ELEVATIONS / 1" X 2" TO 1" X 2" CONNECTIONS '�_l 2 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 0 Chapter 2 - Screen Rooms 1 X 2 OB @ PERIMETER 1 X B@ PERIMETER FASTEN PER NOTE #1 \ N PER NOTE #1 _2" " HOLLOW %RECOWNGXCHANNEL 1 \ 1" X 1" /8" ANGLES ( OF GIRT DEPTH S 1/2") WITH POST / 2- #8 X 1/2" LONG S.M.S. AT EACH LEG. (TYPICAL TOP & BOTTOM) CONNECTION W/ EXPOSED FASTENERS 1 X 2 OB @ PERIMETER FASTEN PER NOTE #I GIRT (DETERMINED BY TABLE) NOTE #1 : USE 1/4"0 X 3" LONG LAG SCR"S INTO WOOD HOST AND 1/e"0 X 2'/0" LONG ON SCREWS INTO CONCRETE OR MASONRY CONSTRUCTION (1" EMBEDMENT TYPICAL) SPACING 24" O.C. AND WITHIN 6" OF EACH PERPENDICULAR MEMBER 12- # 10 S.M.S. FROM INSIDE FACE OF 1 X 2 08 INTO SCREW SPLINES OF HOLLOW GIRT (1" EMBEDMENT T MINIMUM.) CONNECTION W/CONCEALED FASTENERS PARTIAL ELEVATIONS / 2 X 2 GIRT TO 1 X 2 CONNECTIONS AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 2 1" x 1" x 1/e 2" LONG wr S.M.S. AT EP (TYPICAL EA Chapter 2 - Screen Rooms CONNECTION W/ EXPOSED FASTENERS 4 - # 10 S.M.S. FROM INSIDE FACE OF POST INTO SCREW SPLINES OF HOLLOW GIRT (1-1/2" EMBEDMENT MINIMUM) — GIRT OR CHAIR RAIL SELF MATING POST CONNECTION W/ CONCEALED FASTENERS GIRT TO POST CONNECT-IGN ` f C5 2 Page 2 - 15 1 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 2 - Screen Rooms ROOF PANELS (SELECT PER TABLE 201) %moi i � � � �i �� � i� i i� i♦ I 0 X t S.M.S.O S.M.S. INTO 2" X 2" X.046"J SCREW BOSSES CONTINUOUS HOLLOW POST HOLLOW POSTS W/ 2" X 2" HEADER ROOF PAN (� PER TABLE 201) a a s e a s m a e e ®c s s o s a a (4)-# 10 X 4" 2" X 2" X.046" S.M.S. INTO SCREW BOSSES SELF -MATING POST 2X2 POSTS TO SIDE WALL HEADER CONNECTION C6 (PARTIAL ELEVATIONS @ WALL FACE) 2 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 Chapter 2 - Screen Rooms 4 EACH # 12 SMS 5/8.0 20 GAUGE STEEL WASHE VANIZED OR 304 STAINLESS)0/ BONDED SELF-SEALINGe- MAMWOR APPROVED EQUIVALENT) PER ROAM 3" RISER ROOF PANEL (SELECT FROM TABLE 201) BEAM / SECTION ROOF PANEL FASTENING DETAIL #1 C2 (3" RISER PANELS) 2 1/4" 0 THRU BOLT W/ I -pr- 1,1L�IA 0 10" O.C. (TYPICAL) - 3/8" 0 BOL REQ'D FOR 6" THICK ROOF PANELS C 77 C)0 go cr , , C O l0 — v — CONTINUOUS ANGLE 2" X 2" X 1/8" FOR EDGE BEAMS FOR INTERMEDIATE BEAMS 2" X 2" X 3/16" THICK W/ #14 SMS 0 6" O.C. (TYPICAL) COMPOSITE ROOF PANEL (SELECT FROM TABLE 201) NOTE. THE 2"X2-XI/8" CONTINUOUS ANGLE MAY BEAM SELECTED FROM TABLE BE ELIMINATED BY BOLTING THE COMPOSITE 202 (MAY BE HOLLOW OR PANELS THRU THE SUPPORTING BEAM SELF-MATING/LAP EXTRUSION SECTION ROOF PANEL FASTENING DETAIL #2 C2 (COMPOSITE PANELS) 2 AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 PaS Chapter 2 - Screen Rooms COMPOSITE ROOF PANEL (REFER TO TABLE 201) RECEIVING CHANNEL WITH #14 X 3/4" S.M.S. @ 10" O.C. TOP AND BOTTOM J w r.,0 0v FASTEN TO FASCIA WITH 1/."0 X ZIA" LAGS 12" ON CENTER ALONG HEADER NOTE: FASCIA MU ' NOMINAL, 1" NOMINAL FASCIA MAY B AUGMENTED TO 2". COMPOSITE ROOF PANEL CONNECTION TO HOST FASCIA EXISTING FASCIA # 14 SMS 10" ON CENT THRU RECEIVING CHA INTO PANEL TOP AND