Loading...
HomeMy WebLinkAbout1007 Willow AveRECORD COPY oaSP,. kn O • v BUILDING Sf• g11 To: Walter Jackson 2350 Pemberton St Oviedo, FL 32765 Re: Foundation Repair 1007 Willow Ave Sanford, FL 32771 BP# 18-4053 October 22, 2018 Please be aware that the Building Official requires an affidavit from the Engineer of record for the inspection for the repair of the building's foundation — specifically all work shown on Sheet A-1 of the plans. No inspections will be performed by the Building Department for this portion of the project.. When this portion of the work is complete, please provide the Building Department with a signed and sealed affidavit from the Engineer of record indicating the foundation repair has been personally inspected and complies with the provisions of the signed & sealed plans. A Final Building Inspection will not be conducted and the job will not be considered complete without this affidavit. Whenever a permit is issued in reliance upon an affidavit or whenever the work to be covered by a permit involves installation under conditions which, in the opinion of the building official, are hazardous or complex, the building official shall require that the architect or engineer who signed the affidavit or prepared the drawings or computations shall supervise such work. In addition, they shall be responsible for conformity to the permit, provide copies of inspection reports as inspections are performed, and upon completion make and file with the Building Official a written affidavit that the work has been done in conformity to the reviewed plans and with the structural provisions of the technical codes. In the event such architect or engineer is not available, the owner shall employ in his stead a competent person or agency whose qualifications are reviewed by the Building Official. The Building Official shall ensure that any person conducting inspections is qualified as a building inspector under Part III of Chapter 468, Florida Statutes. Sincerely, Steve Fiorey, CBO Deputy Building Official City of Sanford 407.688.5065 steve.fiorey@sanfordfl.gov Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, Fl- Inst #2018126192 Book:9243 Page:1298; (1 PAGES) RCD: 11/5/2018 2:19:06 PM REC FEE $10.00 THIS INg U,,M_E.NTJPnR.E_P, RED Y: . ' Name: - (X+ G! 1 V Lff Of'j wQ /-turAddress: FL NOTICE OF COMMENCEMENT State of Florida County of Seminole 75-lg1 3u --5,4 -t zo --0o9) lu Permit Number: Parcel ID Number: The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: In addition to himself, Owner Designates To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The'ixpiration date Is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in It are true to the best of my knowledge and belief. Owner's Signature Owners Printed Name Florida Statute 713.13(1)(g): "The owner must sign the notice of commencement amino one.else may be oertNttetr-In sLan In his or her stead'- - State of County of s m i Yl 0 I e The foregoing instrument was acknowledged before me this 1 1n dayofl1c+ he 1r N { by ,. V W e( 1 S i' l t I 1 I on IWho is personally known to me Name of person making statement In ( ORwhohasproducedidentificationKtypeofidentificationproduced: FLU' [ ( 3!5 W q V 45 1 ?O COBIERTT Nala FloridaCo7180 11. 2021c.r.,My C a L: czo Notary Signature y„';FORI fi • r, ram. r SEP 2 6 2018 6 PERMIT APPLICATION Application No: 18 qo,!,N) Qv el Documented Construction Value: $ vi Job Address: 1007 ^o/ it 1. ( o ,,) e, Historic District: Yes No Parcel ID: •S "- Residential Commercial Type of Work: New Addition Alteration Description of Work: City, State Zip: Demo Change of Use Move e Property Owner Information' Phone: 11-0q- G 6?'7 Resident of property?: Contractor Information Name G'1116L;pl 0 ! JL Ci , l Street: 2-26 GM n. l 10, City, State Zip:, l l,bf 12 Name: Street: City, St, Zip: Bonding Company: Address: E"hone: At)J-:7&6-A!M!b Fax State License No.: C6 C-1062CR Architect/Engineer Information Phone: Fax E-mail: _ Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name coftTllc q I io 119 Signature of Notary -State of Florida Date Owner/Agent is 4 Personally Known to Me or Produced ID Tyee of ID 44, AMANDACOBERT Notary Public - State of Florida Commission BELOW IS My Comm. Expires Dec 11.2021 Signature of Contractor/A t Date Pri Contractor/Agent's Name oil ,3P Signature of Notary -State of Florida Date Contractor/Agent is Produced ID Known to Me or NOWy PW_ " 3fe1e Ot Florida Tamara Hunter MY Commission GG 172730 11tPiree 01/04/2022 Permits Required: Building ErElectrical 2. Mechanical Plumbing KGas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Se-1 APPROVALS: ZONING: Ib I ,an' b UTILITIES: - ENGINEERING: MIC FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Sf' to • 22- • t2' COMMENTS: I s oi- wcfk Alt tr W4 rl -J-P "k4CrJvr a-L-A t i%4-a,..tas- ds S hn..., lan . 0 dJa .CFAfhi, Ke mvcxr=_cc rv, a4cmr. RR Parcel Information ff r ! x low Legal Description LOT 8 BLK 12 TR G TOWN OF SANFORD PB 1 PG 115 Taxes Property Record Card Parcel: 25-19-30-5AG-120G-0080 Property Address: 1007 WILLOW AVE SANFORD, FL 32771 Value Summary F I FPS[ M 2018 Working 2017 Certified Values Values Valuation Method E Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 20,519 17 140 Depreciated EXFT Value Land Value (Market) 10,822 m 3 $9,968 Land Value Ag r__.... W .. Just/Market Value ** 31,341 a ... .......... 27,108 Portability Adj Save Our Homes Ad/ 0 1$0 Amendment 1 Adj E $1,522 IE $0 P&G Adj 0 0 Assessed Value 29,819 27,108 Tax Amount without SOH: $516.00 2017 Tax Bill Amount $516.00 Tax Estimator a...'.....H...... Save Our Homes Savings: $0.00 TRIM Notice Help Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values I Taxable Value County General Fund $29,819 $0 $29,819 Schools $31 341 $0 $31,341 m _ _ _ _.. .... ..___.. -._ _ City Sanford $29,819 ; so, 29,819 SJWM(Saint Johns Water Management) ] $29,819 $0 1 $29,819 County Bonds $29,819 $0 $29,819 Sales Description Date Book Page Amount Qualified Vac/Imp QUIT CLAIM DEED 12/1/2011 1 07692 0187 $100 1 No Improved QUIT CLAIM DEED 10/1/2011 07646 1085 $100 No Improved QUIT CLAIM DEED 9/3/2009 07248 1625 $100 No Improvedm ADMINISTRATIVE DEED 6/1/1984 01558 10844 $5 000 No Improved Flnd Comparab9e Sales Land _ ..