HomeMy WebLinkAbout2300 Old Lake Mary RdMAY 10 2011
AITY OF SANFORD
RE PREVENTION
PERMIT APPLICATION
Application No: 11 ,_. I q ( ] Documented Construction Value: $ 40 00. O 0
Job Address: Z 3100 0 L_ Q l-/4 IC.0 (A Aga &o
Parcel ID: 33 -19 - 30 - 50,H' 0600 - 0 58 F
Historic District: Yes No
Zoning:
Description of Work:I' E 4CL C -7C Sfi G 3r- 5 Za q "` (J l i VIOd 2 Jr Unng A P
Plan Review Contact Person: so Title: L"QgAre \0A1)f/+4CQ,
Phone: yap- 7/,2- IK g/ Fax: qo7 - 7/2 -X813 E-mail: I 0-a 4,ro n (,o ad' F Cay!
r,4fl,4G,,A
Property Owner Information
Name L"JA-,4—r `I_,J-- Phone:
Street: 3S0 Ti Ael'i e CKs J) K.- Resident of property?
City, State Zip: rr ++ KL re r ,n d C- 32-7e
A I
d
Contractor Information
l f-7/2-- Name S E Ct> 2 i - Phone: '4o -7 - -7 / 2-- " 0 g
Street:3 i 6o (2 M erre. &V4 *3' Fax: q0_7 --712-- V ( 3
City, State Zip: or I AA , FL 3z B0( -o State License No.: SE Zaaw p jo
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Building Permit
Architect/Engineer Information
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
PERMIT INFORMATION
Square Footage: Construction Type: No. of Stories:
No. of Dwelling Units: Flood Zone:
Electrical
New Service - No. of AMPS:
Plumbing
New Construction - No. of Fixtures:
Mechanical (Duct layout required for new systems) Fire Sprinkler/Alarm No. of heads:
N C oNTYZ-,AWT .
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no
work or installation has commenced prior to the issuance of a permit and that all.work will,be performed to
meet standards of all laws regulating construction in this jurisdiction. I understand that a separate -permit,
must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and
air conditioners, etc.
OWNER'S AFFIDAVIT:. I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this
property that may be found in the public records of this county, and there may be additional permits required
from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida
Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order
to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the
plan review fee. based on past permit activity levels. Should calculated charges exceed the documented
construction, value when the executed contract is submitted, credit will be applied to your permit fees when the
permit is released.
Signature of Owner/Agent Date
Print Owner/Agent's Name
Signature of Notary -State of Florida Date
Owner/Agent is Personally Known to Me or
Produced ID Type of ID
APPROVALS: ZONING: UTILITIES:
ENGINEERING: FIRE:
COMMENTS:
Rev 11.08
Signature ontracto gent Date
R ca MC
Print Contractor/Agent's Name
Signature of Notaryto of oridaNANCY GIBW4
NOTARY PUBLIC
STATE OF FLORIDA
Comm# DDO4_0EXpIres 3/2812014
Contractor/Agent is L-,-Pe-rsonally Known to Me or
Produced ID Type of ID
WASTE WATER:
BUILDING:
ADT Security Services Inc
3160 Southgate Commerce Blvd
Suite 38
Orlando, FL 32806
Tele: 407-712-1620
Fax: 407-712-1813
LIMITED POWER OF ATTORNEY
I hereby name and appoint Nancy Gibson, Juan Cortes or Bill McMahon of ADT
Security Services to be my lawful attorney in fact and apply To Sanford
for afire alarm permit for work to be performed at the following location.
These individuals may perform all duties necessary in procuring this permit.
2300 Old Lake Mary Rd
Job address
Creative Printing
Project Name
And to sign my name and do all things necessary to this appointment.