r� WALL 0 rJ AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 u- 0 O a Z • EXISTING MASONRY • OR WOOD FRAMED a ' HOST STRUCTURE _ PERIMETER WALL ~ ' f CL z 3 W S H F WHERE PROXIMITY OF HOST EAVE PROHIBITS o~c INSTALLATION OF FASTENER INTO TOP OF PANEL, a FASTEN PANELS @ BOTTOM W/ 6 EACH #14 SMS PER PANEL (THIS APPLIES ONLY TO MAXIMUM p ROOF PANEL SPAN OF 12' AND A ROOF HEIGHT J OF 8', ALL OTHER APPLICATIONS REQUIRE SITE _ SPECIFIC ENGINEERING) 3 z_ c EXISTING MASONRY OR W WOOD FRAMED HOST a STRUCTURE PERIMETER WALL a uj EXTRUDED OR MINIMUM .040 THICKNESS of ROOF HEADER (A.ICA. RECEIVING CHANNEL) WITH 1/4"0 X 21h" LONG LAG SCREWS FOR z LUMBER MOST 1 PER STUD - 3/8'V X 2'h" LONG MASONRY SCREWS FOR MASONRY N HOST @ 16" O.C.cc _ c� a rJ AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 PRODUCT APPROVAL COVER SHEET CUSTOMER NAME: eer-of+l CUSTOMER ADDRESS: �O(, Loc,l, (-0,„,) MANUFACTURER PRODUCT APPROVAL NUMBER 6 1► �e, /Zoop- FL 75-61 R -3 Florida Building Code Online C Cd:Waaraq � eCIS Home Log In . user Repbtration not Topa : suomd su�arye ' suits a FaW Busines cilt Approval 0USM: PUN Professional USM: PUNIC Wer Regulation ® F,ee,it •eererY Meng > rYeaua a •oeiau•n Scan:n > Aooiranon Liu > AppnolMon 0WWI FL # FL7561-R3 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Page 1 of 2 =WE /J Pu01Katlare : Fec SUIT � OC1S Sire Mao ' Unks : sm" Product Manufacturer Site Aluminum Corporation Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954) 949-3200 dk@dolomengsneering.net Auttiorized Signature Do Kim d kodokimengineering. net Technical Representative Dan Cooke Address/Phone/Emaid 1801 NW 64th Street Ft. Lauderdale, FL 33309 (954)491-3700 elitealum0aol.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Introduce0 as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flonda Professional Engineer ✓. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Do Kim, P.E. PE -49497 Quality Auditing -Institute Ltd. 11/30/2020 James L. Buckner, P.E. at CBUCK Engineering Validation Checklist - Hardcopy Received 1709.2 http://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgsgJkzX72BeuCe... 7/9/2015 Florida Building Code Online Product Approval method Method 2 Option B Date Submitted 04/30/2015 Date Validated 05/01/2015 Date Pending FBC Approval 05/10/2015 Date Approved 06/23/2015 Summary of products r Page 2 of 2 FLA I Model, Number or Name Description 7561.1 Aluminum/Aluminum Composite 3"/4"/6"x0.024"x1lb EPS Composite Panel, Panels 3"/4"/6"x0.032x1lb EPS Composite Panel, 3"/4"/6"x0.024`x2lb EPS Composite Panel, 3"/4'/6"x0.030"x2lb EPS Composite Panel, Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL7S61 R3 Il EIRP FL7S61-R3 2014 FBC Installation Approved for use outside MVMZ: Yes Dwo.odf Impact Resistant: No Verified By: Do Kim, P.E. PE 49497 Design Pressure: +80/-80 Created by Independent Third Party: Yes Other: In HVHZ, not to be used In structures considered Evaluation Reports living areas per FBC Section 1616 unless impact protection FUS61 R3 AE Elite Alum FL7561-R3 2014 FBC is provided. See installation drawing for nominal allowable Evaluatlon.odf design pressures and spans. Created by Independent Third Party Yes ONest contact Us: - 19N Hart" Monroe Street. 