HomeMy WebLinkAbout1220 30 St9
i
RECEIVED
i
MAY 17 2011 CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: Documented Construction Value: S 3(3 745,, O O
job :address: 13.21.0 3 S 1 44Q Historic District: Yes No
Parcel tDc 0(o- e?-0,,,,-3 l O -=1 O 0 zoning:
Description of Work: CL*i 0"1— 10 (_+4eo,
Plan Review Contact Person: Title:
Pl orae: Fax: E=snail:
Property/ Owner Information
Nance-Irp,x4 I" Phone: 40) - 5'yS( - g p
00 n
Street: / E1 f?e I .,ol/ i B y Resident of property?
Cay, State Zip: !SqD d
Contractor Information
Name BARNES HEATING &
Phone:
Street: 915 W. 2ND Si.
NFORDrEl 3277f Fax: SA
City, State Zi Z-3511 a W (407) 321-: X
p: State License No.: CJ4Gc 3 LSG
Architect/Engineer Information
Name Phone:
Street: Fax:
Cit%! St, Zip: E-mail:
Bonding Company:
Address
Building Permit
Square Footage -
pro_ of Dwelling Units:
Mortgage Lender:
Address:
PERMIT INFORMATION
Construction Type: No. of Stories:
Flood Zone:
Electrical
New Service - No. of AMPS:
i xechanical (Duct layout required for new systems)
Plumbing
New Construction - No. of Fixtures:
Fire Sprinkler/Alarm 11 No. of heads:
r-- -
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no
Work or installation has commenced prior to the issuance of a permit and that all work will be performed to
meet standards of all laws regulating construction in this. jurisdiction_ I understand that a separate permit
must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and
air conditioners, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and .that all work will
he done in compliance with all applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this
property that may be found in the public records of this county, and there may be additional permits required
from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida
Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order
to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the
plan review fee based on poul 11"Aovi Should calculated charges exceed the documented
construction value when the execute& &—'KirUt 's tubmitted credit will be applied to your permit fees when the
WNT ff
permit is released. tPIV, 0314011!01130
EVE 1`1 R,, iw wl.s eS CO
Signature of Owner/Agent Date- Signature of Contractor/Agent Date
Print Owner/Agent's Name Print on ractor/Agent's Name
S ' 7 llSignatureofNotary -State of Florida Date Signature o a - Date
dr
sty 0
Bo Od'
Jv •.
p rhrmywn
Owner/Agent is Personally Known to Me or Contractor/Aben\' Personally Kno to Meor Produced
M ...Type of ID Produced M Type of ID —lam APPROVALS:
ZONING:*.' UTILITIES: WASTE WATER:' ENGINEERING:
FIRE: BUILDING: COMMENTS:
Rev
11.08
Seminole County Property Appraiser Get. Information by Parcel Number Page I of 1.
PROPERTY
APPRAISER
5rt,111,10- ECOUNTY 1.
12111 I.Ul? E 3l)TH qT
VALUE,SUMMARY
GENERAL
VALUES
2011 2010
Certified
Value Method Cost/Market Cost/Mark at
Parcel Id: 06-20-31-300-0010-4100
Number of Buildings
I
Omer: SANFORD ARPRT AUTH/CITY SANFRD
Depreciated Bldg Value 110,458 115,718
Own/Addr: C/O REAL DEAL STEEL
Depreciated EXFT Value 2,076 2.076
Mailing Address: 1220 30TH ST
Land Value (Market) 0 0City,State,ZipCode: SANFORD FL 32773
Land Value Ag 0 0PropertyAddress: 1220 30TH ST SANFORD 32773
112,534 117,794FacilityName: OSIA; WHISPER JET
Portablity Adj 0 0TaxDistrict: Sl-SANFORD
Exemptions; Save Our Homes Adj 0 0
Dor: 48-WAREHOUSE-DISTR & ST Amendment I Adj 0 0
Assessed Value (SOH), 112,5341 117,794
Tax Estimator
2011 TAXABLE VALUE WORKING ESTIMATE.
Taxing Authority Assessment Value, Exempt Values, Taxable Value
County General Fund 112,534 0 112.534
Amendment 1 adjustment is not applicable to school assessment) -Schools 112,534 0 112,534
City Sanford 112,534 0 112,534
SJWM(SaInt Johns Water. Management) 112,534 0 112,534
County Bonds 112,534 0 112.534
The taxable values and taxes are calculated using the current years working values and the prior years approved millage rates.