I _k VK'I'z'
Bert McCue, Certified Contractor, License# EF20000890
State of Florida, County of Orange
Personally known to me and acknowledged:
Sworn to and subscribed before me this /L
h
day of A.D. 20//
QIP
Notary Public, State of Florida. CIO
Notary Public State of Florida
t. ;,..:<i Diane Williams
y my Commission DD912963
OF n"
Expires 10/18/2013
My C 1 0
Seminole County Property Appraiser Get Information by Parcel, Number
Personal Property Please Select Account
Page 1 of
1 T 9, 191
11 d. 31'
DAIVID JOHNSON CFA,ASA 1d 57.A ti*'? R
f+f[
jB 57.B, 32 a+ai
r`'
kt
70
3
sEi 1iNC3LEi:0UNTYFL a` 11
1101 E. -FIRST ST 1 .5 58.D 58.A
1a, 1
9ARFORD, FC 32Tf1-1465
407 66H -"75C)&
r a bra
4'0
20 1 41'P 1.221 23 T7 rt
VALUE SUMMARY
VALUES
2011 2010
Workina Certified
GENERAL Value Method ...-Cost/Maiket Cost/Market
Parcel Id: 35-19-30-5CH-0000-058F Number of Buildings 1 1
Owner: PARAGON PRODUCTS INC
Depreciated Bldg.Value $389,875 $399;621
Mailing Address: 350 TWELVE OAKS DR Depreciated EXFT Value $6,578 $6,578
City,State,ZipCode: WINTER SPRINGS FL 32708 Land Value (Market) $131,770 $158,124
Property Address: 2300 OLD LAKE MARY RD SANFORD 32771
Land Value Ag $0 $0
Facility Name:
Just/MarketValue $528,223 $564,323,
Tax District: S1-SANFORD
Portablity Adj $0 $0
Exemptions:
Save Our Homes Adj $0 $0
Dor: 41 -LIGHT MANUFACTURING
Amendment 1 Adj $0 $0
Assessed Value (SOH) 1 $528,2231 $564,323
Tax Estimator
2011 TAXABLE VALUE WORKING ESTIMATE
Taxing Authority Assessment Value Exempt Values Taxable Value .
CountyGeneral fund $528,223 $0 $528,223
Amendment, adjustment is not applicable to school assessment),'`,'Schools $528,223. $0 $528,223
City.Sanford $528,223 $0 $528,223
SJWM(SaintJohns Water Management) 1 $528-,2231 $0 $528,223
County Bonds $528,2231$01.,$528;223
The taxable values and taxes are calculated using the current years working values and the prior years approved millage rates.: .
http://www.scpafl.org/web/re _web.seminole couptY_title? arcel=3519305CH0000058F&c ad=old lake m,'&c a- dnum=230.... 5/10/2011.
Seminole County Property .Appraiser Get Information by Parcel Number Page 2 of 2
SALES
Deed Date Book Page Amount Vac/Imp Qualified
WARRANTY DEED 12/2004 05543 0360 $725,000 Improved Yes
WARRANTY DEED 12/2004 05543 0359 $100 Improved No 2010 VALUE SUMMARY
ARTICLES OF AGREEMENT 12/2000 03982 1936 $558,000 Improved No 2010 Tax Bill Amount: $11,335
SPECIAL WARRANTY DEED 12/1993 02701 0218 $260,000 Improved No 2010 Certified Taxable Value and Taxes
CERTIFICATE OF TITLE 06/1992 02437 0860 $100 Improved No DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS
WARRANTY DEED 09/1986 01772 1198 $328,000 Improved Yes
WARRANTY DEED 11/1980 01307 0756 $100 Vacant No
Find Sales within this DOR Code
LAND LEGAL DESCRIPTION
Land Assess Method Frontage Depth Land Units Unit Price Land Value LEG E 265 FT OF N 200 FT OF S 336 FT OF LOT 58 MM
SQUARE FEET 0 0 52,708 2.50 $131,770 SMITHS 2ND SUBDR PB 1 PG 100 (1.21 AC)
BUILDING INFORMATION
Bid Num Bid Class Year Bit Fixtures Gross SF Stories Ext Wall Bid Value Est. Cost New
Building 1 STEEL/PRE ENG 1981 8 20,800 1
Sketch METAL PREFINISHED $389,875 $649,791
Subsection / Sgft CANOPY / 140
Subsection / Sgft OPEN PORCH FINISHED/ 2400
Subsection / Sgft CANOPY / 1600
Subsection / Sgft OPEN PORCH FINISHED/ 240
Permits
EXTRA FEATURE
Description Year Bit Units EXFT Value Est. Cost New
COMMERCIAL ASPHALT DR 2 IN 1981 15,400 5,606 $14,014
6' CHAIN LINK FENCE 1981 240 576 $1,440
LOAD WELL 1981 660 396 $990
VOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes.
If you recently urchased a homesteaded property your next ear's property tax will be based on Just/Market value.
ttp;J/wr>ti,w.scpafl.org/web/re_web,semnole_county_title?parcel=3519305CH0000058F&cpad=old lake mary&cpad_num=230... 5/10/2011
Ahways There
May 10, 2011
Sanford Fire Dept.