7alhnesXe FL 32399 Phone: 850.467-1824 The State of Flora& d on AA/EEO emp"r, toovMht 2007.2013 Stale M Florida... Pnvacy Statement :: Access.oditV State,"rrc :: Rcnrnd Slatement tinter Flondo law, even addresses are pudic records If you do not went vow e -recoil address reteased In response to a puWK-reWfdS reauest. Uo not Send efeClrolrrc mad to this thirty. instead, contact the write by phone or by traditional mall. It you hive any due;Wns, please contact 650 057.1395. •owsWnt to Section 4552751 1). Florida Statutes. effective October 1, 202, IKensm licensed under Chapter 455, G.S. nwst provide Me Department w Ur an enwd address if they nave one he !marls provided may be used for of al commun Ouon wrtn the licensee. However enact addresses are DUDIK record. U you do not wish to supply a personal address, Oaks* provide Ne Deparlirent wrtr. an entai address which can be matle available W the public. To detennure it you are a licensee under Chapter 455. F.S., PIe4Se Ord hire . Product Approval Accepts: ®®EEM credit! eAFE http://%krww.tloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgsgJkzX72BeuCe... 7/9/2015 DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS Florida Board of Engineers Certificate of Authorization No. 26887 Product Evaluation Report Date: April 10, 2015 Report No.: FL# 7561-R3 Product Category: Roofing Product sub -category: Products introduced as a Result of New Technology Product Name: EPS Foam Core w/ Aluminum Skin Composite Panels Manufacturer: Elite Aluminum Corporation 4650 Lyons Technology Parkway Coconut Creek, FL 33073 Phone: 800-421-0682 Scope: This product evaluation report issued by Do Kim and Associates, LLC and Do Kim, P.E. for Elite Aluminum Corporation is based on Florida Department of Business and Professional Regulation Rule 61G20-3, Method (2) (b) of the State of Florida Product Approval. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or updates. Do Kim and Associates, LLC and Do Kim, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Florida Building Code, 5d' Edition (FBC) and where pressure and deflection requirements, as determined by Chapter 16 of the Florida Building Code, do not exceed the design pressures as shown on the approval. 00 �GE7igt,/'j1 � o.a 9 � E O� Al L 4-25-15 Do Kim, P.E. FL #49497 P.O. Box 10039 813.857-9955 Tampa. FL 33679 dk@dokimengineering.net Sheet I of 3 DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS Supporting Documents I. Code Compliance a. The product assembly described herein has demonstrated compliance with the Florida Building Code 5d' Edition (FBC), Section 1709.2. 