HomeMy WebLinkAbout500 Fox Quarry LnV NOVECEIVEt 2 s 20% 1�ems} --- Application No: Job Address: 500 Fox Quarry Lane CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Documented Construction Value: $1309.00 Historic District: Yes ❑ No 9 Parcel ID: 12-20-30-300-012,&-0000 Zoning: S1-SANFORD Description of Work: BLD 9 SK5207 needed to be replaced, due to damage, with SK5208 Plan Review Contact Person: Sheena Willis Title: Project Coordinator Phone: 407-274-5443 Fax: 407-816-9104 E-mail: swilli0aitli.fesafety.corn Property Owner Information Name CHARLESTON CLUB PARTNERS LTD Phone: Street: 7935 C/O CONCORD MGNMT, LTD Resident of property? : No P O BOX 940279 City, State Zip: Contractor Information Name AIT Life Safety. Ozzie Molina Street: 4617 Parkbreeze Court Phone: 407-816-9101 Fax: 47-816-9104 City, State Zip: Orlando, Florida 32808 State License No.: EF0001116 Architect/Engineer Information Name: Phone: Street: City, St, Zip: Bonding Company: Address: Building Permit O Square Footage: _ Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type No. of Dwelling Units: Flood Zone: Electrical O New Service - No. of AMPS: Mechanical 0 (Duct layout required for new systems) No. of Stories: 0J Plumbing O 6% \�A New Construction - No. of Fixtures: Fire SprinklerhED3 Sprinkler/EDNo. of heads: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. if the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owncr/Agent Print Owncr/Agent's Name Date Signator: of Notery•Sate of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 Signature of Cdfiwctor/Agent Dole Print Cont racto Agent's me 4., signottu f oary-S tc of Florida Date Contractor/Agent is ✓ Personally Known to Produced ID Type of ID UTILITIES: WASTE WATER: l FIRE: BUILDING: 12 I I aq 1/ ��r� J t f-jC S a}IC-'t J (Ir2t7-0 r�� SINGLE SOURCE SOLUTION FIRE ALARM -SPRINKLER -SECURITY 4617 Parkbreeze Court Orlando, FL 32808 407.816.9101 (P) 407.816.9104 (F) www.AITLifeSafety.com State Certified Contractor (Fire) EF20001116 (Sprinkler) 20112800012010 Fire Alarm Panel Replacement Proposal CUSTOMER NAME: Concord Management 2605 Maitland Center Parkway Maitland, FL 32751 DATE: 11/15/2016 PROPERTY NAME: Charleston Club 500 Fox Quarry Lane Sanford, FL 32773 AIT Life Safety thanks you for the opportunity to submit a proposal for your life safety needs. Scope of Work: 1 AIT proposes to replace the fire alarm panel from an existing 5207 to a 5208 due water damage at building #9. Qty Item Description: 4 Labor Hours $ 115.00 $ 460.00 1 SK 5208 $ 846.00 $ 846.00 Total Price $ 1,306.00 ADDITIONAL NOTES 1) Proposal is valid for thirty (30) days from date listed. 2) Proposal is based on labor hours listed above, any alterations or deviation from the above scope of work will be considered an adder (If applicable, suites or units will be accessible to perform the above work) 3) Price is based on normal working hours Monday - Friday 7:30am - 5:00pm 4) Any patching, cutting and/or any other drywall, framing work will be repaired by owner or owner's rep. 5) AIT will provide a one year warranty covering materials & labor, excluding acts of nature, theft, vandalism, & tampering 6) Equipment rentals are excluded, unless noted above. 7) If plans are needed for the work specified above it is the owner's responsibility to provide (FA or electrical) in CAD or PDF form 8) If permitting fees are not specified above and fire marshal requires permit, the fee will be added to the final invoice. 9) AIT or its employees aren't electrical contractors. If 120VAC is needed the owner or owners rep will be responsible to hire electrical contractor. 10) Keys or access will be granted by owner or owner's rep to perform the work above. If technician is onsite and access is not granted after work has been scheduled AIT will invoice a two (2) hour minimum at your current labor rate. 11) If applicable, phone lines and network (IP Address) will be provided by owner or owner's rep. ACCEPTANCE OF PROPOSAL The above prices , specifications and conditions are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. The terms and conditions contained 5=;�� eement are Incorporated herein and by reference made a part hereof. ACCEPTED: `� %, AIT LifeSafety: Date Date: CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $1309.00 Job Address: 500 Fox Quarry Lane Historic District: Yes ❑ No 9 Parcel ID: 12-20-30-300-012X-0000 Zoning: S1-SANFORD Description of Work: BLD 9 SK5207 needed to be replaced, due to damage, with SK5208 Plan Review Contact Person: Sheena Willis Title: Project Coordinator Phone: 407-274-5443 Fax: 407-816-9104 E-mail:swillis@aitlifesafety.com Property Owner Information Mo Name CHARLESTON CLUB PARTNERS LTD Phone: Z..!