1303 S. French Ave.
Sanford, Florida 32771
Creative Printing 2300 Old Lake Mary Rd Sanford
ADT requests approval to replace the existing defective Silent Knight 5204
FACP with a new Unimode 5UD FACP at the above location per our plans and cut
sheets.
The replaced FACP will continue to have remote station monitoring by ADT's
UL Central Station.
Please refer to the drawing for device location(s) and contact me at (407)
712-1682 with any questions.
S' erely,
J n Cortes
Phone 407-712-1682
Fax 407-712-1813
Email jcortes@adt.com
0
DA -60186:131 • A2-150
Five Zone Fare Alarm Control Panel a ADT always Thea-
Ten Zone Fire /Marna Control Panel
ffi
45 t ,te " , 1 .,.a. ••^ .
General
The UNIMODE-5UD is a five -zone FACP (Fire Alarm Control
Panel) and the UNIMODE-10UD is a ten -zone FACP. These
control panels provide reliable fire signaling protection for
small to medium-sized commercial, industrial, and institutional
buildings. Both panels include built-in communicators for Cen-
tral Station Service and remote upload/download.
Each of these FACPs is compatible with System Sensor's
microprocessor -based i3 series detectors. These conventional
smoke detectors can transmit a maintenance trouble signal to
the FACR indicating the need for cleaning and a supervisory
freeze" signal when the ambient temperature falls below the
detector rating. Additionally, both the UNIMODE-51JID and
UNIMODE-10UD are compatible with conventional input
devices such as two- and four -wire smoke detectors, pull sta-
tions, waterflow devices, tamper switches, and other normally -
open contact devices. Refer to the ADT Device Compatibility
Document for a complete, listing of compatible devices.
Outputs include four NACs (Notification Appliance Circuits),
three programmable Form -C relays (factory programmed for
Alarm, Trouble, and Supervisory) and 24 VDC special applica-
tion resettable and nonresettable power outputs. The FACPs
supervise all wiring, AC voltage, battery level and telephone
line integrity.
Activation of a compatible smoke detector or any normally -
open fire alarm initiating device will activate audible and visual
signaling devices, illuminate an indicating LED, sound the
piezo sounder at the FACP, activate the communicator and
FACP alarm relay, and operate an optional module used to
notify a remote station or initiate an auxiliary control function.
New options include a UL listed printer, PRN -6F and the ACT
Internet Monitoring module.
Features
Listed to UL Standard 864, 9th edition.
Built-in DACT (Digital Alarm Communicator/Transmitter).
Style B (Class B) IDC (Initiating Device Circuit)
UNIMODE-5UD - five IDCs.
UNIMODE-10UD - ten IDCs.
Style Y (Class B) NAC (Notification Appliance Circuit) - spe-
cial application power
UNIMODE-5UD - four NACs.
UNIMODE-10UD - four NACs.
Notification Appliances may be programmed as
Silence Inhibit.
Auto -Silence.
3.0 A total system current for UNIMODE-5UD.
7.0 A total system current for UNIMODE-10UD.
Optional Dress Panel DP -51050
Optional Trim Ring TR -CE for semi -flush mounting.
24 volt operation.
Low AC voltage sense.
Alarm Verification.
PAS (Positive Alarm Sequence).
Automatic battery trickle charger.
Up to eight ANN -BUS annunciators:
Optional 8 zone Relay Module ADT ANN-RLY.
Optional LED Annunciator Module ADT=ANWLED,
Optional Remote Annunciator ADT -ANN -80.
Optional 4XTMF module (conventional reverse polarity/city
box transmitter).
PROGRAMMING AND SOFTWARE,
Can be programmed at the panel with no special software
or additional equipment.
Programmable Make/Break Ratio.
Upload/Download (local or remote) of program and data via
integral DACT.
USER /N'iERFACE:
Strobe Synchronization for System Sensor, Wheelock, • Built-in DACT (Digital Alarm Communicator/Transmitter).
Gentex, Faraday, or Amseco devices.
Selective Silence (horn -strobe mute).
Temporal or Steady Signal.
Silenceable or Nonsilenceable.
Optional CAC -5X Style Z (Class A) Converter Module for
NACs and IDCs (2 required for UNIMODE-10UD).
Form -C Relays for Alarm, Trouble and Supervisory - Con-
tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive).
Integral 80 -character LCD display with backlighting and
keypad.
Real-time clock/calendar with automatic daylight savings
adjustments.
ANN -BUS for connection to remote annunciators.
Audible or silent walk test capabilities.
Piezo sounder for alarm, trouble, and supervisory.