2. Drawings: a. Drawing No. FL -1001 titled " EPS Foam Core Composite Panels", sheet 1-1, prepared by Do Kim and Associates, LLC., signed and sealed by Do Kim, P.E. 3. Testing a. Testing per ASTM E72-05 as performed by Hurricane Engineering & Testing, Inc. (HETI), and reported in test report numbers HETI-05-1988, HETI-06-2104, HETI-06- 2066, HETI-06-2105, HETI-06-2067, HETI-05-1002, HETT-06-2107, NETT -05-1987, HETI-06-2069. HETI-06-2070, HETI-06-2071, HETI-05-1994, HETI-05-1991, HETI- 06-2072, HETI-06-2073, HETI-06-2074, HETI-05-1996, HETI-05-1989, HETI-05-1993, HETT-05-1985, HETI-05-1995, HETI-05-1990, HETI-05-1997, HETI-05-2037, HETI- 05-2029, HETI-05-2039, HETI-05-2030, HETI-05-2041, HETI-05-2048, HETI-05-2036, HETI-05-203 1, HETI-05-2038, HETI-05-2065, HETI-05-2040, HETI-05-2042. 4. Calculations a. Panel performance engineering analysis for tested loading conditions have been prepared based on comparative and/or rational analysis, prepared, and submitted by Do Kim, P.E. 5. Other a. Quality Assurance Agreement verified with Quality Auditing -Institute, LTD. (QAI Laboratories, LTD.) (FBC Organization #QUA7628). P.O. Box 10039 813.857-9955 Tampa, FL 33679 dk@dokimengineering.net Sheet 2 of 3 DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS Limitations and Condition of Use I. Code Compliance a. The product assembly described herein has demonstrated compliance with the Florida Building Code 5" Edition (FBC), Section 1709.2. 2. Large and small missile impact resistance has NOT been tested to or evaluated for in this approval. In HVHZ, this product shall be used in structures "not to be considered living areas" per Section 1616 unless impact resistance in accordance to the HVHZ requirements are met. 3. Each product listed above shall be installed in strict compliance with its respective Product Evaluation Document and site specific engineering along with all components noted herein. 4. Use of each product shall be in strict accordance with its Product Approval Evaluation and Limitations of Use. 5. Composite panels shall be constructed using type 3003-H 154 aluminum facings, 1 or 2 PCF ASTM C-578 carpenter brand EPS adhere to aluminum facings with Ashland Chemical 2020D ISO grip. Fabrication to be by Elite panel products only in accordance with approved fabrication methods. 6. Elite roof panels maintain a UL 1715 (int) class 'B' (ext) rating and are NER-501 approved. 7. This specification has been designed and shall be fabricated in accordance with the requirements of the FBC, composite panels comply with Chapter 7 Section 720, Chapter 8 Section 803, Class A interior finish, and Chapter 26 Section 2603. All local building code amendments shall be adhered to as required. 8. The designer shall determine by accepted engineering practice the allowable loads for site specific load conditions (including load combinations) using the data from the allowable loads tables and spans in this approval. 9. Deflection limits and allowable spans have been listed to meet FBC including the HVHZ (L/80 for spans < 12'-0" and L/I 80 for spans > 12'-0"). 10. All supporting host structures shall be designed to resist all superimposed loads. 11. All components which are permanently installed shall be protected against contusion, contamination, and other such damage. 