SALES
2010 VALUE SUMMARY
Deed Date Book Page Amount Vac/Imp Qualified
2.W) Tax Sil Anwkint: $0
2010 Ccilifigii Vaiue ind Taxes
DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS
Se 's
LAND' LEGAL DESCRIPTION
Land Assess Method Frontage Depth Land Units Unit Price Land Value
LOT 0 0 1.000
LEG SEC 06 TWP 20S RGE 31E BEG 450 FT E & 145 FT S
OFINT29THST&MELLONVILLEAVE RUNE 13OFTS70 FT
W 130 FT N 70 FT TO BEG BUILDING INFORMATION
Bid Num
Bid Class Year Bit Fixtures Gross SF Stories Ext Wall Bid Value Est. Cost New 1 STEEL/
PRE ENG 1972 0 9,301 1 METAL PREFINISHED $110,458 $262,996 EXTRA FEATURE
Description Year
Bit Units.EXFT Value Est. Cost New COMMERCIAL CONCRETE
DR 4 IN 1972 2,436 $2,076 $5,189 NOTE:'Assessed
shown and therefore subject to change before being finalized for ad valorem tan, purposes. pa recent" =. . ===,ar
exty
ear'sroperty tax will be based an JustlMarket value. http://www.
scpafl.org/-vveb/re—web.seminole_county.title?parcel=06203130000104100&c... 5/17/2011
BARNES
HEATING & AIR CONDITIONING, INC.
Proposal 915 West 2nd Street
Sanford, Florida 32771
407) 323-3517
NAME PHONE
SANFORD AIRPORT
STREET JOB NAME
1220 30TH STREET
CITY . ST ZIP JOB LOCATION
SANFORD - FL 32773 BUILDING # 410
ESTIMATE
HEAT PUMP MODELS
OPT 1. PAYNE.BY'CARRIER.(2 TON) MODELS PH13ANA024000 / PF4MNA025TOO
22400 BTU'S COOL @ 13.0 S.E.E,R
21000 BTU'S HEAT @ 7.7 HSPF
10 KW AUXILLARY HEAT STRIP
MANUFACTURERS 5 YR COMPRESSOR
1 YEAR PARTS
1 YEAR BARNES LABOR
DATE
5/611
JOB PHONE
3976.00
PRICE'FOR ABOVE ALSO INCLUDES REMOVAL OF OLD EQUIPMENT, TIE BACK INTO YOUR -EXISTING DUCTS
AND, ELECTRICAL, NEW PAD, NEW FREON LINES, NEW DIGITAL THERMOSTAT, PERMIT AND LABOR
I
WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR --COMPLETE IN ACCORDANCE WITH ABOVE SPECIFICATIONS;
FOR THE SUI ` SEE ABOVE
Payment to be made as follows:
PER iNvnior 'IPON C:OMPI FTION` .ASH f,Hf=rK VISA OR MC'
AU#hOrIZ@d SlgtlatUf@
THOMAS GOCHEE .
All material is guaranteed to be as specified. All work to be completed in aworkmanlike
manner according to standard practices. Any alteration or deviation from above specifiea-
Lions involving extra costs"will be executed only upon written orders, and will become an
extra charge, over .and above the,estimate. All agreements contigent upon strikes, accidents
or delays beyond our, control. Owner to carry fire, tornado and other necessary insurance.
Our workers are fully covered by Workmen's Compensation Insurance.
Note: This proposal may be
withdrawn by us..if not accepted
within 30 _d,ays.
Acceptance of Proposal
The above prices, specifications and conditions are satisfactory and are hereby
Si naaccepted. You are authorized to-do the work as specified. Payment will be made ture
as outlined above..
Date of Acceptance:" oZ Signat
AHRI Certified Reference Number: 4341721 Date: 5/6/2011
Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source
Outdoor Unit Model Number: PH13NA024" "B
Indoor Unit Model Number: PF4MNA025
Manufacturer: PAYNE HEATING AND COOLING
Trade/Brand name: PAYNE PH13
Manufacturer responsible for the rating of this system combination is PAYNE HEATING AND COOLING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 22400
EER Rating (Cooling): 10.60
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 21000
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh) @ 17 F: 13000
Ratings followed. by an asterisk (') indicate a voluntary rerate of previously published data unless accompanied with a WAS. which indicates an involuntary rerate
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes.
The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any
form or manner or by any means, except for the user's individual, personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org' MIMI Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institutewhichthecertificatewasissued, which is listed above, and the Certificate No., which is listed below.
2011 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129491653885126220