__ Method Frontage Depth Units Units Price Land Value FRONT FOOT & DEPTH 64.00 117.00 ( 0 $190.00 1 $10 822 Building Information Is Bed/Bath count incorrect? Click Here- 1Description Year Built Fixtures Bed Bath Base Area Total SF Living SF Et Wall Adj Value Repl Value AppendagesActual/Effective 1 1 1925 ? 31 1 10 1 774 ] 1,012 858 $20,519 $51,298 Description Area f SINGLE ( SIDING FAMILY GRADE 3 I PNORCLOSED CH 84.00 FINISHED i i SCREEN PORCH 154.00 I UNFINISHED j Permits Permit # Description Agency Amount CO Date Permit Date No Permits I I Permit data does not originate from the Seminole County Property Appraiser's office. For details or questions concerning a permit. please contact the building department of the tax district In which the property Is located. Extra Features Description Year Built Units Value New Cost No Extra Features LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: t I hereby name and appoint: an agent of Name of to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): The specific permit and application for work located at: Street Address) nn Expiration Date for This Limited Power of Attorney: 2 l ( J License Holder Name: State License Number: Signature of License H STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged befo e me this day of , 200, by who is persona ly known to me or p who has produced as identification and who did (did not) e an oath. Signature Notary Seal) Print or type name Notary Public - State of El b d do — Commission No. My Commission Expires: 40 Notary Public State of Florida Tamara Hunter Rev. 08.12) INy Commissio20n GG 172730 ar Expire, 0110 122 S, CITY Ofi i 4ORD FLORIDA City of Sanford Planning and Development Services Engineering — Floodplain Management Flood Zone Determination Request Form Name Walter D. Jackson Frim Optimum Construction, Inc. Address 2350 Pemberton St City: Oviedo Phone: 407-766-4898 Fax: State FL Property Address: 1007 Willow Avenue Property Owner: Owens Pittman Parcel Identification Number: Phone: 407-349-4807 Zip Code: 32765 Email: walterjackson@earthlink.net 25-19-30-5AG-120G-0080 Fax: Email: The reason for the flood plain determination is: New Structure X Existing Structure (Pre-2007 FIRM Adoption) Expansion/Addition 1-1 Existing Structure (Post 2007 FIRM Adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption = finished floor elevation 24" above BFE (Ordinance 4076) OFFICIAL USE ONLY Flood Zone X Base Flood Elevation N/A Datum N/A FIRM Panel Number 120294 0070F The referenced Flood Insurance Rate Map indicates the following: The Parcel is in the Floodplain A portion of the Parcel is in the Floodplain X The Parcel is not in the X Floodplain The Structure is in the Floodplain The Structure is not in the Floodplain Map Date September 28, 2007 Floodway Floodway Floodway Floodway Floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-4053 Reviewed by: 1ffwa'1n6'4, CF/L%- Michael Cash, CFM Date: 10/01/2018 T:\Engr-Files\Elevation Certificate\w\Willow Ave\1007 W Q O I of0 uil I 117.00p4_-- -- -- _ I I 2500 _ 47.00 I I Oo EXISTING 1 STORY WOOD FRAMENSTUCTURE o 4 .00 117.00 NOTE: THIS IS NOT A LEGAL SURVEY NO WORK WILL BE DONE OUTSIDE THE FOOT PRINT OF THE STRUCTURE I I I PL -- -- -- 51 E PLiIN m 1 CJ>: N ta'!aU UI I-1 or , .sums REVISIONS nn e i 117.00p4. 0 1 I 1 I W P 2500 _ 47.00 1 o wN Q o EXISTING 1 STORY WOOD FRAMENSTRUCTURE p r, cV I a LL J4 00 i O I 1 1 117.00 - PL i NOTE: THIS IS NOT A LEGAL SURVEY NO WORK WILL BE DONE OUTSIDE THE FOOT PRINT OF THE STRUCTURE U O. i of i sneers Bpff- REQUIRED INSPECTION 4053 VENG PERM.- T, i. Footer Setback Stemwall Fbundatio3i / Form Board.*Survey SlabIM-onlo S-lab-Pipour Lintel / Tie Beam / Fill Down Cell Sheathing -L Walls - Sheathing -L, Roof Roof Dry In iFrame Insulation Rough In Tirewall Screw Pattern Drywall / Sheetrock Lath Ins pe6,ti-on Final Solar Final Roof Final Stucc6. /.Siding Insulation FiRnalnal Final Utility; B-uifding- p Final Door Final Final Screen.Room Final, Pool Screen Enclosure. Home TMobileHoBuildingFinal' Pre. -Demo Final Demo. Fina-I'Single Ownffy! Residence Final. Building (Other) Addiress: N.-M. max Insgeeflon D sml2dom Electric. Underground footer /' Slab Steel Bond Electric Rough I T.U.Q. Pre -Power Final Electric Final t. gna Ing min max. Inspe6don DescrAlpflon PIU=Mb gUnderground Plumbing Sewer J[Plumbing Tubr Set Plumbing Final A.. Im I z Max limsRechom Dese Ap on Mechanical Rough Mechanical. Final Uy. rvfmm ONI =10 Max rMspection. . Des-criflom I Gas Underground - Gas Rough Final REVISED.* Jbne 2014 RECORD COPY a City of Sanford Building and Fire Prevention Product Approval Specification Form gUILD,L\ c Permit # * 4 8- 4 0 5 3 aANFDRD 41 Project Location Address FA RTU N As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hung OQU&I Um I Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding_LIP PUZA 1 00 WA qI90;-10, Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category/Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature I / j( UL&k, U . Applicant's Name Please Print) June 2014 m SIDE-SIDE -HINGED WOOD -EDGE STEEL DOOR UNITHINGED DOOR WITH / WITHOUT SIDELITES QUIERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. 3. IN THE HVHZ, FACTORY PRIMED DOORS MUST BE PAINTED IN ACCORDANCE WITH SECTION 2220 OF THE FBC. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING OF LITE FRAME MATERIAL: SELF IGNITION TEMP ASTM D1929 740 'F > 650 'F RATE OF BURNING ASTM D635 0.77 IN MIN SMOKE DENSITY ASTM D2843 13A TENSILE STRENGTH* ASTM D538 7.50% DIFF n rrc intmrv 45D0 HOURS XENON ARC METHOD 1 hdde0d: 10 NAA9Y y6'` Cefff, ' nNO: AtS61m _ 149- MAX. OVERALL FRAME WIDTH 21" MAX 36.375" MAX. D.L.O. - PANEL WIDTH 37.5" MAX. W/ASTRAGAL FRAME WIDTH c cR Nm C) J O d}' cm 11I 1N9OOR UNIT ,DOUBLE DOOR UNIT TABLE OF CONTENTS SHEET # DESCRIPTION 1 TYPICAL ELEVATIONS & GENERAL NOTES 2 ANCHORING LOCATIONS &DETAILS 3 ANCHORING LOCATIONS &DETAILS 1 . 14 IIi I WH RE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIGMAXWIDTHINWINGOUTSWIGINSWINGOUTSWINGX37.5 76.0 -7 .0 76.0 76.0 19.0 -19.0 +55.0 -55.0 XX7455.0 -55.0 55.0 55.0 19.0 -19.0 +55.0 -55.0 OXorXO75t55.0 -55.0 55.0 5 .0 19.0 -19.0 1 +55.0 -55.0 A 1 112.5 55.0 -55.0 55.0 55.0 55.0 OXXO14955.0 -55.0 55.0 5 .0 19.0 -19.0 +55.0 -55.0 KURT BALTHAZOR FLORIDA P.E. 56533 p 00 U O 10 O ' j 1=- O C Q C u j U In 7/ 11/0 N. T.S. BY. SW! er: NG NO.: MA- FLO121 L OF - 3' SEE DETA C" 3" F" Addendwn to NAM CeAifiptlonNo: NSW/t} l J/J Date k4ei'e 3- o v U a SEE DETAIL J " D" n I u1 It in fe 8 x 2-1/2" # 10 x 2" 8 x 2-1/2" 10 x 5/8" 8 x 2-1/2" #10 x 1" E!! 10 x 5/8" •• 10 x 3/4" 10 x 2' DETAIL "E" ASTRAGAL FRAME / DOOR ATTACH ASTRAGAL RET DETAIL "D" 1 1.375" T INSWING THRESHOLD AINER BOLT DETAIL "C" STRIKE PLATE TO FRAME TYPICAL AS SHOWN. 