12. Size and Span Limitations: a. Composite panels shall be limited to those specific panels listed in the DWG. FL -1001. b. Allowable panel spans shall not exceed those listed in the tables of DWG. FL -1001. P.O. Box 10039 813.857-9955 Tampa, FL 33679 dk@dokimengineering.net Sheet 3 of 3 ELITE PANEL SPAN TABLES 3' x OW4 a I LI) LT'S I'ANt,LS (ALL11YARI i N EAR SPAN CHARTS) rn I At LL V4 LUAU (PS. I' MAX. ALLOWABI C VAN (F h L/Av L. la^0 /140 L/240 /if0 1 -Tiff- 1 --,MdL i6 1T iF•w- _ R- NII _T"_ -t - -P r - ii ii 1 T 0'ST-%37--,M;-.] 'OJO -WIC- VOR -� 1.0 PMtL IWI•n I NiN AIPII 1 �Z•1 His MIN 1s?� na N 036 io• Y• ►� l N M 3-7-01 - •]I 4' x 0,030 x P - 13 F'S ?ANFLS (AI I 11WARl C CLLPR SPAN CILAP-S) Kit AL1 UWABLI IIIAD (P:F>I/80 p ]) N1', NAl ALLIIWAULE SPAi4 (FT) ALI GWAFLE _ LOAD (PSI )' JOD I./IPO L/180 L,1240 ii-'Fii tl.f rla av TIT '7521 4' >- 0 02 ( 1 1 R FPS PANELS (ALLOWABLL CUM' SPAN CH=,RIS) NI" AI.LOVABLC WIND tl>SF1' IIA), ALLOWABI E SPAN (r "> LL%00 L/120 1./100 L/210 N Iva 0-r171 izzr- N"', wln a 1110 la" 1 It. 1-r37- 11 n � „ L/00 1_/WO L/!00 N 'SSI a a -05w- 10 -Fin M n war ---rep- 632 ]L ��� "F7T" -re N 1 ) -wn- 6• x 0024 >, I - I R -P;: PANCLS (At 111WARI 1_ (:1 LAP CPAN CIIAV I S) NU At . Da A°I_C LUAU (PSI 0 MAX. ALLOVABLE SAA;! (rt) V80 LA20 V100 L/240 IlY CIAr N 1101 -NN- -ti'r �t - 110. -17 •_ q NI1 1 Il �1� NI o- I�e� Il.1T 15" !A Ti-ti 11r_ M- Il0 u� ali uu T.i N NIo w •: In T.f 1 Net ollowoble loods ore permitted to be multiplied by 1.67 to derive ullimote Iuods (PS0. 3' x GOP4 x 2 LI) EPS PANELS (AI_LUWAULL LLLAR SPAN CFARtS) NI I ALLUVABLI LUAD WSI)1 NAY ALLOWABLE SPAN (F 7) /if0 _ V1L'L/10It Vi•40 -11- - --,MdL i6 1T iF•w- _ R- NII _T"_ -t - -P r - TOY• 1 T 0'ST-%37--,M;-.] 'OJO -WIC- VOR -� 1.0 PMtL IWI•n I NiN AIPII 1 �Z•1 His MIN 1s?� na N 036 io• !• 1131 111 -r6-r N M Mr--Tii .• 4' x 0,030 x P - 13 F'S ?ANFLS (AI I 11WARl C CLLPR SPAN CILAP-S) Kit AL1 UWABLI IIIAD (P:F>I/80 MAt ALIIIVABIt 1PA4 (1'h 4' x C.0?4 a c - L3 CPS PANELS (ALLUWAULL CLEAR SPAN CHAR'S) N1', NAl ALLIIWAULE SPAi4 (FT) ALI GWAFLE _ LOAD (PSI )' JOD I./IPO L/180 L,1240 ii-'Fii tl.f rla av TIT '7521 i]Ti ] -70T- tom 1615 N a 1036 Iia _ t• IN 11 N'!1Aa N"', 11 N -RJ- �-1�)T 1-r37- - 6' x :1024 a i.' - I. R EFS PANEL-. (ALLOWABLE CLEAR SPAN CHARTS) NET A1.I.L'WA'ILI LOAD (PSIP MAX, ALLCWADLE SPAN (r i> L/00 1_/WO L/!00 L/240 N 'SSI a a -05w- 10 -Fin TF '' iT5- "F7T" -re N 1 ) -wn- _ TIJ) -W.-0 so IlY CIAr N 1101 fA -ti'r �t - 110. -17 •_ 1 l 1] 1 1 �=f o- I�e� Il.1T 15" GI•NI Nnl N!}Il ) 1 t.nnpu,Acl;.u,cl. >h411 he:wtNuxw+l u>inB .)PI LTU) -11151 Ahnmm�m lm�ing+.l•n!W.I r\Jta)l'-Si6:n,l•nAc, Ur nlJ l.l'S ahnnnmut I,nuy; .. •Ih .,>MJrM1; C i1 nu, JI ?U 1UI) 1\I : g„ P ; obi........ Irl Ir; Ir, I: hl, )urlrl Pr r•rlucl. uNh' i4 -.n.vnd.mu• • 11- qur :rJ I:,hNr Ilia, un•rIM1,J, _ _ - _ ? Ihla u•u!panr l.uanm]mJ1!1 1)15(in'1t41,'ll'I, ul,uuntur+l a,r NLR'•111•yPnnrI 1!m .l:rubr.mrm IL,> hea n Ja.numd .nvl Jell It, Inhlir ,Irrl III .wa.e.6Aw: r.Illr Ir\. laynr,IvnC„U M II\! I Irv,JJ 11„115,50 I'..de I Aibm, (lttf /. ,+ay\nnr lelnrl. r•runpl/ ,u,h l h.gau T 4a Dun 7211 ('h.y w, 4 i.litm W 1 0,,: A hnnirn hul>h mol C ha!ua, !Ir %"..". •Ltl Irw4l ,nnLlu,!