DA -60186:D7 •05/14/2009 — Page 1 of 4
Controls and Ondics$ors Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation,
Supervised, nonpower -limited.
LED INDICATORS Battery (sealed lead acid only) — J12:
FIRE ALARM (red) Maximum Charging Circuit - Normal Flat Charge: 27.6'VDC
SUPERVISORY (yellow) 0 1.4 A. Supervised, nonpower -limited.
TROUBLE (yellow) Maximum Charger Capacity: 16 AH battery for UNIMODE-
AC POWER (green) 5UD, and 26 AH battery for UNIMODE-10UD. [Two 18 Ali
ALARM SILENCED (yellow) batteries can be housed in the FACP cabinet. Larger batter
fes require separate battery box such as the BB -26 or BB -
CONTROL BUTTONS 55•]
ACKNOWLEDGE Minimum Battery Size: 7 AH.
ALARM SILENCE Initiating Device Circuits — T134 (and TB 6 on UNIMODE-
SYSTEM RESET (lamp test) 10UD only): i
DRILL Alarm Zones 1 - 5 on TB 4 (UNIMODE-5UD and UNI-
MODE-10UD).
Terminal Blocks Alarm Zones 6 - 10 on TB6 (UNIMODE-10UD only).
AC Power- TBI: Supervised and power -limited circuitry.
Operation: All zones Style B (Class B).
UNIMODE-5UD (FLPS-3 Power Supply): 120 VAC, 50/60
Normal Operating Voltage: Nominal 20 VDC. HZ, 1.00 A.
UNIMODE-101-113 (FLPS-7 power Supply): 120 VAC, 50/60 Alarm Current: 15 mA minimum.
HZ, 3.80 A. Short Circuit Current: 40 mA max.
k
Depth = 5.207" (13.23 cm)
P
Door = 16.821" (42.73 cm)
Backbox = 16.65" (42.29 cm)
Left Side
Door = 19.26" (48.92 cm)
Backbox = 19.0" (48.26 cm)
Bottom I y
Cabinet Measurements
Page 2 of 4 — DA -60186:131 •05/14/2009
Depth =
5.257"—1
13.353 cm)
N
Right Side
Maximum Loop Resistance: 100 ohms.
End -of -Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL -
listed).
Standby. Current: 2 mA.
Refer to the ADT Device Compatibility Document for listed
compatible devices.
Notification Appliance Circuits — TB5 (and TB 7 on UNI -
MODE -LOUD only):
Four NACs
Operation: Style Y (Class B)
Special Application power
Supervised and power -limited circuitry
Normal Operating Voltage: Nominal 24 VDC
Maximum Signaling Current: 3.0 A for UNIMODE-5UD,
2.5 A maximum per NAC; 7.0 A for UNIMODE-10UD, 3:0 A
maximum perNAC.
End -of -Line Resistor: 4.7K ohm, 1/2 watt (Part #71252)
Max.,Wiring Voltage Drop: 2 VDC
Refer to the ADT Device Compatibility Document for compati-
bleFlisted devices.
Form.0 Relays —TB8:
Relay, 1 (factory default programmed as Alarm Relay)
Relay 2 (factory default programmed as fail-safe Trouble
Relay)
Relay 3 (factory default programmed as Supervisory Relay)
y
Special. Application Resettable Power — T89:
Jumper selectable by. JP31 for resettable or, nonresettable
power.
Operating voltage`. 24 VDC nominal.
Maximum available current: 500 mA - appropriate for pow-
ering"four-wire smoke detectors.
Power-limited'circuit.
Refer to the ADT Device Compatibility Document for listed
compatible devices.
Remote Sync Output - TB2: Remote power supply synchro-
nization output, only required for the UNIMODE-51.11). 24 VDC
nominal'special application power. Maximum current is 40 mA.
End -of -Line Resistor: 4.7K ohm. Supervised and power -lim-
ited circuit.
Product Line Information
UNIMODE-51JID: Five -zone, 24 -volt Fire Alarm Control Panel
includes backbox, FLPS-3. power supply, technical manual,
and a:frame & post operating instruction sheet).
UNIMODE-1101,11): Ten -zone; 24 -volt Fire Alarm Control Panel
includes backbox, FLPS-7 power supply, technical manual,
and a frame & post operating instruction sheet).
OPTIONAL MODULES
GAC -5X: Optional (Class A) Converter Module. Converts Style
B.(Class B) Initiating Device Circuits to Style D (Class A); and
Style Y,(Class B) Notification Appliance Circuits to Style Z
Class A). Connects to J2 on the UNIMODE-5UD .and UNI-
MODE-IOUD main circuit board and to J7 on the UNIMODE-
10UD.