0.9621 T OUTSWING THRESHOLD EE DETAIL ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "F" ASTRAGAL IG (1/8" TEMP. GLASS) DOW 995 OPTIONAL INSERT AL R BUTYLALUM, STEEL OR Bl1M SPACERS i/2' SITE 6 x t-1/2" PHS DOW 995 El(TFRIQ RIO TYPICAL GLAZING DETAIL ay: BY: T.S. OF SEE DETAIL C" SHT. 2 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY LUIS R. LOMAS, PE FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE 10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". 2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG CORRUGATED FASTENERS LOCATED 3" FROM EACH END AND MAXIMUM 7" O.C. OR #10 X 2" FLAT HEAD WOOD SCREWS LOCATED 6" FROM EACH END AND MAXIMUM 12" O.C. 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. I Ilil Il 11 I a w a w B JJ 0o a 3'6- 6" 3" — 3' g" Addendum to NW Cei6lieamNo.: Rsdeared By: Dato ' a Lc) O C p Q O O cj: O W CD U Lc) U z HARDWARE SCHEDULE 10-00-00vG01. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND O SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. ^oco CC) 2. 4" X 4" FULL MORTISE BUTT HINGES rn N o N 0 Of ::N 1.50' 1.25" — MIN .. 0.25" MIN I o , i w 0 0 in z0.25" MAX CL SHIM SHIM DAME: 7/17/05 ar+ JCL SCALE: N.T.S. DWG. BY: SWS GHK. BY: TYPICAL WOOD BUCK TYPICAL MASONRY OBAWNG NO.; ANCHOR INSTALLATION ANCHOR INSTALLATION DWG-MA—FLO128-05 sHEET 3 OF 3 SIDE -HINGED WOOD -EDGE STEEL DOOR UNIT 8" DOUBLE DOOR WITH / WITHOUT SIDELITES a Q 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. 3. IN THE HVHZ, FACTORY PRIMED DOORS MUST BE PAINTED IN ACCORDANCE WITH SECTION 2220 OF THE FBC. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING OF LITE FRAME MATERIAL: TFST nFCraimn . SELF IGNRION TEMP D1929 740'F > 650 'F RATE OF BURNING D635 AFSTM 0.77 IN MIN SMOKE DENSITY D2843 13.4% TENSILE STRENGTH+ TM D638 7,50% DIFF 4500 HOURS XENON ARCMETHODr crt atAinttarv AddeMum to NAW wcalimNo.: ACC 6qo Rwowed By U81BRevBY TABLE OF CONTENTS SHEEP / RIPTION1TY&6 2 AN3AN&DETAILS 149" MAX. OVERALL FRAME INDTH 21" MAX 36.375" MAX. PANEL WIDTH 37.5" MAX. IN/ASTRAGAL FRAME WIDTH n ro ry Ci a OUBLE DOOR UNIT W -SIDELITES Lo pp _ 00 CS O Q 00 O f)f -j F=. ZtU O Z 4U LL) Q LiL f score: N.T.S. kDWO BY: SW: BY: KURT BALTHAZOR c NO.: FLORIDA P.E. MA-FL012E#56533 i OF , 3" SEE DETAI C" 3" 0 ccv a U a SEE DETAIL J " D" 0 w ' w 00 a G II 6" F" Addendum to NAMI BtificCuw.: Rwiol a ey. Date R9v ewe Ei 8 x 2-1/2" #10 x 2" 8 x 2-1/2" 70 x 5/8 10 x 5/8" •• 70 x 3/4" 10 x 2' DETAIL "E" ASTRAGAL FRAME / DOOR ATTACH ASTRAGAL RETAINER BOLT DETAIL " D" DETAIL " C" STRIKE PLATE TO FRAME AS SHOWN. TYPICAL 1 D.9621 1. 375" T T INSWING THRESHOLD OUTSWING THRESHOLD El LEA c 0c) 0 Lr- J F= ErLu O aU Z u U Li EE DETAIL C" 6" ASTRAGAL RETAINER BOLT HOLE aN MUST BE DRILLED THROUGH w THE THRESHOLD & INTO THE a v_viowo z STRUCTURE DEEP ENOUGH a = FOR A 1.375" THROW Do DETAIL " F" ASTRAGAL IG ( 1/6" TEMP. GLASS) INSERT DOW995 OPTIONAL BUTYL ALUM, STEEL ORR BUI'fL SPACER 1/ 2" SITE w C] U m 6 X 1-1/2" PHS DATE: 11 D, DWG. BY: SW! DOW 995 J v... hCi,A •• CHK. BY: EXTERIOR INMRIOB DRAWIHO NO.: TYPICAL GLAZING DETAIL DWG—MA—FL012E 2 OF 3. SHEET s SEE DETAIL C" SHT. 2 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY LUIS R. LOAAS, PE FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE 10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". 2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG CORRUGATED FASTENERS LOCATED 3" FROM EACH END AND MAXIMUM 7" O.C. OR #10 X 2" FLAT HEAD WOOD SCREWS LOCATED 6" FROM EACH END AND MAXIMUM 12" O.C. 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE, 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. 6" h6"3"_I I_ r 3" I - I7 3 — 1 I— 3„ o U a SEE DETAIL D" SHT. 2 w 0 O F-- 1a I I I'I 16. I I Iv I' 0w a a ti% B g a I II II -fill it j Addendum to NAkA CerMiealiarNG.:NfQr..-...- - - Ra wedBY. flats RW1i16 t s 1.50" MIN 6^ 6„ HARDWARE SCHEDULE 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES MAX SHIM TYPICAL WOOD BUCK ANCHOR INSTALLATION 1.25 n •, t ` M25" SHIM CL TYPICAL MASONRY ANCHOR INSTALLATION SCALE: N.T.S. M. BY: SWS CHK. BY: ORAWANG NO.: OF INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN, UNLESS OTHERWISE STATED. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF GUSSET INSTALLATION NOTES: ANCHORS TO BE USED FOR PRODUCT INSTALLATION. ANDERSEN CORPORATION rM1UCIJCII 100 SERIES W1.00wg•ooea, SINGLE HUNG WINDOW 100FOURTH AVE NNORTH BAYPORT, MN 550034M PH: (651)2fi4-5150 FX: (651)2fi4-54B5 1. FOR INSTALLATION TO 2X WOOD BUCK, USE TWO (2) #12 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 31/2 INCH OF WOOD SCREWS PER GUSSET. INSTALLATION SHALL THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (I.E., WITHOUT MAINTAIN THE FOLLOWING REQUIREMENTS: CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE A. MINIMUM EMBEDMENT OF II/2" INSTALLATION ANCHOR TO THE NEXT. B. MINIMUM EDGE DISTANCE OF 3/4" 4. THROUGH FRAME/INSTALLATION CLIP: FOR INSTALLATION INTO 2X WOOD FRAME USE TWO (2) #8 WOOD SCREWS PER INSTALLATION CLIP OR ONE (1) #8 WOOD SCREW THROUGH FRAME PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. S. THROUGH FRAME/INSTALLATION CLIP: FOR INSTALLATION THROUGH 1X BUCK TO CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETE/ MASONRY, USE ONE (1) 3116 INCH ITW TAPCON THROUGH FRAME PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1 1141NCH MINIMUM EMBEDMENT OR ONE (1) OF THE FOLLOWING THROUGH EACH INSTALLATION CLIP: 5.1. 3116 INCH ELCO CRETE-FLEX S54 THROUGH INSTALLATION CLIP PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1114 INCH MINIMUM EMBEDMENT. 5.2. 114 INCH ELCO AGGRE-GATOR THROUGH INSTALLATION CLIP PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1 3141NCH MINIMUM EMBEDMENT. 5.3. 1141NCH HILTI KWIK-CONII THROUGH INSTALLATION CLIP PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1 314 INCH MINIMUM EMBEDMENT. 5.4. 1141NCH POWERS TAPPER THROUGH INSTALLATION CLIP PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1 314 INCH MINIMUM EMBEDMENT, 6. THROUGH FRAME/INSTALLATION CLIP: FOR INSTALLATION THROUGH METAL STUD USE TWO (2) #8 SELF -TAPPING SCREWS PER INSTALLATION CLIP OR ONE (1) #8 SELF TAPPING SCREW THROUGH FRAME PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL STRUCTURE. 