— D Street: 7935 C/O CONCORD MGNMT, LTD Resident of property? : No P O BOX 940279 City, State Zip: DIAITLANE), F;6 92:;94 92:79DR Contractor Information Name AIT Life Safety, Ozzie Molina Street: 4617 Parkbreeze Court City, State Zip: Orlando, Florida 32808 Name: Street: City, St, Zip: Bonding Company: Address: Building Permit O Square Footage: _ Phone: 407-816-9101 Fax: 47-816-9104 State License No.: EF0001116 Arch itect/E n9ineer Information Phone: _ Fax: E-mail: _ Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Stories: No. of Dwelling Units: Flood Zone: Electrical O New Service - No. of AMPS: Mechanical 0 (Duct layout required for new systems) Plumbing 0 New Construction - No. of Fixtures: Fire Sprinkler/ larm No. of heads: I ("r -a --CO P - E- 6- - Fb Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. V Signature ofOwncr/Agent Date Signature ofC tractor/Agent Date Print Owncr/Agent's Name Signature of Notary•Suatc or Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: COMMENTS: Rev 11.08 Print of Florida Date Contractor/Agent is ✓ Personally Known to N Produced ID Type of lD UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING:_ fz'r-4 PERMIT# !4' — S/ 9 2 OFFICE y e s- nrr J� gy `--- SINGLE SOURCE SOLUTION FIRE ALARM -SPRINKLER -SECURITY November 16, 2016 City of Sanford 300 North Park Ave Sanford, A 32771 Re: Narrative letter describing scope of work to be performed Project Nome: Charleston Club Project Address: 500 Fox Quarry Lane Building 9, Sanford, FL 32773 Building Permit C NA To whom it may concern: Please allow this narrative letter by AIT Life Safety to be used for permitting and approval purposes for the change in monitoring for the existing fire alarm system at the above referenced project. AIT Life Safety will remove the existing Silent Knight 5207 Fire Alarm Control Panel that has been damaged and cannot be repaired and as such will be replaced it with a Silent Knight 5208 Fire Alarm Control Panel. As the existing fire alarm control panel is being replaced with a "like -for -like" fire alarm control panel battery calculations will not be necessary for this work. AIT Life Safety will re -use the existing field devices that are located at this property as they are compatible with this panel, including an existing smoke detector. Please do not hesitate to contact me if there is any additional information that is needed regarding this matter. Respectfully, Sheena Willis Permit Coordinator 4617 Parkbree=e Court Orlando, Florida 32808 Phone: 407 816-9101 ' Fax: 407 816-9104 EF 0001116 SILENT KNIGHT FIRE SYSTEMS® COMMERCIAL FIRE ALARMS 4=Mil -1 • Eight zones, 6 Style A (class B) and 2 Style D (class A). 8E ' xpander Zones are Style A (class B). Zones are intrchangeable using the Model 7181 Zone Converter. • UL, FM, MEA (BSA), CFM Listed and Approved. • Event memory. • Fuseless design can reduce service time. • Field selectable, 12 or 24 VDC power,supply. • Six amp current output at 12 volts, five amps at 24 volts. • Compatible with 2- and 4- wire smoke detectors as well as water flow and sounding devices. • ANSI Cadence Pattern Output. • Four programmable (Style Y) supervised signal circuits, including steady, pulse and temporal. • Programmable smoke verification, pre -alarm delay, and cross -zoning can minimize false alarms. • Four general purpose relays (Form C 24 volts at 2.5 amps resistive). • Built-in approved digital communicator with UL required.priorty_reporting. _ . _ _... _... .. • Flexible programming capabiities including up/ downloading and use of remote annunciator. No "desktop" programmer required. • Accu -Zone° diagnostics facilitate local and remote troubleshooting. • Individual zone Walk Test. DESCRIPTION: The Model 5207 is an all4n-one fuseless local fire evacuation control panel and digital communicator designed for applications requiring manual fire alarm, automatic fire alarm and water flow for sprinkler system supervision. The basic unit offers fire alarm for one to eight zones, expandable to 16 with the optional 5210 expansion module. It is compatible with both two- and four -wire smoke detectors. Compact, easy to install and service, it delivers the features you'd expect to find in fire systems costing much more. During normal operation, the 5207 constantly checks smoke and other sensing devices for fire conditions. It also conducts system checks to determine If any