HomeMy WebLinkAbout114 N Aberdeen Cir (4)Permit # : O's ' /V &3"6 Job -Address: / %q / �' &3" l/
Descriptlon-of Work: C f
�--�"IF
Historic District: Zonir
CITY OF SANFORD PERMIT APPLICATION
..Value of Work:
Date:
40 RFc
F��
G �I FO
?00S
Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool
Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial
Occupancy Type: Residential Commercial Industrial Total Square Footage:
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X)
Parcel #:
OwnersAName_& Address:
!q Al- A"
Contractor Name & Address:
Phone & Fax:
Bonding Company:
Address:
Mortgage Lender: .
Address:
Architect/Engineer:
Address:
C
Contact Person:
(Attach Proof of Ownership & Legal Description)
State License Number:
Phone:
Fax:
it
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
AcceptanceJ-o
ca
o that I will no the owner of he p operty of the requirements of Florida Lien Law, FS 713.
r�
Agent ate Signature of Contractor/Agent Date
Ia e; ( Print Contractor/Agent's Name
6S
SignA �%Notagrpf Date Signature of Notary -State of Florida Date
* My COMMISSION # DD 164280
NT EXPIRES: November 12, 2006
7 r.. t
Ownei/Agent is 90°deTYl}f!, Qwn 1Me o�
Produced ID b vl" X27 'b
APPLICATION APPROVED BY: Bldg Zoning:
(Initial & Date) (Initial & Date)
Special Conditions:
Contractor/Agent is Personally Known to Me or
_ Produced ID
Utilities:
FD:
(Initial & Date) (Initial & Date)
Owners of property when acting as their own contractor and providing direct, onsite supervision
themselves of all work not performed by licensed contractors, when building or improving farm
outbuildings or one -family or two-family residences on such property for the occupancy or use of such
owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to
exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or
lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such
structure by the owner -builder within 1 year after completion of same creates a presumption that the
construction was undertaken for purposes of sale or lease. This subsection does not exempt any person
who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The
owner may not delegate the owner's responsibility to directly supervise all work to any other person
unless that person is registered or certified under this part and the work being performed is within the
scope of that person's license. For the purposes of this subsection, the term "owners of property"
includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this
subsection, an owner must personally appear and sign the building permit application.
State law requires construction to be done by licensed contractors. You have applied for a permit under
an exemption to that law. The exemption allows you, as the owner of your property, to act as your own
contractor with certain restrictions even though you do not have a license. You must provide direct,
onsite supervision of the construction yourself. You may build or improve a one -family or two-family
residence or a farm outbuilding. You may also build or improve a commercial building, provided your
costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may
not be built or substantially improved for sale or lease. If you sell or lease a building you have built or
substantially improved yourself within 1 year after the construction is complete, the law will presume that
you built or substantially improved it for sale or lease, which is a violation of this exemption. You may
not hire an unlicensed person to act as your contractor or to supervise people working on your building. It
is your responsibility to make sure that people employed by you have licenses required by state law and
by county or municipal licensing ordinances. You may not delegate the responsibility for supervising
work to a licensed contractor who is not licensed to perform the work being done. Any person working
on your building who is not licensed must work under your direct supervision and must be employed by
you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation
for that employee, all as prescribed by law. Your construction must comply with all applicable laws,
ordinances, building codes, and zoning regulations.
_ , � � - 4 cc ^p�
I, _, do hereby state that I am qualified and capable of performing the
requested 94nstruction involved with the permit application filed.
I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work
allowed by law on the permitted structure.
19 le //
' :0 e wilder -Signature -- --D e
-� Punt Owner, uild&A4rpe
Signature of Notary -State of Florida Date
Owner is Personally Known to Me or has
Produced ID
Seminole County Property Appraiser Get Information by Parcel Number
DAvio JOHNSON. CFA. ASA
PROPERTY
APPRAISER
SEMINOLE COUNTY FL.