NOTE: Two Class A Converter Modules are required for the ten -
zone panel.
4XTMF: Transmitter module. Provides a supervised output for
local energy: municipal box transmitter and alarm and trouble
reverse polarity. Includes a disable switch and disable trouble
LED. A module jumper option allows the reverse polarity circuit
to open with a system trouble condition if no alarm,conditions_,
exists. Mounts to the main circuit board connectors J4, and J5:
COMPATIBLE ANNUNCIATORS
ADT -ANN -80: Remote LCD Annunciator. Mimics the informa=
tion displayed on the FACP's LCD. Red.
ADT -ANN -LED: LED Annunciator with three LEDs for each
zone: Alarm, Trouble, and Supervisory. Mounts in the DP -
51050(B) dress panel.'(Forwhite, order ADT )
ADT ANN-RLED: LED Annunciator with three alarm (red) indi-
cators for up to 30 input zones or addressable points.
ADT ANN-RLY: Relay module. Mounts inside the cabinet. Pro-
vides ten Form C relays.
ACCESSORIES
DP -51050: Optional dress, panel. Restricts access to the, sys-
tem wiring while allowing access to the membrane switch'
panel
BB -26: Battery backbox, holds up to two 25 AH batteries and
CHG-75.
BB -55: Battery backbox, holds up to two 25 AH batteries.
TR -CE: Optional trim -ring for semi -flush mounted cabinets.
ADT -PRN -6: UL listed printer.
DA -60186M1 •05/14/2009 — Page 3 of 4
SYSTEM SPECIFICATIONS
System Capacity
Annunciators......................................................................8
Electrical Specifications
UNIMODE-5UD (FLPS-3 Power Supply): 120 VAC, 60 HZ,
1.0 A
UNIMODE-10UD (FLPS-7 Power Supply): 120 VAC,
60 HZ, 3.90 A
Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula-
tion, supervised, nonpower -limited
Cabinet Specifications
Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x
0.72' (1.82 cm.) deep. Backbox: 19.00' (48.26 cm.) high x
16.65' (42.29 cm.) wide x 5.25' (13.34 cm.) deep. Trim Ring
TR -CE): 22.00' (55.88 cm.) high x 19.65' (49.91 cm.) wide.
Shipping Specifications
Dimensions:
20.00" (50.80 cm.) high
22.5" (57.15 cm.) wide
8.5' (21.59 cm_) deep.
Weight: 27 Ib (12.20 kg)
Temperature and Humidity Ranges
This system meets NFPA requirements for operation at 0 —
49°C/32 — 120°F and at a relative humidity 93% +— 2% RH
noncondensing) at 32°C t 2°C (90°F t 3°F). However, the
useful fife of the system's standby batteries and the electronic
components may be adversely affected by extreme tempera-
ture ranges and humidity. Therefore, it is recommended that
this system and its peripherals be installed in an environment
with a normal room temperature of 15 — 27°C/60 — 80°F.
Agency Listings and Approvals
The listings and approvals below apply to the basic UNIMODE-
5UD and UNIMODE-10UD control panels. In some cases, cer-
tain modules or applications may not be listed by certain
approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
UL Listed: File S232
FM Approved
CSFM: 7165-1574:204
MEA: MEA: 333-07-E
NFPA Standards
The Unimode-5UD/10UD complies with the following NFPA 72
Fire Alarm Systems requirements:
LOCAL (Automatic, Manual, Waterflow and Sprinkler
Supervisory).
AUXILIARY (Automatic, Manual and Waterflow) (requires
4XTMF).
REMOTE STATION (Automatic, Manual and Waterflow)
Where a DACT is not accepted, the alarm, trouble and
supervisory relays may be connected to UL 864 listed
transmitters. For reverse polarity signaling of alarm and
trouble, 4XTMF is required.)
PROPRIETARY (Automatic, Manual and Waterflow).
CENTRAL STATION (Automatic, Manual and Waterflow,
and Sprinkler Supervised).
System Sensor® is a registered trademark of Honeywell International Inc.
02009. All rights reserved. Unauthorized use of this document is strictly
prohibited.
This document isnot intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Made in the U.S. A.
For more information, contact ADT. Phone: (561) 988-3600, FAX: (561) 988-3675.
www.unimoae.com
Page 4 of 4 — DA -60186:131 -05/14/2009