• aNJa• Jn,G41mr Itis OIJ: ,c,A1hrw.1 In J>,ryunnl J Ilh• c'ut lr, .nJN Jrlrl w„\'))' Mra'!:IaA ti,IVlr,h'I N,It In mDrr the JI,IN,•INr Ilr:,th In, ,w •I'la,:h 1N,n1 L'm•fil,rr,,, („Ir'IIM1I,Ir� N.nl rwnMlunmmnwlrt Oa .I,rJ It'I Thr nlim•Jhlr local, mbla'A :md yr.u,+ m Jn+J!:!notyl + lkllwl.rlt Ionil. J el allnr Jhlr :n,nu Cool 1•ren hd>d to nlrrl l ll( +nahnlinY 1ha I R'll% In I I!'ll/, 11•it punlue •Tull!:r u,td Ur:IR 9URn•+Im n•Iv...... weJ IN'lllh.11 a'Jy P:, Yrrllun IAIh WILY. ImPLI Ia.Mlanr in da':rnrL„M 1u Il:r NYII/. n'hl•I/r,ln'llll .ur IIKI h, Jnlcla L:a uu •rl :.11121, br.n n>c :u .1,,rlop DIIN„aU4 hank mil ymn,. Ito !"I It." 4ltrn d.rnar hr Ibr liu:Nrhres hrf All, I— t Urualmr, l'nrl I .e\I .unhA w.: , Iln• I IIL l h.qN:r Ill 0 !N 101 V. INA, 111 .1 III -OM 10 1—111IJwhr IV AS 1 M I.12 Itx *it, coylh 1 nl l' .0, LA IN.0ti lg t,mw> hon B Itel, w•nu• 1-1 lq­" I III I Wd-1969, 111.11 UA•! IUJ, III I I•UO•?Olr,, 111• I' (Ih 211A. 10 1114• :90. 111 I I.0- Ina?, 111.1 I ur. . 1 ). I11.11•V. Ia.v7.111,1 I Illl,III.IIi I J. I II:I I . ) I, 111-1 , IF• 11•IN. it. I1.111.11 ui,•!U1J III: 11.05.11,96 611:11.45• WN9 111:1111) • IV)). III 11.0-1'!95. 111' 11 ni• 1'P)i, iii. 11.91.• 1')•41.1 it. I I-,1;, I•141 IWIf oil !D, i, IIt 1111` !P!4.111•I!•9]•:U I,r, 111 1111) 'N Ill, III II W.N 11 Iit. 1I U, !IMF 111.11 45.14)2 ilbll•US•;U)1, 11111.05 Ok 111.11-W-1flni, Ill I'1•ni.?4Ju-111.11.115.!01) '1 1.41.:11 imagY44nun>h111 M• nllu„ul iw liym: s o ilhm 1h, •ol•las >Anuu. In. I'w1;l.r, ilh Anlaana,hJp la•awl>ulnaJ_grN, Jlcw nr NnlJ,n 1•,nnl>., Wham r:n, !a•u,)1 Ur,ryn y,olto •ion:Js ma) ,:rluJ.� d---- .,1• of the U. h.:uu In 1.a.e1J JOn111 Ill'U.11 a nNl 111 .01 1-6L lheN litre 3' : 0.030 x 2 LG FPS 11AN't S (AI_LUWARLE CLEAR SFJAW CNAVS) NCI 4LUVABLE LOAD (PS;)' r1AY. ALLOWABLE SPAN VT) L/90 L/120 1./180 1_/2t0 -11- iiT1- -go -Mi£' -Tfir 10 -%7W- -i 1 -1522- -Tf - I• 0'ST-%37--,M;-.] L UPL P,YI Wlalll 011f0.1iK, -� ii •T1 1 -,%w- PMtL IWI•n I NiN AIPII 1 �Z•1 His MIN 1s?� na N 036 io• YY W-4 I.IJ �IrO� N M 4' x 0,030 x P - 13 F'S ?ANFLS (AI I 11WARl C CLLPR SPAN CILAP-S) Kit AL1 UWABLI IIIAD (P:F>I/80 MAt ALIIIVABIt 1PA4 (1'h ' Ill L 1^0 II L/100 Coll L4,'46I t.l! s TIT '7521 i]Ti / q OI AM 0111[4 C1411KCa P4y1SPAN•(It• PA11 AI tI DI 11 EPS ROOF PANEU SPAN DESCRIPTION H 4 JN )1 N'!1Aa 11 N -RJ- �-1�)T 1-r37- - IOSJ- ,.W- 6' x OC30 / 2 - LB FPS PANELC (RL_I1t+TAlh L Cl EAR SPL•,N CHARTS) UAL NCi ALLUWABLC LIIAU (P:F)' N MA), ALLOVADLC SPA11 (1'-) / 10 . /1') •' LT•01 ' /100 � L/240 000(0 1OOGOOC� Li )0002 00000( I111Lft"1®AM1.UcI= 1PNWM L UPL P,YI Wlalll 011f0.1iK, AIV CU NIP C PMtL IWI•n I NiN AIPII 1f d O O O O O f]joy �O�C�C�C�G� II'1 rWF R0 (P Af 0000000 *00• %] i 1 -951­75111b- .1 f N M f -llLA4 1PIN h) rNSlff '11 IASIOC -1A61.rf(t iill All n 1 0! _ b Ir���OI LINe•I,rC 95455 O> Jal