troubles, 5207 or system problems, exist. If the 5207 encounters a fire or trouble condition, it sends a report to a central monitoring station (if applicable), and, typically, sounds an audiblelvisual warning in the local area. The 5207's microprocessor constantly runs programs to check inputs and carry out other routine functions. If the program ever stops running, a watchdog circuit will detect it and reset microprocessors to resume normal operations. The Model 5207 conducts an automatic self -test every 24 hours—at a time you select—and sends a report to the central station (if applicable). Other features of the system include English-language remote annunciation simplifying `.Step Programming' of custom options. Remote downloading of system configurations can eliminate the expense of sending out a service technician for reprogramming. System provides a built-in fire drill procedure. The exclusive Accu -Zone° feature measures and displays zone voltages, so you can set up and test the system without separate testing equipment. Fuseless circuit board design eliminates one of the most likely causes for service calls. PROGRAMMING 5521 On-site programming is available through the optional Model 5521 Desktop Programmer or through any remote annunciator. Remote programming can be accomplished through the use of 5521 programmer and 5530 modem, or through the use of an IBM or compatible personal computer and the Model 5541 Downloading Software (requires the Model 5530 Downloading Modem). More than 60 programmable options are available for customizing system configurations and end-user features, including zone type (fire, panic, tamper, sprinkler, water, heat, cold, local); zone options (pre - alarm delayed, smoke verification delayed, zone disable); and zone location descriptions. Programmable dialer options include total number of reporting attempts, Touch - Tone° or rotary dialing, one or two telephone lines. Several time delay features, including number of seconds to alarm in pre -alarm, smoke delay conditions, number of hours before loss of AC hours report, and 24-hourtest time, can be programmed. ZONE EXPANSION The optional Model 5210 Zone Expander doubles the number of zones available to the 5207 from 8 to 16. The 5210 adds eight additional style A,(class B) zones to the 5207, enabling use of both two- and four -wire smoke detectors. Voltage Ranges: Using 24-VDC power: 17.8-27.4 VDC. Using 12-VDC power: 8.5-11.8 VDC. 5210 ANNUNCIATION The 5207 Includes an annunciator inside the cabinet. Its six LEDs (for alarm, trouble, silenced, ACAow battery, event memory, time set/reporting) are visible without opening the cabinet. The annunciator allows for easy operation of all functions. Itfeatures dual seven -segment display and 14 uniquely assigned function keys. Keys are: ENTER, CLEAR, SILENCE, SHUNT and 0-9 used forALARM RESET, CLEAR ALARM MEMORY, DIALER RESET, REQUEST DOWNLOAD, DISPLAYMEMORY, TEST, DISPLAY TROUBLES, SET DATE and SET TIME. Remote annunciation is available through the Model 5230. This four -wire, 16 -=one remote annunciator is easy to operate. Its fourteen function keys can perform the same operations as the main system annunciator, including silencing, resetting, and displaying of alarms, troubles and alarm memory. Use of access codes prevents unwanted tampering. In addition the Model 5230 can be used to program all programmable options for both the local control and digital communicator. Features include LCD display, backlighting, English- language annunciation. Up to seven 5230s can be attached to one 5207. Standby current draw per 5230 is 60 mA, alarm current is 120 mA. 5230 COMMUNICATIONS/REPORTING The 5207 is equipped with a UL listed digital dialer which has the ability to seize the telephone line(s) to report alarms and troubles to a central station. It can supervise the telephone lines and activate a trouble - alert if a line failure is sustained for 45 seconds or longer. Other communications/reportingfeatures include: Built- in ring detector; re -try if communication failed; fail -to communicate output; one or two phone lines option; up to four phone number capability (plus computer phone for downloading); Touch -Tone° and rotary compatible. The 5207 is compatible with all major reporting formats including SIA (security industry standard), SK, FSK, SK 4/2, Radionics BFSK. Format selectable by account number. SPECIFICATIONS ELECTRICAL SPECIFICATIONS: • Primary AC: 120 VRMS at 60 HZ, 2A • Total Accessory Load: 5A at 24 VDC 6A at 12 VDC INDICATOR LIGHTS: • AC/DC POWER (Green) - On when system is running on AC power; flashes when using DC. • ALARM (Red) - On for supervisory alarm; flashes for fire alarm. • TROUBLE (Yellow)- On when trouble condition exists. • SILENCED (Yellow) - On when alarm or trouble has been silenced but not yet cleared. • EVENT MEMORY (Yellow) - On when an alarm condition has been reset. • SET MODE/REPORT (Yellow) - On when system is in test or program mode, including Date/Time set mode. Flashes when system is reporting. MECHANICAL SPECIFICATIONS: • Dimensions: 16 in. W x 26.4 In. H x 4 in. D (40.6cm W x 67cm H x 10.2cm D) • Weight: 25 lbs. (11.4 kg.) • Color. Red TELEPHONE REQUIREMENTS: • FCC Registration No.: AC6USA-W75-AL-E • Type of Jack: RJ31X (2 required) APPROVALS: • UL Listed • FM Approved • CFM Approved • New York City MEA (formerly BSA) • NFPA - Central Station Reporting - Local Protective Signaling System - City Box - Polarity Reversal - Proprietary Protective Signaling System OPTIONAL ACCESSORIES Model 4180 Status Display Module Provides 16 outputs to give alarm and trouble conditions by zone. Two units can be connected to annunciate all 16 zones on a 5207 control. Can be used to drive LED or graphic annunciators. (Non -supervised) Model 7181 Fire Zone Convertor Converts Style A zones to Style D and vice versa. 5220 Direct Connect Module Used for City Box and polarity reversing direct wire applications. 5530 Downloading Modem SIA format modem for remote programming of 5207. 5541 Downloading Software For remote programming with IBM PC and compatible computers. Can be used with 5207. Requires 5530 modem. Software/modem package may be ordered as a 5561. 5260 Printer Interface Allows connection of a standard computer printer to provide a printed record of 5207 system activity. Simple plug-in connection. (Printer not supplied.) ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall provide a complete electrically supervised fire alarm and communications system. The system shall contain a fire alarm controllcommunicator and panel to supervise and operate heat and smoke detection devices, alarm signal devices, visual annunciators and an integral digital communicator to transmit fire alarm and supervisory signals to a central station. The controllcommunicator shall be UL Listed or FM approved for use under NFPA 71, 72A, 72B, 72C and 72D standards. It shall provide power and control for eighlsupervised detection zones, foursupervised alarm signal circuits and a dual digital communicator. The control/ communicator shall be expandable to sixteen supervised detection zones and shall be able to communicate to a central station in SIA, SK FSK1, SK 4/2 or Radionics BFSK formats. The control/communicator shall be Model 5207 or approved equal. There shall be two Style D and six Style A detection zones. They shall accommodate heat detectors, products of combustion detectors, manual pull stations, sprinkler flow switches and gate valve supervisory switches Intermixed as desired and permitted by NFPA 71, 72A, 72B, 72C, and 72D. Products of combustion detection may be either two- or four - wire and shall be cross listed by UL for use on the system. The detection zones shall be programmed to (1) be cross zoned so that two Individual zones must sense products of combustion, (2) autoinatically reset a detector to verify that smoke exists, (3) see a single detector in alarm—before the alarm is sounded and a signal is transmitted to the central station. There shall be four 1 amp supervised (Style Y) alarm signal circuits. They shall cause the bells/homs to ring steady/ pulsing/temporal throughout the premises until reset or silenced. Two 1 amp outputs can be combined to provide one 2 amp output. The control shall be equipped with four auxiliary relays that shall be programmed to operate on (1) pre -alarm, (2) tamper alarm, (3) special alarm, (4) fire alarm, (5) trouble, (6) no - silence, (7) alarm by specific zone (1-16). The relays shall remain energized until the panel is silence reset or the trouble condition is cleared, unless 'no -silence' is selected. The controllcommunicator shall have an Integral annunciator to indicate sequentially zones In alarm, zones in trouble, and system functions. LEDs shall augment the display to make Gear to an operator the system status. An integral touchpad shall be provided to operate, set up, and interrogate the system. Vital operations such as alarm silencing or reset shall be simple and obvious to an operator. Authorization pass codes may or may not be used. The controllcommunicator