1101E. FIRST ST
SANFORD, FL 32771-1468
407-605-7506
GENERAL
TO
4. 1 BLOCK H 1
2005 WORKING VALUE SUMMARY
Parcel Id: 07-20-31-506-0000- Tax District: S1-SANFORD
0210
Owner: MANUEL ANTHONY Exemptions: 00-
L & YVONNE D HOMESTEAD
Address: 114 N ABERDEEN CIR
City,State,ZipCode: SANFORD FL 32773
Property Address: 114 ABERDEEN CIR N SANFORD 32773
Subdivision Name: BRYNHAVEN 1ST REPLAT
Dor: 01 -SINGLE FAMILY
Value Method:
Market
Number of Buildings:
1
Depreciated Bldg Value:
$76,218
Depreciated EXFT Value:
$384
Land Value (Market):
$19,500
Land Value Ag:
$0
Just/Market Value:
$96,102
Assessed Value (SOH):
$68,382
Exempt Value:
$25,000
Taxable Value:
$43,382
Tax Estimator
2004 VALUE SUMMARY
SALES Tax Value(without SOH): $1,185
2004 Tax Bill Amount: $848
Deed Date Book Page Amount Vac/Imp
Save Our Homes (SOH) Savings: $337
WARRANTY DEED 11/1990 02243 1286 $73,100 Improved
2004 Taxable Value: $41,390
Find Comparable Sales within this Subdivision
DOES NOT INCLUDE NON -AD VALOREM
ASSESSMENTS
LAND LEGAL DESCRIPTION PLAT
Land Assess Frontage Depth Land Unit Land LEG LOT 21 BRYNHAVEN 1 ST REPLAT PB
Method Units Price Value
39 PGS 20 & 21
LOT 0 0 1.000 19,500.00 $19,500
BUILDING INFORMATION
Bid Num Bid Type Year Bit Fixtures Base SF Gross SF Heated SF Ext Wall Bid Value Est. Cost New
1 SINGLE FAMILY 1990 6 1,167 1,677 1,167 CONIC BLOCK $76,218 $80,441
Appendage I Scift OPEN PORCH FINISHED / 48
Appendage I Sqft GARAGE FINISHED / 462
EXTRA FEATURE
Description Year Bit Units EXFT Value Est. Cost New
WOOD UTILITY BLDG 2000 80 $384 $480
NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad
valorem tax purposes.
k" If you recently purchased a homesteaded property your next year's property tax will be based on Just/Market value.
Page 1 of 1
http://www.scpafl.org/pls/web/re_web.seminole_county_title?parcel=07203150600000210&cpad=aberd&... 8/1/2005
r
' j..
APPROVED ARRANGEMENT.
wear �
Test Data Review Certificate 13026447A;
#3026447B; 13026447C and COP/rest
Report Validation Matra 13026447A-
001, 002, 003; 430264476-001, D02,
003;13026447C -M. 002, 003
0provides
o
additional information -
evadable from the ITS/WH websfte
(www.etisemko.com), the Masonite
websfte (www.niasordte.com) or the
Note: Masomite tedmical carrier.
Units of other sizes are covered by this
report as long as the panel used does not
exceed 37 x 8'0".
Single Door
Mmdrrarm wit size = 37 x Bb"
Ba
Design Pressure a RM
+40.0/-40.0
Limited water unless special threshold design is used.
Large Missile Impact Resistance
Hurricane protective system (shutters) is REQUIRED.
Actual design pressure and impact resistant requirements for a specific building design and geographic location Is determined by ASCE 7 -rational,
state or local building codes specify the edition required.
MINIMUM ASSEMBLY DETAIL:
Compliance requires that minimum assembly details have been followed — see MAD-WL-MA0001-02 and
_. MAD-WL-MA0041-02.
MINIMUM INSTALLATION DETAIL:
Compliance requires that minimum installation details have been followed — see MID-WL-MA0001-02.
APPROVED DOOR
DOOR STYLES: PLANS REVIE E
1/4 CITY ®F SANFOIRD
as
as
822 Series
1/2 GLASS:
4N Series 106 Series
June 17, M02
our emtimring pmgmm of pmducl ftrmnimt maks spec(vations. design ad product
ddaa su*dw ch-ge *I#- MUM-
APPROVED DOOR STYLES:
FULL GLASS:
810 Series 852 Series 300 Series
CERTIFIED TEST REPORTS:
CTLA-BO5W
Certifying Engineer and License Number: Ramesh Patel, REJ20224
Unit Tested in Accordance with Miami -Dade BCCO PA202.
Door panels constructed'from 0.075" minimum thick fiberglass skins. Both stiles constructed of 1-5/8"
laminated lumber. Top end rails constructed of 31/32" wood. Bottom end rails constructed of 31/32"
wood composite. Interior cavity of slab filled with rigid polyurethane foam core. Slab glazed with insulated
glass mounted in a rigid plastic tip lite surround.
Frame constructed of wood with an extruded aluminum threshold.
PRODUCT COMPLIANCE LABELING:
TESTED IN
ACCORDANCE WITH
MIAMI-DADE BCCO PA202
COMPANY NAME
CRY, STATE
To the best of my knowledge and ability the above side -hinged
exterior door unit conforms to the requirements of the 2001 Florida
Building Code, Chapter 17 (Structural Tests and Inspections).
State of Florida, Professional Engineer
Kurt Balthazor, P.E. — License Number 56533
,Mme 17, 2002-
dur continuing program of Product tmprdvdnent makes spedfieaWs, design and product
detetl subiert to dwW wOMmA notbe
Test Data Review Certificate 13026447A;
1302644713;130264470 and COP/Test
Report Validation Matra 13026447A-
OOt, 002,003; #3026447B-001, 002,
003;130264470-001, 002, 003
provides additional information -
available from the ITS/WH website
(www.etlsemko.com), the Masonite
website (www:masonite.cotn) Or the
Masonite technical center.