7. NAILING FIN: FOR INSTALLATION THROUGH 2X WOOD FRAME USE ONE (1) #8 WOOD SCREW R 8D COMMON NAIL PER LOCATION OF SUFFICIENT LENGTH TO ACHIEVE 1 1121NCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. 8, NAILING FIN: FOR INSTALLATION THROUGH METAL STUD USE ONE (1) #8 SELF -TAPPING SCREW OF SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM PENETRATION BEYOND METAL STRUCTURE, 9. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. IO.INSTAILATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 11.FOR GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 12ANSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 13.INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90. MIN. COMPRESSIVE STRENGTH OF 2500 PSI. D. STEEL - MINIMUM YIELD STRENGTH OF 33 KSI. MINIMUM WALL THICKNESS OF 33 MILS, (20 GUAGE) E. ALUMINUM - 1/8" MINIMUM THICKNESS (6063-T5). 2. FOR INSTALLATION TO METAL SUBSTRATES, USE TWO (2) 1/4-20 TEK SCREWS PER GUSSET. INSTALLATION SHALL MAINTAIN THE FOLLOWING REQUIREMENTS: A. MINIMUM PENETRATION OF 3 THREADS BEYOND METAL STRUCTURE B. MINIMUM EDGE DISTANCE OF 1/2" 3. FOR INSTALLATION INTO CONCRETE/MASONRY SUBSTRATES, PLEASE REFER TO SHEET 1, INSTALLATION NOTE S. ANCHORS SHALL FOLLOW SAME SPECIFICATIONS AS OUTLINED FOR INSTALLATION CLIPS. GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 2010 FLORIDA BUILDING CODE(FBQ, 2009 INTERNATIONAL BUILDING CODE ANDTHE 2009 INTERNATIONAL RESIDENTIAL CODE, EXCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: AAMA/WDMA/CSA 101/I.S.2/A440-05/08 AAMA 450-10 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X AND METAL STUD FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3, 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE, BUCK DESIGN AND INSTALLATION ISTHE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED TO PROTECT THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: FIBREX®. 7. GLASS MEETS THE REQUIREMENTS OF ASTM E1300-04 GLASS CHARTS. SEE SHEET 6 FOR GLAZING DETAILS. 8. DESIGNATIONS "X"ANO"0" STAND FOR THE FOLLOWING: X: OPERABLE PANEL 0: FIXED PANEL 9. CUSTOM SIZES AVAILABLE UPON REQUEST. TABLE OF CONTENTS SHEET REV15ION SHEET DESCRIPTION 1 A GENERAL & INSTALLATION NOTES 2 A ELEVATIONS 3 A ELEVATIONS & ANCHOR LAYOUTS 4 A THROUGH FRAME/INSTALLATION CLIP ANCHOR LAYOUTS 5 A VERTICAL SECTIONS 6 A HORIZONTAL SECTIONS & GLAZING DETAIL 7 A COMPONENTS & BILL OF MATERIALS 8 A MULLION OP CHART I & DETAILS 9 A MULLION OP CHART 2 UNIT# SIZE & CONFIGURATION DESIGN PRESSURE MISSILE IMPACT RATING I O/X) 47 1/2" X 77 1/2" 30 PSF NON -IMPACT 2 O/X) 41 1/2" X 95" 30 PSF NON -IMPACT 3 O/X) 47 1/2" X 89 1/2" 30 PSF NON -IMPACT 4 O/O/X) 47 1/2" X 95 1/2" 30 PSF NON -IMPACT 5 O/X.O,O/X) 143 1/2" X 71 1/2" 30 P5F NON -IMPACT NOTE'. 1. SEE SHEETS 8 & 9 FOR MULLION DP CHART, ASSEMBLY & INSTALLATION DETAILS FOR UNIT -TO -UNIT FIBERGLASS MULLIONS. Digitally signed by Hermes F Norero, P.E. Reason: I am approving this document Date: 2012.08.23 17:47:52-04'00' U.: H N m V) CO Z _jV) io 3 _ V) NG #: A W0029 iHEET: 1 OF 9 UNIT MAX. WIDTH 47 1/2" 01.0 MAX. WIDTH 41 1/8" 11 7D E 5 5 Gow F D.L.O. MAX. HEIGHT UNIT 34 5/8" MAX. 5 HEIGHT 771/2" OPERABLE 6 6 SASH MAX. HEIGHT 38 1/4" UNIT MAX. WIDTH 471/2" D.L.O MAX. WIDTH 41 1/4" D E 5 5 D.L.O. MAX. lieI HEIGHT 6 17 1/4" UNIT MAX. Ga. F "O" SASH MAX. HEIGHT 6 6 c HEIGHT UNIT 95 1/2" 5 35 7/8" MAX. HEIGH' 89 1/2' Fon G 6 6 OPERABLE 5J SASH MAX. WIDTH 44 3/4" SASH MAX. WIDTH 45 5/8" ELEVATION ELEVATION UNIT MAX. WIDTH 47 1/2" ri rveTinti AAX. HT 16" UNIT MAX. WIDTH 143 1/2" UNIT MAX. WIDTH 143 1/2" SASH MAX. D.L.O. MAX. UNIT MAX. 5 5 WIDTH 69 3/4" WIDTH 41 1/4" — WIDTH 47 1/2" D E 5 5 G"„ F D.L.O. MAX. UNIT b b O O HEIGHT Ga, F D.L.O. MAX. MAX. 5 551/16" 6 b "O" "O" "p" HEIGHT HEIGHT "O" SASH MAX. UNIT 5 31 1/2" 711/2" H HEIGHT MAX. 6 „ X" 69 3/4" HEIGHT F«. G 711/2" H b 6 SASH MAX. X. HEIGHT L-7— — I b b B A 5 5 D.L.O. Max. snsH MAX. ELEVATION B WIDTH 65 1/4" WIDTH 44 3/4', 5 ELEVATION NOTE: QUALIFIES TWIN UNITS OF EQUIVALENT OR LESSER PANEL DIMENSIONS wleoows•000Ra. 100 FOURTH AVE N NORTH a YPORT. MN 55003-1096 PH; (651) 264 5150 M (651) 264-5485 mm 4 U7itp $ Z. O=a LL S LuIx j m m e V) Q Q Z N P g w HoZ M d mwo n. 1J N F' N Q O w Z H o u7 :E j a Lu w v a v LL 0 0 N LL N T Z V Y LLi Q F- i 3:E __ Z o v AW002! IEET: 2 OF 9 UNIT MAX. WIDTH 41 1/2" 01.0 MAX. WIDTH 38" D E 5 5 Gw F DLO. MAX. HEIGHT C 41 1/2" UNIT 5 MAX. HEIGHT 77112" rF--Y G ELEVATION ARCH TOP 4.0" FROM CORNER (TYP.) 4.0" FROM CORNER (TYP.) UNIT MAX. WIDTH 143 1/2" PANEL MAX. WIDTH 71 3/4" D E 5 5 UNIT MAX. H HEIGHT "O" "O" 6 23 1/2" T a FI FVATInN I I%AIYJVIVI NOTE: QUALIFIES ALL TRANSOM CONFIGURATIONS OF EQUAL OR LESSER FIXED PANEL DIMENSIONS INSTALLATION CLIP AT END OF EACH INSTALLATION CLIP AT INTEGRAL MULLION MIDSPAN FOR UNITS WIDER THAN 10' On n01. n0" INSTALLATION CLIP AT / ^ " / 3.5" FROM WIDDE ERTHAN10' AT END OF EACH INTEGRAL MULLION L 3. 5" MAX. O.C. TYP.) 3. 5" FROM ALL r CORNERS (TYP.) 3.5" MAX. O.C. (TYP.) ANCHOR LAYOUT — NAIL FIN APPLIES TO ALL CONFIGURATIONS I UN; MA HEIC- 95 UNIT MAX. WIDTH 41 1/2" 01.0 MAX. __I] WIDTH 38" ELEVATION ARCH TOP ilul wlaoows- 000as 100 FOURTH AVE N NORTH BAYPORT. MN 55003-1096 PH: (651) 264-5150 FX:(651)264-5485 w m 3 m g _ Z0 nCUIm P M O = L NZ cc 10 WV w AAX. Lu w m Z < m HT cZH42 < m 0 0 o , S a HOQ 1IJ dmLLJ10gF W d F M N N. O AAX. HTm 16" NOTE: 1. ALL MULLED UNITS SHOWN ARE INTEGRAL MULLED UNITS. 2. FOR UNIT -TO -UNIT MULLING OPTIONS AND INSTALLATION REFER TO SHEETS 8 & 9. ANCHOR SCHEDULE HEAD/SILL TAMS O.C. CORNER INSTALLATION QTY PER SUBSTRATE ANCHOR TYPE EMBEDMENT EDGE DISTANCE O.C. DISTANCE DISTANCE TYPE LOCATION IN.) IN.) DISTANCE IN.) IN.) NAIL FIN 1 WOOD 8 WOOD ANCHOR 1.50 0.75 3.50 3.50 3.50 NAIL FIN 1 WOOD 8D COMMON NAIL 1.50 0.75 3.50 3.50 3.50 NAIL FIN I METAL 08 SELF - TAPPING SCREW 3 THREADS N/A 3.50 3.50 3.50 STUD v / LU Z c zo u7 W lY w co Q co u- 0 N On ..... LL ~ ` y cohmZ J30 Y LL. < ) 3 0 i* U T. Z 1WG #: AW0029 HEET: 3 OF 9 NOTE: 1. ALL MULLED UNITS SHOWN ARE INTEGRAL MULLED UNITS. 2. FOR UNIT -TO -UNIT MULLING OPTIONS AND INSTALLATION REFER TO SHEETS 8 & 9. 4.0" FROM CORNER (TYP.) 3.5" FROM CORNER (TYP.) 3.5" FROM CORNER (TYP.) r 4.0" FROM CORNER (TYP.) 3.5" FROM O" ( CORNER (TYP.) 4.0" FROM r1 CORNER(TYP.) 1.5"(TYPJ J W. I r 1.0" (TYP.) 3.5" FROM CORNER (TYP.) 