shall have the capability to supervise two telephone lines, seize the phone line, and send the alarm signal on one or both lines without the addition of any more equipment. it shall sound a local trouble signal if the telephone service is Interrupted for longer that 45 seconds and it shall transmit a signal indicating the loss of phone line service to the central station over the remaining phone line. A signal shall also be transmitted indicating the restoral of phone service. The control/communicator shall be able to report the loss of either phone line without regard towhich phone line failed first. If both lines fall, a local signal shall sound. The conlrolfcommunicator shall have the ability to send a test signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night by setting a program within the panel. The alarm signals transmitted to the central station shall indicate which of the eight zones is In alarm and which zones are in trouble, depending on which format is used. Restoral from alarm or trouble shall also be transmitted by zone. The controllcommunicator shall be capable of communicating to Silent Knight, Radionics or Ademco central station receivers. ............r...... a am wA� SUNT Mr J VW Jra.9N • u.J . Jam of WOh 3801 Jr►! COsµ fdrwrtat6J 1 Wrh.y MODEL 5207 BLOCK DIAGRAM - TYPICAL INSTALLATION 7750 Meridian Circle. Maple Grove, MN 553694927 MADE IN SILENT 1 -M448 -i444 or in Minnesota (612) 4936435 AMERICA KNIGHT FAX: (612) 4836475 Form 015076 (Rev 6166) FIRE SYSTEMS• 3 SILENT Model 5208 KNIGHT Fire Alarm Control Panel by Honeywell with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK -5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK -5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK -5208 delivers the performance to handle your installation. Features • 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones • Supervised zone expanders and UO modules can be mounted remotely from the main control panel • Event History Butler (150 events) with date/Ume stamp • All zones are compatible with 2• or 4 -wire detectors • 8 selectable/programmable output patterns for notification appliance circuits • Builtwin Digital Alarm Communicator Transmitter (DACT) • 4 Notification Appliance Circuits - 4 programmable general purpose relays • Programmable smoke verification, pre -alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms • Programmable from the buiftwin control panel touchpad, remote annunciator, or Windows® SKSS downloading software • Direct connect port for on-site up/downloading with Windows® SKSS downloading software • Builtrin walk test feature • Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a dear window, limiting access to the panel while providing single button operation of the reset and silence functions • Programmable AC trouble relay • Buil[-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® • Programmable date settings for Daylight Saving Time • Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's Internal dock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75' (62.9 cm) Width: 14.5' (36.8 cm) Depth: 3-7/16' (8.73 cm) with 5/8' protruding Overall Dimensions: Height: 26-3/8' (67 cm) Width: 17-3/16' (43.66 cm) Total Depth: 4' (10.16 cm) Operating Temp: 32' to 120' F (0' to 49' C) Humidity: 10 - 93% noncondensing Optional Accessories • SK -5235 LCD Remote Annunciator • SK -5217 10 Zone Expander (2 max. per system) • SK -5280 Status Display Module (8 max. per system) • 5220 Direct Connect Module • 5824 Serial/Perallel Printer Interface Module • SKSS Downloading Software SK -S208 • Plex-2 Door Option • SK -SCK Seismic Compliance Kit Listings and Approvals • UL Listed • CSFM Listed • MEA approval 429-92-E Vol. XIII • OSHPD (CA) OSP-0065-10 Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 2 Class A (Style D) or Class B (Style 8 Initiation Circuits. 8 Class B (Style B) Initiation Circuits To AC Telephone Line 2 Direct Connect For On -Site Programming Programmable Form C Relays I Notification .i Appliance Circuits of 15235 Remote e ^ aoo Annunciators �♦ SBUS Devices 5280, 5217, & 5824 This document Is not intended to be used for installation purposes. We by to MADE IN AMERICA SILENT keep our product Information up4o-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORME! 350318 Rev E • subject to change without notice. For more information, contact Silent Knight ® 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax (203) 484-7118. For Technical support, Please call 800-446-0444. www.sllentknight.com .