opt OtnL);rPMFL WIe1N • SIX, q DO KIM O OSODUTAIL7. LLL' CONSULTING STRUCTURAL ENUINEERS rA GI• ,p,:9 •,moon r•Lm n. lots as* rose /'rl n• 'IsnnV "n1•anPrn' raw /4 a :•iiiL�nA'nwu � s ILa4worr,ore.er, 1u1R0Pr C� P \c O 1O AR 1'. c� •2518 DfemngNo. -FL-1001 ShEF.I 'OF 1 AAL AUI91 WI IN CONIIAUIIIl CAIA41•b 000(0 1OOGOOC� Li )0002 00000( I111Lft"1®AM1.UcI= 1PNWM L UPL P,YI Wlalll 011f0.1iK, AIV CU NIP C PMtL IWI•n I NiN AIPII 1f d O O O O O f]joy �O�C�C�C�G� II'1 rWF R0 (P Af 0000000 *00• i N WtNelo I COIDI. f -llLA4 1PIN h) rNSlff '11 IASIOC -1A61.rf(t U,0 J RLL]PtD to 1'N;v11r ICA .Ow' !finnfCIONS 1. A•0 IVICIL•uyll C 21Y.LiK/MT1••4 LINe•I,rC 95455 O> Jal opt OtnL);rPMFL WIe1N • SIX, OI AM 0111[4 C1411KCa P4y1SPAN•(It• PA11 AI tI DI 11 EPS ROOF PANEU SPAN DESCRIPTION DO KIM O OSODUTAIL7. LLL' CONSULTING STRUCTURAL ENUINEERS rA GI• ,p,:9 •,moon r•Lm n. lots as* rose /'rl n• 'IsnnV "n1•anPrn' raw /4 a :•iiiL�nA'nwu � s ILa4worr,ore.er, 1u1R0Pr C� P \c O 1O AR 1'. c� •2518 DfemngNo. -FL-1001 ShEF.I 'OF 1 rr�;��' PLAT OF SURVEY- "-` CA ROLE J. GE-RRE TT 460'> 11` DESCRIPTION = ` ' TE'PTe A portion of LOT 1, SE= J, BIDOM XApm UNIT 1-C, as r000rded in plat Sock 17, pages SS and 56, of the public Records of Ssalnols County, Florida; described as follows# Beginning at the Southwest corner of said LOr 1, rum M 11020111' t along the West lot line of said LOT 3, a distance of 109.659 feet to the Northwest corner of said LOT 1, said Corner being on a curve concave Northarly, and having a radius of 50.00 foots thence from a tangent bearing of 9 76019.19' If run sastorly•alonq the aro of said curve 10.934 toot through a central angle of 12°11117's thaws rum S 19015101' W 105.11 test to the point of beginning, NID LOT 1, 81= J, SIDD= LAZZ UNIT 1-C as recorded is plat Book 17, pages SS and 56 of the Public boords of Seminole County, Florida, loss faros the Northwest corner of said LOT 1, said point also being on the Soutbwestarly right-of-way of Loch Low Lane, run S 60°57127' W along the Northwesterly property line of said LOT 1, 113.061 toot to the point of beginnings thence run S 01051111' W 67.511 test to a point on this South line of said Xor 6, said point being 111.096 feet ff 59011106.5' W fr= the Southeast corner of said LOT 1, thance sus N 59011.06.5• W along said South line of wr 1, 12.192 feet, thence run H 760S8'12' W along the Southwastarly line of said Lor 1, 159.119 foot, thence run North along the Westarly line Of said LOT d, 25.00 feat, thence rum But 195.919 feet to the point of bsglan' S. APPRO X- WATER EDC•�F /O-3/-69 p�N - 8 L OW ( /39.Op's EAST / 9B 9/9 P. lr L ^ W NORTH 2S.00 j 00-f SWAGGERTY LAND SURVEYING 9 INC. 3550 S.R. 46 W. SANFORD, FLORIDA 32771 4107) 322-4630 Ok to install screen room with concrete as shown on plan. Meets area and dimension regulations for SR -1A zoning district. l� 1 I a`✓� � P 5 1� 4 / I � i GONG. PATIO � '6aSB,¢Z'1 ` � <99 T'lilS NO'f L!Z J�'?'NO ?jqREc. r P ESTABUSPED 100 Yc.A.R FLOW PRONE AREA. G,eEE.v FL000 Lo.vE "C . �ERTiF/EO CORRECT 727 : KiFMPF T�rGE c v eol� ✓. o��t eErr GA[/FO�C•v/i7 FEOERNL S•iV�•t�GS �Loq.V �7530G. M COAC COPC. WALK r*' ffoa�e' / (p -5o&) NE LOCH LOw l"A t� Oar !