'T} 4.0" FROM 7F- -T X 3.5" FROM CORNER (TYP.) CORNER (TYP.) ANCHOR LAYOUT I THROUGH FRAME/ J- INSTALLATION CLIP 4.0" FROM ANCHOR LAYOUTCORNER (TYP.) THROUGH FRAME/ INSTALLATION CLIP AT INSTALLATION CLIP MID5PAN FOR UNITS WIDER THAN 10' INSTALLATION CLIP AT END 3.5" FROMOFEACHINTEGRALMULLIONIrCORNER (TYP.) 4.0" FROM CORNER (TYP.) 0 1 i" (TYP.) J r 1.0" T 4.0" FROM J / CORNER (TYP.) INSTALLATION CLIP AT MIDSPAN J FOR UNITS WIDER THAN 10' ANCHOR LAYOUT THROUGH FRAME/ INSTALLATION CLIP TYPJ 3.5" FROM r CORNER (TYP.) 4.0" FROM j CORNER (TYP.) 1 1.0" (TYP.) 1.5" (TYP.) 3.5" FROM CORNER (TYP.) 4.0" FROM CORNER (TYP.) ANCHOR LAYOUT THROUGH FRAME/ INSTALLATION CLIP INSTALLATION CLIP AT END OF EACH INTEGRAL MULLION L 4.0" FROM CORNER (TYP.) 1.5" (TYP.) - 3.5" FROM CORNER (TYP.) L 4.0" FROM r INSTALLATION CLIP AT END CORNER (TYP.) OF EACH INTEGRAL MULLION i fflllmlllmll 3.5" FROM SCORNER (TYP.) TYPJ 3.5" FROM CORNER (TYP.) INSTALLATION CLIP AT END OF EACH INTEGRAL MULLION ANCHOR LAYOUT THROUGH FRAME/ INSTALLATION CLIP NOTE: 1) APPLIES TO TWIN UNITS OF EQUIVALENT OR LESSER PANEL DIMENSIONS. 2) INSTALLATION CLIPS AT EACH END OF MULL ARE EXCLUDED FOR TWIN UNITS 47-1/2" & NARROWER. W INDOWS•DOORB 100 FOURTH AVE N NORTH BAYPORT, MN 55003-1096 PH: (651) 2264-5150 FX: (651) 264-5485 G M TT O ZOH Uik yy 3 Q F N N a5 vim J ixx OI Q S m N N mWOfZQQZHV) LL 8 = ~ Q < a o a a AW002 4EET: 4 OF C CAULK BETWEEN CONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS CONCRETE/ MASONRY BY OTHERS — 2X WOOD BUCK BY OTHERS CAULK BETWEEN — FIN & 2X WOOD BUCK EXTERIOR FINISH BY OTHERS O.A. WINDOW HEIGHT EXTERIOR 1 EXTERIOR O.A. WINDOW HEIGHT PERIMETER CAULK BY OTHERS EXTERIOR FINISH BY OTHERS CAULK BETWEEN FIN & 2X WOOD BUCK 8 WOOD SCREW OR 81) COMMON NAIL INSTALLATION ANCHOR CONCRETE/MASONRY BY OTHERS 1 1/2" MIN. EMBEDMENT CONCRETE/ MASONRY BY OTHERS 8 WOOD SCREW OR 81) CAULK BETWEEN COMMON NAIL INSTALLATION CONCRETE/ MASONRY & IX ANCHOR WOOD BUCK BY OTHERS 1X WOOD BUCK 3/4" MIN. BY OTHERS EDGE DISTANCE CAULK BETWEEN FIN & IX WOOD BUCK EXTERIOR FINISH BY OTHERS 1/4" MAX. SHIM SPACE INTERIOR SEE GLAZING EXTEI DETAILI 5 VERTICAL SECTION HEAD -zNWOOD FRAME NAIL FIN VERTICAL SECTION 5 MEETING RAIL SEE GLAZING DETAIL INTERIOR 1/4" MAX. SHIM SPACE MIN. EDGE DISTANCE 2X WOOD BUCK BY OTHERS CAULK BETWEEN CONCRETE/ MASONRY & 2X 1 1/2" MIN. WOOD BUCK BY OTHERS EMBEDMENT VERTICAL SECTION 5 SILL - 2X WOOD FRAME NAIL FIN O.A. WINDOW HEIGHT 2 EXTERIOR JR CONCRETE/MASONRY INSTALLATION ANCHORS. SEE INSTALLATION NOTE 5, SHEET 1. 2 1/2'. MIN. EDGE DISTANCE MIN. EMBEDMENT 1. 1/4" MAX. SHIM SPACE 1-3/4" MAX. DISTANCE FROM FRAME INTERIOR v C SEE GLAZING DETAIL VERTICAL SECTION 5 HEAD - 1X WOOD/CONCRETE/MASONRY INSTALLATION CLIP EXTERIOR SEE GLAZING I NTERIORDETAIL1 4 O.A. WINDOW 1 1-3/4" MAX. HEIGHT 2 \ DISTANCE FROM FRAME 1/4" MAX. SHIM SPACE MIN. EMBEDMENT PERIMETER CAULK — I....., BY OTHERS PRECAST SILL CONCRETE/MASONRY BY OTHERS INSTALLATION ANCHORS. SEE INSTALLATION NOTE 5, SHEET 1. 2 112" MIN. EDGE DISTANCE A) VERTICAL SECTION SILL-CONCRETE/MASONRY INSTALLATION CLIP wlnoo ws-000na 100 FOURTH AVE N NORTH 6AYPORT, MN 55003-1096 PH:(651) 264.5150 FX:(651)264-5485 mn i; o Z#$ & Z SZZ M mNo w 0M[2 xLL n awu m N i m W Q Z a LuC m it d m WF N N a LuJ Zca H z :3 j a Lu w v ix a vmLL 0 N T z xLL el 0 3f Vz 0 AlG #: AW0029 AEET: 5 OF 9 1/4" MAX. 1/4" MAX. SHIM SPACE SHIM SPACE CONCRETE/MASONRY INSTALLATION ANCHORS. SEE INSTALLATION NOTE 5, METAL STUD FRAMING SHEET 1. BY OTHERS 8 SELF -TAPPING SCREW 1 INTERIOR INSTALLATION ANCHOR 3 SEE GLAZING INTERIOR 3 1 DETAIL 1 3 THREADS BEYOND MET,ALISTRUCTURE 1 L= ON SHEATHING BY OTHERS CAULK BETWEEN FIN d SHEATHING 2 4 EXTERIOR FINISH EXTERIOR BY OTHERS PERIMETER CAULK O.A. BY OTHERS WINDOW — WIDTH HORIZONTAL SECTION 6 JAMB - METAL STUD FRAME NAIL FIN 3/4" O.A. INSULATED GLA55 EXTERIOR INTERIOR E GLAZING DETAIL 1 EXTERIOR TERIOR 4ZING 1 VERTICAL SECTION A 6 INTEGRAL MULLION POST 1/2" MIN. GLASS kBITE SILICONE BACK BEDDING GLAZING DETAIL 1 NOTE: GLA55 THICKNESS AND TYPE MAY VARY PER ASTM E 1300-04 GLASS CHART REQUIREMENTS MIN. EMBEDMENT CONCRETE/ MASONRY BY OTHERS d. IX WOOD BUCK BY OTHERS CAULK BETWEEN CONCRETE/ MASONRY S IX WOOD BUCK BY OTHERS 2 112" MIN. EDGE DISTANCE EXTERIOR FINISH O.A. BY OTHERS WINDOW PERIMETER CAULK WIDTH BY OTHERS G HORIZONTAL SECTION 6 JAMB - 1X WOOD/CONCRETE/MASONRY THROUGH FRAME INTERIOR HORIZONTAL SECTION 6 INTEGRAL MULLION POST SEE GLAZING DETAIL 1 L w eoowa•000aa 100 FOURTH AVE N NORTH BAYPORT, AN 55003-1096 PH: (651)264.5150 FX'.(651)264-5495 m 3 e V U # p Z O< ~> g J MFV) m a<_ t`p ma zH N mNa v11icZ w<Z g= e 7 o cL aco JLJ1— N o n w Z O H J u f 1 W w V co 0 Ei N N T 0 0 3 i = 2 v Z O p U N DWG #: AW0029 SHEET: O FRAME FIBREX 3.240" 1. 71 3.250" OFIXED SASH STILE FIBREX 1.240" 2.230" 3OOPERABLE SASH STILE O GLAZING BEAD FIBREX 4 FIBREX 1.420" 1.750" OOPERRABLEEX SASH END CLIP 2.098" 0.459" OINSTALLATION CLIP9304SS 4.962" a o o 00 1.500" o 0 00 0.894" 0.287" OFIXED SASH MEETING RAIL FIBREX 2.160" 1.420" 10 MULLION STIFFENER ALUMINIUM 6063-T5 1.000" 2.500" BILL OF MATERIAL NO. PART NUMBER DESCRIPTION MATERIAL MANUFACTURER 1 FRAME FIBREX ANDERSEN 2 FIXED SASH STILE FIBREX ANDERSEN 3 OPERABLE SASH STILE FIBREX ANDERSEN 4 GLAZING BEAD FIBREX ANDERSEN 5 OPERABLE SASH END CLIP FIBREX ANDERSEN 6 FIXED SASH MEETING RAIL FIBREX ANDERSEN 7 FIXED SASH REINFORCEMENT GALVANIZED STEEL ANDERSEN 8 INTEGRAL MULLION FIBREX ANDERSEN 9 INSTALLATION CLIP STAINLESS STEEL ANDERSEN 10 MULLION STIFFENER AL. 6063-T5 ANDERSEN 11 FIBGERGLASS MULLION FIBERGLASS ANDERSEN 12 MULLION TRIM VINYL ANDERSEN 13 MULLION GUSSET PLATE GALV. STEEL ANDERSEN El OFIXED SASH REINFORCEMENT GALVANIZED STEEL 1.210" 1.023" 11 FIBERGLASS MULLION FIBERGLASS 3.250" 0.500" 0.031"J 13 FIBERGLASS MULLION GUSSET PLATE GALV.STEEL 1.387" " 10.500" 1.250" 0 0 0 0 1.750" 1.125" 0 0 0 0 0 8.500" OINTEGRAL MULLION8 FIBREX 12 MULLION TRIM VINYL 1.391" POT REF 0.433" POT REF V. rquu WIMUDW> -DDDMS 100 FOURTH AVE N NORTH RAYPORT, MN 55003-M6 PH: (651) 264-5150 M (651) 264-5485 m m M T O V q $ Z Z ~ > M a 3 r o= x N Z < < = LL h 2LL m c rw-1 0 m Z<m N V m lL _ Q Z g _ d m u o ui m a m F- N Qp .O 0. N T J ^. m Vi m Z J V) j d 3* 2 2 u Z O 'o u iWG #: AWD029 HEET: 7 OF 9 y MULLION DP CHART 1 SPAN IN.) W IN.) NAILING FLANGE UNITS INTO WOOD OR METALSTUD FLANGELESS UNITS INTO WOOD OR METALSTUD FLANGELESS UNITS INTO CONCRETE/ MASONRY Allowable Design Pressure Allowable Design Pressure Allowable Design Pressure 36.0 40.0 40.0 40.0 40.0 40.0 40.0 48.0 40.0 40.0 40.0 40.0 35.6 35.6 60.0 52.0 40.0 40.0 40.0 40.0 32.9 32.9 56.0 40.0 40.0 40.0 40.0 30.5 30.5 60.0 40.0 40.0 40.0 40.0 28.5 28.5 36.0 40.0 40.0 40.0 40.0 40.0 40.0 48.0 40.0 40.0 40.0 40.0 32.4 32A 66.0 52.0 40.0 40.0 40.0 40.0 29.9 29.9 56.0 40.0 40.0 40.0 40.0 27.7 27.7 60.01 40.0 40.0 40.0 40.0 25.9 25.9 30.0 40.0 40.0 40.0 40.0 40.0 40.0 36.0 40.0 40.0 40.0 40.0 39.6 39.6 48.0 40.0 40.0 40.0 40.0 29.7 29.7 72.0 5 l) 40.0 40.0 40.0 40.0 27.4 27.4 56.0 40.0 40.0 40.0 40.0 25.4 25.4 60.0 40.0 40.0 40.0 40.0 23.7 23.7 30.0 40.0 40.0 40.0 40.0 40.0 40.0 36.0 40.0 40.0 40.0 40.0 36.5 36.5 48.0 40.0 40.0 40.0 40.0 27.4 27.4 78.0 52.0 38.3 40.0 1 38.3 38.3 25.3 25.3 56.0 37.0 40.0 1 37.0 37.0 23.5 23.5 60.0 36.0 40.0 36.0 36.0 21.9 21.9 30.0 40.0 40.0 40.0 40.0 40.0 40.0 36.0 40.0 40.0 40.0 40.0 33.9 33.9 48.0 36.0 40.0 36.0 36.0 25.4 25.4 0 52.0 34.4 40.0 34.4 34.4 23.5 23.5 56.0 33.1 38.6 33.1 33.1 21.8 21.8 60.0 32.0 37.3 32.0 32.0 20.3 20.3 24.0 40.0 40.0 40.0 40.0 40.0 40.0 30.0 40.0 1 40.0 40.0 40.0 38.0 38.0 36.0 40.0 40.0 1 40.0 40.0 31.6 31.6 90.0 48.0 32.7 38.2 32.7 32.7 23.7 23.7 52.0 31.2 36.3 31.2 31.2 21.9 21.9 56.0 29.9 34.8 29.9 29.9 20.3 20.3 60.0 28.8 33.6 28.8 28.8 19.0 19.0 24.0 40.0 40.0 40.0 40.0 40.0 40.0 30.0 40.0 40.0 40.0 40.0 35.6 35.6 36.0 36. I40.0 36.9 36.9 29.7 29.7 96.0 48.0 30.0 1 35.0 1 30.0 30.0 22.3 22.3 52.0 28.1 32.8 28.1 28.5 20.5 20.5 51.0 26.6 31.0 26.6 27.2 19A 19.1 60.0 25.3 29.5 25.3 26.2 17.8 17.8 NOTE: 1) MULLION CHART 1 APPLIES TO ANY COMBINATION OF 100 SERIES UNIT -TO -UNIT FIBERGLASS MULLION ASSEMBLIES OF SINGLE HUNG / GLIDING WINDOW / CASEMENT / AWNING / PICTURE WINDOW FRAME TYPES IN TYP. COMBINATIONS AS SHOWN IN ELEVATIONS A & B. 2) DESIGN PRESSURES ARE READ IN PSF. 3) DESIGN PRESSURE OF ASSEMBLY IS LIMITED TO THE LESSER DESIGN PRESSURE OF THE FIBERGLASS MULLION OR THE INDIVIDUAL WINDOW UNIT OF INSTALLATION. 4) MAXIMUM MULL SPAN OF 8 FT. MAXIMUM ASSEMBLY SIZE OF IT X 8' OR 8' X 12% 5) 1-WAY (RIBBON OR STACK) MULL ASSEMBLIES ONLY. ASSEMBLIES MAY BE UP TO 6 UNITS WIDE OR 6 UNITS HIGH. 6) GUSSET PLATES SHALL BE USED AT EACH END OF MULLION AND ATTACHED TO ADJACENT WINDOW UNITS WITH A TOTAL OF TWELVE (12) #8 X 1" PH SCREWS PER GUSSET PLATE. 7) INSTALLATION OF GUSSET TO THE ROUGH OPENING SHALL FOLLOW ANCHOR REQUIREMENTS SET FORTH FOR INSTALLATION CLIPS, SEE GUSSET INSTALLATION DETAIL, K/8. 8 SELF -TAPPING SCREWS ALTERNATING, 10" O.C. MAX. SEE GLAZING DETAIL I. TWO BEADS OF SILICONE USED TO SEAL EXTERIOR PVC CAP ORIZONTAL SECTION MULLION ASSEMBLY TYP. Tnwrei I Ar nNl ANCHORS, SEE GUSSET I NOTES, SHEET 1. K ISOMETRIC VIEW 8 GUSSET INSTALLATION, TYP. DISTANCE W SPAN Imo_ „A" ONyl _ „B"B.' ELEVATION A TRIBUTARY WIDTH = W = (A+8)/2 W I A„ i_ „S" -.i ELEVATION B TRIBUTARY WIDTH = W = (A+8)/2 UNIT - TO -UNIT MULL OF INTEGRAL MULL UNITS w noows•000ns IM FOURTH AVE N NMR BAYPCQT, MN 55003-10 PH:( 651)264-5150 M(651)264-5485 m yl M T O Z# $ HyZ p ~ > M Y S ^ d m J a LL 2 n uj LL w j w O m H 0 hZZ Z D pp pL H'O J O j d co u G LU CL- m x LUDl F- (V 10 10 .o w Z _ j O F- H J LL W W V fi43 v mO O N LL k j N_ cmm N 0 Z J N 00 3 UZ zRo • MULLION DP CHART 2 Andersen. NOTE: 1) MULLION CHART 2 ONLY APPLIES TO 300 SERIES UNIT -TO -UNIT FIBERGLASS MULLION r- SPAN ASSEMBLIES OF SINGLE HUNG WINDOW FRAME TYPES MULLED TO PICTURE WINDOW FRAME TYPES, IN TYP. COMBINATIONS AS SHOWN IN ELEVATIONS C, D, & E. WINDOWS -DOORS 2) DESIGN PRESSURES ARE READ IN PSF. yri IBAFOURTH 5 NNORTH3) DESIGN PRESSURE OF ASSEMBLY IS LIMITED TO THE LESSER DESIGN PRESSURE OF THE "A' BAYPORT, MN 55003-1096 FIBERGLASS MULLION OR THE INDIVIDUAL WINDOW UNIT OF INSTALLATION. PH: 16111264"5I50 FX. (651) 264 5485 4) MAXIMUM MULL SPAN OF 8 FT. MAXIMUM ASSEMBLY SIZE OF 12' X 8' OR 8' X 12'. m S) 1-WAY (RIBBON OR STACK) MULL ASSEMBLIES ONLY. ASSEMBLIES MAY BE UP TO 6 UNITS W WIDE OR 6 UNITS HIGH. 3 u # S 6) GUSSET PLATES SHALL BE USED AT EACH END OF MULLION AND ATTACHED TO ADJACENT p HZ4 0 g WINDOW UNITS WITH A TOTAL OF TWELVE (22) #8 X 1" PH SCREWS PER GUSSET PLATE. m m 7) INSTALLATION OF GUSSET TO THE ROUGH OPENING SHALL FOLLOW ANCHOR REQUIREMENTS \' 3 - O SET FORTH FOR INSTALLATION CLIPS, SEE GUSSET INSTALLATION DETAIL, K/8. `h ,= a M < vIL_ Z 't ma\\ u) ti oc m N H ulm < N 0 < H liJ 8 Li G gy`, Q F ot 05, ELEVATION C TRIBUTARY WIDTH = W = (A+8)/2 O SPAN m Z A.. O w > IL LU N VW pp 4 coVAUL"B" SPAN O N Z Q ELEVATION D - ELEVATION E r TRIBUTARY WIDTH = W = (A•9)/2 TRIBUTARY WIDTH = W = (A+B)/2 H UNIT -TO -UNIT MULL OF INTEGRAL MULL UNITS . iy 77j •( P `` N T N 00 N on Z J OB LJ 6 3 f V= (Vj) Z DWG #: AW0029 SHEET: 9 OF 9 NAILLu Lu co I SPAN IN) W IN) NG FLANGE UNITS INTO WOOD OR METAL STUD FLANGELESS UNITS INTO WOOD OR METAL STUD FLANGELESS UNITS INTO CONCRETE/ MASONRY Allowable Design Pressure Allowable Design Pressure Allowable Design Pressure 36.0 40.0 40.0 40.0 40.0 40.0 40.0 48.0 40.0 40.0 40.0 40.0 35.6 35.6 60.0 62.0 40.0 40.0 qp,0 40.0 32.9 32.9 56.0 40.0 40.0 40.0 40.0 30.5 30.5 60.0 40.0 40.0 40.0 40.0 28.6 28.6 36.0 40.0 40.0 q0.0 40.0 40.0 40.0 48.0 40.0 40.0 q0.0 40.0 32.4 32.4 66.0 52.0 40.0 40.0 q0.0 40.0 29.9 29.9 66.0 40.0 40.0 40.0 40.0 27.7 27.7 60.0 40.0 40.0 qp,0 40.0 26.9 25.9 30.0 40.0 40.0 40.0 40.0 40.0 40.0 36.0 40.0 40.0 40.0 40.0 39.6 39.6 48.0 40.0 40.0 40.0 40.0 29.7 29.7 72.0 62.0 40.0 40.0 40.0 40.0 27.4 27.4 66.0 40.0 40.0 40.0 40.0 25.4 26.4 60.0 40.0 40.0 40.0 40.0 23.7 23.7 30.0 40.0 40.0 q0,0 40.0 40.0 40.0 36.0 40.0 40.0 40.0 40.0 36.6 36.5 48.0 40.0 40.0 40.0 40.0 27.4 27.4 78.0 52.0 40.0 40.0 q0.0 40.0 26.3 25.3 56.0 40.0 40.0 3g,g 3g,g 23.6 23.5 60.0 40.0 40.0 37.3 37.3 21.9 21,9 30.0 40.0 40.0 40.0 40.0 40.0 40.0 36.0 40.0 40.0 40.0 40.0 33.9 33.9 48.0 40.0 40.0 q0,0 40.0 26.4 25.4 84.0 52.0 39.a 40.0 3g,g 3g,g 23.6 23.5 66.0 37.9 40.0 37.1 37.1 21.8 21.8 60.0 36.7 40.0 34.6 34.6 20.3 20.3 24.0 40.0 40.0 40.0 40.0 40.0 40.0 30.0 40.0 40.0 40.0 40.0 38.0 38.0 36.0 40.0 40.0 40.0 40.0 31.6 31.6 90.0 48.0 37.5 40.0 40.0 40.0 23.7 23.7 62.0 35.7 40.0 37.3 37.3 21.9 21.9 56.0 34.2 39.9 34.6 34.6 20.3 20.3 60.0 33.0 38.6 32.3 32.3 19.0 19.0 24.0 40.0 40.0 qp,0 40.0 40.0 40.0 30.0 40.0 40.0 40.0 40.0 35.6 36.6 36.0 40.0 40.0 40.0 40.0 29.7 29.7 96.0 48.0 34.4 40.0 35.3 37.8 52.0 32.6 38.1 33,2 3q,g 66.031.236.4 31.6 32.4 426, 60.030.035.030.0 30.3 2 SMARTSIOE" BAIL NG PRaaucTS TRIM & SIDING At the time of manufacture, siding meets or exceeds the per- formance standards set forth in ICC-ES-AC321 and has achieved code recognition under ESR-1301, CCNC 11826, APA recognition under PR-N124, and HUD recognition under HUD-MR-1318. For copies of ESR-1301, call LP Customer Support at 1-800-648-6893 or go online at http://www.ice-es.org/reports/pdf_files/ICC-ES/t ESR-1301.pdf or http://www.apawood.org. Precision Series panel siding with SILVERTECH or SMARTFINISH is specifically for sheds and other outdoor structures where the interior wall cavities will remain permanently exposed. Minimum 6 in. clearance must be maintained between siding and finish grade. Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 in. mm above any surface. Minimum 1 in. clearance at intersection with roof line Apply siding in a manner that prevents moisture intrusion and water buildup. All exposed wood substrate must be sealed in a manner that prevents moisture intrusion and water buildup. LP does not recommend LP SmartSide Panel for use in ICF and SIP assemblies. If used, LP will not warrant for Buckling and Shrinkage. However, balance of warranty does remain intact. DO NOT USE STAPLES SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR. Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering Keep siding clean and dry. Inspect prior to application. Precision 38 and 76 Series panel siding must be installed on 16 in. O.C. framing only. When installing on 24 in. O.C. framing, Precision Series 190 Series panel siding is required. In all installations over masonry or concrete walls, the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 in. O.C. The framing shall be of adequate thickness to accept 1-1/2 inches of nail penetration. A properly installed breathable water-resistant barrier is required between the siding and masonry or concrete walls. PRECISION 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH Moisture control and water vapor control are critical elements of proper housing design. Check your local building codes for application procedures for handling moisture and water vapor in your area. When using wet blown cellulose insulation, the insulation must not be in direct contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by the insulation manufacturer. As with all wood products, do not apply engineered wood siding to a structure having excessive moisture conditions such as drying concrete, plaster or wet blown cellulose insulation. If such conditions exist, the building should be well ventilated to allow it to dry prior to the application of the siding. Siding must not be applied to green or crooked structural framing members. Do not apply siding over rain -soaked or buckled sheathing materials. Gutters are recommended for control of roof water run off. A properly installed breathable water -resistive barrier is required behind the siding. Consult your local building code for details. LP will assume no responsibility for water penetration. Precision Series panel siding with SILVERTECH or SMARTFINISH does not require a secondary water-resistant barrier. Limited to sheds and other outdoor structures. Seal all gaps with a high -quality, non -hardening, paintable sealant. Follow the sealant manufacturer's instructions for application. Use a high -quality exterior sealant meeting the ASTM C920, minimum Class 2S sealant. All openings must be properly sealed or flashed in a manner that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages. Application instructions (cont.) Install kick -out flashing to direct the water into the gutter Install step flashing with minimum 4 in. upper leg Properly integrate flashing with the secondary water -resistive barrier. Use housewrap, flashing tape, z-flashing, or other items as needed to maintain the counterflashing principle. DO NOT extend the siding or trim into the kick -out flashing or gut- ter Maintain a clearance between the end of the gutter and the ad- joining wall to allow for proper maintenance of the siding Prime and paint ALL exposed cut edges i LP Siding Minimum 1" clearance between trim and roofing Clean rain gutter Do not run trim or siding inside of the kick out flashing Trim should be thick enough so the siding does not extend be- yond the face of the trim. Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup. LP® SmartSide° siding is not designed and/or manufactured to be used as trim or fascia. LP SmartSide trim and fascia are available in a variety of dimensions. DO Prime and paint all exposed surfaces including all drip edges or where water will hang. Apply finish coat as soon as possible or within 180 days of application. High -quality acrylic latex paint, specially formulated for use on wood and engineered wood substrates, is highly recommended. Semi -gloss or satin finish oil or alkyd paints are acceptable. For flat alkyd paint, please check with the coating manufacturer for their recommendations for use on composite wood siding. Follow the coating manufacturer's application and maintenance instructions. DO NOT USE Semi -transparent and transparent stains. Shake and shingle paints. Vinyl -based resin formulas such as vinyl acetate, PVA, vinyl acetate/acrylic copolymer paints. HANDLE PREFINISHED LP SMARTSIDE PRODUCTS WITH EXTREME CARE DURING STORAGE AND APPLICATION. TOUCH UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING APPLICATION PER PREFINISHERS SPECIFICATIONS. In braced wall assemblies, use minimum 6d (0.113 in. shank diameter, 0.270 head diameter), hot -dipped galvanized nails for 38 and 76 Series panels and minimum 8d (0.131 in. shank diameter, 0.290 head diameter) for 190 Series panels. Do not use electroplated fasteners. Refer to your local building code to verify the minimum allowable fastener size. Penetrate structural framing or wood structural panels and struc- tural framing a minimum of 1-1/2 in. For 38 Series panels, double nailing procedure meets wall bracing requirements and S/16 in. shear wall design values. 1 in. from edge Alignment bead 1/8 in. gap Figure 1 1 , 1 Double row of nails For 76 and 190 Series panels, single nailing meets wall bracing requirements. To meet the equivalent 3/8 in. shear wall design values, double nailing procedures must be used. It may be nec- essary to angle drive the second nail in order to penetrate the framing. Seal nails driven below the surface. 