� a<,r�rsr t=�ovX'a=��a 051 TKSP> — Ag1frO1 LOT9 N. l3°20'¢1 E. 109.65q(PLAT) 103.660 CMEAS.) L,n W * o S 19°1504_ W. 105 41' �% 4 .. a h C441 14 4 W rfAKC CrYv> s s' i r WIRE FeACE ri P.� % PO. 8 vAL sMr CSW. co a cony) N. ego//'06.5 W. l3 ELT aro x---4 HERESY CERT IF- ?HAT THE SuRYEY SHOWN HEREON WAS MADC OM ACC 1RDANCE TO THE iIINIYUN 'iSNOI K L STAIC-C.`W FOR LAND DATE OF: SURVEYM: IN TN[ STAT: OF FLORIDA !H Ill OIl .IND CH. 1 : HI'. -5 I.A.C. eoUNDARY CERT:FIEG CORRE.. ' FOUND 10-31-88 FINAL REG. LAND SURVEYOR. NO. 376¢ SEC--L0-,T-.!0—S, RIE _ SCALE 1#�=4.0' �1 r m Z 0 ON NOTE: FLORIDA BUILDING CODE 2014- 5TH EDITION AFF GUIDE TO ALUMINUM CONSTRUCTION 2010 RESIDENTIAL- MAX MANO SPEEO-130 MPHAXPOSURE "B" 2015 FLORIDA STATUTE 489.113 SECTION 9 (B) STATES: 'ANY STRUCTURE UNDER 1,200 SQUARE FEET DOES NOT REQUIRED AN ENGINEER'S SIGNATURE. FOR THE PURPOSE OF ISSUING BUILDING PERMITS, LOCAL BUILDING OFFICIALS SHALL ACCEPT SUCH DRAWINGS, SPECIFICATIONS, OR PLANS WHEN SUBMITTED BY ANY LICENSES CONTRACTOR. 9' - 0" 3" X .024' ELITE ROOF. FL7561-R3 ATTACHED TO FASCIA T-9" CLEAR SPAN 2X3 2X3 SCR SCR x cli DOOR cm 2X3 2X3 KP KP 1X3 1X3 2'-8" 9'-0" VIEW "A �SE W19 Apo FASCIA HOUSE X -X SLIDI OOR I REP CEME — — — — — — — — — — — — J — — — — — 1 I I I I I P i o a I b cr W I I ~ W b I J w I Lu c I I I a--- --n-- ----a ----- ---- SEE VIEW "B" I L------------ 29-0" ELITE ROOF U W W Z O J U _ w U W � O Z 0 N w LU rci can Y , W W z fA W a a }} u } 3 w 2X3 N O " SCR SCR SCR SCR x CV O x J Fa- � z c o CV s _ .2 x x x x ® Lo N N N N a$ L6 x x r, 2X3 2X3 2X3 2X3 KP —11 KP KP 1X3 KP 4'-91/2" 4'-9112" 4'-9112" 4'-9112" 9'-9" 9'-9" VIEW "B" U W W Z O J U _ w U W � O Z 0 N w LU rci can Y , W W z fA W a a }} u } 3 w W {y O m O O O V 0 8 o0 oz°° `y O J U v u d D J Fa- � z c o ?(n 3 i a w00 ® Z r oc a$ L6 NOTE: FLORIDA AFF GUID RESIDENT 2015 FLC STATES: 'ANY STI ENGINW LOCAL 8 OR PLAN iUILDING CODE 2014- 5TH EDITION E TO ALUMINUM CONSTRUCTION 2010 AL- MAX WIND SPEED -130 MPH/EXPOSURE RIDA STATUTE 489.113 SECTION 9 (9) tUCTURE UNDER 1,200 SQUARE FEET DOES NOT REWIRED AN 'S SIGNATURE. FOR THE PURPOSE OF ISSUING BUILDING PERMITS. S W14EN StJJB TTTED�BYLL ACCEPT SUCH DRAWINGS. ANY LICENSES CONTRACTOR..aFlCATfONS. 14'-0" EXISTING PATIO NtVV GUNUKt I t NEW 4" CONCRETE SLAB, 6" THICKENED EDGE, 3000 PSI w/ FIBERMESH. 6 mil w/ VAPOR BARRIER, TERMITE TREAT. (NEW CONCRETE POURED OVER EXISTING PATIO SLAB. V Se- S► kc, Bonalti,5 Atie„fi U W Z g cf) W U j W O1u-W C;Q m N Y U 0-M m a o 0 U N ao Z r % lo O J wam ~ �. Q d J & Z o Lno of 3 C%3 Z a � oOc Z ui ® R O 0 J Q an o REQUIRED INSPECTION SEQUENCE BP# IG , Address: BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building Other REVISED: June 2014 ELECTRICAL PERMIT Min I Max I Inspection Description Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Final Min Max Inspection Description Gas Underground Gas Rough . Gas Final