3/8 in. from edge Alignment bead 1/8 in, gap Nail penetration min. 1-1/2 in. Figure 2 t 1 Single row of nails Application instructions (cont.) Shearvalues for panels applied directly to studs shall be no greater than noted in Table 1 of the ICC-ES Report ESR-1301 or Table 1 of APA PR-N 124. Not warranted for application on SIP and ICF assemblies. CAUTION 38 and 76 Series panels must be installed on 16 in. O.C. framing only. When installing on 24 in. O.C. framing,190 Series panels are required. Backside of panel must not come in contact with masonry or concrete foundation. Do not force siding into place. Maintain the illustrated 1/8 in. space behind the joint to allow for expansion while the panel equilibrates with the local environment. LP° SmartSide° Panel siding must not be attached by stapling. DO NOT INSTALL OVER ALIGNMENT BEAD. Install panels in light contact to the edge of alignment bead. (see Figure 1 and Figure 2) Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. Where siding butts window trim, door casings and masonry, etc. leave a 3/16 in. gap and seal. CONDITION Snug Flush Visible fiber Countersunk'/,.- /e IN._ Countersunk more than'/a in. Insulated Sheathings I ''` LP SmartSide Sidings may be installed over low -compression rigid 4 in. min. vertical foam or exterior gypsum. The following precautions must be followed: flashing a) Adequate bracing of the wall in accordance with the International Codes or other ruling building code is required. b) For rigid foam sheathing up to 1" (25.4 mm) thick, siding may be nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be in- creased to ensure a minimum 1-1/2" (38.1 mm) fastener penetra- tion into the structural framing. c) For rigid foam sheathing greater than 1 in. (25.4 mm), a minimum 1-1/2 in. (38.1 mm) thick by 3-1/2 in. (88.9 mm) wide vertical strap- ping or furring strip must be installed over the sheathing to provide a solid, level nailing base for the siding. The strapping must be securely fastened to structural framing spaced no greater than 16 in. O.C. (406 mm) with a minimum nail penetration of 1-1/2 in. (38.1 mm) and a maximum nail spacing no greater than the width of the siding. Louisiana-Pacific will assume no responsibility for any damage or condition arising from the use of rigid foam or exterior gypsum. Nail 3/8 in. from edge 12 in. max. field nailing 6 in. max. K perimeter 6 in. max. ro a ". § `. nailing perimeter nailing Do not let panel V ''T 6 in. min. ground contact masonry clearance Foundation Figure 3 1 in. min. clearance from roofing CORRECTION OK OK Paint Apply sealant Apply sealant and re -nail Figure 4 m Prime and paint bottom drip edges HORIZONTAL WALL JOINTS BUTT & FLASH LAP VSiding Siding Blocking min.I ainghP 1 in. minedpaLpppaneloverlagwithoverbottom 4 in. vertical leg panel Figure SA Figure SB LAPPED HORIZONTAL WALL JOINT Siding Framing (band joist, truss chord, etc.) 1 in. min. Wall Framing overlap Figure SC HORIZONTAL BELTLINE JOINTS For multi -story buildings, make provisions at horizontal joints for setting" shrinkage of framing, especially when applying siding directly to studs. Siding (4 ft. x 8 ft.) BAND BOARD OVER PANEL FILLER Extend k siding s below sill plate\ Min. 1/8 in. or / flashing between siding and masonry. Figure 7A Interior Finish Space window/door per/ manufacturer's instruction Figure 6 Figure 9 AT „ .:a Scant face width 3/8 in. gap 1/8 in. gap Sloped flashing with 4 in. vertical leg SPACE JOINT 1/8 1N. f' 2 in. x 10 in. Refer to nailing instructions 1/g in. gapbandboard Filler Board Siding (4 ft. x 8 ft.) LP panel sidings are accepted by the State of California as category 8140- Exteriorwall siding and sheathing for Wildland Urban Interface WUI) applications. For WUI compliance, install LP panel sidings in accordance with Louisiana-Pacific's printed installation instructions with the addition of fire retardant seal (UL Listed fire caulk, nominal 1/4"bead) in the vertical joint and nailing pattern of 3" OC perimeter nailing/8" OC field nailing. Look for the California State Fire Marshal Office label on our siding. OR Sill plate Flashing i t Masonrl foundatit Figure 8 The Louisiana-Pacific Corporation ("LP") LP SmartSideSiding (the Products") limited warranty (the "Warranty") applies only to structures on which the Products have been applied, finished and maintained in accordance with the published application, finishing and maintenance instructions in effect at the time of application. The failure to follow such application, finishing or maintenance instructions will void the Warranty as to the portion of the Products affected by the variance (the 'Affected Products"). LP assumes no liabilityfor any loss or damage sustained bythe Affected Products and is expressly released by the purchaser or owner from any such loss or liability. Any modification of the Warranty's application, finishing or Figure 7B maintenance requirements is void and unenforceable unless approved in writing prior to application by the Siding General Manager or his designee and a member of the LP Legal Department. Siding Code Approved Breathable Water -Resistive Barrier 3/8 in. gap Sloped flashing with 4 in. vertical leg Trim Nail fin do not damage) For a copy of the warranty or for installation and technical support, visit the LP SmartSide product support Web site at: www.lpsmartside.com or for additional support call 800-4S0-6106. WARRANTY REMEDIES ARE NOT AVAILABLE IF REQUIREMENTS ARE NOT FOLLOWED. Cal. Prop 6S Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer. SMARTSIOE" TRIM 5 SIDING 02014 Louisiana-Pacific Corporation. All rights reserved. LP, SmartSide, SilverTech and SmartFinish are registered trademarks of Louisiana-Pacific Corporation. Printed in U.S.A. NOTE: Louisiana-Pacific Corporation periodically updates and revises its product information. To verify that this version is current, call 800-450-6106. LPZ80512 1114 Figure 10 6 in. ohni bottom course ide;tall Figure 10E 6 alternate inside corner details Gap 3/16 in. Gap 3/16 in. and seal 1 11 and seal — Shiplap Edge Panel panN joint Figure 100 Vapor Retarder if requiied byrode caulk Figure 10B Breathable water-resistant barrier 6 in. minimum ground clearance Figure 10C